Transition Networks Power Supply CPSMP 130 User Manual

User’s Guide  
+
+
CPSMP-130  
48-VDC Power Supply Module  
0
I
+
CPSMP-140  
-
+
+
24-VDC Power Supply Module  
13-Slot PointSystem™ Accessory  
The Transition Networks CPSMP-130 power supply is a 48-VDC slide-in-module  
that provides optional, redundant power to the CPSMC1310-100 13-slot  
PointSystem™ chassis and any installed media converter slide-in-modules and  
management modules.  
The Transition Networks CPSMP-140 power supply is a 24-VDC slide-in-module  
that provides optional, redundant power to the CPSMC1320-100 13-slot  
PointSystem™ chassis and any installed media converter slide-in-modules and  
management modules.  
The figure below illustrates the components of both types of power supplies:  
An On/Off switch that, when set to “I”, allows the power supply module  
to supply power to the chassis, and any installed modules.  
A panel fastener screw that secures the power supply module to the  
chassis.  
A power LED indicator.  
A handle for installing and removing the power supply module to/from  
the chassis.  
A fuse installed on the circuit board inside the power supply module’s  
housing.  
A set of three (3) external power connectors that distribute power from an  
external DC outlet to a chassis ground connector, a positive (+)  
connector, and a negative (-) connector on the power supply module.  
On/Off Switch  
Panel Fastener Screw  
Install the Power Supply Module . . . . .3  
Power LED  
I
0
Connect to External Power . . . . . . . . .4  
Replace the Power Supply Module . . .6  
Replace the Fuse . . . . . . . . . . . . . . . . .8  
Handle  
Technical Specifications . . . . . . . . . .10  
Troubleshooting . . . . . . . . . . . . . . . .11  
Contact Us . . . . . . . . . . . . . . . . . . . .11  
Compliance Information . . . . . . . . . .12  
Fuse  
(on the circuit board  
External Power Connectors  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMP-130 & CPSMP-140  
Connect to External Power  
Connect to External Power -- Continued  
CAUTION: Ensure that external power source is NOT powered and that the  
On/Off switch on the power supply module is set to “0” when connecting to  
the external power source. Failure to observe this caution could result in  
damage to, and subsequent failure of, the power supply module.  
To power the CPSMP-130 or the CPSMP-140 power supply module:  
1. Set the On/Off switch on the power supply module to “0”.  
2. Verify that the external power source is NOT powered.  
3. Connect the positive (+) terminal to the external power connector marked  
“+”. Turn the terminal screw clockwise to secure.  
48-VDC power supply  
4. Connect the negative (-) terminal to the external power connector marked  
“-”. Turn the terminal screw clockwise to secure.  
This product is intended to be used in a restricted access location. Proper  
earthing (grounding) is required to ensure safe operation and to comply  
with customer installation requirements and local electrical codes. Prior  
to installation, use a voltmeter/ohmmeter to check the wiring for the  
presence of earth ground.  
5. Connect the ground terminal to the external power connector marked  
“chassis ground”. Turn the terminal screw clockwise to secure.  
6. Set the power supply module power switch to “I”.  
7. Verify that the power supply module is powered by observing the  
illuminated power LED.  
A readily accessible disconnect device as part of the building installation  
shall be incorporated into the fixed wiring. The disconnect device (a 48  
VDC, 15 or 20A circuit breaker or switch) must be included in the  
ungrounded supply conductor. Overcurrent protection must be a 48  
VDC, 15 or 20A fuse or circuit breaker.  
Panel Fastener Screw  
Power LED  
On/Off  
Switch  
0
I
0
I
24-VDC Power Supply  
GND  
This product is intended to be used in a restricted access location. Proper  
earthing (grounding) is required to ensure safe operation and to comply  
with customer installation requirements and local electrical codes. Prior  
to installation, use a voltmeter/ohmmeter to check the wiring for the  
presence of earth ground.  
External Power Connectors  
A readily accessible disconnect device as part of the building installation  
shall be incorporated into the fixed wiring. The disconnect device (a 24  
VDC, 15 or 20A circuit breaker or switch) must be included in the  
ungrounded supply conductor. Overcurrent protection must be a 24  
VDC, 15 or 20A fuse or circuit breaker.  
5
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMP-130 & CPSMP-140  
WARNING: Do NOT connect the power supply module to the external power  
source before installing it into the chassis. Failure to observe this caution could  
result in equipment damage and/or personal injury or death.  
