Split System
Cooling
Product Data
XL15i
4TTX5018A-060A, 049E, 61E
1½ – 5 Tons
PUB. NO. 22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Features and Benefits
2
General Data
4
4
4
5
5
Product Specifications
A-weighted Sound Power Level [dB(A)]
Accessory Description and Usage
AHRI Standard Capacity Rating Conditions
Model Nomenclature
Electrical Data
6
7
Dimensions
10
11
Mechanical Specification Options
22-1817-10
3
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
Product Specifications
Model No. 1
4TTX5018A1
4TTX5024A1
4TTX5030A1
4TTX5036A1
Electrical Data V/Ph/Hz 2
Min Cir Ampacity
Max Fuse Size (Amps)
200/230/1/60
200/230/1/60
200/230/1/60
208/230/1/60
8
15
11
20
15
25
22
35
Compressor
CLIMATUFF®
1-1
6.2 - 38.6
0.74
1/8
CLIMATUFF®
1-1
8.6 - 57.8
0.74
1/8
CLIMATUFF®
1-1
11.1 - 63
0.74
1/8
CLIMATUFF® - SCROLL
No. Used - No Stages
RL Amps - LR Amps
Outdoor Fan FL Amps
Fan HP
1-1
16.7 - 79
0.93
1/5
26.6
Fan Dia (inches)
27.6
27.6
27.6
Coil
Spine Fin™
6/09-LB/OZ
1/2
Spine Fin™
6/10-LB/OZ
5/8
Spine Fin™
6/10-LB/OZ
3/4
Spine Fin™
7/11-LB/OZ
3/4
Refrigerant R-410A
Line Size - (in.) O.D. Gas 3
Line Size - (in.) O.D. Liquid 3
3/8
3/8
3/8
3/8
Dimensions H x W x D (Crated) 45.4 x 35.1 x 38.7
45.4 x 35.1 x 38.7
45.4 x 35.1 x 38.7
53.4 x 35.1 x 38.7
Weight - Shipping
Weight - Net
271
227
275
230
276
232
283
235
Start Components
Sound Enclosure
Compressor Sump Heat
YES
YES
NO
YES
YES
NO
YES
YES
NO
NO
YES
NO
Optional Accessories: 4
Anti-short Cycle Timer
Evaporator Defrost Control A/C
Rubber Isolator Kit
Crank Case Heater Kit
Hard Start Kit Scroll
Extreme Condition Mounting Kit
Snow Leg - Base & Cap 4" High
Snow Leg - 4" Extension
Seacoast Kit
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT300
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT300
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT300
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT301
BAYKSKT260
BAYECMT001
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN7*
BAYECMT001
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN850
BAYECMT001
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN950
BAYECMT001
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN7*
Refrigerant Lineset 5
1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)
4 For accessory description and usage, see page 5.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
A-weighted Sound Power Level [dB(A)]
A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage
SOUND POWER
LEVEL [dB(A)]
MODEL
63
125
250
500
1000
2000
4000
8000
4TTX5018A1
4TTX5024A1
4TTX5030A1
4TTX5036A1
4TTX5042A1
4TTX5048A1
4TTX5049E
4TTX5060A1
4TTX5061E
73
74
73
72
73
73
72
74
73
51
58
65.3
68.2
64.5
66.4
59
51.6
51.5
54.8
53.7
52
59.6
62.8
58.9
55.7
55.9
53.6
54.9
53.8
64.3
64.1
62.1
57.8
68.3
56.8
62.1
58
71.5
68.2
66.8
67.2
67.1
60.9
66.5
64.3
70.5
67.1
66.8
69.2
65.4
61.9
71.4
64.2
64.8
65.7
61.2
65
58.6
60.1
58.8
59.5
58.6
50.4
60.9
54
52.8
54.1
45.4
48.3
48.8
40.7
49.6
47.1
52.1
43.8
52.4
41.8
62.2
57.2
67.2
57.5
Note: Rated in accordance with AHRI Standard 270-2008.
