Tornado Vacuum Cleaner 98190 User Manual

TORNADO INDUSTRIES  
7401 W. LAWRENCE AVENUE  
CHICAGO, IL 60706  
(708) 867-5100 FAX (708) 867-6968  
?
Tornado  
Operation & Maintenance Manual  
For Commercial Use Only  
Marathon 2000 Forward Only Extractor  
CATALOG NO.  
98190 (115V, 60 HZ)  
For parts list see L8190GHP  
Effective 12/19/2005  
L8190GH Revised 12/05 @2006 Tornado Industries All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Write your machine’s serial number here:_________________________________  
This illustrated instruction book covers:  
CATALOG NO.  
SERIES  
98190  
H
SIZE  
22”  
CAPACITY  
VOLTS  
AMPS  
20 Gal.  
115V  
15  
All specifications are subject to change without notice.  
TABLE OF CONTENTS:  
Warranty  
4
Safety Instructions  
Preparation & General Precautions  
Cleaning Tips  
5
6
9
Machine Specifications  
Operation Instructions  
Maintenance Issues  
Troubleshooting Table  
11  
12  
14  
16  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thank you for choosing Tornado products. We are proud to offer the most  
complete line of commercial and industrial cleaning equipment in the industry.  
Our reputation for quality, innovation and durability is unsurpassed.  
* Effective January 1 st, 2005. Terms subject to change without notice.  
1) Windshear™ Blower-Dryer, Insulation Blowers, T191, T201, T12/1, CV 30, CV 38, CW 50, CW  
100, Pro PAC Vacs, Duo-Upright Carpetkeepers™, and all chargers are warranted for 1 (one)  
year for both parts and labor.  
2) Warranties on all riding sweepers including the ICC1, KM 100/100 R, KMR 1250, and KMR  
1700 are 24 months parts/6 months labor OR 1000 hours of operation, whichever comes  
first. Warranties on the 75/140 & 90/140 are 24 months parts/12 months’ labor OR 1,000  
hours of operation whichever comes first.  
3) All non-wear item parts purchased after warranty expiration are warranted for 90 days.  
4) Warranty starts from the date of sale to the consumer or, at Tornado’s discretion, 6 months  
after dealer purchased the unit from Tornado, whichever comes first.  
Note: Tornado, The Latest Dirt, Floorkeeper, Carpetkeeper, Carpetrinser, Carpetrinser/Dryer,  
Headmaster, Taskforce, PAC-VAC, T-Lite, Glazer, Windshear, Max-Vac, CV 30, CV 38, and  
Trot-Mop are trademarks of Tornado Industries.  
1-800-VACUUMS  
Chicago area: (708) 867-5100  
Fax: (708) 867-6968  
7401 W. Lawrence Avenue  
Chicago, IL 60706  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
FOR COMMERCIAL USE  
WHEN USING AN ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOULD  
ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING:  
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE  
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:  
1.  
Do not leave machine when plugged in. Unplug from outlet when not in use  
and before servicing.  
2.  
3.  
Use indoors only. Do not use outdoors and do not expose to rain.  
Do not allow to be used as a toy. Close attention is necessary when used by  
or near children.  
4.  
5.  
Use only as described in this manual. Use only manufacturer’s  
recommended attachments.  
Do not use with damaged cord or plug. If machine is not working as it should,  
has been dropped, damaged, left outdoors, or dropped into water, return it to  
a service center.  
6.  
Do not pull or carry by cord, use cord as a handle, close a door on cord, or  
pull cord around sharp edges or corners. Do not run machine over cord.  
Keep cord away from heated surfaces.  
7.  
8.  
9.  
Do not unplug by pulling on cord. To unplug, grasp the plug not the cord.  
Do not handle plug or machine with wet hands.  
Do not put any object into openings. Do not use with any opening blocked;  
keep free of dust, lint, hair, and anything that may reduce air flow.  
10.  
Keep hair, loose clothing, fingers, and all parts of body away from openings  
and moving parts.  
11.  
12.  
13.  
Turn off all controls before unplugging.  
Use extra care when cleaning on stairs.  
Do not use to pick up flammable or combustible liquids, such as gasoline or  
use in areas where they may be present.  
14.  
Connect to a properly grounded outlet only. See Grounding Instructions.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAVE THESE INSTRUCTIONS  
BEFORE OPERATING THE MACHINE  
Read the manual carefully and completely before attempting to operate the unit.  
