Toshiba Network Card RKP004Z User Manual

E6581323  
LCD Remote Keypad  
Instruction Manual  
RKP004Z  
Notice  
1. Please see to it that this instruction manual reaches the actual user of the LCD remote  
keypad without fail.  
2. Be sure to read this instruction manual carefully before installing and using the LCD remote  
keypad. After reading the manual, be sure to store it.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Optional products  
The products listed below are optionally available. Purchase these cables and  
attachments separately.  
Product  
Model number  
Product  
Model number  
CAB0071  
(1m)  
CNT001Z  
Interconnect cable  
Interconnect cable  
Interconnect cable  
Interconnect cable  
Connector  
CAB0073  
(3m)  
SBP006Z  
SBP007Z  
-
IP54 attachment  
CAB0075  
(5m)  
IP65 attachment  
-
CAB00710  
(10m)  
You can install the LCD remote keypad to the inverter or operate the inverter by  
remote control combining optional products.  
For details, refer to “2. Installing the LCD remote keypad. ”  
«Installation on an inverter (no optional products required)»  
RKP004Z  
«Installation on a board»  
+
+
RKP004Z  
SBP006Z  
CAB0††††  
«Installation on a board (protective structure)»  
+
+
+
+
+
RKP004Z  
SBP006Z  
CNT001Z  
SBP007Z  
CAB0††††  
«Remote control»  
RKP004Z  
CAB0††††  
: 071, 073, 075, 0710  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety precautions  
On the inverter and in its instruction manual, important information is contained for  
preventing injuries to users, damages to assets, and for proper use of the device.  
Read the instruction manual attached to the inverter along with this instruction manual  
to completely understand the safety precautions, the symbols and indications shown  
below. Please adhere to the contents of these manuals at all times.  
Explanation of markings  
Marking  
Warning  
Caution  
Meaning of marking  
Indicates that errors in operation may lead to death or serious injury.  
Indicates that errors in operation may lead to injury (*1) to people or that these  
errors may cause damage to physical property. (*2)  
(*1) Such things as injury, burns or shock that will not require hospitalization or long  
periods of outpatient treatment.  
(*2) Physical property damage refers to wide-ranging damage to assets and materials.  
Meanings of symbols  
Marking  
Meaning of marking  
Indicates prohibition (Don't do it).  
What is prohibited will be described in or near the symbol in either text or picture  
form.  
Indicates something mandatory (must be done).  
What is mandatory will be described in or near the symbol in either text or picture  
form.  
Indicates warning.  
What is warned will be described in or near the symbol in either text or picture  
form.  
Indicates caution.  
What the caution should be applied to will be described in or near the symbol in  
either text or picture form.  
Limitation of use  
Safety precaution  
Never use this unit with any device other than TOSVERT series inverters. Doing so may  
cause an accident.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety precautions  
Handling in general  
Warning  
Never disassemble, modify or repair the product.  
Disassembling the product may cause electric shocks, fire or injuries.  
For repairs, call your sales/repair agency.  
Never  
Disassem  
ble  
Do not put or insert foreign objects such as waste cable, bars, or wires into the  
product.  
It may lead to electric shocks or fire.  
Do not splash water over the product, and do not wipe the body with a wet cloth.  
It may lead to electric shocks or fire.  
Prohibited  
Turn off input power before wiring.  
Wait at least 15 minutes and check to make sure that the charge lamp (on the  
inverter unit) is no longer lit.  
Turn off the power immediately in case of any abnormalities such as smoke,  
smell or abnormal noise.  
Mandatory  
Neglect of these conditions may lead to fire.  
For repairs, call your sales/repair agency.  
Transportation and installation  
Warning  
Do not install or operate the inverter if it is damaged or any part of it is missing.  
Operating a defective inverter may lead to electric shocks or fire.  
For repairs, call your sales/repair agency.  
Do not put any flammable material near the product.  
It may catch fire due to the product sparking in the case of a malfunction.  
Electrical construction work must be done by a qualified expert.  
Connection of input power by someone who does not have expert knowledge  
may result in fire or electric shock.  
Prohibited  
Operate under the environmental conditions prescribed in the instruction  
manual.  
Operations under any other conditions may result in malfunction.  
An emergency stop device must be installed that fits with system specifications  
(e.g. shut off input power then engage mechanical brake).  
Operation cannot be stopped immediately by the inverter or Remote Keypad  
alone, thus risking an accident or injury.  
Mandatory  
Use the Toshiba-specified cable for connecting this optional unit. (Refer to page  
.)  
The use of any other option may result in an accident.  
Caution  
Do not install the product in any place subject to vibrations or it may fall.  
This may lead to the product falling and causing injury.  
Prohibited  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety precautions  
Operations  
Warning  
Do not apply a dropping shock or other physical shocks.  
Otherwise, damage or malfunction will result.  
Do not pull on the cable and connector  
It may cause damage or error.  
Even if this product is deactivated by an unusual event such as tripping, an  
operating error, power outage, etc. do not bring any regions of your body into  
contact with the inverter terminals when power is supplied to the inverter.  
Contact during the power-on status of the inverter can result in electric shock.  
Use an additional safety device with your inverter or system to prevent a  
serious accident due to the unit malfunctions. Usage without an additional  
safety device may cause an accident.  
Prohibited  
Make sure to check that the parameter data from this product is not  
accidentally copied to the wrong inverter.  
Mandatory  
Usage with wrong parameter may result in an accident.  
Caution  
Set up “Communication error trip time (F803, F804, see the inverter instruction  
manual for details)” to stop the inverter when Remote Keypad is deactivated by  
an unusual event such as tripping, an operating error, power outage, failure,  
etc. Deactivated Remote Keypad may cause an accident, if the  
Mandatory  
“Communication error trip time” is not properly set up.  
Disposal  
Caution  
If you dispose off this unit, have it done by a specialist in industrial waste  
disposal*. Improper disposal may result in explosion of capacitors or produce  
noxious gases, resulting in injury.  
(*) Persons who specialize in the processing of waste and known as “Industrial  
Waste Product Collectors and Transporters” or “Industrial Waste Disposal  
Persons.” If the collection, transport and disposal of industrial waste is done by  
someone who is not licensed for that job, it is a punishable violation of the law  
(Laws in regard to cleaning and processing of waste materials).  
Mandatory  
Notes on operations  
Notes  
Avoid installing in a place where ambient temperature or/and humidity change  
sharply.  
Keep the interconnect cable separate from the power cable of the inverter to  
prevent the inverter from malfunctioning due to electromagnetic noise.  
