Tivoli Audio Portable Media Storage Version 3 Release 7 User Manual

Tivoli Storage  
Manager  
Messages  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tivoli Storage  
Manager  
Messages  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note!  
Before using this information and the product it supports, be sure to read the  
general information under “Notices” on page 1383.  
This publication is also available in a softcopy form that can be viewed with the  
IBM BookManager READ licensed program or the Adobe Acrobat Reader.  
Second Edition (April 2000)  
This edition applies to Version 3 Release 7 of the Tivoli Storage Manager for AIX , AS/400,  
HP-UX, Sun Solaris, Windows NT (5697-TSM and 5697-DRM); MVS and OS/390  
(5697-TSO and 5697-DRO); Tivoli Data Protection for Lotus Notes (5697-DPN), Tivoli Data  
Protection for Oracle (5697-DPO), Tivoli Data Protection for Microsoft SQL (5697-DPS),  
Tivoli Data Protection for Microsoft Exchange (5697-DPX), Tivoli Space Manager  
(5697-SPM) and to all subsequent releases and modifications until otherwise indicated in new  
editions.  
Order publications through your sales representative or the branch office serving your  
locality.  
Your feedback is important in helping to provide the most accurate and high-quality  
information. If you have comments about this book or any other Tivoli Storage Manager  
© Copyright International Business Machines Corporation 1993, 2000. All rights  
reserved.  
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA  
ADP Schedule Contract with IBM Corp.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Tivoli Storage Manager Messages  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tivoli Storage Manager Messages  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
vi  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Tivoli® Storage Manager (TSM) is a client/server program that  
provides storage management services to customers in a multivendor  
computer environment. TSM provides an automated, centrally  
scheduled, policy-managed backup, archive, and space management  
facility for file servers and workstations.  
This publication contains explanations and suggested actions for  
messages issued by the Tivoli Storage Manager server program for  
storage management services, the administrative client graphical user  
interface, administrative command line client, and backup-archive  
client.  
Messages Not Appearing in This Publication  
Message numbers in the range ANR0100–0120, and any with 9999  
are not published in this manual. They are considered severe errors  
and should be recorded and included in a problem report when  
contacting the service representative. The following messages are not  
published in this manual:  
Common  
Messages  
AIX Specific MVS Specific Windows NT HP-UX  
Sun Solaris  
Specific  
Specific  
Specific  
ANR0628I  
ANR0680E  
ANR0702E  
ANR0703E  
ANR0704E  
ANR1592E  
ANR1601E  
ANR2704E  
ANR2705E  
ANR2706E  
ANR2710E  
ANR2711E  
ANR2801E  
ANR2802E  
ANR7837S  
ANR7845S  
ANR7846S  
ANR7847S  
ANR7848S  
ANR7830E  
ANR7831I  
ANR7832E  
ANR7833I  
ANR7836S  
ANR7837S  
ANR7838S  
ANR7839E  
ANR7850S  
ANR7851S  
ANR7823S  
ANR7823S  
Tivoli Storage Manager Messages  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Common  
Messages  
AIX Specific MVS Specific Windows NT HP-UX  
Specific Specific  
Sun Solaris  
Specific  
ANR2830W  
ANR2840I  
ANR2845I  
ANR2846I  
ANR4024I  
ANR4400I  
ANR4401I  
ANR4696E  
Message number ANR7831I and numbers in the range  
ANR7900–8199 are AS/400® platform specific messages and are not  
publised in this manual. You can obtain the explanation for these  
messages using AS/400 commands such as WRKMSGD to get to the  
"Work with Message Descriptionspanel. The unpublished  
messages are:  
ANR7831I ANR7918I ANR7937I ANR7980E ANR7998E ANR8066E ANR8124E  
ANR7900E ANR7919E ANR7938E ANR7981E ANR7999E ANR8067E ANR8125E  
ANR7901E ANR7920E ANR7939E ANR7982E ANR8050E ANR8068E ANR8126I  
ANR7902E ANR7921E ANR7940E ANR7983E ANR8051I ANR8069E ANR8127E  
ANR7903E ANR7922E ANR7941E ANR7984E ANR8052I ANR8070E ANR8128E  
ANR7904E ANR7923E ANR7943E ANR7985I ANR8053I ANR8071E ANR8129E  
ANR7905E ANR7924E ANR7944E ANR7986E ANR8054E ANR8072E ANR8130E  
ANR7906E ANR7925E ANR7946I ANR7987I ANR8055I ANR8095E ANR8131E  
ANR7907E ANR7926E ANR7947I ANR7988I ANR8056E ANR8100I ANR8132E  
ANR7908E ANR7927E ANR7950E ANR7989E ANR8057E ANR8101E ANR8133W  
ANR7909E ANR7928E ANR7951E ANR7990E ANR8058E ANR8102E ANR8134W  
ANR7910I ANR7930I ANR7952E ANR7991E ANR8059E ANR8103I ANR8135E  
ANR7911I ANR7931I ANR7955I ANR7992E ANR8060E ANR8110I ANR8136I  
ANR7912S ANR7932I ANR7959E ANR7993I ANR8061E ANR8111I ANR8137I  
ANR7913S ANR7933I ANR7960E ANR7994I ANR8062E ANR8120I ANR8138I  
ANR7914E ANR7934I ANR7961E ANR7995I ANR8063E ANR8121I ANR8139I  
ANR7915E ANR7935I ANR7962E ANR7996E ANR8064E ANR8122I ANR8140E  
ANR7916E ANR7936I ANR7963E ANR7997E ANR8065E ANR8123I ANR8141I  
viii  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message numbers in the range ANE4000–4999 are client event  
logging messages. These messages (or events) are sent to the server  
for distribution to various event logging receivers. The client may  
send statistics to the server providing information about a backup or  
restore. These statistics are informational and self-explanatory  
messages that may be enabled or disabled to the various event  
logging receivers. The following messages are not published in this  
manual:  
ANE4950 ANE4951 ANE4952 ANE4953 ANE4954 ANE4955 ANE4956  
ANE4957 ANE4958 ANE4959 ANE4960 ANE4961 ANE4962 ANE4963  
ANE4964 ANE4965 ANE4966 ANE4967 ANE4968 ANE4969 ANE4985  
ANE4986 ANE4990 ANE4991 ANE4992 ANE4993 ANE4994  
information.  
Note: You may receive other messages that are not documented in  
this manual. Those messages may have been created after this  
manual was published. Use the online help facility to display  
the help text specific to the message.  
Softcopy Publications  
For the AIX® and Windows NT® operating systems, softcopy TSM  
publications are included with the TSM product code.  
The TSM library is available in softcopy on the following  
CD-ROMs:  
Title  
Order  
Number  
MVS Collection Kit  
SK2T-0710  
SK2T-2067  
SK2T-6700  
SK2T-0730  
VM Collection Kit  
OS/390 Collection Kit  
Transaction Processing and Data Collection Kit  
Tivoli Storage Manager Messages  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Tivoli Storage Manager Publications  
The following table list TSM server publications.  
Publication Title  
Order Number  
GC35-0382  
Tivoli Storage Manager Messages  
Tivoli Storage Management Products License  
Information  
LC23-4466  
Tivoli Storage Manager for AIX Quick Start  
GC35-0367  
Tivoli Storage Manager for AIX Administrators Guide GC35-0368  
Tivoli Storage Manager for AIX Administrators  
Reference  
GC35-0369  
GC26-7345  
GC35-0376  
GC35-0377  
GC35-0378  
LC23-4466  
Tivoli Storage Manager, S/390 Edition Licensed  
Program Specifications  
Tivoli Storage Manager for MVS and OS/390 Quick  
Start  
Tivoli Storage Manager for MVS and OS/390  
Administrators Guide  
Tivoli Storage Manager for MVS and OS/390  
Administrators Reference  
Tivoli Storage Management Products License  
Information  
Tivoli Storage Manager for Windows Quick Start  
GC35-0379  
GC35-0380  
Tivoli Storage Manager for Windows Administrators  
Guide  
Tivoli Storage Manager for Windows Administrators  
Reference  
GC35-0381  
LC23-4466  
Tivoli Storage Management Products License  
Information  
Tivoli Storage Manager for HP-UX Quick Start  
GC35-0370  
GC35-0371  
Tivoli Storage Manager for HP-UX Administrators  
Guide  
Tivoli Storage Manager for HP-UX Administrators  
Reference  
GC35-0372  
LC23-4466  
Tivoli Storage Management Products License  
Information  
x
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Publication Title  
Order Number  
GC35-0317  
Tivoli Storage Manager for AS/400 Quick Start  
Tivoli Storage Manager for AS/400 Administrators  
Guide  
GC35-0315  
Tivoli Storage Manager for AS/400 Administrators  
Reference  
GC35-0316  
LC23-4466  
GC35-0373  
Tivoli Storage Management Products License  
Information  
Tivoli Storage Manager for Sun Solaris Quick Start  
Tivoli Storage Manager for Sun Solaris Administrators GC35-0374  
Guide  
Tivoli Storage Manager for Sun Solaris Administrators GC35-0375  
Reference  
The following table list the TSM client publications.  
Publication Title  
Order Number  
Tivoli Space Manager for UNIX Using the Hierarchical SH26-4098  
Storage Management Clients  
Tivoli Storage Manager for Macintosh Using the  
Backup-Archive Client  
SH26-4103  
SH26-4105  
SH26-4099  
SH26-4100  
SH26-4101  
Tivoli Storage Manager for UNIX Using the  
Backup-Archive Clients  
Tivoli Storage Manager for OS/2 Using the  
Backup-Archive Client  
Tivoli Storage Manager for Netware Using the  
Backup-Archive Client  
Tivoli Storage Manager for Windows Using the  
Backup-Archive Client  
Tivoli Storage Manager Installing the Clients  
SH26-4102  
SX26-6021  
Tivoli Storage Manager Quick Reference for the  
Backup-Archive Clients  
Tivoli Storage Manager Trace Facility Guide  
SH26-4104  
Tivoli Storage Manager Using the Application Program SH26-4107  
Interface  
Tivoli Storage Manager Messages  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Publication Title  
Order Number  
Tivoli Storage Manager AFS/DFS Backup Clients  
SH26-4106  
The following table list Tivoli Data Protection publications.  
Order  
Publication Title  
Number  
Tivoli Data Protection for Informix Installation and User’s  
Guide  
SH26-4095  
Tivoli Data Protection for Lotus Domino, S/390 Edition  
Licensed Program Specifications  
GC26-7305  
Tivoli Data Protection for Lotus Domino, S/390 Edition Memo GH26-4094  
to Licensees  
Program Directory for Tivoli Data Protection for Lotus  
Domino, S/390 Edition  
GI10-4519  
Tivoli Data Protection for Lotus Domino for UNIX Installation SH26-4088  
and User’s Guide  
Tivoli Data Protection for Lotus Domino for Windows NT  
Installation  
GC26-7320  
Tivoli Data Protection for Lotus Notes on AIX Installation and SH26-4067  
User’s Guide  
Tivoli Data Protection for Lotus Notes on Windows NT  
Installation and User’s Guide  
SH26-4065  
SH26-4110  
SH26-4111  
SH26-4112  
Tivoli Data Protection for Microsoft Exchange Server  
Installation and User’s Guide  
Tivoli Data Protection for Microsoft SQL Server Installation  
and User’s Guide  
Tivoli Data Protection for Oracle for UNIX Installation and  
User’s Guide  
Tivoli Data Protection for Oracle for Windows NT Installation SH26-4113  
and User’s Guide  
Tivoli Data Protection for SAP R/3 Version 2.4 Installation  
and User’s Guide  
SH26-4109  
SC33-6388  
Tivoli Data Protection for SAP R/3 Version 2.7 Installation  
and User’s Guide  
xii  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Order  
Publication Title  
Number  
Tivoli Data Protection for Workgroups for Windows NT User’s GC35-0359  
Guide  
Tivoli Data Protection for Workgroups for NetWare User’s  
Guide  
GC32-0444  
Related AS/400 System Publications  
The following table lists related AS/400 publications.  
Publication Title  
Order Number  
SC41-3722  
SC41-3121  
SC41-3003  
SC41-3309  
OS/400 CL Reference  
AS/400 Local Device Configuration  
AS/400 Publications Reference  
AS/400 Automated Tape Library Planning and  
Management  
OS/400 Work Management  
SC41-3306  
SC41-3345  
SC41-3304  
SC41-3305  
SC41-3401  
SC41-3402  
Backup Recovery and Media Services for OS/400  
OS/400 Backup and Recovery – Basic  
OS/400 Backup and Recovery – Advanced  
OS/400 Communications Configuration  
OS/400 Remote Work Station Support  
Referenced MVS System Publications  
The following table list referenced MVS publications.  
Publication Title  
Order Number  
RACF Security Administrators Guide  
SC28-1340  
SC26-4932  
DFSMS/MVS DFSMSrmm Implementation and  
Customization Guide  
DFSMS/MVS DFSMSrmm Guide and Reference  
SC26-4931  
Tivoli Storage Manager Messages  
xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Related IBM® Hardware Products Publications  
The following table lists related IBM hardware products  
publications.  
Title  
Order Number  
IBM 3490 Magnetic Tape Subsystem Enhanced  
Capability Models E01 and E11 Users Guide  
GA32-0298  
IBM SCSI Tape Drive, Medium Changer, and Library  
Device Drivers: Installation and Users Guide  
GC35-0154  
IBM 3494 Tape Library Dataserver Operators Guide  
IBM Magstar 3590 Tape Subsystem Operators Guide  
GA32-0280  
GA32-0330  
GA32-0235  
IBM 3495 Tape Library Dataserver Models L20, L30,  
L40, and L50 Operators Guide  
IBM 3570 Magstar MP Tape Subsystem Operators  
Guide  
GA32-0345  
IBM International Technical Support Center  
Publications (Redbooks)  
The International Technical Support Center (ITSC) publishes  
redbooks, which are books on specialized topics such as using TSM  
to back up databases. You can order publications through your IBM  
representative or the IBM branch office serving your locality. You  
can also search for and order books of interest to you by visiting the  
IBM Redbooks home page on the World Wide Web at this address:  
http://www.redbooks.ibm.com/redbooks  
Referenced Publications  
The following table lists other publications referenced in this  
manual:  
Title  
Order  
Number  
MVS/ESA Programming: Authorized Assembler Services  
Guide  
GC28-1467  
xiv  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Title  
Order  
Number  
IBM 3494 Tape Library Dataserver User’s Guide: Media  
Library Device Driver for AS/400  
GC35-0153  
MVS/DFP V3R3 Macro Instructions for Data Sets  
IBM Local Area Network Technical Reference  
LAN Technical Reference IEEE 802.2 & NETBIOS APIs  
AS/400 System API Reference  
SC26-4747  
SC30-3383  
SC30-3587  
SC41-3801  
Software Developer’s Program  
The IBM Storage Systems Division (SSD) Software Developer’s  
Program provides a range of services to software developers who  
want to use the TSM application program interface (API).  
Information about the SSD Software Developer’s Program is  
available in the SSD Software Developer’s Program Information  
Package.  
To obtain the Software Developer’s Program Information Package:  
1. Call 800-4-IBM-SSD (800-442-6773). Outside the U.S.A., call  
408-256-0000.  
2. Listen for the Storage Systems Division Software Developer’s  
Program prompt.  
3. Request the Software Developer’s Program Information Package.  
Tivoli Storage Manager Web site  
All TSM publications are available on the TSM home page on the  
World Wide Web at the following address:  
http://www.tivoli.com/support/storage_mgr/tivolimain.html  
By accessing the TSM home page, you can access subjects that  
interest you. You can also keep up-to-date with the newest TSM  
product information.  
Tivoli Storage Manager Messages  
xv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Do You Have Comments or Suggestions?  
Your feedback is important in helping to provide the most accurate  
and high-quality information. If you have comments or suggestions  
for improving this publication, you can send us comments  
electronically by using these addressess:  
Internet: [email protected]  
Fax from U.S. and Canada: 520 799-2906  
Fax from other countries: (1) 520 799-2906  
You can also mail your comments to:  
International Business Machines Corporation  
Information Development, Department 61C  
9000 South Rita Road  
Tucson, Arizona 85744-0001, U.S.A.  
When you send information to IBM, you grant IBM a nonexclusive  
right to use or distribute the information in any way it believes  
appropriate without incurring any obligation to you.  
Translations  
Selected TSM publications have been translated into languages other  
than American English. Contact your service representative for more  
information about the translated publications and whether these  
translations are available in your country.  
xvi  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Summary of Changes for Tivoli Storage Manager  
This section summarizes changes made to the Tivoli Storage  
Manager product and this publication. Refer to the Tivoli Storage  
Manager Administrators Guide and the Tivoli Storage Manager  
Administrators Reference for details.  
Changes for Version 3 Release 7–April 2000  
Refer to the Tivoli Storage Manager Administrators Guide and the  
Tivoli Storage Manager Quick Start for a summary of additional  
changes to the current version of the product.  
For the latest information on requirements and compatibility among  
products, see this URL:  
Product Repackaging Changes–September 1999  
The ADSTAR® Distributed Storage Manager product and its features  
are now part of the Tivoli Storage Management product set. The  
table below shows the most important name changes. The transition  
of the entire product set to the new names may not be complete at  
the time of publishing, and as a result the terms ADSM and ADSTAR  
Distributed Storage Manager may still appear. For the latest  
information on requirements and compatibility among products, see  
Table 1. Product Name Changes  
Former name  
Current name  
Notes  
ADSTAR Distributed  
Storage Manager  
(ADSM)  
Tivoli Storage Manager Base product now  
(TSM)  
includes some functions  
that were purchased  
features for ADSM.  
Tivoli Storage Manager Messages  
xvii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1. Product Name Changes (continued)  
Former name  
Current name  
Notes  
Hierarchical Storage  
Management (HSM)  
client  
Tivoli Space Manager  
(also referred to as  
space manager client or now a separate product  
Formerly required  
purchase of a feature;  
HSM client)  
with Tivoli Storage  
Manager as the  
prerequisite.  
Disaster Recovery  
Manager (DRM)  
Tivoli Disaster  
Recovery Manager  
(DRM)  
Formerly required  
purchase of a feature;  
now a separate product  
with Tivoli Storage  
Manager as the  
prerequisite.  
ADSMConnect Agents Tivoli Data Protection  
for applications (also  
Formerly required  
purchase of a feature;  
now a separate product  
with Tivoli Storage  
Manager as the  
referred to as  
application clients)  
prerequisite.  
Changes for Version 3 Release 7–September 1999  
The following changes have been made for this edition:  
Creation of portable backup sets for clients  
The server can create portable backup sets for clients that are  
at the latest level of Tivoli Storage Manager. The function  
consolidates a client’s active backup files onto portable  
media that may be directly readable by the client’s system  
for restore operations.  
Logical volume backup for clients  
Backup-archive clients can now back up logical volumes to  
the Tivoli Storage Manager server.  
Performance enhancements  
Performance enhancements include the following:  
xviii  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Automatic tuning of selected server options  
Selected server options can be tuned automatically  
by the server.  
Database, recovery log, and all storage pool volumes  
TSM can specify a size from 0 to 64MB for VSAM  
I/O pages to allow a faster throughput of data for  
operations involving the database, the recovery log,  
and all storage pool volumes.  
Database page shadowing  
Database page shadowing mirrors every write to a  
database page so that the server can recover pages  
that have been partially written to should an outage  
occur that affects both mirrored volumes. Combined  
with the MIRRORREAD and MIRRORWRITE  
server options for the database and recovery log, you  
can specify your preferred level of protection,  
recoverability and performance.  
Database load and audit enhancements  
A new utility has been added to recover the contents  
of the database when the server is offline.  
Database snapshot  
You now have the choice of making a database snapshot,  
which is a full database backup to media that can be taken  
off-site. The database snapshot does not interrupt any  
database backup series and cannot have incremental database  
backups associated with it.  
Device support  
Enhancements to device support include:  
Control of tape drive cleaning  
Bulk tape check-in and check-out  
IBM 3494 Tape Library Dataserver  
Support for devices on a storage area network (SAN)  
IBM 3570 and 3575  
Removable media device type  
Tivoli Storage Manager Messages  
xix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Proxy Web services  
See Quick Start for details.  
Password expiration controls  
You can reset the password expiration period for all or  
selected users.  
Licensing changes  
Some features that formerly required the purchase of licenses  
are now part of the base Tivoli Storage Manager product.  
Changes for Version 3–January 1999  
The section on client messages has been reorganized. The following  
changes have been made for this edition:  
Client Common Messages (1000–1999)  
Various command-line client messages were moved from the  
client common messages to a new client message chapter  
titled Command-Line Client Messages  
Command-Line Client Messages (1053–3999)  
This is a new chapter.  
Enterprise Management (2500–2999)  
This is a new chapter.  
ADSMConnect Agent Messages  
This is a new section and includes the following chapters:  
ADSMConnect Agent for Lotus® Notes(0900–0999)  
ADSMConnect Agent for Microsoft® SQL Server  
(0301–5203) The messages begin with prefix ACO.  
ADSMConnect Agent for Oracle Backup (0410–0419)  
Changes for Version 3–September 1998  
The following changes have been made for this edition:  
Enterprise Administration  
You can manage a network of servers in a consistent way  
from a single, web browser-based administrative interface.  
You can set up one server as the configuration manager that  
distributes configuration information (such as policy) to  
xx  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
managed servers. In the network of servers you can route  
commands to one or more servers.  
Enterprise event logging and monitoring  
You can log events from other servers and clients to a  
specific ADSM server.  
Enterprise console  
The enterprise console is a web browser-based interface from  
which you can access ADSM server functions. When you  
log on to a configuration manager via the web interface, you  
access the enterprise console. The enterprise console can  
give the administrator a complete view of the ADSM  
installations in an enterprise. To use the web interface, you  
must have a browser with support installed for Java® 1.1.  
See ADSM Quick Start for more information.  
Enterprise logon  
From the administrative web interface, you can log on to an  
ADSM server once, and work with multiple servers to which  
you have administrative authority without having to log on  
again.  
ADSM server scripts  
You can create and store server scripts in the ADSM  
database. Scripts can contain ADSM administrative  
commands and can include conditional statements that  
evaluate the results of earlier commands in the script before  
proceeding. Scripts can be distributed to other servers and  
can be scheduled to run with the DEFINE SCHEDULE  
command.  
Database and recovery log automation  
You can set up triggers that automate increasing the size of  
the database or recovery log based on utilization levels.  
Storage pool migration by age  
You can set a minimum age for data before the server can  
migrate the data from a storage pool.  
Tivoli Storage Manager Messages  
xxi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disaster Recovery Manager plan file  
You can store the recovery plan file on another server to  
which your server has access via server-to-server  
communication.  
Changes for Version 3–March 1998  
The following changes have been made for this edition:  
Event logging and monitoring  
You can set up Simple Network Management Protocol  
(SNMP) as a hearbeat monitor and as a receiver for TSM  
event logging.  
Device support  
Device support has been enhanced to allow TSM to use the  
following devices:  
StorageTek SD-3 and 9490 tape drives. For these  
devices, use the device type of ECARTRIDGE.  
Tape libraries that are controlled by StorageTek  
Automated Cartridge System Library Software (ACSLS).  
Changes for Version 3–October 1997  
The new functions of TSM Version 3 are:  
Event logging and monitoring  
You can set up event logging of ADSM client and server  
events. See ADSM Administrators Guide and ADSM  
Administrators Reference for details.  
SQL queries of the ADSM database  
You can use SQL queries to get information about the  
ADSM server and clients. See ADSM Administrators Guide  
and ADSM Administrators Reference for details.  
Storing data on another ADSM server  
You can store data for one ADSM server (a source server)  
on another ADSM server (a target server). Using another  
ADSM server is especially useful for storing backups of the  
xxii  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ADSM database and ADSM storage pools. See ADSM  
Administrators Guide and ADSM Administrators Reference  
for details.  
Server file aggregation  
ADSM allows small client files to be combined and stored  
as larger aggregated files. Aggregation can improve  
performance and reduce database overhead. See ADSM  
Administrators Guide for details.  
Device support  
See ADSM Administrators Guide and ADSM Administrators  
Reference for details on the following enhancements.  
AIX  
Device support has been enhanced to allow ADSM to  
use the following devices:  
v
v
IBM 3570 tape devices.  
Optical devices that use 12-inch and 14-inch  
write-once optical cartridges.  
v
v
DTF tape devices.  
Tape devices that are supported by AIX device  
drivers (instead of ADSM device drivers). These  
devices have the device type of GENERICTAPE.  
A LABEL LIBVOLUME command allows you to label  
and check in volumes to an automated library in one  
step.  
Windows NT  
Device support has been enhanced to allow ADSM to  
use the following devices:  
v
v
IBM 3570 tape devices  
Optical devices that use 5.25-inch rewritable optical  
cartridges and 5.25-inch write-once optical cartridges  
v
DTF tape devices  
Tivoli Storage Manager Messages  
xxiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A LABEL LIBVOLUME command allows you to label  
and check in volumes to an automated library in one  
step.  
MVS  
Device support has been enhanced to allow ADSM to  
use IBM 3590 tape devices.  
HP-UX  
Device support has been enhanced to allow ADSM to  
use the following devices:  
v
v
IBM 3590 tape devices  
IBM 3494 automated tape library  
A LABEL LIBVOLUME command allows you to label  
and check in volumes to an automated library in one  
step.  
Sun Solaris  
Device class types now include support for IBM 3570  
and 3590 tape drives, quarter-inch cartridge (QIC) tape  
drives, digital linear tape (DLT) drives and libraries, and  
rewritable optical drives.  
A LABEL LIBVOLUME command allows you to label  
and check in volumes to an automated library in one  
step.  
Administrative client web interface  
You can access ADSM server functions from any  
workstation with a web browser that supports HTML 2.0 or  
higher. The workstation does not need to have an  
administrative client installed. See ADSM Quick Start for  
details.  
Immediate processing of commands on a client  
You can use an ADSM administrative command to run  
operations immediately on a client workstation. See ADSM  
Administrators Guide and ADSM Administrators Reference  
for details.  
xxiv  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Point-in-time restoration of client files  
Clients can restore files to a specific point in time if  
incremental backups have been performed and policy is set  
up appropriately. See ADSM Administrators Guide and  
ADSM Administrators Reference for details.  
Restarting client restoration sessions  
Clients can restart restore sessions that have been  
interrupted. Administrators can request information about  
these sessions and cancel them. See ADSM Administrators  
Guide and ADSM Administrators Reference for details.  
Defining client options at the server  
You can define sets of client options at the server, and assign  
a set to a client when registering the client. See ADSM  
Administrators Guide and ADSM Administrators Reference  
for details.  
Changing server options without stopping the server  
You can change some server options and have the changes  
take effect without stopping and starting the server. See  
ADSM Administrators Guide and ADSM Administrators  
Reference for details.  
Tivoli Storage Manager Messages  
xxv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xxvi  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I—Introduction  
Tivoli Storage Manager Messages  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Introduction  
Tivoli Storage Manager (TSM) is an enterprise-wide storage  
management application for the network. It provides automated  
storage management services to multivendor workstations, personal  
computers, and local area network (LAN) file servers. TSM includes  
the following components:  
Server  
Allows a server system to provide backup, archive, and  
space management services to workstations. The server  
maintains a database and recovery log for TSM resources,  
users, and user data.  
The server controls the TSM server’s storage, called storage  
pools. These are groups of random and sequential access  
media that store backed up, archived, and space-managed  
files.  
You can set up multiple servers in your enterprise network to  
balance storage, processor, and network resources. TSM  
allows you to manage and control multiple servers from a  
single interface that runs in a web browser (the enterprise  
console).  
Administrative client  
Allows administrators to control and monitor server  
activities, define management policies for client files, and set  
up schedules to provide services at regular intervals.  
Administrative functions are available from an administrative  
client command line and from a web browser interface.  
Tivoli Storage Manager Messages  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Backup-archive client  
Allows users to maintain backup versions of their files,  
which they can restore if the original files are lost or  
damaged. Users can also archive files for long-term storage  
and retrieve the archived files when necessary. Users or  
administrators can register workstations and file servers as  
client nodes with an TSM server.  
Hierarchical storage management (HSM) client  
Provides space management services for workstations on  
some platforms. TSM users can free workstation storage by  
migrating less frequently used files to server storage. These  
migrated files are also called space-managed files. Users can  
recall space-managed files automatically simply by accessing  
them as they normally would.  
Application programming interface (API)  
Allows users to enhance existing applications with backup,  
archive, restore, and retrieve services. When users install the  
TSM API client on their workstations, they can register as  
client nodes with an TSM server.  
This chapter contains information to help you understand the  
messages issued by the Tivoli Storage Manager (TSM):  
Server program  
Administrative client graphical user interface  
Administrative command line client  
Backup-archive client  
Space-management client  
Messages can appear on the server console, the administrative client,  
an operator terminal, the administrative graphical user interface, the  
backup-archive client, or the space-management client.  
TSM provides an activity log to help the administrator track server  
activity and monitor the system.  
The activity log contains messages generated by the server and is  
stored in the database. To access the activity log from the  
administrative graphical user interface, select the SERVER icon. The  
4
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
server automatically deletes messages from the activity log after they  
have passed the specified retention period. Any messages sent to the  
server console are stored in the activity log. Examples of the types  
of messages stored in the activity log include:  
When client sessions start or end  
When migration starts or ends  
When backed up files are expired from data storage  
Any output generated from background processes  
Understanding Messages  
The following examples illustrate the format used in this publication  
to describe TSM messages:  
Messages that begin with prefix ANE and are in range 4000–4999  
originate from the backup-archive client. These messages (or events)  
are sent to the server for distribution to various event logging  
receivers.  
The client may send statistics to the server providing information  
about a backup or restore. These statistics are informational  
messages that may be enabled or disabled to the various event  
logging receivers. These messages are not published in this manual.  
Messages that begin with prefix ANR originate from the server.  
Messages that begin with prefix ANS originate from the  
backup-archive or space management clients.  
ANS messages that are in range 5000–5999 and 8000–8999 originate  
from the administrative client.  
Messages that begin with prefix ACO and are in range 0301–5203  
originate from the administrative client. These are messages for  
Tivoli Data Protection Microsoft SQL Server.  
Message Format  
The following examples describe the TSM message format:  
Tivoli Storage Manager Messages  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The callouts to the right identify each part of the format.  
Message variables in the message text appear in italics. The server  
and client messages fall into the following categories:  
Common messages that pertain to all TSM server platforms  
Platform specific messages that pertain to each operating  
environment for the server and the client  
Messages that pertain to application clients  
How to Read a Return Code Message  
Many different commands can generate the same return code. The  
following examples are illustrations of two different commands  
issued that result in the same return code; therefore, you must read  
the descriptive message for the command.  
6
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Example One for QUERY EVENT Command  
Example Two for DEFINE VOLUME Command  
Tivoli Storage Manager Messages  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
Obtaining Help with Tivoli  
Storage Manager  
This section describes the following:  
How to obtain help with processing errors by using Internet and  
IBMLink/ServiceLink  
How to describe errors with keywords  
How to obtain online message help  
What information to have available when you contact your  
service representative  
Internet and IBMLink Assistance  
TSM message help explanations may suggest that you contact your  
service representative for additional help with processing errors.  
Online help is available through Internet and IBMLink/ServiceLink.  
Internet  
If your installation has access to the Internet, the latest server and  
client PTFs (maintenance updates) are available on the anonymous  
ftp (file transfer protocol) server. The machine name is  
index.storsys.ibm.com.  
IBMLink/ServiceLink  
If your installation has access to IBMLink/ServiceLink, an  
interactive online database program, you can:  
Tivoli Storage Manager Messages  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Search for an existing authorized program analysis report  
(APAR) that is similar to your problem.  
Search for an available program temporary fix (PTF) for the  
existing APAR.  
Order the PTF if it is available.  
Create an Electronic Technical Response (ETR) problem report  
to get assistance from an TSM service representative.  
Describing the Error with Keywords  
When you use IBMLink/Servicelink or call your service  
representative, accurately describe the problem so that the service  
representative may quickly help you solve the problem. Identify the  
processing error with a full set of keywords whenever possible. A  
keyword is a word or an abbreviation used to describe a single  
aspect of a program failure. Each keyword describes an aspect of a  
processing error.  
The following example displays the necessary set of keywords:  
56480200n R312 type command function  
Where  
Represents  
56480200n  
R312  
type  
command  
function  
Component identification keyword  
Release level keyword  
Type-of-failure keyword  
Command keyword  
Function keyword  
Component Identification Keyword  
The component identifiers for TSM are listed below:  
Server Platform Component ID  
DRM  
AIX  
AS/400  
HP-UX  
Sun Solaris  
5697-DRM  
5697-TSM  
5697-TSM  
5697-TSM  
5697-TSM  
10  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Server Platform Component ID  
Windows NT 5697-TSM  
MVS and OS/390 5697-TSO  
DRM for MVS  
and OS/390  
5697-DRO  
Type-of-Failure Keyword  
The following keywords identify the type of failure that may occur:  
Keyword  
Description  
ABENDxxx  
INCORROUT  
Use this keyword when the system ends abnormally.  
Use this keyword when incorrect output is received or  
expected output is missing.  
LOOP  
Use this keyword if a part of the program code runs  
endlessly; include situations in which a part of the  
output repeats continuously.  
MSGANRnnnnt Use this keyword when a message:  
(or)  
Indicates an internal program error  
MSGANSnnnnt  
Is issued in a set of conditions that should not  
cause it to be issued  
Contains invalid or missing data  
description of the message format.  
WAIT  
Use this keyword when you receive no response within  
a reasonable time that can be perceived as poor  
response or poor performance.  
xxxxxxxxxx  
Use this keyword when a programming problem  
(Documentation) appears to be caused by incorrect, missing, or  
ambiguous information in one of the TSM publications.  
Enter the order number of the publication in place of  
xxxxxxxxxx. Include the letter prefix and version  
number, but omit all hyphens, for example,  
GC35038200. Refer to “Tivoli Storage Manager  
Publications” on page x for a list of the TSM  
publications.  
PERFM  
Use this keyword as a closing code for an APAR.  
Tivoli Storage Manager Messages  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Command Keyword  
Build keywords based on TSM commands. Refer to Administrators  
Reference for a list of the commands.  
Function Keyword  
Use keywords that refer to basic TSM functions such as backup,  
retrieve, archive, recover, migrate, and export-import.  
Obtaining Online HELP (Get Help on Error Messages)  
Use the HELP command on the server console or administrative  
command line client to display information about server and  
administrative command line client messages. Use the HELP  
command on the backup-archive client to display information about  
backup-archive client messages.  
The Help error message number command displays the help text  
specific to the error message. You can get help information on server  
messages (prefixed by ANR), and administrative command line and  
backup-archive client messages (prefixed by ANS or ANE) except  
those specific to the administrative graphical user interface client.  
Contacting Your Service Representative  
When you contact your service representative after the proper  
diagnostic procedures have been followed and user specifications  
have been checked for accuracy, you should have on hand the  
Running Trace Commands  
Your service representative may request that you run trace  
commands to perform diagnostic functions. The output from the  
trace commands is classified as Diagnosis, Modification, and Tuning  
Information.  
12  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Messages That Do Not Appear in This Publication  
information about messages that appear online but are not  
documented in this publication.  
Tivoli Storage Manager Messages  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
14  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II—Server Messages: Common  
and Platform Specific (ANR);  
Client Events Logged to  
Server (ANE)  
Tivoli Storage Manager Messages  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
16  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Common and Platform Specific  
Messages (ANR0100–ANR9999)  
This chapter contains the common and platform-specific server  
messages. The organization of the messages are grouped by the  
message prefix ANR and documented in ascending numeric order. If  
a message is platform specific and a duplicate, the appropriate  
platform name is added after the message number and it is also  
documented alphabetically by platform name.  
ANR0100E  
Source file(line number): Error error code creating table table name.  
Explanation: An internal error has occurred in an attempt to create a server  
database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
ANR0101E  
Source file(line number): Error error code opening table table name.  
Explanation: An internal error has occurred in an attempt to access a server  
database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANR0102E  
ANR0103E  
ANR0104E  
ANR0105E  
ANR0106E  
Source file(line number): Error error code inserting row in table table name.  
Explanation: An internal error has occurred in an attempt to add data to a server  
database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
Source file(line number): Error error code updating row in table table name.  
Explanation: An internal error has occurred in an attempt to update data in a  
server database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
Source file(line number): Error error code deleting row from table table name.  
Explanation: An internal error has occurred in an attempt to remove data from a  
server database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
Source file(line number): Error setting search bounds for table table name.  
Explanation: An internal error has occurred in an attempt to access data in a  
server database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
Source file(line number): Unexpected error error code fetching row in table table  
name.  
Explanation: An internal error has occurred in an attempt to access data in a  
server database table. This message always accompanies another error message and  
provides more detail about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
18  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0107W  
ANR0108E  
ANR0110E  
Source file(line number): Transaction transaction ID was not committed due to  
an internal error.  
Explanation: An internal error was detected during transaction commit. This  
message should be preceded by another error message which provides more detail  
about that error.  
System Action: The activity that generated this error fails.  
User Response: Contact your service representative.  
Source file(line number): could not start a new transaction.  
Explanation: An error occurred while attempting to start a new transaction.  
Possibly there is not enough memory.  
System Action: The activity that generated this error fails.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
An unexpected system date has been detected; the server is disabled. Use the  
ACCEPT DATE command to establish the current date as valid.  
Explanation: The server has noted that the current system date is suspect. It is  
earlier than the server install date or has suddenly moved into the future by 30 days  
or more.  
System Action: The server is disable for client access. Server expiration will not  
execute.  
User Response: If the current system date is not valid, reset the date. Use the  
ACCEPT DATE command to establish the current date as valid on the server. After  
executing this command, you can use the ENABLE SESSIONS command to enable  
the server for client sessions.  
ANR0130E  
DiagnosticID: Server LOG space exhausted.  
Explanation: There is no space to write data to the server recovery log.  
System Action: The activity that generated this error fails.  
User Response: To increase the amount of log space available to the server, an  
authorized administrator can add log volumes by using the DEFINE LOGVOLUME  
command, and extend the size of the log by using the EXTEND LOG command.  
Tivoli Storage Manager Messages  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0131E  
DiagnosticID: Server DB space exhausted.  
Explanation: There is no space to write data to the server database.  
System Action: The activity that generated this error fails.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes by using the DEFINE  
DBVOLUME command, and extend the size of the database by using the EXTEND  
DB command.  
ANR0132E  
DiagnosticID: Memory allocation failed: object object name, size size.  
Explanation: The server cannot obtain enough memory to create the object  
named.  
System Action: The activity that generated this error fails.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0200I  
ANR0201I  
ANR0202W  
Recovery log assigned capacity is size megabytes.  
Explanation: The amount of space allocated to the recovery log is shown.  
System Action: None.  
User Response: None.  
Database assigned capacity is size megabytes.  
Explanation: The amount of space allocated to the database is shown.  
System Action: None.  
User Response: None.  
Database volume volume name varied offline due to excessive read errors.  
Explanation: The database volume shown has been varied offline because too  
many read errors have been encountered.  
System Action: If available, a mirrored copy of the volume is used.  
User Response: Correct the cause of the read errors.  
20  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0203W  
ANR0204W  
ANR0205W  
ANR0206W  
Database volume volume name varied offline due to excessive write errors.  
Explanation: The database volume shown has been varied offline because too  
many write errors have been encountered.  
System Action: If available, a mirrored copy of the volume is used.  
User Response: Correct the cause of the write errors.  
Recovery log volume volume name varied offline due to excessive read errors.  
Explanation: The recovery log volume shown has been varied offline because too  
many read errors have been encountered.  
System Action: If available, a mirrored copy of the volume is used.  
User Response: Correct the cause of the read errors.  
Recovery log volume volume name varied offline due to excessive write errors.  
Explanation: The recovery log volume shown has been varied offline because too  
many write errors have been encountered.  
System Action: If available, a mirrored copy of the volume is used.  
User Response: Correct the cause of the write errors.  
Partial write detected on database volume volume name, logical page logical  
page number (physical page physical page number).  
Explanation: During a write of a database page, an error occurred so that the page  
was not completely written to disk.  
System Action: The failed I/O operation is retried on a mirrored volume.  
User Response: See accompanying messages for information about the volume in  
error.  
ANR0207E  
Page address mismatch detected on database volume volume name, logical page  
logical page number (physical page physical page number); actual: logical page  
number.  
Explanation: During a read of a database page, the page does not contain the  
expected page address.  
System Action: The failed I/O operation is retried on a mirrored volume.  
User Response: See accompanying messages for information about the volume in  
error.  
Tivoli Storage Manager Messages  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0208W  
Partial write detected on recovery log volume volume name, logical page logical  
page number (physical page physical page number).  
Explanation: During a write of a recovery log page, an error occurs so that the  
page is not completely written to disk.  
System Action: The failed I/O operation is retried on a mirrored volume.  
User Response: See accompanying messages for information about the volume in  
error.  
ANR0209E  
Page address mismatch detected on recovery log volume volume name, logical  
page logical page number (physical page physical page number); actual: logical  
page number.  
Explanation: During a read of a recovery log page, the page does not contain the  
expected page address.  
System Action: The failed I/O operation is retried on a mirrored volume.  
User Response: See accompanying messages for information about the volume in  
error.  
ANR0210S  
Inconsistency found in LVM data page page number - partial write detected.  
Explanation: During a write of an LVM internal page, an error occurs so that the  
page is not completely written to disk.  
System Action: The failed I/O operation is retried on a mirrored volume.  
User Response: See accompanying messages for information about the volume in  
error.  
ANR0211S  
Inconsistency found in LVM data page page number - page address mismatch  
(actual page number).  
Explanation: During a read of an LVM internal page, the page does not contain  
the expected page address.  
System Action: The failed I/O operation is retried on a mirrored volume.  
User Response: See accompanying messages for information about the volume in  
error.  
ANR0212E  
Unable to read disk definition file file specification.  
Explanation: At startup, the server cannot read the indicated file in order to obtain  
a list of disk volumes to mount.  
System Action: Server initialization fails.  
22  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use a text editor to recreate the file; it should contain one line  
with the name of a single log or database volume. Then restart the server.  
ANR0213W  
ANR0214W  
Unable to rewrite disk definition file.  
Explanation: An error occurs trying to update the disk definition file.  
System Action: None.  
User Response: Attempt to determine the cause of the write error and correct it.  
Database volume volume name is in the offline state - VARY ON required.  
Explanation: At system startup, the server finds that the specified database  
volume is in the offline state.  
System Action: The volume is not accessed.  
User Response: Determine the reason for the volume being offline; if possible,  
vary it online.  
ANR0215W  
ANR0216I  
ANR0217I  
Recovery log volume volume name is in the offline state - VARY ON required.  
Explanation: At system startup, the server finds that the recovery log volume  
shown is in the offline state.  
System Action: The volume is not accessed.  
User Response: Determine the reason for the volume being offline; if possible,  
vary it online.  
Database volume volume name is in the stalestate - synchronization process  
started.  
Explanation: At system startup, the server finds that the database volume shown  
is not synchronized.  
System Action: A process is started to synchronize the volume.  
User Response: None.  
Recovery log volume volume name is in the stalestate - synchronization  
process started.  
Explanation: At system startup, the server finds that the recovery log volume  
shown is not synchronized.  
System Action: A process is started to synchronize the volume.  
User Response: None.  
Tivoli Storage Manager Messages  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0218I  
ANR0219I  
ANR0220I  
Unable to install database volume volume name - capacity must be at least 5  
megabytes.  
Explanation: An attempt has been made to add a database volume that is smaller  
than the server minimum.  
System Action: The volume is not added.  
User Response: Increase the size of the volume or supply another larger volume.  
Unable to install recovery log volume volume name - capacity must be at least 5  
megabytes.  
Explanation: An attempt has been made to add a recovery log volume that is  
smaller than the server minimum.  
System Action: The volume is not added.  
User Response: Increase the size of the volume or supply another larger volume.  
Synchronization of database volume volume name started as process process ID.  
Explanation: A background process was started to synchronize the contents of the  
database volume shown with its copy volume. The background process was assigned  
the process ID shown.  
System Action: The background process starts to synchronize the volume and  
server operation continues.  
User Response: The administrator may query the status of the background process  
by using the QUERY PROCESS command, or cancel the process by using the  
CANCEL PROCESS command.  
ANR0221I  
Synchronization of recovery log volume volume name started as process process  
ID.  
Explanation: A background process was started to synchronize the contents of the  
recovery log volume shown with its copy volume(s). The background process was  
assigned the process ID shown.  
System Action: The background process starts to synchronize the volume and  
server operation continues.  
User Response: The administrator may query the status of the background process  
by using the QUERY PROCESS command, or cancel the process by using the  
CANCEL PROCESS command.  
24  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0222E  
ANR0223E  
ANR0224E  
Error action disk definition file file specification.  
Explanation: An error occurred creating or changing the disk definition file.  
System Action: None.  
User Response: Attempt to determine the cause of the write error and correct it.  
Error writing list of disks to disk definition file.  
Explanation: The disk definition file cannot be written.  
System Action: Installation ends.  
User Response: Determine the cause of the write error and correct it.  
Volume volume name is specified more than once - server installation failed.  
Explanation: The specified volume name was specified more than once in the  
server installation execution.  
System Action: Installation ends.  
User Response: Reinitialize the server install specifying a unique name for each  
database and recovery log volume.  
ANR0230E  
ANR0231E  
ANR0232I  
Synchronization process failed for database volume volume name.  
Explanation: The process that was attempting to synchronize the database volume  
shown has failed.  
System Action: The volume is in the stale state.  
User Response: See accompanying messages for more information.  
Synchronization process failed for recovery log volume volume name.  
Explanation: The process that was attempting to synchronize the recovery log  
volume shown has failed.  
System Action: The volume is in the stale state.  
User Response: See accompanying messages for more information.  
Synchronization process canceled for database volume volume name.  
Explanation: The process that was attempting to synchronize the database volume  
shown has been canceled.  
System Action: The volume is in the stale state.  
Tivoli Storage Manager Messages  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If desired, issue a VARY ONLINE command to start another  
synchronize process.  
ANR0233I  
Synchronization process canceled for recovery log volume volume name.  
Explanation: The process that was attempting to synchronize the database volume  
shown has been canceled.  
System Action: The volume is in the stale state.  
User Response: If desired, issue a VARY ONLINE command to start another  
synchronize process.  
ANR0234I  
ANR0235I  
ANR0240E  
ANR0241E  
Synchronization complete for database volume volume name.  
Explanation: The synchronization process for the database volume named has  
finished successfully.  
System Action: The volume is varied online.  
User Response: None.  
Synchronization complete for recovery log volume volume name.  
Explanation: The synchronization process for the recovery log volume named has  
finished successfully.  
System Action: The volume is varied online.  
User Response: None.  
Deletion process failed for database volume volume name.  
Explanation: The process that was attempting to delete the database volume  
shown has failed.  
System Action: The volume is not deleted.  
User Response: See accompanying messages for more information.  
Deletion process failed for recovery log volume volume name.  
Explanation: The process that was attempting to delete the recovery log volume  
shown has failed.  
System Action: The volume is not deleted.  
User Response: See accompanying messages for more information.  
26  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0242I  
ANR0243I  
ANR0244I  
ANR0245I  
ANR0246E  
Deletion process canceled for database volume volume name.  
Explanation: The process that was attempting to delete the database volume  
shown has been canceled.  
System Action: The volume is not deleted.  
User Response: None.  
Deletion process canceled for recovery log volume volume name.  
Explanation: The process that was attempting to delete the recovery log volume  
shown has been canceled.  
System Action: The volume is not deleted.  
User Response: None.  
Deletion complete for database volume volume name.  
Explanation: The delete process for the database volume named has finished  
successfully.  
System Action: The volume is deleted.  
User Response: None.  
Deletion complete for recovery log volume volume name.  
Explanation: The delete process for the recovery log volume named has finished  
successfully.  
System Action: The volume is deleted.  
User Response: None.  
Error reading logical page logical page number (physical page physical page  
number) from database volume volume name.  
Explanation: An error has been encountered when attempting to read a page from  
the specified database volume.  
System Action: The failed I/O operation is retried on a mirrored volume, if  
available.  
User Response: See accompanying messages for information about the volume in  
error. If the error persists and another mirrored copy of the volume is available, the  
failing volume should be taken offline by using the VARY OFF command, and  
repaired. Otherwise, halt the server and repair the volume. Then restart the server.  
Tivoli Storage Manager Messages  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0247I  
Database page logical page number successfully read from an alternate copy on  
volume volume name.  
Explanation: After a read error, the server is able to read the desired page from  
another synchronized mirrored volume.  
System Action: Processing continues.  
User Response: None.  
ANR0248E  
Unable to read database page logical page number from any alternate copy.  
Explanation: After a read error, the server is unable to read the desired page from  
another mirrored volume because no other mirrored volume is in the synchronized  
state. This message is normally preceded by a message indicating which volume  
failed.  
System Action: Processing is ended.  
User Response: You can repair the failed volume by halting the server and  
correcting the volume errors.  
ANR0249E  
Error reading logical page logical page number (physical page physical page  
number) from recovery log volume volume name.  
Explanation: An error has been encountered when attempting to read a page from  
the specified recovery log volume.  
System Action: The failed I/O operation is retried on a mirrored volume, if  
available.  
User Response: See accompanying messages for information about the volume in  
error. If the error persists and another mirrored copy of the volume is available, the  
failing volume should be taken offline, by using the VARY OFF command, and  
repaired.  
ANR0250I  
Recovery log page logical page number successfully read from an alternate copy  
on volume volume name.  
Explanation: After a read error, the server is able to read the desired page from  
another synchronized mirrored volume.  
System Action: Processing continues.  
User Response: None.  
28  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0251E  
Unable to read recovery log page logical page number from any alternate copy.  
Explanation: After a read error, the server is unable to read the desired page from  
another mirrored volume because no other mirrored volume was in the synchronized  
state. This message is normally preceded by a message indicating which volume  
failed.  
System Action: Processing is ended.  
User Response: You can repair the failed volume by halting the server and  
correcting the volume errors.  
ANR0252E  
Error writing logical page logical page number (physical page physical page  
number) to database volume volume name.  
Explanation: An error has been encountered when attempting to write a page to  
the specified database volume.  
System Action: If a mirrored volume is available then the failing volume is forced  
into the offline state.  
User Response: Repair the failing volume, and then use the VARY ON command  
to bring the volume back online.  
ANR0253E  
Unable to write database page logical page number to any alternate copy.  
Explanation: After a write error, the server is unable to write the desired page to  
another mirrored volume because no other mirrored volume is in the synchronized  
state. This message is normally preceded by a message indicating which volume  
failed.  
System Action: Processing is ended.  
User Response: Repair the failed volume.  
ANR0254E  
Error writing logical page logical page number (physical page physical page  
number) to recovery log volume volume name.  
Explanation: An error has been encountered when attempting to write a page to  
the specified recovery log volume.  
System Action: If a mirrored volume is available, the failing volume is forced into  
the offline state.  
User Response: Repair the failing volume, and then use the VARY ON command  
to bring the volume back online.  
Tivoli Storage Manager Messages  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0255E  
ANR0256E  
ANR0257E  
ANR0258E  
Unable to write recovery log page logical page number to any alternate copy.  
Explanation: After a write error, the server is unable to write the desired page to  
another mirrored volume because no other mirrored volume is in the synchronized  
state. This message is normally preceded by a message indicating which volume  
failed.  
System Action: Processing is ended.  
User Response: You can repair the failed volume by halting the server and  
correcting the volume errors.  
Error writing physical page physical page number to restart/checkpoint area on  
database volume volume name.  
Explanation: An error has been encountered when attempting to write a page to  
the specified database volume.  
System Action: If a mirrored volume is available, the failing volume is forced into  
the offline state.  
User Response: Repair the failing volume, and then use the VARY ON command  
to bring the volume back online.  
Error writing physical page physical page number to restart/checkpoint area on  
recovery log volume volume name.  
Explanation: An error has been encountered when attempting to write a page to  
the specified database volume.  
System Action: If a mirrored volume is available, the failing volume is forced into  
the offline state.  
User Response: Repair the failing volume, and then use the VARY ON command  
to bring the volume back online.  
Unable to write complete restart/checkpoint information to disk.  
Explanation: While writing restart/checkpoint information to disk, the server  
encounters an error writing to a database or recovery log volume for which no  
synchronized mirrored copy is available. This message is normally preceded by a  
message indicating which volume failed.  
System Action: Processing is ended.  
User Response: Repair the failing volume.  
30  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0259E  
Unable to read complete restart/checkpoint information from any database or  
recovery log volume.  
Explanation: During server restart, the server is unable to read a complete set of  
restart/checkpoint information from any of the defined database or recovery log  
volumes.  
System Action: Server restart is ended.  
User Response: Ensure that all defined database and recovery log volumes are  
available for use by the server.  
ANR0260I  
ANR0261I  
ANR0265E  
Database page logical page number successfully resynchronized.  
Explanation: After detecting a partially-written database page, the server is able to  
rewrite the page by using a synchronized mirror copy.  
System Action: Processing continues.  
User Response: None.  
Recovery log page logical page number successfully resynchronized.  
Explanation: After detecting a partially-written recovery log page, the server is  
able to rewrite the page by using a synchronized mirror copy.  
System Action: Processing continues.  
User Response: None.  
Log disk processing failed: sufficient memory is not available.  
Explanation: At server installation, the server is unable to process the server log  
disks due to insufficient memory.  
System Action: Server installation stops.  
User Response: Restart the server installation process with more memory  
available.  
ANR0266E  
Database disk processing failed: sufficient memory is not available.  
Explanation: At server installation, the server is unable to process the server  
database disks due to insufficient memory.  
System Action: Server installation stops.  
User Response: Restart the server installation process with more memory  
available.  
Tivoli Storage Manager Messages  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0267E  
ANR0268E  
ANR0269E  
Log volume volume name is not available.  
Explanation: The specified volume cannot be found during installation.  
System Action: Server installation stops.  
User Response: Determine the reason the disk is unavailable, and correct the  
problem. Restart the server installation process.  
Database volume volume name is not available.  
Explanation: The specified volume cannot be found during installation.  
System Action: Server installation stops.  
User Response: Determine the reason the disk is unavailable, and correct the  
problem. Restart the server.  
Process for Log volume volume name terminated - thread resource not  
available.  
Explanation: During installation for the indicated volume, the server cannot start a  
thread to service I/O requests.  
System Action: Server installation stops.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”. Restart the server installation process.  
ANR0270E  
Process for Database volume volume name terminated - thread resource not  
available.  
Explanation: During installation for the indicated volume, the server cannot start a  
thread to service I/O requests.  
System Action: Server installation stops.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”. Restart the server installation process.  
ANR0271E  
Maximum number of recovery log volumes exceeded.  
Explanation: More recovery log volumes have been specified than the server can  
manage.  
System Action: Server installation stops.  
32  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reduce the number of recovery log volumes specified. Restart the  
server installation process.  
ANR0272E  
Maximum number of database volumes exceeded.  
Explanation: More database volumes have been specified than the server can  
manage.  
System Action: Server installation stops.  
User Response: Reduce the number of database volumes specified. Restart the  
server installation process.  
ANR0285I  
Database page shadowing started using file file name.  
Explanation: The database page shadowing function was started. The file specified  
is used to store the shadowed database pages.  
System Action: None.  
User Response: None.  
ANR0286W  
Database page shadowing using file file name failed to start.  
Explanation: The database page shadowing function could not start. An error has  
been encountered accessing the page shadow file specified.  
System Action: None.  
User Response: Verify that there is enough space for the page shadow file. That  
page shadow file requires approximately 65 kilobytes of space, if this space is not  
available a new location for the file should be specified.  
ANR0287W  
Contents of the page shadow file file name are not valid.  
Explanation: The database page shadowing function could not use the contents of  
the existing file. Restart recovery using this file is not possible.  
System Action: The server attempts to start without having the database page  
shadow file available.  
User Response: The database page shadow file contents are not valid. This can be  
caused by: a partial write to the page shadow file itself, the file being manipulated  
by a process outside of the server, the file being overlayed by a different file, or the  
file could have been erased.  
Tivoli Storage Manager Messages  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0288W  
One or more database pages in the last batch written is corrupt - contents of  
database page shadow file will be used to fix the page or pages.  
Explanation: One or more pages from the last batch of pages written to the server  
database has been detected to be corrupt. The server will attempt to use the contents  
of database page shadow file and replace the corrupted database page.  
System Action: Server startup continues.  
User Response: A corruption of a database page within the server database, is  
typically caused by a partial write. A partial write may occur when the server is  
brought down external to normal server processing. If the server terminated without  
a halt command being issued or if the machine the server is running on crashed  
unexpectedly, this may account for the partial write. Other possible causes of a  
partial write are a disk drive failure, improperly terminated scsi bus, or a failure in a  
device controller. Please try to identify the cause of the partial write and take the  
appropriate action to prevent this from occurring in the future.  
ANR0289W  
ANR0290W  
ANR0291E  
Damaged database pages were successfully replaced using contents of page  
shadow file.  
Explanation: The damaged database pages were replaced using the corresponding  
pages from the page shadow file. The pages were successfully replaced.  
System Action: The server continues to restart.  
User Response: None.  
Failure occurred attempting to replace one or more damaged database pages  
using the contents of the page shadow file.  
Explanation: The damaged database pages could not be replaced using the  
corresponding pages from the page shadow file.  
System Action: The server continues to restart.  
User Response: None.  
Error writing to db page shadow file - restart will be attempted.  
Explanation: The server encountered an error writing to the database page shadow  
file. The page shadowing for the server is currently disabled.  
System Action: The server will attempt to restart the database page shadowing for  
the server once a minute until it is restarted or until the server is halted.  
User Response: Check the file specified as the database page shadow file. It may  
be that there is not enough space for the file. If enough space is available, check the  
filesystem, drive, or disk that it resides on for an indication of the error. Once the  
34  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
error preventing the server from writing to the page shadow file has been resolved,  
the server will recovery and begin writing to the page shadow file again.  
ANR0292W  
Database page shadow file file name does not exist.  
Explanation: The server attempted to use the page shadow file referenced but was  
unable to open the file. The file does not exist.  
System Action: The server will continue to operate and will attempt to create this  
as a new database page shadow file.  
User Response: None.  
ANR0300I  
ANR0301I  
Recovery log format started; assigned capacity count megabytes.  
Explanation: Initial formatting of the server recovery log has started.  
System Action: The log is formatted for use by the server.  
User Response: None.  
Recovery log format in progress; count megabytes of count.  
Explanation: The amount of the server recovery log shown has been successfully  
formatted.  
System Action: Formatting continues.  
User Response: None.  
ANR0302I  
Recovery log formatting took mseconds milliseconds.  
Explanation: Formatting of the recovery log has completed and took the number  
of milliseconds shown.  
System Action: None.  
User Response: None.  
ANR0303I  
Format rate: rate pages/second.  
Explanation: During formatting, the formatter processed the number of pages  
indicated each second.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0304I  
Page service time: rate ms.  
Explanation: During formatting, the formatter required the number of milliseconds  
indicated to process each page.  
System Action: None.  
User Response: None.  
ANR0305I  
ANR0306I  
ANR0307I  
Recovery log format complete.  
Explanation: Formatting of the server recovery log completed successfully.  
System Action: None.  
User Response: None.  
Recovery log volume mount in progress.  
Explanation: During restart, the server is mounting required recovery log volumes.  
System Action: None.  
User Response: None.  
Recovery log extend in progress; count megabytes of count formatted.  
Explanation: As a result of an EXTEND LOG command, the additional recovery  
log pages are being formatted.  
System Action: Formatting continues.  
User Response: None.  
ANR0309I  
Recovery log extend terminated - process canceled.  
Explanation: The process started as a result of an EXTEND LOG command and  
has been canceled.  
System Action: The EXTEND command is ended.  
User Response: None.  
ANR0311I  
Recovery log reduce in progress; count megabytes of count moved.  
Explanation: As a result of a REDUCE LOG command, the amount of data from  
the recovery log shown has been moved.  
System Action: The REDUCE LOG command continues.  
User Response: None.  
36  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0313I  
Recovery log reduce terminated - process canceled.  
Explanation: The process started as a result of a REDUCE LOG command and  
has been canceled.  
System Action: The REDUCE command is ended.  
User Response: None.  
ANR0314W  
Recovery log usage exceeds utilization percentage % of its assigned capacity.  
Explanation: This message is issued to notify the administrator that the server  
recovery log utilization exceeds 90% or more of its assigned capacity.  
System Action: Server operation continues.  
User Response:  
If the server is operating in NORMAL log mode, depending upon the size of  
your recovery log, add recovery log volumes, or extend the recovery log, or  
both, before it fills completely. Refer to the DEFINE LOGVOL, and EXTEND  
LOG commands for more information on these operations.  
If the server is operating in ROLLFORWARD log mode:  
v
v
v
backup the database, or  
define a database backup trigger if one is not already defined, or  
lower the database backup trigger if one is defined  
Refer to the DEFINE DBBACKUPTRIGGER or UPDATE  
DBBACKUPTRIGGER commands.  
ANR0350I  
Recovery checkpoint started.  
Explanation: During server initialization, the process of bringing the server  
database back to a state of consistency has begun.  
System Action: None.  
User Response: None.  
ANR0351I  
Recovery checkpoint complete.  
Explanation: During server initialization, the process of bringing the server  
database back to a state of consistency has completed successfully.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0352I  
ANR0353I  
ANR0354I  
ANR0355I  
ANR0356I  
ANR0357I  
Transaction recovery complete.  
Explanation: During server initialization, the process of recovering any incomplete  
transactions has completed successfully.  
System Action: None.  
User Response: None.  
Recovery log analysis pass in progress.  
Explanation: During server initialization, the process of analyzing the server  
recovery log has begun.  
System Action: None.  
User Response: None.  
Recovery log redo pass in progress.  
Explanation: During server initialization, the process of committing incomplete  
transactions has begun.  
System Action: None.  
User Response: None.  
Recovery log undo pass in progress.  
Explanation: During server initialization, the process of rolling back incomplete  
transactions has begun.  
System Action: None.  
User Response: None.  
Recovery log compression started.  
Explanation: The process of removing unneeded data from the server recovery log  
has begun.  
System Action: None.  
User Response: None.  
Recovery log compression ended.  
Explanation: The process of removing unneeded data from the server recovery log  
has completed.  
38  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR0358E  
ANR0359E  
ANR0360E  
Database initialization failed: sufficient memory is not available.  
Explanation: During server initialization, the server database fails initialization  
because sufficient server memory is not available.  
System Action: Initialization fails.  
User Response: Make more memory available to the server.  
Database initialization failed: unable to read database restart record.  
Explanation: During server initialization, the server database initialization fails  
because the required restart record cannot be read.  
System Action: Initialization fails.  
User Response: Contact your service representative.  
Database initialization failed: database size mismatch; LVM size = size,  
expected size = size.  
Explanation: During server initialization, the server database initialization fails  
because the size of the database does not match its prior size.  
System Action: Initialization fails.  
User Response: Contact your service representative.  
ANR0361E  
Database initialization failed: error initializing database page allocator.  
Explanation: During server initialization, the server database initialization fails  
because the page allocator cannot be started.  
System Action: Initialization fails.  
User Response: Contact your service representative.  
ANR0362W  
Database usage exceeds utilization percentage % of its assigned capacity.  
Explanation: This message is issued to notify the administrator that the server  
database utilization exceeds 80% or more of its assigned capacity.  
System Action: Server operation continues.  
User Response: Depending upon the size of your database, add database volumes,  
or extend the database, or both, before it fills completely. The server expiration  
Tivoli Storage Manager Messages  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
process may also free up database space making it available to other server  
processes. Refer to the EXPIRE INVENTORY, DEFINE DBVOL, and EXTEND  
DB commands for more information on these operations.  
ANR0363I  
Database was automatically upgraded to the server program level.  
Explanation: This message is issued to notify the administrator that the server  
database was automatically upgraded to the current server program level. The  
upgrade is performed when the UPGRADEDB parameter is specified at server  
start-up and the server is started over a database that was written by a down-level  
version of the server program.  
System Action: Server operation continues.  
User Response: None. The UPGRADEDB parameter does not need to be specified  
during future server start-ups.  
ANR0380W  
The database buffer pool recovered from an overcommit of number of pages  
pages. Consider increasing your buffer pool size by kilobytes needed kilobytes  
under current server load.  
Explanation: During normal processing, additional buffer pool space is required  
beyond that specified in the BUFPOOLSIZE in the server options file. The  
additional kilobytes of buffer pool space that are required are indicated in the  
message.  
System Action: Server operation continues; the additional buffer pool space is  
obtained from available server memory.  
User Response: If the current server load is typical, consider increasing the size  
specified for your BUFPOOLSIZE option by the number of kilobytes specified in  
the message. To do this, you must halt the server, change the options file, and then  
restart the server.  
ANR0381I  
Bufferpool statistics were successfully reset.  
Explanation: Bufferpool statistics, such as the Cache Hit Ratio, have been reset by  
the RESET BUFPOOL command.  
System Action: Server operation continues.  
User Response: The QUERY DB command (FORMAT=DETAILED) can be used  
to to display the current values for the buffer pool statistics.  
ANR0382I  
The database maximum utilization statistic was successfully reset.  
Explanation: The database maximum utilization statistic has been reset by the  
RESET DBMAXUTILIZATION command to the current utilization.  
40  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: The QUERY DB command (FORMAT=DETAILED) can be used  
to display the current value for the maximum utilization.  
ANR0383I  
ANR0384I  
ANR0385I  
The recovery log maximum utilization statistic was successfully reset.  
Explanation: The recovery log maximum utilization statistic has been reset by the  
RESET LOGMAXUTILIZATION command to the current utilization.  
System Action: Server operation continues.  
User Response: The QUERY LOG command (FORMAT=DETAILED) can be  
used to display the current value for the maximum utilization.  
The recovery log consumption statistic was successfully reset.  
Explanation: The recovery log consumption statistic has been reset by the RESET  
LOGCONSUMPTION command.  
System Action: Server operation continues.  
User Response: The QUERY LOG command (FORMAT=DETAILED) can be  
used to display the current value for recovery log consumption.  
Could not free sufficient buffers to reach reduced BUFPoolsize.  
Explanation: A reduction in the Data Base buffer pool size was requested.  
However, too many buffers were in use to reach the lower buffer pool size.  
System Action: Server operation continues. Whatever buffer pool size reduction  
that could be achieved is in effect. The new bufpoolsize is written to the options file  
for use on the next server startup.  
User Response: None.  
ANR0386I  
The BUFPoolsize has been changed to buffer pool size.  
Explanation: The BUFPoolsize option has been changed to the indicated value.  
System Action: Server operation continues.  
User Response: None.  
ANR0390W  
A server database deadlock situation has been encountered: lock request for  
transaction transaction ID will be denied to resolve the deadlock.  
Explanation: The server detected a deadlock situation between a number of  
processes attempting to access database information. A lock request for one of the  
Tivoli Storage Manager Messages  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
processes will be denied to resolve the database deadlock. When server processes  
encounter a database deadlock, they usually reattempt the function that was in  
progress when the deadlock was encountered. Not all process can explicitly re-try  
an operation. For example, migration and reclamation will eventually retry.  
However, something like a delete volume run in a macro will only retry if the delete  
command is reissued either in the macro or the command line.  
System Action: A lock request fails for one of the deadlocked processes. Server  
operation continues.  
User Response: If a process can retry (like migration), then monitor the re-try  
attempt to see if it succeeds or not. If it fails, contact a service representative. If the  
process or command is not able to retry on it’s own, then reissue the command or  
macro that caused the action to occur. If it fails again, contact a service  
representative for further assistance to better isolate the deadlock condition.  
ANR0400I  
ANR0401I  
ANR0402I  
Session session number started for node node name (client platform)  
(communication method).  
Explanation: A new client session has been initiated by the specified node. The  
session number, client platform type and communication method used by this  
session are included in the message.  
System Action: The server begins a communications session to service the client  
node.  
User Response: None.  
Session session number started for node node name (client platform)  
(communication method) (WDSF client).  
Explanation: A new WDSF client session has been initiated by the specified node.  
The session number, client platform type and communication method used by this  
session are included in the message.  
System Action: The server begins a communications session to service the client  
node.  
User Response: None.  
Session session number started for administrator administrator ID  
(administrators platform) (communication method).  
Explanation: A new administrator client session has been initiated by the specified  
administrator. The session number, administrator’s platform type and communication  
method used by this session are included in the message.  
System Action: The server begins a communications session to service the  
administrator client.  
42  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR0403I  
ANR0404I  
Session session number ended for node node name (client platform).  
Explanation: A client session has completed normally.  
System Action: Server operation continues.  
User Response: None.  
Session session number ended for node node name (client platform) (WDSF  
client).  
Explanation: A WDSF client session has completed normally.  
System Action: Server operation continues.  
User Response: None.  
ANR0405I  
Session session number ended for administrator administrator ID (client  
platform).  
Explanation: An administrative client session has completed normally.  
System Action: Server operation continues.  
User Response: None.  
ANR0406I  
Session session number started for node node name (client platform)  
(communication method communication address).  
Explanation: A new client session has been initiated by the specified node. The  
session number, client platform type, communication method and address used by  
this session are included in the message.  
System Action: The server begins a communications session to service the client  
node.  
User Response: None.  
ANR0407I  
Session session number started for administrator administrator ID  
(administrators platform) (communication method communication address).  
Explanation: A new administrator client session has been initiated by the specified  
administrator. The session number, administrator’s platform type, communication  
method and address used by this session are included in the message.  
System Action: The server begins a communications session to service the  
administrator client.  
Tivoli Storage Manager Messages  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR0408I  
Session session number started for server server name (servers platform)  
(communication method) for purpose.  
Explanation: A new server session has been initiated by the specified server for  
the specified purpose. The session number, server’s platform type and  
communication method used by this session are included in the message.  
System Action: The server begins a communications session to service the  
administrator client.  
User Response: None.  
ANR0409I  
Session session number ended for server server name (client platform).  
Explanation: A server has completed normally.  
System Action: Server operation continues.  
User Response: None.  
ANR0418W  
Session session number for administrator administrator name (client platform)  
refused - invalid password submitted.  
Explanation: The server refuses a request to start a client session because an  
invalid password has been submitted by the client during sign-on processing. The  
server will continue to deny access attempts by this client until a valid password is  
submitted.  
System Action: Server operation continues.  
User Response: Enter the proper password. If the password has been forgotten by  
the user, an authorized administrator can assign a new password by using the  
UPDATE ADMIN command.  
ANR0419W  
Administrative client userid administrative ID cannot be used when  
authentication is on.  
Explanation: The server refuses a request for a client (administrative) session  
because the user ID specified cannot be used when authentication of IDs is in effect.  
SERVER_CONSOLE is an administrative ID that has this restriction.  
System Action: Server operation continues.  
User Response: Use an administrative ID that was registered for this server and  
that has a password.  
44  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0420W  
Session session number for node node name (client platform) refused - server  
disabled for user access.  
Explanation: The server refuses a request for a client (backup-archive) session  
because the server is currently disabled for client access.  
System Action: Server operation continues. Administrative clients are permitted  
access to the server.  
User Response: An authorized administrator must issue the ENABLE command  
before client nodes are permitted access to the server.  
ANR0421W  
Session session number for node node name (client platform) refused - sign-on  
protocol violation.  
Explanation: The server refuses a request for a client session because sign-on  
protocol has been violated.  
System Action: Server operation continues.  
User Response: This error is usually the result of a client programming error in  
which the sign-on verb has been incorrectly formatted and delivered to the server.  
This error can also result when the server is contacted by an application that is not a  
part of this product.  
ANR0422W  
Session session number for node node name (client platform) refused - node name  
not registered.  
Explanation: The server refuses a request to start a client session because the  
client node name is not registered in the server database.  
System Action: Server operation continues.  
User Response: Register the node name with the server before establishing a  
session. If the server is running with OPEN registration, no action is required; the  
client prompts the user for a password and registers the client with the server. If  
CLOSED registration is in effect on the server, an authorized administrator must use  
the REGISTER NODE command to register the client node name with the server.  
ANR0423W  
Session session number for administrator administrator ID (client platform)  
refused - administrator name not registered.  
Explanation: The server refuses a request to start an administrative session  
because the administrator name is not registered in the server database.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Register the administrator name with the server before  
establishing a session. An authorized administrator must use the REGISTER  
ADMIN command to register the administrator with the server.  
ANR0424W  
Session session number for node node name (client platform) refused - invalid  
password submitted.  
Explanation: The server refuses a request to start a client session because an  
invalid password has been submitted by the client during sign-on processing. The  
server will continue to deny access attempts by this client until a valid password is  
submitted.  
System Action: Server operation continues.  
User Response: Enter the proper password. If the password has been forgotten by  
the user, an authorized administrator can assign a new password by using the  
UPDATE NODE command.  
ANR0425W  
Session session number for node node name (client platform) refused - password  
has expired.  
Explanation: The server refuses the specified session because the administrator or  
client node’s password has expired.  
System Action: Server operation continues.  
User Response: Upon receipt of this error condition, the client program  
immediately reconnects to the server specifying a password update session and  
prompts the user for a new password. After the user enters a new password, the  
client reconnects to the server for normal operations. Alternatively, an authorized  
administrator can update the client password using the UPDATE NODE or  
UPDATE ADMIN command.  
ANR0426W  
Session session number for node node name (client platform) refused - open  
registration not permitted.  
Explanation: The server refuses a client session because an open registration  
action has been attempted and the server is running with CLOSED registration.  
System Action: Server operation continues.  
User Response: Ask an authorized administrator to submit the request using the  
REGISTER NODE or REGISTER ADMIN command.  
46  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0427W  
Session session number for node node name (client platform) refused - server  
version is down-level with this client.  
Explanation: The server refuses a client session because the client program  
version level is newer than that supported by the server program.  
System Action: Server operation continues.  
User Response: Apply service to the server program to make it compatible with  
the newer client program, or use an older client program to contact the server.  
ANR0428W  
Session session number for node node name (client platform) refused - client is  
down-level with this server version.  
Explanation: The server refuses a client session because the client program  
version level is older than that supported by the server program. For certain  
problems (such as the compression fix), once a node connects to the server using  
the newer client, the server records this fact and will not let this node back off this  
client version to a version that does not include the fix.  
System Action: Server operation continues.  
User Response: Apply service to the client program to make it compatible with  
the newer server program.  
ANR0429W  
Session session number for node node name (client platform) refused - maximum  
server sessions (max sessions allowed) exceeded.  
Explanation: The server refuses the specified client or administrative session  
because the maximum number of concurrent client sessions has been exceeded.  
System Action: Server operation continues.  
User Response: If necessary, increase the maximum number of permitted sessions.  
To do this, update the value for the MAXSESSIONS parameter in the server options  
file and restart the server with the updated options file. Note that increasing the  
MAXSESSIONS value requires additional memory resource by the server. You may  
want to retry the connection at a later time.  
ANR0430W  
Session session number for node node name (client platform) refused - node name  
is locked.  
Explanation: The server refuses the specified client session because the node is  
locked from server access (with the LOCK NODE command).  
System Action: Server operation continues.  
User Response: Before the client node is permitted to access the server, a properly  
authorized administrator must unlock the node with the UNLOCK NODE command.  
Tivoli Storage Manager Messages  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0431W  
ANR0432W  
ANR0433W  
ANR0434W  
Session session number refused - administrator administrator ID (client platform)  
is locked.  
Explanation: The server refuses the specified administrative session because the  
administrator is locked from server access (with the LOCK ADMIN command).  
System Action: Server operation continues.  
User Response: Before the administrator is permitted to access the server, a  
properly authorized administrator must unlock the administrator with the UNLOCK  
ADMIN command.  
Session session number for node node name (client platform) refused - insufficient  
memory.  
Explanation: The server ends the specified session because sufficient memory  
(virtual memory) is not available.  
System Action: The server ends the session and continues operation.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
Session session number for node or administrator ID (client platform) refused -  
insufficient recovery log space.  
Explanation: The server ends the specified client or administrative session because  
sufficient log space is not available to complete a database transaction.  
System Action: The server ends the session and continues operation.  
User Response: To increase the amount of log space available to the server, an  
authorized administrator can add log volumes using the DEFINE LOGVOLUME  
command, and extend the size of the log using the EXTEND LOG command.  
Session session number for node or administrator ID (client platform) refused -  
insufficient database space.  
Explanation: The server ends the specified client or administrative session because  
sufficient database space is not available to complete a database transaction.  
System Action: The server ends the session and continues operation.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes using the DEFINE  
DBVOLUME command, and extend the size of the database using the EXTEND  
DB command.  
48  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0435W  
Session session number for node node name (client platform) refused - internal  
error detected.  
Explanation: The server ends the specified session because an internal logic error  
is detected.  
System Action: The server ends the session and continues operation.  
User Response: To determine the source of the error, the administrator can  
examine server messages issued prior to this message. The QUERY ACTLOG  
command can be used to view the activity log and search for messages. If the error  
cannot be isolated and resolved, contact your service representative.  
ANR0436W  
Session session number refused - a WDSF client is attempting to access the  
server using client name client node name (client platform), associated with a  
non-WDSF client.  
Explanation: The server refuses a client session because a Workstation DataSave  
Facility (WDSF) client is attempting to access the server using a node name  
associated with a non-WDSF client. When converting from WDSF, WDSF client  
programs cannot be used to access the server with a specific node name once the  
non-WDSF client program has been used to access the server with that node name.  
System Action: Server operation continues.  
User Response: Access the server using a non-WDSF client program for the node  
name.  
ANR0437W  
Session session number for node client node name (client platform) encountered  
an internal server error while checking license compliance.  
Explanation: The server encountered an internal error in determining if the server  
is in compliance with license terms.  
System Action: The client session is ended.  
User Response: Use the QUERY LICENSE and QUERY STATUS commands to  
determine if the server is in compliance with license terms. Start an AUDIT  
LICENSES process to re-adjust server license information. When this process  
completes you may restart the session. If the problem persists, contact your service  
representative.  
ANR0438W  
Session session number archive operation for client client node name (client  
platform) has been denied - Server is not in compliance with license terms.  
Explanation: The server refuses a client archive operation because the current  
server configuration is not in compliance with license terms.  
Tivoli Storage Manager Messages  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. Clients may perform any action except  
backup or archive.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance.  
ANR0439W  
Session session number backup operation for client client node name (client  
platform) has been denied - Server is not in compliance with license terms.  
Explanation: The server refuses a client backup operation because the current  
server configuration is not in compliance with license terms.  
System Action: Server operation continues. Clients may perform any action except  
backup or archive.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance.  
ANR0440W  
Protocol error on session session number for node client node name (client  
platform) - invalid verb header received.  
Explanation: The server detects a protocol error on the specified session because  
an invalid verb header has been received from the client. Verb headers always  
precede communication sent to the server from the client or from the server to the  
client.  
System Action: The server ends the client session.  
User Response: Correct the programming error in the client program if it has been  
written by your installation using WDSF verbs. Otherwise, contact your service  
representative.  
ANR0441W  
Protocol error on session session number for node client node name (client  
platform) - invalid data length received.  
Explanation: The server detects a protocol error on the specified session because  
an invalid verb length has been received from the client.  
System Action: The server ends the client session.  
User Response: Correct the programming error in the client program if it has been  
written by your installation using WDSF verbs. Otherwise, contact your service  
representative.  
ANR0442W  
Protocol error on session session number for node client node name (client  
platform) - excessively large verb received.  
Explanation: The server detects a protocol error on the specified session because  
an invalid verb length has been received from the client.  
50  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server ends the client session.  
User Response: Correct the programming error in the client program if it has been  
written by your installation using WDSF verbs. Otherwise, contact your service  
representative.  
ANR0443W  
ANR0444W  
ANR0445W  
Protocol error on session session number for node client node name (client  
platform) - invalid field namefield found in verb nameverb (offset offset  
position).  
Explanation: The server detects a protocol error on the specified session because  
an invalid field has been found in a verb sent from the client node.  
System Action: The server ends the client session.  
User Response: Correct the programming error in the client program if it has been  
written by your installation using WDSF verbs. Otherwise, contact your service  
representative.  
Protocol error on session session number for node client node name (client  
platform) - out-of-sequence verb (type verb name) received.  
Explanation: The server detects a protocol error on the specified session because a  
verb has been received that does not adhere to the client-server exchange sequence.  
System Action: The server ends the client session.  
User Response: If the client generating the error is not an API client, contact your  
service representative. If the client generating the error is an API client, contact the  
owner of the API client. If the client generating the error is a client that you have  
created using WDSF verbs, correct the programming error in your client program.  
Protocol error on session session number for node client node name (client  
platform) - maximum group transaction size exceeded.  
Explanation: The server detects a protocol error on the specified session because  
the client has attempted to group more than the maximum database update  
operations in a single database transaction.  
System Action: The server ends the client session.  
User Response: Correct the programming error in the client program if it has been  
written by your installation using WDSF verbs. Otherwise, contact your service  
representative.  
Tivoli Storage Manager Messages  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0446W  
ANR0447W  
ANR0448W  
ANR0449W  
Session session number client client node name compression method unsupported  
- Compression forced OFF. Please obtain the latest level of the client code.  
Explanation: The client is using a compression method that is no longer supported  
by the Server.  
System Action: Server operation continues. The client’s backup operation  
continues, without compressing the data.  
User Response: The compression method used by the client is no longer  
supported. In order to use compression, the client needs to be upgraded to a client  
service level that supports the newer compression method.  
Session session number space management migration operation for client client  
node name (client platform) has been denied - Server is not in compliance with  
license terms.  
Explanation: The server refuses a client space management migration operation  
because the current server configuration is not in compliance with license terms.  
System Action: Server operation continues. Clients may perform any action except  
backup, archive, or space-managed file migration.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance.  
Session session number space management migration operation for client client  
node name (client platform) has been denied - server is not licensed for space  
management support.  
Explanation: The server refuses a client space management migration operation  
because the server is not licensed to support space-managed clients.  
System Action: Server operation continues.  
User Response: Licenses to support space-managed clients can be obtained from  
your service provider or reseller. The REGISTER LICENSE command can be used  
with these licenses to enable space management support.  
Session session number space management migration operation for client client  
node name (client platform) is in violation of server license terms - server is not  
licensed for space management support.  
Explanation: The server warns about a client space management migration  
operation because the server is not licensed to support space-managed clients.  
System Action: Server operation continues.  
52  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Licenses to support space-managed clients can be obtained from  
your service provider or reseller. The REGISTER LICENSE command can be used  
with these licenses to enable space management support.  
ANR0450W  
Session session number for server server name (client platform) refused - server  
name not defined for server to server communications.  
Explanation: The server refuses a request to start a server session because the  
requesting server name is not defined in the server database, or the requesting server  
definition does not have a SERVERPASSWORD.  
System Action: Server operation continues.  
User Response: Register the requesting server name with the server before  
establishing a session, or update the existing requesting server definition and set a  
SERVERPASSWORD. An authorized administrator must use the DEFINE SERVER  
or UPDATE SERVER command to register the requesting server and set the  
password.  
ANR0451W  
Session session number for server server name (server platform) refused - invalid  
password submitted.  
Explanation: The server refuses a request to start a server session because an  
invalid password has been submitted during sign-on processing. The server will  
continue to deny access attempts by that server until valid passwords are submitted.  
System Action: Server operation continues.  
User Response: Set the proper passwords. If the password has been changed on  
either server, an authorized administrator can set new passwords by using the  
UPDATE SERVER command with the SERVERPASSWORD parameter.  
ANR0452W  
Session for server server name refused - server name not defined for server to  
server communications.  
Explanation: The server refuses a request to start a server to server session  
because a server name is not defined in the server database, or the server definition  
does not have a SERVERPASSWORD. Server to server communications using the  
serverpassword requires that the each server has had a server definition for the other  
server.  
System Action: Server operation continues.  
User Response: Register the server names on both both servers before establishing  
a session, or update the server’s existing server definition and set a  
SERVERPASSWORD. An authorized administrator must use the DEFINE SERVER  
or UPDATE SERVER command register the servers and set the passwords.  
Tivoli Storage Manager Messages  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0453W  
Server to server session refused - no password defined.  
Explanation: The server to server session cannot be initiated because no server  
password has been defined for this server.  
System Action: Server operation continues.  
User Response: Define a server password with the SET SERVERPASSWORD  
command and retry the command.  
ANR0454E  
Session rejected by server server name, reason: rejection reason.  
Explanation: The server has attempted to open a session with the shown server.  
The session was rejected for the indicated reason.  
System Action: The operation fails.  
User Response: Check both the servers for any additional messages that might  
further describe the reason the session was rejected. For a reason of  
AUTHENTICATION FAILURE, ensure that all passwords have been set correctly  
on both servers. The password for the server (set by SET SERVERPASSWORD on  
server X) and the password in the server definition (set by DEFINE or UPDATE  
SERVER X SERVERPASSWORD=) are the same password. For a reason of  
VERIFICATION FAILURE, use the QUERY SERVER command to determine that  
the HLADDRESS and LLADDRESS of the target server are correct. If they are not,  
correct them with the UPDATE SERVER command. If they are correct,  
resyncronize with the target server by issuing the UPDATE SERVER  
FORCESYNC=YES. For a reason of COMMUNICATION FAILURE ensure that  
the target server is available and that TCPIP is available on both servers. For a  
reason of NO RESOURCE, ensure that the receiving server is enabled, has  
sufficient DB, LOG, and memory resource to support the source server session. For  
a reason of INTERNAL ERROR, use the messages on the target server to determine  
the problem and contact your service representative. Retry the failing operation.  
ANR0455W  
Invalid Command command name for SNMP session.  
Explanation: An SNMP administrative session attempted to run a command which  
is not an macro invocation. SNMP administrative sessions are only allowed to issue  
macro commands.  
System Action: The server ends the client session.  
User Response: Enter commands through the SNMP administrative interface  
which are macros defined on the server.  
54  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0456W  
ANR0457W  
ANR0459W  
Session rejected for server name server name at High level address Low level  
address does not match.  
Explanation: The server name at the address specified does not match the name in  
the server definition. The connection is not established.  
System Action: The server continues.  
User Response: Insure the HLADDRESS and LLADDRESS in the define server  
command are correct, and that the servername on the server being contacted  
matches the name used in the DEFINE SERVER command.  
Session for server server name refused - crossdefine is not allowed on this  
server.  
Explanation: The server refuses a request to start a server to server session for  
crossdefine because it is not allowed on this server. The server will deny any  
sessions for crossdefine until crossdefine is allowed on this server.  
System Action: Server operation continues.  
User Response: An authorized administrator must use the SET CROSSDEFINE  
ON command to allow cross registration of servers.  
Signon for administrator administrator name refused - invalid administrator  
name and/or password submitted.  
Explanation: The server refuses a request to start an administrative session  
because an invalid administrator name and/or password has been submitted by the  
user during sign-on processing. The server will continue to deny access attempts by  
this administrator until a valid password is submitted, or until the administrator is  
locked due to maximum number of invalid password attempts being exceeded.  
System Action: Server operation continues.  
User Response: Enter the proper password. If the password has been forgotten by  
the user, an authorized administrator can assign a new password by using the  
UPDATE ADMIN command.  
ANR0460W  
Open registration failed for session session number - node name node name  
(client platform) already exists.  
Explanation: The server refuses a client session during open registration because  
the client has specified a node name that is already registered on the server.  
System Action: Server operation continues.  
User Response: The client program user must specify a different node name for  
the client in the client options file.  
Tivoli Storage Manager Messages  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0461W  
Open registration failed for session session number for node node name (client  
platform) - policy domain STANDARD does not exist.  
Explanation: The server refuses a client session during open registration because  
the STANDARD policy domain does not exist. All nodes added to the server  
database under open registration are automatically assigned to the STANDARD  
policy domain. This policy domain must be defined and have an active policy set to  
support open registration.  
System Action: Server operation continues.  
User Response: If you want to support open registration, define a policy domain  
using the DEFINE DOMAIN command with the name STANDARD and activate a  
valid policy set in the domain. You can issue the UPDATE NODE command to  
move nodes to different policy domains after the nodes have registered themselves  
through open registration.  
ANR0462W  
ANR0463W  
ANR0464W  
Open registration failed for session session number for node node name (client  
platform) - invalid node name.  
Explanation: The server refuses a client session during open registration because  
the node name specified by the client is not valid.  
System Action: Server operation continues.  
User Response: Specify a node name in the options file of the client program that  
contains valid characters and does not exceed the maximum length in size. Refer to  
Using the Backup-Archive Client for a description of the node name restrictions.  
Open registration failed for session session number for node node name (client  
platform) - invalid password.  
Explanation: The server refuses a client session during open registration because  
the password name specified by the user is not valid.  
System Action: Server operation continues.  
User Response: Specify a password that uses valid characters and is less than the  
maximum length in size. Refer to Using the Backup-Archive Client for a description  
of the password restrictions.  
Open registration failed for session session number for node node name (client  
platform) - exceeded number of nodes available under license terms.  
Explanation: The server detected an attempt to register more nodes than allowed  
by the terms of the current license.  
System Action: Server operation continues, but the REGISTER NODE command  
fails, and the node is not registered.  
56  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance.  
ANR0465W  
Open registration failed for session session number for node node name (client  
platform) - policy domain STANDARD does not have an ACTIVE policy set.  
Explanation: The server refuses a client session during open registration because  
the STANDARD policy domain does not have an active policy set. All nodes added  
to the server database under open registration are automatically assigned to the  
STANDARD policy domain. This policy domain must be defined and have an  
active policy set to support open registration.  
System Action: Server operation continues.  
User Response: If you want to support open registration, define a policy domain  
using the DEFINE DOMAIN command with the name STANDARD and activate a  
valid policy set in the domain. You can issue the UPDATE NODE command to  
move nodes to different policy domains after the nodes have registered themselves  
through open registration.  
ANR0479W  
Session session number for server server name (server platform) terminated -  
connection with server severed.  
Explanation: If server A has opened a connection with server B, server B’s  
session is ended because the communications link has been closed by a network  
error or by server A’s program.  
System Action: Server A continues operation.  
User Response: If server B halts operation or in some way stops communicating  
with server A, this message will be displayed on server A indicating that the  
connection was closed suddenly by server B. A network failure can also cause this  
message to be displayed. If a large number of these messages occur simultaneously,  
check the network for failure and correct any problems.  
ANR0480W  
Session session number for node node name (client platform) terminated -  
connection with client severed.  
Explanation: The specified client session is ended because the communications  
link has been closed by a network error or by the client program.  
System Action: Server operation continues.  
User Response: If a user breaks out of a client program, this message will be  
displayed on the server as the connection is suddenly closed by the client. A  
network failure can also cause this message to be displayed. If a large number of  
these messages occur simultaneously, check the network for failure and correct any  
problems.  
Tivoli Storage Manager Messages  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0481W  
Session session number for node node name (client platform) terminated - client  
did not respond within commtimeout seconds seconds.  
Explanation: The server ends a client session because the client has been holding  
database locks (a transaction was in progress) and the client has not responded in  
the number of seconds specified by the COMMTIMEOUT parameter in the server  
options file.  
System Action: The server rolls back the transaction that has been in progress and  
the session is ended. Server operation continues.  
User Response: If a large number of these messages appear, you may want to  
increment the value specified for the COMMTIMEOUT value in the server options  
file and restart the server. The amount of time that it takes for a client to respond is  
dependent upon the speed and processor load for the client and the network load.  
ANR0482W  
Session session number for node node name (client platform) terminated - idle for  
more than idletimeout minutes minutes.  
Explanation: The server ends a client session because it has been idle for more  
minutes than specified in the IDLETIMEOUT parameter in the server options file.  
The client program will automatically attempt to reconnect to the server when  
necessary.  
System Action: Server operation continues.  
User Response: If the problems persists, increase the value specified for the  
IDLETIMEOUT parameter in the server options file and restart the server. Many  
times, the client program is idle while waiting for the user to choose an action to  
perform (for example, backup, archive, restore, or retrieve files). If a user starts the  
client program and does not choose an action to perform, the session will eventually  
time out. The client program automatically reconnects to the server when the user  
chooses an action that requires server participation. Note that a large number of idle  
sessions can inadvertently prevent other users from connecting to the server, so care  
should be used when increasing the IDLETIMEOUT parameter.  
ANR0483W  
Session session number for node node name (client platform) terminated - forced  
by administrator.  
Explanation: The server ends a client session in response to a CANCEL  
SESSION command issued by an authorized administrator.  
System Action: The server rolls back any transactions in progress for the  
terminated client session.  
User Response: None.  
58  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0484W  
Session session number for node node name (client platform) terminated -  
protocol violation detected.  
Explanation: The server ends the specified session because a communications  
protocol error by the client has been detected.  
System Action: The server ends the client session.  
User Response: Examine the client message to determine the problem. Correct the  
programming error in the client program. If the error cannot be isolated and  
resolved, contact your service representative.  
ANR0485W  
Session session number for node node name (client platform) terminated -  
sufficient memory is not available.  
Explanation: The server ends the specified session because sufficient memory  
(virtual memory) is not available.  
System Action: The server ends the session and continues operation.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0486W  
Session session number for node node name (client platform) terminated -  
internal error detected.  
Explanation: The specified client session is ended by the server because an  
internal processing error has been detected on the server. A programming error may  
have occurred in the server program.  
System Action: The session is ended and server operation continues.  
User Response: Contact your service representative.  
ANR0487W  
Session session number for node node name (client platform) terminated -  
preempted by another operation.  
Explanation: The server ends a client session in response to a cancel request  
issued by a higher priority operation that needed the mount point that the client was  
using.  
System Action: The server rolls back any transactions in progress for the  
terminated client session.  
User Response: Reissue the operation. If this message appears frequently, consider  
increasing the mountlimit value for the affected device class.  
Tivoli Storage Manager Messages  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0488W  
Session session number for node node name (client platform) terminated -  
transfer rate is less than (transfer rate) and more than (elapsed time since first  
data transfer) minutes have elapsed since first data transfer.  
Explanation: The server is canceling client session number session number.  
Depending on the state of the session, it may take a while for the session to be  
canceled. The server ends a client session because it has been active for more  
minutes than specified in the THROUGHPUTTIMETHRESHOLD parameter in the  
server options file and the data transfer rate is less than the amount sepcified with  
the THROUGHPUTDATATHRESHOLD parameter in the server options file. The  
client is transferring data to the server at an abnormally slow rate and may have  
become a bottleneck for handling data from other clients. If the client has caused  
log records to be written, it is possible that this client will prevent log space  
reclamation.  
System Action: The session is canceled and server operation continues.  
User Response: If a low data transfer rate is not a problem, the  
THROUGHPUTTIMETHRESHOLD or THROUGHPUTDATATHRESHOLD  
parameters in the server options file can be set to zero - this will disable the  
throughput check. The change can be made without taking down the server and  
restarting it by using the SETOPT THROUGHPUTTIMETHRESHOLD or the  
SETOPT THROUGHPUTDATATHRESHOLD commands. If a low data transfer rate  
is not expected, external causes should be investigated. This would include network  
problems and problems in accessing data on the client node. The client program  
may automatically reconnect to the server, so this message may appear on  
susbsequent sessions until the data transfer problem is resolved. The default server  
operation is not to perform a throughput check.  
ANR0490I  
Canceling session session number for node node name (client platform) .  
Explanation: The server is canceling client session number session number. This  
message is displayed in response to the CANCEL SESSION command. Depending  
on the state of the session, it may take a while for the session to be canceled.  
System Action: The session is canceled and server operation continues.  
User Response: None.  
ANR0491I  
No matching session(s) found to cancel.  
Explanation: The server cannot find any sessions to cancel matching the  
specifications entered in the CANCEL SESSION command.  
System Action: Server operation continues.  
60  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the QUERY SESSION command to ensure that the session  
you wish to cancel is connected. Reissue the command using the appropriate session  
number to cancel the client session.  
ANR0492I  
All drives in use. Session session number for node node name (client platform)  
being preempted by higher priority operation.  
Explanation: When a high priority operation attempted to find an available drive,  
all the drives were being used. To free up a drive for this operation, the client  
session identified is being cancelled by the system.  
System Action: The lower priority client session is cancelled to free up a mount  
point (drive).  
User Response: When a drive again becomes available, restart the session that was  
cancelled. This session was most likely a backup/archive session and you may just  
want to let it restart automatically during its next scheduled backup window. If this  
message appears frequently, you may want to increase the number of drives  
available. See the MOUNTLIMIT parameter on the UPDATE DEVCLASS  
command.  
ANR0493I  
Restore session session number canceled.  
Explanation: The specified session was canceled with the CANCEL RESTORE  
command.  
System Action: The restore session is canceled and server operation continues.  
User Response: None.  
ANR0494I  
Volume volume name in use. Session session number for node node name (client  
platform) being preempted by higher priority operation.  
Explanation: When a high priority operation attempted to acquire a specific  
volume, it was being used. To free the volume for this operation, the client session  
identified is being cancelled by the system.  
System Action: The lower priority client session is cancelled to free up the  
volume.  
User Response: Restart the session that was cancelled, it will wait until the higher  
priority operation if finished with the volume. This cancelled session was most  
likely a backup/archive session and you may just want to let it restart automatically  
during its next scheduled backup window.  
Tivoli Storage Manager Messages  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0500W  
ANR0501W  
ANR0520W  
Transaction failed for session session number for node node name (client  
platform) - invalid password submitted.  
Explanation: The server ends a password update transaction because the user has  
not correctly specified the current password.  
System Action: Server operation continues.  
User Response: Update your password by correctly specifying the current  
password. If the current password has been misplaced, the administrator can  
reassign a password for the client by using the UPDATE NODE or UPDATE  
ADMIN command.  
Transaction failed for session session number for node node name (client  
platform) - invalid policy binding specified.  
Explanation: The server ends a database update transaction for the specified  
session because an invalid management class has been specified for a file or  
directory object.  
System Action: The specified session is ended and server operation continues.  
User Response: Correct the programming error in the client program if it has been  
written by your installation using WDSF verbs. Otherwise, contact your service  
representative.  
Transaction failed for session session number for node node name (client  
platform) - storage pool pool name is not defined.  
Explanation: The server rolls back a database update transaction for the specified  
session because the destination specified for a management class copy group  
specifies the named storage pool, but that storage pool does not exist.  
System Action: Server operation continues.  
User Response: An administrator with policy authority over the client policy  
domain must correct management class definitions so that copy group destinations  
refer to defined storage pools, or the specified storage pool must be created by an  
authorized administrator.  
ANR0521W  
Transaction failed for session session number for node node name (client  
platform) - object excluded by size in storage pool pool name and all successor  
pools.  
Explanation: The server ends a database update transaction for the specified  
session because the size of a file sent from the client node is larger than that  
62  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
allowed in the storage pool specified in the client’s management class copy group.  
No successor storage pools to the one specified on the copy group can accept the  
large file.  
System Action: The specified session is ended and server operation continues.  
User Response: If the client is not using compression to send files to the host,  
turn compression on for the client (using the UPDATE NODE command) to try and  
resolve the problem. Otherwise, the maximum file size for one or more of the  
storage pools in the storage hierarchy can be increased to accommodate the file. An  
authorized administrator can increase the MAXSIZE parameter by issuing the  
UPDATE STGPOOL command.  
ANR0522W  
Transaction failed for session session number for node node name (client  
platform) - no space available in storage pool pool name and all successor pools.  
Explanation: The server ends a database update transaction for the specified  
session because the storage pool specified in the client’s management class copy  
group does not contain enough free space to hold the files sent from the client.  
Successor storage pools to the one specified on the copy group do not contain  
enough free space.  
System Action: The specified session is ended and server operation continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy. This  
action may also involve creating storage space by using an operating system specific  
utility.  
ANR0523W  
Transaction failed for session session number for node node name (client  
platform) - error on output storage device.  
Explanation: The server ends a database update transaction for the specified client  
because an I/O error has been encountered by the server in writing to a device.  
System Action: The specified session is ended and server operation continues.  
User Response: Query the activity log to find messages preceding this one that  
specify the failing device. Storage pool volumes can be varied offline (by using the  
VARY command), or the server may need to be halted to correct the hardware  
problem. After the problem is corrected, the client should retry the operation.  
ANR0524W  
Transaction failed for session session number for node node name (client  
platform) - data transfer interrupted.  
Explanation: The database transaction associated with session session number was  
aborted because data transfer to or from data storage was interrupted by an external  
event.  
Tivoli Storage Manager Messages  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The session is canceled and server operation continues.  
User Response: Examine the messages issued prior to this message to determine  
why the data transfer was interrupted. Attempt the client operation again if the  
problem can be resolved.  
ANR0525W  
Transaction failed for session session number for node node name (client  
platform) - storage media inaccessible.  
Explanation: The server ends a transaction for the specified session because  
storage volumes are not available in the storage pools in which the client’s files are  
to be stored.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy. The  
VARY ONLINE command can be used to vary offline storage volumes online in the  
storage hierarchy to make them available to client nodes for file storage.  
ANR0526W  
Transaction failed for session session number for node node name (client  
platform) - sufficient recovery log space is not available.  
Explanation: The server ends a database update transaction for the specified  
session because sufficient log space is not available on the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log, and can issue the  
EXTEND LOG command to extend the size of the log so that the new volumes are  
used.  
ANR0527W  
Transaction failed for session session number for node node name (client  
platform) - sufficient database space is not available.  
Explanation: The server ends a database update transaction for the specified  
session because sufficient database space is not available on the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: An authorized administrator can issue the DEFINE DBVOLUME  
command to add volumes for use by the database, and can issue the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
64  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0528W  
Transaction failed for session session number for node node name (client  
platform) - thread resource not available.  
Explanation: The server ends a database update transaction for the specified  
session because sufficient memory is not available for starting additional processes  
on the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0529W  
Transaction failed for session session number for node node name (client  
platform) - insufficient memory.  
Explanation: The server ends a database update transaction for the specified  
session because sufficient memory is not available on the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0530W  
Transaction failed for session session number for node node name (client  
platform) - internal server error detected.  
Explanation: The server ends a database update transaction for the specified  
session because an internal logic error is detected.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0531W  
Transaction failed for session session number for node node name (client  
platform) - invalid file space identifier specified by client.  
Explanation: The server ends a database update transaction for the specified  
session because the file space identified by the client for the transaction does not  
exist.  
Tivoli Storage Manager Messages  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: This action usually occurs when a client is operating on a file  
space that is currently being deleted as a result of an administrative command or  
client action. The server ends the specified session and server operation continues.  
User Response: Use the QUERY PROCESS command to monitor and wait for  
any file space deletion processes to complete, or cancel the process if you do not  
want to delete the file space. Try the client action again after this action has been  
taken.  
ANR0532W  
DiagnosticID: Transaction transaction ID was aborted for session session number  
for node node name (client platform).  
Explanation: An error has been detected during a transaction commit for the  
specified session. This message should be preceded by other messages that give  
additional information about the failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
ANR0533W  
Transaction failed for session session number - compression method used by  
client not supported. Please obtain the latest level of the client code.  
Explanation: The server ends the transaction for the specified session because the  
compression method that is used by the client is no longer supported by the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: The client must either backup the data with compression turned  
off, or upgrade to a client that supports the newer compression method. If the client  
is a WDSF client, upgrade to a non-WDSF client in order to use the compression  
performed by the client.  
ANR0534W  
Transaction failed for session session number for node node name (client  
platform) - size estimate exceeded and server is unable to obtain additional  
space in storage pool pool name.  
Explanation: The server ends a database update transaction for the specified  
session because the size estimate provided by the client is too small. The server has  
attempted to obtain additional space in the indicated storage pool, but was unable to  
do so.  
System Action: The specified session is ended and server operation continues. If  
pool name is a random access storage pool with caching enabled, it is also possible  
that additional space can be made available in this storage pool by eliminating  
66  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cached files. When the server allocates space based on the size estimate provided by  
the client, it frees space occupied by cached files if this space is needed to obtain  
the estimated space. However, if the server later determines that the file size  
estimate was too low, it attempts to obtain additional space that is not utilized, but  
does not delete cached files to do so. If the client sending the data has the option  
COMPRESSALWAYS YES set, it is possible that a file grew during the  
compression operation and when the client sent it to the server it exceeded the space  
available in storage pool pool name.  
User Response: This message may indicate that there is no additional space in  
pool name. The following are possible circumventions:  
An authorized administrator can issue the DEFINE VOLUME command to add  
storage to this pool.  
If the suspected cause of the failure is that pool name is a DISK storage pool and  
that space in use by cached files was not freed, turn off caching for the storage pool  
and issue the MOVE DATA command for the volumes in pool pool name.  
If the suspected cause of the failure is that a file grew in size during compression  
on the client, another possible circumvention is to set the COMPRESSALWAYS  
option in the client options file to NO and retry the operation. This may allow the  
client to accurately report the file size and possibly avoid the out of space condition  
in the storage pool.  
ANR0535W  
Transaction failed for session session number for node node name (client  
platform) - insufficient mount points available to satisfy the request.  
Explanation: The server was unable to allocate sufficient mount points to process  
the transaction.  
System Action: The operation is ended and server operation continues.  
User Response: If necessary, make more mount points available.  
ANR0536W  
Transaction failed for session session number for node node name (client  
platform) - downlevel client does not support format of stored files.  
Explanation: A client attempts to perform an operation involving files that are  
stored in a format that is not supported by that client level.  
System Action: The operation is ended and server operation continues.  
User Response: Upgrade the client to a later level.  
Tivoli Storage Manager Messages  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0540W  
Retrieve or restore failed for session session number for node node name (client  
platform) - data integrity error detected.  
Explanation: The server ends a file retrieval operation for the specified session  
because an internal database integrity error has been encountered on the server.  
System Action: The server ends the specified session and continues operation.  
User Response: Contact your service representative.  
ANR0541W  
Retrieve or restore failed for session session number for node node name (client  
platform) - error on input storage device.  
Explanation: The server ends a client retrieval or restore operation for the  
specified session because an I/O error has been encountered by the server in reading  
from a device.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Query the activity log to find messages preceding this one that  
specify the device that is failing. Storage pool volumes can be varied offline (by  
using the VARY OFFLINE command), or the server may need to be shut down by  
using the HALT command to correct the hardware problem. After the problem is  
corrected, the client may try the operation again.  
ANR0542W  
Retrieve or restore failed for session session number for node node name (client  
platform) - storage media inaccessible.  
Explanation: The server ends a client retrieval or restore operation for the  
specified session because a needed storage pool volume has been varied offline.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Use the VARY ONLINE command to vary offline storage  
volumes online in the storage hierarchy, and make them available to client nodes for  
file storage.  
ANR0543W  
Retrieve or restore failed for session session number for node node name (client  
platform) - data transfer interrupted.  
Explanation: The database transaction associated with session session number was  
aborted because data transfer to or from data storage was interrupted by an external  
event.  
System Action: The session is canceled and server operation continues.  
68  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the messages issued prior to this message to determine  
why the data transfer was interrupted. Attempt the client operation again, if the  
problem can be resolved.  
ANR0544W  
Retrieve or restore failed for session session number for node node name (client  
platform) - thread resource not available.  
Explanation: The server ends a file retrieval or restore operation for the specified  
session because sufficient memory is not available for starting additional processes  
on the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0545W  
Retrieve or restore failed for session session number for node node name (client  
platform) - insufficient memory.  
Explanation: The server ends a file retrieval or restore operation for the specified  
session because sufficient memory is not available on the server.  
System Action: The server ends the specified session and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0546W  
Retrieve or restore failed for session session number for node node name (client  
platform) - internal server error detected.  
Explanation: The server ends a file retrieval or restore operation for the specified  
session because an internal logic error is detected in the server program.  
System Action: The server ends the specified session and continues operation.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Tivoli Storage Manager Messages  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0547E  
Invalid data was encountered in the command processor output stream: output  
formatting terminated for the last command entered.  
Explanation: The server console session encounters an error in formatting output  
from a command.  
System Action: The command output is discarded and server operation continues.  
User Response: Use the server QUERY command to determine if the command  
you entered had the desired affect in the server. Use the QUERY ACTLOG  
command to see if a server error condition (like out of memory) occurred prior to  
the command. Resolve the error if it is found. Contact your service representative if  
you cannot resolve the error, or if an error is not found.  
ANR0548W  
Retrieve or restore failed for session session number for node node name (client  
platform) processing filespace filespace for file file name stored as storage  
repository - data integrity error detected.  
Explanation: The server ends a file retrieval operation for the specified session  
because an internal database integrity error has been encountered on the server.  
System Action: The server ends the specified session and continues operation.  
User Response: Re-try the restore or retrieve operation and if the file is also  
backed up in a copy storage pool, the operation will attempt to read the file from  
the alternate location.  
ANR0566W  
Retrieve or restore failed for session session number for node node name (client  
platform) - file was deleted from data storage during retrieval.  
Explanation: The server ends a file retrieval operation for the specified session  
because the file has been deleted from data storage by another process before  
retrieval is complete.  
System Action: The server ends the specified session and continues operation.  
User Response: Contact your administrator to find out if DELETE FILESPACE,  
DELETE VOLUME, or inventory expiration processes are running; these processes  
can delete data storage files during retrieval. Reissue the restore or retrieve  
operation and specify a different file version.  
ANR0567W  
Retrieve or restored failed for session session number for node node name (client  
platform) - insufficient mount points available to satisfy the request.  
Explanation: The server was unable to allocate sufficient mount points to process  
the retrieve or restore operation.  
System Action: The operation is ended and server operation continues.  
70  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If necessary, make more mount points available.  
ANR0568W  
Session session number for admin admin name (client platform) terminated -  
connection with client severed.  
Explanation: The specified admin session is ended because the communications  
link has been closed by a network error or by the client program.  
System Action: Server operation continues.  
User Response: If a user breaks out of a client program, this message will be  
displayed on the server as the connection is suddenly closed by the client. A  
network failure can also cause this message to be displayed. If a large number of  
these messages occur simultaneously, check the network for failure and correct any  
problems.  
ANR0569I  
Object not processed for node name: type=type, file space=filespace name,  
object=object name.  
Explanation: An error occurred. The object for node name, identified by type, file  
space and object name was not processed.  
System Action: Server action is defined by the error that occurred.  
User Response: Issue QUERY ACTLOG to determine the source of the error.  
ANR0570E  
Export command: Invalid value for DURUNITS parameter detected while  
exporting administrative schedule schedule name - default or existing value is  
used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the DURUNITS parameter for administrative schedule schedule  
name.  
System Action: Export processing continues, but the exported data contains an  
unknown DURUNITS value for this schedule. If this data is imported, the server  
uses the default or existing DURUNITS value.  
User Response: Update the DURUNITS value for this schedule and restart the  
export command. Alternatively, the export data with the unknown value can be used,  
and the DURUNITS value can be checked and updated after import processing has  
been performed.  
Tivoli Storage Manager Messages  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0571E  
Export command: Invalid value for PERUNITS parameter detected while  
exporting administrative schedule schedule name - default or existing value is  
used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the PERUNITS parameter for administrative schedule schedule  
name.  
System Action: Export processing continues, but the exported data will contain an  
unknown PERUNITS value for this schedule. If this data is imported, the server  
uses the default or existing PERUNITS value.  
User Response: Update the PERUNITS value for this schedule and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the PERUNITS value after import processing has been performed.  
ANR0572E  
Export command: Invalid value for DAYOFWEEK parameter detected while  
exporting administrative schedule schedule name - default or existing value is  
used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the DAYOFWEEK parameter for administrative schedule schedule  
name.  
System Action: Export processing continues, but the exported data contains an  
unknown DAYOFWEEK value for this schedule. If this data is imported, the server  
uses the default or existing DAYOFWEEK value.  
User Response: Update the DAYOFWEEK value for this schedule and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the DAYOFWEEK value after import processing has been  
performed.  
ANR0573I  
Export/import command: Processing administrative schedule schedule name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the schedule definition information  
for administrative schedule schedule name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
72  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0574E  
Import command: Invalid value for DURUNITS or PERUNITS parameter in  
exported data for administrative schedule schedule name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the DURUNITS or PERUNITS parameter for  
administrative schedule schedule name.  
System Action: Processing of the command continues. If a later command is  
issued that causes the data to be imported, the default or existing values are used for  
DURATION, DURUNITS, PERIOD, and PERUNITS.  
User Response: If the data is imported with a later command, verify that the  
correct values for DURATION, DURUNITS, PERIOD, and PERUNITS are used for  
this schedule.  
ANR0575E  
Import command: Invalid value for DAYOFWEEK parameter in exported data  
for administrative schedule schedule name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the DAYOFWEEK parameter for administrative schedule  
schedule name.  
System Action: Processing of the command continues. If a later command is  
issued that causes the data to be imported, the default or existing DAYOFWEEK  
value is used.  
User Response: If the data is imported with a later command, verify that the  
correct DAYOFWEEK value is used for this schedule.  
ANR0576E  
Import command: Invalid value for DURUNITS or PERUNITS parameter in  
exported data - administrative schedule schedule name defined with default  
values for DURATION, DURUNITS, PERIOD, and PERUNITS.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DURUNITS or PERUNITS parameter for administrative  
schedule schedule name.  
System Action: Processing of the command continues, by using the default values  
for DURATION, DURUNITS, PERIOD, and PERUNITS.  
User Response: Verify that the correct values have been used for DURATION,  
DURUNITS, PERIOD, and PERUNITS. Update these values, if necessary.  
Tivoli Storage Manager Messages  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0577E  
ANR0578E  
ANR0579E  
Import command: Invalid value for DAYOFWEEK parameter in exported data -  
administrative schedule schedule name defined with default DAYOFWEEK  
value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DAYOFWEEK parameter for administrative schedule schedule  
name.  
System Action: Processing of the command continues, by using the default  
DAYOFWEEK value for this schedule.  
User Response: Verify that the correct DAYOFWEEK value has been used for this  
schedule. Update this value, if necessary.  
Import command: Invalid value for DURUNITS or PERUNITS parameter in  
exported data - existing values for DURATION, DURUNITS PERIOD, and  
PERUNITS for administrative schedule schedule name were not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DURUNITS or PERUNITS parameter for administrative  
schedule schedule name.  
System Action: Processing of the command continues, by using the existing values  
for DURATION, DURUNITS, PERIOD, and PERUNITS.  
User Response: Verify that the correct values have been used for DURATION,  
DURUNITS, PERIOD, and PERUNITS. Update these values, if necessary.  
Import command: Invalid value for DAYOFWEEK parameter in exported data -  
existing DAYOFWEEK value for administrative schedule schedule name was  
not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DAYOFWEEK parameter for administrative schedule schedule  
name.  
System Action: Processing of the command continues, by using the existing  
DAYOFWEEK value for this schedule.  
User Response: Verify that the correct DAYOFWEEK value has been used for this  
schedule. Update this value, if necessary.  
74  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0580E  
Export command: Invalid value for SPACEMGTECHNIQUE parameter  
detected while exporting management class management class name in domain  
domain name, set policy set name - default or existing value is used during  
import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the SPACEMGTECHNIQUE parameter for management class  
management class name in domain domain name, policy set policy set name.  
System Action: Export processing continues, but the exported data contains an  
unknown SPACEMGTECHNIQUE value for this management class. If this data is  
imported, the default or existing SPACEMGTECHNIQUE value is used.  
User Response: Update the SPACEMGTECHNIQUE value for this copy group  
and restart the export. Alternatively, use the export data with the unknown value,  
and check and update the SPACEMGTECHNIQUE value after import processing  
has been performed.  
ANR0581E  
Export command: Invalid value for MIGREQUIRESBKUP parameter detected  
while exporting management class management class name in domain domain  
name, set policy set name - default or existing value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the MIGREQUIRESBKUP parameter for management class  
management class name in domain domain name, policy set policy set name.  
System Action: Export processing continues, but the exported data contains an  
unknown value for this management class. If this data is imported, the default or  
existing MIGREQUIRESBKUP value is used.  
User Response: Update the MIGREQUIRESBKUP value for this copy group and  
restart the export. Alternatively, use the export data with the unknown value, and  
check and update the MIGREQUIRESBKUP value after import processing has been  
performed.  
ANR0582E  
Import command: Invalid value for SPACEMGTECHNIQUE parameter in  
exported data for management class management class name in domain domain  
name, set policy set name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the SPACEMGTECHNIQUE parameter for management  
class management class name, in policy domain domain name, policy set policy set  
name.  
System Action: Processing of the command continues. If a later command is  
issued that causes the data to be imported, the default or existing  
SPACEMGTECHNIQUE value is used.  
Tivoli Storage Manager Messages  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None. If the data is imported with a later command, verify that  
the correct SPACEMGTECHNIQUE value is used for this management class.  
ANR0583E  
Import command: Invalid value for SPACEMGTECHNIQUE parameter in  
exported data - management class management class name in domain domain  
name, set policy set name defined with default SPACEMGTECHNIQUE value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the SPACEMGTECHNIQUE parameter for management class  
management class name, in policy domain domain name, policy set policy set name.  
System Action: Processing of the command continues, by using the default  
SPACEMGTECHNIQUE value for this management class.  
User Response: Verify that the correct SPACEMGTECHNIQUE value has been  
used for this management class. Update this value, if necessary.  
ANR0584E  
Import command: Invalid value for SPACEMGTECHNIQUE parameter in  
exported data - SPACEMGTECHNIQUE value for management class  
management class name in domain domain name, set policy set name was not  
updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the SPACEMGTECHNIQUE parameter for management class  
management class name, in policy domain domain name, policy set policy set name.  
System Action: Processing of the command continues, by using the existing  
SPACEMGTECHNIQUE value for this management class.  
User Response: Verify that the correct SPACEMGTECHNIQUE value has been  
used for this management class. Update this value, if necessary.  
ANR0585E  
Import command: Invalid value for MIGREQUIRESBKUP parameter in  
exported data for management class management class name in domain domain  
name, set policy set name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the MIGREQUIRESBKUP parameter for management class  
management class name, in policy domain domain name, policy set policy set name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing MIGREQUIRESBKUP value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct MIGREQUIRESBKUP value is used for this management class.  
76  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0586E  
Import command: Invalid value for MIGREQUIRESBKUP parameter in  
exported data - management class management class name in domain domain  
name, set policy set name defined with default MIGREQUIRESBKUP value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the MIGREQUIRESBKUP parameter for management class  
management class name, in policy domain domain name, policy set policy set name.  
System Action: Processing of the command continues, by using the default  
MIGREQUIRESBKUP value for this management class.  
User Response: Verify that the correct MIGREQUIRESBKUP value has been used  
for this management class. Update this value, if necessary.  
ANR0587E  
Import command: Invalid value for MIGREQUIRESBKUP parameter in  
exported data - MIGREQUIRESBKUP value for management class management  
class name in domain domain name, set policy set name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the MIGREQUIRESBKUP parameter.  
System Action: Processing of the command continues, by using the existing  
MIGREQUIRESBKUP value for this management class.  
User Response: Verify that the correct MIGREQUIRESBKUP parameter has been  
used for this management class. Update this value, if necessary.  
ANR0588E  
Import command: Server is down-level compared to export data version version  
number.  
Explanation: An attempt is made to import data to a down-level server. The server  
on which the import is performed must be at the same or later level than the server  
from which the data was exported.  
System Action: The import process ends and server operation continues.  
User Response: Import to a server that is at the same or later level than the server  
from which the export was performed.  
ANR0589E  
Import command: Preview processing terminated abnormally - server is  
down-level.  
Explanation: Processing for the command import command in preview mode ends  
when it is determined that the server is down-level compared to the export data.  
System Action: Import processing ends and server operation continues.  
User Response: Import to a server that is at the same or later level than the server  
from which the export was performed.  
Tivoli Storage Manager Messages  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0590E  
Import command: Processing terminated abnormally - server is down-level.  
Explanation: Processing for the command import command ends when it is  
determined that the server is down-level compared to the export data.  
System Action: Import processing ends and server operation continues.  
User Response: Import to a server that is at the same or later level than the server  
from which the export was performed.  
ANR0591E  
Export/import command: Invalid value for FILELIST parameter - parameter  
value.  
Explanation: The value (parameter value) specified for the FILELIST parameter  
in command export/import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid FILELIST parameter.  
For information on valid values for the FILELIST parameter for the command, refer  
to the Administrators Reference for your particular platform.  
ANR0592E  
Export/import command: Invalid value for TOC parameter - parameter value.  
Explanation: The value (parameter value) specified for the TOC parameter in  
command export/import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid TOC parameter. For  
information on valid values for the TOC parameter for the command, refer to the  
Administrators Reference for your particular platform.  
ANR0593E  
Export/import command: Invalid value for NOSPAN parameter - parameter  
value.  
Explanation: The value (parameter value) specified for the NOSPAN parameter in  
command export/import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid NOSPAN parameter.  
For information on valid values for the NOSPAN parameter for the command, refer  
to the Administrators Reference for your particular platform.  
ANR0594E  
device class: NOSPAN parameter can only be used with a 3590 device class.  
Explanation: The device class specified must be a 3590 device class when  
NOSPAN is set to True.  
78  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid NOSPAN/Device Class  
parameter. For information on valid values for the NOSPAN parameter for the  
command, refer to the Administrators Reference for your particular platform.  
ANR0596W  
Space-managed object object name for client node node name, filespace filespace  
name already exists on the server - it will be skipped.  
Explanation: While attempting to import a spaced-managed object, the server  
discovers that the object already exists. The space-managed object is skipped.  
System Action: Server operation continues.  
User Response: None.  
ANR0597W  
IMPORT: Space management attributes in management class management class  
name for domain domain name is not defined - default management class will be  
used.  
Explanation: During import processing, the server finds that the space  
management attributes for a space-managed file being imported does not exist in the  
active policy set for the domain to which the node is assigned.  
System Action: The default management class for the node’s policy domain is  
bound to the space-managed file and import processing continues.  
User Response: If you want to define the missing management class, an  
authorized administrator may cancel the import operation, define the missing space  
management attributes or management class for the domain, and process the import  
operation again.  
ANR0598W  
IMPORT: Space management attributes not found for default management  
class in domain domain name - space managed files bound to management class  
management class name in this domain cannot be imported.  
Explanation: During import processing, the server finds that a management class  
bound to a space-managed file being imported does not exist in the active policy set  
for the domain to which the node is assigned. When trying to rebind the  
space-managed file to the default management class for the domain, the server finds  
that the space-managed attributes are not defined for the default management class.  
System Action: The file is not imported; import processing continues.  
User Response: If you want to define the missing copy group, an authorized  
administrator may cancel the import operation, define the missing space  
management attributes or management class for the domain, and process the import  
operation again.  
Tivoli Storage Manager Messages  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0599E  
Export/import command: Invalid volume name volume name specified for device  
class device class name.  
Explanation: One of the volume names specified in the VOLUMENAMES  
parameter for an import or export command is not a valid volume name for the  
device class specified in the DEVCLASS parameter.  
System Action: The export or import command fails.  
User Response: Specify volume names in the VOLUMENAMES parameter that  
are valid for the device class specified in the DEVCLASS parameter.  
ANR0600I  
Export command: No matching policy domains found for exporting.  
Explanation: The background export process does not find any policy domains  
that match the specification entered in the export command.  
System Action: The export process continues and no policy domains are exported  
from the server.  
User Response: None.  
ANR0601I  
Export command: No policy sets found in policy domain domain name for  
exporting.  
Explanation: The background export process does not find any policy sets defined  
in domains matching domain name.  
System Action: The export process continues and no policy sets are exported from  
the domain.  
User Response: None.  
ANR0602I  
Export command: No management classes were found in policy domain domain  
name for exporting.  
Explanation: The background export process does not find any management  
classes defined in policy domains matching domain name.  
System Action: The export process continues and no management classes are  
exported from the domain.  
User Response: None.  
ANR0603I  
Export command: No copy groups were found in policy domain domain name for  
exporting.  
Explanation: The background export process does not find any copy groups  
defined in policy domains matching domain name.  
80  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The export process continues and no copy groups are exported  
from the domain.  
User Response: None.  
ANR0604I  
Export command: No schedules were found in policy domain domain name for  
exporting.  
Explanation: The background export process does not find any schedules defined  
for policy domains matching domain name.  
System Action: The export process continues and no schedules are exported for  
the domain.  
User Response: None.  
ANR0605I  
Export command: No schedule associations were found in policy domain domain  
name for exporting.  
Explanation: The background export process does not find any schedule node  
associations defined for policy domains matching domain name.  
System Action: The export process continues and no schedule associations are  
exported for the domain.  
User Response: None.  
ANR0606I  
ANR0607I  
ANR0608I  
Export command: No node definitions were found for exporting.  
Explanation: The background export process does not find any node definitions to  
export as specified in the command export command.  
System Action: The export process continues.  
User Response: None.  
Export command: No administrator definitions were found for exporting.  
Explanation: The background export process does not find any administrator  
definitions to export as specified in the command export command.  
System Action: The export process continues.  
User Response: None.  
Export command: No file spaces were found for exporting.  
Explanation: The background export process does not find any file space  
definitions to export as specified in the command export command.  
Tivoli Storage Manager Messages  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The export process continues.  
User Response: None.  
ANR0609I  
Command started as process process ID.  
Explanation: A background process has been started to service the command  
command. The background process is defined as process process ID.  
System Action: Server operation continues.  
User Response: To query the progress of the background process, use the QUERY  
PROCESS command. To cancel the background process, use the CANCEL  
PROCESS command. Use the process ID number to specify this specific process.  
ANR0610I  
Command started by administrator name as process process ID.  
Explanation: A background process has started to service the command command  
entered by administrator administrator name. The background process is defined as  
process process ID.  
System Action: Server operation continues.  
User Response: To query the progress of the background process, use the QUERY  
PROCESS command. To cancel the background process, use the CANCEL  
PROCESS command. Use the process ID number to specify this specific process.  
ANR0611I  
Command started by administrator name as process process ID has ended.  
Explanation: The background process to service the command command by  
administrator administrator name has completed processing.  
System Action: The specified process ends, and server operation continues.  
User Response: None.  
ANR0612I  
Import command: Reading EXPORT SERVER data from server server name  
exported export date export time.  
Explanation: The background import process to service the command import  
command is importing information exported from server server name with the  
EXPORT SERVER command on export date at export time.  
System Action: Import processing continues.  
User Response: None.  
82  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0613I  
ANR0614I  
ANR0615I  
ANR0616I  
Import command: Reading EXPORT POLICY data from server server name  
exported export date export time.  
Explanation: The background import process to service the command import  
command is importing information exported from server server name with the  
EXPORT POLICY command on export date at export time.  
System Action: Import processing continues.  
User Response: None.  
Import command: Reading EXPORT ADMIN data from server server name  
exported export date export time.  
Explanation: The background import process to service the command import  
command is importing information exported from server server name with the  
EXPORT ADMIN command on export date at export time.  
System Action: Import processing continues.  
User Response: None.  
Import command: Reading EXPORT NODE data from server server name  
exported export date export time.  
Explanation: The background import process to service the command import  
command is importing information exported from server server name with the  
EXPORT NODE command on export date at export time.  
System Action: Import processing continues.  
User Response: None.  
Export/import command: Preview processing completed successfully.  
Explanation: The background export or import process to service the command  
export/import command in preview (Preview=Yes) mode has completed successfully.  
System Action: Export or import processing for the command completes. Statistics  
on the projected number and type of objects moved, together with the projected  
total number of bytes copied, are displayed on the server console following this  
message.  
User Response: None.  
Tivoli Storage Manager Messages  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0617I  
Export/import command: Processing completed with status status.  
Explanation: The background export or import process to service the command  
export/import command has completed with status status. If the status is  
INCOMPLETE, some files have been skipped due to errors reading or writing the  
file.  
System Action: Export or import processing for the command completes. Statistics  
on the number and type of objects moved, together with the total number of bytes  
copied, are displayed on the server console following this message. A summary of  
the number of files that were skipped is also displayed.  
User Response: None.  
ANR0618I  
Export/import command: Preview processing canceled before completion.  
Explanation: The background export or import process to service the command  
export/import command in preview (Preview=Yes) mode has been canceled with the  
CANCEL PROCESS command.  
System Action: Export or import processing for the command ends. Statistics on  
the projected number and type of objects moved, together with the projected total  
number of bytes copied, are displayed on the server console following this message.  
User Response: None.  
ANR0619I  
Command: Processing canceled before completion.  
Explanation: The background process to service the command command has been  
canceled with the CANCEL PROCESS command.  
System Action: Processing for the command command ends. Statistics on the  
number and type of objects moved, together with the total number of bytes copied,  
are displayed on the server console following this message.  
User Response: None.  
ANR0620I  
Export/import command: Copied number domain(s).  
Explanation: The background export or import process to service the command  
export/import command copies number policy domain definitions from the server  
database to export media or from export media into the server database. Data is not  
actually moved if Preview=Yes is specified in the command export/import  
command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
84  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0621I  
Export/import command: Copied number policy sets.  
Explanation: The background export or import process to service the command  
export/import command copies number policy set definitions from the server  
database to export media or from export media into the server database. Data is not  
actually moved if Preview=Yes is specified in the command export/import  
command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
ANR0622I  
ANR0623I  
ANR0624I  
Export/import command: Copied number management classes.  
Explanation: The background export or import process to service the command  
export/import command copies number management class definitions from the  
server database to export media or from export media into the server database. Data  
is not moved if Preview=Yes is specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Export/import command: Copied number copy groups.  
Explanation: The background export or import process to service the command  
export/import command copies number copy group definitions from either the server  
database to export media or from export media into the server database. Data is not  
moved if Preview=Yes is specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Export/import command: Copied number schedules.  
Explanation: The background export or import process to service the command  
export/import command copies number schedule definitions from either the server  
database to export media or from export media into the server database. Data is not  
moved if Preview=Yes is specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0625I  
ANR0626I  
ANR0627I  
Export/import command: Copied number administrators.  
Explanation: The background export or import process to service the command  
export/import command copies number administrator definitions from either the  
server database to export media or from export media into the server database. Data  
is not moved if Preview=Yes is specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Export/import command: Copied number node definitions.  
Explanation: The background export or import process to service the command  
export/import command copies number client node definitions from the server  
database to export media or from export media into the server database. Data is not  
moved if Preview=Yes is specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Export/import command: Copied filespace number file space archive number  
archive files, backup number backup files, and spacemg number space managed  
files.  
Explanation: The background export or import process to service the command  
export/import command copies filespace number client file space definitions, archive  
number archive file copies, backup number backup file copies, and spacemg number  
space-managed files from either the server database to export media or from import  
media into the server database. Data is not actually moved if Preview=Yes is  
specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
ANR0629I  
Export/import command: Copied number bytes of data.  
Explanation: The background export or import process to service the command  
export/import command copies number bytes of data from the server database and  
data storage to the export media or from the export media to the server database and  
data storage. Data is not moved if Preview=Yes is specified in the command  
86  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
export/import command. This figure can be used during export preview processing  
to estimate the number of removable media volumes needed to hold the exported  
information from the server.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
ANR0630I  
ANR0631I  
ANR0632I  
Export/import command: Copied number kilobytes of data.  
Explanation: The background export or import process to service the command  
export/import command copies number kilobytes of data from the server database  
and data storage to the export media or from the export media to the server database  
and data storage. This figure can be used during export preview processing to  
estimate the number of removable media volumes needed to hold the exported  
information from the server.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Export/import command: Copied number megabytes of data.  
Explanation: The background export or import process to service the command  
export/import command copies number megabytes of data from the server database  
and data storage to the export media or from the export media to the server database  
and data storage. This figure can be used during export preview processing to  
estimate the number of removable media volumes needed to hold the exported  
information from the server.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
Export/import command: Copied number gigabytes of data.  
Explanation: The background export or import process to service the command  
export/import command copies number gigabytes of data from the server database  
and data storage to the export media or from the export media to the server database  
and data storage. This figure can be used during export preview processing to  
estimate the number of removable media volumes needed to hold the exported  
information from the server.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
Tivoli Storage Manager Messages  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR0633I  
Export/import command: Copied number terabytes of data.  
Explanation: The background export or import process to service the command  
export/import command copies number terabytes of data from the server database  
and data storage to the export media or from the export media to the server database  
and data storage. This figure can be used during export preview processing to  
estimate the number of removable media volumes needed to hold the exported  
information from the server.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
ANR0634I  
Export/import command: Detected number errors.  
Explanation: The background export or import process to service the command  
export/import command detects number errors while copying information from the  
server database and data storage to the export media or from the export media to the  
server database and data storage.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: Examine the server messages issued prior to this message to view  
the error. Use the QUERY ACTLOG command to view the activity log and search  
for messages.  
ANR0635I  
Export/import command: Processing node node name in domain domain name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the client node definition  
information for node node name. The node will be imported to domain domain  
name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
ANR0636I  
Import command: Processing file space filespace name for node node name as file  
space new filespace name.  
Explanation: The background import process to service the command import  
command is currently processing the client file space definition information for file  
space filespace name belonging to client node node name. The file space is  
imported under the name new filespace name. During import processing, file spaces  
88  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
defined for clients are not replaced, and file copy information in the file spaces are  
imported to new file space names so that client file copies are not mixed with  
existing definitions. Import processing can then create file spaces with names  
generated by the import processor for client nodes that existed prior to the import  
operation.  
System Action: Import processing for the command continues.  
User Response: None; however, clients may want to examine the contents of the  
file space with the name new filespace name so that they know where certain file  
copies are kept.  
ANR0637I  
ANR0638I  
ANR0639I  
ANR0640I  
Export/import command: Processing file space filespace name for node node name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing client node file space information for  
file space filespace name belonging to client node node name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
Export/import command: Processing administrator administrator name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the administrator definition  
information for administrator administrator name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
Export/import command: Processing domain domain name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the policy domain definition  
information for domain domain name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
Export/import command: Processing policy set set name in policy domain domain  
name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the policy set definition information  
for policy set set name belonging to policy domain domain name.  
System Action: Export or import processing for the command continues.  
Tivoli Storage Manager Messages  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR0641I  
ANR0642I  
ANR0643I  
ANR0644I  
Export/import command: Processing management class class name in domain  
domain name, set set name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the management class definition  
information for management class class name belonging to policy set set name in  
policy domain domain name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
Export/import command: Processing backup copy group in domain domain name,  
set set name, management class class name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the backup copy group definition  
information for management class class name belonging to policy set set name in  
policy domain domain name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
Export/import command: Processing archive copy group in domain domain name,  
set set name, management class class name.  
Explanation: The background export process to service the command  
export/import command is currently processing the archive copy group definition  
information for management class class name belonging to policy set set name in  
policy domain domain name.  
System Action: Export processing for the command continues.  
User Response: None.  
Export command: Processing copy group of unknown type in domain domain  
name, set set name, management class class name.  
Explanation: The background export or import process to service the command  
export command is currently processing copy group definition information for  
management class class name belonging to policy set set name in policy domain  
domain name. The type of copy group being processed is unknown.  
System Action: Export or import processing for the command continues. The  
import or export process assumes that the copy group is a backup copy group.  
90  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: After policy definitions are imported, use the QUERY  
MGMTCLASS and QUERY COPYGROUP commands to query the server  
definitions for management class class name to ensure that the copy groups defined  
have the desired attributes and types. Alternatively, the copy group can be deleted  
and defined with the correct type, and then the export command can be issued  
again.  
ANR0645I  
ANR0646I  
ANR0647I  
ANR0648I  
Export/import command: Processing schedule schedule name in domain domain  
name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing the schedule definition information  
for schedule schedule name belonging to policy domain domain name.  
System Action: Export or import processing for the command continues.  
User Response: None.  
Export/import command: message  
Explanation: The background export or import process to service the command  
export/import command has received the message message from the server.  
System Action: Export or import processing for the command continues, but errors  
may have been encountered.  
User Response: Examine the documentation for the message message and resolve  
the problem reported.  
Cancel in progress  
Explanation: The export or import operation has been canceled and will end when  
resources have been freed for the background process. This message may be  
displayed in response to a QUERY PROCESS command for an export or import  
operation.  
System Action: Server operation continues.  
User Response: None.  
Have copied the following:  
Explanation: The export or import operation has copied the number and types of  
objects displayed. This message may be displayed in response to a QUERY  
PROCESS command for an export or import operation.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0649I  
Import command: Domain domain name does not exist - the system will attempt  
to import node node name to domain STANDARD.  
Explanation: The background import process to service the command import  
command is currently processing client node node name. This node was assigned to  
domain domain name at the time of export. However, domain domain name does  
not exist on the server to which the import is being performed.  
System Action: Import processing continues, but node node name will be assigned  
to domain STANDARD during import unless one of the following conditions exist:  
Preview=Yes  
Node node name is already registered and Replacedefs=No  
Domain STANDARD does not exist  
User Response: If Preview=Yes, consider defining domain domain name before  
nodes are actually imported. Otherwise, domain domain name can be created after  
the node is imported and the UPDATE NODE command can be used to assign the  
node to domain domain name.  
ANR0650W  
IMPORT: Archive copygroup copy group name in management class  
management class name for domain domain name is not defined, default  
management class will be used.  
Explanation: During import processing, the server finds that a management class  
or copy group bound to an archive file being imported does not exist in the active  
policy set for the domain to which the node is assigned.  
System Action: The default management class for the node’s policy domain is  
bound to the archive file and import processing continues.  
User Response: If you want to define the missing management class, an  
authorized administrator may cancel the import operation, define the missing  
management class or copy group for the domain, and process the import operation  
again.  
ANR0651W  
IMPORT: Backup copygroup copy group name in management class  
management class name for domain domain name is not defined, default  
management class will be used.  
Explanation: During import processing, the server finds that a management class  
or copy group bound to a backup file being imported does not exist in the active  
policy set for the domain to which the node is assigned.  
System Action: The default management class for the node’s policy domain is  
bound to the backup file copy and import processing continues.  
92  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If you want to define the missing management class, an  
authorized administrator may cancel the import operation, define the missing  
management class or copy group for the domain, and process the import operation  
again.  
ANR0652W  
ANR0653W  
ANR0655W  
IMPORT: Archive copygroup not found for default management class in  
domain domain name - archive files bound to management class management  
class name in this domain cannot be imported.  
Explanation: During import processing, the server finds that a management class  
or copy group bound to an archive file being imported does not exist in the active  
policy set for the domain to which the node is assigned. When trying to rebind the  
archive file to the default management class for the domain, the server finds that an  
archive copy group is not defined for the default management class.  
System Action: The file is not imported; import processing continues.  
User Response: If you want to define the missing copy group, an authorized  
administrator may cancel the import operation, define the missing management class  
or copy group for the domain, and process the import operation again.  
IMPORT: Backup copygroup not found for default management class in  
domain domain name - backup files bound to management class management  
class name in this domain cannot be imported.  
Explanation: During import processing, the server finds that a management class  
or copy group bound to a backup file being imported does not exist in the active  
policy set for the domain to which the node is assigned. When trying to rebind the  
backup file to the default management class for the domain, the server finds that a  
backup copy group is not defined for the default management class.  
System Action: The file is not imported; import processing continues.  
User Response: If you want to define the missing copy group, an authorized  
administrator may cancel the import operation, define the missing management class  
or copy group for the domain, and process the import operation again.  
Command: Retrieve or restore failed - file was deleted from data storage during  
retrieval.  
Explanation: The server ends a file retrieval operation for the specified command  
because the file has been deleted from data storage by another process before  
retrieval is complete.  
System Action: The server ends the command and continues operation.  
User Response: Contact your administrator to find out if DELETE FILESPACE,  
DELETE VOLUME, or inventory expiration processes are running; these processes  
Tivoli Storage Manager Messages  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
can delete data storage files during retrieval. Reissue the command after these  
processes have been completed or canceled.  
ANR0656W  
Export/import command: Skipped archive number archive files, backup number  
backup files, and spacemg number space managed files.  
Explanation: The background export or import process to service the command  
export/import command skipped archive number archive file copies, backup number  
backup file copies, and spacemg number space-managed files from either the server  
database to export media or from import media into the server database. Data is not  
actually moved if Preview=Yes is specified in the command export/import  
command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: Check previous messages for the names of the files that were not  
exported or imported, and problem determination information.  
ANR0657W  
Export command: Invalid authorization rule type rule type encountered for file  
space filespace name in node node name - both backup and archive will be  
assumed during import.  
Explanation: During import processing, the server encounters an invalid file space  
authorization rule type for the indicated file space and node.  
System Action: Server operation continues.  
User Response: After import processing is completed, ask the user of node node  
name to query the access rules and ensure that they are specified as desired. The  
user should correct any rules that grant access to objects that the user does not want  
others to access.  
ANR0658W  
Export command: The password for administrator administrator name could not  
be obtained. The value ’password value’ will be assumed: The system  
administrator may wish to change this password after importing administrator  
administrator name.  
Explanation: During processing of command export command, the export  
processor cannot obtain the password for administrator administrator name. The  
value password value is assigned as the password for the administrator on the export  
media.  
System Action: Processing of the command continues.  
User Response: After the administrative definition has been imported to another  
server, an authorized administrator should use the UPDATE ADMIN command to  
set a password for the administrator administrator name.  
94  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0659W  
Export command: The password for node node name could not be obtained. The  
value ’password value’ will be assumed: The system administrator may wish to  
change this password after importing node node name.  
Explanation: During processing of command export command, the export  
processor cannot obtain the password for client node node name. The value  
password value is assigned as the password for the client node on the export media.  
System Action: Processing of the command continues.  
User Response: After the client node definition has been imported to another  
server, an authorized administrator should use the UPDATE NODE command to set  
a password for the node node name.  
ANR0660E  
Command: Insufficient memory available in accessing data storage.  
Explanation: The server encounters a memory shortage in accessing data storage  
during command command operation.  
System Action: The command command operation ends and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0661E  
Command: Internal error encountered in accessing data storage.  
Explanation: The server encounters an internal error in accessing data storage  
while processing command command operation.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Use the QUERY ACTLOG command to examine messages prior  
to this error to determine the cause of the data storage failure. If the failure can be  
found and resolved, reissue the command command operation. If the failure cannot  
be found, contact your service representative for assistance in resolving the problem.  
ANR0662E  
Command: Output error encountered in accessing data storage.  
Explanation: The command command operation ends because an error has been  
encountered by the server in writing to a device. Possible reasons include:  
I/O error writing to a device  
No storage space.  
System Action: The command command operation ends and server operation  
continues.  
Tivoli Storage Manager Messages  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Query the activity log to find messages preceding this one to  
determine the cause of the error. After the problem is corrected, the command can  
be retried.  
ANR0663E  
Command: Data transfer was interrupted in accessing data storage.  
Explanation: The database transaction associated with command command  
operation failed because data transfer to or from data storage was interrupted by an  
external event.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Examine the messages issued prior to this message to determine  
why the data transfer was interrupted. Reissue the command command after the  
problem is resolved.  
ANR0664E  
Export/import command: Media not accessible in accessing data storage.  
Explanation: The server ends a transaction for an export or import operation  
because storage volumes are not available in the storage pools in which the client  
files are to be stored.  
System Action: The server ends the export or import operation and server  
operation continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy. The  
VARY ONLINE command can be used to vary offline storage volumes online in the  
storage hierarchy to make them available for file storage.  
ANR0665W  
Import command: Transaction failed - storage pool pool name is not defined.  
Explanation: The server rolls back a database update transaction for an import  
operation because the destination specified for a management class copy group  
specifies the named storage pool, but that storage pool does not exist.  
System Action: The import operation is ended and server operation continues.  
User Response: An administrator with policy authority over the client policy  
domain must correct management class definitions so that copy group destinations  
refer to defined storage pools, or the specified storage pool must be created by an  
authorized administrator.  
96  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0666W  
Import command: Transaction failed - object excluded by size in storage pool  
pool name and all successor pools.  
Explanation: The server ends a database update transaction for an import  
operation because the size of an imported file is larger than that allowed in the  
storage pool specified in the bound management class copy group for the file. No  
successor storage pools to the one specified on the copy group can accept the large  
file.  
System Action: The import operation is ended and server operation continues.  
User Response: The maximum file size for one or more of the storage pools in  
the storage hierarchy can be increased to accommodate the file. An authorized  
administrator can increase the MAXSIZE parameter by issuing the UPDATE  
STGPOOL command. Alternatively, the appropriate copygroup definition can be  
updated so that a different destination storage pool is specified.  
ANR0667W  
Import command: Transaction failed - no space available in storage pool pool  
name and all successor pools.  
Explanation: The server ends an import operation because the storage pool  
specified in a management class copy group does not contain enough free space to  
hold the files being imported. Successor storage pools to the one specified on the  
copy group do not contain enough free space.  
System Action: The import operation is ended and server operation continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy.  
ANR0668W  
Export/import command: Transaction failed - error on output storage device.  
Explanation: The server ends an export or import operation for the specified  
session because an I/O error has been encountered by the server in writing to a  
device.  
System Action: The server ends the export or import operation and server  
operation continues.  
User Response: Query the activity log to find messages preceding this one that  
specify the device that is failing. Storage pool volumes can be varied offline (by  
using the VARY OFFLINE command), or the server may need to be shut down by  
using the HALT command to correct the hardware problem. After the problem is  
corrected, the client may be able to try the operation again.  
Tivoli Storage Manager Messages  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0669W  
Export/import command: Transaction failed - data transfer interrupted.  
Explanation: The database transaction associated with an export or import  
operation failed because data transfer to or from data storage was interrupted by an  
external event.  
System Action: The export or import operation is ended and server operation  
continues.  
User Response: Examine the messages issued prior to this message to determine  
why the data transfer was interrupted. Attempt the export/import operation again  
after problem is resolved.  
ANR0670W  
Export/import command: Transaction failed - storage media inaccessible.  
Explanation: The server ends a transaction for an export or import operation  
because storage volumes are not available in the storage pools in which the client  
files are to be stored.  
System Action: The server ends the export or import operation and server  
operation continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy. The  
VARY ONLINE command can be used to vary offline storage volumes online in the  
storage hierarchy to make them available for file storage.  
ANR0671W  
Export/import command: Transaction failed - sufficient recovery log space is not  
available.  
Explanation: The server ends a database update transaction for an export or  
import operation because sufficient log space is not available on the server.  
System Action: The server ends the export or import operation and server  
operation continues.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log, and the EXTEND  
LOG command to extend the size of the log so that the new volumes are used.  
ANR0672W  
Export/import command: Transaction failed - sufficient database space is not  
available.  
Explanation: The server ends a database update transaction for an export or  
import operation because sufficient database space is not available on the server.  
System Action: The server ends the export or import operation and server  
operation continues.  
98  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: An authorized administrator can issue the DEFINE DBVOLUME  
command to add volumes for use by the database, and the EXTEND DB command  
to extend the size of the log so that the new volumes are used.  
ANR0673W  
Export/import command: Data storage retrieve or restore failed - data integrity  
error detected.  
Explanation: The server ends an export or import operation because an internal  
database integrity error has been encountered on the server.  
System Action: The server ends the export or import operation and continues  
operation.  
User Response: Contact your service representative.  
ANR0674W  
Export command: Retrieve failed - error on input storage device.  
Explanation: The server ends an export operation for the specified session because  
an I/O error has been encountered by the server in reading from a device. The  
object for which the I/O was issued is reported in a later message.  
System Action: Export processing skips this file, and continues operation.  
User Response: Query the activity log to find messages preceding this one that  
specify the device that is failing. Storage pool volumes can be varied offline (by  
using the VARY OFFLINE command), or the server may need to be shut down with  
the HALT command to correct the hardware problem.  
ANR0675E  
EXPORT/IMPORT: Error starting the Export/Import Session.  
Explanation: The server export/import process is not able to start the session to  
export information from the server or import information into the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0676E  
EXPORT/IMPORT: Invalid Communications Buffer State in SEND.  
Explanation: The server export/import process encounters a communications error  
in transferring information to or from the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0677E  
ANR0678E  
ANR0679E  
ANR0681E  
ANR0682E  
EXPORT/IMPORT: Invalid Communications Buffer State in RECEIVE.  
Explanation: The server export/import process encounters a communications error  
in transferring information to or from the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
EXPORT/IMPORT: Communications Failure in Sending verb typeverb.  
Explanation: The server export/import process encounters a communications error  
in using the verb type verb to transfer information to or from the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
EXPORT/IMPORT: Communications Failure in Receiving verb typeverb.  
Explanation: The server export/import process encounters a communications error  
in using the verb type verb to transfer information to or from the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
EXPORT/IMPORT: Authentication Failure.  
Explanation: The server export/import process encounters an authentication error  
in transferring information to or from the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
EXPORT/IMPORT: Communications Failure in Sending verb typeverb  
(command).  
Explanation: The server export/import process encounters a communications error  
in using the verb type verb to issue command command.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
ANR0683E  
EXPORT/IMPORT: Receive Buffer overflow.  
Explanation: The server export/import process encounters an overflow error in  
transferring information to or from the server.  
100  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
ANR0684E  
ANR0685E  
ANR0686E  
EXPORT/IMPORT: Communications failure: bad verb received (verb type).  
Explanation: The server encounters an invalid communications verb during export  
or import processing and is not able to continue processing.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
EXPORT/IMPORT: Internal error: Invalid table output handle detected.  
Explanation: The server export/import process encounters an internal error in  
transferring information to or from the server.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
Export/import command: Transaction failure - could not start database  
transaction.  
Explanation: During processing of command export/import command, a database  
transaction cannot be started in the server database.  
System Action: Processing of the command terminates.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0687E  
Export/import command: Transaction failure - could not commit database  
transaction.  
Explanation: During processing of command export/import command, a database  
transaction cannot be committed to the server database.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Tivoli Storage Manager Messages  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0688E  
Export/import command: Transaction failure - commit called when no  
transaction started.  
Explanation: During processing of command export/import command, a database  
transaction cannot be started in the server database.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0689W  
Import command: Client platform type (platform type) for imported node node  
name conflicts with an existing node with the same name - the node will not be  
imported.  
Explanation: During import processing, the server encounters an imported node  
definition that has the same name as an existing node, but has a different client  
platform type (for example, OS/2 or AIX). Because file data may not be compatible  
across different client platforms, the node is not imported.  
System Action: Import processing continues, and the named node is skipped by  
import processing.  
User Response: If you want to import the named node, cancel the import process,  
rename the existing node to a new name by using the RENAME NODE command,  
and run the import again. After you have imported the node, use the RENAME  
NODE command to set the node names as you desire.  
ANR0690E  
Export/import command: Transaction failure - server aborted the transaction  
(abort code).  
Explanation: During processing of command export/import command, a database  
transaction cannot be committed in the server database. The reason code abort code  
is returned.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0691E  
Export command: Error abort code writing export data.  
Explanation: During processing of command export command, an input/output  
error occurs when writing the exported information to the export media.  
102  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0692E  
Command: Out of space on sequential media, scratch media could not be  
mounted.  
Explanation: During command command processing, the process encounters an  
out-of-space condition writing to the sequential media. Command command ends  
when there is no more space on the sequential media for storing data and  
SCRATCH=NO has been specified on command command.  
System Action: Command command processing ends. Server processing continues.  
User Response: Reissue the command and specify SCRATCH=YES or specify  
additional volume names on the command.  
ANR0693E  
ANR0694E  
ANR0695E  
Import command: Error abort code reading export data.  
Explanation: During processing of command import command, an input/output  
error occurs when reading the exported information from the export media.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Import command: Invalid record format (format code) detected on import.  
Explanation: During processing of command import command, an invalid record  
type is detected when reading the exported information from the export media.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Export command: Unexpected error error code encountered in receiving table  
output data.  
Explanation: During processing of command export command, an unexpected  
error is detected.  
Tivoli Storage Manager Messages  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0696E  
ANR0697E  
ANR0698E  
Export command: Output table error encountered - 0 columns reported in the  
table.  
Explanation: During processing of command export command, an unexpected  
error is detected.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Export command: Output table error encountered - not positioned to the first  
column in the table.  
Explanation: During processing of command export command, an unexpected  
error is detected.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Export/import command: Invalid value for FILEDATA parameter - parameter  
value.  
Explanation: The value (parameter value) specified for the FILEDATA parameter  
in command export/import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid FILEDATA parameter.  
For information on valid values for the FILEDATA parameter for the command,  
refer to the Administrators Reference for your particular platform.  
104  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0699E  
Export/import command: Device class DISK cannot be specified for this  
command.  
Explanation: The DEVCLASS value DISK cannot be specified for the command  
export/import command.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid device class. Issue the  
QUERY DEVCLASS command for a list of valid device classes for the server.  
ANR0700E  
Export/import command: Invalid value for PREVIEW parameter - parameter  
value.  
Explanation: The value (parameter value) specified for the PREVIEW parameter  
in command export/import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid PREVIEW parameter.  
For information on valid values for the PREVIEW parameter for the command,  
refer to the Administrators Reference for your particular platform.  
ANR0701E  
Export/import command: Invalid value for SCRATCH parameter - parameter  
value.  
Explanation: The value (parameter value) specified for the SCRATCH parameter  
in command export/import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid SCRATCH parameter.  
For information on valid values for the SCRATCH parameter for the command,  
refer to the Administrators Reference for your particular platform.  
ANR0705E  
Export command: The VOLUMENAMES parameter must be specified when  
SCRATCH=NO is specified.  
Explanation: The SCRATCH parameter is specified as NO for the command  
export command but the VOLUMENAMES parameter is not specified. When  
scratch volumes are not allowed, the VOLUMENAMES parameter must be  
specified to indicate the volumes that can be used for the command.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid VOLUMENAMES  
parameter. For information on valid parameter values for the command, refer to the  
Administrators Reference for your particular platform.  
Tivoli Storage Manager Messages  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0706E  
Export command: A device class must be specified unless PREVIEW=YES is  
specified.  
Explanation: The DEVCLASS parameter is not specified in the command export  
command. Unless PREVIEW=YES is specified, a DEVCLASS value must be  
specified.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid device class. Issue the  
QUERY DEVCLASS command for a list of valid device classes for the server.  
ANR0707E  
Export command: The FILESPACE parameter cannot be specified.  
Explanation: The FILESPACE parameter is specified for the command export  
command, but the FILEDATA parameter is specified as NONE, or is not specified  
and defaults to NONE. File spaces are only copied if the FILEDATA parameter is  
specified with a value other than NONE.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid FILEDATA parameter.  
For information on valid parameter values for the command, refer to the  
Administrators Reference for your particular platform.  
ANR0708E  
Import command: The FILESPACE parameter cannot be specified unless the  
FILEDATA parameter specifies that files should be imported.  
Explanation: The FILESPACE parameter is specified for the command import  
command, but the FILEDATA parameter is specified as NONE, or is not specified  
and defaults to NONE. File spaces are only copied if the FILEDATA parameter is  
specified with a value other than NONE.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid FILEDATA parameter.  
For information on valid parameter values for the command, refer to the  
Administrators Reference for your particular platform.  
ANR0709E  
Command: No matching nodes registered in the specified domains.  
Explanation: The DOMAIN parameter has been specified for this command, but  
no nodes matching the node name specification are found in the domains specified.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid combination of node  
and domain names. Use the QUERY NODE command to view the names of nodes  
in the domains that you are interested in exporting.  
106  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0710E  
ANR0711E  
ANR0712E  
ANR0713E  
Command: Unable to start background process.  
Explanation: The server command processor is not able to start a background  
process to perform the command command.  
System Action: The command process ends and server operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
Import command: Unable to start import process.  
Explanation: The server import command processor is not able to start a  
background process to perform the import operation.  
System Action: The export or import process ends and server operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
Import command: Invalid value for DATES parameter - parameter value.  
Explanation: The value (parameter value) specified for the DATES parameter in  
command import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid DATES parameter. For  
information on valid values for the DATES parameter for the command, refer to the  
Administrators Reference for your particular platform.  
Import command: Invalid value for REPLACEDEFS parameter - parameter  
value.  
Explanation: The value (parameter value) specified for the REPLACEDEFS  
parameter in command import command is not a valid value for this parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid REPLACEDEFS  
parameter. For information on valid values for the REPLACEDEFS parameter for  
the command, refer to the Administrators Reference for your particular platform.  
Tivoli Storage Manager Messages  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0714E  
ANR0715E  
ANR0716E  
Import command: The EXTFILE device class cannot be specified when the  
VOLUMENAMES parameter is specified.  
Explanation: An invalid combination of parameters has been entered for command  
import command. The EXTFILE device class cannot be used in combination with  
the VOLUMENAMES parameter.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command with the correct syntax.  
Import command: A device class must be specified.  
Explanation: The command import command has been specified, but does not  
include specification of the DEVCLASS parameter. The DEVCLASS parameter  
must be specified for this command.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid device class. For a list  
of valid device classes for the server, issue the QUERY DEVCLASS command.  
Import command: Invalid export data detected.  
Explanation: The command import command encounters invalid data on the  
export media while trying to import server information.  
System Action: The command fails and server operation continues.  
User Response: Ensure that the mounted export tapes are in the correct order  
(mounted in the same order as they were mounted during export). Reissue the  
command, and mount the tapes in the correct order. If the VOLUMENAMES  
parameter has been specified, make sure that the volume names in the command are  
specified in the correct order.  
ANR0717E  
Export/import command: Preview processing terminated abnormally -  
communications send or receive failed.  
Explanation: Processing for the command export/import command in preview  
mode has been terminated when an internal communications error is encountered in  
the server.  
System Action: Export/import processing is ended and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
108  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0718E  
Export/import command: Processing terminated abnormally - communications  
send or receive failed.  
Explanation: Processing for the command export/import command ends when an  
internal communications error is encountered in the server.  
System Action: Export/import processing is ended and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0719E  
Export/import command: Preview processing terminated abnormally -  
insufficient memory.  
Explanation: Processing for the command export/import command in preview  
mode is ended because sufficient memory is not available on the server.  
System Action: Export/import processing is ended and server operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0720E  
command: Processing terminated abnormally - insufficient memory.  
Explanation: Processing for the command ends because sufficient memory is not  
available on the server.  
System Action: Command processing is ended and server operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0721E  
Export/import command: Preview processing terminated abnormally -  
unexpected verb received from server.  
Explanation: Processing for the command export/import command in preview  
mode ends when an internal communications error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Tivoli Storage Manager Messages  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0722E  
Export/import command: Processing terminated abnormally - unexpected verb  
received from server.  
Explanation: Processing for the command export/import command ends when an  
internal communications error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0723E  
Export/import command: Preview processing terminated abnormally -  
transaction failure.  
Explanation: Processing for the command export/import command in preview  
mode ends when a database transaction error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0724E  
Export/import command: Processing terminated abnormally - transaction failure.  
Explanation: Processing for the command export/import command ends when a  
database transaction error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0725E  
Export/import command: Preview processing terminated abnormally -  
authentication failure.  
Explanation: Processing for the command export/import command in preview  
mode ends when an authentication error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
110  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0726E  
Export/import command: Processing terminated abnormally - authentication  
failure.  
Explanation: Processing for the command export/import command ends when an  
authentication error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0727E  
Export/import command: Preview processing terminated abnormally - internal  
error.  
Explanation: Processing for the command export/import command in preview  
mode ends when an internal error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0728E  
Export/import command: Processing terminated abnormally - internal error.  
Explanation: Processing for the command export/import command ends when an  
internal error is encountered in the server.  
System Action: Export/import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0729E  
Import command: Syntax error from command \’server command\’.  
Explanation: During processing of the command import command, an internal  
syntax error is encountered in the server.  
Tivoli Storage Manager Messages  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Import processing continues, but the indicated command will have  
no effect.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. After import processing is complete, it may be  
necessary to issue additional commands manually to obtain the necessary  
definitions.  
ANR0730E  
ANR0731E  
ANR0732E  
Import command: Internal error from command \’server command\’.  
Explanation: Processing for the command import command ends when an internal  
command error is encountered in the server.  
System Action: Import processing ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Import command: Invalid value for COMPRESSION parameter in exported  
data for node node name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the COMPRESSION parameter for node node name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing COMPRESSION value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct COMPRESSION value is used for this node.  
Import command: Invalid value for ARCHDELETE parameter in exported data  
for node node name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the ARCHDELETE parameter for node node name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing ARCHDELETE value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct ARCHDELETE value is used for this node.  
112  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0733E  
ANR0734E  
ANR0735E  
ANR0736E  
Import command: Invalid value for BACKDELETE parameter in exported data  
for node node name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the BACKDELETE parameter for node node name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing BACKDELETE value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct BACKDELETE value is used for this node.  
Import command: Invalid value for COMPRESSION parameter in exported  
data - node node name registered with default COMPRESSION value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the COMPRESSION parameter for node node name.  
System Action: Processing of the command continues, by using the default  
COMPRESSION value for this node.  
User Response: Verify that the correct COMPRESSION value has been used for  
this node. Update this value, if necessary.  
Import command: Invalid value for ARCHDELETE parameter in exported data  
- node node name registered with default ARCHDELETE value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the ARCHDELETE parameter for node node name.  
System Action: Processing of the command continues, by using the default  
ARCHDELETE value for this node.  
User Response: Verify that the correct ARCHDELETE value has been used for  
this node. Update this value, if necessary.  
Import command: Invalid value for BACKDELETE parameter in exported data  
- node node name registered with default BACKDELETE value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the BACKDELETE parameter for node node name.  
System Action: Processing of the command continues, by using the default  
BACKDELETE value for this node.  
User Response: Verify that the correct BACKDELETE value has been used for  
this node. Update this value, if necessary.  
Tivoli Storage Manager Messages  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0737E  
ANR0738E  
ANR0739E  
ANR0740E  
Import command: Invalid value for COMPRESSION parameter in exported  
data - existing COMPRESSION value for node node name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the COMPRESSION parameter for node node name.  
System Action: Processing of the command continues, by using the existing  
COMPRESSION value for this node.  
User Response: Verify that the correct COMPRESSION value has been used for  
this node. Update this value, if necessary.  
Import command: Invalid value for ARCHDELETE parameter in exported data  
- existing ARCHDELETE value for node node name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the ARCHDELETE parameter for node node name.  
System Action: Processing of the command continues, by using the existing  
ARCHDELETE value for this node.  
User Response: Verify that the correct ARCHDELETE value has been used for  
this node. Update this value, if necessary.  
Import command: Invalid value for BACKDELETE parameter in exported data  
- existing BACKDELETE value for node node name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the BACKDELETE parameter for node node name.  
System Action: Processing of the command continues, by using the existing  
BACKDELETE value for this node.  
User Response: Verify that the correct BACKDELETE value has been used for  
this node. Update this value, if necessary.  
Import command: Invalid value for TYPE parameter in exported data for copy  
group copy group name in domain domain name, set policy set name,  
management class management class name - backup is assumed.  
Explanation: During processing of command import command, an invalid value is  
encountered for the TYPE parameter for copy group copy group, in policy domain  
domain name, policy set policy set name, management class management class  
name.  
System Action: Processing of the command continues. Based upon other copy  
group parameters, a copy group type of backup is assigned.  
114  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Verify that the assigned TYPE value of backup for this copy  
group is correct.  
ANR0741E  
ANR0742E  
ANR0743E  
Import command: Invalid value for TYPE parameter in exported data for copy  
group copy group name in domain domain name, set policy set name,  
management class management class name - archive is assumed.  
Explanation: During processing of command import command, an invalid value is  
encountered for the TYPE parameter for copy group copy group, in policy domain  
domain name, policy set policy set name, management class management class  
name.  
System Action: Processing of the command continues. Based upon other copy  
group parameters, a copy group type of archive is assigned.  
User Response: Verify that the assigned TYPE value of archive for this copy  
group is correct.  
Import command: Invalid value for TYPE parameter in exported data for copy  
group copy group name in domain domain name, set policy set name,  
management class management class name - this copy group will not be  
imported.  
Explanation: During processing of command import command, an invalid value is  
encountered for the TYPE parameter for copy group copy group, in policy domain  
domain name, policy set policy set name, management class management class  
name.  
System Action: Processing of the command continues. However, this copy group  
is not imported because a TYPE value cannot be assigned.  
User Response: Manually define this copy group, if necessary.  
Import command: Invalid value for MODE parameter in exported data for  
archive copy group copy group name in domain domain name, set policy set  
name, management class management class name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the MODE parameter for archive copy group copy group  
name, in policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing MODE value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct MODE value is used for this archive copy group.  
Tivoli Storage Manager Messages  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0744E  
ANR0745E  
ANR0746E  
Import command: Invalid value for MODE parameter in exported data for  
backup copy group copy group name in domain domain name, set policy set  
name, management class management class name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the MODE parameter for backup copy group copy group  
name, in policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing MODE value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct MODE value is used for this backup copy group.  
Import command: Invalid value for SERIALIZATION parameter in exported  
data for archive copy group copy group name in domain domain name, set policy  
set name, management class management class name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the SERIALIZATION parameter for archive copy group  
copy group name, in policy domain domain name, policy set policy set name,  
management class management class name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing SERIALIZATION value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct SERIALIZATION value is used for this archive copy group.  
Import command: Invalid value for SERIALIZATION parameter in exported  
data for backup copy group copy group name in domain domain name, set policy  
set name, management class management class name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the SERIALIZATION parameter for backup copy group  
copy group name, in policy domain domain name, policy set policy set name,  
management class management class name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing SERIALIZATION value is used.  
User Response: None. If the data is imported with a later command, verify that  
the correct SERIALIZATION value is used for this backup copy group.  
116  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0747E  
ANR0748E  
ANR0749E  
Import command: Invalid value for MODE parameter in exported data - archive  
copy group copy group name in domain domain name, set policy set name,  
management class management class name defined with default MODE value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the MODE parameter for archive copy group copy group name, in  
policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the default MODE  
value for this archive copy group.  
User Response: Verify that the correct MODE value has been used for this copy  
group. Update this value, if necessary.  
Import command: Invalid value for MODE parameter in exported data - backup  
copy group copy group name in domain domain name, set policy set name,  
management class management class name defined with default MODE value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the MODE parameter for backup copy group copy group name, in  
policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the default MODE  
value for this backup copy group.  
User Response: Verify that the correct MODE value has been used for this copy  
group. Update this value, if necessary.  
Import command: Invalid value for SERIALIZATION parameter in exported  
data - archive copy group copy group name in domain domain name, set policy  
set name, management class management class name defined with default  
SERIALIZATION value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the SERIALIZATION parameter for archive copy group copy group  
name, in policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the default  
SERIALIZATION value for this archive copy group.  
User Response: Verify that the correct SERIALIZATION value has been used for  
this copy group. Update this value, if necessary.  
Tivoli Storage Manager Messages  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0750E  
ANR0751E  
ANR0752E  
Import command: Invalid value for SERIALIZATION parameter in exported  
data - backup copy group copy group name in domain domain name, set policy  
set name, management class management class name defined with default  
SERIALIZATION value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the SERIALIZATION parameter for backup copy group copy group  
name, in policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the default  
SERIALIZATION value for this backup copy group.  
User Response: Verify that the correct SERIALIZATION value has been used for  
this copy group. Update this value, if necessary.  
Import command: Invalid value for MODE parameter in exported data -  
existing MODE value for archive copy group copy group name in domain  
domain name, set policy set name, management class management class name was  
not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the MODE parameter for archive copy group copy group name, in  
policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the existing  
MODE value for this archive copy group.  
User Response: Verify that the correct MODE value has been used for this copy  
group. Update this value, if necessary.  
Import command: Invalid value for MODE parameter in exported data -  
existing MODE value for backup copy group copy group name in domain  
domain name, set policy set name, management class management class name was  
not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the MODE parameter for backup copy group copy group name, in  
policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the existing  
MODE value for this backup copy group.  
User Response: Verify that the correct MODE value has been used for this copy  
group. Update this value, if necessary.  
118  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0753E  
ANR0754E  
ANR0755E  
Import command: Invalid value for SERIALIZATION parameter in exported  
data - existing SERIALIZATION value for archive copy group copy group name  
in domain domain name, set policy set name, management class management class  
name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the SERIALIZATION parameter for archive copy group copy group  
name, in policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the existing  
SERIALIZATION value for this archive copy group.  
User Response: Verify that the correct SERIALIZATION value has been used for  
this copy group. Update this value, if necessary.  
Import command: Invalid value for SERIALIZATION parameter in exported  
data - existing SERIALIZATION value for backup copy group copy group name  
in domain domain name, set policy set name, management class management class  
name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the SERIALIZATION parameter for backup copy group copy group  
name, in policy domain domain name, policy set policy set name, management class  
management class name.  
System Action: Processing of the command continues, by using the existing  
SERIALIZATION value for this backup copy group.  
User Response: Verify that the correct SERIALIZATION value has been used for  
this copy group. Update this value, if necessary.  
Import command: Invalid value for ACTION parameter in exported data for  
schedule schedule name in domain domain name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the ACTION parameter for schedule schedule name in  
policy domain domain name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing ACTION value is used.  
User Response: If the data is imported with a later command, verify that the  
correct ACTION value is used for this schedule.  
Tivoli Storage Manager Messages  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0756E  
Import command: Invalid value for DURUNITS or PERUNITS parameter in  
exported data for schedule schedule name in domain domain name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the DURUNITS or PERUNITS parameter for schedule  
schedule name in policy domain domain name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing values are used for DURATION,  
DURUNITS, PERIOD, and PERUNITS.  
User Response: If the data is imported with a later command, verify that the  
correct values for DURATION, DURUNITS, PERIOD, and PERUNITS are used for  
this schedule.  
ANR0757E  
Import command: Invalid value for DAYOFWEEK parameter in exported data  
for schedule schedule name in domain domain name.  
Explanation: During preview processing of command import command, an invalid  
value is encountered for the DAYOFWEEK parameter for schedule schedule name  
in policy domain domain name.  
System Action: Processing of the command continues. If a later command causes  
the data to be imported, the default or existing DAYOFWEEK value is used.  
User Response: If the data is imported with a later command, verify that the  
correct DAYOFWEEK value is used for this schedule.  
ANR0758E  
Import command: Invalid value for ACTION parameter in exported data -  
schedule schedule name in domain domain name defined with default ACTION  
value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the ACTION parameter for schedule schedule name in policy  
domain domain name.  
System Action: Processing of the command continues, by using the default  
ACTION value for this schedule.  
User Response: Verify that the correct ACTION value has been used for this  
schedule. Update this value, if necessary.  
120  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0759E  
ANR0760E  
ANR0761E  
Import command: Invalid value for DURUNITS or PERUNITS parameter in  
exported data - schedule schedule name in domain domain name defined with  
default values for DURATION, DURUNITS, PERIOD, and PERUNITS.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DURUNITS or PERUNITS parameter for schedule schedule  
name in policy domain domain name.  
System Action: Processing of the command continues, by using the default values  
for DURATION, DURUNITS, PERIOD, and PERUNITS.  
User Response: Verify that the correct values have been used for DURATION,  
DURUNITS, PERIOD, and PERUNITS. Update these values, if necessary.  
Import command: Invalid value for DAYOFWEEK parameter in exported data -  
schedule schedule name in domain domain name defined with default  
DAYOFWEEK value.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DAYOFWEEK parameter for schedule schedule name in policy  
domain domain name.  
System Action: Processing of the command continues, by using the default  
DAYOFWEEK value for this schedule.  
User Response: Verify that the correct DAYOFWEEK value has been used for this  
schedule. Update this value, if necessary.  
Import command: Invalid value for ACTION parameter in exported data -  
existing ACTION value for schedule schedule name in domain domain name was  
not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the ACTION parameter for schedule schedule name in policy  
domain domain name.  
System Action: Processing of the command continues, by using the existing  
ACTION value for this schedule.  
User Response: Verify that the correct ACTION value has been used for this  
schedule. Update this value, if necessary.  
Tivoli Storage Manager Messages  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0762E  
Import command: Invalid value for DURUNITS or PERUNITS parameter in  
exported data - existing values for DURATION, DURUNITS PERIOD, and  
PERUNITS for schedule schedule name in domain domain name were not  
updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DURUNITS or PERUNITS parameter for schedule schedule  
name in policy domain domain name.  
System Action: Processing of the command continues, by using the existing values  
for DURATION, DURUNITS, PERIOD, and PERUNITS.  
User Response: Verify that the correct values have been used for DURATION,  
DURUNITS, PERIOD, and PERUNITS. Update these values, if necessary.  
ANR0763E  
Import command: Invalid value for DAYOFWEEK parameter in exported data -  
existing DAYOFWEEK value for schedule schedule name in domain domain  
name was not updated.  
Explanation: During processing of command import command, an invalid value is  
encountered for the DAYOFWEEK parameter for schedule schedule name in policy  
domain domain name.  
System Action: Processing of the command continues, by using the existing  
DAYOFWEEK value for this schedule.  
User Response: Verify that the correct DAYOFWEEK value has been used for this  
schedule. Update this value, if necessary.  
ANR0764E  
Import command: Invalid lock status detected while importing node node name -  
this node will not be locked.  
Explanation: During processing of command import command, an invalid value is  
encountered for the lock status for node node name.  
System Action: Processing of the command continues, but the node is not locked.  
User Response: An administrator with the proper authorization must issue the  
LOCK NODE command, if necessary.  
ANR0765E  
Import command: Invalid lock status detected while importing administrator  
administrator name - this administrator will not be locked.  
Explanation: During processing of command import command, an invalid value is  
encountered for the lock status for administrator administrator name.  
System Action: Processing of the command continues, but the administrator is not  
locked.  
122  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: An administrator with the proper authorization must issue the  
LOCK ADMIN command, if necessary.  
ANR0766E  
Export command: Invalid value for TYPE parameter detected while exporting  
copy group copy group name in domain domain name, set policy set name,  
management class management class name - system will attempt to assign value  
during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the TYPE parameter for copy group copy group name, in domain  
domain name, policy set policy set name, management class management class  
name.  
System Action: Export processing continues, but the exported data contains an  
unknown TYPE value for this copy group. If this data is imported, the system  
attempts to assign a TYPE value based upon values for other copy group  
parameters.  
User Response: Delete and define this copy group to eliminate the invalid data,  
and then restart the export command. Alternatively, use the export data with the  
unknown value, and the system will attempt to assign a TYPE during import  
processing.  
ANR0767E  
Export command: Invalid value for MODE parameter detected while exporting  
copy group copy group name in domain domain name, set policy set name,  
management class management class name - default or existing value is used  
during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the MODE parameter for copy group copy group name in domain  
domain name, policy set policy set name, management class management class  
name.  
System Action: Export processing continues, but the exported data contains an  
unknown MODE value for this copy group. If this data is imported, the default or  
existing MODE value is used.  
User Response: Update the MODE value for this copy group and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the MODE value after import processing has been performed.  
Tivoli Storage Manager Messages  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0768E  
Export command: Invalid value for SERIALIZATION parameter detected while  
exporting copy group copy group name in domain domain name, set policy set  
name, management class management class name - default or existing value is  
used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the SERIALIZATION parameter for copy group copy group name,  
in domain domain name, policy set policy set name, management class management  
class name.  
System Action: Export processing continues, but the exported data contains an  
unknown SERIALIZATION value for this copy group. If this data is imported, the  
default or existing SERIALIZATION value is used.  
User Response: Update the SERIALIZATION value for this copy group and  
restart the export command. Alternatively, use the export data with the unknown  
value, and check and update the SERIALIZATION value after import processing  
has been performed.  
ANR0769E  
Export command: Invalid value for ACTION parameter detected while  
exporting schedule schedule name in domain domain name - default or existing  
value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the ACTION parameter for schedule schedule name in domain  
domain name.  
System Action: Export processing continues, but the exported data will contain an  
unknown ACTION value for this schedule. If this data is imported, the default or  
existing ACTION value is used.  
User Response: Update the ACTION value for this schedule and restart the export  
command. Alternatively, use the export data with the unknown value, and check and  
update the ACTION value after import processing has been performed.  
ANR0770E  
Export command: Invalid value for DURUNITS parameter detected while  
exporting schedule schedule name in domain domain name - default or existing  
value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the DURUNITS parameter for schedule schedule name in domain  
domain name.  
System Action: Export processing continues, but the exported data contains an  
unknown DURUNITS value for this schedule. If this data is imported, the default or  
existing DURUNITS value is used.  
124  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Update the DURUNITS value for this schedule and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the DURUNITS value after import processing has been  
performed.  
ANR0771E  
Export command: Invalid value for PERUNITS parameter detected while  
exporting schedule schedule name in domain domain name - default or existing  
value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the PERUNITS parameter for schedule schedule name in domain  
domain name.  
System Action: Export processing continues, but the exported data will contain an  
unknown PERUNITS value for this schedule. If this data is imported, the default or  
existing PERUNITS value is used.  
User Response: Update the PERUNITS value for this schedule and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the PERUNITS value after import processing has been performed.  
ANR0772E  
Export command: Invalid value for DAYOFWEEK parameter detected while  
exporting schedule schedule name in domain domain name - default or existing  
value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the DAYOFWEEK parameter for schedule schedule name in  
domain domain name.  
System Action: Export processing continues, but the exported data contains an  
unknown DAYOFWEEK value for this schedule. If this data is imported, the default  
or existing DAYOFWEEK value is used.  
User Response: Update the DAYOFWEEK value for this schedule and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the DAYOFWEEK value after import processing has been  
performed.  
ANR0773E  
Export command: Invalid lock status detected while exporting administrator  
administrator name - this administrator will not be locked during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the lock status for administrator administrator name.  
System Action: Export processing continues, but the exported data contains an  
unknown lock status for this administrator. If this data is imported, the administrator  
will not be locked.  
Tivoli Storage Manager Messages  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: An administrator with the proper authorization must issue the  
LOCK NODE or UNLOCK NODE command to achieve the desired lock status, and  
then restart the export command. Alternatively, use the export data with the  
unknown status, and issue a LOCK ADMIN or UNLOCK ADMIN command after  
import processing has been performed.  
ANR0774E  
ANR0775E  
ANR0776E  
Export command: Invalid value for COMPRESSION parameter detected while  
exporting node node name - default or existing value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the COMPRESSION parameter for node node name.  
System Action: Export processing continues, but the exported data contains an  
unknown COMPRESSION value for this node. If this data is imported, the default  
or existing COMPRESSION value is used.  
User Response: Update the COMPRESSION parameter for this node and restart  
the export command. Alternatively, use the export data with the unknown value, and  
check and update the COMPRESSION value after import processing has been  
performed.  
Export command: Invalid lock status detected while exporting node node name -  
this node will not be locked during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the lock status for node node name.  
System Action: Export processing continues, but the exported data contains an  
unknown lock status for this node. If this data is imported, the node will not be  
locked.  
User Response: Lock or unlock the node to achieve the desired lock status, and  
then restart the export command. Alternatively, use the export data with the  
unknown status, and lock or unlock the node after import processing has been  
performed.  
Export command: Invalid value for ARCHDELETE parameter detected while  
exporting node node name - default or existing value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the ARCHDELETE parameter for node node name.  
System Action: Export processing continues, but the exported data contains an  
unknown ARCHDELETE value for this node. If this data is imported, the default or  
existing ARCHDELETE value is used.  
126  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Update the ARCHDELETE parameter for this node and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the ARCHDELETE value after import processing has been  
performed.  
ANR0777E  
Export command: Invalid value for BACKDELETE parameter detected while  
exporting node node - default or existing value is used during import.  
Explanation: During processing of command export command, an invalid value is  
encountered for the BACKDELETE parameter for node node name.  
System Action: Export processing continues, but the exported data contains an  
unknown BACKDELETE value for this node. If this data is imported, the default or  
existing BACKDELETE value is used.  
User Response: Update the BACKDELETE parameter for this node and restart the  
export command. Alternatively, use the export data with the unknown value, and  
check and update the BACKDELETE value after import processing has been  
performed.  
ANR0778E  
ANR0779E  
ANR0780E  
Command: Error encountered in accessing data storage - device class device  
class name is not defined.  
Explanation: During command command processing, an error occurred because  
the specified device class is not defined.  
System Action: The command command is ended and server operation continues.  
User Response: Make sure the specified device class is defined.  
Command: Error encountered in accessing data storage - disk volume specified.  
Explanation: During command command processing, an error occurred because a  
specified volume is a disk volume rather than a tape volume.  
System Action: The command command is ended and server operation continues.  
User Response: Make sure that all volumes specified for the command command  
are tape volumes.  
Export/import command: Process aborted - a server communications session  
could not be established.  
Explanation: The server export/import process encounters an internal error in  
establishing an intermemory communications session with other server components.  
System Action: The export or import process ends and server operation continues.  
Tivoli Storage Manager Messages  
127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”. If the error is not resolved, contact your service  
representative.  
ANR0781E  
Export/import command: Process aborted - server sign on failed.  
Explanation: The server export/import process encounters an internal error in  
establishing an intermemory communications session with other server components.  
System Action: The export or import process ends and server operation continues.  
User Response: Contact your service representative.  
ANR0782E  
Export/import command: Process aborted - a server data storage session could  
not be established (rc return code).  
Explanation: The server export/import process encounters an internal error in  
establishing a session with the data storage services.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0783E  
Export/import command: Process aborted - a server data storage Export/Import  
stream could not be established (rc return code).  
Explanation: The server export/import process encounters an internal error in  
establishing a session with the data storage services.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0784E  
Export/import command: Process aborted - internal error detected with the  
Export/Import level: level number.  
Explanation: The server export/import process encounters an internal error in  
evaluating the export/import level (SERVER, NODE, ADMIN, POLICY).  
System Action: The export or import process ends and server operation continues.  
128  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0785E  
ANR0786E  
ANR0787E  
Import command: Invalid record type xrecord type read from export data.  
Explanation: The server export/import process encounters an internal error in  
reading data from the export media. An invalid record type of record type is  
encountered during the read operation.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Import command: Invalid export version version number in exported data.  
Explanation: The server import process encounters an internal error in reading  
data from the export media. An invalid export version number (version number) is  
encountered during the read operation.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Import command: Import of file space filespace name in node node name aborted  
by server (abort reason).  
Explanation: The server import process encounters an internal error in importing  
file space filespace name for client node node name. The reason code abort reason  
is encountered.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Tivoli Storage Manager Messages  
129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0788E  
Import command: Error error code during import of data storage data.  
Explanation: The server import process encounters an internal data storage error.  
The error code error code is encountered.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0789E  
Import command: Failure in normalizing transaction identifier for sending to the  
server.  
Explanation: The server import process encounters an internal database transaction  
error in importing information into the server database.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0790E  
Import command: Error in absorbing data records.  
Explanation: The server import process encounters an internal error in importing  
information into the server database.  
System Action: The export or import process ends and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0791E  
Export/import command: Protocol error - verb verb typewith length verb length  
received, expected expected type.  
Explanation: The server export or import process encounters an internal protocol  
error in exporting information from or importing information into the server  
database. The verb verb type is encountered with a length of verb length when a  
verb type of expected type was expected.  
System Action: The export or import process ends and server operation continues.  
130  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0792E  
Import command: Invalid copy type encountered in an imported file space  
authorization rule for node node name, file space filespace name - a type of  
BACKUP will be assumed.  
Explanation: During import processing for command import command, an invalid  
copy type is encountered for an authorization rule that grants access for file space  
filespace name on node node name. Authorization rules typically specify copy types  
of backup or archive, depending on whether backup file access or archive file access  
is granted by the file space owner to other users. Because the imported information  
for the rule is ambiguous, the server assumes that the rule is for backup data.  
System Action: The import process continues.  
User Response: The user for node node name should query the access rules for  
the specified node name after the import process has completed, and correct or  
delete any access rules that are in error or not needed.  
ANR0793E  
Export/import command: Preview processing terminated abnormally - error  
accessing data storage.  
Explanation: The server encountered an internal error in accessing data storage  
while executing an import or export preview operation.  
System Action: The export or import operation is ended and server operation  
continues.  
User Response: Use the QUERY ACTLOG command to examine messages prior  
to this error to determine the cause of the data storage failure. If you find and  
resolve the error, retry the export or import operation. If you cannot find the error,  
contact your service representative for assistance in resolving the problem.  
ANR0794E  
Export/import command: Processing terminated abnormally - error accessing  
data storage.  
Explanation: The server encountered an internal error in accessing data storage  
while executing an import or export operation.  
System Action: The export or import operation is ended and server operation  
continues.  
User Response: Use the QUERY ACTLOG command to examine messages prior  
to this error to determine the cause of the data storage failure. If you find and  
Tivoli Storage Manager Messages  
131  
Download from Www.Somanuals.com. All Manuals Search And Download.  
resolve the error, retry the export or import operation. If you cannot find the error,  
contact your service representative for assistance in resolving the problem.  
ANR0795E  
Command: Error encountered in accessing data storage - invalid volume name  
specified.  
Explanation: The server encounters an error in accessing data storage while  
processing command command. The error occurred because an attempt has been  
made to access a volume with an invalid name.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Issue the command with a valid volume name.  
ANR0796E  
Command: Error encountered in accessing data storage - insufficient number of  
mount points available for removable media.  
Explanation: During command command processing, the server cannot allocate  
sufficient mount points.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: If necessary, make more mount points available.  
ANR0797E  
Command: Error encountered in accessing data storage - required volume was  
not mounted.  
Explanation: During command command processing, a required volume cannot be  
mounted. The mount request may have been canceled.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Issue the command again and make sure the necessary volumes  
are accessible.  
ANR0798E  
Import command: Error encountered in accessing data storage - volume cannot  
be used.  
Explanation: During import processing, a volume has been mounted but cannot be  
used.  
System Action: The import operation is ended and server operation continues.  
User Response: Query the activity log for messages preceding this one that give  
additional information. Make sure a usable volume is specified and mounted.  
132  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0799E  
Command: Error encountered in accessing data storage - volume already in use.  
Explanation: During command command processing, a volume cannot be used  
because it is already defined in a storage pool, or has been previously used by an  
export, database dump, or database backup operation (as recorded in the volume  
history) or is in use by another process.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Specify a volume that is not in use or defined in a storage pool,  
and that has not been previously used for an export, database dump, or database  
backup operation as recorded in the server volume history information. Use the  
QUERY VOLUME command to display the names of volumes that are defined to  
server storage pools. Use the QUERY VOLHISTORY command to display the  
names of volumes that have been used for export, database dump, or database  
backup operations.  
ANR0800I  
Command: command for node node name started as process process ID.  
Explanation: A file space deletion process has started to delete one or more file  
spaces for the specified node. The process is assigned the ID specified in the  
message.  
System Action: The server starts a background process to perform the operation in  
response to the DELETE FILESPACE command entered by an administrator.  
User Response: To obtain status on the file space deletion process, issue the  
QUERY PROCESS command. The process may be canceled with the CANCEL  
PROCESS command.  
ANR0801I  
Delete Filespace filespace name for node node name started as process process  
ID.  
Explanation: The specified client node has started a file space deletion process  
(on the server) to delete one or more file spaces. The process has been assigned the  
ID specified in the message.  
System Action: The server starts a background process to perform the operation in  
response to a request from the client node.  
User Response: To obtain status on the file space deletion process, issue the  
QUERY PROCESS command. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
Tivoli Storage Manager Messages  
133  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0802I  
ANR0803I  
ANR0804I  
Delete Filespace filespace name (backup/archive data) for node node name  
started.  
Explanation: A background server process has started (on the server) to delete the  
specified file space belonging to the node indicated. If a file space name is not  
included in the message, all file spaces belonging to the node are deleted.  
System Action: The background process deletes backup and archive objects for the  
specified file space while server operation continues.  
User Response: To obtain status on the file space deletion process, issue the  
QUERY PROCESS command. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
Delete Filespace filespace name (backup data) for node node name started.  
Explanation: A background server process has started (on the server) to delete  
backup objects in the specified file space belonging to the node indicated. If a file  
space name is not included in the message, then the backup objects for all file  
spaces that belong to the node are deleted.  
System Action: The background process deletes backup objects for the specified  
file space while server operation continues.  
User Response: To obtain status on the file space deletion process, issue the  
QUERY PROCESS command. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
Delete Filespace filespace name (archive data) for node node name started.  
Explanation: A background server process has started (on the server) to delete  
archive objects in the specified file space belonging to the node indicated. If a file  
space name is not included in the message, then the archive objects for all file  
spaces that belong to the node are deleted.  
System Action: The background process deletes archive objects for the specified  
file space while server operation continues.  
User Response: To obtain status on the file space deletion process, issue the  
QUERY PROCESS command. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
134  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0805I  
Delete Filespace filespace name canceled for node node name: number of objects  
objects deleted.  
Explanation: A background server process that has been deleting file space data  
for the indicated node is canceled by the CANCEL PROCESS command. The  
number of objects deleted before the cancel ended the operation are reported in the  
message.  
System Action: The server process is ended and server operation continues.  
User Response: No action is required. An authorized administrator can issue the  
DELETE FILESPACE command to delete remaining objects in the file space.  
ANR0806I  
Delete Filespace filespace name complete for node node name: number of objects  
objects deleted.  
Explanation: A server process deleting file space data for the node specified has  
completed. The total number of objects deleted is reported in the message.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
ANR0811I  
Inventory client file expiration started as process process ID.  
Explanation: The server has started roll-off processing to remove expired client  
backup and archive file copies, based on the management class policy that is bound  
to the files. The copy group retention and version parameters for each file’s copy  
group are used by the server to determine if copies are to be deleted from the  
server. The expiration process was started as process number process ID, and may  
be queried or canceled with the QUERY PROCESS or CANCEL PROCESS  
commands, respectively.  
System Action: The expiration process is now cancellable. Server operation  
continues.  
User Response: None.  
ANR0812I  
Inventory file expiration process process ID completed: examined number of  
objects objects, deleting number of backup objects backup objects, number of  
archive objects archive objects, number of DB backup volumes DB backup  
volumes, and number of recovery plan files recovery plan files. error count errors  
were encountered.  
Explanation: Server roll-off processing has completed. The number of client  
objects examined and deleted, based on management class policy, are displayed in  
the message. A total error count is also displayed. The number of DB backup  
volumes deleted is based on the value specified on the SET  
Tivoli Storage Manager Messages  
135  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRMDBBACKUPEXPIREDAYS. The number of recovery plan files deleted is  
based on the value specified on the SET DRMRPFEXPIREDAYS. Server roll-off  
processing deletes the DB backup volumes and recovery plan files only if DRM is  
licensed on the server and the volumes or plan files are created on the server to  
server virtual volumes.  
System Action: The roll-off process is ended and server operation continues.  
User Response: If the error count is not equal to 0, examine messages that may  
have been issued in the activity log to determine the cause for the errors.  
ANR0813I  
Inventory file expiration process process ID canceled prior to completion:  
examined number of objects objects, deleting number of backup objects backup  
objects, number of archive objects archive objects, number of DB backup volumes  
DB backup volumes, and number of recovery plan files recovery plan files. error  
count errors were encountered.  
Explanation: The inventory file expiration process was canceled by an  
administrator. The number of objects examined and deleted prior to the cancelation  
are reported. A total error count is also displayed.  
System Action: The server ends the file expiration process.  
User Response: None.  
ANR0814I  
Expiration retry retry number of maximum retries in number of seconds seconds.  
Explanation: Server roll-off processing has encountered an error in attempting to  
remove expired client file copies from the server database. The operation will be  
tried again in the number of seconds indicated.  
System Action: The server waits for the number of seconds indicated and retries  
the file expiration operation.  
User Response: Expiration retry processing occurs when the server database is  
full, the log is full, or sufficient server memory is not available to continue  
processing. Use the QUERY ACTLOG command to look for messages issued prior  
to this one that indicate the type of error encountered. If the server is out of  
database space, issue the DEFINE DBVOLUME and EXTEND DB commands to  
add volumes to the server database and extend the database size. If the server is out  
of log space, issue the DEFINE LOGVOLUME and EXTEND LOG commands to  
add volumes to the server log and extend the log size. If the server is low on  
memory, allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
136  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0815I  
Expiration retry in progress.  
Explanation: The server is retrying an operation during client file roll-off  
processing. Expiration retry processing occurs when the server database is full, the  
log is full, or sufficient server memory is not available to continue processing.  
System Action: The roll-off operation is retried.  
User Response: Use the QUERY ACTLOG command to look for messages issued  
prior to this one that indicate the type of error encountered. If the server is out of  
database space, issue the DEFINE DBVOLUME and EXTEND DB commands to  
add volumes to the server database and extend the database size. If the server is out  
of log space, issue the DEFINE LOGVOLUME and EXTEND LOG commands to  
add volumes to the server log and extend the log size. If the server is low on  
memory, allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0816I  
Expiration retry was successful.  
Explanation: In accordance with management class policy, server roll-off  
processing has been successful in retrying a client file expiration.  
System Action: Server roll-off processing continues.  
User Response: None.  
ANR0818I  
Waiting to retry expiration because of insufficient resources.  
Explanation: The server inventory expiration process is waiting to retry expiration  
processing that failed because of insufficient memory, database, or log resources on  
the server.  
System Action: Server operation continues. The expiration processing is  
reattempted automatically.  
User Response: Use the QUERY ACTLOG command to examine messages issued  
prior to this one, which indicated the resource that is not available to the expiration  
process. Correct the shortage.  
ANR0819I  
Cancel in progress  
Explanation: This message is displayed in response to a QUERY PROCESS  
command, and indicates that an inventory expiration process has been canceled. The  
process will end shortly.  
System Action: The expiration process terminates and server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
137  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0820I  
Sorting information for number objects has been deleted.  
Explanation: A background server process has deleted sorting information for  
number files from the server database. This process is started during initialization to  
remove any sorting information which is left over from previous export operations.  
System Action: The actual backup or archive objects were not deleted, but only  
information used to sort these objects during the previous export operation.  
User Response: None.  
ANR0821E  
ANR0822I  
Filespace identifier fsId is not valid.  
Explanation: The identifier assigned for a filespace is out of range.  
System Action: The filespace is not added.  
User Response: Contact your service representative.  
command: Filespace filespace name successfully renamed to new filespace name  
for node node name.  
Explanation: The filespace specified was renamed to the new name specified for  
the node. This message is displayed in response to successful completion of the  
RENAME FILESPACE command.  
System Action: The system renames the filespace for the node as indicated  
User Response: None.  
ANR0823E  
command: Filespace filespace name cannot be renamed to new filespace name, a  
filespace with this name already exists for node node name.  
Explanation: The filespace name specified as a target name for the command was  
found to already exist for the node specified. The command fails.  
System Action: Server operation continues, the command fails.  
User Response: Reissue the command with a different target filespace name  
ANR0824I  
Delete Filespace filespace name (space-managed data) for node node name  
started.  
Explanation: A background server process has started (on the server) to delete  
space-managed objects in the specified file space belonging to the node indicated. If  
a file space name is not included in the message, then the space-managed objects  
for all file spaces that belong to the node are deleted.  
System Action: The background process deletes space-managed objects for the  
specified file space while server operation continues.  
138  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: To obtain status on the file space deletion process, issue the  
QUERY PROCESS command. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
ANR0826I  
DELETE FILESPACE filespace name for node node name encountered a  
transaction failure.  
Explanation: A background server process that has been deleting file space data  
for the indicated node encountered a transaction failure.  
System Action: The server process is retried if the maximum number of retry  
attempts have not been exceeded.  
User Response: Transaction failure usually indicates that a database deadlock was  
detected during filespace deletion. These deadlock conditions are sometimes  
encountered when multiple filespace deletion processes are running at the same  
time. No action is required unless the DELETE FILESPACE terminates without  
completing the deletion process (see message ANR0828).  
ANR0827I  
DELETE FILESPACE filespace name will be retried for node node name.  
Explanation: A filespace deletion process for the node indicated is being retried  
because an error was encountered.  
System Action: The server process is retried.  
User Response: None.  
ANR0828W  
DELETE FILESPACE filespace name for node node name terminated before  
completion due to transaction failure: number of objects objects deleted.  
Explanation: A background server process that has been deleting file space data  
for the indicated node is terminated prematurely because of transaction failure. The  
number of objects deleted before the operation ended are reported in the message.  
System Action: The server process is ended and server operation continues.  
User Response: Termination of this process because of transaction failure usually  
indicates that a database deadlock was detected during filespace deletion. These  
deadlock conditions are sometimes encountered when multiple filespace deletion  
processes are running at the same time. The command should be started again when  
fewer filespace deletion processes are active. An authorized administrator can issue  
the DELETE FILESPACE command to delete remaining files in the file space(s).  
Tivoli Storage Manager Messages  
139  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0829E  
Command: Invalid combination of TYPE and DATA parameters.  
Explanation: The specified command has been issued with an invalid combination  
of the TYPE and DATA parameters. DATA=IMAGES can only be specified if  
TYPE=ANY or TYPE=BACKUP.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid combination of  
parameters.  
ANR0830W  
Management class class name in domain domain name used by node node name  
in file space filespace name is no longer active, or no longer has a BACKUP  
copy group: DEFAULT management class attributes will be used for expiration.  
Explanation: During policy roll-off processing, the server has found a client file  
copy whose management class or backup copy group no longer exists.  
System Action: The server obtains the DEFAULT management class for the  
specified domain and uses its backup copy group version and retention parameters  
to determine if file copies need to be expired.  
User Response: No action is required. A policy administrator with authority over  
the specified domain may use the DEFINE COPYGROUP, DEFINE MGMTCLASS,  
and ACTIVATE POLICY commands to define and activate a policy set that contains  
definitions for the missing management class or copy group.  
ANR0831W  
The DEFAULT management class class name in domain domain name does not  
have a BACKUP copy group: GRACE PERIOD will be used for expiration.  
Explanation: During policy roll-off processing, the server found a client file copy  
whose management class or backup copy group no longer exists. The DEFAULT  
management class for the indicated policy domain does not contain a backup copy  
group; therefore, the server uses the GRACE PERIOD retention value defined for  
the specified policy domain to determine if client file copies need to be expired and  
removed from the server database.  
System Action: The server obtains the GRACE PERIOD retention values for the  
specified domain and then determines if backup file copies need to be expired.  
User Response: No action is required. A policy administrator with authority over  
the specified domain may use the DEFINE COPYGROUP, DEFINE MGMTCLASS,  
and ACTIVATE POLICY commands to define and activate a policy set that contains  
definitions for the missing management class or backup copy group.  
140  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0832W  
Management class class name in domain domain name used by node node name  
in filespace filespace name is no longer active, or no longer has an ARCHIVE  
copy group: DEFAULT management class attributes will be used for expiration.  
Explanation: During policy roll-off processing, the server found a client file copy  
whose management class or archive copy group no longer exists.  
System Action: The server obtains the DEFAULT management class for the  
specified domain and uses its archive copy group retention parameter to determine if  
file copies need to be expired.  
User Response: No action is required. A policy administrator with authority over  
the specified domain may use the DEFINE COPYGROUP, DEFINE MGMTCLASS,  
and ACTIVATE POLICY commands to define and activate a policy set that contains  
definitions for the missing management class or copy group.  
ANR0833W  
The DEFAULT management class class name in domain domain name does not  
have an ARCHIVE copy group: GRACE PERIOD will be used for expiration.  
Explanation: During policy roll-off processing, the server found a client file copy  
whose management class or archive copy group no longer exists. The DEFAULT  
management class for the indicated policy domain does not contain an archive copy  
group; therefore, the server uses the GRACE PERIOD retention value defined for  
the specified policy domain to determine if client file copies need to be expired and  
removed from the server database.  
System Action: The server obtains the GRACE PERIOD retention values for the  
specified domain and then determines if archive file copies need to be expired.  
User Response: No action is required. A policy administrator with authority over  
the specified domain may use the DEFINE COPYGROUP, DEFINE MGMTCLASS,  
and ACTIVATE POLICYSET commands to define and activate a policy set that  
contains definitions for the missing management class or backup copy group.  
ANR0834W  
Inventory client file expiration cannot start because of insufficient memory -  
will retry in number of seconds seconds.  