This manual has important information for the use and safe operation of the  
machine. Keep this manual on file and handy. This machine will assure years of  
satisfactory service if operated and maintained according to recommendations in  
the manual. If additional information is needed, please contact your local  
distributor or call:  
TORNADO INDUSTRIES, INC.  
7401 W. LAWRENCE AVE.  
CHICAGO, IL 60706  
708/867-5100  
FAX: 708/867-6968  
All information and specifications printed in the manual and parts list are current  
at the time of printing. However because of Tornado’s policy of continual product  
improvement, we reserve the right to make changes at any time without notice.  
This machine was shipped with window washer antifreeze, during the winter  
months, in the solution line system to protect the pump and valves from freezing  
during transportation and storage. Before you use the unit, rinse the solution line  
system with clean water (refer to Protect From Freezing).  
WARRANTY  
To protect your investment, promptly fill out the  
required information on the warranty card that  
comes with the unit and mail it back to  
Tornado Industries  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL PRECAUTIONS  
Make sure the machine is plugged into an electrical outlet with the same  
voltage and frequency rating as shown on the nameplate of the machine. Do  
not attempt to plug a 115-volt machine in a 230-volt outlet.  
Disconnect power cord from the outlet before attempting maintenance or  
repair work. Do not leave machine connected to an electrical outlet when  
unattended.  
Don’t abuse power cord. Never pull the machine by the cord or yank plug  
from the receptacle. If this machine is operated on a wet carpet a potential  
shock hazard can be caused by a damaged cord. Replace a damaged cord  
immediately.  
Do not immerse this machine in standing water. Such use can cause  
electrical shock.  
Do not use volatile substances such as gasoline or kerosene in the machine,  
on or near the surface to be cleaned. The use of such materials could cause  
an explosion and fire.  
If an extension cord is necessary, use a 3 conductor grounding cord, 12-  
gauge wire to prevent motor burnout, overheating of the wiring.  
To avoid electrical shock, do not expose to rain and store indoors.  
WARNING  
The machine was designed for use on carpeted floors as per instructions  
and recommendations written in this manual. Any deviation from its  
proper use or purpose and the consequential damage that may occur is the  
sole responsibility of the end user.  
Do not use the machine for dry vacuuming. This machine is not fitted with a  
dry filter.  
Use defoamer in the recovery tank at all times to prevent damaging the  
vacuum motor.  
Do not use water in excess of 140 degree F (62 degree C).  
Use only commercially available low foaming carpet cleaners and defoamers  
intended for machines of this type. Do not use dyes, bleaches, ammonia or  
other additives. The use of powdered cleaning solution if not diluted properly  
many result in the intake screen clogging or damage to the pump.  
Do not expose machine to freezing temperatures.  
Do not attempt to repair warranted machines. All repairs must be done by a  
qualified and authorized repair center. Non warranted repairs will be billed  
back to the owner of the unit.  
Do not use any replacement parts except those specified in the parts list.  
Unauthorized parts will void the warranty and could cause the unit not to  
function properly.  
FAILURE TO COMPLY WITH THE ABOVE WARNING INSTRUCTIONS  
WILL VOID THE WARRANTY  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL  
This machine operates on a standard, 15 AMP, 115 volt AC circuit and has a  
grounded plug.* Make sure the machine is connected to an outlet having the  
same configuration as the plug. No ungrounded adapter should be used with  
this machine.  
*Special voltage models available.  
GROUNDING INSTRUCTIONS  
This machine must be grounded. If it should malfunction or breakdown,  
grounding provides a path of least resistance for electric current to reduce the  
risk electric shock. This machine is equipped with a cord having an equipment -  
grounding conductor and grounding plug. The plug must be inserted into an  
appropriate outlet that is properly installed and grounded in accordance with all  
local codes and ordinance  
WARNING:  
Improper connection of the equipment-grounding conductor can result in a risk of  
electric shock. Check with a qualified electrician or service person if you are in  
doubt as to whether the outlet is properly grounded. Do not modify the plug  
provided with the appliance - if it will not fit the outlet, have a proper outlet installed  
by a qualified electrician.  