Replace the Power Supply Module -- Continued  
8. Carefully slide the replacement power supply module into the installation  
slot, aligning the module with the installation guides.  
Replace the Power Supply Module  
0
I
CAUTION: Ensure that the power supply module has been disconnected  
from the external power source and the module’s On/Off switch has been  
set to “0”. Failure to observe this caution could result in damage to, and  
subsequent failure of, the power supply module.  
-
0
+
I
NOTE: The power supply module may be “hot swapped” (i.e., replaced while  
the chassis is in operation) provided the module to be replaced has been  
disconnected from its external power source and the module’s On/Off  
switch has been set to “0”.  
-
+
9. Ensure that the power supply module is firmly seated inside the chassis.  
To replace the CPSMP-130 or the CPSMP-140 power supply module:  
1. Set the On/Off switch on the power supply module to “0”.  
2. Verify that the external power source is NOT powered.  
10. Rotate the attached panel fastener screw clockwise to secure the power  
supply module to the chassis.  
11. See the “Connect to External Power” section (page 5) for instructions on  
re-connecting the power supply module to the external power source.  
3. Disconnect the positive(+) terminal from the external power connector  
marked “+”.  
4. Disconnect the negative (-) terminal from the external power connector  
marked “-”.  
5. Disconnect the ground terminal from the external power connector  
marked “chassis ground”.  
6. Rotate the attached panel fastener screw counter-clockwise.  
On/Off  
Panel Fastener Screw  
Power LED  
Switch  
0
I
0
I
GND  
External Power Connectors  
7. Carefully slide the power supply to be replaced out of the chassis.  
0
I
-
0
+
I
-
+
7
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMP-130 & CPSMP-140  
WARNING: Do NOT connect the power supply module to the external power  
source before installing it into the chassis. Failure to observe this caution could  
result in equipment damage and/or personal injury or death.  
Replace the Fuse  
CAUTION: Ensure that the power supply module has been disconnected  
from the external power source and the module’s On/Off switch has been  
set to “0”. Failure to observe this caution could result in damage to, and  
subsequent failure of, the power supply module.  
8. Remove the four (4) screws that secure the panel to the module (see the  
drawing below) and remove the panel from module.  
NOTE: The power supply module may be “hot swapped” (i.e., serviced while  
the chassis is in operation) provided the module to be serviced has been  
disconnected from its external power supply and the module’s On/Off  
switch has been set to “0”.  
0
I
+
1
To replace the fuse in the CPSMP-130 or CPSMP-140 power supply module:  
1. Set the On/Off switch on the power supply module to “0”.  
2. Verify that the external power source is NOT powered.  
0
I
+
+
-
+
+
3. Disconnect the positive (+) DC terminal from the external power  
connector marked “+”.  
4. Disconnect the negative (-) DC terminal from the external power  
connector marked “-”.  
Remove these four (4) screws  
to access the fuse  
5. Disconnect the ground terminal from the external power connector  
marked “chassis ground”.  
9. The fuse is located inside the power supply module on the circuit board.  
Remove the fuse from the fuse holder.  
On/Off  
Panel Fastener Screw  
Power LED  
10. Install a same size and rating replacement fuse in the fuse holder.  
Switch  
0
I
0
I
11. Replace the panel to the power supply module and secure it in place  
with the four (4) screws.  
GND  
12. Carefully slide the power supply module into the installation slot,  
aligning the module with the installation guides.  
External Power Connectors  
0
I
6. Rotate the attached panel fastener screw counter-clockwise.  
7. Carefully slide the power supply module out of the chassis.  
-
0
I
+
-
0
I
+
-
0
+
I
13. Ensure that the power supply module is firmly seated inside the chassis.  
14. Rotate the attached panel fastener screw clockwise to secure the power  
supply module to the chassis.  
-
+
15. See the “Connect to External Power” section (page 5) for instructions on  
re-connecting the power supply module to the external power source.  
9
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CPSMP-130 & CPSMP-140  
Technical Specification  
Troubleshooting  
For use with Transition Networks model CPSMP-130 or CPSMP-140 or equivalent.  
If the power supply module fails, isolate and correct the failure by determining  
the answers to the following questions and then taking the indicated action:  
Standards  
Dimensions  
Weight  
UL Listed; FCC & CISPR Class A; CE Mark  
3.4" x 2.5" x 11.0" (86 mm x 64 mm x 279 mm)  
1.8 lb (0.8 kg) (approximate)  
1.  
Is the power LED on the power supply module illuminated?  
NO  
Is the power supply module inserted properly into the chassis?  