Explanation: The server inventory expiration process is pausing to retry an  
operation that failed because sufficient memory is not available on the server.  
System Action: Server operation continues; the expiration process will be retried  
after the stated delay.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
Tivoli Storage Manager Messages  
141  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0835W  
Management class class name in domain domain name is no longer active, or no  
longer has a BACKUP copy group, or no longer has an ARCHIVE copy group.  
DEFAULT management class used to delete number of backup files backup files  
and number of archive files archive files. Retention grace period used to delete  
number of backup files backup files and number of archive files archive files.  
Explanation: During policy roll-off processing, the server found a management  
class or backup copy group or archive copy group that no longer exists. When a  
management class or backup copy group no longer exists, the number of backup  
client file copies that have been deleted using the default management class or the  
retention grace period is displayed in the message. When a management class or  
archive copy group no longer exists, the number of archive client files that have  
been deleted using the default management class or the retention grace period is  
displayed in the message.  
System Action: The server obtains the DEFAULT management class for the  
specified domain and uses its backup copy group or archive copy group version and  
retention parameters to determine if file copies need to be expired. If, however, the  
needed backup copy group or archive copy group does not exist in the DEFAULT  
management class, the server will use the retention grace period for the domain.  
User Response: No action is required. This message is only issued when  
expiration processing has been started with the QUIET option to suppress detailed  
messages. Expiration processing can be started without the QUIET option to see the  
detailed messages which will indicate specific node and filespaces and will further  
distinguish between backup and archive copy groups. A policy administrator with  
authority over the specified domain may use the DEFINE COPYGROUP, DEFINE  
MGMTCLASS, and ACTIVATE POLICY commands to define and activate a policy  
set that contains definitions for the missing management class or copy group.  
ANR0836W  
No query restore processing session session id for node node name and filespace  
name failed to retrieve file high-level file namelow-level file name - file being  
skipped.  
Explanation: The no query restore processing for the session listed relating to the  
specified node name and filespace failed to retrieve the specified file. An error  
occurred while retrieving this file so it will be skipped.  
System Action: The no query restore operation continues.  
User Response: Determine the cause of the file retieve failure and correct it. After  
this situation is correct, the client can do a restore of the specific file that was  
skipped.  
142  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0837I  
The expire inventory running duration of number of minutes minutes has  
expired. The expire inventory process ends.  
Explanation: A TSM Administrator or schedule issued the command EXPIRE  
INVENTORY ... DURATION=xxx, where xxx is the number of minutes for the  
expire inventory process to run. That xxx number of minutes has been reached, so  
the expire inventory process ends.  
System Action: The expire inventory process ends.  
User Response: None.  
ANR0838I  
ANR0839E  
ANR0840I  
ANR0841I  
Command: Archive directory cleanup job Job ID started as background process  
process ID.  
Explanation: An archive directory cleanup job started under the indicated  
background server process with the indicated process identifier.  
System Action: Server processing continues.  
User Response: None.  
Command: There are no restartable jobs. Job Job ID not found.  
Explanation: A QUERY ARCHDIRCLEAN command was issued but no archive  
directory cleanup jobs were found. The jobid is 0 if a specific job id was specified  
on the Query command.  
System Action: Server processing continues.  
User Response: None.  
Command: Archive directory cleanup job Job ID started as foreground process  
process ID.  
Explanation: An archive directory cleanup job started under the indicated  
foreground server process with the indicator process identifier.  
System Action: Server processing continues.  
User Response: None.  
( Job ID ): Skipping node node ID; node being cleaned by job Other Job ID.  
Explanation: The indicated archive directory cleanup job is skipping the indicated  
node because a different archive directory cleanup job ( as specified ) is working on  
the same node.  
System Action: Server processing continues.  
Tivoli Storage Manager Messages  
143  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR0842I  
Command: ( Job ID ): Archive cleanup was cancelled - number of nodes nodes  
processed, last node was last node.  
Explanation: The indicated archive directory cleanup job was cancelled. Prior to  
cancellation, the indicated number of nodes were processed. The last processed node  
is also displayed.  
System Action: The archive cleanup operation ends. Server processing continues.  
User Response: The archive directory cleanup may be restarted by specifying the  
JOBID parameter on the CLEAN ARCHDIRectories command.  
ANR0843I  
Command: Archive directory cleanup job Job ID completed successfully number  
of nodes nodes were processed.  
Explanation: An archive directory cleanup job completed successfully. The job  
identifier and the number of nodes that were processed are displayed.  
System Action: The archive directory cleanup operation ends.  
User Response: None.  
ANR0844E  
Job ID: Skipping node node name - node not found.  
Explanation: The indicated nodename was not processed by the indicated archive  
directory cleanup job. The node was not found by the time the job got around to  
working on it.  
System Action: The node is skipped. Other nodes are processed.  
User Response: None.  
ANR0845I  
Job ID: Skipping node node name - is not a backup/archive node.  
Explanation: The indicated nodename was not processed by the indicated archive  
directory cleanup job. The node was not a backup/archive client node.  
System Action: The node is skipped. Other nodes are processed.  
User Response: None.  
ANR0846I  
Job ID: Deleted ( objIdHi.objIdHi ) for node ( Node name ) fsId( File Space Id hl(  
Dir Name Part 1 ) ll( Dir Name Part 2 ) descr( Dir Description ).  
Explanation: The indicated archive directory cleanup job deleted a duplicate  
directory entry. Information from the data base about the duplicate entry is  
144  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
displayed, including the two part object identifier, node name, file space identifier,  
two part directory name and the description from the archive information.  
System Action: The entry is deleted. Processing continues.  
User Response: None.  
ANR0847I  
Job ID: Found directory ( objIdHi.objIdHi ) for node ( Node name ) filespace(  
File Space hl( Dir Name Part 1 ) ll( Dir Name Part 2 ) descr( Dir Description ).  
Explanation: The indicated archive directory cleanup job found a duplicate  
directory entry. Information from the data base about the duplicate entry is  
displayed, including the two part object identifier, node name, file space name, two  
part directory name and the description from the archive information. The duplicate  
directory will be deleted if the FIX=YES parameter of the CLEAN ARCHDIR  
command is specified. Since FIX=NO was specified or defaulted, the duplicate  
directory is not removed.  
System Action: The entry is not deleted. Processing continues.  
User Response: None.  
ANR0848W  
Expiration failed to delete file type file file name for node node name and  
filespace filespace name - file will be skipped.  
Explanation: The expiration process was unable to delete the indicated file. The  
file will be skipped by expiration.  
System Action: The expiration process continues.  
User Response: Re-try expiration to determine if the cause of the deletion failure  
was an intermittent problem or if it is a permanent problem. If after a subsequent  
expiration attempt the file still is not deleted, please contact your service  
representative.  
ANR0849E  
Command: Not permitted for node Node Name - node of type SERVER.  
Explanation: The indicated DELETE FILESPACE process is not started because  
the node specified is of NODETYPE=SERVER. A DELETE FILESPACE may only  
be processed for nodes of this type with the TYPE=SERVER parameter specified.  
System Action: The DELETE FILESPACE command is ended and server  
processing continues.  
User Response: If this filespace must be deleted, Reissue the command with the  
TYPE parameter set to TYPE=SERVER. Please use caution when using the  
TYPE=SERVER parameter as this can impact the availability of data for the server  
that owns these files.  
Tivoli Storage Manager Messages  
145  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0850E  
Command: Cannot Start process name Process.  
Explanation: The indicated DELETE FILESPACE process cannot be started on  
the server.  
System Action: The DELETE FILESPACE command is ended and server  
processing continues.  
User Response: This usually indicates that sufficient server memory is not  
available on the server. Allocate additional storage to the server. For details, issue  
HELP MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0851E  
Cannot start delete file space thread for node node name.  
Explanation: The indicated DELETE FILESPACE process cannot be started on  
the server. Sufficient memory on the server may not be available.  
System Action: The DELETE FILESPACE command is ended and server  
processing continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0852E  
Command: No matching file spaces found for node node name.  
Explanation: The server did not find any file spaces for the node indicated  
matching the names specified in the command.  
System Action: The server ends the command.  
User Response: Enter the command with file space names that refer to defined file  
spaces for the specified node. Note that file space names are case sensitive. Enter  
them by using exactly the same uppercase and lowercase characters that match the  
file space name defined on the server. Use the QUERY FILESPACE command to  
determine which file spaces are defined for a node on the server.  
ANR0853E  
Transaction failed in file space deletion, DELETE FILESPACE process  
aborted.  
Explanation: A database transaction fails while the server is deleting file space  
data.  
System Action: The server ends the file space deletion process.  
146  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0854E  
ANR0855E  
ANR0856E  
ANR0857E  
Inventory file space query failure, DELETE FILESPACE process aborted.  
Explanation: The server encounters an error in querying the inventory database  
during a file space deletion process.  
System Action: The server ends the file space deletion process.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Server LOG space exhausted, DELETE FILESPACE process aborted.  
Explanation: Insufficient server log space has been encountered during file space  
deletion processing.  
System Action: The server ends the file space deletion process.  
User Response: To increase the amount of log space available to the server, an  
authorized administrator can add log volumes by using the DEFINE LOGVOLUME  
command, and can extend the size of the log by using the EXTEND LOG  
command.  
Server database space exhausted, DELETE FILESPACE process aborted.  
Explanation: Insufficient server database space has been encountered during file  
space deletion processing.  
System Action: The server ends the file space deletion process.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add log volumes using the DEFINE DBVOLUME  
command and can extend the size of the database using the EXTEND DB  
command.  
Data storage session failure, DELETE FILESPACE process aborted.  
Explanation: The server encounters an error accessing data storage during file  
space deletion processing.  
System Action: The server ends the file space deletion process.  
Tivoli Storage Manager Messages  
147  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0858E  
ANR0859E  
ANR0860E  
Inventory object search failure, DELETE FILESPACE process aborted.  
Explanation: The server encounters an error accessing the inventory database  
during file space deletion processing.  
System Action: The server ends the file space deletion process.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Data storage object erasure failure, DELETE FILESPACE process aborted.  
Explanation: The server encounters an error in removing file copies from data  
storage during file space deletion processing.  
System Action: The server ends the file space deletion process.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Expiration process process ID terminated due to internal error: examined  
number of objects objects, deleting number of backup objects backup objects,  
number of archive objects archive objects, number of DB backup volumes DB  
backup volumes, and number of recovery plan files recovery plan files. error  
count errors were encountered.  
Explanation: The server encounters an internal error during file expiration  
processing. The number of files examined and deleted prior to the error are  
reported. A total error count is also displayed.  
System Action: The server ends the expiration process.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
148  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0861E  
ANR0862E  
ANR0863E  
Transaction failed in expiration, inventory expiration aborted.  
Explanation: The server encounters a database transaction failure during policy  
roll-off processing.  
System Action: The server ends roll-off processing.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Expiration processing suspended - insufficient memory.  
Explanation: The server ends policy roll-off processing because sufficient server  
memory is not available.  
System Action: The server ends policy roll-off processing and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
Expiration processing suspended - insufficient DB space.  
Explanation: The server ends policy roll-off processing because sufficient server  
database space is not available.  
System Action: The server ends policy roll-off processing and server operation  
continues.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes by using the DEFINE  
DBVOLUME command and can extend the size of the database using the EXTEND  
DB command.  
ANR0864E  
Expiration processing suspended - insufficient LOG space.  
Explanation: The server ends policy roll-off processing because sufficient server  
log space is not available.  
System Action: The server ends policy roll-off processing and server operation  
continues.  
User Response: To increase the amount of log space available to the server, an  
authorized administrator can add log volumes by using the DEFINE LOGVOLUME  
command and can extend the size of the log by using the EXTEND LOG command.  
Tivoli Storage Manager Messages  
149  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0865E  
Expiration processing failed - internal server error.  
Explanation: Server retry processing during policy roll-off fails.  
System Action: The server ends policy roll-off processing.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the server is out of database space, issue the  
DEFINE DBVOLUME and EXTEND DB commands to add volumes to the server  
database and extend the database size. If the server is out of log space, issue the  
DEFINE LOGVOLUME and EXTEND LOG commands to add volumes to the  
server log and extend the log size. If the server is low on memory, allocate  
additional storage to the server. For details, issue HELP MEMORY to display the  
information online or see “Appendix A. Allocating Additional Server Memory”. If  
the error cannot be isolated and resolved, contact your service representative.  
ANR0866E  
Expiration processing retries failed - no success after maximum retries retries.  
Explanation: Server policy roll-off processing ends because retry processing has  
not been successful in expiring client file copies from the server database.  
System Action: The server ends policy roll-off processing and server operation  
continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the server is out of database space, issue the  
DEFINE DBVOLUME and EXTEND DB commands to add volumes to the server  
database and extend the database size. If the server is out of log space, issue the  
DEFINE LOGVOLUME and EXTEND LOG commands to add volumes to the  
server log and extend the log size. If the server is low on memory, allocate  
additional storage to the server. For details, issue HELP MEMORY to display the  
information online or see “Appendix A. Allocating Additional Server Memory”. If  
the error cannot be isolated and resolved, contact your service representative.  
ANR0867E  
Unable to open policy domain for node node name during expiration processing.  
Explanation: Policy roll-off processing on the server encounters an error while  
obtaining policy information related to the specified node.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
150  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0868E  
ANR0869E  
ANR0870E  
ANR0871E  
Cannot find management class name for ID management class ID.  
Explanation: Policy roll-off processing on the server encounters an error while  
obtaining policy information.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Cannot find policy domain for node node ID.  
Explanation: Policy roll-off processing on the server encounters an error while  
obtaining policy information related to the specified node.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Cannot find node name for node node ID.  
Explanation: Policy roll-off processing on the server encounters a database error  
in obtaining information for a client node.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Cannot find file space name for node node ID, file space file space ID.  
Explanation: Policy roll-off processing on the server encounters a database error  
in obtaining information for a client node.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Tivoli Storage Manager Messages  
151  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0872E  
ANR0873E  
ANR0874E  
Grace Period retention for domain domain name could not be obtained.  
Explanation: Policy roll-off processing on the server encounters a database error  
in obtaining GRACE PERIOD values for the specified policy domain.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Invalid copy type encountered in expiring files: copytype ID  
Explanation: Policy roll-off processing on the server encounters a database error  
in obtaining copy group information.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Backup object object.ID not found during inventory processing.  
Explanation: Inventory processing on the server encounters a database error in  
obtaining backup information in data storage.  
System Action: The server ends roll-off processing, or client session(s) and server  
operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR0875E  
Archive object object.ID not found during expiration processing.  
Explanation: Policy roll-off processing on the server encounters a database error  
in obtaining archive information in data storage.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
152  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0876E  
ANR0877E  
ANR0878E  
ANR0879E  
Data storage erasure failed during expiration processing.  
Explanation: Policy roll-off processing on the server encounters a database error  
while deleting information from data storage.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Copy type not backup for object object.ID.  
Explanation: Policy roll-off processing on the server encounters a database error  
in accessing inventory information.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Entry for backup object object.ID not found.  
Explanation: Policy roll-off processing on the server encounters a database error  
in accessing inventory information.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Error opening inventory file space query.  
Explanation: Policy roll-off processing on the server encounters a database error  
in accessing inventory information.  
System Action: The server ends roll-off processing and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
Tivoli Storage Manager Messages  
153  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0880E  
Filespace command: No matching file spaces.  
Explanation: The server did not find any file space names matching the  
specifications entered in the filespace command.  
System Action: Server operation continues.  
User Response: Use the QUERY FILESPACE command to determine which file  
spaces are defined on the server. Note, that file space names are case sensitive.  
Reissue the file space command and specify the proper file space name (in proper  
case).  
ANR0881E  
Policy Error : the GRACE PERIOD archive retention value could not be  
obtained for domain domain ID during client inventory processing.  
Explanation: The server encounters an internal error in accessing policy  
information.  
System Action: The operation is ended and server operation continues.  
User Response: Contact your service representative.  
ANR0882E  
Policy Error: Unable to open policy domain for node node name during client  
inventory query processing.  
Explanation: The server encounters an internal error in accessing policy  
information.  
System Action: The client operation is ended and server operation continues.  
User Response: Contact your service representative.  
ANR0883E  
Cannot obtain node name for node node ID.  
Explanation: The server encounters an internal error in accessing client node  
information.  
System Action: The operation is ended and server operation continues.  
User Response: Contact your service representative.  
ANR0884E  
Error code during deletion of sorting information for number objects.  
Explanation: A background server process encountered an internal error after  
deleting sorting information for number files from the server database. This process  
is started during initialization to remove any sorting information which is left over  
from previous export operations.  
System Action: The backup or archive objects were not deleted. Only the  
information used to sort these objects during the previous export operation was  
154  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
deleted. The background process was terminated before all sorting information had  
been deleted. The system will not perform further export processing of file data  
until this problem has been resolved.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. Then restart the server. If the error cannot be  
isolated and resolved, contact your service representative.  
ANR0885I  
Import command: Processing management class management class name for  
domain domain name and policy set policy set name as management class new  
management class name.  
Explanation: The background import process to service the command import  
command is currently processing the policy information for management class  
management class name in domain domain name and policy set policy set name.  
The management class is imported under the name new management class name.  
During import processing, management classes defined as either DEFAULT or  
GRACE_PERIOD must be renamed so that the management class does not conflict  
with existing server policy conventions. Import processing is then able to import file  
data by using the renamed management class.  
System Action: Import processing for the command continues.  
User Response: None. However, an administrator may want to examine the policy  
definitions for new management class name so they are aware of the management  
classes that may be used if the policy set containing this management class is  
activated.  
ANR0886E  
Management class class name in domain domain name used by node node name  
in file space filespace name has no BACKUP copy group with id copy group id;  
Expiration will not be performed for files from this node and filespace that are  
bound to this management class and copy group id.  
Explanation: During policy roll-off processing, the server finds a client file copy  
with a management class or a backup copy group that no longer exists.  
System Action: The server skips the files in error.  
User Response: For programming support, contact your service representative.  
ANR0887E  
Management class class name in domain domain name used by node node name  
in file space filespace name has no ARCHIVE copy group with id copy group id;  
Expiration will not be performed for files from this node and filespace that are  
bound to this management class and copy group id.  
Explanation: During policy roll-off processing, the server finds a client file copy  
with a management class or an archive copy group that no longer exists.  
Tivoli Storage Manager Messages  
155  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server skips the files in error.  
User Response: For programming support, contact your service representative.  
ANR0888E  
SQL commands cannot be issued from the server console.  
Explanation: An SQL command was issued from the server console. SQL  
commands cannot be issued from the server console because they may require a  
long time complete and the server console should be available to control other  
server functions.  
System Action: The server ignores the command and continues processing.  
User Response: Issue the SQL command from an administrative client.  
ANR0889E  
The server is not licensed for Central Administration functions. This includes  
the ability to issue SQL commands.  
Explanation: An SQL command was issued but the server is not licensed to  
support Central Administrative functions, including SQL query support.  
System Action: The server ignores the command and continues processing.  
User Response: If you have purchased the Central Administration license, use the  
REGISTER LICENSE command to enable the license on the server. If you have not  
purchased the license and wish to do so, contact your service representative.  
ANR0890I  
Export/import command: Processing optionset optionset name.  
Explanation: The background export or import process to service the command  
export/import command is currently processing optionset definition information.  
System Action: Export or import processing for the command continues.  
User Response: None.  
ANR0891I  
Export/import command: Copied number optionset definitions.  
Explanation: The background export or import process to service the command  
export/import command copies number client optionset definitions from the server  
database to export media or from export media into the server database. Data is not  
moved if Preview=Yes is specified in the command export/import command.  
System Action: Export or import processing for the command completes. Server  
operation continues.  
User Response: None.  
156  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0892I  
Export command: No matching optionsets found for exporting.  
Explanation: The background export process does not find any client optionsets  
for export command.  
System Action: The export process continues and no optionsets from the server.  
User Response: None.  
ANR0893I  
Are you sure that you want to accept the current system date as valid ?  
Explanation: This message is displayed when the ACCEPT DATE command has  
been issued to confirm that you want to accept the date on the system as valid.  
System Action: The command waits for you to confirm the action.  
User Response: Specify Yes if you want to accept the system date as valid, or No  
if you do nt want to execute the command.  
ANR0894I  
Current system has been accepted as valid.  
Explanation: This messages is displayed when the ACCEPT DATE command has  
been issued and the date has been accepted as valid byu the server.  
System Action: The current system date is accepted as valid by the server  
User Response: None.  
ANR0895E  
Command: Cannot Start process name Process.  
Explanation: The indicated process cannot be started on the server.  
System Action: The specified command is ended and server processing continues.  
User Response: This usually indicates that sufficient server memory is not  
available on the server. Allocate additional storage to the server. For details, issue  
HELP MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR0900I  
Processing options file filespec.  
Explanation: At server initialization, the server is reading the server options file  
whose name is shown in the message.  
System Action: The server reads and processes the options in this file.  
User Response: None.  
Tivoli Storage Manager Messages  
157  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0901W  
Invalid option statement found in file filespec.  
Explanation: While processing the server options file named, the server has  
encountered an invalid statement. The invalid statement type is shown in the  
message. The lines following this message provide more information.  
System Action: The server ignores the statement in error. Server initialization  
continues. The default value is used for any missing or ignored options.  
User Response: Ignore the error, or use a text editor to correct the error and restart  
the server.  
ANR0902W  
Unsupported keyword found in file filespec.  
Explanation: While processing the server options file named, the server has  
encountered an invalid keyword on an option statement. The lines following this  
message provide more information.  
System Action: The server ignores the option statement in error. Server  
initialization continues. The default value is used for any missing or ignored  
options.  
User Response: Ignore the error, or use a text editor to correct the error and restart  
the server.  
ANR0903W  
Excessive option statement found in file filespec.  
Explanation: While processing the specified server options file, the server has  
encountered more of the named statement type than can be processed.  
System Action: The server ignores the extra statement. Server initialization  
continues.  
User Response: Ignore the error, or use a text editor to correct the error and restart  
the server.  
ANR0904W  
Duplicate option statement found in file filespec.  
Explanation: While processing the server options file named, the server has  
encountered a duplicate statement of the type shown.  
System Action: The server ignores the duplicate statement. Server initialization  
continues.  
User Response: Ignore the error, or use a text editor to correct the error and restart  
the server.  
158  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0905W  
Options file filespec not found.  
Explanation: At server initialization, the server is unable to locate the server  
options file named.  
System Action: The server uses the default values for all options. Server  
initialization continues.  
User Response: If the default values are acceptable, ignore the error. Otherwise,  
move a valid server options file to the proper location, rename a valid options file  
to the proper name, or use a text editor to build the proper server options file, and  
then restart the server.  
ANR0909E  
Insufficient memory to process options file.  
Explanation: At server initialization, the server is unable to process the server  
options file due to insufficient memory.  
System Action: Server initialization ends.  
User Response: Restart the server with more memory available. Refer to the  
Administrators Guide for your particular platform.  
ANR0915E  
Unable to open language language name for message formatting.  
Explanation: The server is unable to open the specified message repository.  
System Action: Server initialization continues with the default message repository.  
User Response: Ensure that a valid language is specified in the LANGUAGE  
option of the server options file. If a change is made to the options file, restart the  
server to activate changes.  
ANR0916I  
Product Name distributed by Company is now ready for use.  
Explanation: The server has completed startup processing and is now ready for  
use.  
System Action: None.  
User Response: None.  
ANR0917W  
Session session number for node node name (client platform) - in domain domain  
name failed because of policy length.  
Explanation: The client cannot handle very long policies.  
System Action: The client operation is ended and server operation continues.  
Tivoli Storage Manager Messages  
159  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Upgrade the client to the latest level, or activate a policy set with  
fewer management classes.  
ANR0920I  
ANR0921I  
ANR0922I  
ANR0923E  
Tracing is now active to standard output.  
Explanation: In response to a TRACE START command, server trace records are  
being written to the standard output destination (usually the server console).  
System Action: None.  
User Response: None.  
Tracing is now active to file file spec.  
Explanation: In response to a TRACE START command, server trace records are  
being written to the file named.  
System Action: None.  
User Response: None.  
Trace ended.  
Explanation: In response to a TRACE END command, server trace records are no  
longer being written.  
System Action: None.  
User Response: None.  
Tracing is inactive.  
Explanation: A TRACE END command has been entered, but tracing is not  
active.  
System Action: The command is ignored.  
User Response: If tracing is desired, use the TRACE ENABLE and TRACE  
START commands to activate server tracing.  
ANR0924E  
Tracing is already active to file file spec.  
Explanation: A TRACE BEGIN command has been entered, but tracing is already  
active to the file named.  
System Action: The command is ignored.  
User Response: If the current trace output file is acceptable, no action is required.  
Otherwise use the TRACE END command to stop tracing and then reissue the  
TRACE BEGIN command as desired.  
160  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0925E  
Tracing is already active to standard output.  
Explanation: A TRACE BEGIN command has been entered, but tracing is already  
active to the standard output destination (usually the server console).  
System Action: The command is ignored.  
User Response: If the current trace output destination is acceptable, no action is  
required. Otherwise use the TRACE END command to stop tracing and then reissue  
the TRACE BEGIN command as desired.  
ANR0926E  
ANR0927E  
ANR0928E  
Missing or invalid TRACE command parameter.  
Explanation: The TRACE command issued contains an invalid parameter, or is  
missing a required parameter.  
System Action: The command is ignored.  
User Response: Reissue the command with the proper parameters.  
Unknown trace class keyword - class.  
Explanation: A TRACE ENABLE command has been entered which specifies an  
unknown trace class.  
System Action: The command is ignored.  
User Response: Reissue the TRACE command with the correct class.  
Unable to open trace file file spec for appending.  
Explanation: A TRACE BEGIN command specifies an output file, but the server  
cannot write to that file.  
System Action: The command is ignored.  
User Response: Check the file for proper access permissions, or reissue the  
TRACE command specifying a different output file.  
ANR0929E  
Insufficient memory to activate tracing.  
Explanation: A TRACE BEGIN command has been entered, but the server has  
insufficient memory available to activate tracing.  
System Action: The command is ignored.  
User Response: If tracing is required, make more memory available to the server  
then restart the server.  
Tivoli Storage Manager Messages  
161  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0940I  
ANR0941I  
ANR0942E  
Cancel request accepted for process process ID.  
Explanation: A CANCEL PROCESS command has been entered for the specified  
process.  
System Action: None.  
User Response: None.  
Command: Cancel for process process ID is already pending.  
Explanation: A CANCEL PROCESS command has been entered for the specified  
process, but a cancel is already pending for that process.  
System Action: The server ignores the command.  
User Response: None.  
Command: Process process ID cannot be found.  
Explanation: A CANCEL PROCESS command has been entered for the specified  
process, but the process is not active. Either the process has already ended or the  
wrong process number has been entered.  
System Action: The server ignores the command.  
User Response: If the wrong process number has been entered, reissue the  
command with the correct process number.  
ANR0943E  
Command: Process process ID could not be canceled.  
Explanation: A CANCEL PROCESS command has been entered for the specified  
process, but the process specified is an automatic process, such as migration or  
reclamation, that cannot be canceled.  
System Action: The server ignores the command.  
User Response: None.  
ANR0944E  
Command: No active processes found.  
Explanation: A QUERY PROCESS command has been entered, and no processes  
are active.  
System Action: The server ignores the command.  
User Response: None.  
162  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0945W  
DiagnosticID: Transaction transaction ID was aborted for process process ID.  
Explanation: An error is detected during transaction commit for the specified  
process. This message should be preceded by other messages that give additional  
information about the failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
ANR0960I  
Process process ID waiting for mount point in device class device class name.  
Explanation: The process whose ID is shown has begun to wait for a mount point  
that can be used for a volume in the device class shown.  
System Action: The process waits for the mount point.  
User Response: Respond to any mount requests.  
ANR0961I  
Process process ID waiting for multiple mount points in device class device class  
name.  
Explanation: The process whose ID is shown has begun to wait for multiple  
mount points that can be used for a volume in the device class shown.  
System Action: The process waits for the mount points.  
User Response: Respond to any mount requests.  
ANR0962I  
Process process ID waiting for mount points in device classes device class name  
and device class name.  
Explanation: The process whose ID is shown has begun to wait for mount points  
that can be used for a volume in the two device classes shown.  
System Action: The process waits for the mount points.  
User Response: Respond to any mount requests.  
ANR0963I  
Process process ID waiting for mount of input volume volume name.  
Explanation: The process whose ID is shown has begun to wait for the mount of  
the input volume shown.  
System Action: The process waits for the mount.  
User Response: Respond to any mount requests.  
Tivoli Storage Manager Messages  
163  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0964I  
ANR0965I  
ANR0966I  
ANR0967I  
ANR0980E  
Process process ID waiting for mount of output volume volume name.  
Explanation: The process whose ID is shown has begun to wait for the mount of  
the output volume shown.  
System Action: The process waits for the mount.  
User Response: Respond to any mount requests.  
Process process ID waiting for mount of scratch volume.  
Explanation: The process whose ID is shown has begun to wait for the mount of  
a scratch volume.  
System Action: The process waits for the mount.  
User Response: Respond to any mount requests.  
Process process ID waiting for access to input volume volume name.  
Explanation: The process whose ID is shown has begun to wait for availability of  
the input volume shown.  
System Action: The process waits for the volume to become available.  
User Response: None.  
Process process ID waiting for access to output volume volume name.  
Explanation: The process whose ID is shown has begun to wait for availability of  
the output volume shown.  
System Action: The process waits for the volume to become available.  
User Response: None.  
The server database must be audited with FIX=YES before the server can be  
started.  
Explanation: The server has been restarted after a DSMSERV LOADDB  
command processed a database image that was known to have inconsistencies. In  
order to bring the database back to a consistent state, you must run the AUDITDB  
command.  
System Action: Server initialization stops.  
User Response: Issue the DSMSERV AUDITDB FIX=YES command. For  
complete details on this command, refer to the Administrators Reference.  
164  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0981E  
ANR0982E  
ANR0983W  
The server database must be restored before the server can be started.  
Explanation: The server has been restarted after an incomplete RESTORE DB. In  
order to start the server, you must restore to the database to a consistent state using  
the DSMSERV RESTORE DB command.  
System Action: Server initialization stops.  
User Response: Issue the DSMSERV RESTORE DB command. For complete  
details on this command, refer to the Administrators Reference.  
The server database must be initialized before the database can be loaded.  
Explanation: The server database must be initialized before it can be loaded with  
the LOADDB parameter, by issuing the DSMSERV FORMAT command. The server  
database is not currently in the initialized state.  
System Action: Server LOADDB processing stops.  
User Response: Issue the DSMSERV FORMAT command. For complete details  
on this command, refer to the Administrators Reference.  
The server database was recorded by a down-level version of the server  
program. The UPGRADEDB parameter is required to start the server and  
automatically upgrade the database contents to the current server version.  
Please refer to installation instructions for precautionary backup procedures  
prior to doing this.  
Explanation: At server startup, the server has discovered that the database  
information was written by an earlier version of the server program and is not  
compatible with this version. To automatically upgrade the server database to this  
version of the server program, the UPGRADEDB parameter must be specified when  
starting the server.  
System Action: The server ends.  
User Response: Refer to installation instructions for specific information on  
precautionary measures that you may want to take to back up the database prior to  
upgrading it to the current server level. After you have taken these measures, start  
the server and specify the UPGRADEDB parameter. This parameter only needs to  
be specified once to start the server, and should NOT be included in any automated  
programs that start the server.  
ANR0984I  
Process process ID for process name started in the process state at process start  
time.  
Explanation: The process whose ID is shown has been started for the process  
indicated by the process name running in the indicated state.  
Tivoli Storage Manager Messages  
165  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR0985I  
Process process ID for process name running in the process state completed with  
completion state completion state at process start time.  
Explanation: The process whose ID is shown that was running for the process  
indicated by the process name running in the indicated state has completed with the  
completion state indicated.  
System Action: None.  
User Response: If the completion state was SUCCESS then no action is necessary.  
However, if the completion state is FAILURE then the user should review the  
activity log and/or event log to try to determine the cause of the failure.  
ANR0986I  
Process process ID for process name running in the process state processed items  
processed items for a total of bytes processed bytes with a completion state of  
completion state at process start time.  
Explanation: The process whose ID is shown that was running for the process  
indicated by the process name running in the indicated state has completed  
processing the stated number of items and total number of bytes with the  
completion state indicated.  
System Action: None.  
User Response: If the completion state was SUCCESS then no action is necessary.  
However, if the completion state is FAILURE then the user should review the  
activity log and/or event log to try to determine the cause of the failure.  
ANR0987I  
Process process ID for process name running in the process state processed items  
processed items with a completion state of completion state at process start time.  
Explanation: The process whose ID is shown that was running for the process  
indicated by the process name running in the indicated state has completed  
processing the stated number of items with the completion state indicated.  
System Action: None.  
User Response: If the completion state was SUCCESS then no action is necessary.  
However, if the completion state is FAILURE then the user should review the  
activity log and/or event log to try to determine the cause of the failure.  
166  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0988I  
Process process ID for process name running in the process state processed bytes  
processed bytes with a completion state of completion state at process start time.  
Explanation: The process whose ID is shown that was running for the process  
indicated by the process name running in the indicated state has completed  
processing the stated number of bytes with the completion state indicated.  
System Action: None.  
User Response: If the completion state was SUCCESS then no action is necessary.  
However, if the completion state is FAILURE then the user should review the  
activity log and/or event log to try to determine the cause of the failure.  
ANR0990I  
Server restart-recovery in progress.  
Explanation: The server has been restarted after a halt or system failure. If  
necessary, the server performs recovery processing in order to bring the system back  
to a consistent state.  
System Action: Server initialization continues.  
User Response: None.  
ANR0991I  
ANR0992I  
ANR0993I  
Server shutdown complete.  
Explanation: In response to a HALT command, the server has completed its  
termination processing.  
System Action: The server ends.  
User Response: None.  
Server installation complete.  
Explanation: The server installation procedure has completed successfully. The  
server is now available for normal operation.  
System Action: Server completes installation processing.  
User Response: None.  
Server initialization complete.  
Explanation: The server has been restarted after a halt or system failure. It is now  
ready to resume normal operation.  
System Action: Server completes initialization.  
User Response: None.  
Tivoli Storage Manager Messages  
167  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR0994W  
This server has not been properly installed.  
Explanation: The server was started for normal operation, but had not yet been  
installed.  
System Action: The server ends.  
User Response: Install the server properly before starting it.  
ANR0995W  
This version of the server program is down-level with respect to the  
information recorded on disk; a newer version of the program should be used.  
Explanation: At server startup, the server has discovered that the disk information  
was written by a later version of the server program. This version of the server  
program should not be used.  
System Action: The server ends.  
User Response: Start a version of the server program that is at the same level as  
the prior server program used.  
ANR0996W  
The information on disk was recorded by a down-level version of the server  
program; re-installation is required to use this version.  
Explanation: At server startup, the server has discovered that the disk information  
was written by an earlier version of the server program and is not compatible with  
this version.  
System Action: The server ends.  
User Response: Install this version of the server to bring the information up to the  
level of the program being used.  
ANR1000I  
Migration process process ID started for storage pool storage pool name.  
Explanation: Because the high migration threshold for the storage pool shown has  
been exceeded, a process has been started to migrate files from the storage pool.  
System Action: Data is moved from this storage pool to the next (target) pool.  
User Response: None.  
ANR1001I  
Migration process process ID ended for storage pool storage pool name.  
Explanation: A migration process for the named storage pool ends. This action  
can occur because the low migration threshold for the storage pool has been reached  
or because there are no more nodes with files to be migrated.  
System Action: None.  
168  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR1002I  
Migration for storage pool storage pool name will be retried in number of  
seconds seconds.  
Explanation: Because of a problem encountered attempting migration for the  
named storage pool, migration is delayed but will be retried after the time period  
shown.  
System Action: The server waits for the specified period and then retries migration  
for the storage pool. This delay applies to a single migration process. After a  
number of unsuccessful retries, the server will automatically cancel the process. If  
other migration processes are executing for the named storage pool, these processes  
will continue migration.  
User Response: If possible, correct the condition that has caused delayed  
migration.  
ANR1003I  
ANR1020W  
ANR1021W  
Migration retry delay ended; checking migration status for storage pool storage  
pool name.  
Explanation: Because migration for the indicated storage pool had been delayed  
due to a problem, the system waited before retrying. The retry wait period has  
ended, and the system will now retry migration.  
System Action: Migration processing for the storage pool resumes.  
User Response: None.  
Migration process process ID terminated for storage pool storage pool name -  
process canceled.  
Explanation: During migration for the indicated storage pool, a process  
performing the migration has been canceled.  
System Action: The migration process is terminated. If other migration processes  
are executing for the named storage pool, these processes will continue migration.  
User Response: None.  
Migration process process ID terminated for storage pool storage pool name -  
storage media inaccessible.  
Explanation: During migration for the indicated storage pool, a required volume  
could not be mounted.  
Tivoli Storage Manager Messages  
169  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: None.  
ANR1022W  
ANR1023W  
ANR1024W  
Migration process process ID terminated for storage pool storage pool name -  
excessive read errors encountered.  
Explanation: During migration for the indicated storage pool, read errors occur  
that prevented the migration from continuing.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: If possible, correct the cause of the read errors.  
Migration process process ID terminated for storage pool storage pool name -  
excessive write errors encountered.  
Explanation: During migration for the indicated storage pool, write errors occur  
that prevent the migration from continuing.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: If possible, correct the cause of the write errors.  
Migration process process ID terminated for storage pool storage pool name -  
data transfer interrupted.  
Explanation: During migration for the indicated storage pool, a data transfer  
operation was interrupted and could not be continued.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: If possible, correct the cause of the interruption.  
170  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1025W  
Migration process process ID terminated for storage pool storage pool name -  
insufficient space in subordinate storage pool.  
Explanation: During migration for the indicated storage pool, the server cannot  
move the data from the storage pool, because there is not enough space on the next  
storage pool to hold it.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again.  
User Response: Make more space available in the next storage pool, or use the  
UPDATE STGPOOL command to change the next storage pool to one with more  
space.  
ANR1026W  
Migration process process ID terminated for storage pool storage pool name -  
unable to move file to subordinate storage pool due to exclusion by size.  
Explanation: During migration for the indicated storage pool, the server cannot  
move the data from the storage pool, because a file is larger than what is allowed  
on the next storage pool.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: Use the UPDATE STGPOOL command to change the next  
storage pool maximum file size or to change the next storage pool target.  
ANR1027W  
Migration process process ID terminated for storage pool storage pool name -  
sufficient recovery log space is not available.  
Explanation: During migration for the indicated storage pool, the server runs out  
of recovery log space.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again.  
User Response: If necessary, make more server recovery log space available.  
ANR1028W  
Migration process process ID terminated for storage pool storage pool name -  
sufficient database space is not available.  
Explanation: During migration for the indicated storage pool, the server runs out  
of database space.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again.  
Tivoli Storage Manager Messages  
171  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If necessary, make more server database space available.  
ANR1029W  
Migration process process ID terminated for storage pool storage pool name -  
lock conflict.  
Explanation: During migration for the indicated storage pool, the server needs to  
obtain a lock that is not available.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: Wait for the server to retry the migration.  
ANR1030W  
Migration process process ID terminated for storage pool storage pool name -  
thread resource not available.  
Explanation: During migration for the indicated storage pool, the server cannot  
start a thread for the migration process.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: Wait for the server to retry the migration. If the error persists, it  
may indicate a shortage of server memory.  
ANR1031W  
Migration process process ID terminated for storage pool storage pool name -  
sufficient memory is not available.  
Explanation: During migration for the indicated storage pool, there is not enough  
server memory available.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again.  
User Response: If necessary, make more memory available to the server.  
ANR1032W  
Migration process process ID terminated for storage pool storage pool name -  
internal server error detected.  
Explanation: During migration for the indicated storage pool, the server  
encounters an internal error.  
172  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: Contact your service representative.  
ANR1033W  
Migration process process ID terminated for storage pool storage pool name -  
transaction aborted.  
Explanation: During migration for the indicated storage pool, the server detected  
an error while attempting to commit a transaction. This message should be preceded  
by other messages that give additional information about the failed transaction.  
System Action: The indicated migration process ends. The server waits for the  
retry period to expire and then tries the migration again. If other migration  
processes are executing for the named storage pool, these processes will continue  
migration.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction.  
ANR1034W  
Files stored on volume volume name cannot be migrated - volume is offline or  
access mode is unavailableor destroyed.  
Explanation: During migration, files on the indicated volume cannot be migrated  
either because the volume has been varied offline or because of the volume’s access  
mode.  
System Action: The server continues migration processing, but skips files stored  
on the indicated volume.  
User Response: If necessary, use the VARY ON or UPDATE VOLUME command  
for this volume.  
ANR1040I  
Space reclamation started for volume volume name, storage pool storage pool  
name (process number process ID).  
Explanation: The percentage of reclaimable space on the volume shown has  
reached the reclaim percentage specified for the storage group; as a result, data from  
the volume is moved to another volume so that the volume can be reclaimed.  
System Action: The server starts volume space reclamation.  
User Response: None.  
Tivoli Storage Manager Messages  
173  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1041I  
ANR1042I  
Space reclamation ended for volume volume name.  
Explanation: Space reclamation for the volume named is complete.  
System Action: None.  
User Response: None.  
Space reclamation for storage pool storage pool name will be retried in number  
of seconds seconds.  
Explanation: Because of a problem encountered attempting space reclamation for  
the named storage pool, reclamation stops but will be retried after the time period  
shown. After a number of unsuccessful retries, the process will be automatically  
cancelled.  
System Action: The system waits for the specified period and then retries space  
reclamation for the storage pool.  
User Response: If possible, correct the condition that has stopped reclamation.  
ANR1043I  
Space reclamation retry delay ended; checking volume reclamation status for  
storage pool storage pool name.  
Explanation: Because space reclamation for the indicated storage pool had been  
stopped due to a problem, the system waited before retrying. The retry wait period  
has ended, and the system can now retry space reclamation.  
System Action: Reclamation for the pool begins.  
User Response: None.  
ANR1044I  
Removable volume volume name is required for space reclamation.  
Explanation: During space reclamation processing, the server determines that a  
removable volume is required in order to complete processing.  
System Action: The server attempts to mount the removable volume.  
User Response: Respond to any mount request for the indicated volume.  
ANR1060W  
Error initiating space reclamation for storage pool storage pool name - lock  
conflict.  
Explanation: While attempting to initiate space reclamation for the indicated  
storage pool, the server needs to obtain a lock that is not available.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
174  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Wait for the server to retry the reclamation.  
ANR1061W  
Error initiating space reclamation for storage pool storage pool name - sufficient  
memory is not available.  
Explanation: During an attempt to initiate space reclamation for the indicated  
storage pool, there is not enough server memory available.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If necessary, make more memory available to the server.  
ANR1062W  
Error initiating space reclamation for storage pool storage pool name - internal  
server error detected.  
Explanation: During an attempt to initiate space reclamation for the indicated  
storage pool, an internal server error is encountered.  
System Action: Space reclamation stops. The server will wait for the retry period  
to expire and then tries the reclamation again.  
User Response: Contact your service representative.  
ANR1080W  
Space reclamation terminated for volume volume name - process canceled.  
Explanation: During space reclamation for the indicated volume, the process  
performing the reclamation has been canceled.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: None.  
ANR1081W  
Space reclamation terminated for volume volume name - storage media  
inaccessible.  
Explanation: During space reclamation for the indicated volume, a required  
volume cannot be mounted.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: None.  
Tivoli Storage Manager Messages  
175  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1082W  
ANR1083W  
ANR1084W  
ANR1085W  
Space reclamation terminated for volume volume name - insufficient number of  
mount points available for removable media.  
Explanation: During space reclamation for the indicated volume, the server could  
not allocate sufficient mount points for the volumes required.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If necessary, make more mount points available.  
Space reclamation terminated for volume volume name - excessive read errors  
encountered.  
Explanation: During space reclamation for the indicated volume, read errors occur  
that prevent reclamation from continuing.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If possible, determine and correct the cause of the read errors.  
Space reclamation terminated for volume volume name - excessive write errors  
encountered.  
Explanation: During space reclamation for the indicated volume, write errors  
occur that prevent reclamation from continuing.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If possible, determine and correct the cause of the write errors.  
Space reclamation terminated for volume volume name - data transfer  
interrupted.  
Explanation: During space reclamation for the indicated volume, a data transfer  
operation has been interrupted and cannot be continued.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If possible, determine and correct the cause of the interruption.  
176  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1086W  
Space reclamation terminated for volume volume name - insufficient space in  
storage pool.  
Explanation: During space reclamation for the indicated volume, the server  
determines that data cannot be moved from the volume due to insufficient space on  
other volumes in the storage pool.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: Make more space available on other volumes in the storage pool.  
ANR1087W  
Space reclamation terminated for volume volume name - sufficient recovery log  
space is not available.  
Explanation: During space reclamation for the indicated volume, the server runs  
out of recovery log space.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If necessary, make more server recovery log space available.  
ANR1088W  
Space reclamation terminated for volume volume name - sufficient database  
space is not available.  
Explanation: During space reclamation for the indicated volume, the server runs  
out of database space.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If necessary, make more server database space available.  
ANR1089W  
Space reclamation terminated for volume volume name - lock conflict.  
Explanation: During space reclamation for the indicated volume, the server  
needed to obtain a lock that is not available.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: Wait for the server to retry the reclamation.  
ANR1090W  
Space reclamation terminated for volume volume name - thread resource not  
available.  
Explanation: During space reclamation for the indicated volume, the server cannot  
start a thread for the reclamation process.  
Tivoli Storage Manager Messages  
177  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: Wait for the server to retry the reclamation. If the error persists, it  
may indicate a shortage of server memory.  
ANR1091W  
ANR1092W  
ANR1093W  
ANR1100I  
Space reclamation terminated for volume volume name - sufficient memory is  
not available.  
Explanation: During space reclamation for the indicated volume, there was not  
enough server memory available.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: If necessary, make more memory available to the server.  
Space reclamation terminated for volume volume name - internal server error  
detected.  
Explanation: During space reclamation for the indicated volume, the server  
encounters an internal error.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: Contact your service representative.  
Space reclamation terminated for volume volume name - transaction aborted.  
Explanation: During space reclamation for the indicated volume, the server  
detected an error while attempting to commit a transaction.  
System Action: Space reclamation stops. The server waits for the retry period to  
expire and then tries the reclamation again.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction.  
Migration started for volume volume name, storage pool storage pool name  
(process number process ID).  
Explanation: Because the high migration threshold for the indicated storage pool  
has been exceeded, migration of files from the volume shown begins.  
System Action: The system moves the data from this volume to the next (target)  
pool.  
User Response: None.  
178  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1101I  
ANR1102I  
ANR1115W  
Migration ended for volume volume name.  
Explanation: Because the low migration threshold for the indicated storage pool  
has been reached, migration of files from the indicated volume ends.  
System Action: None.  
User Response: None.  
Removable volume volume name is required for migration.  
Explanation: During migration processing, the server determines that a removable  
volume is required in order to complete processing.  
System Action: The server attempts to mount the removable volume.  
User Response: Respond to any mount request for the indicated volume.  
Error initiating migration for storage pool storage pool name - lock conflict.  
Explanation: While trying to start migration for the indicated storage pool, the  
server needs to obtain a lock that is not available.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Wait for the server to retry the migration.  
ANR1116W  
Error initiating migration for storage pool storage pool name - sufficient  
memory is not available.  
Explanation: While trying to start migration for the indicated storage pool, there  
is not enough server memory available.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If necessary, make more memory available to the server.  
ANR1117W  
Error initiating migration for storage pool storage pool name - internal server  
error detected.  
Explanation: While trying to start migration for the indicated storage pool, the  
server encounters an internal error.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
179  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1120W  
ANR1121W  
ANR1122W  
Migration terminated for volume volume name - process canceled.  
Explanation: During migration for the indicated volume, the process performing  
the migration has been canceled.  
System Action: The migration process is terminated. If other migration processes  
are executing for the named storage pool, these processes will continue migration.  
User Response: None.  
Migration terminated for volume volume name - storage media inaccessible.  
Explanation: During migration for the indicated volume a required volume cannot  
be mounted.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: None.  
Migration terminated for volume volume name - insufficient number of mount  
points available for removable media.  
Explanation: During migration for the indicated volume the server could not  
allocate sufficient mount points for the volumes required.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If necessary, make more mount points available.  
ANR1123W  
Migration terminated for volume volume name - excessive read errors  
encountered.  
Explanation: During migration for the indicated volume, read errors occurred that  
prevent the migration from continuing.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If possible, correct the cause of the read errors.  
ANR1124W  
Migration terminated for volume volume name - excessive write errors  
encountered.  
Explanation: During migration for the indicated volume, write errors occurred that  
prevent the migration from continuing.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
180  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If possible, correct the cause of the write errors.  
ANR1125W  
Migration terminated for volume volume name - data transfer interrupted.  
Explanation: During migration for the indicated volume a data transfer operation  
was interrupted and could not be continued.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If possible, determine and correct the cause of the interruption.  
ANR1126W  
Migration terminated for volume volume name - insufficient space in  
subordinate storage pools.  
Explanation: During migration for the indicated volume, the server cannot move  
the data from the volume because there is not enough space on the next storage  
pool to hold it.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Make more space available in the next storage pool or use the  
UPDATE STGPOOL command to change the next storage pool to one with more  
space.  
ANR1127W  
Migration terminated for volume volume name - unable to move file to  
subordinate storage pool due to exclusion by size.  
Explanation: During migration for the indicated volume, the server cannot move  
the data from the volume because a file size is larger than allowed on the next  
storage pool.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Use the UPDATE STGPOOL command to change the next  
storage pool maximum file size or to change the next storage pool target.  
ANR1128W  
Migration terminated for volume volume name - sufficient recovery log space is  
not available.  
Explanation: During migration for the indicated volume, the server runs out of  
recovery log space.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If necessary, make more server recovery log space available.  
Tivoli Storage Manager Messages  
181  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1129W  
Migration terminated for volume volume name - sufficient database space is not  
available.  
Explanation: During migration for the indicated volume pool, the server runs out  
of database space.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If necessary, make more server database space available.  
ANR1130W  
Migration terminated for volume volume name - lock conflict.  
Explanation: During migration for the indicated volume, the server needs to  
obtain a lock that is not available.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Wait for the server to retry the migration.  
ANR1131W  
Migration terminated for volume volume name - thread resource not available.  
Explanation: During migration for the indicated volume, the server cannot start a  
thread for the migration process.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Wait for the server to retry the migration. If the error persists, it  
may indicate a shortage of server memory.  
ANR1132W  
Migration terminated for volume volume name - sufficient memory is not  
available.  
Explanation: During migration for the indicated volume, there is not enough  
server memory available.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If necessary, make more memory available to the server.  
ANR1133W  
Migration terminated for volume volume name - internal server error detected.  
Explanation: During migration for the indicated volume, the server encounters an  
internal error.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
182  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your service representative.  
ANR1134W  
ANR1135W  
ANR1140I  
Migration terminated for storage pool storage pool name - insufficient number  
of mount points available for removable media.  
Explanation: During migration for the indicated storage pool the server could not  
allocate sufficient mount points in the next storage pool.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: If necessary, make more mount points available.  
Migration terminated for volume volume name - transaction aborted.  
Explanation: During migration for the indicated volume, the server detected an  
error while attempting to commit a transaction.  
System Action: Migration stops. The server waits for the retry period to expire  
and then tries the migration again.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction.  
Move data process started for volume volume name (process ID process ID).  
Explanation: As a result of a MOVE DATA command, a process begins to move  
data from the volume shown.  
System Action: The server moves all data from the volume.  
User Response: None.  
ANR1141I  
ANR1142I  
Move data process ended for volume volume name.  
Explanation: The MOVE DATA command for the volume shown completes.  
System Action: None.  
User Response: None.  
Moving data for collocation cluster cluster number of total clusters on volume  
volume name.  
Explanation: As a result of a MOVE DATA command, data moves from the  
volume indicated to new volumes; the message shows the total number of clusters  
(data objects) on the volume and the current cluster being processed.  
System Action: None.  
Tivoli Storage Manager Messages  
183  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR1143W  
ANR1144W  
Move data process terminated for volume volume name - process canceled.  
Explanation: During move data processing for the indicated volume, the process  
performing the move data was canceled.  
System Action: The server ends the MOVE DATA command.  
User Response: None.  
Move data process terminated for volume volume name - storage media  
inaccessible.  
Explanation: During move data processing for the indicated volume, a required  
volume cannot be mounted.  
System Action: The server ends the MOVE DATA command.  
User Response: None.  
ANR1145W  
Move data process terminated for volume volume name - insufficient number of  
mount points available for removable media.  
Explanation: During move data processing for the indicated volume, the server  
could not allocate sufficient mount points for the volumes required.  
System Action: The server ends the MOVE DATA command.  
User Response: If necessary, make more mount points available.  
ANR1146W  
Move data process terminated for volume volume name - excessive read errors  
encountered.  
Explanation: During move data processing for the indicated volume, read errors  
occurred that prevented the move from continuing.  
System Action: The server ends the MOVE DATA command.  
User Response: If possible, correct the cause of the read errors and then reissue  
the MOVE DATA command.  
ANR1147W  
Move data process terminated for volume volume name - excessive write errors  
encountered.  
Explanation: During move data processing for the indicated volume, write errors  
occurred that prevented the move from continuing.  
System Action: The server ends the MOVE DATA command.  
184  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If possible, correct the cause of the write errors and then reissue  
the MOVE DATA command.  
ANR1148W  
Move data process terminated for volume volume name - data transfer  
interrupted.  
Explanation: During move data processing for the indicated volume a data  
transfer operation was interrupted and could not be continued.  
System Action: The server ends the MOVE DATA command.  
User Response: If possible, determine and correct the cause of the interruption.  
ANR1149W  
Move data process terminated for volume volume name - insufficient space in  
target storage pool.  
Explanation: During move data processing for the indicated volume, the server  
cannot move the data from the volume, because there is not enough space on the  
destination storage pool to hold it.  
System Action: The server ends the MOVE DATA command.  
User Response: Make more space available in the next storage pool, or specify a  
storage pool with more space, and reissue the MOVE DATA command.  
ANR1150W  
Move data process terminated for volume volume name - unable to move file to  
target storage pool due to exclusion by size.  
Explanation: During move data processing for the indicated volume, the server  
cannot move the data from the volume because a file size is larger than allowed on  
the next storage pool.  
System Action: The server ends the MOVE DATA command.  
User Response: Use the UPDATE STGPOOL command to change the next  
storage pool maximum file size or to change the next storage pool target, and then  
reissue the MOVE DATA command.  
ANR1151W  
Move data process terminated for volume volume name - sufficient recovery log  
space is not available.  
Explanation: During move data processing for the indicated volume, the server  
runs out of recovery log space.  
System Action: The server ends the MOVE DATA command.  
User Response: If necessary, make more server recovery log space available.  
Tivoli Storage Manager Messages  
185  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1152W  
Move data process terminated for volume volume name - sufficient database  
space is not available.  
Explanation: During move data processing for the indicated volume, the server  
runs out of database space.  
System Action: The server ends the MOVE DATA command.  
User Response: If necessary, make more server database space available.  
ANR1153W  
ANR1154W  
Move data process terminated for volume volume name - lock conflict.  
Explanation: During move data processing for the indicated volume, the server  
needs to obtain a lock that was not available.  
System Action: The server ends the MOVE DATA command.  
User Response: Reissue the MOVE DATA command.  
Move data process terminated for volume volume name - thread resource not  
available.  
Explanation: During move data processing for the indicated volume, the server  
cannot start a thread for the migration process.  
System Action: The server ends the MOVE DATA command.  
User Response: Reissue the MOVE DATA command. If the error persists, it may  
indicate a shortage of server memory.  
ANR1155W  
Move data process terminated for volume volume name - sufficient memory is  
not available.  
Explanation: During move data processing for the indicated volume, there is not  
enough server memory available.  
System Action: The server ends the MOVE DATA command.  
User Response: If necessary, make more memory available to the server, and then  
reissue the MOVE DATA command.  
ANR1156W  
Move data process terminated for volume volume name - internal server error  
detected.  
Explanation: During move data processing for the indicated volume, the server  
encounters an internal error.  
System Action: The server ends the MOVE DATA command.  
User Response: Contact your service representative.  
186  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1157I  
Removable volume volume name is required for Move Data process.  
Explanation: During move data processing for the indicated volume, the server  
determines that a removable volume is required in order to complete processing.  
System Action: The server attempts to mount the removable volume.  
User Response: Respond to any mount request for the indicated volume.  
ANR1160W  
Transaction was aborted for volume volume name.  
Explanation: An error was detected during transaction commit. This message  
should be preceded by other messages that give additional information about the  
failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
ANR1161W  
Move Data skipping damaged file on volume volume name: Node node name,  
Type file type, File space filespace name, File name file name.  
Explanation: During move data, a file is encountered that was previously found to  
be damaged. If this file is part of an aggregate, the entire aggregate was previously  
marked damaged, possibly because an integrity error was detected for some other  
file within the aggregate.  
System Action: The damaged file is not moved.  
User Response: Audit the indicated volume with FIX=NO to verify that the file is  
damaged. The audit will reset the file status if the file is found to be undamaged  
during the audit. If the file is part of an aggregate, the audit will reset the aggregate  
status if the entire aggregate is found to be undamaged. If this volume is in a  
primary storage pool that has previously been backed up to a copy storage pool,  
attempt to restore damaged files by using the RESTORE STGPOOL command.  
ANR1162W  
Space reclamation skipping damaged file on volume volume name: Node node  
name, Type file type, File space filespace name, File name file name.  
Explanation: During reclamation, a file is encountered that was previously found  
to be damaged. If this file is part of an aggregate, the entire aggregate was  
previously marked damaged, possibly because an integrity error was detected for  
some other file within the aggregate.  
System Action: The damaged file is not moved.  
Tivoli Storage Manager Messages  
187  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Audit the indicated volume with FIX=NO to verify that the file is  
damaged. The audit will reset the file status if the file is found to be undamaged  
during the audit. If the file is part of an aggregate, the audit will reset the aggregate  
status if the entire aggregate is found to be undamaged. If this volume is in a  
primary storage pool that has previously been backed up to a copy storage pool,  
attempt to restore damaged files by using the RESTORE STGPOOL command.  
ANR1163W  
Offsite volume volume name still contains files which could not be moved.  
Explanation: During processing of a MOVE DATA command or reclamation, the  
server determined that the indicated offsite volume contained one or more files that  
could not be moved. One or more files could not be copied from the other available  
volumes.  
System Action: None.  
User Response: Check for messages indicating reasons why files could not be  
moved. To complete the move operation, you have several options:  
Bring the volume back on site and reissue a MOVE DATA command to reclaim  
the volume.  
Make the primary volumes available and reissue a MOVE DATA command to  
reclaim the volume.  
Delete the files by using the DELETE VOLUME command.  
ANR1165E  
Data-integrity error detected for file in storage pool storage pool name: Node  
node name, Type file type, File space filespace name, File name file name.  
Explanation: The server has detected a data-integrity error for the indicated file.  
System Action: The file will be marked damaged in the server database, and will  
not be accessed for future operations. If this file is part of an aggregate, the entire  
aggregate will be marked damaged. If a usable copy of the file exists in another  
storage pool, that copy may be accessed for future operations involving the file.  
User Response: If the indicated storage pool is a primary pool, and a usable copy  
of the file exists in a copy storage pool, you can recreate the file in the primary  
pool using the RESTORE STGPOOL command. If the indicated storage pool is a  
copy storage pool, it is possible that the primary copy of the file is usable, but was  
not accessed because the access mode for the primary storage pool or volume is  
unavailable. If this is the case, the primary copy of the file may be made accessible  
by changing the access mode of the primary pool or volume.  
188  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1166E  
Move Data for offsite volume cannot copy damaged file in storage pool storage  
pool name: Node node name, Type file type, File space filespace name, File name  
file name.  
Explanation: A move data process for an offsite volume cannot locate an  
undamaged copy of the specified file in any storage pool accessible by the server. If  
this file is part of an aggregate, the process could not locate an undamaged copy of  
the aggregate to which the file belongs.  
System Action: The file will skipped and will not be moved from the offsite  
volume.  
User Response: The indicated storage pool is a primary pool that contains a  
damaged copy of the file. The only usable copy of the file may now only reside on  
the offsite volume that was involved in the move data process. If you bring this  
volume back onsite, you can recreate the file in the primary pool by using the  
RESTORE STGPOOL command. After the restore, you can reissue the MOVE  
DATA command.  
ANR1167E  
Space reclamation for offsite volume(s) cannot copy damaged file in storage  
pool storage pool name: Node node name, Type file type, File space filespace  
name, File name file name.  
Explanation: A reclamation process of offsite volumes cannot locate an  
undamaged copy of the specified file in any storage pool accessible by the server. If  
this file is part of an aggregate, the process could not locate an undamaged copy of  
the aggregate to which the file belongs.  
System Action: The file is skipped and will not be moved from the offsite volume.  
User Response: The indicated storage pool is a primary pool that contains a  
damaged copy of the file. The only usable copy of the file may now only reside on  
an offsite volume that was involved in the reclamation process, but was not totally  
reclaimed. If you bring this volume back onsite, you can recreate the file in the  
primary pool by using the RESTORE STGPOOL command.  
ANR1168W  
Migration skipping damaged file on volume volume name: Node node name,  
Type file type, File space filespace name, File name file name.  
Explanation: During migration, a file is encountered that was previously found to  
be damaged. If this file is part of an aggregate, the entire aggregate was previously  
marked damaged, possibly because an integrity error was detected for some other  
file within the aggregate.  
System Action: The damaged file will not be moved.  
User Response: Audit the indicated volume with FIX=NO to verify that the file is  
damaged. The audit will reset the file status if the file is found to be undamaged  
Tivoli Storage Manager Messages  
189  
Download from Www.Somanuals.com. All Manuals Search And Download.  
during the audit. If the file is part of an aggregate, the audit will reset the aggregate  
status if the entire aggregate is found to be undamaged. If this volume is in a  
primary storage pool that has previously been backed up to a copy storage pool, you  
can also attempt to restore damaged files by using the RESTORE STGPOOL  
command.  
ANR1169W  
Lock conflict on movement of offsite file - file is skipped.  
Explanation: During migration, reclamation, or move data processing of a volume  
that is offsite, a copy of the file that resides in a primary disk storage pool is locked  
by another process.  
System Action: The file is skipped and the process will try to find another copy of  
the file in a copy storage pool. If another copy cannot be used, the move operation  
on the volume may be incomplete.  
User Response: If a move operation was incomplete, try repeating the operation.  
ANR1170E  
Out of Space in target copy storage pool: copy storage pool name.  
Explanation: During reclamation, or move data processing of a volume that is  
offsite, there was no volume available in the specified target copy storage pool.  
System Action: The operation is terminated.  
User Response: Define volumes to the copy storage pool or raise the  
MAXSCRATCH value.  
ANR1171W  
Unable to move files associated with node node name, filespace filespace name  
on volume volume name due to restore in progress.  
Explanation: During movement of data (migration, reclamation, move data) from  
a sequential volume, one or more files were encountered that were locked by a  
restore operation.  
System Action: The files are not moved, but are skipped.  
User Response: Use the QUERY RESTORE FORMAT=DETAILED command to  
determine if the restore operation is active or is in restartable state. A restartable  
restore operation will keep the files locked from movement until the  
RESTOREINTERVAL is reached. QUERY OPTION will display this interval. You  
may wish to lower the RESTOREINTERVAL to cause a restartable restore operation  
to be removed and free up the locked files. The RESTOREINTERVAL is a server  
option.  
190  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1172E  
Move Data for offsite volume cannot copy file in storage pool storage pool  
name: Node node name, Type file type, File space filespace name, File name file  
name.  
Explanation: A move data process for an offsite volume cannot locate a copy of  
the specified file in any storage pool accessible by the server. If this file is part of  
an aggregate, the process could not locate copy of the aggregate to which the file  
belongs on an accessible volume.  
System Action: The file will skipped and will not be moved from the offsite  
volume.  
User Response: The indicated storage pool is a primary pool that should contain a  
primary copy of the file. Perhaps the volume on which that file resides is on a  
destroyed volume. The only usable copy of the file may now only reside on the  
offsite volume that was involved in the move data process. If you bring this volume  
back onsite, you can recreate the file in the primary pool by using the RESTORE  
STGPOOL command. After the restore, you can reissue the MOVE DATA  
command.  
ANR1173E  
Space reclamation for offsite volume(s) cannot copy file in storage pool storage  
pool name: Node node name, Type file type, File space filespace name, File name  
file name.  
Explanation: A reclamation process of offsite volumes cannot locate a copy of the  
specified file in any storage pool accessible by the server. If this file is part of an  
aggregate, the process could not locate a copy of the aggregate to which the file  
belongs on an accessible volume.  
System Action: The file is skipped and will not be moved from the offsite volume.  
User Response: The indicated storage pool is a primary pool that should contain a  
copy of the file. Perhaps the volume on which that file resides is on a destroyed  
volume. The only usable copy of the file may now only reside on an offsite volume  
that was involved in the reclamation process, but was not totally reclaimed. If you  
bring this volume back onsite, you can recreate the file in the primary pool by using  
the RESTORE STGPOOL command.  
ANR1174W  
One or more cached files were not deleted on volume volume name.  
Explanation: The MOVE DATA command could not delete one or more cached  
files on the disk volume shown. Migration was probably running at the same time,  
creating cached files while the MOVE DATA command was trying to delete them.  
System Action: The MOVE DATA command ran to completion.  
User Response: If you want the remaining cached files removed from the disk  
volume, reissue the MOVE DATA command.  
Tivoli Storage Manager Messages  
191  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1175W  
Volume volume name contains files which could not be reclaimed.  
Explanation: After reclamation of the indicated volume, it still contains one or  
more files that could not be reclaimed. These files were skipped because of read  
errors, or because the files are marked damaged.  
System Action: The volume is marked unavailable so it will not be chosen again  
for reclamation.  
User Response:  
Use the UPDATE VOLUME command to set the volume access to readonly.  
Try using the MOVE DATA command to manually reclaim the volume.  
If files still exist on the volume, audit the volume using AUDIT VOLUME  
FIX=YES.  
Try using the MOVE DATA command again.  
Use the RESTORE VOLUME command to restore files marked damaged.  
ANR1180W  
ANR1181E  
ANR1199I  
Access mode for volume volume name has been set to unavailabledue to file  
read or integrity errors.  
Explanation: During processing of a storage pool volume, input/output or other  
errors occur that force the server to mark the volume unavailable for further  
processing.  
System Action: The server sets the volume status to unavailable.  
User Response: Correct the errors that set the volume to unavailable, or use the  
DELETE VOLUME command to remove it from the system.  
DiagnosticID: Data storage transaction transaction ID was aborted.  
Explanation: A database transaction failed because of an error that was detected  
during data storage processing. This message should be preceded by other messages  
that give additional information about the failed transaction.  
System Action: The server operation that encountered this error during data  
storage processing fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction.  
Removable volume volume name is required for audit process.  
Explanation: During audit volume processing for the indicated volume, the server  
determines that a removable volume is required in order to complete processing.  
192  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server attempts to mount the removable volume.  
User Response: Respond to any mount request for the indicated volume.  
ANR1210I  
Backup of primary storage pool primary pool name to copy storage pool copy  
pool name started as process process ID.  
Explanation: A process has been started to back up a primary storage pool to the  
indicated copy storage pool.  
System Action: For every noncached file in the primary pool, a backup copy is  
made in the copy pool, if a copy of that file does not already exist.  
User Response: None.  
ANR1211I  
Backup preview of primary storage pool primary pool name to copy storage  
pool copy pool name started as process process ID.  
Explanation: A preview process has been started to back up a primary storage  
pool to the indicated copy storage pool.  
System Action: Preview information about the backup operation is collected and  
displayed, but files are not backed up.  
User Response: None.  
ANR1212I  
ANR1213I  
Backup process process ID ended for storage pool storage pool name.  
Explanation: A backup process for the named primary storage pool has ended.  
System Action: None.  
User Response: None.  
Backup process process ID terminated for storage pool storage pool name -  
process canceled.  
Explanation: During backup of the indicated primary storage pool, a process  
performing the backup has been canceled.  
System Action: If other backup processes are executing for the named storage  
pool, these processes continue.  
User Response: None.  
Tivoli Storage Manager Messages  
193  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1214I  
Backup of primary storage pool primary pool name to copy storage pool copy  
pool name has ended. Files Backed Up: number of files, Bytes Backed Up:  
number of bytes, Unreadable Files: number of unreadable files, Unreadable Bytes:  
number of bytes in unreadable files.  
Explanation: Backup processing for the specified storage pool has ended with the  
results shown.  
System Action: None.  
User Response: Examine previous messages to determine whether all backup  
processes ended successfully.  
ANR1215I  
Backup preview of primary storage pool primary pool name to copy storage  
pool copy pool name has ended. Files Backed Up: number of files, Bytes Backed  
Up: number of bytes.  
Explanation: Backup preview processing for the specified storage pool has ended  
with the results shown.  
System Action: None.  
User Response: None.  
ANR1216E  
ANR1217E  
Command: Process process ID terminated - storage media inaccessible.  
Explanation: During backup processing, a required volume could not be mounted.  
System Action: The indicated backup process ends.  
User Response: None.  
Command: Process process ID terminated - insufficient number of mount points  
available for removable media.  
Explanation: During backup processing, the server could not allocate sufficient  
mount points for the volumes required.  
System Action: The indicated backup process ends.  
User Response: If necessary, make more mount points available.  
ANR1218E  
Command: Process process ID terminated - excessive read errors encountered.  
Explanation: During backup processing, read errors occur that prevent the backup  
from continuing.  
System Action: The indicated backup process ends.  
194  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If possible, correct the cause of the read errors and reissue the  
backup command.  
ANR1219E  
ANR1220E  
ANR1221E  
Command: Process process ID terminated - excessive write errors encountered.  
Explanation: During backup processing, write errors occur that prevent the backup  
from continuing.  
System Action: The indicated backup process ends.  
User Response: If possible, correct the cause of the write errors and reissue the  
backup command.  
Command: Process process ID terminated - data transfer interrupted.  
Explanation: During backup processing, a data transfer operation was interrupted  
and could not be continued.  
System Action: The indicated backup process ends.  
User Response: If possible, correct the cause of the interruption and reissue the  
backup command.  
Command: Process process ID terminated - insufficient space in target copy  
storage pool.  
Explanation: During backup processing, the server cannot copy data to the copy  
storage pool because not enough space is available in the copy storage pool.  
System Action: The indicated backup process ends.  
User Response: Make more space available in the copy storage pool and reissue  
the backup command, or reissue the backup command and specify another copy  
storage pool with more space.  
ANR1222E  
Command: Process process ID terminated - sufficient recovery log space is not  
available.  
Explanation: During backup processing, the server runs out of recovery log space.  
System Action: The indicated backup process ends.  
User Response: If necessary, make more server recovery log space available.  
Tivoli Storage Manager Messages  
195  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1223E  
ANR1224E  
ANR1225E  
ANR1226E  
Command: Process process ID terminated - sufficient database space is not  
available.  
Explanation: During backup processing, the server runs out of database space.  
System Action: The indicated backup process ends.  
User Response: If necessary, make more server database space available.  
Command: Process process ID terminated - lock conflict.  
Explanation: During backup processing, the server needs to obtain a lock that is  
not available.  
System Action: The indicated backup process ends.  
User Response: Reissue the backup command.  
Command: Process process ID terminated - thread resource not available.  
Explanation: During backup processing, the server cannot start a thread.  
System Action: The indicated backup process ends.  
User Response: Reissue the backup command. If the error persists, it may indicate  
a shortage of server memory.  
Command: Process process ID terminated - sufficient memory is not available.  
Explanation: During backup processing, not enough server memory is available.  
System Action: The indicated backup process ends.  
User Response: If necessary, make more memory available to the server, and then  
reissue the backup command.  
ANR1227E  
ANR1228I  
Command: Process process ID terminated - internal server error detected.  
Explanation: During backup processing, the server encounters an internal error.  
System Action: The indicated backup process ends.  
User Response: Contact your service representative.  
Removable volume volume name is required for storage pool backup.  
Explanation: During processing of a BACKUP STGPOOL command, the server  
determines that a removable volume is required.  
196  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Unless this is a preview process, the server attempts to mount the  
removable volume.  
User Response: Respond to any mount request for the indicated volume.  
ANR1229W  
Volume volume name cannot be backed up - volume is offline or access mode is  
unavailableor destroyed.  
Explanation: During storage pool backup, a volume cannot be backed up either  
because it has been varied offline or because of the volume’s access mode.  
System Action: The server continues backup processing, but skips the indicated  
volume.  
User Response: If necessary, use the VARY ON or UPDATE VOLUME command  
for this volume and restart the backup command.  
ANR1230I  
Restore of primary storage pool primary pool name started as process process  
ID.  
Explanation: A process has been started to restore the indicated primary storage  
pool.  
System Action: Noncached files that reside in the named primary storage pool are  
restored if either of the following criteria are met:  
The file is stored on a volume whose access mode is destroyed  
The primary file has been identified as having data-integrity errors during a  
previous operation  
User Response: None.  
ANR1231I  
Restore preview of primary storage pool primary pool name started as process  
process ID.  
Explanation: A preview process has been started to restore a primary storage pool.  
System Action: Preview information about the restore operation is collected and  
displayed, but files are not restored. The restore preview includes noncached files  
that reside in the specified primary storage pool and that meet either of the  
following conditions:  
The file is stored on a volume whose access mode is destroyed  
The primary file has been identified as having data-integrity errors during a  
previous operation  
User Response: None.  
Tivoli Storage Manager Messages  
197  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1232I  
Restore of volumes in primary storage pool primary pool name started as  
process process ID.  
Explanation: A process has been started to restore one or more volumes in the  
indicated primary storage pool.  
System Action: Noncached files that reside on selected volumes in the primary  
storage pool are restored.  
User Response: None.  
ANR1233I  
Restore preview of volumes in primary storage pool primary pool name started  
as process process ID.  
Explanation: A preview process has been started to restore one or more volumes  
in the indicated primary storage pool.  
System Action: Preview information about the restore operation is collected and  
displayed, but files are not restored. The restore preview includes noncached files  
that reside on selected volumes in the primary storage pool.  
User Response: None.  
ANR1234I  
ANR1235I  
Restore process process ID ended for storage pool storage pool name.  
Explanation: A restore process for the named primary storage pool has ended.  
System Action: None.  
User Response: None.  
Restore process process ID ended for volumes in storage pool storage pool name.  
Explanation: A restore process for volumes in the named primary storage pool has  
ended.  
System Action: None.  
User Response: None.  
ANR1236I  
Restore process process ID terminated for storage pool storage pool name -  
process canceled.  
Explanation: During restore of the indicated primary storage pool, a process  
performing the restore has been canceled.  
System Action: If other restore processes are executing for the named storage  
pool, these processes continue.  
User Response: None.  
198  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1237I  
Restore process process ID terminated for volumes in storage pool storage pool  
name - process canceled.  
Explanation: During restore of volumes in the indicated primary storage pool, a  
process performing the restore has been canceled.  
System Action: If other restore processes are executing for the volumes, these  
processes continue.  
User Response: None.  
ANR1238I  
Restore of primary storage pool primary pool name has ended. Files Restored:  
number of files, Bytes Restored: number of bytes, Unreadable Files: number of  
unreadable files, Unreadable Bytes: number of bytes in unreadable files.  
Explanation: Restore processing for the specified storage pool has ended with the  
results shown.  
System Action: None.  
User Response: Examine previous messages to determine whether all restore  
processes ended successfully.  
ANR1239I  
Restore preview of primary storage pool primary pool name has ended. Files  
Restored: number of files, Bytes Restored: number of bytes.  
Explanation: Restore preview processing for the specified storage pool has ended  
with the results shown.  
System Action: None.  
User Response: None.  
ANR1240I  
Restore of volumes in primary storage pool primary pool name has ended. Files  
Restored: number of files, Bytes Restored: number of bytes, Unreadable Files:  
number of unreadable files, Unreadable Bytes: number of bytes in unreadable files.  
Explanation: Restore processing for volumes in the specified storage pool has  
ended with the results shown.  
System Action: None.  
User Response: Examine previous messages to determine whether all restore  
processes ended successfully.  
Tivoli Storage Manager Messages  
199  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1241I  
Restore preview of volumes in primary storage pool primary pool name has  
ended. Files Restored: number of files, Bytes Restored: number of bytes.  
Explanation: Restore preview processing for volumes in the specified storage pool  
has ended with the results shown.  
System Action: None.  
User Response: None.  
ANR1242E  
ANR1243E  
Command: Process process ID terminated - storage media inaccessible.  
Explanation: During restore processing, a required volume could not be mounted.  
System Action: The indicated restore process ends.  
User Response: None.  
Command: Process process ID terminated - insufficient number of mount points  
available for removable media.  
Explanation: During restore processing, the server could not allocate sufficient  
mount points for the volumes required.  
System Action: The indicated restore process ends.  
User Response: If necessary, make more mount points available.  
ANR1244E  
Command: Process process ID terminated - excessive read errors encountered.  
Explanation: During restore processing, read errors occur that prevent the restore  
from continuing.  
System Action: The indicated restore process ends.  
User Response: If possible, correct the cause of the read errors and reissue the  
restore command.  
ANR1245E  
Command: Process process ID terminated - excessive write errors encountered.  
Explanation: During restore processing, write errors occur that prevent the restore  
from continuing.  
System Action: The indicated restore process ends.  
User Response: If possible, correct the cause of the write errors and reissue the  
restore command.  
200  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1246E  
Command: Process process ID terminated - data transfer interrupted.  
Explanation: During restore processing, a data transfer operation was interrupted  
and could not be continued.  
System Action: The indicated restore process ends.  
User Response: If possible, correct the cause of the interruption and reissue the  
restore command.  
ANR1247E  
Command: Process process ID terminated - insufficient space in target primary  
storage pool.  
Explanation: During restore processing, the server cannot copy data to the target  
primary storage pool, because not enough space is available in the target pool.  
System Action: The indicated restore process ends.  
User Response: Make more space available in the target primary storage pool, and  
then reissue the restore command.  
ANR1248E  
ANR1249E  
ANR1250E  
Command: Process process ID terminated - sufficient recovery log space is not  
available.  
Explanation: During restore processing, the server runs out of recovery log space.  
System Action: The indicated restore process ends.  
User Response: If necessary, make more server recovery log space available.  
Command: Process process ID terminated - sufficient database space is not  
available.  
Explanation: During restore processing, the server runs out of database space.  
System Action: The indicated restore process ends.  
User Response: If necessary, make more server database space available.  
Command: Process process ID terminated - lock conflict.  
Explanation: During restore processing, the server needs to obtain a lock that is  
not available.  
System Action: The indicated restore process ends.  
User Response: Reissue the restore command.  
Tivoli Storage Manager Messages  
201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1251E  
Command: Process process ID terminated - thread resource not available.  
Explanation: During restore processing, the server cannot start a thread.  
System Action: The indicated restore process ends.  
User Response: Reissue the restore command. If the error persists, it may indicate  
a shortage of server memory.  
ANR1252E  
Command: Process process ID terminated - sufficient memory is not available.  
Explanation: During restore processing, there is not enough server memory  
available.  
System Action: The indicated restore process ends.  
User Response: If necessary, make more memory available to the server; and then  
reissue the restore command.  
ANR1253E  
ANR1254I  
Command: Process process ID terminated - internal server error detected.  
Explanation: During restore processing, the server encounters an internal error.  
System Action: The indicated restore process ends.  
User Response: Contact your service representative.  
Removable volume volume name is required for restore processing.  
Explanation: During processing of a RESTORE STGPOOL or RESTORE  
VOLUME command, the server determines that a removable volume is required.  
System Action: Unless this is a preview process, the server attempts to mount the  
removable volume.  
User Response: Respond to any mount request for the indicated volume.  
ANR1255W  
Files on volume volume name cannot be restored - access mode is unavailable″  
or offsite.  
Explanation: During processing of a RESTORE STGPOOL or RESTORE  
VOLUME command, files on a copy storage pool volume cannot be restored  
because of the volume’s access mode.  
System Action: The server continues restore processing, but skips the indicated  
volume.  
User Response: If the volume is stored at an offsite location, bring the volume  
onsite. Use the UPDATE VOLUME command to change the access mode for the  
volume and restart the restore command.  
202  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1256W  
Volume volume name contains files that could not be restored.  
Explanation: During processing of a RESTORE STGPOOL or RESTORE  
VOLUME command, the server determines that the indicated volume contains one  
or more files that could not be restored. If this is a preview operation, this message  
indicates that a restorable backup copy cannot be found for one or more files on the  
indicated volume. If this is an actual restore operation, this message could result if  
any of the following conditions exist for a file on the indicated volume:  
A restorable backup copy cannot be found for the file.  
A restorable backup copy of the file exists, but is located on a copy storage  
pool volume whose access mode is unavailable or offsite.  
During restore processing, a backup copy was selected for restore processing,  
but was deleted or moved before the file was actually restored. This action  
could occur as a result of MOVE DATA, DELETE VOLUME, AUDIT  
VOLUME FIX=YES, or reclamation processing of a copy storage pool volume  
while the restore was in progress.  
System Action: None.  
User Response: If this was an actual restore operation, check for messages  
indicating that files could not be restored because a copy storage pool volume was  
unavailable or offsite. Check to see if a move data, delete volume, audit volume, or  
reclamation process occurred for a copy storage pool while the restore was in  
progress. If either of these conditions existed, correct the situation and reissue the  
restore command.  
ANR1257W  
Storage pool backup skipping damaged file on volume volume name: Node node  
name, Type file type, File space filespace name, File name file name.  
Explanation: During storage pool backup, a file is encountered that was  
previously found to be damaged. If this file is part of an aggregate, the entire  
aggregate was previously marked damaged, possibly because an integrity error was  
detected for some other file within the aggregate.  
System Action: The damaged file will not be backed up.  
User Response: Audit the indicated volume with FIX=NO to verify that the file is  
damaged. The audit will reset the file status if the file is found to be undamaged  
during the audit. If the file is part of an aggregate, the audit will reset the aggregate  
status if the entire aggregate is found to be undamaged. If this file has previously  
been backed up to a copy storage pool, you can also attempt to restore damaged  
files using the RESTORE STGPOOL command.  
Tivoli Storage Manager Messages  
203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1258W  
ANR1259W  
ANR1260W  
Files on volume volume name needed for move data cannot be accessed - access  
mode is unavailableor offsite.  
Explanation: During a move data operation on an offsite volume, files on a  
storage pool volume cannot be copied because of the volume’s access mode.  
System Action: The server continues move data processing, but one or more files  
were not moved from the offsite volume.  
User Response: If the specified volume can be made available, use the UPDATE  
VOLUME command to change the access mode for the volume and reissue the  
MOVE DATA command.  
Files on volume volume name needed for offsite reclamation cannot be accessed  
- access mode is unavailableor offsite.  
Explanation: During reclamation processing of an offsite volume, files on a  
storage pool volume cannot be copied because of the volume’s access mode.  
System Action: The server continues reclamation, but one or more files were not  
moved from an offsite volume, which prevents it from being reclaimed.  
User Response: If the specified volume can be made available, use the UPDATE  
VOLUME command to change the access mode for the volume and initiate  
reclamation again by updating the reclamation threshold for the copy storage pool.  
Volume volume name contains one or more damaged, primary files.  
Explanation: This message is issued during RESTORE STGPOOL processing.  
The indicated volume contains one or more primary, noncached files that have  
previously been found to be damaged.  
System Action: If this is not a preview operation, the restore processing attempts  
to restore the damaged files from copies located in a copy storage pool. If this is a  
preview operation, no system action is taken.  
User Response: You can take the following actions:  
Issue the QUERY CONTENT command with DAMAGED=YES to obtain a list  
of damaged files on the indicated volume.  
Audit the indicated volume with FIX=NO to verify that the files are damaged;  
the audit will reset the status of any files that are found to be undamaged during  
the audit.  
If this message was issued during a restore preview operation, attempt to restore  
the damaged files using the RESTORE STGPOOL command.  
Audit the indicated volume with FIX=YES to delete the damaged files from the  
database.  
204  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1263I  
ANR1264I  
ANR1265E  
command: Processing completed successfully.  
Explanation: The background process to service the command command has  
completed successfully.  
System Action: Processing for the command completes. Statistics on the number  
and type of objects moved, together with the total number of bytes copied, are  
displayed on the server console following this message.  
User Response: None.  
Command: Processing canceled before completion.  
Explanation: The background process to service the command command has been  
canceled with the CANCEL PROCESS command.  
System Action: Processing for the command command ends. Statistics on the  
number and type of objects moved, together with the total number of bytes copied,  
are displayed on the server console following this message.  
User Response: None.  
Salvage volume command: Processing terminated abnormally - error accessing  
data storage.  
Explanation: The server encountered an internal error in accessing data storage  
while executing a salvage volume operation.  
System Action: The operation is ended and server operation continues.  
User Response: Use the QUERY ACTLOG command to examine messages prior  
to this error to determine the cause of the data storage failure. If you find and  
resolve the error, retry the operation. If you cannot find the error, contact your  
service representative for assistance in resolving the problem.  
ANR1266E  
Salvage volume command: Processing terminated abnormally - volume not a  
storage pool volume.  
Explanation: The server encountered an internal error in accessing data storage  
while executing a salvage volume operation.The error occurred because an attempt  
has been made to access a volume that was not a storage pool volume.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Issue the command with a valid volume name.  
Tivoli Storage Manager Messages  
205  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1267I  
ANR1268I  
ANR1269I  
ANR1270I  
Salvage volume command: Processed number volume(s).  
Explanation: The background process to service the command Salvage volume  
command inspected number input volumes.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
Salvage volume command: Recovered number byte(s).  
Explanation: The background process to service the command Salvage volume  
command recovered number bytes worth of data.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
Salvage volume command: Recovered number file(s).  
Explanation: The background process to service the command Salvage volume  
command recovered number files.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
Salvage volume command: File (internal file identifierinternal file identifier)  
recovered.  
Explanation: The background process to service the command Salvage volume  
command recovered a file. The new file was given a new, system generated name  
based on the internal file identifier and the name of the volume from which the file  
was recovered. The internal file identifier is the identifier by which the file was  
known to the server before the file was deleted.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
ANR1271I  
Salvage volume command: * number bytes recovered from volume volume.  
Explanation: The background process to service the command Salvage volume  
command recovered a file from the volume volume. The number of bytes recovered  
from the volume is listed.  
206  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
ANR1272I  
Salvage volume command: * File is complete -- it began and ended on volume  
volume.  
Explanation: The background process to service the command Salvage volume  
command recovered a file from the volume volume. The file was completely  
contained on volume.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
ANR1273I  
Salvage volume command: * File is incomplete -- it began on volume volume but  
did not end.  
Explanation: The background process to service the command Salvage volume  
command recovered a file from the volume volume. The file was not completely  
contained on volume. Although the file began on this volume, it spanned out to a  
different volume.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
ANR1274I  
Salvage volume command: * File is incomplete -- it ended on volume volume but  
did not begin there.  
Explanation: The background process to service the command Salvage volume  
command recovered a file from the volume volume. The file was not completely  
contained on volume. Although the file ended on this volume, it spanned in from a  
different volume.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
ANR1275I  
Salvage volume command: * File is incomplete -- it did not began or end on  
volume volume.  
Explanation: The background process to service the command Salvage volume  
command recovered a file from the volume volume. The file was not completely  
contained on volume. It spanned in from one volume and spanned out to a another.  
Tivoli Storage Manager Messages  
207  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Salvage processing for the command completes. Server operation  
continues.  
User Response: None.  
ANR1276E  
Command: Process terminated - sufficient memory is not available.  
Explanation: During salvage processing, not enough server memory is available.  
System Action: The salvage process ends.  
User Response: If necessary, make more memory available to the server, and then  
reissue the salvage command.  
ANR1277E  
Command: Process terminated - the default management class in the active  
policy set in policy domain domain name does not contain an archive copy  
group. Unable to continue with salvage.  
Explanation: The background process to service the command Salvage volume  
command was unable to recover any files because the default management class in  
the active policy set in policy domain does not contain an archive copy group.  
System Action: The salvage process ends.  
User Response: Add an archive copy group to the default management class in the  
active policy set of the specified domain, and then reissue the salvage command.  
ANR1278I  
Occupancy is incorrect for storage pool storage pool name. Occupancy is being  
reset.  
Explanation: The server has detected incorrect occupancy information.  
System Action: The server recalculates the occupancy value based on current  
storage pool information.  
User Response: None.  
ANR1279I  
Occupancy is incorrect for volume name volume name. Occupancy is being  
reset.  
Explanation: The server has detected incorrect occupancy information.  
System Action: The server recalculates the occupancy value based on current  
sequential volume information.  
User Response: None.  
208  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1280E  
Command: Process process ID terminated - transaction aborted.  
Explanation: During backup processing, the server detected an error while  
attempting to commit a transaction. This message should be preceded by other  
messages that give additional information about the failed transaction.  
System Action: The indicated backup process ends.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction.  
ANR1281E  
Command: Process process ID terminated - transaction aborted.  
Explanation: During restore processing, the server detected an error while  
attempting to commit a transaction. This message should be preceded by other  
messages that give additional information about the failed transaction.  
System Action: The indicated restore process ends.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction.  
ANR1282I  
ANR1283I  
ANR1300I  
Logical occupancy is incorrect for storage pool storage pool name. Logical  
occupancy is being reset.  
Explanation: The server has detected incorrect logical occupancy information.  
System Action: The server recalculates the logical occupancy value based on  
current storage pool information.  
User Response: None.  
File count is incorrect for storage pool storage pool name - file count is being  
reset.  
Explanation: The server has detected an incorrect count of the number of files  
within this storage pool.  
System Action: The server will correct this information.  
User Response: None.  
VARY ONLINE command initiated for disk volume volume name.  
Explanation: A VARY ONLINE command has caused a vary-on process to be  
started for the volume specified.  
System Action: The volume is varied online.  
User Response: None.  
Tivoli Storage Manager Messages  
209  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1301I  
ANR1302E  
ANR1303E  
ANR1304E  
VARY OFFLINE command initiated for disk volume volume name.  
Explanation: A VARY OFFLINE command has caused a vary-off process to be  
started for the volume specified.  
System Action: The volume is varied offline.  
User Response: None.  
Disk volume volume name is already online.  
Explanation: A VARY ONLINE command specified a volume that was already  
online.  
System Action: None.  
User Response: None.  
Disk volume volume name is already offline.  
Explanation: A VARY OFFLINE command specified a volume that was already  
offline.  
System Action: None.  
User Response: None.  
Disk volume volume name is currently in use.  
Explanation: A VARY OFFLINE command specified a volume that is currently in  
use and cannot be varied offline at this time.  
System Action: None.  
User Response: Try the command again at a later time, or attempt to determine  
how it is currently being used and free it.  
ANR1305I  
Disk volume volume name varied online.  
Explanation: The specified volume has been varied online as the result of a  
VARY ONLINE command.  
System Action: None.  
User Response: None.  
ANR1306I  
Disk volume volume name varied online (read-only).  
Explanation: The specified volume has been varied online in read-only mode as  
the result of a VARY ONLINE command.  
210  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR1307I  
Disk volume volume name varied offline.  
Explanation: The specified volume has been varied offline as the result of a  
VARY OFFLINE command.  
System Action: None.  
User Response: None.  
ANR1310E  
Vary-on failed for disk volume volume name - insufficient memory.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but sufficient memory is not available to process the command.  
System Action: The volume is not varied online.  
User Response: Reissue the command at a later time, or make more memory  
available to the server.  
ANR1311E  
ANR1312E  
ANR1313E  
Vary-on failed for disk volume volume name - unable to access disk device.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but the server is unable to access the disk.  
System Action: The volume is not varied online.  
User Response: Attempt to determine the cause of the inability to access the  
volume and correct the problem.  
Vary-on failed for disk volume volume name - error reading disk.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified but the server encounters an error reading the disk.  
System Action: The volume is not varied online.  
User Response: Attempt to determine the cause of the read error and correct the  
problem.  
Vary-on failed for disk volume volume name - unsupported block size (block  
size).  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but the volume is formatted with a block size that cannot be used.  
System Action: The volume is not varied online.  
Tivoli Storage Manager Messages  
211  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reformat the disk with a block size that is an evenly divisible by  
4096.  
ANR1314E  
Vary-on failed for disk volume volume name - reduced capacity (was count  
blocks, now count blocks.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but the size of the volume does not match the size expected.  
System Action: The volume is not varied online.  
User Response: Restore the volume or otherwise correct the disk volume size, and  
reissue the command.  
ANR1315E  
ANR1316E  
ANR1320W  
Vary-on failed for disk volume volume name - invalid label block.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but the label block of the volume is invalid or cannot be read.  
System Action: The volume is not varied online.  
User Response: Restore or reformat the disk volume.  
Vary-on failed for disk volume volume name - internal error detected.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but fails due to an internal server error.  
System Action: The volume is not varied online.  
User Response: Contact your service representative.  
Vary-on not possible for disk volume volume name - access state is  
unavailable.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but the status of the volume is unavailable.  
System Action: The volume is not varied online.  
User Response: If necessary, use the UPDATE VOLUME command to change the  
status of the volume, and reissue the command.  
ANR1321W  
Vary-on not possible for disk volume volume name - access state is destroyed.  
Explanation: A VARY ONLINE command has been issued for the disk volume  
specified, but the status of the volume is destroyed.  
System Action: The volume is not varied online.  
212  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If necessary, use the UPDATE VOLUME command to change the  
status of the volume, and reissue the command.  
ANR1340I  
Scratch volume volume name is now defined in storage pool storage pool name.  
Explanation: The scratch volume specified has been added to the storage pool  
shown.  
System Action: None.  
User Response: None.  
ANR1341I  
Scratch volume volume name has been deleted from storage pool storage pool  
name.  
Explanation: The scratch volume specified is no longer in use and has been  
removed from the indicated storage pool.  
System Action: None.  
User Response: None.  
ANR1342I  
Scratch volume volume name is now pending - volume will be deleted from  
storage pool storage pool name after the reuse delay period for this storage pool  
has elapsed.  
Explanation: All files have been deleted from the indicated scratch volume. The  
volume will not be removed from the storage pool until the reuse delay time period  
for the indicated storage pool has elapsed. If the storage pool does not have a reuse  
tdelay specified, the indicated volume was emptied after it had been requested by  
another process. It will be in the full or filling state if the process places more data  
on the tape, or it will be removed from the storage pool after it is no longer  
required.  
System Action: None.  
User Response: None.  
ANR1343I  
Unable to delete scratch volume volume name.  
Explanation: A scratch volume cannot be deleted from the server and returned to  
scratch at this time because all the locks have not be released. A number of retries  
have been attempted.  
System Action: None  
User Response: The scratch volume will be automatically deleted when the server  
is restarted. Or, you may manually delete this volume later, using the DELETE  
VOLUME command.  
Tivoli Storage Manager Messages  
213  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1344I  
Volume volume name cannot be reused, remove from server storage.  
Explanation: A volume that was full and is now empty cannot be reused by the  
server due to the WORM (Write Once - Read Many) characteristics of the media.  
System Action: The volume will have a state where the access mode is  
READONLY, the status is FULL and the percent utilized is 0.0. The volume is  
considered empty for storage pool occupancy and utilization fields.  
User Response: If the volume is in a library, it must first be removed using the  
CHECKOUT LIBVOLUME command prior to manually deleting the volume. Use  
the DELETE VOLUME command to remove the volume from server storage.  
ANR1360I  
ANR1361I  
ANR1362I  
ANR1363I  
Output volume volume name opened (sequence number sequence number).  
Explanation: During a sequential data operation, the volume specified has been  
opened for output as the volume number shown.  
System Action: None.  
User Response: None.  
Output volume volume name closed.  
Explanation: During a sequential data operation, the volume specified has been  
closed because the export or dump is complete.  
System Action: None.  
User Response: None.  
Output volume volume name closed (full).  
Explanation: During a sequential data operation, the volume specified has been  
closed because the volume is full.  
System Action: None.  
User Response: None.  
Input volume volume name opened (sequence number sequence number).  
Explanation: Because of a sequential data operation, the volume specified has  
been opened for input as the volume number shown.  
System Action: None.  
User Response: None.  
214  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1364I  
ANR1365I  
ANR1366W  
Input volume volume name closed.  
Explanation: During a sequential data operation, the volume specified has been  
closed because the operation is complete.  
System Action: None.  
User Response: None.  
Volume volume name closed (end reached).  
Explanation: During a sequential data operation, the volume specified has been  
closed because processing of the volume is complete.  
System Action: None.  
User Response: None.  
Input volume volume name contains an invalid identifier.  
Explanation: During a sequential data operation, the volume specified has been  
mounted but contains an invalid identifier.  
System Action: The volume is not used.  
User Response: Make sure you specified the correct volume for the operation. If a  
LOADDB operation was being performed on MVS, the command syntax may be  
specified by using a ddname or by specifying a device class name. You must use the  
same method that was used when the data base was originally dumped. If you did  
not, this error message will be displayed. Try loading the data base by using the  
other method of syntax (ddname).  
ANR1367W  
Import volume volume name was written by a different export process.  
Explanation: During an IMPORT operation, the volume specified has been  
mounted but contains an export identifier that does not match the import process.  
System Action: The volume is not used.  
User Response: Supply a volume created by the proper export process.  
ANR1368W  
Input volume volume name contains sequence number sequence number; volume  
sequence number sequence number is required.  
Explanation: During a sequential data operation, the volume specified has been  
mounted but contains the wrong volume sequence number.  
System Action: The volume is not used.  
Tivoli Storage Manager Messages  
215  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Supply the volume with the proper sequence number. The volume  
history file can help you choose the correct volume.  
ANR1369E  
Input volume volume name contains Version 1 dump.  
Explanation: During a sequential data operation, the volume specified has been  
mounted but appears to contain a version 1 data base dump.  
System Action: The volume is not used. The operation is terminated.  
User Response: Make sure you specified the correct volume for the operation. A  
Version 1 database dump may not be loaded into a Version 2 server. The Version 1  
database dump must only be loaded into a Version 1 server.  
ANR1370E  
Insufficient number of mount points available in device class device class name.  
Explanation: During IMPORT or EXPORT processing, the server cannot allocate  
sufficient mount points for the device class specified. The device class associated  
with the EXPORT or IMPORT drive only has a mount limit of one. The operation  
needs to read or write file data from or to the same device class because file data is  
being imported or exported.  
System Action: The IMPORT or EXPORT command is ended and server operation  
continues.  
User Response: Make more mount points available.  
ANR1400W  
Mount request denied for volume volume name - mount canceled.  
Explanation: The volume shown cannot be mounted because the mount request  
has been canceled.  
System Action: The volume is not mounted.  
User Response: None.  
ANR1401W  
Mount request denied for volume volume name - mount failed.  
Explanation: The volume shown cannot be mounted because the mount request  
cannot be completed successfully. Possible reasons include, an error in device  
specifications to the server or the mount request timed out.  
System Action: The volume is not mounted.  
User Response: If the device specifications (DEFINE DEVCLASS and so forth)  
are in error, correct them and reissue the command that requested the volume to be  
mounted.  
216  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1402W  
ANR1403W  
Mount request denied for volume volume name - volume unavailable.  
Explanation: The volume shown cannot be mounted because it is not available.  
System Action: The volume is not mounted.  
User Response: None.  
Scratch volume mount request denied - mount canceled.  
Explanation: A scratch volume cannot be mounted because the mount request has  
been canceled.  
System Action: The scratch volume is not mounted.  
User Response: None.  
ANR1404W  
Scratch volume mount request denied - mount failed.  
Explanation: A scratch volume cannot be mounted because the mount request  
cannot be completed successfully. Possible reasons include, an error in device  
specifications to the server or the mount request timed out.  
System Action: The scratch volume is not mounted.  
User Response: If the device specifications (for example, DEFINE DEVCLASS)  
are in error, correct them and reissue the command that requested the volume to be  
mounted.  
ANR1405W  
Scratch volume mount request denied - no scratch volume available.  
Explanation: A scratch volume cannot be mounted because no scratch volume is  
available.  
System Action: The scratch volume is not mounted.  
User Response: None.  
ANR1409W  
Volume command already in use - skipped.  
Explanation: During an export or database backup, a volume cannot be used  
because it is already defined in a storage pool, or has been previously used by an  
export or database backup operation (as recorded in the volume history) or is in use  
by another process.  
System Action: The operation continues and the volume is skipped.  
Tivoli Storage Manager Messages  
217  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the QUERY VOLUME command to display the names of  
volumes that are defined to server storage pools. Use the QUERY VOLHISTORY  
command to display the names of volumes that have been used for export or  
database backup operations.  
ANR1410W  
ANR1411W  
Access mode for volume volume name now set to unavailable.  
Explanation: The status of the volume shown has been set to unavailable.  
System Action: None.  
User Response: None.  
Access mode for volume volume name now set to read-onlydue to write error.  
Explanation: Because of an unrecoverable write error on the volume shown, the  
status of the volume has been set to read-only.  
System Action: None.  
User Response: None.  
ANR1412W  
ANR1413W  
ANR1414W  
Volume volume name access mode is unavailable.  
Explanation: At server startup, the status of the indicated volume is unavailable.  
System Action: None.  
User Response: None.  
Volume volume name access mode is read-only.  
Explanation: At server startup, the status of the indicated volume is read-only.  
System Action: None.  
User Response: None.  
Volume volume name access mode is read-onlydue to previous write error.  
Explanation: At server startup, the status of the indicated volume is read-only due  
to an unrecoverable write error, or because an administrator used the UPDATE  
VOLUME command to set the volume access mode to read-only.  
System Action: None.  
User Response: None.  
218  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1415W  
ANR1416W  
ANR1417W  
Volume volume name access mode is destroyed.  
Explanation: At server startup, the status of the indicated volume is destroyed.  
System Action: None.  
User Response: None.  
Volume volume name access mode is offsite.  
Explanation: At server startup, the status of the indicated volume is offsite.  
System Action: None.  
User Response: None.  
Access mode for volume volume name now set to read-onlydue to excessive  
read error.  
Explanation: Because of an numerous read errors on the volume shown, the status  
of the volume has been set to read-only.  
System Action: None.  
User Response: Use QUERY VOLUME FORMAT=DETAILED for the volume to  
view the access mode and number of read errors. You may want to use the MOVE  
DATA command to move the retrievable data from this volume to another volume.  
For the damaged files, use the RESTORE VOLUME command to restore a readable  
copy of the file to the storage pool.  
ANR1420W  
Read access denied for volume volume name - volume access mode =  
unavailable.  
Explanation: An attempt to access the named volume for reading fails because the  
volume status is unavailable.  
System Action: The volume is not used for read access.  
User Response: None.  
ANR1421W  
Read access denied for volume volume name - volume offline.  
Explanation: An attempt to access the named volume for reading failed because  
the volume is offline.  
System Action: The volume is not used.  
User Response: None.  
Tivoli Storage Manager Messages  
219  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1422W  
Read access denied for volume volume name - volume access mode = offsite.  
Explanation: An attempt to access the named volume for reading failed because  
the volume status is offsite.  
System Action: The volume is not used for read access.  
User Response: None.  
ANR1423W  
Scratch volume volume name is empty but will not be deleted - volume access  
mode is offsite.  
Explanation: The named scratch volume is empty but will not be deleted at this  
time because the access mode is offsite.  
System Action: The volume is not deleted.  
User Response: After bringing the volume onsite, change the access mode to  
read-only so the volume will be deleted.  
ANR1424W  
Read access denied for volume volume name - volume access mode =  
destroyed.  
Explanation: An attempt to access the named volume for reading failed because  
the volume status is destroyed.  
System Action: The volume is not used for read access.  
User Response: None.  
ANR1425W  
Scratch volume volume name is empty but will not be deleted - volume state is  
mountablenotinlib.  
Explanation: The named scratch volume is empty but will not be deleted at this  
time because the state of the volume is MOUNTABLENOTINLIB.  
System Action: The volume is not deleted.  
User Response: When the volume is moved by MOVE MEDIA  
WHERESTATE=MOUNTABLENOTINLIB, the scratch empty volume is deleted.  
ANR1430W  
Retrieval request denied for storage pool storage pool name - access mode =  
unavailable.  
Explanation: An attempt was made to retrieve a file from the storage pool shown,  
but the access mode of the storage pool is unavailable.  
System Action: The file is not retrieved from this storage pool. If possible, the file  
is retrieved from another storage pool.  
220  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Consider changing the access mode for the storage pool.  
ANR1431E  
An error occurred while writing to side A of volume volume name. An attempt  
will be made to write to side B of this volume.  
Explanation: An error occurred while writing to side A of a two-sided volume.  
System Action: No additional data will be written to side A of this volume. Any  
remaining space on side A will not be used. An attempt will be made to use the  
reverse side (side B) of the volume.  
User Response: None required if the side B can be used successfully. However,  
the administrator should investigate the cause of the error and may want to move  
data from this volume.  
ANR1432I  
ANR1433I  
ANR1434W  
Updating device configuration information to defined files.  
Explanation: The server is updating device configuration information for the files  
or data sets specified with the DEVCONFIG option in the server options file.  
System Action: Server operation continues.  
User Response: None.  
Device configuration information successfully written to file name.  
Explanation: Device configuration information was successfully written to the file  
specified.  
System Action: Server operation continues.  
User Response: None.  
No files have been identified for automatically storing device configuration  
information.  
Explanation: The server is unable to automatically update device configuration  
file. No files were identified using the DEVCONFIG option in the server options  
file.  
System Action: Server operation continues.  
User Response: If you would like to have the server automatically record device  
configuration information to assist in server recovery, use the DEVCONFIG option  
in the server options file to specify where device configuration information should  
be written. If you update the options file, halt and then restart the server so the  
changes can take effect.  
Tivoli Storage Manager Messages  
221  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1435E  
ANR1436E  
ANR1437E  
Server could not write device configuration information to devconfig file name.  
Explanation: While attempting to write device configuration information to  
defined files, the server cannot write to the file name specified.  
System Action: The server cannot write device configuration information to the  
specified file.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated and that there is sufficient space in the  
file system for the file. On MVS, make sure that the data set has been allocated and  
that the server has authority to write to the data set. After the problem has been  
corrected, use the BACKUP DEVCONFIG command to write device configuration  
information to the file.  
Device configuration file devconfig file name cannot be opened.  
Explanation: While attempting to write device configuration information to device  
configuration files, the server cannot open the file name specified.  
System Action: The server does not write device configuration information to the  
file specified.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated and that there is sufficient space in the  
file system for the file. On MVS, make sure that the data set has been allocated and  
that the server has authority to write to the data set. After the problem has been  
corrected, use the BACKUP DEVCONFIG command to write device configuration  
information to the file.  
No device configuration files could be used.  
Explanation: The server attempts to read device configuration information from  
defined files and cannot open any of the files.  
System Action: The operation is ended.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Ensure that the defined device  
configuration files have been created. If you can start the server, you can create the  
files by using the BACKUP DEVCONFIG command. If you cannot start the server,  
you will need to create a device configuration file by editing the file and adding the  
appropriate DEFINE commands for the device class, drive, and library definitions.  
The contents and requirements for this file are described in the Administrators  
Guide. Make sure that the server has proper authority to read from the defined  
device configuration files.  
222  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1438W  
ANR1439E  
ANR1440I  
Skipping device configuration file: devconfig file name.  
Explanation: While attempting to read device configuration information from a  
defined device configuration file, the server encounters problems in processing the  
definitions included in the file.  
System Action: The specified file is skipped, and the next one specified in the  
server options file will be used.  
User Response: Examine error messages that may have been displayed prior to  
this message to understand why the file could not be used. When you can start the  
server again, you can refresh this file by using the BACKUP DEVCONFIG  
command.  
Allocate prohibited - transaction failed.  
Explanation: While attempting to preallocate storage on a storage pool, the server  
detected that the transaction for this operation has previously failed. This error may  
occur when a large file is selected for backup and the client did not properly  
estimate the file size. There may not be enough space in the storage pool for the  
file.  
System Action: An internal error is reported by the server and the operation being  
performed is ended.  
User Response: Examine error messages that may have been displayed prior to  
this message for more information.  
All drives in use. Process process number being preempted by higher priority  
operation.  
Explanation: When a high priority operation attempted to find an available drive,  
all the drives were in use. To make a drive available for this operation, the indicated  
process is being cancelled by the system.  
System Action: The lower priority process is cancelled to make a mount point  
(drive) available.  
User Response: When a drive again becomes available, restart the process that  
was cancelled. If the process was a migration or reclamation process, it will be  
automatically restarted when needed. If this message appears frequently, you may  
want to increase the number of drives available. See the MOUNTLIMIT parameter  
on the UPDATE DEVCLASS command.  
Tivoli Storage Manager Messages  
223  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1441I  
Volume volume name is in use. Process process number being preempted by  
higher priority operation.  
Explanation: When a high priority operation attempted to use a volume, it was in  
use. To make a volume available for this operation, the indicated process is being  
cancelled by the system.  
System Action: The lower priority process is cancelled to the volume available.  
User Response: Restart the process that was cancelled. It will wait until the higher  
priority process is finished with the volume. If the cancelled process was a  
migration or reclamation process, it will be automatically restarted when needed.  
ANR1450E  
ANR1451E  
ANR1452E  
ANR1453E  
command name: Invalid command script name: command script name.  
Explanation: An invalid script name was specified for a DEFINE, UPDATE, or  
DELETE SCRIPT command.  
System Action: The operation fails.  
User Response: Reenter the command specifying a valid command name.  
command name: Invalid command: command.  
Explanation: An invalid command was specified for a DEFINE, UPDATE, or  
DELETE SCRIPT command.  
System Action: The operation fails.  
User Response: Reenter the command specifying a valid server command.  
command name: Invalid line number: line number.  
Explanation: An invalid line number was specified for a DEFINE, UPDATE, or  
DELETE SCRIPT command.  
System Action: The operation fails.  
User Response: Reenter the command specifying a valid line number.  
command name: Command script command script name already exists.  
Explanation: The script name specified in a DEFINE SCRIPT command already  
exists.  
System Action: The operation fails.  
User Response: Reenter the command specifying a different command name.  
224  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1454I  
ANR1455E  
ANR1456I  
ANR1457I  
ANR1458I  
command name: Command script command script name defined.  
Explanation: The script name specified in a DEFINE SCRIPT command was  
successfully defined.  
System Action: None  
User Response: None  
command name: Command script command script name does not exist.  
Explanation: The script name specified in a DEFINE, UPDATE, or DELETE  
SCRIPT command does not exist.  
System Action: The operation fails.  
User Response: Reenter the command specifying a different command name.  
command name: Command script command script name updated.  
Explanation: The script name specified in an UPDATE SCRIPT command was  
successfully updated.  
System Action: None  
User Response: None  
command name: Command script command script name deleted.  
Explanation: The script name specified in a DELETE COMMAND command was  
successfully deleted.  
System Action: None  
User Response: None  
command name: Line line number was deleted from command script command  
script name.  
Explanation: The specified line number was deleted from the command script as a  
result of a DELETE SCRIPT command.  
System Action: None  
User Response: None  
Tivoli Storage Manager Messages  
225  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1459E  
command name: Command script command script name, line line number does  
not exist.  
Explanation: The line in command script name specified in a UPDATE, or  
DELETE SCRIPT command does not exist.  
System Action: The operation fails.  
User Response: Reenter the command specifying a different line number.  
ANR1460I  
command name: Command script command script name copied to new command  
script name.  
Explanation: The specified command script was copied to a new script with the  
COPY SCRIPT command.  
System Action: None  
User Response: None  
ANR1461I  
ANR1462I  
ANR1463E  
command name: Executing command script command script name.  
Explanation: The specified command script is being executed as a result of a  
RUN command.  
System Action: None  
User Response: None  
command name: Command script command script name completed successfully.  
Explanation: The specified command script, started with a RUN command, has  
successfully completed.  
System Action: None  
User Response: None  
command name: Command script command script name completed in error.  
Explanation: The specified command script, started with a RUN command,  
encountered errors.  
System Action: Part or all of the command lines in the script ended in error.  
Command processing is terminated.  
User Response: Examine the messages preceeding this message to determine the  
cause of the error. Correct the command script and reissue the command.  
226  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1464E  
command name: Command script command script name, line line number,  
parameter parameter number was not specified: command line.  
Explanation: All parameters required to execute a command script were not  
specified in the RUN command.  
System Action: The command fails.  
User Response: Reenter the RUN command specifying all required parameters.  
ANR1465E  
command name: Command script command script name, line line number,  
parameter is invalid: command line.  
Explanation: An invalid parameter was encountered in a command script.  
System Action: The command fails.  
User Response: Correct the script definition and reexecute the RUN command.  
ANR1466I  
command name: Command script command script name, Line line number :  
command line.  
Explanation: The specified line for the command script is being executed. The  
contects of the line being executed are displayed.  
System Action: None  
User Response: None  
ANR1467E  
command name: Command script command script name, did not end in a  
non-continued line command line.  
Explanation: The specified command script did not end in a line that had no  
continuation character (-).  
System Action: The command fails.  
User Response: Correct the specified script so that it ends in a line that is not  
continued to the next line.  
ANR1468E  
command name: Command script command script name, continued line is too  
long  
Explanation: The specified command script with continuation lines is too long to  
be executed.  
System Action: The command fails.  
User Response: Correct the specified command script so that it is shorter.  
Tivoli Storage Manager Messages  
227  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1469E  
command name: Command script command script name, Line line number is an  
INVALID command : command line.  
Explanation: The specified line for the command script is not a valid server  
command. This message is displayed when a RUN command is executed with the  
PREVIEW=YES parameter specified.  
System Action: Command Preview processing fails  
User Response: Correct the script and reenter the RUN command.  
ANR1470I  
command name: Command script command script name completed successfully  
(PREVIEW mode).  
Explanation: The specified command script, started with a RUN command, has  
successfully completed.  
System Action: None.  
User Response: None.  
ANR1471E  
command name: Command script command script name completed in error  
(PREVIEW mode).  
Explanation: The specified command script, started with a RUN command,  
encountered errors.  
System Action: Part or all of the command lines in the command script ended in  
error. Command processing is terminated.  
User Response: Examine the messages preceeding this message to determine the  
cause of the error. Correct the script and reissue the command.  
ANR1472I  
command name: Command script command script name renamed to new  
command script name.  
Explanation: The specified command script was renamed with the RENAME  
SCRIPT command.  
System Action: None.  
User Response: None.  
ANR1473E  
command name: A command line cannot be specified when the FILE=  
parameter is used.  
Explanation: The FILE= parameter was specified in the DEFINE SCRIPT  
command AND a command line was also specified for the SCRIPT. When the  
FILE= parameter is specified, a command line cannot be specified.  
228  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails.  
User Response: Reenter the command without the command line OR the FILE=  
parameter.  
ANR1474E  
command name: A line number cannot be specified when the FILE= parameter  
is used.  
Explanation: The FILE= parameter was specified in the DEFINE SCRIPT  
command AND a line number was also specified for the SCRIPT. When the FILE=  
parameter is specified, a line number cannot be specified.  
System Action: The command fails.  
User Response: Reenter the command without the line number OR the FILE=  
parameter.  
ANR1475E  
command name: File file name could not be opened.  
Explanation: A filename was specified in a command but the specified file could  
not be opened by the server.  
System Action: The command fails.  
User Response: Examine any messages that might appear prior to this one in the  
activity log to determine if the error can be found. If the file was to exist for use by  
the command, ensure that the file does exists and that the server has proper  
authority to access the file. If the file was to be created by the command, ensure  
that the filesystem has sufficient space and that the server has authority to create the  
file in the location specified.  
ANR1476E  
command name: File file name contains no data.  
Explanation: The FILE= parameter was specified in a command but the specified  
file did not contain script command lines.  
System Action: The command fails.  
User Response: Add script command lines to the file or specify another file and  
reenter the command.  
ANR1477E  
command name: The OUTPUTFILE parameter may only be specified when  
FORMAT=RAW or FORMAT=MACRO is specified.  
Explanation: The OUTPUTFILE parameter was specified in a QUERY SCRIPT  
command but the FORMAT parameter did not specify RAW or MACRO output.  
When outputting the QUERY to a file, you MUST specify RAW or MACRO output  
format.  
Tivoli Storage Manager Messages  
229  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails.  
User Response: Reenter the command specifying the proper value for the  
FORMAT parameter or do not specify the OUTPUTFILE parameter.  
ANR1478E  
command name: Error writing to file file name.  
Explanation: An error was encountered while writing to the file specified.  
System Action: The command fails.  
User Response: Examine any messages that might appear prior to this one in the  
activity log to determine if the error can be found. Ensure that the filesystem has  
sufficient space and that the server has authority to create the file in the location  
specified.  
ANR1479I  
ANR1480E  
ANR1481E  
command name: Query output was written to file file name.  
Explanation: The output from the specified query was successfully written to the  
specified file.  
System Action: The command completes successfully.  
User Response: None.  
command name: Description text is too long.  
Explanation: The specified description text is too long for a command that allows  
description text to be specified.  
System Action: The command fails.  
User Response: Reenter the command specifying a shorter description.  
command name: A command line or description must be specified.  
Explanation: An UPDATE SCRIPT command was specified with out a command  
line (script line) or description text.  
System Action: The command fails.  
User Response: Reenter the command specifying a command line or description  
text.  
ANR1482I  
command name: Found label statement label on line line number and continuing.  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate that the target label for a GOTO statement was found.  
System Action: Command processing continues.  
230  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR1483I  
command name: Line line number condition IF(condition) is NOT true -  
statement is skipped.  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate that the a return code condition check failed and the IF(..) statement is  
skipped.  
System Action: Command processing continues.  
User Response: None.  
ANR1484I  
command name: Line line number condition IF(condition) is TRUE - statement  
will be executed.  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate that the a return code condition check succeeded and the IF(..) statement  
is executed.  
System Action: Command processing continues.  
User Response: None.  
ANR1485I  
ANR1486I  
ANR1487I  
command name: Ending SCRIPT with EXIT statement on line line number.  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate that an EXIT statement was encountered and SCRIPT termination will  
end.  
System Action: The SCRIPT command ends.  
User Response: None.  
command name: Executing line line number GOTO label name.  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate that a GOTO statment was encountered and processing will skip to the  
named label.  
System Action: SCRIPT processing continues.  
User Response: None.  
command name: Command return code is symbolic return code (return code  
severity).  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate the return code that was returned from the latest command.  
Tivoli Storage Manager Messages  
231  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: SCRIPT processing continues.  
User Response: None.  
ANR1488E  
ANR1489E  
ANR1490W  
ANR1491E  
command name: Line line number condition IF(condition) is not a valid  
condition.  
Explanation: This message is issued if an IF() statement in a SCRIPT does not  
specify proper condition values.  
System Action: Command processing fails.  
User Response: Reenter the command using valid conditions for the IF()  
statement.  
command name: Line line number is a GOTO to a label (label name) that does  
not exist or is associated with a line prior to line line number.  
Explanation: This message is issued if a GOTO statment in a SCRIPT does not  
specify a label that exists in the SCRIPT, or that does exist but is associated with a  
line prior to the line that contains the GOTO statement.  
System Action: Command processing fails.  
User Response: Correct the SCRIPT definition and reenter the RUN command.  
command name: Command script command script name does not contain any  
commands.  
Explanation: The script name specified in a RUN command does not contain any  
commands.  
System Action: The RUN operation fails (has nothing to do).  
User Response: Server command Scripts that contain no commands will not  
execute. Add command lines to the Script and re-enter the RUN command.  
Server command scripts cannot be started from the server console.  
Explanation: A server command script RUN command was issued from the server  
console. Server command scripts cannot be started from the server console because  
they may require a long time complete and the server console should be available to  
control other server functions.  
System Action: The server ignores the command and continues processing.  
User Response: Start the server command script from an administrative client or  
schedule it for execution using the administrative command scheduler.  
232  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1492E  
command name: A loop has been detected in server command script RUN  
commands - command failed.  
Explanation: A server command script DEFINE or UPDATE command has  
created a situation where one or more scripts invoke each other in a loop that can  
cause the scripts to run idefinitely.  
System Action: The command fails to update the server command script.  
User Response: Server command scripts can invoke each other, but not in a  
fashion that causes a potential loop in their execution. Specify the scripts in a  
manner that does not cause them to invoke each other in a loop.  
ANR1493E  
Command: Administrator administrator name is not authorized to update or  
delete command script command script name.  
Explanation: The specified administrator has entered the indicated command, but  
this administrator does not have the proper authority necessary to update or delete  
this command script. If an administrator does not have system authority, they must  
have previously created or updated the script.  
System Action: The server does not process the command.  
User Response: Issue the command from a properly authorized administrator ID,  
or contact the administrator that created the script.  
ANR1494I  
ANR1496I  
ANR1497W  
command name: Command return code is numeric return code.  
Explanation: This message is issued during a RUN command (VERBOSE=YES)  
to indicate the numeric return code that was returned from the latest command.  
System Action: SCRIPT processing continues.  
User Response: None.  
Explanation: The ISSUE MESSAGE command with a severity indicator of  
INFORMATION was issued.  
System Action: Server operation continues.  
User Response: None.  
Explanation: The ISSUE MESSAGE command with a severity indicator of  
WARNING was issued.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
233  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR1498E  
ANR1499S  
ANR1500I  
ANR1501I  
Explanation: The ISSUE MESSAGE command with a severity indicator of  
ERROR was issued.  
System Action: Server operation continues.  
User Response: None.  
Explanation: The ISSUE MESSAGE command with a severity indicator of  
SEVERE was issued.  
System Action: Server operation continues.  
User Response: None.  
Policy domain domain name defined.  
Explanation: In response to the DEFINE DOMAIN command, the policy domain  
domain name has been defined in the server database.  
System Action: Server operation continues.  
User Response: None.  
Policy domain domain name deleted.  
Explanation: In response to the DELETE DOMAIN command, the policy domain  
domain name has been deleted from the server database. All policy sets,  
management classes, copy groups, and schedules related to the domain have also  
been removed.  
System Action: Server operation continues.  
User Response: None.  
ANR1502I  
Policy domain domain name updated.  
Explanation: In response to the UPDATE DOMAIN command, the policy domain  
domain name has been updated in the server database.  
System Action: Server operation continues.  
User Response: None.  
234  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1503I  
Policy domain domain name copied to domain target domain.  
Explanation: In response to the COPY DOMAIN command, the policy domain  
domain name has been copied to a new policy domain named target domain. All  
policy sets, management classes, and copy groups are also copied to the target  
domain policy domain.  
System Action: Server operation continues.  
User Response: None.  
ANR1504I  
Command: No matching domains.  
Explanation: The server cannot find any policy domains with names that match  
the specification entered in the command command.  
System Action: Server operation continues.  
User Response: Reissue the command with a specification that matches an  
existing policy domain name. Use the QUERY DOMAIN command to obtain a list  
of the names of existing policy domains.  
ANR1510I  
ANR1511I  
ANR1512I  
Policy set set name defined in policy domain domain name.  
Explanation: In response to the DEFINE POLICYSET command, the policy set  
named set name has been defined in the policy domain named domain name in the  
server database.  
System Action: Server operation continues.  
User Response: None.  
Policy set set name deleted from policy domain domain name.  
Explanation: In response to the DELETE POLICYSET command, the policy set  
set name has been deleted from the policy domain domain name in the server  
database.  
System Action: Server operation continues.  
User Response: None.  
Policy set set name updated in policy domain domain name.  
Explanation: In response to the UPDATE POLICYSET command, the policy set  
set name has been updated in the policy domain domain name in the server  
database.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
235  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR1513I  
Policy set set name copied to set new set name in policy domain domain name.  
Explanation: In response to the COPY POLICYSET command, the policy set set  
name has been copied to the policy set new set name in the policy domain named  
domain name. All management classes and copy groups are also copied to the  
policy set new set name.  
System Action: Server operation continues.  
User Response: None.  
ANR1514I  
Policy set set name activated in policy domain domain name.  
Explanation: In response to the ACTIVATE POLICYSET command, the policy set  
set name has been activated in the policy domain domain name. All management  
class and copy group definitions in the policy set will be used by clients that start  
sessions after this command is committed. Clients that currently have sessions  
established with the server will use the policy definitions in the previously active  
policy set for the domain.  
System Action: The server replaces the active management class and copy group  
definitions for the policy domain with the definitions found in the specified policy  
set. These values are returned to client nodes that start a session with the server  
after this command is committed to the server database.  
User Response: None.  
ANR1515I  
Policy set set name validated in domain domain name (ready for activation).  
Explanation: This message may be displayed in response to a VALIDATE  
POLICYSET command. The policy set set name has been checked in the domain  
domain name to see if the management class and copy group definitions are  
adequate for activating the policy set. This message indicates that the policy set may  
be activated. Warning messages may be issued prior to this message if there are  
discrepancies in the policy set with respect to the set that is currently active in the  
policy domain.  
System Action: The server checks its definitions to determine the policy set’s  
qualifications for activation. The server does not activate the policy set.  
User Response: If you are satisfied with any warning messages that may have  
been issued prior to this message concerning any possible discrepancies in the  
policy set, issue the ACTIVATE POLICYSET command to activate the policy set in  
the policy domain. Otherwise, correct the discrepancies prior to activating the policy  
set. Before the ACTIVATE POLICYSET command is used to activate the policy set,  
use the validate command to check policy set contents.  
236  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1520I  
Management class class name defined in policy domain domain name, set set  
name.  
Explanation: In response to the DEFINE MGMTCLASS command, the  
management class named class name has been defined in the policy set set name  
belonging to the policy domain named domain name.  
System Action: Server operation continues.  
User Response: None.  
ANR1521I  
Management class class name deleted from policy domain domain name, set set  
name.  
Explanation: In response to a DELETE MGMTCLASS command, the  
management class named class name has been deleted from the policy set set name  
belonging to the policy domain domain name. All copy groups defined for the  
management class are also removed.  
System Action: Server operation continues.  
User Response: None.  
ANR1522I  
Management class class name updated in policy domain domain name, set set  
name.  
Explanation: In response to the UPDATE MGMTCLASS command, the  
management class named class name has been updated in the policy domain domain  
name, policy set set name.  
System Action: Server operation continues.  
User Response: None.  
ANR1523I  
Management class class name copied to class new class name in policy domain  
domain name, set set name.  
Explanation: In response to the COPY MGMTCLASS command, the management  
class named class name has been copied to a new management class named new  
class name in policy set set name belonging to policy domain domain name. All  
copy groups defined for management class class name are also copied to  
management class new class name.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
237  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1530I  
ANR1531I  
ANR1532I  
ANR1535I  
Backup copy group group name defined in policy domain domain name, set set  
name, management class class name.  
Explanation: In response to the DEFINE COPYGROUP command, a backup copy  
group named group name has been defined for the management class named class  
name in the policy set set name belonging to policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
Backup copy group group name deleted from policy domain domain name, set  
set name, management class class name.  
Explanation: In response to the DELETE COPYGROUP command, the backup  
copy group named group name has been deleted from the management class named  
class name in the policy set set name belonging to policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
Backup copy group group name updated in policy domain domain name, set set  
name, management class class name.  
Explanation: In response to the UPDATE COPYGROUP command, the backup  
copy group named group name has been updated in the management class named  
class name in the policy set set name belonging to policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
Archive copy group group name defined in policy domain domain name, set set  
name, management class class name.  
Explanation: In response to the DEFINE COPYGROUP command, an archive  
copy group named group name has been defined for the management class named  
class name in the policy set set name belonging to policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
238  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1536I  
ANR1537I  
ANR1538I  
Archive copy group group name deleted from policy domain domain name, set  
set name, management class class name.  
Explanation: In response to the DELETE COPYGROUP command, the archive  
copy group named group name has been deleted from the management class named  
class name in the policy set set name belonging to policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
Archive copy group group name updated in policy domain domain name, set set  
name, management class class name.  
Explanation: In response to the UPDATE COPYGROUP command, the archive  
copy group named group name has been updated in the management class named  
class name in the policy set set name belonging to policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
Default management class set to class name for policy domain domain name, set  
set name.  
Explanation: The default management class for the policy set set name in policy  
domain domain name has been set to the management class named class name.  
System Action: If this policy set is activated, clients use this management class for  
backup-archive processing by default, or if other management classes specified for  
binding do not exist in the policy set.  
User Response: None.  
ANR1550W  
Management class class name is NOT defined in policy set set name but IS  
defined in the ACTIVE policy set for domain domain name: files bound to this  
management class will be REBOUND to the default management class if/when  
this set is activated.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation processing, the  
server has found a management class named class name in the currently active  
policy set, but not defined in the policy set being validated or activated (set name).  
If policy set set name is activated, files bound to this management class in domain  
domain name are automatically rebound to the default management class in policy  
set set name.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
239  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If you do not want files to be rebound to the default management  
class, define a management class with the name specified in the message for the  
policy set. To define the proper copy group attributes, reference the management  
class definition in the ACTIVE policy set or copy the management class class name  
from the ACTIVE policy set to policy set set name using the COPY MGMTCLAS  
command.  
ANR1551W  
BACKUP copygroup group name in management class class name is NOT  
defined in policy set set name but is defined in the ACTIVE policy set for  
domain domain name: files bound to this management class will no longer be  
backed up if/when set name is activated.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation processing, the  
server has found a backup copy group named group name for management class  
class name in the currently active policy set, but the copy group is not defined for  
the management class in the policy set being validated or activated (set name). If  
policy set set name is activated, files bound to management class class name in  
domain domain name will no longer be eligible for backup processing.  
System Action: Server operation continues.  
User Response: If you want files bound to this management class to be eligible  
for backup processing, define an archive copy group for management class class  
name by using the DEFINE COPYGROUP command.  
ANR1552W  
ARCHIVE copygroup group name in management class class name is NOT  
defined in policy set set name but is defined in the ACTIVE policy set for  
domain domain name: files bound to this management class will no longer be  
archived if/when set name is activated.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation processing, the  
server has found an archive copy group named group name for management class  
class name in the currently active policy set, but the copy group is not defined for  
the management class in the policy set being validated or activated (set name). If  
policy set set name is activated, files bound to management class class name in  
domain domain name will no longer be eligible for archive processing.  
System Action: Server operation continues.  
User Response: If you want files bound to this management class to be eligible  
for archive processing, define an archive copy group for management class class  
name by using the DEFINE COPYGROUP command.  
240  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1553W  
ANR1554W  
ANR1555W  
DEFAULT Management class class name in policy set domain name set name  
does not have a BACKUP copygroup: files will not be backed up by default if  
this set is activated.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for policy set set  
name in policy domain domain name, the server has found that the default  
management class named class name does not have a backup copy group. This  
message warns the administrator that activation of this policy set results in client  
files not being backed up, unless they are bound to a management class (which has  
a copy group) other than the default.  
System Action: Server operation continues.  
User Response: To define a backup copy group for the management class, issue  
the DEFINE COPYGROUP command. To assign a different default management  
class for the domain, issue the ASSIGN DEFMGMTCLASS command. Take either  
action if you want files to be backed up by default.  
DEFAULT Management class class name in policy set domain name set name  
does not have an ARCHIVE copygroup: files will not be archived by default if  
this set is activated.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for policy set set  
name in policy domain domain name, the server has found that the default  
management class named class name does not have an archive copy group. This  
message warns the administrator that activation of this policy set will result in client  
files not being allowed archive processing unless they are bound to a management  
class (which has an archive copy group) other than the default.  
System Action: Server operation continues.  
User Response: To define a backup copy group for the management class, issue  
the DEFINE COPYGROUP command. To assign a different default management  
class for the domain, issue the ASSIGN DEFMGMTCLASS command. Take either  
action if you want files to be eligible for archive processing by default.  
The BACKUP copy group in management class management class name specifies  
a destination that does not refer to a defined storage pool: storage pool name. If  
this pool does not exist when policy set policy set name is activated, clients will  
fail when using this management class to backup files to the server.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for set name, the  
server has found a backup copy group destination that references an undefined  
storage pool named pool name. If this storage pool is undefined when the policy set  
Tivoli Storage Manager Messages  
241  
Download from Www.Somanuals.com. All Manuals Search And Download.  
is activated, backup or archive operations will fail for clients with files bound to the  
management class whose copy groups reference this pool.  
System Action: Server operation continues.  
User Response: To locate the copy groups that refer to the undefined storage pool,  
issue the QUERY COPYGROUP command. To change the destination to refer to an  
existing storage pool, issue the UPDATE COPYGROUP command. To define the  
storage pool, an authorized administrator can issue the DEFINE STGPOOL  
command.  
ANR1556W  
The ARCHIVE copy group in management class management class name  
specifies a destination that does not refer to a defined storage pool: storage pool  
name. If this pool does not exist when policy set policy set name is activated,  
clients will fail when using this management class to archive files to the server.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for set name, the  
server has found a archive copy group destination that references an undefined  
storage pool named pool name. If this storage pool is undefined when the policy set  
is activated, backup or archive operations will fail for clients with files bound to the  
management class whose copy groups reference this pool.  
System Action: Server operation continues.  
User Response: To locate the copy groups that refer to the undefined storage pool,  
issue the QUERY COPYGROUP command. To change the destination to refer to an  
existing storage pool, issue the UPDATE COPYGROUP command. To define the  
storage pool, an authorized administrator can issue the DEFINE STGPOOL  
command.  
ANR1557W  
The space management migration destination in management class management  
class name does not refer to a defined storage pool: storage pool name. If this  
pool does not exist when policy set policy set name is activated, clients will fail  
when using this management class to migrate space-managed files to the server.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for set name, the  
server has found a space management migration destination that references an  
undefined storage pool named pool name. If this storage pool is undefined when the  
policy set is activated, space management migration operations will fail for clients  
with files bound to the management class that references this pool.  
System Action: Server operation continues.  
User Response: To locate the management class that refers to the undefined  
storage pool, issue the QUERY MGMTCLASS command. To change the destination  
242  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to refer to an existing storage pool, issue the UPDATE MGMTCLASS command.  
To define the storage pool, an authorized administrator can issue the DEFINE  
STGPOOL command.  
ANR1558E  
ANR1559E  
ANR1560E  
The space management migration destination in management class management  
class name in policy set policy set name refers to copy storage pool: storage pool  
name. Copy storage pools are not a valid migration destination.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for set name, the  
server has found a space management migration destination that references a copy  
storage pool named pool name.  
System Action: Server operation continues. The policy set is not activated.  
User Response: To locate the management class that refers to the copy storage  
pool, issue the QUERY MGMTCLASS command. To change the destination to refer  
to a non-copy storage pool, issue the UPDATE MGMTCLASS command.  
The copy group destination for type copy group type in management class  
management class name in policy set policy set name refers to copy storage pool:  
storage pool name. Copy storage pools are not a valid copy group destination.  
Explanation: This message may be returned from the VALIDATE POLICYSET or  
ACTIVATE POLICYSET command. During policy set validation for set name, the  
server has found a copy group destination that references a copy storage pool named  
pool name.  
System Action: Server operation continues. The policy set is not activated.  
User Response: To locate the management class that refers to the copy storage  
pool, issue the QUERY MGMTCLASS command. To change the destination to refer  
to a non-copy storage pool, issue the UPDATE MGMTCLASS command.  
Command: Invalid policy domain name - domain name.  
Explanation: Server processing for the command command fails because the  
policy domain name domain name specified does not contain valid characters or  
contains too many characters.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a policy domain name that  
conforms to these name requirements. For information on the character and length  
specifications for valid policy domain names, refer to the Administrators Reference  
for your particular platform.  
Tivoli Storage Manager Messages  
243  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1561E  
Command: Missing policy domain name.  
Explanation: Server processing for the command command fails because the  
required policy domain parameter has not been specified.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid policy domain name.  
ANR1562E  
Command: Policy domain description exceeds length limit characters.  
Explanation: Server processing for the command command fails because the  
policy domain description specified is longer than the length limit number of  
characters allowed.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a shorter policy domain  
description.  
ANR1563E  
Command: Invalid retention period for BACKRETN parameter - retention value.  
Explanation: Server processing for the copy group command command fails  
because the value (retention value) specified for the BACKRETN parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid BACKRETN value. For  
valid BACKRETN values for the DEFINE COPYGROUP or UPDATE  
COPYGROUP commands, refer to the Administrators Reference for your particular  
platform.  
ANR1564E  
Command: Invalid retention period for ARCHRETN parameter - retention value.  
Explanation: Server processing for the copy group command command fails  
because the value (retention value) specified for the ARCHRETN parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid ARCHRETN value. For  
valid ARCHRETN values for the DEFINE COPYGROUP or UPDATE  
COPYGROUP commands, refer to the Administrators Reference for your particular  
platform.  
244  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1565E  
Command: Invalid policy set name - set name.  
Explanation: Server processing for the command command fails because the  
policy set name set name specified does not contain valid characters or contains too  
many characters.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a policy set name that  
conforms to valid name requirements. For information on the character and length  
specifications for valid policy set names, refer to the Administrators Reference for  
your particular platform.  
ANR1566E  
Command: Policy set description exceeds length limit characters.  
Explanation: Server processing for the command command fails because the  
policy set description specified is longer than the length limit number of characters  
allowed.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a shorter policy set description.  
ANR1567E  
Command: Invalid management class name - class name.  
Explanation: Server processing for the command command fails because the  
management class name class name specified does not contain valid characters or  
contains too many characters.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a management class name that  
conforms to valid name requirements. For information on the character and length  
specifications for valid management class names, refer to the Administrators  
Reference for your particular platform.  
ANR1568E  
Command: Management class description exceeds length limit characters.  
Explanation: Server processing for the command command fails because the  
management class description specified is longer than the length limit number of  
characters allowed.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
Tivoli Storage Manager Messages  
245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command and specify a shorter management class  
description. Refer to the Administrators Guide for your particular platform for more  
information.  
ANR1569E  
ANR1570E  
ANR1571E  
Command: Invalid copy group name - group name.  
Explanation: Server processing for the command command fails because the copy  
group name group name specified does not contain valid characters or contains too  
many characters.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a copy group name that  
conforms to valid name requirements. For information on the character and length  
specifications for valid copy group names, refer to the Administrators Reference for  
your particular platform.  
Command: Invalid copy frequency - frequency value.  
Explanation: Server processing for the copy group command command fails  
because the value (frequency value) specified for the FREQUENCY parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid FREQUENCY value.  
For valid FREQUENCY values for the DEFINE COPYGROUP or UPDATE  
COPYGROUP commands, refer to the Administrators Reference for your particular  
platform.  
Command: Invalid copy destination - pool name.  
Explanation: Server processing for the command command fails because the  
storage pool name pool name specified for the copy group destination does not  
contain valid characters or contains too many characters.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a storage pool name that  
conforms to valid name requirements. For information on the character and length  
specifications for valid storage pool names, refer to the Administrators Reference  
for your particular platform. For a list of names of defined storage pools, issue the  
QUERY STGPOOL command.  
246  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1572E  
Command: Missing copy destination.  
Explanation: Server processing for the copy group command command fails  
because the required copy group destination is not specified.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify the required copy group  
destination (DEST).  
ANR1573E  
Command: Invalid copy type - type value.  
Explanation: Server processing for the copy group command command fails  
because the value (type value) specified for the TYPE parameter is not valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid TYPE value. For valid  
TYPE values for the DEFINE COPYGROUP or UPDATE COPYGROUP  
commands, refer to the Administrators Reference for your particular platform.  
ANR1574E  
Command: Invalid version count for VEREXISTS parameter - version value.  
Explanation: Server processing for the copy group command command fails  
because the value (version value) specified for the VEREXISTS parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid VEREXISTS value. For  
valid VEREXISTS values for the DEFINE COPYGROUP or UPDATE  
COPYGROUP commands, refer to the Administrators Reference for your particular  
platform.  
ANR1575E  
Command: Invalid version count for VERDELETED parameter - version value.  
Explanation: Server processing for the copy group command command fails  
because the value (version value) specified for the VERDELETED parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
Tivoli Storage Manager Messages  
247  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command and specify a valid VERDELETED value.  
For valid VERDELETED values for the DEFINE COPYGROUP or UPDATE  
COPYGROUP commands, refer to the Administrators Reference for your particular  
platform.  
ANR1576E  
Command: Invalid retention period for RETEXTRA parameter - retention value.  
Explanation: Server processing for the copy group command command fails  
because the value (retention value) specified for the RETEXTRA parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid RETEXTRA value. For  
valid RETEXTRA values for the DEFINE COPYGROUP or UPDATE  
COPYGROUP commands, refer to the Administrators Reference for your particular  
platform.  
ANR1577E  
Command: Invalid retention period for RETONLY parameter - retention value.  
Explanation: Server processing for the copy group command command fails  
because the value (retention value) specified for the RETONLY parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid RETONLY value. For  
valid RETONLY values for the DEFINE COPYGROUP or UPDATE COPYGROUP  
commands, refer to the Administrators Reference for your particular platform.  
ANR1578E  
Command: Invalid version count for RETVER parameter - retention value.  
Explanation: Server processing for the copy group command command fails  
because the value (retention value) specified for the RETVER parameter is not  
valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid RETVER value. For  
valid RETVER values for the DEFINE COPYGROUP or UPDATE COPYGROUP  
commands, refer to the Administrators Reference for your particular platform.  
248  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1579E  
Command: Invalid copy mode - mode value.  
Explanation: Server processing for the copy group command command fails  
because the value (mode value) specified for the MODE parameter is not valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid MODE value. For valid  
MODE values for the DEFINE COPYGROUP or UPDATE COPYGROUP  
commands, refer to the Administrators Reference for your particular platform.  
ANR1580E  
Command: Invalid copy serialization mode - serialization value.  
Explanation: Server processing for the copy group command command fails  
because the value (serialization value) specified for the SERIALIZATION parameter  
is not valid.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify a valid SERIALIZATION  
value. For valid SERIALIZATION values for the DEFINE COPYGROUP or  
UPDATE COPYGROUP commands, refer to the Administrators Reference for your  
particular platform.  
ANR1581E  
Command: The option option is valid only for backup copy groups.  
Explanation: Server processing for the archive copy group command command  
fails because the option specified is only valid for backup copy group definitions.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying valid archive copy group  
options, or specify TYPE=BACKUP if the intent is to operate on a backup copy  
group. For valid archive copy group options, refer to the Administrators Reference  
and Administrators Guide for your particular platform.  
ANR1582E  
Command: The option option is valid only for archive copy groups.  
Explanation: Server processing for the backup copy group command command  
fails because the option specified is only valid for archive copy group definitions.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying valid backup copy group  
options, or specifying TYPE=ARCHIVE if the intent is to operate on an archive  
Tivoli Storage Manager Messages  
249  
Download from Www.Somanuals.com. All Manuals Search And Download.  
copy group. For valid backup copy group options, refer to the Administrators  
Reference and Administrators Guide for your particular platform.  
ANR1583E  
ANR1584E  
ANR1585E  
Command: Copy frequency for archive copy groups must be CMD - frequency  
value is not valid.  
Explanation: Server processing for the archive copy group command command  
fails because a value other than CMD has been specified for the FREQUENCY  
parameter. The only value that may be specified for the archive copy group  
FREQUENCY parameter is CMD.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying CMD for the FREQUENCY  
parameter, or omitting the FREQUENCY parameter because the default value for  
FREQUENCY is CMD for archive copy groups. For valid archive copy group  
options, refer to the Administrators Reference and Administrators Guide for your  
particular platform.  
Command: Copy mode for archive copy groups must be ABSOLUTE - mode  
value is not valid.  
Explanation: Server processing for the archive copy group command command  
fails because a value other than ABSOLUTE has been specified for the MODE  
parameter. The only value that may be specified for the archive copy group MODE  
parameter is ABSOLUTE.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying ABSOLUTE for the MODE  
parameter, or omitting the MODE parameter because the default value for MODE is  
ABSOLUTE for archive copy groups. For valid archive copy group options, refer to  
the Administrators Reference and Administrators Guide for your particular  
platform.  
Command: Policy set ACTIVE cannot be modified.  
Explanation: Server processing for the command command fails because the  
policy set name ACTIVE is specified. Objects in the ACTIVE policy set for a  
domain may only be changed through activation of another policy set.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a policy set other than ACTIVE.  
To copy the ACTIVE policy set for a policy domain to another name so that  
250  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
commands may be used to change its contents, issue the COPY POLICYSET  
command. Then to activate the changes, issue the ACTIVATE POLICYSET  
command.  
ANR1586E  
ANR1587E  
ANR1590E  
ANR1591E  
Command: Invalid migration destination - pool name.  
Explanation: Server processing for the command command fails because the  
storage pool name pool name specified for the migration destination is a copy pool.  
A copy pool is not a valid migration destination.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command using a storage pool name that is not a  
copy pool. For a list of names of defined storage pools, issue the QUERY  
STGPOOL command.  
Command: Invalid copy group destination - pool name.  
Explanation: Server processing for the command command fails because the  
storage pool name pool name specified for the copy group destination is a copy  
pool. A copy pool is not a valid copy group destination.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command using a storage pool name that is not a  
copy pool. For a list of names of defined storage pools, issue the QUERY  
STGPOOL command.  
Command: Policy domain domain name is not defined.  
Explanation: Server processing for the command command fails because the  
policy domain name domain name specified does not refer to a defined policy  
domain in the server database.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a policy domain name that is  
defined in the server database. For a list of the names of defined policy domains in  
the server database, issue the QUERY DOMAIN command.  
Command: Policy domain domain name is already defined.  
Explanation: Server processing for the command command fails because the  
policy domain name domain name specified refers to a policy domain that is already  
defined in the server database.  
Tivoli Storage Manager Messages  
251  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a policy domain name that is not  
defined in the server database. For a list of the names of defined policy domains in  
the server database, issue the QUERY DOMAIN command.  
ANR1592E  
Command: Policy domain domain name still contains at least one policy set.  
Explanation: Server processing for the delete command command fails because  
the policy domain name domain name specified refers to a policy domain that still  
contains at least one policy set.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: To delete the policy set from the policy domain, issue the  
DELETE POLICYSET command.  
ANR1593E  
Command: Policy domain domain name still contains at least one node.  
Explanation: Server processing for the delete command command fails because  
the policy domain name domain name specified refers to a policy domain that still  
contains at least one node. A policy domain cannot be deleted if one or more client  
nodes are still assigned to the domain.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: To remove remaining nodes from the policy domain, issue the  
REMOVE NODE command. After all nodes are removed, issue the delete command  
again.  
ANR1594E  
Command: Policy domain domain name has no active policy set.  
Explanation: Server processing for the update or register node command  
command fails because the policy domain name domain name specified refers to a  
policy domain that does not have an active policy set defined. Nodes cannot be  
assigned to policy domains that do not have an active policy set.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: To activate a policy set for the specified policy domain, issue the  
ACTIVATE POLICYSET command. After a policy set has been activated, client  
nodes may be assigned to the policy domain.  
252  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1595E  
Command: Policy set set name is not defined in policy domain domain name.  
Explanation: Server processing for the command command fails because the  
policy set name set name specified does not refer to a defined set in policy domain  
domain name in the server database.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a policy set name that is defined  
in the policy domain. For a list of the names of defined policy sets in the policy  
domain, issue the QUERY POLICYSET command.  
ANR1596E  
Command: Policy set set name is already defined in policy domain domain name.  
Explanation: Server processing for the command command fails because the  
policy set name set name specified refers to a policy set that is already defined in  
policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a policy set name that is not  
defined in the policy domain. For a list of the names of defined policy sets in the  
policy domain, issue the QUERY POLICYSET command.  
ANR1597E  
policy set command: Policy set set name in domain domain name still contains at  
least one management class.  
Explanation: The policy set command failed because the set still contains at least  
one management class definition.  
System Action: The command fails and server operation continues.  
User Response: Remove the remaining management classes from the policy set  
and reissue the command.  
ANR1598E  
Command: No default management class has been assigned for policy set set  
name in domain domain name.  
Explanation: Server processing for the command command fails because the  
policy set set name in policy domain domain name does not have a default  
management class assigned.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: To assign a default management class in the policy set, issue the  
ASSIGN DEFMGMTCLASS command.  
Tivoli Storage Manager Messages  
253  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1599E  
ANR1600E  
ANR1602E  
Command: Management class class name is not defined in policy domain domain  
name, set set name.  
Explanation: Server processing for the command command fails because the  
management class name class name specified does not refer to a defined  
management class in policy set set name belonging to policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a policy set name that is defined  
in the policy domain. For a list of the names of defined policy sets in the policy  
domain, issue the QUERY POLICYSET command.  
Command: Management class class name is already defined in policy domain  
domain name, set set name.  
Explanation: Server processing for the command command fails because the  
specified management class name class name refers to a management class that is  
already defined in policy set set name belonging to policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a management class name that is  
not defined in the policy set. For a list of the names of defined management classes  
in the policy domain and policy set, issue the QUERY MGMTCLASS command.  
Command: Backup copy group group name is not defined in policy domain  
domain name, set set name, management class class name.  
Explanation: Server processing for the command command fails because the  
backup copy group named group name specified for management class class name  
does not refer to a defined backup copy group in policy set set name belonging to  
policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a copy group name that is  
defined. For a list of the names of defined copy groups and management classes in  
the policy domain or policy set, issue the QUERY COPYGROUP command.  
254  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1603E  
Command: Backup copy group group name is already defined in policy domain  
domain name, set set name, management class class name.  
Explanation: Server processing for the command command fails because the  
specified backup copy group named group name refers to a copy group that is  
already defined for management class (class name) in policy set set name belonging  
to policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a copy group that is not defined  
in the policy set. For a list of the names of defined copy groups for management  
classes in the policy domain and policy set, issue the QUERY COPYGROUP  
command.  
ANR1604E  
Command: Archive copy group group name is not defined in policy domain  
domain name, set set name, management class class name.  
Explanation: Server processing for the command command fails because the  
archive copy group named group name specified for management class class name  
does not refer to a defined archive copy group in policy set set name belonging to  
policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a copy group name that is  
defined. For a list of the names of defined copy groups and management classes in  
the policy domain or policy set, issue the QUERY COPYGROUP command.  
ANR1605E  
Command: Archive copy group group name is already defined in policy domain  
domain name, set set name, management class class name.  
Explanation: Server processing for the command command fails because the  
specified archive copy group named group name refers to a copy group that is  
already defined for management class class name in policy set set name belonging  
to policy domain domain name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command specifying a copy group that is not defined  
in the policy set. For a list of the names of defined copy groups for management  
classes in the policy domain and policy set, issue the QUERY COPYGROUP  
command.  
Tivoli Storage Manager Messages  
255  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1606E  
Out of server LOG space in accessing policy tables.  
Explanation: The server ends a database update transaction for policy information  
because sufficient log space is not available on the server.  
System Action: The policy operation is ended and server operation continues.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log and can issue the  
EXTEND LOG command to extend the size of the log so that the new volumes are  
used.  
ANR1607E  
Out of server DB space in accessing policy tables.  
Explanation: The server ends a database update transaction for policy information  
because sufficient database space is not available on the server.  
System Action: The policy operation is ended and server operation continues.  
User Response: An authorized administrator can issue the DEFINE DBVOLUME  
command to add volumes for use by the database and can issue the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
ANR1608E  
Error fetching entry for domain domain name, set set name.  
Explanation: An internal server database error occurs while retrieving policy  
information for policy set set name in domain domain name.  
System Action: The policy operation is ended and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR1609E  
Policy error: unable to find management class ID for class class name in policy  
set set name belonging to domain domain name.  
Explanation: An internal server database error has been encountered while  
retrieving policy information for management class class name in policy set set  
name belonging to policy domain domain name.  
System Action: The policy operation is ended and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
256  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1610E  
Internal Server error: invalid copy type copy type integer encountered in policy  
set validation.  
Explanation: An internal server database error has been encountered while  
validating a policy set in response to the VALIDATE POLICYSET or ACTIVATE  
POLICYSET command.  
System Action: The policy operation is ended and server operation continues.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Use the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR1611E  
Command: Invalid management class name - management class name.  
Explanation: Server processing for the command command fails because the  
specified management class name may not be used as a management class name.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: Reissue the command and specify another management class  
name.  
ANR1612E  
Command: Management class management class name in policy set set name,  
domain domain name specifies MIGREQUIRESBKUP=YES, but contains no  
backup copy group.  
Explanation: During policy set validation or activation for policy set set name in  
policy domain domain name, the server has found that the management class named  
class name specifies the MIGREQUIRESBKUP=YES parameter but does not  
contain a backup copy group. Policy set validation or activation fails in this case  
because it would not be possible to ensure that space-managed client files are  
backed up prior to being migrated to the server.  
System Action: Database changes for the command are rolled back and server  
operation continues. The command is not successful in changing the server database.  
User Response: To define a backup copy group within the management class,  
issue the DEFINE COPYGROUP command. To change the MIGREQUIRESBKUP  
parameter, issue the UPDATE MGMTCLASS command.  
ANR1650E  
Server server name is not defined.  
Explanation: The server name was not created using the DEFINE SERVER  
command. This entry was created using the REGISTER NODE  
NODETYPE=SERVER command and is not a valid reference.  
Tivoli Storage Manager Messages  
257  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The current action for the device class referring to this server fails.  
User Response: The device class referring to this node as the SERVERNAME  
should be updated to refer to a valid server entry. Specifically, it should refer to an  
entry created using the DEFINE SERVER command.  
ANR1651E  
Server information for server name is not available.  
Explanation: The information for server name was not available.  
System Action: The current server action fails.  
User Response: Please review any other messages prior to this message to  
determine the cause of the failure.  
ANR1652E  
Server information for server name could not be read from a device  
configuration file.  
Explanation: An attempt to a server definition for server name from any device  
configuration files failed.  
System Action: The current action for the device class referring to this server fails.  
User Response: Please verify the existence of a device configuration file and the  
DEFINE SERVER stanza within that file.  
ANR1653E  
Resource lock acquisition for server server name failed.  
Explanation: The acquisition of the resource lock for server server name failed.  
System Action: The current action for the device class referring to this server fails.  
User Response: Retry the action referring to the device class that refers to this  
server name. If the lock failure persists, please contact your service representative.  
ANR1654E  
Server server name will not be written to a device configuration file.  
Explanation: An error occurred accessing the information for server name while  
trying to write this information to a device configuration file.  
System Action: This DEFINE SERVER entry is not processing.  
User Response: Verify that the necessary DEFINE SERVER entries were written  
to a device configuration file. If this error persists, please contact your service  
representative.  
258  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1655E  
Failure processing password for Server server name when writing a device  
configuration file.  
Explanation: An error occurred processing the password for server name while  
trying to write this information to a device configuration file.  
System Action: This DEFINE SERVER entry is written to the device  
configuration file without the password.  
User Response: The password needs to be specified after PASSWORD= for this  
DEFINE SERVER entry in the device configuration file.  
ANR1656E  
Failure writing server definitions to a device configuration file.  
Explanation: An error occurred writing the server information to a device  
configuration file.  
System Action: The BACKUP DEVCONFIG action fails.  
User Response: Check that the device configuration file exists and that the file  
system the file resides on is not out of space.  
ANR1657E  
Command: Invalid server or group name - server or group name.  
Explanation: The command shown specifies an invalid server or server group  
name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid name.  
ANR1658E  
Command: Failure determining NODENAME for server server name.  
Explanation: The command shown was unable to determine a node name either  
from the NODENAME= parameter on this command or from the server name  
previously set using the SET SERVERNAME command.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid node name parameter or else  
update the server name using the SET SERVERNAME command so that a valid  
name is available.  
ANR1659E  
Command: Server or server group server or group name is already defined.  
Explanation: A DEFINE SERVER or DEFINE SERVERGROUP command has  
been entered that specifies a server or server group name that already exists. The  
Tivoli Storage Manager Messages  
259  
Download from Www.Somanuals.com. All Manuals Search And Download.  
name specified must be a unique name. It must not duplicate a node name used by  
a registered node, a server name used by a defined server, or a server group name  
used by a defined server group.  
System Action: The server does not process the command.  
User Response: To define the server or server group, reissue the command and  
specify a different name.  
ANR1660I  
ANR1661I  
ANR1662I  
Server server name defined successfully.  
Explanation: The requested server has been defined to the system in response to a  
DEFINE SERVER command.  
System Action: None.  
User Response: None.  
Server server name deleted.  
Explanation: In response to a DELETE SERVER command, the requested server  
has been removed from the system.  
System Action: None.  
User Response: None.  
Server server name updated.  
Explanation: One or more attributes of a server have been updated by an  
UPDATE SERVER command.  
System Action: None.  
User Response: None.  
ANR1663E  
ANR1664W  
command: Server server name not defined  
Explanation: The server server name is not defined to the system.  
System Action: The command fails.  
User Response: None.  
Command: Server server name is currently in use.  
Explanation: The command shown specifies a server that is currently in use. The  
server is referenced by one or more of the following: a device class of  
260  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEVTYPE=SERVER that specifies this server for the ’SERVERNAME=’  
parameter, it is defined as the event server, or a connection with this server is  
currently open and in use.  
System Action: The server does not process the command.  
User Response: Reissue the command at a later time. In order to delete the server  
specified, it must not be currently connected to the server, it may not be referenced  
in a device class, and it can not be defined to be the event server.  
ANR1665E  
ANR1666E  
command: Failure updating password for server server name.  
Explanation: An error occurred updating the password for server name.  
System Action: The command fails.  
User Response: Re-try the command specifying a different password.  
command: FILEAGGR not allowed with NODETYPE=SERVER.  
Explanation: The FILEAGGR= parameter may not be specified with the  
NODETYPE=SERVER parameter also being specified.  
System Action: The command fails.  
User Response: Reissue the command command without the FILEAGGR=  
parameter if this is a NODETYPE=SERVER.  
ANR1667E  
command: Action not permitted against node node name.  
Explanation: The command is not permitted against the entry for node node  
name. This node entry has a NODETYPE of SERVER.  
System Action: The command fails.  
User Response: None.  
ANR1668E  
command: Not allowed for server server name.  
Explanation: The DELETE SERVER command is not permitted for server server  
name. The specified server is either the event server or else it is a node entry rather  
than a server definition.  
System Action: The command fails.  
User Response: If the specified server is the event server, and you want to delete  
it, issue the DELETE EVENTSERVER command and then reissue the DELETE  
SERVER command. To remove a node entry, issue the REMOVE NODE command  
for the specified name.  
Tivoli Storage Manager Messages  
261  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1669I  
ANR1670E  
Server event server name is defined as the event server.  
Explanation: The specified server is defined.  
System Action: None.  
User Response: None.  
Server event server name is already defined as the event server. You must issue  
the DELETE EVENTSERVER command before defining a new event server.  
Explanation: An event server is already defined.  
System Action: The command fails.  
User Response: Delete the existing Event Server and try the command again.  
ANR1671I  
The event server definition has been deleted.  
Explanation: The event server definition has been deleted.  
System Action: None.  
User Response: If an event server definition is desired, use the DEFINE  
EVENTSERVER command.  
ANR1672I  
No event server is currently defined.  
Explanation: A query was issued to get the name of the event server; however, no  
event server is currently defined.  
System Action: None.  
User Response: If an event server definition is desired, use the DEFINE  
EVENTSERVER command.  
ANR1673I  
Server group group name defined successfully.  
Explanation: The requested server group is defined to the system in response to a  
DEFINE SERVERGROUP command.  
System Action: None.  
User Response: None.  
ANR1674I  
Member member name defined successfully in server group group name.  
Explanation: The requested member is defined in the server group in response to  
a DEFINE GRPMEMBER command.  
262  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR1675I  
ANR1676I  
ANR1677I  
ANR1678I  
ANR1679E  
Server group server group name deleted.  
Explanation: The requested server is removed from the system in response to a  
DELETE SERVERGROUP command.  
System Action: None.  
User Response: None.  
Member member name deleted from server group server group name.  
Explanation: The requested member is removed from the server group in response  
to a DELETE GRPMEMBER command,  
System Action: None.  
User Response: None.  
Server group server group name updated.  
Explanation: One or more attributes of a server group is updated by an UPDATE  
SERVERGROUP command.  
System Action: None.  
User Response: None.  
Server group original server group name renamed new server group name.  
Explanation: A server group is renamed by a RENAME SERVERGROUP  
command. The original name is not valid.  
System Action: None.  
User Response: None.  
command: Server group server group name not defined  
Explanation: The server server group name is not defined to the system.  
System Action: The command fails.  
User Response: Retry the command specifying an existing group.  
Tivoli Storage Manager Messages  
263  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1680E  
ANR1681E  
ANR1682E  
ANR1683E  
ANR1684E  
command: Member member name not defined in server group server group name.  
Explanation: The member member name is not defined in server group server  
group name.  
System Action: The command fails.  
User Response: Retry the command specifying an existing member of the group.  
command: Member member name is already in server group server group name.  
Explanation: The member member name is defined in server group server group  
name.  
System Action: The command fails.  
User Response: Retry the command and specify a new member name.  
A group cannot be a member of itself.  
Explanation: The member and group name are the same. A group may not be a  
member of itself.  
System Action: The command fails.  
User Response: Retry the command and specify another member name.  
command: Member member name not defined.  
Explanation: The member member name is not defined to the system. Server  
group members must be a defined server or server group.  
System Action: The command fails.  
User Response: Retry the command specifying existing server or group.  
route:command: Routed commands cannot be routed.  
Explanation: The command part of a routed command may not contain route  
information itself. The allowable syntax for routed commands is “:”. The command  
may not contain route information. Only one level of routing is allowed.  
System Action: Routed commands where the command portion contains additional  
routing information are not processed.  
User Response: Reissue the command without specifying route information in the  
command portion of this routed command.  
264  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1685I  
Server group server group copied to server group new server group.  
Explanation: This message is displayed in response to the COPY  
SERVERGROUP command. The server group named server group is copied to the  
server group named new server group.  
System Action: None.  
User Response: None.  
ANR1686I  
Member member name moved from server group group name to server group  
new group name.  
Explanation: The requested member member name is moved from server group  
group name to the server group new server group in response to a MOVE  
GRPMEMBER command.  
System Action: None.  
User Response: None.  
ANR1687I  
ANR1688I  
ANR1689E  
Output for command \’command\’ issued against server server name follows:  
Explanation: The output for the command issued against the indicated server  
follows this message.  
System Action: None.  
User Response: None.  
Output for command \’command\’ issued against server server name completed.  
Explanation: This message marks the end of the output for the command specified  
that was issued against the indicated server.  
System Action: None.  
User Response: None.  
Output for command \’command\’ issued against server server name terminated.  
Explanation: An error condition occurred causing the output for the command  
issued against the specified server to be terminated.  
System Action: None.  
User Response: Re-try the command against the requested server once the error  
condition has been resolved. If the cause of the error can not be determined, please  
contact your local service representative.  
Tivoli Storage Manager Messages  
265  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1690E  
Error sending command \’command\’ to server server name.  
Explanation: An error was encountered sending the specified command to the  
server indicated.  
System Action: None.  
User Response: Re-try the command against the requested server once the error  
condition has been resolved. If the cause of the error can not be determined, please  
contact your local service representative.  
ANR1691E  
Error receiving response from server server name for command \’command\’.  
Explanation: An error was encountered receiving the response from the server  
indicated for the command that was issued against it.  
System Action: None.  
User Response: Re-try the command against the requested server once the error  
condition has been resolved. If the cause of the error can not be determined, please  
contact your local service representative.  
ANR1692E  
Response for command \’command\’ from server server name contains invalid  
data.  
Explanation: The output returned from the specified server for the command that  
was issued, contains invalid output. The command response can not be processed.  
System Action: Output processing for this command response terminates.  
User Response: Please contact your local service representative.  
ANR1693E  
Unable to issue command \’command\’ against server server name - failure  
starting thread.  
Explanation: A thread could not be started to issue the specified command against  
the server indicated.  
System Action: This command is not issued against the server specified. The  
process will attempt to issue the command against any other servers that were  
specified for the command routing information.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Re-try routing this command to the indicated  
server after the cause of the error has been determined and resolved. If the error  
cannot be isolated and resolved, contact your service representative.  
266  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1694I  
Server server name processed command \’command\’ and completed successfully.  
Explanation: The server indicated processed the command successfully.  
System Action: None.  
User Response: None.  
ANR1695W  
Server server name processed command \’command\’ but completed with  
warnings.  
Explanation: The server indicated processed the command but encountered  
warnings. However, the warnings did not prevent the execution of the command.  
System Action: None.  
User Response: None.  
ANR1696E  
Server server name attempted to process command \’command\’ but encountered  
errors.  
Explanation: The server indicated processed the command but encountered errors.  
These errors prevented the successful completion of the command.  
System Action: None.  
User Response: Examine any error messages issued on either the server sending  
the command or else the server executing the command to determine the cause of  
the failure. Reissue the command once these errors are corrected.  
ANR1697I  
Command \’command\’ processed by total number for servers server(s): number  
of successful servers successful, number of servers with warnings with warnings,  
and number of servers with errors with errors.  
Explanation: The indicated command was processed by the number of servers  
specified. For the total number of servers, the number indicated were successful, the  
number indicated encountered a warning condition but processed anyway, and  
finally, the number indicated encountered errors and could not process.  
System Action: None.  
User Response: None.  
ANR1698I  
Command \’command\’ was not issued against any other servers.  
Explanation: The indicated command was not issued against any other server.  
Either the routing information did not resolve to any valid servers or else failures  
occurred issuing the command against the required servers. indicated number of  
server.  
Tivoli Storage Manager Messages  
267  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: Check to see that valid route information was provided for the  
command or else check the activity log for error messages that indicate why the  
command was not issued to the other server.  
ANR1699I  
Resolved route information to number of servers server(s) - issuing command  
command against server(s).  
Explanation: The route information was resolved to the number of servers  
indicated. The specified command will be issued against those servers.  
System Action: None.  
User Response: None.  
ANR1700E  
Unable to resolve \’route information\’ to any server(s).  
Explanation: The route information provided for this command did not resolve to  
any server names or group names. Because of this, the command will not be issued.  
System Action: None.  
User Response: Examine the route information provided. Reissue the command  
providing correct route information.  
ANR1701E  
ANR1702W  
Command: No matching servers defined.  
Explanation: No matching servers are found for the specified command.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify different servers.  
Skipping \’server name\’ - unable to resolve to a valid server name.  
Explanation: The server name specified is being skipped because it could not be  
resolved to a valid server name.  
System Action: None.  
User Response: Reissue the command providing the correct server name.  
ANR1703E  
Failure resolving server names.  
Explanation: An error occurred while resolving the server names. Specifically, the  
resolution of the server names has terminated because of a significant failure.  
System Action: None.  
268  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check the activity log and server console for other messages  
about the cause of the failure. Once the cause has been resolved, reissue the  
command.  
ANR1704E  
Failure obtaining credentials for administrator admin name.  
Explanation: An error occurred obtaining the credentials for the administrator  
referenced.  
System Action: Command processing fails.  
User Response: Check the activity log and server console for other messages  
about the cause of the failure. Once the cause has been resolved, reissue the  
command.  
ANR1705W  
Ping for server \’server name\’ was not able to establish a connection.  
Explanation: The ping command was unable to establish a connection to the  
server specified. This could indicate a problem on the server issuing the ping, a  
problem with the communication connection between the two servers, or else it is a  
problem with the other server.  
System Action: None.  
User Response: Check the activity log and server console for messages that  
indicate a failure or problem on the server issuing this command. Next, check the  
communication connection between the two servers. Also, check the server  
definition and password on both the server issuing the command and the server  
specified. And finally, verify that the server specified is running.  
ANR1706I  
Ping for server \’server name\’ was able to establish a connection.  
Explanation: The ping command was able to establish a connection to the server  
specified.  
System Action: None.  
User Response: Check the activity log and server console for messages that  
indicate a failure or problem on the server issuing this command. Next, check the  
communication connection between the two srevers. And finally, verify the  
operation of the server specified.  
ANR1707I  
Server information not complete, crossdefine not allowed.  
Explanation: The SERVERHLADDRESS, SERVERLLADDRESS or  
SERVERPASSWORD has not been set for this server. These are required for the  
CROSSDEFINE option on the define server command.  
System Action: The command fails.  
Tivoli Storage Manager Messages  
269  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the QUERY STATUS command to find what values need to  
be set. An authorized administratormust issue the SET SERVERHLADDRESS, SET  
and SERVERLLADDRESS or SET SERVERPASSWORD command to set the  
missing values.  
ANR1708I  
Define server for Server name failed because the crossdefine failed.  
Explanation: The define server command failed because the crossdefine parameter  
was included, and the crossdefine was not successful.  
System Action: The command fails.  
User Response: Check this server, and the server being defined for other messages  
indicating the reason for the failure.  
ANR1709E  
Command.: Failure determining current usage for server or group name Server  
name.  
Explanation: The specified command failed to determine the current use of the  
server name or server group specified.  
System Action: The command fails.  
User Response: Retry the command. If it continues to fail and the cause of the  
failure can not be determined, please contact your local service representative.  
ANR1710E  
Command.: Name Name not valid for this command.  
Explanation: The name specified for this command is not valid for this operation.  
The first case is that a server name was specified for a command requiring a server  
group name. The other case is where a server group name was specified for a  
command requiring a server name.  
System Action: The command fails.  
User Response: Retry the command specifying the proper name.  
ANR1711E  
Error accessing the server or server group name Name.  
Explanation: A server operation attempted to access the server name or server  
group name specified. An error occurred while trying to access the information for  
this server name or server group name.  
System Action: The server opteration fails.  
User Response: Review the activity log to try to determine the cause of the  
failure. If a cause can not be determines, please contact your local service  
representative.  
270  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1712W  
ANR1713I  
Command routing not allowed from server console.  
Explanation: Command routing is not allowed from the server console.  
System Action: The command is not executed.  
User Response: Reissue the command from an Administrative client.  
Command \’command\’ issued against server server name.  
Explanation: The specified command has been sent to the indicated server. The  
command is to terminate the specified server, no confirmation will be recieved.  
System Action: None.  
User Response: None.  
ANR1714W  
The password for administrator administartor name has expired. The password  
for this administrator must be updated on the configuration manager server  
server name.  
Explanation: The password for the named administrator has expired, but the  
administrator is a managed object on this server. The password must be updated on  
the named configuration manager server.  
System Action: The administrator is allow access to the server.  
User Response: Change the administrator’s password on the named configuration  
manager server.  
ANR1715E  
Event server cannot be deleted - it is currently active.  
Explanation: The event server cannot be deleted since it is currently active for  
event logging.  
System Action: The server does not delete the event server entry.  
User Response: In order to delete the event server, it must not be currently active  
for event logging. To stop event logging to the event server issue END  
EVENTLOGGING EVENTSERVER. Then reissue the DELETE EVENTSERVER  
command.  
ANR1716I  
Server cannot be crossdefined to itself, crossdefine not allowed.  
Explanation: An attempt was made to crossdefine the server to itself.  
System Action: The command fails.  
User Response: None.  
Tivoli Storage Manager Messages  
271  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1800E  
Missing or invalid EVENTLOG command parameter.  
Explanation: The event logging command issued contains an invalid parameter, or  
is missing a required parameter.  
System Action: The command is ignored.  
User Response: Reissue the command with the proper parameters.  
ANR1801E  
Eventlog command: Invalid event or event class - Event or event class name.  
Explanation: An event logging command has been entered which specifies an  
unknown event or event class.  
System Action: The command is ignored for the invalid event or event class. Any  
valid events or classes specified are processed.  
User Response: Reissue the command with the correct event or event class.  
ANR1808E  
ANR1809E  
ANR1810E  
Unable to open event log file file spec for appending.  
Explanation: The server cannot write to a file which has been specified for event  
logging.  
System Action: No logging will be done to the file receiver.  
User Response: Check the file for proper access permissions, or specify a different  
file for logging.  
Insufficient memory to activate event logging.  
Explanation: A BEGIN EVENTLOGGING command has been entered, but the  
server has insufficient memory available to activate logging.  
System Action: The command is ignored.  
User Response: If logging is required, make more memory available to the server  
then restart the server.  
Eventlog command: Invalid receiver - receiverName.  
Explanation: An event logging command has been entered which specifies an  
unknown event log receiver (maybe unknown just to this platform).  
System Action: The command is ignored for the invalid receiver. Any valid  
receivers specified are processed.  
User Response: Reissue the command with the correct receiver.  
272  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1822I  
Event logging ended for the receiverName receiver.  
Explanation: In response to an END EVENTLOGGING command or because an  
error occurred, event log records are no longer being output to the specified  
receiver.  
System Action: None.  
User Response: None.  
ANR1823I  
Event logging ended for all receivers.  
Explanation: In response to an END EVENTLOGGING command, event log  
records are no longer being output to any receiver.  
System Action: None.  
User Response: None.  
ANR1824E  
Event logging is inactive for the specified receiver.  
Explanation: An END EVENTLOGGING command has been entered, but logging  
is not active for the specified receiver.  
System Action: The command is ignored.  
User Response: If logging is desired, use the ENABLE EVENT and BEGIN  
EVENTLOGGING commands to activate event logging.  
ANR1825I  
Event logging active for the receiverName receiver.  
Explanation: In response to a BEGIN EVENTLOGGING command, event log  
records are now being output to the specified receiver.  
System Action: None.  
User Response: None.  
ANR1826I  
Event logging active for all receivers.  
Explanation: In response to a BEGIN EVENTLOGGING command, event log  
records are now being output to all receivers.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
273  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1827E  
ANR1828E  
ANR1829E  
Eventlog command: No valid receiver specified.  
Explanation: An event logging command has been entered, and no valid receivers  
were specified.  
System Action: The command is ignored.  
User Response: Reissue the command with the correct receiver.  
Eventlog command: No valid event specified.  
Explanation: An event logging command has been entered and no valid events or  
event classes were specified.  
System Action: The command is ignored.  
User Response: Reissue the command with the correct events or event classes.  
Eventlog command: Server events may not be disabled for the activity log  
receiver.  
Explanation: A DISABLE EVENT command has been entered for the activity log  
receiver.  
System Action: The command is ignored for the activity log receiver. Any valid  
receivers specified are processed.  
User Response: Reissue the command with the correct receiver.  
ANR1830E  
receiverName receiver options not defined in the server options file.  
Explanation: A BEGIN EVENTLOGGING command has been entered for a  
receiver, but the required receiver options were not specified in the server options  
file.  
System Action: Logging is not started for the specified receiver.  
User Response: Enter the receiver options in the server options file and restart the  
server.  
ANR1831I  
Event logging of client events ended for ACTLOG receiver.  
Explanation: An END EVENTLOGGING command has been entered for the  
activity log receiver.  
System Action: The server no longer records client events in the activity log.  
Server events continue to be recorded in the activity log.  
User Response: None.  
274  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR1842E  
An error occurred on the receiverName receiver.  
Explanation: An error occurred on the specified receiver.  
System Action: The server no longer sends events to the receiver.  
User Response: Issue a BEGIN EVENTLOGGING command for the receiver to  
attempt to start logging events to the receiver again.  
ANR1843I  
ANR1844I  
Event log receiver initialization in progress.  
Explanation: Initialization is starting for the eventlog receivers.  
System Action: None.  
User Response: None.  
Eventlog command command processed.  
Explanation: The specified command was processed.  
System Action: None.  
User Response: If any previous messages indicate that parts of the command  
failed, reissue the command for those parts only.  
ANR1850E  
Circular event logging detected. The event server has previously handled event  
Event number from Source trail. To prevent looping, events which have already  
been logged by the event server are not sent again. Please correct the situation  
causing circular logging to avoid wasting system resources.  
Explanation: The server is attempting to log an event which has previously been  
handled by the event server that is currently defined.  
System Action: The event is not sent to the event server. Other events will still be  
sent, and this message will be issued periodically if this situation is detected again.  
User Response: Determine what is wrong with the server to server event logging  
setup, and fix the problem.  
ANR1851E  
The source trail for server to server event logging has exceeded the maximum  
length of Maximum sourcetrail length bytes.  
Explanation: While attempting to log an event to the event server, the server has  
found that the source trail length is too long.  
System Action: The server continues to try to send the event to the event server,  
but the source trail may be truncated and appear something like:  
Tivoli Storage Manager Messages  
275  
Download from Www.Somanuals.com. All Manuals Search And Download.  
name1>...>namex>namey  
where,  
name1  
...  
is the originator of the event.  
is where intervening server name(s) have been left off the source  
trail.  
User Response: Most likely you are using very long server names and/or have  
excessive hops from server to server. Either use shorter server names or change  
your configuration to reduce the number of hops.  
ANR1852E  
ANR1853E  
ANR1854E  
ANR2000E  
Unable to send header to TEC at TEC server rc return code  
Explanation: A network error has occurred in attempting to send the event header  
to the Tivoli Enterprise Console.  
System Action: None.  
User Response: Verify network connections and contact your service  
representative if this error persists.  
Unable to send data to TEC at TEC server rc return code  
Explanation: A network error has occurred in attempting to send the event data to  
the Tivoli Enterprise Console.  
System Action: None.  
User Response: Verify network connections and contact your service  
representative if this error persists.  
Unable to flush data to TEC at TEC server rc return code  
Explanation: A network error has occurred in attempting to flush data to the  
Tivoli Enterprise Console .  
System Action: None.  
User Response: Verify network connections and contact your service  
representative if this error persists.  
Unknown command - command.  
Explanation: The specified command is not a valid server command.  
System Action: The server ignores the command.  
User Response: Reissue the correct command.  
276  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2001E  
Insufficient server memory to initiate command.  
Explanation: A command has been entered, but the server cannot obtain enough  
internal memory to process the command.  
System Action: The server ignores the command.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2002E  
ANR2003E  
ANR2004E  
Missing closing quote character.  
Explanation: A server command that contains a quoted parameter has been  
entered, but a matching closing quote is missing.  
System Action: The server ignores the command.  
User Response: Reissue the command with properly matched quotes.  
Illegal use of keyword parameter character (=) - parameter.  
Explanation: A server command contains the parameter shown followed by an  
equal sign (=), but the parameter is not a keyword parameter.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
Missing value for keyword parameter - parameter.  
Explanation: A server command containing a keyword parameter has been  
entered, but the value for the parameter is missing.  
System Action: The server ignores the command.  
User Response: Reissue the command and supply a value for the keyword  
parameter.  
ANR2005E  
Keyword parameter character (=) may not be surrounded by blanks.  
Explanation: A server command contains a keyword parameter followed by an  
equal sign (=), but the equal sign is preceded or followed by a blank, or both.  
System Action: The server ignores the command.  
User Response: Reissue the command without blanks next to the equal sign.  
Tivoli Storage Manager Messages  
277  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2006E  
Activity log process was not started, the default output stream cannot be  
opened.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log cannot access that output stream.  
System Action: The server does not update the activity log.  
User Response: Contact your service representative.  
ANR2007E  
Activity log process was not started, due to an internal error.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log cannot start due to a server internal error.  
System Action: The server does not update the activity log.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR2008E  
Activity log process has stopped - database transaction could not be started.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log cannot continue due to a server transaction failure. This  
may be a memory shortage error.  
System Action: The server stops updating the activity log.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2009E  
Activity log process has stopped - database error.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log cannot continue due to a server database error.  
System Action: The server stops updating the activity log.  
User Response: Contact your service representative.  
ANR2010W  
Server is out of LOG space in adding entries to the Activity Log. Console  
messages will not be logged until LOG space is available.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log cannot update the activity log due to a lack of recovery  
log space.  
278  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not update the activity log.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log, and can issue the  
EXTEND LOG command to extend the size of the log so that the new volumes are  
used.  
ANR2011W  
Server is out of DB space in adding entries to the Activity Log. Console  
messages will not be logged until DB space is available.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log cannot update the activity log due to a lack of database  
space.  
System Action: The server does not update the activity log.  
User Response: An authorized administrator can issue the DEFINE DBVOLUME  
command to add volumes for use by the database, and can issue the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
ANR2012W  
Activity log process has encountered unexpected table data output in the  
default output stream.  
Explanation: The process that monitors the default (console) output stream and  
maintains the activity log has detected invalid data in the console stream.  
System Action: The server stops updating the activity log.  
User Response: Contact your service representative.  
ANR2013E  
The activity log process has encountered unexpected output data in the console  
output stream. The process will be restarted.  
Explanation: The process that monitors console output and maintains the activity  
log has detected invalid data (unknown data type) in the console stream.  
System Action: The server restarts the activity log recording process. While the  
process is restarting, the server may not be able to record some console messages in  
the activity log.  
User Response: The server may be low on available memory. Allocate additional  
storage to the server. For details, issue HELP MEMORY to display the information  
online or see “Appendix A. Allocating Additional Server Memory”.  
ANR2014E  
Activity log pruning process could not be started, due to an internal error.  
Explanation: The process that removes expired records from the server activity  
log cannot begin execution due to a server internal error.  
Tivoli Storage Manager Messages  
279  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not prune the activity log.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR2015E  
Activity log failure - database transaction could not be started.  
Explanation: The process that removes expired records from the server activity  
log has failed due to a database transaction failure, which may be a memory  
shortage error.  
System Action: The server ends activity log pruning.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2016E  
Activity log failure - database error.  
Explanation: The process that removes expired records from the server activity  
log has failed due to a server database error.  
System Action: The server ends activity log pruning.  
User Response: Contact your service representative.  
ANR2017I  
Administrator Administrator Name issued command: Command  
Explanation: This message records the fact that the named administrator issued  
the command specified. The messages is issued and looged to provide an audit trail  
for administrative commands.  
System Action: Server operation continues  
User Response: None.  
ANR2019I  
Command: No nodes updated.  
Explanation: An UPDATE NODE command has been entered, but no objects  
were updated.  
System Action: None.  
User Response: None.  
280  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2020E  
ANR2021E  
ANR2022E  
ANR2023E  
ANR2024E  
ANR2025E  
Command: Invalid parameter - parameter.  
Explanation: The specified server command has been entered with an invalid  
parameter.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
Command: Missing subcommand keyword.  
Explanation: The specified server command has been entered without a valid  
subcommand (second parameter).  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
Command: One or more parameters are missing.  
Explanation: The specified server command has been entered without all required  
parameters.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
Command: Extraneous parameter - parameter.  
Explanation: The specified server command contains more positional parameters  
than is allowed.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
Command: Too many parameters specified.  
Explanation: The specified server command contains more positional parameters  
than is allowed.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
Command: Command failed - server thread resource not available.  
Explanation: A server command, which has a requirement to start a server thread,  
has been entered but cannot be executed because no server thread is available.  
Tivoli Storage Manager Messages  
281  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command is not executed.  
User Response: Reissue the command. If the command fails with the same error,  
wait for server activity to decrease and try again.  
ANR2026E  
Command: Command failed - sufficient server memory is not available.  
Explanation: A server command has been entered but cannot be processed  
because sufficient memory is not available to the server.  
System Action: The server does not process the command.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2027E  
Command: Command failed - sufficient server recovery log space is not  
available.  
Explanation: A server command has been entered but cannot be processed  
because sufficient recovery log space is not available.  
System Action: The server does not process the command.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log, and can issue the  
EXTEND LOG command to extend the size of the log so that the new volumes are  
used.  
ANR2028E  
Command: Command failed - sufficient server database space is not available.  
Explanation: A server command has been entered but cannot be processed  
because sufficient database space is not available.  
System Action: The server does not process the command.  
User Response: An authorized administrator can issue the DEFINE DBVOLUME  
command to add volumes for use by the database, and can issue the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
ANR2029E  
Command: Transaction failed; command not executed.  
Explanation: A command that is part of the current transaction has failed;  
therefore, any additional commands fail.  
System Action: The server does not process the command.  
User Response: Stop the administrative session, restart it, and try the command  
again. If this problem persists, contact your service representative.  
282  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2030E  
ANR2031E  
ANR2032E  
Commit not accepted; transaction failed.  
Explanation: A command that is part of the current transaction has failed;  
therefore, a COMMIT command cannot be processed.  
System Action: The server does not process the COMMIT command.  
User Response: Stop the administrative session, restart it, and try the command  
again. If this problem persists, contact your service representative.  
Command: At least one attribute must be specified for update.  
Explanation: The specified UPDATE command has been entered, but no attributes  
have been specified for updating.  
System Action: The server ignores the command.  
User Response: Reissue the UPDATE command with one or more attributes to be  
updated.  
Command: Command failed - internal server error detected.  
Explanation: An internal error has occurred during an attempt to process a server  
command. This message always accompanies another error message and provides  
more detail about that error.  
System Action: The server does not process the command.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR2033E  
Command: Command failed - lock conflict.  
Explanation: A server command that requires the server to lock a system resource  
has been entered. The command cannot be executed because the resource is already  
in use by another command or process.  
System Action: The server does not process the command.  
User Response: Try the command again at a later time.  
ANR2034E  
Command: No match found using this criteria.  
Explanation: The specified command has been entered, but no objects that match  
the criteria can be found.  
System Action: None.  
Tivoli Storage Manager Messages  
283  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2035E  
Command: Administrator administrator name is not authorized to issue this  
command.  
Explanation: The specified administrator has entered the indicated command, but  
this administrator does not have the proper authority necessary to run the command.  
Note: This message can be issued as a result of the server option  
REQSYSAUTHOUTFILE YES being in effect.  
System Action: The server does not process the command.  
User Response: Examine previous messages for any additional information. Issue  
the command from a properly authorized administrator ID, or contact the system  
administrator to have additional authority granted to the current administrator ID.  
ANR2036E  
Command: Process could not be started - sufficient memory is not available.  
Explanation: A background process cannot be started for the indicated command  
because sufficient memory is not available to the server.  
System Action: A new process is not started to execute this command.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2037E  
Command: Process could not be started - lock conflict.  
Explanation: A background process cannot be started for the indicated command  
because a required system resource is already locked by another command or  
process.  
System Action: A new process is not started to execute this command. If other  
processes have been started for this command, these processes may execute  
successfully.  
User Response: If necessary, try the command again at a later time.  
ANR2038E  
Command: Process could not be started - server thread resource not available.  
Explanation: A background process cannot be started for the indicated command  
because no server thread is available.  
System Action: A new process is not started to execute this command. If other  
processes have been started for this command, these processes may execute  
successfully.  
284  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If necessary, reissue the command. If the command fails with the  
same error, wait for server activity to decrease and try again.  
ANR2039E  
Command: Process could not be started - internal server error detected.  
Explanation: A background process cannot be started for the indicated command  
because an internal error has occurred.  
System Action: A new process is not started to execute this command. If other  
processes have been started for this command, these processes may execute  
successfully.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
ANR2040W  
This command attempts to restore all files in storage pool storage pool which  
have previously been found to be damaged or which reside on a volume with  
access mode destroyed; existing references to files in storage pool storage pool  
will be deleted from the database after the files have been restored.  
Explanation: Issuing the RESTORE STGPOOL command will result in deletion  
of existing files in the indicated primary storage pool after these files have been  
restored from a copy storage pool. If a volume with access mode destroyed becomes  
empty because all files on the volume have been restored to another location, the  
destroyed volume will be deleted from the database.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to restore the storage pool, 'N' otherwise.  
ANR2041W  
This command attempts to restore all files in storage pool storage pool which  
reside on one of the volumes specified in the command; existing references to  
files on these volumes will be deleted from the database after the files have  
been restored.  
Explanation: Issuing the RESTORE VOLUME command causes the access mode  
of the specified volumes to be updated to destroyed. Existing files will be deleted  
from the specified volumes after these files have been restored from a copy storage  
pool. If a volume with access mode destroyed becomes empty because all files on  
the volume have been restored to another location, the destroyed volume will be  
deleted from the database.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to restore the volumes, 'N' otherwise.  
Tivoli Storage Manager Messages  
285  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2042E  
Command: Copied parameter not valid for copy storage pool volume.  
Explanation: The QUERY CONTENT server command has been entered with an  
invalid parameter. COPIED is not a valid parameter when the volume specified  
belongs to a copy storage pool.  
System Action: The server ignores the command.  
User Response: Reissue the command without the COPIED parameter.  
ANR2043E  
Command: WAIT parameter not allowed from server console.  
Explanation: The WAIT parameter is not allowed for commands issued from the  
server console.  
System Action: The command is not executed.  
User Response: Either reissue the command without the WAIT parameter or else  
reissue the command from an administrator using an Administrative Client.  
ANR2044E  
ANR2045E  
Command: Invalid option’s value - Option’s value.  
Explanation: The set option command has been entered with an invalid value.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid value.  
Command: An error (error code) occurred during a write operation.  
Explanation: The server detects an error while attempting a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation has failed.  
ANR2046I  
optionset name: Optionset optionset name defined.  
Explanation: The requested option set has been added to the system in response to  
a DEFINE OPTIONSET command.  
System Action: None.  
User Response: None.  
ANR2047E  
Command: Optionset optionset name is already defined.  
Explanation: A DEFINE OPTIONSET command has been entered that specifies  
an optionset name already defined to the server.  
286  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not process the command.  
User Response: To define the optionset, reissue the command and specify a  
different optionset name.  
ANR2048I  
ANR2049E  
ANR2050I  
ANR2051E  
Command: Optionset optionset name deleted.  
Explanation: The requested option set has been deleted from the system in  
response to a DELETE OPTIONSET command.  
System Action: None.  
User Response: None.  
Command: Optionset optionset name is not defined.  
Explanation: The command shown specifies an optionset that is not defined in the  
server.  
System Action: The server does not process the command.  
User Response: None.  
Command: Option option name defined in optionset option set name.  
Explanation: The requested option has been added to the specified optionset in  
response to a DEFINE OPTIONSET command.  
System Action: None.  
User Response: None.  
Command: Option option name, sequence number sequence number is already  
defined in optionset option set name.  
Explanation: The requested option already exists in the optionset specified by the  
DEFINE CLIENTOPT command.  
System Action: The server does not process the command.  
User Response: None.  
ANR2052E  
Command: Option option name, sequence number sequence number is not defined  
in optionset option set name.  
Explanation: The requested option is not defined in the optionset specified by the  
DELETE CLIENTOPT command.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
287  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2053I  
Command: Option option name, sequence number sequence number, has been  
deleted from optionset option set name.  
Explanation: The requested option has been deleted from the specified optionset  
in response to a DELETE CLIENTOPT command.  
System Action: None.  
User Response: None.  
ANR2054I  
Command: Optionset optionset name updated.  
Explanation: The requested option set has been updated in the system in response  
to an UPDATE OPTIONSET command.  
System Action: None.  
User Response: None.  
ANR2055I  
Command: Optionset source optionset name copied to optionset target optionset  
name.  
Explanation: This message is displayed in response to the COPY OPTIONSET  
command. The optionset named source optionset name has been copied to the  
optionset named target optionset name.  
System Action: Server operation continues.  
User Response: None. The requested option set has been added to the system in  
response to a COPY OPTIONSET command.  
ANR2056E  
ANR2057E  
Command: Invalid option name - option name. Retry using the full optionname.  
Explanation: The command shown specifies an invalid option name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid option name.  
Command: Invalid option value - option value.  
Explanation: The command shown specifies an invalid option value.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid option value.  
288  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2058W  
Command: Options file Filespec not found - user needs to update the file  
manually.  
Explanation: The server options file cannot be opened or found.  
System Action: The command is processed but the option is not updated in the  
options file.  
User Response: Use a text editor to update the server options file if the user wants  
to use this value when the server restarts later. If the user does not update the file,  
the current value in the options file will be used when the server restarts.  
ANR2059W  
Command: Error occurs when writing to Filespec - user needs to update the file  
manually.  
Explanation: An error occurs when trying to write the new value to the server  
options file.  
System Action: The command is processed but the option is not updated in the  
options file.  
User Response: Use a text editor to update the server options file if the user wants  
to use this value when the server restarts later. If the user does not update the file,  
the current value in the options file will be used when the server restarts.  
ANR2060I  
Node node name registered in policy domain domain name.  
Explanation: The requested backup-archive node has been added to the system in  
response to a REGISTER NODE command and has been assigned to the policy  
domain indicated.  
System Action: None.  
User Response: None.  
ANR2061I  
Node node name removed from policy domain domain name.  
Explanation: In response to a REMOVE NODE command, the requested  
backup-archive node has been removed from the system.  
System Action: None.  
User Response: None.  
ANR2062I  
Node node name renamed to new node name.  
Explanation: In response to a RENAME NODE command, the requested  
backup-archive node has been renamed to the new name shown.  
System Action: None.  
Tivoli Storage Manager Messages  
289  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2063I  
ANR2064I  
ANR2065I  
ANR2066I  
ANR2067I  
Node node name updated.  
Explanation: One or more attributes of a backup-archive node have been updated  
by an UPDATE NODE command.  
System Action: None.  
User Response: None.  
Node node name locked.  
Explanation: In response to a LOCK NODE command, the indicated  
backup-archive node has been locked.  
System Action: None.  
User Response: None.  
Node node name is already locked.  
Explanation: The indicated backup-archive node referenced in the LOCK NODE  
command is already locked.  
System Action: None.  
User Response: None.  
Node node name unlocked.  
Explanation: In response to an UNLOCK NODE command, the indicated  
backup-archive node is unlocked.  
System Action: None.  
User Response: None.  
Node node name is already unlocked.  
Explanation: The indicated backup-archive node referenced in the UNLOCK  
NODE command is not locked.  
System Action: None.  
User Response: None.  
290  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2068I  
ANR2069I  
ANR2070I  
ANR2071I  
ANR2072I  
ANR2073I  
Administrator administrator ID registered.  
Explanation: In response to a REGISTER ADMIN command, the requested  
administrator ID has been added to the system.  
System Action: None.  
User Response: None.  
Administrator administrator ID removed.  
Explanation: In response to a REMOVE ADMIN command, the requested  
administrator ID has been removed from the system.  
System Action: None.  
User Response: None.  
Administrator administrator ID renamed to new administrator ID.  
Explanation: In response to a RENAME ADMIN command, the requested  
administrator ID has been changed to the new name shown.  
System Action: None.  
User Response: None.  
Administrator administrator ID updated.  
Explanation: One or more attributes of an administrative user have been updated  
by an UPDATE ADMIN command.  
System Action: None.  
User Response: None.  
Administrator administrator ID locked.  
Explanation: In response to a LOCK ADMIN command, the indicated  
administrator ID has been locked.  
System Action: None.  
User Response: None.  
Administrator administrator ID is already locked.  
Explanation: The indicated administrator ID referenced in the LOCK ADMIN  
command is already locked.  
Tivoli Storage Manager Messages  
291  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR2074I  
ANR2075I  
ANR2076I  
ANR2077I  
ANR2078I  
Administrator administrator ID unlocked.  
Explanation: In response to an UNLOCK ADMIN command, the indicated  
administrator ID is unlocked.  
System Action: None.  
User Response: None.  
Administrator administrator ID is already unlocked.  
Explanation: The indicated administrator ID referenced in the UNLOCK ADMIN  
command is not locked.  
System Action: None.  
User Response: None.  
System privilege granted to administrator administrator ID.  
Explanation: In response to a GRANT AUTHORITY command, system privilege  
class has been granted to the indicated administrator.  
System Action: None.  
User Response: None.  
Unrestricted policy privilege granted to administrator administrator ID.  
Explanation: In response to a GRANT AUTHORITY command, unrestricted  
policy privilege has been granted to the indicated administrator.  
System Action: None.  
User Response: None.  
Restricted policy privilege granted to administrator administrator ID - policy  
domain domain name.  
Explanation: In response to a GRANT AUTHORITY command, restricted policy  
privilege for the specified policy domain has been granted to the indicated  
administrator.  
System Action: None.  
User Response: None.  
292  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2079I  
Unrestricted storage privilege granted to administrator administrator ID.  
Explanation: In response to a GRANT AUTHORITY command, unrestricted  
storage privilege has been granted to the indicated administrator.  
System Action: None.  
User Response: None.  
ANR2080I  
Restricted storage privilege granted to administrator administrator ID - storage  
pool storage pool name.  
Explanation: In response to a GRANT AUTHORITY command, restricted storage  
privilege for the specified storage pool has been granted to the indicated  
administrator.  
System Action: None.  
User Response: None.  
ANR2081I  
ANR2082I  
ANR2083I  
Analyst privilege granted to administrator administrator ID.  
Explanation: In response to a GRANT AUTHORITY command, analyst privilege  
class has been granted to the indicated administrator.  
System Action: None.  
User Response: None.  
Operator privilege granted to administrator administrator ID.  
Explanation: In response to a GRANT AUTHORITY command, operator privilege  
class has been granted to the indicated administrator.  
System Action: None.  
User Response: None.  
System privilege revoked for administrator administrator ID.  
Explanation: In response to a REVOKE AUTHORITY command, system  
privilege class has been revoked from the indicated administrator.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
293  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2084I  
Policy privilege revoked for administrator administrator ID.  
Explanation: In response to a REVOKE AUTHORITY command, policy privilege  
class for all policy domains has been revoked from the indicated administrator.  
System Action: None.  
User Response: None.  
ANR2085I  
Restricted policy privilege revoked for administrator administrator ID - policy  
domain domain name.  
Explanation: In response to a REVOKE AUTHORITY command, restricted policy  
privilege for the specified policy domain has been revoked from the indicated  
administrator.  
System Action: None.  
User Response: None.  
ANR2086I  
Storage privilege revoked for administrator administrator ID.  
Explanation: In response to a REVOKE AUTHORITY command, storage  
privilege class for all storage pools has been revoked from the indicated  
administrator.  
System Action: None.  
User Response: None.  
ANR2087I  
Restricted storage privilege revoked for administrator administrator ID - storage  
pool storage pool name.  
Explanation: In response to a REVOKE AUTHORITY command, restricted  
storage privilege for the storage pool indicated has been revoked from the indicated  
administrator.  
System Action: None.  
User Response: None.  
ANR2088I  
Analyst privilege revoked for administrator administrator ID.  
Explanation: In response to a REVOKE AUTHORITY command, analyst  
privilege class has been revoked from the indicated administrator.  
System Action: None.  
User Response: None.  
294  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2089I  
Operator privilege revoked for administrator administrator ID.  
Explanation: In response to a REVOKE AUTHORITY command, operator  
privilege class has been revoked from the indicated administrator.  
System Action: None.  
User Response: None.  
ANR2090I  
Activity log retention period set to number of days days.  
Explanation: The number of days that activity records are kept in the server  
activity log has been set to the value indicated with the SET ACTLOGRETENTION  
command.  
System Action: None.  
User Response: None.  
ANR2091I  
ANR2092I  
ANR2093I  
Accounting parameter set to value.  
Explanation: Accounting record generation has been turned on or off as indicated  
with the SET ACCOUNTING command.  
System Action: None.  
User Response: None.  
Password expiration period set to number of days days.  
Explanation: The number of days that a password can be used before it must be  
changed has been set to the value indicated with the SET PASSEXP command.  
System Action: None.  
User Response: None.  
Registration parameter set to registration method.  
Explanation: Backup-archive node registration has been set to the method  
indicated with the SET REGISTRATION command.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
295  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2094I  
Server name set to server name.  
Explanation: The name that the server displays and communicates to  
backup-archive nodes has been set to the value indicated with the SET  
SERVERNAME command.  
System Action: None.  
User Response: None.  
ANR2095I  
Authentication parameter set to value.  
Explanation: The requirement for a node or administrator to enter a password  
when establishing a session with the server has been turned on or off as indicated  
with the SET AUTHENTICATION command.  
System Action: None.  
User Response: None.  
ANR2096I  
ANR2097I  
ANR2098E  
Server now enabled for backup/archive client access.  
