Transition Networks Switch CPSMC0800 100 User Manual

Transition Networks  
CPSMC08xx-100  
8-Slot PointSystem™ Chassis  
User’s Guide  
revision B  
CPSMC0800-100 AC-powered  
CPSMC0810-100 DC-powered  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystem™ Chassis  
Table of Contents  
1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
1.1  
1.2  
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Unpacking the CPSMC08xx-100 Equipment . . . . . . . . . . . . . . . . .5  
2
Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
2.1  
Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . .6  
2.1.1 Chassis Face Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2.1.2 Calculating Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
2.1.3 Installing Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . .7  
2.1.4 Replacing Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . .8  
2.2  
Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
2.2.1 Three Types of Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . .9  
2.2.2 Installing the Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
2.2.3 Replacing the Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . .11  
3
4
Powering the CPSMC08xx-100 . . . . . . . . . . . . . . . . . . . . . . .12  
3.1  
Primary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
3.1.1 AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
3.1.2 DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
3.2  
Auxiliary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
3.2.1 AC Auxiliary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
3.2.2 DC Auxiliary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15  
CPSMC08xx-100 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
4.1  
Installing the CPSMC08xx-100 Chassis . . . . . . . . . . . . . . . . . . . .16  
4.1.1 Table-Top Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
4.1.2 Standard 19-Inch Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
4.1.3 Grounding Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
4.2  
4.3  
4.4  
Cascade Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
Connecting the Slide-in-Modules to the Network . . . . . . . . . . . . .21  
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21  
5
6
Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22  
5.1  
Hardware Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22  
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
Contact Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystem™ Chassis  
1
Introduction  
1.1  
Description  
The Transition Networks PointSystem™ CPSMC08xx-100 is a 19-inch, rack-  
mountable chassis for selected Transition Networks media converter slide-in-  
modules. The chassis allows the network administrator to connect various copper  
and fiber-optic network media over protocols that include Ethernet, Fast Ethernet,  
DS3/E3, and OC-12. The chassis provides installation space for up to eight (8)  
single-slot or four (4) dual-slot media converter slide-in-modules in the front of the  
unit.  
Management Module Installed Slide-In-Module  
Open Slot  
Power Inlet  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
The CPSMC0800-100 comes equipped with an AC power supply. The CPSMC0810-  
100 comes equipped with a DC power supply. An optional, auxiliary AC or DC  
power supply with instant fail over operation is also available for either model. The  
primary power supply is accessed through the power inlet on the front panel, while  
auxiliary power is accessed through the auxiliary power inlet, located on the back  
panel.  
Grounding Lugs  
Auxiliary Power Inlet  
The CPSMC08xx-100 also comes equipped with a pair of grounding lugs for  
providing proper grounding of the chassis.  
Multiple fans help remove heat from the chassis.  
With installed PointSystem™ management module(s) (P/N CPSMM-120, -200, or  
-210), the CPSMC08xx-100 can be managed and monitored via:  
An SNMP application such as Transition Networks FocalPoint™ management  
software installed at a remote Network Management Station (NMS).  
A remote Web browser.  
A command-line interface (CLI) at an attached terminal.  
A command-line-interface (CLI) at a remote Telnet connection.  
The management modules also make it possible to control up to eight (8) cascaded  
chassis, fully-populated with installed media converter slide-in-modules.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystem™ Chassis  
1.2  
Unpacking the CPSMC08xx-100 Equipment  
Use the following list to verify the shipment:  
Item  
Part Number  
CPSMC0800-100  
CPSMC0810-100  
CPSFP-200  
8-Slot chassis with AC power supply  
8-Slot chassis with DC power supply  
PointSystem™ chassis face plates (5)  
Power Cord  
(varies by country)  
AI-7227  
FocalPoint™ Software Disk  
(included with the management modules)  
Users Guide  
33270  
The following items are optional accessories for the CPSMC08xx-100 8-slot  
PointSystem™ chassis.  
Item  
Part Number  
External AC Power Supply  
External DC Power Supply  
1-slot Master Management Module  
2-slot Master Management Module  
Expansion Management Module  
Management Module Cascade Connector  
23-inch Rack Mount Ears  
CPSMP-180 (optional)  
CPSMP-190 (optional)  
CPSMM-100 (optional)  
CPSMM-200 (optional)  
CPSMM-210 (optional)  
6026 (optional)  
CPSRE-238 (optional)  
Selectable Media Converter Slide-in-Module(s) (various P/N) - (optional)  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
2
Slide-in-Modules  
2.1  
Media Converter Slide-in-Modules  
Transition Networks media converter slide-in-modules, installed in slots at the front  
of the chassis, allow the network administrator to connect various copper and fiber-  
optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3,  
NOTE: Refer to the users guide that comes with each media converter slide-in-  
module for specific information on the modules cables, connectors, and LED  
indicators.  
2.1.1  
Chassis Face Plates  
CAUTION: Slots in the CPSMC08xx-100 chassis without a slide-in-module  
installed MUST have a protective chassis face plate (P/N CPSFP-200) covering the  
empty slot for Class A compliance.  