It is recommended to install the unit on the panel board of a cabinet if it is used  
as a remote operation panel. Improperly installed units may result in damage  
and malfunction.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
1. Names and functions······················································································ 1-1  
2. Installing the LCD remote keypad ································································· 2-1  
2. 1 Installing the remote keypad to the inverter········································ 2-1  
2. 2 Installing the remote keypad to the board (optional)·························· 2-2  
2. 3 Remote control (optional)······································································ 2-3  
3. Setting to be made when turning on the unit for the first time·················· 3-1  
4. About available modes ··················································································· 4-1  
5. Operation in Top View Mode·········································································· 5-1  
5. 1 Setting a panel operation frequency ···················································· 5-1  
5. 2 Using an EASY key function·································································· 5-2  
5. 3 Selecting a language to be displayed··················································· 5-4  
5. 4 Performing jog run ················································································· 5-5  
5. 5 Emergency stop/reset operation··························································· 5-6  
6. Operation in Parameter Setup Mode····························································· 6-1  
6. 1 Searching for the change histories of parameters  
(History function)···················································································· 6-1  
6. 2 Setting a basic parameter······································································ 6-2  
6. 3 Setting an extended parameter ····························································· 6-3  
6. 4 Searching for parameters whose settings were changed  
(Search for changed settings) ····························································· 6-4  
7. Operation in Status Monitor Mode ································································ 7-1  
7. 1 Displaying details of an item monitored ·············································· 7-2  
8. Operation in a copy function ········································································· 8-1  
8.1 Copy to LCD ····························································································· 8-2  
8.2 Copy to inverter ······················································································· 8-3  
8.3 Confirm a memory information······························································ 8-4  
9. List of function key functions········································································ 9-1  
10. Specifications································································································ 10-1  
11. Before making a service call······································································ 11-1  
12. Warranty······································································································· 12-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Names and functions  
(2) (3) (4) (5)  
(1)  
(6)  
(7)  
(9)  
(8)  
(10)  
(1) LCD panel  
For an explanation of windows displayed, see the next page.  
(2) to (5) [F1] to [F4] function keys  
The function of each function key varies depending on the window currently  
displayed.  
Refer to the next page and “8. List of function key functions”  
(6) [ESC] key  
Each time this key is pressed, modes change from one to another. Also, pressing  
this key brings you back to the window one level higher in the window hierarchy.  
(7) [FWD/REV] key  
Each time this key is pressed, the direction of operation changes between forward  
run and reverse run.  
(To use this key, parameter settings need to be changed. Refer to page 1-3.)  
(8) [RUN] key  
Starts operation.  
(To use this key, parameter settings need to be changed. Refer to page 1-3.)  
(9) [STOP/RESET] key  
Stops operation.  
(To use this key, parameter settings need to be changed. Refer to page 1-3.)  
In case the inverter has tripped, pressing this key twice in a row resets the inverter.  
* If multiple commands are entered by pressing the three keys [F2], [F3] and [F4] or  
[ESC], [FWD] and [RUN] in rapid succession, a stop command will be issued  
instead to stop operation.  
(10) Control dial *1  
In a menu window, turn the dial clockwise or counterclockwise to select a menu item  
(the item selected is highlighted) and press the dial to confirm the menu item  
selected.  
Turn the dial clockwise (+) to select an item that follows the item currently selected.  
Turn the dial counterclockwise (-) to select an item that precedes the item currently  
selected.  
Selecting a menu item by turning the dial clockwise or counterclockwise and confirm  
the item selected by pressing the dial are referred to as “select/confirm an item.”  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Names and functions  
In a value setting window, turn the dial clockwise or counterclockwise to increment or  
decrement the value displayed, and press the dial to confirm the value specified.*2  
Turn the dial clockwise (+) to increment the value.  
Turn the dial counterclockwise (-) to decrement the value.  
Turning the dial clockwise or counterclockwise to increment or decrement the value  
displayed and pressing the dial to confirm the value specified are referred to as  
“specify/confirm a value.”  
*1: When the control dial is pressed, it performs the same function as the [ENT] key  
on the inverter’s main operation panel.  
*2: Some settings are executed only by tuning the control dial.  
LCD panel  
This section explains the features of windows available, using the top window of  
Status Monitor Mode as an example.  
(1)  
(2)  
Status Monitor Mode  
Real-time information  
(3)  
Rotative direction  
Frequency reference  
Output current  
FWD  
60.0Hz  
90%  
(4)  
Input voltage  
99%  
Output voltage  
99%  
Top  
Prm  
(5)  
(6)  
(1) Displays the mode currently selected.  
(2) Displays the operating status of the inverter in a graphical symbol.  
(rotating)  
: In operation  
: Operation impossible (While the frequency is set at 0Hz, the  
[RUN] key is pressed.)  
EOFF (blinking)  
: Waiting for emergency stop operation  
(3) Displays the title or status of the window.  
(4) Displays settings both in a menu form and numerically, or a list of various kinds of  
information.  
(5) Displays the function assigned to each function key in an abbreviation or graphical  
symbol.  
The abbreviations and graphical symbols in the window correspond to the [F1] to  
[F4] keys, respectively starting from the left.  
Top  
:
In this example, pressing the [F1] key displays the Top View Mode window.  
: In this example, pressing the [F2] key displays the previous window.  
: In this example, pressing the [F3] key displays the next window.  
Prm : In this example, pressing the [F4] key displays the Parameter Setting Mode  
window.  
Refer to “8. List of function key functions”  
(6) Graphical symbols displayed vary depending on whether there are windows that  
precede or follow the current window.  
: There are windows that precede and/or follow the current window.  
: There is no window that precedes or follows the current window.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Names and functions  
About the change of parameter settings  
By default, the inverter is set with parameters to the mode in which it controls the  
operation of the machine via a terminal board. Moreover, the inverter is set so that  
the switching between forward run and reverse run cannot be performed using its  
operation panel.  
To operate the inverter using this unit, parameter settings need to be changed, as  
described below.  
Parameter CMOd (Command input mode) =1 (Pane/LCD-option)  
Parameter FMOd (Frequency input mode 1)=4 (Pane/LCD-option)  
Parameter Fr (Panel FWD/REV selection) =2 (Forward (switchable)),  
3 (Reverse (switchable))  
This change of parameter settings makes it possible to start operation using the  
[RUN] key, to stop operation using the [STOP/RESET] key, and to switch between  
forward run and reverse run using the [FWD/REV] key.  
Furthermore, it allows you to set an operation frequency using the control dial.  
Refer to “5.1 Setting a panel operation frequency.”  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Installing the LCD remote keypad  
The LCD remote keypad can be installed on the inverter and on the board (optional).  
Using this LCD remote keypad along with a dedicated interconnect cable makes it  
possible to operate the inverter by remote control (optional).  
2.1 Installing the remote keypad to the inverter  
Turn off the inverter, and then follow these steps.  
1 Remove the serial RS485 port cover  
from the inverter’s main operation  
panel.  
To detach the cover, wrench it open using  
a flat-blade screwdriver or any other  
flat-tipped tool.  
2 Mount the remote keypad on the  
inverter’s main operation panel.  
Insert the connector on the remote  
keypad into the RS485 port while pushing  
in the lock knobs, and then release the  
lock knobs to secure the remote keypad.  
3 Make sure the remote keypad is fixed  
securely to the inverter.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Installing the LCD remote keypad  
2.2 Installing the remote keypad to the board (optional)  
The remote keypad can be mounted on a board by means of an IP54 attachment  
(optional).  
