Toshiba Portable Media Storage DFP 2000A User Manual

No. MIIXR0002EAC  
DICOM CONFORMANCE STATEMENT  
MEDIA STORAGE  
FOR  
TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM  
MODEL DFP-2000A  
with XIDF-037A and XIDF-038A  
or  
SRS-1000A  
(MIIXR0002EAC)  
2001  
Download from Www.Somanuals.com. All Manuals Search And Download.  
No. MIIXR0002EAC  
Table of Contents  
Page  
- a -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
No. MIIXR0002EAC  
- b -  
*
Download from Www.Somanuals.com. All Manuals Search And Download.  
No. MIIXR0002EAC  
1 Introduction  
This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography  
Systems. It is intended to provide the reader with the knowledge of how to integrate this product  
within DICOM compliant equipments. It details the DICOM Service Classes, Information  
Objects, and Application Profiles which are supported by this product.  
If the reader is unfamiliar with DICOM, it is recommended that they read the DICOM  
Specification (referenced below) prior to reading this conformance statement. Also note that  
this document is formatted according to the DICOM Specification, Part 2: Conformance.  
1.1 References  
ACR-NEMA Digital Imaging and Communications in Medicine, DICOM V3.0.  
1.2 Definitions  
Information Object Definition (IOD) - An IOD is a data model which is an abstraction of  
real-world information. This data model defines the nature and attributes relevant to the  
class of real-world objects represented.  
Service/Object Pair (SOP) Class - A SOP Class is defined by the union of an Information  
Object Definition and a set of DIMSE Services. A DICOM Application Entity may support  
one or more SOP Classes. Each SOP Class is uniquely identified by a SOP Class UID.  
SOP Instance - A specific occurrence of a Information Object.  
Transfer Syntax - The Transfer Syntax is a set of encoding rules that allow DICOM  
Application Entities to negotiate the encoding techniques (e.g. data element structure, byte  
ordering, compression) they are able to support.  
Unique Identifier (UID) - A Unique Identifier is a globally unique, ISO compliant,  
ASCII-numeric string. It guarantees uniqueness across multiple countries, sites, vendors  
and equipment.  
- 1 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
1.3 Acronyms, Abbreviations and Symbols  
ACC  
ACR  
ASCII  
AE  
American College of Cardiology  
American College of Radiology  
American Standard Code for Information Interchange  
Application Entity  
ANSI  
AP  
American National Standards Institute  
Application Profile  
CEN TC251 Comite Europeen de Normalisation - Technical Committee 251 - Medical  
Informatics  
DICOM  
FSC  
FSR  
FSU  
IOD  
Digital Imaging and Communications in Medicine  
File-set Creator  
File-set Reader  
File-set Updater  
Information Object Definition  
International Standards Organization  
Japan Industries Association of Radiological Systems  
National Electrical Manufacturers Association  
Real-World Activity  
ISO  
JIRA  
NEMA  
RWA  
SOP  
UID  
Service-Object Pair  
Unique Identifier  
- 2 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
2 Implementation Model  
2.1 Application Data Flow Diagram  
Transfer of  
X-ray  
Examination  
DICOM  
Recording  
CD-R  
Medium  
Review of  
X-ray  
Examination  
DICOM  
Reader  
Legend  
Application Entity  
Local Real-World Activity  
File-set Creator (FSC)  
File-set Reader (FSR)  
Local Relationship  
Figure 1  
2.2 Functional Definitions of AE's  
2.2.1 DICOM Recording  
The DICOM Recording supports the following tasks:  
Builds DICOM XA Information Objects.  
Creates a DICOMDIR file that represents the contents of DICOM XA Information  
Objects to be recorded.  
Records DICOM XA Information Objects and DICOMDIR from the local storage to  
the CD-R media.  
Duplicates the File-set of the CD-R media or the local storage onto the blank CD-R  
media.  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
2.2.2 DICOM Reader  
The DICOM Reader supports the following tasks:  
Reads the DICOMDIR file that represents the contents of the data as recorded.  
Displays the ordered list of patient and image identifying information or icon  
images.  
