DT34 and DT54 Series Rotary Sprinklers
Installation & Service Instructions
Note: For preliminary use only.
Introduction ______________________________________________________________________
The DT34 and DT54 series full-circle rotary sprinklers are designed
specifically for golf course applications.
Manufactured from durable, high-strength engineering plastic and
O
T
A U
O F F
O N
stainless-steel components, these sprinklers incorporate many innovative
and time-proven features for lasting, maintenance-free operation.
Prior to installing the sprinkler, read through the recommended installation
and start-up procedures. Please observe all WARNINGS and CAUTIONS
when installing and operating this equipment.
DT34 Electric Valve-In-Head
DT54 Electric Valve-In-Head
Features _______________________________________________________________________________
■ Main nozzle trajectory allows for 25 and 15 degree selections
■ Full 4" (10,1 cm) pop-up clears tall grasses
■ Nozzles color-coded by radius and gallonage
■ Cap serves as an effluent water indicator
■ Variable stators
■ Three body thread types available: NPT, BSP and ACME
■ Manual sprinkler control, On-Off-Auto (electric models only)
■ Bowl-vented discharge (atmospheric) minimizes the
differential pressure required for regulation and ensures
positive valve closure (electric models only)
■ All internal components serviceable from the top of the
sprinkler
■ Selectable pressure regulation settings of 50 psi (3.4 bar),
65 psi (4.5 bar), 80 psi (5.5 bar) or 100 PSI (6.9 bar) to
ensure consistently accurate nozzle performance
regardless of elevation (electric models only)
■ Large selection of color-coded nozzles available
■ Durable plastic and stainless-steel construction
■ Optional radius reduction screw
■ Three body activation types available: Electric VIH,
Normally Open Hydraulic VIH, and Check-O-Matic
Specifications and Performance/Application Data _______________________________________
DT34 Series
DT54 Series
■
■
■
■
■
Radius: 52'–92' (15,9–28,0 m)
Flow Rate: 15–50 GPM (56,7–189,3 LPM)
Trajectory: Selectable 15° or 25°
Arc: Full Circle
■
■
■
■
■
■
■
■
Radius: 52'–100' (15,9 m–30,5 m)
Flow Rate: 15–62 GPM (56,8–234,7 LPM)
Trajectory: Selectable 15° or 25°
Arc: Full Circle
Recommended Operating Pressure: 65–100 PSI
(4,5–6,9 Bar)
Recommended Operating Pressure: 65–100 PSI (4,5–6,9 Bar)
Minimum Pressure: 40 PSI (2,8 Bar)
Maximum Pressure: 150 PSI (10,3 Bar)
Precipitation Rate:
■
■
■
Minimum Pressure: 40 PSI (2,8 Bar)
Maximum Pressure: 150 PSI (10,3 Bar)
Precipitation Rate:
■
Minimum: 0.50"/hr (12,7 mm/hr)
Maximum: 0.72"/hr (18,3 mm/hr)
■
Minimum: 0.46"/hr (11,7 mm/hr)
■
■
Maximum: 0.63"/hr (16 mm/hr)
■
■
■
■
Body Height: 11" (27.9 cm)
Pop-Up Height: 4.1875" (10.6 cm)
Inlet Size: 1.5" NPT, BSP or ACME
Solenoid:
■
■
■
■
Body Height: 10" (25.4 cm)
Pop-Up Height: 4.1875" (10.6 cm)
Inlet Size: 1" NPT, BSP or ACME
Electric Valve-in-head Solenoid:
■
Inrush current: 0.30A @ 24 VAC, 50/60 Hz
Holding current: 0.20A @ 24 VAC, 50/60 Hz
■
Inrush current: 0.30A @ 24 VAC, 50/60 Hz
Holding current: 0.20A @ 24 VAC, 50/60 Hz
■
■
■
■
■
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic model checks up to 37' (11,2 m) of elevation.
Nine Nozzle Variations: See chart on page 2.
■
■
■
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic model checks up to 37' (11,2 m) of elevation.
Seven Nozzle Variations: See chart on page 2.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Procedure ___________________________________________________
To assure maximum performance from your 800S series sprinklers, read these instructions
completely prior to installation or service.