If an IP65 attachment (optional) is used in combination with an IP54 attachment, the  
remote keypad can be installed where it may be splashed with water.  
Warning  
Never connect the unit to any inverter other than a VF-AS1/PS1 series  
inverter or any communication device. Do not use any cable other than  
an optional interconnect cable designed specifically for the unit.  
If the correct cable was not used, this might cause the unit to break down  
and result in an electric shook or fire.  
Prohibited  
Turn off the inverter, as shown in the figure below.  
Tapping screws (4 pieces)  
Used to secure the attachment.  
Make a hole in the board, as shown in  
the figure below.  
115  
5.5  
104  
5.5  
4-Ф3.5  
IP54 attachment  
(optional)  
Remote keypad  
Dedicated interconnect cable  
(optional) *  
* The pin configuration of the dedicated  
interconnect cable is different from that of  
any other commercially available cable.  
Therefore, be sure to use the dedicated  
interconnect cable.  
IP65 attachment (optional)  
Used to be attached to the IP54 attachment  
*Leave a space of 45mm or more  
for the interconnect cable.  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Installing the LCD remote keypad  
2.2 Remote control (optional)  
Connecting the remote keypad to the inverter unit with a dedicated interconnect cable  
and a connector (optional) makes it possible to operate the inverter from a distant  
point up to 5m from it.  
Warning  
Never connect the unit to any inverter other than a VF-AS1/PS1 series  
inverter or any communication device. Do not use any cable other than  
an optional interconnect cable designed specifically for the unit.  
If the correct cable was not used, this might cause the unit to break down  
and result in an electric shook or fire.  
Prohibited  
Turn off the inverter, as shown in the figure below.  
<Inverter unit>  
*Leave a space of 60mm or more  
for the interconnect cable.  
Connector (optional)  
< Remote keypad >  
Dedicated interconnect  
cable (optional) *  
Serial RS485  
connector (2-wire)  
* The pin configuration of the dedicated interconnect  
cable is different from that of any other commercially  
available cable.  
Therefore, be sure to use the dedicated interconnect  
cable.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Setting to be made when turning on the unit for the first time  
When the unit is turned on at the first time after purchase, the Language Selection  
window shown below appears on the LCD panel. In this window, select the language  
you want to display on the screen.  
1 The Language Selection window appears on  
Language selection  
the screen.  
English  
This window appears only when the unit is turned  
on at the first time after purchase.  
Deutsch  
Portuguese  
2 Select the desired language using the control  
Language selection  
English  
dial and push the dial.  
(In this example, English is selected. There is no  
need to select/confirm the language.)  
Deutsch  
Portuguese  
3 The Startup window is displayed and soon  
インバータ⇒パネル  
replaced by the top window of Top View Mode.  
CONNECTION IN PROGRESS  
* V1.1 IE04  
*: This window shows the  
version of the installed  
software. The contents of  
the window may be  
somewhat different from  
those of your LCD panel.  
Top View Mode  
FWD 0.0Hz  
STOP  
0.0  
Hz  
Quick  
Lng  
---  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. About available modes  
The LCD remote keypad offers the following three modes, just as with the inverter’s  
main operation panel.  
(1) Top View Mode  
When the remote keypad is turned on, it enters this mode first.  
The top window displays the operating status.  
In this mode, you can set a panel operation frequency, use a function key as the  
EASY key, and so on.  
Refer to “5. Operation in Top View Mode.”  
(2) Parameter Setup Mode  
This mode allows you to set parameters.  
Refer to “6. Parameter Setup Mode.”  
(3) Status Monitor Mode  
This mode allows you to monitor various kinds of statuses and information, such  
as the operating status of the inverter and information on the terminal board.  
Refer to “7. Operation in Status Monitor Mode.”  
The figures below show the top windows of these modes.  
To change from one mode to another, press the [ESC] key.  
Top View Mode  
FWD 60.0 Hz  
STOP  
0.0  
Hz  
ESC  
ESC  
Lng  
Quick  
---  
Top View Mode  
Status Monitor Mode  
Real-time information  
Parameter Setup Mode  
Category Selection  
Rotative direction  
FWD  
History function  
Frequency reference  
Output current  
Input voltage  
60.0Hz  
0%  
Basic Parameters  
Extended Parameters  
Changed Parameters  
99%  
0%  
Output voltage  
Top  
Mon  
Top  
Prm  
Status Monitor Mode  
Parameter Setup Mode  
* When Quick mode is selected  
with the EASY key, other  
windows are displayed.  
ESC  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Operation in Top View Mode  
When the remote keypad is turned on, it enters this mode first, which allows you to  
monitor the operating status, set an operation frequency, use a function key as the  
EASY key, and switch between languages.  
When Panel Jog Run is selected, a jog run frequency also can be specified in this  
mode.  
Display of commands Display of  
Explanation of the top window  
• Display of commands executed:  
“FWD” or “REV” is displayed to indicate the  
direction of rotation.  
executed  
operating status  
Top View Mode  
FWD 60.0 Hz  
RUN  
The operation frequency is displayed in the form  
of “††Hz.”  
• Display of operating status:  
“RUN” is displayed during operation.  
“STOP” is displayed during a stop.  
“Trip” is displayed in the event of tripping.  
• Display of output frequency:  
60.0  
Hz  
Overheat alarm  
Lng  
---  
Quick  
F1  
F2  
The operation frequency is displayed in the form of  
††. Hz.”  
Display of output frequency  
Display of alarm/tripping  
• Display of alarm/tripping:  
If an error or tripping occurs, an error or trip code is displayed.  
• Display of error/tripping message:  
Display of  
error/tripping  
message  
If an error or tripping occurs, an error or trip message is displayed.  
Functions of function keys  
F1  
: Switches between Quick mode and Standard Setting mode.  
F2  
: Brings you to the Language selection window.  
5.1 Setting a panel operation frequency  
When Frequency input mode1 (parameter FMOd=4) as a frequency setting mode, an  
operation frequency can be set with the remote keypad.  
1 Press the control dial.  
Basic Parameters  
The panel frequency window appears.  
The current operation frequency setting is displayed  
at the center of the window.  
FC  
Panel frequency  
Output frequency  
0.0Hz  
The current output frequency is displayed in the  
upper right section of the window.  
The minimum allowable frequency (min) and the  
maximum allowable frequency (max) are displayed  
at the bottom of the window.  
0.0Hz  
min=0.0  
max=60.0  
×1000  
×100  
×10  
×1  
F1  
F2  
F3  
F4  
Functions of function keys  
The functions keys allow you to select the position or decimal place of each figure  
(operation frequency) you want to increment or decrement with the control dial.  
F1  
: Selects the position of hundreds.  
F2  
: Selects the position of tens.  
F3  
F4  
: Selects the position of ones.  
: Selects the first decimal place.  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Operation in Top View Mode  
2 After selecting the position of a figure you want  
to change, specify/confirm another figure with  
the control dial.  
Basic Parameters  
FC  
Panel frequency  
(In this example, a frequency of 30.0Hz is specified.)  