Reads the selected image SOP instance from the CD-R media and displays it on  
the monitor of the DICOM Reader.  
Reads the File-set of the CD-R media and writes it onto the local storage of DICOM  
Reader.  
2.3 Sequencing of Real World Activities  
2.3.1 Features  
2.3.1.1 Transfer of X-ray Examination  
Operator requests to transfer images to the local storage after selecting the transferred  
images from the Patient List or from the Image List.  
Operator requests to record the images of the local storage onto the CD-R media after  
transferring all data that are to be recorded.  
When the size of images exceeds the capacity of a single CD-R, the request of  
transferring images is canceled.  
Each CD-R media has a DICOMDIR file that represents the contents of the data as  
recorded.  
Operator can request to duplicate the CD-R media from the recorded CD-R media to the  
blank CD-R media  
2.3.1.2 Review of X-ray Examination  
Operator inserts the CD-R media to be read.  
Operator requests to display the list of images or the catalog of icon images that are  
recorded on the CD-R media.  
Operator selects one image from the list or from the thumbnail images and requests to  
review the image from the CD-R media.  
Operator can request to read images from the CD-R media onto the local storage and then  
operator can request to review the image from the local storage.  
Operator can request to delete the images on the local storage.  
The images on the local storage remain after being recorded onto the CD-R media, so  
operators can display these images from the local storage also.  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
2.3.2 Operation  
2.3.2.1 Transfer of X-ray Examination  
The operation for manual transfer of X-ray examination is described below:  
STEP-1: Select the images or the patient to be transferred.  
STEP-2: Request transfer.  
STEP-3: Insert the blank CD-R media.  
STEP-4: Request recording the transferred images onto the CD-R media.  
2.3.2.2 Review of X-ray Examination  
The operation for manual review of X-ray examination is described below:  
STEP-1: Insert the CD-R media to be review.  
STEP-2: Select one image from the list or from the thumbnail images.  
STEP-3: Request forward play, backward play, step by step, or other image processings.  
2.4 File Meta Information for Implementation Class and Version  
File Meta Information Version  
Implementation Class UID  
Implementation Version Name  
0x0001  
1.2.392.200036.9116.31  
TM_XA_DCM_V12  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
3 AE Specifications  
3.1 DICOM Recording Specification  
The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage  
Service, File Format Class and the Media Storage Application Profile.  
Table 1  
Application Profile  
Identifier  
Real World Activity  
Role  
SC Option  
Basic Cardiac X-ray  
Angiographic Studies on  
CD-R Media  
Transfer of X-ray  
Examination  
STD-XABC-CD  
FSC  
Interchange  
1024 X-ray Angiographic  
Studies on CD-R Media  
Transfer of X-ray  
Examination  
STD-XA1K-CD  
FSC  
Interchange  
3.1.1 File Meta Information for the Application Entity  
The Application Entity Title is registered into the DICOM File Meta Information header.  
Source Application Entity Title TM_XA_DCM_V12  
3.1.2 Real-World Activity  
3.1.2.1 Real-World Activity - Transfer of X-ray Examination  
DICOM Recording AE acts as a FSC when chosen by the operator. This AE writes the SOP  
instances onto the CD-R media, creates a DICOMDIR and writes it onto the CD-R media.  
3.1.3 Media Storage Application Profile  
DICOM Recording AE uses the Application Profile defined in Table 1.  
3.1.4 Information Object Definition and DICOMDIR keys  
Information Object Definition and DICOMDIR keys are described in Chapter 8.  
3.2 DICOM Reader Specification  
The DICOM Reader AE provides Conformance to the DICOM Media Storage Service,  
File Format Class and the Media Storage Application Profile.  
Table 2  
Application Profile  
Identifier  
Real World Activity  
Role  
SC Option  
Basic Cardiac X-ray  
Angiographic Studies on  
CD-R Media  
Review of X-ray  
Examination  
STD-XABC-CD  
FSR  
Interchange  
Extended Cardiac X-ray  
Angiographic Studies on  
CD-R Media  
Review of X-ray  
Examination  
AUG-XABC-CD  
FSR  
Interchange  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
3.2.1 File Meta Information for the Application Entity  
The Application Entity Title is not relevant because this DICOM Reader AE only reads CD-R  
media.  