Is the power supply module properly connected to the external  
power source?  
CPSMP-130  
Power Input:  
48VDC (38 to 58VDC) @ 2.63Amp  
(typical for a fully-loaded chassis)  
Power Output:  
Power Input:  
+12 VDC @ 12.5 Amp (maximum)  
Does the external power source provide power?  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
CPSMP-140  
24VDC (20 to 31VDC) @ 4.83 Amp  
(typical for a fully-loaded chassis)  
YES  
Power Output:  
6.3Amp / 250V  
+12 VDC @ 8.3 Amp (maximum)  
Proceed to step 2.  
Fuse  
2.  
Is the fuse on the power supply intact?  
NO  
MTBF  
520,441 hours (MIL217F2 V5.0) (MIL-HDBK-217F)  
1,087,866 hours (Bellcore7 V5.0)  
CAUTION: See the “Replacing the Fuse” section (page 8) in this  
user’s guide for the proper method for replacing the fuse to the  
power supply module.  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
Environment  
Tmra**:  
0 to 50°C (32 to 122°F )  
-20 to 85°C (-4 to 185°F)  
10 to 90%, non condensing  
0 to 10,000 feet  
Storage Temp:  
Humidity:  
Altitude:  
Warranty  
Lifetime  
YES  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
**Manufacturer’s rated ambient temperature: Tmra range for these power supply  
modules depend on the physical characteristics and the installation configuration  
of the Transition Networks PointSystem™ chassis in which this slide-in-module  
will be installed.  
For the most up-to-date information on the CPSMP-130 and CPSMP-140 power  
supply modules, view the user’s guide on-line at: www.transition.com.  
Contact Us  
Technical Support  
Technical support is available 24 hours a day.  
US and Canada:  
International:  
1-800-260-1312  
00-1-952-941-7600  
Transition Now  
Chat live via the Web with Transition Networks Technical Support.  
Log onto www.transition.com and click the Transition Now link.  
Web-Based Seminars  
Transition Networks provides seminars via live web-based training.  
Log onto www.transition.com and click the Learning Center link.  
E-Mail  
Ask a question anytime by sending an e-mail to our technical support staff.  
Address  
Transition Networks, 6475 City West Parkway, Minneapolis, MN 55344, USA  
telephone: 952-941-7600, toll free: 800-526-9267, fax: 952-941-2322  
11  
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
UL Listed; C-UL Listed (Canada); CE Mark  
CISPR22/EN55022 Class A  
FCC Regulations  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio frequency energy and, if  
not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is  
likely to cause harmful interference, in which case the user will be required to correct the  
interference at the user's own expense.  
Canadian Regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus  
set out on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites  
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le  
brouillage radioélectrique édicté par le ministère des Communications du Canada.  
European Regulations  
Warning This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können  
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für  
entsprechende Gegenmaßnahmen werantwortlich ist.  
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit  
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de  
prende les measures spécifiques appropriées.  
Declaration of Conformity  
Name of Mfg:  
Transition Networks  
6475 City West Parkway, Minneapolis MN 55344 USA  
Model:  
Part Number(s):  
Regulation:  
Redundant Power Supply  
CPSMP-130, CPSMP-140  
EMC Directive 89/336/EEC  
Purpose: To declare that the CPSMP-130 and CPSMP-140 to which this  
declaration refers are in conformity with the following standards.  
EN 55022:1988 + A1:2000 Class A; FCC Part 15 subpart B; UL 1950  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive(s) and Standard(s).  
June 8, 2001  
Stephen Anderson, Vice-President of Engineering  
Date  
Trademark Notice  
All trademarks and registered trademarks are the property of their respective owners.  
Copyright Restrictions  
© 2001, 2004 Transition Networks. All rights reserved. No part of this work may be  
reproduced or used in any form or by any means - graphic, electronic, or mechanical -  
without written permission from Transition Networks.  
Printed in the U.S.A.  
33213.B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teledyne Marine Instruments 5499 User Manual
Toshiba All in One Printer 2050c User Manual
Tricity Bendix Freezer TB 110 FF User Manual
Tripp Lite TV Cables N546 50M User Manual
Troy Bilt Chipper Csv206 User Manual
True Fitness Elliptical Trainer Touchscreen Elliptical User Manual
Uniden Boating Equipment XSR917 918 User Manual
Viking Convection Oven VESO1302T VEDO1302T User Manual
Vizio Speaker System WSS1A User Manual
Vulcan Hart Griddle MGG24 User Manual