Download from Www.Somanuals.com. All Manuals Search And Download.
Do not place a spray can near the air outlet grille less than 1 m.
The warm air from indoor and outdoor units may cause an explosion of the spray can.
WARNING
Installation must be requested from the supplying retail dealership or professional
installation vendors. Installation requires special knowledge and skill. If customers
install on their own, it can be a cause of fire, electric shock, injury or water leakage.
Do not use any refrigerant different from the one specified for complement or
replacement. Otherwise, abnormally high pressure may be generated in the
refrigeration cycle, which may result in a failure or explosion of the product or an
injury to your body.
Do not disassemble, modify or relocate the unit by yourself. It may become the cause
of fire, electric shock, or water leakage. For repair or relocation, please request
service from the supplying retail dealership.
EN
When relocating or repairing the unit, please contact the supplying retail dealership.
When there is a kink in the wiring, it may be the cause of electric shock or fire.
Do not select a location for installation where flammable gas may leak. If there is any
gas leakage or accumulation around the unit, it can be a cause of fire.
Do not select a location for installation where there may be excessive water or
humidity, such as a bathroom. Deterioration of insulation may be a cause of electric
shock or fire.
Earth work should be requested from the supplying retail dealership or professional
vendors. Insufficient grounding work may be the cause of electric shock. Do not
connect the earth wire to a gas pipe, water pipe, lightning conductor, or telephone
earth wire.
You must use an independent power outlet for the power supply. If a power outlet
other than the independent outlet is used, it may cause a fire.
Check that the circuit breaker is installed correctly. If the circuit breaker is not properly
installed, it may cause an electric shock. To check the installation method, please
contact the supplying retail dealership or the professional vendor who installed the
unit.
During an error (such as a burning odor, not cooling, or not warming), stop operating
the unit and turn off the circuit breaker. Continuous operation may be a cause of fire,
or electric shock. Please request repair or service from the supplying retail
dealership.
Do not turn ON/OFF the circuit breaker or operate buttons with a wet hand. It may be
a cause of electric shock.
Do not insert any material (metal, paper, or water, etc.) into the air outlet or air intake
opening. Fan may be rotating at high speed inside or there are high voltage sections,
which may cause an injury or electric shock.
Do not clean the air filter (Locally Procured) by yourself, it may become the cause of
an electric shock or an injury. Request the service of the supplying retail dealership.
When the air-conditioning unit does not cool or warm, there may be a leakage of
refrigerant. Please consult the supplying retail dealership.
The refrigerant used in the air-conditioning unit is safe. It will not leak under normal
operating conditions, but if it leaks into the room and contacts a heat source such as
a heater, or stove, it may cause a harmful reaction.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
When water or other foreign substances enter the internal parts, stop operating the
unit immediately and turn off the circuit breaker. Operating the unit continuously may
cause fire or electric shock. Please contact the supplying retail dealership for repair.
Do not clean the inside of the air-conditioning unit yourself. Please request internal
cleaning of the air-conditioning unit from the supplying retail dealership. Incorrect
cleaning may cause breakage of resin parts or insulation defects of electrical parts,
causing water leakage, electric shock or fire.
Do not damage or modify the power cable. Do not connect the cable midway, or use
a multiple outlet extension cord that is shared by other devices. Failure to do so may
cause fire.
Do not place heavy objects on the power cable, expose it to heat, or pull it. To do so
may cause electrical shock or fire.
Do not expose your body directly to cool air for a long time.
Do not insert your finger or any article into the air inlet/outlet.
CAUTION
Do not touch the body of the unit. It may cause an electric shock or an injury.
Ensure that drained water is discharged. When the discharging water process is not
sufficient, water may leak, causing water damage to furniture.
To check that the installation method used is correct, please contact the supplying
retail dealership or the professional vendor who installed the unit.
If the indoor unit piping outlet is exposed due to relocation, close the opening.
Touching internal electrical parts may cause injury or electric shock.
Do not wash the main air-conditioning unit with water. It may cause an electric shock.
Do not place any containers such as a vase containing fluid on the unit. It might
cause water to enter the unit and deteriorate the electrical insulation, causing an
electric shock.
When using the unit in a closed room, or operating with other combustion appliances,
make sure to open a window occasionally for ventilation. Insufficient ventilation may
cause suffocation due to a lack of oxygen.
Do not use combustion appliances in the direct flow of the air from the air-
conditioning unit. Poor combustion of a combustion appliance may cause suffocation.
Avoid operating for long periods in a high humidity environment (over 80%) such as
with the windows or doors open. There may be condensation on the indoor unit and
droplets may fall onto the furniture.
When the unit won’t be used for a long time, turn off the main switch or the circuit
breaker.
At least once a year check if the mounting table of the outdoor unit is damaged or not.
If a damaged state is ignored, the unit may fall or over-turn, causing an injury.
