Trane Furnace 22 1671 04 0702 EN 7 User Manual

TDD-D-1  
Downflow/Horizontal Right  
or Downflow/Horizontal Left  
Induced Draft Gas Furnace  
XR 80  
TDD040,060,080,100,120,140C  
Single-Stage Fan Assisted  
Combustion System  
PUB. NO. 22-1671-04-0702 (EN)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
General Features  
2
4
Features and Benefits  
Standard Equipment  
4
Optional Equipment  
5
General Data  
6
TDD040C924F  
TDD060C924F  
TDD060C936F  
TDD080C936F  
TDD080C945F  
TDD100C945F  
TDD100C948F  
TDD100C954F  
TDD120C954F  
TDD120C960F  
TDD140C960F  
6
6
6
7
7
7
8
8
8
9
9
Performance Data  
Electrical Data  
Field Wiring  
10  
12  
13  
15  
Dimensions  
22-1671-04-0702 (EN)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features and  
Benefits  
XR 80 Downflow/Horizontal Right or Left  
Standard Equipment  
• Power supply 115/1/60  
• Multi-port In-shot burners  
• Quiet slow opening gas valve  
• Downflow convertible to horizontal on  
left or right side  
• Integrated solid state control with self-  
diagnostics  
• Insulated blower door  
• Silicon Nitride hot surface igniter with  
adaptive heat up  
• Insulated blower compartment  
• Accessory hook-up capability –  
Hum and EAC  
• Complete front service access  
• Heavy gauge aluminized steel heat  
exchanger  
• Quiet induced draft blower  
• Blower door safety switch  
• Left/right gas connection  
• 24 volt fuse  
• Slide out blower assembly  
• Blower door safety switch  
• Direct drive, 4-speed motor  
• Cleanable high velocity filters  
• Optional L.P. conversion kit  
• Common vent  
• Manual reset burner box limit  
Non-prorated 20-year heat  
exchanger limited warranty  
5-year limited parts warranty  
• Left and right side knockout for venting  
• Selectable cooling fan off delay  
eliminates need for BAY24X045 time  
delay relay  
4
22-1671-04-0702 (EN)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features and  
Benefits  
Optional Equipment  
Thermostat ............................................................................................................................................................... BAYSTAT388 [ ]  
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................. AY28X092 [ ]  
Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................. BAYSTAT305 [ ]  
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................... TAYSTAT300C [ ]  
Propane Conversion Kit .......................................................................................................................................... BAYLPKT210A [ ]  
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ....................................................... TFE145A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ....................................................... TFE175A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................. TFE210A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ....................................................... TFE245A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ........................................................ TFM145A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ........................................................ TFM175A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) .............................................................. TFM210A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ........................................................ TFM245A9FR1 [ ]  
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................ TFP175A9FR01 [ ]  
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................... TFP210A9FR01 [ ]  
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................ TFP245A9FR01 [ ]  
Coil Enclosure (14-1/2" Wide Cabinets) ................................................................................................................. BAYCLE1400C [ ]  
Coil Enclosure (17-1/2" Wide Cabinets) ................................................................................................................. BAYCLE1700C [ ]  
Coil Enclosure (21" Wide Cabinets) ....................................................................................................................... BAYCLE2100C [ ]  
Coil Enclosure (24-1/2" Wide Cabinets) ................................................................................................................. BAYCLE2400C [ ]  
Filter Access Door Kit............................................................................................................................................... BAYFLTR206 [ ]  
Downflow Subbase .................................................................................................................................................. BAYBASE205 [ ]  
High Altitude Pressure Switch Kit .............................................................................................................................. BAYHALT248 [ ]  
22-1671-04-0702 (EN)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
Product Specifications 1  
MODEL  
TYPE  
TDD040C924F  
TDD060C924F  
TDD060C936F  
Downflow / Horizontal  
Downflow / Horizontal  
Downflow / Horizontal  
RATINGS  
2
Input BTUH  
40,000  
31,000  
80.0  
60,000  
48,000  
80.0  
60,000  
48,000  
80.0  
Capacity BTUH (ICS) 3  
AFUE  
Temp. rise (Min.-Max.) °F.  
30 - 60  
35 - 65  
30 - 60  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
10 x 6  
DIRECT  
10 x 7  
DIRECT  
11 x 7  
1
4
1
4
1
4
See Fan Performance Table  
See Fan Performance Table  
See Fan Performance Table  
1/5  
1/5  
1/2  
R.P.M.  
Volts / Ph / Hz  
1075  
115/1/60  
1075  
115/1/60  
1075  
115/1/60  
COMBUSTION FAN - Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts / Ph / Hz  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Yes  
High Velocity  
2 - 14x20 - 1in.  
Yes  
High Velocity  
2 - 14x20 - 1in.  