3.2.2 Real-World Activity  
3.2.2.1 Real-World Activity - Review of X-ray Examination  
DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR  
from the CD-R media and reads the SOP instances from the CD-R media.  
3.2.3 Media Storage Application Profile  
DICOM Reader AE uses the Application Profile defined in Table 2.  
3.2.4 Information Object Definition and DICOMDIR keys  
Information Object Definition and DICOMDIR keys are described in Chapter 8.  
4 Augmented and Private Application Profiles  
4.1 Augmented Application Profiles  
DICOM Reader AE supports Augmented Application Profile: AUG-XABC-CD.  
This is a extension of the standard Application Profile: STD-XABC-CD.  
4.1.1 AUG-XABC-CD  
4.1.1.1 SOP Class Augmentations  
None  
4.1.1.2 Directory Augmentations  
None  
4.1.1.3 Other Augmentations  
The following attributes used within the X-ray Angiographic Image files have the specified  
values.  
Table 3  
Attribute Name  
Modality  
Tag  
Value  
(0008, 0060)  
(0028, 0010)  
(0028, 0011)  
(0028, 0100)  
(0028, 0101)  
XA  
1024  
1024  
8
Rows  
Columns  
Bits Allocated  
Bits Stored  
8
4.2 Private Application Profiles  
Not applicable to this product.  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
5 Extensions, Specializations, and Privatizations of SOP  
Classes and Transfer Syntaxes  
Not applicable to this product.  
6 Configuration  
For the Digital Fluorography System, the configuration can be set.  
Note: Settings and changes are performed by Toshiba Service Personnel at the time of  
installation of the Digital Fluorography System.  
7 Support of Extended Character Sets  
This product supports the following character sets:  
Table 4  
Basic G0 Set  
ISO-IR 6 (default)  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
8 X-Ray Angiographic Information Object Definition  
8.1 Entity Module Definitions  
The information modules for the X-Ray Angiographic devices are defined below.  
8.1.1 Media Storage Directory IOD Modules  
Table 5  
Object  
Module / key  
Reference  
Usage1  
DICOM File Meta  
Information  
M
Basic Directory  
Information Object  
Definition  
File-set Identification Module  
Directory Information Module  
M
U
Definition of Specific PATIENT keys  
M
M
M
M
Directory Records  
STUDY keys  
SERIES keys  
IMAGE keys  
1 M=Mandatory, C=Conditional, U=User option  
8.1.2 Media Storage XA IOD Modules  
Table 6  
Object  
Module / key  
Reference  
Usage1  
DICOM File Meta  
Information  
M
XA Information  
XA IOD Modules  
M
Object Definition  
1 M=Mandatory, C=Conditional, U=User option  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No. MIIXR0002EAC  
8.1.3 XA IOD Modules  
Table 7  
Information Entity  
Module  
Reference  
Usage1  
Patient  
Study  
Patient Module  
M
General Study Module  
Patient Study Module  
General Series Module  
General Equipment Module  
General Image Module  
Image Pixel Module  
Contrast/bolus Module  
Cine Module  
M
Study  
U
Series  
Equipment  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
Image  
M
M
M
M
C
C
Multi-frame Module  
Frame Pointers Module  
Mask Module  
C
Not Used  
Not Used  
Not Used  
Not Used  
Not Used  
U
C
Display Shutter Module  
Device Module  
U
U
Therapy Module  
U
X-ray Image Module  
X-ray Acquisition Module  
X-ray Collimator Module  
X-ray Table Module  