Do not stand on the outdoor unit or place anything on the unit. It may be the cause of
injury due to falling or over-turning.
Any damage to the unit may cause an electric shock or fire.
Download from Www.Somanuals.com.3All Manuals Search And Download.
Do not place anything around the outdoor unit or allow fallen leaves to accumulate
around it. If there are fallen leaves, small animals could enter and contact internal
electrical parts, causing a failure or fire.
Do not place animals and plants in places where wind from the air-conditioning unit
flows directly. It may have a negative influence on the animal or plant.
Do not use for special applications such as storage of food or animals, or to display
plants, precision devices, or art objects.
Do not use on ships or in other vehicles. It may cause a failure in the air-conditioning
unit. In addition, it may damage these items.
Do not place other electrical appliances or furniture under the unit. Water droplets
might fall, causing damage or failure.
When performing maintenance, you must stop operating the unit and turn off the
circuit breaker. Since the fan inside may be rotating at high speed, it may cause an
injury.
EN
When you hear thunder and there might be a lightning strike, stop operating the unit
and disconnect the circuit breaker. If lightning strikes, it may cause a failure.
• Batteries for remote control unit:
- Should be inserted with correct polarity (+) and (-).
- Should not be recharged.
- Do not use batteries for which the “Recommended usage period” has expired.
- Do not keep used batteries inside the remote control unit.
- Do not mix different types of batteries, or mix new batteries with old ones.
- Do not directly solder the batteries.
- Do not short-circuit, disassemble, heat, or throw batteries into a fire. If batteries are not
disposed of correctly, they may burst or be the cause of fluid leakage, resulting in burns or
injuries. If touching the fluid, wash thoroughly with water. If it touches devices, wipe off to
avoid direct contact.
- Do not place within reach of small children. If a battery is swallowed, consult a doctor
immediately.
• When you press CLOCK •, CHECK •, FILTER • and RESET • button, do not let any foreign
substances enter and remain inside of the remote control.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
1
6
7
SIGNAL RECEIVING UNIT DISPLAY
COOLING / HEATING OPERATION
1 OPERATION (Green)
2 TIMER (Orange)
3 PRE.DEF (Preheat/Defrost/Self Cleaning) (Orange)
4 TEMPORARY button
1. Press
: Select Cool
, or Heat
.
2.
Press
: Set the desired temperature.
: Select AUTO, LOW , LOW+
3. Press
HIGH
, MED
, MED+
, or
.
DRY OPERATION
For dehumidification, a moderate cooling performance is controlled automatically.
1. Press : Select Dry
.
2.
Press
: Set the desired temperature.
2
PREPARATION BEFORE USE
Loading Batteries
8
Hi-POWER OPERATION
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) following the (+) and
(–) positions.
To automatically control room temperature and cooling (or heating) capacity for faster
cooling (or heating) operation. (except in DRY mode)
Clock Setup
Press
: Start and stop the operation.
1. Push
by tip of the pencil.
If timer indication is flashing, go to the next step 2.
9
ECO OPERATION
To automatically control room to save energy (except in DRY mode)
2. Press
or
: Adjust
Press : Start and stop the operation.
the time.
3. Press
Remote Control Reset
Note: Cooling operation; the set temperature will increase automatically 1 degree/hour for
2 hours (maximum 2 degrees increase).
: Set the time.
For heating operation the set temperature will decrease.
Push
by tip of the pencil or
10
1. Remove the batteries.
TEMPORARY OPERATION
2. Press
.
In case of the misplaced or discharged remote
control
3. Insert the batteries.
•
Pressing the TEMPORARY button, the
unit can start or stop without using the
remote control.
Operation mode is set on AUTOMATIC
operation, preset temperature is 24°C
and fan operation is automatic speed.
Start/Stop
1. Press
operation.
(A receiving beep is heard)
2. Press to stop
operation.
to start
•
TEMPORARY button
(A receiving beep is heard)
3
REMOTE CONTROL
1 Infrared signal emitter
11
TIMER OPERATION
2 Start/Stop button
Set the timer when the air conditioner is operating.
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 On timer button (ON)
Setting the ON Timer
Setting the OFF Timer
1
Press
: Set the desired ON timer. Press
: Set the desired OFF timer.
7 Off timer button (OFF)
8 Setup button (SET)
9 Clear button (CLR)
2
3
Press
Press
: Set the timer.
Press
Press
: Set the timer.
0 Memory and Preset button (PRESET)
! One-Touch button (ONE-TOUCH)
@ High power button (Hi-POWER)
# Economy button (ECO)
$ Quiet button (QUIET)
: Cancel the timer.
: Cancel the timer.
Daily timer allows the user to set both the ON & OFF timers and will be activated on a
daily basis.