Yes  
High Velocity  
2 - 14x20 - 1in.  
VENT — Size (in.)  
4 Round  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Gauge (Fired)  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
2 — 45  
2 — 56  
3 — 45  
3 — 56  
3 — 45  
3 — 56  
GAS VALVE  
Redundant - Single Stage  
Redundant - Single Stage  
Redundant - Single Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS — Type  
Number  
Multi-port In-shot  
2
Multi-port In-shot  
3
Multi-port In-shot  
3
POWER CONN. — V / Ph / Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
5.2  
115/1/60  
5.2  
115/1/60  
11.2  
10  
15  
15  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41 x 15-1/2 x 29-1/2  
H x W x D  
41 x 15-1/2 x 29-1/2  
H x W x D  
41 x 15-1/2 x 29-1/2  
WEIGHT  
Shipping (Lbs.) / Net (Lbs)  
119 / 109  
129 / 119  
129 / 119  
1 Central Furnace heating designs are certified by AGA and CSA.  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.  
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
6
22-1671-04-0702 (EN)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
Product Specifications 1  
MODEL  
TYPE  
TDD080C936F  
TDD080C945F  
TDD100C945F  
Downflow / Horizontal  
Downflow / Horizontal  
Downflow / Horizontal  
RATINGS  
2
Input BTUH  
80,000  
64,000  
80.0  
80,000  
64,000  
80.0  
100,000  
80,000  
80.0  
Capacity BTUH (ICS) 3  
AFUE  
Temp. rise (Min.-Max.) °F.  
35 - 65  
35 - 65  
35 - 65  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
10 x 7  
DIRECT  
10 x 8  
DIRECT  
10 x 8  
1
4
1
4
1
4
See Fan Performance Table  
See Fan Performance Table  
See Fan Performance Table  
1/3  
1/3  
1/3  
R.P.M.  
Volts / Ph / Hz  
1075  
115/1/60  
1075  
115/1/60  
1075  
115/1/60  
COMBUSTION FAN - Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts / Ph / Hz  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3200  
115/1/60  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Yes  
High Velocity  
2 - 14x20 - 1in.  
Yes  
High Velocity  
2 - 16x20 - 1in.  
Yes  
High Velocity  
2 - 16x20 - 1in.  
VENT — Size (in.)  
4 Round  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Gauge (Fired)  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
4 — 45  
4 — 56  
4 — 45  
4 — 56  
5 — 45  
5 — 56  
GAS VALVE  
Redundant - Single Stage  
Redundant - Single Stage  
Redundant - Single Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS — Type  
Number  
Multi-port In-shot  
4
Multi-port In-shot  
4
Multi-port In-shot  
5
POWER CONN. — V / Ph / Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
8.5  
115/1/60  
9.1  
115/1/60  
9.1  
10  
10  
10  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41 x 18-1/2 x 29-1/2  
H x W x D  
41 x 18-1/2 x 29-1/2  
H x W x D  
41 x 18-1/2 x 29-1/2  
WEIGHT  
Shipping (Lbs.) / Net (Lbs)  
146 / 135  
146 / 135  
156 / 145  
1 Central Furnace heating designs are certified by AGA and CSA.  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.  
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
22-1671-04-0702 (EN)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
Product Specifications 1  
MODEL  
TYPE  
TDD100C948F  
TDD100C954F  
TDD120C954F  
Downflow / Horizontal  
Downflow / Horizontal  
Downflow / Horizontal  
RATINGS  
2
Input BTUH  
100,000  
80,000  
80.0  
100,000  
81,000  
80.0  
120,000  
96,000  
80.0  
Capacity BTUH (ICS) 3  
AFUE  
Temp. rise (Min.-Max.) °F.  
35 - 65  
30 - 60  
35 - 65  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
10 x 8  
DIRECT  
11 x 10  
DIRECT  
11 x 10  
1
4
1
4
1
4
See Fan Performance Table  
See Fan Performance Table  
See Fan Performance Table  
1/2  
1/2  
1/2  
R.P.M.  
Volts / Ph / Hz  
1075  
115/1/60  
1075  
115/1/60  
1075  
115/1/60  
COMBUSTION FAN - Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts / Ph / Hz  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Yes  
High Velocity  
2 - 16x20 - 1in.  
Yes  
High Velocity  
2 - 14x20 - 1in.  
Yes  
High Velocity  
2 - 16x20 - 1in.  
VENT — Size (in.)  