XA Positioner Module  
Overlay Plane Module  
Multi-Frame Overlay Module  
Curve Module  
M
8.5.12  
M
Not Used  
Not Used  
U
C
M
Not Used  
Not Used  
8.5.14  
U
C
C (Note)  
C/U  
U
Modality LUT Module  
VOI LUT Module  
Not Used  
SOP Common Module  
M
1 M=Mandatory, C=Conditional, U=User option  
Note : Always set when ECG data is available  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
No. MIIXR0002EAC  
8.2 DICOM File Meta Information  
8.2.1 DICOM File Meta Information of Directory IOD  
Table 8  
Attribute Name  
File Preamble  
Tag  
Type  
Attribute Description  
No Tag  
1
1
1
1
1
1
1
1
Always set  
DICOM Prefix  
No Tag  
Always set ("DICM")  
Always set  
Group Length  
(0002, 0000)  
(0002, 0001)  
(0002, 0002)  
(0002, 0003)  
(0002, 0010)  
(0002, 0012)  
File Meta Information Version  
Media Storage SOP Class UID  
Media Storage SOP Instance UID  
Transfer Syntax UID  
Always set (0x0001)  
Always set ("1.2.840.10008.1.3.10")  
Always set  
Always set ("1.2.840.10008.1.2.1")  
Always set  
Implementation Class UID  
8.2.2 DICOM File Meta Information of XA IOD  
Table 9  
Attribute Name  
File Preamble  
Tag  
Type  
Attribute Description  
Always set  
No Tag  
1
1
1
1
1
DICOM Prefix  
No Tag  
Always set ("DICM")  
Always set  
Group Length  
(0002, 0000)  
(0002, 0001)  
(0002, 0002)  
File Meta Information Version  
Media Storage SOP Class UID  
Always set (0x0001)  
Always set  
("1.2.840.10008.5.1.4.1.1.12.1")  
Media Storage SOP Instance UID  
Transfer Syntax UID  
(0002, 0003)  
(0002, 0010)  
(0002, 0012)  
(0002, 0013)  
1
1
1
3
Always set  
Always set ("1.2.840.10008.1.2.4.70")  
Always set  
Implementation Class UID  
Implementation Version Name  
Always set  
8.3 Basic Directory Information Object Definitions  
8.3.1 File-set Identification Module  
Table 10  
Attribute Name  
Tag  
Type  
Attribute Description  
Always set  
File-set ID  
(0004, 1130)  
2
- 11 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
No. MIIXR0002EAC  
8.3.2 Directory Information Module  
Table 11  
Attribute Name  
Tag  
Type  
Attribute Description  
Offset of the First Directory Record of  
the Root Directory Entity  
(0004, 1200)  
1
Always set  
Offset of the Last Directory Record of  
the Root Directory Entity  
(0004, 1202)  
1
Always set  
File-set Consistency Flag  
Directory Record Sequence  
>Offset of the Next Directory Record  
>Record In-use Flag  
(0004, 1212)  
(0004, 1220)  
(0004, 1400)  
(0004, 1410)  
(0004, 1420)  
1
Always set  
2
Always set  
1C  
1C  
1C  
Always set when condition is met  
Always set when condition is met  
Always set when condition is met  
>Offset of Referenced Lower-Level  
Directory Entity  
>Directory Record Type  
(0004, 1430)  
(0004, 1500)  
(0004, 1510)  
(0004, 1511)  
(0004, 1512)  
1C  
1C  
1C  
1C  
1C  
Always set when condition is met  
Always set when condition is met  
Always set when condition is met  
Always set when condition is met  
Always set when condition is met  
>Referenced File ID  
>Referenced SOP Class UID in File  
>Referenced SOP Instance UID in File  
>Referenced Transfer Syntax UID in  
File  
8.4 Definition of Specific Directory Records  
8.4.1 PATIENT keys  
Table 12  
Attribute Name  
Patient's Name  
Tag  
Type  
Attribute Description  
Always set except for urgent patient  