This machine is for use on a nominal 120-volt circuit, and has a grounding plug  
that looks like the plug illustrated in sketch A. A temporary adapter that looks like  
the adapter illustrated in sketches B and C may be used to connect this plug to a  
2-pole receptacle as shown in sketch B if a properly grounded outlet is not  
available. The temporary adapter should be used only until a qualified electrician  
can install a properly grounded outlet (sketch A). The green-colored rigid car, lug,  
or the like extending from the adapter must be connected to a permanent ground  
such as a properly grounded outlet box cover. Whenever the adapter is used, it  
must be held in place by a metal screw.  
NOTE: In Canada, the use of a temporary adapter is not permitted by the  
Canadian Electrical Code.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sketch A  
Sketch B  
Sketch C  
STRAIN RELIEF  
Attaching the strain relief/cord retainer to the 50’ power cord.  
1. Make a loop in power cord approximately 12” from receptacle end.  
2. Slide cord loop through slot in retainer and over retainer arm.  
Pull slack cord back through slot to secure. Attach retainer to handle.  
EXTENSION CORD  
If an extension cord is used, the wire size must be at least one size larger, (12-3)  
than the power cord on the machine.  
REQUIRED CLEANING CHEMICALS  
Use only commercial low foam cleaning chemicals that are designed for carpet  
extraction.  
1. General carpet extraction cleaner added to the solution tank.  
2. Traffic lane per-spray usually applied with spray wand.  
3. Defoamer only goes into the recovery tank.  
CAUTION: Use as directed. Do not over use the cleaning chemicals.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING TIPS  
Check the condition of the carpeting. If the carpet is loose, heavily soiled,  
stained, spotted or badly worn, point this out to the person in charge.  
Locate an inconspicuous spot on the area to be cleaned. Test carpet for  
colorfastness before proceeding. Pour the concentrated cleaning solution on  
the spot, cover with a white towel and place a heavy object on top to absorb  
the cleaning solution. Wait 10 minutes for any reaction to take place.  
Remove weight. If there is no color transfer, it should be safe to clean.  
Remove the furniture from the area to be cleaned. Large pieces can be  
moved to opposite end of the room from where you start cleaning and replace  
when it is completed. After cleaning carpet, place a small square of  
aluminum foil or 6-mil poly square under the furniture legs to prevent moisture  
from damaging the finish or rusting the metal glides.  
Clean the area first with a Clean-Air Carpetkeeper, upright vacuum. Do not  
use the Marathon 2000 as a dry vacuum! Heavily soiled carpet or areas of  
concentrated foot traffic should be treated with recommended pre-spotting or  
pre-spray chemicals, using a hand spray trigger bottle or pump up sprayer.  
Do not allow any spotter or pre-spray to dry on the carpet.  
Identify the type of carpet fiber to be cleaned. Most commercial carpet fibers  
in use are nylon or acrylic based. Best results in cleaning would be obtained  
if hot water is used to clean these types of fibers. On the other hand, hot  
water could shrink natural fiber carpeting, like wool and cotton in particular.  
Exercise caution when cleaning natural fibers. Use cool water test for  
colorfastness and apply the least amount of cleaning solution possible.  
Plan your cleaning route. Always try to have the cord to the right of the  
Marathon 2000 extractor so you are working away from the cord. Operate the  
extractor in parallel passes. Clean the perimeter last. Turn “off” spray switch  
in turns to conserve cleaning solution.  
To decrease dry time, go over the carpet without pressing carpet spray  
switch. To further decrease the drying time, use the Windshear 3000 Carpet  
Blower.  
When running the Marathon 2000 extractor, do not overfill the recovery tank.  
Do not allow the water level to rise above the clear dome on top of the  
recovery tank.  
If the spray jets become clogged, remove the spray bar assembly or the  
individual spray tips and soaks them in a mild acid or anti-browning chemical  
to dissolve normal alkaline chemical buildup.  
When the Marathon 2000 extractor runs out of cleaning solution, as noted by  
streaking or incomplete cleaning, turn off the machine and drain the recovery  
tank. Refill as needed and continue cleaning.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MACHINE SPECIFICATIONS  
ELECTRICAL: 115 V, 15 A, 60 HZ.  