4 Round  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Gauge (Fired)  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
5 — 45  
5 — 56  
5 — 45  
5 — 56  
6 — 45  
6 — 56  
GAS VALVE  
Redundant - Single Stage  
Redundant - Single Stage  
Redundant - Single Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS — Type  
Number  
Multi-port In-shot  
5
Multi-port In-shot  
5
Multi-port In-shot  
6
POWER CONN. — V / Ph / Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
14.2  
115/1/60  
12.8  
115/1/60  
12.8  
15  
15  
15  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41 x 22 x 29-1/2  
H x W x D  
41 x 22 x 29-1/2  
H x W x D  
41 x 22 x 29-1/2  
WEIGHT  
Shipping (Lbs.) / Net (Lbs)  
166 / 154  
167 / 155  
170 / 158  
1 Central Furnace heating designs are certified by AGA and CSA.  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.  
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
8
22-1671-04-0702 (EN)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
Product Specifications 1  
MODEL  
TYPE  
TDD120C960F  
TDD140C960F  
Downflow / Horizontal  
Downflow / Horizontal  
RATINGS  
2
Input BTUH  
120,000  
96,000  
80.0  
140,000  
113,000  
80.0  
Capacity BTUH (ICS) 3  
AFUE  
Temp. rise (Min.-Max.) °F.  
35 - 65  
45 - 75  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
11 x 10  
DIRECT  
11 x 10  
1
4
1
4
See Fan Performance Table  
See Fan Performance Table  
1/2  
3/4  
R.P.M.  
Volts / Ph / Hz  
1075  
115/1/60  
1075  
115/1/60  
COMBUSTION FAN - Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts / Ph / Hz  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
Centrifugal  
Direct - 1  
1/50 - 3000  
115/1/60  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Yes  
High Velocity  
2 - 16x20 - 1in.  
Yes  
High Velocity  
2 - 16x20 - 1in.  
VENT — Size (in.)  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Gauge (Fired)  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
6 — 45  
6 — 56  
7 — 45  
7 — 56  
GAS VALVE  
Redundant - Single Stage  
Redundant - Single Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS — Type  
Number  
Multi-port In-shot  
6
Multi-port In-shot  
7
POWER CONN. — V / Ph / Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
12.8  
115/1/60  
13.1  
15  
15  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41 x 25-1/2 x 29-1/2  
H x W x D  
41 x 25-1/2 x 29-1/2  
WEIGHT  
Shipping (Lbs.) / Net (Lbs)  
189 / 176  
196 / 183  
1 Central Furnace heating designs are certified by AGA and CSA.  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.  
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
22-1671-04-0702 (EN)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance  
Data  
FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)  
MODEL  
SPEED TAP  
0.10  
0.20  
0.30  
0.40  
0.50  
0.60  
0.70  
0.80  
0.90  
4 - HIGH - Black  
1070  
870  
740  
633  
1033  
850  
720  
600  
1000  
823  
690  
577  
960  
790  
663  
543  
920  
753  
627  
507  
860  
813  
588  
463  
810  
667  
547  
420  
740  
613  
483  
360  
-
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
490  
-
-
TDD040C924F  
4 - HIGH - Black  
1200  
1025  
838  
1155  
988  
808  
689  
1111  
951  
779  
656  
1056  
905  
742  
618  
1001  
859  
704  
579  
924  
797  
646  
528  
848  
735  
588  
478  
774  
646  
502  
376  
701  
558  
415  
275  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
TDD060C924F  
TDD060C936F  
TDD080C936F  
TDD080C945F  
TDD100C945F  
TDD100C948F  
TDD100C954F  
TDD120C954F  
TDD120C960F  
TDD140C960F  
722  
4 - HIGH - Black  
1480  
1302  
1115  
956  
1429  
1276  
1100  
947  
1375  
1229  
1070  
918  
1318  
1188  
1035  
888  
1282  
1141  
1000  
859  
1100  
1088  
965  
1112  
1024  
918  
1029  
953  
859  
741  
959  
882  
790  
682  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
824  
788  
4 - HIGH - Black  
1523  
1317  
1123  
942  
1496  
1307  
1119  
943  
1463  
1261  
1106  
931  
1420  
1242  
1082  
920  
1369  
1223  
1056  
898  
1310  
1175  
1016  
868  
1243  
1122  
976  
1172  
1060  
930  
1100  
1000  
880  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
833  
795  
760  
4 - HIGH - Black  
1798  
1384  
1210  
1005  
1750  
1367  
1150  
970  
1692  
1333  
1108  
808  
1642  
1300  
1075  
775  
1575  
1275  
1042  
767  
1500  
1233  
1008  
733  
1425  
1192  
967  
1325  
1142  
925  
1225  