Always set  
(0010, 0010)  
(0010, 0020)  
(0010, 0030)  
(0010, 0040)  
2
1
2
2
Patient ID  
Patient's Birth Date  
Patient's Sex  
Length=0 when no entry is made  
Always set  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
No. MIIXR0002EAC  
8.4.2 STUDY keys  
Table 13  
Attribute Name  
Tag  
Type  
Attribute Description  
Study Date  
(0008, 0020)  
(0008, 0030)  
(0008, 1030)  
(0020, 000D)  
(0020, 0010)  
(0008, 0050)  
1
1
Always set  
Study Time  
Always set  
Study Description  
Study Instance UID  
Study ID  
2
Length=0 when no entry is made  
Always set  
1C  
1
Always set  
Accession Number  
2
Length=0 when no entry is made  
8.4.3 SERIES keys  
Table 14  
Attribute Name  
Modality  
Tag  
Type  
Attribute Description  
Always set ("XA")  
Always set  
(0008, 0060)  
(0020, 000E)  
(0020, 0011)  
(0008, 0080)  
(0008, 0081)  
(0008, 1050)  
1
1
1
2
2
2
Series Instance UID  
Series Number  
Always set  
Institution Name  
Always set  
Institution Address  
Performing Physician's Name  
Always set  
Length=0 when no entry is made  
- 13 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
No. MIIXR0002EAC  
8.4.4 IMAGE keys  
Table 15  
Attribute Name  
Instance Number  
Image Type  
Tag  
Type  
1
Attribute Description  
(0020, 0013)  
(0008, 0008)  
(0008, 0023)  
(0008, 0033)  
(0018, 1510)  
(0018, 1511)  
(0020, 4000)  
(0028, 0008)  
(0050, 0004)  
(0088, 0200)  
(0028, 0002)  
(0028, 0004)  
(0028, 0010)  
(0028, 0011)  
(0028, 0100)  
(0028, 0101)  
(0028, 0102)  
(0028, 0103)  
(7FE0, 0010)  
Always set  
1
Always set  
Image Date  
3
Always set  
Image Time  
3
Always set  
Positioner Primary Angle  
Positioner Secondary Angle  
Image Comments  
Number of Frames  
Calibration Image  
Icon Image Sequence  
>Samples per Pixel  
>Photometric Interpretation  
>Rows  
3
Always set [degree]  
Always set [degree]  
Length=0 when no entry is made  
Always set  
3
3
3
2
Always set  
1
Always set  
1
Always set (0x0001)  
Always set ("MONOCHROME2")  
Always set (0x0100)  
Always set (0x0100)  
Always set (0x0008)  
Always set (0x0008)  
Always set (0x0007)  
Always set (0x0000)  
Always set  
1
1
>Columns  
1
>Bits Allocated  
1
>Bits Stored  
1
>High Bit  
1
>Pixel Representation  
>Pixel Data  
1
1
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
No. MIIXR0002EAC  
8.5 XA Information Object Definisions  
8.5.1 Patient Module  
Table 16  
Attribute Name  
Patient's Name  
Tag  
Type  
Attribute Description  
Always set except for urgent patient  
Always set  
(0010, 0010)  
(0010, 0020)  
(0010, 0030)  
(0010, 0040)  
(0010, 4000)  
2
2
2
2
3
Patient ID  
Patient's Birth Date  
Patient's Sex  
Length=0 when no entry is made  
Always set  
Patient Comments  
Length=0 when no entry is made  
8.5.2 General Study Module  
Table 17  
Attribute Name  
Tag  
Type  
Attribute Description  
Always set  
Study Instance UID  
Study Date  
(0020, 000D)  
(0008, 0020)  
(0008, 0030)  
(0008, 0090)  
(0020, 0010)  
(0008, 0050)  
(0008, 1030)  
1
2
2
2
2
2
3
Always set  
Study Time  
Always set  
Referring Physician's Name  
Study ID  
Length=0 when no entry is made  
Always set  
Accession Number  
Study Description  
Length=0 when no entry is made  
Length=0 when no entry is made  
8.5.3 Patient Study Module  
Table 18  
Attribute Name  
Patient's Size  
Tag  