Figure 1
O
T
A U
F
F
O
N
O
Constructing Swing Joints
1. Construct or provide triple swing joints for each sprinkler as shown in Figure 1. Use PVC or
ABS pipe nipple for the sprinkler connection.
Note: On sites where the possibility of heavy equipment rolling over a sprinkler exists, the
swing joint will flex preventing damage to the lateral or main lines. On a new installation in
raw ground where the sprinklers are to be initially installed above the finished grade and
lowered when new turf is established, the swing joint allows sprinkler repositioning without
changing risers. This is a common and practical procedure which eliminates the problem of
dirt being accidentally introduced into the lateral lines when a riser is changed.
2. Flush lines thoroughly prior to installing sprinkler.
3. Apply PTFE tape on riser threads (not required on ACME threads). Install sprinkler to riser and tighten.
CAUTION: Use only PTFE tape on riser threads. Use of pipe dope or other types of sealing compounds can cause
deterioration of sprinkler body threads.
Connecting Control Wires (Electric Models Only)
1. Route control wires to sprinklers. Provide extra wire at sprinkler to allow for height adjustment. One common wire and station
wire is required for each sprinkler. See Wire Sizing Chart, Table 1 for proper application.
Note: Wire length data provided in Table 1 is the sum of the station and common wire legs. See example in Figure 2.
Table 1: Wire Sizing Chart
Total Wire Length Between Controller and Sprinkler
1 Sprinkler 2 Sprinklers 3 Sprinklers 4 Sprinklers
Voltage AWG
mm2
Voltage Drop Circular Mils
23
23
23
23
23
23
23
24
24
24
24
24
24
24
2.5/2.5
2.5/4.0
14/10 2.5/5.5
4
4
4
4
4
4
4
5
5
5
5
5
5
5
4100
5315
7250
6530
8465
11515
10400
4100
5315
7250
6530
8465
11515
10400
3285' 1001 m 1642' 500 m 1095' 334 m 821'
4259' 1298 m 2129' 649 m 1419' 432 m 1064'
5809' 1770 m 2904' 885 m 1936' 590 m 1452'
5232' 1595 m 2616' 797 m 1744' 531 m 1308'
6783' 2067 m 3391' 1033 m 2261' 689 m 1695'
14/14
14/12
250 m
324 m
443 m
399 m
517 m
703 m
12/12
12/10
12/8
4.0/4.0
4.0/5.5
4.0/7.0
9227'
2812 m
4613'
1406 m 3075'
937 m
2306'
10/10 5.5/5.5
14/14
8333' 2540 m 4166' 1270 m 2778' 846 m
2083' 635 m
313 m
4106' 1251 m 2053' 626 m 1369' 417 m 1026'
2.5/2.5
14/12 2.5/4.0
14/10
1622 m
1331' 406 m
5323'
2662' 811 m 1774' 541 m
2213 m
6540' 1993 m 3270'
2420'
553 m
498 m
646 m
7261'
3631' 1106 m
996 m
8478' 2584 m 4239' 1292 m 2826' 861 m
738 m 1815'
2180' 664 m 1635'
2119'
2.5/5.5
12/12 4.0/4.0
12/10 4.0/5.5
11533'
10416'
12/8
10/10 10/10
3515 m 5766' 1757 m 3844' 1172 m 2883' 879 m
5208' 3472' 2604'
4.0/5.5
3175 m
1587 m
1058 m
790 m
Figure 2
2. Attach control wires to solenoid leads using an
approved waterproof splicing method.
CAUTION: All wire splices and field
connections must be waterproofed to prevent
short circuit to ground and subsequent controller
damage.
Station Wire = 1095' (334m)
Common Wire = 1095' (334m)
Total Wire Length = 2190' (668m)
Connecting Hydraulic Control Tubing
1. Route control tubing from the controller to the
sprinkler location(s).
Note: Leave an 18" (45.7 cm) service loop of tubing
at each sprinkler to facilitate movement of sprinkler
and service operations. Refer to Table 2 for tubing
run length and sprinkler elevation information.
Table 2: Hydraulic Control Systems
Maximum Distance
Type of System*
From Controller
Elevation Restrictions
Normally Open (01)
with 3/16" Control Tubing
Valve elevation should not exceed
25' ABOVE controller elevation or
70' BELOW controller elevation.