Install a chassis face plate over any unused chassis slot by aligning the hole in the  
face plate with the threaded hole in the chassis. Secure the face place with the  
enclosed bolt.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
CPSMC-0800  
8-Slot Chassis  
Chassis Face Plate  
2.1.2  
Calculating the Power Consumption  
CAUTION: Before installing the media converter slide-in-modules, refer to the  
power consumption data for each individual media converter (provided in the  
Users Guide shipped with each media converter). The combined power  
consumption of all devices must not exceed the available power supply. Failure to  
observe this caution could result in diminishing system reliability.  
In other words, the combined wattage of the CPSMC08xx-100 chassis plus all slide-  
in-modules must be less than the available power.  
Contact Transition Networks Tech Support to ensure the power requirements for  
your specific application do not exceed the available power.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
2.1.3  
Installing the Media Converter Slide-in-Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge  
precautions when installing the media converter slide-in-module(s) into the chassis.  
Failure to observe this caution could result in damage to, and subsequent failure  
of, the media converter slide-in-module(s).  
NOTE: The media converter slide-in-modules can be installed in any installation  
slot, in any order.  
To install the media converter slide-in-module into the CPSMC08xx-100 chassis:  
1. Remove the protective plate from the installation slot by removing the one (1)  
screw that secures the plate to the front of the chassis.  
NOTE: If the slide-in-module requires two slots, remove the protective plates  
from two (2) adjacent installation slots.  
2. Align the slide-in-module with the chassis installation slot so that the panel  
fastener screw is at the left of the slide-in-module.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
10/100SX  
CPSMC-0800  
10/100TX  
8-Slot Chassis  
Multimode  
Singlemode  
Panel Fastener Screw  
3. Carefully slide the slide-in-module into the installation slot, while aligning the  
modules circuit board with the installation guides.  
NOTE: Ensure that the slide-in-module is firmly seated inside the chassis.  
4. Push in and rotate the attached panel fastener screw clockwise to secure the  
slide-in-module to the chassis.  
5. Repeat steps 1 through 4 for additional slide-in-module(s).  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
2.2.4  
Replacing the Media Converter Slide-in-Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge  
precautions when replacing media converter slide-in-module(s). Failure to observe  
this caution could result in damage to, and subsequent failure of, the media  
converter slide-in-module(s).  
NOTE: The media converter slide-in-modules can be hot-swapped.  
To replace a media converter slide-in-module:  
1. Remove the slide-in-module to be replaced by loosening the panel fastener  
screw that secures the module to the chassis front. Slide the module from the  
chassis.  
2. Align the replacement slide-in-module with the chassis installation slot so that  
the panel fastener screw is to the left.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
10/100SX  
CPSMC-0800  
10/100TX  
8-Slot Chassis  
Multimode  
Singlemode  
Panel Fastener Screw  
3. Carefully slide the replacement slide-in-module into the installation slot, while  
aligning the modules circuit board with the installation guides.  
NOTE: Ensure that the slide-in-module is firmly seated inside the chassis.  
4. Push in and rotate the attached panel fastener screw clockwise to secure the  
slide-in-module to the chassis.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
2.2  
Management Modules  
Optional network management is provided by SNMP software embedded in  
Transition Networks PointSystemmanagement module(s) that can be installed in  
the CPSMC08xx-100 chassis.  
Transition Networks provides two such modules:  
CPSMM-120 Single-Slot Master Management Module.  
CPSMM-200 Dual-Slot Master Management Module.  
Along with an additional expansion module:  
CPSMM-210 Single Slot Expansion Management Module  
2.2.1  
Three Types of Management Modules  
CPSMM-120 Single-Slot Master Management Module  
TX PWR  
RX LNK  
RESET  
The optional CPSMM-120 Single-Slot Master Management Module can  
be installed to enable network management of a single CPSMC08xx-  
100 chassis .  
Refer to the CPSMM-120 users guide for more information on the  
CPSMM-120 Single-Slot Master Management Module.  
CPSMM120  
CPSMM-200 Dual-Slot Master Management Module  
The optional CPSMM-200 Dual-Slot Master Management  
Module can also be installed in the CPSMC08xx-100 chassis to  
enable network management.  
TX PWR  
RX LNK  
RESET  
This module has all of the features of the CPSMM-120 plus a pair  
of cascade ports, which allow multiple PointSystemchassis to  
be connected.  
Note also that this module requires two adjacent slots in the  
CPSMC08xx-100 chassis for installation.  
CPSMM200  
Refer to the CPSMM-200/-210 users guide for more information  
on the CPSMM-200 Dual-Slot Master Management Module.  
CPSMM-210 Single-Slot Expansion Management Module  
The CPSMM-210 is used with the CPSMM-200 to connect up to eight (8)  
PointSystem™chassis into one manageable stack.  
RESET  
Refer to the CPSMM-200/-210 users guide for more information on the  
CPSMM-210 Single-Slot Expansion Management Module.  
Power  
See section 4.3 Cascade Option for details on connecting multiple  
CPSMC08xx-100 chassis.  
CPSMM210  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
2.2.2  
Installing the Management Modules  
CAUTION:  
Wear a grounding device and observe electrostatic discharge  
precautions when installing the management module(s) in the CPSMC08xx-100  
chassis. Failure to observe this caution could result in damage to, and subsequent  
failure of, the management module.  