Type  
Attribute Description  
Length=0 when no entry is made  
Length=0 when no entry is made  
(0010, 1020)  
(0010, 1030)  
3
3
Patient's Weight  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
No. MIIXR0002EAC  
8.5.4 General Series Module  
Table 19  
Attribute Name  
Tag  
Type  
Attribute Description  
Modality  
(0008, 0060)  
(0020, 000E)  
(0020, 0011)  
(0008, 0021)  
(0008, 0031)  
(0008, 1050)  
(0008, 103E)  
1
1
2
3
3
3
3
Always set ("XA")  
Series Instance UID  
Series Number  
Series Date  
Always set  
Always set  
Always set  
Series Time  
Always set  
Performing Physician's Name  
Series Description  
Length=0 when no entry is made  
Always set  
8.5.5 General Equipment Module  
Table 20  
Attribute Name  
Manufacturer  
Tag  
Type  
Attribute Description  
Always set  
(0008, 0070)  
(0008, 0080)  
(0008, 0081)  
(0008, 1010)  
(0008, 1090)  
(0018, 1000)  
(0018, 1020)  
2
3
3
3
3
3
3
Institution Name  
Always set  
Institution Address  
Station Name  
Always set  
Always set  
Manufacturer's Model Name  
Device Serial Number  
Software Versions  
Always set  
Always set  
Always set  
8.5.6 General Image Module  
Table 21  
Attribute Name  
Tag  
Type  
2
Attribute Description  
Always set  
Image Number  
Patient Orientation  
Image Date  
(0020, 0013)  
(0020, 0020)  
(0008, 0023)  
(0008, 0033)  
(0008, 0008)  
(0008, 0022)  
(0008, 0032)  
(0020, 4000)  
2C  
2C  
2C  
3
Always Length=0  
Always set  
Image Time  
Always set  
Image Type  
Always set  
Acquisition Date  
Acquisition Time  
Image Comments  
3
Always set  
3
Always set  
3
Length=0 when no entry is made  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
No. MIIXR0002EAC  
8.5.7 Image Pixel Module  
Table 22  
Attribute Name  
Samples per Pixel  
Photometric Interpretation  
Rows  
Tag  
Type  
Attribute Description  
(0028, 0002)  
(0028, 0004)  
(0028, 0010)  
(0028, 0011)  
(0028, 0100)  
(0028, 0101)  
(0028, 0102)  
(0028, 0103)  
(7FE0, 0010)  
1
1
1
1
1
1
1
1
1
Always set (0x0001)  
Always set ("MONOCHROME2")  
Always set (0x0400 or 0x0200)  
Always set (0x0400 or 0x0200)  
Always set (0x0008)  
Always set (0x0008)  
Always set (0x0007)  
Always set  
Columns  
Bits Allocated  
Bits Stored  
High Bit  
Pixel Representation  
Pixel Data  
Always set  
8.5.8 Contrast/Bolus Module  
Table 23  
Attribute Name  
Tag  
Type  
Attribute Description  
Length=0 when no entry is made  
Length=0 when no entry is made  
Length=0 when no entry is made  
Length=0 when no entry is made  
Contrast/Bolus Agent  
Contrast/Bolus Route  
Contrast/Bolus Volume  
Contrast Flow Rate(s)  
(0018, 0010)  
(0018, 1040)  
(0018, 1041)  
(0018, 1046)  
2
3
3
3
8.5.9 Cine Module  
Table 24  
Attribute Name  
Tag  
Type  
Attribute Description  
Frame Time  
(0018, 1063)  
1C  
Always set  
8.5.10 Multi-frame Module  
Table 25  
Attribute Name  
Number of Frames  
Tag  
Type  
Attribute Description  
Always set  
(0028, 0008)  
(0028, 0009)  
1
1
Frame Increment Pointer  
Always set (0x00181063)  
- 17 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
No. MIIXR0002EAC  
8.5.11 X-ray Image Module  
Table 26  
Attribute Name  
Frame Increment Pointer  
Image Type  
Tag  
Type  
1C  
1
Attribute Description  
(0028, 0009)  
(0008, 0008)  
(0028, 1040)  
(0028, 0002)  
(0028, 0004)  
(0028, 0100)  