Explanation: The server has been made available for use by backup-archive  
clients with the ENABLE command.  
System Action: None.  
User Response: None.  
Server now disabled for backup/archive client access.  
Explanation: The server has been made unavailable for use by backup-archive  
clients with the DISABLE command.  
System Action: None.  
User Response: None.  
Command: Invalid URL specification - url.  
Explanation: The specified URL is too long.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter a shorter URL value  
296  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2099I  
Administrative userid admininstrator name defined for OWNER access to node  
node name.  
Explanation: An administrator with the specified name was created having  
OWNER access to the client node. This administrator is created for accessing the  
client node from an interactive interface.  
System Action: None.  
User Response: None.  
ANR2100I  
Activity log process has started.  
Explanation: The automatic server process that removes expired server activity  
log records has begun processing.  
System Action: None.  
User Response: None.  
ANR2101I  
Activity log process stopped, activity log retention set to 0.  
Explanation: A SET ACTLOGRETENTION command has set the retention period  
to zero days. As a result, activity logging stops.  
System Action: The activity log process stops recording console output in the  
server activity log.  
User Response: None.  
ANR2102I  
Activity log pruning started: removing entries prior to date time.  
Explanation: Server activity log records older than the date and time indicated are  
being removed from the activity log.  
System Action: None.  
User Response: None.  
ANR2103I  
Activity log pruning completed: number of records records removed.  
Explanation: All expired (older than the log archive retention value) server  
activity log records have been removed; the number of records deleted is shown.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
297  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2104I  
Activity log process restarted - recovered from an insufficient space condition  
in the Log or Database.  
Explanation: The process that records data in the server activity log has failed  
because of insufficient space in the server recovery log or database; space is now  
available and the process is again recording data.  
System Action: Activity logging resumes.  
User Response: None.  
ANR2105W  
Command: Node was registered in excess of license terms - node registration  
will fail after 120% of the licensed quantity of nodes have been registered.  
Explanation: The server has detected the addition of a node in excess of the terms  
under which the server is licensed. The REGISTER NODE command will fail after  
120% of the licensed number of nodes have been registered.  
System Action: Server operation continues.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance. You may remove nodes to reduce the  
number of registered nodes or purchase additional client node connections. If  
additional nodes have been purchased, issue the AUDIT LICENSES command to  
resynchronize the server configuration with license terms.  
ANR2106I  
Server HALT command: Quiescing database update activity.  
Explanation: The server is quiescing transactions that update the database so that  
the database is in a consistent state when the server is halted. This action occurs  
when HALT QUIESCE is specified to halt the server with the database in a  
consistent state.  
System Action: When database update transaction activity has been stopped, the  
server program ends.  
User Response: None.  
ANR2107I  
Server HALT command: Database update activity is now quiesced.  
Explanation: The server has stopped all database update transaction activity. This  
action occurs when HALT QUIESCE is specified to halt the server with the  
database in a consistent state.  
System Action: The server program ends.  
User Response: None.  
298  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2108I  
Server HALT command: Reattempting to quiesce database update activity.  
Explanation: The server is quiescing transactions that update the database so that  
the database is in a consistent state when the server is halted. The previous attempt  
at quiescing database activity failed because of the current transaction load on the  
server. The quiesce operation is being reattempted. This action occurs when HALT  
QUIESCE is specified to halt the server with the database in a consistent state.  
System Action: When database update transaction activity has been stopped, the  
server program ends.  
User Response: None.  
ANR2109I  
Server HALT command: Database update transaction activity could not be  
successfully quiesced.  
Explanation: After repeated attempts, server database update transaction activity  
could not be quiesced. The server is not halted with the HALT QUIESCE command.  
Attempts to quiesce database update transaction activity can fail if heavy transaction  
load is on the server when a HALT QUIESCE command is entered.  
System Action: Server operation continues.  
User Response: You may disable the server, cancel all client sessions accessing  
the server, cancel all processes, and reenter the HALT QUIESCE command to stop  
server processing. The HALT command may also be used to stop server processing  
without quiescing database transaction update activity. Server recovery logic will be  
used when the server is restarted to reconcile database transaction activity.  
ANR2110I  
Command started as process process ID.  
Explanation: A background process has been started to service the command  
command. The background process is defined as process process ID.  
System Action: The server processes the indicated command.  
User Response: To query the progress of the background process, use the QUERY  
PROCESS command. To cancel the background process, use the CANCEL  
PROCESS command. Use the process ID number to specify this process.  
ANR2111W  
Command: No data to process.  
Explanation: The indicated command does not have any data to process. This can  
occur if the command specifies an empty volume or pool. The command ends  
without starting a background process.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
299  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2112E  
Command: Volume volume name is not in a primary storage pool.  
Explanation: The command indicated specifies the name of a volume that does  
not belong to a primary storage pool. The command syntax requires that a volume  
in a primary storage pool be specified.  
System Action: The server does not process the command.  
User Response: Reissue the command with a volume in a primary pool.  
ANR2113E  
Command: Volume volume name does not belong to the same storage pool  
(storage pool name) as previously listed volumes.  
Explanation: The indicated command accepts a list of one or more volumes which  
belong to the same storage pool. The named volume does not belong to the same  
storage pool as the previously listed volumes.  
System Action: The server does not process the command.  
User Response: Issue the command with a list of volumes that belong to the same  
storage pool.  
ANR2114I  
Command: Access mode for volume volume name updated to destroyed.  
Explanation: A RESTORE VOLUME command has updated the access mode of  
the indicated volume to destroyed.  
System Action: Restore processing continues.  
User Response: None.  
ANR2115E  
Command: Access mode for volume volume name cannot be changed to  
destroyed- volume is still online.  
Explanation: A RESTORE VOLUME command cannot change the access mode  
of the indicated volume to destroyed because the volume is still online.  
System Action: The server does not process the command.  
User Response: Issue the VARY OFFLINE command, and reissue the RESTORE  
VOLUME command.  
ANR2116E  
Command: Access mode for volume volume name cannot be changed to  
destroyed- volume does not belong to a primary storage pool.  
Explanation: The access mode for the indicated volume cannot be changed to  
destroyed because the volume does not belong to a primary storage pool.  
System Action: The access mode for this volume is not changed.  
300  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2117E  
Command: Access mode for volume volume name cannot be changed to offsite″  
- volume either does not belong to a copy storage pool or from a device class of  
DEVTYPE=SERVER.  
Explanation: The access mode for the indicated volume cannot be changed to  
offsite because the volume either does not belong to a copy storage pool or is of a  
device class with a DEVTYPE of SERVER.  
System Action: The access mode for this volume is not changed.  
User Response: None.  
ANR2118E  
Storage pool storage pool name specified on the MOVE DATA command is not  
a valid poolname and or pooltype for volume volume name.  
Explanation: If the volume belongs to a primary storage pool, then the storage  
pool specified must also be a primary storage pool. If the volume belongs to a copy  
storage pool, then the specified storage pool must be the same storage pool as that  
of the volume.  
System Action: The MOVE DATA process fails.  
User Response: Provide a valid primary storage pool name if the volume belongs  
to a primary storage pool. If the volume belongs to a copy storage pool, remove the  
storage pool name from the command.  
ANR2119I  
ANR2120E  
The Option option has been changed in the options file.  
Explanation: The option is updated in the server options file.  
System Action: Server continues.  
User Response: None.  
Command: Invalid platform name - platform name.  
Explanation: The command shown specifies an invalid platform name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid platform name.  
Tivoli Storage Manager Messages  
301  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2121W  
ATTENTION: More than megabytes changed MB of the database has changed  
and the last database backup was more than hours name hours ago. Use the  
BACKUP DB command to provide for database recovery.  
Explanation: The server issues this warning when a significant amount of  
database change activity has occurred and the server database has not been backed  
up.  
System Action: Server operation continues.  
User Response: To provide for server database recovery should a hardware or  
software problem affect your database, use the BACKUP DB command to back up  
the database.  
ANR2122E  
ANR2123E  
ANR2124E  
command name: The DOMAINS parameter cannot be specified when the  
NODES parameter is specified.  
Explanation: Both the NODES and DOMAINS parameters were specified. The  
NODES parameter may be specified, or the DOMAINS parameter may be specfied,  
but both should not be specified at the same time.  
System Action: The command fails.  
User Response: Reenter the command specifying either the NODES parameter or  
the DOMAINS parameter, but not both.  
command name: The NODES parameter cannot be specified when the  
DOMAINS parameter is specified.  
Explanation: Both the NODES and DOMAINS parameters were specified. The  
NODES parameter may be specified, or the DOMAINS parameter may be specfied,  
but both should not be specified at the same time.  
System Action: The command fails.  
User Response: Reenter the command specifying either the NODES parameter or  
the DOMAINS parameter, but not both.  
command name: Invalid Client authority specified: authority.  
Explanation: An invalid client authority was specified in a GRANT AUTHORITY  
or REVOKE AUTHORITY command when the CLASS=NODE parameter was  
specified.  
System Action: The command fails.  
User Response: Reenter the command specifying a valid client authority.  
302  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2125I  
ANR2126I  
ANR2127I  
ANR2128I  
ANR2129I  
command name: Administrator administrator name was granted OWNER  
authority for client client name.  
Explanation: The named administrator was granted OWNER authority over the  
named client node as the result of a GRANT AUTHORITY command.  
System Action: Processing continues.  
User Response: None.  
command name: Administrator administrator name was granted ACCESS  
authority for client client name.  
Explanation: The named administrator was granted ACCESS authority over the  
named client node as the result of a GRANT AUTHORITY command.  
System Action: Processing continues.  
User Response: None.  
command name: Owner authority for node client node was revoked for  
administrator administrator.  
Explanation: OWNER authority over the named client node was revoked from the  
named administrator as a result of a REVOKE AUTHORITY command.  
System Action: Processing continues.  
User Response: None.  
command name: Access authority for node client node was revoked for  
administrator administrator.  
Explanation: ACCESS authority over the named client node was revoked from the  
named administrator as a result of a REVOKE AUTHORITY command.  
System Action: Processing continues.  
User Response: None.  
Administrative userid admininstrator name defined ONLY for authority over  
node node name has been removed.  
Explanation: The specified administrator has been removed because the client  
node was removed and the administrator onyly had OWNER access to the specified  
node.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
303  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2130S  
Early Product Version has Expired. Server is HALTing.  
Explanation: This server is pre-release version of the server. The pre-release  
version’s expiration date has been reached.  
System Action: The server halts.  
User Response: Install the product version of the server.  
ANR2131I  
Server password set.  
Explanation: The password that the server uses to allow other servers to  
communicate with it has been set, changed or removed with the SET  
SERVERPASSWORD command.  
System Action: None.  
User Response: None.  
ANR2132I  
ANR2133I  
ANR2134I  
Server hladdress set to hladdress.  
Explanation: The high level address that other servers use to communicate with  
this server has been set to the value indicated with the SET SERVERHLADDRESS  
command.  
System Action: None.  
User Response: None.  
Server lladdress set to lladdress.  
Explanation: The low level address that other servers use to communicate with  
this server has been set to the value indicated with the SET SERVERLLADDRESS  
command.  
System Action: None.  
User Response: None.  
Server url set to url.  
Explanation: The url that other servers use to communicate with this server has  
been set to the value indicated with the SET SERVERURL command.  
System Action: None.  
User Response: None.  
304  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2135I  
Crossdefine set to state.  
Explanation: The ability for another server to automatically define itself to this  
server has been turned on or off as indicated with the SET CROSSDEFINE  
command.  
System Action: None.  
User Response: None.  
ANR2136I  
Administrator administrator name already has POLICY access for domain policy  
domain name.  
Explanation: The named administrator already has POLICY authority over the  
named policy domain. An attempt to grant client authority over this domain is  
ignored.  
System Action: The policy domain is skipped.  
User Response: None.  
ANR2137I  
Administrator administrator name already has POLICY access for domain policy  
domain name to which node node name belongs.  
Explanation: The named administrator already has POLICY authority over the  
named policy domain. An attempt to grant client authority for a client in this  
domain is ignored.  
System Action: The client is skipped.  
User Response: None.  
ANR2138I  
Minimum password length set to length.  
Explanation: The minimum length of a password a node or administrator may  
send to the server is indicated with the SET MINPWLENGTH command.  
System Action: None.  
User Response: None.  
ANR2139E  
Command: The value supplied for the minimum password length is not valid -  
length.  
Explanation: A SET MINPWLENGTH command has been entered that specifies a  
value for the length is not valid. Valid values are from 0 to 64, inclusive.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid value.  
Tivoli Storage Manager Messages  
305  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2140E  
ANR2141E  
ANR2142E  
Command: Invalid activity log retention period - retention value.  
Explanation: A SET ACTLOGRETENTION command has been entered that  
specifies an invalid log retention period.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid retention period.  
Command: Invalid password expiration period - days value.  
Explanation: A SET PASSEXP command has been entered that specifies an  
invalid days value.  
System Action: The server does not process the command.  
User Response: Reissue the command with a password expiration period.  
Command: Invalid server name - server name.  
Explanation: A SET SERVERNAME command has been entered that specifies an  
invalid server name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid server name.  
ANR2143E  
ANR2144E  
ANR2145E  
Command: Invalid node name - node name.  
Explanation: The command shown specifies an invalid node name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid node name.  
Command: Invalid password - password.  
Explanation: The command shown specifies an invalid node password.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid password.  
Command: Contact information exceeds maximum characters characters.  
Explanation: A REGISTER NODE or REGISTER ADMIN command has been  
entered that specifies a contact information value that is too long. The maximum  
valid length is shown in the command.  
System Action: The server does not process the command.  
306  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command with less contact information.  
ANR2146E  
Command: Node node name is not registered.  
Explanation: The command shown specifies a node that is not registered with the  
server.  
System Action: The server does not process the command.  
User Response: None.  
ANR2147E  
Command: Node node name is already registered.  
Explanation: A REGISTER NODE command has been entered that specifies a  
node name already registered with the server.  
System Action: The server does not process the command.  
User Response: To register the node, reissue the command and specify a different  
node name.  
ANR2148E  
Command: Administrator administrator ID is not registered.  
Explanation: The command shown specifies an administrator ID that is not  
registered with the server.  
System Action: The server does not process the command.  
User Response: None.  
ANR2149E  
Command: Administrator administrator ID is already registered.  
Explanation: A REGISTER ADMIN command has been entered that specifies an  
administrator ID already registered with the server.  
System Action: The server does not process the command.  
User Response: To register the administrator, reissue the command and specify a  
different administrator ID.  
ANR2150E  
Command: Node node name is currently accessing the server.  
Explanation: The command shown specifies a node that has an active session with  
the server.  
System Action: The server does not process the command.  
User Response: Reissue the command at a later time, or if necessary, cancel the  
current session and reissue the command.  
Tivoli Storage Manager Messages  
307  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2151E  
Command: Administrator administrator ID is currently accessing the server.  
Explanation: An UPDATE ADMIN or REMOVE ADMIN command has been  
entered that specifies an administrator ID that is having an active session with the  
server.  
System Action: The server does not process the command.  
User Response: Reissue the command at a later time, or if necessary, cancel the  
current session and reissue the command.  
ANR2152E  
Command: Inventory references still exist for node node name.  
Explanation: A REMOVE NODE command has been entered for a node for  
which the server is still storing backup or archive data, or both.  
System Action: The server does not process the command.  
User Response: To remove the node, delete all of its file spaces from the server  
and reissue the command.  
ANR2153E  
Command: Invalid file space name - filespace name.  
Explanation: The specified server command has been entered with a file space  
name that is longer than allowed.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid file space name.  
ANR2154E  
ANR2155E  
Command: Invalid administrator name - administrator ID.  
Explanation: The command shown specifies an invalid administrator ID.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid administrator ID.  
Command: Invalid privilege class - privilege class.  
Explanation: A command specifies an invalid administrative privilege class.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid privilege class.  
308  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2156E  
ANR2157E  
ANR2158E  
Command: Administrator administrator ID has already been granted system  
privilege.  
Explanation: A GRANT AUTHORITY command has been issued to grant system  
authority to an administrator ID that already has system authority.  
System Action: The server does not process the command.  
User Response: None.  
Command: Other privileges cannot be granted with system privilege.  
Explanation: A GRANT AUTHORITY command has been issued to grant system  
authority to an administrator ID, and at the same time to grant other privileges.  
System Action: The server does not process the command.  
User Response: Reissue the GRANT AUTHORITY command specifying only  
system privilege class.  
Command: Policy domains cannot be specified for unrestricted policy  
administrator administrator ID.  
Explanation: A REVOKE AUTHORITY command has been issued to revoke an  
administrator’s policy authority over a specific policy domain, but the administrator  
has unrestricted policy authority.  
System Action: The server does not process the command.  
User Response: None.  
ANR2159E  
Command: Storage pools cannot be specified for unrestricted storage  
administrator administrator ID.  
Explanation: A REVOKE AUTHORITY command has been issued to revoke an  
administrator’s storage authority over a specific storage pool, but the administrator  
has unrestricted storage authority.  
System Action: The server does not process the command.  
User Response: None.  
ANR2160E  
Command: No new privileges granted to administrator administrator ID.  
Explanation: A GRANT AUTHORITY command has been issued to grant  
authority to an administrator ID, but the administrator already has all privileges  
specified.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
309  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2161E  
Command: Only system privilege can be revoked for administrator administrator  
ID.  
Explanation: A REVOKE AUTHORITY command has been issued to revoke one  
or more of an administrator’s privileges, but the administrator has system authority.  
System Action: The server does not process the command.  
User Response: None.  
ANR2162E  
Command: No privileges revoked for administrator administrator ID.  
Explanation: A REVOKE AUTHORITY command has been issued to revoke  
authority from an administrator ID, but the administrator does not have any of the  
privileges specified.  
System Action: The server does not process the command.  
User Response: None.  
ANR2163E  
Command: Command is invalid for administrator ID.  
Explanation: The command specified cannot be issued for the server console. For  
instance, the server console administrator ID cannot be removed.  
System Action: The server does not process the command.  
User Response: None.  
ANR2164E  
Command: Command rejected - administrator ID is the only system  
administrator.  
Explanation: A REMOVE ADMIN or REVOKE AUTHORITY command has  
been issued to remove or revoke the authority of the last administrator who had  
system authority.  
System Action: The server does not process the command.  
User Response: To remove or revoke this ID, grant system authority to another  
administrator ID before reissuing the command.  
ANR2165E  
Command: Invalid begin date - date.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid begin date as a search criteria.  
System Action: The server does not process the command.  
310  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command with a valid begin date.  
ANR2166E  
ANR2167E  
ANR2168E  
ANR2169E  
ANR2170E  
Command: Invalid begin time - time.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid begin time as a search criteria.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid begin time.  
Command: Invalid end date - date.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid end date as a search criteria.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid end date.  
Command: Invalid end time - time.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid end time as a search criteria.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid end time.  
Command: Invalid message number - message number.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid message number as a search criteria.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid message number.  
Command: Invalid message search string argument - search string.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid search string as a search criteria.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid search string.  
Tivoli Storage Manager Messages  
311  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2171E  
Command: Invalid time range - Begin: date time End: date time.  
Explanation: A QUERY ACTLOG command has been entered that specifies an  
invalid beginning and ending date/time range. This error can occur when the  
beginning date/time is not before the ending date/time.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid date/time range.  
ANR2172E  
Command: No matching administrators.  
Explanation: The command shown specified an administrator ID that does not  
match any administrator registered with the server.  
System Action: The command is not executed.  
User Response: If desired, reissue the command with a different administrator ID.  
ANR2173E  
Command: Location information exceeds maximum characters characters.  
Explanation: A DEFINE or UPDATE VOLUME command has been entered that  
specifies a location information value that is too long. The maximum valid length is  
shown in the command.  
System Action: The server does not process the command.  
User Response: Reissue the command with less location information.  
ANR2174E  
Administrator administrator ID is not registered. Schedule schedule name is not  
processed and is marked as failed.  
Explanation: The command shown specifies an administrator ID that is not  
registered with the server. The schedule and related command are not processed.  
System Action: The server does not process the command.  
User Response: Update the command schedule with a valid administrator ID  
which has the proper authority to execute the scheduled command.  
ANR2175I  
Invalid password limit set to password attempts limit attempts.  
Explanation: The maximum number of consecutive invalid passwords a node or  
administrator may send to the server is indicated with the SET INVALIDPWLIMIT  
command.  
System Action: None.  
User Response: None.  
312  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2176E  
Command: The value supplied for the invalid password attempts limit is not  
valid - password attempts limit.  
Explanation: A SET INVALIDPWLIMIT command has been entered that specifies  
a value for the consecutive invalid password attempts limit that is not valid. Valid  
values are from 0 to 9999, inclusive.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid value.  
ANR2177I  
node/admin name has count invalid sign-on attempts. The limit is limit.  
Explanation: The server detected an invalid password for the specified node  
during sign-on processing. The node currently has sent count consecutive invalid  
passwords. The maximum allowed is limit. The server will lock the node when limit  
is reached.  
System Action: The node or administrator session will be refused.  
User Response: Before the client node is permitted to access the server, a properly  
authorized administrator must unlock the node or administrator with the UNLOCK  
NODE or UNLOCK ADMIN command.  
ANR2178E  
node/admin name has been locked. Invalid sign-on attempt limit (limit) reached.  
Explanation: The specified node has been locked by the server. The limit for  
consecutive invalid passwords has been reached.  
System Action: The node or administrator session will be refused.  
User Response: Before the client node is permitted to access the server, a properly  
authorized administrator must unlock the node or administrator with the UNLOCK  
NODE or UNLOCK ADMIN command.  
ANR2179E  
Administrator administrator should have been locked, but was not.  
Explanation: The indicated administrator reached the limit for consecutive invalid  
passwords and should have been locked. If it were locked, there would be no means  
to execute commands requiring system authority.  
System Action: The administrator session will be refused.  
User Response: Sign-on again using the correct password.  
Tivoli Storage Manager Messages  
313  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2180W  
Unable to update last access date for administrator administrator ID -  
insufficient recovery log space.  
Explanation: While establishing an administrative session for the indicated ID, the  
server is unable to update the administrator’s date of last access due to insufficient  
recovery log space.  
System Action: The server establishes the administrative session, but the last  
access date is not updated.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log, and can issue the  
EXTEND LOG command to extend the size of the log so that the new volumes are  
used.  
ANR2181W  
Unable to update last access date for administrator administrator ID -  
insufficient database space.  
Explanation: While establishing an administrative session for the indicated ID, the  
server cannot update the administrator’s date of last access due to insufficient  
database space.  
System Action: The server establishes the administrative session, but the last  
access date is not updated.  
User Response: An authorized administrator can issue the DEFINE DBVOLUME  
command to add volumes for use by the database, and can issue the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
ANR2182W  
Unable to update last access date for administrator administrator ID - internal  
server error.  
Explanation: While establishing an administrative session for the indicated ID, the  
server cannot update the administrator’s date of last access due to a server internal  
error.  
System Action: The server establishes the administrative session, but the last  
access date is not updated.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. If the error cannot be isolated and resolved,  
contact your service representative.  
314  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2183W  
ANR2184W  
ANR2185W  
ANR2186W  
DiagnosticID: Transaction transaction ID was aborted.  
Explanation: An error was detected during transaction commit. This message  
should be preceded by other messages that give additional information about the  
failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
DiagnosticID: Transaction transaction ID was aborted for command command.  
Explanation: An error was detected during transaction commit for the specified  
server command. This message should be preceded by other messages that give  
additional information about the failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
Transaction was aborted for command command.  
Explanation: An error was detected during transaction commit. This message  
should be preceded by other messages that give additional information about the  
failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
Transaction was aborted for session session number for node node name (client  
platform).  
Explanation: An error was detected during transaction commit. This message  
should be preceded by other messages that give additional information about the  
failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
Tivoli Storage Manager Messages  
315  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2187W  
ANR2188W  
ANR2189W  
Transaction was aborted for node/admin name.  
Explanation: An error is detected during a transaction commit for the specified  
node or administrator name. This message should be preceded by other messages  
that give additional information about the failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
A Transaction was aborted. The activity is terminating.  
Explanation: An error is detected during a transaction commit. This message  
should be preceded by other messages that give additional information about the  
failed transaction.  
System Action: The activity that generated this error ends.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
DiagnosticID: Transaction transaction ID was aborted for node/admin name.  
Explanation: An error is detected during a transaction commit for the specified  
node or administrator name. This message should be preceded by other messages  
that give additional information about the failed transaction.  
System Action: The activity that generated this error fails.  
User Response: Check for additional messages and eliminate the condition that  
caused the failed transaction. If the error cannot be isolated and resolved, contact  
your service representative.  
ANR2190E  
command: Device class DISK cannot be specified for this command.  
Explanation: The DEVCLASS value DISK cannot be specified for the command.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid device class. Issue the  
QUERY DEVCLASS command for a list of valid device classes for the server.  
ANR2191E  
command: Volume list contains defined and undefined volumes.  
Explanation: The list of volumes specified on the SALVAGE VOLUME command  
must all be defined to the server, or all not defined to the server.  
316  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails and server operation continues.  
User Response: Reissue the command and specify a valid list of volumes.  
ANR2192E  
Command: Unable to start background process.  
Explanation: The server command processor is not able to start a background  
process to perform the command command.  
System Action: The command process ends and server operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2193E  
ANR2194E  
Command: Invalid option set name - option set name.  
Explanation: The command shown specifies an invalid option set name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid option set name.  
Command: Invalid option set description - too long.  
Explanation: The command shown specifies an invalid description. The  
description is too long.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid description.  
ANR2195E  
ANR2196E  
Command: Invalid option sequence number - option sequence number name.  
Explanation: The command shown specifies an invalid option sequence number.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid option sequence number.  
Command: Option name and/or Option value is missing for define.  
Explanation: The specified DEFINE command has been entered, but no attributes  
have been specified for the definition.  
System Action: The server does not process the command.  
User Response: Reissue the DEFINE command with one or more attributes to be  
defined  
Tivoli Storage Manager Messages  
317  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2197E  
ANR2198I  
ANR2199I  
Command: The value supplied for the WEB authentication time out is not valid  
- time-out value.  
Explanation: A SET WEBAUTHTIMEOUT command has been entered that  
specifies a value that is not valid. Valid values are from 0 to 9999, inclusive.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid value.  
Command: Web authentication time-out set to time-out value minutes.  
Explanation: The time-out value that determines how often WEB browser  
administrative users need to re-authenticate with the server has been set with the  
SET WEBAUTHTIMEOUT command to the value displayed.  
System Action: None.  
User Response: None.  
Password expiration period for node node name set to number of days days.  
Explanation: The number of days that the node’s password can be used before it  
must be changed has been set to the value indicated with the SET PASSEXP  
command.  
System Action: None.  
User Response: None.  
ANR2200I  
Storage pool storage pool name defined (device class device class name).  
Explanation: A DEFINE STGPOOL command has created the storage pool  
indicated of the device class shown.  
System Action: None.  
User Response: None.  
ANR2201I  
Storage pool storage pool name deleted.  
Explanation: A DELETE STGPOOL command has deleted the storage pool  
indicated.  
System Action: None.  
User Response: None.  
318  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2202I  
ANR2203I  
ANR2204I  
ANR2205I  
ANR2206I  
Storage pool storage pool name updated.  
Explanation: An UPDATE STGPOOL command has updated the storage pool  
indicated.  
System Action: None.  
User Response: None.  
Device class device class name defined.  
Explanation: A DEFINE DEVCLASS command has created the device class  
indicated.  
System Action: None.  
User Response: None.  
Device class device class name deleted.  
Explanation: A DELETE DEVCLASS command has deleted the device class  
indicated.  
System Action: None.  
User Response: None.  
Device class device class name updated.  
Explanation: An UPDATE DEVCLASS command has updated the device class  
indicated.  
System Action: None.  
User Response: None.  
Volume volume name defined in storage pool storage pool name (device class  
device class name).  
Explanation: A DEFINE VOLUME command has defined the volume indicated in  
the storage pool shown that belongs to the device class shown.  
System Action: None.  
User Response: None.  
ANR2207I  
Volume volume name updated.  
Explanation: An UPDATE VOLUME command has updated the volume  
indicated.  
Tivoli Storage Manager Messages  
319  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR2208I  
Volume volume name deleted from storage pool storage pool name.  
Explanation: The volume indicated has been deleted by one of the following:  
A DELETE VOLUME command was issued.  
The volume was empty and the volume’s access mode was updated to  
destroyed.  
The volume was empty, scratch, and offsite, and the access mode was changed  
to readwrite, readonly, or unavailable.  
The volume was scratch, not offsite, and was emptied by DELETE  
FILESPACE, RECLAMATION, or RESTORE VOLUME/STGPOOL.  
System Action: None.  
User Response: None.  
ANR2209W  
ANR2210I  
ANR2211I  
Volume volume name contains no data.  
Explanation: The AUDIT VOLUME or MOVE DATA command entered specifies  
a volume that contains no data.  
System Action: The server does not process the command.  
User Response: None.  
Vary online initiated for disk volume volume name.  
Explanation: A VARY ONLINE command for the volume shown is being  
processed, and if no errors occur the volume will be varied online.  
System Action: None.  
User Response: None.  
Vary offline initiated for disk volume volume name.  
Explanation: A VARY OFFLINE command for the volume shown is being  
processed and, if no errors occur, the volume will be varied offline.  
System Action: None.  
User Response: None.  
320  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2212I  
Command: No volumes updated.  
Explanation: An UPDATE VOLUME command has been entered, but no objects  
were updated.  
System Action: None.  
User Response: None.  
ANR2213I  
command: Storage pool storage pool name renamed to storage pool name.\n  
Explanation: A RENAME STGPOOL command has been entered. The rename of  
the storage pool was successful.  
System Action: None.  
User Response: None.  
ANR2214E  
ANR2215E  
Command: Invalid backup set name - backup set name.  
Explanation: The command shown specifies an invalid backup set name.  
System Action: The command fails.  
User Response: Reissue the command with a valid backup set name.  
Command: Description text is too long.  
Explanation: The specified description text is too long for a command that allows  
description text to be specified.  
System Action: The command fails  
User Response: Reissue the command specifying a shorter description  
ANR2216E  
Command: Device class is must be a sequential device class.  
Explanation: The device class specified on the command is not a sequential  
device class.  
System Action: The command fails  
User Response: Reissue the command specifying the name of a sequential device  
class  
ANR2217E  
Command: Invalid backup set retention period - retention value.  
Explanation: Server processing for the backup set command command fails  
because the value (retention value) specified for the RETENTION parameter is not  
valid.  
Tivoli Storage Manager Messages  
321  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails  
User Response: Reissue the command specifying a valid RETENTION value.  
ANR2218E  
Command: A device class must be specified.  
Explanation: The DEVCLASS parameter is not specified in the command  
command name. A DEVCLASS value must be specified.  
System Action: The command fails.  
User Response: Reissue the command specifying a valid device class. Issue the  
QUERY DEVCLASS command for a list of valid device classes for the server.  
ANR2219I  
Discard Data process ended for volume volume name - volume is not deleted  
from storage pool storage pool name because the volume access is offsite.  
Explanation: The process that deleted data for the volume shown has ended, but  
the volume has not been deleted because the volume access is marked as offsite.  
System Action: None.  
User Response: To delete the volume, change the volume access to readwrite,  
readonly, or unavailable.  
ANR2220W  
This command will delete volume volume name from its storage pool after  
verifying that the volume contains no data.  
Explanation: A DELETE VOLUME command with the Discarddata=No option  
has been entered.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the DELETE VOLUME command, enter 'Y' to  
continue or 'N' to stop the process.  
ANR2221W  
This command will result in the deletion of all inventory references to the data  
on volume volume name, thereby rendering the data unrecoverable.  
Explanation: A DELETE VOLUME command with the Discarddata=Yes option  
has been entered.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the DELETE VOLUME command, enter 'Y' to  
continue or 'N' to stop the process.  
322  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2222I  
Discard Data process started for volume volume name (process ID process ID).  
Explanation: As a result of a DELETE VOLUME command with the  
Discarddata=Yes option, the process whose ID is displayed has begun to delete the  
data on the volume shown.  
System Action: The server deletes the data on the volume.  
User Response: None.  
ANR2223I  
Discard Data process ended for volume volume name - volume deleted from  
storage pool storage pool name.  
Explanation: The process that deleted data for the volume shown has ended, and  
the volume has been deleted.  
System Action: None.  
User Response: None.  
ANR2224W  
Discard Data process terminated for volume volume name - process canceled.  
Explanation: The process that was deleting data for the volume shown, in  
preparation for deleting the volume, has been canceled.  
System Action: The server does not delete the volume.  
User Response: None.  
ANR2225W  
Discard Data process terminated for volume volume name - volume still contains  
data.  
Explanation: The process that was deleting data for the volume shown, in  
preparation for deleting the volume, has ended. However, the volume contains data.  
System Action: The server does not delete the volume.  
User Response: Contact your service representative.  
ANR2226W  
Discard data process terminated for volume volume name - sufficient recovery  
log space is not available.  
Explanation: The process that was deleting data for the volume shown, in  
preparation for deleting the volume, has ended due to a shortage of recovery log  
space.  
System Action: The server does not delete the volume.  
Tivoli Storage Manager Messages  
323  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: An authorized administrator can issue the DEFINE  
LOGVOLUME command to add volumes for use by the log, and can issue the  
EXTEND LOG command to extend the size of the log so that the new volumes are  
used.  
ANR2227W  
Discard data process terminated for volume volume name - sufficient memory is  
not available.  
Explanation: The process that was deleting data for the volume shown, in  
preparation for deleting the volume, has ended due to a shortage of memory.  
System Action: The server does not delete the volume.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2228W  
Discard data process terminated for volume volume name - lock conflict  
detected.  
Explanation: The process that was deleting data for the volume shown, in  
preparation for deleting the volume, has ended due to a locking conflict.  
System Action: The server does not delete the volume.  
User Response: Reissue the command at a later time. If this problem persists,  
contact your service representative.  
ANR2229W  
Discard data process terminated for volume volume name - internal server error  
detected.  
Explanation: The process that was deleting data for the volume shown, in  
preparation for deleting the volume, has ended due to a server internal error.  
System Action: The server does not delete the volume  
User Response: Contact your service representative.  
ANR2232W  
This command will move all of the data stored on volume volume name to other  
volumes within the same storage pool; the data will be inaccessible to users  
until the operation completes.  
Explanation: A move data has been entered that will move data from the indicated  
volume to other volumes in the same storage pool. While the data is being moved,  
it will not be available to users.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to continue with the command or 'N' to end the process.  
324  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2233W  
This command will move all of the data stored on volume volume name to other  
volumes in storage pool storage pool name; the data will be inaccessible to users  
until the operation completes.  
Explanation: A move data has been entered that will move data from the indicated  
volume to volumes in the storage pool shown. While the data is being moved it will  
not be available to users.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to continue with the command or 'N' to end the process.  
ANR2234W  
This command will halt the server; if the command is issued from a remote  
client, it may not be possible to restart the server from the remote location.  
Explanation: A HALT command has been entered.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to halt the server or 'N' to leave the server activated.  
ANR2235W  
This command will remove administrator adminName. This administrator has  
defined or updated schedules. Removing this authority WILL cause these  
schedules to fail.  
Explanation: A REMOVE ADMINISTRATOR command has been entered for an  
administrator that owns administrative schedules. If you confirm that you want to  
proceed with this command, the schedules owned by this administrator will fail  
when executed in the future.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the REMOVE ADMINISTRATOR command, enter 'Y'  
to continue or 'N' to stop the process. To deal with schedules owneed by the  
administratirr, use the QUERY SCHEDULE command OR an SQL SELECT  
statement on the ADMIN_SCHEDULES table to determine which schedules were  
last updated by the administrator. Use the UPDATE SCHEDULE command to  
update those schedules under an administrator that has authority to execute them, or  
use the DELETE SCHEDULE command to remove the schedules.  
ANR2236W  
This command has removed administrator adminName. This administrator has  
defined or updated schedules. This WILL cause these schedules to fail in the  
future.  
Explanation: A REMOVE ADMINISTRATOR command has been entered and the  
administrator removed owns administrative schedules. The schedules will fail when  
executed in the future because they do not belong to a valid administrator.  
System Action: The system removes the administrator.  
Tivoli Storage Manager Messages  
325  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the QUERY SCHEDULE command OR an SQL SELECT  
statement on the ADMIN_SCHEDULES table to determine which schedules were  
last updated by the administrator. Use the UPDATE SCHEDULE command to  
update those schedules under an administrator that has authority to execute them, or  
use the DELETE SCHEDULE command to remove the schedules.  
ANR2237W  
This command has revoked privileges for administrator adminName. This  
administrator has defined or updated schedules. This may cause these schedules  
to fail in the future.  
Explanation: A REVOKE AUTHORITY command has been entered.  
System Action: The system removes the authority.  
User Response: None.  
ANR2238W  
This command will result in the deletion of all inventory references to the data  
on filespaces that match the pattern filespace name for node node name,  
whereby rendering the data unrecoverable.  
Explanation: A DELETE FILESPACE command has been entered.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the DELETE FILESPACE command, enter 'Y';  
otherwise, enter 'N'.  
ANR2239W  
This command will revoke privileges for administrator adminName. This  
administrator has defined or updated schedules. Revoking this authority may  
cause schedules to fail.  
Explanation: A REVOKE AUTHORITY command has been entered.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the REVOKE AUTHORITY command, enter 'Y' to  
continue or 'N' to stop the process.  
ANR2240I  
Database volume volume name defined.  
Explanation: A DEFINE DBVOLUME command has defined the database volume  
indicated.  
System Action: None.  
User Response: None.  
326  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2241I  
Database volume copy volume name defined.  
Explanation: A DEFINE DBCOPY command has defined the database volume  
indicated.  
System Action: None.  
User Response: None.  
ANR2242I  
Database volume copy volume name defined; synchronization process started  
(process ID process ID).  
Explanation: A DEFINE DBCOPY command has added the volume shown as a  
database copy volume. The process whose ID is displayed will copy data to the new  
volume to synchronize it with existing volumes.  
System Action: None.  
User Response: None.  
ANR2243I  
Database volume volume name deleted.  
Explanation: A DELETE DBVOLUME command has deleted the database  
volume indicated.  
System Action: None.  
User Response: None.  
ANR2244I  
Delete process initiated for database volume volume name (process id process  
ID).  
Explanation: In response to a DELETE DBVOLUME command, the process with  
the process ID shown has been started to delete the volume.  
System Action: None.  
User Response: None.  
ANR2245I  
Database volume volume name varied online.  
Explanation: A VARY ONLINE command has put the database volume indicated  
into an online state.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
327  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2246I  
Vary online process initiated for database volume volume name (process ID  
process ID).  
Explanation: In response to a VARY ONLINE command, the process with the  
process ID shown has been started to vary on the database volume indicated.  
System Action: None.  
User Response: None.  
ANR2247I  
ANR2248I  
ANR2249I  
ANR2250I  
ANR2251I  
Database volume volume name varied offline.  
Explanation: A VARY OFFLINE command has put the indicated database volume  
into an offline state.  
System Action: None.  
User Response: None.  
Database assigned capacity has been extended.  
Explanation: An EXTEND DB command has increased the storage capacity of the  
database.  
System Action: None.  
User Response: None.  
Database extension process initiated (process ID process ID).  
Explanation: In response to an EXTEND DB command, the process with the  
process ID shown has been started to extend the database.  
System Action: None.  
User Response: None.  
Database assigned capacity has been reduced.  
Explanation: A REDUCE DB command has decreased the storage capacity of the  
database.  
System Action: None.  
User Response: None.  
Database reduction process initiated (process ID process ID).  
Explanation: In response to a REDUCE DB command, the process with the  
process ID shown has been started to reduce the database.  
328  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR2252W  
Database volume copy volume name is larger than volume volume name by count  
megabyte(s).  
Explanation: A DEFINE DBCOPY command has defined a database copy volume  
whose size is larger than the volume it mirrors by the amount shown.  
System Action: The excess capacity is ignored.  
User Response: None.  
ANR2253W  
The database volume copy to be defined (volume name) is larger than volume  
volume name; use of the volume will result in count megabyte(s) of unusable  
space.  
Explanation: A DEFINE DBCOPY command is attempting to define a database  
copy volume whose size is larger than the volume it mirrors by the amount shown.  
The excess capacity would not be used.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to define the copy, 'N' otherwise.  
ANR2254E  
Command: The VOLUMENAMES parameter must be specified when  
SCRATCH=NO is specified.  
Explanation: The SCRATCH parameter is specified as NO for the command  
Command but the VOLUMENAMES parameter is not specified. When scratch  
volumes are not allowed, the VOLUMENAMES parameter must be specified to  
indicate the volumes that can be used for the command.  
System Action: The command fails.  
User Response: Reissue the command and specify a valid VOLUMENAMES  
parameter.  
ANR2255E  
Command: The VOLUMENAMES parameter must be specified.  
Explanation: The VOLUMENAMES parameter must be specified to indicate the  
volumes that can be used for the command.  
System Action: The command fails.  
User Response: Reissue the command and specify a valid VOLUMENAMES  
parameter.  
Tivoli Storage Manager Messages  
329  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2256E  
Command: The RETENTION parameter must be specified.  
Explanation: The RETENTION parameter must be specified to indicate the  
retention period to be used for the command.  
System Action: The command fails.  
User Response: Reissue the command and specify a valid RETENTION  
parameter.  
ANR2257E  
Command: Administrator administrator name is not authorized to issue this  
command for node node name.  
Explanation: The specified administrator has entered the indicated command, but  
this administrator does not have the proper authority necessary to run the command  
for the indicated node. Note: This message can be issued as a result of the server  
option REQSYSAUTHOUTFILE YES being in effect.  
System Action: The server does not process the command for the indicated node.  
If multiple nodes were specified on the command, the server may continue  
processing the command for the other nodes.  
User Response: Examine previous messages for any additional information. Issue  
the command from a properly authorized administrator ID, or contact the system  
administrator to have additional authority granted to the current administrator ID.  
ANR2258E  
Command: Invalid summary retention period - retention value.  
Explanation: A SET SUMMARYRETENTION command has been entered that  
specifies an invalid retention period.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid retention period.  
ANR2259I  
Summary retention period set to number of days days.  
Explanation: The number of days that activity sumary records are kept in the  
server database has been set to the value indicated with the SET  
SUMMARYRETENTION command.  
System Action: None.  
User Response: None.  
ANR2260I  
Recovery log volume volume name defined.  
Explanation: A DEFINE LOGVOLUME command has defined the recovery log  
volume indicated.  
330  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR2261I  
Recovery log volume copy volume name defined.  
Explanation: A DEFINE LOGCOPY command has defined the recovery log  
volume indicated.  
System Action: None.  
User Response: None.  
ANR2262I  
Recovery log volume copy volume name defined; synchronization process  
started (process ID process ID).  
Explanation: A DEFINE LOGCOPY command has added the volume shown as a  
log copy volume. The process whose ID is displayed copied data to the new volume  
to synchronize it with existing volumes.  
System Action: None.  
User Response: None.  
ANR2263I  
Recovery log volume volume name deleted.  
Explanation: A DELETE LOGVOLUME command has removed the recovery log  
volume indicated.  
System Action: None.  
User Response: None.  
ANR2264I  
Delete process initiated for recovery log volume volume name (process id process  
ID).  
Explanation: In response to a DELETE LOGVOLUME command, the process  
with process ID shown has been started to delete the volume.  
System Action: None.  
User Response: None.  
ANR2265I  
Recovery log volume volume name varied online.  
Explanation: A VARY ONLINE command has put the recovery log volume  
indicated into an online state.  
System Action: None.  
Tivoli Storage Manager Messages  
331  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2266I  
Vary online process initiated for recovery log volume volume name (process ID  
process ID).  
Explanation: In response to a VARY ONLINE command, the process with process  
ID shown has been started to vary on the recovery log volume indicated.  
System Action: None.  
User Response: None.  
ANR2267I  
ANR2268I  
ANR2269I  
ANR2270I  
Recovery log volume volume name varied offline.  
Explanation: A VARY OFFLINE command has put the recovery log volume  
indicated into an offline state.  
System Action: None.  
User Response: None.  
Recovery log assigned capacity has been extended.  
Explanation: An EXTEND LOG command has increased the storage capacity of  
the recovery log.  
System Action: None.  
User Response: None.  
Recovery log extension process initiated (process ID process ID).  
Explanation: In response to an EXTEND LOG command, the process with the  
process ID shown has been started to extend the recovery log.  
System Action: None.  
User Response: None.  
Recovery log assigned capacity has been reduced.  
Explanation: A REDUCE LOG command has decreased the storage capacity of  
the recovery log.  
System Action: None.  
User Response: None.  
332  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2271I  
Recovery log reduction process initiated (process ID process ID).  
Explanation: In response to a REDUCE LOG command, the process with the  
process ID shown has been started to reduce the recovery log.  
System Action: None.  
User Response: None.  
ANR2272W  
Recovery log volume copy volume name is larger than volume volume name by  
count megabytes.  
Explanation: A DEFINE LOGCOPY command has defined a recovery log copy  
volume whose size is larger than the volume it mirrors by the amount shown.  
System Action: The excess capacity is ignored.  
User Response: None.  
ANR2273W  
The recovery log volume copy to be defined (volume name) is larger than  
volume volume name; use of the volume will result in count megabytes of  
unusable space.  
Explanation: A DEFINE LOGCOPY command is attempting to define a recovery  
log copy volume whose size is larger than the volume it mirrors by the amount  
shown. The excess capacity would not be used.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to define the copy or 'N' to stop the process.  
ANR2274I  
Data Base Space trigger defined and enabled.  
Explanation: The data base space trigger has been defined with a DEFINE  
SPACETRIGGER command. The percentage of utilization specified with the  
FULLPCT parameter is used to automatically expand the data base.  
System Action: None.  
User Response: None.  
ANR2275I  
Data Base Space trigger defined, but is disabled.  
Explanation: A data base space trigger has been defined, but because the space  
expansion percentage is currently set to 0, the space trigger is disabled.  
System Action: None.  
User Response: To activate the space trigger, use the UPDATE SPACETRIGGER  
command to set the space expansion percentage to a value greater than 0.  
Tivoli Storage Manager Messages  
333  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2276I  
Data Base Space trigger updated and enabled.  
Explanation: An UPDATE SPACETRIGGER command has successfully  
completed for the data base space trigger. The updated parameters specified on the  
command are used to automatically trigger space expansion for the data base.  
System Action: None.  
User Response: None.  
ANR2277I  
Data Base Space trigger updated, but disabled.  
Explanation: An UPDATE SPACETRIGGER command has successfully  
completed for the data base space trigger. However, the space expansion percentage  
is currently set to 0, which disables the space trigger.  
System Action: None.  
User Response: To activate the space trigger, use the UPDATE SPACETRIGGER  
command with the SPACE expansion parameter to set a value greater than zero.  
ANR2278I  
ANR2279I  
ANR2280I  
Database Space trigger deleted.  
Explanation: A DELETE SPACETRIGGER command has successfully completed  
for the data base space trigger. Space expansions are no longer triggered  
automatically for the data base.  
System Action: None.  
User Response: None.  
Recovery Log Space trigger defined and enabled.  
Explanation: The recovery log space trigger has been defined with a DEFINE  
SPACETRIGGER command. The percentage of utilization specified with the  
FULLPCT parameter is used to automatically expand the recovery log.  
System Action: None.  
User Response: None.  
Full database backup started as process process ID.  
Explanation: A background process was started to backup the contents of the  
database. The full database backup process was assigned the process ID shown.  
System Action: The database backup process starts and server operation continues.  
334  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The administrator may query the status of the database backup  
process by using the QUERY PROCESS command, or cancel the process with the  
CANCEL PROCESS command.  
ANR2281I  
Incremental database backup started as process process ID.  
Explanation: A background process was started to backup the contents of the  
database. The incremental database backup process was assigned the process ID  
shown.  
System Action: The database backup process starts and server operation continues.  
User Response: The administrator may query the status of the database backup  
process by using the QUERY PROCESS command, or cancel the process with the  
CANCEL PROCESS command.  
ANR2282I  
Database backup trigger defined and enabled.  
Explanation: A database backup trigger has been defined with a DEFINE  
DBBACKUPTRIGGER command. The percentage of recovery log utilization  
specified with the LOGFULLPCT parameter is used to automatically trigger  
database backups.  
System Action: None.  
User Response: None.  
ANR2283I  
Database backup trigger defined, but is disabled.  
Explanation: A database backup trigger has been defined, but because the  
recovery log mode is currently set to NORMAL, the database backup trigger is  
disabled. Database backups can only be triggered when the log mode is set to  
ROLLFORWARD with a SET LOGMODE command.  
System Action: None.  
User Response: To activate the database backup trigger, use the SET LOGMODE  
ROLLFORWARD command.  
ANR2284I  
Database backup trigger updated and enabled.  
Explanation: An UPDATE DBBACKUPTRIGGER command has successfully  
completed. The updated parameters specified on the command are used to  
automatically trigger database backups.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
335  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2285I  
Database backup trigger updated, but disabled.  
Explanation: An UPDATE DBBACKUPTRIGGER command has successfully  
completed, but because the recovery log mode is currently set to NORMAL, the  
database backup trigger is disabled. Database backups can only be triggered when  
the log mode is set to ROLLFORWARD with a SET LOGMODE command.  
System Action: None.  
User Response: To activate the database backup trigger, use the SET LOGMODE  
ROLLFORWARD command.  
ANR2286I  
Database backup trigger deleted.  
Explanation: A DELETE DBBACKUPTRIGGER command has successfully  
completed. Database backups are no longer triggered automatically by recovery log  
utilization.  
System Action: None.  
User Response: None.  
ANR2287I  
Snapshot database backup started as process process ID.  
Explanation: A background process was started to backup the contents of the  
database. The snapshot database backup process was assigned the process id shown.  
System Action: The database backup process starts and server operation continues.  
User Response: The administrator may query the started process by using the  
QUERY PROCESS command, or may cancel the process using the CANCEL  
PROCESS command.  
ANR2288I  
Subfile set to state.  
Explanation: The SET SUBFILE command has been used to specify whether this  
server will allow clients to back up subfiles. If a value of CLIENT is specified,  
clients are given the option of backing up subfiles. If a value of NO is specified,  
clients are not allowed to back up subfiles.  
System Action: None.  
User Response: None.  
ANR2290W  
Changing the log mode to NORMAL will prevent roll-forward recovery.  
Explanation: The system has determined that changing the recovery log mode  
from ROLLFORWARD to NORMAL mode will cause the log records being kept  
336  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
for ROLLFORWARD and single database volume restore processing to be  
discarded. Without these log records, only point-in-time database restores can be  
performed.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to change the LOGMODE, 'N' otherwise.  
ANR2291W  
Changing the log mode to NORMAL will disable the database backup trigger.  
Explanation: Changing the recovery log mode from ROLLFORWARD to  
NORMAL disables the setting specified in the DEFINE DBBACKUPTRIGGER  
command. Database backups can only be triggered when the recovery log mode is  
set to ROLLFORWARD with the SET LOGMODE command.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to change the log mode, 'N' otherwise. Responding 'Y'  
does not delete the DEFINE DBBACKUPTRIGGER settings.  
ANR2292W  
Changing the log mode to ROLLFORWARD will enable the database backup  
trigger.  
Explanation: Changing the recovery log mode from NORMAL to  
ROLLFORWARD causes a previously issued DEFINE DBBACKUPTRIGGER  
command to become effective, and immediately start a full database backup.  
Database backups can only be triggered when the recovery log mode is set to  
ROLLFORWARD with a SET LOGMODE command.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to change the log mode, 'N' otherwise.  
ANR2293I  
Only point-in-time database recovery is now possible.  
Explanation: An administrator has changed the recovery log mode from  
ROLLFORWARD to NORMAL with a SET LOGMODE command. Only  
point-in-time database restores can be performed. ROLLFORWARD database  
restores and individual database volume restores are not possible.  
System Action: None.  
User Response: None.  
ANR2294I  
Log mode set to log mode.  
Explanation: The mode for saving recovery log records has been set as indicated  
by the SET LOGMODE command. When set to NORMAL, only those log records  
needed to resume database processing if a system failure occurs are saved. When set  
Tivoli Storage Manager Messages  
337  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to ROLLFORWARD, all log records created since the last database backup are  
saved. ROLLFORWARD mode also enables the database backup trigger to be used  
to automatically start database backups based on the percentage of recovery log  
utilization.  
System Action: None.  
User Response: None.  
ANR2295I  
Log mode set to ROLLFORWARD; database backup trigger enabled.  
Explanation: The mode for saving recovery log records has been set to  
ROLLFORWARD, and a previously defined database backup trigger has been  
enabled. All log records created since the last database backup are saved in this  
mode. The database backup trigger will automatically start a database backup based  
on the percentage of recovery log utilization.  
System Action: None.  
User Response: None.  
ANR2296I  
Log mode set to NORMAL; database backup trigger disabled.  
Explanation: The mode for saving recovery log records has been set to NORMAL  
mode, and the defined database backup trigger is disabled. Only those log records  
needed to resume database processing if a system failure occurs are saved in this  
mode. Database backups can only be started using the BACKUP DB command.  
System Action: None.  
User Response: None.  
ANR2297I  
Command: Optionset optionset name, option option name, sequence number old  
sequence number, has been changed to new sequence number.  
Explanation: The requested option sequence number has been updated in response  
to an UPDATE CLIENTOPT command.  
System Action: None.  
User Response: None.  
ANR2298I  
Command: Optionset optionset name, option option name, sequence number old  
sequence number, is not updated.  
Explanation: The requested option sequence number is not updated in response to  
an UPDATE CLIENTOPT command.  
System Action: None.  
338  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the UPDATE CLIENTOPT command with a valid old  
sequence number.  
ANR2299I  
Password expiration period for administrator administrator name set to number  
of days days.  
Explanation: The number of days that the administrator’s password can be used  
before it must be changed has been set to the value indicated with the SET  
PASSEXP command.  
System Action: None.  
User Response: None.  
ANR2300E  
ANR2301E  
Could not open file specthe server help file.  
Explanation: The named help file could not be accessed.  
System Action: The requested help text is not displayed.  
User Response: Contact the system administrator.  
Errors were encountered while setting up the index to the help text.  
Explanation: Either insufficient memory or a help file read failure has occurred  
during setup of the help index.  
System Action: The server does not display the requested help text.  
User Response: Contact the system administrator.  
ANR2302E  
The argument operand is not valid for the HELP command.  
Explanation: The argument supplied on the HELP command is not an integer or  
the name of a command.  
System Action: The server does not process the HELP command.  
User Response: Issue the HELP command with no operands and select from the  
numbered list displayed in response.  
ANR2303E  
There is no help section numbered section number.  
Explanation: The numeric operand supplied on the HELP command is either less  
than 1 or greater than the highest-numbered entry in the help index.  
System Action: The server does not process the HELP command.  
User Response: Issue the HELP command with no operands and select from the  
numbered list (help index) displayed in response.  
Tivoli Storage Manager Messages  
339  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2304E  
ANR2305E  
I/O error reading help file namethe file of help text.  
Explanation: An error is detected when reading help text from the named file.  
System Action: The server ends display of the help text.  
User Response: Contact the system administrator.  
No such command/subcommand: command subcommand.  
Explanation: The operands you entered for the HELP command do not match any  
named entry into the file of help text.  
System Action: The server does not process the HELP command.  
User Response: Check your input for a misspelled command or subcommand  
name.  
ANR2306E  
No help text could be found for this command/subcommand: command.  
Explanation: The operands you entered for the HELP command, although valid  
command/subcommand names, do not match any named entry into the file of help  
text.  
System Action: The server does not process the HELP command.  
User Response: Contact the system administrator.  
ANR2307E  
No help text could be found for this message: message ID.  
Explanation: The message ID you entered for the help command does not match  
any message entry in the file of help text.  
System Action: The help command is not processed.  
User Response: Contact the system administrator.  
ANR2308W  
Audit Volume marking damaged file as damaged on volume volume name: Node  
node name, Type file type, File space filespace name, File Name file name.  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=YES for the volume shown, the file whose information is displayed is marked  
as damaged in the server. The file is marked as damaged because it can be  
recovered from a copy known to exist in a COPY storage pool. If this file belongs  
to an aggregate, the entire aggregate is marked damaged, and this message will be  
issued for every file in the aggregate.  
System Action: The file is marked as damaged in the server database.  
340  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: To recover the damaged file use the RESTORE STGPOOL or  
RESTORE VOLUME command.  
ANR2309E  
The server log mode is currently set to roll-forward. You may run out of log  
space when auditing the server in this mode. Specify LOGMODE=NORMAL to  
set the log mode to NORMAL for the audit operation, or  
LOGMODE=ROLLFORWARD to force the audit operation with the logmode  
set to roll-forward.  
Explanation: An AUDITDB operation was specified and the server log mode is  
set to roll-forward mode. When in roll-forward mode, the server may run out of log  
space during the AUDITDB operation, requiring an emergency extend of the  
recovery log to re-start the server. The recommended log mode for executing an  
AUDITDB operation is NORMAL.  
System Action: The AUDITDB operation fails  
User Response: To force the server log mode to NORMAL for the AUDITDB  
operation, specify LOGMODE=NORMAL on the AUDITDB command. Specify  
LOGMODE=ROLLFORWARD on the AUDITDB command to allow the audit to  
run with a roll-forward log mode setting.  
ANR2310W  
This command will compare all inventory references to volume volume name  
with the actual data stored on the volume and will report any discrepancies;  
the data will be inaccessible to users until the operation completes.  
Explanation: During the execution of an AUDIT VOLUME command, any data  
the volume named would be unavailable to users.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to audit the volume or 'N' to stop the process.  
ANR2311W  
This command will discard any inventory references to volume volume name  
associated with missing or inconsistent stored data, thereby rendering the data  
unrecoverable; the valid data on the volume will be inaccessible to users until  
the operation completes.  
Explanation: During the execution of an AUDIT VOLUME command, any data  
the volume named would be unavailable to users. After the command has ended,  
any inconsistent data found will be discarded.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to audit the volume or 'N' to stop the process.  
Tivoli Storage Manager Messages  
341  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2312I  
ANR2313I  
ANR2314I  
Audit Volume (Repair) process started for volume volume name (process ID  
process ID).  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=YES for the volume shown, the process whose ID is displayed has begun  
auditing the volume.  
System Action: The volume is audited and inconsistent data is discarded.  
User Response: None.  
Audit Volume (Inspect Only) process started for volume volume name (process  
ID process ID).  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=NO for the volume shown, the process whose ID is displayed has begun  
auditing the volume.  
System Action: The volume is audited and inconsistent data is displayed.  
User Response: None.  
Audit volume process ended for volume volume name; file count files inspected,  
file count damaged files deleted, file count damaged files marked as damaged.  
Explanation: The AUDIT VOLUME command specifying FIX=YES for the  
volume shown has ended. The number of files audited and the number of  
inconsistent files deleted or marked as damaged are displayed. The number of files  
marked as damaged includes all files belonging to aggregates that were marked  
damaged during the audit. Files are marked as damaged in primary storage pools  
and not deleted when backup copies for the files are known to exist in COPY  
storage pools.  
System Action: None.  
User Response: To recover files that have been marked as damaged on the  
volume, use the RESTORE STGPOOL or RESTORE volume command.  
ANR2315I  
Audit volume process ended for volume volume name; file count files inspected,  
file count damaged files found and marked as damaged.  
Explanation: The AUDIT VOLUME command specifying FIX=NO for the  
volume shown has ended. The number of files audited and the number of  
inconsistent files found are displayed. The number of files marked damaged includes  
all files belonging to aggregates that were marked damaged during the audit.  
Inconsistent files are marked as damaged in the database and can be recovered by  
using the RESTORE STGPOOL or RESTORE VOLUME command if copies of the  
files reside in a COPY storage pool. Another AUDIT VOLUME command may be  
342  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
able to access the files and reset the damaged indicator in the database if the audit  
volume process cannot access the files due to hardware problems (for example, dirty  
tape heads).  
System Action: None.  
User Response: If you suspect that files were inaccessible because of hardware  
problems such as dirty tape heads, correct the hardware problem and reissue the  
AUDIT VOLUME FIX=NO command for this volume. To remove damaged file  
references, issue the AUDIT VOLUME command and specify FIX=YES.  
ANR2316W  
Audit Volume deleting damaged file on volume volume name: Node node name,  
Type file type, File space filespace name, File Name file name.  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=YES for the volume shown, the file whose information is displayed is deleted  
from the server.  
System Action: The file is deleted.  
User Response: None.  
ANR2317W  
Audit Volume found damaged file on volume volume name: Node node name,  
Type file type, File space filespace name, File name file name.  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=NO for the volume shown, the file whose information is displayed is found to  
be in error and not accessible. If this file belongs to an aggregate, the entire  
aggregate is marked damaged, and this message will be issued for every file in the  
aggregate.  
System Action: None.  
User Response: None.  
ANR2318W  
Audit volume process terminated for volume volume name - process canceled.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, the process performing the audit was canceled.  
System Action: The AUDIT VOLUME command is ended.  
User Response: None.  
ANR2319W  
Audit volume process terminated for volume volume name - error reading  
device.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, an unrecoverable read error occurred on the volume.  
Tivoli Storage Manager Messages  
343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The AUDIT VOLUME command is ended.  
User Response: Attempt to correct the cause of the read error, and reissue the  
command.  
ANR2320W  
Audit volume process terminated for volume volume name - data transfer  
interrupted.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, a data transfer operation has been interrupted and cannot be  
continued.  
System Action: The AUDIT VOLUME command is ended.  
User Response: If possible, determine and correct the cause of the interruption,  
and reissue the command.  
ANR2321W  
Audit volume process terminated for volume volume name - storage media  
inaccessible.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, a required volume cannot be mounted.  
System Action: The AUDIT VOLUME command is ended.  
User Response: None.  
ANR2322W  
Audit volume process terminated for volume volume name - sufficient recovery  
log space is not available.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, the server does not have sufficient recovery log space to continue.  
System Action: The AUDIT VOLUME command is ended.  
User Response: If necessary, make more recovery log space available to the  
server.  
ANR2323W  
Audit volume process terminated for volume volume name - sufficient database  
space is not available.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, the server does not have sufficient database space to continue.  
System Action: The AUDIT VOLUME command is ended.  
User Response: If necessary, make more database space available to the server.  
344  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2324W  
Audit volume process terminated for volume volume name - thread resource not  
available.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, the server cannot start a thread for the audit process.  
System Action: The AUDIT VOLUME command is ended.  
User Response: Reissue the AUDIT VOLUME command. If the error persists, it  
may indicate a shortage of server memory.  
ANR2325W  
Audit volume process terminated for volume volume name - sufficient memory  
is not available.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, the server does not have enough memory available to complete the  
command.  
System Action: The AUDIT VOLUME command is ended.  
User Response: If necessary make more memory available to the server.  
ANR2326W  
ANR2327W  
ANR2332W  
Audit volume process terminated for volume volume name - lock conflict  
detected.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, the server cannot obtain a required lock.  
System Action: The AUDIT VOLUME command is ended.  
User Response: Reissue the command.  
Audit volume process terminated for volume volume name - internal server  
error detected.  
Explanation: During processing of an AUDIT VOLUME command for the  
volume shown, an internal server error occurs.  
System Action: The AUDIT VOLUME command is ended.  
User Response: Contact your service representative.  
Object object.ID deleted by another process during execution of an AUDIT  
VOLUME command for volume volume name.  
Explanation: During processing of an AUDIT VOLUME command, a data storage  
object was deleted from the volume that was being audited. The AUDIT VOLUME  
process was unable to locate this object on the specified volume. Normally, this  
Tivoli Storage Manager Messages  
345  
Download from Www.Somanuals.com. All Manuals Search And Download.  
action is not considered an error condition, because the object was probably deleted  
by a process such as a DELETE FILESPACE command.  
System Action: Processing of the AUDIT VOLUME command continues.  
User Response: Check the activity log to verify that some process (such as a  
DELETE FILESPACE command) was in progress during the AUDIT VOLUME  
command that would account for the deleted object. If no such process can be  
identified, contact your service representative.  
ANR2333W  
ANR2334W  
ANR2335W  
Missing or incorrect information detected by AUDIT VOLUME for volume  
volume name.  
Explanation: An AUDIT VOLUME command detects missing or incorrect  
information for the specified volume.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be created or corrected.  
Missing or incorrect information detected by AUDIT VOLUME for volume  
volume name - information will be created or corrected.  
Explanation: An AUDIT VOLUME process detects missing or incorrect  
information for the specified volume. Because FIX=YES has been specified for the  
audit command, the information is created or corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit Volume has encountered an I/O error for volume volume name while  
attempting to read: Node node name, Type file type, Filespace filespace name,  
File Name file name.  
Explanation: The AUDIT VOLUME process encountered an I/O error for the  
specified volume while attempting to read the specified file. If this file belongs to  
an aggregate, the entire aggregate is marked damaged, and this message will be  
issued for every file in the aggregate.  
System Action: None.  
User Response: Identify and resolve the I/O error for the volume if possible.  
Verify that the volume’s device is functioning properly and that the volume is  
usable. For example, if the volume is a tape volume, make sure the drive is clean or  
that the tape volume is usable by testing it by using a different drive.  
346  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2336W  
Audit Volume terminated for volume volume name - insufficient number of  
mount points available for removable media.  
Explanation: During Audit Volume for the indicated volume, the server could not  
allocate sufficient mount points for the volume required.  
System Action: Audit Volume stops.  
User Response: If necessary, make more mount points available.  
ANR2339E  
Command: Object sets still exist for node node name.  
Explanation: A REMOVE NODE command has been entered for a node for  
which the server is still storing backup sets. To remove a node, the node must not  
have any files or backup sets stored on the server.  
System Action: The server does not process the command.  
User Response: To remove the node, delete all backup sets from the server and  
reissue the command.  
ANR2340E  
ANR2341E  
Command: Invalid storage pool name - storage pool name.  
Explanation: The command indicated contains an invalid storage pool name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid storage pool name.  
Command: Missing next storage pool name.  
Explanation: The command indicated requires a storage pool name, but none has  
been entered.  
System Action: The server does not process the command.  
User Response: Reissue the command with a storage pool name.  
ANR2342E  
Command: Storage pool description exceeds maximum characters characters.  
Explanation: The command indicated contains a storage pool description that  
exceeds the maximum length allowed.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid storage pool description.  
Tivoli Storage Manager Messages  
347  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2343E  
ANR2344E  
Command: Invalid device class name - device class name.  
Explanation: The command indicated contains an invalid device class name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid device class name.  
Command: The optionoption is not valid for device class device class name.  
Explanation: The command indicated specifies an option shown that is not valid  
for a storage pool that belongs to the device class shown.  
System Action: The server does not process the command.  
User Response: Reissue the command with options appropriate to the device class.  
ANR2345E  
ANR2346E  
Command: Invalid volume name - volume name.  
Explanation: The command indicated contains an invalid volume name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid volume name.  
Command: Volume name volume nameis not valid for device class device class  
name.  
Explanation: The command indicated specifies the name of a volume that cannot  
be used with the device class shown.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid volume name.  
ANR2347E  
Command: Volume name volume nameis ambiguous; resolves to multiple  
defined volume names.  
Explanation: The command shown was entered with a volume name pattern that  
matches more than one volume. The command can only process a single volume.  
System Action: The command is not executed.  
User Response: Reissue the command with a more specific volume name.  
ANR2348E  
Command: The optionoption is not valid for a volume assigned to a primary  
storage pool.  
Explanation: The command indicated specifies an option that is not valid for a  
volume in a primary storage pool.  
348  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not process the command.  
User Response: Reissue the command with valid options for a volume in a  
primary storage pool.  
ANR2349E  
Command: The optionoption is not valid for a volume assigned to a copy  
storage pool.  
Explanation: The command indicated specifies an option that is not valid for a  
volume in a copy storage pool.  
System Action: The server does not process the command.  
User Response: Reissue the command with valid options for a volume in a copy  
storage pool.  
ANR2350E  
Command: Device class device class name is already defined.  
Explanation: The command indicated has attempted to define a device class that  
already exists.  
System Action: The server does not process the command.  
User Response: None.  
ANR2351E  
ANR2352E  
Command: Device class device class name is not defined.  
Explanation: The command indicated references a device class that does not exist.  
System Action: The server does not process the command.  
User Response: None.  
Command: Device class device class name may not be deleted.  
Explanation: A DELETE DEVCLASS command specifies the class name DISK,  
which is a system-defined device class and may not be deleted.  
System Action: The server does not process the command.  
User Response: None.  
ANR2353E  
Command: Device class device class name may not be updated.  
Explanation: An UPDATE DEVCLASS command specifies the class name DISK,  
which is a system-defined device class and may not be changed.  
System Action: The server does not process the command.  
User Response: None.  
Tivoli Storage Manager Messages  
349  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2354E  
Command: Device class device class name is still referenced by one or more  
storage pools, or database backup or export volumes.  
Explanation: The DELETE DEVCLASS command has attempted to delete a  
device class that has storage pools assigned to it, or is referenced by database  
backup or export volumes.  
System Action: The server does not process the command.  
User Response: Issue Q DEVCLASS to view the storage pool reference count, Q  
STGPOOL to determine which pool references the device class, and Q VOLHIST to  
locate database backup or export volume references.  
ANR2355E  
Command: Required parameter is missing - missing parameter.  
Explanation: The specified server command has been entered without the required  
parameter. The required parameter is shown.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
ANR2356E  
Command: Incompatible parameters specified - first parameter, second  
parameter.  
Explanation: The specified server command has been entered with mutually  
exclusive parameters. The two parameters are listed.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
ANR2357E  
Command: The DISK device class is not supported for copy storage pools.  
Explanation: An attempt is made to define a copy storage pool using a device of  
DISK. Copy storage pools can only be assigned to a sequential device class.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a sequential device class.  
ANR2358E  
Command: Device class device class name is still referenced in the volume  
history file.  
Explanation: The DELETE DEVCLASS command has attempted to delete a  
device class that is associate with entries in the volume history file. These entries  
are for volumes that contain database backup or export data.  
System Action: The server does not process the command.  
350  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the DELETE VOLHIST command to remove that entries  
before deleting the device class.  
ANR2359E  
Command: Volume name volume namemust be specified with a DISK  
STGPOOL.  
Explanation: The command indicated specifies the name of a volume that must be  
specified with a disk storage pool.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid volume name and storage pool.  
ANR2360E  
ANR2361E  
ANR2362E  
Command: Device class device class name may not be used for database backup.  
Explanation: The command specifies the DISK device class, which cannot be  
used for database backup, backup trigger, or restore operations.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid device class.  
Command: A full database backup is required.  
Explanation: A BACKUP DB command specified an incremental backup, but a  
full backup is required.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a full backup.  
Command: Database backup is not currently possible - compressed log records  
exist in the current transaction checkpoint.  
Explanation: A BACKUP DB command was issued but a database backup cannot  
be started. Log compression has recently taken place, and the compressed log  
records are still part of the current transaction checkpoint. After these log records  
are no longer part of the current checkpoint a backup can take place.  
System Action: The server does not process the command.  
User Response: Reissue the command at a later time.  
ANR2363E  
Command: One of the following parameter must be supplied but is missing -  
missing parameter, missing parameter, missing parameter, missing parameter.  
Explanation: The specified server command has been entered without one of the  
mutually exclusive required parameters. One of the parameters from the list must be  
specified.  
Tivoli Storage Manager Messages  
351  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server ignores the command.  
User Response: Reissue the command and enter the proper syntax.  
ANR2364E  
Command: Missing reclaim-storage pool name.  
Explanation: The command indicated requires a storage pool name, but none has  
been entered.  
System Action: The server does not process the command.  
User Response: Reissue the command with a storage pool name.  
ANR2365I  
ANR2366I  
Backupset backup set name for node node name has been deleted.  
Explanation: The backup set has been deleted.  
System Action: The server has deleted the backupset.  
User Response: None.  
Backupset backup set name for node node name would have been deleted.  
Explanation: The backup set would have been deleted as the result of a DELETE  
BACKUPSET command, but the PREVIEW=YES parameter was specified.  
System Action: None.  
User Response: If the backup set is to be deleted, reissue the command without  
specifying PREVIEW=YES.  
ANR2367I  
Retention period for backupset backup set name for node node name has been  
updated.  
Explanation: The backup set’s retention period has been updated.  
System Action: The server has updated the backupset’s retention period.  
User Response: None.  
ANR2368I  
Retention period for backupset backup set name for node node name would have  
been updated.  
Explanation: The backup set’s retention period would have been updated as the  
result of an UPDATE BACKUPSET command, but the PREVIEW=YES parameter  
was specified.  
System Action: None.  
352  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the backup set is to be updated, reissue the command without  
specifying PREVIEW=YES.  
ANR2369I  
Database backup volume and recovery plan file expiration starting under  
process process ID.  
Explanation: The server has started expiration processing to remove expired  
database backup volumes and recovery plan files created on a remote server. This  
message is issued only if DRM is licensed on the server. The DB backup volumes  
expired is based on the value specified on the SET  
DRMDBBACKUPEXPIREDAYS. The recovery plan files expired is based on the  
value specified on the SET DRMRPFEXPIREDAYS. Server inventory expiration  
processing deletes the DB backup volumes and recovery plan files only if the  
volumes or plan files are created on the server to server virtual volumes.  
System Action: Server operation continues. The expiration process is cancellable.  
User Response: None.  
ANR2370E  
Command: Database backup trigger is already defined.  
Explanation: The database backup trigger cannot be defined because it is already  
defined.  
System Action: The server does not process the command.  
User Response: Use the UPDATE DBBACKUPTRIGGER command to modify  
the database backup trigger parameters.  
ANR2371E  
Command: Database backup trigger is not defined.  
Explanation: The database backup trigger cannot be updated or deleted because it  
is not currently defined.  
System Action: The server does not process the command.  
User Response: None.  
ANR2372E  
Command: Data Base Space trigger is already defined.  
Explanation: The database space trigger cannot be defined because it is already  
defined.  
System Action: The server does not process the command.  
User Response: Use the UPDATE SPACETRIGGER command to modify the  
indicated space trigger parameters.  
Tivoli Storage Manager Messages  
353  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2373E  
Command: Database backup trigger is not defined.  
Explanation: The data base space trigger cannot be updated or deleted because it  
is not currently defined.  
System Action: The server does not process the command.  
User Response: None.  
ANR2374E  
Command: Recovery Log Space trigger is already defined.  
Explanation: The recovery log space trigger cannot be defined because it is  
already defined.  
System Action: The server does not process the command.  
User Response: Use the UPDATE SPACETRIGGER command to modify the  
indicated space trigger parameters.  
ANR2375E  
Command: Recovery Log trigger is not defined.  
Explanation: The recovery log space trigger cannot be updated or deleted because  
it is not currently defined.  
System Action: The server does not process the command.  
User Response: None.  
ANR2376I  
Recovery Log Space trigger defined, but is disabled.  
Explanation: A recovery log space trigger has been defined, but because the space  
expansion percentage is currently set to 0, the space trigger is disabled.  
System Action: None.  
User Response: To activate the space trigger, use the UPDATE SPACETRIGGER  
command to set the space expansion percentage to a value greater than 0.  
ANR2377I  
Recovery Log Space trigger updated and enabled.  
Explanation: An UPDATE SPACETRIGGER command has successfully  
completed for the recovery log space trigger. The updated parameters specified on  
the command are used to automatically trigger space expansion for the data base.  
System Action: None.  
User Response: None.  
354  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2378I  
Recovery Log Space trigger updated, but disabled.  
Explanation: An UPDATE SPACETRIGGER command has successfully  
completed for the recovery log space trigger. However, the space expansion  
percentage is currently set to 0, which disables the space trigger.  
System Action: None.  
User Response: To activate the space trigger, use the UPDATE SPACETRIGGER  
command with the SPACEexpansion parameter to set a value greater than zero.  
ANR2379I  
Recovery Log Space trigger deleted.  
Explanation: A DELETE SPACETRIGGER command has successfully completed  
for the recovery log space trigger. Space expansions are no longer triggered  
automatically for the recovery log.  
System Action: None.  
User Response: None.  
ANR2380E  
ANR2381E  
ANR2382E  
Command: Storage pool storage pool name is not defined.  
Explanation: The command indicated specifies the name of a nonexistent storage  
pool.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid storage pool name.  
Command: Storage pool storage pool name is already defined.  
Explanation: A DEFINE STGPOOL command specifies the name of a storage  
pool that already exists.  
System Action: The server does not process the command.  
User Response: None.  
Command: Storage pool storage pool name still contains at least one volume.  
Explanation: A DELETE STGPOOL command specifies a storage pool that has  
volumes assigned to it.  
System Action: The server does not process the command.  
User Response: Delete the volume belonging to the storage pool and reissue the  
command.  
Tivoli Storage Manager Messages  
355  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2383E  
Command: Storage pool storage pool name is currently in use by clients and/or  
data management operations.  
Explanation: The command indicated references a storage pool that is in use.  
System Action: The server does not process the command.  
User Response: Reissue the command at a later time.  
ANR2384E  
Command: Next or Reclaim storage pool storage pool name introduces a cycle  
into the storage pool chain.  
Explanation: A DEFINE STGPOOL or UPDATE STGPOOL command specifies a  
next storage pool that eventually points to the pool being processed.  
System Action: The server does not process the command.  
User Response: Reissue the command with a different next pool value.  
ANR2385E  
Command: Storage pool storage pool name is in use as the next or reclaim pool  
for one or more other storage pools.  
Explanation: A DELETE STGPOOL command specifies a pool that is the next  
pool or the reclaim pool for other storage pools.  
System Action: The server does not process the command.  
User Response: If necessary, update other storage pools so that they do not  
reference the pool to be deleted, and reissue the command.  
ANR2386E  
Command: High migration threshold must be set greater than or equal to the  
low migration threshold.  
Explanation: A DEFINE or UPDATE STGPOOL command has attempted to set  
the storage pool low migration threshold (LOWMIG) parameter greater than the  
high migration threshold (HIGHMIG).  
System Action: The server does not process the command.  
User Response: Reissue the command with a low migration threshold less than or  
equal to the high migration threshold.  
ANR2387E  
Command: Storage pool storage pool name is not a primary pool.  
Explanation: The command indicated specifies the name of a storage pool which  
is not a primary pool. The command syntax requires that a primary storage pool  
name be specified.  
System Action: The server does not process the command.  
356  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command with a valid primary storage pool name.  
ANR2388E  
ANR2389E  
ANR2390E  
ANR2391E  
Command: Storage pool storage pool name is not a copy pool.  
Explanation: The command indicated specifies the name of a storage pool which  
is not a copy pool. The command syntax requires that a copy storage pool name be  
specified.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid copy storage pool name.  
Command: The optionoption is not valid for a primary storage pool.  
Explanation: The command indicated specifies an option that is not valid for a  
primary storage pool.  
System Action: The server does not process the command.  
User Response: Reissue the command with options appropriate for a primary  
storage pool.  
Command: The optionoption is not valid for a copy storage pool.  
Explanation: The command indicated specifies an option that is not valid for a  
copy storage pool.  
System Action: The server does not process the command.  
User Response: Reissue the command with options appropriate for a copy storage  
pool.  
Command: Server could not write device configuration information to file name.  
Explanation: The BACKUP DEVCONFIG command does not successfully  
complete because the server cannot write to the file name specified.  
System Action: The server does not process the command.  
User Response: Make sure that the server has proper authority to write to the file  
indicated and that sufficient space is available in the file system for the file. On  
MVS, make sure that the data set has been allocated and that the server has  
authority to write to the data set.  
ANR2392E  
Command: An internal error was encountered in writing device configuration  
information to file name.  
Explanation: The BACKUP DEVCONFIG command does not successfully  
complete because the server cannot write to the file name specified.  
Tivoli Storage Manager Messages  
357  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not process the command.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems, if possible. Make sure  
that the server has proper authority to write to the file indicated and that sufficient  
space is available in the file system for the file. On MVS, make sure that the data  
set has been allocated and that the server has authority to write to the data set.  
ANR2393I  
Command: Server device configuration information was written to file name.  
Explanation: This message is displayed in response to the BACKUP  
DEVCONFIG command and indicates that device configuration information was  
successfully written to the file name indicated.  
System Action: The server records device configuration information to the file  
name specified  
User Response: None.  
ANR2394I  
Command: Server device configuration information was written to all device  
configuration files.  
Explanation: This message is displayed in response to the BACKUP  
DEVCONFIG command and indicates that device configuration information was  
successfully written to all files that were specified in the server options file.  
System Action: The server records device configuration information to the device  
configuration files.  
User Response: None.  
ANR2395I  
Command: Device configuration files have NOT been defined for automatic  
recording - specify a file name for device configuration information.  
Explanation: This message is displayed in response to the BACKUP  
DEVCONFIG command and indicates that device configuration information cannot  
be written because no files were specified in the options file.  
System Action: The device configuration information is not written. Server  
operation continues.  
User Response: Reissue the BACKUP DEVCONFIG command and specify the  
name of a file to which you would like to have device configuration information  
recorded. If desired, you may configure files that should be automatically updated  
with the DEVCONFIG option and restart the server.  
358  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2396E  
Command: An I/O error was encountered in writing device configuration  
information to one or more of the defined device configuration files.  
Explanation: The BACKUP DEVCONFIG command does not complete  
successfully because the server cannot write to one or more of the defined device  
configuration files.  
System Action: The server does not process the command.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems, if possible. Make sure  
that the server has proper authority to write to the file indicated and that sufficient  
space is available in the file system for the file. On MVS, make sure that the data  
set has been allocated and that the server has authority to write to the data set.  
ANR2397E  
Command: An internal server error was encountered in writing device  
configuration information to one or more of the defined device configuration  
files.  
Explanation: The BACKUP DEVCONFIG command does not complete  
successfully because the server cannot write to one or more of the defined device  
configuration files.  
System Action: The server does not process the command.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems, if possible. Contact your  
service representative if you are unable to resolve the problem.  
ANR2398E  
Command: The device configuration file contains a statement with invalid  
syntax.  
Explanation: While processing the device configuration information, an invalid  
statement has been encountered.  
System Action: The server ends the operation being performed.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems if you have constructed  
the device configuration file manually. Make sure the statements are in the proper  
order. If you let the server construct the device configuration file automatically,  
restart the server, refresh the device configuration file by issuing the BACKUP  
DEVCONFIG command, and reissue the operation. If the problem persists, contact  
your service representative.  
Tivoli Storage Manager Messages  
359  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2399E  
Command: Storage pool storage pool name is not a sequential pool.  
Explanation: The command indicated specifies the name of a storage pool which  
is not a sequential pool. All storage pools are either fixed disk or sequential  
archival. All tape devices, as well as optical and file device classes, are sequential.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid sequential storage pool name.  
ANR2400E  
Command: Volume volume name is already defined in a storage pool or has been  
used previously to store export, database dump, or database backup  
information.  
Explanation: The command indicated specifies the name of a storage pool volume  
that already exists or has been used to store server export, database dump, or  
database backup information as recorded in the server volume history file.  
System Action: The server does not process the command.  
User Response: Specify a volume that is not in use, is not defined in a storage  
pool, and which has not been previously used for an export, a database dump, or  
database backup operation as recorded in the server volume history information. Use  
the QUERY VOLUME command to display the names of volumes that are defined  
to server storage pools. Use the QUERY VOLHISTORY command to display the  
names of volumes that have been used for export, a database dump, or database  
backup operations.  
ANR2401E  
Command: Volume volume name is not defined in a storage pool.  
Explanation: The command indicated specifies the name of a storage pool volume  
that does not exist.  
System Action: The server does not process the command.  
User Response: None.  
ANR2402E  
Command: Volume volume name is already online.  
Explanation: A VARY ONLINE command specifies the name of a volume that is  
already online.  
System Action: The server does not process the command.  
User Response: None.  
360  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2403E  
Command: Volume volume name is not online.  
Explanation: The command indicated specifies the name of a volume that is not  
online.  
System Action: The server does not process the command.  
User Response: None.  
ANR2404E  
Command: Volume volume name is not available.  
Explanation: The command indicated has attempted to access a volume that  
cannot be found.  
System Action: The server does not process the command.  
User Response: Check the spelling of the volume name to ensure it is correct. If  
the volume does not exist, preallocate it with the appropriate mechanism for the  
operating system on which the server is running.  
ANR2405E  
Command: Volume volume name is currently in use by clients and/or data  
management operations.  
Explanation: The command indicated specifies the name of a data storage volume  
that is currently in use.  
System Action: The server does not process the command.  
User Response: None.  
ANR2406E  
Command: Volume volume name still contains data.  
Explanation: The indicated command tries to delete a data storage volume that  
contains data.  
System Action: The server does not process the command.  
User Response: None.  
ANR2407E  
Command: Maximum number of mirrored copies exceeded.  
Explanation: A DEFINE LOGCOPY or DEFINE DBCOPY command has  
attempted to add a mirror volume, but the maximum number of mirrors for the  
target volume already exists.  
System Action: The server does not process the command.  
User Response: None.  
Tivoli Storage Manager Messages  
361  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2408E  
ANR2409E  
ANR2410E  
ANR2411E  
Command: Capacity of volume volume name must be at least as large as  
capacity of volume volume name.  
Explanation: A DEFINE LOGCOPY or DEFINE DBCOPY command has  
attempted to add a mirror volume, but the size of the volume to be added is less  
than the size of the target volume.  
System Action: The server does not process the command.  
User Response: Use a larger mirror volume.  
Command: Capacity of volume volume name must be at least 5 megabytes.  
Explanation: A define command for a database or log volume or copy has  
specified a volume that is too small to be used by the server for a database or log  
volume. The minimum size for one of these volumes is 5 megabytes.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a volume that is at least 5  
megabytes in size.  
Command: Unable to access volume volume name - access mode is set to  
unavailable.  
Explanation: The command shown specifies the volume whose name is displayed,  
but the volume cannot be accessed because its status is unavailable.  
System Action: The server does not process the command.  
User Response: If necessary, reset the status of the volume and reissue the  
command.  
Command: Unable to access associated volume volume name - access mode is set  
to unavailable.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because its status is  
unavailable.  
System Action: The server does not process the command.  
User Response: If necessary, reset the status of the volume and reissue the  
command.  
362  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2412E  
Command: Audit operation already in progress for volume volume name.  
Explanation: The command shown specifies the volume whose name is displayed,  
but that volume is currently in use by an audit volume operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the audit volume operation ends.  
ANR2413E  
Command: Audit operation already in progress for associated volume volume  
name.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because it is in use by an  
audit volume operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the audit volume operation ends.  
ANR2414E  
Command: Deletion operation already in progress for volume volume name.  
Explanation: The command shown specifies the volume whose name is displayed,  
but that volume is currently in use by a delete volume operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the delete volume operation ends.  
ANR2415E  
Command: Deletion operation already in progress for associated volume volume  
name.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because it is in use by a  
delete volume operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the delete volume operation ends.  
ANR2416E  
Command: Move Data operation already in progress for volume volume name.  
Explanation: The command shown specifies the volume whose name is displayed,  
but that volume is currently in use by a move data operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the move data process ends.  
Tivoli Storage Manager Messages  
363  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2417E  
Command: Move Data operation already in progress for associated volume  
volume name.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because it is in use by a  
move data operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the move data operation ends.  
ANR2418E  
Command: Migration operation already in progress for volume volume name.  
Explanation: The command shown specifies the volume whose name is displayed,  
but that volume is currently in use by a migration operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the migration ends.  
ANR2419E  
Command: Migration operation already in progress for associated volume  
volume name.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because it is in use by a  
migration operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the migration ends.  
ANR2420E  
Command: Space reclamation operation already in progress for volume volume  
name.  
Explanation: The command shown specifies the volume whose name is displayed,  
but that volume is currently in use by a reclamation operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the reclamation ends.  
364  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2421E  
Command: Space reclamation operation already in progress for associated  
volume volume name.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because it is in use by a  
reclamation operation.  
System Action: The server does not process the command.  
User Response: Reissue the command after the reclamation ends.  
ANR2422E  
Command: Volume volume name is not a defined disk volume.  
Explanation: The command shown specifies a volume name that does not match  
any known disk volume.  
System Action: The server does not process the command.  
User Response: Reissue the command with the correct volume name.  
ANR2423E  
Command: Volume volume name is still online.  
Explanation: An UPDATE VOLUME command specifies access=unavailable for a  
disk volume that is still online.  
System Action: The server does not process the command.  
User Response: Issue the VARY OFFLINE command, and reissue the UPDATE  
VOLUME command.  
ANR2424E  
Command: Unable to access volume volume name - access mode is set to  
destroyed.  
Explanation: The command shown specifies the volume whose name is displayed,  
but the volume cannot be accessed because its status is destroyed.  
System Action: The server does not process the command.  
User Response: If necessary, reset the status of the volume and reissue the  
command.  
ANR2425E  
Command: Unable to access volume volume name - access mode is set to  
offsite.  
Explanation: The command shown specifies the volume whose name is displayed,  
but the volume cannot be accessed because its status is offsite.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
365  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If necessary, reset the status of the volume and reissue the  
command.  
ANR2426I  
ANR2427E  
Backupset backup set name defined for node node name.  
Explanation: The backup set has been defined for the indicated node.  
System Action: The server has defined the backupset.  
User Response: None.  
Backup set backup set name was not deleted. Device class device class name was  
not found.  
Explanation: The specified backup set was not deleted because the device class  
used to generate it was not found.  
System Action: The backup set is not deleted.  
User Response: If the device class was inadvertently deleted, re-define it, then  
delete the backup set again.  
ANR2429E  
ANR2430E  
ANR2431E  
Command: Maximum database capacity exceeded.  
Explanation: Do not allocate any volume that would cause the database to exceed  
500GB. A subsequent DEFINE DBVOLUME command for that volume would fail.  
System Action: The server does not process the command.  
User Response: None.  
Command: Volume volume name is already defined as a database volume.  
Explanation: A DEFINE DBVOLUME command specifies the name of a database  
volume that already exists.  
System Action: The server does not process the command.  
User Response: None.  
Command: Volume volume name is not a defined database volume.  
Explanation: A DELETE DBVOLUME command specifies the name of a  
database volume that does not exist.  
System Action: The server does not process the command.  
User Response: None.  
366  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2432E  
Command: Maximum number of database volumes exceeded.  
Explanation: A DEFINE DBVOLUME command has attempted to add more  
database volumes than the server can manage.  
System Action: The server does not process the command.  
User Response: None.  
ANR2433E  
Command: A database define, delete, extend, reduce, or backup operation is  
already in progress.  
Explanation: The specified command has been entered while a command that is  
modifying or backing up the database is already active.  
System Action: The server does not process the command.  
User Response: Wait for other activity to end, and reissue the command.  
ANR2434E  
ANR2435E  
ANR2436E  
Command: Insufficient space on other database volumes to delete volume  
volume name.  
Explanation: A DELETE DBVOLUME command has been entered, but the data  
on the volume to be deleted cannot be copied to other volumes due to insufficient  
free space.  
System Action: The server does not process the command.  
User Response: Make more database space available, and reissue the command.  
Command: Unable to delete database volume volume name - mirrored copies not  
synchronized.  
Explanation: A DELETE DBVOLUME command has been entered, but mirrors  
of the volume to be deleted are not up to date.  
System Action: The server does not process the command.  
User Response: Try the command at a later time (after database volumes have  
been synchronized).  
Command: Insufficient space to extend database by requested amount.  
Explanation: An EXTEND DB command has been entered, but not enough  
allocated, unused space is available to the database to add the amount of space  
requested.  
System Action: The server does not process the command.  
User Response: Make more database space available, and reissue the command.  
Tivoli Storage Manager Messages  
367  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2437E  
ANR2438E  
ANR2439E  
Command: Output error encountered while attempting to extend database.  
Explanation: An EXTEND DB command has been entered, but an I/O error  
occurs during the command.  
System Action: The server does not process the command.  
User Response: Reissue the command. If the problem persists, identify and  
remove or repair the volume that caused the error.  
Command: Insufficient database space would be available following a reduction  
by the requested amount.  
Explanation: A REDUCE DB command has been entered, but the database does  
not have enough free space to reduce by the amount specified.  
System Action: The server does not process the command.  
User Response: None.  
Command: Unable to vary database volume volume name offline - mirrored  
copies not synchronized.  
Explanation: A VARY OFFLINE command has been entered, but mirrors of the  
volume to be varied are not up to date.  
System Action: The server does not process the command.  
User Response: Try the command at a later time (after database volumes have  
been synchronized).  
ANR2440E  
Command: Unable to vary database volume volume name offline - only copy.  
Explanation: A VARY OFFLINE command has been entered, but the database  
volume has no mirrors and therefore contains the only copy of the data on that  
volume.  
System Action: The server does not process the command.  
User Response: None.  
ANR2441E  
Command: Volume volume name is already defined as a recovery log volume.  
Explanation: A DEFINE LOGVOLUME command specifies the name of a  
recovery log volume that already exists.  
System Action: The server does not process the command.  
User Response: None.  
368  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2442E  
ANR2443E  
ANR2444E  
Command: Volume volume name is not a defined recovery log volume.  
Explanation: A DELETE LOGVOLUME command specifies the name of a  
recovery log volume that does not exist.  
System Action: The server does not process the command.  
User Response: None.  
Command: Maximum number of recovery log volumes exceeded.  
Explanation: A DEFINE LOGVOLUME command attempts to add more recovery  
log volumes than the server can manage.  
System Action: The server does not process the command.  
User Response: None.  
Command: A recovery log define, delete, extend, or reduce operation is already  
in progress.  
Explanation: The specified command has been entered while a command that is  
modifying the recovery log is already active.  
System Action: The server does not process the command.  
User Response: Wait for other activity to end, and reissue the command.  
ANR2445E  
Command: Insufficient space on other recovery log volumes to delete volume  
volume name.  
Explanation: A DELETE LOGVOLUME command has been entered, but the data  
on the volume to be deleted cannot be copied to other volumes due to insufficient  
free space.  
System Action: The server does not process the command.  
User Response: Make more recovery log space available, and reissue the  
command.  
ANR2446E  
Command: Unable to delete recovery log volume volume name - mirrored copies  
not synchronized.  
Explanation: A DELETE LOGVOLUME command has been entered, but mirrors  
of the volume to be deleted are not up to date.  
System Action: The server does not process the command.  
User Response: Try the command at a later time (after recovery log volumes have  
been synchronized).  
Tivoli Storage Manager Messages  
369  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2447E  
Command: Insufficient space to extend recovery log by requested amount.  
Explanation: An EXTEND LOG command has been entered, but there is not  
enough allocated, unused space available to the recovery log to add the amount of  
space requested.  
System Action: The server does not process the command.  
User Response: Make more recovery log space available, and reissue the  
command.  
ANR2448E  
ANR2449E  
ANR2450E  
Command: Output error encountered while attempting to extend recovery log.  
Explanation: An EXTEND LOG command has been entered, but an I/O error  
occurs during the command.  
System Action: The server does not process the command.  
User Response: Reissue the command. If the problem persists, identify and  
remove or repair the volume that caused the error.  
Command: Insufficient recovery log space would be available following a  
reduction by the requested amount.  
Explanation: A REDUCE LOG command has been entered, but the recovery log  
does not have enough free space to reduce by the amount specified.  
System Action: The server does not process the command.  
User Response: None.  
Command: Unable to vary recovery log volume volume name offline - mirrored  
copies not synchronized.  
Explanation: A DELETE LOGVOLUME command has been entered, but mirrors  
of the volume to be deleted are not up to date.  
System Action: The server does not process the command.  
User Response: Try the command at a later time (after recovery log volumes have  
been synchronized).  
ANR2451E  
Command: Unable to vary recovery log volume volume name offline - only copy.  
Explanation: A VARY OFFLINE command has been entered, but the recovery log  
volume has no mirrors and contains the only copy of the data on that volume.  
System Action: The server does not process the command.  
User Response: None.  
370  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2452E  
Command: Maximum recovery log capacity exceeded.  
Explanation: Do not allocate any volume that would cause the recovery log to  
exceed 5GB. A subsequent DEFINE LOGVOLUME command for that volume  
would fail.  
System Action: The server does not process the command.  
User Response: None.  
ANR2453E  
Command: Unable to reduce recovery log - log mode must be set to NORMAL.  
Explanation: A REDUCE LOG command has been entered, but the recovery log  
mode of the server is currently set to ROLLFORWARD. The recovery log can only  
be reduced when the log mode is set to NORMAL with a SET LOGMODE  
command.  
System Action: The server does not process the command.  
User Response: Set the log mode to NORMAL with the SET LOGMODE  
command, reissue the REDUCE LOG command, and set the log mode back to  
ROLLFORWARD with the SET LOGMODE command. If you change the log mode  
to NORMAL, you can only recover your database to the time of the last complete  
database backup.  
ANR2454E  
Command: Unable to reduce database - LOGMODE must be set to NORMAL.  
Explanation: A REDUCE DB command has been entered, but the recovery log  
mode of the server is currently set to ROLLFORWARD. The database can only be  
reduced when log mode is set to NORMAL with the SET LOGMODE command.  
System Action: The server does not process the command.  
User Response: Set the log mode to NORMAL with the SET LOGMODE  
command, reissue the REDUCE DB command, and reset the log mode to  
ROLLFORWARD with the SET LOGMODE command. If you change the log mode  
to NORMAL, you can only recover your database to the time of the last complete  
database backup.  
ANR2455E  
Command: Unable to access associated volume volume name - access mode is set  
to destroyed.  
Explanation: The specified command would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because its status is  
destroyed.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
371  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If necessary, reset the status of the volume and reissue the  
command.  
ANR2456E  
Command: Unable to access associated volume volume name - access mode is set  
to offsite.  
Explanation: The command shown would require access to the volume whose  
name is displayed (because data from the volume specified in the command spans  
into this volume); the volume shown cannot be accessed because its status is offsite.  
System Action: The server does not process the command.  
User Response: If necessary, reset the status of the volume and reissue the  
command.  
ANR2457E  
Command: Backup of primary storage pool primary pool name to copy storage  
pool copy pool name already in progress.  
Explanation: The command shown specifies a backup operation that is already in  
progress.  
System Action: The server does not process the command.  
User Response: Reissue the command after the current backup operation ends.  
ANR2458E  
Command: Restore of primary storage pool primary pool name (or volumes in  
that storage pool) already in progress.  
Explanation: The command shown cannot be processed because a restore  
operation involving the indicated storage pool is already in progress. Either a  
RESTORE STGPOOL command is in progress for the indicated storage pool or a  
RESTORE VOLUME command is in progress for volumes that belong to the  
indicated storage pool.  
System Action: The server does not process the command.  
User Response: Reissue the command after the current restore operation ends.  
ANR2459E  
Command: Volume volume name cannot be updated - a restore operation  
involving that volume is in progress.  
Explanation: The indicated volume has an access mode of destroyed. Either a  
RESTORE STGPOOL command or a RESTORE VOLUME command is in  
progress to restore the contents of the indicated volume.  
System Action: The server does not process the command.  
User Response: If necessary, cancel the restore processing and update the volume.  
372  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2460E  
Command: Server could not write sequential volume history information to File  
name.  
Explanation: The BACKUP VOLHISTORY command does not complete  
successfully because the server cannot write to the file name specified.  
System Action: The server does not process the command.  
User Response: Make sure that the server has proper authority to write to the file  
indicated and that sufficient space is available in the file system for the file. On  
MVS, make sure that the data set has been allocated and that the server has  
authority to write to the data set.  
ANR2461E  
Command: An internal error was encountered in writing sequential volume  
history information to file name.  
Explanation: The BACKUP VOLHISTORY command does not complete  
successfully because the server cannot write to the file name specified.  
System Action: The server does not process the command.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems, if possible. Make sure  
that the server has proper authority to write to the file indicated and that sufficient  
space is available in the file system for the file. On MVS, make sure that the data  
set has been allocated and that the server has authority to write to the data set.  
ANR2462I  
Command: Server sequential volume history information was written to file  
name.  
Explanation: This message is displayed in response to the BACKUP  
VOLHISTORY command and indicates that sequential volume history information  
was successfully written to the file name indicated.  
System Action: The server records sequential volume history information to the  
file name specified.  
User Response: None.  
ANR2463I  
Command: Server sequential volume history information was written to all  
configured history files.  
Explanation: This message is displayed in response to the BACKUP  
VOLHISTORY command and indicates that sequential volume history information  
was successfully written to all files that were specified in the server options file.  
System Action: The server records sequential volume history information to the  
configured files.  
Tivoli Storage Manager Messages  
373  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2464I  
Command: Volume history files have NOT been defined for automatic history  
recording - specify a file name for recording history information.  
Explanation: This message is displayed in response to the BACKUP  
VOLHISTORY. It indicates that sequential volume history information cannot  
automatically be written because no files were defined in the server options file for  
recording this information.  
System Action: The sequential volume history information is not written. Server  
operation continues.  
User Response: Reissue the BACKUP VOLHISTORY command and specify the  
name of a file for recording sequential volume history information. If desired, you  
may configure files that should be automatically updated with the  
VOLUMEHISTORY parameter and restart the server.  
ANR2465E  
Command: An I/O error was encountered in writing sequential volume history  
information to one or more of the defined volume history files.  
Explanation: The BACKUP VOLHISTORY command does not complete  
successfully because the server cannot write to one or more of the defined volume  
history files.  
System Action: The server does not process the command.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems, if possible. Make sure  
that the server has proper authority to write to the file indicated and that sufficient  
space is available in the file system for the file. On MVS, make sure that the data  
set has been allocated and that the server has authority to write to the data set.  
ANR2466E  
Command: An internal server error was encountered in writing sequential  
volume history information to one or more of the defined volume history files.  
Explanation: The BACKUP VOLHISTORY command does not complete  
successfully because the server cannot write to one or more of the defined volume  
history files.  
System Action: The server does not process the command.  
User Response: Examine error messages on the server console that may have been  
displayed prior to this message and correct any problems, if possible. Contact your  
service representative if you are unable to resolve the problem.  
374  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2467I  
Command: number of entries deleted sequential volume history entries were  
successfully deleted.  
Explanation: The DELETE VOLHISTORY command successfully deleted the  
number of entries specified.  
System Action: Server operation continues.  
User Response: None.  
ANR2468E  
Command: An internal server error was encountered while deleting server  
sequential volume history information.  
Explanation: The DELETE VOLHISTORY command fails because an internal  
server error has been encountered.  
System Action: The DELETE VOLHISTORY command fails, and server operation  
continues.  
User Response: Examine the messages in the activity log or server console that  
were displayed prior to the error to see if the error can be resolved. Contact your  
service representative if this error cannot be resolved.  
ANR2469E  
Command: Invalid volume history type: history type.  
Explanation: The command failed because an invalid sequential volume history  
type was specified for the TYPE= parameter.  
System Action: The command fails, and server operation continues.  
User Response: Refer to the Administrators Reference for an explanation of the  
valid types for this command. Reissue the command and specify a valid type value.  
ANR2470I  
Message output being re-directed to file file name.  
Explanation: The message output is being redirected to the specified file instead  
of being displayed at the console.  
System Action: None.  
User Response: None.  
ANR2471E  
Message output re-direction to file file name failed - unable to open file.  
Explanation: An error occurs while trying to open the file. The message output  
will not be redirected to the specified file.  
System Action: None.  
Tivoli Storage Manager Messages  
375  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Determine the cause of the file open failure and take corrective  
action.  
ANR2472E  
ANR2473I  
ANR2474E  
Command: Invalid volume specified: volume name.  
Explanation: The command failed because the sequential history volume specified  
is not a DB DUMP, DB BACKUP, or EXPORT volume.  
System Action: The command fails, and server operation continues.  
User Response: Reissue the command and specify a valid volume name.  
Command for volume volume name completed.  
Explanation: The command completed and the volume history file has been  
updated.  
System Action: The server records sequential volume history information.  
User Response: None.  
Command: Input volume names must be specified with the VOLumenames=  
parameter.  
Explanation: The command failed because input volume names were not specified  
with the VOLumenames parameter.  
System Action: The command fails.  
User Response: On some platforms, or with certain device classes, the server  
cannot prompt to mount input removable media volumes, so the names of the  
required volumes must be specified in the command. Reissue the command  
specifying the name(s) of volumes that should be mounted for input.  
ANR2475E  
Command: File file name could not be opened.  
Explanation: The DSMSERV command could not be completed successfully  
because the file specified (to contain the list of volumes to be used) cannot be  
opened.  
System Action: The DSMSERV command fails.  
User Response: Examine the file name that was specified in the DSMSERV  
command. Correct the specification, if necessary, so that it specifies the name of a  
file that exists and is accessible by the server program. Reissue the DSMSERV  
command if this can be corrected. Contact your service representative if this error  
cannot be resolved.  
376  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2476I  
License storage auditing is disabled, no output available.  
Explanation: The license storage occupancy function is currently disabled.  
System Action: None.  
User Response: To obtain storage occupancy results, remove the  
NOAUDITSTORAGE or AUDITSTORAGE NO option from the server options file,  
then restart the server and issue the AUDIT LICENSES command.  
ANR2477I  
License storage auditing is disabled, storage values may be outdated and should  
be ignored.  
Explanation: The license storage occupancy function is currently disabled.  
System Action: None.  
User Response: To obtain storage occupancy results, remove the  
NOAUDITSTORAGE or AUDITSTORAGE NO option from the server options file,  
then restart the server and issue the AUDIT LICENSES command.  
ANR2478E  
Command: Command cannot be executed in this session.  
Explanation: The command indicated is not supported by the session in which it  
was invoked. For example, a DEFINE CURSOR command can not be invoked from  
the server’s primary console.  
System Action: The server does not process the command.  
User Response: The command must be issued from a standard administrator  
session.  
ANR2479E  
ANR2480E  
Command: Invalid SQL cursor name - SQL cursor name.  
Explanation: The command indicated contains an invalid SQL cursor name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid SQL cursor name.  
Command: SQL cursor name SQL cursor name is already defined.  
Explanation: The command indicated specifies an SQL cursor name that has  
already been defined.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different cursor name.  
Tivoli Storage Manager Messages  
377  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2481E  
Command: SQL cursor name SQL cursor name is not defined.  
Explanation: The command indicated specifies an SQL cursor name that has not  
been defined.  
System Action: The server does not process the command.  
User Response: Use the DEFINE CURSOR command to first define the cursor.  
ANR2482E  
Command: SQL cursor SQL cursor name is already open.  
Explanation: The command indicated failed because an SQL cursor is already  
open.  
System Action: The server does not process the command.  
User Response: Use the CLOSE CURSOR command to first close the current  
cursor.  
ANR2483E  
Command: No SQL cursor is currently open.  
Explanation: The command indicated failed because no SQL cursor is currently  
open.  
System Action: The server does not process the command.  
User Response: Use the OPEN CURSOR command to first open a cursor.  
ANR2484E  
Command: Invalid SQL date-time display format - SQL date-time display format  
name.  
Explanation: The command indicated contains an invalid SQL date-time display  
format name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid SQL date-time format name.  
ANR2485E  
Command: Invalid SQL display format - SQL display format name.  
Explanation: The command indicated contains an invalid SQL display format  
name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid SQL display format name.  
378  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2486E  
ANR2487E  
ANR2488W  
Command: Invalid SQL character arithmetic mode - SQL arithmetic mode.  
Explanation: The command indicated contains an invalid SQL arithmetic mode  
name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid SQL arithmetic mode name.  
Command: An SQL expression is required.  
Explanation: The command indicated requires that an SQL expression be provided  
through the SQL keyword parameter.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying an SQL expression.  
Volume list file volume list file name could not be opened.  
Explanation: While attempting to read or write a sequential file for volume list  
information, the server cannot open the file name specified.  
System Action: The server does not use the volume list file.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. For OUTFILE files, make sure  
that the server has proper authority to write to the file indicated and that there is  
sufficient space in the file system for the file. On MVS, make sure that the server  
has authority to write to the data set.  
ANR2489W  
An error was encountered writing to volume list file volume list file name.  
Explanation: While attempting to write to the sequential file for a volume list an  
error occurs on the file name specified. The volume list is not be complete and  
should not be used for input.  
System Action: The server stops writing to the file.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated and that there is sufficient space in the  
file system for the file. On MVS, make sure that the server has authority to write to  
the data set. Obtain the volume list from console messages, the QUERY  
VOLHISTORY command or the volume history file, if it is used.  
Tivoli Storage Manager Messages  
379  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2490E  
Command: NODENAMES and SERVERNAMES parameters cannot both be  
specified in the same command.  
Explanation: The command indicated failed because both the nodenames  
parameter and the servernames parameter were specified.  
System Action: None.  
User Response: Determine whether you want the action taken for one or more  
nodes or for one or more servers and re-enter the command with only the correct  
parameter specified.  
ANR2491I  
Volume Creation Process starting for volume name, Process Id process ID.  
Explanation: As a result of a DEFINE VOLUME, DEFINE DBVOLUME, or  
DEFINE LOGVOLUME command with the SIZE=xxx parameter, a new volume is  
being created. The process whose ID is displayed has begun to create the volume  
shown.  
System Action: The server creates the volume and adds it to the server.  
User Response: None.  
ANR2500I  
ANR2501I  
ANR2502I  
Schedule schedule name defined in policy domain domain name.  
Explanation: This message is displayed in response to the DEFINE SCHEDULE  
command. The schedule named schedule name has been defined in the policy  
domain named domain name in the server database.  
System Action: Server operation continues.  
User Response: None.  
Schedule schedule name deleted from policy domain domain name.  
Explanation: This message is displayed in response to the DELETE SCHEDULE  
command. The schedule named schedule name has been deleted from the policy  
domain named domain name in the server database.  
System Action: Server operation continues.  
User Response: None.  
Schedule schedule name updated in policy domain domain name.  
Explanation: This message is displayed in response to the UPDATE SCHEDULE  
command. The schedule named schedule name has been updated in the policy  
domain named domain name in the server database.  
System Action: Server operation continues.  
380  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2503I  
Schedule schedule name in domain domain name copied to schedule new schedule  
name in domain new domain name.  
Explanation: This message is displayed in response to the COPY SCHEDULE  
command. The schedule named schedule name in policy domain domain name has  
been copied to the schedule named new schedule name in the policy domain named  
new domain name. Node associations have not been copied.  
System Action: Server operation continues.  
User Response: None.  
ANR2504I  
Schedule schedule name deleted.  
Explanation: This message is displayed in response to the DELETE SCHEDULE  
command. The schedule named schedule name has been deleted from the server  
database.  
System Action: Server operation continues.  
User Response: None.  
ANR2505I  
number of schedules schedules were defined for command.  
Explanation: number of schedules were generated and nodes successfully  
associated for the command issued.  
System Action: Server operation continues.  
User Response: If the number is less than expected, check the nodeList and  
domainList combination specified to the DEFINE CLIENTACTION command.  
Schedules are generated when at least one node in the nodeList exists in a domain  
in the domainList.  
ANR2506I  
Node node name associated with schedule schedule name in policy domain  
domain name processed. rc=return code.  
Explanation: This message is displayed in response to the DEFINE  
CLIENTACTION WAIT=YES command. Node node name is associated with the  
schedule named schedule name in policy domain domain name has been processed.  
name The result is indicated in the return code return code.  
System Action: Server operation continues.  
User Response: If the return code is non-zero, issue the QUERY ACTLOG  
command to to view the activity log and search for the error messages. After the  
error has been resolved, restart the scheduled operations.  
Tivoli Storage Manager Messages  
381  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2510I  
Node node name associated with schedule schedule name in policy domain  
domain name.  
Explanation: This message is displayed in response to the DEFINE  
ASSOCIATION command. Node node name is associated with the schedule named  
schedule name in policy domain domain name. Schedule schedule name is now  
applied to node node name.  
System Action: Server operation continues.  
User Response: None.  
ANR2511I  
Node node name disassociated from schedule schedule name in policy domain  
domain name.  
Explanation: This message is displayed in response to the DELETE  
ASSOCIATION command. Node node name is no longer associated with the  
schedule named schedule name in policy domain domain name.  
System Action: Server operation continues.  
User Response: None.  
ANR2512I  
ANR2513I  
ANR2520I  
Event records deleted: record count.  
Explanation: This message is displayed in response to the DELETE EVENT  
command. A total of record count event records have been deleted from the  
database.  
System Action: Server operation continues.  
User Response: None.  
Schedule schedule name copied to schedule new schedule name.  
Explanation: This message is displayed in response to the COPY SCHEDULE  
command. The schedule named schedule name has been copied to the schedule  
named new schedule name.  
System Action: Server operation continues.  
User Response: None.  
Scheduled sessions set to percent percent.  
Explanation: This message is displayed in response to the SET  
MAXSCHEDSESSIONS command. It indicates the percentage of total server  
sessions that can be used for the processing of scheduled work.  
System Action: Server operation continues.  
382  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2521I  
ANR2522I  
ANR2523I  
Event record retention period set to days days.  
Explanation: This message is displayed in response to the SET  
EVENTRETENTION command. It indicates the number of days for which event  
records are retained in the database.  
System Action: Server operation continues.  
User Response: None.  
Randomization set to percent percent.  
Explanation: This message is displayed in response to the SET RANDOMIZE  
command. It indicates the percentage of the startup window over which the start  
times for individual clients are distributed.  
System Action: Server operation continues.  
User Response: None.  
Schedule query period set to hours hour(s).  
Explanation: This message is displayed in response to the SET  
QUERYSCHEDPERIOD command. It indicates the number of hours between  
attempts by the client to contact the server for scheduled commands.  
System Action: Server operation continues.  
User Response: None.  
ANR2524I  
Schedule query period reset to value determined by each client.  
Explanation: This message is displayed in response to the SET  
QUERYSCHEDPERIOD command.  
System Action: Server operation continues.  
User Response: None.  
ANR2525I  
Maximum number of command retries set to retries.  
Explanation: This message is displayed in response to the SET  
MAXCMDRETRIES command. It indicates the maximum number of times the  
client scheduler retries a command after a failed attempt to process a scheduled  
command.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
383  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2526I  
Maximum number of command retries reset to value determined by each  
client.  
Explanation: This message is displayed in response to the SET  
MAXCMDRETRIES command.  
System Action: Server operation continues.  
User Response: None.  
ANR2527I  
Retry period set to minutes minutes.  
Explanation: This message is displayed in response to the SET RETRYPERIOD  
command. It indicates the number of minutes between attempts by the client  
scheduler to retry, after a failed attempt, to contact the server or to process a  
scheduled command.  
System Action: Server operation continues.  
User Response: None.  
ANR2528I  
Retry period reset to value determined by each client.  
Explanation: This message is displayed in response to the SET RETRYPERIOD  
command.  
System Action: Server operation continues.  
User Response: None.  
ANR2529I  
Scheduling mode set to POLLING.  
Explanation: This message is displayed in response to the SET SCHEDMODES  
command. With client-polling scheduling, a client queries the server at prescribed  
time intervals to obtain scheduled work or to ensure that the schedules the client is  
waiting to process have not changed.  
System Action: Server operation continues.  
User Response: None.  
ANR2530I  
Scheduling mode set to PROMPTED.  
Explanation: This message is displayed in response to the SET SCHEDMODES  
command. With server-prompted scheduling, the server contacts the client when  
scheduled work needs to be performed and a session is available.  
384  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: None.  
ANR2531I  
ANR2532I  
ANR2533I  
Scheduling mode set to ANY.  
Explanation: This message is displayed in response to the SET SCHEDMODES  
command. The server now allows clients to run in either the client-polling or the  
server-prompted scheduling mode.  
System Action: Server operation continues.  
User Response: None.  
Schedule schedule name updated.  
Explanation: This message is displayed in response to the UPDATE SCHEDULE  
command. The schedule named schedule name has been updated in the server  
database.  
System Action: Server operation continues.  
User Response: None.  
Client action schedule duration set to days days.  
Explanation: This message is displayed in response to the Set  
CLIENTACTDuration command. It indicates the number of days for which  
schedules and associations generated by the DEFine CLIENTAction are retained in  
the database.  
System Action: Server operation continues.  
User Response: None.  
ANR2534I  
Client action schedule schedule name was not executed by node name in domain  
name.  
Explanation: Immediate client action schedule name was not executed by node  
node name, which is in domain domain name. The schedule is being deleted.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
385  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2550W  
command name: Administrative schedule schedule name does not have valid  
activation information.  
Explanation: This message is displayed during a database audit and indicates that  
the ’ACTIVE=YES or NO’ information is not recorded correctly for an  
administrative schedule in the server database.  
System Action: Server database audit operation continues.  
User Response: Execute the AUDITDB operation specifying FIX=YES so that the  
activation information can be corrected.  
ANR2551I  
command name: Administrative schedule schedule name does not have valid  
activation information - activation information will be deleted.  
Explanation: This message is displayed during a database audit and indicates that  
the ’ACTIVE=YES or NO’ information is not recorded correctly for an  
administrative schedule in the server database. The audit operation corrects this  
discrepancy by removing the invalid activation information.  
System Action: Server database audit operation continues.  
User Response: The named administrative schedule will now appear to be inactive  
in the server database (as if ACTIVE=NO was specified). If you want this schedule  
to be active, execute the UPDATE SCHEDULE command with the ACTIVE=YES  
parameter to activate the schedule when the server is restarted.  
ANR2560I  
Schedule manager started.  
Explanation: The schedule manager is started when the server is initialized. The  
schedule manager maintains entries of scheduled operations.  
System Action: Server operation continues.  
User Response: None.  
ANR2561I  
Schedule prompter contacting node name (session session number) to start a  
scheduled operation.  
Explanation: The schedule prompter contacts the client scheduler for node node  
name because a scheduled operation should be started for that node.  
System Action: Server operation continues.  
User Response: None.  
386  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2562I  
ANR2563I  
ANR2564I  
ANR2565I  
ANR2566E  
Automatic event record deletion started.  
Explanation: A process has been started to delete event records for which the  
retention period has elapsed.  
System Action: Server operation continues.  
User Response: None.  
Removing event records dated prior to date time.  
Explanation: Events that were scheduled to start prior to date time are  
automatically deleted unless their startup window has not yet elapsed.  
System Action: Server operation continues.  
User Response: None.  
Automatic event record deletion ended - record count records deleted.  
Explanation: The event deletion process has ended. A total of record count event  
records have been deleted from the database.  
System Action: Server operation continues.  
User Response: None.  
schedules schedules for immediate client actions have been deleted.  
Explanation: A total of schedules that were generated by the DEFINE  
CLIENTACTION command have expired and been deleted from the database.  
System Action: Server operation continues.  
User Response: None.  
An error occurred while deleting immediate client action schedules.  
Explanation: Processing did not complete for deleting schedules that were  
generated by the DEFINE CLIENTACTION command.  
System Action: Server operation continues.  
User Response: Check the activity log for other messages that might relate to this  
failure. Correct any memory or space problems.  
ANR2570W  
A scheduled session has been denied. The schedule manager is not active.  
Explanation: The client scheduler attempts to connect with the server, but it is  
denied a session because the schedule manager is not active.  
Tivoli Storage Manager Messages  
387  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but central scheduling is not  
operational.  
User Response: Issue the QUERY OPTION command to determine if the option  
DISABLESCHEDS YES has been specified in the server options file. If so,  
scheduling can be enabled by updating the server options file with  
DISABLESCHEDS NO and restarting the server. If DISABLESCHEDS YES was  
not specfied in the server options file, determine the source of the error by  
examining the QUERY ACTLOG command to view the activity log and search for  
messages. After the error has been resolved, restart the server to restore central  
scheduler operations. If the error cannot be isolated and resolved, contact your  
service representative.  
ANR2571W  
Scheduled session from node node name (platform name) has been denied,  
scheduled sessions are not currently available.  
Explanation: The client scheduler for node node name attempts to connect with  
the server, but is denied a session. All sessions that have been allocated for  
scheduled operations are already in use.  
System Action: Server operation continues.  
User Response: Issue the QUERY OPTION command to determine if the option  
DISABLESCHEDS YES has been specified in the server options file. If so,  
scheduling can be enabled by updating the server options file with  
DISABLESCHEDS NO and restarting the server. If DISABLESCHEDS YES was  
not specfied in the server options file, change the total number of sessions by  
altering the MAXSESSIONS parameter in the server options file and then restarting  
the server. The percentage of sessions that are available for scheduled operations can  
be increased by using the SET MAXSCHEDSESSIONS command.  
ANR2572W  
Schedule prompter session to node node name has been denied, scheduled  
sessions are not currently available.  
Explanation: The server attempts to prompt the client scheduler for node node  
name, but all sessions that have been allocated for scheduled operations are already  
in use.  
System Action: The server continues to attempt contact with the client scheduler  
until the startup window for the scheduled event has elapsed.  
User Response: To change the total number of sessions, alter the MAXSESSIONS  
parameter in the server options file and then restart the server. The percentage of  
sessions that are available for scheduled operations can be increased by using the  
SET MAXSCHEDSESSIONS command.  
388  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2573W  
Sufficient memory is not available for the central scheduler - will retry in  
number of seconds seconds.  
Explanation: The server suspends central scheduler processing because sufficient  
server memory is not available.  
System Action: Server operation continues; the scheduler operation will be retried  
after the specified delay.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2574W  
Insufficient recovery log space available for the central scheduler - will retry in  
number of seconds seconds.  
Explanation: The server suspends central scheduler processing because sufficient  
recovery log space is not available.  
System Action: Server operation continues; the scheduler operation will be retried  
after the specified delay.  
User Response: To increase the amount of log space available to the server, an  
authorized administrator can add log volumes by using the DEFINE LOGVOLUME  
command, and can extend the size of the log by using the EXTEND LOG  
command.  
ANR2575W  
Insufficient database space available for the central scheduler - will retry in  
number of seconds seconds.  
Explanation: The server suspends central scheduler processing because sufficient  
database space is not available.  
System Action: Server operation continues; the scheduler operation will be retried  
after the specified delay.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes by using the DEFINE  
DBVOLUME command, and can extend the size of the log by using the EXTEND  
DB command.  
ANR2576W  
An attempt was made to update an event record for a scheduled operation  
which has already been executed - multiple client schedulers may be active for  
node node name.  
Explanation: The server has attempted to update an event record for a scheduled  
operation for the specified client node. However, the existing event record shows  
Tivoli Storage Manager Messages  
389  
Download from Www.Somanuals.com. All Manuals Search And Download.  
that this scheduled operation has already been executed, either successfully or  
unsuccessfully. Two or more client schedulers may be running for this node.  
System Action: Server operation continues. The existing event record is not  
modified. No further processing is performed for this scheduled operation.  
User Response: Contact the user for this client node, and make sure that only one  
client scheduler is running.  
ANR2577I  
Schedule schedule name defined.  
Explanation: This message is displayed in response to the DEFINE SCHEDULE  
command. The schedule named schedule name in the server database.  
System Action: Server operation continues.  
User Response: None.  
ANR2578I  
Schedule schedule name in domain domain name for node node name has missed  
its scheduled start up window.  
Explanation: This message is displayed when the scheduled startup window for  
this schedule has passed and the schedule has not begun.  
System Action: Server operation continues. The scheduled operation is not  
processed by the server.  
User Response: Ensure that a scheduled session for node node name has been  
initiated from the client to the server. Refer to Administrators Guide and  
Administrators Reference for more information on setting up scheduling operations.  
ANR2579E  
Schedule schedule name in domain domain name for node node name failed  
(return code return code).  
Explanation: This message is displayed when a client reports failure in executing  
a scheduled action. The return code reported by the client is displayed.  
System Action: Server operation continues.  
User Response: Examine the node’s schedule log to determine the cause for the  
failure.  
ANR2580E  
Schedule schedule name in domain domain name for node node name failed.  
Explanation: This message is displayed when the server finds that a scheduled  
start window has elapsed for a client schedule and the client is not currently running  
the schedule.  
System Action: Server operation continues.  
390  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the node’s schedule log to determine the cause for the  
failure. Ensure that the client scheduler is started.  
ANR2600E  
Command: Invalid schedule name - schedule name.  
Explanation: The specified command has been issued with an invalid schedule  
name.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid schedule name.  
ANR2601E  
Command: Schedule description exceeds maximum length characters.  
Explanation: The specified command has been issued with a description that  
exceeds the maximum length.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid description.  
ANR2602E  
ANR2603E  
Command: Invalid action - action.  
Explanation: The specified command has been issued with an invalid action.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid action.  
Command: Options string exceeds maximum length characters.  
Explanation: The specified command has been issued with an options string that  
exceeds the maximum length.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid options string.  
ANR2604E  
Command: Objects string exceeds maximum length characters.  
Explanation: The specified command has been issued with an objects string that  
exceeds the maximum length.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid objects string.  
Tivoli Storage Manager Messages  
391  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2605E  
ANR2606E  
ANR2607E  
ANR2608E  
ANR2609E  
Command: Invalid priority - priority.  
Explanation: The specified command has been issued with an invalid priority.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid priority.  
Command: Invalid start date - date.  
Explanation: The specified command has been issued with an invalid start date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid start date.  
Command: Invalid start time - time.  
Explanation: The specified command has been issued with an invalid start time.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid start time.  
Command: Invalid duration - duration.  
Explanation: The specified command has been issued with an invalid duration.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid duration.  
Command: Invalid duration units - duration units.  
Explanation: The specified command has been issued with an invalid value for  
duration units.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid value for duration units.  
ANR2610E  
Command: Invalid period - period.  
Explanation: The specified command has been issued with an invalid period.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid period.  
392  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2611E  
ANR2612E  
ANR2613E  
ANR2614E  
Command: Invalid period units - period units.  
Explanation: The specified command has been issued with an invalid value for  
period units.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid value for period units.  
Command: Invalid day of week - day of week.  
Explanation: The specified command has been issued with an invalid value for  
day of the week.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid value for day of the week.  
Command: Invalid expiration - date.  
Explanation: The specified command has been issued with an invalid expiration  
date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid expiration date.  
Command: Invalid combination of the following parameters: duration, duration  
units, period, period units.  
Explanation: The specified command has been issued with an invalid combination  
of the DURATION, DURUNITS, PERIOD, and PERUNITS parameters. This  
message may be displayed if the duration of the startup window for the schedule is  
not shorter than the period between windows. This message may also be displayed  
if DURUNITS=INDefinite is specified, but PERUNITS=Onetime is not specified.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid combination of  
parameters.  
ANR2615E  
Command: Expiration date date has elapsed.  
Explanation: The specified command has been issued with an elapsed expiration  
date date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify an expiration date that has not  
already elapsed.  
Tivoli Storage Manager Messages  
393  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2616E  
ANR2617E  
ANR2618E  
Command: Start date start date must be earlier than expiration date expiration.  
Explanation: The specified command has been issued with a start date that is not  
earlier than the expiration date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command using a schedule start date that is earlier than  
the expiration date.  
Command: Schedule schedule name is not defined in policy domain domain name.  
Explanation: The specified command has been issued with a schedule name that  
has not been defined in the indicated policy domain.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command using a schedule that has already been defined  
for this domain.  
Command: Schedule schedule name is already defined in policy domain domain  
name.  
Explanation: The specified command has been issued with a schedule name that  
has already been defined for the indicated policy domain.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command using a schedule that has not already been  
defined for this domain.  
ANR2619E  
Command: Currently defined period period is invalid with updated period units.  
Explanation: The specified command has been issued with a value for period  
units that is not allowed with the existing period.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a new period.  
ANR2620E  
Command: Currently defined duration duration is invalid with updated duration  
units.  
Explanation: The specified command has been issued with a value for duration  
units that is not allowed with the existing duration.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a new duration.  
394  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2621E  
ANR2622E  
ANR2623E  
Command: No matching schedules.  
Explanation: The specified command has been issued but no matching schedules  
have been found.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify different schedules.  
Command: No new node associations added.  
Explanation: The specified command has been issued but no new node  
associations are defined.  
System Action: Server operation continues, but the command has no effect.  
User Response: Issue the command and specify different nodes.  
Command: No node associations deleted.  
Explanation: The specified command has been issued but no node associations are  
deleted.  
System Action: Server operation continues, but the command has no effect.  
User Response: Issue the command and specify different nodes.  
ANR2624E  
ANR2625E  
Command: No matching nodes registered.  
Explanation: No matching nodes are found for the specified command.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify different nodes.  
Command: No matching nodes registered in policy domain domain name.  
Explanation: The specified command has been issued, but no matching nodes are  
registered in the indicated policy domain.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify different nodes.  
ANR2626E  
Command: Invalid value for replace - replace.  
Explanation: The specified command has been issued with an invalid value for  
replace.  
System Action: Server operation continues, but the command is not processed.  
Tivoli Storage Manager Messages  
395  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command using a valid value for replace.  
ANR2627E  
Command: Invalid value for format - format.  
Explanation: The specified command has been issued with an invalid value for  
format.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command using a valid value for format.  
ANR2628E  
ANR2629E  
ANR2630E  
Command: Invalid date - date.  
Explanation: The specified command has been issued with an invalid date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid date.  
Command: Invalid time - time.  
Explanation: The specified command has been issued with an invalid time.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid time.  
Command: Event deletion is already in process.  
Explanation: The specified command has been issued while event deletion is  
already in progress.  
System Action: Server operation continues, but the command is not processed.  
User Response: Wait for event deletion to complete before issuing the command.  
ANR2631E  
ANR2632E  
Command: Invalid begin date - date.  
Explanation: The specified command has been issued with an invalid begin date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid begin date.  
Command: Invalid begin time - date.  
Explanation: The specified command has been issued with an invalid begin time.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid begin time.  
396  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2633E  
ANR2634E  
ANR2635E  
Command: Invalid end date - date.  
Explanation: The specified command has been issued with an invalid end date.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid end date.  
Command: Invalid end time - time.  
Explanation: The specified command has been issued with an invalid end time.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid end time.  
Command: Invalid time range - Begin: begin End: end.  
Explanation: The specified command has been issued with an invalid time range.  
This occurs if the date and time for the beginning of the time range (begin) do not  
precede the date and time for the end of the time range (end).  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid time range.  
ANR2636E  
Command: Invalid value for exceptions only - exceptions only.  
Explanation: The specified command has been issued with an invalid value for  
exceptions only.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value for exceptions only.  
ANR2640E  
ANR2641E  
Command: Invalid percentage of sessions for scheduled processing - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Command: Invalid event record retention period - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Tivoli Storage Manager Messages  
397  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2642E  
ANR2643E  
ANR2644E  
ANR2645E  
ANR2646E  
ANR2647E  
Command: Invalid percentage for randomization - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Command: Invalid schedule query period - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Command: Invalid maximum number of command retries - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Command: Invalid retry period - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Command: Invalid scheduling mode - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid value.  
Command: Invalid type - type.  
Explanation: The specified command has been issued with an invalid type.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid type.  
398  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2648E  
ANR2649E  
ANR2650E  
Command: Type string exceeds maximum length characters.  
Explanation: The specified command has been issued with a type string that  
exceeds the maximum length.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid type string.  
Command: Schedule schedule name is not defined.  
Explanation: The specified command has been issued with a schedule name that  
has not been defined.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a schedule that has already been defined.  
Command: Schedule schedule name is already defined.  
Explanation: The specified command has been issued with a schedule name that  
has already been defined.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a schedule name that has not already  
been defined.  
ANR2651E  
Command: Invalid combination of one or more of the following parameters:  
cmd, type, action, objects, options.  
Explanation: The specified command has been issued with an invalid combination  
of the CMD, ACTION, OBJECTS, and OPTIONS parameters. This message is  
displayed when the CMD parameter is specified and TYPE=CLIENT is not  
specified, or when TYPE=ADMIN is specified, and one or more of the following is  
specified: ACTION, OBJECTS, or OPTIONS.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command with a valid combination of parameters.  
ANR2652E  
Command: Invalid combination of one or more of the following parameters:  
active, cmd, type.  
Explanation: The specified command has been issued with an invalid combination  
of the TYPE, CMD, or ACTIVE parameters. This message is displayed when  
TYPE=CLIENT is specified and one or more of the following is specified:  
ACTIVE, CMD.  
System Action: Server operation continues, but the command is not processed.  
Tivoli Storage Manager Messages  
399  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command with a valid combination of parameters.  
ANR2653W  
Command: Node node name cannot be processed because it is not registered or  
does not belong to the specified domain.  
Explanation: This command cannot be processed for the indicated node. Either  
the node is not registered or it is not assigned to the required domain.  
System Action: The indicated node is not processed, but other nodes may be  
processed if specified by this command.  
User Response: If the node name was entered incorrectly, reissue the command  
with the correct node name.  
ANR2654E  
Command: The NODES parameter cannot be used when querying  
administrative schedules.  
Explanation: A QUERY SCHEDULE command has been issued with  
TYPE=ADMINISTRATIVE and the NODES parameter both specified. The NODES  
parameter cannot be specified when querying administrative schedules.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command without the NODES parameter.  
ANR2655E  
Command: Invalid client action schedule duration - days.  
Explanation: The specified command has been issued with an invalid number of  
days. Valid values are 1 to 9999 inclusive. days specifies the length of time during  
which a schedule defined by the DEFine CLIENTAction command must be  
executed by an associated node. After that, the schedule will be deleted from the  
database.  
System Action: Server operation continues, but the command is not processed.  
User Response: Reissue the command with a valid number of days.  
ANR2700E  
Schedule manager aborted.  
Explanation: The schedule manager has ended because of an error condition and  
is not able to maintain entries for scheduled operations.  
System Action: Server operation continues, but the central scheduler is not  
operational.  
User Response: To determine the source of the error, examine server messages  
issued prior to this message. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. After the error has been resolved, restart the  
400  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
server to restore central scheduler operations. If the error cannot be isolated and  
resolved, contact your service representative.  
ANR2701E  
ANR2702E  
ANR2703E  
The schedule manager could not be started: diagcode.  
Explanation: The schedule manager cannot be started during initialization because  
sufficient memory is not available. Diagnostic code diagcode is issued.  
System Action: Initialization fails.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
The schedule prompter could not be started: diagcode.  
Explanation: The schedule prompter cannot be started during initialization because  
sufficient memory is not available. Diagnostic code diagcode is issued.  
System Action: Initialization fails.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
Schedule prompter aborted.  
Explanation: The schedule prompter ends because of a processing error.  
System Action: Server operation continues, but prompted scheduling is not  
operational.  
User Response: To determine the source of the error, examine server messages  
issued prior to this message. Issue the QUERY ACTLOG command to view the  
activity log and search for messages. After the error has been resolved, restart the  
server to restore central scheduler prompting operations. If the error cannot be  
isolated and resolved, contact your service representative.  
ANR2707E  
Out of server log space in central scheduler.  
Explanation: The server ends a database update transaction for the central  
scheduler because sufficient log space is not available on the server.  
System Action: Server operation continues, but the database update fails.  
User Response: An authorized administrator can use the DEFINE LOGVOLUME  
command to add volumes for use by the log and can issue the EXTEND LOG  
command to extend the size of the log so that the new volumes are used.  
Tivoli Storage Manager Messages  
401  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2708E  
Out of server database space in central scheduler.  
Explanation: The server ends a database update transaction for the central  
scheduler because sufficient database space is not available on the server.  
System Action: Server operation continues, but the database update fails.  
User Response: An authorized administrator can use the DEFINE DBVOLUME  
command to add volumes for use by the database and can use the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
ANR2709E  
Schedule manager: Unable to start event record deletion.  
Explanation: Event record deletion cannot be started because sufficient memory is  
not available.  
System Action: Server operation continues, but event records are not automatically  
deleted after their retention period has elapsed.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2712E  
Node node1 requested scheduling information for node node2 - session rejected.  
Explanation: A request for pending scheduled operations has been sent from the  
client scheduler for node node1. However, the request is for scheduling information  
concerning another node node2.  
System Action: Server operation continues, but the client scheduler for node  
node1 will not be able to process pending operations.  
User Response: Try restarting the client scheduler for node node1. If the problem  
persists, contact your service representative to resolve the client program error.  
ANR2713E  
Node node1 trying to start scheduled operation for node node2 - session  
rejected.  
Explanation: The client scheduler for node node1 has attempted to execute a  
scheduled operation for another node, node2.  
System Action: Server operation continues, but the scheduled operation is not  
processed.  
User Response: Try restarting the client scheduler for node node1. If the problem  
persists, contact your service representative to resolve client program error.  
402  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2714E  
Node node1 trying to report scheduled operation results for node node2 -  
session rejected.  
Explanation: The client scheduler for node node1 has attempted to report the  
results of a scheduled operation using another node name, node2.  
System Action: Server operation continues, but the results that were sent from  
node node1 are not be stored in the server’s database.  
User Response: Try restarting the client scheduler for node node1. If the problem  
persists, contact your service representative to resolve the client program error.  
ANR2715E  
Client node node name unable to register valid address for server prompting:  
type address type (high address low address).  
Explanation: The client scheduler for node node name has attempted to register an  
invalid address for server-prompted central scheduling. The address was type  
address type with high-level field high address and low-level field low address. The  
only valid address type is 1.  
System Action: Server operation continues, but the node node name will not be  
prompted to perform scheduled operations.  
User Response: Verify that the address type and address are correct for this client.  
The only valid address type is 1 (for TCP/IP). Make sure the client scheduler is not  
using an invalid address obtained from the client’s options file or from the  
command line when the client scheduler was started.  
ANR2716E  
Schedule prompter was not able to contact client node name using type address  
type (high address low address).  
Explanation: The server has attempted to prompt the client scheduler for node  
node name because a scheduled operation should be started. The server is unable to  
contact the client by using address type address type, with high-level field high  
address and low-level field low address.  
System Action: Server operation continues, but node node name is not prompted  
to start the scheduled operation. If operations should be started for other nodes, the  
server will attempt to prompt the client schedulers for these nodes. This error is  
usually caused by network outages or the client scheduler program not being run on  
the client node.  
User Response: Verify that the address type and address are correct for this client.  
The only valid address type is 1 (for TCP/IP). Make sure the client scheduler is not  
using an invalid address, obtained at the time the client scheduler was started, from  
either the client’s options file or from the command line. Verify that the client  
scheduler for node node name is running and that the necessary communication  
links to that scheduler are operational.  
Tivoli Storage Manager Messages  
403  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2717E  
Schedule prompter cannot contact client node name using address type (address  
type).  
Explanation: The server attempts to prompt the client scheduler for node node  
name because scheduled work should be started. However, either the server does not  
support address type address type needed for server-prompted scheduling, or the  
communication method is not currently available. The only valid address type is 1  
(for TCP/IP).  
System Action: Server operation continues, but the server does not prompt node  
node name.  
User Response: If the server does not support the address type specified, clients  
may only use the polling mode of scheduling. If the communication method is  
temporarily not available, prompted mode scheduling will resume after the  
communication problem is fixed and service restored. If the problem persists,  
contact your service representative.  
ANR2718W  
Schedule manager disabled.  
Explanation: The schedule manager has been disabled because the  
DISABLESCHEDS YES option was specified in the server options file.  
System Action: Server operation continues, but the central scheduler is not  
operational.  
User Response: To enable the schedule manager, specify DISABLESCHEDS NO  
in the server options file and restart the server.  
ANR2750I  
Starting scheduled command schedule name ( scheduled command ).  
Explanation: This message is displayed when the server starts the execution of a  
scheduled command. The name of the schedule and the actual command scheduled  
is displayed.  
System Action: Server operation continues, the scheduled command is processed.  
User Response: None.  
ANR2751I  
Scheduled command schedule name completed successfully.  
Explanation: This message is displayed when the server successfully completes  
processing of a scheduled command.  
System Action: Server operation continues.  
User Response: None.  
404  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2752E  
Scheduled command schedule name failed.  
Explanation: This message is displayed when the server encounters a failure in  
processing a scheduled command.  
System Action: Server operation continues. The scheduled command is ended.  
User Response: Examine messages issued prior to this message and use the  
UPDATE SCHEDULE command to correct the scheduled command. The QUERY  
EVENT command may also be used to determine the cause of the failure for this  
scheduled command.  
ANR2753I  
ANR2754E  
ANR2755E  
ANR2756I  
(Schedule name):command response  
Explanation: This message is used to display the server response to a scheduled  
command. The name of the command schedule is included at the beginning of the  
message in parentheses.  
System Action: Server operation continues. The scheduled command is ended.  
User Response: None.  
DEFINE SCHEDULE or UPDATE SCHEDULE parameter CMD=’command’ -  
Unknown command.  
Explanation: The specified command is not a valid server command.  
System Action: The DEFINE SCHEDULE or UPDATE SCHEDULE command is  
not processed.  
User Response: Reissue the correct command.  
DEFINE SCHEDULE or UPDATE SCHEDULE parameter CMD=’command’ -  
not eligible for scheduling.  
Explanation: The specified command is not eligible for scheduling.  
System Action: The DEFINE SCHEDULE or UPDATE SCHEDULE command is  
not processed.  
User Response: None.  
Scheduled command schedule name started successfully.  
Explanation: This message is displayed when the server successfully starts  
processing of a background process for a scheduled command.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
405  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2757E  
ANR2780W  
ANR2800E  
Command: The NODES parameter cannot be used when querying events for  
administrative schedules.  
Explanation: A QUERY EVENT command has been issued with  
TYPE=ADMINISTRATIVE and the NODES parameter both specified. The NODES  
parameter cannot be specified when querying events for administrative schedules.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command without the NODES parameter.  
Command: Updates for nodes previously processed during this command will be  
rolled back.  
Explanation: An error has occurred during an UPDATE NODE operation. If the  
UPDATE NODE command was processing more than one node, updates for nodes  
which were previously processed will be rolled back.  
System Action: Server operation continues.  
User Response: Correct the error and reissue the command.  
The license manager cannot be started: diagcode.  
Explanation: The license manager cannot be started during initialization because  
sufficient memory is not available. Diagnostic code diagcode is issued.  
System Action: Initialization fails.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2803I  
License manager started.  
Explanation: The license manager is started when the server is initialized. The  
license manager monitors license compliance.  
System Action: Server operation continues.  
User Response: None.  
ANR2804W  
Insufficient memory is available for the license manager - will retry in number  
of seconds seconds.  
Explanation: The server suspends license manager processing because sufficient  
server memory is not available.  
System Action: Server operation continues; the license manager operation will be  
retried after the specified delay.  
406  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2805W  
Insufficient recovery log space available for the license manager - will retry in  
number of seconds seconds.  
Explanation: The server suspends license manager processing because sufficient  
recovery log space is not available.  
System Action: Server operation continues; the license manager operation will be  
retried after the specified delay.  
User Response: To increase the amount of log space available to the server, an  
authorized administrator can add log volumes using the DEFINE LOGVOLUME  
command, and can extend the size of the log using the EXTEND LOG command.  
ANR2806W  
Insufficient database space available for the license manager - will retry in  
number of seconds seconds.  
Explanation: The server suspends license manager processing because sufficient  
database space is not available.  
System Action: Server operation continues; the license manager operation will be  
retried after the specified delay.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes using the DEFINE  
DBVOLUME command, and can extend the size of the log using the EXTEND DB  
command.  
ANR2807E  
Out of server log space in license manager.  
Explanation: The server ends a database update transaction for the license  
manager because sufficient recovery log space is not available on the server.  
System Action: Server operation continues, but the database update fails.  
User Response: An authorized administrator can use the DEFINE LOGVOLUME  
command to add volumes for use by the log and can issue the EXTEND LOG  
command to extend the size of the log so that the new volumes are used.  
ANR2808E  
Out of server database space in license manager.  
Explanation: The server ends a database update transaction for the license  
manager because sufficient database space is not available on the server.  
System Action: Server operation continues, but the database update fails.  
Tivoli Storage Manager Messages  
407  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: An authorized administrator can use the DEFINE DBVOLUME  
command to add volumes for use by the database and can use the EXTEND DB  
command to extend the size of the database so that the new volumes are used.  
ANR2811I  
Audit License completed - Server is in compliance with license terms.  
Explanation: The results from the AUDIT LICENSES command indicate the  
server is in compliance with the terms of the current license.  
System Action: Server operation continues.  
User Response: None.  
ANR2812W  
License Audit completed - ATTENTION: Server is NOT in compliance with  
license terms.  
Explanation: The results from the AUDIT LICENSES command indicate the  
server is not in compliance with the terms of the current license.  
System Action: Server operation continues, but the REGISTER NODE command  
or backup-archive requests, or both, will fail.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance.  
ANR2813I  
Server is licensed for a capacity of capacity gigabytes and number of clients  
clients.  
Explanation: This message is issued during server startup.  
System Action: Server operation continues.  
User Response: None.  
ANR2814I  
Audit command: License audit period changed to number of days days.  
Explanation: This message is displayed in response to the SET  
LICENSEAUDITPERIOD command used to change the interval in days between  
automatic license audits.  
System Action: Server processing continues.  
User Response: None.  
ANR2815E  
Command: Invalid value specified for interval between license audits - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
408  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command with a valid value.  
ANR2816E  
ANR2817I  
Command: License audit operation already in progress.  
Explanation: The server is currently performing a license audit.  
System Action: The server does not process the specified command.  
User Response: Reissue the command after the license audit process ends.  
Command: License audit started as process process ID.  
Explanation: A background process has been started to audit the server for license  
compliance.  
System Action: The server checks the existing configuration for the server and  
compares it against the values for which the server is licensed.  
User Response: The administrator may query the status of the background process  
by using the QUERY PROCESS command, or cancel the process with the CANCEL  
PROCESS command.  
ANR2818I  
Command: Licensed capacity is capacity GB with number of clients clients.  
Explanation: This message displays the license information that existed before  
issuing the REGISTER LICENSE command.  
System Action: None.  
User Response: None.  
ANR2819I  
Command: Licensed capacity changed to capacity GB with number of clients  
clients.  
Explanation: The license information has been changed to the indicated values  
with the REGISTER LICENSE command.  
System Action: None.  
User Response: To implement the changed license information, issue an AUDIT  
LICENSES command or wait until an automatic license audit occurs.  
ANR2820I  
Automatic license audit started as process process ID.  
Explanation: A background process has been started to audit the server for license  
compliance.  
Tivoli Storage Manager Messages  
409  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server checks storage utilization and registered nodes for the  
server and licensed factors, comparing these against the values for which the server  
is licensed.  
User Response: The administrator may query the status of the background process  
using the QUERY PROCESS command.  
ANR2821E  
Automatic license audit could not be started: diagcode.  
Explanation: The license manager cannot start an automatic process to audit  
server licenses because sufficient memory is not available. Diagnostic code diagcode  
is issued.  
System Action: Server processing continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR2822I  
Cancel in progress  
Explanation: The license audit operation has been cancelled and will end when  
resources have been freed for the background process. This message may be  
displayed in response to a QUERY PROCESS command for an AUDIT LICENSES  
operation.  
System Action: Server operation continues.  
User Response: None.  
ANR2823I  
Have audited number of nodes nodes  
Explanation: An AUDIT LICENSES operation is in progress. The process has  
audited the specified number of nodes. This message may be displayed in response  
to a QUERY PROCESS command for an AUDIT LICENSES operation.  
System Action: Server operation continues.  
User Response: None.  
ANR2824I  
License audit process process number canceled - number of nodes nodes audited.  
Explanation: A background server process to audit server licenses has been  
canceled by using the CANCEL PROCESS command. The number of nodes that  
have been audited before the operation ended are reported in the message.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
410  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2825I  
License audit process process number completed successfully - number of nodes  
nodes audited.  
Explanation: A background server process to audit server licenses has completed  
successfully after auditing the specified number of nodes.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
ANR2826I  
License audit process process number terminated in error - number of nodes  
nodes audited.  
Explanation: A background server process to audit server licenses encounters an  
error and is ended. The number of nodes that have been audited before the operation  
ended is reported in the message.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
ANR2832I  
Command: The License Manager has not yet completed initialization - please  
retry this command later.  
Explanation: While attempting to process the specified license command, the  
server detects that the licensing component of the server had not completed  
initialization. The licensing facility used on some platforms may require some time  
to initialize because network calls are involved, and waits may occur.  
System Action: Server operation continues; the command is not processed.  
User Response: Reissue the command after waiting 10 minutes. If this message is  
displayed after a number of retry attempts, contact your service representative.  
ANR2833I  
Command: Auditing license definitions.  
Explanation: The server has started to audit database definitions that describe  
licensing information.  
System Action: Server database audit operation continues.  
User Response: None.  
ANR2834W  
License Audit completed - WARNING: Server is NOT in compliance with  
license terms.  
Explanation: The results from the AUDIT LICENSES command indicate that the  
server is not in compliance with the terms of the current license.  
Tivoli Storage Manager Messages  
411  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but the REGISTER NODE command  
fails.  
User Response: Use the QUERY LICENSE command to determine the license  
terms that are no longer in compliance. Remove nodes or purchase additional client  
node connections. After these actions have been taken, reissue the AUDIT  
LICENSES command to resynchronize the server configuration with license terms.  
ANR2836I  
Command: License audit started as process process ID.  
Explanation: A background process has been started to audit the server for license  
compliance.  
System Action: The server checks registered nodes for the server and compares  
this against the value for which the server is licensed.  
User Response: The administrator may query the status of the background process  
using the QUERY PROCESS command, or cancel the process with the CANCEL  
PROCESS command.  
ANR2839I  
Automatic license audit started as process process ID.  
Explanation: A background process has been started to audit the server for license  
compliance.  
System Action: The server checks registered nodes and compares them against the  
value for which the server is licensed.  
User Response: The administrator may query the status of the background process  
by using the QUERY PROCESS command.  
ANR2841W  
Server is NOT IN COMPLIANCE with license terms.  
Explanation: This message is issued periodically when the server configuration  
does not comply with the terms for which it is licensed.  
System Action: Server operation continues.  
User Response: Use the QUERY LICENSE command to display the current server  
configuration with respect to licensed terms to discover which factors of the  
configuration do not conform to your license. Contact your service representative to  
obtain more licenses, if required.  
ANR2852I  
Current license information:  
Explanation: This message is issued during a REGISTER LICENSE command to  
display the current licensing information for the server before the new license has  
been interpreted by the command. Messages appearing after this message display  
the factors under which the server is currently licensed.  
412  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: None.  
ANR2853I  
New license information:  
Explanation: This message is issued during a REGISTER LICENSE command to  
display the updated licensing information for the server after the new license has  
been interpreted by the command. Messages appearing after this message display  
the updated factors under which the server is licensed.  
System Action: Server operation continues.  
User Response: Check to make sure that the new license information includes the  
updates that you intended for the REGISTER LICENSE command. If the license  
terms do not change, check the parameters and reissue the command, if you find  
that it was not entered correctly. If the REGISTER LICENSE command does not  
produce the desired updates in terms of licensing, contact your service  
representative.  
ANR2855I  
ANR2860I  
ANR2900W  
Server is licensed to support Tivoli Space Manager clients.  
Explanation: This message is issued during server startup.  
System Action: Server operation continues.  
User Response: None.  
Server is licensed to support Tivoli Disaster Recovery Manager.  
Explanation: This message is issued during server startup.  
System Action: Server operation continues.  
User Response: None.  
The character string ’string’ was truncated during assignment.  
Explanation: Truncation occurred during assignment of an SQL character string.  
For example, the expression CAST( ’Hello’ AS CHAR(2) ) will result in truncation  
because the string ’Hello’ (length 5) can not fit in the target type CHAR(2) without  
loss of trailing characters.  
System Action: This warning can occur before or after SQL query processing, but  
does not terminate query processing.  
User Response: None.  
Tivoli Storage Manager Messages  
413  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2901W  
The result of character string concatenation was truncated.  
Explanation: Truncation occurred when the concatenation of character strings  
resulted in a length that exceeds the maximum character string length (250 for data  
type CHAR, and 2000 for data type VARCHAR).  
System Action: This warning can occur before or after SQL query processing, but  
does not terminate query processing.  
User Response: None.  
ANR2902E  
Insufficient memory was available to process the SQL statement.  
Explanation: Sufficient memory was not available to complete the processing of  
an SQL query.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2903E  
An SQL parser stack overflow occurred while processing token ’token’.  
Explanation: The internal stack used by the SQL query parser has overflowed.  
This typically occurs when too many column names or expressions have been  
specified in the SELECT clause.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2904E  
Unexpected SQL key word token - ’token’.  
Explanation: A syntax error occurred because an SQL key word was found that  
can not legally be used at the specified position within the SQL statement.  
Examples of SQL key words are SELECT, FROM, and WHERE.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2905E  
Unexpected SQL identifier token - ’token’.  
Explanation: A syntax error occurred because an SQL identifier was found that  
can not legally be used at the specified position within the SQL statement.  
Examples of SQL identifiers are table names and column names.  
System Action: The SQL query is terminated.  
User Response: None.  
414  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2906E  
ANR2907E  
ANR2908E  
Unexpected SQL literal token - ’token’.  
Explanation: A syntax error occurred because an SQL literal token was found that  
can not legally be used at the specified position within the SQL statement.  
Examples of SQL literal tokens are ’abc’, 1.567, and DATE ’1/1/96’.  
System Action: The SQL query is terminated.  
User Response: None.  
Unexpected SQL operator token - ’token’.  
Explanation: A syntax error occurred because an SQL operator token was found  
that can not legally be used at the specified position within the SQL statement.  
Examples of SQL operator tokens are +, *, <, and =.  
System Action: The SQL query is terminated.  
User Response: None.  
Unexpected SQL punctuation token - ’token’.  
Explanation: A syntax error occurred because an SQL punctuation token was  
found that can not legally be used at the specified position within the SQL  
statement. Examples of SQL punctuation tokens are the period, the comma, and the  
parenthesis.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2909E  
The SQL statement is incomplete; additional tokens are required.  
Explanation: A syntax error occurred because, although the syntax of the SQL  
query expression was correct up to the end of the string, the parser expected  
additional tokens in order to form a syntactically-correct SQL statement.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2910E  
Invalid SQL token - ’token’.  
Explanation: An invalid SQL token was found. For example, the token formed by  
the character sequence ::!is not a valid SQL token.  
System Action: The SQL query is terminated.  
User Response: None.  
Tivoli Storage Manager Messages  
415  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2911E  
Invalid SQL numeric literal token - ’token’.  
Explanation: An invalid SQL numeric literal token was found. For example, the  
floating point literal 1.456Eis not valid.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2912E  
Invalid character string literal token - ’token’.  
Explanation: An invalid SQL character string literal token was found. For  
example, the hexadecimal literal X’78FG’ is not valid because it contains the  
character ’G’.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2913E  
ANR2914E  
ANR2915E  
Invalid SQL identifier token - ’token’.  
Explanation: An invalid SQL identifier token was found. For example, the  
character sequence ABC.123is not a valid identifier because the second part of  
the identifier, 123, does not begin with a letter.  
System Action: The SQL query is terminated.  
User Response: None.  
SQL identifier token ’token’ is too long; name or component exceeds 18  
characters.  
Explanation: An SQL identifier token was found that exceeds the maximum  
length of 18 characters per component.  
System Action: The SQL query is terminated.  
User Response: None.  
The SQL token beginning with ’token’ is missing an ending delimiter.  
Explanation: An SQL token was found that is missing its ending delimiter. For  
example, each of the tokens ’abc, abc, and X’abc is missing its ending delimiter.  
System Action: The SQL query is terminated.  
User Response: None.  
416  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2916E  
The SQL data types data type and data type are incompatible for operator  
operator’.  
Explanation: The data types of the operands are not compatible when used with  
the specified operator. For example, the expression 3 + ’abc’ is not valid because  
the operand data types INTEGER and CHAR(3) are not compatible for the addition  
operator +.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2917E  
The SQL data type of expression ’expression’ is data type; expecting an integer  
expression.  
Explanation: An SQL expression of data type SMALLINT, INTEGER, or  
DECIMAL with scale zero is expected.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2918E  
The SQL data type of expression ’expression’ is data type; expecting a Boolean  
expression.  
Explanation: An SQL expression of data type BOOLEAN is expected.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2919E  
The SQL data type of expression ’expression’ is data type; expecting a numeric  
expression.  
Explanation: An SQL expression of numeric data type SMALLINT, INTEGER,  
DECIMAL, NUMERIC, REAL, FLOAT, or DOUBLE_PRECISION is expected.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2920E  
The SQL data type of expression ’expression’ is data type; expecting a numeric  
or interval expression.  
Explanation: An SQL expression of numeric data type (SMALLINT, INTEGER,  
DECIMAL, NUMERIC, REAL, FLOAT, DOUBLE) or of interval data type  
(INTERVAL) is expected.  
System Action: The SQL query is terminated.  
Tivoli Storage Manager Messages  
417  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2921E  
The SQL data type of expression ’expression’ is data type; expecting a character  
string expression.  
Explanation: An SQL expression of character string type CHAR or VARCHAR is  
expected.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2922E  
The SQL data type of expression ’expression’ is data type; expecting a date,  
timestamp, character string date, character string timestamp, or interval  
expression.  
Explanation: An SQL expression was expected of one of the types DATE,  
TIMESTAMP, CHAR, VARCHAR, or INTERVAL as the operand to the EXTRACT  
function. In the case of CHAR or VARCHAR, the expression must be a valid  
character string representation of a date or a timestamp.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2923E  
The SQL data type of expression ’expression’ is data type; expecting a time,  
timestamp, character string time, character string timestamp, or interval  
expression.  
Explanation: An SQL expression was expected of one of the types TIME,  
TIMESTAMP, CHAR, VARCHAR, or INTERVAL as the operand to the EXTRACT  
function. In the case of CHAR or VARCHAR, the expression must be a valid  
character string representation of a time or a timestamp.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2924E  
The SQL data type of expression ’expression’ is data type; expecting a date or  
character string date expression.  
Explanation: An SQL expression was expected of one of the types DATE, CHAR,  
or VARCHAR. In the case of CHAR or VARCHAR, the expression must be a valid  
character string representation of a date.  
System Action: The SQL query is terminated.  
User Response: None.  
418  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2925E  
ANR2926E  
ANR2927E  
The SQL data type of expression ’expression’ is data type; expecting a time or  
character string time expression.  
Explanation: An SQL expression was expected of one of the types TIME, CHAR,  
or VARCHAR. In the case of CHAR or VARCHAR, the expression must be a valid  
character string representation of a time.  
System Action: The SQL query is terminated.  
User Response: None.  
The SQL data type of expression ’expression’ is data type; expecting a date,  
timestamp, character string date, or character string timestamp expression.  
Explanation: An SQL expression was expected of one of the types DATE,  
TIMESTAMP, CHAR, or VARCHAR. In the case of CHAR or VARCHAR, the  
expression must be a valid character string representation of a date or a timestamp.  
System Action: The SQL query is terminated.  
User Response: None.  
The SQL data type of expression ’expression’ is data type; expecting an interval  
containing a single date-time field.  
Explanation: An SQL expression was expected of data type INTERVAL YEAR,  
INTERVAL MONTH, INTERVAL DAY, INTERVAL HOUR, INTERVAL MINUTE,  
or INTERVAL SECOND, all of which contain a single date-time field. Multi-field  
interval types (for example, INTERVAL DAY TO SECOND) are not allowed.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2928E  
A number can not be converted to SQL data type INTERVAL if the interval  
contains multiple date-time fields.  
Explanation: An attempt was made to convert a number to the data type  
INTERVAL, but the target interval contains multiple date-time fields (for example,  
INTERVAL DAY TO SECOND). Only the single-field interval types INTERVAL  
YEAR, INTERVAL MONTH, INTERVAL DAY, INTERVAL HOUR, INTERVAL  
MINUTE, or INTERVAL SECOND can be specified.  
System Action: The SQL query is terminated.  
User Response: None.  
Tivoli Storage Manager Messages  
419  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2929E  
ANR2930E  
ANR2931E  
The expression ’expression’ is not an integer constant.  
Explanation: An integer constant such as 1 or -9 is expected. For example, the  
DECIMAL function requires that the precision and scale operands be integer  
constants. A decimal constant such as 1.67 is not valid.  
System Action: The SQL query is terminated.  
User Response: None.  
A subquery used in an SQL expression must specify a single result column.  
Explanation: A subquery used in an expression can not specify multiple result  
columns. For example, the expression X > (select A,B from T) is invalid because it  
specifies two result columns (A and B).  
System Action: The SQL query is terminated.  
User Response: None.  
A subquery expression may not contain a reference to a column name that is  
contained in an outer query expression.  
Explanation: A subquery contains a reference to a column name in an outer query  
expression.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2932E  
ANR2933E  
The maximum nesting depth for subquery expressions has been exceeded.  
Explanation: Too many nested subqueries were specified.  
System Action: The SQL query is terminated.  
User Response: None.  
The WHERE clause must not contain an aggregate function.  
Explanation: The use of the aggregate functions COUNT, MAX, MIN, SUM,  
AVG, VARIANCE, or STDDEV in the WHERE clause is not allowed.  
System Action: The SQL query is terminated.  
User Response: None.  
420  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2934E  
The result data type of a CASE expression can not be determined; at least one  
non-null THEN or ELSE expression must be specified.  
Explanation: The result data type of a CASE expression can not be determined  
because all of the THEN expressions and the ELSE expression (if present) specifies  
the NULL key word.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2935E  
ANR2936E  
ANR2937E  
ANR2938E  
The date-time field field is not present in the expression ’expression’ (data type  
data type).  
Explanation: The specified date-time field (YEAR, MONTH, DAY, HOUR,  
MINUTE, or SECOND) is not contained in the data type of the expression.  
System Action: The SQL query is terminated.  
User Response: None.  
The SQL aggregate function function can not be nested within another  
aggregate function.  
Explanation: One of the aggregate functions COUNT, MAX, MIN, SUM, AVG,  
VARIANCE, or STDDEV was found nested within another aggregate expression.  
System Action: The SQL query is terminated.  
User Response: None.  
An SQL subquery expression can not be nested within an aggregate function.  
Explanation: An expression containing a subquery was found nested within one of  
the aggregate functions COUNT, MAX, MIN, SUM, AVG, VARIANCE, or  
STDDEV.  
System Action: The SQL query is terminated.  
User Response: None.  
The column ’column’ is not allowed in this context; it must either be named in  
the GROUP BY clause or be nested within an aggregate function.  
Explanation: A column reference was specified that is neither a column specified  
in a GROUP BY clause nor is a column nested in one of the aggregate functions  
COUNT, MAX, MIN, SUM, AVG, VARIANCE, or STDDEV. The use of the  
Tivoli Storage Manager Messages  
421  
Download from Www.Somanuals.com. All Manuals Search And Download.  
column reference is prohibited because either 1) the GROUP BY clause has been  
specified, 2) the HAVING clause has been specified, or 3) at least one aggregate  
function is present.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2939E  
The reference ’reference’ is an unknown SQL table name.  
Explanation: The specified table reference is not one of the base tables defined by  
the server’s database. The rows of the table SYSCAT.TABLES can be selected to  
obtain a list of all of the valid base tables.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2940E  
The reference ’reference’ is an unknown SQL column name.  
Explanation: The specified column reference is not one of the base table columns  
defined by the server’s database. The rows of the table SYSCAT.COLUMNS can be  
selected to obtain a list of all of the valid base table columns. If a two-part  
(compound) column reference such as X.Y is specified, then the correlation name X  
must be one of the active correlation names for the query.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2941E  
The column reference ’column reference’ matches more than one SQL column  
name.  
Explanation: The specified column reference is ambiguous because it matches the  
columns associated with multiple tables.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2942E  
The column reference ’column reference’ is not allowed in this context because it  
is part of an outer SQL query expression.  
Explanation: The specified column reference is not allowed because it names a  
columns of some outer query expression. Such references are not allowed when  
contained within the expressions of the HAVING and SELECT clauses.  
System Action: The SQL query is terminated.  
User Response: None.  
422  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2943E  
The column reference ’column reference’ is a duplicate of another SQL column  
name in the same list.  
Explanation: A duplicate column reference was specified within the same GROUP  
BY or ORDER BY list of columns.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2944E  
The reference ’reference’ is an unknown SQL scalar function name.  
Explanation: The specified function reference is not the name of a valid scalar  
function.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2945E  
Too few arguments are specified for SQL scalar function function.  
Explanation: Too few function arguments were specified. For example, the  
expression LEFT(x) is invalid because the LEFT function requires at least two  
arguments.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2946E  
Too many arguments are specified for SQL scalar function function.  
Explanation: Too many function arguments were specified. For example, the  
expression UPPER(x,y) is invalid because the UPPER function requires exactly one  
argument.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2947E  
Division by zero was detected for operator ’operator’.  
Explanation: An attempt to divide by the number zero was detected for the  
specified SQL operator. The most likely cause of the problem is that one of the  
values of a column is zero, and that column is used in the denominator of a division  
operation. To protect against this case the NULLIF function can be used. For  
example, instead of the expression 1/X, specify 1/NULLIF(X,0), which will set the  
expression to null whenever the value if X is zero.  
System Action: The SQL query is terminated.  
Tivoli Storage Manager Messages  
423  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2948E  
The value ’value’ can not be assigned or converted to SQL data type data type.  
Explanation: A value could not assigned or converted to a value in the specified  
SQL data type because either 1) the data type of the value can not be legally cast to  
the target data type (for example, data type TIME can not be converted to data type  
INTEGER); 2) the assignment of the value results in overflow in the target data  
type (for example, the decimal value 12345678.34 can not be assigned to data type  
DECIMAL(3,2) because the precision of the target type is exceeded); or 3) the  
syntax of a character string value is not appropriate for the target data type (for  
example, the string ’abc’ can not be converted to data type DATE).  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2949E  
Arithmetic overflow occurred for SQL operator ’operator’.  
Explanation: An arithmetic overflow occurred for the specified operator.  
Examples of this include: 1) the application of the unary negation operator to the  
smallest INTEGER value (-2147483648) causes overflow because the result can not  
be represented in 2’s complement; 2) the sum of the set of INTEGER column  
values applied to the SUM aggregate function can not be represented within the  
precision of INTEGER type.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2950E  
Arithmetic or date-time overflow occurred for SQL operator ’operator’ for  
values ’value’ (data type data type) and ’value’ (data type data type).  
Explanation: An arithmetic or date-time overflow occurred for the specified  
operator. The values that caused the overflow (and their SQL data types) are  
displayed.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2951E  
The value ’value’ (data type data type) is not a valid argument for operator  
operator’.  
Explanation: An invalid value was specified as an argument to an SQL operator.  
For example, the expression SQRT(-1) is not valid because the argument to the  
SQRT function is negative.  
System Action: The SQL query is terminated.  
424  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR2952E  
ANR2953E  
ANR2954E  
The value ’value’ (data type data type) is not a valid character string  
representation of an SQL date or a timestamp for operator ’operator’.  
Explanation: An invalid character string representation of a DATE or  
TIMESTAMP was specified. For example, the string ’abc’ is neither a valid date nor  
a timestamp.  
System Action: The SQL query is terminated.  
User Response: None.  
The value ’value’ (data type data type) is not a valid character string  
representation of an SQL time or a timestamp for operator ’operator’.  
Explanation: An invalid character string representation of a TIME or  
TIMESTAMP was specified. For example, the string ’g pm’ is neither a valid time  
nor a timestamp.  
System Action: The SQL query is terminated.  
User Response: None.  
An SQL subquery used in a scalar expression must yield a table that contains  
at most one row.  
Explanation: This error results when a subquery used in a scalar expression  
returns multiple rows, thereby making it ambiguous as to which value should be  
returned.  
System Action: The SQL query is terminated.  
User Response: Respecify the subquery (for example, using the WHERE clause)  
so that the subquery returns at most one row.  
ANR2955E  
The SQL character string expression ’expression’ must return a single  
character.  
Explanation: A single-character character string was expected for the ESCAPE  
clause of the LIKE operator, for the trim character of the TRIM operator, or for the  
pad character of the LEFT or RIGHT function. For example, the string ’Hello’ is  
invalid because it contains multiple characters.  
System Action: The SQL query is terminated.  
User Response: None.  
Tivoli Storage Manager Messages  
425  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR2956E  
Unable to access SQL base table ’table’.  
Explanation: An error occurred when attempting to read rows from one of the  
SQL base tables. This message is typically preceded by another error describing the  
condition.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2957E  
An error occurred inserting a row in an SQL temporary table. The server  
database size may need to be increased  
Explanation: An error occurred when attempting to insert a row into a temporary  
table being used for an SQL query. This message is typically preceded by another  
error describing the condition. In many cases this error can be resolved by  
increasing the size of the server database. Free space in the database is used to store  
temporary tables created during the execution of an SQL SELECT query.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2958E  
SQL temporary table storage has been exhausted.  
Explanation: The result of an SQL query could not be computed because  
insufficient temporary table storage space was available. Free space in the server  
database is used to store temporary tables created during the execution of an SQL  
SELECT query. In many cases the web admin client uses SQL commands to  
retrieve necessary data from the server. Complex SQL queries such as those  
containing the following conditions can cause temporary table space to be required:  
the ORDER BY clause, the GROUP BY clause, and, the DISTINCT operator. In  
most cases this error can be resolved by increasing the size of the server database.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2959E  
SQL temporary table row is too wide.  
Explanation: A row could not be inserted into an SQL temporary table because  
the row is too wide. This can occur if 1) there are too many columns in the row  
being inserted, or 2) the sum of the lengths of the columns in the row is too wide.  
Temporary tables are used when 1) the ORDER BY clause is specified; 2) the  
GROUP BY clause is specified; or 3) the DISTINCT operator is specified.  
System Action: The SQL query is terminated.  
426  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reduce the number of columns specified in the ORDER BY  
and/or GROUP BY clauses.  
ANR2960E  
Unexpected SQL enumerated type name token - ’token’.  
Explanation: A syntax error occurred because an SQL enumerated type name was  
found that can not legally be used at the specified position within the SQL  
statement. A list of all of the enumerated types declared by the server can be found  
in the SQL catalog table SYSCAT.ENUMTYPES.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2961E  
Invalid SQL enumerated type name - ’name’.  
Explanation: A syntax error occurred because an SQL enumerated type name was  
expected, but the specified name is not one of the declared enumerated types. For  
example, the literal expression XXX::YYYY is illegal because XXX is not a valid  
enumerated type name. A list of all of the enumerated types declared by the server  
can be found in the SQL catalog table SYSCAT.ENUMTYPES.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2962E  
Unable to resolve SQL enumerated type for value ’value’.  
Explanation: A syntax error occurred because an unqualified SQL enumerated  
value name was specified, but, because that value name is a member of more than  
one enumerated type, its type could not be resolved. For example, the enumerated  
value name YES belongs to more than one enumerated type, and so the result type  
of the expression YES = YES can not be resolved. A list of all of the enumerated  
types declared by the server can be found in the SQL catalog table  
SYSCAT.ENUMTYPES.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2963W  
This SQL query may produce a very large result table, or may require a  
significant amount of time to compute.  
Explanation: An SQL query has been posed that could potentially cause a very  
large number of rows to be returned and displayed, or may involve a large amount  
of processing time before the first result table row can be generated.  
System Action: The administrator is asked whether to continue.  
Tivoli Storage Manager Messages  
427  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Enter 'Y' to continue with SQL query processing or 'N' to  
terminate the query.  
ANR2964E  
The reference ’reference’ is not a column of the SQL result table.  
Explanation: The ORDER BY clause specified a column that is not part of the  
result table for the SQL query. Only those columns named in the select list are part  
of the result table.  
System Action: The SQL query is terminated.  
User Response: None.  
ANR2965E  
An SQL temporary table cannot be built. required columns columns are needed.  
maximum columns is the maximum.  
Explanation: A temporary table required columns wide is needed to complete  
processing for an SQL query. The maximum degree of an SQL table is maximum  
columns. The table will not be created.  
System Action: The SQL query is terminated.  
User Response: If the ORDER BY and/or GROUP BY clauses were specified,  
reduce the number of columns needed for the result table.  
ANR2966E  
command/process: Database temporary table storage has been exhausted.  
Explanation: The named command or operation could not be completed because  
insufficient temporary table storage space was available. Free space in the server  
database is used to store temporary tables created during the execution of the named  
command or process.  
System Action: The named command or process is terminated.  
User Response: Extend the server datbase (after adding database volumes if  
necessary) and re-run the commmand or process.  
ANR3000E  
command: Command can only be issued on a configuration manager.  
Explanation: The command can only be issued on a server that is a configuration  
manager.  
System Action: Server operation continues. The command is not processed.  
User Response: Issue this command from a configuration manager.  
428  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3001E  
ANR3002E  
command: Command can only be issued on a managed server.  
Explanation: The command can only be issued on a managed server.  
System Action: Server operation continues. The command is not processed.  
User Response: Issue this command from a managed server.  
command: Profile name exceeds maximum length characters.  
Explanation: The profile name specified in the command is longer than the  
maximum length allowed.  
System Action: Server operation continues. The command is not processed.  
User Response: Select a profile name that does not exceed the maximum length.  
ANR3003E  
command: Profile description exceeds maximum length characters.  
Explanation: The profile description specified in the command is longer than the  
maximum length allowed.  
System Action: Server operation continues. The command is not processed.  
User Response: Select a description that does not exceed the maximum length.  
ANR3004E  
command: The configuration manager name exceeds maximum length characters.  
Explanation: The configuration manager name specified in the command is longer  
than the maximum length allowed.  
System Action: Server operation continues. The command is not processed.  
User Response: Select a configuration manager name that does not exceed the  
maximum length.  
ANR3005E  
command: The server name exceeds maximum length characters.  
Explanation: The configuration manager name specified in the command is longer  
than the maximum length allowed.  
System Action: Server operation continues. The command is not processed.  
User Response: Select a configuration manager name that does not exceed the  
maximum length.  
Tivoli Storage Manager Messages  
429  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3006E  
command: The configuration refresh interval value must be between minimum  
value and maximum value.  
Explanation: The specified command has been issued with an invalid refresh  
interval.  
System Action: Server operation continues. The command is not processed.  
User Response: Issue the command and specify a valid refresh interval value.  
ANR3007E  
command: The option option must be specified.  
Explanation: When the command is issued on a a server that is neither a  
configuration manager nor a managed server, the specified option must be supplied.  
System Action: Server operation continues. The command is not processed.  
User Response: Reissue the command with the specified option.  
ANR3010W  
This command will delete an object that is associated with one or more profiles  
on a configuration manager. Subsequent configuration refresh processing will  
delete the object on managed servers that subscribe to a profile with which the  
object is associated.  
Explanation: A command has been entered that will delete an object from a  
configuration manager. Since this object is associated with one or more profiles on a  
configuration manager, configuration refresh processing will delete this object on  
subscribing managed servers.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the command, enter 'Y' to continue or 'N' to stop the  
process.  
ANR3011E  
command: Subscription for profile profile name was not deleted because one or  
more objects could not be discarded.  
Explanation: This message was issued because one or more objects could not be  
discarded by the indicated command. A previous message gives an explanation for  
each object that could not be discarded.  
System Action: The system may discard some of the managed objects that are  
associated with profile profile name The subscription itself is not deleted.  
User Response: Examine previous messages to determine the action that must be  
taken before remaining objects can be discarded. Alternatively, you can delete the  
subscription without using the DISCARDOBJECTS=YES option.  
430  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3012I  
command: Configuration manager state set to state.  
Explanation: The command has successfully set the configuration manager state.  
System Action: The command succeeded.  
User Response: None.  
ANR3013W  
command: Configuration manager state already set to state.  
Explanation: The specified state is already in force on the server.  
System Action: Server operation continues. The command is not processed.  
User Response: This server is already set to the specified state. If the state should  
be set differently, reissue the command specifying the new state value.  
ANR3014E  
command: One or more subscriptions still exist.  
Explanation: A configuration manager state cannot be set to OFF is one or more  
subscription still exist. The server still has a record of one or more subscriptions to  
its profiles.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SUBSCRIBERS command to determine which  
subscriptions still exist. The DELETE SUBSCRIBER command can be used to  
remove the record of these subscriptions. You may instead want to delete the actual  
subscription(s) on the managed server(s). When there are no more subscriptions  
recorded on the configuration manager, you must then delete all the profiles. Once  
the profiles have been deleted, you can reissue the command.  
ANR3015E  
command: One or more profiles still exist.  
Explanation: A configuration manager state cannot be set to OFF is one or more  
profiles still exist.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFILE command to determine which profiles  
still exist on the configuration manager then use the DELETE PROFILE command.  
After all the profiles have been deleted, reissue the command.  
ANR3016I  
command: Configuration refresh interval set to interval.  
Explanation: The command has successfully set the configuration refresh interval  
to the specified value. Automatic configuration refresh processing will immediatly  
be attempted and then will again be performed after the specified number of  
minutes of elapsed.  
Tivoli Storage Manager Messages  
431  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command succeeded.  
User Response: None.  
ANR3017I  
ANR3018E  
ANR3019I  
ANR3020E  
command: Profile profile name defined.  
Explanation: The command has successfully define a profile.  
System Action: The command succeeded.  
User Response: None.  
command: Profile profile name already exists.  
Explanation: The profile specified already exists on the configuration manager.  
System Action: Server operation continues. The command is not processed.  
User Response: Decide on another profile name and reissue the command.  
command: Profile profile name updated.  
Explanation: The command has successfully updated a profile.  
System Action: The command succeeded.  
User Response: None.  
command: Profile profile name not found.  
Explanation: The profile specified could not be found.  
System Action: Server operation continues. The command is not processed.  
User Response: Check to see if the profile name was specified correctly on the  
command. Use the QUERY PROFILE command to check to see if the profile exists  
on the configuration manager. Reissue the command with the correct profile name.  
ANR3021I  
command: Profile profile name copied to profile profile name.  
Explanation: The command has successfully copied the first profile to the newly  
created second profile. All the profile associations were also copied.  
System Action: The command succeeded.  
User Response: None.  
432  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3022E  
command: The profile lock timeout interval value must be between minimum  
value and maximum value.  
Explanation: The specified command has been issued with an invalid lock timeout  
interval.  
System Action: Server operation continues. The command is not processed.  
User Response: Issue the command and specify a valid lock timeout interval  
value.  
ANR3023I  
command: Profile profile name locked.  
Explanation: The command has successfully locked the profile. No configuration  
information can be propogated to the subscribers of the profile until it is unlocked.  
System Action: The command succeeded.  
User Response: None.  
ANR3024W  
command: Profile profile already locked with timeout interval greater than  
interval.  
Explanation: An attempt was made to lock the specified profile. The profile is  
already locked with a timeout interval greater than the value specifed.  
System Action: The profile remains locked with the original timeout interval.  
User Response: If you want to lower the timeout interval, unlock the profile and  
then lock the profile again specifying the lower value.  
ANR3025I  
command: Profile profile name unlocked.  
Explanation: The command has successfully unlocked the profile. Configuration  
information can now be propogated to the subscribers of the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3026I  
command: Profile profile name deleted.  
Explanation: The command has successfully deleted the profile from the  
configuration manager.  
System Action: The command succeeded.  
User Response: None.  
Tivoli Storage Manager Messages  
433  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3027E  
command: One or more subscriptions still exist to profile profile name.  
Explanation: An attempt was made to delete a profile that still has subscriptions  
defined on one or more managed servers. The configuration manager still has a  
record of one or more subscriptions to the profiles.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SUBSCRIBERS command to determine which  
subscriptions still exist. Use the DELETE SUBSCRIPTION command on the  
managed server(s) to delete the subscriptions, and then reissue the DELETE  
PROFILE command on the configuration manager. Alternatively, the FORCE=YES  
option can be used on the DELETE PROFILE command to delete the profile even  
if there are subscriptions to the profile. In this case, messages will be issued when  
the managed server requests updates for that profile, informing the managed server  
that the profile has been deleted.  
ANR3028E  
ANR3029E  
ANR3030I  
ANR3031W  
command: Profile profile name is locked.  
Explanation: The specifed command cannot be performed on a locked profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Unlock the profile using the UNLOCK PROFILE command and  
then reissue the command.  
command: Profile name not specified.  
Explanation: A profile name must be specifed on this command using the  
PROFILE= parameter.  
System Action: Server operation continues. The command is not processed.  
User Response: Reissue the command and specify a profile name.  
command: Subscription defined for profile profile name.  
Explanation: The command has successfully defined a subscription to the  
specified profile. A refresh of the configuration information has been initiated.  
System Action: The command succeeded.  
User Response: None.  
command: Subscription for profile profile name already exists.  
Explanation: A subscription already exists for the specified profile.  
System Action: Server operation continues. The command is not processed.  
434  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check to make sure you specified the correction profile name, and  
reissue the command if needed.  
ANR3032E  
command: Server name not specified.  
Explanation: A server name must be specifed on this command using the  
SERVER= parameter. This identifies the configuration manager.  
System Action: Server operation continues. The command is not processed.  
User Response: Reissue the command and specify a server name.  
ANR3033E  
command: Server server is not the managed server’s configuration manager.  
Explanation: A server name was specified on the command which does not match  
the current configuration manager. A managed server may only have one  
configuration manager.  
System Action: Server operation continues. The command is not processed.  
User Response: Reissue the command and leave off the server parameter. It will  
default to use the current configuration manager. A QUERY SUBSCRIPTION will  
display the configuration manager currently in use.  
ANR3034E  
command: Server server cannot be used as this server’s configuration manager.  
Explanation: A server name was specified on the command which cannot be used  
as a configuration manager.  
System Action: Server operation continues. The command is not processed.  
User Response: Find out the currect name for the configuration manager and then  
reissue the command.  
ANR3035I  
command: Subscriber subscriber name deleted.  
Explanation: The command has successfully deleted a subscriber from the record  
kept in the configuration manager. If the subscriber (managed server) still has a  
subscription to a valid profile, the record of the subscription will reappear when it  
performs its next configuration refresh.  
System Action: The command succeeded.  
User Response: None.  
ANR3036E  
command: Subscriber subscriber name not found.  
Explanation: The specified subscriber name was not found in the configuration  
manager’s records as being a valid subscriber of any profiles.  
Tivoli Storage Manager Messages  
435  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. The command is not processed.  
User Response: Check to see that the subscriber (managed server) name is  
correction. If you think the name is correct, perhaps the managed server has not yet  
successfully contacted the configuration manager to inform it that the subscription  
exists.  
ANR3037I  
command: Subscription deleted for profile profile name.  
Explanation: The command has successfully deleted a subscription for the  
specified profile. A refresh of the configuration information has been initiated.  
System Action: The command succeeded.  
User Response: None.  
ANR3038E  
command: Subscription for profile profile name not found.  
Explanation: A subscription was not found for the specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Check to see that the profile name was specified correctly. Issue  
the QUERY SUBSCRIPTION command to check to see which profiles have  
subscriptions. Reissue the command with the correct profile name.  
ANR3039E  
command: No matching administrators found in configuration.  
Explanation: No administrator definitions were found on the configuration  
manager that match the admin(s) specified on the DEFINE PROFASSOCIATION  
command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY ADMIN command to check which administrators  
that are defined on the server and then reissue to DEFINE PROFASSOCIATION  
command.  
ANR3040I  
command: All administrators associated with profile profilename.  
Explanation: The command has successfully associated all the administrators with  
the specified profile. All administrator definitions will be automatically propogated  
to managed servers which subscribe to the profile. If an administrator is added to  
the configuration manager in the future, its definition will also be automatically  
propogated to the managed servers.  
System Action: The command succeeded.  
User Response: None.  
436  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3041I  
command: Administrator admin associated with profile profilename.  
Explanation: The command has successfully associated the administrator with the  
specified profile. The administrator definition will be automatically propogated to  
managed servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3042W  
command: No additional administrators associated with profile profilename.  
Explanation: No additional administrator were associated with the profile. The  
administrator(s) specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY ADMIN command to check which administrators  
are defined on the server and then reissue to DEFINE PROFASSOCIATION  
command. The QUERY PROFASSOCIATION FORMAT=DETAILED can be used  
to see which administrators are already associated with the profile.  
ANR3043E  
command: No matching domains found in configuration.  
Explanation: No domain definitions were found on the configuration manager that  
match the domain(s) specified on the DEFINE PROFASSOCIATION command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY DOMAIN command to check which domains  
that are defined on the server and then reissue to DEFINE PROFASSOCIATION  
command.  
ANR3044I  
command: All domains associated with profile profilename.  
Explanation: The command has successfully associated all the domains with the  
specified profile. All domain definitions will be automatically propogated to  
managed servers which subscribe to the profile. If a domain is added to the  
configuration manager in the future, its definition will also be automatically  
propogated to the managed servers.  
System Action: The command succeeded.  
User Response: None.  
Tivoli Storage Manager Messages  
437  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3045I  
command: Domain domain associated with profile profilename.  
Explanation: The command has successfully associated the domain with the  
specified profile. The domain definition will be automatically propogated to  
managed servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3046W  
command: No additional domains associated with profile profilename.  
Explanation: No additional domains were associated with the profile. The  
domain(s) specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY DOMAIN command to check which domains are  
defined on the server and then reissue to DEFINE PROFASSOCIATION command.  
The QUERY PROFASSOCIATION FORMAT=DETAILED can be used to see  
which domains are already associated with the profile.  
ANR3047E  
command: No matching admin schedules found in configuration.  
Explanation: No admin schedule definitions were found on the configuration  
manager that match the admin schedule(s) specified on the DEFINE  
PROFASSOCIATION command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SCHEDULE TYPE=ADMIN command to check  
which admin schedules are defined on the server and then reissue to DEFINE  
PROFASSOCIATION command.  
ANR3048I  
command: All admin schedules associated with profile profilename.  
Explanation: The command has successfully associated all the admin schedules  
with the specified profile. All admin schedule definitions will be automatically  
propogated to managed servers which subscribe to the profile. If an admin schedule  
is added to the configuration manager in the future, its definition will also be  
automatically propogated to the managed servers.  
System Action: The command succeeded.  
User Response: None.  
438  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3049I  
command: Admin Schedule admin schedule associated with profile profilename.  
Explanation: The command has successfully associated the admin schedule with  
the specified profile. The admin schedule definition will be automatically  
propogated to managed servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3050W  
command: No additional admin scheduless associated with profile profilename.  
Explanation: No additional admin schedules were associated with the profile. The  
admin schedule(s) specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SCHEDULE TYPE=ADMIN command to check  
which admin schedules are defined on the server and then reissue to DEFINE  
PROFASSOCIATION command. The QUERY PROFASSOCIATION  
FORMAT=DETAILED can be used to see which admin schedules are already  
associated with the profile.  
ANR3051E  
command: No matching scripts found in configuration.  
Explanation: No script definitions were found on the configuration manager that  
match the script(s) specified on the DEFINE PROFASSOCIATION command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SCRIPT command to check which scripts that  
are defined on the server and then reissue to DEFINE PROFASSOCIATION  
command.  
ANR3052I  
command: All scripts associated with profile profilename.  
Explanation: The command has successfully associated all the scripts with the  
specified profile. All script definitions will be automatically propogated to managed  
servers which subscribe to the profile. If a script is added to the configuration  
manager in the future, its definition will also be automatically propogated to the  
managed servers.  
System Action: The command succeeded.  
User Response: None.  
Tivoli Storage Manager Messages  
439  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3053I  
command: Script script associated with profile profilename.  
Explanation: The command has successfully associated the script with the  
specified profile. The script definition will be automatically propogated to managed  
servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3054W  
command: No additional scripts associated with profile profilename.  
Explanation: No additional scripts were associated with the profile. The script(s)  
specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SCRIPT command to check which scripts are  
defined on the server and then reissue to DEFINE PROFASSOCIATION command.  
The QUERY PROFASSOCIATION FORMAT=DETAILED can be used to see  
which scripts are already associated with the profile.  
ANR3055E  
command: No matching client option sets found in configuration.  
Explanation: No client option set definitions were found on the configuration  
manager that match the client option set(s) specified on the DEFINE  
PROFASSOCIATION command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY CLOPTSET command to check which client  
option sets that are defined on the server and then reissue to DEFINE  
PROFASSOCIATION command.  
ANR3056I  
command: All client option sets associated with profile profilename.  
Explanation: The command has successfully associated all the client option sets  
with the specified profile. All client option set definitions will be automatically  
propogated to managed servers which subscribe to the profile. If a client option set  
is added to the configuration manager in the future, its definition will also be  
automatically propogated to the managed servers.  
System Action: The command succeeded.  
User Response: None.  
440  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3057I  
command: Client option set client option set associated with profile profilename.  
Explanation: The command has successfully associated the client option set with  
the specified profile. The client option set definition will be automatically  
propogated to managed servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3058W  
command: No additional client option sets associated with profile profilename.  
Explanation: No additional client option sets were associated with the profile. The  
client option set(s) specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY CLOPTSET command to check which client  
option sets are defined on the server and then reissue to DEFINE  
PROFASSOCIATION command. The QUERY PROFASSOCIATION  
FORMAT=DETAILED can be used to see which client option sets are already  
associated with the profile.  
ANR3059E  
command: No matching servers found in configuration.  
Explanation: No server definitions were found on the configuration manager that  
match the server(s) specified on the DEFINE PROFASSOCIATION command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SERVER command to check which servers that  
are defined on the server and then reissue to DEFINE PROFASSOCIATION  
command.  
ANR3060I  
command: All servers associated with profile profilename.  
Explanation: The command has successfully associated all the servers with the  
specified profile. All server definitions will be automatically propogated to managed  
servers which subscribe to the profile. If a server is added to the configuration  
manager in the future, its definition will also be automatically propogated to the  
managed servers.  
System Action: The command succeeded.  
User Response: None.  
Tivoli Storage Manager Messages  
441  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3061I  
command: Server server associated with profile profilename.  
Explanation: The command has successfully associated the server with the  
specified profile. The server definition will be automatically propogated to managed  
servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3062W  
command: No additional servers associated with profile profilename.  
Explanation: No additional servers were associated with the profile. The server(s)  
specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SERVER command to check which servers are  
defined on the server and then reissue to DEFINE PROFASSOCIATION command.  
The QUERY PROFASSOCIATION FORMAT=DETAILED can be used to see  
which servers are already associated with the profile.  
ANR3063E  
command: No matching server groups found in configuration.  
Explanation: No server group definitions were found on the configuration  
manager that match the server group(s) specified on the DEFINE  
PROFASSOCIATION command.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SERVERGROUP command to check which  
server groups that are defined on the server and then reissue to DEFINE  
PROFASSOCIATION command.  
ANR3064I  
command: All server groups associated with profile profilename.  
Explanation: The command has successfully associated all the server groups with  
the specified profile. All server group definitions will be automatically propogated  
to managed servers which subscribe to the profile. If a server group is added to the  
configuration manager in the future, its definition will also be automatically  
propogated to the managed servers.  
System Action: The command succeeded.  
User Response: None.  
442  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3065I  
command: Server group server group associated with profile profilename.  
Explanation: The command has successfully associated the server group with the  
specified profile. The server group definition will be automatically propogated to  
managed servers which subscribe to the profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3066W  
command: No additional server groups associated with profile profilename.  
Explanation: No additional server groups were associated with the profile. The  
server group(s) specified are already associated with the profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY SERVERGROUP command to check which  
server groups are defined on the server and then reissue to DEFINE  
PROFASSOCIATION command. The QUERY PROFASSOCIATION  
FORMAT=DETAILED can be used to see which server groups are already  
associated with the profile.  
ANR3067E  
command: No matching administrators associated with profile profile.  
Explanation: No matching administrator definitions are associated with the  
specified specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
administrators are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
ANR3068I  
command: All administrator associations deleted from profile profilename.  
Explanation: The command has successfully deleted all administrators associations  
from the specified profile. This will automatically delete these administrators from  
the managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3069I  
command: Administrator association admin deleted from profile profilename.  
Explanation: The command has successfully deleted an administrator association  
from the specified profile. This will automatically delete this administrator from the  
managed servers that are subscribed to this profile.  
Tivoli Storage Manager Messages  
443  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command succeeded.  
User Response: None.  
ANR3070E  
command: No matching domains associated with profile profile.  
Explanation: No matching domain definitions are associated with the specified  
specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
domains are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
ANR3071I  
ANR3072I  
ANR3073E  
command: All domain associations deleted from profile profilename.  
Explanation: The command has successfully deleted all domains associations from  
the specified profile. This will automatically delete these domains from the managed  
servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
command: Domain association domain deleted from profile profilename.  
Explanation: The command has successfully deleted a domain association from  
the specified profile. This will automatically delete this domain from the managed  
servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
command: No matching admin schedules associated with profile profile.  
Explanation: No matching admin schedule definitions are associated with the  
specified specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
admin schedules are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
444  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3074I  
command: All admin schedule associations deleted from profile profilename.  
Explanation: The command has successfully deleted all admin schedules  
associations from the specified profile. This will automatically delete these admin  
schedules from the managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3075I  
command: Admin schedule association admin schedule deleted from profile  
profilename.  
Explanation: The command has successfully deleted an admin schedule  
association from the specified profile. This will automatically delete this admin  
schedule from the managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3076E  
command: No matching scripts associated with profile profile.  
Explanation: No matching script definitions are associated with the specified  
specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
scripts are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
ANR3077I  
command: All script associations deleted from profile profilename.  
Explanation: The command has successfully deleted all scripts associations from  
the specified profile. This will automatically delete these scripts from the managed  
servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3078I  
command: Script association script deleted from profile profilename.  
Explanation: The command has successfully deleted a script association from the  
specified profile. This will automatically delete this script from the managed servers  
that are subscribed to this profile.  
System Action: The command succeeded.  
Tivoli Storage Manager Messages  
445  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR3079E  
command: No matching client option sets associated with profile profile.  
Explanation: No matching clent option set definitions are associated with the  
specified specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
client option sets are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
ANR3080I  
command: All client option set associations deleted from profile profilename.  
Explanation: The command has successfully deleted all client option sets  
associations from the specified profile. This will automatically delete these client  
option sets from the managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3081I  
command: Client option set association client option set deleted from profile  
profilename.  
Explanation: The command has successfully deleted a client option set association  
from the specified profile. This will automatically delete this client option set from  
the managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3082E  
command: No matching servers associated with profile profile.  
Explanation: No matching server definitions are associated with the specified  
specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
servers are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
446  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3083I  
ANR3084I  
ANR3085E  
command: All server associations deleted from profile profilename.  
Explanation: The command has successfully deleted all servers associations from  
the specified profile. This will automatically delete these servers from the managed  
servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
command: Server association server deleted from profile profilename.  
Explanation: The command has successfully deleted a server association from the  
specified profile. This will automatically delete this server definition from the  
managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
command: No matching server groups associated with profile profile.  
Explanation: No matching server group definitions are associated with the  
specified specified profile.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFASSOCIATION command to check which  
server groups are associated with the profile and then reissue to DELETE  
PROFASSOCIATION command.  
ANR3086I  
command: All server group associations deleted from profile profilename.  
Explanation: The command has successfully deleted all server groups associations  
from the specified profile. This will automatically delete these server groups from  
the managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
User Response: None.  
ANR3087I  
command: Server group association server group deleted from profile  
profilename.  
Explanation: The command has successfully deleted a server group association  
from the specified profile. This will automatically delete this server group from the  
managed servers that are subscribed to this profile.  
System Action: The command succeeded.  
Tivoli Storage Manager Messages  
447  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR3088W  
This command will cause the deletion of objects on any managed server  
subscribed to profile profile name.  
Explanation: A DELETE PROFASSOCIATION command option has been  
entered. This action will not only delete the association from the profile, but it will  
also result in the deletion of managed object(s) on any managed server subscribing  
to this profile. The deletion of these objects will occurr during the next  
configuration refresh for that managed server.  
System Action: The system asks whether you wish to continue with the command.  
User Response: To process the DELETE PROFASSOCATION command, enter 'Y'  
to continue or 'N' to stop the command.  
ANR3089E  
command: Command failed - Server-to-server communication error with server  
server name.  
Explanation: The specified command failed while attempting to communicate with  
the indicated server.  
System Action: Server operation continues. The command is not processed.  
User Response: Verify that the indicated server name is correctly defined. Try  
reissuing the command. Use the server PING command to see if the other server is  
up. If the problem persists, consult with your network administrator.  
ANR3090E  
command: Server server name is not a configuration manager.  
Explanation: The specified command failed because it tried to contact the  
specified server, and discovered that the server is not a configuration manager.  
System Action: Server operation continues. The command is not processed.  
User Response: Reissue the command and specify a correct configuration manager  
name.  
ANR3091E  
command: Profile list not specified.  
Explanation: The specified command failed because you did not specify a profile  
list on the command.  
System Action: Server operation continues. The command is not processed.  
User Response: Reissue the command specifying a profile list.  
448  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3092I  
command: Subscriber notification processing has begun.  
Explanation: A NOTIFY SUBSCRIBER process has begun. The managed  
server(s) are being contacted, asking them to immediately perform a configuration  
refresh.  
System Action: Server operation continues. The command succeeded.  
User Response: None.  
ANR3093I  
command: No matching profiles or subscriptions were found.  
Explanation: No subscriptions were found for the profiles specified. Either the  
profiles do not exist, or there are no subscriptions to the profiles.  
System Action: Server operation continues. The command is not processed.  
User Response: Use the QUERY PROFILE and QUERY SUBSCRIBER command  
to determine which profiles exist and which profiles have subscribers. Reissue the  
command specifying the correct profile name(s).  
ANR3150E  
Configuration refresh failed with configuration manager server name. Will retry  
in minutes minutes.  
Explanation: While receiving configuration information from the specified  
configuration manager, processing failed because of a communications error.  
System Action: Server operation continues. The configuration refresh process was  
stopped and will be automatically retried.  
User Response: Perhaps the configuration manager is not active. If the problem  
continues, contact the administrator for the configuration manager, or contact a  
network administrator. The refresh will automatically retry several times and then  
give up until the configuration refresh interval is reached again.  
ANR3151E  
Configuration refresh failed with configuration manager server name.  
Explanation: While receiving configuration information from the specified  
configuration manager, processing failed.  
System Action: Server operation continues. The configuration refresh process was  
stopped.  
User Response: Examine the activity log for other messages that may explain why  
the configuration refresh failed. The refresh will attempted again when the  
configuration refresh interval is reached.  
Tivoli Storage Manager Messages  
449  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3152I  
Configuration refresh started with configuration manager server name.  
Explanation: Configuration refresh processing has started. A server-to-server  
session was opened to receive configuration information from the configuration  
manager. Updates will be sent for objects associated with any subscribed-to profiles.  
System Action: Refresh processing continues.  
User Response: None.  
ANR3153I  
Configuration refresh ended successfully with configuration manager server  
name.  
Explanation: Configuration refresh processing ended successfully. All updates  
have been made to managed objects associated with any subscribed-to profiles.  
System Action: Server processing continues. The next automatic refresh will start  
when the configuration refresh interval is reached.  
User Response: None.  
ANR3154E  
Communication error on notify to managed server server name. Will retry in  
minutes minutes.  
Explanation: While attempting a notify subscriber request to the specified  
managed server, a communications error was detected.  
System Action: Server operation continues. The notify subscriber request was  
stopped and will be automatically retried.  
User Response: Perhaps the managed server is not active. If the problem  
continues, contact the administrator for the managed server, or contact a network  
administrator. The notify subscriber request will automatically retry several times  
and then give up.  
ANR3155E  
ANR3156E  
Error attempting notify subscribers request to managed server server.  
System Action: Server operation continues. The notify subscriber request failed.  
User Response: Examine the activity log for other messages that may explain why  
the notify subscriber request failed.  
Configuration refresh failed for managed server server name.  
Explanation: While sending configuration information to the specified managed  
server, processing failed.  
System Action: Server operation continues. The configuration refresh process  
ended.  