Output frequency  
0.0Hz  
Functions of function keys  
30.0Hz  
The functions keys allow you to select the position  
or decimal place of each figure (operation  
frequency) you want to increment or decrement with  
the control dial.  
min=0.0  
max=60.0  
×1000  
×100  
×10  
×1  
F1  
F4  
F2  
F3  
F1  
: Selects the position of hundreds.  
F2  
: Selects the position of tens.  
F3  
: Selects the position of ones.  
F4  
: Selects the first decimal place.  
When you confirm the frequency specified, the screen goes back to the top window  
of Top View Mode.  
To change the frequency during operation  
Press the control dial during operation to display the operation panel operation  
frequency menu and turn the control dial to change the setting.  
5.2 Using an EASY key function  
The [F1] function key can be used as a substitute for the EASY key on the inverter’s  
main operation panel. When the name of the function assigned to the [F1] key is  
displayed in the lower left corner of the window, the [F1] key can be used as the EASY  
key.  
“Quick”  
“Panel”  
: Function of switching between Quick  
mode and Standard Setting mode  
(parameter F750=0)  
: Function of switching between Operation  
Panel and Remote  
Top View Mode  
FWD 60.0 Hz  
STOP  
0.0  
Hz  
(parameter F750=2)  
(When used with a VF-AS1 inverter)  
Lng  
---  
Quick  
“Loc/Rem” : Function of switching between Local and  
Remote  
Quick  
(parameter F750=2)  
Panel (When used with a VF-AS1  
inverter)  
(When used with a VF-PS1 inverter)  
“Update” : Function of updating the Peak/Minimum  
Hold setting  
Loc/Rem (When used with a VF-PS1  
inverter)  
(parameter F750=3)  
* The shortcut key function (parameter F750=1)  
cannot be used. Even if the parameter is so set, the  
name of the function is not displayed on the screen.  
5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Operation in Top View Mode  
(1) Function of switching between Quick mode and Standard Setting mode  
<Standard Setting mode selected when power is turned on (parameter PSEL=0)>  
When power is turned on, ”Quick” is displayed. (If the [F1] key is not pressed.)  
When the unit enters Parameter Setup Mode in this situation, the ordinary top  
window of Parameter Setup Mode appears.  
If the [F1] key is pressed while “Quick” is displayed, “Quick” is switched from  
Quick  
normal to reverse video “  
”. (If the [F1] key is pressed.)  
When the unit enters Parameter Setup Mode in this situation, the Quick mode  
window appears instead of the top window of Parameter Setup Mode.  
<Quick mode selected when power is turned on (parameter PSEL=1)>  
Quick  
When power is turned on, “  
” is displayed in reverse video. (If the [F1] key  
is not pressed.)  
When the unit enters Parameter Setup Mode in this situation, the Quick mode  
window appears instead of the top window of Parameter Setup Mode.  
If the [F1] key is pressed when “  
” is displayed in reverse video, “Quick” is  
Quick  
switched from reverse to normal video. (If the [F1] key is pressed.)  
When the unit enters Parameter Setup Mode in this situation, the ordinary top  
window of Parameter Setup Mode appears.  
<Always Quick mode (parameter PSEL=2)>  
” is displayed in reverse video.  
Quick  
When the unit enters Parameter Setup Mode in this situation, the Quick mode  
window appears instead of the top window of Parameter Setup Mode.  
* In this situation, the [F1] key is inoperative.  
(2) Operation Panel and Remote (When used with a VF-AS1 inverter)  
“Panel” is displayed. (If the [F1] key is not pressed.)  
In this situation, operation can be performed by remote control by means of the  
terminal board.  
If the [F1] key is pressed while “Panel” is displayed, “Panel” is switched from  
Panel  
normal to reverse video “  
”. (If the [F1] key is pressed.)  
In this situation, operation can be performed using keys on the remote keypad.  
There is no need to switch to Panel Operation mode by changing parameter  
settings.  
* The switching between operation modes cannot be done during operation.  
(3) Operation Panel and Remote (When used with a VF-PS1 inverter)  
Rem  
” is displayed. (If the [F1] key is not pressed.)  
“Loc/  
In this situation, operation can be performed by remote control by means of the  
terminal board.  
If the [F1] key is pressed while “Panel” is displayed, “Loc/ Rem ” is switched from  
normal to reverse video “ Loc /Rem”. (If the [F1] key is pressed.)  
In this situation, operation can be performed using keys on the remote keypad.  
There is no need to switch to Local Operation mode by changing parameter  
settings.  
* The switching between operation modes cannot be done during operation.  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Operation in Top View Mode  
(4) Peak/Minimum Hold setting  
“Update” is displayed. (If the [F1] key is not pressed.)  
The instant the [F1] key is pressed in this situation, a measurement for peak  
hold/minimum hold starts. When the [F1] key is pressed, “  
in reverse video. (If the [F1] key is pressed.)  
” is displayed  
Update  
5.3 Selecting a language to be displayed  
A language to be displayed on the screen can be selected.  
In this window, the language selected when turning on the remote keypad for the first  
time can also be changed to the other language.  
Note) When an application CPU version of VFAS1 is less than V104, you cannot choose  
it other than English and Japanese.  
1 Press the [F2] (Lng) key.  
The Language selection window appears on the  
Language selection  
English  
V
screen.  
Select/confirm the desired language with the  
control dial.  
Deutsch  
Portuguese  
Functions of function keys  
Top  
F1  
F1  
: Brings you to the Top View Mode.  
2 Select/confirm the desired language with the  
control dial.  
Language selection  
English  
(In this example, Japanese is selected.)  
V
Deutsch  
Functions of function keys  
Portuguese  
F1  
: Brings you to the Top View Mode.  
Top  
F1  
5-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Operation in Top View Mode  
5.4 Performing jog run  
When Panel Jog Run is selected (parameter F262=1, CMOd=1), “JOG” is displayed in  
the lower right corner of the window. When “JOG” is displayed, jog run can be  
performed using the [F4] key.  
The switching to jog run cannot be performed during operation. When switching to Jog  
Run mode, operation has to be stopped temporarily.  
Top View Mode  
FWD 60.0 Hz  
STOP  
0.0  
Hz  
Lng  
JOG  
Quick  
1 Press the [F4] key to carry out jog run.  
The jog run frequency is displayed on the screen.  
(In this example, the operation frequency is set at  
5.0Hz.)  
Top View Mode  
FWD 60.0 Hz  
JOG  
Operation continues as long as the [F4] key is  
pressed, and it stops when the [F4] key is  
released.  
5.0  
Hz  
Lng  
JOG  
F4  
Quick  
F1  
F2  
Functions of function keys  
F1  
: Switches between Quick mode and Standard  
Setting mode.  
F2  
: Brings you to the Language selection window.  
F4  
: Executes a jog run command.  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Operation in Top View Mode  
5.5 Emergency stop/reset operation  
To make an emergency stop or to reset the inverter, follow these steps. An emergency  
stop can be made when operation is performed with the terminal board (parameter  
CMOd=0, 2, 3 or 4).  
