USER’S GUIDE  
N-GxX-xx-01 (standard)  
N-GxX-xx-01(L) (low profile)  
The N-GxX-xx-01(x) gigabit ethernet Network  
Interface Card (NIC) provides a 1000Base-  
SX/LX fiber port to deliver fiber optic  
connectivity to the desktop in fiber-rich LAN  
environments. With both standard and low  
profile form factors, driver support for most  
popular operating systems, and supports 32/64-  
bit PCI 2.2 plug-and-play capability, all help  
make installation a breeze in virtually any PC on the Network.  
Part Number  
Port One - Duplex Fiber-Optic 1000Base-SX/LX  
N-GSX-SC-01  
SC, 850 nm multimode, [62.5/125µm: 220 m (722 ft)]  
N-GSX-SC-01(L)  
[50/125µm: 550 m (1804 ft)*]  
N-GSX-SC-01-020**  
SC, 850 nm multimode, [62.5/125µm: 220 m (722 ft)]  
N-GSX-SC-01(L)-020**  
[50/125µm: 550 m (1804 ft)*]  
N-GSX-LC-01  
LC, 850 nm multimode, [62.5/125µm: 220 m (722 ft)]  
N-GSX-LC-01(L)  
[50/125µm: 550 m (1804 ft)*]  
N-GSX-LC-01-020**  
LC, 850 nm multimode, [62.5/125µm: 220 m (722 ft)]  
N-GSX-LC-01(L)-020** [50/125µm: 550 m (1804 ft)*]  
N-GLX-SC-01  
N-GLX-SC-01(L)  
SC, 1310 nm single mode, 10 km (6.2 miles)*  
SC, 1310 nm single mode, 10 km (6.2 miles)*  
N-GLX-LC-01  
N-GLX-LC-01(L)  
Optional accessories sold separately  
Part Number  
Description  
BTR-NGX-PXE  
PXE, Bootable ROM Chip  
*Typical maximum cable distance. Actual distance is dependent upon the physical  
characteristics of the network installation.  
**The -020 designation at the end of the part number means sold in packs of 20  
NICs only. There are no changes to NIC specifications.  
Installation and Configuration . . .2  
Cable Specifications . . . . . . . . . . .4  
Technical Specifications . . . . . . . .5  
Troubleshooting . . . . . . . . . . . . . .6  
Contact Us . . . . . . . . . . . . . . . . . .7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-GxX-xx-01(x) Gigabit Ethernet NIC  
Cable Specifications  
Technical Specifications  
For models N-GxX-xx-01 and N-GxX-xx-01(L)  
Fiber cable  
Bit error rate:  
Single mode fiber (recommended):  
Multimode fiber (recommended):  
Multimode fiber (optional):  
Standards:  
IEEE 802.3™, 802.1P, 802.1Q  
<10-9  
9 µm  
Expansion bus standard:  
Data rate  
PCI 2.2 64/32 bit, 33/66Mhz standard  
1000Mbps fiber media  
62.5/125 µm  
100/140, 85/140, 50/125 µm  
LED:  
LINK/ACT (on the bracket):  
• ON = communication link;  
• FLASHING = activity on link  
FDX (on the bracket): ON = full duplex link  
N-GSX-SC-01(x)  
850 nm multimode  
min: -9.5 dBm  
min: -18.0 dBm max: -0.0 dBm  
8.5 dB  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
max: -4.0 dBm  
Drivers:  
• NetWare Server 4.x, 5.x; 6.x  
• Netware DOS Client ODI  
• Windows 98, 2000, 2003, NT4.0, XP  
• Linux  
• SCO UnixWare 7.1x  
• OpenUnix 8.0  
N-GSX-LC-01(x)  
850 nm multimode  
min: -9.5 dBm  
min: -18.0 dBm max: -0.0 dBm  
8.5 dB  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
max: -4.0 dBm  
N-GLX-SC-01(x)  
1310 nm single mode  
min: -9.5 dBm  
min: -20.0 dBm max: -3.0 dBm  
10.5 dB  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
max: -3.0 dBm  
Boot server support:  
PCB dimensions:  
PXE Boot ROM  
2.2” x 6.5” x .09”  
(56 mm x 165 mm x 23 mm)  
N-GLX-LC-01(x)  
1310 nm single mode  
min: -9.5 dBm  
min: -20.0 dBm max: -3.0 dBm  
10.5 dB  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
max: -3.0 dBm  
Shipping weight:  
Power consumption:  
MTBF  
Opearting temp:  
Storage temp:  
Humidity:  
1 lb. (0.45 kg.)  