1083  
867  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
700  
675  
617  
4 - HIGH - Black  
1767  
1382  
1130  
840  
1731  
1354  
1138  
831  
1669  
1323  
1115  
815  
1615  
1292  
1085  
792  
1546  
1254  
1054  
762  
1469  
1207  
1015  
731  
1392  
1177  
977  
1300  
1108  
938  
1146  
1038  
877  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
700  
654  
625  
4 - HIGH - Black  
1965  
1645  
1407  
1202  
1915  
1627  
1398  
1208  
1865  
1605  
1387  
1205  
1805  
1575  
1375  
1195  
1740  
1535  
1347  
1166  
1670  
1482  
1318  
1140  
1587  
1421  
1275  
1105  
1500  
1330  
1190  
1045  
1370  
1220  
1095  
970  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
4 - HIGH - Black  
2165  
1962  
1705  
1492  
2113  
1927  
1688  
1467  
2060  
1891  
1671  
1442  
1995  
1839  
1636  
1414  
1929  
1786  
1600  
1385  
1842  
1724  
1547  
1346  
1755  
1662  
1492  
1307  
1674  
1581  
1435  
1243  
1593  
1500  
1377  
1179  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
2241  
1981  
1721  
1476  
2202  
1962  
1705  
1466  
2163  
1942  
1688  
1456  
2106  
1904  
1671  
1440  
2049  
1866  
1653  
1423  
1979  
1805  
1611  
1392  
1908  
1743  
1569  
1361  
1804  
1680  
1515  
1302  
1700  
1617  
1461  
1243  
4 - HIGH - Black  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
4 - HIGH - Black  
2241  
1981  
1721  
1476  
2202  
1962  
1705  
1466  
2163  
1942  
1688  
1456  
2106  
1904  
1671  
1440  
2049  
1866  
1653  
1423  
1979  
1805  
1611  
1392  
1908  
1743  
1569  
1361  
1804  
1680  
1515  
1302  
1700  
1617  
1461  
1243  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
4 - HIGH - Black  
2377  
2115  
1806  
1527  
2321  
2081  
1793  
1507  
2265  
2046  
1779  
1486  
2199  
1992  
1738  
1473  
2133  
1938  
1696  
1459  
2050  
1872  
1655  
1422  
1967  
1805  
1614  
1384  
1877  
1727  
1556  
1329  
1786  
1649  
1497  
1273  
3 - MED.-HIGH - Blue  
2 - MED.-LOW - Yellow  
1 - LOW - Red  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22-1671-04-0702 (EN)  
Performance  
Data  
CFM VS. TEMPERATURE RISE  
Cubic Feet Per Minute (CFM)  
MODEL  
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400  
TDD040C924F 59 49 42 37 33  
30  
44  
44  
59  
57  
TDD060C924F  
TDD060C936F  
TDD80C936F  
TDD80C945F  
TDD100C945F  
TDD100C9484F  
TDD100C954F  
TDD120C954F  
TDD120C960F  
TDD140C960F  
63 56 49  
56 49  
40  
40  
54  
52  
37  
59  
48  
62  
62  
62  
34  
46  
44  
57  
57  
57  
32  
42  
41  
53  
53  
53  
64  
49  
49  
49  
59  
59  
69  
46  
46  
46  
56  
56  
65  
44  
44  
44  
52  
52  
61  
41  
41  
41  
49  
49  
58  
39  
39  
47  
47  
55  
37  
37  
44  
44  
52  
35  
42  
42  
49  
34  
40  
40  
47  
32  
45  
31  
22-1671-04-0702 (EN)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical  
Data  
SCHEMATIC DIAGRAMS FOR GAS FURNACES  
From Dwg. 21D341705 Rev. 0  
22-1671-04-0702 (EN)  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Field  
Wiring  
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY  
From Dwg. 21B341437 Rev. 1  
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING  
(OUTDOOR SECTION WITHOUT TRANSFORMER)  
From Dwg. 21B341436 Rev. 1  
22-1671-04-0702 (EN)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Field  
Wiring  
From Dwg. 21B341422 Rev. 1  
From Dwg. 21B341423 Rev. 1  
22-1671-04-0702 (EN)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions  
22-1671-04-0702 (EN)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Literature Order Number  
File Number  
TDD-D-1  
P.I.  
PL-UN-FURN-TDD-D-1  
TDD-D-1 3/98  
Supersedes  
Stocking Location  
PI Louisville & Webb/Mason-Houston 7/02  
TheTraneCompany  
An American Standard Company  
Since The Trane Company has a policy of continuous product and product data improvement, it reserves the  
right to change design and specifications without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Targus Mouse internet multimedia USB keyboard User Manual
TERK Technologies TV Video Accessories Advantage User Manual
Thomas Betts Patio Heater BE User Manual
Timex Watch 810 095009 NA User Manual
Toshiba CRT Television 30HF84 User Manual
Toshiba VCR W 415 User Manual
TP Link Network Card TL WN422G User Manual
Troy Bilt Lawn Mower 31 2 HP User Manual
ViewSonic Digital Photo Frame VMP70 User Manual
Viking Electronics Telephone K 1500 Series User Manual