2. Flush tubing thoroughly to remove all air and debris.
500'
3. Remove the tube retainer and poly cap from the
tubing adapter at the base of the sprinkler.
Normally Open (01)
with 1/4" Control Tubing
Valve elevation should not exceed
25' ABOVE controller elevation or
70' BELOW controller elevation
1000'
4. Slide the tube retainer over the end of the control
tubing and attach tubing to adapter.
- All hydraulic connections on Toro valves are 1⁄4" insert type.
- Control line pressure must be equal to or greater than mainline pressure.
- Control line pressure range is 40 to 150 PSI.
*
5. Slide tube retainer over adapter area to secure tubing.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
System Start Up _________________________________________________________
The following is a recommended procedure that will protect system components during system start-up. The procedure is based on a
velocity fill rate of less than 2' (.61 m) per second. See Table 3 below.
Table 3: Recommended System Fill Rate
Pipe Size
Flow
Velocity
Pipe Size
Flow
Velocity
in.
1/2
3/4
cm
1.3
1.9
2.5
3.1
3.8
5.0
6.4
GPM
2
3
LPM
7.6
ft/sec
m/sec
0.49
0.59
0.46
0.57
0.43
0.55
0.56
in.
3
4
6
8
cm
7.6
GPM
45
75
150
250
450
500
LPM
170.3
283.9
567.8
946.3
1703.0
1893.0
ft/sec
m/sec
0.57
0.57
0.53
0.52
0.60
0.47
1.60
1.92
1.50
1.86
1.41
1.80
1.84
1.86
1.87
1.73
1.70
1.97
1.55
11.4
18.9
37.9
37.9
75.7
113.6
10.1
15.2
20.2
25.4
30.5
1
5
1-1/4
1-1/2
2
10
10
20
30
10
12
2-1/2
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY.
1. Use a jockey pump only to fill the system at a velocity fill rate of less than 2' (0.61 m) per second.
CAUTION: Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer
effect that could damage sprinklers and piping components. See Warning above.
2. At all tees and greens use quick coupler keys with quick coupler valves to bleed air from the system lines during the filling
process. For best results, do not compress air and then relieve it – bleed the air constantly while filling the system.
3. After water has filled all lines and all air is removed, remove the quick coupler keys.
Pilot Valve Operation (Electric Models Only) ________________________________________
The pilot valve controls the operation of the main valve located in the
base of the sprinkler body. The main valve is operated by the release
Figure 3
of water metered through the pilot valve when it is activated either
100 PSI
manually at the sprinkler or by the irrigation system controller.
2
(7.0 kg/cm )
The sprinkler operation mode is set using a Toro Selector Tool
(P/N 995-15) inserted through the body flange onto the pilot valve
D-shaped selector cam. The "AUTO" mode permits automatic
80 PSI
(5.6 kg/cm )
operation from the system controller. The "ON" mode opens the main
valve for manual operation and "OFF" mode prevents the main valve
from opening.
2
The pilot valve regulates the water pressure to the sprinkler nozzle.
Pressure regulation compensates for large variations within the
system and maintains a constant pressure for optimum sprinkler
operation. The pilot valve is factory set to regulate one of four
pressure levels: 50 psi (3.4 bar), 65 psi (4.5 bar), 80 psi (5.5 bar) or
100 PSI (6.9 bar).
65 PSI
(4.6 kg/cm )
2
2
50 PSI (3.5 kg/cm )
Change the pilot valve operating pressure by loosening the thumb
screw that secures the selector lever. Position the selector lever to
the desired operating pressure and hand-tighten the nut. See Figure 3.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Nozzle Trajectory Adjustment Procedure _______________________________________
Note: The nozzle trajectory is factory pre-set at 25 degrees.
1. Insert the multi-purpose tool (P/N 995-83) into the slot provided in the top of the cap. Pull the riser assembly up, then grasp the
assembly to hold it in the popped-up position.
2. Remove the cap retaining screw and cap.
3. Using a 5/8" nut driver (P/N 995-99), turn the nozzle/housing assembly left to select 15° trajectory as shown in Figure 4. Turn the
nozzle/housing assembly right to select 25° trajectory as shown in Figure 5.