NOTE: Transition Networks recommends installing the management module into  
the left-most installation slots to keep the management cables separate from the  
media converter cables.  
To install a management module into the CPSMC08xx-100 chassis:  
1a. CPSMM-200 Dual-Slot Master Management Module:  
If chassis face plates are covering the installation slots, remove two (2)  
management module protective plates from the two (2) installation slots at the  
far-left position of the chassis.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
DB-9  
CPSMC-0800  
8-Slot Chassis  
Panel Fastener Screw  
1b. CPSMM-120 Single-Slot Master Management Module OR  
CPSMM-210 Single-Slot Expansion Management Module:  
If chassis face plates are covering the installation slots, remove one (1)  
management module protective plate from one (1) installation slot at the far-left  
position of the chassis.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
DB-9  
CPSMC-0800  
8-Slot Chassis  
Panel Fastener Screw  
2. Align the management module with the PointSystem™ chassis installation slot  
so that the panel fastener screw is to the left of the module.  
3. Carefully slide the management module into the installation slot, while aligning  
the modules circuit board with the installation guides.  
NOTE: Ensure that management module is firmly seated inside the chassis.  
4. e the attached panel fastener screw clockwise to secure the module to the  
chassis.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
2.2.3  
Replacing the Management Modules  
CAUTION: Wear a grounding device and observe electrostatic discharge  
precautions when replacing media converter slide-in-module(s). Failure to observe  
this caution could result in damage to, and subsequent failure of, the management  
module(s).  
NOTE: The management modules can be replaced while the chassis remains  
powered. However, you must configure a new IP address for the replacement  
management module. For more information, see the FocalPoint™ 2.0 users guide  
To replace a management module in the CPSMC08xx-100 chassis:  
1. Remove the management module to be replaced by loosening the panel  
fastener screw that secures the module to the chassis front. Slide the module  
from the chassis.  
2. Align the replacement module with the installation slot so that the panel  
fastener screw to the left of the module..  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
DB-9  
CPSMC-0800  
8-Slot Chassis  
Panel Fastener Screw  
3. Carefully slide the replacement management module into the installation slot,  
while aligning the module’s circuit board with the installation guides.  
NOTE: Ensure that the management module is firmly seated inside the chassis.  
4. Push in and rotate the attached panel fastener screw clockwise to secure the  
management module to the chassis.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
3
Powering the CPSMC08xx-100  
The CPSMC08xx-100 chassis can be powered through an AC or DC power supply.  
An optional auxiliary power supply, with instant fail over protection, is also  
available.  
NOTE: The CPSMC08xx-100 chassis does not have an ON/OFF switch.  
Power up the chassis by connecting the power supply.  
Power-down the chassis by disconnecting power supply.  
NOTE: Contact Technical Support for any questions concerning power supply.  
3.1  
Primary Power Supply  
3.1.1  
AC Power Supply  
The CPSMC0800-100 includes an internal AC power supply, which is accessed  
through a power inlet on the front panel. The power cord is included.  
Power Inlet  
Mpls, MN 55344  
put Power:  
0-240 VAC  
6A max. (60W max)  
0/60 Hz  
CPSMC-0800  
-Slot Chassis  
Power Cord  
To power the CPSMM0800-100 chassis through the primary AC power supply:  
1. Connect the female end of the power cord to the power inlet on the front panel  
of the chassis.  
2. Plug the male end of the power cord into the correct voltage rack or wall socket.  
3. Verify that the chassis is powered by observing the illuminated power LEDs on  
the installed slide-in-modules and by the chassis’ fan operation.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
3.1.2  
DC Power Supply  
This product is intended to be used in a restricted access location. Proper earthing  
(grounding) is required to ensure safe operation. Grounding terminals are provided  
(section 4.1.3) for proper grounding of the device as per customer installation  
requirements and local electrical codes.  
Prior to installation, use a  
voltmeter/ohmmeter to check the wiring for the presence of earth ground.  
A readily accessible disconnect device as part of the building installation shall be  
incorporated into the fixed wiring. The disconnect device (a 48 VDC, 15 or 20A  
circuit breaker or switch) must be included in the ungrounded supply conductor.  
Overcurrent protection must be a 48 VDC, 15 or 20A fuse or circuit breaker.  
Read and follow all warning notices & instructions marked on the product or  
included in the manual.  
CAUTION: All installation and service must be performed by qualified service  
personnel.  
The CPSMC0810-100 includes an internal DC power supply, which is accessed  
through the power terminal block on the front panel.  
Power Terminal Block  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
CPSMC-0800  
8-Slot Chassis  
GND  
+
To power the CPSMM0810-100 chassis through the primary DC power supply:  
1. Connect the +48-VDC terminal to the power terminal block connector marked  
“+”. Turn the terminal screw clockwise to secure.  
2. Connect the -48-VDC terminal to the power terminal block connector marked  
“-”. Turn the terminal screw clockwise to secure.  
3. Connect the ground terminal to the power terminal block connector marked  
“chassis ground”. Turn the terminal screw clockwise to secure.  