DURABLE EXTENSION CORD: 75’  
DRIVE SYSTEM: TRANSAXLE W/ VARIABLE SPEED, (0-100 FT/MIN)  
VACUUM MOTOR: 3 STAGE, 1 HP., 120 CFM  
VACUUM SHOE: 22” WIDE, CAST ALUMINUM, ADJUSTABLE, FLOATING ARM  
BRUSH: 19” LONG  
BRUSH SPEED /HP: 1000 RPM / 1/4 HP  
SOLUTION PUMP: 100 PSI, DIAPHRAGM STYLE W/ VARIABLE FLOW  
(0.2GPM/2.0 GPM)  
SOLUTION CAPACITY: 20 GALLONS  
RECOVERY CAPACITY: 20 GALLONS  
WHEELS: FRONT (4” DIA.), REAR (10” DIA.)  
SPRAY SYSTEM: (4) QUICK CHANGE JETS, LEVER TRIGGER SPRAY WAND  
EMPTY WEIGHT: 190 LBS.  
FULL WEIGHT: 350 LBS.  
LENGTH: 51”  
HEIGHT: 37.5”  
WIDTH: 22”  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION INSTRUCTIONS  
Main Controls:  
Your Marathon 2000 extractor is equipped with (4) main switches, which  
control the spray bar, the brush motor, the vacuum motor and the main power.  
The main switch must be activated before operating the transaxle drive. The  
machine will glide easily across the floor when pushed forward (without power).  
The machine will also be able to be pulled back easily when the power is on or  
off. The pump spray and brush will only be activated when the deadman switch is  
squeezed.  
WARNING:  
In order to avoid injury, it is recommended that the Marathon 2000 extractor  
be pulled in the reverse direction (without power) in emergency situations  
only.  
In addition, there is (1) main circuit breaker, (located on the front of the main  
control panel):  
- (20 amp) circuit breaker – main power  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Up and Operation:  
Your Marathon 2000 is shipped complete and ready for carpet cleaning. This  
style of machine is sometimes referred to as a self-contained extractor, since  
everything is included in the body of the Marathon 2000 extractor.  
1. Install recovery tank cover to the top of the tank and connect the suction hose  
to the cover.  
2. Important! – Prior to first use: The unit has been tested with window washer  
fluid at the factory, and a small amount of this fluid may remain in the system  
as a precaution against freezing. Prior to first use, flush the tank and pump  
system with a half-gallon of plain water.  
3. Open filler door at the front of the tank and fill with hot water. Add liquid  
cleaning solution to proper dilution ratio.  
4. Use separate buckets to fill and empty extractor. Avoid using undissolved  
soap or chemicals that could potentially plug the spray jets.  
5. Attach a 12-gage extension cord to the pig tail plug on the machine.  
WARNING:  
To avoid serious injury: Plug into a grounded (earth) outlet only. Do not  
use an adapter or remove ground pin on plug. Do not use a damaged cord.  
6. Activate the main power switch. The LED light will be lit.  
7. Lower the manual release lever and allow the brush assembly to rest on the  
floor. The height of the suction nozzle may need to be adjusted using the turn  
knob.  
8. Activate the vacuum motor switch.  
9. Activate the brush motor switch.  
10.Activate the spray bar switch. Remember to turn off this switch about 6” from  
the end of each cleaning pass.  
11.Squeeze the trip lever on the main handle to move the extractor forward. The  
machine has a powered transaxle, so forward movement will be quick and  
easy. Turn the variable speed control clockwise to increase the forward  
speed. Note that the pump or brush will not operate until the machine is in  
motion and the spray and brush switches are turned on.  
12.As you are cleaning, monitor the water level in the recovery tank cover. An  
overflow of water in the recovery tank can damage the vacuum motor. Always  
be aware of this water level.  
13.The recovery tank can be drained by removing the drain hose from its support  
clip and removing the drain plug. The standpipe in the recovery tank is  
equipped with a metal screen cap. This cap is accessible by removing the  
clear dome on top of the unit. It is recommended that this cap be cleaned  
after every machine use.  
14.The solution tank has a clear see through drain hose, which tells the operator  
the tank level. The water in the solution tank can be drained using this hose.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15.While cleaning, pre-spray traffic areas and spots using the spray wand. The  
spray wand is attached to a quick disconnect and is pressurized when the  
MAIN SWITCH is turned on.  
WARNING:  
To avoid serious injury: Disconnect power before servicing. Electrical  
service must be performed by an authorized service station or electrician.  
Use only nonflammable commercial chemicals intended for machine  
application. Do not use where explosive vapors or dust are present in the  
air. Disconnect power if the machine is left unattended. Do not allow  
machine to freeze. Do not expose to rain, store machine indoors.  