4
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
Product Specifications
Model No. 1
4TTX5042A1
4TTX5048A1
4TTX5049E1
4TTX5060A1
4TTX5061E
Electrical Data V/Ph/Hz 2
Min Cir Ampacity
Max Fuse Size (Amps)
208/230/1/60
208/230/1/60
208/230/1/60
208/230/1/60
230/1/60
39
60
26
45
28
50
28
45
34
60
Compressor
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
No. Used - No. Stages
RL Amps - LR Amps
Outdoor Fan FL Amps
Fan HP
1-1
19.9 - 109
0.93
1/5
27.6
1-1
21.8 - 117
0.93
1/5
27.6
1-1
19.9 - 109
2.8
1/3
27.6
1-1
26.4 - 134
0.93
1/5
27.6
1-2
28.8 - 152.9
2.8
1/3
27.6
Fan Dia (inches)
Coil
Spine Fin™
7/00-LB/OZ
3/4
Spine Fin™
11/00-LB/OZ
7/8
Spine Fin™
11/9-LB/OZ
7/8
Spine Fin™
11/00-LB/OZ
1-1/8
Spine Fin™
12/9-LB/OZ
1-1/8
Refrigerant R-410A
Line Size - (in.) O.D. Gas 3
Line Size - (in.) O.D. Liquid 3
3/8
3/8
3/8
3/8
3/8
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
Weight - Shipping
Weight - Net
305
257
352
302
324
287
354
304
332
295
Start Components
Sound Enclosure
Compressor Sump Heat
NO
YES
NO
NO
YES
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
Optional Accessories: 4
Anti-short Cycle Timer
Evaporator Defrost Control A/C
Rubber Isolator Kit
Crank Case Heater Scroll
Hard Start Kit Scroll
Extreme Condition Mounting Kit BAYECMT001
Snow Leg - Base & Cap 4" High BAYLEGS002
Snow Leg - 4" Extension
Seacoast Kit
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT301
BAYKSKT260
TAYASCT501A
AY28X079
TAYASCT501A
AY28X079
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT301
TAYASCT501A
AY28X079
BAYISLT101
BAYCCHT301
BAYISLT101
BAYCCHT301
BAYKSKT260
BAYECMT001
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN3*
BAYISLT101
BAYCCHT301
BAYKSKT260
BAYECMT004
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN3*
BAYECMT001
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN4*
BAYECMT004
BAYLEGS002
BAYLEGS003
BAYSEAC001
TAYREFLN*4
BAYLEGS003
BAYSEAC001
TAYREFLN7*
Refrigerant Lineset 5
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For 061 units, Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)
4 For accessory description and usage, see page 5.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
22-1817-10
5
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS —
(A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air
entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering out-
door coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering out-
door coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
Accessory Description and Usage
Anti-Short Cycle Timer — Solid state timing device that prevents
compressor recycling until 5 minutes have elapsed after satisfying
call or power interruptions. Use in area with questionable power deliv-
ery, commercial applications, long lineset, etc.
Evaporator Defrost Control — SPST Temperature actuated switch
that cycles the condenser off as indoor coil reaches freeze-up condi-
tions. Used for low ambient cooling to 30°F with TXV.
Rubber Isolators — 5 large rubber donuts to isolate condensing unit
from transmitting energy into mounting frame or pad. Use on any ap-
plication where sound transmission needs to be minimized.
AHRI STANDARD 270 RATING CONDITIONS — (Noise rating
numbers are determined with the unit in cooling operation.) Standard
Noise Rating number is at 95°F outdoor air.
Hard Start kit — Start capacitor and relay to assist compressor mo-
tor startup. Use in areas with marginal power supply, on long linesets,
low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely mount
condensing unit to a frame or pad without removing any panels. Use
in areas with high winds, or on commercial roof tops, etc.
6
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
Nomenclature
4 T
T
X
5
0
3
6
A
1
0
0
0 A
A
T
U
Y
0
8
0
R
9
V
3
W
0
Outdoor Units
G
as Furnaces
Refrigerant Type
2 = R-22
4 = R-410A
Furnace Configuration
TU = Upflow/Horizontal
TD = Downflow/Horizontal
TRANE
Type
C = Condensing
D = Induced Draft
E = Electronic Ignition
X = Direct Vent Condensing
Product Type
W = Split Heat Pump
T = Split Cooling
Product Family
Y = Direct Vent Condensing Variable Speed
Z = Leadership – Two Stage
X = Leadership
R = Replacement/Retail
B = Basic
Heating Input MBTUH
080 = 80,000 BTUH
Major Design Change
A = Light Commercial
C = Single Stage
R = Two Stage
All other = Standard System
Family SEER
0 = 10
1 = 11
2 = 12
3 = 13
4 = 14
5 = 15
6 = 16
8 = 18
9 = 19
Power Supply and Fuel
115 Volt
Natural Gas
Airflow Capacity for Cooling
Example: 36 = 3 Tons
400 CFM/Ton
Split System Connections 1-6 Tons
0 = Brazed
400 x 3 Tons = 1200 CFM
Nominal Capacity in 000s of BTUs
Major Design Modifications
V3 = 1 1/2 – 3 Tons, Variable Speed Motor (ICM)
V4 = 2 – 4 Tons, Variable Speed Motor (ICM)
V5 = 3 – 5 Tons, Variable Speed Motor (ICM)
Power Supply
1 = 200-230/1/60 or 208-230/1/60
3 = 200-230/3/60
Minor Design Change
4 = 460/3/60
Service Digit – Not Orderable
Secondary Function
Minor Design Modifications
Unit Parts Identifier
4 T
E
E
3
F
3
6
A
1
0
0
0 A
A
T
X
C
0
2
4
C
4
H
P
C
0
Air Handlers –
Residential
Refrigerant Type
4 = R-410A
2 = R-22
Furnace Coils
Refrigerant Type
T = R-22
R = R-410A
C = Cooling only
Application
TE = Fully Convertible
TG = Semi Convertible
TF = Front Return
TV = Vertical
Furnace Coils
XA = Uncased “A” Coil Upflow/Downflow
XC = Cased Coil Upflow/Downflow/Horizontal
XH = Cased Horizontal Only
CB = Cased/Brazed Upflow – Cooling Only
UB = Uncased/Brazed Upflow – Cooling Only
Product Family
E = Leadership – Variable Speed
P = Leadership
C = Replacement/Retail
B = Basic
Coupling
0 = Braze
Flow Control
3 = Nonbleed TXV
4 = FCCV*
Nominal Capacity
Nominal Capacity in 000s of BTUs
Product Family
C = Universal
S = High Efficiency – Nonbleed TXV
E = High Efficiency – Bleed TXV
A = Upflow Only
Feature Identifier
0 = Standard Unit
F = Air-Tite™
Nominal Capacity in 000s of BTUs
Major Design Modifications
D = Reverse Airflow
Power Supply
1 = Single Phase
Refrigerant Control
2 = Cap Tube
3 = Nonbleed TXV
4 = Accutron™ Flow Control/Check Valve (FCCV)
5 = Bleed TXV
Electrical Connection
0 = Pig Tails
B = Circuit Breaker
D = Pull Disconnect
HP = Heat Pump
00 = Cooling only (7 1/2 to 10 ton)
Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
Minor Design Change
Unit Parts Identifier
Service Digit – Not Orderable
NOTE: There will be a phase-in of new model numbers for new
air handlers over next 2 years.