450  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the activity log of both the managed server and the  
configuration manager for other messages that may explain why the configuration  
refresh failed. The refresh will attempted again by the managed server when its  
configuration refresh interval is reached.  
ANR3157I  
Configuration refresh started for managed server server name.  
Explanation: Configuration refresh processing has started. A server-to-server  
session was opened by the managed server to receive configuration information  
from the configuration manager. Updates will be sent for objects associated with  
any subscribed-to profiles.  
System Action: Refresh processing continues.  
User Response: None.  
ANR3158I  
Configuration refresh ended successfully for managed server server name.  
Explanation: Configuration refresh processing ended successfully. All updates  
have been made to managed objects associated with any subscribed-to profiles on  
the managed server.  
System Action: Server processing continues.  
User Response: None.  
ANR3159E  
Managed server server name has newer version for profile profile name.  
Explanation: While sending configuration information to the specified managed  
server, it has been detected that the managed server has a newer version of  
configuration information for the specified profile than does the configuration  
manager. This condition can happen if the configuration manager’s database has  
been restored to an earlier point in time. Another possibility is that the profile was  
deleted on the configuration manager and a new profile by the same name was  
created.  
System Action: Server operation continues. No configuration information for this  
profile will be sent to the managed server until this condition is corrected.  
User Response: Before correcting the situation, you may want to use QUERY  
PROFILE to examine the profile associations defined on both the configuration  
manager and the managed server. To correct the situation, on the managed server  
delete the subscription to the profile and define the subscription again. This will  
cause the managed server to be refreshed at the configuration manager’s current  
level.  
Tivoli Storage Manager Messages  
451  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3160E  
Unable to receive confirmation of refresh from managed server server name.  
Explanation: While sending configuration information to the specified managed  
server, a communication error occurred when trying to receive confirmation from  
the managed server that information was processed successfully.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Determine if communication can be established with the managed  
server by using the server PING command. Use the NOTIFY SUBSCRIBERS  
command to force the configuration refresh to retry.  
ANR3161E  
Premature end of configuration refresh for managed server server server name.  
Explanation: While sending configuration information to the specified managed  
server, processing ended prematurely because of on error.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Examine the activity log on the managed server for any error  
messages that might explain why the refresh failed. Use the NOTIFY  
SUBSCRIBERS command on the configuration manager to force the configuration  
refresh to retry.  
ANR3162E  
Managed server server name aborted configuration refresh processing due to a  
low memory condition.  
Explanation: While sending configuration information to the specified managed  
server, processing ended prematurely because of a low memory condition on the  
managed server.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Make more memory available to the managed server.  
ANR3163E  
Managed server server name aborted configuration refresh processing due to an  
internal error.  
Explanation: While sending configuration information to the specified managed  
server, processing ended prematurely because of an internal error on the managed  
server.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
452  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the activity log of the managed server for messages that  
explain the cause of the internal error.  
ANR3164E  
Managed server server name aborted configuration refresh processing due to a  
lock conflict.  
Explanation: While sending configuration information to the specified managed  
server, processing ended prematurely because of a lock conflict on the managed  
server.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Use the NOTIFY SUBSCRIBERS command to retry the  
configuration refresh. If this problem persists, contact your service representative.  
ANR3165E  
Managed server server name aborted configuration refresh processing due to a  
protocol error.  
Explanation: While sending configuration information to the specified managed  
server, processing ended prematurely because of a protocol error detected on the  
managed server.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Use the NOTIFY SUBSCRIBERS command to retry the  
configuration refresh. If this problem persists, contact your service representative.  
ANR3166E  
Unable to receive configuration refresh information from server server name.  
Explanation: While receiving configuration information from the specified  
configuration manager, processing ended prematurely because of a communications  
error.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Use the server PING command to see if the configuration  
manager can be reached. If the problem persists, contact your network administrator.  
ANR3167E  
Configuration manager server name aborted configuration refresh processing  
due to a low memory condition.  
Explanation: While receiving configuration information from the specified  
configuration manager, processing ended prematurely because of a low memory  
condition on the configuration manager.  
Tivoli Storage Manager Messages  
453  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Notify the administrator of the configuration manager.  
ANR3168E  
Configuration manager server name aborted configuration refresh processing  
due to an internal error.  
Explanation: While receiving configuration information from the specified  
configuration manager, processing ended prematurely because of an internal error on  
the configuration manager.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Examine the activity log of the configuration manager for  
messages that explain the cause of the internal error.  
ANR3169E  
Configuration manager server name aborted configuration refresh processing  
due to a lock conflict.  
Explanation: While receiving configuration information from the specified  
managed server, processing ended prematurely because of a lock conflict on the  
configuration manager.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Retry the configuration refresh by issuing the SET  
CONFIGREFRESH command (using the current refresh interval value). If this  
problem persists, contact your service representative.  
ANR3170E  
Configuration manager server name aborted configuration refresh processing  
due to a protocol error.  
Explanation: While receiving configuration information from the specified  
configuration manager, processing ended prematurely because of a protocol error  
detected on the configuration manager.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Retry the configuration refresh by issuing the SET  
CONFIGREFRESH command (using the current refresh interval value). If this  
problem persists, contact your service representative.  
454  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3171E  
Configuration refresh with configuration manager server name had to skip  
processing for one or more objects.  
Explanation: While receiving configuration information from the specified  
configuration manager, it became necessary to skip the creation or deletion of one  
or more objects.  
System Action: Server operation continues. Configuration refresh processing  
ended.  
User Response: Examine the managed server’s activity log for earlier messages  
that identfy the object, and take the actions identified in those messages.  
Configuration refresh processing will not complete successfully until the problem is  
clear up.  
ANR3172W  
Subscription exists for deleted profile profile name.  
Explanation: While receiving configuration information from the configuration  
manager, it has been detected that the managed server has a subscription to an  
profile that no longer exists on the configuration manager. This condition can exist  
because the profile was deleted with FORCE=YES on the configuration manager.  
This out-of-synch condition can also occur because one of the server’s database was  
regressed because of a restore db.  
System Action: Server operation continues.  
User Response: The DELETE SUBSCRIPTION command is used to correct this  
situation. You need to decide if you want the managed objects to remain on the  
server. If you want them to be deleted, specify DISCARD=YES. If you want the  
objects to remain on the managed server as local objects, specify DISCARD=NO.  
ANR3173E  
Server has newer version for profile profile name than the configuration  
manager server name.  
Explanation: While receiving configuration information from the configuration  
manager, it has been detected that the managed server has a newer version of  
configuration information for the specified profile than does the configuration  
manager. This condition can happen if the configuration manager’s database has  
been restored to an earlier point in time. Another possibility is that the profile was  
deleted on the configuration manager with FORCE=YES and a new profile by the  
same name was created.  
System Action: Server operation continues. No configuration information for this  
profile will be sent to the managed server until this condition is corrected.  
User Response: Before correcting the situation, you may want to use QUERY  
PROFILE to examine the profile associations defined on both the configuration  
manager and the managed server. To correct the situation, on the managed server  
Tivoli Storage Manager Messages  
455  
Download from Www.Somanuals.com. All Manuals Search And Download.  
delete the subscription to the profile and define the subscription again. This will  
cause the managed server to be refreshed at the configuration manager’s current  
level.  
ANR3174E  
Communication error with managed server server name.  
Explanation: While receiving or sending information to the specified managed  
server, a communcations error was experienced.  
System Action: Server operation continues. The operation in progress fails.  
User Response: If this error happens often, consult with your network  
administrator. Also check to see that the managed server is up.  
ANR3175W  
Profile profile name is locked and could not be refreshed from configuration  
manager server name.  
Explanation: While receiving configuration refresh information from the specified  
managed server, it was detected that a subscribed-to profile is locked.  
System Action: Server operation continues. Refresh processings skips over this  
profile.  
User Response: Normally, the profile will later be unlocked automatically, or by  
an administrator. If you think that it should not be locked, have ask the  
configuration manager admin to unlock it using the UNLOCK PROFILE command.  
ANR3176W  
Profile profile name is locked and could not be refreshed for managed server  
server name.  
Explanation: While sending configuration refresh information to the specified  
managed server, it was detected that a subscribed-to profile is locked.  
System Action: Server operation continues. Refresh processings skips over this  
profile.  
User Response: If the profile should no longer be locked, use the UNLOCK  
PROFILE command to unlock it.  
ANR3177W  
Server level does not support object in profile profile name.  
Explanation: While receiving configuration refresh information from the  
configuration manager, an object was received that is not supported on this managed  
server.  
System Action: Server operation continues. Refresh processings skips over this  
object. The refresh for the profile fails.  
456  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The configuration manager is at a higher release level than the  
managed server. The managed server subscribed to a profile that contains an  
unsupported object. Delete the subscription to this profile until service can be  
applied to the server to bring it to a higher release level.  
ANR3200E  
command: Command cannot be executed - domain domain name is a managed  
object.  
Explanation: The specified command cannot be executed because it would alter  
the contents of the indicated managed domain. With the exception of policy set  
activation, a managed domain can only be modified using configuration information  
propagated from the configuration manager.  
System Action: The command fails and server operation continues.  
User Response: None.  
ANR3201E  
ANR3202E  
ANR3203E  
command: Domain domain name is a managed object and cannot be deleted.  
Explanation: The indicated domain is a managed object and cannot be deleted on  
the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
command: Domain domain name is a managed object and cannot be updated.  
Explanation: The indicated domain is a managed object and cannot be updated on  
the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
command: Policy set set name in domain domain name is a managed object and  
cannot be deleted.  
Explanation: The indicated policy set is a managed object and cannot be deleted  
on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
Tivoli Storage Manager Messages  
457  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3204E  
ANR3205E  
ANR3206E  
ANR3207E  
ANR3208E  
command: Policy set set name in domain domain name is a managed object and  
cannot be updated.  
Explanation: The indicated policy set is a managed object and cannot be updated  
on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
command: Management class class name in domain domain name, policy set set  
name is a managed object and cannot be deleted.  
Explanation: The indicated management class is a managed object and cannot be  
deleted on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
command: Management class class name in domain domain name, policy set set  
name is a managed object and cannot be updated.  
Explanation: The indicated management class is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
command: Backup copy group group name in domain domain name, policy set set  
name, management class class name is a managed object and cannot be deleted.  
Explanation: The indicated backup copy group is a managed object and cannot be  
deleted on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
command: Archive copy group group name in domain domain name, policy set set  
name, management class class name is a managed object and cannot be deleted.  
Explanation: The indicated archive copy group is a managed object and cannot be  
deleted on the managed server.  
458  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
ANR3209E  
command: Backup copy group group name in domain domain name, policy set set  
name, management class class name is a managed object and cannot be  
updated.  
Explanation: The indicated backup copy group is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
ANR3210E  
command: Archive copy group group name in domain domain name, policy set set  
name, management class class name is a managed object and cannot be  
updated.  
Explanation: The indicated archive copy group is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
ANR3211E  
command: Client schedule schedule name in domain domain name is a managed  
object and cannot be deleted.  
Explanation: The indicated client schedule is a managed object and cannot be  
deleted on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
ANR3212E  
command: Client schedule schedule name in domain domain name is a managed  
object and cannot be updated.  
Explanation: The indicated client schedule is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which domain domain name is associated.  
Tivoli Storage Manager Messages  
459  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3213E  
command: Administrative schedule schedule name is a managed object and  
cannot be deleted.  
Explanation: The indicated administrative schedule is a managed object and  
cannot be deleted on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3214E  
command: Administrative schedule schedule name is a managed object and  
cannot be updated, except to activate or deactivate the schedule.  
Explanation: The indicated administrative schedule is a managed object and  
cannot be updated on the managed server, except to change the active state of the  
schedule.  
System Action: The command fails and server operation continues.  
User Response: To update this object, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3215W  
Managed domain domain name contains at least one node and cannot be  
discarded.  
Explanation: This message is issued while processing a DELETE  
SUBSCRIPTION command with DISCARDOBJECTS=YES. The indicated domain  
cannot be discarded on the managed server because it still contains one or more  
nodes.  
System Action: Domain domain name is not deleted. Policy sets, management  
classes, copy groups, and client schedules belonging to this domain are also not  
deleted.  
User Response: Before this domain can be deleted, nodes in the domain must be  
removed or assigned another domain.  
ANR3216W  
Managed administrative schedule schedule name is active and cannot be  
discarded.  
Explanation: This message is issued while processing a DELETE  
SUBSCRIPTION command with DISCARDOBJECTS=YES. The indicated  
administrative schedule cannot be discarded on the managed server because it is in  
the active state.  
System Action: Administrative schedule schedule name is not deleted.  
460  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Before this administrative schedule can be deleted, it must be  
deactivated using the Update Schedule command.  
ANR3217E  
ANR3218E  
ANR3219E  
ANR3220E  
command: Administrator administrator name is a managed object and cannot be  
removed.  
Explanation: The indicated administrator is a managed object and cannot be  
removed on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To remove this administrator, you can delete the subscription to  
the configuration profiles with which the object is associated.  
command: Administrator administrator name is a managed object and cannot be  
updated.  
Explanation: The indicated administrator is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this administrator, you can delete the subscription to the  
configuration profiles with which the object is associated.  
command: Administrator administrator name is a managed object and cannot be  
renamed.  
Explanation: The indicated administrator is a managed object and cannot be  
renamed on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To rename this administrator, you can delete the subscription to  
the configuration profiles with which the object is associated.  
command: Administrator administrator name is a managed object - authority  
cannot be granted.  
Explanation: The indicated administrator is a managed object. Authority cannot be  
granted to this administrator on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To grant authority to this administrator, you can delete the  
subscription to the configuration profiles with which the object is associated.  
Tivoli Storage Manager Messages  
461  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3221E  
command: Administrator administrator name is a managed object - authority  
cannot be revoked.  
Explanation: The indicated administrator is a managed object. Authority of this  
administrator cannot be revoked on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To revoke authority of this administrator, you can delete the  
subscription to the configuration profiles with which the object is associated.  
ANR3222W  
Managed administrator administrator name is the only system administrator and  
cannot be discarded.  
Explanation: This message is issued while processing a DELETE  
SUBSCRIPTION command with DISCARDOBJECTS=YES. The indicated  
administrator cannot be discarded on the managed server because it is the only  
system administrator.  
System Action: Administrator administrator name is not deleted.  
User Response: Before this administrator can be deleted, another administrator  
must be given system authority.  
ANR3223W  
Managed administrator administrator name is currently accessing the server and  
cannot be discarded.  
Explanation: This message is issued while processing a DELETE  
SUBSCRIPTION command with DISCARDOBJECTS=YES. The indicated  
administrator cannot be discarded on the managed server because it has an active  
session with the server.  
System Action: Administrator administrator name is not deleted.  
User Response: Quit or cancel all sessions for this administrator before discarding  
the administrator definition.  
ANR3224E  
command: Command script command script name is a managed object and  
cannot be deleted.  
Explanation: The indicated command script is a managed object and cannot be  
deleted on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this script, you can delete the subscription to the  
configuration profiles with which the object is associated.  
462  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3225E  
command: Command script command script name is a managed object and  
cannot be updated.  
Explanation: The indicated command script is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this script, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3226E  
command: Command script command script name is a managed object and  
cannot be renamed.  
Explanation: The indicated command script is a managed object and cannot be  
renamed on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To rename this script, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3227E  
command: Option set optionset name is a managed object and cannot be deleted.  
Explanation: The indicated option set is a managed object and cannot be deleted  
on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this option set, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3228E  
command: Option set optionset name is a managed object and cannot be  
updated.  
Explanation: The indicated option set is a managed object and cannot be updated  
on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this option set, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3229E  
command: Command cannot be executed - option set optionset name is a  
managed object.  
Explanation: The specified command cannot be executed because it would alter  
the contents of the indicated managed option set.  
System Action: The command fails and server operation continues.  
Tivoli Storage Manager Messages  
463  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR3230E  
command: Server group group name is a managed object and cannot be deleted.  
Explanation: The indicated server group is a managed object and cannot be  
deleted on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To delete this server group, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3231E  
command: Server group group name is a managed object and cannot be  
updated.  
Explanation: The indicated server group is a managed object and cannot be  
updated on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To update this server group, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3232E  
command: Server group group name is a managed object and cannot be  
renamed.  
Explanation: The indicated server group is a managed object and cannot be  
renamed on the managed server.  
System Action: The command fails and server operation continues.  
User Response: To rename this server group, you can delete the subscription to  
the configuration profiles with which the object is associated.  
ANR3233E  
command: Command cannot be executed - server group group name is a  
managed object.  
Explanation: The specified command cannot be executed because it would alter  
the membership of the indicated managed server group.  
System Action: The command fails and server operation continues.  
User Response: None.  
ANR3234E  
command: Server server name is a managed object and cannot be deleted.  
Explanation: The indicated server is a managed object and cannot be deleted on  
the managed server.  
464  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command fails and server operation continues.  
User Response: To delete this object, you can delete the subscription to the  
configuration profiles with which the object is associated.  
ANR3235E  
command: Server server name is a managed object - one or more specified  
attributes cannot be updated.  
Explanation: Because the indicated server is a managed object, certain attributes  
cannot be updated on the managed server. These attributes are:  
SERVERPASSWORD, HLADDRESS, LLADDRESS, COMMMETHOD,  
DESCRIPTION, URL, and ALLOWREPLACE.  
System Action: The command fails and server operation continues.  
User Response: You can restrict the update to attributes that can be updated on the  
managed server. For example, the PASSWORD, NODENAME, FORCESYNC, and  
DELGRACEPERIOD attributes can be updated, even if the server is a managed  
object. Alternatively, you can delete the subscription to the configuration profiles  
with which the object is associated, so that the server is no longer a managed  
object.  
ANR3236W  
Server server name is currently in use and cannot be discarded.  
Explanation: This message is issued while processing a DELETE  
SUBSCRIPTION command with DISCARDOBJECTS=YES. The indicated server  
cannot be discarded on the managed server because server name is in use. This  
could occur if the managed server has an active connection to server name or if the  
managed server has a device class with DEVTYPE=SERVER that refers to server  
name.  
System Action: Server server name is not deleted.  
User Response: Before server name can be deleted, the managed server must not  
have a connection to that server and the managed server cannot have any  
device-class references to that server.  
ANR3237W  
Server server name is the event server and cannot be discarded.  
Explanation: This message is issued while processing a DELETE  
SUBSCRIPTION command with DISCARDOBJECTS=YES. The indicated server  
cannot be discarded because it is the event server for the managed server.  
System Action: Server server name is not deleted.  
User Response: Before server name can be deleted, the DELETE  
EVENTSERVER command must be used to remove the event server reference to  
server name.  
Tivoli Storage Manager Messages  
465  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3238E  
command: This object cannot be renamed because it is associated with one or  
more configuration profiles.  
Explanation: This message is issued on a configuration manager when an attempt  
is made to rename an object that is associated with one or more configuration  
profiles. Associated objects cannot be renamed because the enterprise configuration  
facility does not support renaming of objects.  
System Action: The command fails and server operation continues.  
User Response: If you must change the object name you can delete the object,  
define it with a new name, and then define a profile association to the new object  
(unless a wildcard profile association already exists). This will cause the object to  
be deleted and re-defined on managed servers with subscriptions to the profiles with  
which this object is associated.  
ANR3350W  
Locally defined domain domain name contains at least one node and cannot be  
replaced with a definition from the configuration manager.  
Explanation: During configuration refresh processing the indicated locally defined  
domain could not be replaced with a definition from the configuration manager. The  
domain definition was not replaced because the domain still contains one or more  
assigned nodes.  
System Action: Refresh processing continues, but this domain is not replaced. The  
system will attempt to replace the local domain during later configuration refresh  
operations.  
User Response: If you want existing nodes to be assigned to the domain from the  
configuration manager, you can temporarily assign them to another domain. After  
the domain definition has successfully been propagated from the configuration  
manager, reassign the nodes to the new domain. Alternatively, if you want to  
prevent further attempts to replace the local domain definition during configuration  
refresh processing, delete the subscription to the profiles with which domain domain  
name is associated.  
ANR3351W  
Managed domain domain name contains at least one node and cannot be deleted  
during configuration refresh processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to remove the indicated domain because it has been deleted from  
the configuration manager or because the profile association no longer exists. The  
domain could not be deleted on the managed server because it still contains one or  
more nodes.  
System Action: Refresh processing continues, but this domain is not deleted. The  
system will attempt to delete the domain during later configuration refresh  
operations.  
466  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Assign nodes in this domain to another domain. Alternatively, you  
can delete the subscription to the profiles with which domain domain name is  
associated.  
ANR3352I  
Locally defined domain domain name replaced during configuration refresh  
processing.  
Explanation: During configuration refresh processing, a local domain definition  
was replaced with a definition from the configuration manager. The system also  
deleted all policy sets, management classes, copy groups, and client schedules  
belonging to the locally defined domain and added definitions from the  
configuration manager.  
System Action: None.  
User Response: None.  
ANR3353I  
Managed domain domain name deleted during configuration refresh processing.  
Explanation: During configuration refresh processing, the indicated managed  
domain was removed from the managed server. This occurred either because the  
domain has been deleted from the configuration manager or because the profile  
association no longer exists. The system also deleted all policy sets, management  
classes, copy groups, and client schedules belonging to the managed domain.  
System Action: None.  
User Response: None.  
ANR3354W  
Locally defined administrative schedule schedule name is active and cannot be  
replaced with a definition from the configuration manager.  
Explanation: During configuration refresh processing the indicated locally defined  
administrative schedule could not be replaced with a definition from the  
configuration manager. The schedule definition was not replaced because the  
schedule is in the active state.  
System Action: Refresh processing continues, but this administrative schedule is  
not replaced. The system will attempt to replace the local administrative schedule  
during later configuration refresh operations.  
User Response: If you want this administrative schedule to be replaced with the  
schedule definition from the configuration manager, deactivate the local schedule  
using the Update Schedule command. After the administrative schedule definition  
has successfully been propagated from the configuration manager, you can activate  
the new schedule. Alternatively, if you want to prevent further attempts to replace  
the local schedule definition during configuration refresh processing, delete the  
subscription to the profiles with which the schedule name is associated.  
Tivoli Storage Manager Messages  
467  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3355W  
Managed administrative schedule schedule name is active and cannot be deleted  
during configuration refresh processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to remove the indicated administrative schedule because it has  
been deleted from the configuration manager or because the profile association no  
longer exists. The schedule could not be deleted on the managed server because the  
schedule is in the active state.  
System Action: Refresh processing continues, but this schedule is not deleted. The  
system will attempt to delete the administrative schedule during later configuration  
refresh operations.  
User Response: If you want this administrative schedule to be deleted in  
accordance with changes that have been made on the configuration manager,  
deactivate the managed schedule using the Update Schedule command.  
Alternatively, if you want to prevent further attempts to delete the managed schedule  
definition during configuration refresh processing, delete the subscription to the  
profiles with which the schedule name is associated.  
ANR3356I  
Locally defined administrative schedule schedule name replaced during  
configuration refresh processing.  
Explanation: During configuration refresh processing, a local administrative  
schedule definition was replaced with a definition from the configuration manager.  
System Action: None.  
User Response: None.  
ANR3357I  
Managed administrative schedule schedule name deleted during configuration  
refresh processing.  
Explanation: During configuration refresh processing, the indicated managed  
administrative schedule was removed from the managed server. This occurred either  
because the schedule has been deleted from the configuration manager or because  
the profile association no longer exists.  
System Action: None.  
User Response: None.  
ANR3358W  
Locally defined administrator administrator name is the only system  
administrator and cannot be replaced with a definition from the configuration  
manager.  
Explanation: During configuration refresh processing the indicated locally defined  
administrator could not be replaced with a definition from the configuration  
468  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
manager. The administrator definition was not replaced because it is the only system  
administrator and the definition from the configuration manager does not include  
system authority.  
System Action: Refresh processing continues, but this administrator definition is  
not replaced. The system will attempt to replace the local administrator definition  
during later configuration refresh operations.  
User Response: If you want this administrator definition to be replaced with a  
definition from the configuration manager, you can grant system authority to another  
administrator. Alternatively, if you want to prevent further attempts to replace the  
local administrator definition during configuration refresh processing, delete the  
subscription to the profiles with which administrator administrator name is  
associated.  
ANR3359W  
Managed system administrator administrator name is the only system  
administrator and cannot be deleted during configuration refresh processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to remove the indicated administrator because it has been deleted  
from the configuration manager or because the profile association no longer exists.  
The administrator could not be deleted on the managed server because it is the only  
system administrator.  
System Action: Refresh processing continues, but this administrator is not deleted.  
The system will attempt to delete the administrator during later configuration refresh  
operations.  
User Response: Grant system authority to another administrator. Alternatively, you  
can delete the subscription to the profiles with which administrator administrator  
name is associated.  
ANR3360W  
Managed system administrator administrator name is the only system  
administrator - authority cannot be revoked during configuration refresh  
processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to revoke authority for the indicated administrator because  
authority has been revoked on the configuration manager. The authority of the  
administrator could not be revoked on the managed server because this is the only  
system administrator.  
System Action: Refresh processing continues, but authority is not revoked for this  
administrator. The system will attempt to revoke administrator during later  
configuration refresh operations.  
Tivoli Storage Manager Messages  
469  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Grant system authority to another administrator. Alternatively, you  
can delete the subscription to the profiles with which administrator administrator  
name is associated.  
ANR3361I  
Locally defined administrator administrator name replaced during configuration  
refresh processing.  
Explanation: During configuration refresh processing, a local administrator  
definition was replaced with a definition from the configuration manager.  
System Action: None.  
User Response: None.  
ANR3362I  
Managed administrator administrator name deleted during configuration refresh  
processing.  
Explanation: During configuration refresh processing, the indicated managed  
administrator was removed from the managed server. This occurred either because  
the administrator has been deleted from the configuration manager or because the  
profile association no longer exists.  
System Action: None.  
User Response: None.  
ANR3363W  
Managed administrator administrator name is currently accessing the server and  
cannot be deleted during configuration refresh processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to remove the indicated administrator because it has been deleted  
from the configuration manager or because the profile association no longer exists.  
The administrator could not be deleted on the managed server because it currently  
has an active session with the server.  
System Action: Refresh processing continues, but this administrator is not deleted.  
The system will attempt to delete the administrator during later configuration refresh  
operations.  
User Response: Quit or cancel all sessions for the indicated administrator.  
Alternatively, you can delete the subscription to the profiles with which  
administrator administrator name is associated.  
ANR3364W  
Administrator administrator name has been removed. This administrator has  
defined or updated administrative schedules that will fail when executed.  
Explanation: This message is issued during configuration refresh processing or as  
a result of a DELETE SUBSCRIPTION command with the  
470  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISCARDOBJECTS=YES option. The indicated managed administrator was  
removed from the server, but this administrator owns one or more administrative  
schedules. These schedules will fail when executed in the future because they do not  
belong to a valid administrator.  
System Action: The indicated administrator was removed.  
User Response: Use the QUERY SCHEDULE command OR an SQL SELECT  
statement on the ADMIN_SCHEDULES table to determine which schedules were  
last updated by the administrator. Use the UPDATE SCHEDULE command to  
update those schedules under an administrator that has authority to execute them, or  
use the DELETE SCHEDULE command to remove the schedules.  
ANR3365I  
Locally defined command script command script name replaced during  
configuration refresh processing.  
Explanation: During configuration refresh processing, a local command script  
definition was replaced with a definition from the configuration manager.  
System Action: None.  
User Response: None.  
ANR3366I  
Managed command script command script name deleted during configuration  
refresh processing.  
Explanation: During configuration refresh processing, the indicated managed  
command script was removed from the managed server. This occurred either  
because the script has been deleted from the configuration manager or because the  
profile association no longer exists.  
System Action: None.  
User Response: None.  
ANR3367I  
Locally defined option set option set name replaced during configuration refresh  
processing.  
Explanation: During configuration refresh processing, a local option set definition  
was replaced with a definition from the configuration manager.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
471  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3368I  
Managed option set option set name deleted during configuration refresh  
processing.  
Explanation: During configuration refresh processing, the indicated managed  
option set was removed from the managed server. This occurred either because the  
option set has been deleted from the configuration manager or because the profile  
association no longer exists.  
System Action: None.  
User Response: None.  
ANR3369I  
Locally defined server group group name replaced during configuration refresh  
processing.  
Explanation: During configuration refresh processing, a local server group  
definition was replaced with a definition from the configuration manager.  
System Action: None.  
User Response: None.  
ANR3370I  
Managed server group group name deleted during configuration refresh  
processing.  
Explanation: During configuration refresh processing, the indicated managed  
server group was removed from the managed server. This occurred either because  
the server group has been deleted from the configuration manager or because the  
profile association no longer exists.  
System Action: None.  
User Response: None.  
ANR3371W  
Server group group name cannot be defined during configuration refresh  
processing because a server already exists with this name.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to define the indicated server group on a managed server. The  
server group could not be defined because a server definition with the same name  
already exists on the managed server.  
System Action: Refresh processing continues, but this server group is not defined.  
The system will attempt to define the server group during later configuration refresh  
operations.  
User Response: You can delete the subscription to the profile with which the  
indicated server group is associated or delete the conflicting server definition on the  
472  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
managed server. Alternatively, you can rename the server group on the configuration  
manager, after first deleting the profile association for that server group.  
ANR3372I  
Locally defined server server name replaced during configuration refresh  
processing.  
Explanation: During configuration refresh processing, a local server definition was  
replaced with a definition from the configuration manager.  
System Action: None.  
User Response: None.  
ANR3373I  
Server server name deleted during configuration refresh processing.  
Explanation: During configuration refresh processing, the definition for managed  
object server name was removed from the managed server. This occurred either  
because server name has been deleted from the configuration manager or because  
the profile association no longer exists.  
System Action: None.  
User Response: None.  
ANR3374I  
Server group group name replaced with server server name during configuration  
refresh processing.  
Explanation: During configuration refresh processing, a server group definition  
was replaced with a server definition from the configuration manager. The server  
has the same name as the deleted server group.  
System Action: None.  
User Response: None.  
ANR3375W  
Server server name is currently in use cannot be deleted during configuration  
refresh processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to remove the indicated server definition because it has been  
deleted from the configuration manager or because the profile association no longer  
exists. The indicated server could not be deleted on the managed server because  
server name is in use. This could occur if the managed server has an active  
connection to server name or if the managed server has a device class with  
DEVTYPE=SERVER that refers to server name.  
System Action: Refresh processing continues, but this server definition is not  
deleted. The system will attempt to delete the server during later configuration  
refresh operations.  
Tivoli Storage Manager Messages  
473  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Before server name can be deleted, the managed server must not  
have a connection to that server and the managed server cannot have any  
device-class references to that server.  
ANR3376W  
Server server name is the event server and cannot be deleted during  
configuration refresh processing.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to remove the indicated server definition because it has been  
deleted from the configuration manager or because the profile association no longer  
exists. The indicated server could not be deleted on the managed server because it is  
the event server for the managed server.  
System Action: Refresh processing continues, but this server definition is not  
deleted. The system will attempt to delete the server during later configuration  
refresh operations.  
User Response: Before server name can be deleted, the DELETE  
EVENTSERVER command must be used to remove the event server reference to  
server name.  
ANR3377W  
Replacement of local server server name with a definition from the  
configuration manager is not allowed.  
Explanation: During configuration refresh processing, the enterprise configuration  
facility attempted to replace the indicated server definition with a definition from  
the configuration manager. This operation could not be performed because  
ALLOWREPLACE=NO for the indicated server.  
System Action: Refresh processing continues, but this server definition is not  
replaced. The system will attempt to replace the server definition during later  
configuration refresh operations.  
User Response: Before the local server definition for server name can be replaced  
with a definition from the configuration manager, the UPDATE SERVER command  
must be used to set the ALLOWREPLACE attribute to ON.  
ANR3470I  
Command: Auditing enterprise configuration definitions.  
Explanation: The server has started to audit database definitions used by the  
enterprise configuration facility.  
System Action: Server database audit operation continues.  
User Response: None.  
474  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3471E  
Audit command: Enterprise configuration global attributes are missing.  
Explanation: A database audit process finds that the global attributes used by the  
enterprise configuration facility are missing.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES specified so that the  
enterprise configuration global attributes can be recreated.  
ANR3472I  
Audit command: Enterprise configuration global attributes are missing -  
attributes will be recreated using available database information or default  
values.  
Explanation: A database audit process finds that the global attributes used by the  
enterprise configuration facility are missing. Because FIX=YES has been specified  
on the AUDIT command, these attributes will be recreated using available  
information from the database or default values.  
System Action: Audit processing continues.  
User Response: When the audit completes, you can use the QUERY STATUS  
command to examine the values set for the enterprise configuration global attributes.  
Then use the appropriate SET command to change the attributes, if desired.  
ANR3473E  
Audit command: Enterprise configuration global attribute(s) are incorrect.  
Explanation: A database audit process finds that global attributes used by the  
enterprise configuration facility are incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES specified so that the  
enterprise configuration global attributes can be corrected.  
ANR3474I  
Audit command: Enterprise configuration global attribute(s) are incorrect -  
attributes will be corrected using available database information or default  
values.  
Explanation: A database audit process finds that global attributes used by the  
enterprise configuration facility are incorrect. Because FIX=YES has been specified  
on the AUDIT command, these attributes will be corrected using available  
information from the database or default values.  
System Action: Audit processing continues.  
User Response: When the audit completes, you can use the QUERY STATUS  
command to examine the values set for the enterprise configuration global attributes.  
Then use the appropriate SET command to change the attributes, if desired.  
Tivoli Storage Manager Messages  
475  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3475E  
Audit command: Extraneous profile information found.  
Explanation: A database audit process finds extraneous configuration profile  
information.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information is deleted.  
ANR3476E  
Audit command: Extraneous profile information found - information will be  
deleted.  
Explanation: A database audit process finds extraneous configuration profile  
information. Because FIX=YES has been specified for the audit command, the  
extraneous information will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR3477E  
ANR3478E  
ANR3479E  
Audit command: Profile information is inconsistent.  
Explanation: A database audit process detects inconsistent configuration profile  
information. This information can be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be corrected.  
Audit command: Profile information is inconsistent - it will be corrected.  
Explanation: A database audit process detects inconsistent configuration profile  
information. Because FIX=YES has been specified for the audit command, the  
information will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Profile association information is missing.  
Explanation: A database audit process detects missing profile association  
information. This information can be recreated.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be recreated.  
476  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3480E  
ANR3481E  
ANR3482E  
Audit command: Profile association information is missing - it will be recreated.  
Explanation: A database audit process detects missing profile association  
information. Because FIX=YES has been specified for the audit command, the  
information will be recreated.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Extraneous profile association information found.  
Explanation: A database audit process finds extraneous profile association  
information.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information is deleted.  
Audit command: Extraneous profile association information found - information  
will be deleted.  
Explanation: A database audit process finds extraneous profile association  
information. Because FIX=YES has been specified for the audit command, the  
extraneous information will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR3483E  
Audit command: Subscription information is inconsistent.  
Explanation: A database audit process detects inconsistent profile subscription  
information. This information can be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be corrected.  
ANR3484E  
Audit command: Profile subscription information is inconsistent - it will be  
corrected.  
Explanation: A database audit process detects inconsistent profile subscription  
information. Because FIX=YES has been specified for the audit command, the  
information will be corrected.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
477  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR3485E  
Audit command: Profile subscriptions were found to more than one  
configuration manager.  
Explanation: A database audit process determines that a managed server has  
subscriptions to more than one configuration manager. This may cause the enterprise  
configuration facility to behave in an unpredictable manner.  
System Action: Audit processing continues.  
User Response: Delete subscriptions for all but one configuration manager. To do  
this, it may be necessary to delete subscriptions to all configuration managers and  
then define the desired subscriptions.  
ANR3500I  
ANR3501I  
Backup set for node node name as set name being generated.  
Explanation: The named object set is being created for the specified node.  
System Action: The server generates a backup set.  
User Response: None.  
Backup set for node name as set name completed successfully - processed files  
files.  
Explanation: The named object set was successfully created for the specified  
node. The number of files processed is specified.  
System Action: None.  
User Response: None.  
ANR3502W  
Backup set for node name as set name completed with file processing errors -  
processed files files with error files files skipped.  
Explanation: The named object set was successfully created for the specified  
node. However, during processing errors were encountered accessing some files -  
these files were skipped.  
System Action: None.  
User Response: Evaluate other server messages for an indication of why the files  
where skipped. Files can be skipped because of failures locking those files or for  
other more serious problems. First, re-try the command and see if it completes  
without any skipped files. If you are unable to generate the backup set without  
skipping files, please contact your local service representative for assistance.  
478  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3503E  
Generation of backup set for node name as set name failed.  
Explanation: The named object for the specified node was not created. An error  
was encountered causing the creation of this object set not to complete successfully.  
System Action: Server operation continues.  
User Response: Evaluate other messages that were issued and try to determine the  
cause of the failure. After determining the cause of the failure, retry the command.  
If the cause can not be determined, please contact your local service representative.  
If ANR3504W was received, than an error occurred while logging the volumes used  
to the server volume history. It is possible to issue a DEFINE BACKUPSET listing  
these volumes. That would cause the server to create the necessary entries for this  
backup set on this server.  
ANR3504W  
Backup set for node name as set name was not able to log the volumes used for  
this operation to the server volume history.  
Explanation: The named object for the specified node was created. However,  
when the process attempted to add the volumes, used for this operation to the  
volume history for the server, an error occurred and this could not be completed.  
System Action: Server operation continues.  
User Response: Review other messages issued to determine which volumes where  
used for to generate this backup set. The volumes can be inserted into the server  
volume history for use by issuing a DEFINE BACKUPSET and listing these  
volumes. This will also allow this backup set to be queried from a client as well  
since there is not a server entry for this backup set. Only issue the DEFINE  
BACKUPSET if this generate backup set operation completed successfully.  
ANR3505I  
ANR3507I  
Backup set for node name as set name used volume volume name.  
Explanation: The named object for the specified node used the specified volume.  
System Action: Server operation continues.  
User Response: None.  
Cancel in progress  
Explanation: This message is displayed in response to a QUERY PROCESS  
command, and indicates that a generate backupset process has been canceled. The  
process will end shortly.  
System Action: The process terminates and server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
479  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3508W  
Generation of backup set for node name as set name failed - no filespaces to  
process.  
Explanation: The named object for the specified node was not created. No  
filespaces were available to process.  
System Action: Server operation continues.  
User Response: Reissue the command against a node that has filespaces associated  
with it. If no filespaces exist for a given node, than there is no file data to write to  
the backupset.  
ANR3509E  
ANR3510E  
ANR3511E  
Command: Error encountered in accessing data storage - device class device  
class name is not defined.  
Explanation: During command command processing, an error occurred because  
the specified device class is not defined.  
System Action: The command command is ended and server operation continues.  
User Response: Make sure the specified device class is defined.  
Command: Error encountered in accessing data storage - disk volume specified.  
Explanation: During command command processing, an error occurred because a  
specified volume is a disk volume rather than a tape volume.  
System Action: The command command is ended and server operation continues.  
User Response: Make sure that all volumes specified for the command command  
are tape volumes.  
Command: Error encountered in accessing data storage - invalid volume name  
specified.  
Explanation: The server encounters an error in accessing data storage while  
processing command command. The error occurred because an attempt has been  
made to access a volume with an invalid name.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Issue the command with a valid volume name.  
ANR3512E  
Command: Error encountered in accessing data storage - insufficient number of  
mount points available for removable media.  
Explanation: During command command processing, the server cannot allocate  
sufficient mount points.  
480  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: If necessary, make more mount points available.  
ANR3513E  
Command: Output error encountered in accessing data storage.  
Explanation: The command command operation ends because an error has been  
encountered by the server in writing to a device. Possible reasons include:  
I/O error writing to a device  
No storage space.  
System Action: The command command operation ends and server operation  
continues.  
User Response: Query the activity log to find messages preceding this one to  
determine the cause of the error. After the problem is corrected, the command can  
be retried.  
ANR3514E  
Command: Data transfer was interrupted in accessing data storage.  
Explanation: The database transaction associated with command command  
operation failed because data transfer to or from data storage was interrupted by an  
external event.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Examine the messages issued prior to this message to determine  
why the data transfer was interrupted. Reissue the command command after the  
problem is resolved.  
ANR3515E  
Command: Error encountered in accessing data storage - volume already in use.  
Explanation: During command command processing, a volume cannot be used  
because it is already defined in a storage pool, or has been previously used by an  
export, database dump, or database backup operation (as recorded in the volume  
history) or is in use by another process.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Specify a volume that is not in use or defined in a storage pool,  
and that has not been previously used for an export, database dump, or database  
backup operation as recorded in the server volume history information. Use the  
QUERY VOLUME command to display the names of volumes that are defined to  
Tivoli Storage Manager Messages  
481  
Download from Www.Somanuals.com. All Manuals Search And Download.  
server storage pools. Use the QUERY VOLHISTORY command to display the  
names of volumes that have been used for export, database dump, or database  
backup operations.  
ANR3516E  
Command: Out of space on sequential media, scratch media could not be  
mounted.  
Explanation: During command command processing, the process encounters an  
out-of-space condition writing to the sequential media. Command command ends  
when there is no more space on the sequential media for storing data and  
SCRATCH=NO has been specified on command command.  
System Action: Command command processing ends. Server processing continues.  
User Response: Reissue the command and specify SCRATCH=YES or specify  
additional volume names on the command.  
ANR3517E  
Command: Error encountered in accessing data storage - required volume was  
not mounted.  
Explanation: During command command processing, a required volume cannot be  
mounted. The mount request may have been canceled.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Issue the command again and make sure the necessary volumes  
are accessible.  
ANR3518I  
Command: Processing canceled before completion.  
Explanation: The background process to service the command command has been  
canceled with the CANCEL PROCESS command.  
System Action: Processing for the command command ends. Statistics on the  
number and type of objects moved, together with the total number of bytes copied,  
are displayed on the server console following this message.  
User Response: None.  
ANR3519E  
Command: Insufficient memory available in accessing data storage.  
Explanation: The server encounters a memory shortage in accessing data storage  
during command command operation.  
System Action: The command command operation ends and server operation  
continues.  
482  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR3520E  
Command: Internal error encountered in accessing data storage.  
Explanation: The server encounters an internal error in accessing data storage  
while processing command command operation.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Use the QUERY ACTLOG command to examine messages prior  
to this error to determine the cause of the data storage failure. If the failure can be  
found and resolved, reissue the command command operation. If the failure cannot  
be found, contact your service representative for assistance in resolving the problem.  
ANR3521W  
BackupSet command: Data storage retrieve or restore failed - data integrity  
error detected.  
Explanation: The server ends an backup set operation because an internal database  
integrity error has been encountered on the server.  
System Action: The server ends the backup set operation and continues operation.  
User Response: Contact your service representative.  
ANR3522W  
Command: Retrieve or restore failed - file was deleted from data storage during  
retrieval.  
Explanation: The server ends a file retrieval operation for the specified command  
because the file has been deleted from data storage by another process before  
retrieval is complete.  
System Action: The server ends the command and continues operation.  
User Response: Contact your administrator to find out if DELETE FILESPACE,  
DELETE VOLUME, or inventory expiration processes are running; these processes  
can delete data storage files during retrieval. Reissue the command after these  
processes have been completed or canceled.  
ANR3523W  
Backup set command: Retrieve failed - error on input storage device.  
Explanation: The server ends a backup set operation for the specified session  
because an I/O error has been encountered by the server in reading from a device.  
The object for which the I/O was issued is reported in a later message.  
System Action: Backup set processing skips this file, and continues operation.  
Tivoli Storage Manager Messages  
483  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Query the activity log to find messages preceding this one that  
specify the device that is failing. Storage pool volumes can be varied offline (by  
using the VARY OFFLINE command), or the server may need to be shut down with  
the HALT command to correct the hardware problem.  
ANR3524W  
Backup set command: Transaction failed - data transfer interrupted.  
Explanation: The database transaction associated with a backup set operation  
failed because data transfer to or from data storage was interrupted by an external  
event.  
System Action: The backup set operation is ended and server operation continues.  
User Response: Examine the messages issued prior to this message to determine  
why the data transfer was interrupted. Attempt the backup set operation again after  
problem is resolved.  
ANR3525W  
Backup set command: Transaction failed - storage media inaccessible.  
Explanation: The server ends a transaction for an backup set operation because  
storage volumes are not available in the storage pools in which the client files are to  
be stored.  
System Action: The server ends the backup set operation and server operation  
continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy. The  
VARY ONLINE command can be used to vary offline storage volumes online in the  
storage hierarchy to make them available for file storage.  
ANR3526E  
Backup set command: Error encountered in accessing data storage - volume  
cannot be used.  
Explanation: During backup set processing, a volume has been mounted but  
cannot be used.  
System Action: The backup set operation is ended and server operation continues.  
User Response: Query the activity log for messages preceding this one that give  
additional information. Make sure a usable volume is specified and mounted.  
ANR3527E  
Backup set command operation terminated - incomplete input volume list.  
Explanation: The list of volumes needed to process the command was incomplete.  
At least one volume needed for the operation is missing from the end of the list.  
System Action: The command operation is ended.  
484  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command again and make sure the necessary volumes  
are included in the volume list.  
ANR3528E  
Backup set command: Media not accessible in accessing data storage.  
Explanation: The server ends a transaction for a backup set operation because  
storage volumes are not available in the storage pools in which the client files are to  
be stored.  
System Action: The server ends the backup set operation and server operation  
continues.  
User Response: An authorized administrator can issue the DEFINE VOLUME  
command to add storage to one or more storage pools in the storage hierarchy. The  
VARY ONLINE command can be used to vary offline storage volumes online in the  
storage hierarchy to make them available for file storage.  
ANR3529W  
Generate backupset skipping damaged file on volume volume name: Node node  
name, Type file type, File space filespace name, File name file name.  
Explanation: During generate backupset process, a file is encountered that was  
previously found to be damaged. If this file is part of an aggregate, the entire  
aggregate was previously marked damaged, possibly because an integrity error was  
detected for some other file within the aggregate.  
System Action: The damaged file is not added to the backupset.  
User Response: Audit the indicated volume with FIX=NO to verify that the file is  
damaged. The audit will reset the file status if the file is found to be undamaged  
during the audit. If the file is part of an aggregate, the audit will reset the aggregate  
status if the entire aggregate is found to be undamaged. If the file is reset to the  
undamaged state and it is important that the file be included in the backupset, rerun  
the generate backupset command. If, however, the audit does not clear the damaged  
state of the file and if this volume is in a primary storage pool that has previously  
been backed up to a copy storage pool, attempt to restore damaged files by using  
the RESTORE STGPOOL command. If it is still important that the file be included  
in the backupset, rerun the generate backupset command.  
ANR3540E  
Object set set node:set name was not found for session session number, node.  
Explanation: The indicated session id requested to restore the object set. The  
object set was not found on the server.  
System Action: The error is returned to the client.  
User Response: None.  
Tivoli Storage Manager Messages  
485  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR3541E  
ANR3542E  
ANR3543E  
ANR3550E  
Error error code occurred opening object set set node:set name for session  
session number, node.  
Explanation: An error occurred while opening the indicated object set.  
System Action: An error is returned to the client.  
User Response: Correct the problem reported by previous messages, if possible.  
Error error code occurred reading object set set node:set name for session  
session number, node.  
Explanation: An error occurred while reading the indicated object set.  
System Action: An error is returned to the client.  
User Response: Correct the problem reported by previous messages, if possible.  
Error error code occurred while sending entries from object set set node:set  
name for session session number, node.  
Explanation: An error occurred while sending entries for the indicated object set.  
System Action: An error is returned to the client.  
User Response: Correct the problem reported by previous messages, if possible.  
Definition of backup set set name for node name failed because it has an  
unknown format.  
Explanation: The named object for the specified node was not defined. It was  
generated on a server that is at a higher level than this server and contains data that  
cannot be properly interpreted by this server.  
System Action: Server operation continues.  
User Response: Define the object on a server that is compatible with the server  
that generated the object, or upgrade this server to be compatible with the server  
that generated the object.  
ANR4000I  
Dump command: Database dump process started.  
Explanation: The database dump process has started.  
System Action: The server dumps the contents of the database to a file or  
removable media.  
User Response: None.  
486  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4001I  
ANR4002I  
Dump command: Database dump process completed.  
Explanation: The database dump process has ended.  
System Action: The server completes processing.  
User Response: None.  
Dump command: Database dump process terminated due to error (error  
indicator).  
Explanation: The database dump process has ended prematurely due to an error.  
System Action: The server ends dump processing.  
User Response: Examine previously issued messages to determine if an error can  
be corrected, such as an output error. If you cannot resolve the error, contact your  
service representative.  
ANR4003I  
Load command: Database load process started.  
Explanation: The database load process has started.  
System Action: The server loads the contents of the database from a file or  
removable media.  
User Response: None.  
ANR4004I  
ANR4005E  
Load command: Database load process completed.  
Explanation: The database load process has ended.  
System Action: The server completes processing.  
User Response: None.  
Load command: Database load process terminated due to error (error indicator).  
Explanation: The database load process has ended prematurely due to an error.  
System Action: The server ends load processing.  
User Response: Examine previously issued messages to determine if an error can  
be corrected, such as a syntax error. If you cannot resolve the error, contact your  
service representative.  
Tivoli Storage Manager Messages  
487  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4006I  
Command: Volume volume number written by process is volume name.  
Explanation: A sequential data process wrote to the volume named in the series of  
one or more volumes that were used to store output. The volume’s position in the  
series in indicated by the volume number reported.  
System Action: The server ends processing.  
User Response: None.  
ANR4007E  
Command: A transaction error was encountered in recording volume usage  
history.  
Explanation: The command process encounters a database transaction error in  
recording the names of the volumes used for the process in the server database.  
System Action: The server ends processing.  
User Response: Examine previously issued messages to determine if there is an  
error that can be corrected, such as a syntax error. If you cannot resolve the error,  
contact your service representative. The volumes used by the process are valid for  
the corresponding input process, but are not recorded in sequential volume history  
lists generated by the server.  
ANR4008W  
Load command: Database object object name does not exist.  
Explanation: The database load process attempts to delete a database object, but  
the object does not exist.  
System Action: Database processing continues.  
User Response: None.  
ANR4009E  
Load command: Database object object name cannot be deleted because it is in  
use by another process.  
Explanation: The database load process attempts to delete a database object, but  
the object is currently being used by another process.  
System Action: Database processing ends.  
User Response: Reissue the command. If it fails, contact your service  
representative.  
ANR4010E  
Dump/load command: Database dump/load processing failed - insufficient  
memory.  
Explanation: The database dump/load process fails due to insufficient memory.  
System Action: Database processing ends.  
488  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Allocate additional storage to the server. There are two ways to  
do this:  
Increase the size of the server’s virtual machine (for VM), or region size (for  
MVS). For AIX, ensure that there is sufficient paging space. You may also use  
SMIT to determine if the number of applications is causing a memory shortage.  
For OS/2, ensure that there is sufficient space for the OS/2 SWAPPER.DAT file.  
Check your CONFIG.SYS for the SWAPPATH statement to determine where  
your SWAPPER.DAT file is located and then determine how much space is left  
on the drive.  
Decrease the amount of space allocated to the server’s database or log buffer  
pool. To do this, update the value of the BUFPOOLSIZE or LOGPOOLSIZE  
parameters in the server options file and restart the server. Note that each page  
causes an additional 4K page to be allocated for the specified buffer pool.  
Reducing the pool sizes requires more I/O to service the same amount of data;  
some performance degradation may result.  
ANR4011W  
Dump command: Database page page number is invalid - it will be skipped.  
Explanation: The specified page is invalid, and it will not be used during dump  
processing.  
System Action: Processing continues.  
User Response: None.  
ANR4012W  
ANR4013I  
Dump command: Database page page number is damaged.  
Explanation: The specified database page is damaged; it will not be dumped.  
System Action: Processing continues.  
User Response: None.  
Dump command: Dumped number of entries database entries (cumulative).  
Explanation: This message indicates the number of database entries that have  
been dumped so far during database dump processing.  
System Action: Server processing continues.  
User Response: None.  
ANR4014E  
Load command: The specified input volume does not contain a server database  
dump.  
Explanation: The specified volume does not contain a dump created from the  
database dump command.  
Tivoli Storage Manager Messages  
489  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing ends.  
User Response: None.  
ANR4015E  
Load command: Invalid record format (format code) detected.  
Explanation: During processing of command load command, an invalid record  
type is detected when reading the dumped information from the dump media.  
System Action: Processing of the command ends.  
User Response: Examine the server messages issued prior to this message to  
determine the source of the error. On MVS or VM, the LOADDB command syntax  
may be specified by using a ddname or by specifying a device class name. You  
must use the same method that was used when the data base was originally dumped.  
If you did not, this error message will be displayed. Try loading the data base by  
using the other method of syntax (devclass). If the error cannot be isolated and  
resolved, contact your service representative.  
ANR4016E  
Load command: Invalid header sequence number detected in database dump.  
Expected expected sequence number; Actual actual sequence number.  
Explanation: During processing of command load command, an invalid sequence  
number is detected when reading the dumped information from the dump media.  
System Action: Processing of the command ends.  
User Response: Examine previously issued server messages to determine the  
source of the error. If the error cannot be isolated and resolved, contact your service  
representative.  
ANR4017E  
Load command: Invalid record type record type read from database dump data.  
Explanation: The server database load process encounters an invalid record in  
reading data from the dump media.  
System Action: The database load process ends.  
User Response: Examine previously issued server messages to determine the  
source of the error. If the error cannot be isolated and resolved, contact your service  
representative.  
ANR4018E  
Load command: Load processing failed - insufficient recovery log space.  
Explanation: The load process fails due to insufficient recovery log space.  
System Action: Database load processing ends.  
User Response: Reinstall the server and specify a larger recovery log and reissue  
the database load command.  
490  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4019E  
Load command: Load processing failed - insufficient database space.  
Explanation: The load process fails due to insufficient database space.  
System Action: Load processing ends.  
User Response: Reinstall the server and specify a larger database and reissue the  
database load command.  
ANR4020E  
Load command: Batch database insert failed.  
Explanation: The database load process fails when it attempts to insert a batch of  
rows into the database.  
System Action: Database load processing ends.  
User Response: Examine the messages issued prior to this one to determine if an  
error can be corrected. You may wish to reinstall the server with a new recovery log  
and database and reissue the load command. If the problem persists, contact your  
service representative.  
ANR4021E  
ANR4022E  
ANR4023E  
Dump/load command: Error (error code) occurred during an open operation.  
Explanation: An error occurs while attempting an open operation on the dump  
media for a database dump/load operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the  
operation failed; correct the problem and restart the process.  
Dump command: Error (error code) occurred during a write operation.  
Explanation: The server database dump process encounters an error while writing  
to the dump media.  
System Action: Server processing continues, the dump processing ends.  
User Response: Refer to the other displayed messages to determine why the  
operation failed; correct the problem and restart the process.  
Load command: Error (error code) occurred during a read operation.  
Explanation: The server database load process encounters an error reading from  
the dump media.  
System Action: The database load operation ends.  
User Response: Refer to the other displayed messages to determine why the  
operation failed; correct the problem and restart the process.  
Tivoli Storage Manager Messages  
491  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4025I  
Dumped number of pages database pages, number of bit vectors bit vectors, and  
number of database entries database entries; number of bad pages bad database  
pages have been encountered; number of bytes copied.  
Explanation: This message is displayed in response to a QUERY PROCESS  
command executed against an online database dump process. The message displays  
information about the progress of the dump.  
System Action: Database dump processing continues.  
User Response: None. You may cancel the dump process with the CANCEL  
PROCESS command.  
ANR4026I  
ANR4027I  
ANR4028I  
Dump command: Process process number, database dump has completed.  
Explanation: The online server database dump process started as process process  
number has completed.  
System Action: Database dump processing ends.  
User Response: None.  
Dump command: Process process number, database dump was canceled.  
Explanation: The online server database dump process started as process process  
number has been canceled with the CANCEL PROCESS command.  
System Action: Database dump processing ends.  
User Response: None.  
Dump command: Process process number, Database dump terminated due to an  
error (error code).  
Explanation: The online database dump process has ended prematurely due to an  
error.  
System Action: The server ends dump processing.  
User Response: Examine the messages issued prior to this message to see if an  
error can be corrected, such as output error. If you cannot resolve the error, contact  
your service representative.  
ANR4029I  
Dump command: Database checkpoint started.  
Explanation: The database dump process is flushing updated database pages from  
the database buffer pool to stable storage so that they can be dumped.  
System Action: Database dump processing continues.  
492  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4030I  
ANR4031I  
ANR4032I  
ANR4033I  
ANR4034I  
Dump command: Database checkpoint completed.  
Explanation: The database dump process has flushed all updated pages from the  
database buffer pool to stable storage.  
System Action: Database load processing continues.  
User Response: None.  
Dump/load command: Copied number of pages database pages.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of database pages copied.  
System Action: Database dump or load processing ends.  
User Response: None.  
Dump/load command: Copied number of records database records.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of database records copied.  
System Action: Database dump or load processing ends.  
User Response: None.  
Dump/load command: Copied number of bit vectors bit vectors.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of database bit vectors copied.  
System Action: Database dump or load processing ends.  
User Response: None.  
Dump/load command: Encountered number of bit vectors bad database pages.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of invalid database pages that have been  
encountered.  
System Action: Database dump or load processing ends.  
User Response: None.  
Tivoli Storage Manager Messages  
493  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4035I  
Dump/load command: Encountered number of bit vectors bad database records.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of invalid database records that have been  
encountered.  
System Action: Database dump or load processing ends.  
User Response: None.  
ANR4036I  
ANR4037I  
ANR4038I  
Dump/load command: Copied number of bit vectors database entries.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of database entries that have been copied.  
System Action: Database dump or load processing ends.  
User Response: None.  
Dump/load command: number of bit vectors copied.  
Explanation: This message is displayed at the end of a server database dump or  
load command to indicate the number of bytes that have been copied.  
System Action: Database dump or load processing ends.  
User Response: None.  
Load command: Loading database information dumped on dump date at dump  
time.  
Explanation: At the beginning of a server database load process, this message  
indicates the date and time that the dump took place for the database information  
that is loaded into the server.  
System Action: Database load processing continues.  
User Response: None.  
ANR4039I  
Load command: Loaded number of entries database entries (cumulative).  
Explanation: This message indicates the number of database entries that have  
been loaded so far during database load processing.  
System Action: Database load processing continues.  
User Response: None.  
494  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4040I  
Audit command: Auditing client node and administrator definitions.  
Explanation: This message is displayed during a database audit and indicates that  
the client node and administrator definitions are being examined by the database  
audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4041I  
Audit command: Node node name is assigned to Domain domain name, but not  
verified by server database policy entries.  
Explanation: A database audit process finds a node assigned to a policy domain  
that is not recorded properly in policy database entries.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the policy domain assignment for the node.  
ANR4042I  
Audit command: Node node name is assigned to Domain domain name, but not  
found in server database policy entries - attempting to assign the node to  
domain domain name.  
Explanation: A database audit process finds a node assigned to a policy domain  
that cannot be referenced in database policy entries. Because FIX=YES has been  
specified for the audit command, the audit function will attempt to correct the  
policy domain assignment for the node.  
System Action: Audit processing continues.  
User Response: When the audit command completes, you may want to check the  
domain assignment for this node, and reassign the node to a different policy  
domain, if desired.  
ANR4043I  
Audit command: Node node name assignment failed - will attempt to assign the  
node to domain domain name.  
Explanation: A database audit process finds a node assigned to a policy domain  
that cannot be located in database policy entries. Because FIX=YES has been  
specified for the audit command, the audit function is attempting to assign the node  
to an existing policy domain. The function attempts to assign the node to the  
domain name specified.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
495  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: When the audit command completes, you may want to check the  
domain assignment for this node, and reassign the node to a different policy  
domain, if desired.  
ANR4044I  
ANR4045I  
ANR4046I  
Audit command: Could not assign Node node name to a policy domain; use the  
UPDATE NODE command to assign a policy domain for this node.  
Explanation: A database audit process cannot find an appropriate policy domain  
for assigning the specified node.  
System Action: Audit processing continues.  
User Response: When the audit command completes, use the UPDATE NODE  
command to assign the specified node to an appropriate policy domain.  
Audit command: Invalid compression value encountered for node node name.  
Explanation: A database audit process encounters an invalid node compression  
value for the node indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
Audit command: Invalid compression value encountered for node node name the  
default value will be set.  
Explanation: A database audit process encounters an invalid node compression  
value for the node indicated. Because FIX=YES has been specified, the audit  
function sets the node’s compression value to the default value.  
System Action: Audit processing continues.  
User Response: If you want the compression value for the specified node to be set  
to a value other than the default, use the UPDATE NODE command to change the  
value after the audit command has completed.  
ANR4047I  
Audit command: Invalid archive delete value encountered for node node name.  
Explanation: A database audit process encounters an invalid archive delete  
permission value for the node indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
496  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4048I  
Audit command: Invalid archive delete value encountered for node node name  
the default value will be set.  
Explanation: A database audit process encounters an invalid archive delete  
permission value for the node indicated. Because FIX=YES has been specified, the  
audit function sets the node’s archive delete permission value to the default value.  
System Action: Audit processing continues.  
User Response: If you want the archive delete value for the specified node to be  
set to a value other than the default, use the UPDATE NODE command to change  
the value after the audit command has completed.  
ANR4049I  
Audit command: Invalid backup delete value encountered for node node name.  
Explanation: A database audit process encounters an invalid backup delete  
permission value for the node indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
ANR4050I  
Audit command: Invalid backup delete value encountered for node node name  
the default value will be set.  
Explanation: A database audit process encounters an invalid backup delete  
permission value for the node indicated. Because FIX=YES has been specified, the  
audit function sets the node’s backup delete permission value to the default value.  
System Action: Audit processing continues.  
User Response: If you want the backup delete value for the specified node to be  
set to a value other than the default, use the UPDATE NODE command to change  
the value after the audit command has completed.  
ANR4051I  
Audit command: Invalid lock state encountered for node node name.  
Explanation: A database audit process encounters an invalid lock state value for  
the node indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
Tivoli Storage Manager Messages  
497  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4052I  
Audit command: Invalid lock state encountered for node node name the node will  
be unlocked.  
Explanation: A database audit process encounters an invalid lock state value for  
the node indicated. Because FIX=YES has been specified, the audit function sets the  
node’s lock state to unlocked.  
System Action: Audit processing continues.  
User Response: If you want the lock state for the specified node to be set to a  
value other than unlocked, use the LOCK NODE command to change the value  
after the audit command has completed.  
ANR4053I  
ANR4054I  
ANR4055I  
Audit command: Invalid Node conversion state encountered for node node name.  
Explanation: A database audit process encounters an invalid Node conversion  
state value for the node indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem. However, next time this node logs onto the server,  
the node conversion state will be reset.  
Audit command: Invalid Node conversion state encountered for node node name  
the node will be set as an ADSM Version 2 node.  
Explanation: A database audit process encounters an invalid Node conversion  
state value for the node indicated. Because FIX=YES has been specified, the audit  
function sets the node as an ADSM version 2 node.  
System Action: Audit processing continues.  
User Response: The specified node must use the ADSM Version 2 client program  
to access the server after the audit completes.  
Audit command: Invalid lock state encountered for administrator administrator  
name.  
Explanation: A database audit process encounters an invalid lock state value for  
the administrator indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
498  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4056I  
Audit command: Invalid lock state encountered for administrator administrator  
name the administrator will be unlocked.  
Explanation: A database audit process encounters an invalid lock state value for  
the administrator indicated. Because FIX=YES has been specified, the audit function  
sets the administrator’s lock state to unlocked.  
System Action: Audit processing continues.  
User Response: If you want the lock state for the specified administrator to be set  
to a value other than unlocked, use the LOCK ADMIN command to change the  
value after the audit command has completed.  
ANR4057E  
Audit command: Administrative global attributes are missing.  
Explanation: A database audit process finds that the global attributes used for  
server administrative activities are missing.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES specified so that the  
administrative global attributes can be recreated.  
ANR4058I  
Audit command: Administrative global attributes are missing - default values  
will be used to recreate the attributes.  
Explanation: A database audit process finds that the global attributes used for  
server administrative activities are missing. Because FIX=YES has been specified  
on the AUDIT command, default attribute values will be used to recreate the  
administrative global attributes.  
System Action: Audit processing continues.  
User Response: When the audit completes, you can use the QUERY STATUS  
command to examine the values set for the administrative global attributes, and use  
the appropriate SET command to change the attributes, if desired.  
ANR4059E  
Audit command: Administrative ID assignments are incorrect.  
Explanation: A database audit process finds that the global attributes used for  
server administrative activities are incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES specified so that the  
administrative global attributes can be corrected.  
Tivoli Storage Manager Messages  
499  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4060I  
Audit command: Administrative ID assignments are incorrect - value(s) will be  
corrected.  
Explanation: A database audit process finds that the global attributes used for  
server administrative activities are incorrect. Because FIX=YES has been specified  
on the AUDIT command, the attribute value will be corrected in the server database.  
System Action: Audit processing continues.  
User Response: None.  
ANR4061E  
Audit command: Administrative global attribute(s) are incorrect.  
Explanation: A database audit process finds that the global attributes used for  
server administrative activities are incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES specified so that the  
administrative global attributes can be corrected.  
ANR4062I  
Audit command: Administrative global attribute(s) are incorrect - default values  
will be set.  
Explanation: A database audit process finds that the global attributes used for  
server administrative activities are incorrect. Because FIX=YES has been specified  
on the AUDIT command, default attribute values will be used to correct the  
administrative global attributes.  
System Action: Audit processing continues.  
User Response: When the audit completes, you can use the QUERY STATUS  
command to examine the values set for the administrative global attributes, and use  
the appropriate SET command to change the attributes, if desired.  
ANR4063E  
Audit command: Client node node number not found in the server database.  
Explanation: A database audit process finds a client node reference that is not  
defined correctly in the server database.  
System Action: Audit processing continues.  
User Response: If the audit command has not been issued with FIX=YES  
specified, reissue the audit function specifying FIX=YES so that the error can be  
corrected.  
500  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4064I  
Audit command: Client node node number created as node node name assigned to  
policy domain domain name in the server database.  
Explanation: A database audit process finds a client node reference that is not  
defined correctly in the server database. Because FIX=YES has been specified for  
the audit command, the audit function creates a new node definition for the node  
with the name specified.  
System Action: Audit processing continues.  
User Response: After the AUDIT command completes, use the QUERY NODE  
command to examine the node that was added. Use the RENAME NODE command  
to rename the corrected node and the UPDATE NODE command to set attributes  
for the corrected node, such as its password. You can issue the QUERY  
FILESPACE command for the node, to determine which node and platform type  
was originally represented by the corrected node.  
ANR4065E  
Audit command: Administrator administrator number not found in the server  
database.  
Explanation: A database audit process finds an administrator reference that is not  
defined correctly in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4066I  
Audit command: Administrator administrator number not found in the server  
database - reference will be removed.  
Explanation: A database audit process finds an administrator reference that is not  
defined correctly in the server database. The invalid reference will be removed from  
the database.  
System Action: Audit processing continues.  
User Response: After the audit command completes, review your administrator  
definitions with the QUERY ADMIN command. You can then use the REGISTER  
ADMIN and UPDATE ADMIN commands to change any definitions desired.  
ANR4067E  
Audit command: Domain domain name referenced by an administrator authority  
does not exist.  
Explanation: A database audit process finds a policy administrator reference to a  
policy domain that does not exist.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
501  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4068I  
Audit command: Policy domain domain name referenced by an administrator  
authority does not exist - the authority will be removed.  
Explanation: A database audit process finds a policy administrator reference to a  
policy domain that does not exist. Because FIX=YES has been specified, the  
authority will be removed.  
System Action: Audit processing continues.  
User Response: After the audit command completes, review your administrator  
definitions with the QUERY ADMIN command. You can then use the REGISTER  
ADMIN, UPDATE ADMIN, and GRANT AUTHORITY commands to change any  
definitions.  
ANR4069E  
Audit command: Storage pool storage pool name referenced by an administrator  
authority does not exist.  
Explanation: A database audit process finds a storage administrator reference to a  
storage pool that does not exist.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4070I  
Audit command: Storage pool storage pool name referenced by an administrator  
authority does not exist - the authority will be removed.  
Explanation: A database audit process finds a policy administrator reference to a  
storage pool that does not exist. Because FIX=YES has been specified, the authority  
will be removed.  
System Action: Audit processing continues.  
User Response: After the audit command completes, review your administrator  
definitions with the QUERY ADMIN command. You can then use the REGISTER  
ADMIN, UPDATE ADMIN, and GRANT AUTHORITY commands to change any  
definitions.  
ANR4071I  
Audit command: Invalid sign-on attempts is not valid for node/administrator  
name.  
Explanation: A database audit process encounters an invalid sign-on attempts  
value that is not valid for the node or administrator indicated.  
System Action: Audit processing continues.  
502  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
ANR4072I  
Audit command: Invalid file aggregation information encountered for node node  
name.  
Explanation: A database audit process encounters invalid information used for  
controlling aggregation of files for the node indicated.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command, you  
may want to run this command again, and specify FIX=YES so that the audit  
process can correct the problem.  
ANR4073I  
Audit command: Invalid file aggregation information encountered for node node  
name - information will be corrected.  
Explanation: A database audit process encounters invalid information used for  
controlling aggregation of files for the node specified. Because FIX=YES has been  
specified, the audit function corrects the information.  
System Action: Audit processing continues.  
User Response: None.  
ANR4075I  
Audit command: Auditing policy definitions.  
Explanation: This message is displayed during a database audit and indicates that  
the server policy information (domain, policy set, management classes, and copy  
groups) are being examined by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4076E  
Audit command: Invalid client node count detected for policy domain domain  
name.  
Explanation: A database audit process finds that the count of nodes recorded for  
the specified policy domain do not match the actual number of nodes assigned to  
the domain.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
503  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4077I  
Audit command: Invalid client node count detected for policy domain domain  
name count will be corrected.  
Explanation: A database audit process finds that the count of nodes recorded for  
the specified policy domain do not match the actual number of nodes assigned to  
the domain. Because FIX=YES has been specified for the command, the node count  
will automatically be corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4078E  
ANR4079I  
ANR4080E  
Audit command: Invalid activation indicators encountered for policy domain  
domain name.  
Explanation: A database audit process finds incorrect policy set activation entries  
for the specified policy domain.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid activation indicators encountered for policy domain  
domain name - entry will be corrected.  
Explanation: A database audit process finds incorrect policy set activation entries  
for the specified policy domain. Because FIX=YES has been specified for the audit  
command, the entry will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Invalid grace period backup retention value encountered for  
policy domain domain name.  
Explanation: A database audit process finds an incorrect grace period retention  
value for the specified policy domain.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
504  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4081I  
ANR4082E  
ANR4083I  
ANR4084E  
Audit command: Invalid grace period backup retention value encountered for  
policy domain domain name - default value will be set.  
Explanation: A database audit process finds an incorrect grace period retention  
value for the specified policy domain. Because FIX=YES has been specified for the  
audit command, the default value will be set.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Invalid grace period archive retention value encountered for  
policy domain domain name.  
Explanation: A database audit process finds an incorrect grace period retention  
value for the specified policy domain.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid grace period archive retention value encountered for  
policy domain domain name - default value will be set.  
Explanation: A database audit process finds an incorrect grace period retention  
value for the specified policy domain. Because FIX=YES has been specified for the  
audit command, the default value will be set.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Invalid administrator update information encountered for  
policy domain domain name.  
Explanation: A database audit process finds incorrect last updated information for  
the specified policy domain.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
505  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4085I  
ANR4086E  
ANR4087I  
ANR4088E  
Audit command: Invalid administrator update information encountered for  
policy domain domain name - information will be corrected.  
Explanation: A database audit process finds incorrect last updated information for  
the specified policy domain. Because FIX=YES has been specified for the  
command, the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Invalid node node number found assigned to domain domain  
name.  
Explanation: A database audit process finds a node number assigned to a policy  
domain that does not reference a valid client node definition.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid node node number found assigned to domain domain  
name reference will be deleted.  
Explanation: A database audit process finds a node number assigned to a policy  
domain that does not reference a valid client node definition. Because FIX=YES has  
been specified for the audit command, the reference will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Default management class management class name specified for  
policy set policy set name in domain domain name does not exist.  
Explanation: A database audit process finds a policy set with a default  
management class specified that does not exist.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
506  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4089I  
Audit command: Default management class management class name specified for  
policy set policy set name in domain domain name does not exist - the reference  
will be removed.  
Explanation: A database audit process finds a policy set with a default  
management class specified that does not exist. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the policy set.  
System Action: Audit processing continues.  
User Response: When the audit command completes, examine the policy set  
specified, and set a new default management class for the set. If the policy set is the  
ACTIVE policy set, you must activate a new policy set for the domain with a valid  
default management class.  
ANR4090E  
Audit command: Active Policy set for domain domain name does not contain a  
valid default management class - policy will fail for this domain. Please correct  
the ACTIVE policy set.  
Explanation: A database audit process finds an active policy set for the specified  
policy domain that does not have a valid active management class specified.  
System Action: Audit processing continues.  
User Response: When the audit command completes, you must activate a new  
policy set for the domain with a valid default management class.  
ANR4091E  
Audit command: Invalid administrator update information encountered for  
policy set set name in policy domain domain name.  
Explanation: A database audit process finds incorrect last updated information for  
the specified policy set.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4092I  
Audit command: Invalid administrator update information encountered for  
policy set set name in policy domain domain name - information will be  
corrected.  
Explanation: A database audit process finds incorrect last updated information for  
the specified policy set. Because FIX=YES has been specified for the command, the  
information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
507  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4093E  
Audit command: A management class identifier is not defined for management  
class management class name in policy set set name, domain domain name.  
Explanation: A database audit process finds incorrect information for the specified  
management class.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4094E  
Audit command: A management class identifier is not defined for management  
class management class name in policy set set name, domain domain name - an  
identifier will be generated for this management class.  
Explanation: A database audit process finds incorrect information for the specified  
management class. The audit process generates an identifier, because FIX=YES has  
been specified for the audit command.  
System Action: Audit processing continues.  
User Response: None.  
ANR4095E  
Audit command: An invalid management class identifier (actual identifier) was  
encountered for management class management class name in policy set set  
name, domain domain name (expected expected identifier).  
Explanation: A database audit process finds incorrect information for the specified  
management class.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4096E  
Audit command: An invalid management class identifier (actual identifier) was  
encountered for management class management class name in policy set set  
name, domain domain name (expected expected identifier) - the correct identifier  
will be stored.  
Explanation: A database audit process finds incorrect information for the specified  
management class. The audit process corrects the identifier, because FIX=YES has  
been specified for the audit command.  
System Action: Audit processing continues.  
User Response: None.  
508  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4097E  
ANR4098I  
ANR4099E  
ANR4100I  
Audit command: Invalid administrator update information encountered for  
management class management class name in policy set set name in policy  
domain domain name.  
Explanation: A database audit process finds incorrect last updated information for  
the specified management class.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid administrator update information encountered for  
management class management class name in policy set set name in policy  
domain domain name - information will be corrected.  
Explanation: A database audit process finds incorrect last updated information for  
the specified management class. Because FIX=YES has been specified for the  
command, the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Copy group copy group name in management class management  
class name, policy set set name, domain domain name has an invalid name or  
type.  
Explanation: A database audit process encounters a copy group that has an invalid  
name or copy group type.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command,  
reissue the command specifying FIX=YES so that the error can be corrected.  
Audit command: Attempting to reinsert the copy group as a BACKUP copy  
group.  
Explanation: A database audit process encounters a copy group that has an invalid  
name or copy group type. The process attempts to reinsert the definition as a backup  
copy group.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
509  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4101I  
Audit command: A backup copy group already exists - the invalid copy group  
will be deleted.  
Explanation: A database audit process encounters a copy group that has an invalid  
name or copy group type. While attempting to reinsert the copy group as a backup  
copy group, the process discovers that a backup copy group already exists for the  
management class. The copy group is deleted.  
System Action: Audit processing continues.  
User Response: After the audit command completes, you may examine the server  
copy groups using the QUERY COPYGROUP command, and correct them with the  
DEFINE COPYGROUP and UPDATE COPYGROUP commands if desired.  
ANR4102I  
Audit command: Attempting to reinsert the copy group as an ARCHIVE copy  
group.  
Explanation: A database audit process encounters a copy group that has an invalid  
name or copy group type. The process attempts to reinsert the definition as an  
archive copy group.  
System Action: Audit processing continues.  
User Response: None.  
ANR4103I  
Audit command: An archive copy group already exists - the invalid copy group  
will be deleted.  
Explanation: A database audit process encounters a copy group that has an invalid  
name or copy group type. While attempting to reinsert the copy group as an archive  
copy group, the process discovers that a backup copy group already exists for the  
management class. The copy group is deleted.  
System Action: Audit processing continues.  
User Response: After the audit command completes, you may examine the server  
copy groups using the QUERY COPYGROUP command, and correct them with the  
DEFINE COPYGROUP and UPDATE COPYGROUP commands, if desired.  
ANR4104E  
Audit command: An invalid management class identifier (actual identifier) was  
encountered for a copy group in management class management class name,  
policy set set name, domain domain name (expected expected identifier).  
Explanation: A database audit process finds incorrect information for the specified  
copy group.  
System Action: Audit processing continues.  
510  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4105E  
Audit command: An invalid management class identifier (actual identifier) was  
encountered for a copy group in management class management class name,  
policy set set name, domain domain name (expected expected identifier) - the  
correct identifier will be stored.  
Explanation: A database audit process finds incorrect information for the specified  
copy group. The audit process corrects the identifier, since FIX=YES has been  
specified for the audit command.  
System Action: Audit processing continues.  
User Response: None.  
ANR4106E  
ANR4107E  
ANR4108E  
Audit command: An invalid copy group identifier (actual identifier) was  
encountered for a copy group in management class management class name,  
policy set set name, domain domain name (expected expected identifier).  
Explanation: A database audit process finds incorrect information for the specified  
copy group.  
System Action: Audit processing continues.  
User Response: For programming support, contact your service representative.  
Audit command: An invalid copy group identifier (actual identifier) was  
encountered for copy group name copy group name (expected expected  
identifier).  
Explanation: A database audit process finds incorrect information for the specified  
copy group name.  
System Action: Audit processing continues.  
User Response: For programming support, contact your service representative.  
Audit command: Invalid backup copy group attributes encountered for copy  
group copy group name in management class management class name, policy set  
set name, domain domain name.  
Explanation: A database audit process encounters invalid backup copy group  
attributes for the specified copy group.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
511  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If FIX=YES has not been specified for the audit command,  
reissue the command specifying FIX=YES so that the inconsistency can be  
corrected.  
ANR4109I  
Audit command: Invalid backup copy group attributes encountered for copy  
group copy group name in management class management class name, policy set  
set name, domain domain name - the copy group will be corrected using default  
attributes.  
Explanation: A database audit process encounters invalid backup copy group  
attributes for the specified copy group. Because FIX=YES has been specified for the  
command, the copy group will be corrected using default values for the attributes  
found in error.  
System Action: Audit processing continues.  
User Response: After the audit command completes, examine the copy group by  
using the QUERY COPYGROUP command, and correct attributes with the  
UPDATE COPYGROUP command, if desired.  
ANR4110E  
Audit command: Invalid archive copy group attributes encountered for copy  
group copy group name in management class management class name, policy set  
set name, domain domain name.  
Explanation: A database audit process encounters invalid archive copy group  
attributes for the specified copy group.  
System Action: Audit processing continues.  
User Response: If FIX=YES has not been specified for the audit command,  
reissue the command and specify FIX=YES so that the inconsistency can be  
corrected.  
ANR4111I  
Audit command: Invalid archive copy group attributes encountered for copy  
group copy group name in management class management class name, policy set  
set name, domain domain name - the copy group will be corrected using default  
attributes.  
Explanation: A database audit process encounters invalid archive copy group  
attributes for the specified copy group. Because FIX=YES has been specified for the  
command, the copy group will be corrected using default values for the attributes  
found in error.  
System Action: Audit processing continues.  
User Response: After the audit command completes, examine the copy group by  
using the QUERY COPYGROUP command, and correct the attributes with the  
UPDATE COPYGROUP command, if desired.  
512  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4112W  
Audit command: Storage pool storage pool name, specified as a destination for  
copy group copy group name in management class management class name,  
policy set set name, domain domain name, does not exists.  
Explanation: A database audit process encounters a storage pool specified for the  
destination of the specified copy group that is not defined in the server database. If  
this copy group is used in an active policy set, then backup or archive operations  
will fail when attempting to put client data in the destination.  
System Action: Audit processing continues.  
User Response: After the audit command completes, use the DEFINE STGPOOL  
command to define the missing storage pool or the UPDATE COPYGROUP  
command to update the copy group to refer to an existing storage pool.  
ANR4113E  
ANR4114I  
ANR4115E  
Audit command: Invalid administrator update information encountered for copy  
group copy group name in management class management class name, policy set  
set name, policy domain domain name.  
Explanation: A database audit process finds incorrect last updated information for  
the specified copy group.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid administrator update information encountered for copy  
group copy group name in management class management class name, policy set  
set name, policy domain domain name - information will be corrected.  
Explanation: A database audit process finds incorrect last updated information for  
the specified copy group. Because FIX=YES has been specified for the command,  
the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Policy domain domain name is referenced, but not formally  
defined.  
Explanation: A database audit process finds a reference to the specified policy  
domain, but the domain is not formally defined in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
513  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4116I  
Audit command: Policy domain domain name is referenced, but not formally  
defined - a policy domain with default attributes will be defined with this  
name.  
Explanation: A database audit process finds a reference to the specified policy  
domain, but the domain is not formally defined in the server database. Because  
FIX=YES has been specified, a new policy domain with this name will be defined  
by the audit processor.  
System Action: Audit processing continues.  
User Response: After the audit command has completed, you can view the  
attributes for this policy domain using the QUERY DOMAIN command, and update  
attributes with the UPDATE DOMAIN command, if desired.  
ANR4117E  
Audit command: Policy set set name in domain domain name is referenced, but  
not formally defined.  
Explanation: A database audit process finds a reference to the specified policy set,  
but the set is not formally defined in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4118I  
Audit command: Policy set set name in domain domain name is referenced, but  
not formally defined - a policy set with this name will be created.  
Explanation: A database audit process finds a reference to the specified policy set,  
but the set is not formally defined in the server database. Because FIX=YES has  
been specified, the audit process will create a new policy set with this name.  
System Action: Audit processing continues.  
User Response: After the audit command has completed, you can view the  
attributes for this policy set by using the QUERY POLICYSET command, and  
update attributes with the UPDATE POLICYSET command, if desired.  
ANR4119E  
Audit command: Management class class name in policy set set name, domain  
domain name is referenced, but not formally defined.  
Explanation: A database audit process finds a reference to the specified  
management class, but the class is not formally defined in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
514  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4120I  
Audit command: Management class class name in policy set set name, domain  
domain name is referenced, but not formally defined - the management class  
will be created.  
Explanation: A database audit process finds a reference to the specified  
management class, but the class is not formally defined in the server database.  
Because FIX=YES has been specified for the audit command, the audit process  
defines a management class in the server with this name.  
System Action: Audit processing continues.  
User Response: After the audit command has completed, you can view the  
attributes for this management class by using the QUERY MGMTCLASS command,  
and update attributes with the UPDATE MGMTCLASS command, if desired.  
ANR4122E  
Audit command: The instance count for management class class name does not  
agree with the actual management class data (number of instances instances).  
Explanation: A database audit process finds a reference count for the specified  
management class that did not match the actual number of instances for this class.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4123I  
Audit command: The instance count for management class class name does not  
agree with the actual management class data (number of instances instances) -  
the number will be corrected.  
Explanation: A database audit process finds a reference count for the specified  
management class that does not match the actual number of instances for this class.  
The audit process corrects the count because FIX=YES has been specified for the  
audit command.  
System Action: Audit processing continues.  
User Response: None.  
ANR4124E  
Audit command: The instance count for copy group copy group name does not  
agree with the actual copy group data (number of instances instances).  
Explanation: A database audit process finds a reference count for the specified  
copy group that does not match the actual number of instances for this copy group.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
515  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4125I  
Audit command: The instance count for copy group copy group name does not  
agree with the actual copy group data (number of instances instances) - the  
number will be corrected.  
Explanation: A database audit process finds a reference count for the specified  
copy group that does not match the actual number of instances for this copy group.  
The audit process corrects the count because FIX=YES has been specified for the  
audit command.  
System Action: Audit processing continues.  
User Response: None.  
ANR4126E  
Audit command: Policy global attributes cannot be found.  
Explanation: A database audit process is not able to locate the global attributes for  
policy information in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4127I  
Audit command: Policy global attributes cannot be found - attributes will  
recreated.  
Explanation: A database audit process is not able to locate the global attributes for  
policy information in the server database. Because FIX=YES has been specified for  
the audit command, the attributes will be regenerated.  
System Action: Audit processing continues.  
User Response: None.  
ANR4128E  
Audit command: Policy global high-water marks do not match the identifiers in  
use.  
Explanation: A database audit process finds the attributes used to track policy  
identifiers are incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
516  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4129E  
ANR4130W  
ANR4131W  
ANR4132I  
Audit command: Policy global high-water marks do not match the identifiers in  
use - they will be corrected.  
Explanation: A database audit process finds the attributes used to track policy  
identifiers are incorrect. Because FIX=YES has been specified for the audit  
command, the attributes will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit Volume updating object information for volume volume name: Node node  
name, Type file type, File space filespace name, File Name file name.  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=YES for the volume shown, object information for the specified file will be  
updated.  
System Action: The object information is updated.  
User Response: None.  
Audit Volume found incorrect object information for volume volume name:  
Node node name, Type file type, File space filespace name, File name file name.  
Explanation: As the result of an AUDIT VOLUME command that specified  
FIX=NO for the volume shown, object information for the specified file is found to  
be in error.  
System Action: None.  
User Response: None.  
Audit volume process ended for volume volume name; file count files inspected,  
file count damaged files deleted, file count damaged files marked as damaged,  
file count objects updated.  
Explanation: The AUDIT VOLUME command specifying FIX=YES for the  
volume shown has ended. The number of files audited, the number of inconsistent  
files deleted or marked as damaged, and the number of updated objects are  
displayed. The number of files marked as damaged includes all files belonging to  
aggregates that were marked damaged during the audit. Files are marked as  
damaged in primary storage pools and not deleted when backup copies for the files  
are known to exist in COPY storage pools.  
System Action: None.  
User Response: To recover files that have been marked as damaged on the  
volume, use the RESTORE STGPOOL or RESTORE volume command.  
Tivoli Storage Manager Messages  
517  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4133I  
Audit volume process ended for volume volume name; file count files inspected,  
file count damaged files found and marked as damaged, file count objects need  
updating.  
Explanation: The AUDIT VOLUME command specifying FIX=NO for the  
volume shown has ended. The number of files audited, the number of inconsistent  
files found, and the number of files with incorrect object information are displayed.  
The number of files marked damaged includes all files belonging to aggregates that  
were marked damaged during the audit. Inconsistent files are marked as damaged in  
the database and can be recovered by using the RESTORE STGPOOL or  
RESTORE VOLUME command if copies of the files reside in a COPY storage  
pool. Another AUDIT VOLUME command may be able to access the files and reset  
the damaged indicator in the database if the audit volume process cannot access the  
files due to hardware problems (for example, dirty tape heads).  
System Action: None.  
User Response: If you suspect that files were inaccessible because of hardware  
problems such as dirty tape heads, correct the hardware problem and reissue the  
AUDIT VOLUME FIX=NO command for this volume. To remove damaged file  
references and update the object information, issue the AUDIT VOLUME command  
and specify FIX=YES.  
ANR4135I  
Audit command: Auditing central scheduler definitions.  
Explanation: This message is displayed during a database audit and indicates that  
the server scheduling information is examined by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4136I  
Audit command: Auditing server inventory.  
Explanation: This message is displayed during a database audit and indicates that  
server information about client file spaces is currently being examined by the  
database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4137I  
Audit command: Auditing inventory file spaces.  
Explanation: This message is displayed during a database audit and indicates that  
server information about client file spaces is currently being examined by the  
database audit process.  
System Action: Audit processing continues.  
518  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4138I  
Audit command: Auditing inventory backup objects.  
Explanation: This message is displayed during a database audit and indicates that  
server information about client backup objects is currently being examined by the  
database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4139I  
Audit command: Auditing inventory archive objects.  
Explanation: This message is displayed during a database audit and indicates that  
server information about client archive objects is currently being examined by the  
database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4140I  
ANR4141I  
ANR4142I  
Audit command: Database audit process started.  
Explanation: This message is displayed during a database audit and indicates that  
the audit process has started.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Database audit process completed.  
Explanation: This message is displayed during a database audit and indicates that  
the database audit has successfully completed.  
System Action: Audit processing ends.  
User Response: None.  
Audit command: Database audit process terminated in error.  
Explanation: This message is displayed during a database audit and indicates that  
the audit process ended prematurely due to an internal server database error.  
System Action: Audit processing ends.  
User Response: Examine the messages issued prior to this one to see if the error  
can be corrected. If the situation cannot be resolved, contact your service  
representative.  
Tivoli Storage Manager Messages  
519  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4143E  
Audit command: Central scheduler global attributes cannot be found.  
Explanation: A database audit process cannot locate the global attributes for  
scheduling information in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4144I  
Audit command: Central scheduler global attributes cannot be found - attributes  
will be recreated.  
Explanation: A database audit process cannot locate the global attributes for  
scheduler information in the server database. Because FIX=YES has been specified  
for the audit command, the attributes will be regenerated.  
System Action: Audit processing continues.  
User Response: None.  
ANR4145E  
Audit command: One or more central scheduler attributes are incorrect.  
Explanation: A database audit process finds that the global attributes used for  
server scheduling activities are incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
administrative global attributes can be corrected.  
ANR4146I  
Audit command: One or more central scheduler global attribute(s) are incorrect  
- default values will be set.  
Explanation: A database audit process finds that the global attributes used for  
server scheduling activities are incorrect. Because FIX=YES has been specified on  
the AUDIT command, default attribute values will be used to correct the scheduling  
global attributes.  
System Action: Audit processing continues.  
User Response: When the audit completes, you can use the QUERY STATUS  
command to examine the values set for the administrative global attributes, and use  
the appropriate SET command to change the attributes, if desired.  
520  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4147E  
Audit command: Policy domain domain name referenced by schedule schedule  
name does not exist.  
Explanation: A database audit process finds a schedule that references a policy  
domain that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
administrative global attributes can be corrected.  
ANR4148I  
Audit command: Policy domain domain name referenced by schedule schedule  
name does not exist - the schedule will be deleted.  
Explanation: A database audit process finds a schedule that references a policy  
domain that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the specified schedule will be deleted from the  
server database.  
System Action: Audit processing continues.  
User Response: None.  
ANR4149E  
Audit command: One or more attributes for schedule schedule name in policy  
domain domain name are incorrect.  
Explanation: A database audit process finds one or more invalid attributes for the  
specified schedule.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
administrative global attributes can be corrected.  
ANR4150I  
Audit command: One or more attributes for schedule schedule name in policy  
domain domain name are incorrect - default values will be set.  
Explanation: A database audit process finds one or more invalid attributes for the  
specified schedule. Because FIX=YES has been specified for the audit command the  
invalid attributes will be set to default values.  
System Action: Audit processing continues.  
User Response: When the audit completes, you can use the QUERY SCHEDULE  
command to examine the values set for the schedule, and use the UPDATE  
SCHEDULE command to change any attributes desired.  
Tivoli Storage Manager Messages  
521  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4151E  
Audit command: Schedule schedule name in policy domain domain name not  
found, but is referenced by a client node.  
Explanation: A database audit process finds a schedule reference from a client  
node for a schedule that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
administrative global attributes can be corrected.  
ANR4152I  
Audit command: Schedule schedule name in policy domain domain name not  
found, but is referenced by a client node - the schedule association will be  
deleted.  
Explanation: A database audit process finds a schedule reference from a client  
node for a schedule that is not defined in the server database. Because FIX=YES  
has been specified for the audit command, the schedule association will be deleted  
from the server database.  
System Action: Audit processing continues.  
User Response: None.  
ANR4153E  
Audit command: Schedule schedule name in policy domain domain name  
references a client node that does not exist.  
Explanation: A database audit process finds a schedule that references a client  
node that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
administrative global attributes can be corrected.  
ANR4154I  
Audit command: Schedule schedule name in policy domain domain name  
references a client node that does not exist - the node reference will be deleted.  
Explanation: A database audit process finds a schedule that references a client  
node that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
522  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4155E  
ANR4156I  
ANR4157E  
ANR4158I  
Audit command: Invalid administrator update information encountered for a  
schedule assignment.  
Explanation: A database audit process finds incorrect last updated information for  
a schedule-node assignment.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid administrator update information encountered for a  
schedule assignment - information will be corrected.  
Explanation: A database audit process finds incorrect last updated information for  
a schedule-node assignment. Because FIX=YES has been specified for the  
command, the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Scheduling callback address is registered for a client node that  
does not exist.  
Explanation: A database audit process finds a server-prompted-scheduling callback  
address for a node that does not exist.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Scheduling callback address is registered for a client node that  
does not exist - callback information will be deleted.  
Explanation: A database audit process finds a server-prompted-scheduling callback  
address for a node that does not exist. Because FIX=YES has been specified for the  
command, the callback information will be deleted from the server database.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
523  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4159I  
ANR4160I  
ANR4161I  
Audit command: An inventory authorization rule specifies an invalid node (node  
ID) or file space (filespace ID) - the rule will be deleted.  
Explanation: A database audit process finds that either a node ID or file space ID  
is invalid for an authorization rule. Since FIX=YES has been specified, the invalid  
authorization rule will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: An inventory authorization rule specifies an invalid node (node  
ID) or file space (filespace ID).  
Explanation: A database audit process finds that either a node ID or file space ID  
is invalid for an authorization rule.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Inventory global attributes could not be found - they will be  
created.  
Explanation: A database audit process cannot find the inventory global attributes.  
Because FIX=YES has been specified for the command, the information is corrected  
by the creation of the global attributes.  
System Action: Audit processing continues.  
User Response: None.  
ANR4162I  
Audit command: Inventory global attributes could not be found.  
Explanation: A database audit process cannot find the inventory global attributes.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4163I  
Audit command: Invalid object ID high-water mark encountered for inventory  
global attributes - the value will be corrected.  
Explanation: A database audit process finds that the object ID high-water mark  
for the inventory global attributes is invalid. Because FIX=YES has been specified  
for the command, the object ID high-water mark is determined by the current  
inventory and set accordingly.  
524  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Audit processing continues.  
User Response: None.  
ANR4164I  
ANR4165I  
ANR4166I  
ANR4167I  
Audit command: Invalid object ID high-water mark encountered for inventory  
global attributes.  
Explanation: A database audit process finds that the object ID high-water mark  
for the inventory global attributes is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: An inventory node assignment entry was not found for node  
node ID - an entry will be created.  
Explanation: A database audit process cannot find the node assignment entry  
corresponding to the specified node. Since FIX=YES has been specified for the  
command, the required inventory entry will be created using default values.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: An inventory node assignment entry was not found for node  
node ID.  
Explanation: A database audit process cannot find the node assignment entry  
corresponding to the specified node.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: The file space high-water mark for node node ID is incorrect -  
the value will be corrected.  
Explanation: A database audit process finds that a file space high-water mark is  
incorrect for the specified node ID. Since FIX=YES has been specified for the  
command, the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
525  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4168I  
Audit command: The file space high-water mark for node node ID is incorrect.  
Explanation: A database audit process finds that a file space high-water mark is  
incorrect for the specified node ID.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4169I  
Audit command: The file space high-water mark for node node ID is incorrect -  
the value will be corrected.  
Explanation: A database audit process finds that an authorization rule high-water  
mark is incorrect for the specified node ID. Since FIX=YES has been specified for  
the command, the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4170I  
ANR4171I  
ANR4172I  
Audit command: The authorization rule high-water mark for node node ID is  
incorrect.  
Explanation: A database audit process finds that an authorization rule high-water  
mark is incorrect for the specified node ID.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Primary backup entry for an expiring object (object.ID) cannot  
be found - the expiring object entry will be deleted.  
Explanation: A database audit process cannot find the primary backup entry for  
the specified expiring object. Because FIX=YES has been specified for the  
command, the information is corrected by deleting the expiring object entry.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Primary backup entry for an expiring object (object.ID) cannot  
be found.  
Explanation: A database audit process cannot find the primary backup entry for  
the specified expiring object.  
System Action: Audit processing continues.  
526  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4173I  
ANR4174I  
ANR4175I  
Audit command: Primary archive entry for an expiring object (object.ID) cannot  
be found - the expiring object entry will be deleted.  
Explanation: A database audit process cannot find the primary archive entry for  
the specified expiring object. Because FIX=YES has been specified for the  
command, the information is corrected by deleting the expiring object entry.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Primary archive entry for an expiring object (object.ID) cannot  
be found.  
Explanation: A database audit process cannot find the primary archive entry for  
the specified expiring object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid copy type encountered for an expiring objects entry  
(object.ID) - the expiring object entry will be deleted.  
Explanation: A database audit process finds that the copy type for the specified  
expiring object is invalid. Because FIX=YES has been specified for the command,  
the information is corrected by deleting the expiring object entry. The entry will be  
recreated later if it is necessary.  
System Action: Audit processing continues.  
User Response: None.  
ANR4176I  
Audit command: Invalid copy type encountered for an expiring objects entry  
(object.ID).  
Explanation: A database audit process finds that the copy type for the specified  
expiring object is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
527  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4177I  
Audit command: Primary backup entry for an object (object.ID) cannot be found  
- entry will be deleted.  
Explanation: A database audit process cannot find the specified primary backup  
object. Because FIX=YES has been specified for the command, the entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4178I  
Audit command: Primary backup entry for an object (object.ID) cannot be  
found.  
Explanation: A database audit process cannot find the specified primary backup  
object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4179I  
Audit command: Primary archive entry for an object (object.ID) cannot be found  
- entry will be deleted.  
Explanation: A database audit process cannot find the specified primary archive  
object. Because FIX=YES has been specified for the command, the entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4180I  
Audit command: Primary archive entry for an object (object.ID) cannot be  
found.  
Explanation: A database audit process cannot find the specified primary archive  
object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4181I  
Audit command: Invalid copy type encountered for object object.ID - object  
found as a backup object - correcting the invalid copy type  
Explanation: A database audit process encounters an invalid copy type for the  
specified object ID but finds a corresponding backup object for the entry. Because  
FIX=YES has been specified for the command, the invalid copy type is corrected.  
System Action: Audit processing continues.  
528  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4182I  
Audit command: Invalid copy type encountered for object object.ID - object  
found as an archive object - correcting the invalid copy type  
Explanation: A database audit process encounters an invalid copy type for the  
specified object ID but finds a corresponding archive object for the entry. Because  
FIX=YES has been specified for the command, the invalid copy type is corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4183I  
Audit command: Invalid copy type encountered for object object.ID - primary  
archive entry created for object using default values.  
Explanation: A database audit process encounters an invalid copy type for the  
specified object ID and is unable to find corresponding primary backup or primary  
archive objects. Because FIX=YES has been specified for the command, a primary  
archive entry is created using default values.  
System Action: Audit processing continues.  
User Response: None.  
ANR4184I  
Audit command: Invalid copy type encountered for object object.ID.  
Explanation: A database audit process encounters an invalid copy type for the  
specified object ID and is unable to find corresponding primary backup or primary  
archive objects.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4185I  
Audit command: Object entry for backup object object.ID not found - entry will  
be created.  
Explanation: A database audit process cannot find an object entry for the specified  
backup object. Because FIX=YES has been specified for the command, an object  
entry is created using default values.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
529  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4186I  
Audit command: Object entry for backup object object.ID not found.  
Explanation: A database audit process cannot find an object entry for the specified  
backup object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4187I  
Audit command: Inventory object fields for object object.ID do not match the  
primary backup entry - the object will be updated.  
Explanation: A database audit process determines that the object fields for the  
specified object ID do not match the fields for the corresponding primary backup  
object. Because FIX=YES has specified for the command, the incorrect object fields  
will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4188I  
Audit command: Inventory object fields for object object.ID do not match the  
primary backup entry.  
Explanation: A database audit process determines that the object fields for the  
specified object ID do not match the fields for the corresponding primary backup  
object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4189I  
Audit command: Expiring entry for inactive backup object object.ID not found -  
the entry will be created.  
Explanation: A database audit process cannot find an expiring entry for the  
specified inactive backup entry. Because FIX=YES has been specified for the  
command, an expiring entry will be created.  
System Action: Audit processing continues.  
User Response: None.  
ANR4190I  
Audit command: Expiring entry for inactive backup object object.ID not found.  
Explanation: A database audit process cannot find an expiring entry for the  
specified inactive backup entry.  
530  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4191I  
Audit command: Object entry for archive object object.ID not found - entry will  
be created.  
Explanation: A database audit process cannot find an object entry for the specified  
archive object. Because FIX=YES has been specified for the command, the  
information is corrected by creating an object entry.  
System Action: Audit processing continues.  
User Response: None.  
ANR4192I  
Audit command: Object entry for archive object object.ID not found.  
Explanation: A database audit process cannot find an object entry for the specified  
archive object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4193I  
Audit command: Inventory object fields for object object.ID do not match the  
primary archive entry - the object will be updated.  
Explanation: A database audit process determines that the object fields for the  
specified object ID do not match the fields for the corresponding primary archive  
object. Because FIX=YES has been specified for the command, the incorrect object  
fields will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4194I  
Audit command: Inventory object fields for object object.ID do not match the  
primary archive entry.  
Explanation: A database audit process determines that the object fields for the  
specified object ID do not match the fields for the corresponding primary archive  
object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
531  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4195I  
Audit command: Expiring entry for archive object object.ID not found - the  
entry will be created.  
Explanation: A database audit process cannot find an expiring entry for the  
specified archive object. Because FIX=YES has been specified for the command, an  
expiring entry will be created.  
System Action: Audit processing continues.  
User Response: None.  
ANR4196I  
ANR4197I  
ANR4198I  
Audit command: Expiring entry for archive object object.ID not found.  
Explanation: A database audit process cannot find an expiring entry for the  
specified archive object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: File space entry filespace ID not found for node node ID.  
Explanation: A database audit process cannot find a file space entry for the  
specified node.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: File space entry filespace ID not found for node node name - an  
entry will be created.  
Explanation: A database audit process cannot find a file space entry for the  
specified node. Because FIX=YES has been specified for the command, a file space  
entry has been created.  
System Action: Audit processing continues.  
User Response: None.  
ANR4199I  
Audit command: File space entry filespace ID not found for node node name -  
unable to create an entry.  
Explanation: A database audit process cannot find a file space entry for the  
specified node. Because FIX=YES has been specified for the command, the audit  
process has attempted to create a file space entry but is not successful.  
System Action: Audit processing continues.  
532  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your system administrator.  
ANR4200I  
Audit command: Expiring entry node ID and file space filespace ID does not  
match the object entry for object ID object.ID - the entry will be deleted.  
Explanation: A database audit process determines that the specified expiring  
object entry does not match the corresponding object entry for the specified object  
ID. Because FIX=YES has been specified for the command, the expiring object  
entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4201I  
Audit command: Expiring entry node ID and file space filespace ID does not  
match the object entry for object ID object.ID.  
Explanation: A database audit process determines that the specified expiring  
object entry does not match the corresponding object entry for the specified object  
ID.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4202I  
Audit command: The base date for expiration processing of entry object.ID is not  
valid - the entry will be deleted.  
Explanation: A database audit process determines that the specified expiring  
object has a date that is not valid. Because FIX=YES has been specified for the  
command, the expiring object entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4203I  
Audit command: The base date for expiration processing of object object.ID is  
not valid.  
Explanation: A database audit process determines that the specified expiring  
object has a date value that is not valid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
533  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4204I  
Audit command: One or more date values for a backup entry object.ID is not  
valid.  
Explanation: A database audit process determines that one or more of the date  
values is improperly formatted or contains incorrect information for the specified  
backup object.  
System Action: Audit processing continues.  
User Response: Contact your system administrator.  
ANR4205I  
Audit command: The insertion date value for archive entry object.ID is not valid.  
Explanation: A database audit process determines that the insertion date for the  
specified archive object is improperly formatted or contains incorrect information.  
System Action: Audit processing continues.  
User Response: Contact your system administrator.  
ANR4206I  
Audit command: Object entry for expiring object object.ID not found - expiring  
object entry will be deleted.  
Explanation: A database audit process cannot find an object entry corresponding  
to the specified expiring object. Because FIX=YES has been specified for the  
command, the expiring object entry for the specified object ID is deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4207I  
Audit command: Object entry for expiring object object.ID not found.  
Explanation: A database audit process cannot find an object entry corresponding  
to the specified expiring object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4208I  
Audit command: An inventory node assignment entry is not valid for node node  
ID - the entry will be deleted.  
Explanation: A database audit process finds that a node assignment entry for the  
specified node ID is not valid. Since FIX=YES has been specified for the command,  
the required inventory entry is deleted.  
System Action: Audit processing continues.  
534  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4209I  
Audit command: An inventory node assignment entry was not found for node  
node ID.  
Explanation: A database audit process finds that a node assignment entry for the  
specified node ID is not valid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4210I  
Audit command: Auditing physical volume repository definitions.  
Explanation: This message is displayed during a database audit and indicates that  
the physical volume repository definitions are being examined by the database audit  
process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4211I  
Audit command: Drive entry library name for library drive name in the physical  
volume repository is invalid.  
Explanation: A database audit process finds that a drive entry is missing a  
corresponding library entry.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4212I  
Audit command: An object entry for library library name and drive drive name  
in the physical volume repository is invalid - the entry will be deleted.  
Explanation: A database audit process finds that a drive entry is missing a  
corresponding library entry. Because FIX=YES has been specified for the command,  
the invalid drive entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
535  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4213I  
ANR4214I  
ANR4215I  
ANR4216I  
Audit command: A device type for library library name and drive drive name in  
the physical volume repository is invalid.  
Explanation: A database audit process finds that a device type for the specified  
library and drive is invalid.  
System Action: Audit processing continues.  
User Response: Contact the system administrator so that appropriate action may  
be taken.  
Audit command: A drive model for library library name and drive drive name in  
the physical volume repository is invalid.  
Explanation: A database audit process finds that the drive model for the specified  
library and drive is invalid.  
System Action: Audit processing continues.  
User Response: Contact the system administrator so that appropriate action may  
be taken.  
Audit command: An object entry for library library name and volume volume  
name in the physical volume repository is invalid.  
Explanation: A database audit process finds that a library inventory entry is  
missing a corresponding library entry.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: An object entry for library library name and volume volume  
name in the physical volume repository is invalid - the entry will be deleted.  
Explanation: A database audit process finds that a library inventory entry is  
missing a corresponding library entry. Because FIX=YES has been specified for the  
command, the invalid library inventory entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
536  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4217I  
Audit command: The volume status for library library name and volume volume  
name in the physical volume repository is invalid.  
Explanation: A database audit process finds that the volume status for the  
specified library and volume is set to scratch. This is incorrect because storage  
services has a volume name for the library and volume indicating that it should  
have a volume status of private.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4218I  
Audit command: The volume status for library library name and volume volume  
name in the physical volume repository is invalid - the volume status will be  
changed to private.  
Explanation: A database audit process finds that the volume status for the  
specified library and volume is set to scratch. This is incorrect because storage  
services has a volume name for the library and volume which indicates that it  
should have a volume status of private. Because FIX=YES has been specified for  
the command, the incorrect volume status is set to private.  
System Action: Audit processing continues.  
User Response: None.  
ANR4219I  
Audit command: A library type specified for library library name in the physical  
volume repository is invalid.  
Explanation: A database audit process finds that the library type for the specified  
library is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4220I  
Audit command: A library type specified for library library name in the physical  
volume repository is invalid - the library type has been changed to the default  
of library type default.  
Explanation: A database audit process finds that the library type for the specified  
library is invalid. Because FIX=YES has been specified for the command, the  
information is corrected by changing the library type to the default type.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
537  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4221I  
Audit command: An error (error code) was found with archive description for  
node (node identifier), description (description), objects (old object count,new  
object count), count (old directory count,new directory count) - entry will be  
deleted or updated.  
Explanation: A database audit process has found an error with the specified  
archive description. Because FIX=YES has been specified for the command, the  
entry is deleted or updated.  
System Action: Audit processing continues.  
User Response: None.  
ANR4222I  
ANR4223I  
ANR4224I  
Audit command: An error (error code) was found with archive description for  
node (node identifier), description (description), objects (old object count,new  
object count), count (old directory count,new directory count).  
Explanation: A database audit process has found an error with the specified  
archive description.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: An error (error code) was found with converted archive object  
for node (node identifier), description (description identifier), object (object.ID),  
filespace (filespace identifier) - entry will be deleted.  
Explanation: A database audit process has found an error with the specified  
converted archive object. Because FIX=YES has been specified for the command,  
the entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: An error (error code) was found with converted archive object  
for node (node identifier), description (description identifier), object (object.ID),  
filespace (filespace identifier).  
Explanation: A database audit process has found an error with the specified  
converted archive object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
538  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4225I  
Audit command: table entry for archive object (object.ID), node (node identifier),  
description (description), filespace (filespace identifier) not found - the entry will  
be created.  
Explanation: A database audit process cannot find a converted table table entry  
for the specified archive object. Because FIX=YES has been specified for the  
command, an entry will be created.  
System Action: Audit processing continues.  
User Response: None.  
ANR4226I  
ANR4227E  
ANR4228E  
Audit command: table entry for archive object (object.ID), node (node identifier),  
description (description), filespace (filespace identifier) not found.  
Explanation: A database audit process cannot find a converted table table entry  
for the specified archive object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Inconsistent information detected for file aggregate  
(Aggregate.ID).  
Explanation: A database audit process finds inconsistent information for a file  
aggregate. This problem cannot be corrected by the audit process, but the file data is  
not deleted.  
System Action: Audit processing continues.  
User Response: Contact your service representative.  
Audit command: Missing or incorrect information detected for file aggregate  
(Aggregate.ID).  
Explanation: A database audit process detects missing or incorrect information for  
a file aggregate. This information can be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
539  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4229E  
Audit command: Missing or incorrect information detected for file aggregate  
(Aggregate.ID) - It will be corrected.  
Explanation: A database audit process detects missing or incorrect information for  
a file aggregate. Because FIX=YES has been specified for the audit command, the  
error will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4230I  
Audit command: Auditing data storage definitions.  
Explanation: This message is displayed during a database audit and indicates that  
the data storage definitions are being examined by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4231E  
Audit command: Invalid device class strategy strategy for device class device  
class name.  
Explanation: A database audit process finds a device class with an invalid access  
strategy.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the access  
strategy can be corrected.  
ANR4232E  
Audit command: Invalid device class strategy strategy for device class device  
class name - information will be corrected.  
Explanation: A database audit process finds a device class with an invalid access  
strategy. Because FIX=YES has been specified for the audit command, the access  
strategy will be corrected for this device class.  
System Action: Audit processing continues.  
User Response: None.  
ANR4233E  
Audit command: Pool ID information is missing or incorrect for storage pool  
storage pool name.  
Explanation: A database audit process finds a storage pool whose pool ID  
information is missing or incorrect.  
System Action: Audit processing continues.  
540  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command with FIX=YES so that the access  
strategy can be corrected.  
ANR4234E  
Audit command: Pool ID information is missing or incorrect for storage pool  
storage pool name - information will be created or corrected.  
Explanation: A database audit process finds a storage pool whose pool ID  
information is missing or incorrect. Because FIX=YES has been specified for the  
audit command, the pool ID information will be created or corrected for this storage  
pool.  
System Action: Audit processing continues.  
User Response: None.  
ANR4235E  
Audit command: Device class ID referenced by storage pool storage pool name is  
not defined - data in this pool may not be available.  
Explanation: A database audit process finds a storage pool which references a  
device class ID which is not defined.  
System Action: Audit processing continues.  
User Response: Contact your service representative.  
ANR4236E  
Audit command: An invalid access strategy was encountered for storage pool  
storage pool name.  
Explanation: A database audit process encounters an invalid device access strategy  
for the specified storage pool.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the attribute  
can be corrected.  
ANR4237E  
Audit command: An invalid access strategy was encountered for storage pool  
storage pool name - the strategy will be corrected.  
Explanation: A database audit process encounters an invalid device access strategy  
for the specified storage pool. Because FIX=YES has been specified for the  
command, the storage pool access strategy will be corrected.  
System Action: Audit processing continues.  
User Response: After the audit command completes, examine the storage pool  
using the QUERY STGPOOL command, and verify that the correct information is  
displayed for this storage pool.  
Tivoli Storage Manager Messages  
541  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4238E  
Audit command: Storage pool storage pool name specifies an undefined pool ID  
for its next storage pool.  
Explanation: The specified storage pool references an invalid pool ID as its next  
storage pool.  
System Action: Audit processing continues.  
User Response: Use the UPDATE STGPOOL command to update the next pool.  
Alternatively, if the audit command is reissued with FIX=YES, the reference to the  
next pool will be deleted.  
ANR4239E  
Audit command: Storage pool storage pool name specifies an undefined pool ID  
for its next storage pool - reference will be deleted.  
Explanation: The specified storage pool references an invalid pool ID as its next  
storage pool. Because FIX=YES has been specified for the command, the reference  
is deleted. The specified storage pool will not have a next pool.  
System Action: Audit processing continues.  
User Response: After the audit command completes, use the UPDATE STGPOOL  
command to assign a next storage pool, if desired.  
ANR4240E  
Audit command: An invalid attribute was encountered for storage pool storage  
pool name.  
Explanation: A database audit process encounters an invalid attribute for the  
specified storage pool.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the attribute  
can be corrected.  
ANR4241E  
Audit command: An invalid attribute was encountered for storage pool storage  
pool name - the attribute will be assigned its default value.  
Explanation: A database audit process encounters an invalid attribute for the  
specified storage pool. Because FIX=YES has been specified for the command, the  
storage pool will be corrected using the default value for the attribute.  
System Action: Audit processing continues.  
User Response: After the audit command completes, examine the storage pool  
using the QUERY STGPOOL command, and correct attributes with the UPDATE  
STGPOOL command, if desired.  
542  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4242E  
ANR4243E  
ANR4244E  
Audit command: Invalid administrator update information encountered for  
storage pool storage pool name.  
Explanation: A database audit process finds incorrect information pertaining to the  
last update for the specified storage pool.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid administrator update information encountered for  
storage pool storage pool name - information will be corrected.  
Explanation: A database audit process finds incorrect information pertaining to the  
last update for the specified storage pool. Because FIX=YES has been specified for  
the command, the information is corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Storage pool ID referenced by volume volume name is not  
defined - data on this volume may not be available.  
Explanation: A database audit process finds a data storage volume which  
references a storage pool ID that is not defined.  
System Action: Audit processing continues.  
User Response: You can attempt to move data on the specified volume to other  
volumes using the MOVE DATA command; then delete the specified volume and  
redefine it. If this does not work, contact your service representative.  
ANR4245E  
Audit command: An invalid access strategy was encountered for volume volume  
name.  
Explanation: A database audit process encounters an invalid device access strategy  
for the specified volume.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the strategy  
can be corrected.  
Tivoli Storage Manager Messages  
543  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4246E  
Audit command: An invalid access strategy was encountered for volume volume  
name - the strategy will be corrected.  
Explanation: A database audit process encounters an invalid device access strategy  
for the specified volume. Because FIX=YES has been specified for the command,  
the access strategy will be corrected for this volume.  
System Action: Audit processing continues.  
User Response: None.  
ANR4247E  
Audit command: Missing information for volume volume name cannot be created.  
Delete the volume after optionally moving any files from the volume.  
Explanation: A database audit process encounters missing database information  
for the specified volume. Since FIX=YES has been specified for the audit  
command, an attempt is made to create the missing information where possible.  
However, some of the information cannot be created, and the volume must be  
deleted.  
System Action: The access mode for the volume is set to UNAVAILABLE to  
prevent further attempts to write to this volume. Audit processing continues.  
User Response: After audit processing completes, an administrator should take the  
following actions to eliminate the volume  
(Optional) Use the UPDATE VOLUME command to set the access mode for  
the volume to READWRITE. It may then be possible to use the MOVE DATA  
command to move files from the volume so that these files can be accessed by  
the server.  
(Required) Use the DELETE VOLUME command to delete the volume from  
the database.  
ANR4248E  
Audit command: Missing or incorrect information for storage volume volume  
name.  
Explanation: A database audit process finds a data storage volume for which  
information is missing or incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be created or corrected.  
544  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4249E  
Audit command: Missing or incorrect information for storage volume volume  
name - information will be created or corrected.  
Explanation: A database audit process finds a data storage volume for which  
information is missing or incorrect. Since FIX=YES has been specified for the audit  
command, the information will be created or corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4250E  
ANR4251E  
ANR4252E  
ANR4253E  
Audit command: Extraneous reference found.  
Explanation: A database audit process finds a reference to a nonexistent entity  
such as a storage pool or volume.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information is deleted.  
Audit command: Extraneous reference found - information will be deleted.  
Explanation: A database audit process finds a reference to a nonexistent entity  
such as a storage pool or volume. Since FIX=YES has been specified for the audit  
command, the extraneous information will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Data storage global attributes cannot be found.  
Explanation: A database audit process is not able to locate the global attributes for  
data storage in the server database.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Data storage global attributes cannot be found - attributes will  
be recreated.  
Explanation: A database audit process is not able to locate the global attributes for  
data storage in the server database. Because FIX=YES has been specified for the  
audit command, the attributes will be regenerated.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
545  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4254E  
Audit command: Data storage high-water marks do not match the identifiers in  
use.  
Explanation: A database audit process finds that the information used to track data  
storage identifiers is incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4255E  
Audit command: Data storage high-water marks do not match the identifiers in  
use - they will be corrected.  
Explanation: A database audit process finds that the information used to track data  
storage identifiers is incorrect. Because FIX=YES has been specified for the audit  
command, the error will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4256I  
Audit command: Auditing data storage definitions for disk volumes.  
Explanation: This message is displayed during a database audit and indicates that  
the database information relating to data storage disk volumes is being examined by  
the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4257E  
Audit command: A correctable data-integrity error was detected on volume  
volume name.  
Explanation: A database audit process finds a data-integrity error for a file stored  
on the specified volume. This error is correctable.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
546  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4258E  
ANR4259E  
ANR4260E  
ANR4261E  
Audit command: A data-integrity error was detected on volume volume name -  
the error will be corrected.  
Explanation: A database audit process finds a correctable data-integrity error for a  
file stored on the specified volume. Because FIX=YES has been specified for the  
audit command, the error will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Invalid data encountered for a file in data storage - data can  
be corrected.  
Explanation: A database audit process finds invalid data for a file in data storage.  
The error should be correctable.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid data encountered for a file in data storage - the error  
will be corrected.  
Explanation: A database audit process finds invalid data for a file in data storage.  
Because FIX=YES has been specified for the audit command, the error will be  
corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Invalid access information was encountered for volume volume  
name.  
Explanation: A database audit process encounters invalid access information for  
the specified volume.  
System Action: Audit processing continues.  
User Response: After audit processing has completed, use the UPDATE  
VOLUME command to set the access information for this volume. Or reissue the  
audit command with FIX=YES, which sets access to the default value.  
Tivoli Storage Manager Messages  
547  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4262E  
Audit command: Invalid access information was encountered for volume volume  
name - the information will be corrected.  
Explanation: A database audit process encounters invalid access information for  
the specified volume. Because FIX=YES has been specified for the command, the  
information will be corrected by setting the default value.  
System Action: Audit processing continues.  
User Response: After audit processing has completed, use the UPDATE  
VOLUME command to set the access information for this volume, if desired.  
ANR4263I  
Audit command: Auditing data storage definitions for sequential volumes.  
Explanation: This message is displayed during a database audit and indicates that  
the database information relating to data storage sequential volumes is being  
examined by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4264I  
Audit command: Auditing file information.  
Explanation: This message is displayed during a database audit and indicates that  
information on stored files is being examined by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4265I  
Audit command: Auditing disk file information.  
Explanation: This message is displayed during a database audit and indicates that  
information on files stored on disk media is being examined by the database audit  
process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4266I  
Audit command: Auditing sequential file information.  
Explanation: This message is displayed during a database audit and indicates that  
information on files stored on sequential media is being examined by the database  
audit process.  
System Action: Audit processing continues.  
User Response: None.  
548  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4267E  
Audit command: A storage pool containing file data cannot be located - file data  
may not be accessible.  
Explanation: This message is displayed during a database audit and indicates that  
the storage pool containing a file’s data cannot be located or is not defined. This  
problem cannot be corrected by the audit process, but the file data is not deleted.  
System Action: Audit processing continues.  
User Response: Contact your service representative.  
ANR4268E  
Audit command: A storage volume containing file data cannot be located - file  
data may not be accessible.  
Explanation: This message is displayed during a database audit and indicates that  
the storage volume containing a file’s data cannot be located or is not defined. This  
problem cannot be corrected by the audit process, but the file data is not deleted.  
System Action: Audit processing continues.  
User Response: Contact your service representative.  
ANR4269E  
Audit command: Extraneous file data reference found.  
Explanation: A database audit process finds a reference to a file that no longer  
exists.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be deleted.  
ANR4270E  
Audit command: Extraneous file data reference found - information will be  
deleted.  
Explanation: A database audit process finds a reference to a file that no longer  
exists. Because FIX=YES has been specified for the audit command, the  
information will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4271E  
Audit command: Missing or incorrect occupancy information detected.  
Explanation: A database audit process detects missing or incorrect occupancy  
information for a data storage pool or a data storage volume.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
549  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command with FIX=YES so that the  
information can be created or corrected.  
ANR4272E  
Audit command: Missing or incorrect occupancy information detected -  
information will be created or corrected.  
Explanation: A database audit process detects missing or incorrect occupancy  
information for a data storage pool or a data storage volume. Because FIX=YES has  
been specified for the audit command, the information will be created or corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4273E  
Audit command: A data-integrity error was detected on volume volume name -  
Issue the AUDIT VOLUME command to correct the error.  
Explanation: A database audit process finds a data-integrity error for a file stored  
on the specified volume.  
System Action: Audit processing continues.  
User Response: Issue the AUDIT VOLUME command on the specified volume to  
correct the data-integrity error.  
ANR4274E  
Audit command: A correctable data-integrity error was detected.  
Explanation: A database audit process finds a data-integrity error for a stored file.  
This error can be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4275E  
Audit command: A data-integrity error was detected - it will be corrected.  
Explanation: A database audit process finds a data-integrity error for a stored file.  
Because FIX=YES has been specified for the audit command, the error will be  
corrected.  
System Action: Audit processing continues.  
User Response: None.  
550  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4276E  
Audit command: Invalid file storage information detected - file data is not  
accessible.  
Explanation: A database audit process finds invalid file storage information for a  
stored file, and it cannot be corrected.  
System Action: Audit processing continues.  
User Response: Issue the AUDIT VOLUME command on all your volumes to  
correct the data-integrity error.  
ANR4277E  
ANR4278E  
ANR4279E  
Audit command: Invalid file storage information detected.  
Explanation: A database audit process finds invalid file storage information for a  
stored file. This information can be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Invalid file storage information detected - It will be corrected.  
Explanation: A database audit process finds invalid file storage information for a  
stored file. Because FIX=YES has been specified for the audit command, the error  
will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Administrator administrator number assigned to more than just  
system authority class.  
Explanation: A database audit process finds that an administrator is assigned to  
other authority classes. Being assigned with 'SYSTEM' authority supersedes all  
other classes and the other privilege class entries should be deleted.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4280I  
Audit command: Administrator administrator number assigned to more than just  
system authority class - the other class entries will be deleted.  
Explanation: A database audit process finds that an administrator is assigned to  
other authority classes. Being assigned with 'SYSTEM' authority supersedes all  
Tivoli Storage Manager Messages  
551  
Download from Www.Somanuals.com. All Manuals Search And Download.  
other classes and the other privilege class entries should be deleted. Because  
FIX=YES has been specified for the command, any authority class other than  
system will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4281E  
ANR4282I  
ANR4283E  
Audit command: Administrator administrator number assigned as an unrestricted  
policy administrator is also assigned as a restricted administrator for domain  
domain name.  
Explanation: A database audit process finds the specified administrator is assigned  
as an unrestricted policy administrator. The specified administrator is also assigned  
as the restricted administrator for the specified policy domain. The unrestricted  
policy administration class supersedes any restricted policy class definitions for an  
administrator. The administrator’s authority needs to be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Administrator administrator number assigned as an unrestricted  
policy administrator is also assigned as administrator for domain domain name -  
restricted class entry will be deleted.  
Explanation: A database audit process finds the specified administrator is assigned  
as an unrestricted policy administrator. The specified administrator is also assigned  
as the restricted administrator for the specified policy domain. The unrestricted  
policy administration class supersedes any restricted policy class definitions for an  
administrator. Because FIX=YES has been specified for the command, the restricted  
administrator policy class will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Administrator administrator number assigned as an unrestricted  
storage administrator is also assigned as a restricted administrator for storage  
pool storage pool name.  
Explanation: A database audit process finds the specified administrator is assigned  
as an unrestricted storage administrator. The specified administrator is also assigned  
as the restricted administrator for the specified storage pool. The unrestricted storage  
administration class supersedes any restricted storage class definitions for an  
administrator. The administrator’s authority needs to be corrected.  
System Action: Audit processing continues.  
552  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4284I  
Audit command: Administrator administrator number assigned as an unrestricted  
storage administrator is also assigned as a restricted administrator for storage  
pool storage pool name - restricted class entry will be deleted.  
Explanation: A database audit process finds the specified administrator is assigned  
as an unrestricted storage administrator. The specified administrator is also assigned  
as the restricted administrator for the specified storage pool. The unrestricted storage  
administration class supersedes any restricted storage class definitions for an  
administrator. Because FIX=YES has been specified for the command, the restricted  
administrator storage class will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4285E  
ANR4286E  
ANR4287E  
Audit command: A data-integrity error was detected on a storage volume for  
object (Object.ID).  
Explanation: A database audit process found a data-integrity error for a file stored  
on a storage volume, but the specific volume name is not known. If fix=yes was  
specified, the audit process will attempt to correct the data-integrity error.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: A correctable storage allocation error detected for volume  
volume name.  
Explanation: A database audit process finds incorrect block allocation information  
for the specified storage volume; the error can be corrected.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Storage allocation error detected for volume volume name - It  
will be corrected.  
Explanation: A database audit process finds incorrect block allocation information  
for the specified storage volume; the error will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
553  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4288E  
ANR4289E  
ANR4290I  
Audit command: Multiple files allocated the same disk storage block on volume  
volume name.  
Explanation: A database audit process finds multiple files allocated the same disk  
storage block on the specified volume; this error cannot be corrected by the audit  
process.  
System Action: Audit processing continues.  
User Response: Contact your service representative.  
Audit command: Multiple files allocated the same disk storage block on volume  
volume name.  
Explanation: A database audit process finds multiple files allocated the same disk  
storage block on the specified volume; this error cannot be corrected by the audit  
process.  
System Action: Audit processing continues.  
User Response: Contact your service representative.  
Audit command: License global attributes could not be found - they will be  
created.  
Explanation: A database audit process cannot find the license global attributes.  
Because FIX=YES has been specified for the command, the information is corrected  
by the creation of the global attributes.  
System Action: Audit processing continues.  
User Response: None.  
ANR4291I  
Audit command: License global attributes could not be found.  
Explanation: A database audit process cannot find the license global attributes.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4292I  
Audit command: Invalid table active column encountered for license global  
attribute - the value will be corrected.  
Explanation: A database audit process finds that the active column license global  
attribute is invalid. Because FIX=YES has been specified for the command, the  
active column is reset to a proper value.  
System Action: Audit processing continues.  
554  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4293I  
ANR4294I  
ANR4295I  
ANR4296I  
Audit command: Invalid table active column encountered for license global  
attributes.  
Explanation: A database audit process finds that the active column license global  
attribute is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: A license node assignment entry was not found for node node  
ID - an entry will be created.  
Explanation: A database audit process cannot find the node assignment entry  
corresponding to the specified node. Since FIX=YES has been specified for the  
command, the required license entry will be created using default values.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: A license node assignment entry was not found for node node  
ID.  
Explanation: A database audit process cannot find the node assignment entry  
corresponding to the specified node.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: An invalid license node assignment entry was found for node  
node ID - the entry will be deleted.  
Explanation: A database audit process finds that the license node assignment entry  
is invalid. Because FIX=YES has been specified for the command, the node entry is  
deleted.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
555  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4297I  
Audit command: An invalid license node assignment entry was found for node  
node ID.  
Explanation: A database audit process finds that the license node assignment entry  
is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4298I  
Expiration thread already processing - unable to begin another expiration  
process.  
Explanation: The expiration thread is already processing. The processing  
expiration thread is either an EXPIRE INVENTORY command or is the automatic  
background expiration process. In either case, another expiration process cannot be  
started until the current expiration process completes or is canceled.  
System Action: Current expiration process continues.  
User Response: Use the QUERY PROCESS command to determine the status of  
the current expiration process.  
ANR4299I  
Audit command: Invalid audit interval encountered for license global attribute -  
the value will be set to the default.  
Explanation: A database audit process finds that the audit interval license global  
attribute is invalid. Because FIX=YES has been specified for the command, the  
audit interval is reset to the default value.  
System Action: Audit processing continues.  
User Response: None.  
ANR4300I  
Audit command: Invalid audit interval encountered for license global attributes.  
Explanation: A database audit process finds that the audit interval license global  
attribute is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
556  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4301I  
Audit command: Invalid last audit date encountered for license global attribute -  
the value will be set to 0.  
Explanation: A database audit process finds that the last audit date license global  
attribute is invalid. Because FIX=YES has been specified for the command, the last  
audit date is set to 0. The next execution of AUDIT LICENSES will set a new last  
audit date.  
System Action: Audit processing continues.  
User Response: None.  
ANR4302I  
ANR4303E  
ANR4304E  
Audit command: Invalid last audit date encountered for license global attribute.  
Explanation: A database audit process finds that the last audit date license global  
attribute is invalid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Inventory references for object(Object.ID) deleted.  
Explanation: A database audit process deleted all inventory references for the  
specified object ID. This process corrects a data-integrity error if FIX=YES was  
specified.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: object name missing entry for cluster cluster ID - cluster entries  
deleted.  
Explanation: A database audit process is missing a corresponding entry for the  
specified comparison object and cluster ID. This process indicates a data-integrity  
error for the database cluster information. If FIX=YES was specified, the invalid  
cluster information will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4305E  
Audit command: object name missing entry for cluster cluster ID.  
Explanation: A database audit process is missing a corresponding entry for the  
specified comparison object and cluster ID. This indicates a data-integrity error for  
the database cluster information.  
Tivoli Storage Manager Messages  
557  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4306I  
AUDITDB: Processed number of entries database entries (cumulative).  
Explanation: This message indicates the number of database entries that have  
been processed during database audit processing.  
System Action: Database audit processing continues.  
User Response: None.  
ANR4307I  
Audit command: Auditing inventory external space-managed objects.  
Explanation: This message is displayed during a database audit and indicates that  
server information about external space-managed client objects is currently being  
examined by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4308I  
Audit command: External space-managed entry for node node ID and file space  
filespace ID is missing a corresponding space-managed object entry - the  
external space-managed entry will be deleted.  
Explanation: A database audit process finds that an external space-managed entry  
is missing a corresponding space-managed entry. Because FIX=YES has been  
specified, the orphaned external space-managed entry is deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4309I  
Audit command: External space-managed entry for node node ID and file space  
filespace ID is missing a corresponding space-managed object entry.  
Explanation: A database audit process finds that an external space-managed entry  
is missing a corresponding space-managed entry.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
558  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4310I  
Audit command: Auditing inventory space-managed objects.  
Explanation: This message is displayed during a database audit and indicates that  
server information about space-managed client objects is currently being examined  
by the database audit process.  
System Action: Audit processing continues.  
User Response: None.  
ANR4311I  
Audit command: Object entry for space-managed object object.ID not found -  
entry will be created.  
Explanation: A database audit process cannot find an object entry for the specified  
space-managed object. Because FIX=YES has been specified for the command, an  
object entry is created by using default values.  
System Action: Audit processing continues.  
User Response: None.  
ANR4312I  
Audit command: Object entry for space-managed object object.ID not found.  
Explanation: A database audit process cannot find an object entry for the specified  
backup object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4313I  
Audit command: Space-managed object (object ID) for node node ID and file  
space filespace ID has one or more incorrect fields - the values will be  
corrected.  
Explanation: A database audit process determined that one or more field values  
for the specified space-managed object is not valid. Because FIX=YES was  
specified the values are corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4314I  
Audit command: Space-managed object (object ID) for node node ID and file  
space filespace ID has one or more incorrect fields.  
Explanation: A database audit process determined that one or more field values  
for the specified space-managed object is not valid.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
559  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4315I  
Audit command: Space-managed object (object ID) for node node ID and file  
space filespace ID is missing the corresponding external space managed entry -  
the entry will be created.  
Explanation: A database audit process determines that the space-managed object  
entry is missing a corresponding external space managed entry. Because FIX=YES  
was specified, the missing entry will be created.  
System Action: Audit processing continues.  
User Response: None.  
ANR4316I  
Audit command: Space-managed object (object ID) for node node ID and file  
space filespace ID is missing the corresponding external space managed entry.  
Explanation: A database audit process determines that the space-managed object  
entry is missing a corresponding external space-managed entry.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4317I  
Audit command: External space-managed object (object ID) for node node ID  
and file space filespace ID has one or more incorrect fields - the values will be  
corrected.  
Explanation: A database audit process determined that one or more field values  
for the specified external space-managed object is not valid. Because FIX=YES was  
specified, the values will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4318I  
Audit command: External space-managed object (object ID) for node node ID  
and file space filespace ID has one or more incorrect fields.  
Explanation: A database audit process determined that one or more field values  
for the specified external space-managed object is not valid.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
560  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4319I  
Audit command: Space-managed object not found for object object.ID - object  
entry will be deleted.  
Explanation: A database audit process cannot find a space-managed object entry  
for the specified object. Because FIX=YES was specified the object entry will be  
deleted.  
System Action: Audit processing continues.  
User Response: None.  
ANR4320I  
Audit command: Space-managed object not found for object object.ID.  
Explanation: A database audit process cannot find a space-managed object entry  
for the specified object.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4321I  
Audit command: Invalid copy type encountered for object object.ID - object  
found as an space-managed object - correcting the invalid copy type  
Explanation: A database audit process encounters an invalid copy type for the  
specified object ID, but finds a corresponding space-managed object for the entry.  
Because FIX=YES has been specified for the command, the invalid copy type is  
corrected.  
System Action: Audit processing continues.  
User Response: None.  
ANR4322E  
Audit command: Management class class name in policy set set name, domain  
domain name does not have a valid space management technique defined.  
Explanation: A database audit process finds a management class that does not  
have a valid value specified.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Tivoli Storage Manager Messages  
561  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4323E  
Audit command: Management class class name in policy set set name, domain  
domain name does not have a valid space management technique defined - the  
default value will be set.  
Explanation: A database audit process finds a management class that does not  
have a valid value specified. Because FIX=YES was specified for the AUDITDB  
operation, the default space management technique value will be set for the  
management class specified.  
System Action: Audit processing continues.  
User Response: Refer to the DEFINE MGMTCLASS command in the  
Administrators Reference for valid values.  
ANR4324E  
Audit command: Management class class name in policy set set name, domain  
domain name does not have a valid AUTOMIGNONUSE value specified.  
Explanation: A database audit process finds a management class that does not  
have a valid value specified.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
ANR4325E  
Audit command: Management class class name in policy set set name, domain  
domain name does not have a valid AUTOMIGNONUSE value defined - the  
default value will be set.  
Explanation: A database audit process finds a management class that does not  
have a valid value specified. Because FIX=YES was specified for the AUDITDB  
operation, the default AUTOMIGNONUSE value will be set for the management  
class specified.  
System Action: Audit processing continues.  
User Response: Refer to the DEFINE MGMTCLASS command in the  
Administrators Reference for valid values.  
ANR4326E  
Audit command: Management class class name in policy set set name, domain  
domain name does not have a valid MIGREQUIRESBKUP value specified.  
Explanation: A database audit process finds a management class that does not  
have a valid value specified.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
562  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4327E  
Audit command: Management class class name in policy set set name, domain  
domain name does not have a valid MIGREQUIRESBKUP value defined - the  
default value will be set.  
Explanation: A database audit process finds a management class that does not  
have a valid value specified. Because FIX=YES was specified for the AUDITDB  
operation, the default MIGREQUIRESBKUP value will be set for the management  
class specified.  
System Action: Audit processing continues.  
User Response: Refer to the DEFINE MGMTCLASS command in the  
Administrators Reference for valid values.  
ANR4328W  
Audit command: Storage pool storage pool name, specified as a space  
management destination for management class management class name, policy  
set set name, domain domain name, does not exist.  
Explanation: A database audit process encounters a storage pool specified for the  
space management destination of the specified management class that is not defined  
in the server database. If this management class is used in an active policy set, then  
migration operations will fail when attempting to put client data in the destination.  
System Action: Audit processing continues.  
User Response: After the audit command completes, use the DEFINE STGPOOL  
command to define the missing storage pool or the UPDATE MGMTCLASS  
command to update the management class to refer to an existing storage pool.  
ANR4329I  
Audit command: Inactive reference found for active backup entry (Object.ID) -  
the inactive reference will be deleted.  
Explanation: A database audit process found that an active backup entry for the  
specified object has a corresponding inactive backup entry. Since FIX=YES was  
specified for the command, the information is corrected by deleting the inactive  
backup object entry.  
System Action: Audit processing continues.  
User Response: None.  
ANR4330I  
Audit command: Inactive reference found for active backup entry (Object.ID).  
Explanation: A database audit process found that an active backup entry for the  
specified object has a corresponding inactive backup entry.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
563  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4331E  
command process terminated, no matching device classes.  
Explanation: The server did not find any device class names matching the  
specifications entered in the RECONCILE VOLUMES command.  
System Action: Server operation continues.  
User Response: Use the QUERY DEVCLASS command to determine which  
device classes are defined on the server and reissue the RECONCILE VOLUMES  
command.  
ANR4332W  
This command will compare all volumes used by the specified device class(es)  
with the actual data stored on the associated server for those volumes and will  
report any discrepancies; the data will be inaccessible to users until the  
operation completes.  
Explanation: During the execution of a RECONCILE VOLUMES command, any  
data a volume named would be unavailable to users.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to reconcile the volumes or 'N' to stop the process.  
ANR4333W  
This command will discard any references to volumes used by the specified  
device class(es) that are missing from the associated server, thereby rendering  
the data unrecoverable; the valid volumes will be inaccessible to users until the  
operation completes.  
Explanation: During the execution of a RECONCILE VOLUMES command, any  
data on a volume being reconciled would be unavailable to users. After the  
command has ended, any inconsistent volumes found will be discarded.  
System Action: The administrator is asked whether to continue.  
User Response: Enter 'Y' to reconcile the volumes or 'N' to stop the process.  
ANR4334I  
command (Repair) process started, process ID process ID.  
Explanation: As the result of a RECONCILE VOLUMES command that specified  
FIX=YES, the process whose ID is displayed has begun reconciling the volumes  
associated with the given device class.  
System Action: The volumes are reconciled and invalid volumes are displayed.  
User Response: None.  
564  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4335I  
command (Inspect Only) process started, process ID process ID.  
Explanation: As the result of a RECONCILE VOLUMES command that specified  
FIX=NO, the process whose ID is displayed has begun reconciling the volumes  
associated with the given device class.  
System Action: The volumes are reconciled and inconsistent volumes are  
displayed.  
User Response: None.  
ANR4336W  
command process ended, process ID process ID.  
Explanation: The RECONCILE VOLUMES command for the specified device  
class has ended.  
System Action: None.  
User Response: For complete details on the results of the RECONCILE  
VOLUMES command, examine the previous messages.  
ANR4337W  
command process terminated - process canceled.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
process performing the reconcile was canceled.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: None.  
ANR4338W  
command process terminated - sufficient recovery log space is not available.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
source server does not have sufficient recovery log space to continue.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: If necessary, make more recovery log space available to the  
source server.  
ANR4339W  
command process terminated - sufficient database space is not available.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
source server does not have sufficient database space to continue.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: If necessary, make more database space available to the source  
server.  
Tivoli Storage Manager Messages  
565  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4340W  
command process terminated - thread resource not available.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
source server cannot start a thread for the reconcile process.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: Reissue the RECONCILE VOLUMES command. If the error  
persists, it may indicate a shortage of source server memory.  
ANR4341W  
ANR4342W  
ANR4343W  
ANR4344I  
command process terminated - sufficient memory is not available.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
source server does not have enough memory available to complete the command.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: If necessary make more memory available to the source server.  
command process terminated - lock conflict detected.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
source server cannot obtain a required lock.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: Reissue the RECONCILE VOLUMES command.  
command process terminated - internal server error detected.  
Explanation: During processing of a RECONCILE VOLUMES command, an  
internal server error occurs on the source server.  
System Action: The RECONCILE VOLUMES command is ended.  
User Response: Contact your service representative.  
command started for device class device class (process ID process ID).  
Explanation: The RECONCILE VOLUMES process whose ID is displayed has  
started reconciling volumes associated with the given device class.  
System Action: The volumes are reconciled and inconsistent volumes are  
displayed.  
User Response: None.  
566  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4345I  
command completed for device class device class; (process ID process ID);  
volume count volumes inspected, volume count invalid volumes found, volume  
count volumes deleted.  
Explanation: The RECONCILE VOLUMES process whose ID is displayed has  
finished reconciling volumes associated with the given device class. The number of  
volumes reconciled and the number of invalid volumes found or deleted are  
displayed.  
System Action: None.  
User Response: For complete details on the results of the RECONCILE  
VOLUMES command for the shown device class, examine the previous messages.  
ANR4346I  
command completed for device class device class; (process ID process ID);  
volume count volumes inspected, volume count invalid volumes found.  
Explanation: The RECONCILE VOLUMES process whose ID is displayed has  
finished reconciling volumes associated with the given device class. The number of  
volumes reconciled and the number of invalid volumes found are displayed.  
System Action: None.  
User Response: For complete details on the results of the RECONCILE  
VOLUMES command for the shown device class, examine the previous messages.  
If you suspect that volumes were inaccessible because of communications problems,  
correct the problems and retry the RECONCILE VOLUMES command. If the errors  
are valid, reissue the reconcile volumes command with FIX=YES so that the source  
server can attempt to correct the information.  
ANR4352I  
Contacting Server server name  
Explanation: This message is displayed in response to a QUERY PROCESS  
command, and indicates that a reconciliation process is attempting to obtain volume  
information from the shown server.  
System Action: The reconciliation process continues.  
User Response: None.  
ANR4353I  
Cancel in progress  
Explanation: This message is displayed in response to a QUERY PROCESS  
command, and indicates that a reconciliation process has been canceled. The process  
will end shortly.  
System Action: The reconciliation process terminates and server operation  
continues.  
Tivoli Storage Manager Messages  
567  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4354W  
command: Source server not authorized to reconcile target server server name.  
Explanation: During processing of a RECONCILE VOLUMES command, the  
source server was not permitted to reconcile volume on the shown target server.  
System Action: The reconciliation process continues.  
User Response: If the source server should have permission to reconcile volumes  
on the shown target server, issue the UPDATE SERVER command with  
FORCESYNC=YES to cause the target server to accept reconcile operations for the  
source server. Reissue the RECONCILE VOLUMES command.  
ANR4355W  
command: Volume volume name not valid, source server missing corresponding  
entry for target server.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was reported by the target server and it has no matching volume on the  
source server.  
System Action: The reconciliation process continues.  
User Response: The database on either the source or target server has been  
regressed by either a RESTORE DATABASE operation or some system facility  
external to the server. Investigate the action that caused one or both of the databases  
to be regressed to there current condition. If a newer database images exist for that  
server, consider restoring the server to that point in time. If the condition of the  
database on each server is acceptable and the RECONCILE VOLUMES command  
was issued with FIX=NO, reissue the RECONCILE VOLUMES command with  
FIX=Yes to have the volume deleted from the target server.  
ANR4356W  
command: Volume volume name not valid, target server missing corresponding  
entry for source server.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was found on the source server and it has no matching volume on the target  
server.  
System Action: The reconciliation process continues.  
User Response: The database on either the source or target server has been  
regressed by either an RESTORE DATABASE operation or some system facility  
external to the server. Investigate the action that caused one or both of the databases  
to be regressed to there current condition. If a newer database images exist for that  
server, consider restoring the server to that point in time. If the RECONCILE  
VOLUMES command was issued with FIX=Yes and the volume is defined in a  
storage pool, the access mode of the volume will changed to unavailable to prevent  
568  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
attempted mounts on the source server. If the condition of the database on each  
server is acceptable, issue the DELETE VOLUME or DELETE VOLHISTORY  
command on the source server to remove the volume from the database.  
ANR4357W  
command: Volume volume name not valid, target server volume refers to device  
class device class that does not exist on the source server.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was found on the target server and it is associated with the device class  
shown. The source server has NO corresponding device class.  
System Action: The reconciliation process continues.  
User Response: The database on either the source or target server has been  
regressed by either an RESTORE DATABASE operation or some system facility  
external to the server. Investigate the action that caused one or both of the databases  
to be regressed to their current condition. If a newer database image exist for that  
server, consider restoring the server to that point in time. In the case of a volume in  
the VOLHISTORY, the device class may have been deleted from the source server.  
If possible, issue the DEFINE DEVCLASS command to correct the situation. If the  
condition of the database on each server is acceptable and the RECONCILE  
VOLUMES command was issued with FIX=NO, reissue the RECONCILE  
VOLUMES command with FIX=Yes to have the volume deleted from the target  
server.  
ANR4358W  
command: Volume volume name not valid, the attributes of the volume on target  
server do not match the attributes on the source server.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was found on both the source and target server, but the attributes describing  
the volume does not match.  
System Action: The reconciliation process continues.  
User Response: The database on either the source or target server has been  
regressed by either a RESTORE DATABASE operation or some system facility  
external to the server. Investigate the action that caused one or both of the databases  
to be regressed to there current condition. If a newer database image exist for that  
server, consider restoring the server to that point in time. If the condition of the  
database on each server is acceptable, additional actions will have to be taken  
because RECONCILE VOLUMES FIX=YES is unable to correct this situation. In  
the case of a volume in the VOLHISTORY, an IMPORT PREVIEW=YES or a  
RESTORE DATABASE PREVIEW=YES will determine the integrity of the  
volume. If the volume is in error, a DELETE VOLHISTORY will remove the  
volume from both the source and target servers. In the case of a volume in a storage  
pool, an AUDIT VOLUME FIX=NO will determine the integrity of the volume. If  
errors are found, an AUDIT VOLUME FIX=YES may make some data on the  
Tivoli Storage Manager Messages  
569  
Download from Www.Somanuals.com. All Manuals Search And Download.  
volume accessible. Otherwise, issue the DELETE VOLUME command on the  
source server to remove the volume from both the source and target servers.  
ANR4359W  
command: Volume volume name not valid, the size of the volume on target  
server does not match the size on the source server.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was found on both the source and target server, but the size of the volume  
does not match.  
System Action: The reconciliation process continues.  
User Response: The database on either the source or target server has been  
regressed by either an RESTORE DATABASE operation or some system facility  
external to the server. Investigate the action that caused one or both of the databases  
to be regressed to there current condition. If a newer database image exist for that  
server, consider restoring the server to that point in time. If the condition of the  
database on each server is acceptable, additional actions will have to be taken  
because RECONCILE VOLUMES FIX=YES is unable to correct this situation. In  
the case of a volume in the VOLHISTORY, an IMPORT PREVIEW=YES or a  
RESTORE DATABASE PREVIEW=YES will determine the integrity of the  
volume. If the volume is in error, a DELETE VOLHISTORY will remove the  
volume from both the source and target servers. In the case of a volume in a storage  
pool, an AUDIT VOLUME FIX=NO will determine the integrity of the volume. If  
errors are found, an AUDIT VOLUME FIX=YES may make some data on the  
volume accessible. Otherwise, issue the DELETE VOLUME command on the  
source server to remove the volume from both the source and target servers.  
ANR4360W  
command: Volume volume name not valid, the type of the volume on target  
server does not match the type on the source server.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was found on both the source and target server, but the type of the volume  
does not match. For example, the volume on the target server is defined in a storage  
pool, but the target server indicates that volume was used for a DATABASE  
BACKUP.  
System Action: The reconciliation process continues.  
User Response: The database on either the source or target server has been  
regressed by either an RESTORE DATABASE operation or some system facility  
external to the server. Investigate the action that caused one or both of the databases  
to be regressed to there current condition. If a newer database image exists for that  
server, consider restoring the server to that point in time. If the condition of the  
database on each server is acceptable, additional actions will have to be taken  
because RECONCILE VOLUMES FIX=YES is unable to correct this situation.  
These actions may have to be performed on one or both servers. Use the QUERY  
570  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VOLHISTORY and QUERY VOLUME commands on both servers to determine the  
volume type on each server. In the case of a volume in the VOLHISTORY, a  
DELETE VOLHISTORY on the appropriate server that will remove the volume on  
that server. In the case of a volume in a storage pool, the DELETE VOLUME  
command on the appropriate server will remove the volume on that server.  
ANR4361W  
command: Volume volume name not valid, the target server has reported  
damage to all or part of the volume.  
Explanation: As the result of a RECONCILE VOLUMES command, the volume  
shown was found on both the source and target server, but the target server has  
reported damage to all or part of the volume.  
System Action: The reconciliation process continues.  
User Response: On the target server, an audit with FIX=NO of the volumes in the  
storage pool used by the source server will indicate what which volume on the  
target server is damaged. This AUDIT VOLUME command may be able to reset the  
damaged indicator in the database if the damage was temporary due to hardware  
problems (for example, dirty tape heads). If the volume on the target server is in a  
primary storage pool that has previously been backed up to a copy storage pool,  
attempt to correct the damage by using the RESTORE STGPOOL command. If  
attempts to correct the damage on the target server fail, an AUDIT VOLUME  
command FIX=YES from the source server will mark as damaged in the source  
server database each file that is inaccessible and those files will not be accessed for  
future operations. If the files are part of an aggregate, the entire aggregate will be  
marked damaged. If a usable copy of the file exists in another storage pool, that  
copy may be accessed for future operations involving the file.  
ANR4362W  
command: Invalid volume volume name deleted from server server name for  
device class device class.  
Explanation: As the result of a RECONCILE VOLUMES command that specified  
FIX=YES, the volume shown whose information is displayed is deleted from the  
target server.  
System Action: The volume is deleted.  
User Response: None.  
ANR4363W  
command: Volume volume name access changed to access mode.  
Explanation: As the result of a RECONCILE VOLUMES command that specified  
FIX=YES, the access mode of the source volume has been changed to the value  
shown.  
System Action: The volume’s access mode is changed.  
Tivoli Storage Manager Messages  
571  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Review any additional messages issued by the RECONCILE  
VOLUMES command and correct the errors that set the volume to unavailable, or  
use the DELETE VOLUME command to remove it from the system.  
ANR4364W  
command: Unable to connect to target server server name.  
Explanation: During processing of indicated command, the source server was  
unable to maintain communications with the shown target server.  
System Action: The command process continues.  
User Response: Check both the source server and the target server for any  
additional messages that might further describe the communications problem.  
ANR4370E  
The source server is not authorized to create volumes on target server server  
name.  
Explanation: The source server has attempted to create a volume on the shown  
target server, but the operation failed because the source server does not have the  
authority to create volumes.  
System Action: The operation fails.  
User Response: If the source server should have permission to create volumes on  
the shown target server, issue the UPDATE SERVER command with  
FORCESYNC=YES to cause the target server to accept volume create operations  
for the source server. Retry the failing operation.  
ANR4371E  
Information on the source server does not match information on target server  
server name.  
Explanation: The source server has determined that information contained on the  
shown target server no longer matches information contained on the source server.  
System Action: The operation fails.  
User Response: Issue the RECONCILE VOLUMES command to determine the  
problem. If possible, correct the problem and retry the failing operation.  
ANR4372E  
The password on the source server does not match the password on target  
server server name.  
Explanation: The source server has attempted to update both the source password  
and the target password. An error occurred that prevented the source server from  
updating the target server. The passwords no longer match.  
System Action: The operation fails.  
572  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: On the target server, issue the UPDATE NODE command to  
change the password. On the source server, issue the UPDATE SERVER command  
to change the password to match the new password on the target server. Retry the  
failing operation.  
ANR4373E  
Session rejected by target server server name, reason: rejection reason.  
Explanation: The source server has attempted to open a session with the shown  
target server. The session was rejected for the indicated reason.  
System Action: The operation fails.  
User Response: Check both the source server and the target server for any  
additional messages that might further describe the reason the session was rejected.  
For a reason of AUTHENTICATION FAILURE, ensure that both the source and  
target servers are using the same password. For a reason of NO RESOURCE,  
ensure that the target server is enabled, has sufficient DB, LOG, and memory  
resource to support the source server session and that the node name of the source  
server is not locked or in use. If this is a routed command, check to make sure that  
the administator id being used to route the command is not locked or in use. For a  
reason of LICENSE FAILURE, ensure that the target server is properly licensed to  
support the source server session. For a reason of DOWN LEVEL, ensure that the  
target server program is a level new enough to support the source server session.  
For a reason of NODE TYPE, the source server is not allowed to establish a session  
with the given target server. The NODETYPE on the target server is CLIENT. The  
NODENAME parameter of the server definition on the source server is incorrect.  
The NODETYPE parameter of the registered node on the target server is incorrect  
and should be NODETYPE=SERVER. For a reason of INTERNAL ERROR, use  
the messages on the target server to determine the problem and contact your service  
representative. Retry the failing operation.  
ANR4374E  
Session failure, source server detected an internal error.  
Explanation: The source server ends the session because an internal logic error is  
detected.  
System Action: The source server ends the session and continues operation.  
User Response: To determine the source of the error, the administrator can  
examine server messages issued prior to this message. The QUERY ACTLOG  
command can be used to view the activity log and search for messages. If the error  
cannot be isolated and resolved, contact your service representative.  
ANR4375E  
Session failure, source server has insufficient memory.  
Explanation: The source server ends the session because sufficient memory  
(virtual memory) is not available.  
Tivoli Storage Manager Messages  
573  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The source server ends the session and continues operation.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR4376E  
ANR4377E  
ANR4378E  
Session failure, target server server name is locked on the source server.  
Explanation: The source server ends the session because shown target server is  
locked from source server access.  
System Action: The source server ends the session and continues operation.  
User Response: Before the source server is permitted to access the target server, a  
properly authorized administrator must unlock the target server.  
Session failure, target server server name is not defined on the source server.  
Explanation: The source server ends the session because shown target server is  
not defined on the source server.  
System Action: The source server ends the session and continues operation.  
User Response: Before the source server is permitted to access the target server,  
the target server must be properly defined.  
For device class device class, the retry of a session with target server server  
name has timed out.  
Explanation: The source server has attempted to re-establish a session with the  
shown target server, but the RETRYPERIOD from the given device class has been  
exceeded.  
System Action: The source server ends the operation.  
User Response: Determine it the target server is having a problem or considering  
increasing the RETRYPERIOD value.  
ANR4379E  
The source server was unable to update the password on target server server  
name.  
Explanation: The source server has attempted to update the target password. An  
error occurred that prevented the source server from updating the target server.  
System Action: The operation fails.  
User Response: On the target server, determine the cause of the problem and  
correct it. It may be necessary for an administrator to correct the passwords with the  
following actions. On the target server, issue the UPDATE NODE command to  
574  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
change the password. On the source server, issue the UPDATE SERVER command  
to change the password to match the new password on the target server. Retry the  
failing operation.  
ANR4380E  
The source server was unable to update the server validation key on target  
server server name.  
Explanation: The source server has attempted to update it’s server validation key  
on the target server. An error occurred that prevented the source server from  
updating the target server.  
System Action: The operation fails.  
User Response: On the target server, determine the cause of the problem and  
correct it. It may be necessary for an administrator to correct the keys with the  
following actions. On the source server, issue the UPDATE SERVER command with  
FORCESYNC=YES to cause an attempt to synchronize the keys on both the source  
and target servers. Retry the failing operation.  
ANR4381E  
The source server was unable to register with target server server name.  
Explanation: The source server has attempted to register with the shown target  
server. An error occurred that prevented the source server from registering with the  
target server.  
System Action: The operation fails.  
User Response: Ask an authorized administrator to submit the request on the use  
of the target server using REGISTER NODE command. Retry the failing operation.  
ANR4382E  
Session failure, policy information from target server server name is incomplete,  
missing policy object.  
Explanation: The source server ends the session because the shown target server  
has provided policy information which is incomplete. The missing policy object is  
shown.  
System Action: The source server ends the session and continues operation.  
User Response: Use the appropriate commands on the target server to complete  
the policy definitions being used by the source server. Retry the failing operation.  
ANR4383E  
Session failure, target server server name has aborted current transaction;  
reason: abort reason.  
Explanation: The source server ends the session because the shown target server  
has aborted the current transaction for the given reason.  
System Action: The source server ends the session and continues operation.  
Tivoli Storage Manager Messages  
575  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check both the source server and the target server for any  
additional messages that might further describe the reason the transaction was  
aborted. Retry the failing operation.  
ANR4384E  
Node node name is not allowed to establish a session as a target server.  
Explanation: The node specified has attempted to establish a session with this  
system and this is not permitted due to the NODETYPE for this node.  
System Action: The operation fails.  
User Response: To allow the specified node to establish a session as a target  
server, the node must be registered with a NODETYPE of SERVER. Or else change  
the node name on the target server to a node name that is allowed to establish a  
session using a node name that was registered with the NODETYPE=SERVER  
parameter specified.  
ANR4385I  
Session retry in progress with target server server name.  
Explanation: The source server is attempting to re-establish a session with the  
shown target server. Session retry processing occurs when the source server has lost  
the connection with a target server and a RETRYPERIOD value is specified,  
System Action: The source server attempts to contact the target server.  
User Response: Determine if the target server is having a problem and considering  
canceling the operation on the source server or correcting the problem with the  
target server.  
ANR4386I  
Session retry was successful for target server server name.  
Explanation: The source server has re-establish a session with the shown target  
server.  
System Action: Source server processing continues.  
User Response: None.  
ANR4387E  
Session session number for node node name (client platform) refused - node name  
not registered as TYPE=CLIENT.  
Explanation: The server refuses a request to start a client session because the  
client node name is not registered as a node of TYPE=CLIENT. This node name is  
already in use either as a server definition as defined by a DEFINE SERVER  
command or else as a node of TYPE=SERVER using the REGISTER NODE  
command.  
System Action: Server operation continues.  
576  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue a QUERY NODE TYPE=SERVER or a QUERY SERVER  
to determine which server definition already is using this node name. This client  
should be registered using the REGISTER NODE TYPE=CLIENT command and  
specify a name that is not in use by any other nodes or server defined to this server.  
ANR4388W  
ANR4389I  
ANR4390E  
No expiration process to cancel.  
Explanation: The CANCEL EXPIRATION command was issued but there were  
no expiration processes currently running.  
System Action: Server operation continues.  
User Response: None.  
Expiration process cancelled.  
Explanation: The CANCEL EXPIRATION command was issued and successfully  
cancelled the current process.  
System Action: Server operation continues.  
User Response: None.  
CANCEL EXPIRATION failed - unable to cancel expiration process.  
Explanation: The CANCEL EXPIRATION command was issued but encountered  
an error. Due to this error, the command was unable to cancel the process.  
System Action: Server operation continues.  
User Response: Issue the command QUERY PROCESS to determine the process  
number for the expiration process and then issue the command CANCEL PROCESS  
for that process number. This will cancel the current expiration process.  
ANR4391I  
Expiration processing node node name, filespace filespace name, domain domain  
name, and management class management class name - for type type files.  
Explanation: Expiration processing is currently evaluating information for the  
node, filespace, domain name, and management class specified for the file type  
indicated.  
System Action: Server operation continues.  
User Response: None.  
ANR4402I  
Database Dump command: Database update activity resumed  
Explanation: Database update activities that were suspended by the database dump  
process are restarted.  
Tivoli Storage Manager Messages  
577  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: None.  
ANR4403I  
ANR4404I  
ANR4405I  
Database Load command: Database dump image is consistent - a database audit  
(AUDITDB) will NOT be required if this load completes successfully.  
Explanation: The database dump that is currently being loaded by the LOADDB  
process is a consistent database image. This process implies that a database audit  
(AUDITDB) will not be required if the load completes successfully.  
System Action: Server database load processing continues.  
User Response: None  
Database Load command: Loaded a consistent dump image - a database audit  
(AUDITDB) is NOT required.  
Explanation: The database dump image loaded by the LOAD command was  
consistent. A database audit (AUDITDB) is not required. The server may be started  
normally.  
System Action: Server database load processing completes.  
User Response: None.  
Database Load command: Loaded an inconsistent dump image - a database  
audit (AUDITDB) IS REQUIRED with FIX=YES.  
Explanation: The database dump image loaded by the LOAD command was not  
consistent. A database audit (AUDITDB) with FIX=YES is required to return the  
database to a consistent state.  
System Action: Server database load processing completes.  
User Response: To check the database for inconsistencies and correct any  
inconsistencies, use the database audit (AUDITDB) utility as described in the  
Administrators Reference.  
ANR4406I  
Audit command: Client option Client option name sequence number option  
sequence number is not a member of an optionset. The option will be deleted.  
Explanation: A database audit process found that the specified client option does  
not have a corresponding optionset. The option is deleted.  
System Action: Audit processing continues.  
User Response: None.  
578  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4407I  
ANR4408I  
ANR4409I  
ANR4410I  
Audit command: Client option Client option name sequence number option  
sequence number is not a member of an optionset.  
Explanation: A database audit process found that the specified client option does  
not have a corresponding optionset. The option is deleted.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Audit command: Client option Client option name sequence number option  
sequence number in optionset optionset name is not a valid option. The option  
will be deleted.  
Explanation: A database audit process found that the specified client option is not  
a valid option. The option is deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: Client option Client option name sequence number option  
sequence number in optionset option set is not a valid option.  
Explanation: A database audit process found that the specified client option is not  
a valid option.  
System Action: Audit processing continues.  
User Response: Reissue the audit command and specify FIX=YES so that the  
error can be corrected.  
Triggered space expansion will be retried in number of seconds seconds.  
Explanation: Because of a problem encountered during a triggered space  
expansion for the data base and/or recovery log, the current expansion stops but will  
be retried after the time period shown.  
System Action: The system waits for the specified period and then retries to  
expand the data base and/or recovery log.  
User Response: If possible, correct the condition that stopped the expansion. If the  
problem persists, contact your service representative.  
Tivoli Storage Manager Messages  
579  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4411I  
Triggered space expansion retry delay ended; checking space trigger criteria.  
Explanation: Because a triggered space expansion had been stopped due to a  
problem, the system waited before retrying. The retry wait period has ended, and the  
system can now retry to expand space for the data base and/or recovery log.  
System Action: Space expansion begins.  
User Response: None.  
ANR4412I  
ANR4413I  
Data Base and Recovery Log Space expansion triggered.  
Explanation: A triggered space expansion had started.  
System Action: Space expansion begins.  
User Response: None.  
Recovery Log Space expansion Is Needed, megabytes needed Megabytes needed.  
Explanation: The recovery log is above the utilization percentage defined in a  
DEFINE SPACETRIGGER LOG command. An expansion of the indicated number  
of megabytes are needed to be above the space trigger utilization value.  
System Action: Space expansion begins if supported on this platform.  
User Response: None.  
ANR4414I  
Data Base Space expansion Is Needed, megabytes needed Megabytes needed.  
Explanation: The data base is above the utilization percentage defined in a  
DEFINE SPACETRIGGER DB command. An expansion of the indicated number of  
megabytes are needed to be above the space trigger utilization value.  
System Action: Space expansion begins if supported on this platform.  
User Response: None.  
ANR4415I  
Data Base and Recovery Log Space Expansion Completed.  
Explanation: A triggered space expansion had completed.  
System Action: Normal operations resume.  
User Response: None.  
580  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4416W  
ANR4417W  
ANR4418W  
Unable to Determine Maximum Number of Data Base Volume Copies, rc=return  
code.  
Explanation: The Data Base Space Trigger was in the processing of expanding the  
data base by creating new data base volumes. In doing so, the maximum number of  
copy volumes for any data base volume is determined. The process of determining  
this value failed.  
System Action: Server operation continues. No additional data base copy volumes  
are created during this data base space expansion.  
User Response: Use the Query DBVOL command to determine if your data base  
volume configuration is satisfactory. You may use the DEFINE DBCOPY command  
to define additional data base volume copies, if necessary.  
Unable to Create Data Base Copy Volume Data Base Copy Volume for volume  
Data Base Volume.  
Explanation: The Data Base Space Trigger was in the processing of expanding the  
data base by creating new data base volumes. In doing so, data base copy volumes  
are created for mirroring. The indicated data base copy volume could not be created  
for the primary data base volume named.  
System Action: Server operation continues. A data base copy volume is not  
created for the indicated primary volume.  
User Response: Use the Query DBVOL command to determine if your data base  
volume configuration is satisfactory. You may use the DEFINE DBCOPY command  
to define additional data base volume copies, if necessary.  
Unable to Define Data Base Copy Volume Data Base Copy Volume for volume  
Data Base Volume.  
Explanation: The Data Base Space Trigger was in the processing of expanding the  
data base by creating new data base volumes. In doing so, data base copy volumes  
are created for mirroring. The indicated data base copy volume was created for the  
primary data base volume named, but could be registered with the server.  
System Action: Server operation continues. A data base copy volumes is not  
registered for the indicated primary volume. The data base copy volume still exists  
on the system.  
User Response: Use the Query DBVOL command to determine if your data base  
volume configuration is satisfactory. You may use the DEFINE DBCOPY command  
to retry the definition of the data base volume copy, if necessary.  
Tivoli Storage Manager Messages  
581  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4419W  
ANR4420W  
ANR4421W  
Unable to Determine Maximum Number of Recovery Log Volume Copies,  
rc=return code.  
Explanation: The Recovery Log Space Trigger was in the processing of expanding  
the recovery log by creating new recovery log volumes. In doing so, the maximum  
number of copy volumes for any recovery log volume is determined. The process of  
determining this value failed.  
System Action: Server operation continues. No additional recovery log copy  
volumes are created during this recovery log space expansion.  
User Response: Use the Query LOGVOL command to determine if your recovery  
log volume configuration is satisfactory. You may use the DEFINE LOGCOPY  
command to define additional recovery log volume copies, if necessary.  
Unable to Create Recovery Log Copy Volume Recovery Log Copy Volume for  
volume Recovery Log Volume.  
Explanation: The Recovery Log Space Trigger was in the processing of expanding  
the recovery log by creating new data base volumes. In doing so, recovery log copy  
volumes are created for mirroring. The indicated recovery log copy volume could  
not be created for the primary recovery log volume named.  
System Action: Server operation continues. A recovery log copy volume is not  
created for the indicated primary volume.  
User Response: Use the Query LOGVOL command to determine if your recovery  
log volume configuration is satisfactory. You may use the DEFINE LOGCOPY  
command to define additional recovery log volume copies, if necessary.  
Unable to Define Recovery Log Copy Volume Recovery Log Copy Volume for  
volume Recovery Log Volume.  
Explanation: The Recovery Log Space Trigger was in the processing of expanding  
the recovery log by creating new recovery log volumes. In doing so, recovery log  
copy volumes are created for mirroring. The indicated recovery log copy volume  
was created for the primary recovery log volume named, but could be registered  
with the server.  
System Action: Server operation continues. A recovery log copy volume is not  
registered for the indicated primary volume. The recovery log copy volume still  
exists on the system.  
User Response: Use the Query LOGVOL command to determine if your recovery  
log volume configuration is satisfactory. You may use the DEFINE LOGCOPY  
command to retry the definition of the recovery log volume copy, if necessary.  
582  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4422I  
AUDITDB: Insufficient database space to optimze audit processing.  
Explanation: A database audit process found that insufficient database space is  
available to optimize audit processing. If the audit can process, it will take much  
longer to complete than if the space was available.  
System Action: Audit processing continues of possible, but may terminate if very  
little space is available.  
User Response: Use the dsmserv extend db command to increase the size of the  
server datbase and restart the database audit function.  
ANR4423I  
AUDITDB: Insufficient database space to continue audit processing.  
Explanation: A database audit process found that insufficient database space is  
available to continue audit processing.  
System Action: Audit processing terminates.  
User Response: Use the dsmserv extend db command to increase the size of the  
server datbase and restart the database audit function.  
ANR4424W  
Data Base has reached Maximum Size in Space Trigger.  
Explanation: The Data Base Space Trigger was specified with a maximum size  
for the data base. That value has been reached for the size of the data base.  
System Action: Server operation continues. No additional data base space  
expansion will occur as a result of the data base space trigger.  
User Response: None. You may review the space trigger settings and use the  
UPDATE SPACETRIGGER DB command to adjust space trigger values.  
ANR4425W  
Recovery Log has reached Maximum Size in Space Trigger.  
Explanation: The Recovery Log Space Trigger was specified with a maximum  
size for the recovery log. That value has been reached for the size of the recovery  
log.  
System Action: Server operation continues. No additional recovery log expansion  
will occur as a result of the recovery log space trigger.  
User Response: None. You may review the space trigger settings and use the  
UPDATE SPACETRIGGER LOG command to adjust space trigger values.  
Tivoli Storage Manager Messages  
583  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4426W  
Recovery Log can no longer be Expanded by the Space Trigger.  
Explanation: The Recovery Log Space Trigger was going to automatically expand  
the recovery log. Expanding the recovery log would cause the recovery log’s size to  
exceed 5GB, which is beyond the server maximum limit for the recovery log.  
System Action: Server operation continues, but the recovery log is not  
automatically expanded. No additional recovery log expansion will occur as a result  
of the recovery log space trigger.  
User Response: None. You may review the space trigger settings and use the  
UPDATE SPACETRIGGER LOG command to adjust space trigger values. You may  
also backup the data base and /or setup a data base backup trigger to cause the data  
base to be backed up more often. Backing up the data base will decrease the  
recovery log utilization and you then use the REDUCE LOG and DELETE  
LOGVOLUME command to decrease the size of the recovery log.  
ANR4427W  
One or more Recovery Log Volumes differ in number of copy volumes.  
Explanation: The Recovery Log Space Trigger was in the processing of expanding  
the recovery log by creating new volumes. . In doing so, copy volumes are created  
for mirroring, and existing volumes are examined for mirroring. One or more  
recovery log volumes was found to have a different number of copy volumes than  
other volumes of the same type. It is recommended that the same number of copy  
volumes be created for each volume of the same type ( data base or log ).  
System Action: Server operation continues.  
User Response: Use the QUERY LOGVOL command to determine if your volume  
configuration is satisfactory. You may use the DEFINE LOGCOPY command to  
define additional copy volumes, if necessary. You may use the DELETE LOGCOPY  
command to delete unnecessary copy volumes.  
ANR4428W  
One or more Data Base Volumes differs in number of copy volumes.  
Explanation: The Data Base Space Trigger was in the processing of expanding the  
data base by creating new volumes. . In doing so, copy volumes are created for  
mirroring, and existing volumes are examined for mirroring. One or more data base  
volumes was found to have a different number of copy volumes than other volumes  
of the same type. It is recommended that the same number of copy volumes be  
created for each volume of the same type ( data base or log ).  
System Action: Server operation continues.  
User Response: Use the Query DBVOL command to determine if your volume  
configuration is satisfactory. You may use the DEFINE DBCOPY command to  
define additional copy volumes, if necessary. You may use the DELETE DBCOPY  
command to delete unnecessary copy volumes.  
584  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4429W  
Unable to Define Recovery Log Volume Recovery Log Volume.  
Explanation: The Recovery Log Space Trigger was in the processing of expanding  
the recovery log by creating new recovery log volumes. The indicated recovery log  
volume was created, but could not be registered with the server.  
System Action: Server operation continues. A recovery log volume is not  
registered with the server. The recovery log copy volume still exists on the system.  
User Response: Use the Query LOGVOL command to determine if your recovery  
log volume configuration is satisfactory. You may use the DEFINE LOGCOPY  
command to retry the definition of the recovery log volume copy, if necessary.  
There will be an additional message in the activity log prior to this message  
indicating the reason for the failure.  
ANR4430W  
Unable to Define Data Base Volume Data Base Volume.  
Explanation: The Data Base Space Trigger was in the processing of expanding the  
data base by creating new data base volumes. The indicated data base volume was  
created, but could not be registered with the server.  
System Action: Server operation continues. A data base volume is not registered  
with the server. The data base volume still exists on the system.  
User Response: Use the Query DBVOL command to determine if your data base  
volume configuration is satisfactory. You may use the DEFINE DBVOLUME  
command for the data base volume named, to retry the definition of the data base  
volume copy, if necessary. There will be an additional message in the activity log  
prior to this message indicating the reason for the failure.  
ANR4431I  
Recovery Log now Eligible for Expansion.  
Explanation: The Recovery Log Space Trigger has previously hit a point where  
expanding the recovery log would have caused the recovery log’s size to exceed  
5GB, which is beyond the server maximum limit for the recovery log. This caused  
automatic recovery log expansion to be halted. The recovery log size has shrunk but  
once again needs expansion and is now eligible for expansion.  
System Action: Server operation continues, and the automatic recovery log  
expansion will proceed.  
User Response: None. None.  
ANR4432W  
Data Base can no longer be Expanded by the Space Trigger.  
Explanation: The Data Base Space Trigger was going to automatically expand the  
data base. Expanding the data base would cause the size of the data base to exceed  
500GB, which is beyond the server maximum limit for the data base.  
Tivoli Storage Manager Messages  
585  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but the data base is not automatically  
expanded. No additional data base expansion will occur as a result of the recovery  
log space trigger until the data base size is less than the maximum size and the  
trigger attributes allow it to be expanded to a size less than the maxium.  
User Response: None. You may review the space trigger settings and use the  
UPDATE SPACETRIGGER DB command to adjust space trigger values. You may  
also reduce the data base size, if possible.  
ANR4433I  
Data Base now Eligible for Expansion.  
Explanation: The Data Base Space Trigger has previously hit a point where  
expanding the data base would have caused the size of the data base to exceed  
500GB, which is beyond the server maximum limit for the data base. This caused  
automatic data base expansion to be halted. The data base size has shrunk or the  
space trigger values have been adjusted to allow expansion.  
System Action: Server operation continues, and automatic data base expansion  
may proceed.  
User Response: None.  
ANR4434E  
Audit command: Password expiration found for unknown client node node name.  
Explanation: A database audit process finds a password expiration period for a  
client node, but the client node is not defined correctly in the server database.  
System Action: Audit processing continues.  
User Response: If the audit command has not been issued with FIX=YES  
specified, reissue the audit function specifying FIX=YES so that the error can be  
corrected.  
ANR4435I  
Audit command: Password expiration period deleted for unknown client node  
node name.  
Explanation: A database audit process finds a password expiration period for a  
client node, but the client node is not defined correctly in the server database.  
Because FIX=YES has been specified for the audit command, the audit function  
deletes the password expiration period.  
System Action: Audit processing continues.  
User Response: None.  
586  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4436E  
Audit command: Invalid password expiration password expiration period for  
client node node name.  
Explanation: A database audit process finds an invalid password expiration period  
for a client node.  
System Action: Audit processing continues.  
User Response: If the audit command has not been issued with FIX=YES  
specified, reissue the audit function specifying FIX=YES so that the error can be  
corrected.  
ANR4437I  
Audit command: Invalid password expiration period password expiration period  
deleted for client node node name.  
Explanation: A database audit process finds an invalid password expiration period  
for a client node. Because FIX=YES has been specified for the audit command, the  
audit function deletes the password expiration period, causing the default, global  
password expiration period to take effect for the client node.  
System Action: Audit processing continues.  
User Response: After the AUDIT command completes, use the QUERY NODE  
command to examine the node that was updated. Use the UPDATE NODE  
command to set the correct password expiration period for the node.  
ANR4438E  
Audit command: Password expiration found for unknown administrator  
administrator name.  
Explanation: A database audit process finds a password expiration period for an  
administrator, but the administrator is not defined correctly in the server database.  
System Action: Audit processing continues.  
User Response: If the audit command has not been issued with FIX=YES  
specified, reissue the audit function specifying FIX=YES so that the error can be  
corrected.  
ANR4439I  
Audit command: Password expiration period deleted for unknown administrator  
administrator name.  
Explanation: A database audit process finds a password expiration period for an  
administrator, but the administrator is not defined correctly in the server database.  
Because FIX=YES has been specified for the audit command, the audit function  
deletes the password expiration period.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
587  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4440E  
Audit command: Invalid password expiration password expiration period for  
administrator administrator name.  
Explanation: A database audit process finds an invalid password expiration period  
for an administrator.  
System Action: Audit processing continues.  
User Response: If the audit command has not been issued with FIX=YES  
specified, reissue the audit function specifying FIX=YES so that the error can be  
corrected.  
ANR4441I  
Audit command: Invalid password expiration period password expiration period  
deleted for administrator administrator name.  
Explanation: A database audit process finds an invalid password expiration period  
for an administrator. Because FIX=YES has been specified for the audit command,  
the audit function deletes the password expiration period, causing the default, global  
password expiration period to take effect for the administrator.  
System Action: Audit processing continues.  
User Response: After the AUDIT command completes, use the QUERY ADMIN  
command to examine the administrator that was updated. Use the UPDATE ADMIN  
command to set the correct password expiration period for the administrator.  
ANR4442E  
Audit command: Extended attribute extended attribute type is not a valid  
attribute type.  
Explanation: A database audit process finds an extended attribute type that is not  
supported.  
System Action: Audit processing continues.  
User Response: If the audit command has not been issued with FIX=YES  
specified, reissue the audit function specifying FIX=YES so that the error can be  
corrected.  
ANR4443I  
Audit command: Invalid extended attribute extended attribute type has been  
deleted.  
Explanation: A database audit process finds an extended attribute type that is not  
supported. Because FIX=YES has been specified for the audit command, the audit  
function deletes extended attribute.  
System Action: Audit processing continues.  
User Response: None.  
588  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4500I  
Writing sequential volume history information to defined files.  
Explanation: The server is updating all sequential volume history files defined in  
the server options file with information on sequential volume usage information.  
The files updated are those specified with the VOLUMEHISTORY option in the  
server options file.  
System Action: Server operation continues.  
User Response: None.  
ANR4501I  
Sequential volume history information successfully written to file name.  
Explanation: The server is updating all sequential volume history files defined in  
the server options file with information on sequential volume usage information.  
Volume history information was successfully written to the file specified.  
System Action: Server operation continues.  
User Response: None.  
ANR4502W  
No files have been defined for automatically storing sequential volume history  
information.  
Explanation: The server is attempting to update all sequential volume history files  
defined in the server options file with information on sequential volume usage  
information. Because no files were configured for receiving this information, the  
automatic operation fails.  
System Action: Server operation continues.  
User Response: To have the server automatically record sequential volume history  
information to assist in server recovery, use the VOLUMEHISTORY option in the  
server options file to specify where history information should be written. If you  
update the options file, restart the server.  
ANR4510E  
Server could not write sequential volume history information to volume history  
file name.  
Explanation: While attempting to write sequential volume history information to  
defined history files, the server could not write to the file name specified.  
System Action: The server does not write volume history information to the file  
specified  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated and that there is sufficient space in the  
file system for the file. On MVS, make sure that the data set has been allocated and  
Tivoli Storage Manager Messages  
589  
Download from Www.Somanuals.com. All Manuals Search And Download.  
that the server has authority to write to the data set. After the problem has been  
corrected, use the BACKUP VOLHISTORY command to write sequential volume  
history information to the file.  
ANR4511E  
Volume history file volume history file name could not be opened.  
Explanation: While attempting to write sequential volume history information to  
or read information from defined history files, the server cannot open the file name  
specified.  
System Action: The server does not write volume history information to or read  
volume history information from the file specified  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated and that there is sufficient space in the  
file system for the file. On MVS, make sure that the data set has been allocated and  
that the server has authority to write to the data set.  
ANR4512E  
A database transaction failure was encountered in processing sequential volume  
history information.  
Explanation: While attempting to process sequential volume history information,  
the server encountered a database transaction error.  
System Action: The operation fails. Usage for a sequential volume was not  
properly recorded for later reference.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. If this does not resolve the  
problem, contact your support representative.  
ANR4513E  
A database lock conflict was encountered in processing sequential volume  
history information.  
Explanation: While attempting to process sequential volume history information,  
the server encountered a database locking conflict.  
System Action: The operation fails. This usually means that usage for a sequential  
volume was not properly recorded for later reference  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. If this does not resolve the  
problem, contact your support representative.  
590  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4514E  
ANR4515E  
ANR4516E  
Sufficient database space is not available for the server while processing  
sequential volume history information.  
Explanation: While attempting to process sequential volume history information,  
the server found that sufficient database space was not available for updates.  
System Action: The operation fails. Usage for a sequential volume was not  
properly recorded for later reference.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes by using the DEFINE  
DBVOLUME command, and extend the size of the database by using the EXTEND  
DB command.  
Sufficient recovery log space is not available for the server while processing  
sequential volume history information.  
Explanation: While attempting to process sequential volume history information,  
the server finds that sufficient recovery log space is not available for updates.  
System Action: The operation fails. Usage for a sequential volume was not  
properly recorded for later reference.  
User Response: To increase the amount of database space available to the server,  
an authorized administrator can add database volumes by using the DEFINE  
LOGVOLUME command, and extend the size of the database by using the  
EXTEND LOG command.  
Server could not read sequential volume history information from any defined  
files.  
Explanation: While attempting to read sequential volume history information from  
defined history files, the server finds that it cannot open any of the files defined in  
the server options file.  
System Action: The server does not read volume history information. If the  
current server task requires this information, the task ends.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to read from the defined volume history files. If you are doing a  
database restore, issue RESTORE DB DEVCLASS=VOL.  
Tivoli Storage Manager Messages  
591  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4517E  
No files have been defined for storing sequential volume history information -  
information cannot be read.  
Explanation: The server is attempting to read from at least one of the volume  
history files defined in the server options file. Since no files were defined for this  
information the read operation fails.  
System Action: Server operation ends.  
User Response: You can restore the database specifying the volume names for  
each restore operation (in order) up to the desired point-in-time. If a volume history  
file is available, specify its name in the server options file and retry the operation.  
ANR4518E  
Volume history file file name line line number does not have the proper format -  
read operation fails.  
Explanation: The server is attempting to read from a volume history file and  
encounters a record that does not have the proper format.  
System Action: Server operation terminates.  
User Response: Examine the file specified to determine if the invalid record can  
be located and corrected. If the file is corrupted or does not contain valid volume  
history entries, it cannot be used for the desired operation.  
ANR4549I  
Database dump command: A database dump is already in progress.  
Explanation: This message is issued in response to a database dump command  
and indicates that a database dump cannot be started because a dump is already in  
progress.  
System Action: Server operation continues. The requested database dump is not  
started.  
User Response: Only one database dump can be started at one time. Use the  
QUERY PROCESS command to monitor the dump that is in progress. When  
completed, issue the database dump command to start another database dump if  
required.  
ANR4550I  
Full database backup (process process ID) complete, number of database pages  
pages copied.  
Explanation: A full database backup process has completed. The output volumes  
used in this backup may be used during a database restore operation.  
System Action: None.  
User Response: None.  
592  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4551I  
Incremental database backup (process process ID) complete, number of database  
pages pages copied.  
Explanation: An incremental database backup process has completed. The output  
volumes used in this backup may be used in conjunction with any preceding  
volumes in the backup series during a database restore operation.  
System Action: None.  
User Response: None.  
ANR4552I  
Full database backup triggered; started as process process ID.  
Explanation: A background process, triggered by the LOGFULLPCT parameter on  
a DEFINE DBBACKUPTRIGGER command, was started to back up the full  
contents of the database. The full database backup process is assigned the process  
ID shown.  
System Action: The database backup process starts and server operation continues.  
User Response: The administrator may query the status of the database backup  
process by using the QUERY PROCESS command, or cancel the process by using  
the CANCEL PROCESS command.  
ANR4553I  
Incremental database backup triggered; started as process process ID.  
Explanation: A background process, triggered by the LOGFULLPCT parameter on  
a DEFINE DBBACKUPTRIGGER command, was started to incrementally back up  
the contents of the database. The incremental database backup process was assigned  
the process ID shown.  
System Action: The database backup process starts and server operation continues.  
User Response: The administrator may query the status of the database backup  
process by using the QUERY PROCESS command, or cancel the process by using  
the CANCEL PROCESS command.  
ANR4554I  
Backed up number of pages backed up of number of pages to back up in current  
operation database pages.  
Explanation: Periodically, during a database backup, the server displays the  
number of pages backed up.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
593  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4555I  
Database backup process process ID canceled.  
Explanation: The database backup process was canceled by an administrator with  
the CANCEL PROCESS command.  
System Action: The database backup process is ended.  
User Response: None.  
ANR4556W  
Attention: the database backup operation did not free sufficient recovery log  
space to lower utilization below the database backup trigger. The recovery log  
size may need to be increased.  
Explanation: A database backup process has completed. The server is running in  
roll-forward mode and the recovery log utilization remains above that specified in  
the database backup trigger.  
System Action: A database backup operation will be triggered. Unless this  
situation is corrected, database backups will be triggered rapidly, one after the other.  
User Response: If a database backup operation does not free up enough recovery  
log space to reset utilization below the database backup trigger, the recovery log  
needs to be extended or the database backup trigger updated to a higher log full  
percentage.  
ANR4560I  
Triggered database backup will be retried in number of seconds seconds.  
Explanation: Because of a problem encountered during a triggered database  
backup, the current backup stops but will be retried after the time period shown.  
System Action: The system waits for the specified period and then retries a  
database backup.  
User Response: If possible, correct the condition that stopped the database backup.  
If the problem persists, contact your service representative.  
ANR4561I  
Triggered database backup retry delay ended; checking database backup  
trigger criteria.  
Explanation: Because a triggered database backup had been stopped due to a  
problem, the system waited before retrying. The retry wait period has ended, and the  
system can now retry the database backup.  
System Action: Database backup begins.  
User Response: None.  
594  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4562I  
Database backup criteria is no longer met; triggered database backup canceled.  
Explanation: Because a triggered database backup had been stopped due to a  
problem, the system waited before retrying. The retry wait period has ended, and the  
system determined that the criteria for triggering a database backup was no longer  
met.  
System Action: The system waits until the database backup trigger criteria is met  
before triggering another database backup.  
User Response: None.  
ANR4563I  
Unable to trigger database backup - a database define, delete, extend, reduce,  
or backup operation is already in progress.  
Explanation: A database backup was triggered, but a command that is modifying  
or backing up the database is already active.  
System Action: The backup stops and the server waits for the retry period to  
expire and then tries the database backup again.  
User Response: None.  
ANR4564I  
Unable to trigger database backup - sufficient memory is not available.  
Explanation: A database backup was triggered, but there is not enough server  
memory available.  
System Action: The backup stops and the server waits for the retry period to  
expire and then tries the database backup again.  
User Response: If necessary, make more memory available to the server.  
ANR4565E  
Unable to trigger database backup - thread resource not available.  
Explanation: A database backup was triggered, but the server cannot start a thread  
for the backup process.  
System Action: The backup stops and the server waits for the retry period to  
expire and then tries the database backup again.  
User Response: If the error persists, it may indicate a shortage of server memory.  
Allocate additional server memory.  
ANR4570E  
Database backup/restore terminated - device class device class name not  
defined.  
Explanation: During database backup or restore processing, an error occurred  
because the specified device class is not defined.  
Tivoli Storage Manager Messages  
595  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is terminated.  
User Response: For database backup, make sure the specified device class is  
defined. For database restore processing, make sure the device class has a definition  
in a device configuration file that is pointed to in the server options file.  
ANR4571E  
Database backup/restore terminated - insufficient number of mount points  
available for removable media.  
Explanation: During database backup or restore, the server cannot allocate  
sufficient mount points for the volumes required.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is ended.  
User Response: For database backup, make more mount points available if  
necessary. For database restore processing, make sure the device class has sufficient  
mount points defined in the device configuration information file that is pointed to  
in the server options file.  
ANR4572E  
Database restore terminated - excessive read errors encountered.  
Explanation: During database restore, read errors occur that prevent the restore  
from continuing.  
System Action: Database restore processing stops.  
User Response: Use a different device for the restore operation. If the problem  
persists, contact your service representative.  
ANR4573E  
Database backup terminated - excessive write errors encountered.  
Explanation: During database backup, write errors occur that prevent the backup  
from continuing.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again.  
User Response: If possible, determine and correct the cause of the write errors. If  
the problem cannot be corrected, contact your service representative.  
596  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4574E  
Database backup/restore terminated - data transfer interrupted.  
Explanation: During a database backup or restore operation, a data transfer  
operation has been interrupted and cannot be continued.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is ended.  
User Response: If possible, determine and correct the cause of the interruption. If  
the problem cannot be corrected, contact your service representative.  
ANR4575E  
Database backup/restore terminated - sufficient recovery log space is not  
available.  
Explanation: During a database backup or restore operation, the server runs out of  
recovery log space.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is terminated.  
User Response: For database backup, make more server recovery log space  
available, if necessary. For database restore, contact your service representative.  
ANR4576E  
Database backup/restore terminated - sufficient database space is not available.  
Explanation: During a database backup or restore operation, the server runs out of  
database space.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. The database  
restore process attempts to set the database capacity to the required capacity to hold  
the database being restored. If this fails, the restore operation is ended.  
User Response: For database backup, make more server database space available,  
if necessary. For database restore, make sure that the size of the online database is  
at least the same capacity as the database being restored.  
Tivoli Storage Manager Messages  
597  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4577E  
Database backup terminated - volume already in use.  
Explanation: During a database backup operation, a volume cannot be used  
because it is already defined in a storage pool, or has been previously used by an  
export, a database dump, or a database backup operation (as recorded in the volume  
history) or is in use by another process.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again.  
User Response: Specify a volume that is not in use or defined in a storage pool,  
and that has not been previously used for an export, a database dump, or a database  
backup operation as recorded in the server volume history information. The QUERY  
VOLUME command may be used to display the names of volumes that are defined  
to server storage pools. The QUERY VOLHISTORY command may be used to  
display the names of volumes that have been used for export, database dump, or  
database backup operations.  
ANR4578E  
Database backup/restore terminated - required volume was not mounted.  
Explanation: During a database backup or restore operation, a required volume  
cannot be mounted, because the mount request was canceled.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is terminated.  
User Response: Issue the command again or wait for the server to retry the  
backup and make sure the necessary volumes are accessible. If you are restoring a  
database to a given date or doing a roll-forward restore, restart the entire restore  
operation. If you are restoring a single database backup with COMMIT=NO, reissue  
the restore command. If you are restoring a database backup with COMMIT=YES,  
restore the complete backup series from the beginning.  
ANR4579E  
Database backup/restore terminated - thread resource not available.  
Explanation: During a database backup or restore operation, the server cannot  
start a thread for the backup process.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is terminated.  
598  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Retry the command or wait for the server to retry the backup if it  
was started by the backup trigger. If the error persists, it may indicate a shortage of  
server memory.  
ANR4580E  
Database backup/restore terminated - insufficient memory available.  
Explanation: During a database backup or restore operation, there was not enough  
server memory available.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is terminated.  
User Response: If necessary, make more memory available to the server.  
ANR4581W  
Database backup/restore terminated - internal server error detected.  
Explanation: During a database backup or restore operation, the server encounters  
an internal error.  
System Action: If the database backup was started with the BACKUP DB  
command, the database backup is ended and server operation continues. If the  
database backup was triggered automatically, the backup stops and the server waits  
for the retry period to expire and then tries the database backup again. A database  
restore is terminated.  
User Response: Contact your service representative.  
ANR4582E  
Database restore terminated - volume cannot be used.  
Explanation: During a database restore operation, a volume has been mounted but  
cannot be used.  
System Action: The restore operation is terminated.  
User Response: If a volume list was specified on the command, make sure the  
correct volume is being specified and mounted. If no volume list was specified,  
contact your service representative.  
ANR4583E  
Database backup terminated - output media full and scratch media could not  
be mounted.  
Explanation: During a database backup operation, an out-of-space condition  
occurred writing to the sequential media, and a scratch volume cannot be mounted.  
System Action: The database backup is ended and server operation continues.  
Tivoli Storage Manager Messages  
599  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command and specify additional volume names on the  
command, or specify SCRATCH=YES.  
ANR4584E  
Database restore terminated - incomplete input volume list.  
Explanation: The list of volumes needed for the restore operation was incomplete.  
At least one volume needed for the restore operation is missing from the end of the  
list.  
System Action: The database restore is terminated.  
User Response: If you are using a DSMSERV RESTORE DB command with the  
VOLUMENAMES parameter specified, verify that all the volumes within a  
database backup operation are included in the list. Ensure that all the volume names  
are specified in the correct sequential order. For a restore with COMMIT=NO,  
reissue the last restore command. For a restore with COMMIT=YES, restart the  
restore from the beginning of the full backup. If you are using a DSMSERV  
RESTORE DB command with the TODATE parameter specified, the server created  
a list of volumes needed for the restore operation. Examine the volume history files  
to try to determine the error or use a different volume history file if available. You  
can also restore the database by specifying the volume names for each restore  
operation up to the desired point in time.  
ANR4590I  
Backup type backup series backup series number operation backup operation in  
series stream backup stream within operation (always 1) sequence backup volume  
sequence number in operation taken on date at time.  
Explanation: During a DSMSERV DISPLAY DBBACKUPVOL command, the  
server displays the necessary information about a backup volume.  
System Action: Processing continues for all volumes in the given volume list.  
User Response: You can use this information to create a list of volumes for a  
database restore when a volume history backup file is not available.  
ANR4600I  
Processing volume history file file name.  
Explanation: During a DSMSERV RESTORE DB command with the TODATE  
parameter specified, the server is processing the listed file in order to build a list of  
volumes needed for the restore operation.  
System Action: None.  
User Response: None.  
600  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4601E  
Incomplete volume list found for TODATE date time - retrying.  
Explanation: During a DSMSERV RESTORE DB command with the TODATE  
parameter specified, the server created a list of volumes needed for the restore  
operation, but the list was incomplete.  
System Action: The server tries to build the list again using a different volume  
history file specified in the server options file. If no other volume history files are  
available, the server stops processing.  
User Response: If the problem persists, examine the volume history files to try  
and determine the error. You can also restore the database by specifying the volume  
names for each restore operation up to the desired point in time.  
ANR4602E  
No volumes found for TODATE date time.  
Explanation: No volumes were found in the volume history files that meet the  
date and time parameters specified.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid date and time.  
ANR4610E  
ANR4611E  
Database volume DB volume name not found in current configuration.  
Explanation: The command specified the name of a nonexistent database volume.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid database volume name.  
Unable to restore database and roll forward updates - log mode was not  
previously set to ROLLFORWARD.  
Explanation: The command specified that the database be restored and all updates  
rolled forward to the most current state. This process cannot be accomplished  
because the server recovery log mode was not set to ROLLFORWARD; therefore,  
no update information exists.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a point in time  
(TODATE/TOTIME) for restore.  
ANR4612E  
Unable to restore database and roll forward updates.  
Explanation: The command specified that the database be restored and all updates  
rolled forward to the most current state. This process cannot be accomplished  
Tivoli Storage Manager Messages  
601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
because the internal list of volumes for the most recent full/incremental backup  
series is not available. Possible reasons include:  
No full backup was taken after setting the recovery log mode to  
ROLLFORWARD with a SET LOGMODE command.  
Only snapshot database backups were created.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a point in time  
(TODATE/TOTIME) for restore.  
ANR4619I  
Snapshot database backup series snapshot database backup series using device  
class device class.  
Explanation: The device class used for the snapshot database backup is shown.  
System Action: None.  
User Response: None.  
ANR4620I  
Database backup series Backup series operation backup operation device class  
device class.  
Explanation: The device class used for the backup is shown.  
System Action: None.  
User Response: None.  
ANR4621I  
ANR4622I  
Database backup device class device class.  
Explanation: The device class for the backup is shown.  
System Action: None.  
User Response: None.  
Volume volume sequence number in backup operation: volume name.  
Explanation: The volume sequence and name for a full or an incremental database  
backup are shown.  
System Action: None.  
User Response: None.  
602  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4623I  
Stream stream number in backup operation volume volume sequence number in  
backup stream: Volume name.  
Explanation: The stream number, volume sequence and name for a full or an  
incremental database backup are shown.  
System Action: None.  
User Response: None.  
ANR4630I  
Starting point-in-time database restore (commit).  
Explanation: A point-in-time database restore with a specified list of volumes has  
started. When this restore is complete, the database will be committed to the point  
in time of this backup.  
System Action: None.  
User Response: If you inadvertently specified COMMIT=YES, restart the restore  
process from the beginning, starting with restoring the full backup (backup  
operation 0).  
ANR4631I  
Point-in-time database restore (commit) complete, restore date date time.  
Explanation: A point-in-time database restore with a specified list of volumes is  
complete. The date shown is the date to which the database has been restored.  
System Action: None.  
User Response: None.  
ANR4632I  
Starting point-in-time database restore (no commit).  
Explanation: A point-in-time database restore with a specified list of volumes has  
started. When this restore is complete, the database will not yet be usable.  
System Action: None.  
User Response: To complete a database restore where a volume list is specified,  
specify COMMIT=YES on the command when restoring the last set of backup  
volumes. If you forgot to specify COMMIT=YES on the command, issue the last  
restore command again with COMMIT=YES.  
ANR4633I  
Point-in-time database restore (no commit) complete.  
Explanation: A point-in-time database restore with a specified list of volumes is  
complete. The database is not yet usable.  
System Action: None.  
Tivoli Storage Manager Messages  
603  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: To complete a database restore where a volume list is specified,  
specify COMMIT=YES on the command when restoring the last set of backup  
volumes. If you forgot to specify COMMIT=YES on the command, issue the last  
restore command again with COMMIT=YES.  
ANR4634I  
Starting point-in-time database restore to date date time.  
Explanation: A point-in-time database restore with the TODATE parameter  
specified has begun. When this restore is complete, the database will be committed  
to the point in time of this backup.  
System Action: None.  
User Response: None.  
ANR4635I  
Point-in-time database restore complete, restore date date time.  
Explanation: A point-in-time database restore with the TODATE parameter  
specified has completed. The database is committed to the point in time of this  
backup, which may be different than the TODATE specified. If this is the case, an  
additional message will be displayed.  
System Action: None.  
User Response: None.  
ANR4636I  
Starting roll-forward database restore.  
Explanation: A roll-forward database restore has begun. When this restore is  
complete, the database will be returned to its most recent state.  
System Action: None.  
User Response: None.  
ANR4637I  
Roll-forward database restore complete.  
Explanation: A roll-forward database restore has ended. All database backups in  
the most current backup series have been restored, and all updates to the database  
since the most recent backup have been rolled forward. The database has been  
returned to its most recent state.  
System Action: None.  
User Response: None.  
604  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4638I  
ANR4639I  
ANR4640I  
Restore of backup series backup series number operation backup operation in  
series in progress.  