2.0A @ +5VDC  
127,234 hours (Bellcore7 V5.0)  
0°C to 50°C (32°F to 122°F)  
-25°C to 85°C (-13°C to 185°F)  
5% to 95%, non-condensing  
0 to 10,000 feet  
The fiber optic transmitters on the device meet Class I Laser safety requirements  
per IEC-825/CDRH standard and comply with 21CRF1040.10 and  
21CRF1040.11.  
Altitude:  
Warranty:  
Lifetime  
WARNING: Visible and invisible laser radiation when open: DO NOT stare into  
the beam or view directly with optical instruments. Failure to observe this warning  
could result in damage to your vision or blindness.  
WARNING: Use of controls, adjustments, or the performance of procedures other  
than those specified herein may result in hazardous radiation exposure.  
The information in this manual is subject to change without further notice. Go to  
to check for updates to this manual by checking the revision level.  
5
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours  
[email protected] -- Click the “Transition Now” link for live Web chat.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-GxX-xx-01(x) Gigabit Ethernet NIC  
Troubleshooting  
Diagnostics LEDs and Boot ROM  
Contact Us  
Technical support  
Technical support is available at [email protected]  
LEDS  
• US and Canada:  
• International:  
1-800-260-1312 (24 hours)  
The Link/ACT LED (green) turns ON when cable connection is good and  
00-1-952-941-7600 (24 hours)  
speed is at 1000Mpbs.  
Transition now  
The FDX LED (green) truns ON when full-duplex mode is active.  
Chat live via the Web with Transition Networks Technical Support. Log onto  
Boot ROM  
Web-based seminar  
Transition networks provides seminars via live, web-based training. Log onto  
To add the remote boot feature to a workstation, insert the Boot ROM into the  
ROM socket. See Figure 1 on page 2.  
After power UP, the LINK/ACT LED should light; if not, check the following:  
Email  
1
Confirm that the N-GxX-xx-01(x) NIC is properly inserted into the master  
slot.  
Ask a question anytime by sending an email to our technical support staff:  
2
Confirm that the PC is properly connected to a power source and with the  
power source turned ON.  
Address  
Transition Networks  
3
4
Check the fiber cable for proper connection.  
6475 City West Parkway  
Minneapolis, MN 55344, U.S.A.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600 if those  
steps fail to produce the desired result.  
Telephone:  
Toll free:  
Fax:  
952-941-7600,  
800-526-9267  
952-941-2322  
Note: To connect this device to a router, bridge, or switch, please refer to the  
corresponding technical manual for the device.  
Declaration of Conformity  
Name of Mfg:  
Transition Networks, 6475 City West Parkway,  
Minneapolis, MN 55344 U.S.A.  
Model:  
N-GxX-xx-01 and N-GxX-xx-01(L) Network Interface Cards  
Part Number:  
N-GSX-SC-01(x), N-GSX-LC-01(x), N-GLX-SC-01(x)  
N-GLX-LC-01(x)  
Regulation:  
Purpose:  
EMC Directive 89/336/EEC  
To declare that theN-GxX-xx-01 and N-GxX-xx-01(L) to which  
this declaration refers is in conformity with the following  
standards:  
CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 Subpart B;  
21CFR subpart J  
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s)  
and Standard(s).  
September 9, 2005  
Stephen Anderson, Vice-President of Engineering  
Date  
7
6
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours  
[email protected] -- Click the “Transition Now” link for live Web chat.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-GxX-xx-01(x) Gigabit Ethernet NIC  
Compliance Information  
CISPR22/EN55022 Class A, CE Mark, CISPR22/EN55022 Class A + EN55024, CE Mark  
FCC regulations  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference, in which  
case the user will be required to correct the interference at the user's own expense.  
Canadian regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out  
on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables  
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage  
radioélectrique édicté par le ministère des Communications du Canada.  
European regulations  
Caution: This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei  
Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für  
Gegenmaßnahmen verantwortlich.  
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de  
créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures  
spécifiques appropriées.  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-  
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über  
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  
Konformität.  
Trademark notice  
All registered trademarks and trademarks are the property of their respective owners.  
Copyright restrictions  
© 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or  
used in any form or by any means—graphic, electronic or mechanical—without written permission  
from Transition Networks  
33347.A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printed in the U.S.A.  
Manual Part Number and Rev.A  
8

Taylor Scale 2004 User Manual
Teledex Cordless Telephone Cordless Handset User Manual
Teledyne TV Converter Box 3020P User Manual
Toastmaster Oven TOV425RLCAN User Manual
Tote Vision Computer Monitor LCD 800 User Manual
Tripp Lite Network Card B120 000 User Manual
Velodyne Acoustics Speaker System and SPL 1200 User Manual
ViewSonic Network Card WMG120 User Manual
Weber Charcoal Grill 56224_051010 User Manual
Weber Griddle 55249 User Manual