*Shipped with R-22 FCCV
22-1817-10
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX5018A
Printed from D156722P01
© 2010 Trane
8
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX5024A
Printed from D156722P01
22-1817-10
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX5030A
Printed from D156722P01
10
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX5036A
Printed from D156910P01
22-1817-10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
4TTX5042A
Printed from D156552P01
12
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
4TTX5048A
Printed from D156578P01v
22-1817-10
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
4TTX5060A
Printed from D156060P03
14
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
4TTX5049E
Printed from D156677P01
22-1817-10
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
4TTX5061E
Printed from D156678P02
16
22-1817-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
LEGEND
22-1817-10
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
4TTX5 Outline Drawing
Note: All dimensions are in MM (Inches).
MODELS
4TTX5018A
4TTX5024A
4TTX5030A
4TTX5036A
4TTX5042A
4TTX5048A
4TTX5049E
4TTX5060A
4TTX5061E
BASE
FIG.
1
A
B
C
D
E
F
G
H
J
K
4
4
4
4
4
4
4
4
4
1064 (41-7/8)
1064 (41-7/8)
1064 (41-7/8)
1267 (49-7/8)
1267 (49-7/8)
1369 (53-7/8)
1369 (53-7/8)
1369 (53-7/8)
1369 (53-7/8)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
870 (34-1/4)
1/2
5/8
3/4
3/4
3/4
7/8
7/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
152 (6)
152 (6)
152 (6)
152 (6)
152 (6)
152 (6)
152 (6)
152 (6)
152 (6)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
98 (3-7/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
219 (8-5/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
86 (3-3/8)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
1
1
1
1
1
1
1
1-1/8 3/8
1-1/8 3/8
1
18
Download from Www.Somanuals.com. All Manuals Search And Download.
22-1817-10
Mechanical
Specification Options
General
Condenser Coil
The 4TTX5 is fully charged from the
factory for up to 15 feet of piping. This
unit is designed to operate at outdoor
ambient temperatures as high as 115°F.
Cooling capacities are matched with
a wide selection of air handlers and
furnace coils that are AHRI certified. The
unit is certified to UL 1995. Exterior is
designed for outdoor application.
The outdoor coil provides low airflow
resistance and efficient heat transfer.
The coil is protected on all four sides by
louvered panels.
Low Ambient Cooling
As manufactured, this unit has a cool-
ing capability to 55°F. The addition of
an evaporator defrost control with TXV
permits low ambient cooling to 30°F.
Casing
Accessories
Unit casing is constructed of heavy
gauge, G90 galvanized steel and
painted with a weather-resistant powder
paint
Thermostats — Cooling only and heat/
cooling (manual and automatic change-
over). Sub-base to match thermostat
and locking thermostat cover.
on all louvers, panels, prepaint on all
other panels. Corrosion and weather-
proof CMBP-G30 DuraTuff™ base.
Evaporator Defrost Control — See
Low Ambient Cooling.
Refrigerant Controls
Refrigeration system controls include
condenser fan, compressor contactor
and high pressure switch. High and low
pressure controls are inherent to the
compressor. A factory installed liquid line
drier is standard.
Compressor
The Climatuff® compressor features
internal over temperature and pressure
protection and total dipped hermetic
motor. Other features include: roto lock
suction and discharge refrigerant con-
nections, centrifugal oil pump and low
vibration
and noise.
22-1817-10
19
Download from Www.Somanuals.com. All Manuals Search And Download.
05/11
Literature Order Number
File Number
Supersedes
Stocking Location
Trane
A business of
American Standard Companies
Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.