4. Verify that chassis is powered by observing the illuminated power LEDs on the  
installed slide-in-modules and by the chassis’ fan operation.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
3.2  
Auxiliary Power Supply  
The CPSMC08xx-100 chassis can also be supplied with auxiliary power from an  
external power converter, which is connected to the chassis through the auxiliary  
power inlet, located on the back panel. (Both and AC and a DC external power  
converter are available from Transition Networks.)  
Instant Fail Over Protection  
The CPSMC08xx-100 has instant fail over protection when both the primary and  
auxiliary power supplies are connected to external power sources. The auxiliary  
power supply waits in stand-by -- ready to supply power to the chassis in the event  
of power failure from the primary power supply  
AC and DC Power Supplies  
The CPSMC0800-100, with the internal AC power supply, can have either the AC-  
powered CPSMP-180 or the DC-powered CPSMP-190 as the Auxiliary power  
supply.  
Likewise, the CPSMC0810-100, with the internal DC power supply, can have either  
the AC-powered CPSMP-180 or the DC-powered CPSMP-190 as the Auxiliary  
power supply.  
3.2.1  
AC Auxiliary Power Supply  
To power the CPSMC08xx-100 chassis through the AC auxiliary power supply:  
1. Connect the female end of the external power converter to the auxiliary power  
inlet on the back of the chassis.  
2. Connect the female end of the power cord to the male end of the external  
power converter.  
3. Plug the male end of the power cord into the correct voltage AC rack or wall  
socket.  
4. Verify that Auxiliary power supply is connected properly by disconnecting the  
primary power supply, and then by observing the illuminated power LEDs on  
the installed slide-in-modules and by the chassis’ fan operation.  
Auxiliary Power Inlet  
External Power  
Converter  
Power Cord  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
3.2.2  
DC Auxiliary Power Supply  
This product is intended to be used in a restricted access location. Proper earthing  
(grounding) is required to ensure safe operation. Grounding terminals are provided  
(section 4.1.3) for proper grounding of the device as per customer installation  
requirements and local electrical codes.  
Prior to installation, use a  
voltmeter/ohmmeter to check the wiring for the presence of earth ground.  
A readily accessible disconnect device as part of the building installation shall be  
incorporated into the fixed wiring. The disconnect device (a 48 VDC, 15 or 20A  
circuit breaker or switch) must be included in the ungrounded supply conductor.  
Overcurrent protection must be a 48 VDC, 15 or 20A fuse or circuit breaker.  
Read and follow all warning notices & instructions marked on the product or  
included in the manual.  
CAUTION: All installation and service must be performed by qualified service  
personnel.  
To power the CPSMC08xx-100 chassis through the DC auxiliary power supply:  
1. Connect the female end of the external power converter to the auxiliary power  
inlet on the back of the chassis.  
2. Connect the +48-VDC terminal to the connector marked “+”. Turn the terminal  
screw clockwise to secure.  
3. Connect the -48-VDC terminal to the connector marked “-”. Turn the terminal  
screw clockwise to secure.  
4. Connect the ground terminal to the connector marked “chassis ground”. Turn  
the terminal screw clockwise to secure.  
5. Verify that Auxiliary power supply is connected properly by disconnecting the  
primary power supply, and then by observing the illuminated power LEDs on  
the installed slide-in-modules and by the chassis’ fan operation.  
Auxiliary Power Inlet  
External Power  
Converter  
GND  
+
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
4
CPSMC08xx-100 Chassis  
4.1  
Installing the CPSMC08xx-100 Chassis  
The CPSMC08xx-100 can be installed in a standard 19-inch rack or on a table, shelf,  
or other stable surface.  
CAUTION: Install the chassis so that the air flow around it is not restricted.  
4.1.1  
4.1.2  
Table-Top Installation  
The CPSMC08xx-100 chassis is shipped with nine (9) rubber feet for optional  
installation on a table or other flat, stable surface in a well-ventilated area. If table-  
top installation is desired, remove the rubber feet from the card and place them on  
the bottom of the chassis. Distribute the feet so that the chassis is level when placed  
upright.  
Standard 19-inch Rack Installation  
The maximum recommended ambient temperature (Tmra) for the CPSMC08xx-100  
chassis is 40°C. If the chassis is installed in a closed or multi-unit rack assembly,  
the operating ambient temperature of the the rack environment may be greater  
than room ambient.  
NOTE: Rack-mounted equipment must be reliably grounded. Power supply  
connections other than direct connection to the branch circuit (e.g., use of power  
strips) should be employed.  
Recessed Alignment  
at front  
Flush Alignment  
at front  
Flush Alignment  
at back  
Recessed Alignment  
at back  
The CPSMC08xx-100 chassis is designed so that the installation brackets can be  
installed to align the chassis either flush against the front or back edge of the rack  
or recessed from the front or back edge of the rack.  
WARNING: Select mounting bracket locations on the chassis that will keep the chassis balanced when  
mounted in the rack. Failure to observe this warning could allow the chassis to fall, resulting in  
equipment damage and/or possible injury to personnel.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
To install the CPSMC08xx-100 chassis into a standard 19-inch rack:  
1. Determine the preferred alignment of the chassis in the rack.  
NOTE: Installation bracket mounting screws are provided. Rack mount screws  
and clip nuts are NOT provided.  