Explanation: During a DSMSERV RESTORE DB, the server displays the backup  
series and operation currently being restored.  
System Action: None.  
User Response: None.  
Restored number of pages restored of number of pages to restore from current  
backup operation database pages.  
Explanation: Periodically, during a DSMSERV RESTORE DB, the server displays  
the number of pages restored from the current backup being restored.  
System Action: None.  
User Response: None.  
Restored number of database pages pages from backup series backup series  
number operation backup operation in series.  
Explanation: At the end of each restored backup, the server displays the number  
of database pages restored.  
System Action: None.  
User Response: None.  
ANR4641I  
Sequential media log redo pass in progress.  
Explanation: During a DSMSERV RESTORE DB, the process of committing  
incomplete database updates has begun.  
System Action: None.  
User Response: None.  
ANR4642I  
Sequential media log undo pass in progress.  
Explanation: During a DSMSERV RESTORE DB, the process of rolling back  
incomplete transactions has begun.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
605  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4643I  
Processed number of log records log records.  
Explanation: Periodically, during the commit of a point-in-time restore or while  
rolling forward updates during a roll forward restore, the server displays the number  
of log records processed.  
System Action: None.  
User Response: None.  
ANR4644I  
A full backup will be required for the next database backup operation.  
Explanation: During a point-in-time restore of a database, this message is  
displayed to notify the administrator that the next database backup taken during  
normal operation must be a full backup. This process is normal for point-in-time  
database restores.  
System Action: None.  
User Response: At the next server restart, do a full database backup. A full  
database backup is started automatically if a DBBACKUPTRIGGER is defined.  
ANR4645I  
The restore date reflects the most recent backup available up to the specified  
TODATE.  
Explanation: During a DSMSERV RESTORE DB with the TODATE parameter,  
the date of the restored backup was not identical to the date specified on the  
command. The backup series that was restored is the most recent backup series up  
to and including the specified date.  
System Action: None.  
User Response: Make sure the date of the restored database is satisfactory. If it is  
not, restore the database again by specifying a different TODATE or by restoring  
individual database backups.  
ANR4646I  
Database capacity required for restore is number of megabytes megabytes.  
Explanation: During a point-in-time restore of a database, the size of the database  
being restored is displayed. The available capacity of the online database volumes  
must be at least this size.  
System Action: None.  
User Response: None.  
606  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4647I  
Database available capacity is number of megabytes megabytes.  
Explanation: During a point-in-time restore of a database, the available capacity  
of the online database volumes is displayed. This capacity must be as large as the  
size of the database being restored.  
System Action: If the available capacity of the online database volumes is not at  
least this size, the restore cannot continue.  
User Response: If the available capacity of the online database is not sufficient,  
reinstall the server with the required database size, and try the restore operation  
again.  
ANR4648I  
Extending database assigned capacity to number of megabytes megabytes.  
Explanation: During a point-in-time restore of a database, the assigned capacity of  
the online database is smaller than that of the database being restored. However, the  
available capacity of the online database volumes is sufficient for restore.  
System Action: The assigned capacity of the online database is extended to the  
size required for restore.  
User Response: None.  
ANR4649I  
Reducing database assigned capacity to number of megabytes megabytes.  
Explanation: During a point-in-time restore of a database, the assigned capacity of  
the online database is larger than that of the database being restored.  
System Action: The assigned capacity of the online database is reduced to the size  
required for restore.  
User Response: None.  
ANR4650E  
Restore of backup series current series operation current operation is not in  
sequence; last restored backup was series previous series operation previous  
operation.  
Explanation: During a DSMSERV RESTORE DB, a backup volume was mounted  
that is not in the correct sequence.  
System Action: The database restore is terminated.  
User Response: Ensure volume names are specified in the correct sequential order.  
For a restore with COMMIT=NO, reissue the last restore command. For a restore  
with COMMIT=YES, restart the restore from the beginning of the full backup.  
Tivoli Storage Manager Messages  
607  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4651E  
Restore of backup series current series operation current operation is not in  
sequence; backup is part of another log epoch.  
Explanation: During a DSMSERV RESTORE DB, a backup volume was mounted  
that is not in the correct sequence. The current backup operation cannot be restored  
in this series because it belongs to the same backup series from another point in  
time.  
System Action: The database restore is terminated.  
User Response: Restart the database restore from the beginning of the full backup.  
Omit all backups from the offending backup and later from the restore.  
ANR4657E  
SNMP: Failed to connect to server at address address, port port.  
Explanation: The SNMP client was attempting to run a session with the server at  
the indicated address and port number in response to an SNMP Get Request, which  
causes a Server Script to be run. The subagent failed to connect to the server.  
System Action: The SNMP subagent ends this attempt to run the script and  
continues operation.  
User Response: Ensure that the indicated server is up and able to initiate admin  
clients using the TCP/IP protocol.  
ANR4659E  
ANR4660I  
ANR4661E  
SNMP: Communications failure: bad verb received (verb type).  
Explanation: The SNMP client encountered an invalid communications verb  
during a session with the server and is not able to continue processing the session.  
System Action: The SNMP session ends and subagent operation continues.  
User Response: Contact your service representative.  
Connected to SNMP subagent at SNMP subagent address on port port number.  
Explanation: The server has successfully connected to the SNMP subagent at the  
indicated address and port.  
System Action: The server will now register with the subagent.  
User Response: None.  
SNMP communication with the subagent failed because a thread resource was  
not available.  
Explanation: The server could not continue with SNMP communication to the  
SNMP subagent because sufficient memory is not available for starting additional  
processes on the server.  
608  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server discontinues SNMP processing and server operation  
continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR4662W  
Failure sending message to SNMP subagent.  
Explanation: The server experienced an error return code from TCP/IP while  
sending to the SNMP subagent. This message is also issued when the SNMP  
subagent has an error sending a verb to the server when acting as an SNMP client.  
This may be a normal event if either side of the connection is abruptly ended, as in  
the case of terminating the subagent program. The error is reflected in another  
message for TCP/IP which further describes the error.  
System Action: The session is ended. Server operation continues. If a message is  
being forwarded to an SNMP managing node, the message is not sent. If a heartbeat  
message was being sent to the subagent, this heartbeat message is lost and the  
server attempts to re-start its session with the SNMP subagent.  
User Response: If the session is ended as a result of intentionally stopping either  
the subagent, no response is required. Otherwise, ensure that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use.  
ANR4663W  
Failure receiving message from SNMP subagent.  
Explanation: The server experienced an error return code from TCP/IP while  
receiving data from the SNMP subagent. This may be a normal event if either side  
of the connection is abruptly ended, as in the case of terminating the subagent  
program. The error is reflected in another message for TCP/IP which further  
describes the error.  
System Action: The session is ended. Server operation continues. If a heartbeat  
message was being sent to the subagent, this heartbeat message is lost and the  
server attempts to re-start its session with the SNMP subagent. If the server was  
attempting to register to the SNMP subagent, heartbeat messaging will be disabled  
until the server is re-started.  
User Response: If the session is ended as a result of intentionally stopping either  
the subagent, no response is required. Otherwise, ensure that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use.  
Tivoli Storage Manager Messages  
609  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4664W  
ANR4665W  
ANR4666W  
Failure in registering with SNMP subagent.  
Explanation: The server experienced a problem while attempting to register with  
the SNMP subagent. This may be due to problems with communication or the  
SNMP subagent being unavailable.  
System Action: Heartbeat messaging will be disabled until the server is re-started.  
User Response: Ensure that the subagent is running and that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use.  
Failure re-trying registration with SNMP subagent.  
Explanation: The server experienced a problem while attempting to re-register  
with the SNMP subagent after losing contact. This may be due to problems with  
communication or the SNMP subagent being unavailable.  
System Action: Registration is re-tried for a number of attempts before giving up.  
User Response: Ensure that the subagent is running and that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use.  
Failure sending heartbeat message to SNMP subagent.  
Explanation: The server experienced a problem while attempting to send a  
heartbeat message to the SNMP subagent. This may be due to problems with  
communication or the SNMP subagent being unavailable.  
System Action: The server will attempt to contact the SNMP subagent again and  
re-synchronize.  
User Response: Ensure that the subagent is running and that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use.  
ANR4667W  
Failure re-trying heartbeat message to SNMP subagent.  
Explanation: The server experienced a problem while attempting to send a  
heartbeat message to the SNMP subagent. This may be due to problems with  
communication or the SNMP subagent being unavailable.  
System Action: The server attempted to contact the SNMP subagent again and  
re-synchronize, but this too failed. Heartbeat functions are disabled until the server  
is re-started.  
610  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the subagent is running and that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use. Re-start the server if the heartbeat function is required.  
ANR4668I  
Connection successfully re-established with SNMP subagent.  
Explanation: The server experienced a problem while attempting to send a  
heartbeat message to the SNMP subagent.  
System Action: The server was able to successfully resynchronize with the SNMP  
subagent.  
User Response: None.  
ANR4669W  
Heartbeat message was not accepted by SNMP subagent.  
Explanation: The server experienced a problem while attempting to send a  
heartbeat message to the SNMP subagent. The SNMP subagent was unable to accept  
the heartbeat message. If the subagent was stopped and re-started, this is a normal  
message.  
System Action: The server will attempt to contact the SNMP subagent again and  
re-synchronize.  
User Response: Ensure that the subagent is running and that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use.  
ANR4670W  
Failure in opening session with SNMP subagent.  
Explanation: The server experienced a problem while attempting to open a session  
with the SNMP subagent.  
System Action: Processing continues. Heartbeat and message forwarding function  
will not be available.  
User Response: Ensure that the subagent is running and that the TCP/IP protocol  
stack is functioning by using the tools that come with the particular TCP/IP suite on  
the platform in use. If heartbeat and message forwarding functions are required,  
re-start the server.  
ANR4671W  
SNMP subagent did not accept registration of this server.  
Explanation: The server experienced a problem while attempting to open a session  
with the SNMP subagent. The subagent is available but disallowed registration by  
this server.  
System Action: Processing continues. Heartbeat and message forwarding function  
will not be available.  
Tivoli Storage Manager Messages  
611  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: It may be necessary to stop the subagent and re-start it. Then stop  
the server and re-start it if heartbeat and message forwarding functions are required.  
ANR4672W  
SNMP message forwarding to the SNMP subagent was not started because a  
thread resource was not available.  
Explanation: The server could not continue with SNMP communication to the  
SNMP subagent for message forwarding because sufficient memory is not available  
for starting additional processes on the server.  
System Action: The server discontinues SNMP message processing and server  
operation continues.  
User Response: Allocate additional storage to the server. For details, issue HELP  
MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR4673E  
Insufficient memory for subagent initialization (the portion of initialization where  
the allocation of memory failed).  
Explanation: The SNMP subagent could not initialize due to the inability to  
obtain the required memory.  
System Action: Initialization of the subagent fails.  
User Response: Allocate additonal storage to the subagent.  
ANR4674E  
Error starting DPI thread - Return code: Return code received from called  
routine.  
Explanation: The SNMP subagent could not start the DPI thread.  
System Action: Initialization of the subagent fails.  
User Response: Contact your service representative.  
ANR4675E  
Server/subagent protocol violation - invalid (where the protocol breakdown  
occurred).  
Explanation: The SNMP subagent received an unexpected request from the server.  
System Action: The subagent will stop processing requests from the server  
sending the invalid requests.  
User Response: Contact your service representative.  
612  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4676E  
ANR4677I  
ANR4678I  
ANR4679W  
Unable to register another server.  
Explanation: The SNMP subagent received a request to register a new server and  
was unable to allocate the memory necessary to register the new server.  
System Action: The subagent will not register the new server.  
User Response: Contact your service representative.  
Session established with server name: The name of the registered server..  
Explanation: The SNMP subagent completed the registration of the identified  
server.  
System Action: The subagent will wait for additional requests from the server.  
User Response: None.  
Session closed with server name: The name of the deregistered server..  
Explanation: The SNMP subagent completed the deregistration of the identified  
server.  
System Action: None.  
User Response: None.  
Messages are no longer being forwarded to the SNMP subagent.  
Explanation: The server has encountered multiple errors in forwarding messages  
to the SNMP subagent. Messages are no longer being forwarded.  
System Action: The server continues operating, but messages are no longer being  
forwarded.  
User Response: Message forwarding can be re-initialized by either stopping the  
server and re-starting it. Message forwarding will also be re-started if the heartbeat  
function is in use and the server re-synchronizes with the subagent. This  
re-synchronization occurs if the subagent, dsmsnmp, is stopped for longer than a  
single heartbeat interval (the heartbeat interval is a server option and appears in the  
output of the QUERY OPT command) and then restarted.  
ANR4680I  
DPI subagent (The subagent name.): Connectedor reconnected, ready to  
receive requests.  
Explanation: The subagent has successfully connected or reconnected to the  
SNMP agent.  
System Action: The subagent is ready to receive requests from servers.  
Tivoli Storage Manager Messages  
613  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR4681W  
Connect to SNMP agent failed, will keep trying.  
Explanation: The subagent has failed in an attempt to connect to the SNMP agent.  
System Action: The subagent keeps retrying the connection.  
User Response: Make sure that the SNMP daemon is up, running and correctly  
configured.  
ANR4682W  
A SNMP agent connection error occurred. Attempting to re-establish  
connection.  
Explanation: An error has occurred in the communication between the subagent  
and the SNMP agent.  
System Action: The subagent will attempt to reconnect.  
User Response: Make sure that the SNMP daemon is up, running and correctly  
configured.  
ANR4683E  
Unable to open trace file ’file name’.  
Explanation: An error occurred while opening the file for writing trace data.  
System Action: The subagent continues operation without tracing.  
User Response: Ensure there is adequate space on the drive from which you are  
running the subagent and retry the program.  
ANR4684E  
Trap request failed - RC: Return code from the trap request. Server index: Server  
index number..  
Explanation: An error occurred while attempting to process a trap request from a  
server. data.  
System Action: The subagent processing continues.  
User Response: Make sure that the SNMP daemon is up, running and correctly  
configured.  
ANR4685E  
Insufficient memory for subagent initialization.  
Explanation: The SNMP subagent could not initialize due to the inability to  
obtain the required memory.  
System Action: Initialization of the subagent fails.  
User Response: Allocate additional memory to the subagent.  
614  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4686E  
Insufficient memory for subagent trace initialization.  
Explanation: The SNMP subagent trace could not initialize due to the inability to  
obtain the required memory.  
System Action: Initialization of the subagent fails.  
User Response: Allocate additional memory to the subagent.  
ANR4687E  
Server/subagent protocol violation - expecting registration request. Received  
request: The value of the request that was received.  
Explanation: The SNMP subagent was expecting a registration request. It actually  
received something other than a registration request.  
System Action: The subagent will stop processing requests from the server  
sending the invalid requests.  
User Response: Contact your service representative.  
ANR4688E  
Server/subagent protocol violation - incorrect request header version.  
Explanation: The SNMP subagent received a request from a server that was not at  
the same maintenance level as the subagent.  
System Action: The subagent will stop processing requests from the server  
sending the invalid requests.  
User Response: Ensure the server and subagent are at the same maintenance level.  
If they are, contact your service representative.  
ANR4689E  
Invalid request type received (The value of the request that was received.).  
Explanation: The SNMP subagent received an unexpected request from the server.  
System Action: The subagent will stop processing requests from the server  
sending the invalid requests.  
User Response: Contact your service representative.  
ANR4690E  
Unexpected request type (The value of the request that was received.) in trap data  
header.  
Explanation: The SNMP subagent received an invalid trap request from a server.  
System Action: The subagent will stop processing requests from the server  
sending the invalid requests.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
615  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4691I  
ANR4692I  
ANR4693I  
DPI subagent (The subagent name.): connected, ready to receive requests.  
Explanation: The subagent has successfully connected to the SNMP agent.  
System Action: The subagent is ready to receive request from servers.  
User Response: None.  
DPI subagent (The subagent name.): reconnected, ready to receive requests.  
Explanation: The subagent has successfully reconnected to the SNMP agent.  
System Action: The subagent is ready to receive request from servers.  
User Response: None.  
Interface Driver information will be loaded in quiet mode: Only warning and  
error messages will be displayed.  
Explanation: The server is loading information needed for the Administrative  
WEB Interface. To minimize message traffic, only error and warning messages will  
be displayed.  
System Action: When the command completes, WEB administrative information  
will be loaded into the server.  
User Response: None.  
ANR4694E  
SNMP Subagent Port Confirmation Has Failed.  
Explanation: The server was communicating configuration data to the SNMP  
subagent. An error occurred in the exchange. The server could not communicate  
interface information to the subagent.  
System Action: The server continues operation. The SNMP administrative  
interface is inoperative.  
User Response: The most likely cause of this problem is a temporary network  
failure. The server should be re-started to retry the connection to the SNMP  
subagent. If this problem occurs repeatedly, please contact you service  
representative.  
ANR4695E  
SNMP: Communications Failure in Receiving verb typeverb.  
Explanation: The SNMP client encountered a communications error in using the  
verb type verb to transfer information to or from the server and an SNMP client.  
System Action: The SNMP session ends and server operation continues.  
616  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: This may not be a problem if the SNMP subagent was terminated  
while the session was in progress. Otherwise, ensure that TCP/IP communications is  
running normally.  
ANR4697E  
SNMP: Failed to authenticate to server at address address, port port.  
Explanation: The SNMP client was attempting to run a session with the server at  
the indicated address and port number in response to an SNMP Get Request, which  
causes a Server Script to be run. The subagent connected to the indicated server, but  
failed in authentication.  
System Action: The SNMP subagent ends this attempt to run the script and  
continues operation.  
User Response: Ensure that the indicated server has an an administrative id of  
SNMPADMIN and that this adminstrative id has sufficient authority to run the script  
and commands it contains.  
ANR4698E  
ANR4699E  
ANR4700I  
SNMP: Communications Failure in Sending verb typeverb (command).  
Explanation: The SNMP client encountered a communications error in using the  
verb type verb to issue command command.  
System Action: The SNMP client session ends and subagent operation continues.  
User Response: Contact your service representative.  
SNMP: Receive Buffer overflow.  
Explanation: The SNMP client encountered an overflow error in transferring  
information to or from the server.  
System Action: The SNMP client session ends and subagent operation continues.  
User Response: Contact your service representative.  
The server move batch size has been set to new batch size. Move operations that  
start after this point will use the new value.  
Explanation: A SETOPT commmand was used to set the value for the move batch  
size value. This setting determines the maximum number of files that are moved on  
the server in one database transaction, dependent also on the setting for the move  
size thrshold. The setting influences file movement for server migration, reclmation,  
storage pool backup, and move data operations.  
System Action: The server uses this new setting for move operations that are  
started after this message is issued.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
617  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4701I  
The server move size threshold has been set to new threshold. Move operations  
that start after this point will use the new value.  
Explanation: A SETOPT commmand was used to set the value for the move size  
threshold value. This setting determines the maximum number of megabytes that are  
moved on the server in one database transaction, dependent also on the setting for  
the move batch size. The setting influences file movement for server migration,  
reclmation, storage pool backup, and move data operations.  
System Action: The server uses this new setting for move operations that are  
started after this message is issued.  
User Response: Contact your service representative.  
ANR4702I  
The server transaction group maximum has been set to new value. Client  
sessions that are started after this point will use the new value.  
Explanation: A SETOPT commmand was used to set the value for the  
maxmimum number of files that can be sent from the client in a single database  
transaction.  
System Action: The server uses this new setting for client sessions that are started  
after this message is issued.  
User Response: Contact your service representative.  
ANR4703E  
Invalid key ring filename Key Ring Filename  
Explanation: The key ring filename specified did not contain the .kyr extention.  
System Action: None.  
User Response: Rename your key ring filename to contain the .kyr extention.  
Reexcute the command with the new filename.  
ANR4704I  
Key ring filename and password have been set. Restart the server to use the  
new settings  
Explanation: The key ring filename have been set to the new value specified in  
the DEFINE KEYRING command.  
System Action: None.  
User Response: Restart the server to use the new key ring information.  
618  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4705I  
The server IDL definitions have not been installed. These definitions will need  
to be installed for the Web Administrator interface to work.  
Explanation: The server attempted to query the server IDL interface and found no  
definitions defined. Because of this error the HTTP engine returns a 404 not found  
message.  
System Action: None.  
User Response: If you would like to use the server web administrator interface  
you will need to:  
1. Halt the server.  
2. Issue the command DSMSERV RUNFILE dsmserv.idl. For AS/400 command  
see next step.  
3. For AS/400, issue the command STRSVRADSM SVRMODE(*PRPWEB).  
4. Restart the server.  
ANR4706W  
Unable to open file Filename to satisfy web session Session ID.  
Explanation: A web browser requested a file and the server could not find the file  
on the local file system. Special note, some files requested from the server are not  
vaild and are caused by a browser error. For example, a request for  
CommandLineBeanInfo.class is not a valid file request. However, a request of a GIF  
image or HTML page should not produce this error.  
System Action: None.  
User Response: Verify that permission for the file are set correctly and file exists.  
ANR4707E  
Import/Loaddb command operation terminated - incomplete input volume list.  
Explanation: The list of volumes needed to process the command was incomplete.  
At least one volume needed for the operation is missing from the end of the list.  
System Action: The command operation is ended.  
User Response: Issue the command again and make sure the necessary volumes  
are included in the volume list.  
ANR4708I  
Native SSL support has been disabled, please use the web proxy.  
Explanation: Starting in this version of this product native Secure Socket Layer  
support has been removed. This feature has been replace with the web proxy.  
Support for non-secure http request (COMMMETHOD HTTP) has not been  
disabled.  
System Action: None.  
Tivoli Storage Manager Messages  
619  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response:  
1. Remove COMMMETHOD HTTPS from your option file.  
2. Install and configure the web proxy. See Quick Start Appendices for more  
information on how to install and configure the web proxy.  
ANR4709W  
Intervention required to mount volume Volume Name on Library Manager  
Server Server Name.  
Explanation: A volume mount is awaiting operator intervention on the specified  
library manager server.  
System Action: The volume mount operation waits for operator intervention.  
User Response: Refer to the server consol and/ir activity log on the named library  
manaer server to determine the action that needs to be performed to complete the  
mount operation.  
ANR4710W  
Library manager Server Name could not be contacted to control library Library  
Name.  
Explanation: The specified library manager server could not be contacted for  
control of the named library.  
System Action: The server will continue to contact the named library manager  
server. Volume mounts in the library will fail until communication is successful.  
User Response: Determine why the named server is not running or why the  
network prevents communication with te named server.  
ANR4712E  
Command: The DEVCLASS parameter is only valid for volume history types  
DBBACKUP or DBSNAPSHOT.  
Explanation: The command failed because an invalid volume history type was  
specified for the TYPE= parameter.  
System Action: The command fails, and server operation continues.  
User Response: Re-issue the command and specify a valid type value.  
ANR4980I  
Auditing Interface Driver definitions.  
Explanation: The server is beginning an audit of the definitions for Web interface.  
System Action: The server will audit all definitions for the Web interface and  
report any problems.  
User Response: None.  
620  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4981E  
Interface Driver audit completed - Inconsistencies were found.  
Explanation: The server found errors during the audit of the definitions for Web  
interface.  
System Action: The Web Interface is not correctly installed. The Web Admin will  
not work correctly, but the server may be run without any problems.  
User Response: Insure you are using the correct IDL file for the server level you  
are running. Examine error messages that may have been displayed before and/or  
after this message and correct any problems, if possible. If the cause of this can not  
be determined or resolved, contact your support representative.  
ANR4982I  
Interface Driver audit completed - definitions are consistent.  
Explanation: The server successfully completed the installation of the definitions  
for the Web interface.  
System Action: The Web Interface is now installed. The server may be run  
without any problems.  
User Response: None.  
ANR4983I  
Auditing Interface Driver Groups.  
Explanation: The server is auditing the driver groups.  
System Action: The server will audit the driver groups and proceed to the next  
step.  
User Response: None.  
ANR4984E  
Error description  
Explanation: The server found errors during the audit of the definitions for Web  
interface.  
System Action: The audit will fail.  
User Response: Insure you are using the correct IDL file for the server level you  
are running. Examine error messages that may have been displayed before this  
message and correct any problems, if possible. If the cause of this can not be  
determined or resolved, contact your support representative. If you contact your  
support representative, the entire text of this message should be reported.  
ANR4985I  
Auditing Interface Driver Group Members.  
Explanation: The server is auditing the driver group members.  
Tivoli Storage Manager Messages  
621  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server will audit the driver group members and proceed to the  
next step.  
User Response: None.  
ANR4986I  
ANR4987E  
ANR4988I  
ANR4989I  
ANR4990I  
Auditing Interface Driver Classes.  
Explanation: The server is auditing the driver classes.  
System Action: The server will audit the driver classes and proceed to the next  
step.  
User Response: None.  
Audit processing failed: sufficient memory is not available for processing.  
Explanation: At RUNFILE time, the server is unable to process the IDL data due  
to insufficient memory.  
System Action: Server runfile stops.  
User Response: Restart the server runfile process with more memory available.  
Auditing Interface Driver Complex Class containers.  
Explanation: The server is auditing the driver class containers.  
System Action: The server will audit the driver class containers and proceed to the  
next step.  
User Response: None.  
Auditing Interface Driver Operations.  
Explanation: The server is auditing the driver operations.  
System Action: The server will audit the driver operations and proceed to the next  
step.  
User Response: None.  
Auditing Interface Driver Operation Parameters.  
Explanation: The server is auditing the driver operation parameters.  
System Action: The server will audit the driver operation parameters and proceed  
to the next step.  
User Response: None.  
622  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR4991I  
ANR4992I  
Auditing Interface Driver Tasks.  
Explanation: The server is auditing the driver tasks.  
System Action: The server will audit the driver tasks and proceed to the next step.  
User Response: None.  
Auditing Interface Driver Task Members.  
Explanation: The server is auditing the driver task members.  
System Action: The server will audit the driver task members and proceed to the  
next step.  
User Response: None.  
ANR5000E (S/390)  
Unable to load tape deletion exit.  
Explanation: The tape deletion exit module specified in the options file cannot be  
loaded.  
System Action: Server operation continues.  
User Response: Ensure that the tape deletion exit module is in the system linklist  
or in the JOBLIB/STEPLIB for the server.  
ANR5010E (S/390)  
Unable to initialize disk driver - internal error code from IUCV.  
Explanation: The server’s disk driver cannot be initialized because the error code  
has been received from the IUCV DECLARE BUFFER function.  
System Action: Server initialization fails.  
User Response: For a description of the reported error code, refer to the IUCV  
documentation in the CP Programming Services publication for your specific  
operating system.  
ANR5011E (S/390)  
Unable to open disk vaddr - invalid virtual device address.  
Explanation: A disk cannot be opened for processing because the specified virtual  
address is beyond the supported range. Virtual addresses must be specified in the  
range 0001 to FFFF.  
System Action: Server operation continues.  
User Response: Specify a valid virtual address.  
Tivoli Storage Manager Messages  
623  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5012E (S/390)  
Unable to open disk vaddr - error code received from FILEDEF.  
Explanation: A disk cannot be opened for processing because the error code has  
been received from the FILEDEF command. The server enters one FILEDEF  
command per open disk so that the CMS DISKID function may be used.  
System Action: Server operation continues.  
User Response: For a description of the FILEDEF error code, refer to the CMS  
Command Reference publication for your operating system.  
ANR5013E (S/390)  
ANR5014E (S/390)  
ANR5015E (S/390)  
Unable to open disk vaddr - virtual disk not attached.  
Explanation: A disk cannot be opened because the virtual disk is not attached to  
the server’s virtual machine.  
System Action: Server operation continues.  
User Response: Ensure that the VM DASD volume containing the disk is online,  
and that the disk is properly linked to the server’s virtual machine.  
Unable to open disk vaddr - error code received from DISKID.  
Explanation: A disk cannot be opened for processing because the error code has  
been received from the DISKID function.  
System Action: Server operation continues.  
User Response: For a description of the DISKID error code, refer to the CMS  
Command Reference publication for your operating system.  
Unable to open disk vaddr - internal error code connecting to Block I/O System  
Service.  
Explanation: A disk cannot be opened for processing because the IUCV  
CONNECT error code is received when attempting to connect to the CP DASD  
Block I/O System Service.  
System Action: Server operation continues.  
User Response: For a description of the IUCV CONNECT error code, refer to the  
IUCV documentation in the CP Programming Services publication for your specific  
operating system.  
624  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5016E (S/390)  
Unable to open disk vaddr - device type not supported.  
Explanation: A disk cannot be opened for processing because its device type is  
not supported.  
System Action: Server operation continues.  
User Response: Use only the disk devices supported by the CP DASD Block I/O  
System Service.  
ANR5017E (S/390)  
Unable to open disk vaddr - block size not supported.  
Explanation: A disk cannot be opened for processing because its formatted block  
size is not supported.  
System Action: Server operation continues.  
User Response: Use only the disks formatted with block sizes supported by the  
CP DASD Block I/O System Service.  
ANR5018E (S/390)  
Unable to open disk vaddr - IUCV path already exists to device.  
Explanation: A disk cannot be opened because a path already exists for this  
device to the CP DASD Block I/O System Service.  
System Action: Server operation continues.  
User Response: Contact your service representative.  
ANR5019E (S/390)  
Unable to open disk vaddr - internal error code from Block I/O System Service.  
Explanation: A disk cannot be opened for processing because the connection to  
the CP DASD Block I/O System Service has been severed with error code.  
System Action: Server operation continues.  
User Response: For a description of the severed error code, refer to the  
documentation for the CP DASD Block I/O System Service in the CP Programming  
Services publication for your specific operating system.  
ANR5020E (S/390)  
Unable to open disk vaddr - device is read-only.  
Explanation: A disk cannot be opened for processing because it is accessible only  
as a read-only device. All server disks must be accessible in read/write mode.  
Tivoli Storage Manager Messages  
625  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: Ensure that the disk is properly linked in read/write mode.  
ANR5021E (S/390)  
Unable to perform I/O to disk vaddr - internal error code on IUCV send.  
Explanation: The IUCV SEND error code is received when the server attempts to  
perform I/O to a disk.  
System Action: Server operation continues.  
User Response: For a description of the IUCV SEND error code, refer to the  
IUCV documentation in the CP Programming Services publication for your specific  
operating system.  
ANR5022E (S/390)  
Unable to perform I/O to disk vaddr - permanent error writing to block block.  
Explanation: The server encounters a permanent error while writing to the  
specified disk and block.  
System Action: Server operation continues.  
User Response: Reformat or replace the disk.  
ANR5023E (S/390)  
Unable to perform I/O to disk vaddr - permanent error reading from block  
block.  
Explanation: The server encounters a permanent error while reading from the  
specified disk and block.  
System Action: Server operation continues.  
User Response: Reformat or replace the disk.  
ANR5024E (S/390)  
Unable to perform I/O to disk vaddr - format error detected.  
Explanation: The server encounters a format error on the specified disk.  
System Action: Server operation continues.  
User Response: Reformat the disk by using the DSMDISK exec.  
626  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5025E (S/390)  
Disk vaddr has been reset and is no longer available.  
Explanation: A disk is reset during operation because a CP RESET or DETACH  
command has been entered from the server’s console.  
System Action: The disk is marked off-line.  
User Response: Ensure that the disk is properly reattached to the server’s virtual  
machine.  
ANR5026E (S/390)  
Open of data set dsn failed, return code rc, reason code reason.  
Explanation: Data set dsn cannot be opened.  
System Action: Server operation continues.  
User Response: Verify that dsn is a VSAM linear data set. If dsn is a valid VSAM  
linear data set, contact your service representative.  
ANR5027E (S/390)  
Open of DDNAME ddname failed, insufficient memory.  
Explanation: The server is unable to open ddname ddname due to a lack of  
storage.  
System Action: Server operation continues.  
User Response: Increase the region for the server or lower the MAXSESSIONS  
parameter in the server options file. There are three ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
2. On MVS, increase the size of the REGION parameter on the JOB or EXEC  
statement of the JCL used to start the server.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
Tivoli Storage Manager Messages  
627  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5028E (S/390)  
Open of data set dsn failed; zero pages in data set.  
Explanation: The VSAM linear data set dsn has no space. This message appears  
when:  
you issue def vol|dbvol|logvol for a volume that has not been formatted using  
the dsmfmt utility  
you run the dsmfmt utility against a data set that is too small  
an existing data set has been corrupted  
System Action: Server operation continues.  
User Response: Run the dsmfmt utility, or reallocate the VSAM linear data set as  
appropriate.  
ANR5030E (S/390)  
Dynamic allocation of data set dsn failed, return code rc, error code error-code,  
info code info-code.  
Explanation: The dynamic allocation of data set dsn fails. The return code rc,  
error code error-code and information code info-code, are in decimal and can be  
found in the Dynamic Allocation section of MVS/ESA Programming: Authorized  
Assembler Services Guide.  
System Action: Server operation continues.  
User Response: Ensure that the data set dsn is available for allocation by the  
server.  
ANR5032E (S/390)  
Unable to free DDNAME dsn, return code rc, error code error-code, info code  
info-code.  
Explanation: The dynamic deallocation of data set dsn fails. The return code rc,  
error code error-code and information code info-code are in decimal and can be  
found in the Dynamic Allocation section of MVS/ESA Programming: Authorized  
Assembler Services Guide.  
System Action: Server operation continues.  
User Response: Contact your service representative.  
ANR5033E (S/390)  
Close of ddname dsn failed, return code rc, reason code reason.  
Explanation: Data set dsn cannot be closed.  
System Action: Server operation continues.  
628  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Verify that dsn is a VSAM linear data set. If dsn is a valid VSAM  
linear data set, contact your service representative.  
ANR5034E (S/390)  
Unable to allocate processor for ddname dsn.  
Explanation: The number of simultaneous tapes supported by the server has been  
exceeded.  
System Action: Server operation continues.  
User Response: Contact your service representative for a fix that allows additional  
tapes.  
ANR5035E (S/390)  
Dynamic allocation of tape unit unit failed, return code rc, error code  
error-code, info code info-code.  
Explanation: The dynamic allocation of a tape unit unit fails. The return code rc,  
error code error-code, and information code info-code are in decimal and can be  
found in the Dynamic Allocation section of MVS/ESA Programming: Authorized  
Assembler Services Guide.  
System Action: Server operation continues.  
User Response: Examine the MVS messages preceding this message. They should  
explain the cause of the allocation problem; otherwise, contact your service  
representative.  
ANR5036E (S/390)  
Open of tape unit unit (ddname ddname) failed, return code rc.  
Explanation: Open of ddname ddname fails.  
System Action: Server operation continues.  
User Response: Examine the MVS messages preceding this message. The  
ANR1401W message and the volume name will explain the problem. If necessary,  
contact your service representative.  
ANR5037E (S/390)  
Unable to acquire processor, dsn.  
Explanation: The number of simultaneous tapes supported by the server has been  
exceeded.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
629  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your service representative for a fix that allows additional  
tapes.  
ANR5039E (S/390)  
Unable to open disk vaddr - IUCV MAXCONN value exceeded.  
Explanation: The disk at virtual address vaddr cannot be opened due to a lack of  
IUCV connections.  
System Action: Server operation continues.  
User Response: Increase the IUCV MAXCONN value in the server CP directory  
entry and restart the server.  
ANR5040E (S/390)  
Data set name dsn contains qualifier qual that is longer than 8 characters.  
Explanation: Data set dsn qualifier qual is too long. Data set qualifiers must be 1  
to 8 characters long.  
System Action: Server operation continues.  
User Response: Specify data set name qualifiers with a maximum of 8 characters.  
ANR5041E (S/390)  
Data set name dsn contains a null qualifier.  
Explanation: Data set dsn contains null qualifier (either 2 consecutive periods or  
an ending period without a subsequent qualifier). Data set qualifiers must be 1 to 8  
characters long.  
System Action: Server operation continues.  
User Response: Specify valid data set name qualifiers.  
ANR5042E (S/390)  
Data set name dsn contains qualifier qual that does not begin, with an alpha  
character.  
Explanation: Data set dsn qualifier qual does not begin with an alpha character.  
Data set qualifiers must start with an alpha character.  
System Action: Server operation continues.  
User Response: Specify data set name qualifiers that begin with an alpha  
character.  
630  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5043E (S/390)  
Data set name dsn contains qualifier qual that contains a character that is not  
alphanumeric.  
Explanation: Data set dsn qualifier qual contains a character that is not  
alphanumeric. Data set qualifiers must contain only alphanumeric characters.  
System Action: Server operation continues.  
User Response: Specify data set name qualifiers that contain only alphanumeric  
characters.  
ANR5044E (S/390)  
Cannot format data set dsn. Data set is not empty.  
Explanation: The server will not format dsn because it is not empty.  
System Action: Server operation continues.  
User Response: Verify that dsn is the correct data set you’d like to format. The  
server formats empty data sets only.  
ANR5045E (S/390)  
Failed to open dataset dsn. Error detected with the VSAM high-used (VSAM  
high-used value) or high-allocated (VSAM high-allocated value) values.  
Explanation: The server did not open dataset dsn. The VSAM high-used and  
high-allocated attributes are outside of the range expected by the server. The values  
may have been corrupted by moving the dataset using anything other than a logical  
move.  
System Action: Volume is marked read-only, or not brought on-line. Server  
operation continues.  
User Response: Issue listcat entry(dsn) all to check the high-used and  
high-allocated values. If you moved the dataset, verify that a logical move was  
performed. Correct any user errors. Otherwise, contact your service representative.  
ANR5046I (S/390)  
Dynamic allocation of tape unit unit was cancelled by the operator.  
Explanation: The dynamic allocation of a tape unit unit was cancelled by the  
operator.  
System Action: Server operation continues, tape mount fails.  
User Response: None.  
Tivoli Storage Manager Messages  
631  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5048E (S/390)  
Tape dataset allocation of block size changed from server value to current value.  
Explanation: The server allocated the block size of its tape data set as server  
value, but it has been changed to current value.  
System Action: Current tape operation fails.  
User Response: Check for MVS or system application messages preceding this  
message that indicate what caused the change to the block size. Check for any  
system exits that may change the block size (for example, IEFDB401). Ensure that  
the server can use its original value for the block size.  
ANR5049E (S/390)  
Tape data set allocation of data set organization changed from hex server value  
to hex current value.  
Explanation: The server allocated the data set organization of its tape data set as  
server value, but it has been changed to current value in the data control block  
(DCB).  
System Action: Current tape operation fails.  
User Response: Check for MVS or system application messages preceding this  
message that indicate what caused the change to the data set organization. Check for  
any system exits that may change the data set organization (for example,  
IEFDB401). Ensure that the server can use its original value for the data set  
organization. See MVS/DFP V3R3 Macro Instructions for Data Sets for valid values.  
ANR5050E (S/390)  
Tape data set allocation of record format changed from hex server value to hex  
current value.  
Explanation: The server allocated the record format of its tape data set as server  
value, but it has been changed to current value in the data control block (DCB).  
System Action: Current tape operation fails.  
User Response: Check for MVS or system application messages preceding this  
message that indicate what caused the change to the record format. Check for any  
system exits that may change the record format (for example, IEFDB401). Ensure  
that the server can use its original value for the record format. See MVS/DFP V3R3  
Macro Instructions for Data Sets for valid values.  
632  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5051E (S/390)  
Tape data set allocation of logical record length changed from server value to  
current value.  
Explanation: The server allocated the logical record length of its tape data set as  
server value, but it has been changed to current value.  
System Action: Current tape operation fails.  
User Response: Check for MVS or system application messages preceding this  
message that indicate what caused the change to the logical record length. Check for  
any system exits that may change the logical record length (for example,  
IEFDB401). Ensure that the server can use its original value for the logical record  
length.  
ANR5060E (S/390)  
Unable to open VTAM ACB Name name, rc code.  
Explanation: The server cannot be identified to VTAM with the ACB name  
specified.  
System Action: Server operation continues. Support for the 3270 and SNALU6.2  
COMMmethods is disabled. The server periodically tries to open the ACB and when  
successful, the 3270 and SNALU6.2 COMMmethods are enabled.  
User Response: For a description of the reported error code, refer to VTAM  
Programming. If the ACB has been temporarily varied off, no action is required.  
The server periodically tries to open the ACB. If the ACB is not defined and the  
COMMmethods 3270 or SNALU6.2 are not supported for any clients, shut down  
the server with the HALT command and set the LUNAME statement in the server  
options file to *NONE*. If COMMmethods 3270 or SNALU6.2 are supported,  
contact your VTAM (network) administrator to ensure that the ACB name has been  
properly defined in a member of SYS1.VTAMLST.  
ANR5061E (S/390)  
Unable to issue SETLOGON for VTAM ACB Name name, rc code, reas reason,  
rpl: rtncd return code fdb2 feedback.  
Explanation: The server detects an error while informing VTAM that it is ready to  
accept a session.  
System Action: Server operation continues. Support for the 3270 and SNALU6.2  
COMMmethods is disabled. The server periodically tries to reissue the SETLOGON  
instruction.  
User Response: For a description of the reported error code, refer to VTAM  
Programming.  
Tivoli Storage Manager Messages  
633  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5062E (S/390)  
Unable to allocate number of bytes bytes for VTAM control blocks.  
Explanation: The server is unable to access the storage it needs to support the  
COMMmethods 3270 and SNALU6.2.  
System Action: The COMMmethods 3270 and SNALU6.2 are disabled. If the  
storage for the global control block cannot be accessed, these COMMmethods  
remain disabled until the server is shut down with the HALT command and  
restarted. Otherwise, the server periodically tries to access the needed storage and  
when successful, the 3270 and SNALU6.2 COMMmethods are enabled. Server  
operation continues.  
User Response: If the support for the COMMmethods 3270 and SNALU6.2 is  
needed immediately, shut down the server (with the HALT command), resolve the  
storage problem, and restart the server. If the COMMmethods 3270 and SNALU6.2  
are not used, shut down the server, set the LUNAME to *NONE*, and restart the  
server.  
ANR5063E (S/390)  
Unable to allocate session number for LU LU ID.  
Explanation: The server is unable to assign a session number to the incoming  
session.  
System Action: Server operation continues. The server rejects the incoming  
session.  
User Response: If the MAXSESSIONS statement in the server options file has  
been set correctly, the end-user (client) must wait until there is a free session before  
retrying to connect with the server. If the MAXSESSIONS statement is in error,  
shut down the server, correct the MAXSESSIONS statement, restart the server, and  
have the client retry connecting with the server.  
ANR5064E (S/390)  
Unable to allocate number of bytes bytes for VTAM session with LU LU ID.  
Explanation: The server is unable to access the storage needed to support the  
incoming 3270 dial-in session.  
System Action: Server operation continues. The incoming session is rejected.  
User Response: Allocate additional storage to the server virtual machine. There  
are four ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
634  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. On MVS, increase the size of the REGION parameter on the JOB or EXEC  
statement of the JCL used to start the server.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) to allow  
changes made to the server options file to take place.  
ANR5065E (S/390)  
Unable to open session with LU LU ID CID conversation ID, rc code reason  
reason, rpl: rtncd return code fdb2 feedback.  
Explanation: The server encounters an error while accepting an incoming session  
by way of a VTAM OPNDST instruction. The session is rejected.  
System Action: Server operation continues.  
User Response: For a description of error code, refer to VTAM Programming.  
ANR5066E (S/390)  
Unable to close session with LU LU ID CID conversation ID, rc code reason  
reason, rpl: rtncd return code fdb2 feedback.  
Explanation: The server encounters an error while ending a session.  
System Action: Server operation continues.  
User Response: For a description of the error code, refer to VTAM Programming.  
ANR5067E (S/390)  
Unable to close VTAM ACB Name name, rc code.  
Explanation: The server detects an error while closing the ACB for the specified  
name.  
System Action: The server proceeds with HALT command processing.  
User Response: For a description of the reported error code, refer to VTAM  
Programming.  
Tivoli Storage Manager Messages  
635  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5068E (S/390)  
ANR5069E (S/390)  
ANR5070I (S/390)  
Unable to receive on session with LU LU ID CID conversation ID, rc code  
reason reason, rpl: rtncd return code fdb2 feedback sense sense code.  
Explanation: The server encounters an error while receiving data on the session.  
System Action: Server operation continues, and the session is ended.  
User Response: For a description of the reported error code, refer to VTAM  
Programming.  
Unable to send on session with LU LU ID CID conversation ID, rc code reason  
reason, rpl: rtncd return code fdb2 feedback sense sense code.  
Explanation: The server encounters an error while sending data on the session.  
System Action: Server operation continues, and the session is ended.  
User Response: For a description of the reported error code, refer to VTAM  
Programming.  
3270 Dial-in driver terminated as requested.  
Explanation: The server’s 3270 dial-in communications driver is ending as  
requested.  
System Action: Server operation continues with support for the 3270  
COMMmethod disabled.  
User Response: None.  
ANR5071W (S/390)  
Application resource name was defined to VTAM with APPC=NO.  
Explanation: The specified VTAM application has been defined with APPC=NO.  
This definition, may be normal for your installation if SNALU6.2 is not used by the  
clients. If this is true, then this message can be ignored.  
System Action: Server operation continues. Support for the SNALU6.2 is disabled.  
User Response: If clients are using SNALU6.2, define the VTAM application with  
APPC=YES. For the server to recognize the new definition, you must stop the  
server by using the HALT command and restart the server.  
636  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5080I (S/390)  
IUCV driver ready for connection with clients.  
Explanation: The server’s IUCV communications driver is ready to receive  
connection requests from clients.  
System Action: Server operation continues. The IUCV is enabled.  
User Response: None.  
ANR5081E (S/390)  
Unable to initialize IUCV driver - code code.  
Explanation: The server’s IUCV communications driver cannot initialize itself  
because it received the error code code when entering the IUCV DECLARE  
BUFFER function.  
System Action: Server initialization fails.  
User Response: For a description of the reported error code, refer to the IUCV  
documentation in the CP Programming Services publication for your specific  
operating system, and the TCP/IP for MVS Programmers Reference for your  
version of TCP/IP.  
ANR5082W (S/390)  
IUCV connection terminated - insufficient memory.  
Explanation: An IUCV connection request is refused by the server’s IUCV  
communications driver because sufficient memory is not available to construct a  
session.  
System Action: Server operation continues.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
2. On MVS, increase the size of the REGION parameter on the JOB or EXEC  
statement of the JCL used to start the server.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64 KB of memory  
to be allocated.  
Tivoli Storage Manager Messages  
637  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
ANR5083E (S/390)  
IUCV connection terminated - error code accepting connect request.  
Explanation: The server’s IUCV communications driver is unable to accept a new  
connection from a client because error code has been received from the IUCV  
ACCEPT function.  
System Action: Server operation continues.  
User Response: For a description of the IUCV ACCEPT error code, refer to the  
IUCV documentation in the CP Programming Services publication for your specific  
operating system, and the TCP/IP for MVS Programmers Reference for your  
version of TCP/IP.  
ANR5084W (S/390)  
IUCV connection terminated - server HALT in progress.  
Explanation: The server’s IUCV communications driver refuses a request for a  
client connection because the HALT command has been entered.  
System Action: The server rejects the session and proceeds with HALT command  
processing.  
User Response: None.  
ANR5085I (S/390)  
IUCV driver unable to start. Server terminating.  
Explanation: The server is unable to start the thread to monitor the status of the  
IUCV communications driver.  
System Action: The server shuts down.  
User Response: If sufficient storage is available when this error occurs, contact  
your service representative. On MVS, ensure the region size parameter on the JCL  
is at least 128MB. Otherwise if on VM, ensure that the server virtual machine is at  
least 128MB in size.  
638  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5086I (S/390)  
IUCV driver terminated.  
Explanation: The IUCV communications driver has shut down.  
System Action: Server operation continues. Support for the IUCV COMMmethod  
is disabled. The server periodically tries to restart the IUCV communications driver.  
User Response: None.  
ANR5087I (S/390)  
IUCV driver starting.  
Explanation: The server is reporting that it is in the process of starting the IUCV  
communications driver.  
System Action: The server attempts to initiate a process that will monitor the  
status of the IUCV communications driver.  
User Response: None.  
ANR5088E (S/390)  
Unable to establish a wrap connection - return code code.  
Explanation: The server is unable to establish an IUCV connection with itself.  
System Action: Server operation continues. Support for the IUCV COMMmethod  
is disabled. The server will periodically retry the connect.  
User Response: For a description of this IUCV CONNECT error code, refer to the  
IUCV documentation in the CP Programming Services publication for your specific  
operating system, and the TCP/IP for MVS Programmers Reference for your  
version of TCP/IP.  
ANR5089I (S/390)  
IUCV driver terminated as requested.  
Explanation: The server’s IUCV communications driver is ending as requested.  
System Action: Server operation continues with support for the ADMIUCV  
COMMmethod disabled.  
User Response: None.  
ANR5090I (S/390)  
TCP/IP driver ready for connection with clients on port port number.  
Explanation: The server’s TCP/IP communications driver is ready to receive  
connection requests from clients.  
Tivoli Storage Manager Messages  
639  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. Support for the TCP/IP COMMmethod  
is enabled.  
User Response: None.  
ANR5091E (S/390)  
Unable to initialize TCP/IP driver - insufficient memory.  
Explanation: The server’s TCP/IP communications driver is unable to initialize  
itself due to insufficient memory (virtual storage).  
System Action: Server initialization fails.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
2. On MVS, increase the size of the REGION parameter on the EXEC or JOB  
statement of the JCL used to start the server.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
ANR5092E (S/390)  
Unable to initialize TCP/IP driver - error creating acceptor socket.  
Explanation: The server’s TCP/IP communications driver is unable to create its  
critical listening socket, and so TCP/IP communications cannot be initialized.  
System Action: Server initialization continues. TCP/IP communications  
initialization will be retried.  
User Response: Check that TCP/IP is running, and that TCPName in the options  
file matches the TCP/IP subsystem name you intend to use.  
640  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5093E (S/390)  
Unable to establish TCP connection - accept error.  
Explanation: The server’s TCP/IP communications driver detects an internal error  
while attempting to accept a new client connection.  
System Action: Server operation continues.  
User Response: Report the error to your service representative.  
ANR5094W (S/390)  
Unable to establish TCP connection - insufficient memory.  
Explanation: A TCP/IP connection request has been refused by the server’s  
TCP/IP communications driver because sufficient memory is not available to  
construct a session.  
System Action: Server operation continues.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
2. On MVS, increase the size of the REGION parameter on the EXEC or JOB  
statement of the JCL used to start the server.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
ANR5095W (S/390)  
Unable to establish TCP connection - server HALT in progress.  
Explanation: The server’s TCP/IP communications driver refuses a request for a  
client connection because the HALT command has been entered.  
System Action: The server rejects the session and proceeds with HALT command  
processing.  
User Response: None.  
Tivoli Storage Manager Messages  
641  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5096W (S/390)  
Unable to initialize OE BPX TCP/IP driver - TCP/IP is down level.  
Explanation: Although the OS/390 is at V2R5 or above the level of TCP/IP is  
below V3R4 level, and so OE BPX TCP/IP communications cannot be initialized.  
System Action: Server initialization continues. TCP/IP communications is  
initialized, instead of OE BPX TCP/IP.  
User Response: Make sure the TCP/IP V3R4 or above is installed and running in  
the system if OE BPX TCP/IP communication is to be used.  
ANR5097I (S/390)  
TCP/IP driver terminated as requested.  
Explanation: The server’s TCP/IP communications driver is ending as requested.  
System Action: Server operation continues with support for the TCP/IP  
COMMmethod disabled.  
User Response: None.  
ANR5098I (S/390)  
TCP/IP driver starting.  
Explanation: The server is in the process of starting the TCP/IP communications  
driver.  
System Action: The server tries to initiate a thread that will monitor the status of  
the TCP/IP communications driver.  
User Response: None.  
ANR5099E (S/390)  
Unable to initialize TCP/IP driver - error binding acceptor socket socket number  
(rc = code).  
Explanation: The server’s TCP/IP communications driver detects an internal error  
while attempting to bind the acceptor socket.  
System Action: The server ends the TCP/IP acceptor process. Server operation  
continues without support for the TCP/IP COMMmethod. The server tries to restart  
the acceptor process periodically.  
User Response: Report the error to your service representative.  
642  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5100E (S/390)  
Unable to initialize TCP/IP driver -error listening on acceptor socket socket  
number (rc = code).  
Explanation: The server’s TCP/IP communications driver detects an internal error  
while attempting to listen for a connection on the acceptor socket.  
System Action: The server ends the TCP/IP acceptor process. Server operation  
continues without support for the TCP/IP COMMmethod. The server periodically  
tries to restart the acceptor process.  
User Response: Report the error to your service representative.  
ANR5101W (S/390)  
TCP/IP communications driver terminating.  
Explanation: The server’s TCP/IP communications driver has shut down.  
System Action: Server operation continues without support for the TCP/IP  
COMMmethod option. The server periodically tries to restart the TCP/IP  
communications driver if the server is not in the process of shutting down.  
User Response: If the server is not in the process of shutting down, this message  
may indicate that the TCP/IP server is not available or that a server internal error  
has occurred. Review the console log to determine if an internal error has occurred.  
If an internal error has occurred, contact your service representative. If the TCP/IP  
server is unavailable, correct the problem and the server will automatically reinitiate  
the TCP/IP communications driver.  
ANR5102W (S/390)  
Error received for connection connection number (socket socket number). TCP/IP  
driver will stop, then re-start.  
Explanation: The server’s TCP/IP communications driver received an error for the  
specified connection.  
System Action: The server stops the TCP/IP communications driver, and restarts  
the communications driver.  
User Response: This process may take up to 5 minutes. If the condition persists,  
report the problem to your service representative.  
ANR5103I (S/390)  
CLIO/S (IBM)TCP/IP driver ready for service on port clio port number.  
Explanation: The server’s CLIO/S TCP/IP communications driver is ready to  
handle connection requests to and from AIX clients using COMMmethod CLIO  
through an IBM TCP/IP host network.  
Tivoli Storage Manager Messages  
643  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. Support for the TCPName and  
CLIOPort server options is enabled.  
User Response: None.  
ANR5104E (S/390)  
Unable to initialize CLIO/S (IBM)TCP/IP driver - error creating listening  
socket.  
Explanation: The server’s CLIO/S communication driver is unable to create its  
critical listening socket; therefore, CLIO/S (IBM)TCP/IP communication cannot be  
initialized.  
System Action: Server initialization continues. CLIO/S (IBM)TCP/IP  
communication initialization will be retried every minute. This message will be  
suppressed after being issued for the third time; however, attempts to initialize  
CLIO/S communications will continue every minute until message ANR5103I is  
issued indicating CLIO/S driver is ready for service.  
User Response: Check that TCP/IP is running, and that TCPName, in the options  
file, matches the name of the target TCP/IP address space.  
ANR5105I (S/390)  
Interlink TCPaccess driver is ready for service on port interlink port number.  
Explanation: The server’s Interlink TCPaccess communications driver is ready to  
receive connection requests from clients connected through Interlink TCPaccess.  
System Action: Server operation continues. Support for the ICSSname and  
ICSPort server options is enabled.  
User Response: None.  
ANR5106E (S/390)  
Unable to initialize Interlink TCPaccess driver - error opening listen endpoint.  
Explanation: The server’s Interlink TCPaccess driver is unable to create its critical  
listen endpoint; Interlink TCPaccess communication cannot be initialized.  
System Action: Server initialization continues. Interlink TCPaccess  
communications will be retried every minute and this message will suppressed after  
being issued three times.  
User Response: Check that TCPaccess is running and that ICSSname, in the  
options file, matches the TCPaccess subsystem name you intend to use. The  
ICSSname option should match the SSN parameter of the PROC statement in the  
TCPaccess startup procedure. Refer to Interlink TCPaccess publications for details.  
644  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5107E (S/390)  
Unable to initialize CLIO/S (IBM)TCP/IP driver - error binding acceptor  
socket socket number (rc = code).  
Explanation: The server’s TCP/IP communications driver detects an error while  
attempting to bind the acceptor socket.  
System Action: The server ends the TCP/IP acceptor process. Server operation  
continues without support for the TCP/IP COMMmethod. The server tries to restart  
the acceptor process periodically.  
User Response: Check that TCP/IP is running and that TCPName, in the options  
file, matches the name of the target TCP/IP address space.  
ANR5108E (S/390)  
The CLIO/S functions have not been linked into this module.  
Explanation: The server cannot find the CLIO/S functions required to support  
CLIO (IBM)TCP/IP communications.  
System Action: The connection to the server fails.  
User Response: The cause of this error is the omission of the required  
post-SMP/E link-edit step to merge CLIO functions from  
SYS1.SFCFLIB(FCFIADSM). Before retrying the operation, ensure that your  
installation has performed the required post install link-edit step. Find the ADSM  
SAMPLIB and use member ANRCLIOK for an example of the required  
post-SMP/E link edit to load ANRSERV with CLIO/S communication code.  
ANR5109E (S/390)  
The CLIO/S communication driver cannot be started.  
Explanation: The server is unable to start the CLIO/S communication driver  
because either TCPPort and CLIOPort server options are the same value or  
TCPName is coded with *NONE*.  
System Action: The CLIO/S communication option will not be available and  
server initialization continues.  
User Response: Check the server options file to ensure CLIOPort and TCPPort  
values are different. If the CLIOPort and TCPPort options are specified correctly,  
check the TCPName option to ensure *NONE* is not coded for this option. Specify  
a unique CLIOPort value and ensure a valid TCPName parameter is coded to allow  
the (IBM)TCP/IP CLIO/S communication driver to start. CLIOPort has no default  
value; however, TCPPort and TCPName default to 1500 and TCPIP respectively.  
This message can be eliminated if CLIO/S communication is not required by  
removing the CLIOPort option from the server option file and recycling the server.  
Tivoli Storage Manager Messages  
645  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5110I (S/390)  
3270 Dial-in driver ready for connection with clients.  
Explanation: The server’s 3270 dial-in communications driver is ready to receive  
connection requests from clients.  
System Action: Server operation continues. Support for the 3270 COMMmethod is  
enabled.  
User Response: None.  
ANR5111E (S/390)  
Unable to initialize 3270 dial-in driver - error defining GRAF devices.  
Explanation: The server’s 3270 dial-in communications driver is unable to define  
one or more CP GRAF devices, and is therefore unable to initialize itself.  
System Action: Server initialization fails.  
User Response: Contact your service representative.  
ANR5112W (S/390)  
Unable to define additional GRAF devices for dial-in.  
Explanation: The server’s 3270 dial-in communications driver is unable to define  
additional CP GRAF devices, and may not be able to accept subsequent connections  
from clients.  
System Action: Server operation continues.  
User Response: Contact your service representative.  
ANR5113W (S/390)  
3270 dial-in session terminated - insufficient memory.  
Explanation: A 3270 dial-in connection request has been refused by the server’s  
3270 communications driver because sufficient memory is not available to construct  
a session.  
System Action: Server operation continues.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
2. On MVS, increase the size of the REGION parameter on the EXEC or JOB  
statement of the JCL used to start the server.  
646  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
ANR5114W (S/390)  
3270 dial-in session terminated - device does not support structured fields.  
Explanation: The server’s 3270 communications driver has refused a client  
connection request because the 3270 device initiating the connection does not  
support structured fields.  
System Action: Server operation continues.  
User Response: Retry the 3270 connection from a device that properly supports  
structured fields.  
ANR5115W (S/390)  
3270 dial-in session terminated - emulator not supported.  
Explanation: The server’s 3270 dial-in communications driver has refused a  
connection request from a client, because the client’s 3270 emulator does not or is  
not configured for the level of 3270 extended data stream support that the server  
requires.  
System Action: Server operation continues.  
User Response: Retry the 3270 connection by using a supported emulator  
program, such as the OS/2 Communications Manager, or the IBM Personal  
Communications/3270 program.  
ANR5116I (S/390)  
3270 Dial-in driver unable to start. Server terminating.  
Explanation: The server is unable to start the thread that monitors the status of the  
3270 dial-in communications driver.  
System Action: The server shuts down.  
Tivoli Storage Manager Messages  
647  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If sufficient storage is available when this error occurs, contact  
your service representative. Otherwise for VM, ensure that the storage for the server  
virtual machine is at least 128MB. For MVS, ensure the region size parameter on  
the JCL is at least 128MB.  
ANR5117I (S/390)  
ANR5118I (S/390)  
ANR5120I (S/390)  
3270 Dial-in driver terminated.  
Explanation: The 3270 dial-in communications driver has shut down.  
System Action: Server operation continues. Support for the 3270 COMMmethod is  
disabled. The server periodically tries to restart the 3270 dial-in communications  
driver.  
User Response: None.  
3270 Dial-in driver starting.  
Explanation: The server is reporting that it is in the process of starting the 3270  
dial-in communications driver.  
System Action: The server tries to initiate a process that will monitor the status of  
the 3270 dial-in communications driver.  
User Response: None.  
APPC driver unable to start. Server terminating.  
Explanation: The server is unable to start the thread that monitors the status of the  
APPC communications driver.  
System Action: The server shuts down.  
User Response: If sufficient storage is available when this error occurs, contact  
your service representative. Otherwise for VM, ensure that storage for the server  
virtual machine is at least 128MB. For MVS, ensure the region size parameter on  
the JCL is at least 128MB.  
ANR5121I (S/390)  
APPC driver ready for connections with clients on resource resource name.  
Explanation: The server’s APPC communications driver is reporting that it is  
ready to receive connection requests from clients.  
System Action: Server operation continues. Support for the SNALU6.2  
COMMmethod is enabled.  
648  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR5122I (S/390)  
ANR5123I (S/390)  
ANR5124E (S/390)  
APPC driver terminated.  
Explanation: The APPC communications driver has shut down.  
System Action: Server operation continues. Support for the SNALU6.2  
COMMmethod is disabled. The server periodically tries to restart the APPC  
communications driver.  
User Response: None.  
APPC driver starting.  
Explanation: The server is reporting that it is in the process of starting the APPC  
communications driver.  
System Action: The server tries to initiate a thread that will monitor the status of  
the APPC communications driver.  
User Response: None.  
APPC driver unable to declare as resource resource name, rc code, reason  
reason.  
Explanation: The server cannot connect to the *IDENT (the Identify System  
Service) to identify itself as the resource manager for the resource specified.  
System Action: Server operation continues. Support for the SNALU6.2  
COMMmethod is disabled. The server periodically tries to restart the APPC  
communications driver.  
User Response: Ensure that the following IUCV statement is present in the CP  
directory entry for the server: IUCV *IDENT appc-resource GLOBAL REVOKE.  
ANR5125E (S/390)  
APPC connection terminated - error code accepting connect request.  
Explanation: The server’s APPC communications driver is unable to accept a new  
connection from a client, because error code has been received from the IUCV  
ACCEPT function.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
649  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: For a description of the IUCV ACCEPT error code, refer to the  
IUCV documentation in the CP Programming Services publication for your specific  
operating system.  
ANR5126W (S/390)  
APPC connection terminated - server HALT in progress.  
Explanation: The server’s APPC communications driver refuses a request for a  
client connection because the HALT command has been entered.  
System Action: The server rejects the session and proceeds with HALT command  
processing.  
User Response: None.  
ANR5127W (S/390)  
APPC connection terminated - insufficient memory.  
Explanation: An IUCV connection request is refused by the server’s APPC  
communications driver because sufficient memory is not available to construct a  
session.  
System Action: Server operation continues.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. On VM, increase the size of the server’s virtual machine. This requires that the  
default storage size be updated in the server’s CP directory entry.  
2. On MVS, increase the size of the REGION parameter on the EXEC or JOB  
statement of the JCL used to start the server.  
3. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
4. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
650  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5128E (S/390)  
Unable to allocate session number for LU LU ID.  
Explanation: The server is unable to assign a session number to the incoming  
session.  
System Action: Server operation continues. The server rejects the incoming  
session.  
User Response: If the MAXSESSIONS statement in the server options file has  
been set correctly, the end-user (client) must wait until there is a free session before  
retrying to connect with the server. If the MAXSESSIONS statement is in error,  
shut down the server, correct the MAXSESSIONS statement, restart the server, and  
have the client retry to connect with the server.  
ANR5129W (S/390)  
VTAM APPC (LU62) conversation terminated - server HALT in progress.  
Explanation: The server’s APPC communications driver rejects a conversation  
because the HALT command has been entered.  
System Action: The server rejects the conversation and proceeds with HALT  
command processing.  
User Response: None.  
ANR5130W (S/390)  
VTAM APPC (LU62) conversation (conversation ID) with LU LU ID terminated  
- insufficient memory.  
Explanation: An APPC conversation has been terminated by the server’s APPC  
communications driver because sufficient memory is not available to support this  
conversation.  
System Action: Server operation continues. The conversation is deallocated.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. Increase the size of the REGION parameter on the JOB or EXEC statement of  
the JCL used to start the server.  
2. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
Tivoli Storage Manager Messages  
651  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
ANR5131I (S/390)  
APPC driver terminated as requested.  
Explanation: The server’s APPC communications driver is reporting that it is  
terminating as requested.  
System Action: Server operation continues with support for the SNALU6.2  
COMMmethod disabled.  
User Response: None.  
ANR5132W (S/390)  
VTAM APPC (LU62) support is not available with current session.  
Explanation: The server’s VTAM APPC (LU6.2) communications driver is not  
available. Clients that use the SNALU6.2 communications method cannot establish a  
session with the server. Refer to ANR5071W, which was displayed prior to this  
message, for additional information. If the SNALU6.2 communication method is not  
used, ignore this message and message ANR5071W.  
System Action: Server operation continues without support for the SNALU6.2  
COMMmethod.  
User Response: Verify that the server application is defined correctly to VTAM.  
APPC=YES must be specified with the VTAM APPL macro when defining the  
server application when SNALU6.2 support is used.  
ANR5133W (S/390)  
VTAM APPC (LU62) connect request rejected.  
Explanation: A client’s VTAM APPC (LU6.2) connect request was rejected  
because the LU6.2 communications driver is not available. This process may be the  
result of the server application not being defined correctly to VTAM. The  
application must be defined with APPC=YES with the APPL macro to enable  
SNALU6.2 support on the server.  
System Action: VTAM message IST663I and other related messages are  
displayed; server operation continues.  
652  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Verify that the server application is defined correctly to VTAM.  
APPC=YES must be specified with the VTAM APPL macro when defining the  
server application.  
ANR5140I (S/390)  
ANR5148I (S/390)  
ANR5200S (S/390)  
HTTP (IBM) communications is listening for clients on port port number.  
Explanation: The server’s HTTP (IBM) TCP/IP communications driver is ready to  
receive connection requests from Web clients.  
System Action: Server operation continues. Support for Web Client HTTP  
communication is enabled.  
User Response: None.  
HTTP (TCPaccess) driver is listening for clients on port port number.  
Explanation: The server’s HTTP (TCPaccess) TCP/IP communications driver is  
ready to receive connection requests from Web clients.  
System Action: Server operation continues. Support for Web Client HTTP over  
TCPaccess is enabled.  
User Response: None.  
Unable to connect to the *MSG System Service, rc = code.  
Explanation: The server receives return code code from the IUCV CONNECT  
function when connecting to the *MSG System Service.  
System Action: The server shuts down.  
User Response: Determine the cause of the error code, correct the problem, and  
restart the server. For a description of the reported error code, refer to the IUCV  
documentation in the CP Programming Services publication, or the publication for  
your operating system that contains documentation for the IUCV CONNECT  
function.  
ANR5201S (S/390)  
Error code from *MSG System Service path path ID.  
Explanation: An error occurs on the IUCV path to the *MSG System Service.  
System Action: The server shuts down.  
User Response: Determine the cause of the error code, correct the problem, and  
restart the server. For a description of the reported error code, refer to the IUCV  
Tivoli Storage Manager Messages  
653  
Download from Www.Somanuals.com. All Manuals Search And Download.  
documentation in the CP Programming Services publication, or the publication for  
your operating system that contains IUCV documentation.  
ANR5202E (S/390)  
Unable to communicate with any Notify user ID.  
Explanation: The server is unable to send a message to any user ID specified on  
the NOTIFY option in the DSMSERV OPT file.  
System Action: Server operation continues.  
User Response: Have someone with an authorized NOTIFY user ID log on to the  
system.  
ANR5203E (S/390)  
Unable to communicate with any Mount Operator.  
Explanation: The server is unable to send a message to any user ID specified on  
the MOUNTOP option in the DSMSERV OPT file.  
System Action: Server operation continues.  
User Response: Have someone with an authorized MOUNTOP user ID log on to  
the system.  
ANR5204I (S/390)  
Autolog-response  
Explanation: The result of the XAUTOLOG command for the mount exit virtual  
machine is Autolog-response.  
System Action: Server operation continues.  
User Response: None.  
ANR5205I (S/390)  
From userid: msg.  
Explanation: The message msg has been received from a nonauthorized user ID  
userid.  
System Action: Server operation continues.  
User Response: If the user ID userid is a server mount operator, ensure that the  
user ID is in the MOUNTOP list in the server options file.  
654  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5208I (S/390)  
Dismounting volume volser (updated).  
Explanation: The volume volser is dismounted after being updated (written to) by  
the server. Possible reasons for the dismount include:  
The volume was found idle and the drive was needed for another volume  
The volume is dismounted as a result of the DISMOUNT VOLUME command  
The volume is dismounted because of a previously reported error condition.  
System Action: Server operation continues.  
User Response: None.  
ANR5209I (S/390)  
Dismounting volume volser (read-only access).  
Explanation: The volume volser is dismounted after read-only access by the  
server. Possible reasons for the dismount include:  
The volume was found idle and the drive was needed for another volume  
The volume is dismounted as a result of the DISMOUNT VOLUME command  
The volume is dismounted because of a previously reported error condition.  
System Action: Server operation continues.  
User Response: None.  
ANR5210I (S/390)  
Request number: Mount devclass volume ID at vaddr mode within number of  
minutes minutes.  
Explanation: The server has requested a volume be mounted.  
System Action: The running task waits until the mount is satisfied or canceled.  
User Response: Use the DSMOP command to satisfy or cancel the mount request.  
ANR5211I (S/390)  
Request number: Mount devclass volume ID at vaddr mode (format) within number  
of minutes minutes.  
Explanation: The server has requested a volume with a specific format be  
mounted.  
System Action: The running task waits until the mount is satisfied or canceled.  
User Response: Use the DSMOP command to satisfy or cancel the mount request.  
Tivoli Storage Manager Messages  
655  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5212I (S/390)  
Request number: Mount devclass volume ID at vaddr mode via Exit Machine  
machine name.  
Explanation: The server has requested a volume be mounted.  
System Action: The running task waits until the mount is satisfied or canceled.  
User Response: Use the DSMOP command to satisfy or cancel the mount request.  
ANR5213I (S/390)  
Request number: Mount devclass volume ID at vaddr mode (format) via Exit  
Machine machine name.  
Explanation: The server has requested a volume with a specific format be  
mounted.  
System Action: The running task waits until the mount is satisfied or canceled.  
User Response: Use the DSMOP command to satisfy or cancel the mount request.  
ANR5214I (S/390)  
ANR5215I (S/390)  
ANR5216I (S/390)  
Request number: Mount devclass volume ID at vaddr mode waiting for available  
Exit Machine.  
Explanation: The server has requested a volume be mounted.  
System Action: The running task waits until the mount is satisfied or canceled.  
User Response: Use the DSMOP command to satisfy or cancel the mount request.  
Request number: Mount devclass volume ID at vaddr mode (format) waiting for  
available Exit Machine.  
Explanation: The server has requested a volume be mounted.  
System Action: The running task waits until the mount is satisfied or canceled.  
User Response: Use the DSMOP command to satisfy or cancel the mount request.  
Type volser is expected to be mounted (mode).  
Explanation: The server requires the volume volser be in read/write or read/only  
mode as indicated by mode on a device type indicated by type.  
System Action: Server operation continues.  
656  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Locate the specified volume and be prepared to make it available  
to the server.  
ANR5217I (S/390)  
ANR5218I (S/390)  
ANR5220I (S/390)  
ANR5221I (S/390)  
Dismounting volume volser - retention minute mount retention expired.  
Explanation: The volume volser is dismounted because the MOUNTRETENTION  
value retention specified for this device class has elapsed without activity on this  
volume.  
System Action: Server operation continues.  
User Response: None.  
Detaching tape device vaddr - not requested by server.  
Explanation: The virtual address vaddr is detached because it has not been  
requested by the server.  
System Action: Server operation continues.  
User Response: Check the virtual address requested by the server for tape mounts.  
Reissue the CP ATTACH command and specify the correct virtual address.  
Deleting type volser from Storage Pool pool.  
Explanation: The volume volser of device type type has been removed from  
storage pool pool.  
System Action: Server operation continues.  
User Response: The server no longer uses the volume specified. You can return  
the volume to the scratch pool.  
Request: Delete type volser via Exit Machine userid.  
Explanation: The deletion of volume volser of device type type is scheduled for  
Mount Exit Virtual Machine userid as request number request.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
657  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5222I (S/390)  
Request: Delete type volser waiting for available Exit Machine.  
Explanation: The deletion of volume volser of device type type is waiting for an  
available Mount Exit Virtual Machine userid as request number request.  
System Action: Server operation continues.  
User Response: None.  
ANR5223E (S/390)  
Deletion Exit for volser (storage pool pool) failed - unknown Rc=rc.  
Explanation: The deletion of volume volser in storage pool pool fails.  
System Action: Server operation continues.  
User Response: Contact service representative.  
ANR5224E (S/390)  
Deletion Exit for volser (storage pool pool) failed - ExitRc=rc,  
Rc=abend-indicated.  
Explanation: The deletion of volume volser in storage pool pool fails.  
System Action: Server operation continues.  
User Response: If the exit return code rc is nonzero, check the documentation for  
the tape deletion exit specified in the server options file. If the tape deletion exit has  
abended, the indicator abend-indicated is nonzero.  
ANR5225E (S/390)  
Deletion Exit for volser (storage pool pool) failed - unable to get device class  
information.  
Explanation: The deletion of volume volser in storage pool pool has failed due to  
an internal server error.  
System Action: Server operation continues.  
User Response: Contact your service representative.  
ANR5226E (S/390)  
Deletion Exit for volser (storage pool pool) failed - unable to start background  
thread.  
Explanation: The deletion of volume volser in storage pool pool has failed due to  
an internal server error.  
System Action: Server operation continues.  
658  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your service representative.  
ANR5227E (S/390)  
Deletion Exit for volser (storage pool pool) failed - insufficient memory.  
Explanation: The deletion of volume volser in storage pool pool fails due to lack  
of available storage.  
System Action: Server operation continues.  
User Response: Increase the region or virtual machine size for the server or  
reduce the MAXSESSIONS value in the server options file.  
ANR5228I (S/390)  
Deleting type volser from volume history (previous use volume).  
Explanation: The volume volser in device type type has been deleted from the  
volume history. It was previously used for previous use.  
System Action: Server operation continues.  
User Response: The server no longer tracks the volume specified. You can return  
the volume to the scratch pool.  
ANR5229W (S/390)  
RACROUTE Delete failed for volser, SAF return code System Authorized Facility  
return code, return code RACF return code, reason code RACF reason code.  
Explanation: The deletion of the profile for volume volser failed. The return codes  
and reason code are the result of a RACROUTE call. The codes are in hex. The  
SAF return code is designated as x0yy where yy is the SAF return code and x  
indicates the call as follows:  
x=1 RACROUTE REQUEST=DEFINE, TYPE=DELETE, CLASS='TAPEVOL',  
ENTITY=volume  
x=2 RACROUTE REQUEST=STAT, CLASS='TAPEVOL'  
x=3 RACROUTE REQUEST=DEFINE, TYPE=DELETE, CLASS='DATASET',  
VOLSER=volume, ENTITY=tape dataset name  
The failure of the profile deletion is not an error if the volume did not have a  
profile. No profile will exist for a volume if the server was not set up to request a  
profile (DEVCLASS parameter PROTECTION=NO) when the volume was first  
used, or if the server never used the volume.  
System Action: Server operation continues.  
User Response: If the RACF profile exists for the volume, check the system log  
for error messages to find the cause of the problem. The profile for the volume  
Tivoli Storage Manager Messages  
659  
Download from Www.Somanuals.com. All Manuals Search And Download.  
specified in the message will have to be deleted by issuing the appropriate RACF  
commands. For Information on the return codes and reason code, see External  
Security Interface (RACROUTE) Macro Reference for MVS.  
ANR5230I (S/390)  
Request number: Starting Exit Machine mountvm to mount devclass volume ID.  
Explanation: The server has autologged a mount exit virtual machine to handle a  
mount request.  
System Action: The server autologs a mount exit virtual machine.  
User Response: None.  
ANR5231I (S/390)  
Request number: Starting Exit Machine mountvm to delete devclass volume ID.  
Explanation: The server autologs a mount exit virtual machine to handle a mount  
delete request.  
System Action: The server autologs a mount exit virtual machine.  
User Response: None.  
ANR5232W (S/390)  
[XAUTOLOG] mountvm failed with return code code.  
Explanation: An error occurs during XAUTOLOG of a mount exit virtual  
machine.  
System Action: The server retries the command. If the command continues to fail,  
the mount exit machine is marked off-line, and another mount exit machine is used.  
User Response: If the mount exit machine is placed in the off-line status,  
determine the cause, correct the problem, and use the DSMOP or administrator  
READY EXIT command to restore the mount exit machine to the ready status.  
ANR5233E (S/390)  
Exit Machine mountvm taken offline - nn command attempts failed.  
Explanation: The number of XAUTOLOG attempts has exceeded an internal  
threshold. The mount exit virtual machine is no longer used.  
System Action: The server marks the mount exit virtual machine off-line.  
User Response: To make the mount exit machine available, determine the cause of  
the autolog failure. Correct the problem and use the DSMOP or administrator  
READY EXIT command to restore the mount exit machine to the ready status.  
660  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5234E (S/390)  
All Exit Machines are Offline.  
Explanation: All the defined mount exit virtual machines have been placed in the  
off-line status by the server.  
System Action: Any mount requests by the server are queued.  
User Response: Determine the cause of the autolog failures of all the mount exit  
virtual machines, correct any problems and use the DSMOP or administrator  
READY EXIT command to make the mount exit machines available.  
ANR5240E (S/390)  
Request number: Mount for volume ID has timed out.  
Explanation: The mount request has not been satisfied in the requested time.  
System Action: The server cancels the mount request.  
User Response: None.  
ANR5241E (S/390)  
Exit Machine mountvm not logged on, mount for volume ID cancelled.  
Explanation: A mount exit virtual machine has logged off without satisfying the  
server’s mount request.  
System Action: The server cancels the mount request.  
User Response: None.  
ANR5250E (S/390)  
Command: User user ID not authorized.  
Explanation: An unauthorized user has attempted to enter a DSMOP command.  
System Action: The server does not process the command.  
User Response: If the user should be authorized, add that user ID on the  
REPLYOP option in the DSMSERV OPT file.  
ANR5251E (S/390)  
Command: Invalid request number - request number.  
Explanation: A DSMOP command has been entered with an incorrect request  
number.  
System Action: The server does not process the command.  
User Response: Enter the command with the correct request number.  
Tivoli Storage Manager Messages  
661  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5252E (S/390)  
Command: No match found for this request number.  
Explanation: The request number specified by the DSMOP command is not in the  
list of outstanding mount requests.  
System Action: The server does not process the command.  
User Response: Enter the command with the correct request number.  
ANR5253E (S/390)  
Request: Invalid device address - raddr.  
Explanation: The response to server request number request has specified an  
invalid real device address raddr.  
System Action: Server operation continues.  
User Response: Respond to the request again, by specifying a valid real device  
address.  
ANR5254E (S/390)  
Command: CP command command name failed.  
Explanation: A DSMOP CANCEL REQUEST or a DSMOP REPLY command  
fails.  
System Action: The server tries to enter the CP command command and receives a  
nonzero return code.  
User Response: If you have entered a DSMOP CANCEL REQUEST, force the  
mount exit virtual machine to cancel the mount request with the FORCE option. To  
use the DSMOP CANCEL REQUEST command when running the mount exit, the  
server must have FORCE privilege. If you have entered a DSMOP REPLY  
command, attach the device to the server with the ATTACH option. To use the  
DSMOP REPLY command, the server must have ATTACH privilege.  
ANR5255E (S/390)  
Command: No matching Exit Machines were found Offline.  
Explanation: A READY EXIT command has been issued and all Mount Exit  
Virtual Machines are ready.  
System Action: Server operation continues.  
User Response: None.  
662  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5256E (S/390)  
Command: Invalid match pattern specified for Exit Machine name.  
Explanation: A DSMOP READY command has been entered specifying a user ID  
that is not a defined mount exit virtual machine.  
System Action: The server does not process the command.  
User Response: Enter the command and specify the correct mount exit virtual  
machine name.  
ANR5257I (S/390)  
Command: No requests outstanding.  
Explanation: A DSMOP QUERY MOUNTS command has been entered when no  
mount requests are outstanding.  
System Action: Server operation continues.  
User Response: None.  
ANR5258E (S/390)  
Command: Command not valid when Exit is active.  
Explanation: A DSMOP REPLY command has been entered by a reply operator  
when the mount exit is active.  
System Action: The server does not process the command.  
User Response: The DSMOP REPLY command is invalid when the mount exit is  
used. When using mount exit machines, all mount requests are issued from the  
mount exit machines using your installation’s procedures.  
ANR5259E (S/390)  
Command: Command not valid when Exit is not active.  
Explanation: A DSMOP READY command or a DSMOP QUERY EXITS  
command has been entered when the mount exit is not being used.  
System Action: The server does not process the command.  
User Response: None.  
ANR5260E (S/390)  
Command: Volume volume not found.  
Explanation: A DISMOUNT VOLUME command was issued, but the volume to  
be dismounted cannot be found.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
663  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the correct volume name is entered.  
ANR5261E (S/390)  
Command: Volume volume is not Idle.  
Explanation: A DISMOUNT VOLUME command has been issued, but the  
volume is in use and cannot be dismounted.  
System Action: Server operation continues.  
User Response: If it is necessary to dismount the volume, cancel the session or  
process that is using the volume, and reissue the command.  
ANR5262E (S/390)  
Command: Device raddr not found.  
Explanation: A DISMOUNT DEVICE command has been issued, but the device  
to be dismounted cannot be found.  
System Action: Server operation continues.  
User Response: Ensure that the correct device has been specified.  
ANR5263E (S/390)  
Command: Device raddr is not Idle.  
Explanation: A DISMOUNT DEVICE command has been issued, but the device  
is in use and cannot be dismounted.  
System Action: Server operation continues.  
User Response: If it is necessary to dismount the device, cancel the session or  
process that is using the volume, and reissue the command.  
ANR5264I (S/390)  
Command not executed - password has expired.  
Explanation: An administrative command has been issued, but the administrator’s  
password has expired.  
System Action: Server operation continues.  
User Response: Update your password by starting an administrative client session.  
Alternatively, the server system administrator may use the UPDATE ADMIN  
command to update an administrator’s password.  
664  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5265I (S/390)  
ANR5266I (S/390)  
ANR5267I (S/390)  
ANR5268I (S/390)  
Command not executed - administrator name is locked.  
Explanation: An administrative command has been issued, but the administrator’s  
user ID is locked from accessing the server.  
System Action: Server operation continues.  
User Response: The server system administrator can issue the UNLOCK ADMIN  
command to restore access to a server administrative user ID.  
Command not executed - insufficient memory.  
Explanation: An administrative command has been issued, but there is insufficient  
memory to execute the command.  
System Action: Server operation continues.  
User Response: Increase the region or virtual machine size for the server or lower  
the MAXSESSIONS parameter in the server options file and restart the server.  
Command not executed - internal error detected.  
Explanation: An administrative command has been issued, but there is a detected  
internal processing error that prevents the command from executing.  
System Action: Server operation continues.  
User Response: Look for preceding message concerning access to administrative  
user ID information within the server and contact your service representative.  
Command not executed - insufficient recovery log space.  
Explanation: An administrative command has been issued, but there is insufficient  
recovery log space to complete the database transaction.  
System Action: Server operation continues.  
User Response: To increase the amount of log space available to the server, an  
authorized admininstrator can add log volumes using the DEFINE LOGVOLUME  
command, and extend the size of the log using the EXTEND LOG command.  
Tivoli Storage Manager Messages  
665  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5269I (S/390)  
Command not executed - insufficient database space.  
Explanation: An administrative command has been issued, but there is insufficient  
database space to complete the database transaction.  
System Action: Server operation continues.  
User Response: To increase the amount of database space available to the server,  
an authorized admininstrator can add database volumes using the DEFINE  
DBVOLUME command, and extend the size of the database using the EXTEND  
DB command.  
ANR5270I (S/390)  
ANR5280I (S/390)  
ANR5281I (S/390)  
ANR5282I (S/390)  
SMFWTM macro return code 40 (buffer shortage).  
Explanation: SMFWTM completed with return code 40.  
System Action: The server continues to operate.  
User Response: Increase SMF buffer limit or disable server accounting.  
Command accepted.  
Explanation: A DSMOP REPLY command is accepted.  
System Action: The server processes the DSMOP REPLY command.  
User Response: None.  
Request request number for volume ID canceled by user ID.  
Explanation: A mount request is successfully canceled.  
System Action: The system cancels the mount request.  
User Response: None.  
Request request number for volume ID cancelled (PERM) by user ID.  
Explanation: A mount request is successfully canceled with the PERM option.  
System Action: The system cancels the mount request and marks the volume as  
unavailable.  
User Response: None.  
666  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5283I (S/390)  
ANR5284I (S/390)  
ANR5285I (S/390)  
Exit Machine mountvm status set to Ready.  
Explanation: A DSMOP READY command has been entered.  
System Action: The server changes the status of the mount exit virtual machine to  
ready.  
User Response: None.  
Requests outstanding:  
Explanation: The list of currently outstanding mount requests follows.  
System Action: The server lists all outstanding mount requests or the one specified  
on the DSMOP QUERY command.  
User Response: None.  
Exit Machine Status:  
Explanation: The list of mount exit virtual machine status follows.  
System Action: The server lists the status of all mount exit virtual machines or the  
status of the one specified on the DSMOP QUERY command.  
User Response: None.  
ANR5286I (S/390)  
Exit Machine mountvm: Ready.  
Explanation: The status of a mount exit virtual machine is ready.  
System Action: Server operation continues.  
User Response: None.  
ANR5287I (S/390)  
Exit Machine mountvm: Busy.  
Explanation: The status of a mount exit virtual machine is busy.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
667  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5288I (S/390)  
Exit Machine mountvm: Offline.  
Explanation: The status of a mount exit virtual machine is off-line.  
System Action: Server operation continues.  
User Response: None.  
ANR5289I (S/390)  
Volume volume (class class) mounted mode on raddr, status: Idle.  
Explanation: Volume volume, which is of device class class and is mounted at  
address raddr in mode mode, is eligible for dismounting or reuse.  
System Action: Server operation continues.  
User Response: None.  
ANR5290I (S/390)  
ANR5291I (S/390)  
ANR5292I (S/390)  
Volume volume (class class) mounted mode on raddr, status: In Use.  
Explanation: Volume volume, which is of device class class and is mounted at  
address raddr in mode mode, is in use by the server.  
System Action: Server operation continues.  
User Response: None.  
Volume volume (class class) mounted mode on raddr, status: Dismounting.  
Explanation: Volume volume, which is in device class class and is mounted at  
address raddr in mode mode, is in the process of dismounting.  
System Action: Server operation continues.  
User Response: None.  
number volume(s) found.  
Explanation: A QUERY MOUNT command has been issued; number volumes are  
mounted.  
System Action: Server operation continues.  
User Response: None.  
668  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5293I (S/390)  
Cancelling mount for volume volume.  
Explanation: A CANCEL MOUNT command has been issued for volume volume.  
The CANCEL command is being processed.  
System Action: Server operation continues.  
User Response: Query the activity log to verify that the mount request has been  
cancelled.  
ANR5294I (S/390)  
ANR5295I (S/390)  
ANR5296I (S/390)  
ANR5297I (S/390)  
Volume volume (class class) mounted mode, status: Idle.  
Explanation: Volume volume, which is in device class class in mode mode, is  
eligible for dismounting or reuse.  
System Action: Server operation continues.  
User Response: None.  
Volume volume (class class) mounted mode, status: In Use.  
Explanation: Volume volume, which is in device class class in mode mode, is in  
use by the server.  
System Action: Server operation continues.  
User Response: None.  
Volume volume (class class) mounted mode, status: Dismounting.  
Explanation: Volume volume, which is in device class class in mode mode, is in  
the process of dismounting.  
System Action: Server operation continues.  
User Response: None.  
Volume volume (class class) mounted mode, status: In Retry.  
Explanation: Volume volume, which is in device class class in mode mode, is  
currently in RETRY. An attempt is being made to re-establish communications with  
another server. If the volume remains in retry status for the amount of time  
specified by the device class retry period, the operation will fail and the volume will  
be automatically dismounted.  
Tivoli Storage Manager Messages  
669  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: None.  
ANR5300I (S/390)  
Verifying volume label volume ID on device real address.  
Explanation: The server is verifying the volume label of a mounted read/write  
volume again prior to dismounting the volume.  
System Action: The server performs the reverification of the volume label as an  
integrity check of the volume.  
User Response: None.  
ANR5301I (S/390)  
Request number: Verifying volume label volume ID on device device.  
Explanation: The server is verifying the volume label of a mounted volume  
during the mount process.  
System Action: The server ensures that the volume mounted is acceptable.  
User Response: None.  
ANR5302I (S/390)  
Request number: Assigning volume volume ID to SCRTCH.  
Explanation: The server has assigned the mounted volume to be used as the  
requested scratch volume.  
System Action: The server dynamically adds the volume label of the mounted  
volume to the storage pool.  
User Response: None.  
ANR5303I (S/390)  
Request number: Assigning volume volume ID to EXPORT.  
Explanation: The server has assigned the mounted volume to be used as the  
requested export volume.  
System Action: The server uses the volume for the EXPORT operation.  
User Response: None.  
670  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5304I (S/390)  
Request number: Assigning volume volume ID to IMPORT.  
Explanation: The server has assigned the mounted volume to be used as the  
requested import volume.  
System Action: The server uses the volume for the IMPORT operation.  
User Response: None.  
ANR5305E (S/390)  
Request number: Device real address is not a supported devclass device.  
Explanation: A device is attached to the server to satisfy a mount request, but it is  
the wrong device class. For example, a CARTRIDGE device has been used when  
the request is for a REEL device.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Make sure the device used to satisfy a mount request is the same  
type as the device requested.  
ANR5306E (S/390)  
Request number: Device real address not capable.  
Explanation: The server requested a volume with a specific density or format. The  
device used to satisfy the mount cannot write using the requested density or format.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Mount the volume on a device capable of the requested density or  
format.  
ANR5307E (S/390)  
Request number: Volume on real address is write protected.  
Explanation: The mounted volume is not enabled for writing.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Enable the volume for writing and reply to the mount again.  
ANR5308E (S/390)  
Request number: Volume on real address is not write protected.  
Explanation: The mounted volume is not write protected.  
Tivoli Storage Manager Messages  
671  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Disable the volume for writing and reply to the mount again.  
ANR5309E (S/390)  
Request number: Volume on real address has no VOL1 label.  
Explanation: The mounted volume does not have a standard label.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Make sure you are mounting the correct volume. All volumes  
must have a standard VOL1 label.  
ANR5310E (S/390)  
Volume on real address has no VOL1 label - volume integrity compromised.  
Explanation: During volume unmount label reverification, the server finds no  
VOL1 label.  
System Action: The server marks the volume as unavailable.  
User Response: The volume cannot be used because the VOL1 label has been  
overwritten. All active data on the volume cannot be recovered. Delete the volume  
from the storage pool with the DELETE VOLUME command by using the  
DISCARD=YES option. To use this volume again, the volume must be initialized  
with a VOL1 label. The volume may then be redefined in the storage pool.  
ANR5311E (S/390)  
Request number: Volume label on raddr (volume ID found) does not match volume  
ID expected.  
Explanation: During mount processing, the volume ID read on the mounted  
volume does not match the specifically requested partially full volume.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Make sure you are mounting the correct volume.  
ANR5312E (S/390)  
Volume label on raddr (volume ID found) does not match volume ID expected -  
volume integrity compromised.  
Explanation: During volume unmount label reverification, the server finds a  
different VOL1 label.  
672  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server marks the volume as unavailable.  
User Response: The volume cannot be used because the VOL1 label has been  
overwritten by a different VOL1 label. All active data on the volume cannot be  
recovered. Delete the volume from the repository with the DELETE VOLUME  
command by using the NORECLAIM option. To use this volume again, the volume  
must be initialized with a VOL1 label. The volume may then be redefined in the  
repository.  
ANR5313I (S/390)  
Request number: Mount for volume ID complete on device real address.  
Explanation: A volume mount has successfully completed.  
System Action: The task waiting for a volume mount resumes.  
User Response: None.  
ANR5314E (S/390)  
Request number: Permanent I/O error on device real address.  
Explanation: A permanent I/O error occurred when the device was opened.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Mount the volume on a different device.  
ANR5315E (S/390)  
Read Data Check on device real address.  
Explanation: A data check occurred during a read operation.  
System Action: The server redrives the I/O by using Diagnose X'20' or Diagnose  
X'A8'.  
User Response: None.  
ANR5316E (S/390)  
Write Data Check on device real address.  
Explanation: A data check occurred during a write operation.  
System Action: The server redrives the I/O by using Diagnose X'20' or Diagnose  
X'A8'.  
User Response: None.  
Tivoli Storage Manager Messages  
673  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5317I (S/390)  
Make device real address ready.  
Explanation: The device is in a not ready condition.  
System Action: The server sends an intervention required message to the mount  
operator user IDs listed in the DSMSERV OPT file.  
User Response: Make the device ready.  
ANR5318I (S/390)  
ANR5319I (S/390)  
ANR5320I (S/390)  
Intervention cleared on device real address.  
Explanation: The device requiring operator intervention is now ready.  
System Action: The task waiting for the device continues.  
User Response: None.  
Intervention required on device real address.  
Explanation: The device requires operator intervention.  
System Action: The task waits until the device is made ready.  
User Response: Make the device ready.  
Volume volume ID already in use.  
Explanation: A tape volume has been mounted for use by the server; after  
mounting the volume, the server determined that the volume was already in use by  
the server and could not be used to satisfy the current mount request.  
System Action: The server dismounts the volume, detaches the device, and  
reissues the original request.  
User Response: Mount a volume not already in use by the server.  
ANR5321I (S/390)  
End of volume reached for volume ID on device real address.  
Explanation: During processing of a read/write tape volume, the end of the tape  
volume has been reached.  
System Action: The volume is marked read-only and kept mounted for later use.  
User Response: None.  
674  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5322I (S/390)  
Permanent error on volume volume ID on device real address.  
Explanation: During processing of a tape volume, a permanent I/O error occurred.  
System Action: The server places the volume in an I/O error state. If the volume  
was being used for writing, it is marked read-only.  
User Response: None.  
ANR5323I (S/390)  
Assigning volume volume ID to SCRTCH.  
Explanation: The server has assigned the mounted volume to be used as the  
requested scratch volume.  
System Action: The server dynamically adds the volume label of the mounted  
volume to the storage pool.  
User Response: None.  
ANR5324I (S/390)  
ANR5325I (S/390)  
ANR5326E (S/390)  
Assigning volume volume ID to EXPORT.  
Explanation: The server has assigned the mounted volume to be used as the  
requested export volume.  
System Action: The server uses the volume for the EXPORT operation.  
User Response: None.  
Assigning volume volume ID to IMPORT.  
Explanation: The server has assigned the mounted volume to be used as the  
requested import volume.  
System Action: The server uses the volume for the IMPORT operation.  
User Response: None.  
Volume label on raddr (volume ID found) does not match volume ID expected.  
Explanation: During mount processing, the volume ID read on the mounted  
volume does not match the specifically requested partially full volume.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
Tivoli Storage Manager Messages  
675  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Make sure you are mounting the correct volume.  
ANR5327I (S/390)  
ANR5328I (S/390)  
ANR5329I (S/390)  
ANR5330I (S/390)  
ANR5331S (S/390)  
Request number: Assigning volume volume ID to DUMPDB.  
Explanation: The server has assigned the mounted volume to be used as the  
requested DUMPDB volume.  
System Action: The server uses the volume for the DUMPDB operation.  
User Response: None.  
Request number: Assigning volume volume ID to LOADDB.  
Explanation: The server assigns the mounted volume for use as the requested  
LOADDB volume.  
System Action: The server uses the volume for the LOADDB operation.  
User Response: None.  
Assigning volume volume ID to DUMPDB.  
Explanation: The server assigns the mounted volume for use as the requested  
DUMPDB volume.  
System Action: The server uses the volume for the DUMPDB operation.  
User Response: None.  
Assigning volume volume ID to LOADDB.  
Explanation: The server assigns the mounted volume for use as the requested  
LOADDB volume.  
System Action: The server uses the volume for the LOADDB operation.  
User Response: None.  
Volume volume ID damaged - recovery required.  
Explanation: The server detects an error on the specified volume. The volume has  
been unexpectedly repositioned during write processing. Data may have been lost.  
676  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server halts the process that is using the volume and marks  
the volume as read-only.  
User Response: For EXPORT, DBBACKUP, or DBDUMP tapes, restart the  
export, backup, or dump operation. Do not use the tape for an IMPORT,  
DBRESTORE, or DBLOAD operation. If the tape is a storage pool volume, you can  
attempt to recover the data with the following steps:  
1. To identify any missing data, issue the AUDIT VOLUME command by  
specifying FIX=NO.  
2. If recoverable data exists on the tape, delete references to the missing data from  
the database by issuing the AUDIT VOLUME command and specifying  
FIX=YES.  
3. Issue the MOVE DATA command to remove all data from the damaged tape  
after the AUDIT (FIX=YES) has completed.  
NOTE: Issuing an audit command on a damaged volume can result in a large  
number of logged messages.  
ANR5332I (S/390)  
Request number: Assigning volume volume ID to DBBKUP.  
Explanation: The server assigns the mounted volume for use as the requested  
DBBKUP volume.  
System Action: The server uses the volume for the DBBKUP operation.  
User Response: None.  
ANR5333I (S/390)  
Assigning volume volume ID to DBBKUP.  
Explanation: The server assigns the mounted volume for use as the requested  
DBBKUP volume.  
System Action: The server uses the volume for the DBBKUP operation.  
User Response: None.  
ANR5334W (S/390)  
Volume volume ID reached end of tape.  
Explanation: The server has detected end of tape for the specified volume. The  
volume reached the end of tape before the maximum capacity value specified in the  
device class was reached.  
System Action: The server requests another volume if one is available. The current  
process stops writing to the specified volume.  
Tivoli Storage Manager Messages  
677  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reduce the maximum capacity in the device class. The QUERY  
VOLUME command will indicate the actual capacity of the volume after it is full.  
Use the UPDATE DEVCLASS command to change the maximum capacity for the  
device class.  
ANR5335E (S/390)  
Volume volume ID already used.  
Explanation: A tape volume is mounted as scratch for use by the server. After  
mounting the volume, the server determines that the volume has already been used  
by the server and cannot be used to satisfy the current mount request. Mounting the  
volume as scratch may have destroyed some of the data previously written on that  
volume.  
System Action: The server dismounts the volume, detaches the device, and  
reissues the original request.  
User Response: Mount a volume not already in use by the server. The damaged  
volume must be replaced, restored, or deleted from the volume history file.  
If the volume is an Export, Database Dump or Database Backup volume that  
contains data that is no longer needed, use the DELETE VOLHISTORY  
command to make the volume available to the server for reuse.  
If the volume mounted is an Export or Database Dump, the tapes are no longer  
good and another export or dump must be taken. If the tape is a current  
Database Backup volume, a full backup must be done to insure a complete  
backup exists.  
If the volume is a storage pool volume, audit the volume. If it is a primary  
volume and a copypool exists, restore the volume. If it is a copypool volume,  
backup the storage pool again to insure a backup copy exists for all files.  
It is strongly recommended that you use the DEVCLASS EXPIRATION or  
RETENTION parameter to protect your tapes and prevent damage to tapes you  
create in the future.  
ANR5336E (S/390)  
Volume volume ID must be read-only on 3590 device.  
Explanation: The server requests a volume in a mode other than read-only. The  
3590 device that is used to satisfy the mount cannot be used to write to the volume.  
System Action: The server cancels the current operation.  
User Response: Update the volume access to READONLY or insure that a device  
of the type used to create the volume is used to satisfy the mount.  
678  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5337I (S/390)  
Assigning volume volume ID to BACKUPSET.  
Explanation: The server has assigned the mounted volume to be used as the  
requested backupset volume.  
System Action: The server uses the volume for the BACKUPSET operation.  
User Response: None.  
ANR5350E (S/390)  
Error locating block block number on device real address.  
Explanation: A Locate Block CCW failed.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: This failure may be due to a hardware problem. Reset the error  
condition with the UPDATE VOLUME command. If the problem persists, use the  
DELETE VOLUME command with the DISCARD=NO option to remove the  
volume from the storage pool.  
ANR5351E (S/390)  
Error reading BlockID on device real address.  
Explanation: A Read Block ID CCW failed.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: This failure may be due to a hardware problem. Reset the error  
condition with the UPDATE VOLUME command. If the problem persists, use the  
DELETE VOLUME command with the DISCARD=NO option to remove the  
volume from the storage pool.  
ANR5352E (S/390)  
Synchronize failed on device real address.  
Explanation: A Synchronize CCW failed.  
System Action: The server marks the volume in an I/O error condition, and  
requests another volume be mounted.  
User Response: Reply to the new mount request. Reset the error condition with  
the UPDATE VOLUME command. The integrity of the original volume may have  
been compromised. To delete the volume, issue the DELETE VOLUME command  
with the DISCARD=NO option.  
Tivoli Storage Manager Messages  
679  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5353E (S/390)  
Load Display failed on device real address.  
Explanation: A Load Display CCW failed.  
System Action: Server operation continues. No text is loaded into the display  
window.  
User Response: None.  
ANR5354E (S/390)  
Block block number sequence error on device real address.  
Explanation: During a read operation, the block ID of the block being read does  
not match the block ID stored in the data block header.  
System Action: The server places the volume in an I/O error state.  
User Response: The integrity of the volume may have been compromised. Reset  
the error condition with the UPDATE VOLUME command and attempt the  
operation on a different tape drive. If the problem persists, you can delete the  
volume with the DELETE VOLUME command, by using the DISCARD=NO  
option.  
ANR5355E (S/390)  
Reload cartridge on device real address.  
Explanation: The cartridge is not inserted correctly, or the tape is not processed  
correctly.  
System Action: The task waits until the drive is made ready. An intervention  
required message is sent to the mount operator user IDs.  
User Response: Make the drive ready.  
ANR5356E (S/390)  
Unload cartridge on device real address.  
Explanation: The drive cannot maintain tape tension and control tape movement  
during an unload operation.  
System Action: The task waits until the drive is made ready. An intervention  
required message is sent to the mount operator user IDs.  
User Response: Make the drive ready.  
680  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5357E (S/390)  
Manual Rewind/Rewind-Unload on device real address.  
Explanation: The Rewind Unload switch or the Rewind switch on the drive has  
been pressed.  
System Action: The server verifies the volume label and attempts to reposition the  
tape and continue operation. If the volume label verification fails, the server marks  
the volume in the unavailable state. If the reposition fails, the server marks the  
volume in the I/O error state.  
User Response: If the server succeeds in its recovery, no action is required. If  
recovery is unsuccessful, you can reset the error status of the volume with the  
UPDATE VOLUME command. Volume integrity may have been compromised.  
Issue the DELETE VOLUME command with the DISCARD=NO option to try to  
recover any data.  
ANR5358E (S/390)  
Request number: I/O Error at beginning of tape on real address.  
Explanation: An I/O error has occurred attempting to mount a tape volume; the  
beginning of the volume cannot be detected.  
System Action: The server places the volume in an I/O error state.  
User Response: The integrity of the volume may have been compromised. Reset  
the error condition with the UPDATE VOLUME command and attempt the  
operation on a different tape drive. If the problem persists, you can delete the  
volume with the DELETE VOLUME command, by using the DISCARD=NO  
option.  
ANR5359E (S/390)  
Request number: Cartridge Length Error on device real address.  
Explanation: A tape cartridge has been mounted that is too short for processing on  
the drive.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: Reply to the new mount request. If necessary, reset the error  
condition with the UPDATE VOLUME command. The integrity of the original  
volume may have been compromised. To delete the volume, issue the DELETE  
VOLUME command with the DISCARD=NO option.  
Tivoli Storage Manager Messages  
681  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5360E (S/390)  
ANR5361E (S/390)  
ANR5362E (S/390)  
ANR5363E (S/390)  
Request number: Cartridge Length Incompatible on device real address.  
Explanation: A tape cartridge has been mounted on a drive and the tape is too  
long to be processed on the drive or has been initialized to the wrong length.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: Reply to the new mount request. If necessary, reset the error  
condition with the UPDATE VOLUME command. The integrity of the original  
volume may have been compromised. To delete the volume, issue the DELETE  
VOLUME command with the DISCARD=NO option.  
Request number: Cartridge Format Incompatible on device real address.  
Explanation: A tape cartridge has been mounted on a drive, but the tape format  
cannot be processed on the drive.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: Reply to the new mount request. If necessary, reset the error  
condition with the UPDATE VOLUME command. The integrity of the original  
volume may have been compromised. To delete the volume, issue the DELETE  
VOLUME command with the DISCARD=NO option.  
Request number: Cartridge Length Violation on device real address.  
Explanation: A tape cartridge has been mounted on a drive but the tape is too  
long to be processed on the drive.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: Reply to the new mount request. If necessary, reset the error  
condition with the UPDATE VOLUME command. The integrity of the original  
volume may have been compromised. To delete the volume, issue the DELETE  
VOLUME command with the DISCARD=NO option.  
Request number: Cartridge Compaction Incompatible on device real address.  
Explanation: A tape cartridge has been mounted on a drive but the tape  
compression algorithm ID is not compatible with the drive.  
682  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server marks the volume in an I/O error condition and  
requests another volume be mounted.  
User Response: Reply to the new mount request. If necessary, reset the error  
condition with the UPDATE VOLUME command. The integrity of the original  
volume may have been compromised. To delete the volume, issue the DELETE  
VOLUME command with the DISCARD=NO option.  
ANR5364E (S/390)  
ANR5365E (S/390)  
ANR5366E (S/390)  
Record sequence error on device real address.  
Explanation: During processing of a tape volume, the record tape number read  
does not match that expected by the drive.  
System Action: The server marks the volume in an I/O error condition.  
User Response: This failure may be due to a hardware problem. Reset the error  
condition with the UPDATE VOLUME command. If the problem persists, use the  
DELETE VOLUME command with the DISCARD=NO option to remove the  
volume from the storage pool.  
Volume fenced on device real address.  
Explanation: During processing of a tape volume, errors have occurred that  
caused the tape drive to lose the ability to process the volume.  
System Action: The server marks the volume in an I/O error condition.  
User Response: Unload and reload the tape to reset the drive. Reset the error  
condition with the UPDATE VOLUME command. This failure may be due to a  
hardware problem. If the problem persists, use the DELETE VOLUME command  
with the DISCARD=NO option to remove the volume from the storage pool.  
Request number: Volume volume ID data set name label dsnin HDR1 label  
cannot be overwritten with Export data set name export dsn.  
Explanation: During mount processing of an EXPORT tape volume, the server  
encountered a nonblank data set name in the HDR1 label. Normally, the server  
writes the export dsn in this field.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Most tape volume initialization programs only write VOL1 label.  
If your tape volume initialization program also writes a HDR1 label, the data set  
Tivoli Storage Manager Messages  
683  
Download from Www.Somanuals.com. All Manuals Search And Download.  
name in the HDR1 label must be blank. Be sure that the volume in question is the  
proper tape volume, and reinitialize it with only a VOL1 label, or with a blank data  
set name in the HDR1 label.  
ANR5367I (S/390)  
Request number: Volume volume ID data set name label dsnin HDR1 label will  
be overwritten with Export data set name export dsn.  
Explanation: During mount processing of an EXPORT tape volume, the server  
encountered a nonblank data set name in the HDR1 label. This data set name will  
be overwritten with export dsn.  
System Action: The server continues with mount processing.  
User Response: None.  
ANR5368E (S/390)  
Request number: Volume volume ID data set name label dsnin HDR1 label  
cannot be overwritten with DUMPDB data set name dumpdb dsn.  
Explanation: During mount processing of an DUMPDB tape volume, the server  
encountered a nonblank data set name in the HDR1 label. Normally, the server  
would write the dumpdb dsn in this field.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Most tape volume initialization programs only write a VOL1  
label. If your tape volume initialization program also writes a HDR1 label, the data  
set name in the HDR1 label must be blank. Be sure the volume in question is the  
correct tape volume, and reinitialize it with only a VOL1 label, or with a blank data  
set name in the HDR1 label.  
ANR5369I (S/390)  
Request number: Volume volume ID data set name label dsnin HDR1 label will  
be overwritten with DUMPDB data set name dumpdb dsn.  
Explanation: During mount processing of an DUMPDB tape volume, the server  
encountered a nonblank data set name in the HDR1 label. This data set name will  
be overwritten with dumpdb dsn.  
System Action: The server continues with mount processing.  
User Response: None.  
684  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5370E (S/390)  
Invalid block header on device real address.  
Explanation: During a read operation, the block header of the block read does not  
contain data recognized by the server.  
System Action: The server may place the volume in an I/O error state.  
User Response: The integrity of the volume may have been compromised. Reset  
the error condition with the UPDATE VOLUME command and attempt the  
operation on a different tape drive. If the problem persists, try to audit the volume  
by using the AUDIT VOLUME command to see if any files on the volume can be  
recovered. If not, you can delete the volume with the DELETE VOLUME  
command, by using the DISCARD=NO option.  
If a LOADDB operation was being performed, specify the command syntax by  
either using a ddname or by specifying a device class name. You must use the same  
method that was used when the data base was originally dumped. Otherwise, this  
error message is displayed. Try loading the data base by using the other method of  
syntax (ddname). Also, verify that you specified the correct volume name. The  
integrity of the volume may have been compromised. In this case, the volume  
cannot be used by the LOADDB operation.  
ANR5371E (S/390)  
Request number: Volume volume ID data set name label dsnin HDR1 label  
cannot be overwritten with DBBKUP data set name dbbkup dsn.  
Explanation: During mount processing of a DBBKUP tape volume, the server  
encountered a nonblank data set name in the HDR1 label. Normally, the server  
writes the dbbkup dsn in this field.  
System Action: The server dismounts the volume, detaches the device, and  
requests the original volume again.  
User Response: Most tape volume initialization programs only write VOL1 label.  
If your tape volume initialization program also writes a HDR1 label, the data set  
name in the HDR1 label must be blank. Be sure that the volume in question is the  
proper tape volume, and reinitialize it with only a VOL1 label, or with a blank data  
set name in the HDR1 label.  
ANR5372I (S/390)  
Request number: Volume volume ID data set name label dsnin HDR1 label will  
be overwritten with DBBKUP data set name dbbkup dsn.  
Explanation: During mount processing of a DBBKUP tape volume, the server  
encountered a nonblank data set name in the HDR1 label. This data set name will  
be overwritten with dbbkup dsn.  
Tivoli Storage Manager Messages  
685  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server continues with mount processing.  
User Response: None.  
ANR5373I (S/390)  
Unable to allocate tape drive with device type device type for tape volume ID.  
Reply ’C’ (cancel), ’R’ (retry), or ’W’ (wait).  
Explanation: The server attempts to allocate a tape drive. The allocation attempt  
fails because no acceptable tape drive is available. An acceptable tape drive has the  
device type indicated in the message.  
Before more attempts are made to allocate the tape drive, the operator is prompted  
to indicate whether or not the tape drive allocation request can be satisfied. The  
device type and the VOLSER of the tape volume volser to be used for the pending  
request are provided in the message text.  
System Action: If the operator replies ’R’ (meaning retry), the server will retry the  
tape drive allocation. If no acceptable drive is available after retrying the allocation,  
the server will reissue this message.  
If the operator replies ’W’ (meaning wait), the server will retry the tape drive  
allocation. If the allocation request cannot be satisfied immediately, the server will  
wait while MVS Allocation Recovery issues message IEF238D. After IEF238D is  
issued, none of the following can occur in the server until the allocation completes  
or is canceled:  
dynamic allocations or deallocations  
file opens or closes  
tape volume changes between read mode and write mode  
If the operator replies ’C’ (meaning cancel), the server will fail the tape drive  
allocation and its associated server request.  
Any other reply will cause the server to reissue this message. Determine if there are  
any tape drives which can be used to satisfy this request (either online or offline)  
prior to responding to this message.  
User Response: None.  
ANR5374I (S/390)  
Tape volume volume ID on real address real address has had an unsolicited  
interrupt, and may have been dismounted.  
Explanation: An unsolicited interrupt is received for the drive where the volume  
is mounted. The drive is not ready or its state cannot be determined, so the tape  
may have been dismounted.  
686  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: If the server can recover without possibility of data loss, it will  
reverify the label and continue operations. If the label is not verified or data loss is  
possible with continued use, the next operation will fail and the tape will be  
dismounted.  
User Response: Check the tape drive.  
ANR5404I (S/390)  
SERVER volume volume name mounted.  
Explanation: The server has mounted the given volume.  
System Action: Read or write operations, or both, will commence for the volume.  
User Response: None.  
ANR5405I (S/390)  
End-of-volume reached for SERVER volume volume name.  
Explanation: The server has detected an end-of-volume condition for the given  
volume.  
System Action: The volume is marked full. If more data must be stored, the server  
accesses another volume.  
User Response: None.  
ANR5410I (S/390)  
FILE volume volume name mounted.  
Explanation: The server has opened the given file to simulate a tape volume.  
System Action: Read or write operations, or both, will commence for the volume.  
User Response: None.  
ANR5411I (S/390)  
End-of-volume reached for FILE volume volume name.  
Explanation: The server has detected an end-of-volume condition for the given  
volume.  
System Action: The volume is marked full. If more data must be stored, the server  
accesses another volume.  
User Response: None.  
Tivoli Storage Manager Messages  
687  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5412I (S/390)  
FILE volume volume name MAXCAPACITY larger than allowed maximum.  
Overriding maximum capacity to FILE maximum capacityMB.  
Explanation: The maximum capacity specified for the listed volume is larger than  
the maximum allowed for the FILE device class.  
System Action: The volume capacity is set to the maximum allowed for the FILE  
device class.  
User Response: Update the device class of the volume MAXCAPACITY value to  
less than or equal the maximum allowed for the FILE device class.  
ANR5413E (S/390)  
Dynamic allocation of FILE volume volume on unit=unit volser=volser returned  
rc=rc, info code=info code, error code=error code.  
Explanation: The dynamic allocation of FILE volume volume on unit unit and  
volume serial volser fails. The server uses the unit and volser device class  
parameters when allocating new FILE volumes, and always catalogs the actual MVS  
data sets. If these parameters are not defined, Dynamic Allocation uses system  
defaults to select a device on which to create the MVS sequential data set.  
For previously allocated FILE volumes, the server allows Dynamic Allocation to  
locate the actual MVS data set using catalog services.  
The return code rc, information code info code and error code error code are in  
decimal and can be found in the Dynamic Allocation section of MVS/ESA  
Programming: Authorized Assembler Services Guide.  
System Action: Server operation continues.  
User Response: For new FILE volumes, verify that all device class parameters are  
defined correctly and are compatible, and that space is available on the target  
DASD.  
ANR5414E (S/390)  
Error error code returned while opening FILE volume volume  
Explanation: The BSAM OPEN fails. Error code error code is returned. Check  
for accompanying MVS error messages.  
Error codes greater than eight are MVS ABEND codes, documented in MVS/ESA  
System Codes, GC28-1486.  
System Action: Server operation continues.  
User Response: For previously allocated FILE volumes, verify that the MVS data  
set used for the FILE volume exists on the physical device designated by the  
catalog. Check the accompanying MVS system messages.  
688  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5415W (S/390)  
SFS CSL call CSL name failed with return code rc, reason code rs. optional (file  
or directory being processed)  
Explanation: A call to an SFS CSL routine failed.  
System Action: See following server messages.  
User Response: Check the return and reason codes in the System Messages and  
Codes manual, Callable Services Library (CSL) Reason Codessection, for  
information on the problem and on the action needed to correct it.  
ANR5416E (S/390)  
Minidisk device class cannot be used with SFS file file name.  
Explanation: A device class of DEVTYPE=FILE is defined with FILEMODE=  
where the file mode letter is associated with an SFS directory. Device classes  
defined with DEVTYPE=FILE and FILEMODE= parameters can only be associated  
with an accessed minidisk (CMS file mode letter A-Z).  
System Action: File is not used.  
User Response: When using a minidisk, define the DEVTYPE=FILE device class  
with the FILEMODE= parameter. When using an SFS directory, use the  
DIRECTORY= parameter.  
ANR5417E (S/390)  
File file name already exists, it cannot be created.  
Explanation: The server attempted to create a new file using file name but  
received indication that the file already exists. The server will create a new file after  
it determines that the file named file name is not in its database. The server will  
append to an existing file with the name file name only if it exists in its database.  
The server will not overwrite an existing file.  
System Action: File is not used.  
User Response: The file named file name must either be renamed or erased.  
ANR5418E (S/390)  
File file name cannot be used.  
Explanation: The server found that the file file name exists in its database, but  
either was accessed as read-only or the file did not exist on the minidisk identified  
by the file mode letter or the file did not exist in the SFS directory.  
System Action: File is not used.  
Tivoli Storage Manager Messages  
689  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Make sure the minidisk is accessed with the file mode letter  
specified for the device class defined with DEVTYPE=FILE FILEMODE=?. If the  
file is in an SFS directory, make sure the SFS directory still exists and the server  
user ID has been granted read/write authority to the directory and to the file named  
command. If the volume status is read/write and the volume is not full, write access  
is required. If the file does not exist, the server cannot use the volume. Storage  
volumes should be deleted using the DELETE VOLUME command with  
DISCARDDATA=YES. Volumes for IMPORT, LOAD or RESTORE DB cannot be  
used.  
ANR5419E (S/390)  
Filemode or directory filemode or directory name cannot be used.  
Explanation: The server determined that a minidisk with the file mode letter  
filemode or that the SFS directory directory name were not available for use.  
System Action: Server operation continues but file is not used.  
User Response: Ensure that a minidisk is accessed with the file mode letter  
filemode or that an SFS directory directory directory exists and that the server user  
ID has been granted read/write authority to the directory and all files in that  
directory.  
ANR5420W (S/390)  
FILE FILE name not deleted from system, return code return code.  
Explanation: A volume associated with a device class defined with  
DEVTYPE=FILE was deleted from the server, but the associated CMS file or MVS  
data set FILE name could not be deleted.  
System Action: Server operation continues. No other attempts will be made to  
delete the volume from the system.  
User Response: If the volume was created and never used, a CMS file or an MVS  
dataset may not have been created and no action is required. If the CMS file or the  
MVS dataset FILE name exists it will have to be deleted manually.  
ANR5450E (S/390)  
Error opening filespec.  
Explanation: An error occurred while attempting an open operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the open  
operation failed. Correct the problem and restart the process.  
690  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5451E (S/390)  
ANR5452E (S/390)  
ANR5453E (S/390)  
An error (error code) occurred during a write operation.  
Explanation: An error occurred while attempting a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation failed. Correct the problem and restart the process.  
An error (error code) occurred during a read operation.  
Explanation: An error occurred while attempting a read operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the read  
operation failed. Correct the problem and restart the process.  
Device type volume volume name cannot be overwritten by EXPORT operation.  
Explanation: The specified volume already exists or contains data. The server  
does not allow new export data to be written to the volume.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested export operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the export operation.  
ANR5454E (S/390)  
Device type volume volume name cannot be overwritten by DUMPDB operation.  
Explanation: The specified volume already exists or contains data. The server  
does not allow new dump data to be written to the volume.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested dump operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the dump operation.  
Tivoli Storage Manager Messages  
691  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5455E (S/390)  
ANR5456E (S/390)  
ANR5499E (S/390)  
ANR5500E (S/390)  
Device type volume volume name cannot be overwritten by BACKUP DB  
operation.  
Explanation: The specified volume already exists or contains data. The server  
does not allow new backup data to be written to the volume.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested backup operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the backup operation.  
Device type volume volume name cannot be overwritten by BACKUPSET  
operation.  
Explanation: The specified volume already exists or contains data. The server  
does not allow new backupset data to be written to the volume.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested backupset operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the backupset operation.  
command: Required parameter was not specified parameter.  
Explanation: The command command has been issued, but without a required  
parameter. If two parameters are listed, the command requires at least one of the  
parameters.  
System Action: Server operation continues.  
User Response: Reissue the command and specify the missing parameter and any  
additional parameters that are required for the command. The HELP DEFINE or  
HELP UPDATE commands may be used to obtain syntax assistance.  
Command: Device type not specified.  
Explanation: The command command has been issued, but without the DEVTYPE  
keyword.  
System Action: Server operation continues.  
692  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command, and specify the DEVTYPE keyword and  
any additional parameters that are required for the command. The HELP DEFINE or  
HELP UPDATE commands may be used to obtain syntax assistance.  
ANR5501E (S/390)  
Command: attributeis invalid for device type.  
Explanation: The command command has been issued with an incompatible  
combination of device type and attribute.  
System Action: Server operation continues.  
User Response: Reissue the command, and specify a compatible set of attributes.  
The HELP DEFINE or HELP UPDATE commands may be used to obtain syntax  
assistance.  
ANR5502E (S/390)  
Command: LENGTHis invalid with 3480 and 3480XF formats.  
Explanation: The command command has been issued with an incompatible  
combination of device type, FORMAT, and LENGTH. A length specification is  
invalid with 3480 and 3480XF formats.  
System Action: Server operation continues.  
User Response: Reissue the command, and specify a compatible set of attributes.  
For 3480 and 3480XF formats, reenter the command without a LENGTH keyword.  
The HELP DEFINE or HELP UPDATE commands may be used to obtain syntax  
assistance.  
ANR5503E (S/390)  
Command: Invalid parameter for update - parameter.  
Explanation: The command command has been issued. However, the parameter is  
not an attribute that must be updated.  
System Action: Server operation continues.  
User Response: Reissue the command, and specify a compatible set of attributes.  
The HELP UPDATE command may be used to obtain syntax assistance.  
ANR5504E (S/390)  
Command: new attributeconflicts with existing old attribute.  
Explanation: The command command has been issued. However, new attribute  
conflicts with old attribute in updating the device class.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
693  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command, and specify a compatible set of attributes.  
You may have to specify additional keywords to update the device class in a  
compatible manner. The HELP UPDATE command may be used to obtain syntax  
assistance.  
ANR5505E (S/390)  
Command: MOUNTLIMITis less than current number of mounted volumes.  
Explanation: The command command has been issued that specifies a  
MOUNTLIMIT smaller than the existing number of volumes that are already  
allocated.  
System Action: Server operation continues.  
User Response: You may wait until volumes are no longer in use to reissue the  
command. Alternatively, you may cancel sessions or processes that are using  
volumes; then issue DISMOUNT commands to free allocated volumes before  
reissuing the command. The QUERY MOUNT command can be issued to determine  
which volumes are mounted for use by the server.  
ANR5506E (S/390)  
Command: Conflicting parameters parm1and parm2.  
Explanation: The command command has been issued that specifies conflicting  
parameters parm1 and parm2. Conflicting parameters include specifying FORMAT  
and LENGTH with DENSITY, and RETENTION with EXPIRATION.  
System Action: Server operation continues.  
User Response: Reissue the command, and specify a compatible set of parameters.  
The HELP DEFINE or HELP UPDATE commands may be used to obtain syntax  
assistance.  
ANR5507E (S/390)  
Command: Device type devtypenot supported on this platform.  
Explanation: An unsupported device type has been specified for command. In  
MVS, for example, the REEL device type is not supported.  
System Action: Server operation continues.  
User Response: Specify a valid device type for the platform. The HELP DEFINE  
command may be used to obtain syntax assistance.  
694  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5508E (S/390)  
Device class device class not defined in device configuration file.  
Explanation: The issued command requires that the specified device class be  
defined in the device configuration file. The definition was not found.  
System Action: The command is not processed.  
User Response: Reissue the command, and specify a valid device class. You may  
also want to refresh your device configuration file by issuing the BACKUP  
DEVCONFIG command.  
ANR5509E (S/390)  
Command: Parameter Parameter is larger than the allowed maximum of  
Maximum valueM.  
Explanation: The specified parameter is larger than the allowed maximum for this  
device class.  
System Action: The command is not processed.  
User Response: Reissue the command, and specify a parameter less than or equal  
to the allowed maximum.  
ANR5510E (S/390)  
ANR5511E (S/390)  
ANR5512E (S/390)  
Data set name dsn is not valid.  
Explanation: Data set name dsn is not valid.  
System Action: Server operation continues.  
User Response: Reissue the server command, and specify a valid data set name.  
Unit name unit is not valid.  
Explanation: Unit name unit is not valid.  
System Action: Server operation continues.  
User Response: Reissue the server command, and specify a valid unit name.  
Volume serial volser is not valid.  
Explanation: Volume serial volser is not valid.  
System Action: Server operation continues.  
User Response: Reissue the server command, and specify a valid volume serial.  
Tivoli Storage Manager Messages  
695  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5513E (S/390)  
Expiration date expdt is not valid.  
Explanation: Expiration data expdt is not valid.  
System Action: Server operation continues.  
User Response: Reissue the server command, and specify a valid expiration date.  
ANR5514E (S/390)  
Retention period retpd is not valid.  
Explanation: Retention period retpd is not valid.  
System Action: Server operation continues.  
User Response: Reissue the server command, and specify a valid retention period.  
ANR5953W (S/390)  
Unable to generate accounting record - ACCT option not specified in CP  
directory.  
Explanation: The SET ACNT ON command has been entered, but the server is  
unable to generate an accounting record because the ACCT option has not been  
specified in the server’s CP directory entry.  
System Action: Server operation continues. No accounting record is generated.  
User Response: Add the ACCT option to the server’s CP directory entry. To  
suppress these messages until the CP directory can be updated, enter the SET ACNT  
OFF command.  
ANR5954W (S/390)  
Unable to generate accounting record - insufficient memory.  
Explanation: The SET ACNT ON command has been entered, but the server is  
unable to generate an accounting record due to a lack of memory (virtual storage).  
In some cases a 4096-byte buffer is required for accounting operations, and it is this  
buffer that cannot be allocated.  
System Action: Server operation continues. No accounting record is generated.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. Increase the size of the server’s virtual machine. This requires that the default  
storage size be updated in the server’s CP directory entry.  
696  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Reduce the maximum number of client sessions permitted. To do this, edit the  
DSMSERV OPT file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
3. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the DSMSERV OPT file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the DSMSERV OPT file.  
ANR5956E (S/390)  
C library not available, unable to continue.  
Explanation: The C/370 or LE/370 library is not available.  
System Action: Server operation ends.  
User Response: Make the C/370 or LE/370 library available to the server.  
ANR5957W (S/390)  
C library is at level level.  
Explanation: The C run-time library is at a lower level (level) than expected.  
System Action: Server attempts to continue operation.  
User Response: Ensure that the proper level of the C/370 or LE/370 library is  
installed and available to the server.  
ANR5958E (S/390)  
SVM is at level level, the server requires at least required-level, unable to  
continue.  
Explanation: The SVM run-time library is at level level, but the server requires at  
least level required-level.  
System Action: Server operation ends.  
User Response: Check the required PTFs for the server. Ensure that the proper  
level of SVM is installed.  
Tivoli Storage Manager Messages  
697  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5959E (S/390)  
ANR5960E (S/390)  
ANR5961E (S/390)  
Server not running APF authorized. The server and all JOBLIB/STEPLIB  
libraries (C library, etc.) must be authorized.  
Explanation: The server is not running with MVS authorization.  
System Action: Server operation ends.  
User Response: Ensure that all library data sets required by the server are  
authorized.  
Unable to initialize kernel - virtual machine requires ECMODE capability.  
Explanation: The CP directory entry for the server does not contain an OPTION  
ECMODE statement.  
System Action: Server operation ends.  
User Response: Add an OPTION ECMODE statement to the CP directory entry  
for the server.  
Insufficient memory for server initialization.  
Explanation: The server program cannot allocate enough memory (virtual storage)  
to fully initialize itself.  
System Action: Server initialization fails. The server is not started.  
User Response: Allocate additional storage to the server virtual machine or reduce  
the storage required by the server. There are three ways to do this:  
1. Increase the size of the server’s virtual machine. This requires that the default  
storage size be updated in the server’s CP directory entry.  
For MVS, increase the region size; 40M is the recommended minimum size for  
the server but larger servers require more.  
2. Reduce the maximum number of client sessions permitted. To do this, edit the  
DSMSERV OPT file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
3. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the DSMSERV OPT file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4 KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the DSMSERV OPT file.  
698  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5962I (S/390)  
DSMSERV generated at time on date.  
Explanation: The server module has been generated at the indicated date and  
time.  
System Action: Server operation continues.  
User Response: None.  
ANR5963I (S/390)  
Server termination complete.  
Explanation: The server has completed shut down.  
System Action: Server operation ends.  
User Response: None.  
ANR5964E (S/390)  
Server unable to mark itself non-swappable. Return code rc from SYSEVENT  
TRANSWAP.  
Explanation: The server cannot issue a SYSEVENT TRANSWAP macro.  
System Action: Server operation ends.  
User Response: Contact your service representative.  
ANR5965I (S/390)  
Console command: command  
Explanation: A server command command has been received from an MVS  
operator console.  
System Action: Server operation continues.  
User Response: None.  
ANR5967W (S/390)  
Accounting record not produced, return code rc.  
Explanation: There was a problem generating the accounting record.  
System Action: Server operation continues.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
699  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR5980E (S/390)  
Unable to initialize PDM driver - insufficient memory.  
Explanation: The server’s PDM communications driver is unable to initialize itself  
due to insufficient memory (virtual storage).  
System Action: Server initialization fails.  
User Response: Allocate additional storage to the server virtual machine. There  
are three ways to do this:  
1. Increase the size of the REGION parameter on the EXEC or JOB statement of  
the JCL used to start the server.  
2. Reduce the maximum number of client sessions permitted. To do this, edit the  
server options file and reduce the value specified for the MAXSESSIONS  
statement. Note that each client session causes an additional 64KB of memory to  
be allocated.  
3. Decrease the amount of space allocated to the server’s database buffer pool. To  
do this, edit the server options file and reduce the value specified for the  
BUFPOOLSIZE statement. Note that each buffer pool page causes an additional  
4KB of memory to be allocated.  
Note that the server must be shut down (with the HALT command) before changes  
can be made to the server options file.  
ANR5981I (S/390)  
InfoSpeed/PDM communication enabled on port port number.  
Explanation: The server’s PDM communications driver is ready to receive  
connection requests from clients.  
System Action: Server operation continues.  
User Response: None.  
ANR5982E (S/390)  
InfoSpeed accept error rc = rc on port port number.  
Explanation: The server’s InfoSpeed communications driver has received an error  
from the ACCEPT function.  
System Action: Server operation continues and InfoSpeed communications will be  
retried.  
User Response: None.  
700  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6200I  
ANR6201I  
ANR6202I  
ANR6203I  
Command name: Level compression audit level compression audit started as  
process process ID.  
Explanation: A compression audit at the specified level has been started as a  
background server process with the process identifier reported.  
System Action: Server operation continues. The background audit attempts to  
identify client files that may be affected by the client compression problem.  
User Response: None.  
Command name: Level compression audit level compression audit starting as  
background process process ID.  
Explanation: A compression audit at the specified level was started as a  
background server process having the process identifier reported.  
System Action: Server operation continues. The background audit attempts to  
identify client files that may be affected by the client compression problem.  
User Response: None.  
Command name: Verifying candidates from last audit.  
Explanation: A compression audit has started to verify the client file candidates  
that were identified in a previous compression audit execution. The verification  
process eliminates compression candidates that are now found to be expired by  
policy on the server.  
System Action: The audit operation continues.  
User Response: None.  
Command name: Starting level audit level compression audit from qualifying  
entries in the candidates list.  
Explanation: A compression audit is starting to check qualifying candidates from  
the candidates list for the audit level specified. Client files that were identified as  
compression candidates at a lower level will be tested, subject to the qualifications  
that were specified for the command.  
System Action: The audit operation continues.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command. The QUERY PROCESS command can be used to  
monitor the progress of the audit operation.  
Tivoli Storage Manager Messages  
701  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6204I  
Command name: Process process ID, level audit level audit, ended successfully -  
compression suspects = total number of compression suspects.  
Explanation: A compression audit ended and is reporting the total number of  
suspect client files that have been found.  
System Action: The audit operation completes.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command.  
ANR6205I  
Command name: Process process ID, continuing Level 1 compression audit with  
object object ID high order number.object ID low order number.  
Explanation: A level 1 compression audit is starting to evaluate client files for  
signs that they may be affected by the client compression problem. Since a previous  
level 1 audit has been executed, this audit will continue where the last audit stopped  
starting with the object whose identifier is specified.  
System Action: The audit operation continues.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command. The QUERY PROCESS command can be used to  
monitor the progress of the audit operation.  
ANR6206I  
Command name: Process process ID, starting base level 1 compression audit.  
Explanation: A level 1 compression audit is starting to evaluate client files for  
signs that they may be affected by the client compression problem. The audit starts  
with the first client file found on the server, even if previous level 1 audits have  
been executed.  
System Action: The audit operation continues  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command. The QUERY PROCESS command can be used to  
monitor the progress of the audit operation.  
ANR6207I  
Command name: Process process ID, level audit level analysis detected candidate  
file high-level object name low-level object name in file space client filespace name  
for node client node name.  
Explanation: A compression audit has found a candidate file at the audit level  
specified. The name of the client node, file space, and file are displayed. This  
message is issued whenever a candidate file is detected during a compression audit  
that was started with the VERBOSE=YES parameter specified.  
System Action: The audit operation continues.  
702  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command. The QUERY PROCESS command can be used to  
monitor the progress of the audit operation.  
ANR6208I  
Command name: Process process ID, was cancelled - number of candidate files  
candidate files were found in number of files examined files examined prior to  
cancellation.  
Explanation: A compression audit operation was canceled with the CANCEL  
PROCESS command before completion. The number of candidate files that were  
found prior to the cancellation are displayed.  
System Action: The audit operation ends.  
User Response: The compression audit may be restarted with the AUDIT  
COMPRESSION command. The compression candidate list can be displayed with  
the QUERY COMPRESSION command.  
ANR6209I  
Command name: Process process ID, level audit level audit completed  
successfully - number of candidate files candidate files were found in number of  
files examined files examined.  
Explanation: A compression audit operation completed successfully. The number  
of candidate files that were found are displayed.  
System Action: The audit operation ends.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command.  
ANR6210I  
Command name: Process process ID, level audit level audit completed  
successfully - number of candidate files candidate files were found.  
Explanation: A compression audit operation completed successfully. The number  
of candidate files that have been found are displayed.  
System Action: The audit operation ends.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command.  
ANR6211I  
Command name: Process process ID, level audit level analysis detected candidate  
file object name in file space client filespace name for node client node name.  
Explanation: A compression audit has found a candidate file at the audit level  
specified. The name of the client node, file space, and file are displayed. This  
message is issued whenever a candidate file is detected during a compression audit  
that was started with the VERBOSE=YES parameter specified.  
Tivoli Storage Manager Messages  
703  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The audit operation continues.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command. The QUERY PROCESS command can be used to  
monitor the progress of the audit operation.  
ANR6212I  
Command name: Process process ID, level audit level analysis eliminated level  
candidate level candidate file object name in filespace client filespace name for  
node client node name from candidate status.  
Explanation: A compression audit at the level specified has eliminated a candidate  
file through further analysis. The name of the client node, file space, and file are  
displayed. This message is issued whenever a candidate file is eliminated from  
consideration during a compression audit that was started with the VERBOSE=YES  
parameter specified.  
System Action: The audit operation continues.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command. The QUERY PROCESS command can be used to  
monitor the progress of the audit operation.  
ANR6213I  
Command name: Process process ID, was cancelled - number of files promoted  
candidate files were promoted as candidates at level audit level, number of files  
eliminated files were eliminated as candidates, and number of files expired  
candidates were eliminated because they were found to be expired on the  
server.  
Explanation: A compression audit operation was cancelled with the CANCEL  
PROCESS command before completion. The number of candidate files that were  
promoted as candidates at this level of audit, eliminated as candidates at this level  
of audit, and found to be expired before the cancellation are reported.  
System Action: The audit operation ends.  
User Response: The compression audit can be restarted with the AUDIT  
COMPRESSION command. The compression candidate list can be displayed with  
the QUERY COMPRESSION command.  
ANR6214I  
Command name: Process process ID, completed successfully - number of files  
promoted candidate files were promoted as candidates at level audit level,  
number of files eliminated files were eliminated as candidates, and number of files  
expired candidates were eliminated because they were found to be expired on  
the server.  
Explanation: A compression audit operation completed successfully. The number  
of candidate files that were promoted as candidates at this level of audit, eliminated  
as candidates at this level of audit, and found to be expired are reported.  
704  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The audit operation ends.  
User Response: The compression candidate list can be displayed with the QUERY  
COMPRESSION command.  
ANR6215I  
Command name: Backup for file high-level object name low-level object name in  
filespace client filespace name for node client node name could not be forced.  
Explanation: It is not possible to force a backup for the specified file using the  
FORCE BACKUP command. This file was either backed up using an API client or  
by an ADSM version 2 client or higher.  
System Action: The force backup operation continues, the state of the compression  
record for this file is updated.  
User Response: If the file was backed up using a Version 2 client, or higher, you  
may remove this entry as a candidate, using the REMOVE COMPRESSION  
command. If the file was backed up using an API client, notify the client owner to  
again back this file up. Do not remove this entry until it becomes an inactive″  
entry.  
ANR6220I  
ANR6221I  
ANR6222I  
Delete compression operation started as process process ID.  
Explanation: A compression deletion operation was started as a background server  
process with the indicated identifier.  
System Action: Server operation continues.  
User Response: None.  
Force backup operation started as process process ID.  
Explanation: A force backup operation was started as a background server process  
with the indicated identifier.  
System Action: Server operation continues.  
User Response: None.  
Command name: Process process ID was cancelled - number of files files were  
processed prior to cancellation.  
Explanation: The indicated process was cancelled prior to completion. This  
message displays the indicated number of files that were processed before the  
operation was cancelled.  
System Action: The process ends.  
User Response: The operation may be restarted by reissuing the indicated  
command.  
Tivoli Storage Manager Messages  
705  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6223I  
Delete compression process process ID has completed - number of files files were  
deleted.  
Explanation: The indicated process has completed processing. All database  
references have been deleted for the indicated number of files.  
System Action: The process ends.  
User Response: None.  
ANR6224I  
Force backup process process ID has completed - number of files files were  
marked for forced backup.  
Explanation: The indicated process has completed processing. The indicated  
number of files have been marked for forced backup. These files will be backed up  
during the next incremental backup.  
System Action: The process ends.  
User Response: None.  
ANR6225I  
File identifier removed as a suspect for compression errors.  
Explanation: The file with the specified identifier has been removed from the  
database information concerning files with possible compression errors. Other  
database information concerning the file is not affected.  
System Action: Server operation continues.  
User Response: None.  
ANR6226I  
Command name: Started as background process process ID.  
Explanation: A compression cleanup operation has been started to remove  
compression candidate information and temporary database entries from the server  
database. Client files are not affected by this operation.  
System Action: Server operation continues.  
User Response: The CANCEL PROCESS command can be used to cancel the  
compression cleanup operation. The QUERY PROCESS command may be used to  
query the status of the operation.  
ANR6227I  
cleanup process name operation starting as process process ID.  
Explanation: A compression cleanup operation has been started to remove  
compression candidate information and temporary database entries from the server  
database. Client files are not affected by this operation.  
System Action: Server operation continues.  
706  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The CANCEL PROCESS command can be used to cancel the  
compression cleanup operation. The QUERY PROCESS command may be used to  
query the status of the operation.  
ANR6228W  
Cleanup process name: Process process ID has been cancelled - cleanup  
processing is incomplete.  
Explanation: A compression cleanup operation has been cancelled prior to  
successful completion.  
System Action: Server operation continues.  
User Response: The CLEANUP COMPRESSION command can be used to restart  
the cleanup operation.  
ANR6229I  
ANR6300E  
Cleanup process name: Process process ID completed successfully.  
Explanation: A compression cleanup operation has successfully completed.  
System Action: The cleanup process ends.  
User Response: None.  
Command name: Insufficient server memory available for the operation.  
Explanation: A compression testing routine cannot continue because sufficient  
memory is not available on the server.  
System Action: The operation fails.  
User Response: Increase the memory available to the server by increasing the  
server region size, virtual machine size, paging space available on the system, or  
relocating the memory swap file, depending upon the platform on which the server  
is executing. Additional memory may also be made available by limiting server  
activity (sessions, migration, etc.) while this operation is processing.  
ANR6301E  
Command name: Invalid LEVEL specified. This command only supports a value  
of 1 or 2 for the LEVEL parameter.  
Explanation: An invalid LEVEL= parameter has been specified for the command.  
System Action: The command fails.  
User Response: Reissue the command specifying a value of 1 or 2 for the LEVEL  
parameter.  
Tivoli Storage Manager Messages  
707  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6302E  
Command name: Process process ID, failed - number of candidate files candidate  
files were found in number of files examined files examined prior to failure.  
Explanation: A compression audit operation failed before completion. The number  
of candidate files that were found prior to the failure are displayed.  
System Action: The audit operation ends.  
User Response: Examine message that appear before this message on the server  
console or in the activity log to determine the source of the failure. If the error can  
be corrected, re-execute the compression audit. If the failure cannot be determined  
or corrected, contact your service representative. The compression candidate list can  
be displayed with the QUERY COMPRESSION command.  
ANR6303E  
Command name: Process process ID, failed - number of files promoted candidate  
files were promoted as candidates at level audit level, number of files eliminated  
files were eliminated as candidates, and number of files expired candidates were  
eliminated because they were found to be expired on the server.  
Explanation: A compression audit operation failed before completion. The number  
of candidate files that were promoted as candidates at this level of audit, eliminated  
as candidates at this level of audit, and found to be expired before the audit failure  
are reported.  
System Action: The audit operation ends.  
User Response: Examine message that appear before this message on the server  
console or in the activity log to determine the source of the failure. If the error can  
be corrected, re-execute the compression audit. If the failure cannot be determined  
or corrected, contact your service representative. The compression candidate list can  
be displayed with the QUERY COMPRESSION command.  
ANR6304E  
Command name: Command cannot be processed until compression audit is  
performed.  
Explanation: The indicated command cannot be processed until a compression  
audit is performed using the AUDIT COMPRESSION command.  
System Action: The command fails.  
User Response: Issue the AUDIT COMPRESSION command and then repeat the  
attempted operation.  
ANR6305E  
Command name: File identifier is not a suspect for compression errors.  
Explanation: The file with the specified identifier is not listed in the database as a  
suspect for compression errors. The file cannot be removed from the suspect list.  
System Action: Server operation continues.  
708  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the QUERY COMPRESSION command to obtain the correct  
identifier for the file to be removed.  
ANR6306E  
Cleanup process name: Process process ID failed due to server error - cleanup  
processing is incomplete.  
Explanation: A compression cleanup operation has failed before successful  
completion.  
System Action: The cleanup process ends.  
User Response: Examine messages that appear on the server console or in the  
server activity log prior to this message to determine the cause of the error. If the  
error can be identified and corrected, restart the cleanup operation with the  
CLEANUP COMPRESSION command. If the error cannot be corrected, contact  
your service representative.  
ANR6600E  
ANR6601E  
Command: Invalid machine name - machine name.  
Explanation: The machine name specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid machine name.  
Command: Description information exceeds maximum length characters.  
Explanation: The description specified in the command exceeds the maximum  
length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid description.  
ANR6602E  
Command: Recovery instructions file name exceeds maximum length characters.  
Explanation: The recovery instructions file name specified in the command  
exceeds the maximum length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid recovery instructions  
file name.  
ANR6603E  
Command: Characteristics file name exceeds maximum length characters.  
Explanation: The characteristics file name specified in the command exceeds the  
maximum length of allowable characters.  
Tivoli Storage Manager Messages  
709  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid characteristics file  
name.  
ANR6604E  
ANR6605E  
ANR6606E  
ANR6607E  
Command: Invalid building identifier - building.  
Explanation: The building identifier specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid building identifier.  
Command: Invalid floor identifier - floor.  
Explanation: The floor identifier specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid floor identifier.  
Command: Invalid room identifier - room.  
Explanation: The room identifier specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid room identifier.  
Command: Machine machine name is already defined.  
Explanation: The machine specified in the command is already defined to the  
server.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify another machine.  
ANR6608E  
Command: A machine containing a server is already defined.  
Explanation: The ADSMSERVER=YES parameter specified in the command is  
invalid because another machine has already been defined with this parameter. Only  
one machine can be defined to the server as containing a server.  
System Action: The server does not process the command.  
User Response: Issue the command again and do not specify  
ADSMSERVER=YES as a parameter.  
710  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6609I  
ANR6610E  
ANR6611E  
ANR6612I  
ANR6613I  
ANR6614E  
Machine machine name defined.  
Explanation: A DEFINE MACHINE command has added the requested machine  
to the server.  
System Action: None.  
User Response: None.  
Command: Invalid recovery media name - recovery media name.  
Explanation: The recovery media name specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid recovery media  
name.  
Command: Location information exceeds maximum length characters.  
Explanation: The location specified in the command exceeds the maximum length  
of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid location.  
Machine machine name updated.  
Explanation: An UPDATE MACHINE command has updated one or more  
attributes of a machine.  
System Action: None.  
User Response: None.  
Machine machine name deleted.  
Explanation: A DELETE MACHINE command has deleted the requested machine  
from the server.  
System Action: None.  
User Response: None.  
Command: Machine machine name is not defined.  
Explanation: The machine specified in the command is not defined to the server.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
711  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command again and specify a valid machine.  
ANR6615E  
Command: Failed to open input file - file name.  
Explanation: The input file specified in the command cannot be opened by the  
server.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify an input file that is in a file  
system accessible by the server.  
ANR6616E  
ANR6617W  
Command: Invalid sequence number - sequence number.  
Explanation: The sequence number specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid sequence number.  
Command: Node node name cannot be processed because it is not registered.  
Explanation: The node indicated in the message cannot be processed because it is  
not registered.  
System Action: The indicated node is not processed, but another node can be  
processed if specified by this command.  
User Response: Issue the command again and specify a valid registered node.  
ANR6618E  
Command: No matching node registered.  
Explanation: The node specified in the command does not match any node  
registered to the server.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid node.  
ANR6619I  
Node node name associated with machine machine name.  
Explanation: A DEFINE MACHNODEASSOCIATION command has associated  
the specified node with the specified machine. The node node name is associated  
with the machine machine name.  
System Action: None.  
User Response: None.  
712  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6620E  
Command: Machine and node association is already defined.  
Explanation: The machine and node association specified in the command is  
already defined to the server.  
System Action: The server operation continues, but the command has no effect.  
User Response: Issue the command again and specify a valid node.  
ANR6621I  
Node node name disassociated from machine machine name.  
Explanation: A DELETE MACHNODEASSOCIATION command has deleted the  
requested association from the server. The node node name is not associated with  
the machine machine name.  
System Action: None.  
User Response: None.  
ANR6622E  
ANR6623W  
ANR6624E  
Command: Recovery media recovery media name is not defined.  
Explanation: The recovery media specified in the command is not defined to the  
server.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid recovery media.  
Command: Machine machine name cannot be processed because it is not defined.  
Explanation: The machine indicated in the message is not defined to the server.  
System Action: The indicated machine is not processed, but another machine can  
be processed if specified by this command.  
User Response: Issue the command again and specify a valid machine.  
Command: No matching machine defined.  
Explanation: The machine specified in the command does not match any machine  
defined to the server.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid machine.  
Tivoli Storage Manager Messages  
713  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6625I  
Machine machine name associated with recovery media recovery media name.  
Explanation: A DEFINE RECOVERYMEDIAMACHASSOCIATION command  
has associated the specified machine with the specified recovery media. The  
machine machine name is associated with the recovery media recovery media name.  
System Action: None.  
User Response: None.  
ANR6626E  
Command: Recovery media/machine association is already defined.  
Explanation: The recovery media/machine association specified in the command is  
already defined to the server.  
System Action: The server operation continues, but the command has no effect.  
User Response: Issue the command again and specify a valid machine.  
ANR6627I  
Machine machine name disassociated from recovery media recovery media name.  
Explanation: A DELETE RECOVERYMEDIAMACHASSOCIATION command  
has deleted the requested association from the server. Machine machine name is not  
associated with the recovery media recovery media name.  
System Action: None.  
User Response: None.  
ANR6628E  
Command: Volume list exceeds maximum length characters.  
Explanation: The volume list specified in the command exceeds the maximum  
length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid volume list.  
ANR6629E  
Command: Product name exceeds maximum length characters.  
Explanation: The product name specified in the command exceeds the maximum  
length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid product name.  
714  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6630E  
Command: Product information exceeds maximum length characters.  
Explanation: The product information specified in the command exceeds the  
maximum length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify valid product information.  
ANR6631E  
Command: Missing volume list for boot recovery media.  
Explanation: Boot recovery media cannot be defined to the server without  
specifying a volume list.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify the volume list for the boot  
recovery media.  
ANR6632I  
ANR6633I  
ANR6634I  
ANR6635E  
Recovery media recovery media name defined.  
Explanation: A DEFINE RECOVERYMEDIA command has defined the recovery  
media to the server.  
System Action: None.  
User Response: None.  
Recovery media recovery media name updated.  
Explanation: An UPDATE RECOVERYMEDIA command has updated one or  
more attributes of the recovery media.  
System Action: None.  
User Response: None.  
Recovery media recovery media name deleted.  
Explanation: A DELETE RECOVERYMEDIA command has deleted the  
requested recovery media from the server.  
System Action: None.  
User Response: None.  
Command: Recovery media recovery media name is already defined.  
Explanation: The recovery media specified in the command is already defined to  
the server.  
Tivoli Storage Manager Messages  
715  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a different recovery media.  
ANR6636E  
ANR6637E  
ANR6638E  
Command: The characteristics specified for machine machine name exceeds  
maximum length characters.  
Explanation: The characteristics specified in the command exceeds the maximum  
length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify valid characteristics.  
Command: The recovery instructions specified for machine machine name  
exceeds maximum length characters.  
Explanation: The recovery instructions specified in the command exceeds the  
maximum length of allowable characters.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify valid recovery instructions.  
Command: The characteristics for machine machine name are already defined.  
Explanation: The characteristics for the machine specified in the command are  
already defined to the server.  
System Action: The server does not process the command.  
User Response: If the specified machine is defined to the server, issue an  
UPDATE MACHINE command to update the existing characteristics. If the machine  
is not defined to the server, run AUDIT DRM FIX to delete the characteristics.  
ANR6639E  
Command: The recovery instructions for machine machine name are already  
defined.  
Explanation: The recovery instructions for the machine specified in the command  
are already defined to the server.  
System Action: The server does not process the command.  
User Response: If the specified machine is defined to the server, issue an  
UPDATE MACHINE command to update the existing recovery instructions. If the  
machine is not defined to the server, run AUDIT DRM FIX to delete the recovery  
instructions.  
716  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6640E  
Command: Cannot delete volume list for boot recovery media.  
Explanation: A volume list cannot be deleted for boot recovery media. A volume  
list must exist for each boot recovery media defined to the server.  
System Action: The server does not process the command.  
User Response: To delete the volume list, issue an UPDATE RECOVERYMEDIA  
command and specify a recovery media type of OTHER and VOLUMES=″″. To  
change the recovery media type to BOOT, issue an UPDATE RECOVERYMEDIA  
command and specify the volume list containing the boot recovery media and  
TYPE=BOOT.  
ANR6641E  
Command: No association found for machine and node pair specified.  
Explanation: No association found for the machine and node pair specified in the  
command.  
System Action: Server operation continues, but the command has no effect.  
User Response: Issue the command again and specify a valid machine and node  
pair.  
ANR6642E  
Command: No association found for recovery media and machine pair specified.  
Explanation: No association found for the recovery media and machine pair  
specified in the command.  
System Action: Server operation continues, but the command has no effect.  
User Response: Issue the command again and specify a valid recovery media and  
machine pair.  
ANR6643E  
ANR6644E  
Command: Invalid parameter value - parameter value.  
Explanation: The parameter issued in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid parameter.  
Command: A character string must be specified.  
Explanation: The INSERT command is invalid. A character string must be  
specified.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid character string.  
Tivoli Storage Manager Messages  
717  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6645W  
Node node name has already been associated with machine machine name.  
Explanation: The node specified in the DEFINE MACHNODEASSOCIATION  
command is invalid. The node is already associated with another machine shown in  
the message. A node can only be associated with one machine.  
System Action: The indicated node is not processed, but another node can be  
processed if specified by the command.  
User Response: Issue the command again and specify a valid node name.  
ANR6646I  
ANR6647E  
ANR6648I  
Audit command: Auditing disaster recovery manager definitions.  
Explanation: This message is displayed during a database audit and indicates that  
the disaster recovery manager definitions are being examined by the database audit  
process.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: DRM global attributes are missing.  
Explanation: A database audit process finds that the global attributes used for  
server DRM activities are missing.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to recreate the  
DRM global attributes.  
Audit command: DRM global attributes are missing - default values will be used  
to recreate the attributes.  
Explanation: A database audit process finds that the global attributes used for  
server DRM activities are missing. Because FIX=YES has been specified on the  
AUDIT command, default attribute values will be used to recreate the administrative  
global attributes.  
System Action: Audit processing continues.  
User Response: None.  
ANR6649E  
Audit command: DRM machine ID assignments are incorrect.  
Explanation: A database audit process finds that the global attributes machine ID  
used for server DRM activities are incorrect.  
System Action: Audit processing continues.  
718  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the audit command with FIX=YES specified so that the  
DRM global attributes can be corrected.  
ANR6650I  
ANR6651I  
ANR6652I  
Audit command: DRM machine ID Assignments are incorrect - values will be  
corrected.  
Explanation: A database audit process finds that the global attributes machine ID  
used for server DRM activities are incorrect. Since FIX=YES has been specified on  
the AUDIT command, the attribute value will be corrected in the server database.  
System Action: Audit processing continues.  
User Response: None  
Audit command: Invalid priority value encountered for machine machine name.  
Explanation: A database audit process encounters an invalid priority value for the  
machine indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
priority. Or, issue an UPDATE MACHINE command and specify a new priority  
value.  
Audit command: Invalid priority value encountered for machine machine name -  
the default value will be set.  
Explanation: A database audit process encounters an invalid machine priority  
value for the machine indicated. Because FIX=YES has been specified, the audit  
function sets the machine priority value to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue an UPDATE MACHINE  
command to change the value after the audit command has completed.  
ANR6653I  
Audit command: Invalid building value encountered for machine machine name.  
Explanation: A database audit process encounters an invalid building value for the  
machine indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
building value. Or, issue an UPDATE MACHINE command and specify a new  
building value.  
Tivoli Storage Manager Messages  
719  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6654I  
Audit command: Invalid building value encountered for machine machine name -  
the building value will be removed.  
Explanation: A database audit process encounters an invalid building value for the  
machine indicated. Because FIX=YES has been specified, the audit function  
removes the machine building value.  
System Action: Audit processing continues.  
User Response: To set the building value to another value, issue an UPDATE  
MACHINE command after the audit command has completed.  
ANR6655I  
Audit command: Invalid floor value encountered for machine machine name.  
Explanation: A database audit process encounters an invalid floor value for the  
machine indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
floor value. Or, issue an UPDATE MACHINE command and specify a new floor  
value.  
ANR6656I  
Audit command: Invalid floor value encountered for machine machine name - the  
floor value will be removed.  
Explanation: A database audit process encounters an invalid floor value for the  
machine indicated. Because FIX=YES has been specified, the audit function  
removes the machine floor value.  
System Action: Audit processing continues.  
User Response: To set the floor value to another value, issue an UPDATE  
MACHINE command after the audit command has completed.  
ANR6657I  
Audit command: Invalid room value encountered for machine machine name.  
Explanation: A database audit process encounters an invalid room value for the  
machine indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
room value. Or, issue an UPDATE MACHINE command and specify a new room  
value.  
720  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6658I  
Audit command: Invalid room value encountered for machine machine name -  
the room value will be removed.  
Explanation: A database audit process encounters an invalid room value for the  
machine indicated. Because FIX=YES has been specified, the audit function  
removes the machine room value.  
System Action: Audit processing continues.  
User Response: To set the room value for the specified machine to another value,  
use the UPDATE MACHINE command after the audit command has completed.  
ANR6659I  
Audit command: Invalid server value encountered for machine machine name.  
Explanation: A database audit process encounters an invalid server value for the  
machine indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
server value. Or, issue an UPDATE MACHINE command and specify a new server  
value.  
ANR6660I  
Audit command: Invalid server value encountered for machine machine name -  
the default value will be set.  
Explanation: A database audit process encounters an invalid server value for the  
machine indicated. Because FIX=YES has been specified, the audit function sets the  
machine server value to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue an UPDATE MACHINE  
command to change the value after the audit command has completed.  
ANR6661I  
Audit command: Multiple machines are indicated as servers. Only one machine  
should have the server indicator set to YES.  
Explanation: A database audit process encounters more than one machine with the  
server indicator set to YES.  
System Action: Audit processing continues.  
User Response: For a list of machines with the server indicator set to YES, issue  
a QUERY MACHINE ADSMSERVER=YES command. Issue an UPDATE  
MACHINE command for each machine that is not a server.  
Tivoli Storage Manager Messages  
721  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6662I  
ANR6663I  
ANR6664I  
Audit command: Characteristics for machine machine name not found.  
Explanation: A database audit process finds a characteristics reference from a  
machine for characteristics that are not in the server database.  
System Action: Audit processing continues.  
User Response: Issue an UPDATE MACHINE command to load the  
characteristics into the database after the audit command has completed.  
Audit command: Recovery instructions for machine machine name not found.  
Explanation: A database audit process finds a recovery instructions reference from  
a machine for recovery instructions that are not in the server database.  
System Action: Audit processing continues.  
User Response: Issue an UPDATE MACHINE command to load the recovery  
instructions into the database after the audit command has completed.  
Audit command: Invalid access value encountered for recovery media recovery  
media name.  
Explanation: A database audit process encounters an invalid access value for the  
recovery media indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
access value. Or, issue an UPDATE RECOVERYMEDIA command and specify a  
new access value.  
ANR6665I  
Audit command: Invalid access value encountered for recovery media recovery  
media name - the default value will be set.  
Explanation: A database audit process encounters an invalid access value for the  
recovery media indicated. Because FIX=YES has been specified, the audit function  
sets the recovery media access value to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue an UPDATE  
RECOVERYMEDIA command to change the value after the audit command has  
completed.  
722  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6666I  
Audit command: Invalid type value encountered for recovery media recovery  
media name.  
Explanation: A database audit process encounters an invalid type value for the  
recovery media indicated.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
type value. Or, issue an UPDATE RECOVERYMEDIA command and specify a new  
type value.  
ANR6667I  
Audit command: Invalid type value encountered for recovery media recovery  
media name - the default value will be set.  
Explanation: A database audit process encounters an invalid type value for the  
recovery media indicated. Because FIX=YES has been specified, the audit function  
sets the recovery media type value to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue an UPDATE  
RECOVERYMEDIA command to change the value after the audit command has  
completed.  
ANR6668E  
Audit command: Machine is not found for internal machine ID machine ID,  
which is referenced by recovery media.  
Explanation: A database audit process finds recovery media that references a  
machine that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct  
recovery media attributes.  
ANR6669I  
Audit command: Machine is not found for internal machine ID machine ID,  
which is referenced by recovery media - the machine reference will be deleted.  
Explanation: A database audit process finds recovery media that references a  
machine that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
723  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6670E  
Audit command: Recovery media not found for internal recovery media ID  
recovery media ID, which is referenced by a machine.  
Explanation: A database audit process finds a machine that references recovery  
media that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
recovery media attributes.  
ANR6671I  
Audit command: Recovery media not found for internal recovery media ID  
recovery media ID, which is referenced by a machine - the recovery media  
reference will be deleted.  
Explanation: A database audit process finds m machine that references recovery  
media that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be deleted from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
ANR6672E  
Audit command: Client node not found for internal node ID node ID, which is  
referenced by a machine.  
Explanation: A database audit process finds a machine that references a client  
node that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
machine attributes.  
ANR6673I  
Audit command: Client node not found for internal node ID node ID, which is  
referenced by a machine - the client node reference will be deleted.  
Explanation: A database audit process finds a machine that references a client  
node that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
724  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6674E  
Audit command: Machine not found for internal machine ID machine ID, which  
is referenced by a client node.  
Explanation: A database audit process finds a client node that references a  
machine that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
machine attributes.  
ANR6675I  
Audit command: Machine not found for internal machine ID machine ID, which  
is referenced by a client node - the machine reference will be deleted.  
Explanation: A database audit process finds a client node that references a  
machine that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
ANR6676E  
Audit command: Machine not found for internal machine ID machine ID, which  
is referenced by characteristics.  
Explanation: A database audit process finds characteristics that reference a  
machine that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
machine attributes.  
ANR6677I  
Audit command: Machine not found for internal machine ID machine ID, which  
is referenced by characteristics - the machine reference will be deleted.  
Explanation: A database audit process finds characteristics that reference a  
machine that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
725  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6678E  
Audit command: Machine not found for internal machine ID machine ID, which  
is referenced by recovery instructions.  
Explanation: A database audit process finds recovery instructions that reference a  
machine that is not defined in the server database.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
machine attributes.  
ANR6679I  
Audit command: Machine not found for internal machine ID machine ID, which  
is referenced by recovery instructions - the machine reference will be deleted.  
Explanation: A database audit process finds recovery instructions that reference a  
machine that is not defined in the server database. Because FIX=YES has been  
specified for the audit command, the reference will be removed from the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
ANR6680E  
ANR6681I  
ANR6682I  
Audit command: Missing or invalid internal database attribute encountered for  
machine machine name.  
Explanation: A database audit process finds an invalid attribute for the specified  
machine.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
machine attributes.  
Audit command: Missing or invalid internal database attribute encountered for  
machine machine name - the attribute will be corrected.  
Explanation: A database audit process finds an invalid attribute for the specified  
machine. Because FIX=YES has been specified for the audit command the invalid  
attribute will be corrected.  
System Action: Audit processing continues.  
User Response: None.  
Command command ended: number of volumes volumes processed.  
Explanation: The indicated command ended. The total number of volumes  
successfully processed is shown in the message.  
726  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The indicated command ends.  
User Response: None.  
ANR6683I  
Command: Volume volume name was moved from from state state to to state.  
Explanation: Volume volume name is successfully moved from state1 to state2 by  
the indicated command.  
System Action: The indicated volume is moved to the destination state.  
User Response: None.  
ANR6684I  
Command: Volume volume name was deleted.  
Explanation: The MOVE DRMEDIA * WHERESTATE=COURIERRETRIEVE  
command displays the message. Volume volume name is deleted from the server  
database. For database backup volume, after its expiration days have elapsed, the  
volume history record is deleted when it is returned onsite. For an empty scratch  
copy storage pool volume, the volume record is deleted when it is returned onsite.  
System Action: The volume record is deleted from the server database.  
User Response: Issue the CHECKIN LIBVOLUME command for each volume  
returned onsite if the volume is reused by the server.  
ANR6685E  
Command: Volume volume name not defined.  
Explanation: Volume volume name is not defined to the server.  
System Action: The indicated command is not processed if the volume name is  
explicitly specified on the command. If a volume pattern is specified on the  
command, the volume shown is not processed, but the other volumes are processed.  
User Response: Reissue the command specifying a valid volume name.  
ANR6686E  
Command: Volume volume name in use.  
Explanation: The MOVE DRMEDIA * WHERESTATE=MOUNTABLE command  
displays the message. Volume volume name is used for another operation.  
System Action: The command is not processed if the volume is explicitly  
specified on the command. If a volume pattern is specified on the command, the  
indicated volume is not processed, but the other volumes are processed.  
User Response: Wait until the conflicting volume activity has completed, and then  
reissue the command. If the volume is currently mounted, but idle, dismount the  
volume by using a DISMOUNT VOLUME command and then retry this operation.  
Tivoli Storage Manager Messages  
727  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6687E  
Command: Executable command string exceeds maximum length characters.  
Explanation: The length of the executable command string specified with the  
CMD parameter exceeds the maximum length of allowable characters (255).  
System Action: The server stops processing the command.  
User Response: Issue the command again and specify a valid executable command  
with the CMD parameter.  
ANR6690E  
Command: Copy storage pool cstgp name not defined for Offsite Recovery  
Media.  
Explanation: The MOVE DRMEDIA or QUERY DRMEDIA command displays  
the message. The indicated command was issued with a copy storage pool name  
specified, but the specified pool name is not defined to DRM for Offsite Recovery  
Media.  
System Action: The indicated command is not processed.  
User Response: Reissue the command, after defining the specified copy storage  
pool to DRM for Offsite Recovery Media.  
ANR6691E  
Command: No match is found for this move.  
Explanation: The indicated command was issued, but no matching volumes are  
defined to the server or the volume specified is not managed by the command.  
System Action: The command is not processed.  
User Response: Reissue the command specifying the valid volume.  
ANR6694E  
Command: The ORM state state is invalid for a volume with access mode access  
mode.  
Explanation: The indicated command specifies an Offsite Recovery Media state  
that is invalid for a volume with the access mode shown. Specify COURIER or  
COURIERRETRIEVE for a volume that has access mode of OFFSITE.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying COURIER or  
COURIERRETRIEVE as the state for a volume that has access mode of OFFSITE.  
ANR6695E  
Command: Device class device class name not defined for volume volume name.  
Explanation: The MOVE DRMEDIA or QUERY DRMEDIA command displays  
the message. The volume being processed has associated with the device class name  
shown that is not defined to the server.  
728  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The command is not processed if the volume is explicitly  
specified on the command. If a volume pattern is specified on the command, the  
indicated volume is not processed, but the other volumes not associated with the  
indicated class are processed.  
User Response: Reissue the command after the indicated device class is defined to  
the server.  
ANR6696I  
command: operation for volume volume name in library library name starting.  
Explanation: The indicated operation is being started for the volume shown in the  
given library.  
System Action: The server starts the operation in response to the indicated  
command entered by an administrator.  
User Response: For SCSI library users, remove the volume from the slot and issue  
a REPLY command, along with the request ID, to tell the server the volume was  
removed from the library.  
ANR6697I  
ANR6698E  
ANR6699I  
command: operation for volume volume name in library library name completed  
successfully.  
Explanation: The indicated operation has completed successfully for the volume  
shown in the given library.  
System Action: The volume is either deleted from the library inventory (if its  
status is something other than DATA) or marked not present (if its status is DATA).  
User Response: None.  
command: operation for volume volume name in library library name failed.  
Explanation: The indicated operation has failed for the volume shown in the given  
library. This message should be preceded by another error message which provides  
more detail about the error.  
System Action: The volume is not processed.  
User Response: Check for additional message and eliminate the condition that  
caused the failure, then retry the command.  
Cancel in progress.  
Explanation: The MOVE DRMEDIA command has been canceled and will end  
when resources have been freed for the background process. This message may be  
displayed in response to a QUERY PROCESS command for a MOVE DRMEDIA  
command.  
Tivoli Storage Manager Messages  
729  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: None.  
ANR6700I  
ANR6701E  
Command command completed successfully.  
Explanation: The indicated command completed successfully.  
System Action: None.  
User Response: None.  
Command: Invalid courier name - courier name.  
Explanation: The indicated command has been entered with an invalid courier  
name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid courier name.  
ANR6702E  
ANR6703E  
ANR6704E  
Command: Invalid expiration days value - days value.  
Explanation: The indicated command has been entered that specifies an invalid  
expiration days value.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid expiration days value.  
Command: Invalid recovery plan prefix - prefix.  
Explanation: The indicated command has been entered with an invalid recovery  
plan prefix.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid recovery plan prefix.  
Command: Invalid plan instructions prefix - prefix.  
Explanation: The indicated command has been entered with an invalid plan  
instructions prefix.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid plan instructions prefix.  
730  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6705E  
ANR6706E  
ANR6711E  
Command: Invalid character for volume postfix - postfix character.  
Explanation: The indicated command has been entered with an invalid character  
that is to be added to the volumes names in the recovery plan file.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid character.  
Command: Invalid vault name - vault name.  
Explanation: The indicated command has been entered with an invalid vault  
name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid vault name.  
Audit command: An invalid database backup series expiration days encountered.  
Explanation: A database audit process encounters an invalid value for database  
backup series expiration days.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
expiration days. Or, issue an SET DRMDBBACKUPEXPIREDAYS command and  
specify a new expiration days value.  
ANR6712I  
Audit command: An invalid database backup series expiration days encountered  
- the default value will be set.  
Explanation: A database audit process encounters an invalid value for database  
backup series expiration days. Because FIX=YES has been specified, the audit  
function sets the expiration days value to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET  
DRMDBBACKUPEXPIREDAYS command to change the value after the audit  
command has completed.  
ANR6713E  
Audit command: An invalid check label value encountered.  
Explanation: A database audit process encounters an invalid check label value.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
731  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command again and specify FIX=YES to correct the  
check label value. Or, issue a SET DRMCHECKLABEL command and specify a  
new check label value.  
ANR6714I  
Audit command: An invalid check label value encountered - the default value  
will be set.  
Explanation: A database audit process encounters an invalid check label value.  
Because FIX=YES has been specified, the audit function sets the check label value  
to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMCHECKLABEL  
command to change the value after the audit command has completed.  
ANR6715E  
Audit command: An invalid file process value encountered.  
Explanation: A database audit process encounters an invalid file process value.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the file  
process value. Or, issue a SET DRMFILEPROCESS command and specify a new  
file process value.  
ANR6716I  
Audit command: An invalid file process value encountered - the default value  
will be set.  
Explanation: A database audit process encounters an invalid file process value.  
Because FIX=YES has been specified, the audit function sets the file process value  
to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMFILEPROCESS  
command to change the value after the audit command has completed.  
ANR6717E  
Audit command: Extraneous DRM global attribute encountered.  
Explanation: A database audit process finds a nonexistent DRM global attribute.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to delete the  
extraneous attribute.  
732  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6718I  
ANR6719E  
ANR6720I  
Audit command: Extraneous DRM global attribute encountered - the attribute  
will be deleted.  
Explanation: A database audit process finds a nonexistent DRM global attribute.  
Since FIX=YES has been specified, the extraneous attribute will be deleted.  
System Action: Audit processing continues.  
User Response: None.  
Audit command: DRM machine ID assignments not found.  
Explanation: A database audit process finds no entries in server database for  
DRM internal machine ID assignments.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
error.  
Audit command: DRM machine ID assignments not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for  
DRM internal machine ID assignments. Because FIX=YES has been specified for  
the audit command, the audit function creates an entry in the server database for the  
machine ID assignments.  
System Action: Audit processing continues.  
User Response: None.  
ANR6721E  
Audit command: DRM recovery media ID assignments not found.  
Explanation: A database audit process finds no entries in server database for  
DRM internal recovery media ID assignments.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
error.  
ANR6722I  
Audit command: DRM recovery media ID assignments not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for  
DRM internal recovery media ID assignments. Because FIX=YES has been  
specified for the audit command, the audit function creates an entry in the server  
database for the recovery media ID assignments.  
Tivoli Storage Manager Messages  
733  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Audit processing continues.  
User Response: None.  
ANR6723E  
Audit command: Prefix for DRM recovery plan not found.  
Explanation: A database audit process finds no entries in server database for  
DRM recovery plan prefix definitions.  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6724I  
Audit command: Prefix for DRM recovery plan not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for  
DRM recovery plan prefix definitions. Because FIX=YES has been specified for the  
audit command, the audit function creates an entry using the default value in the  
server database for the recovery plan file prefix.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET  
DRMPLANFILEPREFIX command to change the value after the audit command  
has completed.  
ANR6725E  
Audit command: Prefix for DRM recovery plan instructions not found.  
Explanation: A database audit process finds no entries in server database for  
DRM recovery plan instructions prefix definitions.  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6726I  
Audit command: Prefix for DRM recovery plan instructions not found - entry  
will be created.  
Explanation: A database audit process finds no entries in server database for  
DRM recovery plan instructions prefix definitions. Because FIX=YES has been  
specified for the audit command, the audit function creates an entry using the  
default value in the server database for the recovery plan instructions file prefix.  
System Action: Audit processing continues.  
734  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: To override the default value, issue a SET  
DRMPLANINSTRPREFIX command to change the value after the audit command  
has completed.  
ANR6727E  
Audit command: Postfix for DRM replacement volumes names not found.  
Explanation: A database audit process finds no entries in server database for  
DRM postfix definitions for replacement volumes names.  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6728I  
Audit command: Postfix for DRM replacement volumes names not found - entry  
will be created.  
Explanation: A database audit process finds no entries in server database for  
DRM postfix definitions for replacement volumes names. Because FIX=YES has  
been specified for the audit command, the audit function creates an entry using the  
default value in the server database for the replacement volumes postfix.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMPLANVPOSTFIX  
command to change the value after the audit command has completed.  
ANR6729E  
Audit command: Primary storage pools to be restored by DRM not found.  
Explanation: A database audit process finds no entries in server database for  
primary storage pools to be restored by DRM.  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6730I  
Audit command: Primary storage pools to be restored by DRM not found -  
entry will be created.  
Explanation: A database audit process finds no entries in server database for  
primary storage pools to be restored by DRM. Because FIX=YES has been  
specified for the audit command, the audit function creates an entry using the  
default value in the server database for the primary storage pools to be restored by  
DRM.  
System Action: Audit processing continues.  
Tivoli Storage Manager Messages  
735  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: To override the default value, issue a SET DRMPRIMSTGPOOL  
command to change the value after the audit command has completed.  
ANR6731E  
Audit command: Copy storage pools to be managed by DRM not found.  
Explanation: A database audit process finds no entries in server database for copy  
storage pools to be managed by DRM.  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6732I  
Audit command: Copy storage pools to be managed by DRM not found - entry  
will be created.  
Explanation: A database audit process finds no entries in server database for copy  
storage pools to be managed by DRM. Because FIX=YES has been specified for the  
audit command, the audit function creates an entry using the default value in the  
server database for the copy storage pools to be managed by DRM.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMCOPYSTGPOOL  
command to change the value after the audit command has completed.  
ANR6733E  
Command: Cannot complete initialization for process name process.  
Explanation: The indicated process fails during process initialization.  
System Action: The indicated command is ended and server processing continues.  
User Response: This usually indicates that sufficient server memory is not  
available on the server. Allocate additional storage to the server. For details, issue  
HELP MEMORY to display the information online or see “Appendix A. Allocating  
Additional Server Memory”.  
ANR6734E  
Command: Volume volume name not processed: library library name not defined.  
Explanation: The indicated volume is not processed since the designated library  
has not been defined or has been deleted.  
System Action: The volume is not processed.  
User Response: Reissue the command using a different library name, or define the  
library before retrying the command.  
736  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6735E  
Audit command: Courier information for ORM not found.  
Explanation: A database audit process finds no entries in server database for  
courier name definitions used by DRM Offsite Recovery Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6736I  
Audit command: Courier information for ORM not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for  
courier name definitions used by DRM Offsite Recovery Media (ORM). Because  
FIX=YES has been specified for the audit command, the audit function creates an  
entry using the default value in the server database for the courier name definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMCOURIERNAME  
command to change the value after the audit command has completed.  
ANR6737E  
Audit command: Vault name for ORM not found.  
Explanation: A database audit process finds no entries in server database for vault  
name definitions used by DRM Offsite Recovery Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6738I  
Audit command: Vault name for ORM not found - entry will be created.  
Explanation: A database audit process finds no entries in server database for vault  
name definitions used by DRM Offsite Recovery Media (ORM). Because FIX=YES  
has been specified for the audit command, the audit function creates an entry using  
the default value in the server database for the vault name definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMVAULTNAME  
command to change the value after the audit command has completed.  
Tivoli Storage Manager Messages  
737  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6739E  
Audit command: Database backup series expiration days for ORM not found.  
Explanation: A database audit process finds no entries in server database for  
database backup series expiration days definitions used by DRM Offsite Recovery  
Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6740I  
Audit command: Database backup series expiration days for ORM not found -  
entry will be created.  
Explanation: A database audit process finds no entries in server database for  
database backup series expiration days definitions used by DRM Offsite Recovery  
Media (ORM). Because FIX=YES has been specified for the audit command, the  
audit function creates an entry using the default value in the server database for the  
database backup series expiration days definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET  
DRMDBBACKUPEXPIREDAYS command to change the value after the audit  
command has completed.  
ANR6741E  
Audit command: Check label indicator for ORM not found.  
Explanation: A database audit process finds no entries in server database for  
check label definitions used by DRM Offsite Recovery Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6742I  
Audit command: Check label indicator for ORM not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for  
check label definitions used by DRM Offsite Recovery Media (ORM ). Because  
FIX=YES has been specified for the audit command, the audit function creates an  
entry using the default value in the server database for the check label definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMCHECKLABEL  
command to change the value after the audit command has completed.  
738  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6743E  
Audit command: File process indicator for ORM not found.  
Explanation: A database audit process finds no entries in server database for file  
process definitions used by DRM Offsite Recovery Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6744I  
Audit command: File process indicator for ORM not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for file  
process definitions used by DRM Offsite Recovery Media (ORM). Because  
FIX=YES has been specified for the audit command, the audit function creates an  
entry using the default value in the server database for the file process definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMFILEPROCESS  
command to change the value after the audit command has completed.  
ANR6745E  
Audit command: DRM recovery media ID assignments are incorrect.  
Explanation: A database audit process finds that the global attributes recovery  
media id used for server DRM activities are incorrect.  
System Action: Audit processing continues.  
User Response: Reissue the audit command with FIX=YES specified so that the  
DRM global attributes can be corrected.  
ANR6746I  
Audit command: DRM recovery media ID assignments are incorrect - values will  
be corrected.  
Explanation: A database audit process finds that the global attributes recovery  
media ID used for server DRM activities are incorrect. Since FIX=YES has been  
specified on the AUDIT command, the attribute value will be corrected in the server  
database.  
System Action: Audit processing continues.  
User Response: None.  
Tivoli Storage Manager Messages  
739  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6747I  
Number of volumes processed: number  
Explanation: The MOVE DRMEDIA command has processed the number of  
volumes displayed. This message may be displayed in response to a QUERY  
PROCESS command for a MOVE DRMEDIA command.  
System Action: Server operation continues.  
User Response: None.  
ANR6748I  
Number of volumes processed: number. Checking out volume volume name from  
library library name.  
Explanation: The MOVE DRMEDIA command displays the number of volumes  
already processed and the name of the volume currently being checked out from the  
indicated library. This message may be displayed in response to a QUERY  
PROCESS command for a MOVE DRMEDIA command.  
System Action: Server operation continues.  
User Response: None.  
ANR6749I  
Command: process process ID terminated before completion - process canceled.  
Explanation: The indicated background process performing the command shown  
has been canceled.  
System Action: If other processes are executing, these processes continue.  
User Response: None.  
ANR6750E  
Disaster recovery manager operation command being processed is denied -  
server is not in compliance with license terms.  
Explanation: The server refuses a disaster recovery manager operation because the  
current server configuration is not in compliance with the license terms.  
System Action: Server operation continues. Disaster recovery operations cannot be  
performed until the server is licensed for the Tivoli Disaster Recovery Manager  
product.  
User Response: Issue a QUERY LICENSE command to determine which license  
terms are not in compliance.  
ANR6751E  
Disaster recovery manager operation command being processed is denied -  
server is not licensed for disaster recovery manager support.  
Explanation: The server refuses a disaster recovery manager operation because the  
server is not licensed to support the disaster recovery manager.  
740  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues.  
User Response: Obtain the license to support the disaster recovery manager from  
your service provider or reseller. Issue the REGISTER LICENSE command with  
this license to enable the disaster recovery manager support.  
ANR6752W  
Disaster recovery manager operation Command being processed is in violation of  
server license terms - server is not licensed for disaster recovery manager  
support.  
Explanation: The server warns about a disaster recovery manager operation  
because the server is not licensed to support disaster recovery manager.  
System Action: Server operation continues.  
User Response: Obtain the license to support disaster recovery manager from your  
service provider or reseller. Issue the REGISTER LICENSE command with this  
license to enable disaster recovery manager support.  
ANR6753E  
command being processed encountered an internal server error while checking  
license compliance.  
Explanation: The server encountered an internal error in determining whether the  
server is in compliance with license terms.  
System Action: Server operation continues.  
User Response: Issue the QUERY LICENSE and QUERY STATUS commands to  
determine if the server is in compliance with license terms. Start an AUDIT  
LICENSES process to adjust server license information. When this process  
completes, start the session again. If the problem persists, contact your service  
representative.  
ANR6754I  
Machine machine name characteristics deleted.  
Explanation: A DELETE MACHINE command has deleted the requested  
characteristics from the server.  
System Action: None.  
User Response: None.  
ANR6755I  
Machine machine name recovery instructions deleted.  
Explanation: A DELETE MACHINE command has deleted the requested recovery  
instructions from the server.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
741  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6756E  
Machine machine name characteristics not defined to the server.  
Explanation: A DELETE MACHINE command cannot delete the requested  
characteristics from the server. The characteristics for the specified machine are not  
defined to the server.  
System Action: The server operation continues, but the command has no effect.  
User Response: Issue the command again and specify a machine that has  
characteristics defined to the server.  
ANR6757E  
Machine machine name recovery instructions not defined to the server.  
Explanation: A DELETE MACHINE command cannot delete the requested  
recovery instructions from the server. The recovery instructions for the specified  
machine are not defined to the server.  
System Action: The server operation continues, but the command has no effect.  
User Response: Issue the command again and specify a machine that has recovery  
instructions defined to the server.  
ANR6758E  
ANR6759E  
ANR6760E  
Command: Only one character string can be specified.  
Explanation: The INSERT command is invalid. Either a characteristics string can  
be specified or a recovery instructions string can be specified on the command.  
Both types of strings cannot be specified on the command at the same time.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify one valid character string.  
Disaster recovery manager operation command being processed is denied -  
disaster recovery manager support is not available for server platform platform.  
Explanation: The server refuses a disaster recovery manager operation because  
disaster recovery manager support is not available for the indicated server platform.  
System Action: Server operation continues.  
User Response: None.  
Command: Executable command line exceeds maximum length characters for  
volume volume name.  
Explanation: While writing to a command file, one of the following conditions  
occurred:  
742  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The length of the command line written to the command file exceeds the  
LRECL specified for MVS or exceeds the default length for the command line  
written (255).  
The length of the command created after replacing the substitution variables  
&VOL, &VOLDSN, &NL, and &LOC exceeds the server allowable command  
line length (1500).  
System Action: The server stops processing the command.  
User Response: Issue the command again and specify a valid executable command  
with the CMD parameter.  
In the case where volumes are being ejected from the library, it is possible the  
server database does not reflect the true state of the volume. For MOVE  
DRMEDIA, rerun the command after determining the cause of the error. For MOVE  
MEDIA, an update volume command should be issued setting the access of the  
volume to read only.  
If this message is issued by a MOVE or QUERY DRMEDIA command and the  
volume record has been deleted from the server database, you can not use the  
MOVE or QUERY DRMEDIA commands to create the command file entry for this  
volume. In this case, you must manually issue the proper command.  
ANR6761E  
Command: WHERESTATE parameter is required.  
Explanation: The indicated command specifies a volume name containing a  
pattern matching character and the TOSTATE parameter. The WHERESTATE  
parameter is not specified. The specification is invalid. Pattern-matching for volume  
names is only allowed when the WHERESTATE parameter is specified.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a specific volume name or by  
specifying the WHERESTATE parameter along with the TOSTATE parameter.  
ANR6762E  
Command: The specified destination state tostate is invalid for volume volume  
name in current state state.  
Explanation: The indicated command specifies a destination state that is invalid  
for the volume name shown in the indicated current state.  
System Action: The server does not process the volume.  
User Response: Issue the command again and specify a valid destination state for  
the volume name shown.  
Tivoli Storage Manager Messages  
743  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6763I  
Command: The specified command has been written to file ’file name’.  
Explanation: The command string specified with the CMD parameter on the  
command shown is written to the indicated file for each volume successfully  
processed.  
System Action: None  
User Response: Execute the commands written to the file.  
ANR6764E  
ANR6765E  
ANR6766E  
command: Command file name exceeds maximum characters characters.  
Explanation: The file name specified for containing the executable commands  
generated by DRM exceeds the maximum valid length shown.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a valid file name.  
Command: Invalid not mountable location name - not mountable name.  
Explanation: The indicated command has been entered with an invalid not  
mountable location name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid not mountable location name.  
Command: No command string is specified for FORMAT=CMD.  
Explanation: The indicated command has been entered with a FORMAT=CMD to  
write a command string to a file, but no command string is specified.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a command string to be written  
to a file.  
ANR6767E  
Command: Invalid command file name - command file name.  
Explanation: The indicated command has been entered with an invalid command  
file name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid command file name.  
744  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6768E  
ANR6769E  
ANR6770I  
command: Prefix exceeds maximum characters characters.  
Explanation: The prefix specified for recovery plan files or for plan instructions  
files exceeds the maximum valid length. The maximum valid length is shown in the  
message.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a valid prefix.  
Audit command: Not mountable name information for ORM not found.  
Explanation: A database audit process finds no entries in server database for not  
mountable location name definitions used by DRM Offsite Recovery Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
Audit command: Not mountable name information for ORM not found - entry  
will be created.  
Explanation: A database audit process finds no entries in server database for not  
mountable location name definitions used by DRM Offsite Recovery Media (ORM).  
Because FIX=YES has been specified for the audit command, the audit function  
creates an entry using the default value in the server database for the courier name  
definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET  
DRMNOTMOUNTABLENAME command to change the value after the audit  
command has completed.  
ANR6771E  
Audit command: Command file name information for ORM not found.  
Explanation: A database audit process finds no entries in server database for  
command file name definitions used by DRM Offsite Recovery Media (ORM).  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
Tivoli Storage Manager Messages  
745  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6772I  
Audit command: Command file name information for ORM not found - entry  
will be created.  
Explanation: A database audit process finds no entries in server database for  
command file name definitions used by DRM Offsite Recovery Media (ORM).  
Because FIX=YES has been specified for the audit command, the audit function  
creates an entry using the default value in the server database for the command file  
name definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET DRMCMDFILENAME  
command to change the value after the audit command has completed.  
ANR6773E  
Command: Unable to open file ’command file name’ for output.  
Explanation: An error occurred while opening the command file name shown. The  
file name shown in the message is specified with the indicated command, the SET  
command, or the default name generated by the indicated command.  
System Action: The server does not process the indicated command.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated. In AIX, make sure that the file name  
specified in the command or in the SET command is a full path file name, not a  
directory path name. In MVS, make sure that the file name specified in the  
command or in the SET command is a valid MVS file name. Reissue the command  
after determining the cause of the error.  
ANR6774E  
Command: Invalid volume transition states - from ’specified WHERESTATE’  
state to ’specified TOSTATE’ state.  
Explanation: The TOSTATE specified is an invalid destination state for the  
WHERESTATE specified.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid destination state.  
ANR6775E  
Command: Error writing to file ’file name’ for volume volume name.  
Explanation: An error occurred while writing to the file name shown for the  
indicated volume.  
System Action: The server stops processing the command.  
746  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated. Reissue the command after  
determining the cause of the error.  
In the case where volumes are being ejected from the library, it is possible the  
server database does not reflect the true state of the volume. For MOVE  
DRMEDIA, rerun the command after determining the cause of the error. For MOVE  
MEDIA, an update volume command should be issued setting the access of the  
volume to read only.  
If this message is issued by a MOVE or QUERY DRMEDIA command and the  
volume record has been deleted from the server database, you can not use the  
MOVE or QUERY DRMEDIA commands to create the command file entry for this  
volume. In this case, you must manually issue the proper command.  
ANR6776E  
Command: Could not delete file: file name  
Explanation: The indicated command failed but the file created could not be  
deleted.  
System Action: None.  
User Response: Delete the file shown.  
ANR6777E  
Command: Command file ’file name’ already in use.  
Explanation: The command indicated references a command file name that is in  
use. The command file name shown is selected for use by the server in the  
following order:  
The file name specified on the indicated command.  
The file name specified on the SET command.  
The file name generated by the server (AIX only).  
System Action: The server does not process the command.  
User Response: Reissue the command at a later time or reissue the command  
specifying a different command file name.  
ANR6778E  
Command: Volume volume name not processed: device type device type not  
supported.  
Explanation: The indicated volume is not processed because the device type  
shown is not supported by the function.  
System Action: The indicated volume is not processed.  
User Response: None.  
Tivoli Storage Manager Messages  
747  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6779E  
Disaster recovery manager operation command being processed is denied -  
disaster recovery manager support is not available for server platform.  
Explanation: The server refuses a disaster recovery manager operation because  
disaster recovery manager support is not available for the server platform.  
System Action: Server operation continues.  
User Response: None.  
ANR6780E  
Audit command: An invalid recovery plan file expiration days encountered.  
Explanation: A database audit process encounters an invalid value for recovery  
plan file expiration days.  
System Action: Audit processing continues.  
User Response: Issue the command again and specify FIX=YES to correct the  
expiration days. Or, issue an SET DRMRPFEXPIREDAYS command and specify a  
new expiration days value.  
ANR6781I  
Audit command: An invalid recovery plan file expiration days encountered - the  
default value will be set.  
Explanation: A database audit process encounters an invalid value for recovery  
plan file expiration days. Because FIX=YES has been specified, the audit function  
sets the expiration days value to the default value.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET  
DRMRPFEXPIREDAYS command to change the value after the audit command has  
completed.  
ANR6782E  
Audit command: Recovery plan file expiration days not found.  
Explanation: A database audit process finds no entries in server database for  
recovery plan file expiration days definitions.  
System Action: Audit processing continues.  
User Response: Issue the audit command again and specify FIX=YES to correct  
the error.  
ANR6783I  
Audit command: Recovery plan file expiration days not found - entry will be  
created.  
Explanation: A database audit process finds no entries in server database for  
recovery plan file expiration days definitions. Because FIX=YES has been specified  
748  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
for the audit command, the audit function creates an entry using the default value in  
the server database for the recovery plan file expiration days definitions.  
System Action: Audit processing continues.  
User Response: To override the default value, issue a SET  
DRMRPFEXPIREDAYS command to change the value after the audit command has  
completed.  
ANR6784I  
Number of volumes processed: number volumes processed. Volumes sent to  
library library name for checkout: number volumes sent.  
Explanation: The MOVE DRMEDIA command has processed the number of  
volumes shown. Currently, the MOVE DRMEDIA command has sent for processing  
the number of volumes shown to the library shown. This message may be displayed  
in response to a QUERY PROCESS command for a MOVE DRMEDIA command.  
System Action: Server operation continues.  
User Response: None.  
ANR6785W  
Warning: The ADSM V3 Disaster Recovery Manager Disk Image Dump  
function is not supported in the Tivoli Disaster Recovery Manager. The ADSM  
V3 DRM Disk Image Restore function has been stabilized with no new  
maintenance or hardware support planned.  
Explanation: None.  
System Action: DRM Disk Image Dump and Restore function continues.  
User Response: None.  
ANR6900I  
ANR6901I  
Command: The recovery plan file file name was created.  
Explanation: The recovery plan file was created.  
System Action: None.  
User Response: None.  
Number of plan stanzas processed: number.  
Explanation: The PREPARE command has processed the number of stanzas  
displayed. This message may be displayed in response to a QUERY PROCESS  
command for a PREPARE command.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
749  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6902I  
Number of plan stanzas processed: number. Currently processing stanza:  
recovery plan stanza name.  
Explanation: The PREPARE command displays the number of stanzas already  
processed and the name of the stanza currently being processed. This message may  
be displayed in response to a QUERY PROCESS command for a PREPARE  
command.  
System Action: Server operation continues.  
User Response: None.  
ANR6903I  
Cancel in progress.  
Explanation: The PREPARE command has been canceled and will end when  
resources have been freed for the background process. This message may be  
displayed in response to a QUERY PROCESS command for a PREPARE command.  
System Action: Server operation continues.  
User Response: None.  
ANR6904I  
Sending recovery plan file to target server.  
Explanation: The PREPARE command is sending the recovery plan file to the  
target server. This message may be displayed in response to a QUERY PROCESS  
command for a PREPARE command.  
System Action: Server operation continues.  
User Response: None.  
ANR6905I  
Command: Recovery plan file RPF volume name was created. Specified device  
class device class name.  
Explanation: The recovery plan file was created on the target server.  
System Action: Server operation continues.  
User Response: None.  
ANR6912W  
Command: The database was not backed up.  
Explanation: No backups have been made of the server data base.  
System Action: Stanzas in the recovery plan do not include database recovery  
information.  
User Response: Backup the server data base by issuing the BACKUP DB  
command.  
750  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6913W  
Command: No volumes with backup data exist in copy storage pool storage pool  
name.  
Explanation: A copy storage pool does not contain any volumes with usable data.  
System Action: Stanzas in the recovery plan do not include recovery information  
for any volumes in the storage pool.  
User Response: Determine why this storage pool has no volumes with usable data.  
ANR6915W  
Command: Storage pool storage pool name storage pool type is not defined to the  
server.  
Explanation: A storage pool that is not defined to the server was specified by SET  
DRMPRIMSTGPOOL, SET DRMCOPYSTGPOOL, or on the PREPARE command  
line.  
System Action: Stanzas in the recovery plan do not include recovery information  
for the storage pool.  
User Response: Correct the storage pool specification or define the storage pool to  
the server.  
ANR6916W  
ANR6918W  
Command: No copy storage pools are defined.  
Explanation: The server has no copy storage pools defined.  
System Action: Recovery plan file will not contain copy storage pool information.  
User Response: Define copy storage pools in the server.  
Command: Recovery instructions file file name not found.  
Explanation: A source file for recovery instructions was not found.  
System Action: The recovery plan will not contain recovery instructions.  
User Response: To get recovery instructions in the recovery plan, ensure the  
corresponding instructions source file exists. If it does, check authorizations to the  
file.  
ANR6920W  
Command: Generated replacement volume name volume name is not valid for  
server device type device type. Original volume name: volume name. Stanza is  
stanza name.  
Explanation: Appending the replacement volume name postfix (as defined with  
SET DRMPLANVPOSTFIX) to the original volume name has created a name that  
is not valid for the server device type shown.  
System Action: Replacement volume name is used in the recovery plan stanza.  
Tivoli Storage Manager Messages  
751  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Devise a naming convention that allows the use of the  
replacement volume name postfix or at restore time manually update the generated  
recovery plan with a legal replacement name. For additional information and related  
commands, refer to the Administrator’s Reference for your particular platform.  
ANR6921W  
Command: Cannot locate server options file ’file name’.  
Explanation: The Prepare command cannot open the specified server options file.  
System Action: VOLHISTORY and DEVCONFIG options are added to the  
recovery plan file stanza DSMSERV.OPT.FILE.  
User Response: None.  
ANR6922W  
Command: No machine information was defined for the machine that contains  
server server name.  
Explanation: The machine information has not been saved in the server data base.  
System Action: The recovery plan file does not contain the machine and recovery  
media information stanzas.  
User Response: If you want to include the machine information in the recovery  
plan file, issue the DEFINE MACHINE command to save the machine information  
in the server data base and reissue the PREPARE command.  
ANR6923W  
Command: No recovery media defined for machine machine name.  
Explanation: No recovery media has been defined to the server for the specified  
machine.  
System Action: The recovery plan file does not contain the machine recovery  
media stanza.  
User Response: If you want to include the machine recovery media information in  
the recovery plan file, issue the DEFINE RECOVERYMEDIA command. Reissue  
the PREPARE command after the appropriate commands have been issued to define  
the recovery media. For additional information and related commands, refer to the  
Administrator’s Reference for your particular platform.  
ANR6924W  
Command: No recovery instructions defined for machine machine name.  
Explanation: No recovery instructions have been defined to the server for the  
specified machine.  
System Action: The recovery plan file does not contain the machine recovery  
instructions stanza.  
752  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If you want to include the machine recovery instructions in the  
recovery plan file, issue the INSERT command. Reissue the PREPARE command  
after the appropriate commands have been issued to define the recovery media. For  
additional information and related commands, refer to the Administrator’s Reference  
for your particular platform.  
ANR6925W  
Command: No machine characteristics defined for machine machine name.  
Explanation: No characteristics have been defined to the server for the specified  
machine.  
System Action: The recovery plan file does not contain the machine characteristics  
stanza.  
User Response: If you want to include the machine recovery instructions in the  
recovery plan file, issue the INSERT command. Reissue the PREPARE command  
after the appropriate commands have been issued to define the recovery media. For  
additional information and related commands, refer to the Administrator’s Reference  
for your particular platform.  
ANR6926W  
Command: There is at least one invalid generated volume name associated with  
storage pool storage pool server device type device type in stanza stanza name.  
Explanation: Appending the replacement volume name postfix (as defined with  
SET DRMPLANVPOSTFIX) to the original volume name has created a name that  
is not valid for the server device type shown.  
System Action: Replacement volume name is used in the recovery plan stanza.  
User Response: Devise a naming convention that allows the use of the  
replacement volume name postfix or at restore time manually update the generated  
recovery plan with a legal replacement name. For additional information and related  
commands, refer to the Administrator’s Reference for your particular platform.  
ANR6937E  
command: parameter name parameter not allowed from the command line.  
Explanation: The parameter shown is not allowed from the command line  
interface.  
System Action: The server does not process the command.  
User Response: Reissue the command with the parameter from the web.  
ANR6938I  
No information found for stanza stanza name.  
Explanation: No information found for recovery plan file stanza shown.  
System Action: The server does not display the information for the stanza.  
Tivoli Storage Manager Messages  
753  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None  
ANR6939E  
Command: Invalid recovery plan file stanza name - stanza name.  
Explanation: The specified recovery plan file stanza name is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid recovery plan file  
stanza name.  
ANR6940E  
command command not allowed from server console.  
Explanation: The indicated command is not allowed to be issued from the server  
console.  
System Action: The command is not executed.  
User Response: Reissue the command from an administrator using an  
Administrative Client.  
ANR6941E  
ANR6942E  
ANR6943E  
Query recovery plan file content is waiting for mount point in device class  
device class name.  
Explanation: Query recovery plan file content has begun to wait for a mount point  
that can be used for a volume in the device class shown.  
System Action: The function waits for the mount point.  
User Response: Respond to any mount requests.  
Query recovery plan file content is waiting for access to input volume volume  
name.  
Explanation: Query recovery plan file content has begun to wait for availability of  
the input volume shown.  
System Action: The function waits for the volume to become available.  
User Response: None.  
Query recovery plan file content is waiting for mount of input volume volume  
name.  
Explanation: Query recovery plan file content has begun to wait for the mount of  
the input volume shown.  
System Action: The function waits for mount.  
User Response: Respond to any mount requests.  
754  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6944E  
Command: Invalid recovery plan file name - recovery plan file name.  