Daily Maintenance:  
1. Rinse out the recovery tank and clean the recovery dome. In addition,  
remove and clean the recovery screen cap.  
2. Drain the solution tank and clean with water.  
3. Remove any debris in either the recovery or solution tank.  
4. Flush the pumping system with clean warm water or white vinegar.  
5. Remove lint or debris from the vacuum shoe or brush. Hint: if heavy lint  
build-up is present, use a hacksaw blade with teeth down to remove  
the lint.  
Periodic Maintenance:  
It is highly recommended that once a month you flush the Marathon 2000 out  
with a 8 to 1 ratio of water to white vinegar or anti-browning solution through  
the Marathon 2000 extractor. This will help to prevent the build up of alkaline  
residue.  
If the spray jets become clogged, remove and wash them thoroughly and  
blow dry. Do not use wire or pins to clean the nozzles as this will cause the  
spray pattern to become distorted, thereby creating a streaking pattern on the  
carpeting.  
If the spray jets drip after the pump is turned off, the solenoid valve may need  
to be cleaned.  
Once a month, inspect all electrical cables, hoses, filters and connections in  
the Marathon 2000. If you see something that should be repaired or replaced  
it should be reported and repaired. Little things are easy to forget about, but  
as these little things add up, you end up with a cluster of problems that will  
cost you in the long run.  
CAUTION: When opening the Marathon 2000 for service and/or inspection, be  
sure that the recovery hose is in its proper position. If not, the hose can  
become crushed and you will not get good airflow from the vacuum nozzle.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Be sure to use Tornado genuine parts and service is provided by an  
authorized Tornado Service Center. Use of non-O.E.M. parts will void the  
warranty.  
PROTECT FROM FREEZING - Caution!  
If it becomes necessary to store in temperatures that could drop below 40  
degrees F, the pumping system, hoses and valves must be protected from  
freezing with a methyl hydrate window washer antifreeze solution. Do not use  
ethylene glycol or cooling system antifreezes.  
Whenever unit will be stored in temperatures below 40 degrees F, empty the  
solution tank, and then pour a half-gallon of pre-mixed window washer antifreeze  
into the tank. The windshield washer fluid must not be diluted with water or  
solution already in the tank. Turn on the brush switch and press the spray switch  
until the unit runs completely dry.  
Before returning the unit back to service, allow it to reach room temperature first.  
Then add a half-gallon of plain water to the solution tank and flush the system  
using the spray switch.  
The unit has been tested at the factory with windshield washer antifreeze  
solution. A small amount of this solution may remain in the system and must be  
flushed out prior to first use.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting Table:  
Problem  
Solution  
No Power, Nothing Works  
* Plug in Cord, Check Circuit Breakers  
* Activate Main Power Switch  
* Check For Loose Wiring  
* Call Service  
Machine Will Not Move Forward  
Brush Does Not Rotate  
* Reset Circuit Breaker  
* Turn Speed Control Knob Clockwise  
* Call Service  
* Reset Circuit Breaker  
* Activate Brush Switch  
* Check For Loose Wiring  
* Call Service  
Poor Water Spray  
* Spray Jets Clogged-Remove Spray  
Bar and Clean Spray Jets  
* Check Pump-Remove Spray Bar  
And Check water Flow  
* Call Service  
Vacuum Motor Runs But Poor Suction  
Vacuum Motor Will Not Run  
* Remove Debris From Vac Shoe  
* Recovery Tank Too Full-Drain Tank  
* Remove Debris From Suction Hose  
* Call Service  
* Activate Vacuum Switch  
* Reset Circuit Breaker  
* Check For Loose Wiring  
* Call Service  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson TV VCR Combo XRB3059 A User Manual
Timex Heart Rate Monitor 117 095000 User Manual
Toshiba Computer Hardware TX39 User Manual
Toshiba DVD Player E 1 360E User Manual
Toshiba Power Supply RC803A HP1 User Manual
Tripp Lite Indoor Furnishings UPSHDEARKIT User Manual
ViewSonic Digital Photo Frame VS12978 User Manual
ViewSonic Flat Panel Television N2011 User Manual
ViewSonic Washer N2635W User Manual
Vulcan Hart Tiller VGLT 20 ML 52994 VGLT 30 ML 114955 VGLT 40 ML 52995 VGLT 60 ML 52996 User Manual