4. Install the cap making sure the top the nozzle housing is correctly nested in the cap.
5. Install the cap retaining screw.
6 Activate the sprinkler to check the spray trajectory.
Figure 5
Figure 5
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting _________________________________________________________
■
Pilot Valve
Possible equipment failures with causes and corrective action are listed below.
PROBLEM
POSSIBLE CAUSE – CORRECTIVE ACTION
SPRINKLER WILL
NOT TURN ON
(a) No 24 VAC to coil assembly. (Electric Models)
– Measure voltage with a Digital Volt Meter (DVM). Check wiring and controller program.
– Refer to Controller Operating Instructions.
(b) Selector cam in "OFF" position.
– Set to "AUTO" position.
(c) Debris in pilot valve assembly.
– Disassemble and remove all debris. (See Servicing Pilot Valve page 11.)
(d) Insufficient pressure in controller supply line and/or sprinkler control tube. (N.C. Models)
– Check pressure.
SPRINKLER WILL
NOT SHUT OFF
(a) Constant 24 VAC from controller. (Electric Models)
– Check for voltage using a DVM. If voltage is present, disconnect wire.
If sprinkler closes, service controller. Refer to Controller Service Manual.
(b) Selector cam in manual "ON" position.
– Set to "AUTO" or "OFF" position.
(c) Debris in pilot valve assembly.
– Disassemble and remove all debris. (See Servicing Pilot Valve page 11.)
(d) Constant pressure from controller. (N.C. Models)
– Check pilot valve at controller for constant flow.
– Check elevation differential. Valve elevation should not exceed 0' above
controller elevation or 70' (21.3 m) below controller elevation.
■
Sprinkler Assembly
PROBLEM
POSSIBLE CAUSE – CORRECTIVE ACTION
SPRINKLER WON'T ROTATE
(a) Debris wedged between stator and turbine.
– Remove obstruction.
(b) Drive assembly defective.
– Replace drive assembly.
(c) Nozzle base assembly defective.
– Replace nozzle base assembly.
(a) Dirt in riser assembly.
HEAD STICKS UP
– Flush out. (See Flushing Procedure on page 11.)
(b) Damaged or missing return spring.
– Replace.
(c) Damaged riser.
– Replace.
(a) Nozzle plugged with debris.
– Clean or replace nozzle.
POOR DISTRIBUTION PATTERN
(b) Nozzle orifice damaged.
– Replace nozzle.
(c) Low operating pressure.
– Determine why system overloaded and correct.
■
Main Valve
PROBLEM
VALVE WON'T CLOSE
(Electric )
POSSIBLE CAUSE – CORRECTIVE ACTION
(a) Continuous 24 VAC to sprinkler.
– Check controller for voltage source.
(b) Leak in pilot valve assembly.
– Replace pilot valve assembly.
(c) Plugged supply screen on piston.
– Clean or replace screen.
(d) Manual control selector on pilot valve assembly turned to "ON" position.
– Turn to "AUTO" position.
(e) Plunger movement restricted.
– Inspect and clean or replace.
(f) Valve cylinder misaligned with sprinkler body communication tube.
– Remove valve assembly and install correctly.
(g) Foreign object keeping valve from seating.
– Remove, clean and check valve for damage. Replace if necessary.
(h) Damaged piston seal or piston assembly.
– Replace valve assembly.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
VALVE WON'T CLOSE
(Hydraulic)
(a) Leak in control tubing.
– Isolate and repair.
(b) Pilot valve leak in controller.
– Confirm by observing constant dripping from discharge line of controller.
Refer to Controller Service Manual.
(c) Valve cylinder misaligned with sprinkler body communication tube.
– Remove valve assembly and install correctly.
(d) Foreign object keeping valve from seating.
– Remove, clean and check valve for damage. Replace if necessary.
(e) Damaged piston seal or piston assembly.
– Replace valve assembly.
VALVE WON'T OPEN
(Electric)
(a) Control (field) wires severed.
– Isolate and repair.
(b) No power to controller.
– Establish controller power.
(c) No power from controller to solenoid.
– Check for blown fuse and replace.
(d) Manual control selector on pilot valve assembly turned to "OFF" position.