Explanation: The recovery plan file name specified in the command is invalid.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid recovery plan file  
name.  
ANR6945E  
Command: Cannot find filespace filespace name for recovery plan file recovery  
plan file name.  
Explanation: The server cannot find the filespace (ADSM.SERVER) for recovery  
plan file specified in the server.  
System Action: The retrieve operation ends, and the server operation continues.  
User Response: Issue QUERY FILESPACE command on the target server to see if  
there is any filespaces created for the recovery plan file. The filespace name for the  
recovery plan file is ADSM.SERVER.  
ANR6946E  
Command: Retrieve failed for recovery plan file name - error on input storage  
device.  
Explanation: The server ends an retrieve operation because an I/O error has been  
encountered by the server in reading from a device.  
System Action: The retrieve operation ends, and the server operation continues.  
User Response: Query the activity log to find messages preceding this one that  
specify the device that is failing. The server may need to be shut down with the  
HALT command to correct the hardware problem.  
ANR6947E  
Command: Data storage retrieve failed for recovery plan file name - data  
integrity error detected.  
Explanation: The server ends the retrieve operation because an internal database  
integrity error has been encountered on the server.  
System Action: The retrieve operation ends, and the server operation continues.  
User Response: Contact your service representative.  
ANR6948E  
Command: Cannot find the recovery plan file for Recovery plan file name.  
Explanation: The server cannot find the specified recovery plan file.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
755  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue the command again and specify a valid recovery plan file  
name. Use the QUERY RPFILE command to view the name of the recovery plan  
file that you are interested in displaying its content.  
ANR6949E  
Command: No matching device class defined.  
Explanation: The device class specified in the command does not match any  
device class defined to the server.  
System Action: The server does not process the command.  
User Response: Issue the command again and specify a valid device class.  
ANR6950E  
Command: The recovery plan file was not created.  
Explanation: Due to a processing error, a recovery plan file was not created.  
System Action: Recovery plan file not created.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Reissue the command, after  
determining the cause of the error.  
ANR6951E  
Command: Recovery plan file file name was not created.  
Explanation: Due to a processing error, a recovery plan file was not created.  
System Action: Recovery plan file not created.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated and that there is sufficient space in the  
file system for the file. Reissue the command, after determining the cause of the  
error.  
ANR6952E  
Command: File name file name already exists.  
Explanation: File already exits.  
System Action: None.  
User Response: Determine why file already exists. If possible, delete it. Reissue  
the command, after determining the cause of the error.  
ANR6953E  
Command: File write error.  
Explanation: An error occurred while writing to the recovery plan file.  
System Action: The recovery plan file was not created.  
756  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that there is sufficient  
space in the file system for the file. Reissue the command after determining the  
cause of the error.  
ANR6954E  
Command: Unable to open file ’file name’ for output.  
Explanation: An error occurred while opening the recovery plan file for output.  
System Action: The recovery plan file was not created.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Make sure that the server has  
proper authority to write to the file indicated. Reissue the command after  
determining the cause of the error.  
ANR6959E  
ANR6960E  
ANR6962E  
Command: Plan instructions prefix ’instructions prefix’ is not valid.  
Explanation: The prefix specified for recovery instructions is not valid.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix.  
Command: Recovery plan prefix ’plan prefix’ is not valid.  
Explanation: The prefix specified for the recovery plan file is too long.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix.  
Command: Query database failed.  
Explanation: A server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
ANR6963E  
Command: Query log failed.  
Explanation: A server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
Tivoli Storage Manager Messages  
757  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
ANR6964E  
ANR6965E  
ANR6966E  
ANR6967E  
Command: Query storage pool failed.  
Explanation: An server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
Command: Query volume failed.  
Explanation: An server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
Command: Query database volume failed.  
Explanation: A server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
Command: Query log volume failed.  
Explanation: A server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
758  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6968E  
ANR6969E  
ANR6970E  
Command: Query volume history failed.  
Explanation: An server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
Command: Query device class failed.  
Explanation: An server database query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
Command: A recovery plan file is already being created.  
Explanation: The server command processor will not start a background process  
to execute another PREPARE command.  
System Action: The command process ends and server operation continues.  
User Response: Reissue the command after the first PREPARE command has  
completed.  
ANR6971E  
Command: Could not delete plan file plan file name.  
Explanation: Prepare command failed but the plan file created could not be  
deleted.  
System Action: None.  
User Response: Delete the plan file.  
ANR6972E  
Command: Query machine failed.  
Explanation: A server machine query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
Tivoli Storage Manager Messages  
759  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
ANR6973E  
ANR6974E  
ANR6975E  
ANR6976E  
Command: Query recovery media failed.  
Explanation: A server recovery media query error occurred. This message always  
accompanies another error message and provides more detail about that error.  
System Action: The recovery plan file was not created.  
User Response: Issue a QUERY ACTLOG command to view the activity log and  
search for messages. If the error cannot be isolated and resolved, contact your  
service representative.  
Command: Unable to open file file name.  
Explanation: An error occurred while PREPARE was attempting to open the local  
recovery plan file copy in order to send it to the target server.  
System Action: The recovery plan file is not stored on the target server.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Reissue the command after  
determining the cause of the error.  
Command: Unable to read file file name.  
Explanation: An error occurred while PREPARE was attempting to read the local  
recovery plan file copy in order to send it to the target server.  
System Action: The recovery plan file is not stored on the target server.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Reissue the command after  
determining the cause of the error.  
Command: The recovery plan file was not stored on another server and the  
local copy file name cannot be deleted.  
Explanation: Due to a processing error, a recovery plan file was not stored on  
target server and the local copy of the plan file cannot be deleted.  
System Action: PREPARE processing ends.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. After determining the cause of  
the error, re-issue the PREPARE command and delete the local recovery plan file.  
760  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6977E  
Command: Device class name device class name exceeds maximum characters  
characters.  
Explanation: The command shown has been entered and specifies a device class  
name that is too long. The maximum valid length for a device class name is shown  
in the message.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a valid device class name.  
ANR6978E  
Command: Invalid device class device class name.  
Explanation: The specified device class cannot be used by the command shown.  
Possible reasons include:  
The device class is not defined.  
The device class is defined but not of type SERVER.  
The name specified is an invalid device class name.  
System Action: The server does not process the command.  
User Response: Reissue the command with a valid device class.  
ANR6979E  
Command: Recovery plan file was not created. Specified device class device class  
name.  
Explanation: A recovery plan file cannot be not created using the specified device  
class.  
System Action: Recovery plan file not created.  
User Response: Examine error messages that may have been displayed prior to  
this message and correct any problems, if possible. Reissue the command, after  
determining the cause of the error.  
ANR6980E  
Command: Prefix prefix exceeds maximum characters characters.  
Explanation: The command shown has been entered and specifies a plan or  
instructions prefix that is too long. The maximum valid length is shown in the  
message.  
System Action: The server does not process the command.  
User Response: Reissue the command specifying a shorter prefix.  
Tivoli Storage Manager Messages  
761  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR6984E  
Command: Out of space on sequential media, scratch media could not be  
mounted. Specified device class device class name; maximum capacity: number  
of bytes bytes.  
Explanation: During command PREPARE processing, the process encounters an  
out-of-space condition writing to the sequential media. Command PREPARE ends  
when there is no more space on the sequential media for storing data.  
System Action: Command PREPARE processing ends. Server processing  
continues.  
User Response: Increase the device class maximum capacity and reissue the  
PREPARE command. If an object was created on the target server, issue the  
RECONCILE VOLUMES FIX=YES to delete the object from the target server.  
ANR6985E  
Command: Error encountered in accessing data storage - volume already in use.  
Explanation: During command command processing, a volume cannot be used  
because it is already defined in a storage pool, or has been previously used by an  
export, database dump, database backup, or DRM prepare operation or is in use by  
another process.  
System Action: The command command operation is ended and server operation  
continues.  
User Response: Re-issue the PREPARE command.  
ANR6986E  
Command: The DELETELATEST parameter is only valid for volume history  
types RPFILE or RPFSNAPSHOT.  
Explanation: The command failed because an invalid volume history type was  
specified for the TYPE= parameter.  
System Action: The command fails, and server operation continues.  
User Response: Re-issue the command and specify a valid type value.  
ANR7800I (AIX) DSMSERV generated at time on date.  
Explanation: The server module was generated at the indicated date and time.  
System Action: Server operation continues.  
User Response: None.  
762  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7800I (AS/400)  
QANRSERV generated at time on date.  
Explanation: The ADSM server module has been generated at the indicated date  
and time.  
System Action: Server operation continues.  
User Response: None.  
ANR7800I (HP-UX)  
DSMSERV generated at time on date.  
Explanation: The server module was generated at the indicated date and time.  
System Action: Server operation continues.  
User Response: None.  
ANR7800I (Solaris)  
DSMSERV generated at time on date.  
Explanation: The server module was generated at the indicated date and time.  
System Action: Server operation continues.  
User Response: None.  
ANR7800I (Windows NT)  
DSMSERV generated at time on date.  
Explanation: The server module was generated at the indicated date and time.  
System Action: Server operation continues.  
User Response: None.  
ANR7801I (AIX) Subsystem (master) PID is process identifier.  
Explanation: The server kernel extension process has the indicated process  
identifier.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
763  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7801I (HP-UX)  
Subsystem (master) process ID is process identifier.  
Explanation: The server’s master HP-UX process has the indicated process  
identifier.  
System Action: Server operation continues.  
User Response: None.  
ANR7801I (Solaris)  
Subsystem process ID is process identifier.  
Explanation: The server process has the indicated process identifier.  
System Action: Server operation continues.  
User Response: None.  
ANR7802E (AIX) Shared memory segments for a server running in the current directory already  
exist. The -F parameter can be used to overwrite.  
Explanation: Shared memory segments are created for each instance of the server  
based on the current directory. This message indicates that the shared memory  
segments already exist. A server is presently running from the current directory or a  
server running from the current directory ended abnormally.  
System Action: The server terminates.  
User Response: If the server running in the current directory terminated  
abnormally, start dsmserv with the -F parameter to force the existing shared memory  
segments to be overwritten. If you want to run multiple instances of the server, each  
instance must be run from a separate directory with a separate dsmserv.dsk file and  
have separate log, database, and storage volumes.  
ANR7803E (AIX) Attempt to overwrite a shared memory segment, as directed with the -F  
parameter, FAILED.  
Explanation: The server has been started with the -F parameter and unsuccessfully  
attempted to overwrite existing shared memory segments. This error occurs when  
the user that starts the server with -F parameter is not the owner of the shared  
memory segments and lacks the required authority.  
System Action: Server terminates.  
User Response: Resolve the authorization problem and restart the server.  
764  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7804I (AIX) An server is already running from this directory.  
Explanation: The server has attempted to open the adsmserv.lock file in the  
current directory but failed to do so because an existing server already has the file  
open.  
System Action: Server terminates.  
User Response: Examine the contents of the adsmserv.lock file. The process ID  
for the server that is running is recorded in this file. Two servers cannot be started  
from the same directory. You may remove the adsmserv.lock file and attempt to start  
the server ONLY if the recorded process ID is NOT currently running dsmserv. The  
'ps -e' AIX command can be used to display processes that are currently running.  
ANR7804I (HP-UX)  
A server is already running from this directory.  
Explanation: The server has attempted to open the adsmserv.lock file in the  
current directory but failed to do so because an existing server already has the file  
open.  
System Action: Server terminates.  
User Response: Examine the contents of the adsmserv.lock file. The process ID  
for the server that is running is recorded in this file. Two servers cannot be started  
from the same directory. You may remove the adsmserv.lock file and attempt to start  
the server ONLY if the recorded process ID is NOT currently running dsmserv. The  
'ps -e' command can be used to display processes that are currently running.  
ANR7805E (AIX) Volume volume name is in use by another server.  
Explanation: The server has attempted to open a disk volume but has discovered  
that the volume is in use by another server.  
System Action: The open operation fails for the volume.  
User Response: To prevent concurrent RAW volume access by more than one  
server, files are created in the /tmp directory to 'lock' these volumes. The names of  
these temporary files are /tmp/adsm.disk.dev.<volumename> where <volumename>  
is the name of the RAW volume defined in the /dev directory. Please note that the  
name for the logical volume as defined in SMIT is represented in the /dev directory  
with a leading 'r' character (for example, a raw volume defined in SMIT as dsmstg1  
will be represented in the /dev directory as the file /dev/rdsmstg1).  
You may use the AIX 'ps -e' command to determine if other dsmserv processes are  
running. You may remove the temporary lock files and attempt to re-start the server  
ONLY if there are no other dsmserv processes running  
Tivoli Storage Manager Messages  
765  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7805E (Solaris)  
Volume volume name is in use by another server.  
Explanation: The server has attempted to open a disk volume but has discovered  
that the volume is in use by another server.  
System Action: The open operation fails for the volume.  
User Response: To prevent concurrent RAW volume access by more than one  
server, files are created in the /tmp directory to 'lock' these volumes. The names of  
these temporary files are /tmp/adsm.disk.dev.<volumename> where <volumename>  
is the name of the RAW volume defined in the /dev directory. Please note that the  
name for a RAW logical volume as defined in Solaris is in the /dev directory with a  
leading 'r' character (for example, a raw volume defined in Solaris on a regular  
SCSI drive as dsk/c0t0d0s0 will be represented in the /dev directory as the file  
/dev/rdsk/c0t0d0s0). For a REGULAR DISK volume, the server automatically  
locks/unlocks a volume. Different linked file names pointing to the same volume  
will cause this message since the server locks the linked volume, not the link name  
itself.  
You may use the Solaris 'ps -ef | grep dsmserv' command to determine if other  
dsmserv processes are running. You may remove the temporary lock files for RAW  
volumes and attempt to re-start the server ONLY if there are no other dsmserv  
processes are running.  
ANR7806W (AIX)  
Unable to open file file.  
Explanation: The server was unable to open the indicated file.  
System Action: The operation that was to use the indicated file fails. A subsequent  
unnumbered message had details from the system.  
User Response: Determine the reason for being unable to open the file and  
re-attempt the operation. Common reasons for being unable to open the file include  
providing the wrong name, having insufficient authorization to open the file and not  
being the file’s owner.  
ANR7806W (HP-UX)  
Unable to open file file.  
Explanation: The server was unable to open the indicated file.  
System Action: The operation that was to use the indicated file fails. A subsequent  
unnumbered message had details from the system.  
766  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Determine the reason for being unable to open the file and  
re-attempt the operation. Common reasons for being unable to open the file include  
providing the wrong name, having insufficient authorization to open the file and not  
being the file’s owner.  
ANR7806W (Solaris)  
Unable to open file file.  
Explanation: The server was unable to open the indicated file.  
System Action: The operation that was to use the indicated file fails. A subsequent  
unnumbered message had details from the system.  
User Response: Determine the reason for being unable to open the file and  
re-attempt the operation. Common reasons for being unable to open the file include  
providing the wrong name, having insufficient authorization to open the file and not  
being the file’s owner.  
ANR7806W (Windows NT)  
Unable to open file file.  
Explanation: The server was unable to open the indicated file.  
System Action: The operation that was to use the indicated file fails. A subsequent  
unnumbered message had details from the system.  
User Response: Determine the reason for being unable to open the file and  
re-attempt the operation. Common reasons for being unable to open the file include  
providing the wrong name, having insufficient authorization to open the file and not  
being the file’s owner. The file may be already opened by the server or another  
program.  
ANR7807W (AIX)  
Unable to get information for file file.  
Explanation: The server was unable to get information about the indicated file.  
System Action: The operation that was to use the indicated file fails. A  
subsequent, unnumbered message has details from the system.  
User Response: Determine the reason for being unable to access the file and  
re-attempt the operation. Common reasons for being unable to access the file  
include providing the wrong name, having insufficient authorization to open the file  
and not being the file’s owner.  
Tivoli Storage Manager Messages  
767  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7807I (AS/400)  
User is not authorized to reset password.  
Explanation: The user must have either all object authority, security administrator  
authority, or security officer authority.  
System Action: Server operation ends.  
User Response: None.  
ANR7807W (HP-UX)  
Unable to get information for file file.  
Explanation: The server was unable to get information about the indicated file.  
System Action: The operation that was to use the indicated file fails. A  
subsequent, unnumbered message has details from the system.  
User Response: Determine the reason for being unable to access the file and  
re-attempt the operation. Common reasons for being unable to access the file  
include providing the wrong name, having insufficient authorization to open the file  
and not being the file’s owner.  
ANR7807W (Solaris)  
Unable to get information for file file.  
Explanation: The server was unable to get information about the indicated file.  
System Action: The operation that was to use the indicated file fails. A  
subsequent, unnumbered message has details from the system.  
User Response: Determine the reason for being unable to access the file and  
re-attempt the operation. Common reasons for being unable to access the file  
include providing the wrong name, having insufficient authorization to open the file,  
not being the file’s owner, or too many soft links to the file. If trying to access a  
RAW partition, the server must be started with superuser privileges.  
ANR7808W (AS/400)  
AS/400 action returned exception exception ID.  
Explanation: The server attempts to perform the given AS/400 action, and the  
indicated exception ID is returned. The server may issue additional error messages if  
this condition prevents it from completing an operation.  
System Action: Server operation continues.  
User Response: If the exception prevents the server from completing an operation,  
evaluate both the specified exception and the AS/400 action to determine the steps  
necessary to correct the problem.  
768  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7809I (AS/400)  
Formatting file fileName at size fileSize.  
Explanation: The specified file is being formatted.  
System Action: Server operation continues.  
User Response: None.  
ANR7810W (AIX)  
Unable to create a new child process.  
Explanation: The server cannot create a new child thread.  
System Action: Server processing continues. Other error messages from the server  
component are displayed.  
User Response: Ensure that sufficient paging space is available for AIX. If the  
server has been started from a non-root user ID, ensure that the AIX process limit  
per user is sufficient for the server. The server requires approximately 24 processes,  
in addition to one process per client session, and one process for each background  
operation. Each thread started by the server is an AIX process. To change the  
number of processes per user, use the SMIT menus for System Environment, and  
choose Change / Show Characteristics of Operating System. You may also use  
SMIT to determine if the number of applications is causing a memory shortage. It  
may be necessary to decrease the maximum number of client sessions by changing  
the MAXSESSIONS option in the server options file.  
ANR7810I (AS/400)  
Connected to Tivoli event server at node name on port port.  
Explanation: The server successfully established a connection with the Tivoli  
event server on the specified node name and port.  
System Action: Server sends events to the Tivoli event server using this  
connection.  
User Response: None.  
ANR7810E (HP-UX)  
Error creating console input thread.  
Explanation: Unable to start console input thread.  
System Action: Server operation stops.  
User Response: See other issued messages.  
Tivoli Storage Manager Messages  
769  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7810E (Solaris)  
Error creating console input thread.  
Explanation: Unable to start console input thread.  
System Action: Server operation stops.  
User Response: See other issued messages.  
ANR7811E (AS/400)  
Unable to connect to the Tivoli event server at node name on port port.  
Explanation: The server was unable to established a connection with the Tivoli  
event server on the specified node name and :port.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specifed for Tivoli Port in the ADSM  
server options file is correct.  
ANR7811E (HP-UX)  
Insufficient memory for console initialization.  
Explanation: The server is unable to allocate enough memory for console  
initialization.  
System Action: Server operation stops.  
User Response: Ensure that there is sufficient paging space for HP-UX. It may be  
necessary to reduce the maximum number of client sessions by changing the  
MAXSESSIONS option in the server options file.  
ANR7811E (Solaris)  
Insufficient memory for console initialization.  
Explanation: The server is unable to allocate enough memory for console  
initialization.  
System Action: Server operation stops.  
User Response: Ensure that there is sufficient paging space for Sun Solaris. It may  
be necessary to reduce the maximum number of client sessions by changing the  
MAXSESSIONS option in the server options file.  
770  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7812E (AS/400)  
Unable to determine port of Tivoli event server on node name.  
Explanation: The server was unable to determine the TCP/IP port on which the  
Tivoli event server on node name is listening.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specified for Tivoli Port in the  
ADSM server options file is correct.  
ANR7812E (HP-UX)  
Insufficient memory to buffer console input. The following input line was  
discarded: discarded console input.  
Explanation: An error occurs during an attempt to allocate a buffer to hold the  
specified console input.  
System Action: The console input is discarded.  
User Response: Ensure that there is sufficient paging space for HP-UX. It may be  
necessary to reduce the maximum number of client sessions by changing the  
MAXSESSIONS option in the server options file.  
ANR7812E (Solaris)  
Insufficient memory to buffer console input. The following input line was  
discarded: discarded console input.  
Explanation: An error occurs during an attempt to allocate a buffer to hold the  
specified console input.  
System Action: The console input is discarded.  
User Response: Ensure that there is sufficient paging space for Sun Solaris. It may  
be necessary to reduce the maximum number of client sessions by changing the  
MAXSESSIONS option in the server options file.  
ANR7813E (AS/400)  
Unable to connect to Tivoli event server because TCP/IP is not available.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server because TCP/IP services were not available.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that TCP/IP is enabled in the server. If TCP/IP is enabled,  
use the BEGIN EVENTLOGGING TIVOLI to restart the event logging to Tivoli.  
Tivoli Storage Manager Messages  
771  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7813W (Solaris)  
Unable to create a new child thread.  
Explanation: The server cannot create a new child thread.  
System Action: Server processing continues. Other error messages from the server  
component are displayed.  
User Response: Ensure that sufficient swap space is available for Solaris. The  
amount of swap available can be obtain by executing ’swap -l’. If the number of  
free blocks is low, you can add swap files while the system is running by executing  
’mkfile’ and then ’swap -a’. See the Solaris man pages on ’mkfile’ and ’swap’ for  
more details. If the server has been started from a non-root user ID, ensure that the  
Solaris process limit per user is sufficient for the server. You can tune the  
’maxusers=##’ parameter in the /etc/system file to increase the number of number of  
users that can be on the system at one time. This will also force the kernel to  
allocate more memory/swap for user-processes. A system reboot with the  
’reconfigure’ option is required for the new user settings to take effect. It may be  
necessary to decrease the maximum number of client sessions by changing the  
MAXSESSIONS option in the server options file.  
ANR7814E (AS/400)  
User exit exit name encountered an error. Exit is disabled.  
Explanation: An error occurred when invoking the user exit.  
System Action: The user exit is disabled.  
User Response: Ensure that the program being invoked is correct. When the  
problem has been correct, END EVENTLOGGING USEREXIT and then BEGIN  
EVENTLOGGING USEREXIT to restart event logging to the user exit.  
ANR7815E (AS/400)  
Unable to find user exit exit name.  
Explanation: An error occurred when trying to resolve to the specified user exit.  
System Action: The user exit is disabled.  
User Response: Ensure that the program being invoked is correct. When the  
problem has been correct, END EVENTLOGGING USEREXIT and then BEGIN  
EVENTLOGGING USEREXIT to restart event logging to the user exit.  
ANR7816E (AS/400)  
ADSM server does not have the authority to invoke exit exit name.  
Explanation: An error occurred when trying to resolve to the specified user exit.  
System Action: The user exit is disabled.  
772  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the user starting the server or the user QADSM has  
authority to the specified exit. When the problem has been correct, END  
EVENTLOGGING USEREXIT and then BEGIN EVENTLOGGING USEREXIT to  
restart event logging to the user exit.  
ANR7817E (AS/400)  
Unable to open file file name for file exit.  
Explanation: An error occurred when trying to open the file specified for the file  
exit.  
System Action: The file exit is disabled.  
User Response: Ensure that the user starting the server or the user QADSM has  
authority to the specified file. When the problem has been correct, END  
EVENTLOGGING FILE and then BEGIN EVENTLOGGING FILE to restart event  
logging to the file.  
ANR7818E (AS/400)  
Unable to write to file file name for file exit, errno errno.  
Explanation: An error occurred when trying to write the file specified for the file  
exit.  
System Action: The file is disabled.  
User Response: Ensure that the user starting the server or the user QADSM has  
authority to the specified file. When the problem has been corrected, END  
EVENTLOGGING ... and then BEGIN EVENTLOGGING ... to restart event  
logging to the file.  
ANR7819I (AS/400)  
User AS/400 user ID issued ENDSRVADSM.  
Explanation: User issued ENDSRVADSM command.  
System Action: Server operation terminates.  
User Response: None.  
ANR7820E (AIX) Insufficient memory to buffer console input; the following input line was  
discarded: discarded console input.  
Explanation: An error occurs during an attempt to allocate a buffer large enough  
to read console input.  
System Action: The console input is discarded.  
Tivoli Storage Manager Messages  
773  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that sufficient paging space is available for AIX. You may  
also use SMIT to determine if the number of applications is causing a memory  
shortage. It may be necessary to decrease the maximum number of client sessions  
by changing the MAXSESSIONS option in the server options file.  
ANR7820E (AS/400)  
Unable to open file file name for filetext exit.  
Explanation: An error occurred when trying to open the file specified for the  
filetext exit.  
System Action: The filetext exit is disabled.  
User Response: Ensure that the user starting the server or the user QADSM has  
authority to the specified file. When the problem has been correct, END  
EVENTLOGGING FILETEXT and then BEGIN EVENTLOGGING FILETEXT to  
restart event logging to the file.  
ANR7820S (HP-UX)  
Server thread thread ID terminated in response to program abort.  
Explanation: The thread has ended due to a program abort.  
System Action: The server completes termination processing.  
User Response: Note the associated messages and contact your service  
representative.  
ANR7820S (Solaris)  
Server thread thread ID terminated in response to program abort.  
Explanation: The thread has ended due to a program abort.  
System Action: The server completes termination processing.  
User Response: Note the associated messages and call your service representative.  
ANR7820W (Windows NT)  
Insufficient Space Available for file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
There was insufficient space for the file on the disk.  
System Action: Server processing continues. The file creation request fails.  
User Response: Specify a file name on a drive with sufficient space or change the  
space request to a value consistent with the drive.  
774  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7821E (AIX) Error reading from standard input.  
Explanation: An error occurs during an attempt to read from standard input.  
System Action: The console input thread is terminated.  
User Response: Correct the standard input problem and restart the server.  
ANR7821I (HP-UX)  
Server thread thread ID terminated in response to external signal.  
Explanation: The thread has ended due to an external signal.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7821I (Solaris)  
Server thread thread ID terminated in response to external signal.  
Explanation: The thread has ended due to an external signal.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7821W (Windows NT)  
Unable to create directory when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
A new directory was being created as well, but its creation failed.  
System Action: Server processing continues. The file creation request fails.  
User Response: Specify a file name in an existing directory or change the name  
request to specify a different directory name.  
ANR7822E (AIX) Error creating console input thread.  
Explanation: Unable to start console input thread.  
System Action: Server operation stops.  
User Response: See other issued messages.  
Tivoli Storage Manager Messages  
775  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7822I (HP-UX)  
Server thread thread ID terminated in response to server shutdown.  
Explanation: The thread has ended due to a server shutdown.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7822I (Solaris)  
Server thread thread ID terminated in response to server shutdown.  
Explanation: The thread has ended due to a server shutdown.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7822W (Windows NT)  
File Already exists when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The file already exists.  
System Action: Server processing continues. The file creation request fails.  
User Response: Specify a new file name. The server will not use an existing file  
name when creating a file.  
ANR7823E (AIX) Insufficient memory for console initialization.  
Explanation: Unable to allocate enough memory for console initialization.  
System Action: Server operation stops.  
User Response: Ensure that sufficient paging space is available for AIX. You may  
also use SMIT to determine if the number of applications is causing a memory  
shortage. It may be necessary to decrease the maximum number of client sessions  
by changing the MAXSESSIONS option in the server options file.  
ANR7823W (Windows NT)  
Unable to create file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The system reported an error in creating the file.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name.  
776  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7824S (HP-UX)  
Server operation terminated.  
Explanation: An error occurs that causes server operation to stop.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7824S (Solaris)  
Server operation terminated.  
Explanation: An error occurs that causes server operation to stop.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7824W (Windows NT)  
Unable to write volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The server was able to partially write to the file before running out of space.  
System Action: The server continues processing. The file creation request fails.  
The file is still present on the system.  
User Response: Specify a new file name where there is sufficient space.  
ANR7825E (Solaris)  
Server unable to allocate a shared memory segment of size Client requested  
shared memory size.  
Explanation: A shared memory client has requested a shared memory segment  
size that Solaris is unable to fulfill.  
System Action: Client is not allowed to logon  
User Response: See the shared memory tuning guide for Solaris (a Sun  
document). You may need to increase the number/size of shared memory segments  
and/or message queues.  
ANR7825W (Windows NT)  
Unable to create volume file name. Return code=return code.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt failed with the indicated return code. The return code is an internal  
code from the server.  
System Action: The server continues processing. The file creation request fails.  
Tivoli Storage Manager Messages  
777  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Specify a new file name. The return code may also be provided to  
your service representative for interpretation.  
ANR7826W (Windows NT)  
Creation of Volume file name failed. Process was cancelled.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt was cancelled by a cancel process command.  
System Action: The server continues processing. The file creation request fails.  
User Response: The DEFINE command may be re-entered.  
ANR7830E (Solaris)  
Invalid RAW Partition Name: A valid raw partition name is in the form of  
/dev/.../rdsk/.../* , where ... means 0 or more directories.  
Explanation: Use the proper format for specifying a Raw partition. The ... means  
zero or more directories.  
System Action: Inform the user to use the right RAW partition specification.  
User Response: Have user reenter the RAW partition with the proper partition  
name.  
ANR7831E (Solaris)  
raw partition name has an existing filesystem.  
Explanation: The RAW partition specified has an existing Solaris file system on  
it. Writing to this Partition may/and most likely will destroy this filesystem.  
System Action: Warn the user that an existing filesystem for the raw partition  
specified may be destroyed if written to.  
User Response: Determine if user still wants the valid filesystem data. If not, user  
needs to destroy the filesystem by either formatting the partition, create a program  
to destroy the filesystem header information so that the server will not be able to  
detect the filesystem header information, or rearrange the starting and ending blocks  
of a partition by using the Solaris format() command. The user can read the format()  
function in the Sun manuals for further details on filesystems.  
ANR7832I (AIX) The thread process ID terminated with exit code program exit code.  
Explanation: The process has ended with the indicated exit code. This error is due  
to the problem caused and indicated by a preceding message.  
System Action: The server completes termination processing.  
User Response: None.  
778  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7832E (Solaris)  
raw partition name corresponds to a protected filesystem, such as / or /usr.  
Explanation: The RAW partition specified has an existing file system on it. This  
filesystem is the / or /usr partition. If the SERVER writes to it, it will most likely  
crash the whole operating system.  
System Action: Disallow access to this raw partition.  
User Response: Have user specify another RAW partition that is not the / or /usr.  
It may be possible that this is not the actual / or /usr partition of the boot disk.  
Check, using the Solaris format() command, if your partition name tag is labeled  
incorrectly as / or /usr.  
ANR7833S (AIX) The process thread ID terminated in response to program abort.  
Explanation: The thread has ended due to a program abort.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7833E (Solaris)  
symbolic links has too many symbolic links - the server only supports a  
maximum of 10.  
Explanation: The file specified has too many symbolic links. The server will  
follow at most 10 links before ending this symbolic link name resolution.  
System Action: Disallow access to this file  
User Response: Have the user specify the actual file, where the file is not a  
symbolic link. Using ls -l, one can see if the file is a symbolic link.  
ANR7834I (AIX) The thread thread ID terminated in response to external signal.  
Explanation: The thread has ended due to an external signal.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7834E (Solaris)  
Specified raw partition name raw partition cannot contain the 0th disk cylinder.  
Explanation: The raw partition specified has the 0th disk cylinder. The server  
should not be allowed to write into the 0th cylinder. It allowed, the disk label would  
be corrupted.  
System Action: Disallow access to this raw partition  
Tivoli Storage Manager Messages  
779  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Have the system administrator change the starting cylinder of this  
partition to a number greater than 0.  
ANR7834I (Windows NT)  
The server thread thread ID (tid Windows NT thread ID) terminated in response  
to external signal.  
Explanation: The thread has terminated due to an external signal.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7835I (AIX) The server thread thread ID terminated in response to server shutdown.  
Explanation: The thread has ended due to a server shutdown.  
System Action: The server completes termination processing.  
User Response: None.  
ANR7835E (Solaris)  
Specified raw partition name raw partition is too big for this operating system to  
handle.  
Explanation: The raw partition specified has greater than 2GB and the operating  
system is running below Solaris 2.6. Operating system below Solaris 2.6 cannot  
handle files natively more than 2GB. For operating system that is at Solaris 2.6 or  
above, the limit is 1TB.  
System Action: Disallow access to this raw partition  
User Response: Have the system administrator change the RAW partition size to  
be less than 2GB (4194303 512-byte disk blocks) for Solaris 2.5.1 or below, less  
than 1TB (2147483647 512-byte disk blocks) for Solaris 2.6 and above.  
ANR7835I (Windows NT)  
The server thread thread ID (tid Windows NT thread ID) terminated in response  
to server shutdown.  
Explanation: The thread has terminated due to a server shutdown.  
System Action: The server completes termination processing.  
User Response: None.  
780  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7836S (AIX) Server initialization terminated.  
Explanation: An error occurs that causes server initialization to end.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7838S (AIX) Server operation terminated.  
Explanation: An error occurs that causes server operation to stop.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7839E (AS/400)  
Unable to open file filespec.  
Explanation: An error occurs while the server tries to open the specified file.  
System Action: Server processing continues.  
User Response: Check job logs and previously issued messages for additional  
information regarding the error.  
ANR7840E (AS/400)  
Error reading from file filespec.  
Explanation: An error occurs while the server is trying to read from the specified  
file.  
System Action: Server processing continues.  
User Response: Check job logs and previously issued messages for additional  
information regarding the error.  
ANR7841S (AIX) Insufficient kernel memory available.  
Explanation: An error occurs due to insufficient kernel memory.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7841E (AS/400)  
Error positioning file filespec.  
Explanation: An error occurs while the server is trying to locate a record in the  
specified file.  
Tivoli Storage Manager Messages  
781  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server processing continues.  
User Response: Check job logs and previously issued messages for additional  
information regarding the error.  
ANR7842S (AIX) Monitor kernel extension not initialized.  
Explanation: The monitor kernel extension is not initialized.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7842E (AS/400)  
Error writing to file filespec.  
Explanation: An error occurs while the server is trying to write to the specified  
file.  
System Action: Server processing continues.  
User Response: Check job logs and previously issued messages for additional  
information regarding the error.  
ANR7843W (AIX)  
Unable to determine real memory size.  
Explanation: The server checks the amount of real memory in the system to  
optimize use of storage in the database buffer pool. The server uses Object Data  
Manager (ODM) to determine how much real memory is installed on the system.  
The routines used to call ODM failed or were unable to return the real memory  
size.  
System Action: Server operation continues. The server allows the data base buffer  
pool size to grow withoug taking into account real memory.  
User Response: The server may need to run as a root user to obtain this  
information.  
ANR7843W (AS/400)  
Receiver records will be truncated.  
Explanation: The receiver file records will be truncated because the file record  
length is smaller than expected.  
System Action: Server processing continues.  
User Response: None.  
782  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7843W (HP-UX)  
Unable to determine real memory size.  
Explanation: The server checks the amount of real memory in the system to  
optimize use of storage in the database buffer pool. The routines used to obtain this  
information returned a failing return code or were unable to return the real memory  
size.  
System Action: Server operation continues. The server allows the data base buffer  
pool size to grow withoug taking into account real memory.  
User Response: The server may need to run as a root user to obtain this  
information.  
ANR7843W (Solaris)  
Unable to determine real memory size.  
Explanation: The server checks the amount of real memory in the system to  
optimize use of storage in the database buffer pool. The routines used to obtain this  
information returned a failing return code or were unable to return the real memory  
size.  
System Action: Server operation continues. The server allows the data base buffer  
pool size to grow withoug taking into account real memory.  
User Response: The server may need to run as a root user to obtain this  
information.  
ANR7843W (Windows NT)  
Unable to determine real memory size.  
Explanation: The server checks the amount of real memory in the system to  
optimize use of storage in the database buffer pool. The routines used to obtain this  
information returned a failing return code or were unable to return the real memory  
size.  
System Action: Server operation continues. The server allows the data base buffer  
pool size to grow withoug taking into account real memory.  
User Response: The server may need to run as a root user to obtain this  
information.  
ANR7844W (AS/400)  
Expected receiver file size recordLength but found size recordLength.  
Explanation: The receiver file records will be truncated because the file record  
length is smaller than expected.  
System Action: Server processing continues.  
Tivoli Storage Manager Messages  
783  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR7849I (AIX) Server operation terminated - kernel extension has been reset.  
Explanation: The kernel extension has been reinitialized by the server in response  
to a previous condition for which a message has been issued.  
System Action: Server operation stops.  
User Response: None.  
ANR7850I (AIX) The process process ID has terminated on signal signal number (signal name).  
Explanation: The specified process has ended due to the specified signal.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7851S (AIX) Error resetting handler for signal signal number (signal name).  
Explanation: An error occurs resetting the specified signal handler.  
System Action: Server operation stops.  
User Response: Contact your service representative.  
ANR7852I (Windows NT)  
The current process affinity mask is: 0xThe process affinity mask..  
Explanation: The server is running on the processors indicated by the mask.  
System Action: Server operation continues.  
User Response: None.  
ANR7853W (Windows NT)  
Could not obtain the current process affinity mask. Reason: NT return code..  
Explanation: A problem was encounterd while obtaining the current process  
affinity.  
System Action: Server operation continues.  
User Response: None.  
784  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7854W (Windows NT)  
The process affinity mask (0xAffinity mask.) specified in dsmserv.opt is out of  
range.  
Explanation: The affinity mask value was out of range.  
System Action: Server operation continues.  
User Response: None.  
ANR7855W (Windows NT)  
Could not set new process affinity mask. Reason: NT return code.  
Explanation: A problem was encounterd in setting a new process affinity mask.  
System Action: Server operation continues.  
User Response: None.  
ANR7856W (Windows NT)  
The affinity mask (0xNT return code.) was set to a value other than what was  
requested  
Explanation: A new affinity mask was set but on verification it was found not to  
match what was requested.  
System Action: Server operation continues.  
User Response: None.  
ANR7860W (AIX)  
Insufficient Space Available for file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
There was insufficient space for the file in the filesystem.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a file name in a filesystem with sufficient space or change  
the space request to a value consistent with the filesystem.  
ANR7860W (AS/400)  
Insufficient Space Available for file file name.  
Explanation: ADSM was attempting to create a file with the indicated name.  
There was insufficient space for the file in the filesystem.  
System Action: ADSM continues processing. The file creation request fails.  
Tivoli Storage Manager Messages  
785  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Specify a file name in a filesystem with sufficient space or change  
the space request to a value consistent with the filesystem.  
ANR7860W (HP-UX)  
Insufficient Space Available for file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
There was insufficient space for the file in the filesystem.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a file name in a filesystem with sufficient space or change  
the space request to a value consistent with the filesystem.  
ANR7860W (Solaris)  
Insufficient Space Available for file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
There was insufficient space for the file in the filesystem.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a file name in a filesystem with sufficient space or change  
the space request to a value consistent with the filesystem.  
ANR7861W (AIX)  
Unable to create directory when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
A new directory was being created as well, but its creation failed.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a file name in an existing directory or or change the name  
request to specify a different directory name.  
ANR7861W (AS/400)  
Unable to create directory when creating volume file name.  
Explanation: ADSM was attempting to create a file with the indicated name. A  
new directory was being created as well, but its creation failed.  
System Action: ADSM continues processing. The file creation request fails.  
User Response: Specify a file name in an existing directory or or change the name  
request to specify a different directory name.  
786  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7861W (HP-UX)  
Unable to create directory when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
A new directory was being created as well, but its creation failed.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a file name in an existing directory or or change the name  
request to specify a different directory name.  
ANR7861W (Solaris)  
Unable to create directory when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
A new directory was being created as well, but its creation failed.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a file name in an existing directory or or change the name  
request to specify a different directory name.  
ANR7862W (AIX)  
File Already exists when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The file already exists.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name. The server will not use an existing file  
name when creating a file.  
ANR7862W (AS/400)  
File Already exists when creating volume file name.  
Explanation: ADSM was attempting to create a file with the indicated name. The  
file already exists.  
System Action: ADSM continues processing. The file creation request fails.  
User Response: Specify a new file name. ADSM will not use an existing file  
name when creating a file.  
ANR7862W (HP-UX)  
File Already exists when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The file already exists.  
Tivoli Storage Manager Messages  
787  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name. The server will not use an existing file  
name when creating a file.  
ANR7862W (Solaris)  
File Already exists when creating volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The file already exists.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name. The server will not use an existing file  
name when creating a file.  
ANR7863W (AIX)  
Unable to create file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The system reported an error in creating the file.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name.  
ANR7863W (AS/400)  
Unable to create file file name.  
Explanation: ADSM was attempting to create a file with the indicated name. The  
system reported an error in creating the file.  
System Action: ADSM continues processing. The file creation request fails.  
User Response: Specify a new file name.  
ANR7863W (HP-UX)  
Unable to create file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The system reported an error in creating the file.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name.  
788  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR7863W (Solaris)  
Unable to create file file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The system reported an error in creating the file.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name.  
ANR7864W (AIX)  
Unable to write volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The server was able to partially write to the file before running out of space.  
System Action: The server continues processing. The file creation request fails.  
The file is still present on the system.  
User Response: Specify a new file name where there is sufficient space.  
ANR7864W (AS/400)  
Unable to write volume file name.  
Explanation: ADSM was attempting to create a file with the indicated name.  
ADSM was able to partially write to the file before running out of space.  
System Action: ADSM continues processing. The file creation request fails. The  
file is still present on the system.  
User Response: Specify a new file name where there is sufficient space.  
ANR7864W (HP-UX)  
Unable to write volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The server was able to partially write to the file before running out of space.  
System Action: The server continues processing. The file creation request fails.  
The file is still present on the system.  
User Response: Specify a new file name where there is sufficient space.  
ANR7864W (Solaris)  
Unable to write volume file name.  
Explanation: The server was attempting to create a file with the indicated name.  
The server was able to partially write to the file before running out of space.  
Tivoli Storage Manager Messages  
789  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server continues processing. The file creation request fails.  
The file is still present on the system.  
User Response: Specify a new file name where there is sufficient space.  
ANR7865W (AIX)  
Unable to create volume file name. Return code=return code.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt failed with the indicated return code. The return code is an the server  
internal code.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name. The return code may also be provided to  
your service representative for interpretation.  
ANR7865W (AS/400)  
Unable to create volume file name. Return code=return code.  
Explanation: ADSM was attempting to create a file with the indicated name. The  
attempt failed with the indicated return code. The return code is an ADSM internal  
code.  
System Action: ADSM continues processing. The file creation request fails.  
User Response: Specify a new file name. The return code may also be provided to  
IBM service for interpretation.  
ANR7865W (HP-UX)  
Unable to create volume file name. Return code=return code.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt failed with the indicated return code. The return code is a server  
internal code.  
System Action: The server continues processing. The file creation request fails.  
User Response: Specify a new file name. The return code may also be provided to  
your service representative for interpretation.  
ANR7865W (Solaris)  
Unable to create volume file name. Return code=return code.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt failed with the indicated return code. The return code is a server  
internal code.  
System Action: The server continues processing. The file creation request fails.  
790  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Specify a new file name. The return code may also be provided to  
your service representative for interpretation.  
ANR7866W (AIX)  
Creation of Volume file name failed. Process was cancelled.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt was cancelled by a cancel process command.  
System Action: The server continues processing. The file creation request fails.  
User Response: The DEFINE command may be re-entered.  
ANR7866W (AS/400)  
Creation of Volume file name failed. Process was cancelled.  
Explanation: ADSM was attempting to create a file with the indicated name. The  
attempt was cancelled by a cancel process command.  
System Action: ADSM continues processing. The file creation request fails.  
User Response: The DEFINE command may be re-entered.  
ANR7866W (HP-UX)  
Creation of Volume file name failed. Process was cancelled.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt was cancelled by a cancel process command.  
System Action: The server continues processing. The file creation request fails.  
User Response: The DEFINE command may be re-entered.  
ANR7866W (Solaris)  
Creation of Volume file name failed. Process was cancelled.  
Explanation: The server was attempting to create a file with the indicated name.  
The attempt was cancelled by a cancel process command.  
System Action: The server continues processing. The file creation request fails.  
User Response: The DEFINE command may be re-entered.  
ANR7867W (AS/400)  
Size of file file name exceeds maximum.  
Explanation: ADSM was attempting to create a file with the indicated name. The  
size of the file exceeded the maximum allowed in the filesystem.  
Tivoli Storage Manager Messages  
791  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: ADSM continues processing. The file creation request fails.  
User Response: Specify a file size that is less than or equal to 2047MB.  
ANR7870W (AIX)  
Unable to initialize odm query. Error message from odm is odm message.  
Explanation: The server uses the AIX Object Data Manager (ODM) to check  
information about AIX. For example, the server uses ODM to detemine how much  
real memory is installed on the system. The routine used to initialize an ODM query  
failed. ODM returned an error message as indicated.  
System Action: Server operation continues. The server makes assumptions  
concerning information it could not obtain.  
User Response: The server may need to run as a root user to obtain this  
information.  
ANR7871W (AIX)  
Unable to complete odm query. Error message from odm is odm message.  
Explanation: The server uses the AIX Object Data Manager (ODM) to check  
information about AIX. For example, the server uses ODM to detemine how much  
real memory is installed on the system. The routine used to perform and ODM  
query failed. ODM returned an error message as indicated.  
System Action: Server operation continues. The server makes assumptions  
concerning information it could not obtain.  
User Response: The server may need to run as a root user to obtain this  
information.  
ANR8190I (AIX) HTTP driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
HTTP protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8190I (HP-UX)  
HTTP driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
HTTP protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
792  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8190I (Solaris)  
HTTP driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
HTTP protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8191W (AIX)  
HTTP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTP protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTP communications. This may be done by issuing the TCP/IP netstat  
-s command. If the server is brought down and then started immediately, you may  
be within the TCP/IP one minute timeout period for port reusage. Bring down the  
server, wait one minute, and then restart the server. If that does not work, it may be  
necessary to restart Windows NT.  
ANR8191W (HP-UX)  
HTTP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTP protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTP communications. This may be done by issuing the TCP/IP netstat  
-s command. If the server is brought down and then started immediately, you may  
Tivoli Storage Manager Messages  
793  
Download from Www.Somanuals.com. All Manuals Search And Download.  
be within the TCP/IP one minute timeout period for port reusage. Bring down the  
sever, wait one minute, and then restart the server. If that does not work, it may be  
necessary to restart HP-UX.  
ANR8191W (Solaris)  
HTTP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTP protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTP communications. This may be done by issuing the TCP/IP netstat  
-s command. If the server is brought down and then started immediately, you may  
be within the TCP/IP one minute timeout period for port reusage. Bring down the  
sever, wait one minute, and then restart the server.  
ANR8192I (AIX) HTTPS driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
HTTPS protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8192I (HP-UX)  
HTTPS driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
HTTPS protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8192I (Solaris)  
HTTPS driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
HTTPS protocol on the indicated port number.  
System Action: Server operation continues.  
794  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR8193W (AIX)  
HTTPS driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTPS communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTPS protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTPS communications. This may be done by issuing the TCP/IP  
netstat -s command. If the server is brought down and then started immediately, you  
may be within the TCP/IP one minute timeout period for port reusage. Bring down  
the server, wait one minute, and then restart the server.  
ANR8193W (HP-UX)  
HTTPS driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTPS communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTPS protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTPS communications. This may be done by issuing the TCP/IP  
netstat -s command. If the server is brought down and then started immediately, you  
may be within the TCP/IP one minute timeout period for port reusage. Bring down  
the sever, wait one minute, and then restart the server. If that does not work, it may  
be necessary to restart HP-UX.  
Tivoli Storage Manager Messages  
795  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8193W (Solaris)  
HTTPS driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTPS communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTPS protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTPS communications. This may be done by issuing the TCP/IP  
netstat -s command. If the server is brought down and then started immediately, you  
may be within the TCP/IP one minute timeout period for port reusage. Bring down  
the sever, wait one minute, and then restart the server. If that does not work, it may  
be necessary to restart Solaris  
ANR8194W (HP-UX)  
HTTPS driver unable to initialize due to error in secure data initialization,  
reason code reason code.  
Explanation: While initializing HTTPS communications, the server has failed  
initialize of the secure data certificate information.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTPS protocol.  
User Response: Ensure the keyring file name and keyring file password are  
correct and that the password has not expired. Check for earlier SKIT messages  
which may indicate the real problem. Replace keyring if necessary and re-start the  
server.  
ANR8200I (AIX) TCP/IP driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients that use the  
TCP/IP protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
796  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8200I (AS/400)  
TCP/IP driver is ready for connection with clients on port port number.  
Explanation: The ADSM server can accept sessions with clients using the TCP/IP  
communication protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8200I (HP-UX)  
TCP/IP driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients using the  
TCP/IP protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8200I (Solaris)  
TCP/IP driver ready for connection with clients on port port number.  
Explanation: The server is now able to accept sessions with clients using the  
TCP/IP protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8200I (Windows NT)  
TCP/IP driver ready for connection with clients on port port number.  
Explanation: The server can now accept sessions with clients using the TCP/IP  
protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8201W (AIX)  
Unable to initialize TCP/IP driver - insufficient memory.  
Explanation: Because the operating system rejects a memory allocation request,  
the server cannot start communications through TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
Tivoli Storage Manager Messages  
797  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that sufficient paging space is available for AIX. You may  
also use SMIT to determine if the number of applications is causing a memory  
shortage. It may be necessary to decrease the maximum number of client sessions  
by changing the MAXSESSIONS option in the server options file.  
ANR8201W (AS/400)  
Unable to initialize TCP/IP driver - insufficient memory.  
Explanation: The ADSM server cannot communicate by way of TCP/IP. A  
memory allocation request has been rejected by the operating system.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: Contact your service representative.  
ANR8201E (HP-UX)  
Unable to initialize TCP/IP driver - socket creation failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
creation error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8201E (Solaris)  
Unable to initialize TCP/IP driver - socket creation failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
creation error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8201W (Windows NT)  
Unable to initialize TCP/IP driver - insufficient memory.  
Explanation: The server is unable to communicate by way of TCP/IP. A memory  
allocation request has been rejected by the operating system.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
798  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that there is sufficient space for the Windows NT paging  
file. Click on the system icon in the Windows NT control panel and then click on  
the virtual memory button. Refer to the online help for instructions on how to  
increase the amount of virtual memory.  
ANR8202W (AIX)  
Unable to initialize TCP/IP driver - error creating acceptor socket. Reason code  
reason code.  
Explanation: Because TCP/IP rejects a request for a socket on which to listen, the  
server cannot start communications through TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not started, use  
the HALT command from a server prompt to stop the server and restart it.  
ANR8202W (AS/400)  
Unable to initialize TCP/IP driver - error creating acceptor socket.  
Explanation: The ADSM server cannot communicate by way of TCP/IP. TCP/IP  
has rejected a request for a socket on which the server listens.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not started, issue  
the ADSM HALT command to stop the server, and then restart the server.  
ANR8202E (HP-UX)  
Unable to initialize TCP/IP driver - socket bind operation for port TCP port  
number failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
binding error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server. This message may also  
result from more than one server running on the same machine with the same  
TCP/IP port number. Make sure that the dsmserv.opt file TCPPort option is different  
for each server.  
Tivoli Storage Manager Messages  
799  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8202E (Solaris)  
Unable to initialize TCP/IP driver - socket bind operation for port TCP port  
number failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
binding error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server. This message may also  
result from more than one server running on the same machine with the same  
TCP/IP port number. Make sure that the dsmserv.opt file TCPPort option is different  
for each server.  
ANR8202W (Windows NT)  
Unable to initialize TCP/IP driver - error creating acceptor socket.  
Explanation: The server is unable to communicate by way of TCP/IP. TCP/IP has  
rejected a request for a socket on which the server listens.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not started, issue  
the HALT command to stop the server, and then restart the server.  
ANR8203W (AIX)  
Unable to establish TCP connection - accept error.  
Explanation: The server cannot accept a client session due to a failure in TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not started, use  
the HALT command from a server prompt to terminate the server and restart it.  
ANR8203W (AS/400)  
TCP has run out of buffer space - server will retry when buffer space is  
available.  
Explanation: The ADSM server cannot send data to clients because no buffer  
space is available in TCP/IP data buffer.  
800  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. The server continues to communicate  
with clients but performance is degraded.  
User Response: Ensure that not too many TCP/IP sessions are running at the same  
time. Increasing TCP/IP data buffers can alleviate the problem.  
ANR8203E (HP-UX)  
Unable to initialize TCP/IP driver - listen operation failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
listen error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8203E (Solaris)  
Unable to initialize TCP/IP driver - listen operation failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
listen error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8203W (Windows NT)  
Unable to establish TCP connection - accept error.  
Explanation: The server cannot accept a client session due to failure in TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not started, issue  
the HALT command to stop the server, and then restart the server.  
ANR8204W (AIX)  
Unable to establish TCP connection - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
Tivoli Storage Manager Messages  
801  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that sufficient paging space is available for AIX. You may  
also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8204W (AS/400)  
Unable to establish TCP connection - insufficient memory.  
Explanation: The ADSM server cannot accept a client session due to a memory  
allocation request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Contact your service representative.  
ANR8204E (HP-UX)  
Unable to initialize TCP/IP driver - thread creation failed.  
Explanation: The server is unable to initialize the TCP/IP driver due to an error  
creating a server thread.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: This error often results from a lack of memory. Ensure that your  
system has sufficient paging space to support the current activities.  
ANR8204E (Solaris)  
Unable to initialize TCP/IP driver - thread creation failed.  
Explanation: The server is unable to initialize the TCP/IP driver due to an error  
creating a server thread.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: This error often results from a lack of memory. Ensure that your  
system has sufficient paging space to support the current activities.  
ANR8204W (Windows NT)  
Unable to establish TCP connection - insufficient memory.  
Explanation: The server is unable to accept a client session due to a memory  
allocation request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
802  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that there is sufficient space for the Windows NT paging  
file. Click on the system icon in the Windows NT control panel and then click on  
the virtual memory button. Refer to the online help for instructions on how to  
increase the amount of virtual memory. You may also wish to cut down on the  
maximum number of sessions that the server can accept with the MAXSESSIONS  
option in the server options file.  
ANR8205W (AIX)  
Unable to establish TCP connection - server HALT in progress.  
Explanation: The server cannot accept a client session due to server HALT  
processing that is in progress.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: None.  
ANR8205W (AS/400)  
Unable to initialize TCP/IP driver - no TCP/IP service.  
Explanation: The ADSM server cannot communicate by way of TCP/IP. No  
TCP/IP service exists.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: Ensure that TCP/IP is properly installed on your system, and has  
been started on your system. Issue the TCP/IP ping command to your own address  
to verify that TCP/IP is installed and active.  
ANR8205E (HP-UX)  
Terminating TCP/IP driver - accept operation failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
accept error.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8205E (Solaris)  
Terminating TCP/IP driver - socket accept operation failed; error error code.  
Explanation: The server is unable to initialize the TCP/IP driver due to a socket  
accept error.  
Tivoli Storage Manager Messages  
803  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but TCP/IP support is inoperative.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8205W (Windows NT)  
Unable to establish TCP connection - server HALT in progress.  
Explanation: The server is unable to accept a client session due to server HALT  
processing that is in progress.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: None.  
ANR8206W (AIX)  
Socket socket (session session number) closed abruptly.  
Explanation: The server detects that the indicated session on the specified TCP/IP  
socket is closed outside of the server.  
System Action: Server operation continues, but the session is ended.  
User Response: None.  
ANR8206W (AS/400)  
TCPIP is not available.  
Explanation: QTCP is not in the liblist of job description QADSM. Refer to  
ADSM Installing Server and Admin Client for more information.  
System Action: Server operation continues, but TCPIP is not available.  
User Response: None.  
ANR8206E (HP-UX)  
Unable to establish TCP/IP session - invalid host address IP host address (port  
port number).  
Explanation: The server is unable to establish a session because the designated  
address or port number is not valid.  
System Action: Server operation continues.  
User Response: Ensure that the specified host name is valid and is accessible over  
the network. If the TCPCLIENTPort option is specified for the remote system,  
ensure it does not conflict with another application.  
804  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8206E (Solaris)  
Unable to establish TCP/IP session - invalid host address IP host address (port  
port number).  
Explanation: The server is unable to establish a session because the designated  
address or port number is not valid.  
System Action: Server operation continues.  
User Response: Ensure that the specified host name is valid and is accessible over  
the network. If the TCPCLIENTPort option is specified for the remote system,  
ensure it does not conflict with another application.  
ANR8207W (AIX)  
TCP/IP driver unable to initialize due to socket initialization error.  
Explanation: While initializing TCP/IP communications, the server fails to set up  
an interface with TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP has been started and is active on your system.  
You may issue the TCP/IP ping command to your own address to verify that TCP/IP  
is both started and active.  
ANR8207W (AS/400)  
TCP/IP driver unable to initialize due to socket initialization error.  
Explanation: While initializing TCP/IP communications, ADSM has failed to set  
up an interface with TCP/IP for AS/400.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: Ensure that TCP/IP is properly installed on your system, and has  
been started on your system. Issue the TCP/IP ping command to your own address  
to verify that TCP/IP is both installed and active.  
ANR8207E (HP-UX)  
Unable to establish TCP/IP session with IP host address due to memory  
shortage.  
Explanation: The server is unable to establish a session because of a memory  
shortage condition.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
805  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that your system has sufficient paging space to support the  
current level of system activities.  
ANR8207E (Solaris)  
Unable to establish TCP/IP session with IP host address due to memory  
shortage.  
Explanation: The server is unable to establish a session because of a memory  
shortage condition.  
System Action: Server operation continues.  
User Response: Ensure that your system has sufficient paging space to support the  
current level of system activities.  
ANR8207W (Windows NT)  
TCP/IP driver unable to initialize due to socket initialization error.  
Explanation: While initializing TCP/IP communications, the server has failed to  
set up an interface with TCP/IP for Windows NT.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is properly installed on your system. Ensure  
that TCP/IP has been started on your system. Issue the TCP/IP ping command to  
your own address to verify that TCP/IP is both installed and active.  
ANR8208W (AIX)  
TCP/IP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing TCP/IP communications, the server fails to  
connect to a master socket on which to listen for clients. The reason code is the  
return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option by issuing the TCP/IP  
netstat command. If HTTP is also in use for client sessions, ensure that the same  
port number is not specified for both TCP/IP and HTTP communications. If the  
server was brought down and client sessions were active, it may be necessary to  
terminate the client sessions on the client systems before the port can be freed.  
806  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8208W (AS/400)  
TCP/IP driver unable to initialize due to error in BINDing to Port port.  
Explanation: While initializing TCP/IP communications, ADSM has failed to  
connect to a master socket on which to listen for clients.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. This may be done by  
issuing the TCP/IP NETSTAT command. If the server is halted and then restarted  
immediately, you may be within the TCP/IP one minute timeout period for port  
reusage. Halt the server, wait one minute, and then restart the server.  
ANR8208E (HP-UX)  
Unable to establish TCP/IP session with IP host address - socket creation failed;  
error error code.  
Explanation: The server is unable to establish a session because of a socket  
creation error.  
System Action: Server operation continues.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8208E (Solaris)  
Unable to establish TCP/IP session with IP host address - socket creation failed;  
error error code.  
Explanation: The server is unable to establish a session because of a socket  
creation error.  
System Action: Server operation continues.  
User Response: Ensure that TCP/IP is operational on your system by using the  
ping command with your TCP/IP address as a target. If TCP/IP is not active on your  
system, you must activate it; then halt and restart the server.  
ANR8208W (Windows NT)  
TCP/IP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing TCP/IP communications, the server has failed to  
connect to a master socket on which to listen for clients. The reason code is the  
return code from the TCP/IP bind API.  
Tivoli Storage Manager Messages  
807  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If HTTP is also in use for  
client sessions, ensure that the same port number is not specified for both TCP/IP  
and HTTP communications. This may be done by issuing the TCP/IP netstat -s  
command. If the server is brought down and then started immediately, you may be  
within the TCP/IP one minute timeout period for port reusage. Bring down the  
server, wait one minute, and then restart the server. If that does not work, it may be  
necessary to restart Windows NT.  
ANR8209W (AIX)  
TCP/IP driver unable to initialize due to error in LISTENing on the specified  
Port, reason code reason code.  
Explanation: While attempting to listen for session requests from clients using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP listen API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is running properly by issuing the TCP/IP  
netstat -s and ping commands to other nodes on your network. It may be possible to  
bring the server down and restart it to allow additional client sessions to start.  
ANR8209W (AS/400)  
TCP/IP driver unable to initialize due to error in LISTENing on the specified  
Port.  
Explanation: While attempting to listen for session requests from clients using  
TCP/IP, TCP/IP returns an error.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the TCP/IP communication protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP NETSTAT and ping commands to other nodes on your network.  
It may be possible to correct this condition by restarting the server.  
ANR8209E (HP-UX)  
Unable to establish TCP/IP session with IP host address - connection refused.  
Explanation: The server is unable to establish a session because the remote  
system refused the connection request.  
System Action: Server operation continues.  
808  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Ensure that the client options file specifies the  
correct TCPServeraddress and TCPPort of the server you are attempting to contact.  
ANR8209E (Solaris)  
Unable to establish TCP/IP session with IP host address - connection refused.  
Explanation: The server is unable to establish a session because the remote  
system refused the connection request.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Ensure that the client options file specifies the  
correct TCPServeraddress and TCPPort of the server you are attempting to contact.  
ANR8209W (Windows NT)  
TCP/IP driver unable to initialize due to error in LISTENing on the specified  
Port, reason code reason code.  
Explanation: While attempting to listen for session requests from clients using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP listen API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP netstat -s and ping commands to other nodes on your network. It  
may be possible to correct this condition by restarting the server.  
ANR8210W (AIX)  
TCP/IP driver is terminating due to error in accepting a new session, reason  
code reason code.  
Explanation: While attempting to accept a session request from a client using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP accept API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP netstat -s and ping commands to other nodes on your network. It  
may be possible to bring the server down and restart it to allow additional client  
sessions to start.  
Tivoli Storage Manager Messages  
809  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8210W (AS/400)  
TCP/IP driver is terminating due to error in accepting a new session.  
Explanation: While attempting to accept a session request from a client using  
TCP/IP, TCP/IP returns an error.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the TCP/IP communication protocol.  
User Response: Ensure that TCP/IP is running properly. It may be possible to halt  
the server and start it again to allow additional client sessions to start.  
ANR8210E (HP-UX)  
Unable to establish TCP/IP session with IP host address - connection request  
timed out.  
Explanation: The server is unable to establish a session because the remote  
system did not respond to the connection request.  
System Action: Server operation continues.  
User Response: Ensure the following:  
The specified remote system is operational and is properly configured to run  
TCP/IP.  
The client options file specifies the correct TCPServeraddress and TCPPort of  
the server you are attempting to contact.  
Necessary gateways and routers are functioning properly.  
ANR8210E (Solaris)  
Unable to establish TCP/IP session with IP host address - connection request  
timed out.  
Explanation: The server is unable to establish a session because the remote  
system did not respond to the connection request.  
System Action: Server operation continues.  
User Response: Ensure the following:  
The specified remote system is operational and is properly configured to run  
TCP/IP.  
The client options file specifies the correct TCPServeraddress and TCPPort of  
the server you are attempting to contact.  
Necessary gateways and routers are functioning properly.  
810  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8210W (Windows NT)  
TCP/IP driver is terminating due to error in accepting a new session, reason  
code reason code.  
Explanation: While attempting to accept a session request from a client using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP accept API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the TCP/IP protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP netstat -s and ping commands to other nodes on your network. It  
may be possible to bring the server down and restart it to allow additional client  
sessions to start.  
ANR8211W (AIX)  
TCP/IP driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but TCP/IP communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that sufficient  
paging space is available for AIX. You may also use SMIT to determine if the  
number of applications is causing a memory shortage. You may also decrease the  
maximum number of sessions that the server can accept with the MAXSESSIONS  
option in the server options file.  
ANR8211W (AS/400)  
An error occurs and the TCP/IP driver is not available.  
Explanation: The ADSM server cannot initialize the TCP/IP driver.  
System Action: Server operation continues, but TCP/IP communications is not  
available.  
User Response: Contact your service representative.  
ANR8211E (HP-UX)  
Unable to establish TCP/IP session with IP host address - system/network  
unreachable.  
Explanation: The server is unable to establish a session because the remote  
system or network is unreachable.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
811  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Also, ensure that necessary gateways and routers  
are functioning properly.  
ANR8211E (Solaris)  
Unable to establish TCP/IP session with IP host address - system/network  
unreachable.  
Explanation: The server is unable to establish a session because the remote  
system or network is unreachable.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Also, ensure that necessary gateways and routers  
are functioning properly.  
ANR8211W (Windows NT)  
TCP/IP driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due its inability to create a new thread of  
execution.  
System Action: Server operation continues, but TCP/IP communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8212W (AIX)  
Unable to resolve address for node name.  
Explanation: The server attempts to obtain a TCP/IP address for the indicated  
node name. The attempt is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
812  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8212W (AS/400)  
Unable to resolve TCP/IP address for node name.  
Explanation: The ADSM server attempts to obtain a TCP/IP address for the  
indicated node name. The attempt is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8212E (HP-UX)  
Unable to establish TCP/IP session with IP host address - connect failed; error  
error code.  
Explanation: The server is unable to establish a session because of a connection  
error.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
ANR8212E (Solaris)  
Unable to establish TCP/IP session with IP host address - connect failed; error  
error code.  
Explanation: The server is unable to establish a session because of a connection  
error.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
ANR8212W (Windows NT)  
Unable to resolve address for node name.  
Explanation: The server attempts to obtain a TCP/IP address for the indicated  
node name. The attempt is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
Tivoli Storage Manager Messages  
813  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8213W (AIX)  
Session open with node name timed out.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8213W (AS/400)  
Session open with node name timed out.  
Explanation: The ADSM server attempts to contact the indicated node name. The  
attempt is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network by using the TCP/IP ping command.  
ANR8213E (HP-UX)  
Session Session identifier aborted due to send error; error error code.  
Explanation: The session between the server and the specified client system  
experienced a disruptive error sending data.  
System Action: The session with the remote system is ended.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
ANR8213E (Solaris)  
Session Session identifier aborted due to send error; error error code.  
Explanation: The session between the server and the specified client system  
experienced a fatal error sending data.  
System Action: The session with the remote system is ended.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
ANR8213W (Windows NT)  
Session open with node name timed out.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful.  
814  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8214E (AIX) Session open with IP host address failed due to connection refusal.  
Explanation: The server is unable to establish a session because the remote  
system refused the connection request.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Ensure that the client options file specifies the  
correct TCPServeraddress and TCPPort of the server you are attempting to contact.  
ANR8214E (AS/400)  
Session open with IP host address failed due to connection refusal.  
Explanation: The ADSM server is unable to establish a session because the  
remote system refused the connection request.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Ensure that the client options file specifies the  
correct TCPServeraddress and TCPPort of the server you are attempting to contact.  
ANR8214E (HP-UX)  
Session Session identifier aborted due to zero-length message.  
Explanation: The session between the server and the specified client system  
experienced a disruptive error receiving data.  
System Action: The session with the remote system is ended.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
ANR8214E (Solaris)  
Session Session identifier aborted due to zero-length message.  
Explanation: The session between the server and the specified client system  
experienced a fatal error receiving data.  
System Action: The session with the remote system is ended.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
Tivoli Storage Manager Messages  
815  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8214E (Windows NT)  
Session open with IP host address failed due to connection refusal.  
Explanation: The server is unable to establish a session because the remote  
system refused the connection request.  
System Action: Server operation continues.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP. Ensure that the client options file specifies the  
correct TCPServeraddress and TCPPort of the server you are attempting to contact.  
ANR8215W (AIX)  
Session open with IP host address failed as unreachable.  
Explanation: The server is unable to establish a session because the remote  
system is unreachable.  
System Action: Server operation continues.  
User Response: Ensure that the IP host address is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8215W (AS/400)  
Session open with IP host address failed as unreachable.  
Explanation: The ADSM server is unable to establish a session because the  
remote system is unreachable.  
System Action: Server operation continues.  
User Response: Ensure that the IP host address is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8215E (HP-UX)  
Session Session identifier aborted due to receive error; error error code.  
Explanation: The session between the server and the specified client system  
experienced a disruptive error receiving data.  
System Action: The session with the remote system is ended.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
816  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8215E (Solaris)  
Session Session identifier aborted due to receive error; error error code.  
Explanation: The session between the server and the specified client system  
experienced a fatal error receiving data.  
System Action: The session with the remote system is ended.  
User Response: Ensure that the specified remote system is operational and is  
properly configured to run TCP/IP.  
ANR8215W (Windows NT)  
Session open with IP host address failed as unreachable.  
Explanation: The server is unable to establish a session because the remote  
system is unreachable.  
System Action: Server operation continues.  
User Response: Ensure that the IP host address is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8216W (AIX)  
Error sending data on socket socket number. Reason return code.  
Explanation: The server experiences an error return code from TCP/IP while  
sending data over the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate through such means as Telnet or FTP applications, which  
are part of the TCP/IP suite.  
ANR8216W (AS/400)  
Error sending data on socket socket number.  
Explanation: The ADSM server experiences an error return code from TCP/IP  
while sending data over the indicated socket. This may be a normal event if either  
side of the connection is abruptly ended by the client or server.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or the server, no response is required. Otherwise, ensure that the client  
and the server can communicate through such means as Telnet or FTP applications,  
which are part of the TCP/IP suite.  
Tivoli Storage Manager Messages  
817  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8216E (HP-UX)  
Unable to establish TCP/IP session with IP host address due to thread creation  
error.  
Explanation: The server is unable to establish a session because of an error  
creating a thread.  
System Action: Server operation continues.  
User Response: Ensure that your system has sufficient paging space to support the  
current level of system activities.  
ANR8216E (Solaris)  
Unable to establish TCP/IP session with IP host address due to thread creation  
error.  
Explanation: The server is unable to establish a session because of an error  
creating a thread.  
System Action: Server operation continues.  
User Response: Ensure that your system has sufficient paging space to support the  
current level of system activities.  
ANR8216W (Windows NT)  
Error sending data on socket socket number. Reason return code.  
Explanation: The server experiences an error return code from TCP/IP while  
sending data over the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate through such means as Telnet or FTP applications, which  
are part of the TCP/IP suite.  
ANR8217W (AIX)  
Error receiving data on socket socket number. Reason return code.  
Explanation: The server experiences an error return code from TCP/IP while  
receiving data on the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
818  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate through such means as Telnet or FTP applications, which  
are part of the TCP/IP suite.  
ANR8217W (AS/400)  
Error receiving data on socket socket number.  
Explanation: The ADSM server experiences an error return code from TCP/IP  
while receiving data on the indicated socket. This may be a normal event if either  
side of the connection is abruptly ended by the client or server.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or the server, no response is required. Otherwise, ensure that the client  
and the server can communicate through such means as Telnet or FTP applications,  
which are part of the TCP/IP suite.  
ANR8217W (HP-UX)  
TCP/IP driver is unable to set the window size to TCPWindowsize for client  
client. The default value will be used.  
Explanation: The server cannot set the window size for the indicated client to the  
requested size shown. The server uses the default window size for the indicated  
session. There may be a lack of memory for TCP/IP buffers.  
System Action: Server operation continues and the session continues with the  
default window size.  
User Response: Retry the session with a smaller window size in the options file.  
Issue the QUERY OPTION command to determine the setting of the server  
TCPWindowsize.  
ANR8217W (Solaris)  
Unable to initialize TCP/IP driver - insufficient memory.  
Explanation: Because the operating system rejects a memory allocation request,  
the server cannot start communications through TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that sufficient paging space is available for Solaris. You  
may also use ps -ef to determine if the number of applications is causing a memory  
shortage. It may be necessary to decrease the maximum number of client sessions  
by changing the MAXSESSIONS option in the server options file.  
Tivoli Storage Manager Messages  
819  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8217W (Windows NT)  
Error receiving data on socket socket number. Reason return code.  
Explanation: The server experiences an error return code from TCP/IP while  
receiving data on the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate through such means as Telnet or FTP applications, which  
are part of the TCP/IP suite.  
ANR8218W (AIX)  
Session terminated when no data was read on socket socket number.  
Explanation: The server is unable to read data on the indicated socket. This may  
be a normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate through such means as Telnet or FTP applications, which  
are part of the TCP/IP suite.  
ANR8218W (AS/400)  
Session terminated when no data read on socket socket number.  
Explanation: The ADSM server cannot read on the indicated socket. This may be  
a normal event if either side of the connection is abruptly ended by the client or  
server.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or the server, no response is required. Otherwise, ensure that the client  
and the server can communicate through such means as Telnet or FTP applications,  
which are part of the TCP/IP suite.  
ANR8218W (HP-UX)  
TCP/IP driver is unable to use the TCP/IP NODELAY option for client client.  
Explanation: The server cannot set TCP/IP NODELAY for the indicated client.  
The session proceeds with TCP/IP Delay processing in effect. This causes TCP/IP to  
buffer data prior to sending it to clients.  
820  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues and the session continues with the  
delay processing on.  
User Response: Further details for use in contacting your service representative  
can be obtained by issuing the following trace commands from an admin session or  
from the server console (proper administrative authority is required): TRACE  
ENABLE TCPINFO TRACE BEGIN tcptrace.out After a session starts and gets  
message ANR8218W, issue the following commands: TRACE FLUSH TRACE  
END This will create trace data in file tcptrace.out and will terminate the trace. This  
file should be supplied to your server representative on request.  
ANR8218W (Solaris)  
Unable to resolve address for node name.  
Explanation: The server attempts to obtain a TCP/IP address for the indicated  
node name. The attempt is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network. Use the TCP/IP ping command for this purpose.  
ANR8218W (Windows NT)  
Session terminated when no data read on socket socket number.  
Explanation: The server cannot read on the indicated socket. This may be a  
normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate through such means as Telnet or FTP applications, which  
are part of the TCP/IP suite.  
ANR8219W (AIX)  
TCP/IP driver is unable to accept a new session with client at address TCP/IP  
address due to an error in creating a new thread.  
Explanation: The server cannot accept a client session with the client at the  
indicated address due to an inability to create a new thread.  
System Action: Server operation continues, the session request fails.  
User Response: The most likely cause is lack of memory. Ensure that sufficient  
paging space is available for AIX. You may also use SMIT to determine if the  
Tivoli Storage Manager Messages  
821  
Download from Www.Somanuals.com. All Manuals Search And Download.  
number of applications is causing a memory shortage. You may also decrease the  
maximum number of sessions that the server can accept with the MAXSESSIONS  
option in the server options file.  
ANR8219W (AS/400)  
An error occurs and the TCP/IP driver is unable to accept a new session.  
Explanation: The ADSM server cannot accept a client session.  
System Action: Server operation continues, and the session request fails.  
User Response: Contact your service representative.  
ANR8219W (HP-UX)  
Unable to initialize TCP/IP driver - insufficient memory.  
Explanation: Because the operating system rejects a memory allocation request,  
the server cannot start communications through TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP protocol.  
User Response: Ensure that sufficient paging space is available for HP-UX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. It may be necessary to decrease the maximum number of client sessions  
by changing the MAXSESSIONS option in the server options file.  
ANR8219W (Solaris)  
Unable to establish TCP connection - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that sufficient paging space is available for Solaris. You  
may also use ’swap -l’ to determine the amount of swap available. You may also  
decrease the maximum number of sessions that the server can accept with the  
MAXSESSIONS option in the server options file.  
ANR8219W (Windows NT)  
TCP/IP driver is unable to accept a new session due to error in creating a new  
thread.  
Explanation: The server cannot accept a client session due to the inability to  
create a new thread.  
System Action: Server operation continues, the session request fails.  
822  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to to cut down on the maximum number of sessions that the  
server can accept with the MAXSESSIONS option in the server options file.  
ANR8220W (AIX)  
TCP/IP driver is unable to set the window size to TCPWindowsize for client  
client. The default value will be used.  
Explanation: The server cannot set the window size for the indicated client to the  
requested size shown. The server uses the default window size for the indicated  
session. There may be a lack of memory for TCP/IP buffers.  
System Action: Server operation continues and the session continues with the  
default window size.  
User Response: Retry the session with a smaller window size in the options file.  
Issue the QUERY OPTION command to determine the setting of the server  
TCPWindowsize.  
ANR8220W (AS/400)  
TCP/IP driver is unable to contact node name.  
Explanation: The ADSM server attempts to contact the indicated node name. The  
attempt is unsuccessful due to the inability to initialize a local socket.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that TCP/IP is operating properly on this node and that it  
can communicate remotely. Use the TCP/IP ping command for this purpose.  
ANR8220W (HP-UX)  
Unable to establish TCP connection - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that sufficient paging space is available for HP-UX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
Tivoli Storage Manager Messages  
823  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8220W (Solaris)  
TCP/IP driver is unable to set the window size to TCPWindowsize for client  
client. The default value will be used.  
Explanation: The server cannot set the window size for the indicated client to the  
requested size shown. The server uses the default window size for the indicated  
session. There may be a lack of memory for TCP/IP buffers.  
System Action: Server operation continues and the session continues with the  
default window size.  
User Response: Retry the session with a smaller window size in the options file.  
Issue the QUERY OPTION command to determine the setting of the server  
TCPWindowsize.  
ANR8220W (Windows NT)  
TCP/IP driver is unable to contact node name due to an output socket  
initialization error.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful due to the inability to initialize a local socket.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that TCP/IP is operating properly on this node and that it  
can communicate remotely. Use the TCP/IP ping command for this purpose.  
ANR8221W (AIX)  
TCP/IP driver is unable to use the TCP/IP NODELAY option for client client.  
Explanation: The server cannot set TCP/IP NODELAY for the indicated client.  
The session proceeds with TCP/IP Delay processing in effect. This causes TCP/IP to  
buffer data prior to sending it to clients.  
System Action: Server operation continues and the session continues with the  
delay processing on.  
User Response: Further details for use in contacting your service representative  
can be obtained by issuing the following trace commands from an admin session or  
from the server console (proper administrative authority is required): TRACE  
ENABLE TCPINFO TRACE BEGIN. After a session starts and gets message  
ANR8221W, issue the commands TRACE FLUSH TRACE END. This will create  
trace data in file tcptrace.out and will terminate the trace. This file should be  
supplied to your service representative on request.  
824  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8221W (AS/400)  
Unable to initialize TCP/IP driver - TCP/IP is not activated.  
Explanation: The ADSM server cannot communicate by way of TCP/IP. TCP/IP is  
not activated.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: Ensure that TCP/IP is properly installed on your system, and has  
been started. Issue the TCP/IP ping command to your own address to verify that  
TCP/IP is installed and active.  
ANR8221W (Solaris)  
TCP/IP driver is unable to use the TCP/IP NODELAY option for client client.  
Explanation: The server cannot set TCP/IP NODELAY for the indicated client.  
The session proceeds with TCP/IP Delay processing in effect. This causes TCP/IP to  
buffer data prior to sending it to clients.  
System Action: Server operation continues and the session continues with the  
delay processing on.  
User Response: Further details for use in contacting your service representative  
can be obtained by issuing the following trace commands from an admin session or  
from the server console (proper administrative authority is required): TRACE  
ENABLE TCPINFO TRACE BEGIN tcptrace.out After a session starts and gets  
message ANR8221W, issue the following commands: TRACE FLUSH TRACE  
END This will create trace data in file tcptrace.out and will terminate the trace. This  
file should be supplied to your service representative on request.  
ANR8221W (Windows NT)  
TCP/IP driver is unable to set the window size to TCPWindowsize for session  
session, client client. The default value will be used.  
Explanation: The server cannot set the window size for the indicated  
session/client to the requested size shown. The server will use the default window  
size for the indicated session.  
System Action: Server operation continues and the session continues with the  
default window size.  
User Response: The most likely cause is lack of memory for TCP/IP buffers. You  
may retry with a smaller TCP window size in the options file. You can issue the  
QUERY OPTION command to display the current setting of the TCP window size.  
Tivoli Storage Manager Messages  
825  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8222W (AIX)  
TCP/IP driver is unable to set the window size to TCPWindowsize for the server  
master socket. The default value will be used.  
Explanation: The server cannot set the window size for the socket on which the  
server listens to the requested size shown. The server uses the default window size  
for listening for sessions. There may be a lack of memory for TCP/IP buffers.  
System Action: Server operation continues with the default window size.  
User Response: Restart the server with a smaller window size in the options file if  
necessary. Issue the QUERY OPTION command to determine the setting of the  
server TCPWindowsize.  
ANR8222W (AS/400)  
Failure reason is given in spool file QSYSPRT.  
Explanation: The ADSM server cannot communicate by way of TCP/IP. TCP/IP is  
not activated.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the TCP/IP communication protocol.  
User Response: A spool file QSYSPRT provides the reason.  
ANR8222W (Solaris)  
Unable to establish TCP connection - server HALT in progress.  
Explanation: The server cannot accept a client session due to server HALT  
processing that is in progress.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: None.  
ANR8222W (Windows NT)  
TCP/IP driver is unable to use the TCP/IP NODELAY option for client client.  
Explanation: The server cannot set TCP/IP NODELAY for the indicated client.  
The session proceeds with TCP/IP Delay processing in effect. This causes TCP/IP to  
buffer data prior to sending it to clients.  
System Action: Server operation continues and the session continues with the  
delay processing on.  
User Response: Further details for use in contacting your service representative  
can be obtained by issuing the following trace commands from an admin session or  
from the server console (proper administrative authority is required): TRACE  
826  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENABLE TCPINFO TRACE BEGIN tcptrace.out After a session starts and gets  
message ANR8222W, issue the following commands: TRACE FLUSH TRACE  
END This will create trace data in file tcptrace.out and will terminate the trace. This  
file should be supplied to your service representative on request.  
ANR8223W (AIX)  
Unable to connect to remote system RemoteSystem due to unexpected return  
code ReturnCode  
Explanation: The server was unable to connect to a remote system due to an  
unexpected return code from the connect Application Programming Interface.  
Common return code are handled with specific messages. This return code was  
unexpected.  
System Action: Server operation continues but the connection to the remote  
system fails.  
User Response: TCP/IP return code are listed in file /usr/include/sys/errno.h and  
may provide a pointer to the underlying problem. /usr/include/sys/errno.h is part of  
fileset bos.adt.include.  
ANR8223I (AS/400)  
IPX available at address server address and port port number.  
Explanation: The ADSM server can accept sessions with clients using the IPX  
communication protocol on the indicated port number and specified server address.  
System Action: Server operation continues.  
User Response: None.  
ANR8223W (Solaris)  
TCP/IP driver is unable to accept a new session with client at address TCP/IP  
address due to an error in creating a new thread.  
Explanation: The server cannot accept a client session with the client at the  
indicated address due to an inability to create a new thread.  
System Action: Server operation continues, the session request fails.  
User Response: The most likely cause is lack of memory. Ensure that sufficient  
paging space is available for Solaris. You may also use ps -ef to determine if the  
number of applications is causing a memory shortage. You may also decrease the  
maximum number of sessions that the server can accept with the MAXSESSIONS  
option in the server options file.  
Tivoli Storage Manager Messages  
827  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8223W (Windows NT)  
Failed to connect to system at address address port port.  
Explanation: The server attempted to contact the indicated node name at the  
specified port. The attempt is unsuccessful. The target port is not valid at the target  
node.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name still has TCP/IP running and that the  
client is active in SCHEDULE mode. If the server is attempting contact with the  
SNMP subagent, ensure that the hostname and port number for the subagent is  
correct in the server options file.  
ANR8224W (AS/400)  
Unable to initialize IPX driver - error creating acceptor socket.  
Explanation: The ADSM server cannot communicate by way of IPX. IPX has  
rejected a request for a socket on which the server listens.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the IPX communication protocol.  
User Response: Ensure that IPX is operational on your system. If IPX is not  
started, issue the ADSM HALT command to stop the server, and then restart the  
server after IPX has been started.  
ANR8224W (Solaris)  
TCP/IP driver is unable to set the window size to TCPWindowsize for the server  
master socket. The default value will be used.  
Explanation: The server cannot set the window size for the socket on which the  
server listens to the requested size shown. The server uses the default window size  
for listening for sessions. There may be a lack of memory for TCP/IP buffers.  
System Action: Server operation continues with the default window size.  
User Response: Restart the server with a smaller window size in the options file if  
necessary. Issue the QUERY OPTION command to determine the setting of the  
server TCPWindowsize.  
ANR8225I (AIX) NETBIOS driver ready for connection with clients on adapter network adapter  
number.  
Explanation: The server is now able to accept sessions with clients using the  
NETBIOS protocol.  
System Action: Server operation continues.  
828  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR8225W (AS/400)  
Unable to establish IPX connection - insufficient memory.  
Explanation: The ADSM server cannot accept a client session due to a memory  
allocation request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Contact your service representative.  
ANR8225I (Windows NT)  
NETBIOS driver ready for connection with clients on adapter network adapter  
number.  
Explanation: The server is now able to accept sessions with clients using the  
NETBIOS protocol on the indicated network adapter.  
System Action: Server operation continues.  
User Response: None.  
ANR8226W (AS/400)  
IPX driver unable to initialize due to error in BINDing to Port port.  
Explanation: While initializing IPX communications, ADSM has failed to connect  
to a master socket on which to listen for clients.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the IPX communication protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If the server is halted and  
then restarted immediately, you may be within the IPX one minute timeout period  
for port reusage. Halt the server, wait one minute, and then restart the server.  
ANR8226W (Windows NT)  
Unable to initialize NETBIOS driver on adapter network adapter number.  
Explanation: The server cannot obtain sufficient NETBIOS resources to initialize  
communications on the indicated network adapter.  
System Action: Server operation continues, but the server will not accept sessions  
from clients that use the NETBIOS protocol.  
User Response: Ensure that NETBIOS is configured on the system. Ensure that all  
NETBIOS resources are not already in use. If the LAN Server or LAN Requester  
Tivoli Storage Manager Messages  
829  
Download from Www.Somanuals.com. All Manuals Search And Download.  
application is running, you have NETBIOS configured. In that case, starting the  
server prior to starting LAN Server or LAN Requester may allow the server to  
obtain the necessary NETBIOS resources.  
ANR8227W (AIX)  
NETBIOS connection terminated - insufficient memory.  
Explanation: The server cannot listen for client sessions due to a memory  
allocation request failure.  
System Action: Server operation continues, but NETBIOS sessions are not  
accepted.  
User Response: Ensure that sufficient paging space is available for AIX. You may  
also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
ANR8227W (AS/400)  
IPX driver unable to initialize due to error in LISTENing on the specified Port.  
Explanation: While attempting to listen for session requests from clients using  
IPX, IPX returns an error.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the IPX communication protocol.  
User Response: Ensure that IPX is running properly. It may be possible to correct  
this condition by restarting the server.  
ANR8227W (Windows NT)  
NETBIOS connection terminated - insufficient memory, network adapter  
network adapter number.  
Explanation: The server cannot listen for client sessions on the specified network  
adapter due to a memory allocation request failure.  
System Action: Server operation continues, but the sessions will not be accepted  
on the specified adapter. Other network adapters remain unaffected.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
830  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8228W (AIX)  
NETBIOS connection terminated - server HALT in progress.  
Explanation: The server cannot accept a client session due to server HALT  
processing that is in progress.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: None.  
ANR8228W (AS/400)  
IPX driver is terminating due to error in accepting a new session.  
Explanation: While attempting to accept a session request from a client using  
IPX, IPX returns an error.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the IPX communication protocol.  
User Response: Ensure that IPX is running properly. It may be possible to halt the  
server and start it again to allow additional client sessions to start.  
ANR8228W (Windows NT)  
NETBIOS connection terminated - server HALT in progress.  
Explanation: The server cannot accept a client session due to server HALT  
processing that is in progress.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: None.  
ANR8229W (AIX)  
Unable to add server name server name to adapter network adapter number.  
Explanation: The server cannot initialize communications processing using the  
NETBIOS protocol on the indicated network adapter because the server name  
cannot be added as a NETBIOS name on the adapter. Another system on the  
network may be using the same name for NETBIOS communications. This may be  
another server or client or a LAN Requester node.  
System Action: Server operation continues, but client sessions from clients using  
the NETBIOS protocol are not accepted on this adapter. Other adapters are not  
affected.  
Tivoli Storage Manager Messages  
831  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Change or add the NETBIOSNAME option for this adapter in  
your server options file and restart the server to allow this adapter to be used with  
NETBIOS communications.  
ANR8229W (AS/400)  
An error occurs and the IPX driver is not available.  
Explanation: The ADSM server cannot initialize the IPX driver.  
System Action: Server operation continues, but IPX communications is not  
available.  
User Response: Contact your service representative.  
ANR8229W (Windows NT)  
Unable to add server name server name to adapter network adapter number.  
Explanation: The server cannot initialize communications processing using the  
NETBIOS protocol on the indicated network adapter because the server name  
cannot be added as a NETBIOS name on the adapter.  
System Action: Server operation continues, but client sessions from clients using  
the NETBIOS protocol will not be accepted on this adapter. Other adapters are not  
affected.  
User Response: The most likely cause for this message is the presence of another  
system on the network that is using the same name for NETBIOS communications.  
This may be another server or client or a LAN Requester node. Changing or adding  
the NETBIOSNAME option for this adapter in your server options file and  
restarting the server may allow this adapter to be used with NETBIOS  
communications.  
ANR8230W (AIX)  
Unable to create thread to monitor sessions on adapter network adapter number.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure on the specified adapter.  
System Action: Server operation continues, but the session request fails.  
User Response: Ensure that sufficient paging space is available for AIX. You may  
also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
832  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8230W (AS/400)  
Error sending data on socket socket number.  
Explanation: The ADSM server experiences an error return code from IPX while  
sending data over the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended by the client or server.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or the server, no response is required. Otherwise, ensure that the client  
and the server can communicate.  
ANR8230W (Windows NT)  
Insufficient memory to start NETBIOS session on adapter network adapter  
number.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure on the specified adapter.  
System Action: Server operation continues, but the session request fails.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
ANR8231W (AIX)  
Unable to create thread to accept NETBIOS sessions.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but NETBIOS communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
Tivoli Storage Manager Messages  
833  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8231W (AS/400)  
Error receiving data on socket socket number.  
Explanation: The ADSM server experiences an error return code from IPX while  
receiving data on the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended by the client or server.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or the server, no response is required. Otherwise, ensure that the client  
and the server can communicate.  
ANR8231W (Windows NT)  
Unable to create thread to accept NETBIOS sessions.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but NETBIOS communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
ANR8232W (AIX)  
Unable to create thread to listen to NETBIOS sessions on adapter network  
adapter number.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution to monitor the indicated network adapter.  
System Action: Server operation continues, but NETBIOS communications is  
inoperative on the indicated adapter. Other adapters remain unaffected.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
834  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8232W (AS/400)  
Session terminated when no data read on socket socket number.  
Explanation: The ADSM server cannot read on the indicated socket. This may be  
a normal event if either side of the connection is abruptly ended by the client or  
server.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or the server, no response is required. Otherwise, ensure that the client  
and the server can communicate.  
ANR8232W (Windows NT)  
Unable to create thread to listen for NETBIOS sessions on adapter network  
adapter number.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution to monitor the indicated network adapter.  
System Action: Server operation continues, but NETBIOS communications is  
inoperative on the indicated adapter. Other adapters remain unaffected.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
ANR8233W (AIX)  
Unable to create thread to handle NETBIOS session session number on adapter  
network adapter number.  
Explanation: The server cannot start a new client session on the indicated adapter  
due to an inability to start a separate thread of execution for the session.  
System Action: Server operation continues, but this session request fails.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
Tivoli Storage Manager Messages  
835  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8233W (AS/400)  
An error occurs and the IPX driver is unable to accept a new session.  
Explanation: The ADSM server cannot accept a client session.  
System Action: Server operation continues, and the session request fails.  
User Response: Contact your service representative.  
ANR8233W (Windows NT)  
Unable to create thread to handle NETBIOS session session number on adapter  
network adapter number.  
Explanation: The server cannot start a new client session on the indicated adapter  
due to an inability to start a separate thread of execution for the indicated session.  
System Action: Server operation continues, but this session request fails.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS or the NETBIOSSESSIONS option, or both, in  
the server options file.  
ANR8234W (AIX)  
Error loading modname for NetBIOS communications method.  
Explanation: The server cannot load file module modname to initialize the  
NETBIOS communications driver. The dsmnetb1.drv module is for use with IBM  
AIX NETBIOS on Token-Ring/6000. The dsmnetb2.drv module is for use with the  
newer IBM NETBIOS for AIX.  
System Action: Server operation continues. NetBIOS communications is  
inoperative.  
User Response: The dsmnetb1.drv and dsmnetb2.drv modules are accessed as part  
of the load process for NetBIOS communications. Both should be in the same  
directory as the dsmserv executable or in a directory that is pointed to by the  
DSMSERV_DIR environment variable. The dsmnetb2.drv module will fail to load  
unless the STREAMS environment is active. The STREAMS environment is  
activated with the /usr/sbin/strload command. The server attempts to initialize the  
IBM AIX NETBIOS on Token-Ring/6000 environment first. If /dev/netbios does not  
open, the server attempts to initialize the IBM NETBIOS for AIX environment.  
Consequently, if you have IBM AIX NETBIOS on Token-Ring/6000, but do not  
have it available for use, you will receive this message naming dsmnetb2.drv as the  
module that failed to load.  
836  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8235W (Windows NT)  
Requested number of NETBIOS sessions are not available on adapter network  
adapter number, proceeding with available sessions.  
Explanation: The server cannot acquire the requested number of NETBIOS  
sessions for the indicated adapter. The server attempts to acquire the number of  
NETBIOS sessions as indicated by the NETBIOSSESSIONS parameter of the server  
options file or, if this option is not specified, by the MAXSESSIONS option.  
System Action: Server operation continues, but the maximum number of  
NETBIOS sessions is limited to the number of sessions that are acquired.  
User Response: Ensure that the required number of NETBIOS resources are not  
already in use. If the LAN Server or LAN Requester application is running, you  
have NETBIOS configured. In that case, starting the server prior to starting LAN  
Server or LAN Requester may allow the server to obtain the requested NETBIOS  
resources.  
ANR8236W (AIX)  
Failure while listening for NETBIOS sessions on adapter network adapter  
number, NETBIOS listen return code = listen return code.  
Explanation: The server cannot listen for NETBIOS sessions on the indicated  
adapter. The indicated listen return code has been received from the NetBIOS listen  
API.  
System Action: Server operation continues, but no additional NETBIOS sessions  
will start using the indicated adapter until the problem is corrected and the server is  
restarted.  
User Response: A NETBIOS listen failure is an indication of a network problem,  
an adapter problem, or a NETBIOS configuration problem. The following system  
configuration and system environment listen return codes (in hex) and resolution  
actions for a listen failure are found in the LAN Technical Reference IEEE 802.2  
and NETBIOS APIs.  
Return Code  
Description  
11  
Local session table full. The maximum number of sessions is in use.  
Change NETBIOS configuration to increase maximum number of  
sessions.  
19  
22  
Name conflict. Ensure that the Server NETBIOS name is not in use  
elsewhere on the network.  
Too many commands pending. The maximum number of sessions is  
in use. Change NETBIOS configuration to increase the maximum  
number of sessions.  
Tivoli Storage Manager Messages  
837  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8236W (Windows NT)  
Failure while listening for NETBIOS sessions on adapter network adapter  
number, NETBIOS listen return code = listen return code.  
Explanation: The server cannot listen for NETBIOS sessions on the indicated  
adapter. The indicated listen return code was received from the NETBIOS listen  
API. If the return code is 24, (hex 18), the listen is retried.  
System Action: Server operation continues. If the return code is 24 (hex 18), a  
new listen is setup because return code 24 indicates a temporary failure. Otherwise,  
no additional NETBIOS sessions will start using the indicated adapter until the  
problem is corrected and the server is restarted.  
User Response: A NETBIOS listen failure is an indication of a network problem,  
an adapter problem, or a NETBIOS configuration problem. The following system  
configuration and system environment listen return codes (in hex) and resolution  
actions for a listen failure are found in the IBM Local Area Network Technical  
Reference:  
Return  
Code  
11  
Description  
The local session table is full. The maximum number of sessions are  
in use. Change NETBIOS configuration to increase the maximum  
number of sessions.  
19  
22  
Name conflict. Ensure that the Server NETBIOS name is not in use  
elsewhere on the network.  
There are too many commands pending. The maximum number of  
sessions are in use. Change NETBIOS configuration to increase the  
maximum number of sessions.  
35  
The operating system resources are exhausted. A reboot is probably  
required.  
ANR8239I (AS/400)  
HTTP driver is ready for connection with clients on port port number.  
Explanation: The ADSM server can accept sessions with clients using the HTTP  
communication protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
838  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8240I (AIX) APPC driver ready for connection with clients on LU LU name.  
Explanation: The server is now able to accept sessions with clients using the  
APPC protocol through the indicated LU name.  
System Action: Server operation continues.  
User Response: None.  
ANR8240I (AS/400)  
APPC driver ready for connection with clients on LU LU name.  
Explanation: The ADSM server can accept sessions with clients using the APPC  
protocol through the indicated LU name.  
System Action: Server operation continues.  
User Response: None.  
ANR8240I (Windows NT)  
IPX/SPX driver ready for connection with clients on port port number.  
Explanation: The server can now accept sessions with clients using the IPX/SPX  
protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8241W (AIX)  
APPC connection terminated - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure. If this failure occurs prior to the first session request, APPC  
communications are not established.  
System Action: Server operation continues.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
Tivoli Storage Manager Messages  
839  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8241W (AS/400)  
APPC connection terminated - insufficient memory.  
Explanation: The ADSM server cannot accept a client session due to a memory  
allocation request failure. If this failure occurs prior to the first session request,  
APPC communications is inoperative.  
System Action: Server operation continues.  
User Response: Contact your service representative.  
ANR8241W (Windows NT)  
Unable to initialize IPX/SPX driver - insufficient memory.  
Explanation: The server is unable to communicate by way of IPX/SPX. A  
memory allocation request has been rejected by the operating system.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the IPX/SPX protocol.  
User Response: Ensure that there is sufficient space for the Windows NT paging  
file. Click on the system icon in the Windows NT control panel and then click on  
the virtual memory button. Refer to the on-line help for instructions on how to  
increase the amount of virtual memory.  
ANR8242W (AIX)  
Unable to create thread to monitor sessions on LU LU name.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution to monitor the indicated LU name.  
System Action: Server operation continues, but APPC communications are not  
established for the indicated LU name. Other LU names remain unaffected.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8242W (Windows NT)  
Unable to initialize IPX/SPX driver - error creating acceptor socket.  
Explanation: The server is unable to communicate by way of IPX/SPX. IPX/SPX  
has rejected a request for a socket on which the server listens.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the IPX/SPX protocol.  
840  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that IPX/SPX is operational on your system by using the  
network control panel applet. If IPX/SPX is not started, issue the HALT command  
to stop the server, and then restart the server.  
ANR8243W (AIX)  
Unable to open APPC connection connection: errno error number.  
Explanation: The server cannot open the connection with the client.  
System Action: Server operation continues, but APPC communications is not  
established.  
User Response: Make sure the default side information profile IDEFAULT exists  
and retry the operation.  
ANR8243W (Windows NT)  
Unable to establish IPX/SPX connection - insufficient memory.  
Explanation: The server is unable to accept a client session due to a memory  
allocation request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that there is sufficient space for the Windows NT paging  
file. Click on the system icon in the Windows NT control panel and then click on  
the virtual memory button. Refer to the on-line help for instructions on how to  
increase the amount of virtual memory. You may also wish to cut down on the  
maximum number of sessions that the server can accept with the MAXSESSIONS  
option in the server options file.  
ANR8244W (Windows NT)  
IPX/SPX driver unable to initialize due to socket initialization error.  
Explanation: While initializing IPX/SPX communications, the server has failed to  
set up an interface with IPX/SPX for Windows NT.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the IPX/SPX protocol.  
User Response: Ensure that IPX/SPX is properly installed on your system. Ensure  
that IPX/SPX has been started on your system. Verify that IPX/SPX is both installed  
and active on your system by using the network control panel applet.  
Tivoli Storage Manager Messages  
841  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8245W (AIX)  
Unable to create APPC thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but APPC communications are not  
established.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may also decrease the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8245W (Windows NT)  
IPX/SPX driver unable to initialize due to error in BINDing to Port port,  
reason code reason code.  
Explanation: While initializing IPX/SPX communications, the server has failed to  
connect to a master socket on which to listen for clients. The reason code is the  
return code from the IPX/SPX bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the IPX/SPX protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option.  
ANR8246W (AIX)  
Error sending data on connection descriptor connection descriptor. Terminating  
session session number.  
Explanation: The server experiences an error return code from APPC while  
sending data over the indicated server session number. This may be a normal event  
if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that the client and  
server can communicate over an APPC connection.  
842  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8246W (Windows NT)  
IPX/SPX driver unable to initialize due to error in LISTENing on the specified  
Port, reason code reason code.  
Explanation: While attempting to listen for session requests from clients using  
IPX/SPX, IPX/SPX returns an error. The reason code is the return code from the  
IPX/SPX listen API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the IPX/SPX protocol.  
User Response: Ensure that IPX/SPX is running properly. This may be done using  
the network control panel applet.  
ANR8247W (AIX)  
Error listening for session from APPC partner, return code from  
SET_PARTNER_LU_NAME is return code.  
Explanation: The server experiences an error return code from APPC while  
attempting to set up to listen for client sessions. The return code is from the APPC  
set partner LU name call for appc listen.  
System Action: Server operation continues. APPC communications is disabled.  
User Response: Ensure that APPC is properly configured and activated. Ensure  
that APPC can communicate with other nodes through utility programs.  
ANR8247E (AS/400)  
Device class device class not defined in device configuration information file.  
Explanation: The command that has been issued requires that the specified device  
class be defined in the device configuration information file. This definition was not  
found or the statements in the file are in the wrong order.  
System Action: The command is not processed.  
User Response: You can either reissue the command and specify a valid device  
class or refresh your device configuration information file by issuing the BACKUP  
DEVCONFIG command.  
ANR8247W (Windows NT)  
IPX/SPX driver is terminating due to error in accepting a new session, reason  
code reason code.  
Explanation: While attempting to accept a session request from a client using  
IPX/SPX, IPX/SPX returns an error. The reason code is the return code from the  
IPX/SPX accept API.  
Tivoli Storage Manager Messages  
843  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the IPX/SPX protocol.  
User Response: Ensure that IPX/SPX is running properly. This may be done using  
the network control panel applet.  
ANR8248W (AIX)  
Error on allocate listen from APPC LU name LU name, return code return code.  
Explanation: The server experiences an error return code from APPC while  
attempting to listen for client sessions on the indicated LU name. The return code is  
from the APPC allocate listen call.  
System Action: Server operation continues. APPC communications is disabled.  
User Response: Ensure that APPC is properly configured and activated. Ensure  
that APPC can communicate with other nodes through utility programs. Ensure that  
the server LU Name is properly configured within APPC.  
ANR8248E (AS/400)  
Library library not defined in device configuration information file.  
Explanation: The specified command requires that the specified library be defined  
in the device configuration information file. This definition was not found or the  
statements in the file are in the wrong order.  
System Action: The command is not processed.  
User Response: Refresh your device configuration information file by issuing the  
BACKUP DEVCONFIG command. Make sure a library is defined for the device  
class. Reissue the command.  
ANR8248W (Windows NT)  
IPX/SPX driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due its inability to create a new thread of  
execution.  
System Action: Server operation continues, but IPX/SPX communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the on-line help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
844  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8249W (AIX)  
Server Transaction Program not registered with APPC. Mask returned 0xmask,  
return code return code.  
Explanation: The server determines that the Server Transaction Program is not  
registered while initializing to communicate with clients over APPC. The indicated  
mask is returned with the indicated return code.  
System Action: Server operation continues. APPC communications is disabled.  
User Response: Ensure that APPC is properly configured and activated. Ensure  
that APPC can communicate with other nodes through utility programs. Ensure that  
ADSMSERV is properly registered as a transaction program.  
ANR8249E (AS/400)  
Drive not defined for library library in device configuration information file.  
Explanation: The specified command requires that the specified drive be defined  
in the device configuration information file for the specified library. This definition  
was not found or the statements in the file are in the wrong order.  
System Action: The command is not processed.  
User Response: Refresh your device configuration information file by issuing the  
BACKUP DEVCONFIG command. Make sure a drive is defined for the library  
associated with the device class. Reissue the command.  
ANR8249W (Windows NT)  
Unable to resolve address for node name.  
Explanation: The server attempts to obtain a IPX/SPX address for the indicated  
node name. The attempt is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network.  
ANR8250E (AIX) APPC needs a transaction program name profile name in options file.  
Explanation: The server cannot accept a client session due to the absence of a  
transaction program name profile name in the options file.  
System Action: Server operation continues.  
User Response: Supply a transaction program name profile name in the server  
options file. Stop and restart the server.  
Tivoli Storage Manager Messages  
845  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8250W (Windows NT)  
Session open with node name timed out.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network.  
ANR8251W (AIX)  
Error receiving data on connection descriptor connection descriptor.  
Terminating session session number.  
Explanation: The server encounters an error return code from APPC while  
receiving data over the indicated server session number. This may be a normal event  
if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping the  
client or server, no response is required. Otherwise, ensure that the client and server  
can communicate over an APPC connection.  
ANR8251W (Windows NT)  
Session open with node name failed due to connection refusal.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful due to a refusal by the target node.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name still has IPX/SPX running and that the  
client is active in SCHEDULE mode.  
ANR8252I (AIX) APPC driver is halting. This may take a minute.  
Explanation: The APPC driver of the server is shutting down in response to the  
HALT command.  
System Action: None.  
User Response: None.  
846  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8252W (Windows NT)  
Session open with node name failed as unreachable.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful.  
System Action: The attempt to communicate with the indicated node fails. Server  
operation continues.  
User Response: Ensure that the node name is properly specified and that it is  
accessible over the network.  
ANR8253W (AIX)  
Error killing select tid select thread id return code rc.  
Explanation: The server encounters an error return code from AIX while killing  
the select thread. This may hang the server.  
System Action: Server operation continues.  
User Response: If the server hangs, a manual kill of the server process might be  
necessary. See adsmserv.lock file in the directory where the server was started to  
find the server process id.  
ANR8253W (Windows NT)  
Error sending data on socket socket number. Reason return code.  
Explanation: The server experiences an error return code from IPX/SPX while  
sending data over the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8254W (Windows NT)  
Error receiving data on socket socket number. Reason return code.  
Explanation: The server experiences an error return code from IPX/SPX while  
receiving data on the indicated socket. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
Tivoli Storage Manager Messages  
847  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8255W (Windows NT)  
Session terminated when no data read on socket socket number.  
Explanation: The server cannot read on the indicated socket. This may be a  
normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8256W (Windows NT)  
IPX/SPX driver is unable to accept a new session due to error in creating a  
new thread.  
Explanation: The server cannot accept a client session due to the inability to  
create a new thread.  
System Action: Server operation continues, the session request fails.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the on-line help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8257W (Windows NT)  
IPX/SPX driver is unable to contact node name due to an output socket  
initialization error.  
Explanation: The server attempts to contact the indicated node name. The attempt  
is unsuccessful due to the inability to initialize a local socket.  
System Action: The attempt to communicate with the indicated node fails.  
User Response: Ensure that IPX/SPX is operating properly on this node and that it  
can communicate remotely.  
ANR8259I (AS/400)  
Request number: Waiting for the completion of an AS/400 MLB operation in  
device device name.  
Explanation: The server is waiting for an AS/400 media library operation to  
complete.  
System Action: The server waits for the AS/400 media library operation to  
complete.  
848  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR8260I (AS/400)  
Exit type EXIT exit name defined.  
Explanation: The designated exit has been successfully defined.  
System Action: The server defines and records the exit in the database.  
User Response: None.  
ANR8260I (Windows NT)  
Named Pipes driver ready for connection with clients.  
Explanation: The server is now able to accept sessions with clients using the  
Named Pipes protocol.  
System Action: Server operation continues.  
User Response: None.  
ANR8261W (AIX)  
Unable to bind to NetBIOS endpoint on adapter Adapter number Return code  
TLI error, reason code system error.  
Explanation: The server cannot initiate NetBIOS communications on the indicated  
adapter. The return codes represent the transport layer interface and system error  
codes.  
System Action: Server operation continues, but communications using the  
NetBIOS protocol are not established.  
User Response: Ensure that NetBIOS has been configured to run on this system  
through the mcsadm utility. Ensure that there is no other instance of the server  
running on this system or any other system in the network that is using the same  
NetBIOS name. Also ensure that the number of NetBIOS sessions has not been  
exceeded by using the mcsadm utility.  
ANR8261I (AS/400)  
Exit type EXIT exit name deleted.  
Explanation: The designated exit has been successfully deleted.  
System Action: The server deletes the exit from the database.  
User Response: None.  
Tivoli Storage Manager Messages  
849  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8261W (Windows NT)  
Named Pipes connection terminated - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues. Named Pipes communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8262W (AIX)  
Unable to open NetBIOS endpoint adapter. Return code = return code.  
Explanation: The server cannot initiate communications through the transport  
layer interface. The indicated return code is from the t_open call. The indicated  
endpoint is the adapter configured with the mcsadm utility.  
System Action: Server operation continues, but communications using the  
NetBIOS protocol are not established.  
User Response: Ensure that NetBIOS has been configured to run on this system  
through the mcsadm program, and that the NetBIOS stack is running. Also ensure  
that you have the ptf that allow NetBIOS over TLI to run using /usr/lib/libtli_r.a.  
ANR8262I (AS/400)  
Exit type EXIT exit name updated.  
Explanation: The designated exit has been successfully updated.  
System Action: The server updates its information about the exit.  
User Response: None.  
ANR8262W (Windows NT)  
Named Pipes driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but Named Pipes communications is  
inoperative.  
850  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the online help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8263W (AIX)  
NetBIOS driver unable to initialize due to error in LISTENing on adapter  
adapter, return code return code reason code reason code.  
Explanation: While the server attempts to listen for session requests from clients  
using NetBIOS on the indicated adapter, the transport layer interface (TLI) returns  
an error. The return code is the return code from the TLI listen API. The reason  
code is the system error code.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the NetBIOS protocol.  
User Response: Ensure that NetBIOS is still running properly and that it has not  
been intentionally or unintentionally brought down. Do this by using the mcsadm  
administrative utility.  
ANR8263W (AS/400)  
End of tape detected on device type volume volume name in drive drive name of  
library library name.  
Explanation: The server has detected end of tape for the specified volume. The  
volume reached the end of tape before arriving at the estimated capacity value  
specified in the device class.  
System Action: The current process stops writing to the specified volume. The  
status of the volume is set to read-only. The server accesses another volume if more  
data must be stored.  
User Response: Reduce the estimated capacity in the device class. You can issue  
the QUERY VOLUME command to view the actual capacity of the volume after it  
is full. Use the UPDATE DEVCLASS command to change the estimated capacity  
for the device class. Do not use the UPDATE VOLUME command to change the  
access mode.  
Tivoli Storage Manager Messages  
851  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8263W (Windows NT)  
Error sending data on Named Pipes, session session number.WriteFile Return  
code is return code.  
Explanation: The server experiences an error return code from the WriteFile  
Windows NT API while writing data to Named Pipes over the indicated session.  
This may be a normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8264I (AIX) Unable to bind to NetBIOS secondary socket. Return code TLI error, reason  
code system error.  
Explanation: The server cannot start communications with a client after listening  
for a session and finding that a request for a session is in progress. The return codes  
represent the transport layer interface and system error codes.  
System Action: Server operation continues, but this session request fails.  
User Response: Ensure that NetBIOS has been configured to run on this system  
through the mcsadm configuration program. Ensure that the number of NetBIOS  
sessions has not been exceeded.  
ANR8264W (Windows NT)  
Error reading data on Named Pipes, session session number. ReadFile return  
code is return code.  
Explanation: The server experiences an error return code from the ReadFile  
Windows NT API while reading data from Named Pipes in the indicated session.  
This may be a normal event if either side of the connection is ended abruptly.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8265W (AIX)  
Unable to establish NetBIOS connection - accept error. Return code TLI error  
Reason Code system error.  
Explanation: The server cannot accept a client session due to a failure in  
accepting the connection from NetBIOS.  
System Action: Server operation continues, but this session request fails.  
852  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that NetBIOS has been configured to run on this system  
though the mcsadm utility. Ensure that there is no other instance of the server  
running on the same system that is using the same NetBIOS name. Also check for  
the maximum number of sessions configured.  
ANR8265W (Windows NT)  
Error open Named Pipes Named Pipes name, CreateNamedPipe return code  
return code.  
Explanation: The server experiences an error return code when trying to open the  
indicated Named Pipes name for Named Pipes communication with a client. The  
return code shown is returned by the Windows NT CreateNamedPipe API.  
System Action: The session is ended. Server operation continues. Named Pipes  
communications is inoperative.  
User Response: The server may have run out of file handles. Stop and restart the  
server to reenable Named Pipes communications. It is not normal to run out of file  
handles. A system or logic error may be the underlying cause.  
ANR8266W (AIX)  
Error receiving data on session session number. Reason return code.  
Explanation: The server experiences an error return code from NetBIOS while  
receiving data on the indicated session. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that NetBIOS is  
active.  
ANR8266W (Windows NT)  
Error accepting connection on Named Pipes Named Pipes name,  
ConnectNamedPipe return code return code.  
Explanation: The server experiences an error return code when trying to complete  
a connection on the indicated Named Pipes name for Named Pipes communication  
with a client. The return code shown is returned by the Windows NT  
ConnectNamedPipe API.  
System Action: The session is ended. Server operation continues. Named Pipes  
communications is inoperative.  
User Response: A system problem may be preventing use of Named Pipes. Stop  
and restart the server to reenable Named Pipes communications.  
Tivoli Storage Manager Messages  
853  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8267W (AIX)  
Error sending data on session session number. Reason return code.  
Explanation: The server experiences an error return code from NetBIOS while  
sending data on the indicated session. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that NetBIOS is  
active.  
ANR8267W (Windows NT)  
Error initializing a security descriptor for Named Pipes Named Pipes name,  
reason: System message.  
Explanation: The server experiences an error return code when trying to initialize  
the indicated Named Pipe for Named Pipes communication with a client. The reason  
shown is returned by the Windows NT FormatMessage API.  
System Action: The session is ended. Server operation continues. Named Pipes  
communications is inoperative.  
User Response: Administrator Privileges are required. Login using an account  
with Administrator privileges and restart the server to reenable Named Pipes  
communications.  
ANR8268W (AS/400)  
AS/400 Tape Management Exit Program unavailable.  
Explanation: Based on ADSM library and device definitions, the server has  
attempted to use the AS/400 Tape Management Exit Program,  
QIBM_QTA_TAPE_TMS. The exit program is either in use or not installed. The  
exit program may be in use by a tape management system.  
System Action: Server operation continues. The server issues additional error  
messages when this condition prevents it from completing an operation.  
User Response: Ensure that the ADSM library and device definitions are correct.  
If a tape management system is available, it is possible that the ADSM definitions  
may be changed to use it. If the exit program is not installed, evaluate your system  
hardware to determine if the exit must be obtained for use by ADSM. The AS/400  
Tape Management Exit Program is part of the Media and Storage Extensions (MSE)  
feature of OS/400. Additional information about this exit program is available in  
System API Reference, SC41-3801.  
854  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8268W (Windows NT)  
Named Pipe communications were not enabled due to an error looking up the  
following NT group name: NT group name. Use the NT User manager to add  
the specified group. Members of the group will then use NT unified logon to  
access the server over Named pipes.  
Explanation: The server experiences an error return code when trying to initialize  
the indicated Named Pipe for Named Pipes communication with a client. The  
system could not find the NT Account name specified in the server options file.  
System Action: The session is ended. Server operation continues. Named Pipes  
communications is inoperative.  
User Response: To use NT unified logon specify the name of a valid Windows  
NT account or group name. Restart the server to reenable Named Pipes  
communications.  
ANR8269I (AS/400)  
Request number: exit type EXIT returned device device name.  
Explanation: The specified exit program provides the indicated device name to the  
server.  
System Action: Server operation continues.  
User Response: None.  
ANR8269W (Windows NT)  
Error opening Named Pipe Named Pipes name, reason: System message.  
Explanation: The server experiences an error return code when trying to open the  
indicated Named Pipe name for Named Pipes communication with a client. The  
reason shown is returned by the Windows NT FormatMessage API.  
System Action: The session is ended. Server operation continues. Named Pipes  
communications is inoperative.  
User Response: Consider the reason text and take appropriate action. Stop and  
restart the server to reenable Named Pipes communications.  
ANR8270I (AIX) IPX/SPX driver ready for connection with clients on socket IPX socket number.  
Explanation: The server is now able to accept sessions with clients using the  
IPX/SPX protocol on the indicated socket number.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
855  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8270I (AS/400)  
Request number: exit type EXIT returned volume volume name.  
Explanation: The specified exit program provides the indicated volume name to  
the server.  
System Action: Server operation continues.  
User Response: None.  
ANR8271W (AIX)  
Unable to bind to IPX/SPX master socket. Return code TLI error, reason code  
system error.  
Explanation: The server cannot initiate communications on the socket number  
designated for its use. The return codes represent the transport layer interface and  
system error codes.  
System Action: Server operation continues, but communications using the  
IPX/SPX protocol are not established.  
User Response: Ensure that SPX has been configured to run on this system  
through the requester configuration program. Ensure that there is no other instance  
of the server running on the same system that is using the same socket number.  
Also ensure that the number of SPX sessions has not been exceeded through other  
applications using the IPX/SPX protocol, such as NetWare for AIX clients.  
ANR8271E (AS/400)  
Request number: Error opening volume volume name on drive drive name.  
Explanation: ADSM detects an error while attempting to open a volume in the  
specified drive.  
System Action: If a volume is mounted, it is ejected. If the library is of type  
USRDFN, this media operation fails. For any other library type, the server continues  
to wait for the requested volume to be mounted.  
User Response: Ensure that a volume is inserted properly in the designated drive.  
ANR8272W (AIX)  
IPX/SPX connection terminated - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues.  
User Response: The most likely cause is a lack of memory. The system process  
table may also be full. Ensure that sufficient paging space is available for AIX. You  
856  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
may also use SMIT to determine if the number of applications is causing a memory  
shortage. You may decrease the maximum number of sessions that the server can  
accept with the MAXSESSIONS option in the server options file.  
ANR8272I (AS/400)  
Request number: Waiting for the completion of an AS/400 I/O operation on  
device device name.  
Explanation: The server is waiting for an AS/400 I/O operation to complete.  
System Action: The server waits for the AS/400 I/O operation to complete.  
User Response: None.  
ANR8273W (AIX)  
Unable to open IPX/SPX endpoint. Return code = return code.  
Explanation: The server cannot initiate communications through the transport  
layer interface. The indicated return code is from the t_open call.  
System Action: Server operation continues, but communications using the  
IPX/SPX protocol are not established.  
User Response: Ensure that SPX has been configured to run on this system  
through the NetWare for AIX configuration program, and that the Netware Protocol  
Stack daemon is running.  
ANR8273I (AS/400)  
Request number: Waiting for a reply from the AS/400 message queue associated  
with device device name.  
Explanation: The server is waiting for a reply from the AS/400 message queue  
associated with specified device.  
System Action: The server waits for a reply to the message on the queue  
associated with the given device.  
User Response: Locate the message and provide an appropriate reply.  
ANR8273I (Windows NT)  
Shared memory driver ready for connection with clients.  
Explanation: The server is now able to accept sessions with clients using the  
shared memory protocol.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
857  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8274W (AIX)  
IPX/SPX driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but IPX/SPX communications are not  
established.  
User Response: The most likely cause is a lack of memory. Ensure that sufficient  
paging space is available for AIX. You may also use SMIT to determine if the  
number of applications is causing a memory shortage. You may also decrease the  
maximum number of sessions that the server can accept with the MAXSESSIONS  
option in the server options file.  
ANR8274E (AS/400)  
Command: exit type EXIT exit name could not be located.  
Explanation: The *PGM object with the specified exit name cannot be located on  
the AS/400.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different exit name, or create  
the exit program before reissuing the command.  
ANR8274W (Windows NT)  
Shared memory communications driver is terminating due to error in creating  
a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but shared memory communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the on-line help for instructions on how to increase the amount of virtual memory.  
858  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8275W (AIX)  
IPX/SPX driver unable to initialize due to error in LISTENing on the master  
socket, return code return code reason code reason code.  
Explanation: While the server attempts to listen for session requests from clients  
using IPX/SPX, the transport layer interface (TLI) returns an error. The return code  
is the return code from the TLI listen API. The reason code is the system error  
code.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the IPX/SPX protocol.  
User Response: Ensure that IPX/SPX is still running properly and that it has not  
been intentionally or unintentionally brought down. Do this by issuing the NetWare  
for AIX transport utilities. Ensure that the Netware Protocol Stack daemon is  
running.  
ANR8275E (AS/400)  
Command: exit type EXIT is not defined.  
Explanation: The designated exit has not been defined to the server.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different exit type, or define  
the exit before reissuing the command.  
ANR8275W (Windows NT)  
Shared memory connection terminated - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues. Shared memory communications is  
inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the on-line help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
Tivoli Storage Manager Messages  
859  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8276I (AIX) Unable to bind to IPX/SPX secondary socket. Return code TLI error, reason  
code system error.  
Explanation: The server cannot start communications with a client after listening  
for a session and finding that a request for a session is in progress. The return codes  
represent the transport layer interface and system error codes.  
System Action: Server operation continues, but this session request fails.  
User Response: Ensure that SPX has been configured to run on this system  
through the requester configuration program. Ensure that there is no other instance  
of the server running on the same system which is using the same socket number.  
Also ensure that the number of SPX sessions has not been exceeded through other  
applications using the IPX/SPX protocol, such as NetWare for AIX clients.  
ANR8276E (AS/400)  
Command: exit type EXIT is already defined.  
Explanation: The designated exit cannot be defined because it already exists.  
System Action: The server does not process the command.  
User Response: None.  
ANR8276W (Windows NT)  
Shared memory connection terminated - unable to initialize. Key channel key,  
Reason: reason code.  
Explanation: The server cannot accept a client session due being unable to  
initialize shared memory.  
System Action: Server operation continues. Shared memory communications are  
inoperative.  
User Response: Try a different shared memory session.  
ANR8277W (AIX)  
Unable to establish IPX/SPX connection - accept error. Return code TLI error  
Reason Code system error.  
Explanation: The server cannot accept a client session due to a failure in  
accepting the connection from IPX/SPX.  
System Action: Server operation continues, but this session request fails.  
User Response: Ensure that SPX has been configured to run on this system  
though the requester configuration program. Ensure that there is no other instance of  
the server running on the same system that is using the same socket number. Also  
860  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ensure that the number of SPX sessions has not been exceeded through other  
applications using the IPX/SPX protocol, such as NetWare for AIX clients.  
ANR8277E (AS/400)  
Command: exit type EXIT name exit name is invalid.  
Explanation: The syntax of the specified exit program name is invalid.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify valid syntax for the exit name.  
ANR8278W (AIX)  
Error receiving data on session session number. Reason return code.  
Explanation: The server experiences an error return code from IPX/SPX while  
receiving data on the indicated session. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that IPX/SPX is  
active.  
ANR8278E (AS/400)  
Command: exit type EXIT library name is invalid or does not exist.  
Explanation: The specified AS/400 library name is invalid or it does not exist.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different library name.  
ANR8279W (AIX)  
Error sending data on session session number. Reason return code.  
Explanation: The server experiences an error return code from IPX/SPX while  
sending data on the indicated session. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that IPX/SPX is  
active.  
Tivoli Storage Manager Messages  
861  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8279E (AS/400)  
Command: exit type EXIT program name is invalid.  
Explanation: The syntax of the specified program name is invalid.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different program name.  
ANR8280W (AIX)  
Error loading dsmtli.drv for IPX/SPX or NetBIOS communications methods.  
Explanation: The server cannot load file dsmtli.drv to initialize a communications  
driver.  
System Action: Server operation continues. The communications method that was  
initializing is inoperative. This may be either NetBIOS, IPX/SPX or both, depending  
upon the contents of the server options file dsmserv.opt.  
User Response: NetWare for AIX, IBM NetBIOS and IPX Support, or AIX  
Connections must be installed on your system to use IPX/SPX communications.  
IBM NetBIOS and IPX Support or AIX Connections must be installed on your  
system to use NetBIOS communications. File libtli.a is accessed as part of the load  
process through module dsmtli.drv. This file should be in the same directory as the  
dsmserv executable or it must be in a directory that is pointed to by the  
DSMSERV_DIR environment variable.  
ANR8280E (AS/400)  
Command: One or more libraries are still defined to use the exit type EXIT.  
Explanation: The designated exit cannot be deleted because there are still libraries  
defined to use the exit.  
System Action: The server does not process the command.  
User Response: Delete all the libraries that use the exit and reissue the command.  
ANR8280I (Windows NT)  
HTTP driver ready for connection with clients on port port number.  
Explanation: The server can now accept sessions with clients using the HTTP  
protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
862  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8281W (AIX)  
Error binding dsmtli.drv for IPX/SPX or NetBIOS communications method.  
Explanation: The server cannot loadbind dsmtli.drv to initialize the IPX/SPX or  
NetBIOS communications driver after successfully loading dsmtli.drv.  
System Action: Server operation continues. IPX/SPX or NetBIOS communications  
is inoperative.  
User Response: NetWare for AIX, IPX and NetBIOS Support/6000, or AIX  
Connections must be installed on your system to use IPX/SPX communications. IPX  
and NetBIOS Support/6000 or AIX Connections must be installed on your system to  
use NetBIOS communications. File libtli.a is accessed as part of the load and  
loadbind process through module dsmtli.drv. Both files must be available for the  
load and loadbind system calls.  
ANR8281E (AS/400)  
Exit type EXIT exit name cannot be accessed.  
Explanation: The *PGM object with the given exit name cannot be accessed by  
the server. The attempt fails because the server does not have the authority  
necessary to access the designated *PGM object.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different exit name, or obtain  
the required authority to access the designated *PGM object from the security  
officer or the exit program owner before reissuing the command.  
ANR8281W (Windows NT)  
HTTP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTP protocol.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTP communications. This may be done by issuing the TCP/IP netstat  
-s command. If the server is brought down and then started immediately, you may  
be within the TCP/IP one minute timeout period for port reusage. Bring down the  
sever, wait one minute, and then restart the server. If that does not work, it may be  
necessary to restart Windows NT.  
Tivoli Storage Manager Messages  
863  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8282W (AS/400)  
Exit type EXIT is not defined.  
Explanation: The designated exit has not been defined to the server.  
System Action: Server operation continues. The server issues additional error  
messages if this condition prevents the server from completing an operation.  
User Response: Correct the problem with the specified exit program and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8282I (HP-UX)  
SNMP driver ready for connection with subagent on port port number.  
Explanation: The server can now accept sessions with SNMP subagents on the  
indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8282I (Solaris)  
SNMP driver ready for connection with subagent on port port number.  
Explanation: The server can now accept sessions with SNMP subagents on the  
indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8282I (Windows NT)  
HTTPS driver ready for connection with clients on port port number.  
Explanation: The server can now accept sessions with clients using the HTTPS  
protocol on the indicated port number.  
System Action: Server operation continues.  
User Response: None.  
ANR8283W (AS/400)  
Exit type EXIT exit name cannot be located.  
Explanation: The *PGM object with the specified exit name cannot be located on  
the AS/400.  
System Action: Server operation continues. The server issues additional error  
messages when this condition prevents it from completing an operation.  
864  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Correct the problem with the specified exit program and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8283W (HP-UX)  
SNMP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing TCP/IP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen to SNMP subagents. The  
reason code is the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from SNMP subagents to run macro commands.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP or HTTP is also  
in use for client sessions, ensure that the same port number is not specified for  
TCP/IP or HTTP communications and SNMP communications. This may be done by  
issuing the TCP/IP netstat command.  
ANR8283W (Solaris)  
SNMP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing TCP/IP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen to SNMP subagents. The  
reason code is the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from SNMP subagents to run macro commands.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP or HTTP is also  
in use for client sessions, ensure that the same port number is not specified for  
TCP/IP or HTTP communications and SNMP communications.  
ANR8283W (Windows NT)  
HTTPS driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing HTTPS communications, the server has failed to  
connect to a master TCP/IP socket on which to listen for clients. The reason code is  
the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTP protocol.  
Tivoli Storage Manager Messages  
865  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP is also in use  
for client sessions, ensure that the same port number is not specified for both  
TCP/IP and HTTPS communications. This may be done by issuing the TCP/IP  
netstat -s command. If the server is brought down and then started immediately, you  
may be within the TCP/IP one minute timeout period for port reusage. Bring down  
the sever, wait one minute, and then restart the server. If that does not work, it may  
be necessary to restart Windows NT.  
ANR8284E (AIX) The Shared Memory Communications Protocol could not initialize.  
Explanation: The server was unable to initialize the Shared Memory  
Communications Protocol due to an error.  
System Action: Server operation continues without Shared Memory  
Communications.  
User Response: Examine previous error messages for the cause of the failure.  
ANR8284W (AS/400)  
Exit type EXIT exit name cannot be accessed.  
Explanation: The *PGM object with the given exit name cannot be accessed by  
the server. The attempt fails because the server does not have the authority  
necessary to access the designated *PGM object.  
System Action: Server operation continues. The server issues additional error  
messages when this condition prevents it from completing an operation.  
User Response: Correct the problem with the specified exit program and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8284W (Windows NT)  
HTTPS driver unable to initialize due to error in secure data initialization,  
reason code reason code.  
Explanation: While initializing HTTPS communications, the server has failed to  
initialize the secure data certificate information.  
System Action: Server operation continues, but the server cannot accept sessions  
from administrative clients using HTTPS protocol.  
User Response: Ensure the keyring file name and keyring file password are  
correct and that the password has not expired. Check for earlier SKIT messages  
which may indicate the real problem. Replace keyring if necessary and re-start the  
server.  
866  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8285I (AIX) Shared Memory driver ready for connection with clients on port 1;port  
Explanation: The server is now able to accept sessions with clients using the  
Shared Memory protocol.  
System Action: Server operation continues.  
User Response: None.  
ANR8285E (AS/400)  
Exit type EXIT exit name returned a non-zero result: exit result.  
Explanation: The specified exit returned a non-zero result to the server.  
System Action: Server operation continues. The server issues additional error  
messages when this condition prevents it from completing an operation.  
User Response: Evaluate the specified exit and the given result to determine if the  
result is appropriate. If necessary, correct any problems in the exit and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8285I (HP-UX)  
Shared Memory driver ready for connection with clients on port port  
Explanation: The server is now able to accept sessions with clients using the  
Shared Memory protocol.  
System Action: Server operation continues.  
User Response: None.  
ANR8285I (Solaris)  
Shared Memory driver ready for connection with clients on port port  
Explanation: The server is now able to accept sessions with clients using the  
Shared Memory protocol.  
System Action: Server operation continues.  
User Response: None.  
ANR8285I (Windows NT)  
SNMP driver ready for connection with subagent on port port number.  
Explanation: The server can now accept sessions with SNMP subagents on the  
indicated port number.  
System Action: Server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
867  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8286W (AIX)  
Unable to initialize Shared Memory driver - insufficient memory.  
Explanation: Because the operating system rejected a memory allocation request,  
the server cannot start communications through the Shared Memory protocol.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that there is sufficient paging space for AIX. You may also  
use SMIT to determine if the number of applications is causing a memory shortage.  
It may be necessary to cut down on the maximum number of client sessions by  
changing the MAXSESSIONS option in the server options file.  
ANR8286E (AS/400)  
Exit type EXIT exit name has overwritten server memory.  
Explanation: The specified exit has performed an operation that has resulted in  
server memory being overwritten.  
System Action: Server operation continues. The server issues additional error  
messages when this condition prevents it from completing an operation.  
User Response: Correct the problem with the specified exit program and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8286W (HP-UX)  
Unable to initialize Shared Memory driver - insufficient memory.  
Explanation: Because the operating system rejected a memory allocation request,  
the server cannot start communications through the Shared Memory protocol.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that there is sufficient paging space for HP-UX. You may  
also use SAM to determine if the number of applications is causing a memory  
shortage. It may be necessary to cut down on the maximum number of client  
sessions by changing the MAXSESSIONS option in the server options file.  
ANR8286W (Solaris)  
Unable to initialize Shared Memory driver - insufficient memory.  
Explanation: Because the operating system rejected a memory allocation request,  
the server cannot start communications through the Shared Memory protocol.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
868  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that there is sufficient swap space for Solaris. It may be  
necessary to cut down on the maximum number of client sessions by changing the  
MAXSESSIONS option in the server options file.  
ANR8286W (Windows NT)  
SNMP driver unable to initialize due to error in BINDing to Port port, reason  
code reason code.  
Explanation: While initializing TCP/IP communications, the server has failed to  
connect to a master TCP/IP socket on which to listen to SNMP subagents. The  
reason code is the return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from SNMP subagents to run macro commands.  
User Response: Ensure that no other application is using the port number  
specified in the server options file with the PORT option. If TCP/IP or HTTP is also  
in use for client sessions, ensure that the same port number is not specified for  
TCP/IP or HTTP communications and SNMP communications. This may be done by  
issuing the TCP/IP netstat -s command. If the server is brought down and then  
started immediately, you may be within the TCP/IP one minute timeout period for  
port reusage. Bring down the sever, wait one minute, and then restart the server. If  
that does not work, it may be necessary to restart Windows NT.  
ANR8287W (AIX)  
Unable to initialize Shared Memory driver - error creating acceptor socket.  
Reason code reason code.  
Explanation: Because TCP/IP rejected a request for a socket on which to listen,  
the server cannot start communications through Shared Memory.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: If TCP/IP is not started, use the HALT command from any server  
prompt to stop the server, and restart it.  
ANR8287E (AS/400)  
Exception exception ID occurred in exit type EXIT exit name.  
Explanation: The specified AS/400 exception has occurred in the given exit.  
System Action: Server operation continues. The server issues additional error  
messages when this condition prevents it from completing an operation.  
User Response: Evaluate the specified exception and the given exit to determine  
the actions necessary to correct the problem. If necessary, use the UPDATE EXIT  
command to notify the server that the exit or its attributes have been changed.  
Tivoli Storage Manager Messages  
869  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8287W (HP-UX)  
Unable to initialize Shared Memory driver - error creating acceptor socket.  
Reason code reason code.  
Explanation: Because TCP/IP rejected a request for a socket on which to listen,  
the server cannot start communications through Shared Memory.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: If TCP/IP is not started, use the HALT command from any server  
prompt to stop the server, and restart it.  
ANR8287W (Solaris)  
Unable to initialize Shared Memory driver - error creating acceptor socket.  
Reason code reason code.  
Explanation: Because TCP/IP rejected a request for a socket on which to listen,  
the server cannot start communications through Shared Memory.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: If TCP/IP is not started, use the HALT command from any server  
prompt to stop the server, and restart it.  
ANR8288W (AIX)  
Unable to establish Shared Memory connection - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that there is sufficient paging space for AIX. You may also  
use SMIT to determine if the number of applications is causing a memory shortage.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8288E (AS/400)  
Request number: Device device name is not defined in library library name.  
Explanation: The designated device has been provided to the server by the  
MOUNT exit program, but the device is not defined in the given library.  
System Action: Server operation continues, but this media operation fails.  
870  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If appropriate, use the DEFINE DRIVE command to place the  
device in the specified library. If appropriate, correct the problem with the MOUNT  
exit program and use the UPDATE EXIT command to notify the server that the exit  
has been changed.  
ANR8288W (HP-UX)  
Unable to establish Shared Memory connection - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that there is sufficient paging space for HP-UX. You may  
also use SAM to determine if the number of applications is causing a memory  
shortage. You may also wish to cut down on the maximum number of sessions that  
the server can accept with the MAXSESSIONS option in the server options file.  
ANR8288W (Solaris)  
Unable to establish Shared Memory connection - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues, but the session request for this session  
fails.  
User Response: Ensure that there is sufficient swap space for Solaris. You may  
also wish to cut down on the maximum number of sessions that the server can  
accept with the MAXSESSIONS option in the server options file.  
ANR8289W (AIX)  
Shared Memory driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but Shared Memory communications  
is inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient paging space for AIX. You may also use SMIT to determine if the number  
of applications is causing a memory shortage. You may also wish to cut down on  
the maximum number of sessions that the server can accept with the  
MAXSESSIONS option in the server options file.  
Tivoli Storage Manager Messages  
871  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8289E (AS/400)  
Request number: Volume volume name cannot be mounted on device device name.  
Explanation: The designated device has been provided to the server by the  
MOUNT exit program, but the attributes of the designated volume do not match the  
attributes of the device. The volume cannot be mounted on the device.  
System Action: Server operation continues, but this media operation fails.  
User Response: Correct the problem with the MOUNT exit program and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8289W (HP-UX)  
Shared Memory driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but Shared Memory communications  
is inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient paging space for HP-UX. You may also use SAM to determine if the  
number of applications is causing a memory shortage. You may also wish to cut  
down on the maximum number of sessions that the server can accept with the  
MAXSESSIONS option in the server options file.  
ANR8289W (Solaris)  
Shared Memory driver is terminating due to error in creating a new thread.  
Explanation: The server cannot initialize due to the inability to create a new  
thread of execution.  
System Action: Server operation continues, but Shared Memory communications  
is inoperative.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient swap space for Solaris. You may also wish to cut down on the maximum  
number of sessions that the server can accept with the MAXSESSIONS option in  
the server options file.  
ANR8290W (AIX)  
Error sending data through Shared Memory. Reason return code.  
Explanation: The server experienced an error return code while sending data  
through shared memory. This may be a normal event if either side of the connection  
is abruptly ended.  
System Action: The session is ended. Server operation continues.  
872  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8290E (AS/400)  
Request number: Device Device name is not available in library Library name.  
Explanation: The designated device has been provided to the server by the  
MOUNT exit program, but the device is not available to carry out an attempted  
operation in the given library. The device can be unavailable for the following  
reasons. The device may already be in use by the server. The device may already be  
in use by another job or another system. The AS/400 status of the device may  
render it unavailable to the server. An additional message is issued by the server.  
System Action: Server operation continues, but this media operation fails.  
User Response: Correct the problem with the MOUNT exit program and use the  
UPDATE EXIT command to notify the server that the exit has been changed.  
ANR8290W (HP-UX)  
Error sending data through Shared Memory. Reason return code.  
Explanation: The server experienced an error return code while sending data  
through shared memory. This may be a normal event if either side of the connection  
is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8290W (Solaris)  
Error sending data through Shared Memory. Reason return code.  
Explanation: The server experienced an error return code while sending data  
through shared memory. This may be a normal event if either side of the connection  
is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8290I (Windows NT)  
IPX/SPX driver ready for connection with clients on socket IPX socket number.  
Explanation: The server is now able to accept sessions with clients using the  
IPX/SPX protocol on the indicated socket number.  
System Action: Server operation continues.  
Tivoli Storage Manager Messages  
873  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR8291W (AIX)  
Error receiving data through Shared Memory. Reason return code.  
Explanation: The server experienced an error return code while receiving data  
through the Shared Memory protocol. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8291W (AS/400)  
Number of automated library slots (slots in use) exceeds license terms (slots  
licensed).  
Explanation: The number of slots in use within automated libraries exceeds the  
licensed value.  
System Action: The operation completes.  
User Response: Contact your service representative to update license values for  
slots in automated libraries, or reduce the number of slots in use by issuing  
CHECKOUT LIBVOLUME commands as necessary.  
ANR8291W (HP-UX)  
Error receiving data through Shared Memory. Reason return code.  
Explanation: The server experienced an error return code while receiving data  
through the Shared Memory protocol. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8291W (Solaris)  
Error receiving data through Shared Memory. Reason return code.  
Explanation: The server experienced an error return code while receiving data  
through the Shared Memory protocol. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
874  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8291W (Windows NT)  
Unable to bind to IPX/SPX master socket. Return code = return code.  
Explanation: The server cannot initiate communications on the socket number  
designated for its use.  
System Action: Server operation continues, but communications using the  
IPX/SPX protocol is inoperative.  
User Response: Ensure that SPX has been configured to run on this system  
through the requester configuration program. Ensure that there is no other instance  
of the server running on the same system that is using the same socket number. This  
is likely to be the case if the return code is zero. Also ensure that the number of  
SPX sessions (as specified in your NET.CFG file) has not been exceeded through  
other applications using the IPX/SPX protocol.  
ANR8292W (AIX)  
Session terminated when no data was read through Shared Memory.  
Explanation: The server is unable to read data from Shared Memory. This may be  
a normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8292E (AS/400)  
CHECKIN LIBVOLUME not permitted with current license terms.  
Explanation: The CHECKIN LIBVOLUME command is not permitted because  
the current license terms do not allow it.  
System Action: The command fails.  
User Response: Contact your service representative to update license values for  
slots in automated libraries, or reduce the number of slots in use by issuing  
CHECKOUT LIBVOLUME commands as necessary.  
ANR8292W (HP-UX)  
Session terminated when no data was read through Shared Memory.  
Explanation: The server is unable to read data from Shared Memory. This may be  
a normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
Tivoli Storage Manager Messages  
875  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8292W (Solaris)  
Session terminated when no data was read through Shared Memory.  
Explanation: The server is unable to read data from Shared Memory. This may be  
a normal event if either side of the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required.  
ANR8292W (Windows NT)  
IPX/SPX connection terminated - insufficient memory.  
Explanation: The server cannot accept a client session due to a memory allocation  
request failure.  
System Action: Server operation continues.  
User Response: The most likely cause is a lack of memory. Ensure that there is  
sufficient space for the Windows NT paging file. Click on the system icon in the  
Windows NT control panel and then click on the virtual memory button. Refer to  
the on-line help for instructions on how to increase the amount of virtual memory.  
You may also wish to cut down on the maximum number of sessions that the server  
can accept with the MAXSESSIONS option in the server options file.  
ANR8293W (AIX)  
Shared Memory driver unable to initialize due to socket initialization error.  
Explanation: While initializing Shared Memory communications, the server failed  
to set up an interface with TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP has been started and is active on your system.  
You may issue the TCP/IP ping command to your own address to verify that TCP/IP  
is both started and active.  
ANR8293E (AS/400)  
This server is not licensed to support the device type device type. Device  
Support Module module number is required.  
Explanation: A DEFINE DRIVE command or a volume mount operation cannot  
be processed because the server is not licensed to support the required device type.  
876  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The operation fails.  
User Response: Contact your service representative to update the server license  
terms so that support for the required device type is enabled.  
ANR8293W (HP-UX)  
Shared Memory driver unable to initialize due to socket initialization error.  
Explanation: While initializing Shared Memory communications, the server failed  
to set up an interface with TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP has been started and is active on your system.  
You may issue the TCP/IP ping command to your own address to verify that TCP/IP  
is both started and active.  
ANR8293W (Solaris)  
Shared Memory driver unable to initialize due to socket initialization error.  
Explanation: While initializing Shared Memory communications, the server failed  
to set up an interface with TCP/IP.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP has been started and is active on your system.  
You may issue the TCP/IP ping command to your own address to verify that TCP/IP  
is both started and active.  
ANR8293W (Windows NT)  
IPX/SPX driver unable to initialize due to error in LISTENing on the master  
socket, return code = return code.  
Explanation: While attempting to listen for session requests from clients using  
IPX/SPX, the server encountered an error.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the IPX/SPX protocol.  
User Response: Ensure that IPX/SPX is still running properly and that it has not  
been intentionally or unintentionally stopped. This may be done by using the  
getipxad command to determine if an endpoint can still be opened and bound; also  
determine if you can still connect to a NetWare server.  
Tivoli Storage Manager Messages  
877  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8294W (AIX)  
Shared Memory session unable to initialize.  
Explanation: While initializing a Shared Memory communications session, an  
error occurred during initial setup.  
System Action: Server operation continues, but the session is terminated.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR8294E (AS/400)  
This server is not licensed to support library device name. Device Support  
Module module number is required.  
Explanation: Either a DEFINE LIBRARY command, a volume mount operation,  
or library initialization cannot be processed because the server is not licensed to  
support the given library.  
System Action: The operation fails.  
User Response: Contact your service representative to update the server license  
terms so that support for the given library device is enabled.  
ANR8294W (HP-UX)  
Shared Memory session unable to initialize.  
Explanation: While initializing a Shared Memory communications session, an  
error occurred during initial setup.  
System Action: Server operation continues, but the session is terminated.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR8294W (Solaris)  
Shared Memory session unable to initialize.  
Explanation: While initializing a Shared Memory communications session, an  
error occurred during initial setup.  
System Action: Server operation continues, but the session is terminated.  
User Response: Contact your service representative for assistance in resolving the  
error.  
878  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8294W (Windows NT)  
Unable to establish IPX/SPX connection - accept error. Return code = tli error.  
Explanation: The server cannot accept a client session due to a failure in  
accepting the connection from IPX/SPX.  
System Action: Server operation continues, but this session request fails.  
User Response: Ensure that SPX has been configured to run on this system  
through the requester configuration program. Ensure that there is no other instance  
of the server running on the same system that is using the same socket number.  
Also ensure that the number of SPX sessions has not been exceeded through other  
applications using the IPX/SPX protocol, such as NetWare applications.  
ANR8295W (AIX)  
Shared Memory driver unable to initialize due to error in BINDing to Port  
port, reason code reason code.  
Explanation: While initializing Shared Memory communications, the server failed  
to connect to a master socket on which to listen for clients. The reason code is the  
return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that no application is using the port number specified in  
the server options file with the SHMPORT option by issuing the TCP/IP netstat  
command. If the server was brought down and client sessions were active, it may be  
necessary to terminate the client sessions on the client systems before the port can  
be freed.  
ANR8295E (AS/400)  
Command: Current license terms do not permit this operation.  
Explanation: The specified command failed because the current license terms do  
not permit it.  
System Action: The operation fails.  
User Response: Contact your service representative to update the server license  
terms so that the requested operation can be processed.  
Tivoli Storage Manager Messages  
879  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8295W (HP-UX)  
Shared Memory driver unable to initialize due to error in BINDing to Port  
port, reason code reason code.  
Explanation: While initializing Shared Memory communications, the server failed  
to connect to a master socket on which to listen for clients. The reason code is the  
return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that no application is using the port number specified in  
the server options file with the SHMPORT option by issuing the TCP/IP netstat  
command. If the server was brought down and client sessions were active, it may be  
necessary to terminate the client sessions on the client systems before the port can  
be freed.  
ANR8295W (Solaris)  
Shared Memory driver unable to initialize due to error in BINDing to Port  
port, reason code reason code.  
Explanation: While initializing Shared Memory communications, the server failed  
to connect to a master socket on which to listen for clients. The reason code is the  
return code from the TCP/IP bind API.  
System Action: Server operation continues, but the server cannot accept sessions  
from clients using the Shared Memory protocol.  
User Response: Ensure that no application is using the port number specified in  
the server options file with the SHMPORT option by issuing the TCP/IP netstat  
command. If the server was brought down and client sessions were active, it may be  
necessary to terminate the client sessions on the client systems before the port can  
be freed.  
ANR8295W (Windows NT)  
Error sending data on session session number. Reason return code.  
Explanation: The server experiences an error return code from IPX/SPX while  
sending data on the indicated session. This may be a normal event if either side of  
the connection is abruptly ended.  
System Action: The session is ended. Server operation continues.  
User Response: If the session is ended as a result of intentionally stopping either  
the client or server, no response is required. Otherwise, ensure that IPX/SPX is still  
active.  
880  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8296W (AIX)  
Shared Memory driver unable to initialize due to error in LISTENing on the  
specified Port, reason code reason code.  
Explanation: While attempting to listen for session requests from clients using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP listen API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP is running properly by issuing the TCP/IP  
netstat -s and ping commands to other nodes on your network. It may be possible to  
bring the server down and restart it to allow additional client sessions to start.  
ANR8296E (AS/400)  
Selecting swap volume to be checked out of library library name.  
Explanation: A CHECKIN LIBVOL command was issued for a library that has  
no empty slots to hold the new cartridge. The SWAP=YES parameter was included  
in the command.  
System Action: A CHECKOUT LIBVOL command will be automatically issued,  
specifying either a scratch volume or, if there are none, a volume with the lowest  
number of mounts.  
User Response: When the CHECKOUT LIBVOL command completes, remove  
the swapped volume from the library and store it in a safe place. Issue a REPLY  
command to tell the server that the volume has been removed. The volume can be  
introduced back into the library with the CHECKIN LIBVOLUME command.  
ANR8296W (HP-UX)  
Shared Memory driver unable to initialize due to error in LISTENing on the  
specified Port, reason code reason code.  
Explanation: While attempting to listen for session requests from clients using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP listen API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP is running properly by issuing the TCP/IP  
netstat -s and ping commands to other nodes on your network. It may be possible to  
bring the server down and restart it to allow additional client sessions to start.  
Tivoli Storage Manager Messages  
881  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8296W (Solaris)  
Shared Memory driver unable to initialize due to error in LISTENing on the  
specified Port, reason code reason code.  
Explanation: While attempting to listen for session requests from clients using  
TCP/IP, TCP/IP returns an error. The reason code is the return code from the  
TCP/IP listen API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP is running properly by issuing the TCP/IP  
netstat -s and ping commands to other nodes on your network. It may be possible to  
bring the server down and restart it to allow additional client sessions to start.  
ANR8297W (AIX)  
Shared Memory driver is terminating due to error in accepting a new session,  
reason code reason code.  
Explanation: While attempting to accept a session request from a client using the  
Shared Memory protocol, TCP/IP returns an error. The reason code is the return  
code from the TCP/IP accept API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP netstat -s and ping commands to other nodes on your network. It  
may be possible to bring the server down and restart it to allow additional client  
sessions to start.  
ANR8297I (AS/400)  
Request number: device type volume volume name is required for use in library  
library name; CHECKIN LIBVOLUME required within time limit minutes.  
Explanation: A mount request has been made for a volume that is defined in a  
storage pool, but which is currently checked out of the given library.  
System Action: The server waits until it detects that the volume has been checked  
into the library, or the time limit expires.  
User Response: Obtain the required volume, and insert it into the library by  
issuing a CHECKIN LIBVOLUME command. Use the SWAP=YES option of the  
CHECKIN LIBVOLUME command if the library is currently full. This process  
allows the server to select an appropriate volume to be swapped out to make room  
for the required volume.  
882  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8297W (HP-UX)  
Shared Memory driver is terminating due to error in accepting a new session,  
reason code reason code.  
Explanation: While attempting to accept a session request from a client using the  
Shared Memory protocol, TCP/IP returns an error. The reason code is the return  
code from the TCP/IP accept API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP netstat -s and ping commands to other nodes on your network. It  
may be possible to bring the server down and restart it to allow additional client  
sessions to start.  
ANR8297W (Solaris)  
Shared Memory driver is terminating due to error in accepting a new session,  
reason code reason code.  
Explanation: While attempting to accept a session request from a client using the  
Shared Memory protocol, TCP/IP returns an error. The reason code is the return  
code from the TCP/IP accept API.  
System Action: Server operation continues, but the server cannot accept additional  
sessions from clients using the Shared Memory protocol.  
User Response: Ensure that TCP/IP is running properly. This may be done by  
issuing the TCP/IP netstat -s and ping commands to other nodes on your network. It  
may be possible to bring the server down and restart it to allow additional client  
sessions to start.  
ANR8298I (AS/400)  
Request number: Mount of device type volume volume name mount mode waiting  
for completion of exit type EXIT exit name.  
Explanation: The server is waiting for the specified exit program to complete.  
System Action: The server waits for the exit to complete.  
User Response: None.  
ANR8299I (AS/400)  
Request number: Waiting for mount of device type volume volume name mount  
mode on drive drive name in library library name.  
Explanation: The server is waiting for the specified volume mount to complete.  
System Action: The server waits for the mount to complete.  
Tivoli Storage Manager Messages  
883  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR8300E  
I/O error on library library name (OP=internal code, CC=internal code,  
KEY=internal code, ASC=internal code, ASCQ=internal code, SENSE=sense data,  
Description=error description). Refer to Appendix B in the ’Messages’ manual  
for recommended action.  
Explanation: An I/O error has occurred while operating on the designated library  
device.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the library  
was identified correctly in the DEFINE LIBRARY command, and that the library  
device is currently powered on and ready. If the library has an access door, make  
sure it is closed. The drive or library reference manual provided with the device  
usually contain tables that explain the values of the KEY, ASC, and ASCQ fields. If  
the problem persists, contact your service representative and provide the internal  
code values and sense data from this message.  
ANR8300I (AS/400)  
Request number: Select a device type device in library library name within time  
limit minutes.  
Explanation: The server requires the selection of an appropriate device in the  
designated library within the specified time limit. See associated messages for a list  
of device names.  
System Action: The server waits for a device to be selected.  
User Response: Choose a device from the list within the time limit. Use the  
REPLY command to communicate the device name to the server.  
ANR8301E  
I/O error on library library name (OP=internal code, SENSE=internal code).  
Explanation: An I/O error has occurred while operating on the designated library  
device.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the library  
was identified correctly in the DEFINE LIBRARY command, and that the library  
device is currently powered on and ready. If the library has an access door, make  
sure it is closed. If the problem persists, contact your service representative and  
provide the internal code values from this message.  
884  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8301E (AS/400)  
Error on library library name: MLD message.  
Explanation: An error has occurred while operating on the designated library  
device.  
System Action: The operation fails.  
User Response: Ensure that the MLD parameter associated with the library has  
been identified correctly in the DEFINE LIBRARY command, and that the library  
device is currently powered on and ready. If the library has an access door, make  
sure it is closed. If the problem persists, contact your service representative and  
provide the values from this message. The values can be found in Media Library  
Device Driver for Application System/400, GC35-0153.  
ANR8302E  
I/O error on drive drive name (OP=internal code, CC=internal code,  
KEY=internal code, ASC=internal code, ASCQ=internal code, SENSE=sense data,  
Description=error description). Refer to Appendix B in the ’Messages’ manual  
for recommended action.  
Explanation: An I/O error has occurred while operating on the designated drive.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive was  
identified correctly in the DEFINE DRIVE command, and that the device is  
currently powered on and ready. The drive or library reference manual provided  
with the device usually contain tables that explain the values of the KEY, ASC, and  
ASCQ fields. If the problem persists, contact your service representative and  
provide the internal code values and sense data from this message.  
ANR8302I (AS/400)  
Request number: Mount device type volume volume name mount mode on an  
appropriate device in library library name within time limit minutes.  
Explanation: The server requires that the specified volume be mounted on an  
appropriate device in the designated library. See associated messages for a list of  
device names. The value of volume name can be either a specific volume or a  
nonspecific volume (scratch). If volume name is SCRATCH, EXPORT.n, or  
DUMP.n, you should mount a scratch volume. The value ‘n’ denotes the sequence  
number of the scratch volume being requested for DUMP DB or EXPORT  
operations.  
System Action: The server waits for the volume to be mounted.  
User Response: Mount the volume on an appropriate device in the specified  
library within the time limit. Use the REPLY command to communicate the device  
name to the server.  
Tivoli Storage Manager Messages  
885  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8303E  
I/O error on drive drive name (OP=internal code, SENSE=internal code).  
Explanation: An I/O error has occurred while operating on the designated drive.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive was  
identified correctly in the DEFINE DRIVE command, and that the device is  
currently powered on and ready. If the problem persists, contact your service  
representative and provide the internal code values from this message.  
ANR8303I (AS/400)  
Request number: device list  
Explanation: This message provides a list of devices that have the necessary  
attributes to satisfy the associated mount request.  
System Action: The server lists all of the devices defined in the given library.  
User Response: None.  
ANR8304E  
Time out error on drive drive name in library library name.  
Explanation: A time out condition occurred while waiting for the given drive to  
become ready so that automated library operations could be performed.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive was  
identified correctly in the DEFINE DRIVE command, and that the device is  
currently powered on and ready.  
ANR8304E (AS/400)  
Time-out error on drive drive name in library library name.  
Explanation: A time-out condition has occurred while waiting for the specified  
drive to become ready so that automated library operations can be performed.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive has  
been identified correctly in the DEFINE DRIVE command, and that the device is  
currently powered on and ready.  
ANR8305E  
Library library name is not ready or not operational.  
Explanation: The specified automated library device is either not ready or not in  
an operational state.  
System Action: Initialization of the library device fails.  
886  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the library is powered on and ready for automated  
operations. Further initialization attempts for the given library will usually be  
postponed until the next attempt is made to access the library for an automated  
operation. During server startup, however, initialization may be retried after a short  
waiting period.  
ANR8305E (AS/400)  
Command: Category already exists.  
Explanation: The category cannot be created because it already exists.  
System Action: The server does not process the command.  
User Response: None.  
ANR8306I  
Request number: Insert device type volume volume name mount mode into the slot  
with element number slot element of library library name within time limit</  
mv> minutes; issue ’REPLY’ along with the request ID when ready.  
Explanation: A CHECKIN LIBVOLUME or a LABEL LIBVOLUME command  
is in progress, and the specified volume is needed. The server expects the volume to  
be inserted into the slot with the specified element number of the given library  
within the time limit specified in the message. For the slot and element number  
diagram of your library, refer to the documentation provided with the current ptf  
level or refer to the Administrator’s Guide for your release and platform.  
System Action: The server waits until a REPLY command is issued, or until the  
time limit expires.  
User Response: Insert the volume into the slot and issue a REPLY command,  
along with the request ID, to tell the server that the volume has been inserted.  
ANR8306E (AS/400)  
Command: Device device name is not defined in library library name.  
Explanation: The designated device has not been defined in the given library.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different device name. If  
appropriate, use the DEFINE DRIVE command to place the device in the specified  
library before reissuing the command.  
Tivoli Storage Manager Messages  
887  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8307I  
Request number: Remove device type volume volume name from slot with element  
number slot name of library library name; issue ’REPLY’ along with the request  
ID when ready.  
Explanation: A CHECKOUT LIBVOLUME command has completed. You can  
remove the volume from the slot with the specified element number and store it  
outside the library. For the slot and element number diagram of your library, refer to  
the documentation provided with the current ptf level or refer to the Administrator’s  
Guide manual for your release and platform.  
System Action: The server waits until a REPLY command is issued.  
User Response: Remove the volume from the slot and store it in a safe place.  
Issue a REPLY command, along with the request ID, to tell the server that the  
volume has been removed. The volume can be returned to the library with the  
CHECKIN LIBVOLUME command.  
ANR8307E (AS/400)  
Command: Volume volume name cannot be mounted on device device name.  
Explanation: The attributes of the designated volume do not match the attributes  
of the specified device. The volume cannot be mounted on the device.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different device name.  
ANR8308I  
Request number: device type volume volume name is required for use in library  
library name; CHECKIN LIBVOLUME required within time limit minutes.  
Explanation: A mount request has been made for a volume that is defined in a  
storage pool, but which is currently checked out of the given library.  
System Action: The server waits until it detects that the volume has been checked  
into the library, or the time limit expires.  
User Response: Obtain the required volume, and insert it into the library by  
issuing a CHECKIN LIBVOLUME command. Use the SWAP=YES option of the  
CHECKIN LIBVOLUME command if the library is currently full; this process  
allows the server to select an appropriate volume to be swapped out in order to  
make room for the required volume.  
ANR8308E (AS/400)  
Request number: Incorrect volume inserted into library library name.  
Explanation: The user has inserted the wrong volume into the indicated library.  
System Action: The volume is ejected, and the server continues to wait for the  
requested volume to be inserted.  
888  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the requested volume is inserted properly into the  
designated library.  
ANR8309E  
Mount attempt failed - library library name is not defined.  
Explanation: An attempt has been made to mount a volume, but the attempt fails  
because the specified library is not defined.  
System Action: The operation fails.  
User Response: Ensure that the LIBRARY attribute of the device class associated  
with the mount operation identifies a defined library. If not, correct the value of the  
LIBRARY attribute, or define the specified library and retry the operation.  
ANR8309E (AS/400)  
Mount attempt failed - library library name is not defined.  
Explanation: An attempt has been made to mount a volume, but the attempt fails  
because the specified library is not defined.  
System Action: The operation fails.  
User Response: Ensure that the LIBRARY parameter of the device class  
associated with the mount operation identifies a defined library. If not, correct the  
value of the LIBRARY parameter or define the specified library.  
ANR8310E  
An I/O error occurred while accessing library library name.  
Explanation: An I/O error occurs while accessing the designated library.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the library is  
identified correctly in the DEFINE LIBRARY command, and that the library is  
currently powered on and ready. If the library has an access door, make sure it is  
closed. After checking and correcting these potential problems, retry the operation.  
ANR8310E (AS/400)  
An I/O error occurred while accessing library library name.  
Explanation: An I/O error occurs while accessing the designated library.  
System Action: The operation fails.  
User Response: Ensure that the MLD parameter associated with the library is  
identified correctly in the DEFINE LIBRARY command, and that the library is  
currently powered on and ready. If the library has an access door, make sure it is  
closed. After checking and correcting these potential problems, try the operation  
again.  
Tivoli Storage Manager Messages  
889  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8311E  
An I/O error occurred while accessing drive drive name for low-level operation  
operation, errno = drive errno.  
Explanation: An I/O error occurs while performing the operation on the specified  
drive.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive is  
identified correctly in the DEFINE DRIVE command, and that the drive is currently  
powered on and ready. After checking and correcting these potential problems, retry  
the operation.  
ANR8311E (AS/400)  
An I/O error occurred while accessing drive drive name.  
Explanation: An I/O error occurs while accessing the specified drive.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive is  
identified correctly in the DEFINE DRIVE command, and that the drive is currently  
powered on and ready. After checking and correcting these potential problems, try  
the operation again.  
ANR8312E  
Volume volume name could not be located in library library name.  
Explanation: The designated volume cannot be found at its expected location in  
the given library.  
System Action: The operation fails.  
User Response: Perform an AUDIT LIBRARY operation on the designated library,  
which forces the server to reevaluate its inventory information for volumes in the  
library.  
ANR8312E (AS/400)  
Volume volume name could not be located in library library name.  
Explanation: The designated volume cannot be found at its expected location in  
the specified library.  
System Action: The operation fails.  
User Response: Perform an AUDIT LIBRARY operation on the designated library,  
and force the server to reevaluate its inventory information for volumes in the  
library.  
890  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8313E  
Volume volume name is not present in library library name.  
Explanation: A mount request is made for the given volume in the specified  
library, but the volume is not currently checked into the library.  
System Action: The mount operation fails. If the volume is being mounted for  
storage pool I/O (as opposed to import/export I/O), its ACCESS attribute is changed  
to UNAVAILABLE to prevent further mount requests.  
User Response: Issue a CHECKIN LIBVOLUME command to return the volume  
into the library, and update the volumes ACCESS attribute to READONLY or  
READWRITE using the UPDATE VOLUME command. Retry the mount request.  
ANR8313E (AS/400)  
Volume volume name is not present in library library name.  
Explanation: A mount request is made for the given volume in the specified  
library, but the volume is not currently checked into the library.  
System Action: The mount operation fails. If the volume is being mounted for  
storage pool I/O (as opposed to import/export I/O), its ACCESS attribute is changed  
to UNAVAILABLE to prevent further mount requests.  
User Response: Issue a CHECKIN LIBVOLUME command to introduce the  
volume into the library, and then update the volume ACCESS attribute to  
READONLY or READWRITE by using the UPDATE VOLUME command.  
ANR8314E  
Library library name is full.  
Explanation: A library operation fails because all of the library’s storage locations  
are occupied.  
System Action: The operation fails.  
User Response: Issue a CHECKOUT LIBVOLUME command to make room in  
the library. Retry the library operation.  
ANR8314E (AS/400)  
Library library name is full.  
Explanation: An attempt has been made to add a volume to the library. The  
operation fails because all of the library’s storage locations are occupied.  
System Action: The operation fails.  
User Response: Issue a CHECKOUT LIBVOLUME command to make room in  
the library.  
Tivoli Storage Manager Messages  
891  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8315E  
Command: The device type of drive drive name is not supported in library type  
libraries.  
Explanation: Drives of the type identified in the command are not supported in  
the given type of library.  
System Action: The command is not processed.  
User Response: Determine whether the drive and library combination is supported  
by the installed level of the server. If so, contact your service representative.  
ANR8315E (AS/400)  
Command: The device type of drive drive name is not supported in library type  
libraries.  
Explanation: Drives of the type identified in the command are not supported in  
the given type of library.  
System Action: The server does not process the command.  
User Response: Use a supported type of drive.  
ANR8316E  
Selecting swap volume to be checked out of library library name.  
Explanation: A CHECKIN LIBVOL command was issued for a library that has  
no empty slots to hold the new cartridge. The SWAP=YES parameter was included  
in the command.  
System Action: A CHECKOUT LIBVOL command will be automatically be  
issued, specifying either a scratch volume or, if there are none, a volume with the  
lowest number of mounts.  
User Response: Use a supported type of drive. volume from the library and store  
it in a safe place. Issue a REPLY command to tell the server that the volume has  
been removed. The volume can be introduced back into the library with the  
CHECKIN LIBVOLUME command.  
ANR8316E (AS/400)  
Command: The drive drive name is NOT located in the Media Library Device  
associated with library library name.  
Explanation: The drive identified in the command is not located in the Media  
Library Device associated with the given library.  
System Action: The server does not process the command.  
User Response: Use a drive located in the Media Library Device.  
892  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8317I  
The volume in device type drive drive name must be manually ejected.  
Explanation: This device type does not automatically eject the volume when it is  
dismounted and requires that the volume be manually ejected from the drive.  
System Action: None.  
User Response: Physically eject the volume from the drive.  
ANR8317E (AS/400)  
Unable to open file filespec - insufficient authority.  
Explanation: An attempt has been made to open the specified file, but the attempt  
failed because the server does not have the authority necessary to access the file.  
This error may occur if the server does not have the proper authority to create the  
given member in the specified file.  
System Action: The operation fails.  
User Response: Obtain the necessary authority from the security officer or the file  
owner and try the operation again.  
ANR8318I  
Request number: Mount side side of device type volume volume name mount mode  
in drive drive name of library library name within time limit</ mv> minutes.  
Explanation: The server requires that the specified volume be mounted as  
requested. Since the volume is two-sided, this message specifies which side (A or  
B) is needed by the server for I/O operations.  
System Action: The server waits for the volume to be mounted.  
User Response: Mount the volume in the specified drive.  
ANR8318E (AS/400)  
Command: Device device name is not available in library library name.  
Explanation: The designated device is not available to carry out an attempted  
operation in the given library. The device can be unavailable for the following  
reasons. The device may already be in use by the server. The device may already be  
in use by another job or another system. The AS/400 status of the device may  
render it unavailable to the server. An additional message will have been issued by  
the server.  
System Action: The server does not process the command.  
User Response: If another device is available in the library, reissue the command  
using that device name. If there are idle volumes mounted in the library, use the  
DISMOUNT VOLUME command to free a device, and then reissue the command  
Tivoli Storage Manager Messages  
893  
Download from Www.Somanuals.com. All Manuals Search And Download.  
using that device name. If the MOUNTWAIT value of the device class permits it,  
wait until a device is available in the library, and then reissue the command using  
that device name.  
ANR8319I  
Request number: Insert device type volume volume name mount mode into library  
library name within time limit minute(s).  
Explanation: A CHECKIN LIBVOLUME command is in progress, and the  
specified volume is needed. The server expects the volume to be inserted into the  
library with the convenience I/O station mechanism.  
System Action: The server waits until the volume is in the library, or until the  
time limit expires.  
User Response: Insert the specified volume into the library. If the volume has  
already been inserted into the library, no user action is necessary.  
ANR8319I (AS/400)  
Request number: Insert device type volume volume name mount mode into library  
library name within time limit minutes.  
Explanation: A CHECKIN LIBVOLUME command is in progress, and the  
specified volume is needed. The server expects the volume to be inserted into the  
library with the convenience I/O station mechanism.  
System Action: The server waits until the volume is in the library, or until the  
time limit expires.  
User Response: Insert the volume into the library. If the volume has already been  
inserted into the library, no user action is necessary.  
ANR8320I  
Request number: Insert device type volume volume name mount mode in drive  
drive name of library library name within time limit minute(s); issue ’REPLY ’  
along with the request ID when ready.  
Explanation: A CHECKIN LIBVOLUME or a LABEL LIBVOLUME command  
is in progress, and the specified volume is needed. The server expects the volume to  
be inserted in the designated drive of the given library within the time limit  
specified in the message.  
System Action: The server waits until a REPLY command is issued, or until the  
time limit expires.  
User Response: Insert the volume into the drive, and then issue a REPLY  
command, along with the request ID, to tell the server that the volume has been  
inserted.  
894  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8320I (AS/400)  
Request number: Insert device type volume volume name mount mode in drive  
drive name of library library name within time limit minutes; Issue ’REPLY’  
when ready.  
Explanation: A CHECKIN LIBVOLUME command is in progress, and the  
specified volume is needed. The server expects the volume to be inserted in the  
designated drive of the given library within the time limit specified in the message.  
System Action: The server waits until a REPLY command is issued, or until the  
time limit expires.  
User Response: Insert the volume into the drive, and then issue a REPLY  
command to tell the server that the volume has been inserted.  
ANR8321I  
Request number: Remove device type volume volume name from drive drive name  
of library library name; issue ’REPLY’ along with the request ID when ready.  
Explanation: A CHECKOUT LIBVOLUME or a LABEL LIBVOLUME  
command has completed. You can remove the specified volume from the designated  
drive and store it outside the library.  
System Action: The server waits until a REPLY command is issued.  
User Response: Remove the volume from the drive and store it in a safe place.  
Issue a REPLY command, along with the request ID, to tell the server that the  
volume has been removed. The volume can be returned to the library with the  
CHECKIN LIBVOLUME command.  
ANR8321I (AS/400)  
Request number: Remove device type volume volume name from drive drive name  
of library library name; Issue ’REPLY’ when ready.  
Explanation: A CHECKOUT LIBVOLUME command has completed. You can  
remove the specified volume from the designated drive and store it outside the  
library.  
System Action: The server waits until a REPLY command is issued.  
User Response: Remove the volume from the drive and store it in a safe place.  
Then issue a REPLY command to tell the server that the volume has been removed.  
The volume can be checked back into the library with the CHECKIN LIBVOLUME  
command.  
Tivoli Storage Manager Messages  
895  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8322I  
Request number: Remove device type volume volume name from entry/exit port  
of library library name; issue ’REPLY’ along with the request ID when ready.  
Explanation: A CHECKOUT LIBVOLUME command has completed. You can  
remove the specified volume from the entry/exit port of the given library and store  
it elsewhere.  
System Action: The server waits until a REPLY command is issued.  
User Response: Remove the volume from the library and store it in a safe place.  
Issue a REPLY command, along with the request ID, to tell the server that the  
volume has been removed. The volume can be returned to the library with the  
CHECKIN LIBVOLUME command.  
ANR8322I (AS/400)  
Request number: Remove device type volume volume name from entry/exit port  
of library library name; Issue ’REPLY’ when ready.  
Explanation: A CHECKOUT LIBVOLUME command has completed. You can  
remove the specified volume from the entry/exit port of the given library and store  
it elsewhere.  
System Action: The server waits until a REPLY command is issued.  
User Response: Remove the volume from the library and store it in a safe place.  
Then issue a REPLY command to tell the server that the volume has been removed.  
The volume can be checked back into the library with the CHECKIN LIBVOLUME  
command.  
ANR8323I  
Request number: Insert device type volume volume name mount mode into  
entry/exit port of library library name within time limit minute(s); issue  
’REPLY’ along with t he request ID when ready.  
Explanation: A CHECKIN LIBVOLUME or a LABEL LIBVOLUME cmmand is  
in progress, and the specified volume is needed. Mount the volume in the entry/exit  
port of the given library within the time limit specified in the message.  
System Action: The server waits until a REPLY command is issued, or until the  
time limit expires.  
User Response: Insert the volume into the library’s entry/exit port; and issue a  
REPLY command, along with the request ID, to tell the server that the volume has  
been inserted.  
896  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8323I (AS/400)  
Request number: Insert device type volume volume name mount mode into  
entry/exit port of library library name within time limit minutes; Issue ’REPLY’  
when ready.  
Explanation: A CHECKIN LIBVOLUME command is in progress, and the  
specified volume is needed. Mount the volume in the entry/exit port of the given  
library within the time limit specified in the message.  
System Action: The server waits until a REPLY command is issued, or until the  
time limit expires.  
User Response: Insert the volume into the library’s entry/exit port, and then issue  
a REPLY command to tell the server that the volume has been inserted.  
ANR8324I  
Device type volume volume name is expected to be mounted (mount mode).  
Explanation: The specified volume is expected to be mounted in the near future  
so the server can access it for reading or writing.  
System Action: None.  
User Response: If the volume is stored offline, retrieve it so that it is readily  
accessible when the server requests that it be mounted.  
ANR8324I (AS/400)  
Device type volume volume name is expected to be mounted (mount mode).  
Explanation: The specified volume is expected to be mounted in the near future  
so that the server can access it for reading or writing.  
System Action: None.  
User Response: If the volume is stored offline, retrieve it so that it is readily  
accessible when the server requests that it be mounted.  
ANR8325I  
Dismounting volume volume name - mount retention period minute mount  
retention expired.  
Explanation: The specified volume is dismounted because the given mount  
retention period has expired.  
System Action: The volume is dismounted.  
User Response: None.  
Tivoli Storage Manager Messages  
897  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8325I (AS/400)  
Dismounting volume volume name - mount retention period minute mount  
retention expired.  
Explanation: The specified volume is dismounted because the given mount  
retention period has expired.  
System Action: The volume is dismounted.  
User Response: None.  
ANR8326I  
Request number: Mount device type volume volume name mount mode in drive  
drive name of library library name within time limit minutes.  
Explanation: If the volume name includes the names EXP, IMP, DUMP, or  
DBBK, the request is for a scratch volume.  
System Action: The server waits for the volume to be mounted.  
User Response: Mount the volume in the specified drive.  
ANR8326I (AS/400)  
Request number: Mount device type volume volume name mount mode in drive  
drive name of library library name within time limit minutes.  
Explanation: The server requires that the specified volume be mounted as  
requested. The value of volume name can be either a specific volume or a  
nonspecific volume (scratch). If volume name is SCRATCH, EXPORT.n, or  
DUMP.n, you should mount a scratch volume. The value ’n’ denotes the sequence  
number of the scratch volume being requested for DUMP DB or EXPORT  
operations.  
System Action: The server waits for the volume to be mounted.  
User Response: Mount the volume in the specified drive within the time limit. If  
this is a request for a SCRATCH mount, use the REPLY command to indicate to the  
server that a volume has been mounted.  
ANR8327E  
Command: Cannot cancel request request number.  
Explanation: The request, whose number is specified by the given command,  
cannot be canceled. The requested operation must be completed.  
System Action: The cancel request command is not processed.  
User Response: Proceed with the requested operation.  
898  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8327E (AS/400)  
Command: Cannot cancel request request number.  
Explanation: The request, whose number is specified by the given command,  
cannot be canceled. The requested operation must be completed.  
System Action: The CANCEL REQUEST command is not processed.  
User Response: Proceed with the requested operation.  
ANR8328I  
Request number: device type volume volume name mounted in drive drive name.  
Explanation: The server verifies that a requested volume has been mounted  
properly in the given drive.  
System Action: The volume is accessed for reading or writing, or both.  
User Response: None.  
ANR8328I (AS/400)  
Request number: device type volume volume name mounted in drive drive name.  
Explanation: The server verifies that a requested volume has been mounted  
properly in the given drive.  
System Action: The volume can be accessed for reading or writing, or both.  
User Response: None.  
ANR8329I  
Device type volume volume name is mounted mount mode in drive drive name,  
status: IDLE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted in the specified drive. The volume is currently  
idle, meaning no active operations are being performed. If the volume remains in  
the idle state for the amount of time specified by the device class mount retention  
period, it will be automatically dismounted.  
System Action: None.  
User Response: None.  
ANR8329I (AS/400)  
Device type volume volume name is mounted mount mode in drive drive name,  
status: IDLE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted in the specified drive. The volume is currently  
Tivoli Storage Manager Messages  
899  
Download from Www.Somanuals.com. All Manuals Search And Download.  
idle, that is, no active operations are being performed. If the volume remains in the  
idle state for the amount of time specified by the device class mount retention  
period, it is automatically dismounted.  
System Action: None.  
User Response: None.  
ANR8330I  
Device type volume volume name is mounted mount mode in drive drive name,  
status: IN USE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted in the specified drive. The volume is currently in  
use, meaning that read or write operations, or both, are being performed.  
System Action: None.  
User Response: None.  
ANR8330I (AS/400)  
Device type volume volume name is mounted mount mode in drive drive name,  
status: IN USE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted in the specified drive. The volume is currently in  
use, meaning that read or write operations, or both, are being performed.  
System Action: None.  
User Response: None.  
ANR8331I  
Device type volume volume name is mounted mount mode in drive drive name,  
status: DISMOUNTING.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted in the specified drive. The volume is currently  
being dismounted by the server.  
System Action: None.  
User Response: None.  
ANR8331I (AS/400)  
Device type volume volume name is mounted mount mode in drive drive name,  
status: DISMOUNTING.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted in the specified drive. The volume is currently  
being dismounted by the server.  
900  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: None.  
ANR8332I  
Device type volume volume name is mounted mount mode, status: IDLE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently idle,  
meaning no active operations are being performed. If the volume remains in the idle  
state for the amount of time specified by the device class mount retention period, it  
will be automatically dismounted.  
System Action: None.  
User Response: None.  
ANR8332I (AS/400)  
Device type volume volume name is mounted mount mode, status: IDLE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently idle,  
that is, no active operations are being performed. If the volume remains in the idle  
state for the amount of time specified by the device class mount retention period, it  
is automatically dismounted.  
System Action: None.  
User Response: None.  
ANR8333I  
Device type volume volume name is mounted mount mode, status: IN USE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently in use,  
meaning that read or write operations, or both are being performed.  
System Action: None.  
User Response: None.  
ANR8333I (AS/400)  
Device type volume volume name is mounted mount mode, status: IN USE.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently in use,  
meaning that read or write operations, or both are being performed.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
901  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8334I  
Number of volumes volumes found.  
Explanation: This is a summary message for the QUERY MOUNT command. It  
indicates the total number of mounted volumes that have been reported in the  
command output.  
System Action: None.  
User Response: None.  
ANR8334I (AS/400)  
Number of volumes volumes found.  
Explanation: This is a summary message for the QUERY MOUNT command. It  
indicates the total number of mounted volumes that have been reported in the  
command output.  
System Action: None.  
User Response: None.  
ANR8335I  
Request number: Verifying label of device type volume volume name in drive drive  
name.  
Explanation: The server verifies the label of the volume that has been requested  
by an earlier mount message. This is done to ensure that the correct volume has  
been mounted by the operator.  
System Action: The server reads the volume label and checks it for validity.  
User Response: None.  
ANR8335I (AS/400)  
Request number: Verifying label of device type volume volume name in drive drive  
name.  
Explanation: The server verifies the label of the volume that has been requested  
by an earlier mount message. This is done to ensure that the correct volume has  
been mounted by the operator.  
System Action: The server reads the volume label and checks it for validity.  
User Response: None.  
ANR8336I  
Verifying label of device type volume volume name in drive drive name.  
Explanation: The server verifies the label of a volume that is needed for read or  
write operations, or both. This is done to ensure that the correct volume has been  
mounted.  
902  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server reads the volume label and checks it for validity.  
User Response: None.  
ANR8336I (AS/400)  
Verifying label of device type volume volume name in drive drive name.  
Explanation: The server verifies the label of a volume that is needed for read or  
write operations, or both. This is done to ensure that the correct volume has been  
mounted.  
System Action: The server reads the volume label and checks it for validity.  
User Response: None.  
ANR8337I  
Request number volume volume name mounted in drive drive name.  
Explanation: The server verifies that the specified mount request has been  
completed properly. Read or write operations, or both, can be performed on the  
volume.  
System Action: The label of the volume has been verified.  
User Response: None.  
ANR8337I (AS/400)  
Request number volume volume name mounted in drive drive name.  
Explanation: The server verifies that the specified mount request has been  
completed properly. Read or write operations, or both, can be performed on the  
volume.  
System Action: The label of the volume has been verified.  
User Response: None.  
ANR8338E  
Device type volume volume name cannot be overwritten by EXPORT operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new export data to be written to it.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested export operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the export operation.  
Tivoli Storage Manager Messages  
903  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8338E (AS/400)  
Device type volume volume name cannot be overwritten by operation operation.  
Explanation: The specified volume already exists or contains data so that the  
server cannot allow new data to be written to it.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and try the given operation again.  
ANR8339E  
Device type volume intended volume name in drive drive name was replaced with  
volume incorrect volume name.  
Explanation: The server detects that a previously mounted and verified volume  
(the desired volume) has been replaced with a different volume (the incorrect  
volume). No further read or write operations, or both, can occur on the given drive,  
because data corruption may occur.  
System Action: The server dismounts the volume from the drive.  
User Response: Mount the correct volume again if it is in a manual library and  
retry the operation.  
ANR8339E (AS/400)  
Device type volume intended volume name in drive drive name was replaced with  
volume incorrect volume name.  
Explanation: The server detects that a previously mounted and verified volume  
(the intended volume) has been replaced with a different volume (the incorrect  
volume). No further read or write operations, or both, can occur on the given drive  
because data corruption may occur.  
System Action: The server dismounts the volume from the drive.  
User Response: None.  
ANR8340I  
Device type volume volume name mounted.  
Explanation: The server has mounted the given volume.  
System Action: Read or write operations, or both, will commence for the volume.  
User Response: None.  
904  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8340I (AS/400)  
Device type volume volume name mounted.  
Explanation: The server has mounted the given volume.  
System Action: Read or write operations, or both, will commence for the volume.  
User Response: None.  
ANR8341I  
End-of-volume reached for device type volume volume name.  
Explanation: The server has detected an end-of-volume condition for the given  
volume.  
System Action: The volume is marked full. If more data must be stored, the server  
will access another volume for it.  
User Response: None.  
ANR8341I (AS/400)  
End-of-volume reached for device type volume volume name.  
Explanation: The server has detected an end-of-volume condition for the given  
volume.  
System Action: The volume is marked full. If more data must be stored, the server  
will access another volume to store it.  
User Response: None.  
ANR8342I  
Request request number for volume volume name canceled by administrator name.  
Explanation: A mount request is canceled by the given administrator.  
System Action: The system cancels the mount request.  
User Response: None.  
ANR8342I (AS/400)  
Request request number for volume volume name canceled by administrator name.  
Explanation: A mount request is canceled by the given administrator.  
System Action: The system cancels the mount request.  
User Response: None.  
Tivoli Storage Manager Messages  
905  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8343I  
Request request number for volume volume name canceled (PERMANENT) by  
administrator name.  
Explanation: A mount request is successfully canceled with the PERMANENT  
option.  
System Action: The system cancels the mount request and marks the volume as  
unavailable.  
User Response: None.  
ANR8343I (AS/400)  
Request request number for volume volume name canceled (PERMANENT) by  
administrator name.  
Explanation: A mount request is successfully canceled with the PERMANENT  
option by the given administrator.  
System Action: The system cancels the mount request and marks the volume as  
unavailable.  
User Response: None.  
ANR8344E  
Command: Invalid request number - request number.  
Explanation: A command has been entered with an incorrect request number.  
System Action: The server does not process the command.  
User Response: Issue the command with the correct request number.  
ANR8344E (AS/400)  
Command: Invalid request number - request number.  
Explanation: A command has been entered with an incorrect request number.  
System Action: The server does not process the command.  
User Response: Issue the command with the correct request number.  
ANR8345E  
Command: No match found for this request number.  
Explanation: The request number specified by the command is not in the list of  
outstanding mount requests.  
System Action: The server does not process the command.  
User Response: Issue the command with the correct request number.  
906  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8345E (AS/400)  
Command: No match found for this request number.  
Explanation: The request number specified by the command is not in the list of  
outstanding mount requests.  
System Action: The server does not process the command.  
User Response: Issue the command with the correct request number.  
ANR8346I  
Command: No requests are outstanding.  
Explanation: A QUERY REQUEST or CANCEL REQUEST command has been  
entered although no mount requests are outstanding.  
System Action: Server operation continues.  
User Response: None.  
ANR8346I (AS/400)  
Command: No requests are outstanding.  
Explanation: A QUERY REQUEST or CANCEL REQUEST command has been  
entered although no mount requests are outstanding.  
System Action: Server operation continues.  
User Response: None.  
ANR8347E  
Command: Volume volume not found.  
Explanation: A DISMOUNT VOLUME command is issued, but the volume to be  
dismounted cannot be found.  
System Action: Server operation continues.  
User Response: Ensure that the correct volume name is entered.  
ANR8347E (AS/400)  
Command: Volume volume not found.  
Explanation: A DISMOUNT VOLUME command is issued, but the volume to be  
dismounted cannot be found.  
System Action: Server operation continues.  
User Response: Ensure that the correct volume name is entered.  
Tivoli Storage Manager Messages  
907  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8348E  
Command: Volume volume is not Idle.  
Explanation: A DISMOUNT VOLUME command has been issued, but the  
volume is still in use and cannot be dismounted.  
System Action: Server operation continues.  
User Response: If it is necessary to dismount the volume, cancel the session or  
process that is using the volume, and reissue the command.  
ANR8348E (AS/400)  
Command: Volume volume is not Idle.  
Explanation: A DISMOUNT VOLUME command has been issued, but the  
volume is in use and cannot be dismounted.  
System Action: Server operation continues.  
User Response: If it is necessary to dismount the volume, cancel the session or  
process that is using the volume, and reissue the DISMOUNT VOLUME command.  
ANR8349E  
Command: Device device not found.  
Explanation: A DISMOUNT DEVICE command has been issued, but the device  
to be dismounted cannot be found.  
System Action: Server operation continues.  
User Response: Ensure that the correct device has been specified.  
ANR8349E (AS/400)  
Command: Cannot reply to request request number.  
Explanation: The state of the request, whose number is specified by the given  
command, does not permit the use of the REPLY command.  
System Action: The REPLY command is not processed.  
User Response: The REPLY command is invalid for the current state of the  
specified request. The outstanding request must be satisfied by using your  
installation’s procedures.  
ANR8350E  
Command: Device device is not Idle.  
Explanation: A DISMOUNT DEVICE command has been issued, but the device  
is still in use and cannot be dismounted.  
System Action: Server operation continues.  
908  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If it is necessary to dismount the device, cancel the session or  
process that is using the device, and reissue the command.  
ANR8350E (AS/400)  
Command: Device device is not Idle.  
Explanation: A DISMOUNT DEVICE command has been issued, but the device  
is in use and cannot be dismounted.  
System Action: Server operation continues.  
User Response: If it is necessary to dismount the device, cancel the session or  
process that is using the device, and reissue the DISMOUNT DEVICE command.  
ANR8351E  
Request number: Mount request for volume volume name has timed out.  
Explanation: The mount request has not been satisfied in the requested time.  
System Action: The server fails the mount request.  
User Response: Retry the mount request and ensure that the volume is mounted  
within the time limit for the manual library. For an automated library, retry the  
mount request and increase the mount wait time for the device class.  
ANR8351E (AS/400)  
Request number: Mount request for volume volume name has timed out.  
Explanation: The mount request has not been performed in the requested time.  
System Action: The server fails the mount request.  
User Response: None.  
ANR8352I  
Requests outstanding:  
Explanation: This message provides a list of currently outstanding mount requests.  
System Action: The server lists all outstanding mount requests or the one specified  
on the QUERY REQUEST command.  
User Response: None.  
ANR8352I (AS/400)  
Requests outstanding:  
Explanation: This message provides a list of currently outstanding mount requests.  
System Action: The server lists all outstanding mount requests or the one specified  
on the QUERY REQUEST command.  
Tivoli Storage Manager Messages  
909  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR8353E  
Request number: I/O error reading label of volume in drive drive name.  
Explanation: The server detects an error while reading the volume label from the  
volume in the specified drive.  
System Action: The volume is ejected, and the server continues to wait for the  
requested volume to be mounted.  
User Response: Ensure the following:  
The requested volume is properly inserted in the designated drive.  
The volume has been labeled by using the DSMLABEL utility program before  
you attempt to use it with the server.  
The DEVICE parameter associated with the drive is identified correctly in the  
DEFINE DRIVE command, and the drive is currently powered on and ready.  
After checking and correcting these potential problems, retry the operation.  
ANR8353E (AS/400)  
Request number: I/O error reading label of volume in drive drive name.  
Explanation: ADSM detects an I/O error while reading the volume label from the  
volume in the specified drive.  
System Action: If a volume was mounted, it is ejected. If the library is of type  
USRDFN, this media operation fails. For any other library type, the server continues  
to wait for the requested volume to be mounted.  
User Response: Ensure that the requested volume is inserted properly in the  
designated drive. Also, make sure that the volume has been labeled by using the  
INZTAP command before you attempt to use it with the server.  
ANR8354E  
Request number: Incorrect volume (volume name) mounted in drive drive name.  
Explanation: The user has inserted the named volume into the indicated drive, but  
it is not the one requested by the server.  
System Action: The volume is ejected, and the server continues to wait for the  
requested volume to be mounted.  
User Response: Ensure that the requested volume is inserted properly into the  
designated drive.  
ANR8354E (AS/400)  
Request number: Incorrect volume (volume name) mounted in drive drive name.  
Explanation: The user has inserted the specified volume into the indicated drive,  
but it is not the one requested by the server.  
910  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: If a volume was mounted, it is ejected. If the library is of type  
USRDFN, this media operation fails. For any other library type, the server continues  
to wait for the requested volume to be mounted.  
User Response: Ensure that the requested volume is inserted properly into the  
designated drive.  
ANR8355E  
I/O error reading label for volume volume name in drive drive name.  
Explanation: The server detects an error while reading/verifying the volume label  
for the volume in the specified drive.  
System Action: The volume is dismounted by the server.  
User Response: Ensure the following:  
Check the integrity of the data on the volume by issuing an AUDIT VOLUME  
command. If this error occurs on a volume that is stored inside a SCSI library,  
the library itself may need to be audited by using the AUDIT LIBRARY  
command.  
The DEVICE parameter associated with the drive is identified correctly in the  
DEFINE DRIVE command, and the drive is currently powered on and ready.  
After checking and correcting these potential problems, retry the operation.  
ANR8355E (AS/400)  
I/O error reading label for volume volume name in drive drive name.  
Explanation: ADSM detects an error while reading or verifying the volume label  
for the volume in the specified drive.  
System Action: If a volume was mounted, it is ejected. If the library is of type  
USRDFN, this media operation fails. For any other library type, the server continues  
to wait for the requested volume to be mounted.  
User Response: Check the integrity of the data on the volume by issuing an  
AUDIT VOLUME command.  
ANR8356E  
Incorrect volume mounted volume name was mounted instead of volume expected  
volume name in library library name.  
Explanation: The incorrect volume has been mounted in the designated library.  
This error can occur if the library inventory has been altered due to manual  
intervention or movement of volumes, or both.  
System Action: The volume is dismounted; the expected volume may be marked  
unavailable if this error occurs during normal volume mount activity.  
Tivoli Storage Manager Messages  
911  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the AUDIT LIBRARY command to force the library to  
reevaluate its inventory of volumes.  
ANR8356E (AS/400)  
Incorrect volume mounted volume name was mounted instead of volume expected  
volume name in library library name.  
Explanation: The incorrect volume was mounted in the designated library. This  
error can occur if the library inventory has been altered due to manual intervention  
or movement of volumes, or both.  
System Action: The volume is dismounted. The expected volume may be marked  
unavailable if this error occurs during normal volume mount activity.  
User Response: Use the AUDIT LIBRARY command to force the library to  
reevaluate its inventory of volumes.  
ANR8357I  
Error reading label of volume from slot-element element address in drive drive  
name of library library name.  
Explanation: While processing a search-mode CHECKIN LIBVOLUME  
command for the designated library, the server finds a volume whose label cannot  
be read.  
System Action: The volume is dismounted and is not checked into the library.  
User Response: Remove the volume from the library and ensure that it is properly  
labeled. After doing so, the volume can be checked into the library.  
ANR8357E (AS/400)  
Error reading label of volume in drive drive name of library library name.  
Explanation: While processing a search-mode CHECKIN LIBVOLUME  
command for the designated library, the server finds a volume whose label cannot  
be read.  
System Action: The volume is dismounted and is not checked into the library.  
User Response: Remove the volume from the library and ensure that it is properly  
labeled. Then check the volume back into the library.  
ANR8358E  
Audit operation is required for library library name.  
Explanation: The server encounters a problem managing the given library, and  
determines that an AUDIT LIBRARY operation should be performed.  
System Action: The server may continue to access the library, but some volumes  
may not be accessible until an AUDIT LIBRARY command is issued against the  
library.  
912  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Issue an AUDIT LIBRARY command against the library.  
ANR8358E (AS/400)  
Audit operation is required for library library name.  
Explanation: The server encounters a problem managing the given library, and  
determines that an AUDIT LIBRARY operation should be performed.  
System Action: The server may continue to access the library, but some volumes  
may not be accessible until an AUDIT LIBRARY command is issued against the  
library.  
User Response: Issue an AUDIT LIBRARY command against the library to verify  
the library’s inventory.  
ANR8359E  
Media fault detected on device type volume volume name in drive drive name of  
library library name.  
Explanation: The server encounters a media fault while accessing the given  
volume using the specified drive.  
System Action: The operation that is attempting to access the volume will fail,  
and the volume will be immediately dismounted from the drive.  
User Response: In some cases, the server will automatically mark the volume  
unavailable. If this does not happen automatically, issue an UPDATE VOLUME  
command to set the volume’s access value to unavailable. This will prevent the  
server from trying to mount the volume to satisfy user requests. Issue an AUDIT  
VOLUME command to determine if any data has been lost due to the media failure.  
ANR8359E (AS/400)  
Media fault detected on device type volume volume name in drive drive name of  
library library name.  
Explanation: The server encounters a media fault while accessing the given  
volume using the specified drive.  
System Action: The operation that is attempting to access the volume fails, and  
the volume is immediately dismounted from the drive.  
User Response: In some cases, the server automatically marks the volume  
unavailable. If this does not happen automatically, issue an UPDATE VOLUME  
command to set the volume’s access value to unavailable. This prevents the server  
from trying to mount the volume to satisfy user requests. It is also necessary to  
issue an AUDIT VOLUME command to determine if any data has been lost due to  
the media failure.  
Tivoli Storage Manager Messages  
913  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8360I  
Volume volume name has been deleted from MANUAL library library name.  
Explanation: The specified volume has been deleted by the server. It can be  
returned to a scratch pool by the mount operator if desired.  
System Action: The volume is removed from the server’s inventory.  
User Response: None.  
ANR8360I (AS/400)  
Volume volume name has been deleted from library type library library name.  
Explanation: The specified volume has been deleted by the server. It can be  
returned to a scratch pool by the mount operator if desired.  
System Action: The volume is removed from the server’s inventory.  
User Response: No action is required.  
ANR8361E  
Command: Device type not specified.  
Explanation: The specified command requires that the DEVTYPE parameter be  
supplied.  
System Action: The command is not processed.  
User Response: Reissue the command, and specify a valid DEVTYPE parameter.  
ANR8361E (AS/400)  
Command: Device type not specified.  
Explanation: The specified command requires that the DEVTYPE parameter be  
supplied.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a valid DEVTYPE parameter.  
ANR8362E  
Command: The parameter parameter is invalid for device type device type.  
Explanation: The specified parameter is not valid for a device class with the given  
device type.  
System Action: The command is not processed.  
User Response: Reissue the command with a correct parameter.  
914  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8362E (AS/400)  
Command: The parameter parameter is invalid for device type device type.  
Explanation: The specified parameter is not valid for a device class with the given  
device type.  
System Action: The server does not process the command.  
User Response: Reissue the command with a correct parameter.  
ANR8363E  
Command: The parameter parameter is required for device type device type.  
Explanation: The specified command requires that the given parameter be  
supplied when the indicated device type is used.  
System Action: The command is not processed.  
User Response: Reissue the command, providing the required parameter value.  
ANR8363E (AS/400)  
Command: The parameter parameter is required for device type device type.  
Explanation: The specified command requires that the given parameter be  
supplied when the indicated device type is used.  
System Action: The server does not process the command.  
User Response: Reissue the command and provide the required parameter value.  
ANR8364E  
Command: Cannot reduce MOUNTLIMIT below number of volumes currently  
mounted.  
Explanation: The MOUNTLIMIT value cannot be reduced below the number of  
currently mounted volumes.  
System Action: The command is not processed.  
User Response: Wait until the server finishes using some of the mounted volumes,  
or force the server to dismount idle volumes using the DISMOUNT VOLUME  
command, then retry this command.  
ANR8364E (AS/400)  
Command: Cannot reduce MOUNTLIMIT below number of volumes currently  
mounted.  
Explanation: The MOUNTLIMIT value cannot be reduced below the number of  
currently mounted volumes.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Wait until the server finishes using some of the mounted volumes,  
or force the server to dismount idle volumes using the DISMOUNT VOLUME  
command. Then reissue this command.  
ANR8365E  
Command: The parameter parameter cannot be changed.  
Explanation: The specified parameter cannot be changed from the value that was  
provided with the associated DEFINE command.  
System Action: The command is not processed.  
User Response: If it is necessary to use a different value for the given parameter,  
the associated object must be deleted and then redefined using the new parameter  
value.  
ANR8365E (AS/400)  
Command: The parameter parameter cannot be changed.  
Explanation: The specified parameter cannot be changed from the value that was  
provided with the associated DEFINE command.  
System Action: The server does not process the command.  
User Response: To use a different value for the given parameter, the associated  
object must be deleted and then defined by using the new parameter value.  
ANR8366E  
Command: Invalid value for parameter parameter.  
Explanation: An invalid value has been provided for the specified parameter.  
System Action: The command is not processed.  
User Response: Reissue the command, and specify a valid parameter value.  
ANR8366E (AS/400)  
Command: Invalid value for parameter parameter.  
Explanation: An invalid value has been provided for the specified parameter.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a valid parameter value.  
ANR8367E  
Command: Multiple parameter values are not allowed.  
Explanation: The designated parameter is specified more than once in the  
command; this is not allowed.  
System Action: The command is not processed.  
916  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command, but specify the given parameter only once.  
ANR8367E (AS/400)  
Command: Multiple parameter values are not allowed.  
Explanation: The designated parameter is specified more than once in the  
command, which is not allowed.  
System Action: The server does not process the command.  
User Response: Reissue the command, but specify the given parameter only once.  
ANR8368E  
Request number: Incorrect side (side) of volume volume name mounted in drive  
drive name.  
Explanation: The user inserted the wrong side of the requested volume into the  
indicated drive.  