2. Locate six (6) installation bracket mounting screws (provided) for each chassis  
to be installed.  
WARNING: Mount the chassis evenly and securely onto the rack. Failure to  
observe this warning could allow the chassis to fall, resulting in equipment  
damage and/or possible injury to personnel.  
3. Align the universal mounting bracket in the selected position against the side of  
the chassis so that the chassis installation holes are visible through the universal  
bracket installation holes.  
4. Using a Phillips screwdriver, install the three (3) screws through the mounting  
bracket into the installation holes on side of the chassis.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
CPSMC-0800  
8-Slot Chassis  
5. Repeat steps 3 and 4 for the second mounting bracket.  
6. Locate four (4) screws (not provided) and optional clip-nuts (not provided) for  
each chassis to be installed.  
7. Carefully align the chassis at a secure and level position between the 19-inch  
site rack mounting rails.  
8. Install two (2) screws through the right bracket into the right mounting rail and  
two (2) screws through the left bracket into the left mounting rail, using the clip  
nuts to secure, if necessary.  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
CPSMC-0800  
8-Slot Chassis  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
4.1.3  
Grounding Lugs  
The CPSMC08xx-100 comes equipped with grounding lugs, which are provided for  
a grounding conductor wire terminated with a two-hole, compression-type,  
grounding connector. The grounding wire -- which must be a copper conductor --  
is not included with the chassis and must be provided by the customer/installer.  
The electrical conducting path from the chassis must:  
Flow via the grounding lugs to the Common Bonding Network (CBN) for  
telecom installations; or to an alternate approved grounding system (if required)  
for non-telecom installations,  
Be of sufficiently low impedance to conduct fault currents likely to be imposed  
on the chassis, and  
Enable proper operation of any over-current protection devices.  
The two-hole, compression-type, grounding connector must be fastened to the  
grounding lugs with the enclosed, anti-rotation star-washers and lug-nut fasteners.  
The required torque to the fasteners is specified by the connector’s manufacturer.  
Grounding lugs  
(6-32, 1/8" diam.)  
Two-hole, compression-type  
grounding connector (not included)  
3/4-inch  
spacing  
Star washer (included)  
Lug nuts (included)  
12 AWG copper wire  
(not included)  
To properly ground the CPSMC08xx-100 chassis:  
1. Obtain one (1) properly-terminated, grounding conductor (12 AWG copper  
wire gauge or larger) with a two-hole, compression-type, grounding connector.  
Note the manufacturer's applied torque that is required for the connector.  
2. Attach the grounding conductor to the chassis by placing the two-hole,  
compression-type connector onto the grounding lugs and fasten with  
appropriate lock-washers and lug-nuts at the proper torque.  
3. Attach the opposite end of the properly-terminated grounding conductor to the  
Common Bonding Network (CBN) for telecom installations, or to an approved  
grounding system (if required) for non-telecom installations.  
Grounding Lugs  
Grounding Wire with a  
two-hole, compression-type  
grounding connector  
CBN (for telecom installation)  
or Earth Ground  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
4.2  
Cascade Option  
The management module cascade option allows the network administrator to  
connect up to eight (8) CPSMC08xx-100 chassis into one manageable stack,  
providing a single management source for up to 55 installed media converter  
devices.  
To create the cascade option, the CPSMM-200 Dual Slot Master Management  
Module is installed in the first chassis in the series. The CPSMM-210 Single-Slot  
Expansion Management Module is installed in each subsequent chassis.  
The CPSMM-200  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
management module is  
installed in the first  
chassis in the series  
1.6A max. (60W max)  
50/60 Hz  
TERM  
INIT 12C  
12C-1  
INPORT  
OU
CPSMC-0800  
10BASE-T  
8-Slot Chassis  
The CPSMM-210  
management module is  
installed in each  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
subsequent chassis  
CPSMC-0800  
8-Slot Chassis  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
CPSMC-0800  
8-Slot Chassis  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
CPSMC-0800  
8-Slot Chassis  
An alternative setup involves installing two CPSMM-200 Dual-Slot Master  
Management Modules into two adjacent chassis chassis for redundant management.  
The CPSMM-200  
management module is  
installed in the first  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
TERM  
INIT 12C  
12C-1  
INPORT  
OUTPORT  
CPSMC-0800  
10BASE-T  
8-Slot Chassis  
chassis in the series  
Another CPSMM-200  
managment module is  
installed in the next  
chassis as a backup  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
1.6A max. (60W max)  
50/60 Hz  
TERM  
INIT 12C  
12C-1  
INPORT  
OUTPORT  
CPSMC-0800  
10BASE-T  
8-Slot Chassis  
In this set-up, the two CPSMM-200 management modules auto-negotiate so that  
one module is in stand-by mode. If the primary management module fails, the  
stand-by module automatically takes over and manages the network.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
To cascade two or more CPSMC08xx-100 chassis:  
1. Locate one (1) Transition Networks management module cascade cable (with  
RJ-45 connectors installed at both ends) (P/N 6026) for each set of two (2)  
chassis to be cascaded.  