% Comfort sleep button (COMFORT SLEEP)
^ Set clock button (CLOCK)
& Check button (CHECK)
* Reset button (RESET)
Setting Everyday Timer
1
2
3
4
Press
Press
: Set the ON timer.
: Set the OFF timer.
Press
Press
.
Note:
When pushing the “SWING”, “FIX” and
“FILTER” buttons, indoor unit does not
operate and the receiving beep sound also not appear.
button during the
(
or ) mark flashing.
•
During the every day timer is activating, both arrows ( , ) are indicated.
Note:
4
ONE-TOUCH
•
•
Keep the remote control in accessible transmission to the signal receiving unit;
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.
Press the “ONE-TOUCH” button for fully automated operation that is customized to the
typical consumer preferences in your region of the world.
The customized settings control temperature, air flow strength and other settings to provide
you alternate contact with “ONE-TOUCH” of the button. If you prefer other settings you can
select from the many other operating functions of your Toshiba unit.
12
PRESET OPERATION
Press
: Start the operation.
Set your preferred operation for future use. The setting will be memorized by the unit for
future operation.
1. Select your preferred operation.
5
AUTOMATIC OPERATION
2.
P
Press and hold
displays.
for 3 seconds to memorize the setting. The
mark
To automatically select cooling or heating operation
1. Press
2.
: Select A.
3. Press
: Operate the preset operation.
Press
: Set the desired temperature.
: Select AUTO, LOW , LOW+
3. Press
HIGH
, MED
, MED+
, or
.
Download from Www.Somanuals.com.5All Manuals Search And Download.
13
19
REMOTE CONTROL A-B SELECTION
AUTO RESTART OPERATION
To automatically restart the air conditioner after the power failure (Power of the unit must be
on.)
To separate using of remote control for each indoor unit in case of 2 air conditioners are
installed nearly.
Setting
Remote Control B Setup.
1. Press and hold the TEMPORARY button on the signal receiving unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5
seconds)
1. Press TEMPORARY button on the signal receiving unit to turn the air conditioner ON.
2. Point the remote control at the signal receiving unit.
3. Push and hold
button on the Remote Control by the tip of the pencil. “00” will be
2.
Press and hold the TEMPORARY button on the signal receiving unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not blink)
shown on the display.
4. Press
during pushing . “B” will show on the display and “00” will
disappear and the air conditioner will turn OFF. The Remote Control B is memorized.
14
QUIET OPERATION
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
To operate at super low fan speed for quiet operation (except in DRY mode)
3. Default setting of Remote Control from factory is A.
Press : Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate cooling due to
low sound features.
15
COMFORT SLEEP OPERATION
A
B
For comfortable sleep, automatically control air flow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically 1 degree/hour
for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature
will decrease.
EN
SELF CLEANING OPERATION (COOL
AND DRY OPERATION ONLY)
16
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode, the fan will
continue to run for other 30 minutes, then it will turn off automatically. This will reduce
the moisture in the indoor unit.
If the time of “Cool” or “Dry” operation is less than 10 minutes, the self cleaning
operation is not performed.
2.
To stop the unit immediately, press the
more 2 times within 30 seconds.
17
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes
when suddenly restarted or switched to ON.
2.
Preheating operation: Warm up the unit for 5 minutes before blowing warm air.
3. Warm air control: When the room temperature reaches the set temperature, the fan
speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into the room. When the
outdoor temperature is too low, use another recommended heating apparatus in
combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit where it will not
be subjected to snow drifts, accumulation of leaves or other seasonal debris.
Air conditioner operating conditions
Temp.
Outdoor Temperature
Room Temperature
Operation
Heating
Cooling
Dry
Less than 28°C
21°C ~ 32°C
17°C ~ 32°C
Refer to the Installation Manual of the outdoor unit.
18
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
Cooling or Heating is abnormally low.
•
•
The power main switch is turned off.
The circuit breaker is activated to cut off
the power supply.
Stoppage of electric current
ON timer is set.
•
•
The air filter (Locally procured) is blocked
with dust.
The temperature has been set
improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor unit is
blocked.
•
•
•
•
•
•
The fan speed is too low.
The operation mode is DRY.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)
Toshiba Carrier Air Conditioning (China) Co., Ltd.
(Address, city, country)
Building 1, No.60, 21st Avenue, Baiyang Street,
Hangzhou Economic and Technological Development Area, China
(Name of the Importer/Distributor in EU)
(Address, city, country)
TOSHIBA CARRIER UK LTD.
Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB,
United Kingdom
In Turkey
Klimanıza ilişkin daha ayrıntılı bilgiler için ürün tanıtım broşürlerine, gerektiğinde Alarko Carrier Yetkili Satıcı ve Servislerine ulaşabilmek için 444 0 128
numaralı Müşteri Danışma Hattımıza başvurabilirsiniz.
Download from Www.Somanuals.com. All Manuals Search And Download.
|