System Action: The volume is ejected, and the server continues to wait for the  
requested side of the volume to be mounted.  
User Response: Insert the correct side of the requested volume into the designated  
drive.  
ANR8368E (AS/400)  
Request number: Incorrect side (side) of volume volume name mounted in drive  
drive name.  
Explanation: The user has inserted the wrong side of the requested volume into  
the indicated drive.  
System Action: The volume is ejected, and the server continues to wait for the  
requested side of the volume to be mounted.  
User Response: Insert the correct side of the requested volume into the designated  
drive.  
ANR8369E  
Library library name is not defined.  
Explanation: The designated library is not defined, but has been referenced in a  
mount request.  
System Action: The mount request is rejected.  
User Response: Define the given library, or update the LIBRARY parameter of the  
device class that references it.  
Tivoli Storage Manager Messages  
917  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8369E (AS/400)  
Library library name is not defined.  
Explanation: The designated library is not defined, but has been referenced in a  
mount request.  
System Action: The mount request is rejected.  
User Response: Define the given library or update the LIBRARY parameter of the  
device class that references it.  
ANR8370I  
Device type volume volume name is mounted mount mode, status: RETRY.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently in  
RETRY, meaning an attempt is being made to re-establish communications with  
another server. If the volume remains in the retry state for the amount of time  
specified by the device class retry period, the operation will fail and the volume will  
be automatically dismounted.  
System Action: None.  
User Response: None.  
ANR8370I (AS/400)  
Device type volume volume name is mounted mount mode, status: RETRY.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently in  
RETRY, meaning an attempt is being made to re-establish communications with  
another server. If the volume remains in the retry state for the amount of time  
specified by the device class retry period, the operation will fail and the volume will  
be automatically dismounted.  
System Action: None.  
User Response: None.  
ANR8371I  
I/O is being bypassed for volume volume name.  
Explanation: The indicated volume is mounted but the server is bypassing actual  
I/O operations for the volume. The pool associated with the volume matches the  
NULLPOOLNAME option in the options file or NULLFILEDEVCLASS YES has  
been specified in the options file.  
System Action: None.  
User Response: None.  
918  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8372I  
Request number: Remove device type volume volume name from drive drive name  
of library library name.  
Explanation: A LABEL LIBVOLUME command has completed. You can remove  
the specified volume from the designated drive and store it outside the library.  
System Action: None.  
User Response: Remove the volume from the drive and store it in a safe place.  
ANR8373I  
Request number: Fill the bulk entry/exit port of library library name with all  
device type volumes to be processed within time limit minute(s); issue ’REPLY’  
along with the request ID when ready.  
Explanation: A CHECKIN LIBVOLUME or LABEL LIBVOL command with  
SEARCH=BULK is in progress. Load all volumes to be processed into the  
multi-slot entry/exit port of the given library within the time limit specified in the  
message.  
System Action: The server waits until a REPLY command is issued, or until the  
time limit expires.  
User Response: Insert the volumes into the library’s entry/exit port; and issue a  
REPLY command, along with the request ID, to tell the server that the volumes  
have been inserted.  
ANR8374E  
Unable to unmount mountpoint mountpoint name.  
Explanation: A removable file device class mountpoint had to be unmounted  
using the operating system unmount function. The server did not have permission to  
unmount the directory specified.  
System Action: The server continues, but cannot use the mountpoint for  
removablefile support until the directory is unmounted.  
User Response: It may be necessary to run the server as a root user to mounted  
directories to be unmounted.  
ANR8375E  
Device type volume volume name cannot be overwritten by BACKUPSET  
operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new backup set data to be written to it.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested backup set operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the backup set operation.  
Tivoli Storage Manager Messages  
919  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8400I  
Library library name defined.  
Explanation: The designated library has been successfully defined.  
System Action: The library is defined and recorded in the database.  
User Response: None.  
ANR8400I (AS/400)  
Library library name defined.  
Explanation: The designated library has been successfully defined.  
System Action: The library is defined and recorded in the database.  
User Response: None.  
ANR8401E  
Command: Invalid library name library name.  
Explanation: The designated library name is invalid; either it contains too many  
characters, or some of the characters are invalid.  
System Action: The command is not processed.  
User Response: Reissue the command using a valid library name.  
ANR8401E (AS/400)  
Command: Invalid library name library name.  
Explanation: The designated library name is invalid; either it contains too many  
characters, or some of the characters are invalid.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a valid library name.  
ANR8402E  
Command: Library library name is already defined.  
Explanation: The designated library cannot be defined because it already exists.  
System Action: The command is not processed.  
User Response: If you want to define an additional library, reissue the command  
with a different library name.  
920  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8402E (AS/400)  
Command: Library library name is already defined.  
Explanation: The designated library cannot be defined because it already exists.  
System Action: The server does not process the command.  
User Response: None.  
ANR8403E  
Command: Operation not allowed for library type libraries.  
Explanation: The requested operation is not allowed for libraries of the given  
type.  
System Action: The command is not processed.  
User Response: None.  
ANR8403E (AS/400)  
Command: Operation not allowed for library type libraries.  
Explanation: The requested operation is not allowed for libraries of the given  
type.  
System Action: The server does not process the command.  
User Response: None.  
ANR8404I  
Drive Drive name defined in library library name.  
Explanation: The designated drive has been successfully defined as a member of  
the specified library.  
System Action: The drive is defined and recorded in the database.  
User Response: None.  
ANR8404I (AS/400)  
Drive Drive name defined in library library name.  
Explanation: The designated drive has been successfully defined as a member of  
the specified library.  
System Action: The drive is defined and recorded in the database.  
User Response: None.  
Tivoli Storage Manager Messages  
921  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8405E  
Command: Invalid drive name drive name.  
Explanation: The designated drive name is invalid; either it contains too many  
characters, or some of the characters are invalid.  
System Action: The command is not processed.  
User Response: Reissue the command using a valid drive name.  
ANR8405E (AS/400)  
Command: Invalid drive name drive name.  
Explanation: The designated drive name is invalid because it contains too many  
characters or some of the characters are invalid.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a valid drive name.  
ANR8406E  
Command: Drive drive name is already defined in library library name.  
Explanation: The designated drive cannot be defined because it has already been  
defined for the specified library.  
System Action: The command is not processed.  
User Response: If you want to define an additional drive, reissue the command  
with a different drive name.  
ANR8406E (AS/400)  
Command: Drive drive name is already defined in library library name.  
Explanation: The designated drive cannot be defined because it has already been  
defined for the specified library.  
System Action: The server does not process the command.  
User Response: None.  
ANR8407E  
Command: The MODEL parameter is required for this command.  
Explanation: The MODEL parameter has not been provided; it is required.  
System Action: The command is not processed.  
User Response: Reissue the command using the MODEL parameter.  
922  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8407W (AS/400)  
Unable to VARY Command option drive Drive name.  
Explanation: The AS/400 Vary Configuration (VRYCFG) command failed for the  
specified drive. The server issues additional error messages if this condition prevents  
the server from completing an operation.  
System Action: Server operation continues.  
User Response: If necessary, use the appropriate AS/400 commands to determine  
the status of the drive and correct any problems.  
ANR8408E  
Command: The DEVICE parameter is required for this command.  
Explanation: The DEVICE parameter has not been provided; it is required.  
System Action: The command is not processed.  
User Response: Reissue the command using the DEVICE parameter.  
ANR8408W (AS/400)  
The AS/400 STATUS of drive drive name is AS/400 status.  
Explanation: The server has determined the current AS/400 status of the given  
drive. The AS/400 status of the drive may have prevented the server from using the  
drive. The server issues additional error messages if this condition prevents the  
server from completing an operation.  
System Action: Server operation continues.  
User Response: If necessary, use the appropriate actions to resolve any problems  
with the specified drive. If the drive is shared with other systems, ensure that the  
SHARE parameter associated with the drive is set correctly in the DEFINE DRIVE  
command.  
ANR8409E  
Command: Library library name is not defined.  
Explanation: The designated library has not been defined.  
System Action: The command is not processed.  
User Response: Reissue the command using a different library name, or define the  
library before retrying the command.  
ANR8409E (AS/400)  
Command: Library library name is not defined.  
Explanation: The designated library has not been defined.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command and specify a different library name, or  
define the library before reissuing the command.  
ANR8410I  
Library library name deleted.  
Explanation: The designated library has been deleted successfully.  
System Action: The library is deleted.  
User Response: None.  
ANR8410I (AS/400)  
Library library name deleted.  
Explanation: The designated library has been deleted successfully.  
System Action: The library is deleted.  
User Response: None.  
ANR8411E  
Command: One or more drives are still defined in library library name.  
Explanation: The designated library cannot be deleted because there are still  
drives defined within it.  
System Action: The command is not processed.  
User Response: Delete all drives from the library, and reissue the command.  
ANR8411E (AS/400)  
Command: One or more drives are still defined in library library name.  
Explanation: The designated library cannot be deleted because there are still  
drives defined within it.  
System Action: The server does not process the command.  
User Response: Delete all drives from the library, and reissue the command.  
ANR8412I  
Drive drive name deleted from library library name.  
Explanation: The designated drive has been deleted successfully from the  
specified library.  
System Action: The drive is deleted.  
User Response: None.  
924  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8412I (AS/400)  
Drive drive name deleted from library library name.  
Explanation: The designated drive has been deleted successfully from the  
specified library.  
System Action: The drive is deleted.  
User Response: None.  
ANR8413E  
Command: Drive drive name is currently in use.  
Explanation: The designated drive cannot be deleted or updated because it is  
currently in use.  
System Action: The command is not processed.  
User Response: Wait until the drive is no longer in use, and reissue the command.  
ANR8413E (AS/400)  
Command: Drive drive name is currently in use.  
Explanation: The designated drive cannot be deleted or updated because it is  
currently in use.  
System Action: The server does not process the command.  
User Response: Wait until the drive is no longer in use, and then reissue the  
command.  
ANR8414E  
Command: Drive drive name is not defined in library library name.  
Explanation: The designated drive has not been defined in the given library.  
System Action: The command is not processed.  
User Response: Reissue the command using a different drive name. If appropriate,  
define the drive before retrying the command.  
ANR8414E (AS/400)  
Command: Drive drive name is not defined in library library name.  
Explanation: The designated drive has not been defined in the given library.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify a different drive name; or, if  
appropriate, define the drive before reissuing the command.  
Tivoli Storage Manager Messages  
925  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8415E  
Command: The parameter parameter is required for this command.  
Explanation: The specified parameter must be provided when processing the given  
command.  
System Action: The command is not processed.  
User Response: Reissue the command, providing the required parameter value.  
ANR8415E (AS/400)  
Command: The parameter parameter is required for this command.  
Explanation: The specified parameter must be provided when processing the given  
command.  
System Action: The server does not process the command.  
User Response: Reissue the command and provide the required parameter value.  
ANR8416E  
Command: The parameter parameter is invalid for library type library type.  
Explanation: The specified parameter is not valid for libraries of the given type.  
The scratchcategory must be at least 2 less than the privatecategory for 349x  
libraries.  
System Action: The command is not processed.  
User Response: Reissue the command, using only the proper parameters. If using  
the scratchcategory make sure it is at least 2 less than the privatecategory.  
ANR8416E (AS/400)  
Command: The parameter parameter is invalid for library type library type.  
Explanation: The specified parameter is not allowed for libraries of the given  
type.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify only valid parameters.  
ANR8417E  
Command: The parameter parameter is invalid for drives in library type  
libraries.  
Explanation: The specified parameter is not allowed when defining or updating  
drives in a library of the given type.  
System Action: The command is not processed.  
User Response: Reissue the command, using only the proper parameters.  
926  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8417E (AS/400)  
Command: The parameter parameter is invalid for drives in library type  
libraries.  
Explanation: The specified parameter is not allowed when defining or updating  
drives in a library of the given type.  
System Action: The server does not process the command.  
User Response: Reissue the command and specify only valid parameters.  
ANR8418E  
Command: An I/O error occurred while accessing library library name.  
Explanation: An I/O error occurs while accessing the designated library.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the library is  
identified correctly in the DEFINE LIBRARY command, and that the library is  
currently powered on and ready. If the library has an access door, make sure it is  
closed. After checking and correcting these potential problems, retry the operation.  
ANR8418E (AS/400)  
Command: An I/O error occurred while accessing library library name.  
Explanation: An I/O error occurs while accessing the designated library.  
System Action: The operation fails.  
User Response: Ensure that the MLD parameter associated with the library is  
identified correctly in the DEFINE LIBRARY command, and that the library is  
currently powered on and ready. If the library has an access door, make sure it is  
closed. After checking and correcting these potential problems, you can try the  
operation again.  
ANR8419E  
Command: The drive or element conflicts with an existing drive in library  
library name.  
Explanation: Either there are no more physical drives in the library, or the  
specified ELEMENT parameter conflicts with an existing defined drive in the given  
library.  
System Action: The command is not processed.  
User Response: Specify a valid ELEMENT parameter that is not used by any  
other drive in the library.  
Tivoli Storage Manager Messages  
927  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8420E  
Command: An I/O error occurred while accessing drive drive name.  
Explanation: An I/O error occurs while accessing the specified drive.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive is  
identified correctly in the DEFINE DRIVE command, and that the drive is currently  
powered on and ready. After checking and correcting these potential problems, retry  
the command.  
ANR8420E (AS/400)  
Command: An I/O error occurred while accessing drive drive name.  
Explanation: An I/O error occurs while accessing the specified drive.  
System Action: The operation fails.  
User Response: Ensure that the DEVICE parameter associated with the drive is  
identified correctly in the DEFINE DRIVE command, and that the drive is currently  
powered on and ready. After checking and correcting these potential problems, you  
can try the operation again.  
ANR8421E  
Command: Unable to start a process for this command.  
Explanation: The server cannot start a background process to carry out the  
designated command.  
System Action: The operation fails.  
User Response: Check for and correct memory shortages or other server resource  
constraints, and reissue the command.  
ANR8421E (AS/400)  
Command: Unable to start a process for this command.  
Explanation: The server cannot start a background process to carry out the  
designated command.  
System Action: The operation fails.  
User Response: Check for and correct memory shortages or other server resource  
constraints, and then reissue the command.  
ANR8422I  
Command: Operation for library library name started as process process ID.  
Explanation: A volume check-in process has been started to handle the insertion  
of a volume into the given library. The process is assigned the ID specified in the  
message.  
928  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server starts a background process to perform the operation in  
response to the CHECKIN LIBVOLUME command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
ANR8422I (AS/400)  
Command: Operation for library library name started as process process ID.  
Explanation: A volume check-in process has been started to handle the insertion  
of a volume into the given library. The process is assigned the ID specified in the  
message.  
System Action: The server starts a background process to perform the operation in  
response to the CHECKIN LIBVOLUME command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. To cancel the process, issue the CANCEL PROCESS command.  
ANR8423I  
CHECKIN LIBVOLUME process for library library name has been canceled.  
Explanation: A background server process that has been working to check in one  
or more volumes for the given library is canceled by the CANCEL PROCESS  
command.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
ANR8423I (AS/400)  
CHECKIN LIBVOLUME process for library library name has been canceled.  
Explanation: The CANCEL PROCESS command cancels a background server  
process that has been working to check in one or more volumes for the given  
library.  
System Action: The server process is ended and server operation continues.  
User Response: No action is required.  
ANR8424I  
Checking in volume volume name in library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKIN LIBVOLUME process on the server. The given  
volume is being checked in to the designated library.  
System Action: The background process operation continues.  
User Response: None. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
Tivoli Storage Manager Messages  
929  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8424I (AS/400)  
Checking in volume volume name in library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKIN LIBVOLUME process on the server. The given  
volume is being checked into the designated library.  
System Action: The background process operation continues.  
User Response: No action is required. An authorized administrator can cancel the  
process by using the CANCEL PROCESS command.  
ANR8425I  
Checking in volumes in search mode in library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKIN LIBVOLUME process on the server. Volumes  
are being checked into the given library automatically using a search for  
previously-unknown volumes.  
System Action: The background process operation continues.  
User Response: None. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
ANR8425I (AS/400)  
Checking in volumes using search mode in library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKIN LIBVOLUME process on the server. Volumes  
are being checked into the given library automatically using a search for previously  
unknown volumes.  
System Action: The background process operation continues.  
User Response: No action is required. An authorized administrator can cancel the  
process by using the CANCEL PROCESS command.  
ANR8426E  
CHECKIN LIBVOLUME for volume volume name in library library name  
failed.  
Explanation: The background process for a CHECKIN LIBVOLUME command  
has failed.  
System Action: The background process ends, but the volume has not been  
checked into the library.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, and then reissue the command.  
930  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8426E (AS/400)  
CHECKIN LIBVOLUME for volume volume name in library library name  
failed.  
Explanation: The background process for a CHECKIN LIBVOLUME command  
has failed.  
System Action: The background process terminates, but the volume has not been  
checked into the library.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, and then reissue the command.  
ANR8427I  
CHECKIN LIBVOLUME for volume volume name in library library name  
completed successfully.  
Explanation: The specified volume was successfully checked in to the library  
during processing of a CHECKIN LIBVOLUME or LABEL LIBVOLUME  
command.  
System Action: The volume is made available for mounting in the given library.  
User Response: None.  
ANR8427I (AS/400)  
CHECKIN LIBVOLUME for volume volume name in library library name  
completed successfully.  
Explanation: The background process for a CHECKIN LIBVOLUME command  
has completed successfully.  
System Action: The volume is made available for mounting in the given library.  
User Response: No action is required.  
ANR8428E  
Command: The STATUS parameter is required for this command.  
Explanation: The STATUS parameter must be provided with the given command.  
System Action: The command is not processed.  
User Response: Reissue the command, and provide a valid STATUS parameter  
value.  
ANR8428E (AS/400)  
Command: The STATUS parameter is required for this command.  
Explanation: The STATUS parameter must be provided with the given command.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
931  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reissue the command and provide a valid STATUS parameter  
value.  
ANR8429E  
Command: No drives are currently defined in library library name.  
Explanation: The command cannot be issued until at least one drive has been  
defined in the given library.  
System Action: The command is not processed.  
User Response: Define a drive in the library, using the DEFINE DRIVE  
command, and then retry the failed command.  
ANR8429E (AS/400)  
Command: No drives are currently defined in library library name.  
Explanation: The server cannot process the command until at least one drive has  
been defined in the given library.  
System Action: The server does not process the command.  
User Response: By using the DEFINE DRIVE command, define a drive in the  
library, and then reissue the failed command.  
ANR8430I  
Volume volume name has been checked into library library name.  
Explanation: A search-mode CHECKIN LIBVOLUME process has found the  
given volume and automatically checked it into the library.  
System Action: The volume is added to the given library’s inventory.  
User Response: None.  
ANR8430I (AS/400)  
Volume volume name has been checked into library library name.  
Explanation: A search-mode CHECKIN LIBVOLUME process has found the  
given volume and automatically checked it into the library.  
System Action: The volume is added to the given library’s inventory.  
User Response: No action is required.  
ANR8431I  
CHECKIN LIBVOLUME process completed for library library name; volume  
count volume(s) found.  
Explanation: A search-mode CHECKIN LIBVOLUME process is completed. The  
specified number of volumes have been successfully added to the library’s  
inventory.  
932  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The volumes are made available for use by the server.  
User Response: None.  
ANR8431I (AS/400)  
CHECKIN LIBVOLUME process completed for library library name; volume  
count volumes found.  
Explanation: A search-mode CHECKIN LIBVOLUME process is completed. The  
specified number of volumes have been successfully added to the library’s  
inventory.  
System Action: The volumes are made available for use by the server.  
User Response: No action is required.  
ANR8432E  
Command: Volume volume name is already present in library library name.  
Explanation: The specified volume cannot be checked into the given library  
because it is already present.  
System Action: The command is not processed.  
User Response: Provide the name of a volume that is not already present in the  
given library. Use the QUERY LIBVOLUME command to obtain a full list of  
volumes that have already been checked into the library.  
ANR8432E (AS/400)  
Command: Volume volume name is already present in library library name.  
Explanation: The specified volume cannot be checked into the given library  
because it is already present.  
System Action: The server does not process the command.  
User Response: Provide the name of a volume that is not already present in the  
given library. Use the QUERY LIBVOLUME command to obtain a full list of  
volumes that have already been checked into the library.  
ANR8433E  
Command: Volume volume name is not present in library library name.  
Explanation: The specified volume cannot be checked out of the given library  
because it is not present.  
System Action: The command is not processed.  
User Response: Provide the name of a volume that is present in the given library.  
Use the QUERY LIBVOLUME command to obtain a full list of volumes that reside  
in the library.  
Tivoli Storage Manager Messages  
933  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8433E (AS/400)  
Command: Volume volume name is not present in library library name.  
Explanation: The specified volume cannot be checked out of the given library  
because it is not present.  
System Action: The server does not process the command.  
User Response: Provide the name of a volume that is present in the given library.  
Use the QUERY LIBVOLUME command to obtain a full list of volumes that reside  
in the library.  
ANR8434I  
Command: Operation for volume volume name in library library name started as  
process process ID.  
Explanation: A volume check-out process has been started to handle the removal  
of a volume from the given library. The process is assigned the ID specified in the  
message.  
System Action: The server starts a background process to perform the operation in  
response to the CHECKOUT LIBVOLUME command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
ANR8434I (AS/400)  
Command: Operation for volume volume name in library library name started as  
process process ID.  
Explanation: A volume check-out process has been started to handle the removal  
of a volume from the given library. The process is assigned the ID specified in the  
message.  
System Action: The server starts a background process to perform the operation in  
response to the CHECKOUT LIBVOLUME command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
ANR8435I  
CHECKOUT LIBVOLUME for volume volume name in library library name  
has been canceled.  
Explanation: A background server process that has been working to check out the  
volume from the given library is canceled by the CANCEL PROCESS command.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
934  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8435I (AS/400)  
CHECKOUT LIBVOLUME for volume volume name in library library name  
has been canceled.  
Explanation: The CANCEL PROCESS command cancels a background server  
process that has been working to check out the volume from the given library.  
System Action: The server process is ended and server operation continues.  
User Response: No action is required.  
ANR8436I  
Checking out volume volume name from library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKOUT LIBVOLUME process on the server.  
System Action: The background process operation continues.  
User Response: None. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
ANR8436I (AS/400)  
Checking out volume volume name from library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKOUT LIBVOLUME process on the server.  
System Action: The background process operation continues.  
User Response: No action is required. An authorized administrator can cancel the  
process by using the CANCEL PROCESS command.  
ANR8437E  
CHECKOUT LIBVOLUME for volume volume name in library library name  
failed.  
Explanation: The background process for a CHECKOUT LIBVOLUME command  
has failed.  
System Action: The background process ends, but the volume has not been  
checked out of the library.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, then retry the command.  
Tivoli Storage Manager Messages  
935  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8437E (AS/400)  
CHECKOUT LIBVOLUME for volume volume name in library library name  
failed.  
Explanation: The background process for a CHECKOUT LIBVOLUME command  
has failed.  
System Action: The background process ends, but the volume has not been  
checked out of the library.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, and then reissue the command.  
ANR8438I  
CHECKOUT LIBVOLUME for volume volume name in library library name  
completed successfully.  
Explanation: The background process for a CHECKOUT LIBVOLUME command  
has completed successfully.  
System Action: The volume is either deleted from the library’s inventory (if its  
status is something other than DATA) or marked not present (if its status is DATA).  
User Response: None.  
ANR8438I (AS/400)  
CHECKOUT LIBVOLUME for volume volume name in library library name  
completed successfully.  
Explanation: The background process for a CHECKOUT LIBVOLUME command  
has completed successfully.  
System Action: The volume is either deleted from the library’s inventory (if its  
status is something other than DATA) or marked “not present” (if its status is  
DATA).  
User Response: No action is required.  
ANR8439I  
SCSI library library name is ready for operations.  
Explanation: The initialization process for the given library has completed  
successfully, and the library is ready for use.  
System Action: The library is made ready for use.  
User Response: None.  
936  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8439E (AS/400)  
Command: The parameter parameter is invalid for the type of drive.  
Explanation: The specified parameter is not allowed when defining or updating  
the given type of drive.  
System Action: The server does not process the command.  
User Response: Reissue the command using only valid parameters.  
ANR8440E  
Initialization failed for SCSI library library name; will retry in delay time  
minute(s).  
Explanation: The initialization process for the given library has failed. It will be  
retried automatically after the specified amount of time has elapsed.  
System Action: The initialization will be retried later.  
User Response: Ensure that the library device is powered on and ready. If the  
library has an access door, make sure it is in the closed position.  
ANR8441E  
Initialization failed for SCSI library library name.  
Explanation: The initialization process for the given library has failed, and will  
not be retried until the next time the server needs to access the library.  
System Action: The library is made temporarily unavailable.  
User Response: Make sure the library is powered on and attached.  
ANR8442E  
Command: Volume volume name in library library name is currently in use.  
Explanation: The command cannot be processed because the specified volume is  
already being used for another operation.  
System Action: The command is not processed.  
User Response: Wait until the conflicting volume activity has completed, and then  
reissue the command. If the volume is currently mounted, but idle, you can  
dismount it with the DISMOUNT VOLUME command and then retry this  
operation.  
ANR8442E (AS/400)  
Command: Volume volume name in library library name is currently in use.  
Explanation: The command cannot be processed because the specified volume is  
already being used for another operation.  
System Action: The server does not process the command.  
Tivoli Storage Manager Messages  
937  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Wait until the conflicting volume activity has completed, and then  
reissue the command. If the volume is currently mounted but idle, you can dismount  
it by using the DISMOUNT VOLUME command and then try this operation again.  
ANR8443E  
Command: Volume volume name in library library name cannot be assigned a  
status of SCRATCH.  
Explanation: The volume cannot be assigned to the given library’s scratch pool  
because there is a storage pool volume defined or a volume in the volume history  
file with this volume name. Such a volume may still contain valid data. Assigning  
the volume to the library’s scratch pool might result in a destructive overwrite of the  
volume’s data.  
System Action: The command is not processed.  
User Response: Reissue the command, specifying that the volume be assigned a  
status of PRIVATE.  
ANR8443E (AS/400)  
Command: Volume volume name in library library name cannot be assigned a  
status of SCRATCH.  
Explanation: The volume cannot be assigned to the given library’s scratch pool  
because there is a storage pool volume defined with this volume name. Assigning  
the volume to the library’s scratch pool may result in a destructive overwrite of the  
volume’s data.  
System Action: The server does not process the command.  
User Response: Reissue the command, and specify that the volume be assigned a  
status of PRIVATE.  
ANR8444E  
Command: Library library name is currently unavailable.  
Explanation: The requested operation cannot be completed because the specified  
library is unavailable for I/O operations. The library may still be carrying out its  
initialization operations.  
System Action: The command is not processed.  
User Response: Wait until the library initialization completes or the library  
becomes ready.  
938  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8444E (AS/400)  
Command: Library library name is currently unavailable.  
Explanation: The requested operation cannot be completed because the specified  
library is unavailable for I/O operations. The library may be carrying out its  
initialization operations.  
System Action: The server does not process the command.  
User Response: Retry the requested operation when the library initialization  
completes or when the library becomes ready.  
ANR8445I  
Volume volume name in library library name updated.  
Explanation: The specified library volume has been updated successfully.  
System Action: The library volume inventory is updated.  
User Response: None.  
ANR8445I (AS/400)  
Volume volume name in library library name updated.  
Explanation: The specified library volume has been updated successfully.  
System Action: The library volume inventory is updated.  
User Response: None.  
ANR8446I  
Manual intervention required for library library name.  
Explanation: The specified library requires manual intervention.  
System Action: Current library activity will be delayed until the required  
intervention occurs.  
User Response: If the library has an access door, make sure it is in the closed  
position. If it has a cartridge carousel, make sure the carousel is installed. The  
server automatically detects when the appropriate action has been taken; it will then  
continue its operations.  
ANR8446I (AS/400)  
Manual intervention required for library library name.  
Explanation: The specified library requires manual intervention.  
System Action: Current library activity is delayed until the required intervention  
occurs.  
Tivoli Storage Manager Messages  
939  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the library has an access door, make sure it is in the closed  
position. If it has a cartridge carousel, make sure the carousel is installed. The  
server automatically detects when the appropriate action has been taken. It then  
continues its operations.  
ANR8447E  
No drives are currently available in library library name.  
Explanation: The attempted operation cannot be completed on the specified  
library because there are no available drives. A drive may be unavailable because an  
application other than the server may have the driver opened. This message may  
also be issued if a CHECKIN or LABEL command is issued and no drive is  
available to service the operation. This can be because all the drives are mounted by  
other processes or sessions, or the device type was incorrectly specified.  
System Action: The attempted operation is terminated.  
User Response: Use the QUERY DRIVE command to check the online status of  
the drives. Drives that are marked Unavailable since hh:mm yy/mm/ddare drives  
taken offline by the server at the time specified because of hardware failures or the  
inability to open the drive. If the attempted operation is a CHECKIN or LABEL  
command, use the QUERY MOUNT command to determine if all the drives in the  
library are mounted and wait until one of these is available. If there are mounted  
volumes with an IDLE status, use the DISMOUNT VOLUME command to free its  
drive, and retry the original operation.  
ANR8447E (AS/400)  
No drives are currently available in library library name.  
Explanation: No drives are available to carry out an attempted operation for the  
specified library. The drives can be unavailable for the following reasons. One or  
more drives in the library may already be in use by the server. One or more drives  
in the library may be in use by other jobs or other systems. The AS/400 status of  
one or more drives may render them unavailable to the server. Additional messages  
may have been issued by the server.  
System Action: The attempted operation is ended.  
User Response: If the attempted operation is IMPORT/EXPORT or  
DUMP/LOAD, wait until a drive is available in the library, and then try the  
operation again. If there are idle volumes mounted in the library, use the  
DISMOUNT VOLUME command to free a drive, and then try the original  
operation again. If any of the drives in the library are shared, wait until the other  
system makes a drive available, and then try the original operation again. If the  
attempted operation is a normal data storage operation, make sure that the number  
of drives defined in the library is greater than or equal to the MOUNTLIMIT value  
of the device class that references the library. This can be accomplished by either  
defining more drives in the library or by reducing the MOUNTLIMIT value of the  
940  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
device class. If the drives are in use by other jobs or systems, attempt to coordinate  
server operations and the availability of the drives.  
ANR8448E  
Scratch volume volume name from library library name rejected - volume name  
is already in use.  
Explanation: The designated volume has been used to satisfy a scratch mount, but  
the volume is already defined in a storage pool, or has been used to store server  
export, database dump, or database backup information as recorded in the server  
volume history file.  
System Action: The volume is rejected.  
User Response: Use a volume that is not in use, or check out and relabel the  
rejected volume, assigning it a new name in the process, or delete the existing  
volume that caused the name conflict.  
ANR8448I (AS/400)  
Scratch volume volume name from library library name rejected - volume name  
is already in use.  
Explanation: The designated volume has been used to satisfy a scratch mount, but  
the volume is already defined in a storage pool, or has been used to store server  
export, database dump, or database backup information as recorded in the server  
volume history file.  
System Action: The volume is rejected.  
User Response: Use a volume that is not in use, or check out and relabel the  
rejected volume, assigning it a new name in the process, or delete the existing  
volume that caused the name conflict.  
ANR8449E  
Scratch volume volume name rejected - volume name is already in use.  
Explanation: The designated volume has been used to satisfy a scratch mount, but  
the volume is already defined in a storage pool, or has been used to store server  
export, database dump, or database backup information as recorded in the server  
volume history file.  
System Action: The volume is rejected.  
User Response: Use a volume that is not in use, or rename the rejected volume or  
delete the existing volume that caused the name conflict.  
Tivoli Storage Manager Messages  
941  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8449I (AS/400)  
Scratch volume volume name rejected - volume name is already in use.  
Explanation: The designated volume has been used to satisfy a scratch mount, but  
the volume is already defined in a storage pool, or has been used to store server  
export, database dump, or database backup information as recorded in the server  
volume history file.  
System Action: The volume is rejected.  
User Response: Use a volume that is not in use, or rename the rejected volume, or  
delete the existing volume that is causing the name conflict.  
ANR8450E  
Command: Library library name is currently in use.  
Explanation: The designated library cannot be deleted or updated because it is  
currently in use for an I/O operation.  
System Action: The command is not processed.  
User Response: Wait until the library is no longer in use, and then retry the  
command.  
ANR8450E (AS/400)  
Command: Library library name is currently in use.  
Explanation: The designated library cannot be deleted or updated because it is  
currently in use for an I/O operation.  
System Action: The server does not process the command.  
User Response: Wait until the library is no longer in use, and reissue the  
command.  
ANR8451I  
349X library library name is ready for operations.  
Explanation: The initialization process for the given library has completed  
successfully, and the library is ready for use.  
System Action: The library is made ready for use.  
User Response: None.  
ANR8451I (AS/400)  
Media Library Device library name is ready for operations.  
Explanation: The initialization process for the given library has completed  
successfully, and the library is ready for use.  
System Action: The library is made ready for use.  
942  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: No action is required.  
ANR8452E  
Initialization failed for 349X library library name; will retry in delay time  
minute(s).  
Explanation: The initialization process for the given library has failed. It is retried  
automatically after the specified amount of time has elapsed.  
System Action: The initialization will be retried later.  
User Response: Ensure that the library device is powered on and ready.  
ANR8452E (AS/400)  
Initialization failed for Media Library Device library name; will retry in delay  
time minutes.  
Explanation: The initialization process for the given library has failed. It is tried  
again automatically after the specified amount of time has elapsed.  
System Action: The initialization is tried again later.  
User Response: Ensure that the library device is powered on and ready.  
ANR8453E  
Initialization failed for 349X library library name.  
Explanation: The initialization process for the given library has failed and will not  
be retried until the next time the server needs to access the library.  
System Action: The library is made temporarily unavailable.  
User Response: None.  
ANR8453E (AS/400)  
Initialization failed for Media Library Device library name.  
Explanation: The initialization process for the given library has failed and will not  
be retried until the next time the server needs to access the library. Check previously  
issued messages for additional information.  
System Action: The library is made temporarily unavailable.  
User Response: None.  
ANR8454E  
Mismatch detected between external label (volume name from external label) and  
media label (volume name from media label) in 349X library library name.  
Explanation: The external label of a volume was found to differ from its media  
label in the designated library.  
Tivoli Storage Manager Messages  
943  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The volume will not be accessed.  
User Response: Remove the volume from the library and ensure that it is properly  
labeled.  
ANR8454I (AS/400)  
Mismatch detected between external label (volume name from external label) and  
media label in Media Library Device library name.  
Explanation: The external label of a volume is different from its media label in  
the designated library.  
System Action: The volume is not accessed.  
User Response: Remove the volume from the library and ensure that it is properly  
labeled.  
ANR8455E  
Volume volume name could not be located during audit of library library name.  
Volume has been removed from the library inventory.  
Explanation: While processing an AUDIT LIBRARY command for the given  
library, the server cannot find the given volume in the library.  
System Action: The volume is removed from the library inventory.  
User Response: If the volume is needed, it should be located and checked into the  
library using the CHECKIN LIBVOLUME command.  
ANR8455I (AS/400)  
Volume volume name could not be located during audit of library library name.  
Explanation: While processing an AUDIT LIBRARY command for the given  
library, the server cannot find the given volume in the library.  
System Action: The volume is removed from the library inventory.  
User Response: If the volume is needed, locate it and check it into the library by  
using the CHECKIN LIBVOLUME command.  
ANR8456E  
Multiple volumes named volume name were found during audit of library  
library name.  
Explanation: While processing an AUDIT LIBRARY command for the given  
library, multiple physical volumes are found to have the same name.  
System Action: The first instance of the volume is retained in the server  
inventory; all other instances are ignored.  
User Response: Remove all of the redundant instances of the volume from the  
library. If the volume which the server retained is found to be the incorrect one, it  
944  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
can be checked out with the CHECKOUT LIBVOLUME command; then the correct  
instance can be checked into the library with a CHECKIN LIBVOLUME command.  
ANR8456I (AS/400)  
Multiple volumes named volume name were found during audit of library  
library name.  
Explanation: While processing an AUDIT LIBRARY command for the given  
library, multiple physical volumes are found to have the same name.  
System Action: The first occurrence of the volume is retained in the server  
inventory. All other occurrences are ignored.  
User Response: Remove all the duplicate occurrences of the volume from the  
library. If the volume that the server retained is the incorrect one, check it out with  
the CHECKOUT LIBVOLUME command. Check the correct instance into the  
library with a CHECKIN LIBVOLUME command.  
ANR8457I  
Command: Operation for library library name started as process process ID.  
Explanation: A library audit process has been started for the given library. The  
process is assigned the ID specified in the message.  
System Action: The server starts a background process to perform the operation in  
response to the AUDIT LIBRARY command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
ANR8457I (AS/400)  
Command: Operation for library library name started as process process ID.  
Explanation: A library audit process has been started for the given library. The  
process is assigned the ID specified in the message.  
System Action: The server starts a background process to perform the operation in  
response to the AUDIT LIBRARY command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
ANR8458I  
AUDIT LIBRARY process for library library name has been canceled.  
Explanation: A background server process that has been working to audit the  
given library is canceled by the CANCEL PROCESS command.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
Tivoli Storage Manager Messages  
945  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8458I (AS/400)  
AUDIT LIBRARY process for library library name has been canceled.  
Explanation: A background server process that has been working to audit the  
given library is canceled by the CANCEL PROCESS command.  
System Action: The server process is ended and server operation continues.  
User Response: No action is required.  
ANR8459I  
Auditing volume inventory for library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for an AUDIT LIBRARY process on the server.  
System Action: Server operation continues.  
User Response: None. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
ANR8459I (AS/400)  
Auditing volume inventory for library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for an AUDIT LIBRARY process on the server.  
User Response: No action is required. The process may be canceled by an  
authorized administrator by using the CANCEL PROCESS command.  
ANR8460E  
AUDIT LIBRARY process for library library name failed.  
Explanation: The background process for an AUDIT LIBRARY command has  
failed.  
System Action: The background process ends.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, then reissue the command.  
ANR8460E (AS/400)  
AUDIT LIBRARY process for library library name failed.  
Explanation: The background process for an AUDIT LIBRARY command has  
failed.  
System Action: The background process ends.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, and then reissue the command.  
946  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8461I  
AUDIT LIBRARY process for library library name completed successfully.  
Explanation: The background process for an AUDIT LIBRARY command has  
completed successfully.  
System Action: The library inventory is updated to match the contents of the  
library as found during the audit operation.  
User Response: None.  
ANR8461I (AS/400)  
AUDIT LIBRARY process for library library name completed successfully.  
Explanation: The background process for an AUDIT LIBRARY command has  
completed successfully.  
System Action: The library inventory is updated to match the contents of the  
library as found during the audit operation.  
User Response: No action is required.  
ANR8462I  
End-of-side reached for device type volume volume name.  
Explanation: The server has detected an end-of-side condition for the given two  
sided volume.  
System Action: The server will access the second side of the volume.  
User Response: None.  
ANR8463E  
Device type volume volume name is write protected.  
Explanation: The server has detected a write-protect condition for the given  
volume.  
System Action: The server will dismount the volume and continue processing with  
another volume.  
User Response: Adjust the write-protect switch on the volume so that writing is  
allowed. If the volume is an optical volume and the write-protect switch is already  
set to allow writing, use the MOVE DATA command to move the data off of the  
volume. Rewritable volumes may be reformatted and reused after the data is moved  
to another volume.  
ANR8463E (AS/400)  
Device type volume volume name is write protected.  
Explanation: The server has detected a write protect condition for the given  
volume.  
Tivoli Storage Manager Messages  
947  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server dismounts the volume and continues processing with  
another volume.  
User Response: Adjust the write protect switch on the volume so that writing is  
allowed.  
ANR8464E  
command: Invalid update request for library library name.  
Explanation: An invalid update request has been made for the given library. This  
can occur if a new device name is given and the characteristics of the device do not  
match the characteristics of the original device.  
System Action: The server does not process the command.  
User Response: If a different type of library device has been installed, the old  
library definition must be deleted with a DELETE LIBRARY command, and a new  
library must be defined. The UPDATE LIBRARY command cannot be used in this  
case.  
ANR8464E (AS/400)  
Invalid update request for library library name.  
Explanation: An invalid update request has been made for the given library. This  
can occur if a new device name is given and the characteristics of the device do not  
match the characteristics of the original device.  
System Action: The server does not process the command.  
User Response: If a different type of library device has been installed, delete the  
old library definition with a DELETE LIBRARY command, and define a new  
library. The UPDATE LIBRARY command cannot be used in this case.  
ANR8465I  
Library library name updated.  
Explanation: An UPDATE LIBRARY request has been successfully processed for  
the given library.  
System Action: The server updates its information about the library.  
User Response: None.  
ANR8465I (AS/400)  
Library library name updated.  
Explanation: An UPDATE LIBRARY request has been successfully processed for  
the given library.  
System Action: The server updates its information about the library.  
User Response: None.  
948  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8466E  
command: Invalid update request for drive drive name in library library name.  
Explanation: An invalid update request has been made for the given drive. This  
can occur if a new device name is given and the characteristics of the device do not  
match the characteristics of the original device.  
System Action: The server does not process the command.  
User Response: If a different type of drive has been installed, the old drive  
definition must be deleted with a DELETE DRIVE operation, and a new drive must  
be defined. The UPDATE DRIVE command cannot be used in this case.  
ANR8466E (AS/400)  
Invalid update request for drive drive name in library library name.  
Explanation: An invalid update request has been made for the given drive. This  
can occur if a new device name is given and the characteristics of the device do not  
match the characteristics of the original device.  
System Action: The server does not process the command.  
User Response: If a different type of drive has been installed, delete the old drive  
definition with a DELETE DRIVE command, and define a new drive. The UPDATE  
DRIVE command cannot be used in this case.  
ANR8467I  
Drive drive name in library library name updated.  
Explanation: An UPDATE DRIVE request has been successfully processed for the  
given drive.  
System Action: The server updates its information about the drive.  
User Response: None.  
ANR8467I (AS/400)  
Drive drive name in library library name updated.  
Explanation: An UPDATE DRIVE request has been successfully processed for the  
given drive.  
System Action: The server updates its information about the drive.  
User Response: None.  
ANR8468I  
device type volume volume name dismounted from drive drive name in library  
library name.  
Explanation: The specified volume has been dismounted from the given drive.  
System Action: None.  
Tivoli Storage Manager Messages  
949  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the type of the given library is MANUAL, the operator may  
elect to remove the volume (which has already been ejected) from the drive and  
store it in an appropriate location. For automated libraries, this message is purely  
informational.  
ANR8468I (AS/400)  
Device type volume volume name dismounted from drive drive name in library  
library name.  
Explanation: The specified volume has been dismounted from the given drive.  
System Action: None.  
User Response: If the type of the given library is MANUAL or USRDFN, the  
operator may elect to remove the volume (which has already been ejected) from the  
drive and store it in an appropriate location. For automated libraries, this message is  
only informational.  
ANR8469E  
Dismount of device type volume volume name from drive drive name in library  
library name failed.  
Explanation: An attempt to dismount the designated volume failed due to an I/O  
error.  
System Action: None.  
User Response: If the type of the given library is MANUAL, the volume can be  
manually ejected and removed from the drive. For automated libraries, manual  
intervention may be required to correct the problem.  
ANR8469E (AS/400)  
Dismount of device type volume volume name from drive drive name in library  
library name failed.  
Explanation: An attempt to dismount the designated volume failed due to an I/O  
error or a DISMOUNT Exit error.  
System Action: None.  
User Response: If the type of the given library is MANUAL or USRDFN, the  
volume can be manually ejected and removed from the drive. For automated  
libraries, manual intervention may be required to correct the problem.  
ANR8470W  
Initialization failure on drive drive name in library library name.  
Explanation: The specified drive could not be initialized at this time.  
System Action: The initialization of the specified library continues.  
950  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine previous messages for additional information regarding  
the specified drive.  
ANR8471E  
Drive drive name of library library name is offline; server no longer polling  
drive.  
Explanation: The server is unable to use the mentioned drive. This may be for the  
following reasons:  
The drive cannot be opened  
In the case of a 3494 or a library that can be partitioned, the drive may be  
unavailable to the library manager, may be in use by another application, or  
may be loaded with a cartridge not labeled for server use.  
System Action: The drive is offline and is not used for tape operations.  
User Response: Determine the reason the drive is inaccessible, such as hardware  
errors reported in the system logs. Render any needed corrections to the drive. Then,  
the drive may be made online by issuing the UPDATE DRIVE command with the  
ONLINE=YES option.  
ANR8472I  
Error reading label of volume in drive drive name of library library name.  
Explanation: While processing a search-mode CHECKIN LIBVOLUME  
command for the designated library, the server finds a volume whose label cannot  
be read.  
System Action: The volume is dismounted and is not checked into the library.  
User Response: Remove the volume from the library and ensure that it is properly  
labeled. After doing so, the volume can be checked into the library.  
ANR8493I  
device type volume volume name mounted in drive drive name in library library  
name.  
Explanation: The specified volume has been mounted in the specified drive.  
System Action: None.  
User Response: For automated libraries, this message is purely informational.  
ANR8494E  
Command: An option specified is not valid for library type libraries.  
Explanation: A requested option is not valid for libraries of the given type for the  
specified command.  
System Action: The command is not processed.  
User Response: None.  
Tivoli Storage Manager Messages  
951  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8495E  
Device type volume volume name cannot be written by BACKUP DB operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new BACKUP DB data to be written to it. Or there is no space  
available on the destination filespace to write this backup to.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested BACKUP DB command, or that  
there is not enough space available.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the BACKUP DB command.  
ANR8496E  
ANR8497E  
ANR8498E  
Device class device class not defined in device configuration information file.  
Explanation: The command that has been issued requires that the specified device  
class be defined in the device configuration information file. This definition was not  
found or the statements in the file are in the wrong order.  
System Action: The command is not processed.  
User Response: Reissue the command, and specify a valid device class. Refresh  
your device configuration information file by issuing the BACKUP DEVCONFIG  
command.  
Library library not defined in device configuration information file.  
Explanation: The specified command requires that the specified library be defined  
in the device configuration information file. This definition was not found or the  
statements in the file are in the wrong order.  
System Action: The command is not processed.  
User Response: Refresh your device configuration information file by issuing the  
BACKUP DEVCONFIG command. Make sure a library is defined for the device  
class. Reissue the command.  
Drive not defined for library library in device configuration information file.  
Explanation: The specified command requires that the specified drive be defined  
in the device configuration information file for the specified library. This definition  
was not found or the statements in the file are in the wrong order.  
System Action: The command is not processed.  
User Response: Refresh your device configuration information file by issuing the  
BACKUP DEVCONFIG command. Make sure a drive is defined for the library  
associated with the device class. Reissue the command.  
952  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8499I  
Command accepted.  
Explanation: The command is accepted and processed by the server.  
System Action: The server processes the command.  
User Response: None.  
ANR8499I (AS/400)  
Command accepted.  
Explanation: The command is accepted and processed by the server.  
System Action: The server processes the command.  
User Response: None.  
ANR8511E (AS/400)  
Message queue library name/message queue name is not available.  
Explanation: Either the message queue object does not exist or the authority is  
incorrect.  
System Action: The command is not processed.  
User Response: Correct the message queue object name, create the message queue  
object, or change the authority and reissue the command.  
ANR8512I (AS/400)  
Message queue is set to library name/message queue name.  
Explanation: The message queue is set successfully.  
System Action: The message queue is set successfully. Messages will be sent to  
the message queue.  
User Response: None.  
ANR8513I (AS/400)  
Message queue is set to the value of the message queue.  
Explanation: The message queue is set to a special value. For example, *NONE″  
is to turn off the message queue; *SYOPRis to send the messages to the system  
operator’s message queue.  
System Action: The message queue is set successfully. Messages will be sent to  
the message queue.  
User Response: None.  
Tivoli Storage Manager Messages  
953  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8550E (AIX) Error opening filespec.  
Explanation: An error occurs while attempting an open operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the open  
operation failed; correct the problem and restart the process.  
ANR8550E (AS/400)  
Error opening filespec.  
Explanation: ADSM detects an error while attempting an open operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the open  
operation has failed. Correct the problem and restart the process.  
ANR8550E (HP-UX)  
Error opening file name.  
Explanation: An error occurs while the server attempts a file open operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the open  
operation failed; correct the problem and restart the process.  
ANR8550E (Solaris)  
Error opening file name.  
Explanation: An error occurs while the server attempts a file open operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the open  
operation failed; correct the problem and restart the process.  
ANR8550E (Windows NT)  
Error opening filespec.  
Explanation: The server detects an error while attempting an open operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the open  
operation has failed; correct the problem and restart the process.  
954  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8551E (AIX) An error (error code) occurred during a write operation.  
Explanation: An error occurs while attempting a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation failed; correct the problem and restart the process.  
ANR8551E (AS/400)  
An error (error code) occurred during a write operation.  
Explanation: ADSM detects an error while attempting a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation has failed; correct the problem and restart the process.  
ANR8551E (HP-UX)  
An error (error code) occurred during a write operation.  
Explanation: An error occurs while the server attempts a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation failed; correct the problem and restart the process.  
ANR8551E (Solaris)  
An error (error code) occurred during a write operation.  
Explanation: An error occurs while the server attempts a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation failed; Correct the problem and restart the process.  
ANR8551E (Windows NT)  
An error (error code) occurred during a write operation.  
Explanation: The server detects an error while attempting a write operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the write  
operation has failed; correct the problem and restart the process.  
Tivoli Storage Manager Messages  
955  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8552E (AIX) An error (error code) occurred during a read operation.  
Explanation: An error occurs while attempting a read operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the read  
operation failed; correct the problem and restart the process.  
ANR8552E (AS/400)  
An error (error code) occurred during a read operation.  
Explanation: ADSM detects an error while attempting a read operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the read  
operation has failed. Correct the problem and restart the process.  
ANR8552E (HP-UX)  
An error (error code) occurred during a read operation.  
Explanation: An error occurs while the server attempts a read operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the read  
operation failed; correct the problem and restart the process.  
ANR8552E (Solaris)  
An error (error code) occurred during a read operation.  
Explanation: An error occurs while the server attempts a read operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the read  
operation failed; correct the problem and restart the process.  
ANR8552E (Windows NT)  
An error (error code) occurred during a read operation.  
Explanation: The server detects an error while attempting a read operation.  
System Action: Server processing continues.  
User Response: Refer to the other displayed messages to determine why the read  
operation has failed; correct the problem and restart the process.  
956  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8553E (AIX) Device type volume volume name cannot be overwritten by DUMPDB operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new DUMPDB data to be written to it.  
System Action: The server has detected that the given volume already contains  
some data that would be overwritten by the requested DUMPDB operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the DUMPDB operation.  
ANR8553E (AS/400)  
Device type volume volume name cannot be overwritten by DUMPDB operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new DUMPDB data to be written to it.  
System Action: The server detects that the given volume already contains data that  
would be overwritten by the requested DUMPDB operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it, and try the DUMPDB operation again.  
ANR8553E (HP-UX)  
Device type volume volume name cannot be overwritten by DUMPDB operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new DUMPDB data to be written to it.  
System Action: The server has detected that the given volume already contains  
data that would be overwritten by the requested DUMPDB operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the DUMPDB operation, or specify a different volume name.  
ANR8553E (Solaris)  
Device type volume volume name cannot be overwritten by DUMPDB operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new DUMPDB data to be written to it.  
System Action: The server has detected that the given volume already contains  
data that would be overwritten by the requested DUMPDB operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the DUMPDB operation, or specify a different volume name.  
Tivoli Storage Manager Messages  
957  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8553E (Windows NT)  
Device type volume volume name cannot be overwritten by DUMPDB operation.  
Explanation: The specified volume already exists or contains data, so that the  
server cannot allow new DUMPDB data to be written to it.  
System Action: The server detects that the given volume already contains some  
data that would be overwritten by the requested DUMPDB operation.  
User Response: If the specified volume does not contain any valuable data, delete  
it and retry the DUMPDB operation.  
ANR8554W (AIX)  
Dump/load command: Device class device class name not defined. Devtype of  
FILE is assumed.  
Explanation: The specified device class name is not defined with the  
DUMPLOADDB DEVCLASS option, to the server in the server options file or the  
server is not able to define the specified device class.  
System Action: Processing continues. The dump/load process assumes the device  
class is devtype=FILE and writes to or reads from a file.  
User Response: Refer to the other displayed messages to determine why the  
device class is not defined. Correct the problem and restart the command if you do  
not wish to write to or read from a file.  
ANR8554W (AS/400)  
Dump/load command: Device class device class name not defined. Devtype of  
FILE is assumed.  
Explanation: The specified device class name is not defined with the  
DUMPLOADDB DEVCLASS option to the server in the server options file or the  
server cannot define the specified device class.  
System Action: Processing continues. The dump/load process assumes the device  
class is devtype=FILE, and writes to or reads from a file.  
User Response: Refer to the other displayed messages to determine why the  
device class has not been defined. Correct the problem and restart the command if  
you do not wish to write to or read from a file.  
958  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8554W (HP-UX)  
Dump/load command: Device class device class name not defined. Devtype of  
FILE is assumed.  
Explanation: The specified device class name is not defined with the  
DUMPLOADDB DEVCLASS option, to the server in the server options file or the  
server is not able to define the specified device class.  
System Action: Processing continues. The dump/load process assumes the device  
class is devtype=FILE and writes to or reads from a file.  
User Response: Refer to the other displayed messages to determine why the  
device class is not defined. Correct the problem and restart the command if you do  
not wish to write to or read from a file.  
ANR8554W (Solaris)  
Dump/load command: Device class device class name not defined. Devtype of  
FILE is assumed.  
Explanation: The specified device class name is not defined with the  
DUMPLOADDB DEVCLASS option, to the server in the server options file or the  
server is not able to define the specified device class.  
System Action: Processing continues. The dump/load process assumes the device  
class is devtype=FILE and writes to or reads from a file.  
User Response: Refer to the other displayed messages to determine why the  
device class is not defined. Correct the problem and restart the command if you do  
not wish to write to or read from a file.  
ANR8555W (AS/400)  
Command: The value of this command results in ADSM recovery files that  
cannot be edited on the AS/400.  
Explanation: The SET LRECLRECOVERYFILE command has changed the value  
of this option to greater than 240. An AS/400 file with an LRECL greater than 240  
cannot be edited on the AS/400. The ADSM recovery files affected by this option  
are the volume history file, the device configuration file and the DRM recovery plan  
file.  
System Action: The server processes the command.  
User Response: Ignore the warning or set the LRECLRECOVERYFILE option to  
a value less than 241. If the warning is ignored and it becomes necessary to edit the  
ADSM recovery files, the files will have to be edited on a platform other than the  
AS/400 and returned to the AS/400. For example, it may be necessary to FTP the  
files to a PC Workstation, edit them there and FTP the changed files back to the  
AS/400. While editing the files, ensure that the new LRECL does not exceed that of  
Tivoli Storage Manager Messages  
959  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the original files on the AS/400. If the LRECL of the files is increased during the  
edit process, they will be truncated when they are returned to the AS/400.  
Note: If an ADSM recovery file exists with an LRECL that is different than what is  
being used on the LRECLRECOVERYFILE option, the existing file must be  
deleted and re-created with the appropriate BACKUP command. For  
example, the device configuration file is re-created with the BACKUP  
DEVCONFIG command.  
ANR8556W (AS/400)  
LRECLRECOVERYFILE statement in file filespec results in ADSM recovery  
files that cannot be edited on the AS/400.  
Explanation: While processing the specified server options file, the server has  
encountered an LRECLRECOVERYFILE statement with a value greater than 240.  
An AS/400 file with an LRECL greater than 240 cannot be edited on the AS/400.  
The ADSM recovery files affected by this option are the volume history file, the  
device configuration file and the DRM recovery plan file.  
System Action: Server initialization continues.  
User Response: Ignore the warning or change the LRECLRECOVERYFILE  
statement to a value less than 241 and restart the server. If the warning is ignored  
and it becomes necessary to edit the ADSM recovery files, the files will have to be  
edited on a platform other than the AS/400 and returned to the AS/400. For  
example, it may be necessary to FTP the files to a PC Workstation, edit them there  
and FTP the changed files back to the AS/400. While editing the files, ensure that  
the new LRECL does not exceed that of the original files on the AS/400. If the  
LRECL of the files is increased during the edit process, they will be truncated when  
they are returned to the AS/400.  
Note: If an ADSM recovery file exists with an LRECL that is different than what is  
being used on the LRECLRECOVERYFILE option, the existing file must be  
deleted and re-created with the appropriate BACKUP command. For  
example, the device configuration file is re-created with the BACKUP  
DEVCONFIG command.  
ANR8557E (AS/400)  
Truncation occurred during a write operation.  
Explanation: ADSM has detected a truncation while attempting a write operation.  
System Action: The server activity which encountered this error will end, but  
server processing continues.  
User Response: Refer to the other displayed messages to determine which file was  
involved when the write operation failed. As a group, the volume history file, the  
960  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
device configuration file and the DRM recovery plan file are referred to as the  
ADSM recovery files. If the file that encountered the error is one of the ADSM  
recovery files, the problem can be corrected with one of two methods. First, the  
length of the statements being written to these files can be controlled by the values  
in certain ADSM definitions. Second, the LRECLRECOVERYFILE option can be  
changed in the server options file. The SET LRECLRECOVERYFILE command can  
be used to change it for the currently running server. If the SET  
LRECLRECOVERYFILE command is used, the server does not have to be halted.  
Once the server is halted and restarted, the value in the options file will be used. To  
make the change permanent, the options file should be updated. Prior to making a  
change to the LRECLRECOVERYFILE option, please consider that a value greater  
than 240 results in a file that cannot be edited on the AS/400. If the file that  
encountered the error is NOT one of the ADSM recovery files, correct the problem  
and restart the process.  
ANR8570E (AIX) HTTPS Initialization failed. No keyring file or keyring password were specified.  
Explanation: HTTPS required keyring file and keyring password are not found.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure server has access to keyring file and password. Re-start  
the server.  
ANR8570E (HP-UX)  
HTTPS Initialization failed. No keyring file or keyring password were specified.  
Explanation: HTTPS required keyring file and keyring password are not found.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure server has access to keyring file and password. Re-start  
the server.  
ANR8570E (Solaris)  
HTTPS Initialization failed. No keyring file or keyring password were specified.  
Explanation: HTTPS required keyring file and keyring password are not found.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure server has access to keyring file and password. Re-start  
the server.  
Tivoli Storage Manager Messages  
961  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8570E (Windows NT)  
HTTPS Initialization failed. No keyring file or keyring password were specified.  
Explanation: HTTPS required keyring file and keyring password are not found.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure server has access to keyring file and password. Re-start  
the server.  
ANR8571E (AIX) HTTPS Initialization failed. The keyring file format is invalid.  
Explanation: HTTPS required keyring file has an invalid format.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
ANR8571E (HP-UX)  
HTTPS Initialization failed. The keyring file format is invalid.  
Explanation: HTTPS required keyring file has an invalid format.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
ANR8571E (Solaris)  
HTTPS Initialization failed. The keyring file format is invalid.  
Explanation: HTTPS required keyring file has an invalid format.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
ANR8571E (Windows NT)  
HTTPS Initialization failed. The keyring file format is invalid.  
Explanation: HTTPS required keyring file has an invalid format.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
962  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8572E (AIX) HTTPS Initialization failed. The keyring file password is invalid.  
Explanation: An invalid password was specified for the HTTPS keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Obtain the correct password for the keyring file. Then re-start the  
server.  
ANR8572E (HP-UX)  
HTTPS Initialization failed. The keyring file password is invalid.  
Explanation: An invalid password was specified for the HTTPS keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Obtain the correct password for the keyring file. Then re-start the  
server.  
ANR8572E (Solaris)  
HTTPS Initialization failed. The keyring file password is invalid.  
Explanation: An invalid password was specified for the HTTPS keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Obtain the correct password for the keyring file. Then re-start the  
server.  
ANR8572E (Windows NT)  
HTTPS Initialization failed. The keyring file password is invalid.  
Explanation: An invalid password was specified for the HTTPS keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Obtain the correct password for the keyring file. Then re-start the  
server.  
ANR8573E (AIX) HTTPS Initialization failed. I/O error occurred reading the keyring file.  
Explanation: An unknown I/O error occurred reading the keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
Tivoli Storage Manager Messages  
963  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8573E (HP-UX)  
HTTPS Initialization failed. I/O error occurred reading the keyring file.  
Explanation: An unknown I/O error occurred reading the keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
ANR8573E (Solaris)  
HTTPS Initialization failed. I/O error occurred reading the keyring file.  
Explanation: An unknown I/O error occurred reading the keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
ANR8573E (Windows NT)  
HTTPS Initialization failed. I/O error occurred reading the keyring file.  
Explanation: An unknown I/O error occurred reading the keyring file.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Keyring file may be corrupted. Obtain new copy of the keyring  
file, then re-start the server.  
ANR8574E (AIX) HTTPS Initialization failed. Could not open the the keyring file.  
Explanation: The keyring file could not be found or did not allow access.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the keyring file is present and has read access allowed.  
Then re-start the server.  
ANR8574E (HP-UX)  
HTTPS Initialization failed. Could not open the the keyring file.  
Explanation: The keyring file could not be found or did not allow access.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the keyring file is present and has read access allowed.  
Then re-start the server.  
964  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8574E (Solaris)  
HTTPS Initialization failed. Could not open the the keyring file.  
Explanation: The keyring file could not be found or did not allow access.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the keyring file is present and has read access allowed.  
Then re-start the server.  
ANR8574E (Windows NT)  
HTTPS Initialization failed. Could not open the the keyring file.  
Explanation: The keyring file could not be found or did not allow access.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the keyring file is present and has read access allowed.  
Then re-start the server.  
ANR8575E (AIX) HTTPS Initialization failed. The specified certificate within the keyring file has  
expired.  
Explanation: The default or specified certificate within the keyring file has  
expired. access.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: The certificate must be renewed and re-instated into the keyring  
file. Then re-start the server.  
ANR8575E (HP-UX)  
HTTPS Initialization failed. The specified certificate within the keyring file has  
expired.  
Explanation: The default or specified certificate within the keyring file has  
expired. access.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: The certificate must be renewed and re-instated into the keyring  
file. Then re-start the server.  
ANR8575E (Solaris)  
HTTPS Initialization failed. The specified certificate within the keyring file has  
expired.  
Explanation: The default or specified certificate within the keyring file has  
expired. access.  
Tivoli Storage Manager Messages  
965  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: The certificate must be renewed and re-instated into the keyring  
file. Then re-start the server.  
ANR8575E (Windows NT)  
HTTPS Initialization failed. The specified certificate within the keyring file has  
expired.  
Explanation: The default or specified certificate within the keyring file has  
expired.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: The certificate must be renewed and re-instated into the keyring  
file. Then re-start the server.  
ANR8576E (AIX) HTTPS Initialization failed. The specified cert within the keyring file has as an  
invalid distinguished name.  
Explanation: The distinguished name for the specified cert is invalid.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the correct keyring has been specified and that the keyring  
contains the correct distinguished name. Then re-start the server.  
ANR8576E (HP-UX)  
HTTPS Initialization failed. The specified cert within the keyring file has as an  
invalid distinguished name.  
Explanation: The distinguished name for the specified cert is invalid.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the correct keyring has been specified and that the keyring  
contains the correct distinguished name. Then re-start the server.  
ANR8576E (Solaris)  
HTTPS Initialization failed. The specified cert within the keyring file has as an  
invalid distinguished name.  
Explanation: The distinguished name for the specified cert is invalid.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the correct keyring has been specified and that the keyring  
contains the correct distinguished name. Then re-start the server.  
966  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8576E (Windows NT)  
HTTPS Initialization failed. The specified cert within the keyring file has as an  
invalid distinguished name.  
Explanation: The distinguished name for the specified cert is invalid.  
System Action: The HTTPS COMMMethod is not initialized.  
User Response: Ensure the correct keyring has been specified and that the keyring  
contains the correct distinguished name. Then re-start the server.  
ANR8675E (AIX) File name with environment variable DSMSERV_DIR: File already exists for File  
or Filetext Exit.  
Explanation: The specified file already exists and the file-exit option was set to  
PRESERVE.  
System Action: Server continues running.  
User Response: Specify a non-existent file.  
ANR8675E (HP-UX)  
File name with environment variable DSMSERV_DIR: File already exists for File  
or FileText Exit.  
Explanation: The specified file already exists and the file-exit option was set to  
PRESERVE.  
System Action: Server continues running.  
User Response: Specify a non-existent file.  
ANR8675E (S/390)  
File name: File already exists for File Exit.  
Explanation: The specified file already exists and the file-exit option was set to  
PRESERVE.  
System Action: Server continues running.  
User Response: Specify a non-existent file.  
ANR8675E (Solaris)  
File name with environment variable DSMSERV_DIR: File already exists for  
File/FileText Exit, overwrite option not set to YES.  
Explanation: The specified file already exists and the overwrite option was not set  
to Yes.  
System Action: Server continues running.  
Tivoli Storage Manager Messages  
967  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Specify another file or set the overwrite option to YES in the  
server options file.  
ANR8675E (Windows NT)  
File name with path within registry.: File already exists for File or FileText Exit.  
Explanation: The specified file already exists and the File/FileText exit option was  
set to PRESERVE.  
System Action: Server continues running.  
User Response: Specify a non-existent file.  
ANR8676E (S/390)  
User specified module: Cannot load into server, system errno = Error number  
generated by MVS.  
Explanation: The server was unable to load the module specified. The module is  
not a properly C-compiled/linked dynamic module or an ASSEMBLER/PLI  
compiled module.  
System Action: Server continues running.  
User Response: Use the server supplied sample user-exit files as a starting point.  
ANR8677E (AIX) User specified module, with environment variable DSMSERV_DIR: Cannot load  
into server, system errno = Error number generated by AIX.  
Explanation: The server was unable to load the module specified. The module is  
not a properly C-compiled and linked dynamic module.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: Use the server supplied sample makefile and export files to  
compile-link the user-exit module. Make sure the export.ref file contains the  
server-defined function name, and the module actually contains the server-defined  
function name, with one void parameter declared.  
ANR8677E (HP-UX)  
User specified module, with environment variable DSMSERV_DIR: Cannot load  
into server, system errno = Error number generated by HP-UX.  
Explanation: The server was unable to load the module specified. The module is  
not a properly C-compiled and linked dynamic module.  
System Action: Server initialization stops or server continues running if already  
up.  
968  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the server supplied sample makefile and export files to  
compile-link the user-exit module. Make sure the export.ref file contains the  
server-defined function name, and the module actually contains the server-defined  
function name, with one void parameter declared.  
ANR8677E (S/390)  
The user-exit module loaded does not match with type specified in options file.  
Explanation: The server was able to load a module, but the type of the module  
did not match the type specified in the server options file  
System Action: Server initialization stops or server continues running if already  
up. The module is unloaded.  
User Response: Check the user-exit module compilation type. Make sure it  
matches with what is specified in the options file. Only C, Assembler, and PLI  
compiled modules are supported.  
ANR8677E (Solaris)  
User specified module, with environment variable DSMSERV_DIR: Cannot load  
into server, system errno = Error number generated by Solaris.  
Explanation: The server was unable to load the module specified. The module is  
not a properly C-compiled and linked dynamic module.  
System Action: Server continues running.  
User Response: Use the server supplied sample makefile, c , and h files to  
generate the user-exit module. Make sure the module contains server-defined  
function name adsmV3UserExit, and the module actually contains the server-defined  
function name, with one void * parameter declared, and returns void.  
ANR8677E (Windows NT)  
User specified module, with path within registry: Cannot load into server, system  
errno = Error number generated by NT.  
Explanation: The server was unable to load the module specified. The module is  
not a properly C-compiled and linked dynamic module.  
System Action: Server continues running.  
User Response: Use the server supplied sample makefile compile-link the user-exit  
module.  
ANR8678E (AIX) Cannot bind User specified module, with environment variable DSMSERV_DIR  
into server, system errno = Error number generated by AIX.  
Explanation: The server was unable to bind with the module specified.  
Tivoli Storage Manager Messages  
969  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: Use the server supplied sample makefile and export files to  
compile-link the user-exit module. Make sure the export.ref file contains the  
server-defined function name, and the module actually contains the server-defined  
function name, with 1 void parameter declared. The module may contain a global  
variable name that conflicts with the server’s.  
ANR8678E (HP-UX)  
Cannot bind User specified module, with environment variable DSMSERV_DIR  
into server, system errno = Error number generated by HP-UX.  
Explanation: The server was unable to bind with the module specified.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: Use the server supplied sample makefile and export files to  
compile-link the user-exit module. Make sure the export.ref file contains the  
server-defined function name, and the module actually contains the server-defined  
function name, with one void parameter declared. The module may contain a global  
variable name that conflicts with the server’s.  
ANR8678E (Solaris)  
Cannot bind User specified module, with environment variable DSMSERV_DIR  
into server, system errno = Error number generated by Solaris.  
Explanation: The server was unable to bind with the module specified. The server  
could not find a function named adsmV3UserExit in the module.  
System Action: Server continues running.  
User Response: Use the server supplied sample makefile, c and header files to  
create the user exit module. Make sure the shared library module contains a  
function named adsmV3UserExit of type void, with one parameter of a void *.  
ANR8678E (Windows NT)  
Cannot find/set User specified function name within DLL. in User specified DLL  
library name, with registry path, system errno = Error number generated by NT.  
Explanation: The server was unable to find and/or bind with the function name in  
the DLL specified.  
System Action: Server continues running.  
970  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the server supplied sample makefile to compile-link the  
user-exit module. Make sure there is a function name in the DLL as specified in the  
server options file. Make sure the function only accepts one argument, a void  
pointer.  
ANR8679W (AIX)  
There is already an user-exit loaded.  
Explanation: There was a previous successful load of an user-exit module, thus  
server cannot load another one.  
System Action: Server initilization stops or server continues running if already up.  
User Response: To load a new user-exit module, halt the server and then restart  
the server with the new user-exit module.  
ANR8679W (HP-UX)  
There is already an user-exit loaded.  
Explanation: There was a previous successful load of an user-exit module, thus  
server cannot load another one.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: To load a new user-exit module, the server must be halted and  
then restart the server with the new user-exit module.  
ANR8679W (Solaris)  
Unable to unload user exit module: system errno = Error number generated by  
Solaris.  
Explanation: The server was not able to unload the user-exit module.  
System Action: Server continues running.  
User Response: The server should be stopped at the earliest possible time before  
the user exit is to be reactivated.  
ANR8679W (Windows NT)  
There is already an user-exit loaded.  
Explanation: There was a previous successful load of an user-exit module, thus  
server cannot load another one.  
System Action: Server continues running.  
User Response: To load a new user-exit module, halt the server and then restart  
the server with the new user-exit module.  
Tivoli Storage Manager Messages  
971  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8680W (AIX)  
There is already a file used for the file or filetext exit.  
Explanation: There was a previous file open for the file or filetext exit. The server  
cannot open another one.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: To start a new file for the file or filetext exit, halt the server, then  
restart the server with the new file name.  
ANR8680W (HP-UX)  
There is already a file used for the file or filetext exit.  
Explanation: There was a previous file open for the file or filetext exit. The server  
cannot open another one.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: To start a new file for the file or filetext exit, halt the server, then  
restart the server with a new file name.  
ANR8680W (Solaris)  
There is already a named file used for the file or filetext exit.  
Explanation: There was a previous file open for the file or filetext exit. The server  
cannot open another one.  
System Action: Server initialization stops or server continues running if already  
up.  
User Response: To start a new file for the file or the filetext exit, halt the server,  
then restart the server with a new file name.  
ANR8680W (Windows NT)  
There is already a file used for the file or filetext exit.  
Explanation: There was a previous file open for the file or filetext exit. The server  
cannot open another one.  
System Action: Server continues running.  
User Response: To start a new file for the exit, halt the server, then restart the  
server with a new file name.  
972  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8681I (AIX) Connected to Tivoli event server at node name on port port.  
Explanation: The server successfully established a connection with the Tivoli  
event server on the specified node name and port.  
System Action: The server sends events to the Tivoli event server using this  
connection.  
User Response: None.  
ANR8681I (HP-UX)  
Connected to Tivoli event server at node name on port port.  
Explanation: The server successfully established a connection with the Tivoli  
event server on the specified node name and port.  
System Action: The server sends events to the Tivoli event server using this  
connection.  
User Response: None.  
ANR8681I (S/390)  
Connected to Tivoli event server at node name on port port.  
Explanation: The server successfully established a connection with the Tivoli  
event server on the specified node name and port.  
System Action: The server sends events to the Tivoli event server using this  
connection.  
User Response: None.  
ANR8681I (Solaris)  
Connected to Tivoli event server at node name on port port.  
Explanation: The server successfully established a connection with the Tivoli  
event server on the specified node name and port.  
System Action: The server sends events to the Tivoli event server using this  
connection.  
User Response: None.  
ANR8681I (Windows NT)  
Connected to Tivoli event server at node name on port port.  
Explanation: The server successfully established a connection with the Tivoli  
event server on the specified node name and port.  
Tivoli Storage Manager Messages  
973  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server sends events to the Tivoli event server using this  
connection.  
User Response: None.  
ANR8682E (AIX) Unable to determine port of Tivoli event server on node name.  
Explanation: The server was unable to determine the TCP/IP port on which the  
Tivoli event server on node name is listening.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that TECPORT is specified in the server options  
file.  
ANR8682E (HP-UX)  
Unable to determine port of Tivoli event server on node name.  
Explanation: The server was unable to determine the TCP/IP port on which the  
Tivoli event server on node name is listening.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that TECPORT is specified in the server options  
file.  
ANR8682E (S/390)  
Unable to determine port of Tivoli event server on node name.  
Explanation: The server was unable to determine the TCP/IP port on which the  
Tivoli event server on node name is listening.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that TECPORT is specified in the server options  
file.  
ANR8682E (Solaris)  
Unable to determine port of Tivoli event server on node name.  
Explanation: The server was unable to determine the TCP/IP port on which the  
Tivoli event server on node name is listening.  
974  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that TECPORT is specified in the server options  
file.  
ANR8682E (Windows NT)  
Unable to determine port of Tivoli event server on node name.  
Explanation: The server was unable to determine the TCP/IP port on which the  
Tivoli event server on node name is listening.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that TECPORT is specified in the server options  
file.  
ANR8683E (AIX) Unable to connect to the Tivoli event server at node name on port port.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server on node name at port port.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specified for TECPORT in the server  
options file is correct.  
ANR8683E (HP-UX)  
Unable to connect to the Tivoli event server at node name on port port.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server on node name at port port.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specified for TECPORT in the server  
options file is correct.  
Tivoli Storage Manager Messages  
975  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8683E (S/390)  
Unable to connect to the Tivoli event server at node name on port port.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server on node name at port port.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specified for TECPORT in the server  
options file is correct.  
ANR8683E (Solaris)  
Unable to connect to the Tivoli event server at node name on port port.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server on node name at port port.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specified for TECPORT in the server  
options file is correct.  
ANR8683E (Windows NT)  
Unable to connect to the Tivoli event server at node name on port port.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server on node name at port port.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response: Ensure that the Tivoli event server is running on the specified  
system. If the system on which the event server is running does not support the  
TCP/IP Portmapper, then ensure that the value specified for TECPORT in the server  
options file is correct.  
ANR8684E (AIX) Unable to connect to the Tivoli event server because TCP/IP is not available.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server because TCP/IP services were not available.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response:  
Ensure that COMMMETHOD TCPIP is specified in the server options file.  
976  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If COMMMETHOD TCPIP was specified, use the BEGIN EVENTLOGGING  
TIVOLI command to manually start event logging to the Tivoli event server  
once server initialization has completed.  
ANR8684E (HP-UX)  
Unable to connect to the Tivoli event server because TCP/IP is not available.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server because TCP/IP services were not available.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response:  
Ensure that COMMMETHOD=TCPIP is specified in the server options file, or  
that COMMMETHOD=NONE is not specified.  
If COMMMETHOD=TCPIP was specified, use the BEGIN EVENTLOGGING  
TIVOLI command to manually start event logging to the Tivoli event server  
once server initialization has completed.  
ANR8684E (S/390)  
Unable to connect to the Tivoli event server because TCP/IP is not available.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server because TCP/IP services were not available.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response:  
Ensure that a valid value for TCPNAME is specified in the server options file.  
If TCPNAME has the correct value, use the BEGIN EVENTLOGGING  
TIVOLI command to manually start event logging to the Tivoli event server  
once the server initialization has completed.  
ANR8684E (Solaris)  
Unable to connect to the Tivoli event server because TCP/IP is not available.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server because TCP/IP services were not available.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response:  
Ensure that COMMMETHOD=TCPIP is specified in the server options file, or  
that COMMMETHOD=NONE is not specified.  
Tivoli Storage Manager Messages  
977  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If COMMMETHOD=TCPIP was specified, use the BEGIN EVENTLOGGING  
TIVOLI command to manually start event logging to the Tivoli event server  
once server initialization has completed.  
ANR8684E (Windows NT)  
Unable to connect to the Tivoli event server because TCP/IP is not available.  
Explanation: The server was unable to establish a TCP/IP connection with the  
Tivoli event server because TCP/IP services were not available.  
System Action: Event logging to the Tivoli event server is disabled.  
User Response:  
Ensure that COMMMETHOD=TCPIP is specified in the server options file, or  
that COMMMETHOD=NONE is not specified.  
If COMMMETHOD=TCPIP was specified, use the BEGIN EVENTLOGGING  
TIVOLI command to manually start event logging to the Tivoli event server  
once server initialization has completed.  
ANR8700I (AS/400)  
Device type volume volume name has been deleted.  
Explanation: The specified volume has been deleted by the server. If the given  
device type is OPTICAL, the volume can be initialized for re-use by another  
application or the ADSM server if desired.  
System Action: The volume is removed from the server’s inventory.  
User Response: No action is required.  
ANR8701I (AS/400)  
End-of-side reached for device type volume volume name.  
Explanation: The server has detected an end-of-side condition for the given two  
sided volume.  
System Action: The server will access the second side of the volume.  
User Response: None.  
ANR8702I (AS/400)  
Initializing side side of device type volume volume name.  
Explanation: The server has started to initialize the given side of the specified  
volume in preparation for a server operation. Since the volume is two-sided, this  
message specifies which side (A or B) is being initialized by the server for I/O  
operations.  
978  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The server waits for the given side of the volume to be initialized.  
User Response: Failure to initialize the volume prevents the server from  
completing an operation. In the case of a failure, subsequent messages will provide  
the AS/400 exception encountered during the attempted initialization. Evaluate both  
the specified exception and the AS/400 action to determine the steps necessary to  
correct the problem.  
ANR8703I (AS/400)  
device type volume volume name is ready for operations.  
Explanation: The initialization process for the given volume has completed  
successfully, and the volume is ready for use.  
System Action: The volume is made ready for use.  
User Response: None.  
ANR8704E (AS/400)  
Initialization failed for device type volume volume name.  
Explanation: Initialization of the given volume has failed and has prevented the  
server from completing an operation.  
System Action: Server operation ends.  
User Response: Check previously issued messages for additional information  
regarding the error. Evaluate both the specified exception and the AS/400 action to  
determine the steps necessary to correct the problem.  
ANR8705I (AS/400)  
Device type volume volume name is mounted mount mode, status: MSGW.  
Explanation: In response to a QUERY MOUNT command, the server indicates  
that the given volume is mounted for I/O operations. The volume is currently in  
MSGW, meaning the AS/400 job that is processing the given volume for the ADSM  
server is waiting for a reply to a message on an AS/400 message queue. Locate the  
AS/400 message and provide an appropriate reply. The job should be located in the  
QSYSWRK subsystem.  
System Action: The server waits for a reply to the AS/400 message.  
User Response: Locate the AS/400 message and provide an appropriate reply.  
ANR8706E (AS/400)  
Job job number for volume volume name is in status: MSGW.  
Explanation: The specified AS/400 job is processing the given volume for the  
ADSM server. The status of the job indicates that the job is waiting for a reply to a  
Tivoli Storage Manager Messages  
979  
Download from Www.Somanuals.com. All Manuals Search And Download.  
message on an AS/400 message queue. Locate the AS/400 message and provide an  
appropriate reply. The job should be located in the QSYSWRK subsystem.  
System Action: The server waits for a reply to the AS/400 message.  
User Response: Locate the AS/400 message and provide an appropriate reply.  
ANR8707W (AS/400)  
Access state for volume volume name in library library name has been set to  
unavailable.  
Explanation: The specified volume encountered an error during mount processing  
that makes it unusable. The access state of the volume in the library volume  
inventory is changed to unavailable so that the volume is not selected for future  
mounts. One of the following may be the cause of the error. The volume may  
already be queued for use in the media library device. The volume may be mounted  
in another tape resource that is not available to the media library device. The  
volume was marked not available, or in error by the library device manager. The  
volume identifier may be a duplicate. The volume may have been manually ejected  
from the library device.  
System Action: The server sets the volume access state to unavailable. If the  
server operation requires a scratch volume, processing continues with another  
scratch volume. If the server operation required the given volume, the operation is  
terminated.  
User Response: Check previously issued ADSM messages for additional  
information regarding the error. Check the spooled files of the AS/400 user that  
started the ADSM server for messages that describe the problem with the given  
volume. The AS/400 Display Tape Cartridge (DSPTAPCTG) command can be used  
to display the attributes of a tape volume. Once the problem is corrected, update the  
access state of the volume to available by using the UPDATE LIBVOL command.  
An audit of the ADSM library will also result in a re-evaluation of the condition of  
the volume. If the volume is usable, it’s access state will be changed to available.  
An audit of the ADSM library occurs automatically during server initialization or an  
audit of the library can be started with the AUDIT LIBRARY command.  
ANR8708W (AS/400)  
The characteristics of device device name have changed: current device type  
new device type, original device type old device type.  
Explanation: The current characteristics of the designated device do not match the  
characteristics of the device when it was originally defined to the server. Either the  
device type has changed or the supported formats have changed. One of the  
following may be the cause of the change. The original device may have been  
replaced with a new device. The AS/400 configuration has changed resulting in  
different names being assigned to existing devices. The original device may have  
980  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
been upgraded to a new model. The new device characteristics will be used. This  
may result in no devices capable of supporting tape operations for the original  
characteristics. If such problems should occur, server operations will fail and the  
will server issue additional error messages.  
System Action: Server processing continues.  
User Response: You must determine if the change in device characteristics is  
acceptable given the DEVICE CLASS definitions of the server. The AS/400  
WRKHDWRSC and WRKDEVD commands can be used to display the information  
for a device. The QUERY DEVCLASS command can be used to evaluate server  
definitions. If necessary, you may need to take actions to correct the change in  
characteristis of the specified device. If possible, change the AS/400 configuration  
so that it again matches the server definition. Once the problem is corrected, the  
server must be halted and restarted so that the server may re-evaluate the device. If  
the change is correct but server operations are failing, you will need to modify the  
server definitions. If the device is associated with a server DRIVE definition, delete  
the old drive definition with a DELETE DRIVE command, and define a new drive.  
The UPDATE DRIVE command cannot be used in this case. If the device is  
associated with a server LIBRARY definition, delete the old library definition with a  
DELETE LIBRARY command, and define a new LIBRARY. The UPDATE  
LIBRARY command cannot be used in this case.  
ANR8709E (AS/400)  
Request number: Wrong type of device type volume (volume name) mounted in  
device device name for device class device class.  
Explanation: The server detects an error while attempting to open the given  
volume in the specified device. The format specified on the given device class is not  
a valid format that can be written to this volume.  
System Action: The volume is dismounted.  
User Response: Use a volume that allows the format associated with a the device  
class to be written or specify a format on the device class that can be written to this  
type of volume. Use the UPDATE DEVCLASS command to change the format for  
the device class.  
ANR8740W  
Number of automated library slots (slots in use) exceeds license terms (slots  
licensed).  
Explanation: The number of slots in use within automated libraries exceeds the  
licensed value.  
System Action: The operation completes.  
Tivoli Storage Manager Messages  
981  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your service representative to update license values for  
slots in automated libraries, or reduce the number of slots in use by issuing  
CHECKOUT LIBVOLUME commands as necessary.  
ANR8741E  
ANR8742E  
ANR8743E  
CHECKIN LIBVOLUME not permitted with current license terms.  
Explanation: The CHECKIN LIBVOLUME operation is not permitted because the  
current license terms do not allow it.  
System Action: The command fails.  
User Response: Contact your service representative to update license values for  
slots in automated libraries, or reduce the number of slots in use by issuing  
CHECKOUT LIBVOLUME commands as necessary.  
This server is not licensed to support the device type device type. Device  
Support Module module number is required.  
Explanation: A DEFINE DRIVE command or a volume mount operation cannot  
be processed because the server is not licensed to support the required device type.  
System Action: The operation fails.  
User Response: Contact your service representative to update the server license  
terms so that support for the required device type is enabled.  
This server is not licensed to support library device name. Device Support  
Module module number is required.  
Explanation: Either a DEFINE LIBRARY command, a volume mount operation,  
or library initialization cannot be processed because the server is not licensed to  
support the given library.  
System Action: The operation fails.  
User Response: Contact your service representative to update the server license  
terms so that support for the given library device is enabled.  
ANR8744E  
Command: Current license terms do not permit this operation.  
Explanation: The specified command failed because the current license terms do  
not permit it.  
System Action: The operation fails.  
User Response: Contact your service representative to update the server license  
terms so that the requested operation can be processed.  
982  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8745E  
Support for the 3590 device type is disabled for library library name.  
Explanation: The requested operation fails because support for the 3590 device  
type is not currently enabled for the specified library.  
System Action: The operation fails.  
User Response: Make sure the ENABLE3590LIBRARY option is specified in the  
server options file, and that the scratch category number for 3590 volumes does not  
conflict with the private category or the CARTRIDGE volume scratch category.  
ANR8746E  
Device type device type is not supported in this release.  
Explanation: The specified device type cannot be used by this release/platform of  
the server.  
System Action: The device cannot be used.  
User Response: Contact your sales or service representative to upgrade to the  
latest release of the server.  
ANR8747I  
Checking in volume volume name in library library name- CANCEL PENDING.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKIN LIBVOLUME process on the server. The given  
volume was being checked in to the designated library, but the process was canceled  
by an administrator.  
System Action: The background process operation is in a wait queue. When the  
process comes off the queue, it will be terminated.  
User Response: None.  
ANR8748I  
Checking in volumes in search mode in library library name- CANCEL  
PENDING.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CHECKIN LIBVOLUME process on the server. Volumes  
were being checked into the given library in search mode, but the process was  
canceled by an administrator.  
System Action: The background process operation is being terminated.  
User Response: None.  
ANR8749E  
Library order sequence check on library library name.  
Explanation: An attempt has been made to mount or demount a volume, but the  
attempt fails for one of the following reasons:  
Tivoli Storage Manager Messages  
983  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mount is already in progress or a volume is already mounted.  
Mount is already pending.  
Demount is already pending.  
Demount was requested but no volume is mounted.  
System Action: The operation fails.  
User Response: This error usually occurs when a demount fails and a cartridge is  
left in the drive. All subsequent mounts fail while attempting to insert another  
cartridge into the same drive. Demount the cartridge using the library manager or  
perform an AUDIT LIBRARY operation on the designated library. Retry the  
operation.  
ANR8750E  
Volume is incompatible with specified device type in library library name.  
Explanation: An attempt has been made to mount or check in a volume, but the  
attempt fails because the cartridge being mounted is not compatible with the drive  
(for example, attempting to mount a 3590 cartridge on a 3490 drive).  
System Action: The operation fails.  
User Response: Ensure the DEVTYPE parameter on the CHECKIN command  
matches the device type of the drive. Retry the operation.  
ANR8751W  
This server is not licensed to support the device type device type. Advanced  
Device Support is required.  
Explanation: This message is issued when a DEFINE DRIVE command or a  
volume mount operation uses a device class that is not licensed on the server.  
System Action: The operation fails if this is a try-and-buy server. For purchased  
servers, this message is to warn you that you are not in compliance with registered  
license terms.  
User Response: Contact your service representative to update the server license  
terms so that support for the required device type is enabled.  
ANR8752W  
This server is not licensed to support library device type. Advanced Device  
Support is required.  
Explanation: This message is issued when a DEFINE LIBRARY command or a  
volume mount operation uses a device class that is not licensed on the server.  
System Action: The operation fails if this is a try-and-buy server. For purchased  
servers, this message is to warn you that you are not in compliance with registered  
license terms.  
984  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your service representative to update the server license  
terms so that support for the required device type is enabled.  
ANR8760I  
Cancel in progress.  
Explanation: The MOVE MEDIA command has been canceled and will end when  
resources have been freed for the background process. This message may be  
displayed in response to a QUERY PROCESS command for a MOVE MEDIA  
command.  
System Action: Server operation continues.  
User Response: None.  
ANR8761I  
Number of volumes processed: number  
Explanation: The MOVE MEDIA command has processed the number of volumes  
displayed. This message may be displayed in response to a QUERY PROCESS  
command for a MOVE MEDIA command.  
System Action: Server operation continues.  
User Response: None.  
ANR8762I  
Number of volumes processed: number. Ejecting volume volume name from  
library library name.  
Explanation: The MOVE MEDIA command displays the number of volumes  
already processed and the name of the volume currently being ejected from the  
indicated library. This message may be displayed in response to a QUERY  
PROCESS command for a MOVE MEDIA command.  
System Action: Server operation continues.  
User Response: None.  
ANR8763E  
Command: Volume volume name not processed: library library name not defined.  
Explanation: The indicated volume is not processed since the designated library  
has not been defined or has been deleted.  
System Action: The volume is not processed.  
User Response: Reissue the command using a different library name, or define the  
library before retrying the command.  
Tivoli Storage Manager Messages  
985  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8764E  
Command: Volume volume name not processed: the operation is not allowed for  
library type library type.  
Explanation: The indicated volume is not processed since the requested operation  
is not allowed for libraries of the given type.  
System Action: The volume is not processed.  
User Response: None.  
ANR8765I  
Request number: device type volume volume name in location location name is  
required for use in library library name; CHECKIN LIBVOLUME required  
within time limit mi nutes.  
Explanation: A mount request has been made for a volume that is defined in a  
storage pool, but which is currently checked out of the given library and stored in  
the location shown.  
System Action: The server waits until it detects that the volume has been checked  
into the library, or the time limit expires.  
User Response: Obtain the required volume from the indicated location, and insert  
it into the library by issuing a CHECKIN LIBVOLUME command. Use the  
SWAP=YES option of the CHECKIN LIBVOLUME command if the library is  
currently full; this process allows the server to select an appropriate volume to be  
swapped out in order to make room for the required volume.  
ANR8766I  
MOVE MEDIA command: CHECKOUT LIBVOLUME command for volume volume  
name in library library name completed successfully; Place the ejected volume in  
location location name.  
Explanation: The CHECKOUT LIBVOLUME operation has completed  
successfully for the indicated volume in the given library. Place the ejected volume  
in the indicated location.  
System Action: The volume is either deleted from the library inventory (if its  
status is something other than DATA) or marked not present (if its status is DATA).  
User Response: If an *UNKNOWN* location is displayed, issue UPDATE  
STGPOOL OVFLOCATION command to define an overflow location name to be  
used on the subsequent MOVE MEDIA command. For the volumes ejected with an  
*UNKNOWN* location, use UPDATE VOLUME LOCATION command to update  
its location to your overflow location name.  
986  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8767I  
Number of volumes processed: number volumes processed. Volumes sent to  
library library name for checkout: number volumes sent.  
Explanation: The MOVE MEDIA command has processed the number of volumes  
shown. Currently, the MOVE MEDIA command has sent for processing the number  
of volumes shown to the library shown. This message may be displayed in response  
to a QUERY PROCESS command for a MOVE MEDIA command.  
System Action: Server operation continues.  
User Response: None.  
ANR8769E  
External media management function request type returned result=result.  
Explanation: A request of the indicated function type was sent to the external  
library manager program, which returned a result code which was not SUCCESS.  
System Action: The server continues, but the server operation that was being  
attempted fails.  
User Response: Consult the documentation for the external media management  
program to determine how to recover from the error condition. Then attempt the  
server operation again.  
ANR8770W  
Unable to load external library manager filespec.  
Explanation: A library of LIBTYPE=EXTERNAL is defined but the server cannot  
load the external library manager.  
System Action: The server continues, but the external library cannot be accessed.  
User Response: Verify that the EXTERNALMANAGER parameter for the  
external library is specified correctly on the DEFINE LIBRARY or UPDATE  
LIBRARY command.  
ANR8771E  
Volume volume name in library library name is deleted. External Library is not  
synchronized with the server. Audit required.  
Explanation: The server deleted a volume from its inventory, and its attempt to  
inform the external library manager has failed.  
System Action: The server may continue to access the library, but some volumes  
may not be accessible until the external library is synchronized with the server.  
User Response: Perform the appropriate type of processing on the external library  
in order to synchronize it with the server.  
Tivoli Storage Manager Messages  
987  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8772I  
Moving volume volume name (if known) from drive drive name to slot slot  
element number in library library name.  
Explanation: A volume found in the drive during library initialization is being  
moved to the slot.  
System Action: The volume is moved from the drive to the slot.  
User Response: None.  
ANR8773E  
Incompatible options CHECKLABEL=NO and SEARCH=YES for SCSI  
libraries.  
Explanation: If a barcode reader is not installed and detected by the server, the  
server requires the ability to check the tape label when searching for new volumes  
in a SCSI tape library. The CHECKLABEL=NO and SEARCH=YES parameters on  
the CHECKIN LIBVOL command are not compatible.  
System Action: The command fails.  
User Response: Reissue the CHECKIN LIBVOL command and specify  
CHECKLABEL=YES.  
ANR8774W  
Volume volume name not checked into library library name but is using category  
category number.  
Explanation: While processing a DEFINE LIBRARY or AUDIT LIBRARY  
command for the given library, the server found a volume that was not checked into  
the library (with the CHECKIN LIBVOL command), but is assigned to one of the  
categories in use by that library.  
System Action: If the volume category equals the value of the library  
SCRATCHCAT the category is changed to the value of the library PRIVATECAT.  
This is to prevent the library from loading the volume when a scratch volume is  
requested.  
User Response: If the volume is to be used by the server, it does not have to be  
reassigned but it must be checked into the library with the CHECKIN LIBVOL  
command. If the volume is not to be used by the server, use the mtlib program to  
reassign the volume to its correct category. For details about the mtlib program,  
refer to the documentation provided with the library device.  
ANR8775I  
Drive drive name unavailable at library manager.  
Explanation: The specified drive availability status at the library manager has  
changed from available to unavailable.  
988  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The drive status on the server is updated to reflect the availability  
to that of the library manager. The drive will not be considered as a candidate for  
the mount or demount request.  
User Response: Contact your service representative to determine the cause of the  
drive becoming unavailable. Once the service representative has determined the  
cause and changed the availability status to available at the library manager, the  
server will resume use of the drive.  
ANR8776W  
Volume volume name in drive drive name contains lost VCR data; performance  
may be degraded.  
Explanation: The Vital Cartridge Records of the cartridge in the drive are lost or  
corrupted. This results in the inability of the drive to do fast locates to file positions  
on the cartridge, which causes the locate performance for read or append operations  
to become degraded.  
System Action: The server continues the operation.  
User Response: There are two methods to restore the VCR data. The first method  
uses the MOVE DATA command to move the data off the tape and to return the  
tape to scratch or empty status. The VCR data is rebuilt when the empty tape is  
rewritten from the beginning-of-tape. The second method rebuilds the VCR by  
loading the tape and locating directly to the end-of-data. This is done by the server  
in normal use when new data is appended to the end of the tape. It can also be done  
independent of the server by loading the tape in an unused drive and using the  
tapeutil program. Select the tapeutil option Space to End-of-Data.  
ANR8777E  
Mount for volume volume name failed; media performance is degraded.  
Explanation: The VCR data on the volume is lost or corrupted, resulting in  
degraded tape positioning. The mount fails because the tape drive was configured to  
fail mounts that indicate this condition.  
System Action: The client command fails and the transaction is rolled back.  
User Response: Until the VCR data can be restored, the user can issue the  
UPDATE VOLUME command to make the volume unavailable. There are two  
methods to restore the VCR data. The first method uses the MOVE DATA  
command to move the data off the tape and to return the tape to scratch or empty  
status. The VCR data is rebuilt when the empty tape is rewritten from the  
beginning-of-tape. The second method rebuilds the VCR by loading the tape and  
locating directly to the end-of-data. This is done by the server in normal use  
whenever data is appended to the end of the tape. It can also be done independent  
of the server by loading the tape in an unused drive and using the tapeutil program.  
Select the tapeutil option Space to End-of-Data.  
Tivoli Storage Manager Messages  
989  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8778W  
Scratch volume volume name changed to Private Status to prevent re-access.  
Explanation: The scratch volume encountered an error during mount processing  
that makes it unusable. The status of the volume is changed to private so that it is  
not selected for future scratch mounts. (Although the status has become private, it is  
not defined to a storage pool.)  
System Action: Processing continues with another scratch volume.  
User Response: See previous error messages to determine the cause of the mount  
failure, and correct the problem. If the problem is a mislabeled volume or  
unreadable label, relabel the scratch volume using the dsmlabel utility with the  
-overwriteoption. If the volume is missing from its home slot, issue the AUDIT  
LIBRARY command against the library. If the volume has lost or corrupted  
VCR-data, relabel the volume. (This reinitializes the VCR-data by writing to the  
volume from beginning-of-tape.) Once the problem is corrected, update the status of  
the volume to scratch by using the UPDATE LIBVOL command.  
ANR8779E  
Unable to open drive drive name, error number=errno value from open system  
call.  
Explanation: The drive cannot be opened by the server. In AIX, error number is  
the value of errno returned by the operating system. In OS/2, it is the value of the  
return code from the call to DosOpen.  
System Action: The transaction needing the drive fails.  
User Response: Use the error number in conjunction with operating system  
documentation to narrow the scope of the cause. Inspect the drive. Ensure the drive  
is powered on and ready, the cables are properly connected and terminated, and that  
the device is properly configured to the operating system.  
ANR8780E  
Volume in drive drive name has no label.  
Explanation: The volume in the indicated drive does not have a label. The server  
requires that all media be uniquely labelled.  
System Action: The volume is rejected and the server prompts for a new volume.  
User Response: Use the appropriate labelling utility to label the media. In OS/2  
and Windows NT, the LABEL command is used to label removable disk cartridges,  
diskettes and other media which appear as drive letters.  
ANR8781E  
Volume in drive drive name has invalid label label.  
Explanation: The volume in the indicated drive has the label shown. The name  
does not conform with server requirements. The server requires that all media be  
uniquely labelled and, for removable media, that the label with file naming  
990  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
conventions. The label found exceeded the maximum label size for removable media  
or did not conform to server labelling requirements. If ????? is shown for the label,  
it indicates that server was unable to read the label.  
System Action: The volume is rejected.  
User Response: Use the appropriate labelling utility to label the media. In OS/2  
and Windows NT, the LABEL command is used to label removable disk cartridges,  
diskettes and other media which appear as drive letters. This label must still  
conform to server requirements.  
ANR8782E  
Volume volume name could not be accessed by library library name.  
Explanation: The designated volume is in the inventory of the Library Manager,  
but the physical location is either inaccessible or unknown.  
System Action: The operation fails. The access mode of the volume is changed to  
UNAVAILABLE.  
User Response: Ensure that the cartridge is physically in the library, and  
reinventory the library. If the volume location is resolved, restore the access mode  
of the volume to its previous value using the UPDATE VOLUME command.  
ANR8783E  
Label on volume in drive drive name could not be read.  
Explanation: The server was unable to read the label on the indicated drive.  
System Action: The volume is rejected.  
User Response: Use the appropriate labelling utility to label the media. In OS/2  
and Windows NT, the LABEL command is used to label removable disk cartridges,  
diskettes and other media which appear as drive letters. This label must still  
conform to server requirements.  
ANR8784E  
File file name on volume drive name could not be created.  
Explanation: The server was unable to create the indicated file on the indicated  
volume. The server creates a file on removable media in which to store data.  
System Action: The volume is rejected.  
User Response: Ensure that the media is not defective, and is properly formatted.  
Ensure that there are not large numbers of files already in the root of the file  
system. Some file systems have limits on the number of files that may be created in  
the root directory.  
Tivoli Storage Manager Messages  
991  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8785E  
Out-of-space in file system for device type volume volume name.  
Explanation: The server detected an out-of-space condition for the file system in  
which the given volume resides.  
System Action: The operation fails.  
User Response: The file system must be expanded to accommodate volume  
growth.  
ANR8786I  
Request number: Remove device type volume from entry/exit port; insert volume  
volume name mount mode into entry/exit port of library library name within time  
limit minute(s); issue ’REPLY’ along with the request ID when ready.  
Explanation: A CHECKIN LIBVOLUME command is in progress, and the  
specified volume is needed. However, there is a volume awaiting to be removed  
from the entry/exit port before the specified volume is inserted into the port of the  
given library.  
System Action: The server waits until a REPLY command is issued.  
User Response: Remove the volume from the library and insert the correct volume  
into the entry/exit port. Issue a REPLY command, along with the request ID, to tell  
the server that the volume has been removed and a new volume has been inserted.  
ANR8787W  
No barcode labels detected in library library name.  
Explanation: A command is issued with the CHECKLABEL=BARCODE option.  
The library is unable to detect that the cartridges have valid barcode labels. The  
barcode reader is disabled or it is unable to read the labels.  
System Action: Unless the command is checking in cleaning cartridges, the  
process continues by loading the cartridges into the library’s drives and reading the  
label from the tape. Cleaning cartridges have no internal label that can be checked  
by loading it in the drive.  
User Response: Cancel the process if you do not want to load all of the cartridges  
into the library’s drives. Examine the cartridges to ensure they have barcode labels  
and they are compatible with the barcode reader. Not all vendors’ labels are  
readable by all libraries. Check that the barcode reader is configured and  
functioning properly, if necessary.  
ANR8788W  
Unable to read the barcode of cartridge in slot-id Element number of slot in  
library library name; loading in drive to read label.  
Explanation: The library barcode reader is unable to read the label of a tape  
cartridge. The cartridge is found in the slot with the given element number.  
992  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The cartridge is loaded into a drive and its label will be read from  
the tape.  
User Response: Cancel the process if you do not want to load any cartridges into  
the library’s drives. Examine the cartridge to ensure it has a barcode label and that  
it is compatible with the barcode reader. Not all vendors’ labels are readable by all  
libraries. Check that the barcode reader is configured and is functioning properly, if  
necessary.  
ANR8789W  
Dynamic drive recovery being attempted on device type volume volume name  
due to errors.  
Explanation: Due to a drive or media fault, the server is moving the volume to a  
new drive.  
System Action: Read or write operations resume on the volume once it is  
remounted.  
User Response: None.  
ANR8790I  
device type volume volume name re-mounted in drive drive name.  
Explanation: Due to a drive or media fault, the server has moved the volume to  
the specified drive. Read or write operations resume on the volume.  
System Action: The label of the volume has been verified.  
User Response: None.  
ANR8791E  
Unable to move device type volume volume name to another drive.  
Explanation: Dynamic drive recovery was being attempted on the volume, but  
was unable to move the volume to another drive.  
System Action: The originating process terminates.  
User Response: See previous error messages to determine the cause of the DDR  
failure, and correct the problem. If the problem is an unreadable label, any data on  
the volume may be lost.  
ANR8792E  
Unrecoverable drive failures on drive drive name; drive is now taken offline.  
Explanation: The drive has been determined to be faulty because of recurrent  
failures.  
System Action: The drive is now marked offline.  
User Response: Service the drive for failures. Delete and redefine the drive to  
bring it back online.  
Tivoli Storage Manager Messages  
993  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8793E  
Dynamic drive recovery failed for device type volume volume name because not  
enough drives are available.  
Explanation: To recover a volume on another drive, there must be at least one  
other drive available that is not associated with the transaction which is driving the  
recovery. In addition, the maximum number of drives that can have dynamic drive  
recovery performed at the same time is one less than the number of drives. This is  
to prevent deadlock from occurring between two recovering transactions. One of  
these criteria has failed.  
System Action: No DDR is performed and the transaction fails.  
User Response: Restart the transaction.  
ANR8794E  
Retry of operation name operation failed for device type volume volume name.  
Explanation: After successfully mounting the volume on another drive, due to an  
I/O error, the original operation fails when retried.  
System Action: No further recovery is performed and the transaction fails.  
User Response: Restart the transaction.  
ANR8795I  
Retry of operation name operation for device type volume volume name is  
successful.  
Explanation: After mounting the volume on another drive, due to an I/O error, the  
operation is tried successfully.  
System Action: The transaction continues from the point of interruption from the  
failure.  
User Response: None.  
ANR8796W  
Drive drive name of library library name is not online; UPDATE DRIVE  
required.  
Explanation: During the initialization of a library, the server finds that the drive  
was updated to be offline.  
System Action: The drive will not be accessible by the library during tape  
operations.  
User Response: The drive may be made online by issuing the UPDATE DRIVE  
command with the ONLINE=YES option.  
994  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8797W  
command: Drive drive name of library library name is inaccessible.  
Explanation: The server is unable to use the mentioned drive. This may be for the  
following reasons:  
The drive cannot be opened.  
In the case of a 3494 or a library that can be partitioned, the drive may be  
unavailable to the library manager, may be in use by another application, or  
may be loaded with a cartridge not labeled for server use.  
System Action: The drive is temporarily made offline and is not used for tape  
operations. The server polls the drive at one-half minute intervals to check if the  
condition has cleared. Once the drives is accessible again, the drive is brought  
online.  
User Response: Determine the reason the drive is inaccessible, such as hardware  
errors reported in the system logs. Render any needed corrections to the drive. The  
drive will be brought online automatically when the polling process detects that is  
has become accessible.  
ANR8798W  
Drive drive name in library library name is busy; some transactions may fail.  
Explanation: The drive being made offline is currently mounted with an open tape  
volume. If the transaction using the volume requires subsequent tape mounts and is  
unable to acquire a drive, the transaction will fail.  
System Action: If this tape volume is one of a sequence of volumes that are  
required to process a transaction, a drive must be available for each mount. This  
may be any drive in the library, but if all other library drives are currently busy and  
are still busy at the time the new tape must be mounted, the transaction will fail.  
User Response: If possible, make the drive online until the transaction using it  
ends. If there is an idle volume on the drive, dismount the volume first.  
ANR8799I  
Command: Operation for library library name started as process process ID.  
Explanation: A LABEL process has been started to write the label on the  
specified volume in the given library. The process is assigned the ID specified in the  
message.  
System Action: The server starts a background process to perform the operation in  
response to the LABEL command entered by an administrator.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
Tivoli Storage Manager Messages  
995  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8800I  
LABEL LIBVOLUME for volume volume name in library library name  
completed successfully.  
Explanation: The background process to LABEL a volume has succeeded.  
System Action: The volume’s label has been rewritten.  
User Response: None.  
ANR8801I  
LABEL LIBVOLUME process process Id for library library name completed;  
count of labelled volumes volume(s) labelled, count of checked in volumes  
volume(s) checked-in.  
Explanation: A search-mode process to LABEL volumes has succeeded.  
System Action: The volumes have been labelled.  
User Response: None.  
ANR8802E  
LABEL LIBVOLUME process process Id for library library name failed.  
Explanation: The Label process terminated with a failure.  
System Action: The process ends.  
User Response: See previous error messages to determine the cause of the failure,  
and correct the problem.  
ANR8803I  
LABEL VOLUME process process Id for library library name has been  
canceled; count of labeled volumes volume(s) labeled, count of checked in volumes  
volume(s) checked-in.  
Explanation: A background server process that has been working to label the  
volumes for the given library is canceled by the CANCEL PROCESS command.  
The counts provided are for any volumes processed prior to the cancel.  
System Action: The server process is ended and server operation continues.  
User Response: None.  
ANR8804I  
Labelling volume volume name in library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a LABEL process on the server.  
System Action: The background process continues.  
User Response: None. The process may be cancelled by an authorized  
administrator using the CANCEL PROCESS command.  
996  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8805I  
Labelling volumes in library library name; volume count volumes(s) labelled.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status of a LABEL process with the SEARCH option.  
System Action: The background process continues.  
User Response: None. The process may be cancelled by an authorized  
administrator using the CANCEL PROCESS command.  
ANR8806E  
Could not write volume label volume name on the tape in library library name.  
Explanation: The Label process could not write the label on the tape specified.  
System Action: For a LABEL operation with SEARCH=YES, the background  
process continues to the next volume. For an individual volume, the process ends.  
The volume is not labelled and is not checked into the library.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, and then reissue the command.  
ANR8807W  
Could not write label volume name on the volume in drive drive name of library  
library name because volume is already labelled existing volume name.  
Explanation: The check in or label process could not write the label on the tape  
specified because the volume is already labelled.  
System Action: The check in process will not overwrite volumes that are already  
labelled, and the label process will only overwrite volumes when  
OVERWRITE=YES is specified. The volume is not labelled and cannot be checked  
in to the library. If SEARCH=YES, the process continues to the next volume. For  
an individual volume, the process ends.  
User Response: Reissue the command with the correct parameters.  
ANR8808E  
Could not write label label name on the volume in drive drive name of library  
library name because that volume is already labeled with volume name which is  
still defined in a storage pool or volume history.  
Explanation: An attempt was made to overwrite the label of a volume that is still  
defined to a storage pool or is still found in the volume history file. Such a volume  
may still contain valid data.  
System Action: The server process is ended and server operation continues.  
User Response: It is usually not necessary to re-label volumes. If the volume must  
be relabeled, that volume must first be removed from the storage pool or volume  
history file where it is defined.  
Tivoli Storage Manager Messages  
997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8809I  
Request number: Please provide the label name for the volume in slot element  
slot element number of library library name by issuing REPLY n LABEL=xxx  
within time limit minutes, where n is the re quest ID and xxx is the desired  
label name.  
Explanation: A LABEL LIBVOLUME command is in progress, and the name of  
the next volume is needed.  
System Action: The server waits until a REPLY command is issued.  
User Response: Issue a REPLY command, along with the request ID, and the  
volume name for the next cartridge.  
ANR8810I  
Volume volume name has been labeled in library library name.  
Explanation: The Label process with the search option has found and labeled a  
volume.  
System Action: The process ends.  
User Response: None.  
ANR8811E  
Command: The LABELSOURCE parameter is required when using SEARCH  
with this command.  
Explanation: The LABELSOURCE parameter must be provided with the given  
command.  
System Action: The command is not processed.  
User Response: Reissue the command, and provide a valid LABELSOURCE  
parameter value.  
ANR8812E  
Command: The SEARCH parameter is required when using LABELSOURCE  
with this command.  
Explanation: When using the LABELSOURCE option with this command, the  
SEARCH parameter must be also provided.  
System Action: The command is not processed.  
User Response: Reissue the command, and provide a valid SEARCH parameter  
value.  
ANR8813W  
Unable to read the barcode of cartridge in slot element Element number of slot  
in library library name.  
Explanation: The library barcode reader is unable to read the label of a tape  
cartridge. The cartridge is found in the slot with the given element number.  
998  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: When LABELSOURCE=BARCODE is specified on the LABEL  
LIBVOLUME command, volumes without a barcode cannot be labelled.  
User Response: Examine the cartridge to ensure it has a barcode label and that it  
is compatible with the barcode reader. Not all vendors’ labels are readable by all  
libraries. Check that the barcode reader is configured and is functioning properly, if  
necessary.  
ANR8814I  
ANR8815I  
ANR8816E  
Remove volume Volume name from slot element Slot element number of library  
Library name.  
Explanation: LABEL LIBVOLUME has ended for the specified volume and that  
volume must be removed from the library because either it was not checked in or  
there was an error.  
System Action: The server continues normal operation.  
User Response: Remove the specified volume from the library.  
Remove volume Volume name from port element Port element number of library  
Library name.  
Explanation: LABEL LIBVOLUME has ended for the specified volume and that  
volume must be removed from the library because either it was not checked in or  
there was an error.  
System Action: The server continues normal operation.  
User Response: Remove the specified volume from the library.  
command: Volume Volume name in library Library name cannot be labelled  
because it is currently defined in a storage pool or in the volume history file.  
Explanation: During command command processing, a volume cannot be used  
because there is a storage pool volume defined or a volume in the volume history  
file with this volume name. Such a volme may still contain valid data. Applying the  
volume name to the cartridge can overwrite data and or cause library inventory  
corruption. If the volume is in the volume history file, it is has previously used by  
an export, database dump, or database backup operation (as recorded in the volume  
history).  
System Action: If the SEARCH=YES option was specified, the current volume is  
skipped and command processing continues with the next volume found. If  
SEARCH=NO was specified, command processing terminates.  
User Response: If the volume is present in an automated library, it should either  
be removed or checked into the library’s inventory in the PRIVATE category.  
Tivoli Storage Manager Messages  
999  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8817E  
Name length for volume Volume nameinvalid; max is Maximum name length.  
Explanation: During LABEL LIBVOL processing, the volume name provided to  
be written on the label exceeds the maximum length for the type of cartridge.  
System Action: The label process fails for that cartridge.  
User Response: Reissue the LABEL LIBVOL command and provide a volume  
name that is not longer than the maximum listed.  
ANR8818E  
I/O Error on library library name; request for op. operation/function to the 3494  
Library Manager has timed out.  
Explanation: A command for the operation was issued to the Library Manager and  
a response was not received within the maximum timeout period.  
System Action: The operation and the transaction fails.  
User Response: Verify that communications with the library is operational, that it  
is online and ready for commands. Increase the time-out limit of the Library  
Manager Control Point device driver. If the problem persists, provide your service  
representative with the 3494 Library Manager transaction logs.  
ANR8819E  
No barcode reader detected in library library name.  
Explanation: A LABEL command was issued with the  
LABELSOURCE=BARCODE option. The library was unable to detect that the  
cartridges had valid barcode labels or the library did not have a barcode reader. If a  
barcode reader is present the reader might be disabled or it is unable to read the  
labels.  
System Action: Examine the cartridges to ensure they have barcode labels and  
they are compatible with the barcode reader. Not all vendors’ labels are readable by  
all libraries. Check that the barcode reader is configured and functioning properly.  
User Response: None.  
ANR8820W  
Repairing VCR data for Volume volume name in drive drive name; dismount  
may be delayed.  
Explanation: The Vital Cartridge Records of the cartridge in the drive are lost or  
corrupted, which results in the inability of the drive to do fast locates to file  
positions on the cartridge. The VCR is being rebuilt during the volume dismount  
process in order to avoid performance degradation on future mounts of the volume.  
System Action: The server continues the dismount operation. There may be a long  
delay because the VCR is rebuilt by spacing the tape forward to the end-of-data.  
User Response: None.  
1000  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8821E  
Barcode of element slot element address, ’hardware barcode string’, exceeds  
maximum length characters in length.  
Explanation: A barcode is encountered that was longer than a valid volume name.  
System Action: The barcode is not considered valid and will not be used for the  
server process.  
User Response: Replace the cartridge’s barcode with one that is supported by the  
library and whose number of characters does not exceed the maximum length.  
ANR8822E  
Volume name’ is not a valid volume name.  
Explanation: The specified string is not a valid volume name.  
System Action: The program prompts for a new volume name.  
User Response: Enter a volume name that is within the length constraints for the  
media type being labeled, and which contains only alphanumeric characters.  
ANR8823E  
Hardware configuration error in library library name: number of drives drives,  
number of storage slots storage slots.  
Explanation: The library device returned a count of zero for either the drives  
orthe slots. The drives may have not yet been configured to the operating system, or  
to the library. The library must have at least one drive and multiple slots when  
properly configured in order to be defined to the server.  
System Action: The operation fails.  
User Response: Configure the drives to the operating system, and reinitialize the  
library.  
ANR8824E  
I/O Error on library library name; request request id for operation  
operation/function to the 3494 Library Manager been lost.  
Explanation: A command for the operation was issued to the Library Manager and  
a response was not received within the maximum timeout period.  
System Action: The operation and the transaction fails.  
User Response: Verify that communications with the library is operational, that it  
is online and ready for commands. If the problem persists, provide your service  
representative with the 3494 Library Manager transaction logs and the request id  
from the failed operation.  
Tivoli Storage Manager Messages  
1001  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8825E  
Volume range’ is not a valid volume range.  
Explanation: The specified string is not a valid volume range.  
System Action: The program prompts for a new volume range.  
User Response: Enter the volume names in the range that is within the length  
constraints for the media type being labeled, and which contains only alphanumeric  
characters. The volume names of the begining and ending volume must be the same  
in length and the incrementals must be in digits.  
ANR8826E  
No Entry/Exit found on library library name.  
Explanation: A CHECKIN LIBVOLUME SEARCH=BULK command was issued  
on a library that has no Entry/Exit ports.  
System Action: None.  
User Response: None.  
ANR8827E  
No Entry/Exit port is available on library library name.  
Explanation: A CHECKOUT LIBVOL command was issued on a library where  
all its Entry/Exit Ports were found to be full.  
System Action: None.  
User Response: Empty all the Entry/Exit ports on the library and try the command  
again.  
ANR8828E  
Slot element number of library library name is inaccessible.  
Explanation: The slot in the library could not be physically accessed at this time.  
System Action: None.  
User Response: Verify that the Entry/Exit door is closed and the device has not  
logged any device errors before trying the command again.  
ANR8829I  
Remove volume volume name from slot element number of library library name  
at your convenience.  
Explanation: A volume has been checked out from the library and placed in a  
multiple entry/exit port library. The volume needs to be removed from the library,  
but the operation is not critical.  
System Action: None.  
User Response: Remove the volume from the entry/exit slot.  
1002  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8830E  
Internal Device type drive diagnostics detect excessive media failures for volume  
Volume name (MIM MIM Code). Access mode is now set to read-only.  
Explanation: The tape drive’s microcode performed an analysis of the media  
during the prior mount of the volume and determined that the number of temporary  
errors and other indicators exceed the threshold for reliable data recording.  
System Action: The volume is made read-only.  
User Response: Check system error logs for entries made by the device relative to  
media errors. It is recommended to move the data off the volume in order to  
minimize the impact of future errors and further damage to the media.  
ANR8831W  
Because of media errors for volume Volume name, data should be removed as  
soon as possible.  
Explanation: Errors previously encountered on the volume leave the access to the  
data in a questionable state. The errors may be permanent temporary media failures  
such as the corruption of the Volume Control Region of a Magstar drive.  
System Action: None.  
User Response: Move the data off the volume. This can be done with the MOVE  
DATA command. In some cases the tape is reusable by returning it to scratch.  
Check system error logs for entries made by the device relative to media errors. If  
the errors cannot be isolated ore resolved, contact your support representative.  
Return the tape to scratch or dispose of it.  
ANR8832E  
CHECKIN LIBVOLUME for volumes in search mode in library library name  
failed.  
Explanation: The background process for a CHECKIN LIBVOLUME command  
has failed.  
System Action: The background process ends, but volumes have not been checked  
into the library.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready, and then reissue the command.  
ANR8833E  
Command: Volume volume name in library library name is currently being  
checked in or checked out.  
Explanation: The command cannot be processed because the specified volume is  
being checked in or checked out of the library.  
System Action: The command is not processed.  
Tivoli Storage Manager Messages  
1003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Wait until the conflicting checkin or checkout has completed, and  
then reissue the command.  
ANR8834E  
Library volume volume name is still present in library library name drive drive  
name, and must be removed manually.  
Explanation: Library operations cannot be performed using the drive because a  
volume is still mounted in it. This may be due to a prior dismount failure that  
occurred on the drive.  
System Action: The command fails. The drive may be taken offline.  
User Response: See previous error messages and the system error logs to  
determine the cause of the dismount failure or any other reason the volume would  
still be loaded in the drive. Hardware diagnostics may be required. If neccessary,  
remove the volume manually and place it in its storage cell. If the storage cell is  
unknown, place the volume in any cell and issue the AUDIT LIBRARY command.  
Use the QUERY DRIVE command to determine the online status of the drive. If the  
drive is still functioning, change the status with the UPDATE DRIVE command.  
ANR8835W  
Error returning volume volume name to scratch.  
Explanation: The server external library manager sent a RELEASE request to the  
external agent for the named volume, but the external agent was unable comply  
with the request. The server, however, marked the volume scratched in its inventory;  
consequently, the server inventory and the external agent inventory are not  
consistent. This message is issued to inform the customer that the external agent  
inventory must be made consistent with the server inventory using the facilities of  
the external agent.  
System Action: The server has returned the volume to scratch status.  
User Response: Consult the documentation for the external agent and take the  
appropriate action to make the agent inventory consistent with the server inventory.  
ANR8836E  
Function RSM_function failed in server_function processing, return return code,  
call call number.  
Explanation: The library function that uses the API to the Windows NT  
Removable Storage Manager failed with a return code from the API. The call  
number represents the exact API call issued in the program.  
System Action: The function fails.  
User Response: Use the RSM documentation to determine the source of the  
problem.  
1004  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8837E  
RSM Library Library Name not supported on this Windows platform.  
Explanation: The libtype=RSM was used on a Windows platform that does not  
support RSM.  
System Action: The function fails.  
User Response: Use another library type to define the library.  
ANR8838E  
I/O error on drive drive name: excessive unit attentions received from device.  
Explanation: An operation to the drive failed with a device unit attention. These  
are normally cleared when the operation is retried, but in this case subsequent  
recover and retry attempts persistently fail with unit attention. This indicates a  
device failure.  
System Action: The operation fails.  
User Response: See accompanying error messages and the system error logs to  
determine any reason for the drive failure. Hardware diagnostics may be required. It  
may be neccessary to manually unload the volume and mark the drive offline with  
the UPDATE DRIVE command.  
ANR8839W  
Drive drive name of library library name is accessible.  
Explanation: The server is now able to use the mentioned drive that was  
inaccessible. However, the administrator has marked the drive offline while the  
drive was being polled.  
System Action: The drive is left offline and is not used for tape operations.  
User Response: Issue the UPDATE DRIVE command to bring the drive back  
online.  
ANR8840E  
Unable to open device device name with error error number.  
Explanation: The library was inaccessible thus causing a open request to fail. This  
will inturn cause the pending request to fail.  
System Action: A drive is marked inaccessible and the server starts polling the  
drive to determine if the library and drive are inaccessible. In most case, the libary  
had a temporary failure and recovers. When the server determines that the library is  
available, the drive will be brought back online.  
User Response: Verify the library is online. Verify cable connections between the  
library and the server. If the problem persists contact your service representative.  
Tivoli Storage Manager Messages  
1005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8841I  
Remove volume from slot element number of library library name at your  
convenience.  
Explanation: A volume has been placed in a multiple entry/exit port library  
because the volume should be placed back in the entry/exit port as result of the  
successful completion of a server command, or there was a problem during a server  
command. The volume needs to be removed from the library, but the operation is  
not critical.  
System Action: None.  
User Response: Remove the volume from the entry/exit slot. Examine previous  
messages for additional information regarding the specified volume and the  
command.  
ANR8842E  
ANR8846E  
ANR8847E  
The Device type drive detected a marginal sector and could not reallocate the  
sector for volume Volume name. Access mode is now set to read-only.  
Explanation: The optical drive detected a marginal sector (media error) while  
reading the volume. The drive read the sector successfully but could not reallocate  
the sector because of a previous media error.  
System Action: The volume is made read-only.  
User Response: Check system error logs for entries made by the device relative to  
media errors. It is recommended to move the data off the volume in order to  
minimize the impact of future errors and further damage to the media.  
Volume volume name is assigned to a category that does not belong to library  
library name.  
Explanation: The attempted operation on the volume cannot proceed because it is  
assigned to a category other than the insert, private, or scratch category used by the  
library.  
System Action: The attempted operation is terminated.  
User Response: Use the mtlib utility to query the volume’s category. If the  
volume is not in use by another library, use mtlib to reassign the category or choose  
another volume that is assigned to the proper category.  
No device type-type drives are currently available in library library name.  
Explanation: The attempted operation cannot be completed on the specified  
library because there are no available drives of the specified type. A drive may be  
unavailable because a different application has the drive opened. This message may  
also be issued if a CHECKIN or LABEL command is issued and no drive is  
1006  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
available to service the operation. This can be because all the drives are mounted by  
other processes or sessions, or the device type was incorrectly specified.  
System Action: The attempted operation is terminated.  
User Response: Use the QUERY DRIVE command to check the online status of  
the drives. Drives that are marked Unavailable since hh:mm yy/mm/ddare drives  
taken offline by the server at the time specified because of hardware failures or the  
inability to open the drive. If the attempted operation is a CHECKIN or LABEL  
command, use the QUERY MOUNT command to determine if all the drives in the  
library are mounted and wait until one of these is available. If there are mounted  
volumes with an IDLE status, use the DISMOUNT VOLUME command to free its  
drive, and retry the original operation. Finally, the DEVTYPE parameter is required  
for CHECKIN and LABEL commands specifying 3590 volumes in a 349X library  
that also contains 3490 drives. This is because this library also supports 3490  
volumes, and the default device type on CHECKIN and LABEL commands is  
CART (3490).  
ANR8848W  
Drive drive name of library library name is inaccessible; server has begun  
polling drive.  
Explanation: The server is unable to use the mentioned drive. This may be for the  
following reasons:  
The drive cannot be opened  
In the case of a 3494 or a library that can be partitioned, the drive may be  
unavailable to the library manager, may be in use by another application, or  
may be loaded with a cartridge not labeled for server use.  
System Action: The drive is temporarily made offline and is not used for tape  
operations. The server polls the drive at one-half minute intervals to check if the  
condition has cleared. Once the drives is accessible again, the drive is brought  
online.  
User Response: Determine the reason the drive is inaccessible, such as hardware  
errors reported in the system logs. Render any needed corrections to the drive. The  
drive will be brought online automatically when the polling process detects that is  
has become accessible.  
ANR8849E  
Command: There is already a request to delete drive drive name.  
Explanation: The designated drive cannot be deleted or updated because there is a  
request to delete the drive already.  
System Action: The command is not processed.  
User Response: None.  
Tivoli Storage Manager Messages  
1007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8850I  
ACSLS library library name is ready for operations.  
Explanation: The initialization process for the given library has completed  
successfully, and the library is ready for use.  
System Action: The library is made ready for use.  
User Response: None.  
ANR8851E  
Initialization failed for ACSLS library library name; will retry in delay time  
minute(s).  
Explanation: The initialization process for the given library has failed. It is retried  
automatically after the specified amount of time has elapsed.  
System Action: The initialization will be retried later.  
User Response: Ensure that the library device is powered on and ready.  
ANR8852E  
Initialization failed for ACSLS library library name.  
Explanation: The initialization process for the given library has failed and will not  
be retried until the next time the server needs to access the library.  
System Action: The library is made temporarily unavailable.  
User Response: None.  
ANR8853E  
Incompatible options CHECKLABEL=NO and SEARCH=YES for ACSLS  
libraries.  
Explanation: The CHECKLABEL=NO and SEARCH=YES parameters on the  
CHECKIN LIBVOL command are not compatible.  
System Action: The command fails.  
User Response: Reissue the CHECKIN LIBVOL command and specify  
CHECKLABEL=YES.  
ANR8854E  
ACSAPI(command name) invocation failed, status=acs status.  
Explanation: The ACSLS library api invocation for the given command failed.  
System Action: Depends on the server function and command, library may be  
unavailable.  
User Response: Contact your ACS System Administrator and perform ACSLS  
library problem determination.  
1008  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8855E  
ACSAPI(command name) response with unsuccessful status, status=acs status.  
Explanation: The ACSLS library api responded with an unsuccessful status as  
indicated.  
System Action: Depends on the server function and command, library may be  
unavailable.  
User Response: If the status indicates STATUS_CAP_IN_USE, it might be CAP  
priorities not set to non-zero. It might also be CAPs are not set to automatic mode,  
or CAPs are in manual mode during manual checkin. If CAP mode and priorities  
are set correctly, contact your ACS System Administrator and perform ACSLS  
library problem determination.  
ANR8856E  
ACSAPI sequence(sequence number) request(request number) timed out, elapse  
time=hours:minutes:seconds.  
Explanation: The ACSLS client has received no response from the ACSLS server  
for the period as indicated in the elapsed time. The ACSLS library api function with  
the associated sequence number is canceled if the request number is non-zero.  
System Action: Depends on the server function and command, library may be  
unavailable.  
User Response: Contact your ACS System Administrator and perform ACSLS  
library problem determination.  
ANR8857I  
ACS access control set to user_id - user id, status=acs status.  
Explanation: The ACSLS ACCESSID structure for command and volume access  
control is set the user_id as indicated.  
System Action: None.  
User Response: Ensure the indicated user_id is the same as specified in the  
environment variable ACSAPI_USER_ID.  
ANR8858W  
Unable to lock drive drive id,drive id,drive id,drive id, status=acs status.  
Explanation: The ACSLS library function acs_lock_drive failed for the specified  
drive.  
System Action: Depends on the server function and command, library drive may  
be unavailable. or may be temporary unavailable in a shared library environment.  
User Response: Contact your ACS System Administrator and perform ACSLS  
library problem determination if the problem persists.  
Tivoli Storage Manager Messages  
1009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8859W  
Unable to lock volume volume id, status=acs status.  
Explanation: The ACSLS library function acs_lock_volume failed for the  
specified volume.  
System Action: Depends on the server function and command, library volume is  
unavailable.  
User Response: Contact your ACS System Administrator and perform ACSLS  
library problem determination if the problem persist.  
ANR8860W  
Volume volume id is already locked by user id.  
Explanation: The specified volume is already locked by other user or has a  
different lock id.  
System Action: Depends on the function, the volume maybe bypassed or the  
process maybe terminated.  
User Response: This may not be an error in a shared configuration. However, if  
the existing volume lock is not needed. contact your ACSLS system administrator to  
clear the lock the volume.  
ANR8861I  
Wait and monitor the ACSSA console message to remove volume volume id  
from CAP.  
Explanation: The specified volume is about to put into CAP for removal. Monitor  
the ACSSA console and removed the volume after it has been placed into the CAP  
as indicated in the ACSSA message.  
System Action: None.  
User Response: Monitor the ACSSA console and wait.  
ANR8862I  
Unable to access ACS volume volume id.  
Explanation: The specified ACSLS volume can not be accessed in the library. The  
possible reasons might be the volume is in use, the user is not authorized, the  
volume does not exist in the library.  
System Action: Depends on the server function and command, library volume is  
unavailable.  
User Response: Contact your ACS System Administrator and perform ACSLS  
library problem determination if the problem persist..  
1010  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8863I  
ANR8864I  
ANR8865W  
ANR8866E  
Unlocking library library name volumes from the ACSLS server.  
Explanation: The volumes of the specified library are being unlocked from the  
ACSLS server.  
System Action: The operation continues. The process may take a while depends  
on the number of volumes in the library.  
User Response: None.  
ACSLS library library name is being re-initialized.  
Explanation: The specified ACSLS library is being re-initialized.  
System Action: The operation continues. The process may take a while depends  
on the number of volumes in the library. All volumes in the library are being  
locked.  
User Response: None.  
Volume volume name bypassed for command, status=acs_status.  
Explanation: The specified volume is bypassed. The volume is not in a valid  
status for the specified function.  
System Action: The operation continues.  
User Response: Determine the volume status from the ACSSA and re-issue the  
command if necessary.  
Incompatible option REMOVE=BULK for ACSLS libraries.  
Explanation: The REMOVE=BULK option is not supported for ACSLS libraries.  
The final response of ACSAPI acs_eject does not return to the application until the  
volume is removed from CAP.  
System Action: The command fails.  
User Response: Reissue the CHECKOUT LIBVOL command and specify  
REMOVE=YES or NO.  
ANR8867I  
Processing volume volume id for the command command.  
Explanation: The specified volume is being processed for the specified command.  
System Action: The command process continues.  
User Response: None.  
Tivoli Storage Manager Messages  
1011  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8868E  
Ejecting Volume volume name Failed, status = acs_status.  
Explanation: The volume is failed to be ejected from the library due to the status  
as indicated  
System Action: The operation continues.  
User Response: Determine the volume status from the message and do something  
as needed  
ANR8869E  
Command: There is already a request to update drive drive name.  
Explanation: The designated drive cannot be deleted because there is a request to  
update the drive already.  
System Action: The command is not processed.  
User Response: None.  
ANR8901E  
Command: Incompatible options STATUS=CLEANER and  
CHECKLABEL=YES.  
Explanation: Cleaner cartridges do not have internal labels that can be checked by  
loading them into the drive.  
System Action: The command fails.  
User Response: Reissue the CHECKIN LIBVOL command and include the  
parameter, CHECKLABEL=BARCODE (with SEARCH=YES specified), or include  
the parameter CHECKLABEL=NO (with the required volume name specified in the  
CHECKIN command).  
ANR8902W  
Unable to read the barcode of cleaner cartridge in slot-id Element number of slot  
in library library name; cleaner not checked in.  
Explanation: The library barcode reader is unable to read the label of a cartridge  
that is checked in as a cleaner. The cartridge is found in the slot with the given  
element number.  
System Action: The cartridge is not checked in. If the library is being searched,  
the checkin process continues with the next volume.  
User Response: Examine the cartridge to ensure it has a barcode label and that it  
is compatible with the barcode reader. Not all vendors’ labels are readable by all  
libraries. Check that the barcode reader is configured and is functioning properly.  
The cleaner cartridge can be checked in without use of the barcode label by issuing  
the CHECKIN LIBVOL command.  
1012  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8903E  
Command: Missing CLEANINGS parameter for cleaner cartridge checkin.  
Explanation: When checking in a cleaner cartridge, the CLEANINGS parameter is  
required.  
System Action: The command fails.  
User Response: Reissue the CHECKIN LIBVOL command and specify a value  
for the CLEANINGS parameter which is used to determine the number of times a  
cleaner can be mounted to clean a drive.  
ANR8904I  
Command: Cleaning operation for drive drive name in library library name  
started as process process ID.  
Explanation: A command-driven process is started to clean the specified drive.  
The process is assigned the ID that is in the message.  
System Action: In response to the CLEAN DRIVE command that is issued by an  
administrator, the server starts a background process to perform the operation.  
User Response: To obtain status on the process, issue the QUERY PROCESS  
command. The process may be canceled with the CANCEL PROCESS command.  
ANR8905I  
CLEAN DRIVE process for drive drive name in library library name is been  
canceled.  
Explanation: A background server process is has been working to clean the  
specified drive and is canceled by the CANCEL PROCESS command.  
System Action: The cleaning process is ended.  
User Response: None.  
ANR8906I  
Cleaning drive drive name in library library name.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CLEAN DRIVE process on the server. The given volume is  
being checked in to the designated library.  
System Action: The background process operation continues. The process may be  
canceled by an authorized administrator using the CANCEL PROCESS command.  
User Response: None. The process may be canceled by an authorized  
administrator using the CANCEL PROCESS command.  
ANR8907E  
CLEAN DRIVE for drive drive name in library library name failed.  
Explanation: The background process for a CLEAN DRIVE fails.  
System Action: The background process ends, but the drive is not cleaned.  
Tivoli Storage Manager Messages  
1013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Make sure the library and drive devices associated with this  
command are powered on and ready. Reissue the command.  
ANR8908I  
CLEAN DRIVE for drive drive name in library library name completed  
successfully.  
Explanation: The specified drive is successfully cleaned in the library during  
processing of a CLEAN DRIVE command.  
System Action: The drive is available for normal library operations.  
User Response: None.  
ANR8909I  
Cleaning drive drive name in library library name- CANCEL PENDING.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a CLEAN DRIVE process on the server.  
System Action: The background process operation is terminated.  
User Response: None.  
ANR8910I  
No cleaner, or no cleaner with cleanings left, found in library library name.  
Explanation: A drive is selected to be loaded with a cleaner cartridge, but no  
cleaner, or cleaner with cleanings left, is found in the library’s inventory.  
System Action: The drive is available for normal library operations.  
User Response: A cleaner should be checked in to the library by issuing the  
CHECKIN LIBVOL command.  
ANR8911W  
The cartridge in storage element slot element address in library library name is  
not a cleaner cartridge as was expected.  
Explanation: The cartridge is listed in the library’s inventory with a cleaner  
volume status. After loading the cartridge in the specified storage cell into a drive  
for cleaning, it is determined that it is not a cleaner cartridge.  
System Action: The drive is available for normal library operations.  
User Response: The cartridge should be checked out of the library by issuing the  
CHECKOUT LIBVOL command. If necessary a cleaner cartridge should be  
checked in to replace it.  
1014  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR8912E  
Unable to verify the label of volume from slot-element element-address in  
library library name.  
Explanation: The volume from the slot that is identified by the element address is  
loaded into a drive. The drive cannot be opened following the load. The label  
cannot be read to process the volume.  
System Action: The volume is stored, and processing continues with the next  
available slot.  
User Response: Check the system error logs for errors reported by the drive that  
are related to this volume. Make sure that the cartridge is not a cleaner cartridge  
that would have been loaded by mistake. If the cartridge is a cleaner, issue the  
QUERY LIBVOL command to get the correct storage slot for the cleaner and move  
the cleaner to that slot. If the cleaner is not in the library’s inventory, use the  
CHECKIN LIBVOL to check the cleaner in.  
ANR8913I  
Drive drive name in library library name is currently busy; Cleaning is  
scheduled.  
Explanation: A background process to clean the drive is unable to acquire the  
drive because the drive is busy.  
System Action: The background process operation completes. The drive is  
scheduled to be cleaned when it is unloaded.  
User Response: None.  
ANR8914I  
Drive drive name in library library name needs to be cleaned.  
Explanation: The drive has returned indicating to the server that it needs to be  
cleaned.  
System Action: The server marks the drive to be cleaned. If the drive is enabled  
for server-managed cleaning, and a cleaner cartridge is checked into the library, the  
server will load the cleaner into the drive after the current volume is dismounted.  
See the DEFINE DRIVE and QUERY DRIVE commands for information on  
enabling server-managed cleaning. See the CHECKIN LIBVOL command for  
checking a cleaner into the library.  
User Response: None.  
ANR8915I  
Cleaning cartridge cleaner name in library library name is near end of life; has  
library name uses left.  
Explanation: A cleaner cartridge is found and used, but its number of uses ih has  
left is nearly exhausted.  
System Action: The cleaning operation continues.  
Tivoli Storage Manager Messages  
1015  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: As the cleaner is used, monitor the number of cleanings that  
remain with the QUERY LIBVOL command. Remove the cleaner when all  
cleanings are exhausted. A new cleaner may be checked in so that the library is not  
left without a useful cleaner when the old cleaner is exhausted.  
ANR8919I  
ANR8920I  
ANR8921E  
Initalization and recovery has started for shared library library name.  
Explanation: The shared library has started to initialize or recover to  
resynchronize the library manager and library client.  
System Action: None.  
User Response: This process should synchronize all of the drives that are  
currently being used by this library client. This process might also start after a  
communication error or if the library client has not been able to verify drive status  
with the library manager.  
Initalization and recovery has ended for shared library library name.  
Explanation: Initialize or recover has ended the library manager and library client  
should be synchronized.  
System Action: None.  
User Response: The drives previously owned by the library client should now  
indicate they are free on the library manager. Verify this with the QUERY DRIVE  
command on the library manager. If ownership of the drives is still in question  
restart the library client and library manager.  
Unable to start library polling thread .  
Explanation: Library sharing requires that this polling thread starts. This thread  
keeps the library manager and library client synchronize with regards to drive  
ownership. These thread are started when the library is defined or when the server is  
first initalized.  
System Action: None.  
User Response: Since the polling thread did not start, the user must restart the  
server in order for library sharing to correctly work. Failure to restart the server and  
get these polling services running can cause unusual results for library clients.  
ANR8922I  
A device class for library library name was not found.  
Explanation: A library client request a mount operation to be performed by the  
library manager. The library manager is missing a device class definition for that  
library.  
System Action: None.  
1016  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Define a device class for the library using the DEFINE  
DEVCLASS command.  
ANR8923I  
Dismount failed because drive drive name in library library name is not  
currently owned by drive owner name.  
Explanation: A library client attempted to dismount on a drive that was not  
currently owned by the library client.  
System Action: None.  
User Response: None.  
ANR9579W (HP-UX)  
command: Unable to locate file file name.  
Explanation: The specified file cannot be found. Note: PREPARE assumes that  
the volume formatting program (dsmfmt) is located in the same directory as the  
server executable file.  
System Action: PREPARE uses the following default file names in the plan file:  
For the server executable the default is /opt/tivoli/tsm/server/bin/dsmserv.  
For the volume formatting program the default is  
/opt/tivoli/tsm/server/bin/dsmfmt.  
User Response: Determine why file does not exist; create if necessary.  
ANR9579W (Solaris)  
command: Unable to locate file file name.  
Explanation: The specified file cannot be found. Note: PREPARE assumes that  
the volume formatting program (dsmfmt) is located in the same directory as the  
server executable file.  
System Action: PREPARE uses the following default file names in the plan file:  
For the server executable the default is /opt/tivoli/tsm/server/bin/dsmserv.  
For the volume formatting program the default is  
/opt/tivoli/tsm/server/bin/dsmfmt.  
User Response: Determine why file does not exist; create if necessary.  
Tivoli Storage Manager Messages  
1017  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9580W (Solaris)  
Command: Generated replacement volume name volume name may not be a  
valid raw partition name. Original volume name:volume name. Stanza is stanza  
name.  
Explanation: Appending the replacement volume name postfix to the original  
volume name has created a name that may not be a valid raw partition name.  
System Action: Replacement volume name is used in the recovery plan stanza.  
User Response: Manually update the generated recovery plan stanza with a legal  
replacement name. The replacement name can be another raw partition name or a  
regular file name.  
ANR9581W (HP-UX)  
command: Volume file name not found while building stanza recovery plan stanza  
name.  
Explanation: This volume is defined to the server but does not exist. The device  
class associated with the volume is DISK or the device class device type is FILE.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: Determine why file does not exist; create if necessary.  
ANR9581W (Solaris)  
command: Volume file name not found while building stanza recovery plan stanza  
name.  
Explanation: This volume is defined to the server but does not exist. The device  
class associated with the volume is DISK or the device class device type is FILE.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: Determine why file does not exist; create if necessary.  
ANR9582E (HP-UX)  
command: Generated file name too long. Length of directory or prefix ’prefix’  
plus ’name’ exceeds maximum characters characters.  
Explanation: The file name generated is too long. The maximum valid length is  
shown in the message.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
1018  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9582E (Solaris)  
command: Generated file name too long. Length of directory or prefix ’prefix’  
plus ’name’ exceeds maximum characters characters.  
Explanation: The file name generated is too long. The maximum valid length is  
shown in the message.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9583E (HP-UX)  
command: Cannot generate fully qualified file name for ’name’.  
Explanation: A failure occurred expanding the specified file name.  
System Action: Recovery plan file not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9583E (Solaris)  
command: Cannot generate fully qualified file name for ’name’.  
Explanation: A failure occurred expanding the specified file name.  
System Action: Recovery plan file not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
Tivoli Storage Manager Messages  
1019  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARE  
ANR9584E (HP-UX)  
command: Cannot generate server options file name.  
Explanation: A failure occurred generating the server options file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9584E (Solaris)  
command: Cannot generate server options file name.  
Explanation: A failure occurred generating the server options file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9585E (HP-UX)  
command: Cannot generate a volume history file name.  
Explanation: A failure occurred generating the volume history file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9585E (Solaris)  
command: Cannot generate a volume history file name.  
Explanation: A failure occurred generating the volume history file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9586E (HP-UX)  
command: Cannot generate a device configuration file name.  
Explanation: A failure occurred generating the device configuration file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
1020  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9586E (Solaris)  
command: Cannot generate a device configuration file name.  
Explanation: A failure occurred generating the device configuration file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9600E (AIX) Invalid information passed to NETLS license interface.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9601E (AIX) The NETLS license interface was not initialized properly.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9602E (AIX) Invalid JOB information passed to the NETLS Interface.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9603E (AIX) The NETLS Nodelock file could not be created.  
Explanation: The server was not able to create the file /usr/lib/netls/conf/nodelock  
which is used for storing license password information.  
Tivoli Storage Manager Messages  
1021  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: If the server is not running with root authority, make sure that  
directory authorities in the /usr/lib/netls/conf path are set so that the user ID under  
which the server is running can create, read, and write to the  
/usr/lib/netls/conf/nodelock file. If the server is running with root authority, contact  
your service representative for assistance in resolving this problem.  
ANR9604E (AIX) The NETLS license interface encountered an internal error.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9605E (AIX) An invalid vendor ID was passed to NETLS.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9606E (AIX) NETLS failed to find socket families to contact a server.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
1022  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9607E (AIX) No NETLS Servers found.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9608E (AIX) A NETLS Security Breach was encountered.  
Explanation: The server licensing functions encountered an internal error in  
accessing license information for the server storage capacity and number of  
registered clients.  
System Action: Server operation continues. New licensing information is not used  
by the server.  
User Response: Contact your service representative for assistance in resolving the  
error.  
ANR9609E (AIX) Incorrect license entered: Password entered = password Annotation entered =  
annotation.  
Explanation: The license information entered for a REGISTER LICENSE  
command is not correct.  
System Action: None.  
User Response: Register the license again with the REGISTER LICENSE  
command. Be sure to correctly enter the license information.  
ANR9610E (AIX) Unable to create directory: directory.  
Explanation: The REGISTER LICENSE command is unable to either create or  
verify the specified directory structure.  
System Action: None.  
User Response: If the server is not running with root authority, make sure that  
directory authorities in the /usr/lib/netls/conf path are set so that the user ID under  
which the server is running can create, read, and write to the  
/usr/lib/netls/conf/nodelock file. If the server is running with root authority, contact  
your service representative for assistance in resolving this problem.  
Tivoli Storage Manager Messages  
1023  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9610E (Solaris)  
Unable to create directory: directory.  
Explanation: The REGISTER LICENSE command is unable to either create or  
verify the specified directory structure.  
System Action: None.  
User Response: If the server is not running with root authority, make sure that  
directory authorities in the given directory path are set so that the user under which  
the server is running can create, read, and write to the server’s license file. If the  
server is running with root authority, contact your service representative for  
assistance in resolving this problem.  
ANR9611E (AIX) Unable to open NODELOCK file: file.  
Explanation: The REGISTER LICENSE command is unable to either create or  
open the nodelock file.  
System Action: None.  
User Response: If the server is not running with root authority, make sure that  
directory authorities in the /usr/lib/netls/conf path are set so that the user ID under  
which the server is running can create, read, and write to the  
/usr/lib/netls/conf/nodelock file. If the server is running with root authority, contact  
your service representative for assistance in resolving this problem.  
ANR9612E (AIX) Error writing to NODELOCK file.  
Explanation: The REGISTER LICENSE command fails writing to the nodelock  
file.  
System Action: None.  
User Response: If the server is not running with root authority, make sure that  
directory authorities in the /usr/lib/netls/conf path are set so that the user ID under  
which the server is running can create, read, and write to the  
/usr/lib/netls/conf/nodelock file. If the server is running with root authority, contact  
your service representative for assistance in resolving this problem.  
ANR9613W (AIX)  
Error loading modname for Licensing function.  
Explanation: The server cannot load file module modname to initialize licensing  
functions.  
System Action: Server operation continues. Default licensing values are in effect  
for running the server.  
1024  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The dsmreg.lic module is accessed as part of the load process for  
licensing. It should be in the same directory as the dsmserv executable or it must be  
in a directory that is pointed to by the DSMSERV_DIR environment variable. The  
dsmreg.lic module is only installed when you purchase the product.  
ANR9613W (Solaris)  
Error loading modname for Licensing function.  
Explanation: The server cannot load file module modname to initialize licensing  
functions.  
System Action: Server operation continues. Default licensing values are in effect  
for running the server.  
User Response: dsmreg.lic is accessed as part of the load process for licensing. It  
should be in the same directory as the dsmserv executable file or it must be in a  
directory that is pointed to by the DSMSERV_DIR environment variable. The  
dsmreg.lic module is only installed when you purchase the product.  
ANR9614E (AIX) Unable to open license file: file.  
Explanation: The REGISTER LICENSE command is unable to create or open the  
server license file.  
System Action: None.  
User Response: Make sure that the user ID under which the server is running has  
the authority required to create or write, or both, to the license file in the directory  
in which the server is running. If this does not resolve the problem, contact your  
service representative for assistance.  
ANR9614E (Solaris)  
Unable to open license file: file.  
Explanation: The REGISTER LICENSE command is unable to either create or  
open the server license file.  
System Action: None.  
User Response: Make sure that the user ID under which the server is running has  
the authority required to create or write, or both, to the license file in the directory  
in which the server is running. If this does not resolve the problem, contact your  
service representative for assistance.  
ANR9615E (AIX) Error writing to adsmserv.licenses file.  
Explanation: The REGISTER LICENSE command fails writing to the server  
license file.  
Tivoli Storage Manager Messages  
1025  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: Make sure that the user ID under which the server is running has  
the authority required to create or write, or both, to the license file in the directory  
in which the server is running. Also, ensure that free space is available in the file  
system so that the license information can be written to the file. If this does not  
resolve the problem, contact your service representative for assistance.  
ANR9615E (Solaris)  
Error writing to adsmserv.licenses file.  
Explanation: The REGISTER LICENSE command fails writing to the server  
license file.  
System Action: None.  
User Response: Make sure that the userid under which the server is running has  
the authority required to create and/or write to the license file in the directory in  
which the server is running. Also ensure that there is free space available in the  
filesystem so that the license information can be written to the file. If this does not  
resolve the problem contact your service representative for assistance.  
ANR9616I (AIX) Invalid license record record value found in license file - it will be skipped.  
Explanation: The license manager found an invalid record in the server license  
file (adsmserv.licenses). The record is ignored.  
System Action: The invalid record is ignored.  
User Response: Erase the adsmserv.licenses file and reregister your licenses.  
ANR9616W (Solaris)  
Invalid license record record value found in license file - it will be ignored.  
Explanation: The license manager found an invalid record in the server license  
file (adsmserv.licenses). The record is ignored.  
System Action: The invalid record is ignored.  
User Response: Erase the adsmserv.licenses file and reregister your licenses. Refer  
to the licenses provided to you to ensure that only valid licenses are specified with  
the REGISTER LICENSE command.  
ANR9617I (AIX) Invalid license authorization: authorization string.  
Explanation: The license authorization specified for a REGISTER LICENSE  
command is not valid.  
1026  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: Examine the license authorization string that was entered with the  
REGISTER LICENSE command. Reenter the command if the license authorization  
was not specified correctly. If the license authorization has been specified correctly,  
contact your service representative.  
ANR9617W (Solaris)  
Invalid license authorization: authorization string.  
Explanation: The license authorization specified for a REGISTER LICENSE  
command is not valid.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: Examine the license authorization that was entered using the  
REGISTER LICENSE command. Reenter the command if the license authorization  
was not specified correctly. If the license authorization has been specified correctly,  
contact your service representative.  
ANR9618E (AIX) License registration is not supported on this server.  
Explanation: The REGISTER LICENSE command fails because the license  
authorization module cannot be found.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: The license authorization file is required for formal licensing for  
the AIX/6000 server. The file is delivered when the product is purchased, but it is  
not available in the product service stream or with demonstration copies of the  
server. If you have purchased the server, contact your service representative for  
assistance in resolving this problem.  
ANR9618E (Solaris)  
License registration is not supported on this server.  
Explanation: The REGISTER LICENSE command failed because the license  
authorization module could not be found.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: The license authorization file is required for formal licensing for  
the server. The file is delivered when the server is purchased, but is not available in  
Tivoli Storage Manager Messages  
1027  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the product service stream or with demonstration copies of the server. If you have  
purchased the server, please contact your service representation for assistance in  
resolving this problem.  
ANR9622I (AIX) An EVALUATION LICENSE for support of Tivoli Space Management will  
expire on expiration date.  
Explanation: The AIX/6000 server is distributed with an evaluation license for  
Tivoli Space Management support. If no formal license is found for the server and  
the evaluation period has not lapsed, this message is displayed each time the server  
checks the server license terms.  
System Action: The Tivoli Space Management license allows clients to utilize the  
server for storing files migrated during space management. The server checks this  
license when files are migrated to the server from client nodes to ensure that the  
server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Space  
Management after the expiration date shown.  
ANR9623I (AIX) An EVALUATION LICENSE for support of Tivoli Disaster Recovery Manager  
will expire on expiration date.  
Explanation: The AIX/6000 server is distributed with an evaluation license for  
Tivoli Disaster Recovery Manager support. If no formal license is found for the  
server and the evaluation period has not lapsed, this message is displayed each time  
the server checks the server license terms.  
System Action: The Tivoli Disaster Recovery Manager license allows customers to  
store information in the server regarding machines and recovery media, allows  
management of offsite recovery media, collects and stores information in the server  
for server recovery and allows data base and storage pool backups to a device class  
of type server. The server checks this license when machines or recovery media are  
defined to the server, when PREPARE or MOVE DRMMEDIA are invoked and  
when a data base backup or storage pool backup to a device class of type server are  
performed to ensure that the server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Disaster  
Recovery Manager after the expiration date shown.  
1028  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9624E (AIX) Unexpected error encountered in iFor/LS (SystemView License Use  
Management) routine license interface name status=xreported status code.  
Explanation: The server encountered an unexpected error in accessing the  
SystemView License Use Management function specified.  
System Action: The server license monitoring operation fails  
User Response: The SystemView License Use Management product is installed  
during normal AIX server installation. Check to make sure that server was installed  
correctly. If the installation was successful, re-boot your AIX system and re-start the  
server. If this message continues to be issued, contact your service representative.  
ANR9624I (HP-UX)  
An EVALUATION LICENSE for support of Tivoli Space Management will  
expire on expiration date.  
Explanation: The server is distributed with an evaluation license for Tivoli Space  
Management support. If no formal license is found for the server and the evaluation  
period has not lapsed, this message is displayed each time the server checks the  
server license terms.  
System Action: The Tivoli Space Management license allows clients to utilize the  
server for storing files migrated during space management. The server checks this  
license when files are migrated to the server from client nodes to ensure that the  
server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Space  
Management after the expiration date shown.  
ANR9624I (Solaris)  
An EVALUATION LICENSE for support of Tivoli Space Management will  
expire on expiration date.  
Explanation: The server is distributed with an evaluation license for Tivoli Space  
Management support. If no formal license is found for the server and the evaluation  
period has not lapsed, this message is displayed each time the server checks the  
server license terms.  
System Action: The Tivoli Space Management license allows clients to utilize the  
server for storing files migrated during space management. The server checks this  
license when files are migrated to the server from client nodes to ensure that the  
server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
Tivoli Storage Manager Messages  
1029  
Download from Www.Somanuals.com. All Manuals Search And Download.  
has elapsed. Without formal licenses, the server will not support Tivoli Space  
Management after the expiration date shown.  
ANR9624I (Windows NT)  
An EVALUATION LICENSE for support of Tivoli Space Management will  
expire on expiration date.  
Explanation: The server is distributed with an evaluation license for Tivoli Space  
Management support. If no formal license is found for the server and the evaluation  
period has not lapsed, this message is displayed each time the server checks the  
server license terms.  
System Action: The Tivoli Space Management license allows clients to utilize the  
server for storing files migrated during space management. The server checks this  
license when files are migrated to the server from client nodes to ensure that the  
server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Space  
Management after the expiration date shown.  
ANR9625E (AIX) Could not open file file name.  
Explanation: The server could not open the license certificate file specified.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9625I (HP-UX)  
An EVALUATION LICENSE for support of Tivoli Disaster Recovery Manager  
will expire on expiration date.  
Explanation: The server is distributed with an evaluation license for Tivoli  
Disaster Recovery Manager support. If no formal license is found for the server and  
the evaluation period has not lapsed, this message is displayed each time the server  
checks the server license terms.  
System Action: The Tivoli Disaster Recovery Manager license allows customers to  
store information in the server regarding machines and recovery media, allows  
management of offsite recovery media, collects and stores information in the server  
for server recovery and allows data base and storage pool backups to a device class  
of type server. The server checks this license when machines or recovery media are  
defined to the server, when PREPARE or MOVE DRMMEDIA are invoked and  
1030  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
when a data base backup or storage pool backup to a device class of type server are  
performed to ensure that the server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Disaster  
Recovery Manager after the expiration date shown.  
ANR9625I (Solaris)  
An EVALUATION LICENSE for support of Tivoli Disaster Recovery Manager  
will expire on expiration date.  
Explanation: The server is distributed with an evaluation license for Tivoli  
Disaster Recovery Manager support. If no formal license is found for the server and  
the evaluation period has not lapsed, this message is displayed each time the server  
checks the server license terms.  
System Action: The Tivoli Disaster Recovery Manager license allows customers to  
store information in the server regarding machines and recovery media, allows  
management of offsite recovery media, collects and stores information in the server  
for server recovery and allows data base and storage pool backups to a device class  
of type server. The server checks this license when machines or recovery media are  
defined to the server, when PREPARE or MOVE DRMMEDIA are invoked and  
when a data base backup or storage pool backup to a device class of type server are  
performed to ensure that the server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Disaster  
Recovery Manager after the expiration date shown.  
ANR9625I (Windows NT)  
An EVALUATION LICENSE for support of Tivoli Disaster Recovery Manager  
will expire on expiration date.  
Explanation: The server is distributed with an evaluation license for Tivoli  
Disaster Recovery Manager support. If no formal license is found for the server and  
the evaluation period has not lapsed, this message is displayed each time the server  
checks the server license terms.  
System Action: The Tivoli Disaster Recovery Manager license allows customers to  
store information in the server regarding machines and recovery media, allows  
management of offsite recovery media, collects and stores information in the server  
for server recovery and allows data base and storage pool backups to a device class  
of type server. The server checks this license when machines or recovery media are  
defined to the server, when PREPARE or MOVE DRMMEDIA are invoked and  
Tivoli Storage Manager Messages  
1031  
Download from Www.Somanuals.com. All Manuals Search And Download.  
when a data base backup or storage pool backup to a device class of type server are  
performed to ensure that the server is licensed to perform this function.  
User Response: If you are interested in using the server, contact your service  
representative to obtain formal licenses for the server before the evaluation period  
has elapsed. Without formal licenses, the server will not support Tivoli Disaster  
Recovery Manager after the expiration date shown.  
ANR9626E (AIX) Invalid license certificate file: file name.  
Explanation: The specified file does not contain valid license certificate  
information.  
System Action: The license registration command ignores the contents of the file.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9627E (AIX) Cannot access node license lock file: file name.  
Explanation: The server was not able to access the specified file. The node lock  
file contains licensing information for the server.  
System Action: The license function fails.  
User Response: Examine the file specification displayed and ensure that the file  
attributes will allow the server to access the file. The location of the file is either in  
the directory from which the server is started, or in the directory specified by the  
DSMSERV_DIR environment variable. Re-specify the DSMSERV_DIR environment  
variable if this specification is in error. Also ensure that there is sufficient space on  
the drive specified for the file. If the problem persists after these corrections have  
been made, contact your service representative.  
ANR9628E (Windows NT)  
Unexpected error encountered in iFor/LS (SystemView License Use  
Management) routine license interface name status=xreported status code.  
Explanation: The server encountered an unexpected error in accessing the  
SystemView License Use Management function specified.  
System Action: The server license monitoring operation fails  
User Response: The SystemView License Use Management product is installed  
during normal server installation. Check to make sure that the product was installed  
correctly. If the installation was successful, re-boot your system and re-start the  
server. If this message continues to be issued, contact your service representative.  
1032  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9629E (Windows NT)  
Could not open file file name.  
Explanation: The server could not open the license certificate file specified.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9630E (Windows NT)  
Invalid license certificate file: file name.  
Explanation: The specified file does not contain valid license certificate  
information.  
System Action: The license registration command ignores the contents of the file.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9631E (Windows NT)  
Cannot access node license lock file: file name.  
Explanation: The server was not able to access the specified file. The node lock  
file contains licensing information for the server.  
System Action: The license function fails.  
User Response: Examine the file specification displayed and ensure that the file  
attributes will allow the server to access the file. The location of the file is either in  
the directory from which the server is started, or in the directory specified by the  
DSMSERV_DIR environment variable. Re-specify the DSMSER-DIR environment  
variable if this specification is in error. Also ensure that there is sufficient space on  
the drive specified for the file. If the problem persists after these corrections have  
been made, contact your service representative.  
ANR9632I (Windows NT)  
Cannot load licensing DLL library: DLL file name : the server will assume  
evaluation licensing mode.  
Explanation: The server was not able to load the specified dynamic link library.  
System Action: Server licensing asumes Try and Buy mode with licenses for 180  
days.  
Tivoli Storage Manager Messages  
1033  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The named DLL library(ies) are required for the server to support  
feature licensing. If you are running an evaluation copy of the server, this message  
should not cause concern and is normal. If the libraries are installed and this  
message continues to be issued, contact a support representative for assistance.  
ANR9634E (AIX) command name: No license certificate files were found with the file name  
specification specification.  
Explanation: The server did not find any license certificate file(s) with the file  
name specification entered.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
The file name specification indicates the fully qualified file name the server was  
trying to read. The directory used to locate the license certificate files when no  
explicit path is provided is determined as follows:  
The directory path pointed by the environmental variable DSMSERV_DIR if  
this variable is defined  
The current working directory of the server process if the DSMSERV_DIR  
variable is not defined  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9634E (HP-UX)  
command name: No license certificate files were found with the file name  
specification specification.  
Explanation: The server did not find any license certificate file(s) with the file  
name specification entered.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9634E (Solaris)  
command name: No license certificate files were found with the file name  
specification specification.  
Explanation: The server did not find any license certificate file(s) with the file  
name specification entered.  
1034  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9634E (Windows NT)  
command name: No license certificate files were found with the file name  
specification specification.  
Explanation: The server did not find any license certificate file(s) with the file  
name specification entered.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9635E (HP-UX)  
Invalid license certificate file: file name.  
Explanation: The specified file does not contain valid license certificate  
information.  
System Action: The license registration command ignores the contents of the file.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9635E (Solaris)  
Invalid license certificate file: file name.  
Explanation: The specified file does not contain valid license certificate  
information.  
System Action: The license registration command ignores the contents of the file.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
Tivoli Storage Manager Messages  
1035  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9635E (Windows NT)  
Invalid license certificate file: file name.  
Explanation: The specified file does not contain valid license certificate  
information.  
System Action: The license registration command ignores the contents of the file.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9636E (HP-UX)  
Could not open file file name.  
Explanation: The server could not open the license certificate file specified.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9636E (Solaris)  
Could not open file file name.  
Explanation: The server could not open the license certificate file specified.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
ANR9636E (Windows NT)  
Could not open file file name.  
Explanation: The server could not open the license certificate file specified.  
System Action: The license registration command fails.  
User Response: Examine the file specification entered, including wildcard  
characters, to determine if it names the license certificate file(s) you intended to use.  
If an error is found, re-try the command with the corrected specification. If an error  
cannot be found, contact your service representative.  
1036  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9637E (HP-UX)  
Cannot access node license lock file: file name.  
Explanation: The server was not able to access the specified file. The node lock  
file contains licensing information for the server.  
System Action: The license function fails.  
User Response: Examine the file specification displayed and ensure that the file  
attributes will allow the server to access the file. The location of the file is either in  
the directory from which the server is started, or in the directory specified by the  
DSMSERV_DIR environment variable. Re-specify the DSMSERV_DIR environment  
variable if this specification is in error. Also ensure that there is sufficient space on  
the drive specified for the file. If the problem persists after these corrections have  
been made, contact your service representative.  
ANR9637E (Solaris)  
Cannot access node license lock file: file name.  
Explanation: The server was not able to access the specified file. The node lock  
file contains licensing information for the server.  
System Action: The license function fails.  
User Response: Examine the file specification displayed and ensure that the file  
attributes will allow the server to access the file. The location of the file is either in  
the directory from which the server is started, or in the directory specified by the  
DSMSERV_DIR environment variable. Re-specify the DSMSERV-DIR environment  
variable if this specification is in error. Also ensure that there is sufficient space on  
the drive specified for the file. If the problem persists after these corrections have  
been made, contact your service representative.  
ANR9637E (Windows NT)  
Cannot access node license lock file: file name.  
Explanation: The server was not able to access the specified file. The node lock  
file contains licensing information for the server.  
System Action: The license function fails.  
User Response: Examine the file specification displayed and ensure that the file  
attributes will allow the server to access the file. The location of the file is either in  
the directory from which the server is started, or in the directory specified by the  
DSMSERV_DIR environment variable. Re-specify the DSMSER-DIR environment  
variable if this specification is in error. Also ensure that there is sufficient space on  
the drive specified for the file. If the problem persists after these corrections have  
been made, contact your service representative.  
Tivoli Storage Manager Messages  
1037  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9638W (HP-UX)  
License registration is not supported on this server.  
Explanation: The REGISTER LICENSE command fails because the license  
authorization module cannot be found.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: The license authorization file is required for formal licensing for  
the HP-UX server. The file is delivered when the server is purchased, but it is not  
available in the product service stream or with demonstration copies of the server. If  
you have purchased the server, contact your service representative for assistance in  
resolving this problem.  
ANR9638W (Solaris)  
License registration is not supported on this server.  
Explanation: The REGISTER LICENSE command fails because the license  
authorization module cannot be found.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: The license authorization file is required for formal licensing for  
the Sun Solaris server. The file is delivered when the server is purchased, but it is  
not available in the product service stream or with demonstration copies of the  
server. If you have purchased the server, contact your service representative for  
assistance in resolving this problem.  
ANR9638W (Windows NT)  
License registration is not supported on this server.  
Explanation: The REGISTER LICENSE command fails because the license  
authorization module cannot be found.  
System Action: Server operation continues; licensing terms are not changed by the  
REGISTER LICENSE command.  
User Response: The license authorization file is required for formal licensing for  
the Windows NT server. The file is delivered when the product is purchased, but it  
is not available in the product service stream or with demonstration copies of the  
server. If you have purchased the server, contact your service representative for  
assistance in resolving this problem.  
1038  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9639W (HP-UX)  
Unable to load shared library shared library.  
Explanation: The server module is unable to load the indicated shared library.  
System Action: Server operation continues, but the function that requires the  
shared library will be inoperative.  
User Response: Ensure that the shared library is accessible. If this is an evaluation  
copy of the server, then this message is normal for the DSMREG library, since the  
library is only provided with purchased servers. The server licensing will assume  
Try and Buymode with sample licensed options for a period of time.  
ANR9639W (Solaris)  
Unable to load Shared License File shared library.  
Explanation: The server was unable to loaded the shared library.  
System Action: Server operation continues, but functions that require the shared  
library will be inoperative.  
User Response: Make sure the shared library is accessible/readable. This message  
is normal for those servers in the Try and Buy mode.  
ANR9640E (HP-UX)  
Unable to load procedure address from shared library shared library.  
Explanation: The server module is unable to load the address of a routine in the  
indicated shared library.  
System Action: Server operation continues, but the function that requires the  
shared library will be inoperative.  
User Response: Ensure that the shared library is accessible. If the problem  
persists, contact you service representative.  
ANR9640E (Solaris)  
Unable to load procedure address from shared library shared library license  
module.  
Explanation: The server module is unable to load the address of a routine in the  
indicated shared library for license loading.  
System Action: Server operation continues, but the function that requires the  
shared library will be inoperative.  
User Response: Ensure that the shared library is accessible. If the problem  
persists, contact your customer service representative.  
Tivoli Storage Manager Messages  
1039  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9641W (HP-UX)  
One or more EVALUATION LICENSES will expire on expiration date.  
Explanation: Although you are running with a purchased version of the server,  
there are one or more licenses registered that will expire on the date specified. This  
is usually the case when you have been using evaluation licenses prior to purchasing  
the product.  
System Action: Server operation continues.  
User Response: Halt the server and erase the nodelock file in the server startup  
directory. After restarting the server, use the REGISTER LICENSE command to  
define the licensed features that you have purchased with your server. These licenses  
should NOT have an expiration date, so this message should not appear after  
re-registering the proper licenses. If this message persists, contact your service  
representative.  
ANR9641W (Solaris)  
One or more EVALUATION LICENSES will expire on expiration date.  
System Action: Server operation continues.  
User Response: Halt the server and erase the nodelock file in the server startup  
directory. After restarting the server, use the REGISTER LICENSE command to  
define the licensed features that you have purchased with your server. These licenses  
should NOT have an expiration date, so this message should not appear after  
re-registering the proper licenses. If this message persists, contact your service  
representative.  
ANR9642E (HP-UX)  
The specified license authorization code (license authorization code) is invalid.  
Explanation: The license authorization code which you entered using the  
REGISTER LICENSE command is invalid.  
System Action: No additional licenses are registered. Server operation continues.  
User Response: Obtain a valid license authorization code and try the command  
again.  
ANR9678W (Windows NT)  
file name used for server executable. A server is currently running as a service.  
Explanation: The name of the executable used when the server is running as a  
service cannot be used in the plan file.  
System Action: PREPARE uses file name identified in the message within the plan  
file and generation of the plan file continues.  
1040  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR9679W (AIX)  
command: Unable to locate file file name.  
Explanation: The specified file cannot be found. Note: PREPARE assumes that  
the volume formatting program (dsmfmt), is located in the same directory as the  
server executable file.  
System Action: PREPARE uses the following default file names in the plan file:  
For the server executable the default is /usr/tivoli/tsm/server/bin/dsmserv.  
For the volume formatting program the default is  
/usr/tivoli/tsm/server/bin/dsmfmt.  
User Response: Determine why file does not exist; create if necessary.  
ANR9679W (Windows NT)  
command: Unable to locate file file name.  
Explanation: The specified file cannot be found.  
System Action: PREPARE uses the following default file names in the plan file:  
For the server executable the default is c:\prograx1\tivoli\tsm\server\dsmserv.  
User Response: Determine why file does not exist; create if necessary.  
ANR9680W (AIX)  
command: Could not obtain AIX logical volume information for volume name  
while building stanza recovery plan stanza name.  
Explanation: This volume is defined to the server but PREPARE can not obtain  
AIX logical volume information for it from the AIX Object Data Manager (ODM).  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: This message should be preceded by another error message which  
contains the ODM error code.  
ANR9680W (HP-UX)  
command: Could not obtain logical volume information for volume name while  
building stanza recovery plan stanza name.  
Explanation: This volume is defined to the server but PREPARE can not obtain  
logical volume information for it.  
Tivoli Storage Manager Messages  
1041  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: This message should be preceded by another error message which  
contains an error code.  
ANR9680W (S/390)  
command: Catalog information cannot be obtained for file ’file name’.  
Explanation: Catalog information cannot be obtained for the file specified in the  
message. DRM does not support creation of JCL for a file that is not catalogued.  
System Action: The stanzas, where JCL is created, for this file will not contain  
volume or unit information.  
User Response: Catalog the file.  
ANR9680W (Solaris)  
command: Could not obtain logical volume information for volume name while  
building stanza recovery plan stanza name.  
Explanation: This volume is defined to the server but PREPARE can not obtain  
logical volume information for it.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: This message should be preceded by another error message which  
contains an error code.  
ANR9680W (Windows NT)  
Unable to locate path for component in registry.  
Explanation: The path to the component could not be found in the registry.  
System Action: PREPARE uses the following default path names in the plan file:  
For the components installation directory the default is  
c:\prograx1\tivoli\tsm\server\  
For the administrative command line client the default is  
c:\prograx1\tivoli\tsm\baclient\  
For the disk formatting utility the default is c:\prograx1\tivoli\tsm\utils\  
User Response: Determine why path does not exist; install components if  
necessary.  
1042  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9681W (AIX)  
command: Volume file name not found while building stanza recovery plan stanza  
name.  
Explanation: This volume is defined to the server but does not exist. The device  
class associated with the volume is DISK or the device class device type is FILE.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: Determine why the file does not exist; create it if necessary.  
ANR9681W (AS/400)  
command: Volume file name not found while building stanza recovery plan stanza  
name.  
Explanation: This volume is defined to the ADSM server but does not exist or has  
some other problem. If the file exists, the error code issued in a previous message  
can be checked to determine the problem. The device class associated with the  
volume is DISK or the device class device type is FILE.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: Determine why file does not exist or what the problem is; create  
if necessary.  
ANR9681W (S/390)  
command: Volume file name not found while building stanza recovery plan stanza  
name.  
Explanation: This volume is defined to the server but does not exist. The device  
class associated with the volume is DISK or the device class device type is FILE.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
User Response: Determine why file does not exist; create if necessary.  
ANR9681W (Windows NT)  
command: Volume file name not found while building stanza recovery plan stanza  
name.  
Explanation: This volume is defined to the server but does not exist. The device  
class associated with the volume is DISK or the device class device type is FILE.  
System Action: The entry for the volume is not included in the recovery plan  
stanza.  
Tivoli Storage Manager Messages  
1043  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Determine why file does not exist; create if necessary.  
ANR9682E (AIX) command: Generated file name too long. Length of directory or prefix 'prefix'  
plus 'name' exceeds maximum characters characters.  
Explanation: The file name generated is too long. The maximum valid length is  
shown in the message.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9682E (AS/400)  
command: Generated file name too long. Length of library or prefix ’prefix’ plus  
name’ exceeds maximum characters characters.  
Explanation: The file name generated is too long. The maximum valid length is  
shown in the message.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9682E (S/390)  
command: Generated file name too long. Length of directory or prefix ’prefix’  
plus ’name’ exceeds maximum characters characters.  
Explanation: The file name generated is too long. The maximum valid length is  
shown in the message.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
1044  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARE  
ANR9682E (Windows NT)  
command: Generated file name too long. Length of directory or prefix ’prefix’  
plus ’name’ exceeds maximum characters characters.  
Explanation: The file name generated is too long. The maximum valid length is  
shown in the message.  
System Action: The recovery plan file was not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9683E (AIX) command: Cannot generate fully qualified file name for 'name'.  
Explanation: A failure occurred expanding the specified file name.  
System Action: Recovery plan file not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9683E (AS/400)  
command: Cannot generate fully qualified file name for ’name’.  
Explanation: A failure occurred expanding the specified file name.  
System Action: Recovery plan file not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
Tivoli Storage Manager Messages  
1045  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9683W (S/390)  
command: Cannot generate fully qualified file name for ’name’. Prepare will  
substitute file name ’default name’.  
Explanation: The fully qualified name for the volume history or device  
configuration file specified in the message could not be determined. Either the  
volume history or device configuration file specified in the plan file does not exist  
or some other error has occurred.  
System Action: Recovery plan file was created using the substitute name.  
User Response: Reissue the command after the volume history or device  
configuration file has been backed up.  
ANR9683E (Windows NT)  
command: Cannot generate fully qualified file name for ’name’.  
Explanation: A failure occurred expanding the specified file name.  
System Action: Recovery plan file not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9684E (AIX) command: Cannot generate server options file name.  
Explanation: A failure occurred generating the server options file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9684E (AS/400)  
command: Cannot generate server options file name.  
Explanation: A failure occurred generating the server options file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
1046  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9684E (S/390)  
command: Cannot generate fully qualified file name for ’name’.  
Explanation: A failure occurred creating the specified file name.  
System Action: Recovery plan file not created.  
User Response: Reissue the command specifying a valid prefix. The following  
commands are used to specify the prefix:  
SET DRMPLANPREFIX  
SET DRMINSTRPREFIX  
PREPARE  
ANR9684E (Windows NT)  
command: Cannot generate server options file name.  
Explanation: A failure occurred generating the server options file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9685E (AIX) command: Cannot generate a volume history file name.  
Explanation: A failure occurred generating the volume history file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9685E (AS/400)  
command: Cannot generate a volume history file name.  
Explanation: A failure occurred generating the volume history file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9685E (S/390)  
command: Catalog information cannot be found for options file ’file name’.  
Explanation: The options file name specified in the message is not cataloged. The  
options file must be cataloged.  
System Action: The recovery plan file was not created.  
User Response: Catalog the options file.  
Tivoli Storage Manager Messages  
1047  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9685E (Windows NT)  
command: Cannot generate a volume history file name.  
Explanation: A failure occurred generating the volume history file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9686E (AIX) command: Cannot generate a device configuration file name.  
Explanation: A failure occurred generating the device configuration file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9686E (AS/400)  
command: Cannot generate a device configuration file name.  
Explanation: A failure occurred generating the device configuration file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9686E (Windows NT)  
command: Cannot generate a device configuration file name.  
Explanation: A failure occurred generating the device configuration file name.  
System Action: Recovery plan file not created.  
User Response: See accompanying messages for more information.  
ANR9690W (S/390)  
command: Cannot obtain help file name.  
Explanation: Help file name cannot be obtained. HLPAMENG will not be  
included in the START.SERVER stanza of the plan file.  
System Action: Processing continues.  
User Response: None.  
ANR9691W (S/390)  
command: Cannot obtain image file name.  
Explanation: Image file name cannot be obtained. IMAGES will not be included  
in the START.SERVER stanza of the plan file.  
1048  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing continues.  
User Response: None.  
ANR9710E  
ANR9711E  
Insufficient memory to continue operations.  
Explanation: There is not enough memory to operate the label utility program.  
System Action: The program is halted.  
User Response: Provide more memory for the program to use.  
Unrecognized argument ’argument’.  
Explanation: The specified argument is not recognized as one that is supported by  
the label utility program.  
System Action: The program is halted.  
User Response: Retry the label utility program with the correct argument syntax.  
ANR9712E  
ANR9713E  
Argument has invalid value ’argument’.  
Explanation: The value specified for the given argument is not valid.  
System Action: The program is halted.  
User Response: Retry the label utility program with the correct argument syntax.  
Only one library can be specified.  
Explanation: Only one library can be specified in the argument list for the label  
utility program.  
System Action: The program is halted.  
User Response: Retry the label utility program with the correct argument syntax.  
ANR9714E  
No drives were specified.  
Explanation: At least one drive must be specified for use by the label utility  
(DSMLABEL) program.  
System Action: The program is halted.  
User Response: Retry the label utility program with the correct argument syntax.  
Tivoli Storage Manager Messages  
1049  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9715E  
Error starting label activity for drive drive name.  
Explanation: The label utility is unable to start its activity for the given drive.  
System Action: The program is halted.  
User Response: Increase the number of allowed threads or processes in the  
system, then retry the operation.  
ANR9716E  
Device ’library name’ is not accessable, or is not recognized as a supported  
library type.  
Explanation: The device specified for the library cannot be accessed or is not  
recognized as a supported device.  
System Action: The program is halted.  
User Response: Retry the operation, specifying a valid supported library.  
ANR9717E  
Element address element address is not valid for drive ’drive name’.  
Explanation: The specified element address does not represent a valid drive  
location in the associated library.  
System Action: The program is halted.  
User Response: Retry the operation, specifying a valid element address for the  
drive.  
ANR9718E  
Device ’drive name’ is not recognized as a supported drive type.  
Explanation: The device specified for the drive is not recognized as a supported  
device.  
System Action: The program is halted.  
User Response: Retry the operation, specifying a valid supported drive.  
ANR9719E  
Too many drives were specified.  
Explanation: The number of drives specified on the command line exceeds the  
limits of the program.  
System Action: The program is halted.  
User Response: Retry the operation, specifying only up to the maximum number  
of supported drives. The program can be invoked with the -help argument to  
determine this maximum value.  
1050  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9720I  
ANR9721E  
Volume ’volume name’ was labeled successfully using drive ’drive name’.  
Explanation: The volume is successfully labeled.  
System Action: The program continues operation.  
User Response: None.  
Volume name’ is not a valid volume name.  
Explanation: The specified string is not a valid volume name.  
System Action: The program prompts for a new volume name.  
User Response: Enter a volume name that is within the length constraints for the  
media type being labeled, and which contains only alphanumeric characters.  
ANR9722I  
ANR9723I  
ANR9724I  
Insert a new volume in drive ’drive name’, then enter the name (1-maximum  
length characters) to be used for its label; or just press ENTER to quit this  
program:  
Explanation: The program prompts for a new volume to be mounted in the given  
drive so that a label can be written to it.  
System Action: The program waits for the volume name to be entered.  
User Response: Mount a new volume, then type a volume name for it and press  
ENTER; or, if you want to quit the program, press ENTER without entering a  
volume name.  
Insert side A of a new volume in drive ’drive name’, then enter the name  
(1-maximum length characters) to be used for its label; or just press ENTER to  
quit this program:  
Explanation: The program prompts for a new volume to be mounted in the given  
drive so that a label can be written to it.  
System Action: The program waits for the volume name to be entered.  
User Response: Mount side A of a new volume, then type a volume name for it  
and press ENTER; or, if you want to quit the program, press ENTER without  
entering a volume name.  
Flip the volume in drive ’drive name’ to side B, then press ENTER.  
Explanation: The program prompts for a two-sided volume to be flipped so that  
its second side can be labeled.  
System Action: The program waits for the ENTER key to be pressed.  
Tivoli Storage Manager Messages  
1051  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Flip the volume in the drive, and press ENTER.  
ANR9725E  
ANR9726E  
ANR9727E  
The volume in drive ’drive name’ is already labeled (volume name).  
Explanation: The volume in the specified drive cannot be labeled because it  
already contains a valid label with the given name.  
System Action: The volume is not labeled.  
User Response: If an overwrite of the existing label with a new label is desired,  
restart the DSMLABEL utility program by using the -overwrite argument.  
I/O error writing label for volume ’volume name’ in drive ’drive name’.  
Explanation: An I/O error occurs while attempting to write the label for the  
specified volume in the given drive.  
System Action: The volume is not labeled.  
User Response: Ensure that the volume is not write protected, the drive is  
powered on and ready, and the device parameter has the correct value.  
Media fault detected on volume ’volume name’ in drive ’drive name’.  
Explanation: A media fault condition is detected for the specified volume in the  
given drive.  
System Action: The volume is not labeled.  
User Response: Remove the volume from use, since the media is questionable. If  
the media in question requires formatting, such as an unformatted optical disk, retry  
the operation by starting the program with the '-format' argument.  
ANR9728E  
Error ejecting volume from drive ’drive name’.  
Explanation: An error occurs while ejecting the volume from the given drive.  
System Action: All further activity on the given drive is suspended.  
User Response: Ensure that the drive is in proper operating condition before  
resuming its use.  
ANR9729E  
I/O error formatting volume ’volume name’ in drive ’drive name’.  
Explanation: An I/O error occurs while attempting to format the media for the  
specified volume in the given drive.  
System Action: The volume is not labeled.  
1052  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the volume is not write protected, that the drive is  
powered on and ready, and that the media is not damaged.  
ANR9730I  
Manual intervention required for library device ’library device name’.  
Explanation: The specified library device requires manual intervention before it  
can be accessed for normal operations.  
System Action: The operation will be retried periodically until either the required  
action is performed or a timeout occurs.  
User Response: If the library has an access door, make sure it is in the closed  
position. If it has a cartridge carousel, make sure the carousel is installed.  
ANR9731I  
Insert a new volume into the entry/exit port of library ’library device name’,  
then enter the name (1-maximum length characters) to be used for its label; or  
just press ENTER to quit this program:  
Explanation: The program prompts for a new volume to be mounted in the  
entry/exit port of the given library so that a label can be written to it.  
System Action: The program waits for the volume name to be entered.  
User Response: Insert a new volume into the entry/exit port, then type a volume  
name for it and press ENTER; or, if you want to quit the program, press ENTER  
without entering a volume name.  
ANR9732I  
Insert a new volume in the entry/exit port of library ’library device name’ with  
side A facing up, then enter the name (1-maximum length characters) to be used  
for its label; or just press ENTER to quit this program:  
Explanation: The program prompts for a new volume to be mounted in the  
entry/exit port of the given library so that a label can be written to it.  
System Action: The program waits for the volume name to be entered.  
User Response: Insert a new volume into the entry/exit port, then type a volume  
name for it and press ENTER; or, if you want to quit the program, press ENTER  
without entering a volume name.  
ANR9733I  
Insert a new volume in drive ’drive name’ of library ’library device name’, then  
enter the name (1-maximum length characters) to be used for its label; or just  
press ENTER to quit this program:  
Explanation: The program prompts for a new volume to be mounted in the given  
drive so that a label can be written to it.  
System Action: The program waits for the volume name to be entered.  
Tivoli Storage Manager Messages  
1053  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Mount a new volume, close the library access door, and then type  
a volume name for it and press ENTER; or, if you want to quit the program, press  
ENTER without entering a volume name.  
ANR9734I  
Insert side A of a new volume in drive ’drive name’ of library ’library device  
name’, then enter the name (1-maximum length characters) to be used for its  
label; or just press ENTER to quit this program:  
Explanation: The program prompts for a new volume to be mounted in the given  
drive so that a label can be written to it.  
System Action: The program waits for the volume name to be entered.  
User Response: Mount side A of a new volume, close the library access door, and  
then type a volume name for it and press ENTER; or, if you want to quit the  
program, press ENTER without entering a volume name.  
ANR9735I  
Enter the name (1-maximum length characters) for the next volume to label in  
library ’library device name’; or just press ENTER to quit this program:  
Explanation: The program prompts for the name of the next volume to be labeled  
in the given library.  
System Action: The program waits for the volume name to be entered.  
User Response: Type the name for the next volume to be labeled and then press  
ENTER; or, if you want to quit the program, press ENTER without entering a  
volume name.  
ANR9736E  
An I/O error occurred while accessing library device ’library device name’.  
Explanation: An attempted I/O operation for the given library failed.  
System Action: If the error is noncritical, operation continues; otherwise, the  
program is halted.  
User Response: Ensure that the library device is powered on and ready, any access  
doors are closed, the device parameter has the correct value, and then retry the  
operation that was in progress when the error occurred.  
ANR9737I  
Remove the volume from drive ’drive name’ in library ’library device name’,  
then press ENTER.  
Explanation: All activity associated with the volume in the given drive is  
complete, so it should be removed.  
System Action: The program waits until the ENTER key is pressed.  
1054  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Remove the volume from the specified drive, then close the  
library access door and press ENTER.  
ANR9738I  
Remove the volume from the entry/exit port of library ’library device name’,  
then press ENTER.  
Explanation: All activity associated with the volume in the entry/exit port is  
complete, so it should be removed.  
System Action: The program waits until the ENTER key is pressed.  
User Response: Remove the volume from the entry/exit port, and press ENTER.  
ANR9739I  
Initializing library device ’library device name’.  
Explanation: The specified library device is being initialized for use by the  
labeling utility program.  
System Action: The library device is prepared for use.  
User Response: None.  
ANR9740E  
Volume ’volume name’ is not in the INSERT category.  
Explanation: The specified volume cannot be labeled because it is not in the  
library’s “insert” category. This restriction is provided as a safeguard against  
labeling volumes that are in use, and possibly destroying valid data.  
System Action: The volume is not labeled.  
User Response: If you are sure the volume contains no valid data, it can be  
removed from the library and then reinserted with the library’s convenience I/O  
station. This will cause the volume’s category code to be changed to the INSERT  
category, and thus allow the labeling operation to work.  
ANR9741E  
Drives ’drive name’ and ’drive name’ cannot use the same element address.  
Explanation: The element addresses specified for the given drives are the same.  
This is not allowed, since the element address is the only way in which the robot  
can distinguish between different drives in a SCSI library.  
System Action: The program is stopped.  
User Response: Restart the program, providing valid and unique element  
addresses. Appropriate values can be determined with the worksheets in  
Administrator’s Guide.  
Tivoli Storage Manager Messages  
1055  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9742E  
The element address for drive ’drive name’ is missing or invalid.  
Explanation: The element address value for the specified drive is omitted, or an  
illegal value has been provided.  
System Action: The program is stopped.  
User Response: Restart the program, providing a valid element address.  
Appropriate values can be determined with the worksheets in Administrator’s Guide.  
ANR9743I  
ANR9744E  
ANR9745E  
ANR9746E  
Attempting to label volume ’volume name’ using drive ’drive name’...  
Explanation: The specified volume is in the process of being labeled in the given  
drive.  
System Action: Labeling activity continues.  
User Response: None.  
Volume ’volume name’ is not present in library ’library name’.  
Explanation: The specified volume is not present in the given library, so it cannot  
be labeled.  
System Action: Labeling activity continues for other volumes.  
User Response: Insert the volume into the library, then retry the operation.  
Only one trace argument is allowed.  
Explanation: More than one trace argument has been encountered, but only one is  
allowed.  
System Action: The program is halted.  
User Response: Retry the program, specifying at most one trace argument.  
Unable to open trace file ’file name’.  
Explanation: An error occurs while opening the specified file for writing trace  
data.  
System Action: The program is halted.  
User Response: Retry the program, specifying a valid file name for the trace file.  
1056  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9747I  
Unable to write to trace file.  
Explanation: An error occurs while writing data to the trace file.  
System Action: The program continues, but trace data may be lost.  
User Response: Make sure the disk that contains the trace file is not full or  
defective and then retry the operation.  
ANR9748I  
Insert a new volume into slot with element number ’slot element address’ of  
library ’library device name’, then enter the name (1-maximum length characters)  
to be used for its label; or just press ENTER to quit this program:  
Explanation: The program prompts for a new volume to be inserted into the given  
slot with the specified element number so that a label can be written to it. For the  
slot and element number diagram of your library, refer to the documentation  
provided with the current ptf level or refer to the Administrator’s Guide for your  
release and platform.  
System Action: The program waits for the volume name to be entered.  
User Response: Insert a new volume, close the library access door, type a volume  
name for it, and press ENTER; or, if you want to quit the program, press ENTER  
without entering a volume name.  
ANR9749I  
Insert a new volume into slot with element number ’slot element address’ of  
library ’library device name’ with side A facing up, then enter the name  
(1-maximum length characters) to be used for its label; or ju st press ENTER to  
quit this program:  
Explanation: The program prompts for a new volume to be inserted into the slot  
with the specified element number so that a label can be written to it. For the slot  
and element number diagram of your library, refer to the documentation provided  
with the current ptf level or refer to the Installing the Server and Administrative  
Client manual for your release and platform.  
System Action: The program waits for the volume name to be entered.  
User Response: Insert side A of a new volume, close the library access door, type  
a volume name for it, and press ENTER; or, if you want to quit the program, press  
ENTER without entering a volume name.  
ANR9750I  
Remove the volume from slot with element number ’slot element address’ in  
library ’library device name’, then press ENTER.  
Explanation: All activity associated with the volume in the given slot with the  
specified element number is complete, so it should be removed. For the slot and  
Tivoli Storage Manager Messages  
1057  
Download from Www.Somanuals.com. All Manuals Search And Download.  
element number diagram of your library, refer to the documentation provided with  
the current ptf level or refer to the Administrator’s Guide for your release and  
platform.  
System Action: The program waits until the ENTER key is pressed.  
User Response: Remove the volume from the specified slot, close the library  
access door, and press ENTER.  
ANR9751E  
The volume in drive ’drive name’ is not compatible with the drive.  
Explanation: The volume cannot be used in the drive. It is most likely an  
outdated media type that the drive cannot write.  
System Action: The volume is not labeled.  
User Response: Remove the volume; replace it with a different type known to  
work in the drive, or press ENTER to end the program.  
ANR9752E  
Could not access drive ’drive name’. It may be in use by another application.  
Explanation: The specified drive cannot be accessed.  
System Action: The program is halted.  
User Response: Ensure that the drive name is correct and the device is not in use  
by another application, then retry the operation.  
ANR9753E  
Skipping slot element address ’slot element address’, which has no barcode.  
Explanation: The cartridge in the indicated slot will not be labeled, since it does  
not have a valid barcode.  
System Action: The program attempts to label the next cartridge.  
User Response: Examine the cartridge to see if it has a barcode. Add a barcode if  
required.  
ANR9754I  
Barcode of element slot element address, ’hardware barcode string’, exceeds  
maximum length characters in length.  
Explanation: A barcode is encountered that was longer than a valid volume name.  
System Action: The barcode is not considered valid and will not be used for the  
server process.  
User Response: Replace the cartridge’s barcode with one that is supported by the  
library and whose number of characters does not exceed the maximum length.  
1058  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9755E  
There are no barcodes available.  
Explanation: The hardware did not return any valid barcode data for any  
cartridge.  
System Action: The program terminates without attempting to label any cartridges.  
User Response: Make sure the hardware supports barcodes, or that barcode labels  
have been affixed to the cartridges.  
ANR9756I  
No volumes were found.  
Explanation: No volumes are found in the library. This means that in a 349x ATL,  
no volumes were found in the insert category (xFF00), and that in a SCSI  
autochanger, no cartridges were loaded into the library.  
System Action: The program terminates normally.  
User Response: Insert cartridges into the library. For a 349x ATL, this may  
involve changing the category of previously inserted cartridges to be relabeled.  
ANR9757E  
ACS drive id ACS drive id is not valid for drive ’drive name’.  
Explanation: The specified ACS drive id does not represent a valid drive location  
in the associated library.  
System Action: The program is halted.  
User Response: Retry the operation, specifying a valid drive id for the drive.  
ANR9758W  
Error mounting volume ’volume name’.  
Explanation: An error occurs while mounting the volume to the drive. This may  
not be an error since the volume or drive maybe in use or locked in a shared  
environment.  
System Action: The specified volume is bypassed for labeling.  
User Response: Ensure that the volume is not locked or in use if label is required.  
ANR9759E  
unsuccessful ACSAPI response, status=acs status.  
Explanation: The ACSLS library api responded with an unsuccessful status as  
indicated.  
System Action: Depends on the ACS api for labeling, the process may continue as  
the error may not be a problem.  
User Response: If the label process terminates, contact your ACS System  
Administrator and perform ACSLS library problem determination.  
Tivoli Storage Manager Messages  
1059  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9760I  
Wait and monitor the ACSSA console message to remove volume volume id  
from CAP.  
Explanation: The specified volume is about to put into CAP for removal. Monitor  
the ACSSA console and removed the volume after it has been placed into the CAP  
as indicated in the ACSSA message.  
System Action: None.  
User Response: Monitor the ACSSA console and wait.  
ANR9773E  
Hardware configuration error in library library name: number of drives drives,  
number of storage slots storage slots.  
Explanation: The library device retuned a count of zero for either the drives or  
the slots. The drives may have not yet been configured to the operating system, or  
to the library. The library must have at least one drive and multiple slots when  
properly configured in order to be defined to the server.  
System Action: The operation fails.  
User Response: Configure the drives to the operating system, and reinitialize the  
library.  
ANR9774W  
Volume volume name should be freed of data as soon as possible.  
Explanation: The server has received an indication from the 3995 that the  
indicated volume is out of spare sectors for re-allocation. Spare sectors are reserved  
to take the place of sectors that experience I/O problems. The re-allocation can take  
place on either a read or write.  
System Action: The indicated volume is marked read-only by the server.  
User Response: A MOVE DATA command should be used as soon as possible to  
move the data from this cartridge to other cartridges in the library. This cartridge  
should NOT be marked read-write again through the UPDATE VOLUME command.  
ANR9775E  
Error while writing on volume volume name (RC=internal code).  
Explanation: An I/O error has occurred while writing on the specified volume.  
System Action: The operation fails.  
User Response: Ensure that the 3995 volume is accessible and that the media is  
usable. Diagnostics may have to be run on the 3995 with the specified volume. If  
the problem persists, contact your service representative and provide the internal  
code values from this message. The internal code is returned to the server from the  
OS/2 operating system.  
1060  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9776I  
File file name is being erased and deleted. Data erasure may take several  
minutes.  
Explanation: A file is being deleted from an optical library cartridge. The file is  
deleted when a LAN3995 device class volume is deleted. File deletion includes  
erasure of data. The erasure process can take several minutes to complete.  
System Action: The operation continues.  
User Response: None.  
ANR9778E  
Unable to establish a communication session with either the primary library  
manager or the secondary library manager.  
Explanation: The requested operation required that a communication session be  
established with a library manager. Both library managers were found to be  
unavailable at this time.  
System Action: None.  
User Response: Verify the primary or secondary library manager is up and  
operational. Once the server is verified to be operational, retry the operation.  
ANR9779E  
Unable to acquire a drive for volume volume name from the library manager.  
Explanation: The library manager was unable to assign a drive to the library  
client. There are a couple of situations that can cause this error.  
All drives are currently allocated to other library clients or the library manager.  
The request for a specific drive can not be satified. This can occur if a drive on  
the library client side is marked offline or is currently busy with another  
process.  
A communication error occured during the request to mount a volume.  
The requested volume was not present in the library manager’s inventory  
System Action: None.  
User Response: Verify that a drive is available on the library manager side and the  
drive is currently not busy or marked offline on the library client. Set the mount  
retention on the device class on the library manager and the library clients to a  
lower value. Using a lower mount retention value can free up drives.  
ANR9780E  
Volume volume name is not mounted in drive from the library drive name.  
Explanation: A communication error occured while dismount the volume.  
System Action: None.  
Tivoli Storage Manager Messages  
1061  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Verify the library manager is up and operational. Verify that the  
library manager and library client can communicate using command routing.  
ANR9781E  
Volser volume name was not found to be mounted on the library manager.  
Explanation: According to the library manager the requested volume is no longer  
mounted. The can occured if the library manager forced the volume to be  
dismounted because of a communication error.  
System Action: None.  
User Response: Verify that the volume has been dismounted.  
ANR9782E  
Primary Library Manager primary library manager name is NOT defined as a  
server.  
Explanation: The primary library manager server has not be defined to this server.  
System Action: None.  
User Response: Define the server to this server using the DEFINE SERVER  
command.  
ANR9783E  
Primary Library Manager does not contain a valid value.  
Explanation: The primary library manager server has not be defined to this server.  
System Action: None.  
User Response: Define the server to this server using the DEFINE SERVER  
command.  
ANR9784E  
Secondary Library Manager secondary library manager name is NOT defined as  
a server.  
Explanation: The secondary library manager server name has not be defined to  
this server.  
System Action: None.  
User Response: Define the server to this server using the DEFINE SERVER  
command.  
ANR9785E  
Drive drive name, is not defined on the library manager.  
Explanation: A drive is being defined that does not exist or is being managed by  
the library manager.  
System Action: None.  
1062  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Verify drive name with the library manager.  
ANR9786E  
A communication error has occured. Operation ending.  
Explanation: A communication error occured.  
System Action: None.  
User Response: Verify the library manager is up and operational. Verify that the  
library manager and library client can communicate using command routing.  
ANR9787E  
The owner name specified is not defined to this server.  
Explanation: A command was issues specifing a ownership of a volume. The  
name of the owner given was not defined to this server.  
System Action: None.  
User Response: Define the server to this server using the DEFINE SERVER  
command.  
ANR9788E  
ANR9789E  
ANR9790W  
Command: Library library name is not defined - the primary library manager  
not defined.  
Explanation: The designated library is not defined because the primary library  
manager is not defined as a server to this server.  
System Action: The command is not processed.  
User Response: Define the server to this server using the DEFINE SERVER  
command.  
Command: Library library name is not defined - the secondary library manager  
not defined.  
Explanation: The designated library is not defined because the secondary library  
manager is not defined as a server to this server.  
System Action: The command is not processed.  
User Response: Define the server to this server using the DEFINE SERVER  
command.  
Request to mount volume Volume Name for library client Library Client Name  
failed.  
Explanation: A library client requested a volume to be mount by the library  
manager, which inturn failed.  
Tivoli Storage Manager Messages  
1063  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: None.  
User Response: Verify the status of all drives are currently online and not in use  
by other library clients or the library manager itself. Free up drive resources as  
needed.  