– Turn to "AUTO" position.
(e) Pilot valve solenoid inoperative.
– Remove and replace.
(f) Pilot valve plunger movement restricted.
– Inspect, clean and/or replace.
(g) No supply from main valve.
– Debris in control tube, main valve assembly and/or communication passages in
body. Flush thoroughly.
VALVE WON'T OPEN
(Hydraulic)
(a) Plugged controller discharge line or discharge port in pilot valve.
– Verify by checking for discharge at discharge line when station is
activated. If no discharge, refer to Controller Service Manual.
SPRINKLER WEEPING
(Slow leak in valve)
(a) Damaged or blocked valve seat.
– Remove blockage and, if necessary, replace valve assembly.
(b) Damaged piston seal or piston assembly.
– Replace valve assembly.
(c) Low pressure on supply line .
– Check for low pressure reason and correct.
(d) Elevation of normally closed sprinkler exceeds 75' (22.9 m) differential.
SEVERAL VALVES ON DIFFERENT (a) Control tubing leak which lowers supply pressure to other stations.
STATIONS FAIL TO CLOSE
(Hydraulic)
– Turn controller from station to station until a station is reached where
only valves on that station stay open. The leak would be in the tubing
on that station. Isolate and repair.
(b) Leak in supply line to controller.
– Verify by checking pressure in all control lines.
(c) Leak in controller pilot valve.
– Verify by constant discharge from controller.
(d) Plugged supply line filter.
– Replace filter if more than 3 psi (0.21 bar) differential exists.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Servicing Procedures ____________________________________________________
The DT series sprinklers are designed to provide the user trouble-free operation for many years without scheduled maintenance. If it
becomes necessary to disassemble the sprinkler to correct a malfunction or replace a component, all internal parts of the sprinkler
can be accessed from the top. Refer to the Troubleshooting Procedure in this manual in the event of a malfunction. Some special
tools are required for disassembly and/or maintenance of the sprinkler and are available from your Toro dealer.
Servicing Sprinkler Mechanism
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY.
Note: Refer to Figure 6 for the following procedure:
Figure 6
1. Insert hooked end of multi-purpose tool (P/N 995-83)
into slot provided in top of cap (3). Pull assembly
upward, grasp and hold in position.
2. Insert hooked end of multi-purpose tool into slot in
snap ring (11). Pull snap ring inward toward the
sprinkler assembly, then upward to remove from the
snap ring groove in sprinkler body. Pull riser assembly
out of sprinkler body.
3. Use a 5/8" nut driver (P/N 995-99) to unscrew main
nozzle (10).
4. Remove cap screw (1) and cap (3).
5. Grasp return spring (14) and riser (16) firmly and hold
in place while removing nozzle base (4). Turn nozzle
base assembly counterclockwise to remove.
6. Carefully release tension from return spring (14).
7. Remove spring and seal retainer/o-ring assembly
(12 and 13).
8. Remove o-ring (13).
9. Remove rock screen (19) turning it counterclockwise
with edge of multi-purpose tool or tips of snap ring
pliers (P/N 995-100).
10. Remove drive assembly (17) and stator (18) from
riser assembly by carefully pressing on end of
threaded shaft.
11. Using a 5/16" nut driver (P/N 995-105), unscrew
intermediate nozzle (5 & 6) and inner nozzle (5) and
plugs (7) from the nozzle base assembly.
12. Thoroughly clean and inspect all parts and replace
as necessary. Reassemble in the reverse order.
Note: During reassembly, ensure snap ring is
correctly installed and fully seated in snap ring groove
before operating sprinkler. See WARNING above..
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Servicing Main Valve
WARNING
IF THE VALVE SNAP RING IS DIFFICULT TO REMOVE, RESIDUAL WATER PRESSURE MAY BE
REMAINING IN THE SYSTEM. TO PREVENT POSSIBLE SERIOUS INJURY DUE TO VALVE BEING
EJECTED UPWARD UNDER PRESSURE, CONFIRM THE FOLLOWING CONDITIONS EXIST PRIOR TO
REMOVING THE SNAP RING AND VALVE:
A. WATER SUPPLY TO SPRINKLER IS SHUT OFF AT SOURCE.
B. All PRESSURE IS BLED FROM SYSTEM, INCLUDING CONTROL TUBES.
C. AC POWER IS DISCONNECTED AT SOURCE.
1. See WARNING above. To remove valve assembly, squeeze
Figure 7
Figure 8
snap ring ears together with snap ring pliers (P/N 995-100) and
remove snap ring from sprinkler body. See Figure 7.