(0028, 0101)  
(0028, 0102)  
(0028, 0103)  
(0008, 1140)  
Always set (0x00181063)  
Always set  
Pixel Intensity Relationship  
Samples per Pixel  
Photometric Interpretation  
Bits Allocated  
1
Always set ("DISP" or "LIN")  
Always set (0x0001)  
Always set ("MONOCHROME2")  
Always set (0x0008)  
Always set (0x0008)  
Always set (0x0007)  
Always set  
1
1
1
Bits Stored  
1
High Bit  
1
Pixel Representation  
Reference Image Sequence  
1
1C  
Not set when Image type(0008,0008)  
Value 3 is "SINGLE PLANE"  
>Reference SOP Class UID  
(0008, 1150)  
(0008, 1155)  
1C  
1C  
Always set when Reference Image  
Sequence is present  
>Reference SOP Instance UID  
Always set when Reference Image  
Sequence is present  
8.5.12 X-ray Acquisition Module  
Table 27  
Attribute Name  
Tag  
Type  
2
Attribute Description  
Always set [kV]  
KVP  
(0018, 0060)  
(0018, 1155)  
(0018, 1151)  
(0018, 1150)  
(0018, 1154)  
(0018, 1162)  
(0018, 1147)  
(0018, 1149)  
(0018, 1164)  
Radiation Setting  
1
Always set  
X-ray Tube Current  
Exposure Time  
2C  
2C  
3
Always set [mA]  
Always set [msec]  
Always set [msec]  
Always set [mm]  
Average Pulse Width  
Intensifier Size  
3
Field of View Shape  
Field of View Dimension(s)  
Imager Pixel Spacing  
3
Always set("ROUND ")  
Always set [mm]  
3
3
Always set [mm]  
- 18 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
No. MIIXR0002EAC  
8.5.13 XA Positioner Module  
Table 28  
Attribute Name  
Tag  
Type  
Attribute Description  
Distance Source to Detector  
Estimated Radiographic Magnification  
Factor  
(0018, 1110)  
(0018,1114)  
3
3
Always set [mm]  
Always set  
Positioner Motion  
(0018, 1500)  
(0018, 1510)  
(0018, 1511)  
2C  
2
Always set ("STATIC")  
Always set [degree]  
Always set [degree]  
Positioner Primary Angle  
Positioner Secondary Angle  
2
8.5.14 Curve Module  
Table 29  
Attribute Name  
Curve Dimensions  
Number of Points  
Tag  
Type  
1
Attribute Description  
(5000, 0005)  
(5000, 0010)  
(5000, 0020)  
(5000, 0030)  
(5000, 0103)  
(5000, 0110)  
(5000, 0112)  
(5000, 0114)  
(5000, 3000)  
Always set  
Always set  
Always set  
Always set  
Always set  
Always set  
Always set  
Always set  
Always set  
1
Type of Data  
1
Axis Units  
3
Data Value Representation  
Curve Data Descriptor  
Coordinate Start Value  
Coordinate Step Value  
Curve Data  
1
1C  
1C  
1C  
1
Note : This module is set only if ECG data is available.  
8.5.15 VOI LUT Module  
Table 30  
Attribute Name  
Window Center  
Window Width  
Tag  
Type  
3
Attribute Description  
(0028, 1050)  
(0028, 1051)  
Always set  
Always set  
1C  
8.5.16 SOP Common Module  
Table 31  
Attribute Name  
Tag  
Type  
Attribute Description  
SOP Class UID  
(0008, 0016)  
(0008, 0018)  
1
1
Always set  
Always set  
SOP Instance UID  
E
- 19 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       

Teledyne Marine Instruments HCM 300 User Manual
Transition Networks TV Converter Box AR CF 02 User Manual
Triax Satellite TV System DVB 75SI User Manual
Troy Bilt Trimmer YM1500 User Manual
Ultratec DVD Player DMS 100 User Manual
Univex Blower 358799370 User Manual
Vanguard Heating Indoor Fireplace VSGF28PVA User Manual
ViewSonic Digital Photo Frame DPG807BK User Manual
ViewSonic Projector PJD5112 User Manual
Volvo Automobile S70 User Manual