1 Press the [STOP/RESET] key, which displays  
Top View Mode  
FWD 60.0 Hz  
EOFF  
RUN  
the blinking code “EOFF” in the upper right  
corner of the window.  
60.0  
Hz  
Emergency stop?  
Lng  
---  
Quick  
2 Then press the [STOP/RESET] key again.  
The Emergency Stop window appears and the  
blinking code “E” is displayed.  
Top View Mode  
FWD 60.0 Hz  
Trip  
E
Emergency stop  
Lng  
---  
Quick  
3 Then press the [STOP/RESET] key again.  
The Trip window appears and the blinking code  
“CLr” is displayed in it.  
Top View Mode  
FWD 60.0 Hz  
Trip  
CLr  
Trip reset? (STOP-Key)  
Lng  
---  
Quick  
4 Last of all, press the [STOP/RESET] key once  
again to reset the inverter.  
5-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Operation in Parameter Setup Mode  
In this mode, you can set basic parameters and extended parameters.  
This mode also allows you to use the history function (inverter’s parameter ) and  
the changed parameter search function (inverter’s parameter ) easily by simply  
selecting the desired function from a menu.  
Parameter Setup Mode  
Category Selection  
History function  
Basic Parameters  
Functions of function keys  
Extended Parameters  
F1  
: Brings you to the Top View Mode.  
Changed Parameters  
F4  
: Brings you to the Status Monitor Mode.  
Top  
Mon  
F1  
F4  
When Quick mode is selected  
The window shown in the figure at right appears  
when Quick mode is selected using the EASY key  
function.  
This window displays the parameter currently  
selected for Quick mode.  
Parameter Setup Mode  
Quick mode  
AU4  
:Automatic function set  
:V/f control mode  
Pt  
FH  
:Maximum frequency  
:Acceleration time 1  
:Deceleration time 1  
ACC  
DEC  
Top  
Functions of function keys  
Mon  
F4  
F1  
: Brings you to the Top View Mode.  
F1  
F2  
F3  
F2  
: Displays the previous window.  
F3  
: Displays the next window.  
F4  
: Brings you to the Status Monitor Mode.  
6.1 Searching for the change histories of parameters  
(History function)  
The change histories of up to 5 parameters can also be displayed in a list form in order  
of novelty.  
1 Select/confirm “History function” using the  
Parameter Setup Mode  
control dial.  
History function  
vL  
:Base frequency 1  
Change histories are displayed in a list form in  
order of novelty.  
If the number of change histories exceed 5,  
change histories except the 5 latest ones are  
deleted in the order in which changes were made.  
CMOd :Command input mode  
----  
----  
----  
:There is no history  
:There is no history  
:There is no history  
Top  
F1  
Functions of function keys  
F1  
: Brings you to the Top View Mode.  
In this window, settings can be changed.  
Pressing the control dial displays the Parameter Setting window, in which you can  
change settings as required.  
For the steps to be followed, see the following pages.  
6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Operation in Parameter Setup Mode  
6.2 Setting a basic parameter  
When Quick mode is selected using the EASY key function, skip step 1.  
Go straight to step 2.  
1 Select/confirm “Basic parameters” using the  
Parameter Setup Mode  
control dial.  
Basic Parameters  
:Automatic acc/dec  
The Basic Parameters window appears.  
AU1  
AU2  
AU4  
:Automatic torque boost  
:Automatic function set  
Functions of function keys  
CMOd :Command input mode  
FMOd :Frequency input mode 1  
Top  
F1  
: Brings you to the Top View Mode.  
: Displays the previous window.  
: Displays the next window.  
F2  
F3  
F1  
F2  
F3  
2 Select/confirm the parameter setting you want  
to change, using the control dial.  
(Ex. Select/confirm “Command input mode”  
and “Base frequency 1.”  
The Parameter Setting window appears.  
If the setting selected is changed by selecting a  
menu item, the menu item selected is highlighted  
and marked with a checkmark.  
If the setting selected is  
changed by selecting a menu  
item  
Basic Parameters  
CMOd  
Command input mode  
Functions of function keys  
F2  
: Displays the previous window.  
0 :Terminal  
F3  
: Displays the next window.  
1 :Panel / LCD-option  
2 :RS485-2wire  
3 :RS485-3wire  
F2  
F3  
If the setting selected is changed by specifying a  
value, the value specified is displayed. In addition,  
the minimum allowable value (min) and the  
maximum allowable value (max) are also  
displayed at the bottom of the window.  
If the setting selected is  
changed by specifying a  
value  
Basic Parameters  
vL  
Base frequency 1  
Functions of function keys  
The functions keys allow you to select the position  
or decimal place of each figure (operation  
frequency) you want to increment or decrement  
with the control dial.  
60.0  
Hz  
max=500.0  
min=25.0  
×1000  
×100  
×10  
×1  
F1  
F2  
F3  
F4  
F1  
: Selects the position of hundreds.  
F2  
: Selects the position of tens.  
F3  
: Selects the position of ones.  
F4  
: Selects the first decimal place.  
6-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Operation in Parameter Setup Mode  
If the setting selected is  
changed by selecting a  
menu item  
3 Using the control dial, select/confirm the  
setting you want to change by selecting a  
menu item or specifying a value.  
(In this example, “Panel / LCD-option” is  
selected and confirmed or a frequency of  
90.0Hz is specified and confirmed.)  
When the change you made is saved, the title of  
the parameter stops blinking and the screen  
returns to the previous window.  
Basic Parameters  
CMOd  
Command input mode  
0 :Terminal  
1 :Panel / LCD-option  
2 :RS485-2wire  
3
:RS485-3wire  
If the setting selected is  
changed by specifying a  
value  
Basic Parameters  
vL  
Base frequency 1  
90.0  
Hz  
max=500.0  
min=25.0  
×1000  
×100  
×10  
×1  
6.3 Setting an extended parameter  
1 Select/confirm “Extended parameters” using  
the control dial.  
Parameter Setup Mode  
Extended Parameters  
F100 :Low-speed signal freq  
F101 :Speed reach frequency  
F102 :Speed reach freq band  
F105 :Priority of FWD/REV  
F106 :Input terminal priority  
F9--  
The Extended Parameters window appears.  
Functions of function keys  
F1  
: Displays parameters in the number range of  
900.  
F2--  
The number displayed decrements each time  
this key is pressed.  
F1  
F2  
F3  
F4  
F2  
F3  
F4  
: Displays the previous window.  
: Displays the next window.  
: Displays parameters in the number range of  
200.  
The number displayed increments each time  
this key is pressed.  
2 Change the parameter setting.  
To do this, perform steps 2 and 3 in the “6.2 Setting a basic parameter” section.  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Operation in Parameter Setup Mode  
6.4 Searching for parameters whose settings were  
changed (Search for changed settings)  
The remote keypad is capable of displaying parameters whose current settings are  
different from their default settings, and their current settings.  
1 Select/confirm “Changed Parameters” using  
Parameter Setup Mode  
Changed Parameters  
the control dial.  
The Changed Parameters window appears.  
U - - -]  
Waiting for search  
Functions of function keys  
F1  
: Brings you to the Top View Mode.  