2. Use valve removal tool P/N 995-08 for DT34 or 995-09 for DT54
to remove valve assembly from base of sprinkler body. Valve
removal tool is inserted into sprinkler body and pushed through
valve ribs. A slight twist will catch tool under ribs enabling valve
removal by pulling straight up and out. See Figure 8.
Note: If valve removal tool is not available, use snap ring pliers
to grasp rib of valve cylinder assembly and pull up and out of
sprinkler body.
3. Reinstall valve assembly using valve insertion tool P/N 995-76
for DT34 or 995-101 for DT54 as follows:
• Load snap ring on insertion tool carrier with stepped side
against carrier as shown in Figure 9. While holding snap ring in
compressed position, slide retainer clip in to hold snap ring ears
• Load valve assembly on carrier as shown.
• Locate position of communication tube in bottom of sprinkler body and orient insertion tool accordingly.
• Insert tool straight down into sprinkler body aligning bosses on t-handle with holes on sprinkler body flange. When valve
assembly clears vertical side wall ribs inside body, pull up on snap ring release mechanism (DT54 models only) and press valve
assembly into position. Snap ring will lock into groove when properly installed. Remove insertion tool and check snap ring to
confirm that it is fully seated in groove.
Figure 9
Snap Ring In
Retainer Clip
Snap Ring Release
Mechanism
Stepped Side
of Snap Ring
Valve Assembly
Orientation In Carrier
Valve Assembly
Pressed Into Position
Snap Ring
Released
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Servicing Pilot Valve
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED, DURING
MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE PROCEDURES. DIRECT
CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED SPRINKLER CONNECTION OR
SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER PRESSURE CAN CAUSE SERIOUS INJURY.
Note: Refer to Figure 10 for the following procedure.
1. Make sure that the water supply to sprinkler
Figure 10
is positively shut off and any residual
pressure has been bled off. If the sprinkler is
pressurized, main valve will open when the
pilot valve is disconnected from control tube.
15
9
2. Carefully remove turf and soil from the side
of the sprinkler to expose pilot valve and
control tubing.
14
10
13
8
12
11
6
3. Remove the two retaining screws from the
pilot valve housing.
16
4. Pull the pilot valve assembly away from the
sprinkler body and cut the control tubing just
below tube retainer. Unless pilot valve has
been previously removed, control tubing
length will be sufficient for re-connection.
1
2
7
5
17
18
5. Remove tube retainer and remaining piece
of control tubing from valve body fitting.
3
6. Remove the solenoid (1, 2 or 3) by turning it
counterclockwise.
4
7. Remove the retaining nut (18) and washer
(17) from the pressure adjuster (11) and pull
the pilot valve body assembly out of housing
(16).
8. Remove diaphragm assembly (15), piston
(14), spring (13), traveling adjuster (12),
pressure adjuster (11) and o-ring (7).
9. Remove selector shaft assembly (9) and plunger assembly (5). (The selector shaft retains the plunger in the valve body.)
10. Thoroughly clean and inspect all parts. Replace damaged parts as necessary and reassemble in reverse order.
Note: Refer to Illustrated Parts Breakout Book, form number 368-0044 for service part numbers.
Flushing Sprinkler _______________________________________________________________
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED, DURING
MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE PROCEDURES. DIRECT
CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED SPRINKLER CONNECTION OR
SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER PRESSURE CAN CAUSE SERIOUS INJURY.
1. With sprinkler operating, carefully step down on center of cap several times. Water will flow around riser and flush out debris.
2. Cycle sprinkler on and off several times to check for proper retraction. Cap should be even with top of body flange when fully
retracted. If riser sticks in up position, check for debris lodged between riser and body. Flush out all debris. Remove sprinkler
mechanism if necessary.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
Form Number 373-0423 Rev. 2
Download from Www.Somanuals.com. All Manuals Search And Download.
|