NOTE: Transition Networks management module cascade cables are one (1)  
meter long. Ensure that the chassis are installed within one (1) meter of each  
other.  
2. At the first chassis in the series: Plug the RJ-45 connector at one end of the  
cascade cable into the management modules RJ-45 port labeled “OUT”.  
3. At the next chassis in the series: Plug the RJ-45 connector at the other end of  
the cascade cable into the management modules RJ-45 port labeled “IN”.  
4. At the same chassis as in step 3: Plug the RJ-45 connector at one end of the  
cascade cable into the management modules RJ-45 port labeled “OUT”.  
5. At the next chassis in the series: Plug the RJ-45 connector at the other end of  
the cascade cable into the management modules RJ-45 port labeled “IN”.  
6. Repeat steps 4 and 5 until all chassis have been connected.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
4.3  
Connecting the Slide-in-Modules to the Network  
Once the CPSMC08xx-100 chassis has been installed, the media converter slide-in-  
modules may be connected to the network.  
CAUTION: Connect input/output network cables ONLY to media converter slide-  
in-module connectors within the same network protocol (such as Ethernet-to-  
Ethernet, Fast Ethernet-to-Fast Ethernet, ATM-to-ATM). Failure to observe this  
caution will cause data transfer to fail.  
Refer to the users guides included with the media converter slide-in-modules for  
cabling specifications and instructions.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
Multimode  
Singlemode  
10/100SX  
CPSMC-0800  
10/100TX  
8-Slot Chassis  
Check the individual user's guides for specific information on  
how to connect each slide-in-module to the network.  
4.4  
Operation  
Daily operation of the CPSMC08xx-100 chassis requires no network administrator  
activity except for the occasional monitoring of the status LED indicators on the  
installed media converter slide-in-modules.  
Each media converter slide-in-module and each management module has one or  
more LED indicators to help monitor the network.  
Refer to the users guide included with each management module and slide-in-  
module to interpret the LED indicators on the modules.  
LED indicators on the management module and slide-in-modules  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
TERM  
INIT 12C  
12C-1  
Multimode  
Singlemode  
INPORT  
OUTPORT  
10/100SX  
CPSMC-0800  
10BASE-T  
10/100TX  
8-Slot Chassis  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
5
Network Management  
The CPSMM100 firmware and the FocalPoint™ application are described in the  
FocalPoint™ 2.0 Management Application and CPSMM100 Firmware users guide  
(P/N 33293). This manual is included on the application CD and is also available  
Transition Networks CPSMM100 firmware is embedded in the optional  
management modules (see section 2.2). The firmware allows the network  
administrator to configure and manage the CPSMC08xx-100 chassis from an  
attached terminal or from a remote, networked computer.  
The firmware includes the Transition Networks Command Line Interface (CLI), a  
telnet server, a Web browser, and an SNMP (Simple Network Management  
Protocol) agent.  
In addition, Transition Networks FocalPoint™ application can be installed in the  
networked computer to provide a graphical user interface to monitor the  
PointSystem™ chassis.  
5.1  
Hardware Connections  
Network management can be accessed either through the DB-9 serial port or  
through the RJ-45 Ethernet port of the management modules.  
CPSMM-120  
1BASE-T  
SEIAL  
RJ-45 Ethernet Port  
DB-9 Serial Port  
DB-9  
IN  
OUT  
10BASE-T  
CPSMM-200  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
DB-9 Serial Port  
The DB-9 serial port allows the network administrator to configure and manage the  
CPSMC08xx-100 chassis using the SNMP Command-Line Interface (CLI) at an  
attached terminal or terminal emulator.  
Use a null modem cable to attach a terminal to the DB-9 serial port on the  
management module as shown.  
Attached terminal or terminal emulator  
connected to the DB-9 serial port  
via null modem cable.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
Multimode  
Singlemode  
10/100SX  
CPSMC-0800  
10/100TX  
8-Slot Chassis  
RJ-45 Ethernet Port  
The RJ-45 Ethernet port allows the network administrator to manage the  
CPSMC08xx-100 chassis via a remote Network Management Station (NMS) in one  
of two ways:  
1. Using the Transition Networks FocalPoint™ graphical user interface.  
2. Using a remote Telnet connection.  
Use an RJ-45 network cable to attach a terminal (via a network hub or switch) to the  
RJ-45 Ethernet port on the management module as shown.  
DB-9  
Mpls, MN 55344  
Input Power:  
110-240 VAC  
Multimode  
Singlemode  
1.6A max. (60W max)  
50/60 Hz  
10/100SX  
10/100TX  
Multimode  
Singlemode  
10/100SX  
CPSMC-0800  
10/100TX  
8-Slot Chassis  
Remote Telnet connection OR  
Remote NMS with an SNMP application  
Network hub or switch connected  
to the RJ-45 Ethernet port.  
NOTE: To manage the PointSystem™ chassis via a remote NMS, both the RJ-45  
Ethernet port and the NMS must be connected to a network with Internet access.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
6
Troubleshooting  
1. Are ANY of the POWER LEDs on any of the slide-in-modules illuminated;  
AND/OR are the fans operating?  