F3  
: Displays, in reverse order, parameters whose  
Top  
Back  
Next  
setting were changed.  
F4  
: Displays, in normal order, parameters whose  
setting were changed.  
F1  
F3  
F4  
2 Search for the desired parameter by pressing  
the [F3] or [F4] key repeatedly.  
Parameter Setup Mode  
Changed Parameters  
The title, function and current setting of the  
parameter selected are displayed.  
CMOd]  
Command input mode  
Functions of function keys  
1 :Panel / LCD-option  
F1  
: Brings you to the Top View Mode.  
Top  
Back  
Next  
F3  
: Displays, in reverse order, parameters whose  
setting were changed.  
F1  
F3  
F4  
F4  
: Displays, in normal order, parameters whose  
setting were changed.  
In this window, settings can be changed.  
Pressing the control dial displays the Parameter Setting window, in which you can  
change settings as required.  
For the operation procedure, see the previous sections.  
6-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Operation in Status Monitor Mode  
In this mode, you can monitor various kinds of statuses and information, such as the  
operating status of the inverter, information on the terminal board, and trip information.  
Status Monitor Mode  
Real-time information  
Rotative direction  
Frequency reference  
Output current  
FWD  
60.0Hz  
22%  
Functions of function keys  
F1  
: Brings you to the Top View Mode.  
F2  
: Displays the previous window.  
Input voltage  
99%  
F3  
: Displays the next window.  
Output voltage  
50%  
F4  
: Brings you to the Parameter Setup Mode.  
Top  
Prm  
F1  
F2  
F3  
F4  
Here are the items that can be monitored in this mode and an explanation of them.  
These items are the same as those that can be monitored with the inverter’s main  
operation panel.  
Display  
of details  
Items displayed  
Description  
Rotating direction  
-
Rotative direction  
Frequency reference *1  
Output current *1  
Input voltage *1  
Output voltage *1  
Torque *1, *2  
PBr overload *1, *2  
Inverter overload *1, *2  
Motor overload *1, *2  
Input terminal 1 :  
S4,S3…R,F  
Set value and current value of parameter F711  
Set value and current value of parameter F712  
Set value and current value of parameter F713  
Set value and current value of parameter F714  
Set value and current value of parameter F715  
Set value and current value of parameter F716  
Set value and current value of parameter F717  
Set value and current value of parameter F718  
v
v
v
v
v
v
v
v
v
Input terminal board information (Standard  
terminal board)  
Input terminal board information (Optional  
terminal board)  
v
v
v
Input terminal 2 :  
L8,L7…L1  
Output terminal board information (Standard  
terminal board)  
Output terminal 1 :  
FL…OUT2  
Output terminal board information (Optional  
terminal board)  
Output terminal 2 :  
R4…OT3  
CPU version information (Application)  
CPU version information (Motor)  
Trip history information 1 (latest)  
Trip history information 2  
-
-
Version of APP-CPU  
Version of MOT-CPU  
Past trip # 1 (latest)  
Past trip # 2  
v
v
v
v
v
-
Trip history information 3  
Past trip # 3  
Trip history information 4  
Past trip # 4  
Parts replacement alarm information  
Cumulative run time  
Parts replacement alarm  
Cumulative run time  
*1: The display item shows the case of a default setting.  
*2: These items are not displayed when the LCD panel is used with a VF-PS1 inverter.  
7-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Operation in Status Monitor Mode  
7. 1 Displaying details of an item monitored  
1 Select/confirm the desired item using the  
control dial.  
Status Monitor Mode  
Output current  
(Ex. Select/confirm “Output current”)  
The monitor window of the item selected appears.  
* Depending on the item selected, no monitor  
window may be displayed.  
22%  
min=0  
Top  
max=185  
Prm  
Functions of function keys  
F1  
F1  
F4  
: Brings you to the Top View Mode.  
F4  
: Brings you to the Parameter Setup Mode.  
How to use monitor windows  
Monitor windows can be broadly classified under the  
following three types.  
<Type of window 1: Displays a value and a  
graph>  
Status Monitor Mode  
Output current  
This type of window displays an analog value,  
such as an output frequency, output current or  
output voltage. (Ex. “Output current”)  
It displays the current value both numerically and  
in a graph form.  
In addition, the minimum allowable value (min)  
and the maximum allowable value (max) are also  
displayed at the bottom of the window.  
22%  
min=0  
Top  
max=185  
Prm  
<Type of window 2: Displays information in a  
graph form>  
Status Monitor Mode  
Input terminal 1 : S4,S3…R,F  
This type of window displays input/output terminal  
information and a life alarm in a graph form. (Ex.  
“Input terminal : S4, S3...R, F”)  
S4 S3 S2 S1 RES ST  
R
F
ON  
OFF  
It displays the ON/OFF status of each terminal  
signal and the ON/OFF status of an alarm signal in  
a graph form.  
Forward run  
Top  
Prm  
If the arrow  
is moved to a terminal or alarm  
* This illustration shows the  
symbol, the name of the function assigned to the  
terminal or the name of the alarm is displayed.  
information displayed when the  
LCD panel is connected to an  
VF-AS1 inverter.  
<Type of window 3: Displays information in a list  
form>  
Past trip # 1 (latest)  
E
:Emergency stop  
This type of window displays detailed trip  
information. (Ex. Past trip # 1 (latest))  
It displays the conditions under which the inverter  
was operated at the occurrence of tripping.  
Sequence number  
1
25.0Hz  
FWD  
Output frequency  
Rotative direction  
Frequency reference  
Output current  
30.0Hz  
40%  
Top  
Prm  
7-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Operation in a copy function  
The copy function can be used when "Copy" is displayed on the upper part of the F3 key.  
The copy function works by the latest combination of LCD Remote Keypad (RKP004Z rev.2 or  
later) with the Inverter version of APP-CPU is V136 or more of VFAS1, V614 or more of  
VFPS1. When either is old, this function does not work.  
Version of APP-CPU  
VFAS1  
V134  
VFPS1  
Limitation in copy function use  
V136  
V612  
V614  
or less  
Disabled  
Disabled  
or more  
Disabled  
Enabled  
or less  
or more  
Disabled  
Enabled  
LCD type form  
RKP004Z-1or0  
Disabled  
Disabled  
After RKP004Z-2  
Moreover, it is not possible to copy normally in the following cases even if the copy  
function can be used.  
1) It is not possible to copy, when the inverter form differs,.  
2) It is not possible to copy to the inverter while driving.  
3) It is not possible to copy, when a minimum unit of the frequency is different.  
4) It is necessary to reset up the parameters after the copy when copying between the  
inverters from which capacity differs.  
5) It is necessary to reset power supply after the copy when the unit of time differs.  
Explanation of the top window  
• Display of commands executed:  
Display of  
Display of  
commands  
operating status  
“FWD” or “REV” is displayed to indicate the direction of  
rotation.  
The operation frequency is displayed in the form of  
††. Hz.”  
Top View Mode  
FWD 60.0 Hz  
RUN  
• Display of operating status:  
“RUN” is displayed during operation.  