YES  
The chassis is receiving power. Proceed to the next step.  
NO  
Ensure all power supply cables for proper connection.  
Ensure the AC receptacle on the wall is supplying power.  
If the fuse for the AC receptacle on the wall blows repeatedly, have the AC  
receptacle inspected by a qualified electrician.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
2. Are ANY of the POWER LEDs on any of the slide-in-modules illuminated; but  
are the fans NOT operating?  
YES  
The chassis is receiving power. Proceed to the next step.  
NO  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
3. For the management modules (CPSMM120, CPSMM200, CPSMM210), are  
ANY of the POWER LEDs NOT illuminated?  
NO  
All management modules are receiving power. Proceed to the next step.  
YES  
For those management modules where the POWER LED is NOT illuminated:  
Ensure the management module is firmly seated in the slot.  
Press the RESET button on the management module.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
4. For the remaining slide-in-modules, are ANY of the POWER LEDs NOT  
illuminated?  
NO  
All slide-in-modules are receiving power. Proceed to the next step.  
YES  
For those slide-in-modules where the POWER LED is NOT illuminated:  
Ensure the slide-in-module is firmly seated in the slot.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.  
4. To determine if a fault is due to a software problem, consult the  
troubleshooting section of the FocalPoint™ 2.0 Management Application and  
CPSMM100 Firmware User’s Guide (P/N 33293). This manual is available on  
5. To determine if a fault is due to an individual or slide-in-module, consult the  
troubleshooting section of the user’s guide for that particular module.  
6. If none of the solutions listed in this section resolves the problem, contact  
Technical Support: U.S./Canada: 1-800-260-1312, International: 00-1-952-  
941-7600.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
Technical Specifications  
For use with Transition Networks Model CPSMC08xx-100 or equivalent.  
Dimensions  
17 x 10.4 x 1.8 inches (432 x 264 x 46 mm)  
8 lbs. (3.6 kg)  
Shipping Weight  
AC Power Supply  
Power Input:  
100-240 V, 50/60 Hz, 0.66-1.6 Amp (typical with a fully-loaded chassis)  
+12 VDC at 5 Amp maximum.  
Power Output:  
DC Power Supply  
Power Input:  
48-VDC (38 to 58 VDC) @ 1.6 Amp (typical with a fully-loaded chassis)  
+12 VDC at 8.3 Amp maximum.  
Power Output:  
MTBF (Mean Time Before Failure)  
without fans  
MIL217F2 V5.0 (hrs) Bellcore7 V5.0 (hrs)  
43,277  
22,972  
114,896  
61,715  
with three (3) fans  
Environment  
Tmra:  
0 to 40°C (32° to 104°F ) (Manufacturers rated ambient temperature)  
-40 to 80°C (-40 to 176°F )  
5 to 95%, non condensing  
Storage Temperature:  
Humidity:  
Altitude:  
0 to 10,000 feet  
Compliance  
Warranty  
EN 55022 Class A; EN 55024; FCC Class A; CE Mark  
Lifetime  
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the  
date of manufacture.  
The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC-825/CDRH  
standards and complies with 21 CFR1040.10 and 21CFR1040.11.  
CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or View Directly  
With Optical Instruments.  
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein  
may result in hazardous radiation exposure.  
Declaration of Conformity  
Name of Mfg:  
Transition Networks  
6475 City West Parkway, Minneapolis MN 55344 USA  
Model:  
8-Slot PointSystemChassis  
CPSMC0800-100, CPSMC0810-100  
EMC Directive 89/336/EEC  
Part Number:  
Regulation:  
Purpose: To declare that the 8-Slot PointSystemChassis to which this declaration  
refers is in conformity with the following standards.  
EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; 21 CFR subpart J  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive(s) and Standard(s).  
_April 1, 2003_____  
Stephen Anderson, Vice-President of Engineering  
Date  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
Cable Specifications  
Null Modem Cable  
The Null Modem Cable is used for connecting a terminal or terminal emulator to  
the management modules DB-9 connector to access the command-line interface.  
The table below shows the pin assignments for the DB9 cable.  
Function  
Mnemonic  
CD  
RXD  
TXD  
DTR  
GND  
DSR  
Pin  
1
2
3
4
5
6
7
8
Carrier Detect  
Receive Data  
Transmit Data  
Data Terminal Ready  
Signal Ground  
Data Set Ready  
Request To Send  
Clear To Send  
RTS  
CTS  
RJ-45 Cable  
Category 5:  
Gauge:  
24 to 22 AWG  
Attenuation:  
Maximum Cable Distance:  
22.0 dB /100m @ 100 MHz  
100 meters  
• Straight-through OR crossover cable may be used.  
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used.  
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a Gigabit Ethernet network.  
• Use only dedicated wire pairs for the active pins:  
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)  
• Do not use flat or silver satin wire.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
COAX Cable  
Coaxial cable media is used for circuits such as DS3, E1 and 10Base-2 Ethernet. The  
impedance of the coaxial cable is determined by the interface type, for example:  
75 ohm for DS3.  
50 ohm for 10Base-2 Ethernet.  