“STOP” is displayed during a stop.  
“Trip” is displayed in the event of tripping.  
• Display of output frequency:  
60.0  
Hz  
Overheat alarm  
Lng  
Quick  
Copy  
---  
F1  
F2  
F3  
The operation frequency is displayed in the form of  
††. Hz.”  
• Display of alarm/tripping:  
Display of output frequency  
Display of alarm/tripping  
If an error or tripping occurs, an error or trip code is displayed.  
• Display of error/tripping message:  
Display of error/tripping message  
If an error or tripping occurs, an error or trip message is displayed  
Functions of function keys  
F1Switches between Quick mode and Standard Setting mode  
F2  
Brings you to the Language selection window.  
F3Brings you to Copy mode window.  
8-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Operation by a copy function  
8. 1 Copy to LCD  
Push the F3 key on an initial screen and the copy mode screen is displayed. It is not  
possible to drive with the [RUN] key in the following 35 screen display.  
1 Select the memory saving group using the  
Copy Mode  
Group selection  
control dial.  
Memory - A  
Memory- B  
Top  
Info  
2
Select copy direction [Copy to the LCD  
memory] using the control dial.  
Copy Mode  
Memory- A  
Copy direction  
Copy to the inverter]  
Copy to the LCD memory]  
Top  
3 Display of copy waiting  
Copy Mode  
Memory- A  
Copy starts when the [F4] key is input.  
Copy to the LCD memory]  
Waiting  
Please push F4 key  
when starting  
LCD メモリへコピー]  
Top  
Start  
F4  
4 Display of copy loadingfixed screen)  
Copy finishes in 1 minute. When the copy  
is not completed even if it waits 2 minutes  
or more, please reset a power supply and  
copy again.  
Copy Mode  
Memory- A  
Copy to the LCD memory]  
Loading  
Now loading.  
Please wait for about 1 min.  
LCD メモリへコピー]  
Note) The status display( )doesn't rotate when  
copying it while driving until the copy is completed.  
Copy Mode  
Memory- A  
5 Display of copy finish  
Return to the copy direction window  
as above “2” when press the ESC key  
after copy.  
Copy to the LCD memory]  
Finish  
Copy was completed normally.  
Please push ESC-key.  
CRC code6AE3  
Top  
8-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Operation by a copy function  
8. 2 Copy to inverter  
There is no data in LCD, and copy it to LCD at the time of purchase.  
(Chap.: 8.1)  
Push the F3 key on an initial screen and the copy mode screen is displayed. It is not  
possible to drive with the [RUN] key in the following 35 screen display.  
1 Select the memory saving group using the  
Copy Mode  
Group selection  
control dial.  
Memory - A  
Memory- B  
Top  
Info  
2 Select copy direction [Copy to the inverter  
memory] using the control dial.  
It is not possible to copy to the inverter  
when there is no information in the selected  
memory. Copy to the LCD first  
Copy Mode  
Memory- A  
Group selection  
Copy to the inverter]  
Copy to the LCD memory]  
(ref.: Chapter 8.1).  
Top  
3 Display of copy waiting  
Copy Mode  
Memory- A  
Copy starts when the [F4] key is input  
Copy to the inverter]  
Waiting  
Please push F4 key  
when starting  
LCD メモリへコピー]  
Top  
Start  
F4  
4 Display of copy loadingfixed screen)  
Copy finishes in 1 minute. . When the copy  
is not completed even if it waits 2 minutes  
or more, please reset a power supply and  
copy again.  
Copy Mode  
Memory- A  
Copy to the inverter]  
5 Display of copy finish  
Copy Mode  
Memory- A  
Return to the copy direction window  
Copy to the inverter]  
Finish  
as above “2” when press the ESC key  
after copy.  
Copy was completed normally.  
Please push ESC-key.  
CRC code6AE3  
.
Top  
8-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Operation by a copy function  
8. 3 Confirm a memory information  
There is no data in LCD, and copy it to LCD at the time of purchase.  
(Chap.: 8.1)  
Push the F3 key on an initial screen and the copy mode screen is displayed.  
1 Select the memory saving group that you  
Copy Mode  
Group selection  
want to confirm using the control dial.  
Memory - A  
Memory- B  
Top  
Info  
2 Push the [F4] key.  
Copy Mode  
Group selection  
Memory - A  
Memory- B  
Top  
Info  
F4  
3
Displays detail information in the LCD  
memory.  
Copy Mode  
Memory- A  
Inverter information  
TypeDisplays VFAS1 or VFPS1.  
RatingDisplays voltage and capacity.  
Type : VFAS1  
Rating : 200V-3.7kW  
Version of APP-CPU : v136  
CRC code : 6AE3  
Top  
Version of APP-CPU:  
Start  
Displays CPU version for the application.  
The total parameter might differ when CPU version is different.  
CRC code:  
The CRC code is calculated from the communication data. It is detected whether it  
normally copies to the inverter by agreeing with the CRC in the memory code and  
the CRC in the copy completion display when copying it to the inverter.  
8-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. List of function key functions  
The abbreviations and graphic symbols displayed at the bottom of the window refer to  
the functions of function keys, and the pressing a function key performs the  
corresponding function. The abbreviations and graphical symbols in the window  
correspond to the [F1] to [F4] keys, respectively starting from the left.  
Top View Mode  
FWD 60.0 Hz  
STOP  
0.0  
Hz  
Lng  
Quick  
---  
Press the [F1] key to perform this function.  
Press the [F2] key to perform this function.  
Press the [F3] key to perform this function.  
Press the [F4] key to perform this function.  
Here are the functions keys available and their functions.  
Display  
Function  
Function  
Reference  
Display  
position  
Item  
key  
displayed  
Switches between Quick mode and Standard Setting  
mode.  
Quick  
5-2  
Panel  
Switches between Operation Panel and Remote.  
Switches between Local and Remote.  
Measurements for Peak/Minimum Hold starts.  
Brings you to the Top View Mode.  
Displays parameters in the number range of 900 ~  
displays parameters in the number range of 100.  
Selects the position of hundreds.  
Brings you to the Language selection window.  
Displays the previous window.  
5-2  
5-2  
5-2  
4-1  
Loc/Rem  
Update  
Top  
[F1] key  
Far left  
F9-- ~ F1--  
6-3  
×1000  
Lng  
5-1  
5-4  
6-1  
5-1  
6-1  
5-1  
[F2] key  
[F3] key  
Left center  
×100  
Selects the position of tens.  
Displays the next window.  
×10  
Selects the position of ones.  
Right  
Displays, in reverse order, parameters whose setting  
were changed.  
center  
Back  
6-4  
Copy  
---  
Brings you to the copy mode.  
8-1  
-
No function.  
Mon  
Prm  
Brings you to the Top View Mode.  
Brings you to the Parameter Setup Mode.  
Displays parameters in the number range of 100 ~  
displays parameters in the number range of 900.  
Selects the first decimal place.  