Special attention should be given to the grounding requirements of coaxial cable  
circuits. Installation may require grounding at both cable ends or only one cable  
end or neither cable end.  
Cable Shield Grounding  
Media converter network cabling my be shielded or unshielded. Shielded cables  
MUST be grounded according to the specific requirements of the media and port  
type. For example:  
Shielded RJ-45 cable used for 100Base-Tx Ethernet MUST be grounded at both  
cable endpoints via shielded RJ-45 jacks.  
Shielded RS-232 cable MUST have the shield grounded at both cable endpoints  
via shielded RS-232 connectors.  
COAX cable used for 10Base-2 Ethernet MUST only be grounded at a single  
point.  
The media converters provide a jumper option or other grounding mechanism as  
required. Special attention should be given to the grounding requirements of  
coaxial cable circuits. Installation may require grounding at both cable ends or only  
one cable end or neither cable end. See the individual media converter user’s guide  
for cable/port grounding requirements.  
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
Contact Us  
Technical Support  
Technical support is available 24 hours a day.  
United States: 1-800-260-1312  
International: 00-1-952-941-7600  
Transition Now  
Chat live via the Web with a Transition Networks Technical Support Specialist.  
Log onto www.transition.com and click the Transition Now link.  
Web-Based Seminars  
Transition Networks provides 12-16 seminars per month via live web-based training.  
Log onto www.transition.com and click the Learning Center link.  
E-Mail  
Ask a question anytime by sending an e-mail message to our technical support staff.  
Address  
Transition Networks  
6475 City West Parkway  
Minneapolis, MN 55344, USA  
telephone: 952-941-7600  
toll free:  
fax:  
800-526-9267  
952-941-2322  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
Warranty  
Limited Lifetime Warranty  
Effective for products shipped May 1, 1999 and after. Every Transition Networks'  
labeled product purchased after May 1, 1999 will be free from defects in material  
and workmanship for its lifetime. This warranty covers the original user only and is  
not transferable.  
This warranty does not cover damage from accident, acts of God, neglect,  
contamination, misuse or abnormal conditions of operation or handling, including  
over-voltage failures caused by use outside of the product's specified rating, or  
normal wear and tear of mechanical components. If the user is unsure about the  
proper means of installing or using the equipment, contact Transition Networks' free  
technical support services.  
To establish original ownership and provide date of purchase, please complete and  
return the registration card accompanying the product or register the product on-  
line on our product registration page.  
Transition Networks will, at its option:  
Repair the defective product to functional specification at no charge,  
Replace the product with an equivalent functional product, or  
Refund the purchase price of a defective product.  
To return a defective product for warranty coverage, contact Transition Networks'  
technical support department for a return authorization number. Transition's  
technical support department can be reached through any of the following means:  
Technical Support is available 24 hours a day via:  
phone 800-260-1312 x 200 or 952-941-7600 x 200  
fax 952-941-2322  
live web chat: Transition Now  
voice mail 800-260-1312 x 579 or 952-941-7600 x 579  
All messages will be answered within one hour.  
Send the defective product postage and insurance prepaid to the following address:  
CSI Material Management Center  
c/o Transition Networks  
508 Industrial Drive  
Waconia, MN 55387 USA  
Attn: RETURNS DEPT: CRA/RMA # ___________  
Failure to properly protect the product during shipping may void this warranty. The  
return authorization number must be written on the outside of the carton to ensure  
its acceptance. We cannot accept delivery of any equipment that is sent to us  
without a CRA or RMA number.  
The customer must pay for the non-compliant product(s) return transportation costs  
to Transition Networks for evaluation of said product(s) for repair or replacement.  
Transition Networks will pay for the shipping of the repaired or replaced in-warranty  
product(s) back to the customer (any and all customs charges, tariffs, or/and taxes  
are the customer's responsibility).  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMC08xx-100 PointSystemChassis  
Before making any non-warranty repair, Transition Networks requires a $200.00  
charge plus actual shipping costs to and from the customer. If the repair is greater  
than $200.00, an estimate is issued to the customer for authorization of repair. If no  
authorization is obtained, or the product is deemed not repairable, Transition  
Networks will retain the $200.00 service charge and return the product to the  
customer not repaired. Non-warranted products that are repaired by Transition  
Networks for a fee will carry a 180-day limited warranty. All warranty claims are  
subject to the restrictions and conventions set forth by this document.  
Transition Networks reserves the right to charge for all testing and shipping incurred,  
if after testing, a return is classified as "No Problem Found."  
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS  
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.  
TRANSITION NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT,  
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS  
OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS  
ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON  
TRANSITION NETWORKS' BEHALF.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toastmaster Popcorn Poppers TPC2 User Manual
Triarch Indoor Furnishings 75360 10 User Manual
Uniden Marine Radio UH076DLX User Manual
Verilux Landscape Lighting VD11 User Manual
Victory Refrigeration Refrigerator VM 2S User Manual
ViewSonic MP3 Player VS12835 User Manual
Viking Electronics Video Gaming Accessories DVA 2W User Manual
Vivitar Digital Camera S529 User Manual
Weber Gas Grill 55062 User Manual
Weber Gas Grill genesis silver b natural gas grill User Manual