4-1  
4-1  
F1-- ~ F9--  
×1  
6-3  
5-1  
6-4  
[F4] key  
Far right  
Displays, in normal order, parameters whose setting  
were changed.  
Next  
JOG  
Info  
Executes a jog run command.  
5-5  
8-3  
Brings you to the memory information.  
9-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Specifications  
Item  
Specifications  
Model number  
Applicable model   
Communication  
setting  
RKP004Z  
VF-AS1/PS1 inverter unit  
Baud rate: 19200 bps (F800=1)  
Communication type: 2-wire RS485  
Parity: even (F801=1)  
Use environments  
Indoors, an altitude of 3000m or less, where the product will  
not be exposed to direct sunlight, corrosive or explosive  
gases, vapor, coarse particulates including dust, and where  
there is no grinding fluid or grinding oil nearby  
Ambient temperature-10 to +60°C  
Storage temperature-25 to +65°C  
Relative humidity  
Vibration  
20 to 93% (no condensation and absence of vapor)  
5.9m/s2 (0.6G) or less (10 to 55Hz) (compliant with JIS C  
60068-2-6)  
Cooling method  
Self-cooling  
Outside dimensions (unit: mm)  
98  
26  
10-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. Before making a service call  
If a problem occurs, follow the instructions in this table to track down and eliminate the  
cause of the problem.  
Problems  
Possible causes  
Remedies  
Nothing is displayed on the • The inverter connected is not  
• Check whether the inverter is turned  
on.  
screen.  
turned on or it is not connected  
securely.  
• Check the interconnect cable and the  
connector for loosening.  
The Startup window  
• A cable other than a dedicated • Use a dedicated cable.  
appears, but the message  
“CONNECTION IN  
PROGRESS” does not out  
and the screen does not turn inverter is different from that of  
to the next window. the unit.  
one is used.  
• The communication speed  
setting or parity setting of the  
• Set the communication speed and the  
parity, as specified below.  
F800 (communication speed) = 1  
(19,200 bps)  
F801 (parity) = 1 (even parity)  
Then turn the unit off and then back on  
to reset it.  
Although line information is • Connection may be broken  
• Move to another window by pressing  
the [ESC] key to reload textual  
information, and check the cable and  
the connector for loosening.  
• This phenomenon does not mean that  
the unit is faulty.  
displayed on the screen,  
textual information is not  
displayed. Or some  
characters are not displayed  
correctly.  
during communication.  
• If the unit uses an old language  
database, the codes shown  
below may be displayed.  
<Ex.>  
“F123” “:004” “M301”  
The error code E-17 (key  
failure alarm) is displayed.  
• The same key is pushes more • Check whether the key operates  
than 20 seconds.  
normally. If it does not operate  
normally, it has to be repaired.  
• Change the setting of the basic  
parameter COMd (command input  
mode) to 1 (Panel / LCD-option).  
Operation cannot be  
controlled with the [RUN]  
key or the [STOP/RESET]  
key.  
• Panel Operation mode is not  
enabled.  
• The operation frequency is set • Set an operation frequency according  
at 0.0Hz.  
to the setting of the basic parameter  
FMOd (frequency input mode 1).  
When performing operation at the  
frequency set with the extension  
operation panel (see section 5.1), set  
FMOd to 4 (Panel / LCD-option).  
Operation can be controlled • The basic parameter Fr (panel • Change the setting of the parameter Fr  
with the [RUN] key and the  
[STOP/RESET], but the  
direction of rotation cannot  
be changed with the  
FWD/REV selection) is set to 0  
or 1.  
(panel FWD/REV selection) to 2 or 3.  
[FWD/REV] key.  
The inverter has tripped  
because of a communication turned ON (enabled).  
error (Err5).  
• F803 (com time-out time) is  
• Connection may be broken during  
communication. Check the cable and  
the connector for loosening.  
* By default, the function of  
measuring the time for a  
time-out is turned off (disabled).  
Although the [STOP/RESET] • Multiple commands have been • Check to see if multiple commands  
key was not pressed, the  
machine stopped operating.  
entered because the three keys have been entered as a result of  
[F2], [F3] and [F4] or [ESC], pressing the three keys in rapid  
[FWD] and [RUN] were pressed succession.  
in rapid succession.  
• Check whether the key operates  
• The [STOP/RESET] key may be normally. If it does not operate  
broken and held in the ON  
position.  
normally, it has to be repaired.  
11-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. Before making a service call  
Remedies  
Problems  
Using a copy function is not • APP-CPU and the LCD type  
possible. form may not be appropriate.  
Possible causes  
• When APP-CPU and the LCD type form  
are not appropriate the copy function  
cannot be used.  
Memory data error message • Something is wrong with the  
• Copy to the LCD again. (ref. Chapter 8)  
is displayed.  
internal memory.  
Disconnection error  
• Connection may be broken  
during communication.  
• Check the cable and the connector,  
then copy again.  
message is displayed when  
the copy function is used.  
"TOSHIBA" screen is  
momentarily displayed when  
using copy function or the  
confirmation of the memory  
information.  
• This phenomenon appears only • Does not appear after doing copy to the  
once when using copy function  
for the first time.  
LCD one time(ref. Chapter 8.1).  
“----“ is displayed when using • It occurs when LCD has no  
the confirmation of the memor information or communication  
• Copy to the LCD. (ref. Chapter 8)  
information function.  
signal between LCD and the  
inverter is disconnected while  
copying to the LCD.  
German cannot be selected. • APP-CPU version of VFAS1 is • German can be selected by using  
less than V104.  
APP-CPU version of VFAS1 is V106 or  
greater.  
11-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. Warranty  
Any part of the unit that proves defective will be repaired and adjusted free of charge  
under the following conditions:  
1. If the product breaks down within one year after delivery, although it is installed and  
handled properly, and if the breakdown is undoubtedly attributable to a defect in  
designing or manufacturing by Toshiba, the product shall be repaired free of charge.  
2. This warranty applies only to the delivered unit.  
3. For the following kinds of failure or damage, the repair cost shall be borne by the  
customer even within the warranty period.  
(1) Failure or damage caused by misuse, or unauthorized repairs or modification  
(2) Failure or damage caused by the drop of the product after purchase or rough  
handling during transportation  
(3) Failure or damage caused by fire, salty water or wind, corrosive gas, earthquake,  
storm or flood, lightning, abnormal voltage supply, or other natural disasters  
(4) Damage caused by using the product for a purpose unauthorized for it as an  
external operation panel  
4. If there are any warranty conditions otherwise provided for, those conditions will  
govern.  
12-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Texas Instruments Stereo Amplifier TPA0243 User Manual
Thermo Products Furnace OH6FA072D48B User Manual
TOA Electronics Stereo Amplifier IP 600D User Manual
Toshiba Computer Drive MK4026GAX HDD2193 User Manual
Toshiba Projection Television 32WL55A User Manual
Tripp Lite Switch B160 002 R User Manual
Tripp Lite TV Cables U233 008 User Manual
Vermont Casting Indoor Fireplace WMC36 User Manual
Vizio Flat Panel Television XMA500 User Manual
VocoPro Microphone DA2277 User Manual