ANR9791I  
Volume Volume Name in library Library Name ownership is changing from  
Current volume owner to New Volume owner.  
Explanation: A library client requested a volume to be mount by the library  
manager, which inturn failed.  
System Action: None.  
User Response: Verify the status of all drives are currently online and not in use  
by other library clients or the library manager itself. Free up drive resources as  
needed.  
ANR9792E  
Library Library Name on library manager Library Manager Name is currently  
not being shared.  
Explanation: A define library command attempted to define a shared library that  
was not being shared by the library manager.  
System Action: None.  
User Response: Verify the library on the library manager is being shared. If the  
library is not being shared, update the library shared status to yes.  
ANR9793I  
process name in library library name- CANCEL PENDING.  
Explanation: In response to a QUERY PROCESS command, this message  
displays the status for a process on the server. The command was started, but the  
process was canceled by an administrator.  
System Action: The background process operation is being terminated.  
User Response: None.  
ANR9794E  
Unable to load the RSM dynamic link library dynamic link library.  
Explanation: The server module is unable to load the indicated dynamic link  
library.  
System Action: Server operation continues, but the function that requires the  
dynamic link library will be inoperative.  
User Response: Ensure that the installed Windows version supports RSM. Ensure  
that the Removable Storage Manager is installed and the system DLL is accessible.  
1064  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9801I (Windows NT)  
ANR9801: Ready for operations.  
Explanation: The device driver has successfully initialized and is ready to accept  
requests from the server.  
System Action: Processing continues.  
User Response: None.  
ANR9803W (Windows NT)  
ANR9803: ERROR! Insufficient free memory to initialize driver.  
Explanation: The server device driver is unable to initialize due to an inability to  
acquire dynamic storage.  
System Action: Processing continues. The device driver is not available to process  
requests from the server.  
User Response: For minimum storage requirements, refer to Licensed Program  
Specifications/2. You must have sufficient memory in your system to initialize  
Windows NT and the device drivers you want to use.  
ANR9810I (Windows NT)  
ANR9810: SCSI Tape Device Driver Initializing...  
Explanation: The server SCSI tape device driver has been invoked by the system  
and is initializing.  
System Action: Processing continues.  
User Response: None.  
ANR9820I (Windows NT)  
ANR9820: SCSI Autochanger Device Driver Initializing...  
Explanation: The server SCSI automatic changer device driver has been invoked  
by the system and is initializing.  
System Action: Processing continues.  
User Response: None.  
ANR9900W (AIX)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: The server detects an error while trying to open the accounting file.  
System Action: Server processing continues.  
Tivoli Storage Manager Messages  
1065  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9900W (AS/400)  
Attention -- Accounting file could not be opened for write: filespec.  
Explanation: ADSM detects an error while trying to open the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the  
accounting file is not marked as read-only.  
ANR9900W (HP-UX)  
Attention -- Accounting records could not be written to the file: file name.  
Explanation: The server detects an error while trying to open the accounting file.  
System Action: Server processing continues, but no accounting records are written.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9900W (Solaris)  
Attention -- Accounting records could not be written to the file: file name.  
Explanation: The server detects an error while trying to open the accounting file.  
System Action: Server processing continues, but no accounting records are written.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9900W (Windows NT)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: The server detects an error while trying to open the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9901W (AIX)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: The server detects an error while trying to write an accounting  
record.  
1066  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9901W (AS/400)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: ADSM detects an error while trying to write an accounting record.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the  
accounting file is not marked as read-only.  
ANR9901W (HP-UX)  
Attention -- Accounting records could not be written to the file: file name.  
Explanation: The server detects an error while trying to write an accounting  
record.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9901W (Solaris)  
Attention -- Accounting records could not be written to the file: file name.  
Explanation: The server detects an error while trying to write an accounting  
record.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9901W (Windows NT)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: The server detects an error while trying to write an accounting  
record.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
Tivoli Storage Manager Messages  
1067  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9902W (AIX)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: The server detects an error while trying to close the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the  
accounting file is not marked as read-only.  
ANR9902W (AS/400)  
Attention -- Cannot close accounting file: filespec. Records not written to file.  
Explanation: ADSM detects an error while trying to close the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the  
accounting file is not marked as read-only.  
ANR9902W (HP-UX)  
Attention -- Accounting records could not be written to the file: file name.  
Explanation: The server detects an error while trying to close the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9902W (Solaris)  
Attention -- Accounting records could not be written to the file: file name.  
Explanation: The server detects an error while trying to close the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
ANR9902W (Windows NT)  
Attention -- Accounting records could not be written to the file: filespec.  
Explanation: The server detects an error while trying to close the accounting file.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the accounting  
file is not marked as read-only.  
1068  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9950W (AS/400)  
Attention -- License option could not be written to the file: filespec.  
Explanation: ADSM detects an error while trying to write to the options file.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the options  
file is not marked as read-only.  
ANR9950W (S/390)  
Warning -- License option could not be written to the file: filespec.  
Explanation: The server detects an error while trying to write to the options file.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the options  
file is not marked as read-only.  
ANR9950W (Windows NT)  
Attention -- License option could not be written to the file: filespec.  
Explanation: The server detects an error while trying to write to the options file.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the options file  
is not marked as read-only.  
ANR9951W (S/390)  
Warning -- License option could not be written to the file: filespec.  
Explanation: The server detects an error while trying to write to the options file.  
System Action: Server processing continues.  
User Response: Ensure that sufficient disk space is available and that the options  
file is not marked as read-only.  
ANR9951W (Windows NT)  
Attention -- License option could not be written to the file: filespec.  
Explanation: The server detects an error while trying to close the options file.  
System Action: Server processing continues.  
User Response: Ensure that there is sufficient disk space and that the options file  
is not marked as read-only.  
Tivoli Storage Manager Messages  
1069  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9952E (AS/400)  
Command: Invalid value specified for licensed storage capacity - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid value.  
ANR9952E (S/390)  
Command: Invalid value specified for licensed storage capacity - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Reissue the command using a valid value.  
ANR9952E (Windows NT)  
Command: Invalid value specified for licensed storage capacity - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command using a valid value.  
ANR9953E (AS/400)  
Command: Invalid value specified for number of licensed clients - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command and specify a valid value.  
ANR9953E (S/390)  
Command: Invalid value specified for number of licensed clients - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Reissue the command using a valid value.  
1070  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9953E (Windows NT)  
Command: Invalid value specified for number of licensed clients - value.  
Explanation: The specified command has been issued with an invalid value.  
System Action: Server operation continues, but the command is not processed.  
User Response: Issue the command using a valid value.  
ANR9954E (AS/400)  
REGISTER LICENSE is not a valid command for this release.  
Explanation: The REGISTER LICENSE command does not apply to the V3R1  
operating system.  
System Action: Server operation continues, but the command is not processed.  
User Response: Add additional licenses by using the ADDLICKEY command.  
ANR9954S (S/390)  
The server is not licensed for use on this system.  
Explanation: DFSMS/MVS Feature server is not defined as licensed for this  
system to use in SYS1.PARMLIB member IGDDFPKG.  
System Action: The server operation ends.  
User Response: If you are licensed to use the server, update the IGDDFPKG  
member in SYS1.PARMLIB to set the correct value that enables the server. Either  
start task DFSMSPKG or reIPL.  
ANR9955I (AS/400)  
An EVALUATION LICENSE for number of clients clients will expire on  
expiration date.  
Explanation: The ADSM/400 Server is distributed with an evaluation license for  
client node connections. If no formal license is found for server and the evaluation  
period has not lapsed, this message is displayed each time the server checks the  
server license terms.  
System Action: The number of client connections specified are used to determine  
if the server is in compliance with license terms.  
User Response: If you are interested in using the ADSM server, please contact  
your service representative to obtain formal licenses for the server before the  
evaluation period has elapsed. Without formal licenses, clients cannot back up or  
archive files, and new clients cannot be defined after the expiration date shown.  
Tivoli Storage Manager Messages  
1071  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9955W (Windows NT)  
Unable to load dynamic link library dynamic link library.  
Explanation: The server module is unable to load the indicated dynamic link  
library.  
System Action: Server operation continues, but the function that requires the  
dynamic link library will be inoperative.  
User Response: Ensure that the dynamic link library directories are accessible. If  
this is an evaluation copy of the server, then this message is normal for the  
DSMREG library, since the library is only provided with purchased NT servers. The  
server licensing will assume Try and Buymode with sample licensed options for a  
period of time.  
ANR9956I (AS/400)  
An EVALUATION LICENSE has expired.  
Explanation: The ADSM/400 Server is distributed with an evaluation license. The  
evaluation license has expired.  
System Action: Server continues with the default license terms.  
User Response: If you are interested in using the ADSM server, please contact  
your service representative to obtain formal licenses. Without formal licenses, clients  
cannot back up or archive files, and new clients cannot be defined after the  
expiration date shown.  
ANR9956E (Windows NT)  
Unable to load procedure address from dynamic link library dynamic link  
library.  
Explanation: The server module is unable to load the address of a routine in the  
indicated dynamic link library.  
System Action: Server operation continues, but the function that requires the  
dynamic link library will be inoperative.  
User Response: Ensure that the dynamic link library directories are accessible. If  
the problem persists, contact you service representative.  
ANR9957E (AS/400)  
License object validation failed.  
Explanation: License object failed the validation.  
System Action: Server operation continues.  
1072  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Contact your service representative if you have valid formal  
licenses.  
ANR9957W (Windows NT)  
One or more EVALUATION LICENSES will expire on expiration date.  
Explanation: Although you are running with a purchased version of the server,  
there are one or more licenses registered that will expire on the date specified. This  
i usually the case when you have been using evaluation licenses prior to purchasing  
the server for NT.  
System Action: Server operation continues.  
User Response: Halt the server and erase the nodelock file in the server startup  
directory. After restarting the server, use the REGISTER LICENSE command to  
define the licensed features that you have purchased with your NT server. These  
licenses should NOT have an expiration date, so this message should not appear  
after re-registering the proper licenses. If this message persists, contact your service  
representative.  
ANR9958I (AS/400)  
An EVALUATION LICENSE for all device features will expire on expiration  
date.  
Explanation: The ADSM/400 Server is distributed with an evaluation license for  
device support modules. If no formal license is found for server and the evaluation  
period has not lapsed, this message is displayed each time the server checks the  
server license terms.  
System Action: The device support module specified is used to determine if the  
server is in compliance with license terms with respect to the devices in use by the  
server.  
User Response: If you are interested in using the ADSM server, please contact  
your service representative to obtain formal licenses for the server before the  
evaluation period has elapsed. Without formal licenses, certain devices will not be  
accessible by the ADSM server after the expiration date shown.  
ANR9958W (Windows NT)  
Node entry node name was removed from this server’s definition in Active  
Directory.  
Explanation: In response to a REMOVE NODE command, the requested  
backup-archive node has been removed from this server’s definition in Active  
Directory.  
System Action: None.  
Tivoli Storage Manager Messages  
1073  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANR9959I (AS/400)  
An EVALUATION LICENSE for support of space managed clients will expire  
on expiration date.  
Explanation: The ADSM/400 Server is distributed with an evaluation license for  
space management client support. If no formal license is found for server and the  
evaluation period has not lapsed, this message is displayed each time the server  
checks the server license terms.  
System Action: The server space-managed client support license allows clients to  
utilize the server for storing files migrated during space management. The server  
checks the license when files are migrated to the server from client nodes to ensure  
that the server is licensed to perform this function.  
User Response: If you are interested in using the ADSM server, please contact  
your service representative to obtain formal licenses for the server before the  
evaluation period has elapsed. Without formal licenses, the server will not support  
space managed clients after the expiration date shown.  
ANR9959W (Windows NT)  
Node entry node name was not removed from this server’s definition in Active  
Directory.  
Explanation: In response to a REMOVE NODE command, the requested  
backup-archive node has not been removed from this server’s definition in Active  
Directory.  
System Action: None.  
User Response: To remove a node entry in the Active Directory, the option  
adunregisterhas to be set to yesin the server options file. A domain controller  
must also be available. The Active Directory Configuration wizard can be used to  
manually update the server definition.  
ANR9960E (AS/400)  
License registration is not supported on this server.  
Explanation: The REGISTER LICENSE command fails because the license  
authorization is not found.  
System Action: Server operation continues, but the command is not processed.  
Licensing terms are not changed by the command.  
User Response: The license authorization file is required for formal licensing for  
the server. If you have purchased the ADSM server, contact your service  
representative for assistance in resolving this problem.  
1074  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANR9960W (Windows NT)  
Node entry node name has been added to this server’s definition in Active  
Directory.  
Explanation: The requested backup-archive node entry has been added to this  
server’s definition in Active Directory in response to a REGISTER NODE  
command.  
System Action: None.  
User Response: None.  
ANR9961W (Windows NT)  
Node entry node name has not been added to this server’s definition in Active  
Directory.  
Explanation: The requested backup-archive node entry has not been added to this  
server’s definition in Active Directory in response to a REGISTER NODE  
command.  
System Action: None.  
User Response: To register a node entry in the Active Directory, the option  
adregisterhas to be set to yesin the server options file. A domain controller  
must also be available. The Active Directory Configuration wizard can be used to  
manually update the server definition.  
ANR9962W (Windows NT)  
Node entry node name was renamed in this server’s definition in Active  
Directory.  
Explanation: In response to a RENAME NODE command, the requested  
backup-archive node has been renamed to the new name shown.  
System Action: None.  
User Response: None.  
ANR9963W (Windows NT)  
Node entry node name was not renamed in this server’s definition in Active  
Directory.  
Explanation: In response to a RENAME NODE command, the requested  
backup-archive node has not been renamed.  
System Action: None.  
User Response: To Rename Node in the Active Directory, the options adregister″  
and adunregisterhave to be set to yesin the server options file. A domain  
Tivoli Storage Manager Messages  
1075  
Download from Www.Somanuals.com. All Manuals Search And Download.  
controller must also be available. The Active Directory Configuration wizard can be  
used to manually update the server definition.  
ANR9964W (Windows NT)  
Failed to access Active Directory. RC: return code  
Explanation: Could not communicate with an Active Directory server.  
System Action: Server operation continues.  
User Response: Try using the option adsetdcin the server options file to  
explicitly provide the TCP/IP address of the domain controller where Active  
Directory is located.  
ANR9965W (Windows NT)  
Could not create the inital node list in Active Directory for this server.  
Explanation: At startup the server’s registered nodes could not be added to the  
server definition in Active Directory  
System Action: Server operation continues.  
User Response: Try using the option adsetdcin the server options file to  
explicitly provide the TCP/IP address of the domain controller where Active  
Directory is located.  
ANR9966I (Windows NT)  
NodeName node name.  
Explanation: The NodeName is registered in Active Directory.  
System Action: Server operation continues.  
User Response: None.  
ANR9967I (Windows NT)  
Server server name was defined in Active Directory.  
Explanation: The server is registered in Active Directory.  
System Action: None.  
User Response: None.  
ANR9999D  
(component)(code):(text)  
Explanation: This message carries diagnostic text relating to a server process or  
algorithm. This information is intended for reporting processing exceptions and  
other non-standard situations that occur on the ADSM server. The (component),  
1076  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(code), and (text) will vary depending upon the cause of the message and the server  
process or algorithm that issues the message.  
System Action: Server processing may or may not continue depending upon the  
cause of this message.  
User Response: Examine error messages that may have been displayed before  
and/or after this message and correct any problems, if possible. If the cause of this  
message can not be determined or resolved, contact your support representative. If  
you contact your support representative, the entire text of this message should be  
reported.  
Tivoli Storage Manager Messages  
1077  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1078  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Client Events Logged to Server  
(ANE4000—4999)  
ANE4000E  
Error processing ’filespace-name’: file space does not exist  
Explanation: The specified file space (domain) is incorrect or does not exist on  
the workstation.  
System Action: Processing stopped.  
User Response: Retry the operation specifying an existing domain (drive letter or  
file system name).  
ANE4001E  
ANE4002E  
Error processing ’filespace-name’: file space not known to server  
Explanation: The number defining the correspondence between drive letter or file  
(domain name) and volume label is not known to the server.  
System Action: Processing stopped.  
User Response: Report the program error to your service representative.  
Error processing ’filespace-name’: volume label does not exist  
Explanation: The selected drive does not have a label.  
System Action: TSM is unable to do the requested operation without a drive or  
label entered.  
User Response: If the drive is a floppy drive, place a disk with a volume label in  
it and retry the operation. If the disk is a hard drive, ensure the drive has a volume  
label, and retry the operation.  
ANE4003E  
Error processing ’filespace-name’: duplicate volume label encountered  
Explanation: The selected drive has a duplicate volume label. Because TSM uses  
the volume label to keep track of backup/archive information, it cannot back up or  
archive files from a drive with a duplicate volume label.  
System Action: TSM cannot select the drive.  
User Response: If the volume needs to be available to the system, exit TSM, and  
assign a volume label to the drive. Restart TSM and retry the operation.  
Tivoli Storage Manager Messages  
1079  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANE4004E  
Error processing ’filespace namepath-namefile-name’: destination file or  
directory is write locked  
Explanation: The file or directory being restored or retrieved from the server  
cannot be written to because the destination is write locked. Another operation  
might have the file open and will not allow it to be updated.  
System Action: File skipped.  
User Response: Either determine which operation has the file write locked, or  
restore the file to another name or location.  
ANE4005E  
Error processing ’filespace namepath-namefile-name’: file not found  
Explanation: The file being processed for backup, archive or migrate no longer  
exists on the client. Another process deletes the file before it can be backed up,  
archived or migrated by TSM.  
System Action: File skipped.  
User Response: None.  
ANE4006E  
ANE4007E  
Error processing ’filespace namepath-namefile-name’: directory path not found  
Explanation: You specified an incorrect directory path.  
System Action: Processing stopped.  
User Response: Correct the syntax specified on the call and retry the operation.  
Error processing ’filespace namepath-namefile-name’: access to the object is  
denied  
Explanation: Access to the specified file or directory is denied. You tried to read  
from or write to a file and you do not have access permission for either the file or  
the directory.  
System Action: Processing stopped.  
User Response: Ensure that you specified the correct file or directory name,  
correct the permissions, or specify a new location.  
ANE4008E  
ANE4009E  
Error processing ’filespace namepath-namefile-name’: file is temporarily  
unavailable  
Explanation: File is temporarily unavailable.  
System Action: File skipped.  
User Response: Check and see if file is locked by other process. If not, retry the  
command.  
Error processing ’filespace namepath-namefile-name’: disk full condition  
Explanation: No more files can be restored or retrieved because the destination  
disk is full.  
System Action: Processing stopped.  
User Response: Free up disk space, or restore or retrieve the file to another disk.  
1080  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANE4010E  
ANE4011E  
Error processing ’filespace namepath-namefile-name’: stale NFS handle  
Explanation: An NFS file system becomes stale.  
System Action: File system skipped.  
User Response: Check the NFS mounted filesystem.  
Error processing ’filespace namepath-namefile-name’: no file handles available  
Explanation: All file handles for your system are currently in use. No more are  
available.  
System Action: Processing stopped.  
User Response: Either free some file handles by ending other processes, or modify  
your system setup to allow for more files to be open at the same time.  
ANE4012E  
ANE4013E  
Error processing ’filespace namepath-namefile-name’: file already exists  
Explanation: The file being restored or retrieved exists.  
System Action: File is replaced or skipped depending on client options.  
User Response: None.  
Error processing ’filespace namepath-namefile-name’: invalid file handle  
Explanation: An internal system error occurred. A file operation failed because an  
invalid file handle was passed.  
System Action: Processing stopped.  
User Response: Report the problem to your system administrator, and then retry  
the operation.  
ANE4014E  
Error processing ’filespace namepath-namefile-name’: unknown system error  
(error-code) encountered. Program ending.  
Explanation: An unknown and unexpected error-code occurred within the client  
program. This is a programming failure and the client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your  
administrator.  
ANE4015E  
Error processing ’filespace namepath-namefile-name’: unexpected error  
(error-code) encountered  
Explanation: An unexpected error occurred. This might be a low-level system or  
communication error that TSM cannot handle or recover from.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, determine where  
the problem exists. See your system administrator for further help.  
Tivoli Storage Manager Messages  
1081  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANE4016E  
Error processing ’filespace namepath-namefile-name’: file is being executed;  
write permission denied  
Explanation: The current file cannot be opened to write to because it is currently  
being run by another operation.  
System Action: File skipped.  
User Response: Stop the operation that is running the file and retry the operation,  
or restore or retrieve the file to a different name or directory.  
ANE4017E  
Error processing ’filespace namepath-namefile-name’: too many symbolic links  
were detected while resolving name  
Explanation: While trying to resolve the file name, too many symbolic links were  
found.  
System Action: File skipped.  
User Response: Ensure that you do not have a looping symbolic link for the file.  
ANE4018E  
ANE4019E  
Error processing ’filespace namepath-namefile-name’: file name too long  
Explanation: The file name specified is too long to be handled by TSM.  
System Action: File is skipped.  
User Response: See the appropriate Using the Backup-Archive Client book for the  
particular operating system, for the file names that are handled by TSM.  
Error processing ’filespace namepath-namefile-name’: file system is locked by  
system  
Explanation: File system cannot be accessed because it is locked by the system.  
System Action: TSM cannot complete the operation.  
User Response: See your system administrator.  
ANE4020E  
ANE4021E  
Error processing ’filespace namepath-namefile-name’: format unknown  
Explanation: TSM tried to restore or retrieve a file, but it had an unknown format.  
System Action: File skipped.  
User Response: See your system administrator.  
Error processing ’filespace namepath-namefile-name’: file system not ready  
Explanation: The file system/drive was not ready for access.  
System Action: Processing stopped.  
User Response: Ensure that the drive is available to TSM, and then retry the  
operation.  
ANE4022E  
Error processing ’filespace namepath-namefile-name’: file system is invalid  
Explanation: The drive was not available for access. A directory exists that does  
not have either a '.' or '..' entry.  
System Action: Processing stopped.  
1082  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that the drive is operational, and then retry the operation.  
If unsuccessful, have your service representative check the error log.  
ANE4023E  
Error processing ’filespace namepath-namefile-name’: file input/output error  
Explanation: An error was found while reading from or writing to the file.  
System Action: File skipped.  
User Response: Check your system to ensure that it is operating properly. For  
OS/2, run CHKDSK /F for the failing drive which can be found in dsmerror.log.  
ANE4024E  
ANE4025E  
Error processing ’filespace namepath-namefile-name’: file write error  
Explanation: An error was found while writing to the file.  
System Action: File skipped.  
User Response: Check your system to ensure that it is operating properly.  
Error processing ’filespace namepath-namefile-name’: file exceeds user or system  
file limit  
Explanation: A file being restored or retrieved exceeds system set limits for this  
user.  
System Action: File skipped.  
User Response: Ensure that the system limits are set properly.  
ANE4026W  
ANE4027S  
ANE4028E  
Error processing ’filespace namepath-namefile-name’: size of ’file-size’ exceeded  
the maximum file size limit on your system  
Explanation: You tried to restore or retrieve a file that has exceeded the maximum  
file size limitation on your system.  
System Action: TSM cannot restore or retrieve the file.  
User Response: Restore or retrieve this file on a system that supports the file size.  
See your system administrator.  
Error processing ’filespace namepath-namefile-name’: internal program message  
value’ encountered  
Explanation: An unexpected catastrophic program failure occurred, indicated by  
value.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your system  
administrator or service representative.  
Error processing ’filespace namepath-namefile-name’: cannot create file/directory  
entry  
Explanation: The directory path for files being restored or retrieved cannot be  
created.  
System Action: File skipped.  
Tivoli Storage Manager Messages  
1083  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that you have the proper authorization to create the  
directory for file being restored or retrieved.  
ANE4029E  
Error processing ’filespace namepath-namefile-name’: unable to build a directory  
path; a file exists with the same name asa directory  
Explanation: TSM tried to create a directory path, but is unable to because a file  
exists that has the same name as a directory.  
System Action: Processing stopped.  
User Response: Remove the file that has the same name as the directory. Refer to  
the last restore/retrieve operation and check all directories along the path.  
ANE4030E  
ANE4031E  
Error processing ’filespace namepath-namefile-name’: disk space limit for this  
process reached  
Explanation: The disk space allocated for the client owner is full.  
System Action: Processing stopped.  
User Response: Free up disk space and retry the restore or retrieve operation.  
Error processing ’filespace namepath-namefile-name’: destination directory path  
length exceeds system maximum  
Explanation: The path name specified plus the path name in the restored file  
name combine to create a name whose length exceeds the system maximum.  
System Action: Processing stopped.  
User Response: Specify a destination path that, when combined, is less than the  
system maximum.  
ANE4032E  
ANE4033E  
Error processing ’filespace namepath-namefile-name’: file is not compressed.  
Explanation: A file that was flagged as compressed was not compressed, and the  
system failed.  
System Action: Processing stopped.  
User Response: See your system administrator to report this problem. This error is  
a system failure.  
Error processing ’filespace namepath-namefile-name’: file compressed on a  
different client machine that has more memory  
Explanation: You are trying to restore a file that was backed up and compressed  
on another client workstation that had more memory than your client workstation.  
You cannot restore this file. When the file is restored, it is expanded and your  
workstation does not have enough memory.  
System Action: TSM canceled the operation.  
User Response: Obtain a machine with more memory and retry the operation.  
1084  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANE4034E  
ANE4035W  
Error processing ’filespace namepath-namefile-name’: unknown system error  
Explanation: An unknown error occurred. This might be a low-level system or  
communication error that TSM cannot handle or recover from.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, determine where  
the problem exists. See your system administrator for further help.  
Error processing ’filespace namepath-namefile-name’: file currently unavailable  
on server.  
Explanation: You tried to restore or retrieve a file that is currently not available  
from the server.  
System Action: TSM cannot restore or retrieve the file.  
User Response: See your system administrator to determine why the file is  
unavailable and then try your operation again.  
ANE4037E  
ANE4040E  
ANE4041W  
File ’file-namefile-namefile-name’ changed during processing. File skipped.  
Explanation: The specified file-name was skipped during backup, archive, or  
migrate because it was changing during the attempt to process it.  
System Action: TSM skipped the file.  
User Response: If you want the file backed up, archived, or migrated retry the  
operation. If it fails, determine why the file is being changed. For more information  
on backing up, archiving, or migrating changing files, see your system administrator.  
Error processing ’filespace namepath-namefile-name’: file system filespace name  
has exceeded its space management quota.  
Explanation: TSM detects that the file system has exceeded its quota. No more  
data can be migrated out of this file system.  
System Action: TSM will not migrate files from this file system.  
User Response: Recall some files, or ask the system administrator to increase the  
quota for this file system.  
Error processing ’filespace namepath-namefile-name’: Out of free space or inodes  
in file system filespace name to migrate or recall.  
Explanation: The file system is full. No more free space or free inodes are  
available to be allocated for the transaction file that is needed when a file is being  
migrated or recalled.  
System Action: TSM terminates the current operation for this file system.  
User Response: Remove some files in the file system, and then run reconciliation.  
Retry the operation.  
Tivoli Storage Manager Messages  
1085  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANE4900W  
Schedule ’schedule name’ has opened a new session with the server.  
Explanation: A scheduled event ended due to a connection failure. The scheduled  
event had to be restarted outside of its normal start-up window to continue the  
operation.  
System Action: Be advised that there are multiple sessions associated with the  
scheduled event.  
User Response: None.  
ANE4999E  
Unable to log message ’message number’ to server: message too long.  
Explanation: The message text and inserts were too large to send to the server in  
the available internal buffer.  
System Action: Refer to the local client error log for more information  
User Response: None.  
1086  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III—Client Messages  
This section contains a listing of messages for the following:  
TSM administrative clients.  
Application program interface clients  
Backup–archive and Tivoli Space Manager (HSM client) workstations  
The messages are listed in numeric order.  
This section also contains Diagnosis, Modification, or Tuning Information. Some of  
these messages include information about the TSM error log that you can use when  
working with your service representative.  
Tivoli Storage Manager Messages  
1087  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1088  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Client Message Repository File  
(0100–0199)  
This section contains messages that are intended to help when  
detecting problems relating to missing messages or problems with  
the client message files.  
ANS0101  
Unable to open message repository file name.  
Explanation: The message repository file cannot be opened.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the file in your DSM_DIR is set up properly, or the  
language specified in the option file is supported. If the problem continues, see your  
system administrator for further help.  
ANS0103  
ANS0105  
ANS0106  
Error trying to read header record from message repository file name.  
Explanation: The message repository file header record cannot be obtained.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the file has not been altered from the installation. If  
the problem continues, see your system administrator for further help.  
Error trying to read index for message number from repository file name.  
Explanation: The message text for the specified message number cannot be read.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the file has not been altered from the installation. If  
the problem continues, see your system administrator for further help.  
Message index not found for message number.  
Explanation: The message repository file does not contain the message text for  
the message number.  
System Action: TSM is unable to complete the requested operation.  
Tivoli Storage Manager Messages  
1089  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User Response: Make sure the DSM_DIR is set up properly and it does not point  
to an old copy. If the problem continues, see your system administrator for further  
help.  
ANS0107  
ANS0108  
ANS0109  
Error trying to read header for message number from repository file name.  
Explanation: The message header information cannot be obtained for the message  
number in the message file.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the file has not been altered from the installation. If  
the problem continues, see your system administrator for further help.  
Error trying to read text for message number from repository file name.  
Explanation: The message text cannot be obtained for the message number in the  
message file.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the file has not been altered from the installation. If  
the problem continues, see your system administrator for further help.  
Insufficient memory for allocation of message structure.  
Explanation: There is not enough memory in your system to allocate the storage  
needed for the message text.  
System Action: TSM is unable to complete the requested operation.  
User Response: Stop TSM and restart TSM. Then retry the operation. If  
unsuccessful, close all unneeded applications and retry the operation.  
ANS0110  
ANS0111  
Unable to open error log file for output.  
Explanation: The error log cannot be opened for output.  
System Action: TSM is unable to complete the requested operation.  
User Response: Stop and restart TSM. Then retry the operation. If unsuccessful,  
make sure the file is not being locked by another application.  
Invalid default time format.  
Explanation: The default time format is incorrect.  
System Action: TSM is unable to complete the requested operation.  
User Response: Stop TSM and restart TSM. Then retry the operation. If  
unsuccessful, make sure the DSM_DIR is set up correctly and the message file has  
not been altered from the installation.  
ANS0112  
Invalid default number format.  
Explanation: The default number format is incorrect.  
System Action: TSM is unable to complete the requested operation.  
1090  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Stop TSM and restart TSM. Then retry the operation. If  
unsuccessful, make sure the DSM_DIR is set up correctly and the message file has  
not been altered from the installation.  
ANS0113  
ANS0117  
Message repository file name has an invalid control record.  
Explanation: The message repository file contains an incorrect control  
information.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the message file was not altered from the installation.  
Check DSM_DIR to make sure it is set up properly.  
Invalid default date format.  
Explanation: The default date format is incorrect.  
System Action: TSM is unable to complete the requested operation.  
User Response: Stop TSM and restart TSM. Then retry the operation. If  
unsuccessful, make sure the DSM_DIR is set up correctly and the message file has  
not been altered from the installation.  
ANS0118  
ANS0119  
Unable to open schedule log file for output.  
Explanation: The schedule log file cannot be opened for output.  
System Action: TSM is unable to complete the requested operation.  
User Response: Stop TSM and restart TSM. Then retry the operation. If  
unsuccessful, make sure the file has not been locked by another application.  
Error trying to read response string for message number from repository file  
name.  
Explanation: The response string information for the message number cannot be  
obtained from the message repository file.  
System Action: TSM is unable to complete the requested operation.  
User Response: Make sure the message file was not altered from the installation.  
Check DSM_DIR to make sure it is set up properly.  
Tivoli Storage Manager Messages  
1091  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1092  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Application Program Interface  
(0200–0479)  
ANS0200I  
Successfully done.  
Explanation: The operation successfully completed.  
System Action: None.  
User Response: None.  
ANS0201E  
Invalid parameter was found.  
Explanation: The system encountered an internal program error due to an invalid  
parameter.  
System Action: The system returns to the calling procedure.  
User Response: Ask your service representative to check the error log.  
ANS0202E  
ANS0203E  
ANS0204E  
Not authorized to restore the other node’s data.  
Explanation: The client is not authorized to restore the other node's data.  
System Action: The system returns to the calling procedure.  
User Response: Get authorization from the other node.  
The objName field has no leading directory separator.  
Explanation: The objName field does not have a leading directory separator.  
System Action: The system returns to the calling procedure.  
User Response: Correct the value for the objName.  
Wildcards are not allowed in the objName directory path.  
Explanation: Wildcards are not allowed in the objName directory path.  
System Action: The system returns to the calling procedure.  
User Response: Correct the value for the objName.  
Tivoli Storage Manager Messages  
1093  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS0205E  
ANS0206E  
ANS0207E  
Unable to open error log file.  
Explanation: The system is unable to open the error log file.  
System Action: The system returns to the calling procedure.  
User Response: Verify the DSMI_LOG value and access permission. On the  
AS/400 platform, verify the value specified for ERRORLOGNAME in the API  
options file.  
The log file cannot be written to.  
Explanation: There was an error writing to the log file.  
System Action: The system returns to the calling procedure.  
User Response: Verify the DSMI_LOG value and access permission. on the  
AS/400 platform, verify the value specified for ERRORLOGNAME in the API  
options file.  
The log file name was not specified.  
Explanation: The system is unable to open the error log file.  
System Action: The system returns to the calling procedure.  
User Response: Verify the DSMI_LOG value and access permission. On the  
AS/400 platform, verify the value specified for ERRORLOGNAME in the API  
options file.  
ANS0208E  
ANS0209E  
The TCP/IP WINSOCK.DLL file cannot be found.  
Explanation: The TCP/IP WINSOCK.DLL file cannot be found.  
System Action: Processing stopped.  
User Response: Verify your TCP/IP installation.  
An error occurred while loading a library.  
Explanation: An error occurred while loading a library. The TCP/IP DLL load  
failed.  
System Action: Processing stopped.  
User Response: Verify your TCP/IP installation.  
ANS0210E  
ANS0211E  
The TCP/IP load function failed.  
Explanation: An error occurred while locating a function. The TCP/IP load  
function failed.  
System Action: Processing stopped.  
User Response: Verify your TCP/IP installation.  
The object name pointer is NULL.  
Explanation: There is no value provided for the object name pointer.  
System Action: The system returns to the calling procedure.  
User Response: Provide an address for the dsmObjName structure.  
1094  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0212E  
ANS0213E  
ANS0214E  
ANS0215E  
ANS0216E  
ANS0217E  
ANS0218E  
The data block pointer is NULL.  
Explanation: There is no value provided for the data block pointer.  
System Action: The system returns to the calling procedure.  
User Response: Provide an address for the DataBlk structure.  
The object attribute pointer is NULL.  
Explanation: There is no value provided for the object attribute pointer.  
System Action: The system returns to the calling procedure.  
User Response: Provide an address for the ObjAttr structure.  
There is no server session information.  
Explanation: The server did not respond with the session information.  
System Action: The system returns to the calling procedure.  
User Response: Verify the server status.  
There is no server policy information.  
Explanation: The server did not respond with the policy information.  
System Action: The system returns to the calling procedure.  
User Response: Verify the server policy definitions.  
The dataBlk bufferLen value is zero.  
Explanation: The value for the dataBlk bufferLen is zero.  
System Action: The system returns to the calling procedure.  
User Response: Provide a non-zero value for the bufferLen.  
The dataBlk bufferPtr is NULL.  
Explanation: There is no value provided for the dataBlk bufferPtr.  
System Action: The system returns to the calling procedure.  
User Response: Provide an address for the bufferPtr.  
The objType is invalid.  
Explanation: The value for the objType is invalid.  
System Action: The system returns to the calling procedure.  
User Response: The value for dsmObjName.objType must be:  
DSM_OBJ_FILE or DSM_OBJ_DIRECTORY for Backup, or  
DSM_OBJ_FILE for Archive.  
ANS0219E  
The dsmEndTxn vote is invalid.  
Explanation: The dsmEndTxn vote is invalid.  
System Action: The system returns to the calling procedure.  
Tivoli Storage Manager Messages  
1095  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The vote must be DSM_VOTE_COMMIT or  
DSM_VOTE_ABORT.  
ANS0220E  
ANS0221E  
ANS0222E  
An invalid option was found during option parsing.  
Explanation: An invalid option was found.  
System Action: The system returns to the calling procedure.  
User Response: Verify the options in dsm.opt, dsm.sys, and the options string.  
Check the error log for more details about the error. on the AS/400 platform, verify  
the options in *LIB/QOPTTSM(APIOPT).  
There was an error in the TSM API internals.  
Explanation: The system encountered an error in the API internals.  
System Action: The system returns to the calling procedure.  
User Response: Shut down the process and retry the operation. Verify that any  
previous dsmInit calls were cleaned up and terminated by a dsmTerminate call. If  
the problem continues, contact your system administrator or service representative.  
The repository type is invalid.  
Explanation: The repository type is invalid.  
System Action: The system returns to the calling procedure.  
User Response: For dsmDeleteFS the repository must be one of the following:  
DSM_ARCHIVE_REP  
DSM_BACKUP_REP  
DSM_REPOS_ALL.  
ANS0223E  
ANS0224E  
Filespace name should start with the directory delimiter.  
Explanation: The filespace name is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Filespace name should start with the directory delimiter.  
The object name is either an empty string or has no leading delimiter.  
Explanation: The object name is invalid because of an empty string or there is no  
leading delimiter.  
System Action: The system returns to the calling procedure.  
User Response: Verify the format of the dsmObjName full path.  
ANS0225E  
Low level qualifier of the object name should start with the directory delimiter.  
Explanation: The low level qualifier for the object name is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Start the low level qualifier of the object name with the directory  
delimiter.  
1096  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0226E  
ANS0227E  
The object owner is invalid.  
Explanation: The object owner must be either the root user, or the object owner  
must be the same as the session owner.  
System Action: The system returns to the calling procedure.  
User Response: Verify the session owner and object owner.  
The dsmBindMC sendType is invalid.  
Explanation: The dsmBindMC sendType is invalid.  
System Action: The system returns to the calling procedure.  
User Response: The sendType must be one of the following:  
stBackup  
stArchive  
stBackupMountWait  
stArchiveMountWait  
ANS0228E  
The dsmSendObj sendType is invalid.  
Explanation: The dsmSendObj sendType is invalid.  
System Action: The system returns to the calling procedure.  
User Response: The sendType must be one of the following:  
stBackup  
stArchive  
stBackupMountWait  
stArchiveMountWait  
ANS0229E  
ANS0230E  
The dsmDeleteObj delType is invalid.  
Explanation: The dsmDeleteObj delType is invalid.  
System Action: The system returns to the calling procedure.  
User Response: The delType must be dtBackup or dtArchive.  
The query Backup objState is invalid.  
Explanation: The query Backup objState is invalid.  
System Action: The system returns to the calling procedure.  
User Response: The qryBackupData.objState must be one of the following:  
DSM_ACTIVE  
DSM_INACTIVE  
DSM_ANY_MATCH  
Tivoli Storage Manager Messages  
1097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0231E  
ANS0232E  
The management class name was not found.  
Explanation: A query or send operation is unable to find the management class  
name.  
System Action: The system returns to the calling procedure.  
User Response: Verify the management class name.  
The drive letter is not an alphabetic character.  
Explanation: The drive letter is not an alphabetic character. This return code is  
valid on Microsoft Windows or OS/2.  
System Action: The system returns to the calling procedure.  
User Response: Verify that the drive designation is an alphabetic character. The  
referenced field is dsmDosFSAttrib.driveLetter.  
ANS0233E  
ANS0234E  
ANS0235E  
ANS0236E  
The Register Filespace name is NULL.  
Explanation: There is no value provided for the Register Filespace name.  
System Action: The system returns to the calling procedure.  
User Response: Provide a filespace name on dsmRegisterFS.  
The new password value is NULL or blank.  
Explanation: There is no value provided for new password.  
System Action: The system returns to the calling procedure.  
User Response: Provide a new password on dsmChangePW.  
The old password value is NULL or blank.  
Explanation: There is no value provided for old password.  
System Action: The system returns to the calling procedure.  
User Response: Provide an old password on dsmChangePW.  
On dsmInit, the owner is not allowed when PASSWORDACCESS=generate.  
Explanation: PASSWORDACCESS=generate establishes a session with the  
current login user as the owner.  
System Action: The system returns to the calling procedure.  
User Response: When using PASSWORDACCESS=generate, set  
clientOwnerNameP to NULL.  
ANS0237E  
On dsmInit, the node is not allowed when PASSWORDACCESS=generate.  
Explanation: PASSWORDACCESS=generate establishes a session with the  
current hostname as the node.  
System Action: The system returns to the calling procedure.  
User Response: When using PASSWORDACCESS=generate, set clientNodeP to  
NULL.  
1098  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0238E  
ANS0239E  
ANS0240E  
ANS0241E  
The sequence of calls is invalid.  
Explanation: The sequence of calls is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Verify the transaction call sequence.  
On dsmSendObj, wildcards are not allowed for the objName.  
Explanation: On dsmSendObj, wildcards are not allowed for the objName.  
System Action: The system returns to the calling procedure.  
User Response: Provide a fs, hl, and ll on the dsmObjName.  
The filespace to delete/set access cannot be found.  
Explanation: The filespace to delete cannot be found.  
System Action: The system returns to the calling procedure.  
User Response: Verify the filespace name.  
On dsmSendObj, dsmDeleteObj, or dsmUpdateFS the filespace is not  
registered.  
Explanation: On dsmSendObj, dsmDeleteObj, or dsmUpdateFS, the filespace is  
not registered.  
System Action: The system returns to the calling procedure.  
User Response: Verify the filespace name.  
ANS0242W  
ANS0243E  
On dsmRegisterFS the filespace is already registered.  
Explanation: On dsmRegisterFS the filespace is already registered.  
System Action: The system returns to the calling procedure.  
User Response: Verify the filespace name.  
On dsmBeginGetData the objID is NULL.  
Explanation: On dsmBeginGetData, the objID is NULL.  
System Action: The system returns to the calling procedure.  
User Response: Verify the following:  
The dsmGetList is not NULL.  
Each objID is not NULL.  
The dsmGetList numObjId is not zero.  
ANS0244E  
On dsmInit the caller’s API version is different than the TSM library version.  
Explanation: On dsmInit the caller's API version has a higher value than the TSM  
library version.  
System Action: The system returns to the calling procedure.  
User Response: Install the latest TSM API library and trusted agent module.  
Tivoli Storage Manager Messages  
1099  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0245E  
ANS0246E  
The caller’s structure version is different than the TSM library version.  
Explanation: The caller's structure version is different than the TSM library  
version.  
System Action: The system returns to the calling procedure.  
User Response: Ensure that the stVersion field is set with the value in the header  
file. Recompile the application with the latest header files.  
Issue dsmEndTxn and then begin a new transaction session.  
Explanation: This transaction must be ended and a new one must be started due  
to one of the following reasons:  
The destination changed.  
The byte limit is exceeded  
The maximum number of objects is exceeded.  
System Action: The system returns to the calling procedure.  
User Response: Issue dsmEndTxn and start a new transaction session.  
ANS0247E  
ANS0248E  
ANS0249E  
ANS0250E  
The backup or archive object is excluded from processing.  
Explanation: The backup or archive object is excluded from processing.  
System Action: The system returns to the calling procedure.  
User Response: Verify the objName and Exclude lists.  
The backup object does not have a copy group.  
Explanation: The backup object does not have a copy group.  
System Action: The system returns to the calling procedure.  
User Response: Verify server policy definitions.  
The archive object does not have a copy group.  
Explanation: The archive object does not have a copy group.  
System Action: The system returns to the calling procedure.  
User Response: Verify server policy definitions.  
Memory used by the TSM API has been corrupted.  
Explanation: Memory used by the TSM API has been corrupted.  
System Action: The system returns to the calling procedure.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator or service representative.  
ANS0251E  
The sendObj Archive description is too long.  
Explanation: The sendObj Archive description is too long.  
System Action: The system returns to the calling procedure.  
1100  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The sndArchiveData.descr string must be less than or equal to  
DSM_MAX_DESCR_LENGTH.  
ANS0252E  
ANS0253E  
ANS0254E  
ANS0255E  
ANS0256E  
ANS0257E  
ANS0258I  
The sendObj ObjAttr.objInfo is too long.  
Explanation: The sendObj ObjAttr.objInfo is too long.  
System Action: The system returns to the calling procedure.  
User Response: The objInfo field must be less than or equal to  
DSM_MAX_OBJINFO_LENGTH.  
The sendObj dsmObjName.hl is too long.  
Explanation: The sendObj dsmObjName.hl is too long.  
System Action: The system returns to the calling procedure.  
User Response: The hl field must be less than or equal to  
DSM_MAX_HL_LENGTH.  
The dsmChangePW password is too long.  
Explanation: The dsmChangePW password is too long.  
System Action: The system returns to the calling procedure.  
User Response: The password field must be less than or equal to  
DSM_MAX_VERIFIER_LENGTH.  
The sendObj dsmObjName.fs is too long.  
Explanation: The sendObj dsmObjName.fs is too long.  
System Action: The system returns to the calling procedure.  
User Response: The fs field must be less than or equal to  
DSM_MAX_FS_LENGTH.  
The sendObj dsmObjName.ll is too long.  
Explanation: The sendObj dsmObjName.ll is too long.  
System Action: The system returns to the calling procedure.  
User Response: The ll field must be less than or equal to  
DSM_MAX_LL_LENGTH.  
On RegisterFS or UpdateFS the fsAttr’s fsInfo is too long.  
Explanation: On RegisterFS or UpdateFS the fsAttr's fsInfo is too long.  
System Action: The system returns to the calling procedure.  
User Response: The fsInfo field must be less than or equal to  
DSM_MAX_FSINFO_LENGTH.  
On dsmGetNextQObj or dsmGetData there is more available data.  
Explanation: On dsmGetNextQObj or dsmGetData there is more available data.  
System Action: The system returns to the calling procedure.  
Tivoli Storage Manager Messages  
1101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Call the function again.  
ANS0259E  
ANS0260E  
The dataBlk buffer is too small for the query response.  
Explanation: The dataBlk buffer is too small for the query response.  
System Action: The system returns to the calling procedure.  
User Response: On dsmGetNextQObj ensure that the dataBlk buffer is at least as  
big as the query response structure.  
An invalid option keyword was found during option parsing.  
Explanation: An invalid option keyword was found in the dsmInit configuration  
file, the option string, dsm.sys, or dsm.opt.  
System Action: The system returns to the calling procedure.  
User Response: Correct the spelling of the option keywords. Verify that the  
dsmInit configuration file only has a subset of the dsm.sys options. Check the error  
log for more details about the error.  
ANS0261E  
ANS0262E  
ANS0263E  
The configuration file specified on dsmInit cannot be opened.  
Explanation: The configuration file specified on dsmInit cannot be opened.  
System Action: The system returns to the calling procedure.  
User Response: Verify the file name.  
The Include/Exclude definition file was not found.  
Explanation: The Include/Exclude definition file was not found.  
System Action: The system returns to the calling procedure.  
User Response: Verify the file name on the Inclexcl option.  
Either the dsm.sys file was not found, or the Inclexcl file specified in dsm.sys  
was not found.  
Explanation: Either the dsm.sys file was not found, or the Inclexcl file specified  
in dsm.sys was not found.  
System Action: The system returns to the calling procedure.  
User Response: The dsm.sys file must be in the directory referenced by the  
environment variable DSMI_DIR. Verify the file name on the Inclexcl option in the  
dsm.sys file.  
ANS0264E  
Only a UNIX root user can execute dsmChangePW or dsmDeleteFS.  
Explanation: Only a UNIX root user can execute dsmChangePW or dsmDeleteFS.  
System Action: The system returns to the calling procedure.  
User Response: Run this program as a root user.  
1102  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0265E  
ANS0266I  
You must issue dsmBindMC before dsmSendObj.  
Explanation: You must issue dsmBindMC before dsmSendObj.  
System Action: The system returns to the calling procedure.  
User Response: Modify your program.  
The dsmEndTxn vote is ABORT, so check the reason field.  
Explanation: After a dsmEndTxn call, the transaction is aborted by either the  
server or client with a DSM_VOTE_ABORT and the reason is returned.  
System Action: The system returns to the calling procedure.  
User Response: Check the reason field for the code which explains why the  
transaction has been aborted.  
ANS0268E  
ANS0269S  
Server problem: Destination not defined.  
Explanation: Server problem: Destination not defined.  
System Action: Processing stopped.  
User Response: Have your service representative check the error log.  
The structured file data type is unknown.  
Explanation: An unknown and unexpected error code occurred within the client  
program. The structured file data type is unknown. This is a programming failure  
and the client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator.  
ANS0270S  
The data buffer overflowed.  
Explanation: The data buffer overflowed. This is a programming failure and the  
client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator.  
ANS0271E  
ANS0272I  
No more files can be restored or retrieved since the destination directory is full.  
Explanation: No more files can be restored or retrieved since the destination  
directory is full.  
System Action: Processing stopped.  
User Response: Free up disk space, or restore or retrieve the file to another disk.  
The operation is finished.  
Explanation: The operation is finished.  
System Action: The system returns to the calling procedure.  
User Response: Proceed with next function call.  
Tivoli Storage Manager Messages  
1103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0273E  
ANS0274S  
The trusted agent execution/owner permissions are invalid.  
Explanation: The trusted agent execution/owner permissions are invalid.  
System Action: Processing stopped.  
User Response: Have your system administrator check the installation instructions  
for the client to ensure that the trusted agent permissions are set correctly.  
Process killed.  
Explanation: Processing stopped. This is a programming failure and the client  
program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator.  
ANS0275S  
ANS0276S  
ANS0277S  
ANS0278S  
Trusted agent would block the operation.  
Explanation: The trusted agent blocks the operation. This is a programming  
failure and the client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator.  
The area for the include/exclude pattern is too small.  
Explanation: The area for the include/exclude pattern is too small. This is a  
programming failure and the client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator.  
There is no closing bracket in the pattern.  
Explanation: There is no closing bracket in the pattern. This is a programming  
failure and the client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, contact your system  
administrator.  
The transaction will be aborted.  
Explanation: The server encountered an error and will abort the transaction.  
System Action: The transaction will be aborted. The reason code is passed on the  
dsmEndTxn call.  
User Response: Issue the dsmEndTxn with a vote of DSM_VOTE_COMMIT and  
examine the reason code.  
1104  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0279I  
A file was skipped during a restore operation because the file is off line and the  
application has chosen not to wait for a tape mount.  
Explanation: A file was skipped during a restore operation because the file is off  
line and the application has chosen not to wait for a tape mount.  
System Action: File skipped.  
User Response: Verify the application sets the mountWait value correctly on  
dsmBeginGetData.  
ANS0280E  
Unable to find Trusted Agent module.  
Explanation: TSM was unable to find the TSM Trusted Agent module in the  
specified directory. For V1R1 the name is dsmapita, for V1R2 the name is dsmtca,  
for V2R1 the name is dsmapitca.  
System Action: TSM ends.  
User Response: Make sure the Trusted Agent module is in the directory specified  
by DSMI_DIR.  
ANS0281E  
ANS0282E  
Access denied for dsmapitca.  
Explanation: An attempt to access a system function has been denied.  
System Action: Processing stopped.  
User Response: Contact your system administrator.  
Password file is not available.  
Explanation: The file containing the stored password for the specified  
server-name is unavailable.  
System Action: TSM ends.  
User Response: The root user must set and store a new password.  
ANS0283E  
ANS0284E  
High level qualifier of the object name should start with the directory delimiter.  
Explanation: The high level qualifier for the object name is invalid.  
System Action: The system returns to the calling procedure.  
User Response: High level qualifier of the object name should start with the  
directory delimiter.  
The number of objects on dsmBeginGetData exceeds DSM_MAX_GET_OBJ |  
DSM_MAX_PARTIAL_GET_OBJ.  
Explanation: The number of objects (numObjId) specified on the  
dsmBeginGetData call exceeds DSM_MAX_GET_OBJ |  
DSM_MAX_PARTIAL_GET_OBJ.  
System Action: The system returns to the calling procedure.  
User Response: Check the number of objects before calling dsmBeginGetData. If  
it is greater than DSM_MAX_GET_OBJ | DSM_MAX_PARTIAL_GET_OBJ, then  
issue multiple Get call sequences.  
Tivoli Storage Manager Messages  
1105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0285E  
ANS0286E  
The update action is invalid.  
Explanation: The dsmUpdateFS or dsmUpdateObj action is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Correct the action value. Valid values are defined in dsmapitd.h  
and documented in our Using the API book.  
The key file is missing.  
Explanation: The key file for Tivoli Data Protection application client for Oracle  
cannot be found.  
System Action: The system returns to the calling procedure.  
User Response: Ensure that you have ordered the Tivoli Data Protection  
application client which contains TDP for Oracle, and install the key file.  
ANS0287E  
ANS0296E  
ANS0301E  
The key file content is invalid.  
Explanation: The key file content for Tivoli Data Protection application client for  
Oracle is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Ensure that you have ordered the Tivoli Data Protection  
application client which contains the TDP for Oracle, and install the key file.  
The PC/3270 EHLLAPI DLL pcshll.dll cannot be found in the user’s path.  
Explanation: The PC/3270 EHLLAPI DLL pcshll.dll cannot be found in the user's  
path.  
System Action: Communications link is not established.  
User Response: Contact your system administrator. Make sure that the PS/3270  
EHLLAPI DLLs are in a directory that is included in the user's path.  
The TSM DLL dsm3270.dll cannot be found in the user’s path.  
Explanation: The TSM DLL dsm3270.dll cannot be found in the user's path.  
System Action: Communications link is not established.  
User Response: Make sure that the TSM DLL dsm3270.dll is in a directory that is  
included in the user's path.  
ANS0302I  
ANS0315E  
Successfully done.  
Explanation: The operation successfully completed.  
System Action: None.  
User Response: None.  
Unable to open message text file.  
Explanation: The system is unable to open the message txt file (dscameng.txt or  
dsmclientV3.cat for AIX). On the AS/400 platform this file is  
QANSAPI/QAANSAMENG(TXT).  
1106  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The system returns to the calling procedure.  
User Response: Verify that the dscameng.txt file is in the directory pointed to by  
DSMI_DIR. For AIX, verify that the dsmclientV3.cat file has a symbolic link to  
/usr/lib/nls/msg/<locale>/dsmclientV3.cat .  
ANS0316E  
ANS0317E  
Unable to use message text file.  
Explanation: The system is unable to use the message text file (dscameng.txt or  
dsmclientV3.cat for AIX) because of an invalid header. On the AS/400 platform this  
file is QANSAPI/QAANSAMENG(TXT).  
System Action: The system returns to the calling procedure.  
User Response: Install the message text file again.  
Unable to use message text file.  
Explanation: The system is unable to use the message txt file (dscameng.txt or  
dsmclientV3.cat for AIX) because of an invalid control record. On the AS/400  
platform this file is QANSAPI/QAANSAMENG(TXT).  
System Action: The system returns to the calling procedure.  
User Response: Install the message text file again.  
ANS0318E  
ANS0319E  
ANS0320E  
ANS0321E  
ANS0322E  
Invalid value for DATEFORMAT specified.  
Explanation: An invalid value is specified for DATEFORMAT.  
System Action: The system returns to the calling procedure.  
User Response: Specify a valid value.  
Invalid value for TIMEFORMAT specified.  
Explanation: An invalid value is specified for TIMEFORMAT.  
System Action: The system returns to the calling procedure.  
User Response: Specify a valid value.  
Invalid value for NUMBERFORMAT specified.  
Explanation: An invalid value is specified for NUMBERFORMAT.  
System Action: The system returns to the calling procedure.  
User Response: Specify a valid value.  
msg parameter for dsmRCMsg is a NULL pointer.  
Explanation: The message parameter for dsmRCMsg is a NULL pointer.  
System Action: The system returns to the calling procedure.  
User Response: Allocate enough space for the message parameter.  
no text available for this return code.  
Explanation: The dsmRC parameter for dsmRCMsg is an unsupported return  
code.  
Tivoli Storage Manager Messages  
1107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The system returns to the calling procedure.  
User Response: Specify a valid value.  
ANS0323E  
ANS0324E  
ANS0325E  
partialObjOffset value for partial object retrieve is invalid.  
Explanation: The partialObjOffset value for partial object retrieve is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Specify a valid value.  
partialObjLength value for partial object retrieve is invalid.  
Explanation: partialObjLength value for partial object retrieve is invalid.  
System Action: The system returns to the calling procedure.  
User Response: Specify a valid value.  
Partial Object Retrieve is not supported on this server.  
Explanation: The TSM server specified by the user does not support partial object  
retrieve.  
System Action: The system returns to the calling procedure.  
User Response: Specify a TSM server which supports the partial object retrieve  
function.  
ANS0326E  
Node has exceeded max tape mounts allowed.  
Explanation: All the tape mount points for this node are in use.  
System Action: The system returns to the calling procedure.  
User Response: Increase the number of allowed tape mounts for this node on the  
server.  
ANS0327E  
ANS0328E  
A duplicate object was found, operation cannot complete.  
Explanation: A duplicate object was found, operation cannot complete.  
System Action: The requested operation failed.  
User Response: Try the operation with a different file specification.  
The specified objects failed the merge test.  
Explanation: The specified objects failed the merge test, operation cannot  
complete.  
System Action: The requested operation failed.  
User Response: See documentation for the merge test parameters.  
ANS0330E  
The dsmSetAccess access Type is invalid.  
Explanation: The dsmSetAccess accessType is invalid.  
System Action: The system returns to the calling procedure.  
User Response: The accessType must be one of the following:  
1108  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
atBackup  
atArchive  
ANS0331E  
ANS0332E  
ANS0400E  
ANS0401E  
ANS0402E  
ANS0403E  
No files have been previously backed up for this filename/filespace.  
Explanation: You tried to set access to files when no files for the specified  
filename, drive or file system were previously backed up.  
System Action: Processing stopped.  
User Response: Ensure that the correct drive or file system was specified and that  
files are backed up for you to set access.  
No files have been previously archived for this filename/filespace.  
Explanation: You tried to set access to files when no files for the specified  
filename, drive or file system were previously archived.  
System Action: Processing stopped.  
User Response: Ensure that the correct drive or file system was specified and that  
files are archived for you to set access.  
License file could not be opened.  
Explanation: The license file was not found, or could not be opened because of  
permissions or the file is corrupted.  
System Action: The system returns to the calling procedure.  
User Response: Check permissions on file. See if the license file is in the correct  
place.  
Read failure on the license file.  
Explanation: The license file was not found, or could not be opened because of  
permissions, or the file is corrupted.  
System Action: The system returns to the calling procedure.  
User Response: Check permissions on file. See if the license file is in the correct  
place.  
Write failure on the license file.  
Explanation: The license file was not found, or could not be opened because of  
permissions or the file is corrupted.  
System Action: The system returns to the calling procedure.  
User Response: Check permissions on file. See if license file is in the correct  
place.  
Data in the license file is not in a valid format.  
Explanation: The license file is not valid.  
System Action: The system returns to the calling procedure.  
User Response: User needs to obtain a new license.  
Tivoli Storage Manager Messages  
1109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0404E  
ANS0405E  
The checksum in the license file does not match the licenseregistration string.  
Explanation: The registration string is not valid.  
System Action: The system returns to the calling procedure.  
User Response: User needs to obtain a new license.  
This is an expired try and buy license.  
Explanation: The registration string is not valid.  
System Action: The system returns to the calling procedure.  
User Response: User needs to obtain a new license.  
1110  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Client Common Messages  
(1000–1999)  
ANS1000E  
Attempting to use a communications method that is not supported  
Explanation: You specified a communication method that is not supported.  
System Action: Processing stopped.  
User Response: Specify a valid communication interface for the TSM client and  
your operating system.  
ANS1001E  
Volume being backed up was not a system volume. Skipped.  
Explanation: User specified to back up system volume only. This volume was not  
backed up since this volume is not a system volume.  
System Action: Volume was not backed up.  
User Response: Use All option or use image backup command to backup this  
volume.  
ANS1002I  
MOS image is being created. It may take a while.  
Explanation: Mini Operating System image is beging created. It may take a while  
to create it.  
System Action: TSM is gathering necessary information.  
User Response: None.  
ANS1003W  
You are trying to compress the data for this backup. If the data is compressed,  
file by file restore will not be performed. Do you wish to continue?  
Explanation: User is trying to compress the data for this backup. If the data is  
compressed, file by file restore will not be performed during restore. Only image  
restore will be performed.  
System Action: If user’s response is yes, the data will be compressed, otherwise  
operation will be aborted.  
User Response: Enter either Yes or No.  
Tivoli Storage Manager Messages  
1111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS1009E  
ANS1010E  
ANS1011E  
Session rejected: Specified gateway name gateway cannot be connected to. See  
your system administrator.  
Explanation: Cannot connect to specified gateway.  
System Action: Communications link is not established.  
User Response: See your system administrator on status of the LAN.  
Session rejected: NETBIOS session not established.  
Explanation: The client cannot access the NETBIOS server.  
System Action: Session is not established.  
User Response: Ensure that NETBIOS is loaded and that the NETBIOS server is  
active. See your system administrator on status of the LAN.  
Session rejected: The OS/2 LAN file ACSNETB.DLL is not available or is  
invalid.  
Explanation: The OS/2 LAN file ACSNETB.DLL is not available to establish a  
communications link, or the file is incorrect.  
System Action: Communications link is not established.  
User Response: See your system administrator.  
ANS1012E  
ANS1013E  
ANS1014E  
ANS1015E  
Session rejected: Communication session was unexpectedly ended  
Explanation: The communication session ended unexpectedly.  
System Action: Communications link is not established.  
User Response: See your system administrator.  
Session rejected: Error accessing the LAN. See your system administrator.  
Explanation: Error accessing the LAN.  
System Action: Communications link is not established.  
User Response: See your system administrator.  
Session rejected: LAN failure while in session with server  
Explanation: LAN communications failure detected while in session with server.  
System Action: Communications link is not established.  
User Response: See your system administrator.  
Session rejected: LAN resources are exhausted for your system. See your  
system administrator.  
Explanation: LAN resources are exhausted for your system and the session was  
rejected.  
System Action: Communications link is not established.  
User Response: See your system administrator.  
1112  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1016E  
ANS1017E  
Session rejected: Unexpected LAN error. Unknown cause. See your system  
administrator.  
Explanation: An unexpected LAN error occurred.  
System Action: Communications link is not established.  
User Response: These errors may be caused by a failure on the LAN external to  
TSM. See your system administrator to ensure that your LAN is operating properly.  
Session rejected: TCP/IP connection failure  
Explanation: An attempt to connect to the server using TCP/IP communications  
failed. This error can occur if the LAN connection went down or if your system  
administrator canceled a backup operation.  
System Action: Session rejected. Processing stopped.  
User Response: Retry the operation, or wait until the server comes back up and  
retry the operation. If the problem continues, see your system administrator for  
further help.  
ANS1018E  
Session rejected: NETBIOS name error  
Explanation: An attempt to add the client NETBIOS name failed, or an attempt to  
call the server NETBIOS name failed.  
System Action: Processing stopped.  
User Response: Verify that your NETBIOSNAME option value is unique. Verify  
that your NETBIOSSERVERNAME option value is correct. Verify that the server  
has NETBIOS support running. If the problem continues, see your system  
administrator for further help.  
ANS1019E  
Session rejected: NETBIOS timeout  
Explanation: A timeout occurred when transmitting data with the NETBIOS  
protocol.  
System Action: Processing stopped.  
User Response: Make sure the server is operational. You may need to increase the  
NETBIOSTIMEOUT value or use a value of 0 for no timeout. If the problem  
continues, see your system administrator for further help.  
ANS1020E  
Session rejected: NETBIOS not installed  
Explanation: The product for NETBIOS is not installed.  
System Action: Processing stopped.  
User Response: Verify that the product for NETBIOS, such as the LAN Support  
Program, is installed. If the problem continues, see your system administrator for  
further help.  
Tivoli Storage Manager Messages  
1113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1021E  
NETBIOS configuration error: Reboot the machine.  
Explanation: A DOS or Windows NETBIOS error has occurred which requires  
that the adapter be reset. This may be caused by a software installation or adapter  
configuration error.  
System Action: Processing stopped.  
User Response: Reboot the machine. If the error recurs, check the TSM error log  
to find the NETBIOS return code. See your system administrator for help with your  
NETBIOS installation/configuration problem.  
ANS1022E  
ANS1023E  
Cannot start application specified on the BOOKS option.  
Explanation: Could not start the application specified on the BOOKS option.  
System Action: Processing continues.  
User Response: Correct the option and restart the program.  
Session rejected: Node type mismatch  
Explanation: Your node name is associated with a different type of operating  
system (such as OS/2 or AIX) and cannot be used on this system.  
System Action: TSM canceled the current operation.  
User Response: If you need a new node name, see your system administrator to  
assign a new one to you. Generally, you have a unique node name for each machine  
and operating system pair that requires access to the server.  
ANS1024E  
ANS1025E  
Session rejected: Unable to locate required file WSOCK32.DLL  
Explanation: The 32-Bit Windows Sockets DLL WSOCK32.DLL could not be  
located  
System Action: Communications link is not established. Session rejected.  
User Response: See your system administrator.  
Session rejected: Authentication failure  
Explanation: Authentication failure. You entered an incorrect password.  
System Action: TSM canceled the current operation.  
User Response: Enter your correct password. If you cannot remember the correct  
password, see your system administrator to have a new one assigned for your node  
name.  
ANS1026E  
Session rejected: Communications protocol error  
Explanation: Communications protocol error. An unexpected communications  
message was received by the client.  
System Action: TSM canceled the current operation.  
User Response: Verify that your communication path is functioning properly. If  
the problem continues, have your service representative check for a possible  
program error.  
1114  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1027E  
Session failure: Server not available  
Explanation: The server cannot be accessed at this time.  
System Action: TSM canceled the current operation.  
User Response: Retry the operation later. If the server continues to be unavailable,  
see your system administrator to see if the server is operating properly. If the server  
is operating properly, you might have your TSM client incorrectly installed or some  
parameter in your communication path might have been modified.  
ANS1028S  
Internal program error. Please see your service representative.  
Explanation: An unexpected program failure occurred.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your system  
administrator or your service representative.  
ANS1029E  
ANS1030E  
Communications have been dropped.  
Explanation: Communications with the server dropped.  
System Action: Processing stopped.  
User Response: Restart the TSM client and retry the operation.  
System ran out of memory. Process ended.  
Explanation: TSM cannot allocate storage for the specified operation.  
System Action: TSM cannot complete the requested operation.  
User Response: Stop TSM, restart TSM, and retry the operation. If unsuccessful,  
close all unneeded applications and retry the operation. For UNIX systems that  
support resource limits, you can check if the memory resource limit is too low by  
entering the following command: ulimit -a Based on the resulting data, you can  
ask the UNIX system root user to increase resource limits so that it will override the  
current default. The UNIX system root user has the authority to increase resource  
limits.  
ANS1031E  
Establishment of a TCP/IP connection timed out before connection was made  
Explanation: The attempt to establish a TCP/IP connection timed out before the  
connection was made.  
System Action: Processing stopped.  
User Response: Check for a networking problem. If the problem continues, see  
your system administrator. API applications should close the session with  
dsmTerminate.  
ANS1032E  
An attempt to establish a TCP/IP connection was rejected by the host  
Explanation: An attempt to establish a TCP/IP connection was rejected by the  
server.  
System Action: Processing stopped.  
Tivoli Storage Manager Messages  
1115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The server was not fully initialized, is not currently running, was  
not enabled for TCP/IP communications, or an incorrect TCP/IP port number was  
specified. If the problem continues, see your system administrator.  
ANS1033E  
ANS1034E  
An invalid TCP/IP host name was specified  
Explanation: An invalid TCP/IP host name or address was specified.  
System Action: Processing stopped.  
User Response: Check your options file for the correct TCPSERVERADDRESS  
statement. See your administrator for the correct name of the server.  
The specified TCP/IP host name is unreachable  
Explanation: The TCP/IP host name specified in the TCPSERVERADDRESS  
statement cannot be reached.  
System Action: Processing stopped.  
User Response: Check your options file for the correct TCPSERVERADDRESS  
statement. See your administrator for the correct name of the server.  
ANS1035S  
Options file ’file-name’ not found  
Explanation: The options file specified by file-name cannot be found.  
System Action: The TSM client ends.  
User Response: See if you have the environment variable DSM_CONFIG (or  
DSMI_CONFIG for the API) set, which explicitly identifies the TSM options file. (  
You can do this by entering the SET command at your system.) If this environment  
variable is set, ensure the file indicated by the variable exists. If it is not set, then  
TSM looks for the file dsm.opt in the current directory. If neither of these cases is  
met, you receive this error message.  
ANS1036S  
Invalid option ’option’ found in options file ’file-name’ at line number : number  
Invalid entry : ’entry’  
Explanation: The specified option in the TSM options file (file-name) is in error.  
System Action: Processing stopped.  
User Response: Correct the options file entry.  
ANS1037S  
ANS1038S  
Invalid keyword specified  
Explanation: TSM found an incorrect keyword in the options file.  
System Action: Processing stopped.  
User Response: Correct the options file with valid entries.  
Invalid option specified  
Explanation: An incorrect option was specified to TSM.  
System Action: Processing stopped.  
User Response: Correct the options used for running TSM.  
1116  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1039S  
Include/Exclude pattern too complex  
Explanation: The include or exclude pattern issued is too complex to be  
accurately interpreted by TSM.  
System Action: Processing stopped.  
User Response: Recode the include or exclude pattern as shown in one of the  
examples in the appropriate Using the Backup-Archive Client book for the particular  
operating system.  
ANS1040S  
Include/Exclude pattern is missing a closing bracket  
Explanation: The include or exclude pattern is incorrectly constructed. The closing  
bracket is missing.  
System Action: Processing stopped.  
User Response: Correct the syntax for the pattern.  
ANS1041S  
ANS1042S  
Include/Exclude pattern must start with a directory delimiter  
Explanation: The include or exclude pattern must start with a directory delimiter.  
System Action: Processing stopped.  
User Response: Correct the syntax for the pattern.  
Include/Exclude pattern has a ’...’ without beginning/ending directory delimiter  
Explanation: The include/exclude pattern has a ’...’ without a beginning or ending  
directory delimiter.  
System Action: Processing stopped.  
User Response: Correct the syntax for the pattern.  
ANS1043S  
ANS1044S  
Quotes are not matched  
Explanation: The quotes specified in the pattern are not the same and do not  
make a set.  
System Action: Processing stopped.  
User Response: Correct the pattern by using matching quotes in the syntax.  
Unresolved environment name ’environment-name’.This filespace is being  
ignored. Processing Continues.  
Explanation: The specified environment-name in the options file is invalid.  
System Action: TSM attempts to continue the current operation.  
User Response: Check the environment variable in the options file and use a valid  
environment variable. Retry the operation.  
ANS1045S  
Environment variable syntax error.  
Explanation: Incorrect syntax is specified in the options file. Make sure that the  
variable is enclosed in curly braces.  
System Action: TSM attempts to continue the current operation.  
Tivoli Storage Manager Messages  
1117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check the syntax of environment variable in the options file.  
Correct it and retry the operation.  
ANS1046S  
Environment string for variable ’environment-name’ too long. Anything beyond  
1024 characters is being ignored  
Explanation: Environment variable expanded to a string which is too long. Make  
sure that the string is no more than 1023 characters long.  
System Action: TSM attempts to continue the current operation.  
User Response: Check the length of environment string and break it up into  
smaller strings using multiple environment variables.  
ANS1047E  
Establishment of an IPX/SPX connection timed out before the connection was  
made.  
Explanation: The attempt to establish an IPX/SPX connection timed out before  
the connection was made.  
System Action: Processing stopped.  
User Response: Check for an IPX/SPX networking problem. Ensure that the  
server is fully initialized, is currently running, and is enabled for IPX/SPX  
communications. Verify that the server address is correct in the  
IPXSERVERADDRESS statement in the options file. If the problem continues, see  
your system administrator.  
ANS1048E  
An attempt to establish an IPX/SPX connection was refused.  
Explanation: An attempt to establish an IPX/SPX connection was rejected by the  
server.  
System Action: Processing stopped.  
User Response: The server was not fully initialized, is not currently running, was  
not enabled for IPX/SPX communications, or an incorrect IPX/SPX port number  
was specified. Verify that th IPX/SPX port number is correct in the IPXSOCKET  
statement in the options file. If the problem continues, see your system  
administrator.  
ANS1049E  
ANS1050S  
The specified IPX/SPX server address is unreachable.  
Explanation: The IPX/SPX host name specified in the IPXSERVERADDRESS  
statement cannot be reached.  
System Action: Processing stopped.  
User Response: Check your options file for the correct IPXSERVERADDRESS  
statement. See your administrator for the correct name of the server.  
DBCS Characters are not allowed in an Include/Exclude range  
Explanation: Only single-byte characters are allowed in an include/exclude list;  
you cannot use a double-byte character set (DBCS).  
System Action: Processing stopped.  
1118  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Remove the double-byte characters from the include/exclude list  
and retry the operation.  
ANS1051E  
ANS1052E  
Invalid password  
Explanation: You entered an invalid password.  
System Action: TSM cannot connect to the server without the correct password.  
User Response: Enter the password, or ask your system administrator for the  
correct password.  
A beginning delimiter (begin-delimiter) was not matched by the corresponding  
ending delimiter (end-delimiter)  
Explanation: The beginning delimiter must be paired with the required ending  
delimiter to make a valid argument.  
System Action: The process is stopped.  
User Response: Correct the input and re-submit.  
ANS1058E  
Restore destination is unreachable.  
Explanation: Trying to restore to destination that cannot be reached. Either the  
drive letter is not valid, or you are specifying a local share name that cannot be  
resolved.  
System Action: Processing stopped.  
User Response: Retry the command and specify a different destination.  
ANS1063E  
ANS1064E  
ANS1065E  
ANS1066E  
Invalid path specification  
Explanation: The path specified is not a valid file-system or logical volume name.  
System Action: The requested logical volume operation is not performed.  
User Response: Retry the operation, using a valid path.  
Internal error  
Explanation: An error occurred in the image utility internals.  
System Action: The requested logical volume operation is not performed.  
User Response: Contact your TSM administrator.  
Library version of the image utility does not match that of the TSM API  
Explanation: The current system has a mix of installed components.  
System Action: The requested logical volume operation is not performed.  
User Response: Re-install all TSM components  
Restore successful. File system mount failed.  
Explanation: The file system was successfully restored, but the attempt to  
re-mount it failed.  
System Action: The file system is left unmounted.  
Tivoli Storage Manager Messages  
1119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the mount command to mount the file system. On AIX, run  
fsck if requested by the operating system.  
ANS1067E  
ANS1068E  
Error in system call, check log file for more information  
Explanation: An error occurred during a system call, check the error log for more  
information.  
System Action: The requested logical volume operation is not performed.  
User Response: Check error log.  
Device is not local  
Explanation: The selected path is not a local device and therefore is not a valid  
object for image operations  
System Action: The requested logical volume operation is not performed.  
User Response: Choose another object.  
ANS1069E  
ANS1070E  
ANS1131E  
An error occurred while reading data from the device  
Explanation: An error occurred while reading data from the device.  
System Action: The requested logical volume operation is not performed.  
User Response: Re-try the operation, check error log for more information.  
Write error  
Explanation: An error occurred while writing data to the device.  
System Action: The requested logical volume operation is not performed.  
User Response: Re-try the operation, check error log for more information.  
Unable to continue operation. Duplicate labels exist.  
Explanation: The selected drive has a duplicate volume label. Because TSM uses  
the volume label to keep track of backup/archive information, it cannot back up or  
archive files from a drive with a duplicate volume label.  
System Action: TSM cannot select the drive.  
User Response: If the volume needs to be available to the system, exit TSM, and  
assign a volume label to the drive. Restart TSM and retry the operation.  
ANS1150E  
Unable to restore current user profile because you are running as a local  
system account.  
Explanation: The local system account does not have a profile. Therefore you  
cannot restore its profile.  
System Action: Processing stops.  
User Response: Log on to the user whose profile you want to restore.  
1120  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1151E  
ANS1152E  
ANS1153E  
ANS1154E  
ANS1155E  
Drive drive-name1: is not a cluster disk. Not valid for backup/archive when  
CLUSTERNODE option is YES.  
Explanation: The drive-name1 is not a cluster disk. Backup/archive is not allowed  
when the CLUSTERNODE option is set to YES.  
System Action: Processing stops.  
User Response: Set CLUSTERNODE option to NO, then backup/archive the  
drive. Otherwise, you cannot backup/archive the drive.  
Drive filespace is not a cluster disk. Not valid for backup/archive when  
CLUSTERNODE option is YES.  
Explanation: The filespace is not a cluster disk. Backup/archive is not allowed  
when the CLUSTERNODE option is set to YES.  
System Action: Processing stops.  
User Response: Set CLUSTERNODE option to NO, then backup/archive the  
drive. Otherwise, you cannot backup/archive the drive.  
Drive drive-name1: is a cluster disk. Not valid for backup/archive when  
CLUSTERNODE option is NO.  
Explanation: The drive-name1 is a cluster disk. Backup/archive is not allowed  
when the CLUSTERNODE option is set to NO.  
System Action: Processing stops.  
User Response: Set CLUSTERNODE option to YES, then backup/archive the  
drive. Otherwise, you cannot backup/archive the drive.  
Drive filespace is a cluster disk. Not valid for backup/archive when  
CLUSTERNODE option is NO.  
Explanation: The filespace is a cluster disk. Backup/archive is not allowed when  
the CLUSTERNODE option is set to NO.  
System Action: Processing stops.  
User Response: Set CLUSTERNODE option to YES, then backup/archive the  
drive. Otherwise, you cannot backup/archive the drive.  
CLUSTERNODE option is set to YES but cluster is not enabled. Either the  
machine does not have cluster server installed, or the cluster server is not  
running.  
Explanation: If CLUSTERNODE option is set to YES, TSM must be running on  
a Windows NT Server Enterprise Edition machine with the cluster server installed  
and running.  
System Action: Processing stops.  
User Response: Ensure TSM is running in a cluster environment and that the  
cluster server has been started.  
Tivoli Storage Manager Messages  
1121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1156E  
NODENAME cannot be the local machine name when CLUSTERNODE is set  
to YES  
Explanation: When TSM is running as a cluster node, the nodename cannot be the  
local machine name.  
System Action: Processing stops.  
User Response: Change the nodename either to the cluster name or to any other  
name, and restart TSM.  
ANS1157I  
ANS1158I  
ANS1162E  
ANS1163E  
ANS1164E  
ANS1165E  
Backup/Restore of the registry is not allowed when running as a cluster node.  
Explanation: When running as a cluster node, registry cannot be backed up or  
restored.  
System Action: Processing continues.  
User Response: None.  
Backup/Restore of the event logs is not allowed when running as a cluster node.  
Explanation: When running as a cluster node, event logs cannot be backed up or  
restored.  
System Action: Processing continues.  
User Response: None.  
Filesystem could not be mounted  
Explanation: The system call to mount the file system failed.  
System Action: The file system remains unmounted.  
User Response: Use the mount command to mount the file system. On AIX, run  
fsck if requested by the operating system.  
Filesystem could not be unmounted.  
Explanation: The system call to unmount the file system failed.  
System Action: The logical volume operation is not performed.  
User Response: Make sure the device or file system is not being accessed, then  
retry the operation.  
Filesystem is not mounted  
Explanation: The named file system is not currently mounted. It must be mounted  
for TSM to perform an image backup.  
System Action: The logical volume operation is not performed.  
User Response: Mount the file system.  
Destination is smaller than source  
Explanation: The space allocation for the selected destination is smaller than the  
source.  
System Action: The restore operation is not performed.  
1122  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Choose a different, bigger destination or increase the size of the  
destination file space.  
ANS1166E  
ANS1202E  
ANS1203E  
ANS1204E  
ANS1205E  
ANS1206E  
Source and destination are not the same file system type.  
Explanation: The source and destination file system types do not match.  
System Action: The requested logical volume operation is not performed.  
User Response: Choose a destination that has the same file system type as the  
source.  
TOC backup for the image failed. Check log files.  
Explanation: An error occurred during backup of the table of contents. Chek the  
error log for more information.  
System Action: The requested logical volume operation is not performed.  
User Response: Check error log.  
Deactivating the TOC object failed.  
Explanation: An error occurred while deactivating the table of contents object.  
System Action: Image backup was successful. But deactivating the TOC object  
from the previous backup failed.  
User Response: Check error log.  
Image restore failed. Check the error log.  
Explanation: An error occurred while restoring the image. Check log file for more  
information.  
System Action: Restore stops. The file system is not mounted back.  
User Response: Check error log.  
Image backup failed. Check the error log.  
Explanation: An error occurred while backing up the image. Check log file for  
more information.  
System Action: Backup stopped. The file system is not mounted back.  
User Response: Check error log.  
TOC backup of a raw device is not supported. But the raw device is backed  
up.  
Explanation: TOC backup of a raw device is not supported. But the raw device is  
backed up.  
System Action: Raw device is backed up with no TOC object.  
User Response: NONE.  
Tivoli Storage Manager Messages  
1123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1207E  
ANS1229E  
No TOC has been previously backed up for this file system.  
Explanation: The user is trying to query the TOC of a file system. TOC backup  
for that file system has not been previously done.  
System Action: Query stopped.  
User Response: Backup the file system again with -TOC option.  
MODE=INCREMENTAL invalid on file-space. Image backup not processed.  
Explanation: The MODE=INCREMENTAL option is not valid on file-space  
because the filespace has been the subject of a progressive incremental backup since  
the last full image backup was performed.  
System Action: File system skipped.  
User Response: If an image backup of the named file-system is desired, retry  
without the MODE=INCREMENTAL option.  
ANS1270E  
ANS1271E  
ANS1274E  
ANS1275E  
Error Loading ACPOCPIC.DLL - not in Search Path  
Explanation: TSM cannot find the PWSCS CPIC support file (ACPOCPIC.DLL)  
in the current search path. This message only applies when using PWSCS  
communications.  
System Action: Connection to server fails.  
User Response: Shut down Windows and place the directory where this file  
resides in the DOS path statement.  
Error Loading WINSOCK.DLL - not in Search Path  
Explanation: TSM cannot find the Windows Socket support file  
(WINSOCK.DLL) in the current search path. This message only applies when using  
TCP/IP communications.  
System Action: Connection to server fails.  
User Response: Shut down Windows and place the directory where this file  
resides in the DOS path statement.  
Error Loading WINSOCK.DLL  
Explanation: Error loading the Windows socket support file into memory. This  
error only applies when using TCP/IP communications.  
System Action: Connection to server fails.  
User Response: Because this error is caused by insufficient memory, shut down  
running applications and retry. If the problem persists, see your system  
administrator.  
Error Loading Function(s) from WINSOCK.DLL  
Explanation: Error loading one or more functions from the Windows socket  
support file.  
System Action: Connection to server fails.  
1124  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Since this might possibly be caused by insufficient memory, shut  
down running applications and retry. If the problem persists, see your system  
administrator.  
ANS1276E  
ANS1277E  
ANS1290E  
ANS1291E  
Error Loading ACPOCPIC.DLL  
Explanation: Error loading the PWSCS CPIC support file into memory. This error  
only applies when using PWSCS communications.  
System Action: Connection to server fails.  
User Response: Since this might possibly be caused by insufficient memory, shut  
down running applications and retry. If the problem persists, see your system  
administrator.  
Error Loading Function(s) from ACPOCPIC.DLL  
Explanation: Error loading one or more functions from the PWSCS CPIC support  
file. This error only applies when using PWSCS communications.  
System Action: Connection to server fails.  
User Response: Since this might possibly be caused by insufficient memory, shut  
down running applications and retry. If the problem persists, see your system  
administrator.  
NSDW.DLL not found in search path.  
Explanation: TSM cannot find the NS/DOS communications support file  
(NSDW.DLL) in the current search path. This message only applies when using  
SNALU6.2 communications.  
System Action: Connection to server fails.  
User Response: Shut down Windows and place the directory where this file  
resides in the DOS path statement.  
Error loading NSDW.DLL.  
Explanation: An error occurs while loading the NS/DOS communications support  
file (NSDW.DLL) into memory. This error only applies when using SNALU6.2  
communications.  
System Action: Connection to server fails.  
User Response: Because this is probably caused by insufficient memory, shut  
down running applications and retry. If the problem persists, contact your support  
personnel.  
ANS1292E  
Error loading one or more functions from NDSW.DLL.  
Explanation: An error occurs while loading one or more functions from the  
NS/DOS communications support file (NSDW.DLL). This error only applies when  
using SNALU6.2 communications.  
System Action: Connection to server fails.  
Tivoli Storage Manager Messages  
1125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Because this is probably caused by insufficient memory, shut  
down running applications and retry. If the problem persists, contact your support  
personnel.  
ANS1293E  
EHNAPPC.DLL not found in search path.  
Explanation: TSM cannot find the Client Access/400 or PC Support/400  
communications support file (EHNAPPC.DLL) in the current search path. This  
message only applies when using 400 APPC communications.  
System Action: Connection to server fails.  
User Response: Shut down Windows and place the directory where this file  
resides in the DOS path statement.  
ANS1294E  
Error loading EHNAPPC.DLL.  
Explanation: An error occurs while loading the Client Access/400 or PC  
Support/400 communications support file (EHNAPPC.DLL) into memory. This error  
only applies when using 400 APPC communications.  
System Action: Connection to server fails.  
User Response: Because this is probably caused by insufficient memory, shut  
down running applications and retry. If the problem persists, contact your support  
personnel.  
ANS1295E  
Error loading one or more functions from EHNAPPC.DLL.  
Explanation: An error occurs while loading one or more functions from the Client  
Access/400 or PC Support/400 communications support file (EHNAPPC.DLL). This  
error only applies when using 400 APPC communications.  
System Action: Connection to server fails.  
User Response: Because this is probably caused by insufficient memory, shut  
down running applications and retry. If the problem persists, contact your support  
personnel.  
ANS1296E  
Error Loading WCPIC32.DLL - not in Search Path  
Explanation: TSM cannot find the Windows SNA client CPIC support file  
(WCPIC32.DLL) in the current search path. This message only applies when using  
SNALU6.2 communications.  
System Action: Connection to server fails.  
User Response: Shut down Windows and place the directory where this file  
resides in the DOS path statement.  
ANS1297E  
Error Loading WCPIC32.DLL  
Explanation: Error loading the Windows SNA client CPIC support file into  
memory. This error only applies when using SNALU6.2 communications.  
System Action: Connection to server fails.  
1126  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Since this might possibly be caused by insufficient memory, shut  
down running applications and retry. If the problem persists, contact your system  
administrator.  
ANS1298E  
Error Loading Function(s) from WCPIC32.DLL  
Explanation: Error loading one or more functions from the Windows SNA client  
CPIC support file. This error only applies when using SNALU6.2 communications.  
System Action: Connection to server fails.  
User Response: Since this might possibly be caused by insufficient memory, shut  
down running applications and retry. If the problem persists, contact your system  
administrator.  
ANS1299E  
Session rejected: SNALU6.2 connection failure. Unable to register as a  
Windows CPIC application.  
Explanation: An attempt to register the application with the Windows SNA client  
CPIC implementation failed. This error may occur when the the network subsystem  
is not ready for network communications or when the version of the Windows SNA  
client CPIC implementation is not supported. This error only applies when using  
SNALU6.2 communications.  
System Action: Connection to server fails.  
User Response: Verify that the network subsystem is ready for network  
communications and that the version of the Windows SNA client CPIC  
implementation is supported and retry. If the problem persists, contact your system  
administrator.  
ANS1300E  
ANS1341E  
ANS1342E  
Unable to reconstruct ’’: necessary component was not restored.  
Explanation: A subfile component was not received by the client during the  
restore process.  
System Action: Processing stopped.  
User Response: Please check error log for more information.  
Delta file ’delta-file-name’ already exists on client cache.  
Explanation: The number defining the correspondence between drive letter or file  
(domain name) and volume label is not known to the server.  
System Action: Processing stopped.  
User Response: Report the program error to your service representative.  
Client cache is locked; unable to continue with operation.  
Explanation: The client cache is currently locked by another process.  
System Action: Processing stopped.  
User Response: Report the program error to your service representative.  
Tivoli Storage Manager Messages  
1127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1343E  
ANS1344E  
Wrong Key entered; unable to restore the file.  
Explanation: Key entered does not match the key used for the backed up file.  
System Action: Processing stopped.  
User Response: Recollect the key used for backup.  
Job is running in the background. Cannot prompt for the Key.  
Explanation: When jobs are run in the background, the client cannot prompt for  
the key.  
System Action: Processing stopped.  
User Response: Run the Job in the foreground.  
ANS1345E  
ANS1351E  
The client cache verification record cannot be located.  
Explanation: The client cache verification record cannot be located. This record is  
located based on information made available during product installation. The  
product must be re-installed in order to update this information correctly.  
System Action: Processing stopped.  
User Response: Report the program error to your service representative.  
Session rejected: All server sessions are currently in use  
Explanation: TSM has all available sessions in use and cannot accept a new one  
at this time.  
System Action: TSM canceled the current operation.  
User Response: Retry the operation. If the problem continues, see your system  
administrator to increase the number of concurrently active sessions to the server.  
ANS1352E  
ANS1353E  
Session rejected: Password has expired  
Explanation: Your TSM password has expired.  
System Action: TSM canceled the current operation. You are not allowed to  
connect to the server until the password is updated.  
User Response: Update your password.  
Session rejected: Unknown or incorrect ID entered  
Explanation: The node name you entered is not known by the server, or you are  
attempting to access a file migrated to a different node.  
System Action: TSM canceled the current operation. You are not allowed to  
connect to the server until your node name is registered with the server. If  
attempting to access a migrated file, your nodename must be the same node which  
migrated the file.  
User Response: Ensure that you entered your TSM node name correctly. If yes,  
see your system administrator. Verify that the server is using closed registration and  
that your node name is registered with the server.  
1128  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1354E  
Session rejected: Duplicate ID entered  
Explanation: Another process using this node name is active with the server.  
System Action: TSM cannot connect to the server. TSM canceled the current  
operation.  
User Response: If you are running a UNIX-based system, ensure that another  
process is not active with TSM under the same name. Also, ensure that your node  
name is unique to the server so that it cannot be used by another person. See your  
system administrator to identify the owner of that node name.  
ANS1355E  
ANS1356E  
ANS1357S  
ANS1358S  
ANS1359E  
Session rejected: Server disabled  
Explanation: The server is in a disabled state and cannot be accessed for normal  
activity.  
System Action: TSM canceled the current operation.  
User Response: Retry the operation after the server returns to an enabled state. If  
the problem continues, see your system administrator.  
The server is not configured to allow open registration  
Explanation: No authorization. Registration is required by your system  
administrator. The server is not configured to allow open registration.  
System Action: Session not started.  
User Response: You must obtain a TSM node and password from your system  
administrator.  
Session rejected: Downlevel client code version  
Explanation: The server version and your client version do not match. The client  
code is downlevel.  
System Action: TSM canceled the current operation.  
User Response: See your system administrator to see what version of TSM to run  
for your location.  
Session rejected: Downlevel server code version  
Explanation: The server version and your client version do not match. The server  
code is downlevel.  
System Action: TSM canceled the current operation.  
User Response: See your system administrator to see what version of TSM to run  
for your location.  
Session Rejected: The specified node name is currently in use  
Explanation: The node name you specified is in use on the server.  
System Action: Session was not started.  
User Response: The server is probably performing a task that prevents your node  
from establishing a session. Retry later or check with your system administrator.  
Tivoli Storage Manager Messages  
1129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1361E  
ANS1362S  
Session Rejected: The specified node name is currently locked  
Explanation: The node name you specified is currently locked on the server.  
System Action: Session was not started.  
User Response: Check with your system administrator to find out why your node  
name is locked.  
SLM LICENSE EXCEEDED: The client licenses for TSM are exceeded. See  
your system administrator.  
Explanation: Adding a new enrollment will exceed the product license count for  
TSM.  
System Action: Execution of the client enrollment or connection request ends.  
User Response: See your system administrator.  
ANS1363E  
ANS1364E  
Session Rejected: The server does not have enough memory to allow a  
connection to be established.  
Explanation: The server does not have enough memory to allow your client to  
establish a connection with the server.  
System Action: Session was not started.  
User Response: Retry later or see your system administrator.  
Session Rejected: The server does not have enough recovery log space to allow  
a connection to be established.  
Explanation: The server ran out of recovery log space.  
System Action: Session was not started.  
User Response: This error is a temporary problem. Retry later or see your system  
administrator.  
ANS1365E  
ANS1366E  
Session Rejected: The server does not have enough database space to allow a  
connection to be established.  
Explanation: The server ran out of database space.  
System Action: Session was not started.  
User Response: See your system administrator.  
Session Rejected: The server has an internal error  
Explanation: The client cannot establish a connection to the server because of an  
internal server error.  
System Action: Session was not started.  
User Response: See your system administrator immediately.  
1130  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1367E  
ANS1368S  
Session Rejected: The server does not allow a signon as a Unicode enabled  
client  
Explanation: The client can not establish a connection to the server because of a  
unicode enabling mismatch between server and client.  
System Action: Session was not started.  
User Response: See your system administrator immediately.  
Session Rejected: The server is not licensed for this platform type. See your  
system administrator.  
Explanation: The server is not licensed for the requesting client type.  
System Action: Execution of the client enrollment or connection request ends.  
User Response: See your system administrator.  
ANS1369W  
ANS1370E  
Session Rejected: The session was canceled by the server administrator.  
Explanation: The server administrator canceled the current client session.  
System Action: Execution of the client connection request ends.  
User Response: See your system administrator.  
The user ID entered does not have the correct level of authority to access the  
client machine.  
Explanation: The user ID entered cannot access this TSM client.  
System Action: The TSM operation ends.  
User Response: Grant authority to this user ID on the TSM server so that it can  
access this TSM client.  
ANS1371E  
ANS1400E  
Unable to reconstruct ’’ from subfile components.  
Explanation: An error occurred while reconstructing this file from its subfile  
components.  
System Action: Processing stopped.  
User Response: Please check error log for more information.  
TSM encounters a TLI error  
Explanation: TSM encounters a TLI error. A more detailed description of the error  
may be found in the log file. This error only applies when using IPX/SPX  
communications.  
System Action: The client terminates.  
User Response: See your system administrator with the log file.  
ANS1401E  
Session rejected: IPX/SPX connection failure  
Explanation: An attempt to connect to the server using IPX/SPX communications  
failed. The server address is incorrect, or the server is not up, or a system error has  
occurred. This error only applies when using IPX/SPX communications.  
Tivoli Storage Manager Messages  
1131  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Session is not established.  
User Response: Check your server address and make sure that the server is up and  
running. Retry the operation, and if the problem continues, shut down the system,  
reboot and retry the operation. If the problem continues, see your system  
administrator.  
ANS1402E  
ANS1403E  
ANS1404E  
ANS1450E  
TLI.DLL not found in search path  
Explanation: TSM cannot find the TLI DLL in the current search path. This error  
only applies when using IPX/SPX communications.  
System Action: Session is not established.  
User Response: Place the directory where this file resides in the path statement.  
Shut down the system and reboot.  
Error loading TLI.DLL  
Explanation: An error occurs while loading the TLI.DLL into memory. This error  
only applies when using IPX/SPX communications.  
System Action: Session is not established.  
User Response: This error is caused by insufficient memory. Shut down the  
system and reboot. If the problem continues, see your system administrator.  
Error loading one or more functions from the TLI.DLL  
Explanation: An error occurs while loading one or more functions from the  
TLI.DLL file. This error only applies when using IPX/SPX communications.  
System Action: Session is not established.  
User Response: This error is caused by insufficient memory. Shut down the  
system and reboot. If the problem continues, see your system administrator.  
APPC unable to allocate conversation.  
Explanation: The client is unable to allocate an APPC conversation to the server.  
System Action: The client terminates.  
User Response: Ensure that the partner LU name and transaction program name in  
the client configuration file (dsm.opt) are correct. See your system administrator to  
get the proper partner LU name and transaction program name.  
ANS1451E  
ANS1452E  
APPC deallocate error.  
Explanation: TSM receives an incorrect return code from the deallocate verb. This  
error does not affect the TSM program.  
System Action: None.  
User Response: None.  
APPC missing LU name.  
Explanation: A logical unit name is necessary to complete the operation.  
System Action: Processing stops.  
1132  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Retry the operation using the PARTNERLUNAME option.  
ANS1453E  
ANS1454E  
APPC missing TP name.  
Explanation: A transaction program name is necessary to complete the operation.  
System Action: Processing stops.  
User Response: Retry the operation using the TPNAME option.  
APPC parameter error.  
Explanation: A parameter to an APPC communication call is in error.  
System Action: Processing stops.  
User Response: This usually indicates that an invalid transaction program name  
has been given. Check this value and retry.  
ANS1455E  
APPC product specific error.  
Explanation: TSM detects an error that occurs when making an APPC  
communication call.  
System Action: Processing stops.  
User Response: Be sure that LU6.2 is working properly at your installation.  
Contact your support personnel.  
ANS1456E  
ANS1457E  
APPC program error.  
Explanation: An unexpected APPC communication error occurs.  
System Action: Processing stops.  
User Response: This is a program error. Contact your support personnel.  
APPC program parameter check.  
Explanation: A parameter to an APPC communication call is in error.  
System Action: Processing stops.  
User Response: An invalid transaction program name has been given. Check this  
value in the client configuration file (dsm.opt) and retry.  
ANS1458E  
ANS1459E  
APPC program state check.  
Explanation: An unexpected APPC communication error occurs.  
System Action: Processing stopped.  
User Response: This is a program error. Contact your support personnel.  
APPC resource error.  
Explanation: The conversation ends prematurely.  
System Action: Processing stops.  
User Response: Exit TSM and retry the TSM command.  
Tivoli Storage Manager Messages  
1133  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1460E  
ANS1461E  
APPC security not valid.  
Explanation: The conversation cannot be allocated because the access security is  
incorrect.  
System Action: Processing stops.  
User Response: Contact your support personnel. information table.  
APPC sync level not supported.  
Explanation: The conversation cannot continue because the synchronization level  
of either the local or remote system is not supported.  
System Action: Processing stops.  
User Response: TSM defaults to no synchronization level. Contact your system  
administrator.  
ANS1462E  
ANS1463E  
APPC TPN not recognized.  
Explanation: TSM cannot find the name of the server.  
System Action: Processing stops.  
User Response: Ensure that the TPNAME option references the correct server  
name and that the server is running.  
APPC TP error.  
Explanation: The server is not responding to the local program’s request.  
System Action: Processing stops.  
User Response: Ensure that the server is running and retry. Stop and start the local  
communications program.  
ANS1464E  
ANS1465E  
ANS1466E  
APPC type mismatch.  
Explanation: An unexpected APPC communication error occurs.  
System Action: Processing stops.  
User Response: This is a program error. Contact your support personnel.  
APPC unsuccessful.  
Explanation: All the sessions for SNA communications have been exhausted.  
System Action: Processing stops.  
User Response: Stop and start SNA communications and retry the command.  
APPC unknown error occurred.  
Explanation: An unexpected APPC communication error occurs.  
System Action: Processing stops.  
User Response: Contact your support personnel.  
1134  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1467E  
ANS1468E  
APPC insufficient memory.  
Explanation: There is insufficient memory to perform the requested APPC  
function.  
System Action: Processing stops.  
User Response: Shut down running applications and retry. If the problem persists,  
contact your support personnel.  
The APPC router is not installed.  
Explanation: A connection to the server cannot be established because the Client  
Access/400 or PC Support/400 router is not installed.  
System Action: Connection to server fails.  
User Response: Install the Client Access/400 or PC Support/400 router and retry  
the command.  
ANS1469E  
ANS1470E  
Error processing ’filespace namepath-namefile-name’: invalid encryption key  
Explanation: Key entered does not match the key used for the backed up file.  
System Action: Processing stopped.  
User Response: Recollect the key used for backup.  
The APPC router installed does not support the Windows API.  
Explanation: A connection to the server cannot be established because a Client  
Access/400 or PC Support/400 router supporting Windows is not installed.  
System Action: Connection to server fails.  
User Response: Install the correct version of the Client Access/400 or PC  
Support/400 router and retry the command.  
ANS1471E  
ANS1473E  
PCSWIN is not loaded.  
Explanation: A connection to the server cannot be established because the Client  
Access/400 or PC Support/400 program PCSWIN is not loaded.  
System Action: Connection to server fails.  
User Response: Load PCSWIN and retry the command.  
Session rejected: TCP/IP connection failure for Shared Memory  
Explanation: An attempt to connect to the local server using the Shared Memory  
protocol has failed during initial TCP/IP communications. This error can occur if the  
server is not listening on the correct port, or if the server is down.  
System Action: Session rejected. Processing stopped.  
User Response: Retry the operation, or wait until the server comes back up and  
retry the operation. If the problem continues, see your system administrator for  
further help.  
Tivoli Storage Manager Messages  
1135  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1474E  
ANS1475E  
An error occurred using the Shared Memory protocol  
Explanation: An error has occurred while reading or writing data through the  
Shared Memory communications protocol.  
System Action: TSM cannot complete the requested operation.  
User Response: Check the trace log for additional information and retry the  
operation. If the problem continues, see your system administrator for further help.  
Insufficient authority to connect to the shared memory region  
Explanation: The user issuing the command does not have authority to connect to  
the shared memory segment. When the shared memory segment is created by the  
server, it will be owned by the effective uid of the server process (dsmserv). Only  
processes running under this uid or root will be allowed to connect to the segment  
(and thus to the server).  
System Action: The session is rejected and processing stops.  
User Response: Run the command under the uid of the processing running  
dsmserv, if possible. Otherwise contact your system administrator for further help.  
ANS1500E  
ANS1501E  
Module dsmtca not found in secure directory.  
Explanation: TSM cannot find the Trusted Communication Agent module  
(dsmtca) in the appropriate directory.  
System Action: TSM ends.  
User Response: Log on as root user, then create a link to dsmtca module in  
/usr/bin with the command: ln -s /usr/tivoli/tsm/client/ba/bin/dsmtca /usr/bin/dsmtca  
Trusted agent execution/owner permissions are invalid  
Explanation: The Trusted Communication Agent execution/owner permissions are  
invalid.  
System Action: TSM ends.  
User Response: Have your system administrator check the installation instructions  
for the client to ensure that the Trusted Communication Agent permissions are set  
correctly. This error can be caused by installing TSM as a non-root user. For the  
UNIX platforms that have the installation program (dsm.install), you must run  
dsm.install while logged in as the root user.  
ANS1502E  
Access to system function required to run has been denied  
Explanation: The permissions of the Trusted Communication Agent do not allow  
it to be accessed by the user of the TSM client.  
System Action: TSM ends.  
User Response: See your system administrator.  
1136  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1503E  
Valid password not available for server ’server-name’. The administrator for  
your system must run TSM and enter the password to store it locally.  
Explanation: The file containing the stored password for the specified server  
server-name is unavailable.  
System Action: TSM ends.  
User Response: The administrator for your system must set and store a new  
password.  
ANS1504E  
Error starting the Trusted Communication Agent process.  
Explanation: An error has occurred starting the Trusted Communication Agent  
process; specifically, the fork() function has failed.  
System Action: TSM ends.  
User Response: Probable system error. If the problem persists, restart the  
workstation.  
ANS1505E  
ANS1506E  
Trusted Communication Agent has terminated unexpectedly.  
Explanation: The Trusted Communication Agent has terminated unexpectedly.  
System Action: TSM ends.  
User Response: Check the error log for more information. Retry the activity. If the  
problem persists, contact your service representative.  
Trusted Communication Agent received invalid request.  
Explanation: The Trusted Communication Agent has received an unknown request  
from the TSM client.  
System Action: TSM ends.  
User Response: Internal error. If the problem recurs, contact your service  
representative.  
ANS1507E  
ANS1508E  
This action requires TSM administrative authority on this system.  
Explanation: An activity has been attempted that must be performed by the TSM  
administrator (for example, open registration, filespace delete or password update).  
System Action: TSM ends.  
User Response: If the activity is required, the administrator for this system must  
perform it.  
Error allocating semaphores.  
Explanation: An error has occurred because the semaphores you are attempting to  
allocate have become insufficient.  
System Action: Processing ends.  
User Response: Ask your system administrator for assistance, and possibly  
increase the number of semaphores in your system.  
Tivoli Storage Manager Messages  
1137  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1509E  
ANS1510E  
ANS1513E  
ANS1514E  
Error setting semaphore value or waiting on semaphore.  
Explanation: An error has occurred while attempting to set or wait on a  
semaphore.  
System Action: Processing ends.  
User Response: Probable system error. If the problem persists, restart the  
workstation.  
Trusted Communications Agent error attaching shared memory.  
Explanation: An error has occurred while attaching the trusted agent’s shared  
memory.  
System Action: Return to caller.  
User Response: Stop application, check shared memory usage and retry the  
command. Read the tca.log file for the system error number.  
Invalid trace keyword - ’keyword’. Please reenter traceflags.  
Explanation: A TRACEFLAG option in the user configuration file or on the  
command line is incorrect.  
System Action: Tracing was not enabled.  
User Response: Correct the value. See the entry for TRACEFLAGS in the Trace  
Facility Guide document for a list of valid trace flags.  
Invalid trace keyword. Please reenter traceflags.  
Explanation: A TRACEFLAG option in the user configuration file or on the  
command line is incorrect.  
System Action: Tracing was not enabled.  
User Response: Correct the value. See the entry for TRACEFLAGS in the Trace  
Facility Guide document for a list of valid trace flags.  
ANS1822S  
ANS1823E  
Option ’option-name’ is ignored. Processing Continues.  
Explanation: The specified option in the options file is invalid for this version of  
the backup client executable.  
System Action: None.  
User Response: Either remove this option or ignore the message.  
Invalid trace keyword - ’keyword’  
Explanation: A TRACEFLAG option in the user configuration file or on the  
command line is incorrect.  
System Action: Client program did not initialize or tracing was not enabled in the  
applet.  
User Response: Correct the value. See the entry for TRACEFLAGS in the Trace  
Facility Guide document for a list of valid trace flags.  
1138  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1824E  
ANS1825E  
ANS1826E  
Invalid trace file name (name too long).  
Explanation: A TRACEFILE option in the preferences files used a file name that  
is too long.  
System Action: Client program did not initialize.  
User Response: Change the file name used as the TRACEFILE so that it is equal  
to or less than 255 characters in length.  
Unable to close trace output file file-name.  
Explanation: An error occurred during the closing of a trace output file-name (for  
example, not enough disk space).  
System Action: Processing continues.  
User Response: Check the options.doc file for a description of possible causes of  
the error, or see your system administrator.  
Unable to open trace output file file-name.  
Explanation: A TRACEFILE option in the user configuration file or on the  
command line used a directory path and file-name combination to which you do not  
have write access.  
System Action: Client program did not initialize.  
User Response: Change the TRACEFILE value so that it is a location to which  
you have write access.  
ANS1827E  
ANS1828E  
ANS1830E  
You are editing the file, file-name. Please save it and press ’Enter’ to continue,  
or ’q’ to exit.  
Explanation: You are editing the specified file-name.  
System Action: None.  
User Response: Save the file and press Enter to continue, or enter ‘q’ to quit the  
file.  
Screen size is too small for using the PICK option.  
Explanation: You cannot use the PICK option on a workstation that has a screen  
smaller than 20 characters across and 10 lines down.  
System Action: TSM did not complete the operation.  
User Response: Retry the operation using a workstation that has a screen with the  
minimum size, or do not use the PICK option.  
Unable to write to trace file tracefile. Tracing disabled.  
Explanation: An error occurred when writing to the specified tracefile.  
System Action: Tracing is disabled. Processing continues.  
User Response: Ensure the device that the tracefile access is available and has  
sufficient space for the tracefile. Retry the command.  
Tivoli Storage Manager Messages  
1139  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1831E  
ANS1832S  
Password expired. The administrator for this system must run TSM to update  
the password.  
Explanation: The password expired.  
System Action: TSM ends.  
User Response: The administrator for this system must update the password.  
Unable to send generated password using MailProg ’option’  
Explanation: TSM cannot send the file containing the generated password to the  
user ID specified in the MailProg option.  
System Action: TSM ends.  
User Response: Have your service representative check the error log for reasons  
why the file was not sent to the user ID.  
ANS1833S  
ANS1834S  
ANS1835E  
Unable to create ’directory-name’ directory for storing passwords  
Explanation: TSM cannot create the specified directory-name.  
System Action: Processing continues.  
User Response: Check to see if you have enough disk space and retry the  
operation. If unsuccessful, see your system administrator.  
Unable to write to ’file-name’ for storing password  
Explanation: TSM cannot write to the specified file-name.  
System Action: Processing continues.  
User Response: Check access permissions and disk space. If unsuccessful, see  
your system administrator.  
PASSWORDACCESS is GENERATE, but password needed for server  
server-name’. Either the password is not stored locally, or it was changed at the  
server.  
Explanation: Either the password is not stored locally, or it was changed at the  
server.  
System Action: TSM prompts you for the password if TSM is running in the  
foreground.  
User Response: If TSM was running as a background process, issue any TSM  
command from the foreground. Enter the password in answer to the prompt. Then  
try your background TSM command again.  
ANS1836S  
MailProg file-name failed with return code = value.  
Explanation: An error occurred with the specified MailProg file-name.  
System Action: TSM ends.  
User Response: Check the return code for the MailProg file-name. See your  
system administrator if you are unable to resolve the problem.  
1140  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1837S  
File space filespace-name is ignored. Processing continues.  
Explanation: The specified filespace-name in the system options file is invalid.  
System Action: TSM attempts to continue the current operation.  
User Response: Check the file space in the system options file and use a valid file  
space. Retry the operation.  
ANS1838E  
ANS1839E  
Error opening user specified options file ’filespace-name’ .  
Explanation: The specified options file-name could not be located or opened.  
System Action: TSM attempts to open default option file.  
User Response: Make sure specified option file exists and is valid.  
Cannot read password.  
Explanation: An error occurred in setting up the input file (for example, the  
terminal) to be read.  
System Action: Processing stopped.  
User Response: Check the attributes of the terminal.  
ANS1841I  
ANS1842S  
Attempting to open default options file ...  
Explanation: TSM is attempting to open the default options file.  
System Action: Processing continues.  
User Response: None.  
Session rejected: SNALU6.2 connection failure. CPIC unable to allocate  
conversation  
Explanation: TSM client cannot allocate a CPIC conversation to the server.  
System Action: Processing stopped.  
User Response: Ensure that the symbolic destination name matches a valid side  
information table entry in your local communications program.  
ANS1843S  
ANS1844S  
Session rejected: SNALU6.2 connection failure. CPIC conversation type  
mismatch between the client and the server.  
Explanation: An unexpected CPIC error occurred. There is a CPIC conversation  
type mismatch between the client and the server.  
System Action: Processing stopped.  
User Response: This is a program error. See your service representative.  
Session rejected: SNALU6.2 connection failure. CPIC PIP not specified  
correctly  
Explanation: An unexpected CPIC error occurred. The CPIC PIP is not specified  
correctly.  
System Action: Processing stopped.  
User Response: This is a program error. See your service representative.  
Tivoli Storage Manager Messages  
1141  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1845S  
ANS1846S  
Session rejected: SNALU6.2 connection failure. CPIC security not valid  
Explanation: The conversation cannot be allocated because the CPIC security is  
not valid.  
System Action: Processing stopped.  
User Response: Change the security in the CPIC side information table.  
Session rejected: SNALU6.2 connection failure. CPIC synchronization level not  
supported  
Explanation: The conversation cannot continue because the CPIC synchronization  
level of either the local or remote system is not supported.  
System Action: Processing stopped.  
User Response: TSM defaults to no synchronization level. See your service  
representative.  
ANS1847S  
Session rejected: SNALU6.2 connection failure. CPIC transaction program  
name not recognized  
Explanation: CPIC transaction program name not recognized. TSM cannot find  
the name of the server.  
System Action: Processing stopped.  
User Response: Ensure that you have the correct TSM server name listed in your  
CPIC side information entry and that the server is running.  
ANS1848S  
Session rejected: SNALU6.2 connection failure. CPIC transaction program not  
available.  
Explanation: CPIC transaction program not available. The server is not responding  
to the local program’s request.  
System Action: Processing stopped.  
User Response: Ensure that the server is running and retry the command. Stop and  
start the local communications program.  
ANS1849S  
ANS1850S  
Session rejected: SNALU6.2 connection failure. CPIC parameter error  
Explanation: A parameter to a CPIC call was in error.  
System Action: Processing stopped.  
User Response: An invalid symbolic destination or invalid transaction program  
name was given. Check these values and retry the command.  
Session rejected: SNALU6.2 connection failure. CPIC product-specific error.  
Explanation: TSM detected a CPIC product-specific error that occurred when  
making a CPIC call.  
System Action: Processing stopped.  
User Response: Ensure that LU6.2 is working properly at your installation. See  
your system administrator.  
1142  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1851S  
ANS1852S  
Session rejected: SNALU6.2 connection failure. CPIC program error.  
Explanation: An unexpected CPIC program error occurred.  
System Action: Processing stopped.  
User Response: This is a program error. See your service representative.  
Session rejected: SNALU6.2 connection failure. CPIC resource error  
Explanation: CPIC resource error. The conversation ended prematurely.  
System Action: Processing stopped.  
User Response: Exit TSM and retry the TSM command. API applications should  
close the session with dsmTerminate.  
ANS1853W  
Session rejected: SNALU6.2 connection failure. CPIC conversation deallocation  
error  
Explanation: CPIC conversation deallocation error. TSM received an incorrect  
return code from the deallocate verb. This error does not affect the TSM program.  
System Action: None.  
User Response: None.  
ANS1854S  
ANS1855S  
Session rejected: SNALU6.2 connection failure. CPIC SVC error  
Explanation: A CPIC SVC error occurred.  
System Action: Processing stopped.  
User Response: See your service representative.  
Session rejected: SNALU6.2 connection failure. CPIC conversation has been  
lost  
Explanation: The CPIC conversation no longer exists.  
System Action: Processing stopped.  
User Response: Retry the TSM command.  
ANS1856S  
ANS1857S  
Session rejected: SNALU6.2 connection failure. CPIC program parameter  
check  
Explanation: A parameter to a CPIC call was in error.  
System Action: Processing stopped.  
User Response: An invalid symbolic destination or invalid transaction program  
name was given. Check these values and retry the command.  
Session rejected: SNALU6.2 connection failure. CPIC program state check  
Explanation: CPIC program state check.  
System Action: Processing stopped.  
User Response: This is a program error. See your service representative.  
Tivoli Storage Manager Messages  
1143  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1858S  
ANS1859S  
Session rejected: SNALU6.2 connection failure. CPIC session not immediately  
available  
Explanation: CPIC session not immediately available. All the sessions for SNA  
communications are in use.  
System Action: Processing stopped.  
User Response: Stop and start SNA communications and retry the command.  
Session rejected: SNALU6.2 connection failure. CPIC: You must supply an  
PARtnerluname if no SYMbolicdestination given.  
Explanation: For CPIC, you must supply a PARtnerluname if no  
SYMbolicdestination is given.  
System Action: Processing stopped.  
User Response: Retry the operation using an LU name or a symbolic destination  
name.  
ANS1860S  
Session rejected: SNALU6.2 connection failure CPIC: You must supply a  
TPname if no SYMbolicdestination given.  
Explanation: For CPIC, you must supply a TPname if no SYMbolicdestination is  
given.  
System Action: Processing stopped.  
User Response: Retry the operation using the TPname option or define the  
SYMbolicdestination option.  
ANS1865E  
Session rejected: Named Pipes connection failure.  
Explanation: An attempt to connect to the server using Named Pipes  
communications failed. This might have occurred if an incorrect  
NAMEDPIPENAME was specified in the options files or if your system  
administrator canceled a backup operation.  
System Action: Processing stopped.  
User Response: Retry the operation, or wait until the server comes back up and  
retry the operation. Ensure that the value specified on the NAMEDPIPENAME  
option is the same as the one used by the server. If the problem continues, contact  
your system administrator for further help.  
ANS1056E  
Share/network path cannot be resolved. Path does not exist. Specify a  
destination or restore the directory first.  
Explanation: Trying to restore to a share/network path that can’t be resolved. The  
directory path does not exist. Retry the command and specifying a destination or  
restore the directory tree first before trying to restore the share point.  
System Action: Processing stopped.  
User Response: None.  
1144  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1071E  
ANS1072E  
Invalid domain name entered: ’domain-name’  
Explanation: You entered an invalid domain-name.  
System Action: Processing stopped.  
User Response: Enter a valid drive or file system name (domain).  
Unable to continue operation; Drive ’drive-name’ has no volume label.  
Explanation: The specified drive-name in the domain list does not have a volume  
label.  
System Action: Processing stopped.  
User Response: Use the system format utility to place a unique volume label on  
all drives on which you intend to run TSM.  
ANS1092E  
No files matching search criteria were found  
Explanation: You entered a search pattern or file name that cannot be found in the  
server database.  
System Action: Processing stopped.  
User Response: Ensure that your search pattern is correct, or specify a new search  
string.  
ANS1095I  
ANS1096S  
Specified directory branch structure has been restored  
Explanation: The specified directory branch was successfully restored.  
System Action: TSM restored the directory branch.  
User Response: Continue with normal operations.  
Either an Active Policy Set or a node was not found on the server; Unable to  
proceed  
Explanation: Either no Active Policy Set data was found on the server or a  
fromnode option contained a nodename not found on the server.  
System Action: Processing stopped.  
User Response: See your system administrator.  
ANS1103E  
ANS1130E  
Invalid management class entered  
Explanation: You entered an invalid management class.  
System Action: TSM is unable to do the requested operation.  
User Response: Retry the operation using a valid management class.  
Unable to continue operation. Drive has no label.  
Explanation: The selected drive does not have a label.  
System Action: TSM is unable to do the requested operation without a drive or  
label entered.  
Tivoli Storage Manager Messages  
1145  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If the drive is a floppy drive, place a disk with a volume label in  
it and retry the operation. If the disk is a hard drive, ensure the drive has a volume  
label, and retry the operation.  
ANS1134E  
ANS1135E  
Drive drive-name is an invalid drive specification  
Explanation: The specified drive-name was found to be invalid; the drive  
probably has not been defined.  
System Action: TSM skips the invalid drive and continues to the next drive.  
User Response: Check the invalid drive.  
Drive drive-name1 is a virtual drive of drive-name2 Not a valid drive to be  
backed up  
Explanation: The drive-name1 was found to be a substitute (SUBST) of another  
drive-name2. It is not available for backup/archive.  
System Action: TSM skips the SUBST drive and continues to the next drive.  
User Response: None.  
ANS1147E  
ANS1190E  
File is temporarily unavailable.  
Explanation: File is temporarily unavailable.  
System Action: File skipped.  
User Response: Check and see if file is locked by other process. If not, retry the  
command.  
Symbolic link ’linkname’ to ’target’ was successfully deleted.  
Explanation: Log ’linkname’ cannot be a symbolic link.  
System Action: The symbolic link ’linkname’ is deleted, the log is recreated, and  
processing stops.  
User Response: Check the location of the new file. To specify the location of log  
files, refer to the user’s manual for the ’errorlogname’ option, the ’schedlogname’  
option, and the ’DSM_LOG’ environmental variable.  
ANS1191E  
ANS1192E  
Unable to delete symbolic link ’link’.  
Explanation: Log ’linkname’ cannot be a symbolic link.  
System Action: Processing stops.  
User Response: Delete the symbolic link ’linkname’.  
Specifying the error log ’link’ as a symbolic link is not allowed.  
Explanation: Error log ’linkname’ cannot be a symbolic link.  
System Action: The symbolic link ’linkname’ is deleted, the error log is recreated,  
and processing stops.  
User Response: Check the location of the new error log. To specify the location of  
the error logs, refer to the user’s manual for the ’errorlogname’ option and  
’DSM_LOG’ environmental variable.  
1146  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1193E  
ANS1194E  
Specifying the trace file ’link’ as a symbolic link is not allowed.  
Explanation: Trace file ’linkname’ cannot be a symbolic link.  
System Action: The symbolic link ’linkname’ is deleted, the trace file is recreated,  
and processing stops.  
User Response: Specify the trace file location with the ’tracefile’ option.  
Specifying the schedule log ’link’ as a symbolic link is not allowed.  
Explanation: Schedule log ’linkname’ cannot be a symbolic link.  
System Action: The symbolic link ’linkname’ is deleted, the schedule log is  
recreated, and processing stops.  
User Response: Check the location of the new schedule log. To specify the  
location of the schedule log, refer to the user’s manual for the ’schedlogname’  
option.  
ANS1216E  
Not authorized to run TSM. See the administrator for your system.  
Explanation: The system options file for the server that you are attempting to  
connect to contains a user entry, a group entry, or both a user and group entry. Your  
user ID, or group ID, was not found in any of the entries. You are currently not  
authorized to run TSM to this server.  
System Action: TSM initialization fails and the program ends.  
User Response: See the TSM administrator for your system, and ask to be added  
to the user or group list for this server.  
ANS1217E  
ANS1218E  
Server name not found in System Options File  
Explanation: The system options file does not contain the SERVERNAME option.  
System Action: TSM initialization fails and the program ends.  
User Response: See the TSM administrator for your system, and make sure that  
the system options file contains the server name.  
TCPSERVERADDRESS not defined for this server in the System Options File  
Explanation: The TCPSERVERADDRESS for this server is not defined in the  
server name stanza in the system options file.  
System Action: TSM initialization fails and the program ends.  
User Response: See the TSM administrator for your system, and make sure that  
the server to which you are trying to connect, has a valid TCPSERVERADDRESS  
defined in the system options file.  
ANS1219E  
NODENAME cannot be the same as HostName  
Explanation: The NODENAME defined in the options file cannot be the same as  
the system HostName.  
System Action: Initialization fails and the program ends.  
User Response: See your system administrator or the root user.  
Tivoli Storage Manager Messages  
1147  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1230E  
ANS1237E  
ANS1238S  
ANS1256E  
Stale NFS File Handle  
Explanation: An NFS file system becomes stale.  
System Action: File system skipped.  
User Response: Check the NFS mounted filesystem.  
Server problem. Please see error log.  
Explanation: This is a server problem.  
System Action: Processing stopped.  
User Response: Have your service representative check the error log.  
Internal Error. Please see error log.  
Explanation: Server problem. Invalid policy binding.  
System Action: Processing stopped.  
User Response: Have your service representative check the error log.  
Cannot make file/directory  
Explanation: The directory path for files being restored or retrieved cannot be  
created.  
System Action: File skipped.  
User Response: Ensure that you have the proper authorization to create the  
directory for file being restored or retrieved. Make sure that you have write access.  
ANS1265E  
Encountered bad mount or filesystem, processing stopped.  
Explanation: The getmnt system call returned an error indication. Error was  
encountered trying to determine what the mounted file systems are.  
System Action: Processing stopped. Cannot recover.  
User Response: There is a bad file system or mount point on your system. Look  
at file systems and mounts, and correct any errors. If unsuccessful, see your system  
administrator for more information.  
ANS1266E  
Encountered bad mount or filesystem, processing stopped.  
Explanation: An error was encountered trying to determine what the mounted file  
systems are.  
System Action: Processing stopped. Cannot recover.  
User Response: There is a bad filesystem or mount point on your system. Look at  
file systems and mounts, and correct any errors. If you used to have an FSM (HSM)  
file system but then removed HSM from it, make sure that there is no FSM mount  
for that filesystem; if it is still there then unmount it. If unsuccessful, see your  
system administrator for more information.  
1148  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1267E  
The management class for file file-name does not allow migration. This file will  
not be migrated.  
Explanation: The management class for this file does not allow migration  
System Action: File is skipped.  
User Response: Either have the TSM administrator change the Space Management  
Technique within the management class to a value other than NONE or change the  
include/exclude list to specify a management class with the appropriate Space  
Management Technique value.  
ANS1410E  
Unable to access the network path.  
Explanation: The network path cannot be accessed due to a possible network  
problem.  
System Action: The client terminates.  
User Response: Ensure that the network is up and the path can be accessed using  
a system command, and retry the operation.  
ANS1411E  
ANS1412E  
ANS1861E  
A communication session was dropped.  
Explanation: A communication session was dropped due to a possible network  
problem.  
System Action: The client terminates.  
User Response: Ensure that the network is up and retry the operation.  
Directory or file has bad EA data or inconsistent data.  
Explanation: Directory or file has bad EA data or inconsistent data.  
System Action: The client terminates.  
User Response: Check failing directory or file for bad EA data. Copy the directory  
to a new location and retry the operation.  
Error loading the SNA Services/6000 CPIC routines.  
Explanation: TSM cannot load the SNA Services/6000 driver file. This message  
only applies when using CPI Communications via SNA Services/6000.  
System Action: Connection to the server fails.  
User Response: Make sure the SNA Services/6000 CPI Communications library  
file, ’/usr/lib/libcpic.a’, exists. This file is installed when SNA Services/6000 was  
installed. Also, make sure the TSM SNA Services/6000 driver file, dsmsna.drv,  
exists in the TSM installation directory.  
ANS1904E  
The archive description may not contain any wildcard characters like ’?’ or ’*’.  
Explanation: Descriptions for archive files must not contain wildcard characters.  
System Action: Processing stopped.  
User Response: Enter an archive description that does not contain wildcard  
characters.  
Tivoli Storage Manager Messages  
1149  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1933E  
ANS1934E  
ANS13375E  
Error accessing file or device ’name’.  
Explanation: An error has occurred while accessing the file or device.  
System Action: Backup set operation is not completed.  
User Response: Verify that the file or device exists and is accessible.  
Backup set ’name’ not found.  
Explanation: The backup set name was not found on the server.  
System Action: The backup set operation is not processed.  
User Response: Verify that the backup set name is correct.  
Session Rejected: The specified user id is currently locked  
Explanation: The user id you specified is currently locked on the server.  
System Action: Session was not started.  
User Response: Check with your system administrator to find out why your user  
id is locked.  
1150  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Command–Line Client Messages  
(1053–3999)  
ANS1053I  
Existing filespace name filespace-name has been renamed to filespace-name  
Explanation: The existing filespace name using the volume label has been  
renamed to the UNC format naming convention.  
System Action: Processing continues.  
User Response: None.  
ANS1054E  
Unable to rename existing filespace filespace-name to new filespace  
filespace-name.RC=retcode from cuFSUpd().  
Explanation: Unable to rename the existing filespace name using the volume label  
to the UNC format naming convention.  
System Action: Processing stopped.  
User Response: None.  
ANS1055I  
Trying to rename existing filespace filespace-name to new filespace  
filespace-name, but drive letters do not match, old=drive-letter, new=drive-letter.  
Ignore the old filespace and backup to the new filespace.  
Explanation: Trying to rename the existing filespace name using the volume label  
to the UNC format naming convention but the drive letters do not match. Leave the  
existing filespace alone and create a new filespace.  
System Action: Processing continues.  
User Response: None.  
ANS1057I  
Trying to rename existing filespace filespace-name to new filespace  
filespace-name, but both filespaces exist. Ignore the old filespace and backup to  
the new filespace.  
Explanation: Trying to rename the existing filespace name using the volume label  
to the UNC format naming convention but both filespaces exists. Leave the existing  
filespace alone and backup to the new filespace.  
Tivoli Storage Manager Messages  
1151  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
System Action: Processing continues.  
User Response: None.  
ANS1073E  
File space correspondence for domain ’domain-name’ is not known  
Explanation: The number defining the correspondence between drive letter or file  
(domain name) and volume label is not known to the server.  
System Action: Processing stopped.  
User Response: Report the program error to your service representative.  
ANS1074I  
ANS1075E  
*** User Abort ***  
Explanation: An abort signal to stop an operation was received.  
System Action: Processing stopped.  
User Response: Continue with normal operations.  
*** Program memory exhausted ***  
Explanation: The program has exhausted all available storage.  
System Action: Processing stopped.  
User Response: Free any unnecessary programs, for example, terminate and stay  
resident programs (TSRs), that are running and retry the operation. Reducing the  
scope of queries and the amount of data returned can also solve the problem.  
ANS1076E  
ANS1077E  
ANS1078S  
*** Directory path not found ***  
Explanation: You specified an incorrect directory path.  
System Action: Processing stopped.  
User Response: Correct the syntax specified and retry the operation.  
ARCHMC Keyword is only valid for the ARCHIVE subcommand  
Explanation: You entered an incorrect subcommand for the keyword ARCHMC.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
*** Unknown system error error-code; program ending ***  
Explanation: An unknown and unexpected error-code occurred within the client  
program. This is a programming failure and the client program ends.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your  
administrator.  
ANS1079E  
No file specification entered  
Explanation: You did not enter a file specification as prompted.  
System Action: TSM did not continue with the requested operation.  
User Response: Enter a file specification to continue.  
1152  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1080E  
ANS1081E  
Unable to continue backup; Drive ’drive-name’ has no label.  
Explanation: The specified drive-name being backed up does not have a volume  
label.  
System Action: TSM cannot complete the requested operation.  
User Response: Use the system format utility to place a unique volume label on  
this drive and all the drives on which you intend to run TSM.  
Invalid search file specification ’string’ entered  
Explanation: You entered a file specification or search string that contains  
incorrect characters or contains wildcard characters in the drive specification or file  
system name.  
System Action: Processing stopped.  
User Response: Enter a correct file specification as described in the appropriate  
Using the Backup-Archive Client book for the particular operating system.  
ANS1082E  
ANS1083E  
ANS1084E  
ANS1085E  
Invalid destination file specification ’file-name’ entered  
Explanation: You entered a destination file-name specification that contains  
incorrect characters or has wildcard characters in the specification.  
System Action: Processing stopped.  
User Response: Enter a correct file specification as described in the appropriate  
Using the Backup-Archive Client book for the particular operating system.  
No files have previously been archived for ’filespace-name’  
Explanation: You tried to retrieve files when no files for the specified drive or file  
system (filespace-name) were previously archived.  
System Action: Processing stopped.  
User Response: Ensure that the correct drive or file system was specified and that  
files are archived for you to retrieve.  
No files have previously been backed up for ’filespace-name’  
Explanation: You tried to restore files when no files for the specified drive or file  
system (filespace-name) were previously backed up.  
System Action: Processing stopped.  
User Response: Ensure that the correct drive or file system was specified and that  
files are backed up for you to restore.  
No memory available to store Archive Management Class override name  
Explanation: Not enough memory was available for the operation.  
System Action: Processing stopped.  
User Response: Retry the operation or restart the system with fewer programs in  
memory.  
Tivoli Storage Manager Messages  
1153  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1086E  
ANS1087E  
File not found during Backup, Archive or Migrate processing  
Explanation: The file being processed for backup, archive or migrate no longer  
exists on the client. Another process deleted the file before it could be backed up,  
archived or migrated by TSM.  
System Action: File skipped.  
User Response: None.  
Access to the specified file or directory is denied  
Explanation: Access to the specified file or directory is denied. You tried to read  
from or write to a file and you do not have access permission for either the file or  
the directory.  
System Action: Processing stopped.  
User Response: Ensure that you specified the correct file or directory name,  
correct the permissions, or specify a new location.  
ANS1088E  
ANS1089E  
ANS1090E  
File space ’filespace-name’ does not exist  
Explanation: The specified file space (domain) is incorrect or does not exist on  
the machine.  
System Action: Processing stopped.  
User Response: Retry the operation specifying an existing domain (drive letter or  
file system name).  
Destination directory path length exceeds system maximum  
Explanation: The path name specified plus the path name in the restored file  
name combine to create a name whose length exceeds the system maximum.  
System Action: Processing stopped.  
User Response: Specify a destination path that, when combined, is less than the  
system maximum.  
Unable to build directory branch; A file exists with the same name as a  
directory. Failing path was: ’path-name’.  
Explanation: TSM tried to create a directory path-name, but is unable to because  
a file exists that has the same name as a directory.  
System Action: Processing stopped.  
User Response: Remove the file that has the same name as the directory. Refer to  
the given failing path, and either remove or move the file that caused this problem  
and restart the restore/retrieve operation.  
ANS1091E  
Communications error with server during object query  
Explanation: An unexpected communications error occurred during an object  
query to the server.  
System Action: Processing stopped.  
1154  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Verify that communications are active between the client and  
server machines. Server outages, processor outages, and communication controller  
outages can cause this error.  
ANS1093E  
Server does not support point-in-time option.  
Explanation: The server to which you are connected, does not support point in  
time values.  
System Action: Processing stopped.  
User Response: Enter the command without specifying the point in time option.  
ANS1094I  
ANS1097E  
The EXPIRATION option is ignored. Processing continues  
Explanation: The EXPIRATION option on the ARCHIVE command is ignored.  
System Action: Processing continues.  
User Response: None.  
Unable to read help text  
Explanation: The Help facility cannot read the help text file.  
System Action: Processing stopped.  
User Response: Make sure the DSM_DIR environment variable points to the  
correct directory containing the current level of TSM program files.  
ANS1098E  
Process terminated; Program memory exhausted.  
Explanation: The program used all available storage.  
System Action: Processing stopped.  
User Response: Free any unnecessary programs (TSRs) that are running, and retry  
the operation. Reducing the scope of queries and the amount of data returned can  
also solve the problem.  
ANS1099E  
ANS1100E  
ANS1101S  
File ’filename’ not previously archived  
Explanation: You tried to give access to a file, which is not stored on the server.  
System Action: Processing stopped.  
User Response: Ensure that the correct filename is specified.  
File ’filename’ not previously backed up  
Explanation: You tried to give access to a file, which is not stored on the server.  
System Action: Processing stopped.  
User Response: Ensure that the correct filename is specified.  
Internal program error. Failing message value was value. Please see your  
service representative.  
Explanation: An unexpected catastrophic program failure occurred, indicated by  
value.  
Tivoli Storage Manager Messages  
1155  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your system  
administrator or service representative.  
ANS1102E  
Excessive number of command line arguments passed to the program!  
Explanation: This command processing routine received more operands than it  
can use. Query can contain only one file specification. Restore and Retrieve can  
contain two file specifications. Archive, Delete, and Selective can contain a  
maximum of 20 file specifications.  
System Action: Processing stopped.  
User Response: Reduce the number of arguments and retry the operation. For  
UNIX-based systems, ensure that you do not omit the quotes around pattern  
matching characters.  
ANS1104E  
The management class for this file does not have a valid archive copy group.  
This file will not be archived.  
Explanation: The management class for this file does not have an archive copy  
group specified. This file will not be archived.  
System Action: Processing stopped.  
User Response: Add a valid archive copy group to the management class, and  
then retry the operation.  
ANS1105E  
The management class for this file does not have a valid backup copy group.  
This file will not be backed up.  
Explanation: The management class for this file does not have a backup copy  
group specified. This file will not be backed up.  
System Action: Processing stopped.  
User Response: Add a valid backup copy group to the management class, and  
then retry the operation.  
ANS1107E  
ANS1108E  
Invalid option/value: ’option’  
Explanation: You specified an incorrect TSM option option.  
System Action: Processing stopped.  
User Response: Specify a correct TSM option as defined in the appropriate Using  
the Backup-Archive Client book for the particular operating system.  
Invalid option (option) for the function command  
Explanation: The option option was specified for a command or subcommand  
(function) that cannot make use of that option.  
System Action: Processing stopped.  
User Response: See the appropriate Using the Backup-Archive Client book for  
your operating system for correct use of the named option.  
1156  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1110E  
ANS1111E  
Unable to open Help file file-name  
Explanation: The Help facility cannot find the help file file-name.  
System Action: Processing stopped.  
User Response: Ensure that the DSM_DIR environment variable points to the  
correct directory containing the current level of TSM program files.  
Unable to get Help file table of contents  
Explanation: The Help facility cannot read the help text file, or the file is  
corrupted.  
System Action: Processing stopped.  
User Response: Make sure the DSM_DIR environment variable points to the  
correct directory containing the current level of TSM program files, and that the  
files are intact.  
ANS1112I  
One or more files will be stored on offline media  
Explanation: For the backup or archive operation, one or more files must be sent  
to offline storage media (generally tape). The wait time depends on your site’s  
offline storage management policies.  
System Action: TSM waits for offline storage media to become available and then  
continues.  
User Response: None.  
ANS1113I  
One or more requested files are stored on offline media  
Explanation: For the restore or retrieve operation, one or more files must be  
recalled from offline storage media (generally tape). The wait time depends on your  
site’s offline storage management policies.  
System Action: TSM waits for offline storage media to become available and then  
continues.  
User Response: None.  
ANS1114I  
Waiting for mount of offline media.  
Explanation: The server is waiting for the requested media to become available  
before the operation can continue.  
System Action: TSM waits for requested data.  
User Response: None.  
ANS1115W  
File ’file-namefile-namefile-name’ excluded by Include/Exclude list  
Explanation: You tried to back up or migrate a file (file-name) that was specified  
to be excluded from backup.  
System Action: TSM did not back up or migrate the file.  
User Response: Specify the file using the Include option and retry the operation.  
Tivoli Storage Manager Messages  
1157  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1116E  
ANS1117E  
ANS1118W  
ANS1119I  
ANS1120E  
Unable to read commands entered from keyboard. Exiting...  
Explanation: Unable to read commands entered from keyboard. TSM cannot  
process your intended command.  
System Action: Processing stopped.  
User Response: Ensure that you are entering a correct command.  
The PICK and LATEST options are not valid together  
Explanation: During a restore, PICK and LATEST options cannot be used  
together.  
System Action: Processing stopped.  
User Response: Try again using either the PICK or the LATEST option.  
Invalid file space number entered. Try again.  
Explanation: The number that represents a file space was incorrect while you  
were using the PICK option.  
System Action: TSM waits for your specification.  
User Response: Enter a correct file space number.  
Initiating the removal of ’filespace-name’ file space.  
Explanation: Indicates that file space deletion has started on the specified  
filespace-name.  
System Action: None.  
User Response: None.  
Removal of file space ’filespace-name’ failed  
Explanation: Deletion of the specified filespace-name failed.  
System Action: Processing stopped.  
User Response: Try again. If the problem continues, see your system administrator  
to delete the file space for you.  
ANS1121I  
Removal of file space ’filespace-name’ successfully completed.  
Explanation: TSM successfully deleted the specified filespace-name.  
System Action: None.  
User Response: None.  
ANS1122W  
File space ’filespace-name’ does not exist on the server. The file space might  
have been deleted by another client using your client’s node name or an  
administrator.  
Explanation: The specified filespace-name does not exist on the server. Your  
system administrator deleted the file space or another client using your client’s node  
name might have deleted it.  
System Action: None.  
1158  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: None.  
ANS1123E  
The vertical screen dimension is too small to display the Help directory.  
Increase your window height.  
Explanation: Execution of the HELP command requires space for both the user  
prompts and at least one line of the HELP directory.  
System Action: The help directory is not displayed, and the help command cannot  
complete.  
User Response: Increase the size of your display window to allow more rows of  
text to be displayed.  
ANS1125E  
ANS1126E  
Unmatched Quotes: ’string’  
Explanation: The quotes specified in the pattern are not the same and do not  
make a set.  
System Action: Processing stopped.  
User Response: Correct the pattern using matching quotes in the syntax.  
Unable to delete the file space because this node does not have permission to  
delete archived data and/or backed up file space.  
Explanation: During a delete filespace operation, you specified a file space to  
which your node does not have permission to delete archived data and/or backed up  
data.  
System Action: Delete processing fails.  
User Response: See your system administrator.  
ANS1127E  
ANS1128S  
ANS1129S  
Your node does not have permission to delete archived files  
Explanation: Your node is not allowed by the server to delete archived files.  
System Action: TSM did not delete the archived files.  
User Response: See your system administrator.  
Invalid Management Class assigned to directories. Please see the error log.  
Explanation: An invalid management class was assigned to directories.  
System Action: Processing stopped.  
User Response: Have your service representative check the error log.  
No backup copy group in the management class used for directories. Please see  
the error log.  
Explanation: The management class used for directories does not have a backup  
copy group.  
System Action: Processing stopped.  
User Response: Have your service representative check the error log.  
Tivoli Storage Manager Messages  
1159  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1132E  
Access rule’ Access Rule already defined for node ’node’. Old rule must be  
deleted before new one can be defined.  
Explanation: You are trying to define authorization for the specified node, which  
already has authorization defined.  
System Action: TSM did not redefine authorization for the specified node.  
User Response: Update the authorization, or delete the old rule and define a new  
one, or use the current authorization.  
ANS1133W  
An expression might contain a wildcard not enclosed in quotes  
Explanation: TSM cannot process the command because a UNIX shell expands a  
wildcard expression, for example, asterisk (*) or question mark (?), that has no  
quotes.  
System Action: Command dependent.  
User Response: Enclose the wildcard expression in quotes and enter the command.  
ANS1136E  
ANS1137W  
ANS1138E  
ANS1139E  
Not file owner  
Explanation: The file cannot be backed up because the client is not the file owner.  
System Action: TSM skips the file.  
User Response: None.  
Invalid Index ’number’ skipped.  
Explanation: An incorrect number was entered for the Index.  
System Action: Processing stopped.  
User Response: Correct the Index entry and retry the operation.  
The ’command-name’ command must be followed by a subcommand  
Explanation: You entered an incomplete command-name.  
System Action: Processing stopped.  
User Response: Enter the correct syntax of the command and continue.  
Subcommand-name’ is an invalid subcommand for ’command-name’  
Explanation: You entered an incorrect subcommand-name for the specified  
command-name.  
System Action: Processing stopped.  
User Response: Enter the command with a correct subcommand.  
ANS1140E  
Invalid format for Set Access command.  
Explanation: None.  
System Action: Processing stopped.  
User Response: Enter the SET ACCESS command using the correct syntax.  
1160  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1141W  
ANS1143E  
Unknown command - command-name  
Explanation: You entered an incorrect command-name.  
System Action: None.  
User Response: Enter the correct command.  
The DIRSONLY and FILESONLY options are not valid together  
Explanation: The DIRSONLY and FILESONLY options cannot be used together.  
System Action: Processing stopped.  
User Response: Try again using either the DIRSONLY or the FILESONLY  
option.  
ANS1144W  
Password authentication not active on server  
Explanation: None.  
System Action: Processing stopped.  
User Response: Because password authentication is turned off on the server, you  
do not need to update the password.  
ANS1145E  
ANS1146E  
Maximum macro nesting level exceeded.  
Explanation: Too many levels of macro nesting are encountered.  
System Action: The macro is ignored and an error is returned.  
User Response: Reduce the level of macro nesting.  
Macro file ’file spec’ cannot be opened.  
Explanation: A macro command has been entered that specifies the macro file  
name shown. However, that file cannot be opened for reading.  
System Action: The macro is ignored and an error is returned.  
User Response: Enter the command with the proper macro name.  
ANS1148I  
ANS1149E  
ANS1159E  
Command-name’ command successfully completed  
Explanation: The specified command-name was successfully completed.  
System Action: TSM completed the command.  
User Response: Continue with normal operations.  
No domain available for incremental backup  
Explanation: An incremental backup was started, but no domain was selected.  
System Action: Processing stopped.  
User Response: Choose a domain and restart the incremental backup.  
The specified file is being used by another process  
Explanation: The specified file is being used by another process. You tried to read  
from or write to a file that is currently being used by another process.  
System Action: Processing stopped.  
Tivoli Storage Manager Messages  
1161  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Ensure that you specified the correct file or directory name,  
correct the permissions, or specify a new location.  
ANS1168E  
ERROR: could not create image object.  
Explanation: Creation of the image object failed for one of the following reasons:  
The image command was executed by a non-root user  
Image operations are not supported on the current platform  
The image plugin library was not found.  
User Response: Retry the operation after correcting the cause for failure.  
System Action: The requested logical volume function is not performed.  
ANS1169W  
ANS1170W  
There is no table of contents for image-name.  
Explanation: The image item for which a table of contents was requested is either  
a RAW logical volume or it was backed up without the -TOC option.  
System Action: No table of contents is displayed.  
User Response: Select another image object for TOC display.  
Invalid selection number entered. Try again.  
Explanation: You entered a number not shown in the list of images. It is either  
less than one or greater than the highest item number displayed.  
System Action: TSM waits for you to enter a valid selection.  
User Response: Enter a number from the list or ’Q’ to quit.  
ANS1177E  
ANS1188E  
Must specify a path for this operation.  
Explanation: A path must be specified for this operation to execute successfully.  
System Action: Processing stops.  
User Response: Specify a valid path and execute the command again.  
The selected filesystem is managed by HSM, and therefore is not a valid object  
for image operations  
Explanation: Due to the nature of HSM, image backup is not allowed on managed  
filesystems.  
System Action: The requested logical volume operation is not performed.  
User Response: None.  
ANS1201E  
Unable to build a directory path; a file exists with the same name as a  
directory.  
Explanation: TSM tried to create a directory path, but is unable to because a file  
exists that has the same name as a directory.  
System Action: Processing stopped.  
1162  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Remove the file that has the same name as the directory. Refer to  
the last restore/retrieve operation and check all directories along the path.  
ANS1220E  
ANS1221E  
Server out of resources  
Explanation: The server ran out of resources. A lack of storage or a condition  
does not allow any new activity.  
System Action: TSM canceled the current operation.  
User Response: Retry the operation at a later time. If the problem continues, see  
your system administrator to isolate what resource is unavailable.  
Transaction aborted  
Explanation: The current transaction between the server and the client stopped. A  
server, client, or communication failure cannot be recovered.  
System Action: TSM canceled the current operation.  
User Response: Retry the operation. If the problem continues, see your system  
administrator to isolate the problem.  
ANS1222E  
ANS1223E  
Disk space limit for this process reached  
Explanation: The disk space allocated for the client owner is full.  
System Action: Processing stopped.  
User Response: Free up disk space and retry the restore or retrieve operation.  
File is not compressed; System failure.  
Explanation: A file that was flagged as compressed was not compressed, and the  
system failed.  
System Action: Processing stopped.  
User Response: See your system administrator to report this problem. This error is  
a system failure.  
ANS1224E  
File compressed on a different client machine that has more memory  
Explanation: You are trying to restore a file that was backed up and compressed  
on another client workstation that had more memory than your client workstation.  
You cannot restore this file. When the file is restored, it is expanded and your  
workstation does not have enough memory.  
System Action: TSM canceled the operation.  
User Response: Obtain a machine with more memory and retry the operation.  
ANS1225E  
Insufficient memory for file compression/expansion  
Explanation: Not enough memory is available to do data compression or  
expansion. For a restore or retrieve, the file cannot be recalled from the server until  
more storage is made available. For a backup or archive, try running without  
compression if storage cannot be made available.  
System Action: Processing stopped.  
Tivoli Storage Manager Messages  
1163  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Free up extra storage for the operation to continue, or run the  
backup or archive process without compression enabled.  
ANS1226E  
Destination file or directory is write locked  
Explanation: The file or directory being restored or retrieved from the server  
cannot be written to because the destination is write locked. Another operation  
might have the file open and will not allow it to be updated.  
System Action: File skipped.  
User Response: Either determine which operation has the file write locked, or  
restore the file to another name or location.  
ANS1227E  
ANS1228E  
ANS1231E  
Processing stopped; Disk full condition  
Explanation: No more files can be restored or retrieved because the destination  
disk is full.  
System Action: Processing stopped.  
User Response: Free up disk space, or restore or retrieve the file to another disk.  
Sending of object ’object-nameobject-nameobject-name’ failed  
Explanation: The specified file (object-name) cannot be sent to the server.  
System Action: File skipped.  
User Response: Retry the operation. If the problem continues, see your system  
administrator to isolate the problem through use of the server console.  
No file handles available  
Explanation: All file handles for your system are currently in use. No more are  
available.  
System Action: Processing stopped.  
User Response: Either free some file handles by ending other processes, or modify  
your system setup to allow for more files to be open at the same time.  
ANS1232E  
ANS1233E  
File exists  
Explanation: The file being restored or retrieved exists.  
System Action: File is replaced or skipped depending on client options.  
User Response: None.  
Invalid file handle passed; System Error.  
Explanation: An internal system error occurred. A file operation failed because an  
invalid file handle was passed.  
System Action: Processing stopped.  
User Response: Report the problem to your system administrator, and then retry  
the operation.  
1164  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1234E  
ANS1235E  
ANS1236E  
ANS1241E  
Protocol violation  
Explanation: A communications protocol error occurred. The communication  
subsystem is not properly defined or is itself in error.  
System Action: TSM ended the current operation.  
User Response: Verify that the communication processes are operating properly,  
and then retry the operation.  
Unknown system error  
Explanation: An unknown error occurred. This might be a low-level system or  
communication error that TSM cannot handle or recover from.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, determine where  
the problem exists. See your system administrator for further help.  
Unexpected error  
Explanation: An unexpected error occurred. This might be a low-level system or  
communication error that TSM cannot handle or recover from.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, determine where  
the problem exists. See your system administrator for further help.  
File is in use; Write permission denied.  
Explanation: The current file cannot be opened to write to because it is currently  
being run by another operation.  
System Action: File skipped.  
User Response: Stop the operation that is running the file and retry the operation,  
or restore or retrieve the file to a different name or directory.  
ANS1242E  
ANS1243E  
Too many symbolic links were detected while resolving name  
Explanation: While trying to resolve the file name, too many symbolic links were  
found.  
System Action: File skipped.  
User Response: Ensure that you do not have a looping symbolic link for the file.  
File name too long  
Explanation: The file name specified is too long to be handled by TSM.  
System Action: File is skipped.  
User Response: See the appropriate Using the Backup-Archive Client book for the  
particular operating system, for the file names that are handled by TSM.  
Tivoli Storage Manager Messages  
1165  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1244E  
ANS1245E  
ANS1246E  
File system is locked by system  
Explanation: File system cannot be accessed because it is locked by the system.  
System Action: TSM cannot complete the operation.  
User Response: See your system administrator.  
Format unknown  
Explanation: TSM tried to restore or retrieve a file, but it had an unknown format.  
System Action: File skipped.  
User Response: See your system administrator.  
A command-line argument exceeded the maximum length (maximum length) for  
a single token.  
Explanation: Command-line arguments may not exceed maximum length  
characters.  
System Action: The command is not processed.  
User Response: Correct the command and retry the operation.  
ANS1247I  
ANS1248E  
Waiting for files from the server...  
Explanation: Restore request has been sent to the server. The wait time depends  
on how many files you are restoring.  
System Action: TSM waits for files to restore from the server.  
User Response: None.  
An active restore for the same source file specification exists. Unable to  
continue with this request.  
Explanation: Currently, there is an active restore for the same source file  
specification. Another restore of the same source file specification cannot be started.  
System Action: The requested restore fails.  
User Response: Start another restore with a different source file specification.  
ANS1249W  
ANS1251E  
Server cannot restart the last restore request. Do you want to restore without  
restart or abort the request?  
Explanation: The restart restore token has expired. The server cannot restart the  
restore from where it last ended.  
System Action: Processing stopped; waiting for user intervention.  
User Response: Retry the request without restart or abort the request.  
File system/drive not ready  
Explanation: The file system/drive was not ready for access.  
System Action: Processing stopped.  
User Response: Ensure that the drive is available to TSM, and then retry the  
operation.  
1166  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1252E  
File system/drive is bad. A directory exists that is missing either a ’.’ or ’..’  
entry. Have your service representative check the error log.  
Explanation: The drive was not available for access. A directory exists that does  
not have either a '.' or '..' entry.  
System Action: Processing stopped.  
User Response: Ensure that the drive is operational, and then retry the operation.  
If unsuccessful, have your service representative check the error log.  
ANS1253E  
File input/output error  
Explanation: An error was found while reading from or writing to the file.  
System Action: File or file system is skipped.  
User Response: Check your system to ensure that it is operating properly. For  
OS/2, run CHKDSK /F for the failing drive which can be found in dsmerror.log.  
ANS1254E  
ANS1255E  
File write error  
Explanation: An error was found while writing to the file.  
System Action: File skipped.  
User Response: Check your system to ensure that it is operating properly.  
File exceeds system/user file limits  
Explanation: A file being restored or retrieved exceeds system set limits for this  
user.  
System Action: File skipped.  
User Response: Ensure that the system limits are set properly.  
ANS1260E  
ANS1261W  
File is being recalled or has been recalled.  
Explanation: The file is being recalled by another process or has been recalled.  
System Action: File skipped.  
User Response: None  
The archive description you specified is the empty string. TSM will use the  
default description (Archive Date: current date).  
Explanation: The description option on the archive command may not specify a  
null string.  
System Action: Processing continues, and the description option is ignored.  
User Response: None. Specify at least one character in the description  
Tivoli Storage Manager Messages  
1167  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1262E  
The active policy set does not contain any backup copy groups. If you continue  
with the incremental backup, any currently backed up files are deactivated on  
the server and assigned the Backup Grace Period.  
Explanation: You tried to back up the files using a policy set that contains no  
backup management information (the copy group). None of the management classes  
within the active policy set contain any backup copy groups.  
System Action: If you continue with the incremental backup, the workstation file  
is not backed up, and any backup versions currently residing in data storage are  
assigned to the backup retention grace period defined for the policy domain. TSM  
prompts you for a yes or no response.  
User Response: Reply yes to accept the Backup Grace Retention Period or no to  
cancel the operation. If you cancel the operation, you can retry the incremental  
backup by creating a management class that has a backup copy group and bind the  
file to that management class in your include-exclude list. If unsuccessful, see your  
system administrator for more information.  
ANS1263E  
The active policy set does not contain any backup copy groups. Unable to  
continue with selective backup.  
Explanation: You tried to do a selective backup and have specified a policy set  
that does not contain a backup management information (the copy group).  
System Action: TSM did not backup the file.  
User Response: Create a management class that has a backup copy group, bind  
the file to that management class in your include-exclude list, and retry the  
operation. If unsuccessful, see your system administrator for more information.  
ANS1264E  
The active policy set does not contain any archive copy groups. Unable to  
continue with archive.  
Explanation: You tried to archive a file or group of files and have specified a  
policy set that does not contain an archive management information (the copy  
group).  
System Action: TSM did not archive the file.  
User Response: Create a management class that has an archive copy group, assign  
the file to the management class, either through your include-exclude list or with the  
ARCHMC option, and retry the operation. If unsuccessful, see your system  
administrator for more information.  
ANS1268E  
This file has been migrated.  
Explanation: File has been migrated. If files that are hard linked together are  
migrated then files subsequent to the first one encountered get this.  
System Action: File is skipped.  
User Response: None.  
1168  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1269I  
ANS1301E  
File is implicitly excluded.  
Explanation: You tried to back up or migrate a file that is implicitly excluded.  
System Action: TSM will not back up or migrate an implicitly excluded file.  
User Response: None.  
Server detected system error  
Explanation: The server detected a system error and notified the clients.  
System Action: Processing stopped.  
User Response: See your system administrator for further information on server  
activity.  
ANS1302E  
ANS1303E  
No objects on server match query  
Explanation: No objects on the server match the query operation being performed.  
System Action: Processing stopped.  
User Response: Ensure the names are properly entered.  
Client ended transaction  
Explanation: The client system ended the operation with the server and ended the  
current transaction.  
System Action: Processing stopped.  
User Response: Restart the session.  
ANS1304W  
ANS1305E  
Active object not found  
Explanation: TSM did not find an active object flagged for expiration on the  
server. The object is marked as expired by another TSM operation.  
System Action: None.  
User Response: None.  
No data on server  
Explanation: TSM tried to do a restore or retrieve on an object that has no data  
associated with it.  
System Action: TSM ended the current operation.  
User Response: See your system administrator to verify the problem. If the  
problem continues, see your system administrator.  
ANS1306E  
Bad verifier  
Explanation: You entered an incorrect password (verifier).  
System Action: Processing stopped.  
User Response: Retry the session with the correct password.  
Tivoli Storage Manager Messages  
1169  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1307E  
ANS1308E  
ANS1309W  
Node in use  
Explanation: The node you are running on is in use by another operation on the  
server. This might be from another client or from some activity on the server.  
System Action: Processing stopped.  
User Response: Retry the operation, or see your system administrator to see what  
other operations are running for your node.  
Expiration date must be greater than today’s date  
Explanation: Archive expiration date is too low, the date must be greater than  
today’s date.  
System Action: TSM canceled the current operation.  
User Response: Retry archiving the file with an expiration date that is higher than  
today’s date.  
Requested data is offline  
Explanation: For the restore or retrieve operation, one or more of the requested  
files must be recalled from offline storage media (generally tape). The wait time  
depends on your site’s offline storage management policies.  
System Action: TSM waits for offline storage media to become available and then  
continues.  
User Response: None.  
ANS1310E  
ANS1311E  
Object too large for server limits  
Explanation: The object is too large. The configuration of the server does not  
have any data storage space that accepts the object.  
System Action: File skipped.  
User Response: See your system administrator to determine the maximum file  
(object) size for which your site’s server is configured.  
Server out of data storage space  
Explanation: The server does not have any space available to store the object.  
System Action: TSM ended the current operation.  
User Response: You can take any of the following actions:  
Request the system administrator to add space to the storage pool.  
Set COMPRESSALWAYS=NO and COMPRESSIon=YES in the options file  
(DSM.OPT). If the file grows during compression, then TSM will resend it  
uncompressed.  
Turn off disk caching in the disk storage pool, and issue MOVE DATA  
commands to each disk pool volume to clear out the cached bitfiles.  
1170  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1312E  
ANS1313E  
Server media mount not possible  
Explanation: Server media mount not possible. The server timed out waiting for a  
mount of an offline volume.  
System Action: File skipped.  
User Response: Retry later when server volumes can be mounted.  
Size estimate exceeded  
Explanation: The total amount of data for a backup or archive operation exceeds  
the estimated size originally sent to the server for allocating data storage space. This  
happens when many files are growing by large amounts while the backup or archive  
operation is in session.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, check what other  
processes are running on the client machine that are generating large amounts of  
data. Disable those operations while the backup or archive operation is taking place.  
ANS1314E  
File data currently unavailable on server  
Explanation: The file data is currently unavailable on the server. A retrieve or  
restore operation was attempted. Possible causes are:  
Data was corrupted at the server  
Server found a read error  
File is temporarily involved in a reclaim operation at the server  
Server requested a tape volume that was marked unavailable.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your system  
administrator to determine the problem from the server console or the activity log.  
Check whether any requests were made for a tape volume that was unavailable. A  
tape volume may be marked unavailable if prior read errors were encountered or the  
volume is checked out of the tape library.  
ANS1315E  
ANS1316E  
Unexpected Retry request  
Explanation: Unexpected Retry request. The server found an error while writing  
data to the server’s data storage.  
System Action: Client retries the operation.  
User Response: None.  
The server does not have enough recovery log space to continue the current  
operation  
Explanation: The server ran out of recovery log space.  
System Action: TSM ended the current operation.  
User Response: This error is a temporary problem. Retry later or see your system  
administrator.  
Tivoli Storage Manager Messages  
1171  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1317E  
ANS1318E  
ANS1320E  
The server does not have enough database space to continue the current  
operation  
Explanation: The server ran out of database space.  
System Action: TSM ended the current operation.  
User Response: See your system administrator.  
The server does not have enough memory to continue the current operation.  
Explanation: The server ran out of memory.  
System Action: TSM ended the current operation.  
User Response: This is a temporary problem. Retry later or see your system  
administrator.  
The specified file space does not exist on the server. The file space might have  
been deleted by another client or an administrator.  
Explanation: The specified file space does not exist on the server. Your system  
administrator deleted the file space or another client using your client’s node name  
deleted it.  
System Action: TSM canceled the current operation.  
User Response: Check the file space name to see if it is correct, and retry the  
operation.  
ANS1321S  
Open Registration failed because the specified node name is defined in the  
server  
Explanation: Open registration failed because a node is defined in the server with  
the same name.  
System Action: TSM canceled the current operation.  
User Response: Retry with another node name.  
ANS1322S  
ANS1323S  
Open Registration failed because no default domain exists  
Explanation: Open registration failed because a default policy domain does not  
exist for you to place your node.  
System Action: TSM canceled the current operation.  
User Response: See your system administrator.  
Open Registration failed because an invalid node name was specified  
Explanation: Open registration failed because the specified node name contains  
invalid characters.  
System Action: TSM canceled the current operation.  
User Response: Retry with another node name that does not have any invalid  
characters.  
1172  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1326S  
ANS1329S  
ANS1330S  
Unexpected Wait For Space from the server  
Explanation: The client received an unexpected Wait For Space message from the  
server.  
System Action: TSM ended the current operation.  
User Response: See your system administrator.  
Server out of data storage space  
Explanation: The server does not have space available to store the object.  
System Action: TSM ended the current operation.  
User Response: Report to your system administrator that a storage pool on the  
server is full.  
This node currently has a pending restartable restore session. The requested  
operation cannot complete until this session either completes or is canceled.  
Explanation: This operation can not be completed because a restartable restore  
session is pending. The operation is not allowed because the restartable session and  
the current operation affect the same file space.  
System Action: TSM ended the current operation.  
User Response: Issue a query restore to see the conflict. Issue the cancel restore  
command to delete any unneeded restartable restore sessions.  
ANS1331E  
Only a TSM authorized user can perform this Action.  
Explanation: User must be a TSM authorized user to perform this action. User is  
not password authorized and this action requires authorization.  
System Action: Processing stopped.  
User Response: User must be root user, or user must be the owner of the  
executable and the set effective user id bit is set to ’on’ (’s’ bit).  
ANS1334E  
ANS1335E  
Restoring a volume mount point to a non-empty directory.  
Explanation: You are trying to restore a volume mount point to a non-empty  
directory which is not allowed. Volume mount point is not restored.  
System Action: Processing continues.  
User Response: None.  
Importing RSM database files failed. No changes will be in effect.  
Explanation: An error occurred while importing the RSM database files. The  
database will not be updated.  
System Action: Processing stopped.  
User Response: Ask your system administrator to check the error log.  
Tivoli Storage Manager Messages  
1173  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1336I  
ANS1337I  
ANS1338I  
ANS1339E  
RSM service must be restarted for changes to become effective.  
Explanation: RSM database files have been restored from the server and  
imported. The RSM service must be restarted for the updates to become effective.  
System Action: Processing continues.  
User Response: None.  
Restarting the RSM service...  
Explanation: RSM database files have been restored from the server and  
imported. TSM is about to stop then restart the RSM service.  
System Action: Processing continues.  
User Response: None.  
Restart of the RSM service is completed.  
Explanation: RSM database files have been restored from the server and  
imported. TSM has restarted the RSM service on the user’s behalf.  
System Action: Processing continues.  
User Response: None.  
Restart of the RSM service failed. Restart the RSM service manually.  
Explanation: RSM database files have been restored from the TSM server and  
imported. TSM has tried to restart the RSM service on the user’s behalf but has run  
into a problem.  
System Action: Processing stopped.  
User Response: Restart the RSM service manually.  
ANS1340E  
Exporting RSM database files failed. No files will be backed up.  
Explanation: An error occurred while exporting the RSM database files. The  
database will not be backed up.  
System Action: Processing stopped.  
User Response: Ask your system administrator to check the error log.  
ANS1425E  
ANS1426E  
Administrator authority is required to run TSM Backup.  
Explanation: The user attempting to run the backup client is not an administrator.  
System Action: The client terminates.  
User Response: Run the client from an administrative logon.  
An error occurred creating the Backup Registry Directory structure  
Explanation: An error occurred while creating the directory structure to the  
save/replace registry key.  
System Action: Registry function fails.  
User Response: See your system administrator.  
1174  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1427I  
ANS1428E  
ANS1429I  
ANS1430I  
Registry Backup function completed successfully.  
Explanation: Registry backup was successful.  
System Action: None.  
User Response: Continue with normal operations.  
Registry Backup function failed.  
Explanation: An error occurred while backing up the registry.  
System Action: Registry backup function fails.  
User Response: See your system administrator.  
Registry Restore function completed successfully.  
Explanation: Registry Restore was successful.  
System Action: None.  
User Response: Continue with normal operations.  
The machine must be rebooted for the changes to take effect  
Explanation: The machine must be started for the restored registry changes to take  
effect.  
System Action: None  
User Response: Reboot the machine  
ANS1431E  
ANS1432E  
ANS1433E  
ANS1434E  
Registry Restore Function Failed.  
Explanation: An error occurred while restoring the registry key(s) from the server.  
System Action: Registry restore function fails.  
User Response: See your system administrator.  
Keyword Expected after keyword ’keyword’.  
Explanation: A registry command was incorrectly entered.  
System Action: Registry function is not invoked.  
User Response: Refer to the command reference for this command.  
Extraneous argument ’input’ after keyword ’keyword’  
Explanation: A registry command was incorrectly entered.  
System Action: Registry function not invoked.  
User Response: Refer to the command reference for this command.  
Invalid argument ’input’ after keyword ’keyword’  
Explanation: A registry command was incorrectly entered.  
System Action: Registry function not invoked.  
User Response: Refer to the command reference for this command.  
Tivoli Storage Manager Messages  
1175  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1435E  
ANS1436E  
An Error Occurred saving the Key.  
Explanation: The active registry key cannot be saved.  
System Action: Registry backup operation terminates.  
User Response: See your system administrator.  
An Error Occurred replacing the Key.  
Explanation: The backed up registry key is restored from the server but cannot be  
made active into the registry.  
System Action: Current Registry key remains active.  
User Response: See your system administrator.  
ANS1437I  
ANS1438E  
ANS1439I  
ANS1440E  
ANS1441E  
ANS1442E  
Event Log Backup function completed successfully.  
Explanation: Event Log backup was successful.  
System Action: None.  
User Response: Continue with normal operations.  
Event Log Backup function failed.  
Explanation: An error occurred while backing up the event logs.  
System Action: Event log backup function fails.  
User Response: See your system administrator.  
Event Log Restore function completed successfully.  
Explanation: Event Log Restore was successful.  
System Action: None.  
User Response: Continue with normal operations.  
Event Log Restore Function Failed.  
Explanation: An error occurred while restoring the event log(s) from the server.  
System Action: Event Log Restore function fails.  
User Response: See your system administrator.  
Keyword Expected after keyword ’keyword’.  
Explanation: A event log command was incorrectly entered.  
System Action: Event Log function is not invoked.  
User Response: Refer to the command reference for this command.  
Extraneous argument ’input’ after keyword ’keyword’  
Explanation: A event log command was incorrectly entered.  
System Action: Event Log function not invoked.  
User Response: Refer to the command reference for this command.  
1176  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1443E  
ANS1444E  
Invalid argument ’input’ after keyword ’keyword’  
Explanation: A event log command was incorrectly entered.  
System Action: Event Log function not invoked.  
User Response: Refer to the command reference for this command.  
An error occurred creating the Backup Registry Directory structure  
Explanation: An error occurred while creating the directory structure to the  
save/replace registry key.  
System Action: Registry function fails.  
User Response: See your system administrator.  
ANS1447I  
ANS1448E  
Current user does not need to back up the default profile.  
Explanation: You are currently using the default profile, and there is no need to  
back it up.  
System Action: None.  
User Response: None.  
An error occurred accessing NTFS security information  
Explanation: An error occurred while attempting to access NTFS security  
information.  
System Action: Object will not be processed.  
User Response: See your system administrator or bypass by using SkipNTSecurity  
option.  
ANS1449E  
A required NT privilege is not held  
Explanation: The user account running TSM does not possess a required NT user  
right/privilege for performing the current operation.  
System Action: Object will not be processed.  
User Response: See your system administrator.  
ANS1483I  
ANS1484I  
Schedule log pruning started.  
Explanation: The schedule log pruning function has begun.  
System Action: The schedule log is pruned.  
User Response: None.  
Schedule log pruning finished successfully.  
Explanation: The schedule log pruning function completed with no errors.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
1177  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1485E  
ANS1489E  
ANS1490W  
Schedule log pruning failed.  
Explanation: The schedule log pruning function failed.  
System Action: The schedule log pruning function stops.  
User Response: Retry the command with the tracing turned on to help determine  
why the pruning function failed.  
Unable to open the file list input file: ’file-name’  
Explanation: The file named on the -LISTFILE option could not be opened.  
System Action: TSM Command not executed.  
User Response: Make sure the file name is given correctly and can be accessed  
for reading.  
File specification ’file-spec’ ignored. A file list has already been specified.  
Explanation: A non-option argument (file specification) was encountered after the  
-FILELIST has been processed.  
System Action: The argument is ignored.  
User Response: You may have either a -FILELIST or explicit file specifications  
on this command, but not both.  
ANS1491E  
ANS1492W  
Only one -FILELIST option allowed.  
Explanation: The -FILELIST option may only be specified once per command  
System Action: The command is not executed.  
User Response: Enter only one -FILELIST option on the command.  
File specification ’file-spec’ ignored, the FILELIST option is being processed.  
Explanation: The -FILELIST option is being processed and  
previously-encountered explicit file specifications were found.  
System Action: The explicit arguments are ignored.  
User Response: You may have either a -FILELIST or explicit file specifications  
on this command, but not both.  
ANS1511W  
ANS1512E  
Invalid Restore session number entered. Try again.  
Scheduled event ’event’ failed. Return code = value.  
Explanation: The scheduled event did not complete successfully.  
System Action: Scheduled event failed.  
User Response: Ensure that your environment is set up correctly. If the problem  
continues, see your system administrator to correct the problem.  
ANS1802E  
Incremental backup of ’file-name’ finished with number failure  
Explanation: The incremental backup of the specified file-name completed with  
the specified number of failures.  
1178  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing continues.  
User Response: Check the reasons for the failures.  
ANS1803E  
ANS1804E  
Archive processing of ’file-space name’ finished with failures.  
Explanation: The archive of the specified file-space name completed with failures.  
System Action: Processing continues.  
User Response: Check the reasons for the failures.  
Selective Backup processing of ’file-space name’ finished with failures.  
Explanation: The selective backup of the specified file-space name completed  
with failures.  
System Action: Processing continues.  
User Response: Check the reasons for the failures.  
ANS1805E  
ANS1806W  
Unable to restore symbolic link ’file-name’.  
Explanation: The client operating system is not able to create a symbolic link  
because the link points to a filename that is not given.  
System Action: Processing continues.  
User Response: Try the restore on a different operating system.  
Size exceeded the maximum file size limit on your system for ’filespace  
namepath-namefile-name’ of ’file-size’.  
Explanation: You tried to restore or retrieve a file that has exceeded the maximum  
file size limitation on your system.  
System Action: TSM cannot restore or retrieve the file.  
User Response: Restore or retrieve this file on a system that supports the file size.  
See your system administrator.  
ANS1807E  
Unable to recall file from server due to error from recall daemon.  
Explanation: Unable to recall file. The recall daemon reported an error while  
trying to recall a file. Look in the recall daemon’s error log for more information.  
This can happen if the server is down, the connection is broken, or the file is  
missing on the server. It is also possible that the migration server in the system  
option file has been changed to a different server. The recall daemon does not check  
the system option file for changes once it has started.  
System Action: File skipped.  
User Response: See if the server is up, and retry. If the problem still exists, look  
in the error log. Also have the workstation administrator run dsmreconcile against  
the file system and see if the file shows up in the .SpaceMan/orphan.stubs file. If  
system option file has been changed, stop all recall daemons and restart the master  
recall daemon to pick up the changes.  
Tivoli Storage Manager Messages  
1179  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1808E  
Invalid option/value for an interactive session: ’session’  
Explanation: You entered an option that cannot be used during an interactive  
session.  
System Action: Processing stopped.  
User Response: Quit out of the interactive session and try the option/value on the  
command line as you start the interactive session.  
ANS1809E  
ANS1810E  
ANS1811S  
Session is lost; initializing session reopen procedure.  
Explanation: The session with the server has been lost.  
System Action: The system will attempt to reestablish session with TSM.  
User Response: None.  
TSM session has been reestablished.  
Explanation: The session with the server has been reestablished.  
System Action: Processing will now continue.  
User Response: None.  
TSM session could not be reestablished.  
Explanation: The session with the server has been lost. Attempts to reestablish the  
session were unsuccessful. Possible causes include, but are not limited to the  
following:  
The server has been halted.  
The network connection to the server is down.  
The communication program that TSM is interacting with has encountered some  
problem.  
System Action: Processing is stopped.  
User Response: Check network connection to the server. Insure that the TSM  
server is running. Insure that the communication program underlying TSM is  
working properly.  
ANS1812E  
ANS1813E  
Out of storage  
Explanation: The system ran out of storage resources.  
System Action: Processing stopped.  
User Response: Free up extra storage to continue, and retry the operation.  
Invalid scheduled command - ’command-name command-name command-name  
command-name’  
Explanation: You entered a command for schedule that is incorrect.  
System Action: Processing stopped.  
User Response: Enter the command correctly and retry the operation.  
1180  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1814E  
Unable to start scheduled event ’event’  
Explanation: Scheduled event was no longer valid on the server. Either the  
window has elapsed or the schedule has been deleted.  
System Action: The client scheduler queries the server to obtain the next  
scheduled event.  
User Response: If the problem continues, see your system administrator to correct  
the problem on the server.  
ANS1815E  
Either the window has elapsed or the schedule has been deleted  
Explanation: Scheduled event was no longer valid on the server.  
System Action: The client scheduler queries the server to obtain the next  
scheduled event.  
User Response: If the problem continues, see your system administrator to correct  
the problem on the server.  
ANS1816E  
ANS1817E  
Invalid scheduling mode  
Explanation: The mode entered for the scheduled event was not correct.  
System Action: Event does not occur.  
User Response: Enter the correct scheduling mode and retry the operation.  
Schedule function can only be run by a TSM authorized user.  
Explanation: An attempt to use the schedule function failed because of improper  
authority.  
System Action: Processing stopped.  
User Response: See the TSM authorized user for schedule function information.  
ANS1818E  
ANS1819E  
Schedule function not allowed in loop mode.  
Explanation: The operation cannot be scheduled during a loop mode.  
System Action: Event does not occur.  
User Response: Enter the command again without the loop.  
Server cannot register address  
Explanation: An address for a server was entered that cannot be recorded.  
System Action: Processing stopped.  
User Response: Ensure that you have the server specified correctly, and retry the  
operation.  
ANS1820E  
Command line options must be preceded by a ’-’  
Explanation: An option was specified without a '–' delimiter.  
System Action: Processing stopped.  
User Response: Enter the command again with a dash preceding each option.  
Tivoli Storage Manager Messages  
1181  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1821E  
Unable to start POSTSCHEDULECMD/ PRESCHEDULECMD ’command’  
Explanation: The requested action required a new process to be created. Either an  
option or a schedule “action” that requested an operating system command to be  
executed was entered.  
System Action: Request is ignored.  
User Response: Remove the request from the options file or the schedule defined  
on the server.  
ANS1868E  
ANS1869E  
Invalid Management Class ’management-class’ found in the Include Exclude  
file.  
Explanation: The management-class included in the Include Exclude file does not  
exist. See TSM error log for more information.  
System Action: Processing continued using the default Management Class.  
User Response: Correct the Include Exclude file entry.  
The NDS object requires its parent, or container, to be present before this  
object can be restored. Try first restoring the parent of this object.  
Explanation: SMS requires the parent of the object (container) to be present  
before the child or object can be created.  
System Action: Processing stops.  
User Response: Retry restoring, but at least one level up. For instance, restore  
'dir\.o=ibm\*' instead of 'dir\ou=gpl.o=ibm\*'.  
ANS1872E  
ANS1874E  
ANS1875E  
Unable to connect to NetWare target service ’server-name’. Make sure the TSA  
NLM is loaded on the specified machine.  
Explanation: TSM interacts with the Target Service Agent (TSA) and the  
connection cannot be made to the Netware server-name.  
System Action: Processing stopped.  
User Response: Ensure that the TSA is loaded and retry the TSM command.  
Login denied to NetWare Target Service Agent ’server-name’.  
Explanation: The connection to the Target Service Agent (TSA) requires a  
NetWare user name and a password. The password you entered at the prompt may  
be incorrect.  
System Action: Processing stopped.  
User Response: Retry the TSM command, supplying the correct LAN password.  
Unable to connect to target service. Out of memory.  
Explanation: Not enough memory to connect to the Target Service Agent (TSA).  
System Action: Processing stopped.  
User Response: Either add memory to the server or free memory by unloading  
some programs, or by restarting the server.  
1182  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1876E  
ANS1877E  
Unable to connect to target service. NetWare SMS return code = value.  
Explanation: Unexpected return code value.  
System Action: Processing stopped.  
User Response: See your service representative.  
The name is too long for TSM to process.  
Explanation: The name was being parsed. The parsing routine detected that TSM  
cannot process it.  
System Action: TSM canceled the current operation.  
User Response: See your service representative if this error persists.  
ANS1879E  
ANS1880E  
NetWare NDS error on restore processing: **object ’nds_objectnds_object’  
**TSA error ’tsa_error’, tsa_error_text  
Explanation: TSM received an unexpected error from the Novell TSA interface.  
System Action: Object skipped.  
User Response: Report the program error to your service representative.  
TSA Connect error, NWSMConnectToTargetService ’TSA_Target_Service’  
password file ’password_file’. Userid = ’NetWare_userid’ failed with cc =  
TSA_ccode  
Explanation: TSM received an unexpected error from the Novell TSA interface  
while processing the userid and password from NWPWFILE.  
System Action: If the failure is a 'Login Denied' the user will be prompted for a  
Novell NetWare Userid and Password, and a password file will be created.  
User Response: The cc is returned from the TSA which belongs to Novell  
NetWare. If you get cc = FFFDFFD7 'Login Denied', please check the following:  
The user-id has been disabled.  
The user-id/password is invalid or expired.  
The user-id has inadequate security access.  
The user-id has insufficent rights to files and directorys.  
The user-id specified has a login restriction based on time-0f-day.  
The user-id specified has a Network address restriction.  
The user-id specified has a login restriction based on number of concurrent  
connections.  
NetWare is not allowing logins (DISABLE LOGIN was issued at the console).  
If you are unable to determine what is wrong, report the problem to your service  
representative.  
Tivoli Storage Manager Messages  
1183  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1881E  
TSM is unable to use NWPWFILE ’password_file’ to connect TSA target  
service ’TSA_Target_Service’, the file is corrupted.  
Explanation: TSM could not use the NWPWFILE to connect to Novell TSA  
interface. The file was corrupted.  
System Action: User will be prompted for Novell NetWare Userid and Password,  
and password file will be created.  
User Response: The file can be corrupted via another application or hardware  
failures. If problem is persistent contact your service representative. A copy of the  
corrupted password file will be needed. This corrupted file must be preserved before  
you enter a new userid and password, because TSM will overwrite the corrupted file  
with correct information.  
ANS1882W  
Unable to open NWPWFILE ’password_file’ for TSA target service  
TSA_Target_Service’.  
Explanation: TSM could not open the NWPWFILE to connect to Novell TSA  
interface.  
System Action: User will be prompted for Novell NetWare Userid and Password,  
and password file will be created.  
User Response: This can be normal if you are using NWPWFILE for the first  
time and it does not exist. If the file does exist it may be locked and TSM can not  
read it, determine why the file is locked. If the problem persists, report it to your  
service representative.  
ANS1896I  
ANS1897I  
ANS1898I  
***** Restored number objects *****  
Explanation: Indicates the number of objects TSM has restored. During a restore  
session, the running total is periodically printed to the screen of a command line  
client.  
System Action: Continue with restore.  
User Response: None.  
***** Retrieved number objects *****  
Explanation: Indicates the number of objects TSM has retrieved. During a retrieve  
session, the running total is periodically printed to the screen of a command line  
client.  
System Action: Continue with retrieve.  
User Response: None.  
***** Processed count files *****  
Explanation: TSM has processed the specified number of files.  
System Action: Processing continues.  
User Response: None.  
1184  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1899I  
***** Examined count files *****  
Explanation: TSM has examined the specified number of files.  
System Action: Processing continues.  
User Response: None.  
ANS1900W  
The archive description you specified is not unique. Please enter a unique  
archive description.  
Explanation: Descriptions for archive files must be unique per archive operation.  
System Action: Processing stopped.  
User Response: Enter an archive description that is unique.  
ANS1901W  
The server needs to do a one-time conversion of your archive data before you  
can continue. This operation may take a long time, and cannot be canceled  
once it has started. Are you willing to wait for the conversion to complete?  
Explanation: The server must do a conversion of the archive data before  
continuing. The conversion could take a long time, and cannot be canceled once it  
is started.  
System Action: Processing stopped; waiting for user intervention.  
User Response: Answer 'Yes' to start the archive data conversion. If you answer  
'No', the current operation will be canceled.  
ANS1902I  
ANS1903I  
ANS1905E  
ANS1906I  
The archive conversion completed successfully  
Explanation: The archive conversion completed successfully.  
System Action: Processing is completed.  
User Response: None  
Waiting for archive conversion to complete...  
Explanation: The program is waiting for the archive conversion to complete.  
System Action: Processing continues.  
User Response: None  
NetWare SMS error processing ’filespace-namepath-namefile-name’: error-text  
Explanation: TSM received an unexpected error from the Novell SMS interface.  
System Action: Object skipped.  
User Response: Report the program error to your service representative.  
Destination must be specified for this operation when using FROMNODE.  
Explanation: The user must specify a destination with a Restore/Retrieve  
command when using FROMNODE processing.  
System Action: Processing stopped.  
User Response: Retry the Restore/Retrieve command with a destination specified.  
Tivoli Storage Manager Messages  
1185  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1912E  
ANS1913E  
ANS1914E  
An invalid registry hive was specified.  
Explanation: The specified registry hive is invalid.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An invalid registry subkey was specified.  
Explanation: The specified registry subkey is invalid.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
The specified subkey isn’t valid for the specified hive.  
Explanation: The specified registry subkey is invalid for the specified registry  
hive.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
ANS1915E  
ANS1916E  
ANS1917E  
ANS1918E  
Too many arguments specified for the BACKUP REGISTRY command.  
Explanation: Too many arguments were specified for the BACKUP REGISTRY  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too many arguments specified for the RESTORE REGISTRY command.  
Explanation: Too many arguments were specified for the RESTORE REGISTRY  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too few arguments specified for the BACKUP REGISTRY command.  
Explanation: Too few arguments were specified for the BACKUP REGISTRY  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too few arguments specified for the RESTORE REGISTRY command.  
Explanation: Too few arguments were specified for the RESTORE REGISTRY  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
1186  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1919E  
ANS1920E  
The specified eventlog is not valid.  
Explanation: The specified eventlog is not valid.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too many arguments specified for the BACKUP EVENTLOG command.  
Explanation: Too many arguments were specified for the BACKUP EVENTLOG  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
ANS1921E  
ANS1922E  
ANS1923E  
Too many arguments specified for the RESTORE EVENTLOG command.  
Explanation: Too many arguments were specified for the RESTORE EVENTLOG  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too few arguments specified for the BACKUP EVENTLOG command.  
Explanation: Too few arguments were specified for the BACKUP EVENTLOG  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too few arguments specified for the RESTORE EVENTLOG command.  
Explanation: Too few arguments were specified for the RESTORE EVENTLOG  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
ANS1924E  
ANS1925E  
ANS1926E  
The specified system object is not valid.  
Explanation: The specified system object is not valid.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
The specified system object type is not valid.  
Explanation: The specified system object type is not valid.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
The specified system object type is only valid on Windows NT.  
Explanation: The specified system object type is only valid on Windows NT.  
System Action: Processing stopped.  
Tivoli Storage Manager Messages  
1187  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Correct the command and retry the operation.  
ANS1927E  
ANS1928E  
ANS1929E  
ANS1930E  
ANS1931E  
ANS1932E  
ANS1935E  
The specified function is not implemented.  
Explanation: The specified function is not implemented.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error occurred creating the registry staging directory.  
Explanation: An error occurred creating the registry staging directory.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error saving one or more registry keys.  
Explanation: An error occurred saving one or more registry keys.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error occurred creating the eventlog staging directory.  
Explanation: An error occurred creating the eventlog staging directory.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error saving one or more eventlogs.  
Explanation: An error occurred saving one or more eventlogs.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error replacing one or more registry keys.  
Explanation: An error occurred replacing one or more registry keys.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Too many arguments specified for the BACKUP NTDS command.  
Explanation: Too many arguments were specified for the BACKUP NTDS  
command.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
ANS1936E  
Not enough arguments specified for the BACKUP NTDS command.  
Explanation: Not enough arguments were specified for the BACKUP NTDS  
command.  
1188  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
ANS1937E  
No NTDS server name specified for the BACKUP NTDS command.  
Explanation: No NTDS server name was specified for the BACKUP NTDS  
command.  
System Action: Processing stopped.  
User Response: Specify NTDS server name at the command and retry the  
operation.  
ANS1938E  
ANS1939E  
NT Active Directory is not supported in this OS level.  
Explanation: NT Active Directory is not supported in this OS level.  
System Action: Processing stopped.  
User Response: Install Active Directory before performing backup operation.  
File Replication Service backup failed.  
Explanation: Tivoli Storage Manager encountered an error while backing up files  
under control of the Windows 2000 File Replication Service  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the File Replication Service is operating properly. Restart the service and  
retry the backup operation.  
ANS1940E  
ANS1941E  
ANS1942E  
File Replication Service restore failed.  
Explanation: Tivoli Storage Manager encountered an error while restoring files  
under control of the Windows 2000 File Replication Service  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the File Replication Service is operating properly. Restart the service and  
retry the restore operation.  
System Volume backup failed.  
Explanation: Tivoli Storage Manager encountered an error while backing up files  
of the Windows 2000 System Volume  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the system volume was successfully initialized. Restart the service and retry  
the backup operation  
System Volume restore failed.  
Explanation: Tivoli Storage Manager encountered an error while restoring files  
under control of the Windows 2000 File Replication Service  
System Action: Processing stopped.  
Tivoli Storage Manager Messages  
1189  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the system volume was successfully initialized. Restart the service and retry  
the restore operation.  
ANS2000I  
Unable to convert file names because MEMORYEFficientbackup option is ON.  
Explanation: TSM has detected that a local name space change has occurred on  
the volume that is currently being backed up. TSM would convert the file names to  
the new name space, but cannot because the option MEMORYEFficientbackup, is  
on.  
System Action: TSM continues to backup using the old name space.  
User Response: Edit the dsm.opt file, and set MEMORYEFficientbackup to OFF.  
ANS3000I  
ANS3001E  
communication-type communications available on port port-number.  
Explanation: The specified communications are available on the specified port  
number.  
System Action: None.  
User Response: None.  
Error initializing HTTPS communications - Secure HTTP not available.  
Explanation: An error occurred initializing HTTPS communications. Processing  
will continue, but secure HTTP communications will not be available.  
System Action: Processing continues, but secure HTTP communications will not  
be available.  
User Response: Check the console and error logs to determine why secure HTTP  
communications was unable to start, correct the problem, and restart the client.  
ANS3002I  
ANS3003I  
ANS3004E  
Session started for user userid (communication-method address).  
Explanation: A session was started for the specified user.  
System Action: None.  
User Response: None.  
Session ended for user userid.  
Explanation: A session ended for the specified user.  
System Action: None.  
User Response: None.  
Session for user userid terminated - invalid password entered.  
Explanation: A session was terminated for the specified user because an invalid  
password was entered.  
System Action: The session with the specified user is terminated.  
User Response: Re-start the remote client and enter the correct password for the  
specified user.  
1190  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS3005I  
Session for user userid terminated - idle for idle-minutes minutes.  
Explanation: A session was terminated for the specified user because there was no  
activity on the session for the specified number of minutes.  
System Action: The session with the specified user is terminated.  
User Response: Re-start the remote client to begin a new session.  
ANS3006I  
ANS3007I  
Processing request for the TSM Web Client (ip-address).  
Explanation: A request for the Web Client is being processed.  
System Action: None.  
User Response: None.  
TSM client-name terminating - idle for idle-minutes minutes.  
Explanation: The specified client is terminating because it has been idle for the  
specified time. It will be automatically started when it is needed.  
System Action: The client program stops.  
User Response: None.  
ANS1059E  
Two inactive objects with the same image name were selected. Process  
terminates  
Explanation: You selected more than one inactive version of the same image  
object (logical volume). The system has no way to decide which you want to  
restore.  
System Action: The requested logical volume restore is not performed.  
User Response: Retry the operation, selecting an active version or only one  
inactive version of the volume you wish to restore.  
ANS1060E  
ANS1061E  
The specified path is not a mounted filesystem  
Explanation: You entered a file system name that does not correspond to a  
mounted file system for this system. It is possible the file system name is  
misspelled, or simply that the file system is not currently mounted.  
System Action: The requested logical volume operation is not performed.  
User Response: Retry the operation, using name of a mounted file system.  
The specified device corresponds to a mounted file system, use the file system  
name.  
Explanation: You entered a logical device name that is mapped to a mounted file  
system. This volume must only be referenced by its file system name.  
System Action: The requested logical volume operation is not performed.  
User Response: Retry the operation, using the file system name.  
Tivoli Storage Manager Messages  
1191  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS1062E  
Only a single image may be selected when a destination is entered.  
Explanation: You selected more than one image object (logical volume) to be  
restored. You also specified a destination. The system cannot place more than one  
image into a single destination volume. When more than one object is selected, each  
must be restored to its original location.  
System Action: The requested logical volume restore is not performed.  
User Response: Retry the operation, selecting one object to be restored to the  
given destination, or retry the operation without entering the destination.  
1192  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Enterprise Management  
(2500–2999)  
ANS2600S  
ANS2601S  
ANS2602S  
Browser trying to establish connection to client; received socket exception:  
exception-name  
Explanation: The browser received the exception exception-name trying to  
connect to the TSM client machine.  
System Action: The TSM operation ends.  
User Response: Determine what might be causing this kind of an exception.  
Validate that the LAN is up and that you are trying to connect to the correct port  
number.  
Browser trying to establish connection to client; received unknown host  
exception: exception-name  
Explanation: The browser received the exception exception-name trying to  
connect to the TSM client machine.  
System Action: The TSM operation ends.  
User Response: Retry the operation. If it persists, determine what might be  
causing this kind of a problem. Determine if your LAN went down. Determine if  
you are trying to connect to the correct TSM client machine.  
Browser trying to establish connection to client; received IO exception:  
exception-name  
Explanation: The browser received the exception exception-name trying to  
connect to the TSM client machine.  
System Action: The TSM operation ends.  
User Response: Determine what might be causing this kind of an exception. Retry  
the problem, and check if the LAN is down.  
Tivoli Storage Manager Messages  
1193  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS2603S  
Browser trying to establish connection to client; received exception:  
exception-name  
Explanation: The browser received the exception exception-name trying to  
connect to the TSM client machine.  
System Action: The TSM operation ends.  
User Response: Determine what might be causing this kind of an exception.  
Determine if the LAN may be down, or if the TSM Client Acceptor Daemon on the  
TSM machine is up and running.  
ANS2604S  
The Web client agent was unable to authenticate with the server.  
Explanation: The TSM Web client agent was unable to authenticate with the TSM  
server.  
System Action: The TSM operation ends.  
User Response: One possible solution is to run the command line client so that  
the client password can be re-entered. Another approach is to check the error log on  
the TSM Web client agent for any relevant messages.  
ANS2605S  
Browser could not re-establish connection to client; received protocol error.  
Explanation: The browser received a protocol error trying to re-connect to the  
TSM client machine.  
System Action: The TSM operation ends.  
User Response: Determine what might be causing this kind of an error. Determine  
if the TSM browser and the TSM client code might be out of sync.  
ANS2606S  
ANS2607S  
An invalid password was sent to the server.  
Explanation: The TSM password that was sent to the TSM server was invalid.  
System Action: The TSM operation ends.  
User Response: Make sure that you have the correct password. Also make sure  
that it is valid, for example it is not too short.  
Browser could not establish connection to client.  
Explanation: The TSM browser could not connect to the TSM client machine.  
System Action: The TSM operation ends.  
User Response: Determine what might be causing this kind of a problem.  
Determine if the LAN is down, or if the TSM Client Acceptor Daemon on the TSM  
machine is up and running.  
ANS2608S  
Nothing was selected so no operation was performed.  
Explanation: No object was selected in the GUI for the operation to be performed  
upon.  
System Action: The TSM operation ends.  
User Response: Make sure you select one or more objects (volume, directory or  
file) in the GUI before clicking on the operation to be performed.  
1194  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS2609S  
TCP/IP communications failure between the browser and the client machine.  
Explanation: This error can occur due to any of the following:  
The LAN connection to the TSM client machine went down.  
You are trying to connect to the TSM client machine using the wrong port  
number.  
The Client Acceptor Daemon on the TSM client machine is not up and running  
and accepting connections.  
System Action: The TSM operation ends.  
User Response: Retry the operation and make sure the LAN is up. Also check that  
the port number is correct, and that the Client Acceptor Daemon is started and  
running on the TSM client machine, and that it is listening on the correct port  
number.  
ANS2610S  
TCP/IP communications failure between the client and the server machine.  
Explanation: This error can occur if the LAN connection between the TSM client  
machine and the server machine went down.  
System Action: The TSM client ends.  
User Response: Retry the operation and make sure the LAN is up. Make sure that  
both the TSM server and the TSM client are up and running.  
ANS2611S  
ANS2612S  
An unknown error occurred in the browser.  
Explanation: An unknown error occurred in the applet running in the browser.  
System Action: The TSM operation ends.  
User Response: Retry the operation. If the problem persists, turn on tracing and  
see if the trace to the browser console gives the reason for the error.  
An unknown error occurred in the client Please check the TSM Error Log for  
any additional information  
Explanation: An unknown error occurred in the TSM client.  
System Action: The TSM client ends.  
User Response: Retry the operation. If the problem persists, check the TSM Error  
Log for any additional information.  
ANS2613S  
A protocol error occurred in communications between the browser and the  
client.  
Explanation: A protocol error happened between the applet running in the browser  
and the TSM client.  
System Action: The TSM operation ends.  
User Response: Retry the operation. If the problem persists, turn on tracing and  
see if the trace to the browser console gives the reason for the error.  
Tivoli Storage Manager Messages  
1195  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS2614S  
A protocol error occurred in communications between the client and the server.  
Explanation: A protocol error happened between the TSM client and the TSM  
server.  
System Action: The TSM client ends.  
User Response: Retry the operation. If the problem persists, check the TSM Error  
Log for any additional information. Verify that you are running the correct applet  
with the appropriate level of the client.  
ANS2615S  
The user ID entered does not match the nodename configured on the client  
machine.  
Explanation: The user ID that was entered is not the same as the nodename on  
this TSM client.  
System Action: The TSM operation ends.  
User Response: Verify that the nodename entered is configured correctly on the  
TSM client.  
ANS2617S  
ANS2618S  
The destination directory specified is invalid.  
Explanation: The user specified a destination target directory for restore or  
retrieve which is invalid.  
System Action: The TSM operation ends.  
User Response: Retry the operation specifying a valid directory name.  
Browser trying to retrieve resources; received resource exception:  
exception-name  
Explanation: The browser received the exception exception-name trying to retrieve  
resources from the TSM client machine.  
System Action: The TSM operation ends.  
User Response: Verify that the resources are installed correctly on the TSM client  
machine.  
ANS2619S  
ANS2620W  
The Client Acceptor Daemon was unable to start the Remote Client Agent.  
Explanation: The TSM Client Acceptor Daemon could not start the TSM Remote  
Client Agent.  
System Action: The TSM operation ends.  
User Response: Check the error log on the TSM Web client agent for any relevant  
messages. Then correct the problem and retry.  
The expand entire branch operation may take a long time, and cannot be  
canceled once it has started. Are you willing to wait for the operation to  
complete?  
Explanation: The expand entire branch operation could take a long time and  
cannot be canceled once it is started.  
System Action: Processing stopped; waiting for user intervention.  
1196  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Answer 'Yes' to start the expand entire branch operation. If you  
answer 'No', the current operation will be canceled.  
ANS2621W  
This function is not available on the client platform  
Explanation: The browser received a request that is not available on the TSM  
client machine. For example, registry backup and restore are available only on the  
Windows platform.  
System Action: The TSM operation ends.  
User Response: Request only those functions that are valid for the platform of the  
TSM client machine.  
ANS2622S  
ANS2623S  
Invalid ID or password submitted.  
Explanation: An invalid ID or an invalid password was submitted.  
System Action: The TSM operation ends.  
User Response: Verify that the ID and the password that you entered are correct.  
If going to a different server (for example by hyperlinking) then make sure that the  
different server has the same ID defined with the same password.  
Web Client applet level is out of sync with Web Client agent.  
Explanation: The Web Client applet and Web Client agents are at incompatible  
levels.  
System Action: The TSM operation ends.  
User Response: Verify that you have the correct level of the applet installed with  
the client, and that an incorrect level of the applet was not placed in the install  
directory.  
ANS2624E  
ANS2625E  
This operation requires client owner authority.  
Explanation: Your user ID has insufficient authority to perform this operation.  
System Action: Processing continues, but the user is not allowed to do this  
operation.  
User Response: Do not perform this operation, or get a higher authority level for  
your user ID in order to perform this operation.  
Node does not support this image operation.  
Explanation: Node does not support or is not configured to perform this image  
operation.  
System Action: Processing continues, but the user is not allowed to do this  
operation.  
User Response: Verify whether this image related operation is supported or  
configured on the target platform.  
Tivoli Storage Manager Messages  
1197  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS2641E  
ANS2642E  
Registry Backup failed  
Explanation: TSM An error occurred while backing up the registry.  
System Action: Registry backup function fails.  
User Response: See your system administrator.  
An Error occurred creating the registry directory structure  
Explanation: An error occurred while creating the directory structure to  
save/replace registry key.  
System Action: Registry function fails.  
User Response: See your system administrator.  
ANS2643E  
ANS2650E  
An error occurred saving the registry key  
Explanation: The active registry key cannot be saved.  
System Action: Registry backup operation terminates.  
User Response: See your system administrator.  
An error occurred replacing the registry key  
Explanation: The backed up registry key(s) were restored from the server but  
cannot be made active into the registry.  
System Action: Current Registry key remains active.  
User Response: See your system administrator.  
ANS2660E  
ANS2662E  
ANS2663E  
ANS2664E  
Registry activation failed  
Explanation: An error occurred while restoring the registry key from the server.  
System Action: Registry restore function fails.  
User Response: See your system administrator.  
Event Log Backup failed  
Explanation: TSM An error occurred while backing up the event logs.  
System Action: Event log backup function fails.  
User Response: See your system administrator.  
Event Log Restore failed  
Explanation: An error occurred while restoring the event logs from the server.  
System Action: Event Log restore function fails.  
User Response: See your system administrator.  
An Error occurred creating the event log directory structure  
Explanation: An error occurred while creating the directory structure to save the  
event logs.  
System Action: Event Log function fails.  
User Response: See your system administrator.  
1198  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Client Event Logging  
(4000–4999)  
ANS4000E  
Error processing ’filespace-name’: file space does not exist  
Explanation: The specified file space (domain) is incorrect or does not exist on  
the workstation. If the message results from the BACKUP IMAGE command with  
the -MODE=INCREMENTAL option, it may mean that you have entered the name  
of a raw logical volume. The MODE=INCREMENTAL option is not valid for raw  
logical volumes.  
System Action: Processing stopped.  
User Response: Retry the operation specifying an existing domain (drive letter or  
file system name). If the message resulted from improper use of the  
MODE=INCREMENTAL option, retry the command, omitting that option.  
ANS4001E  
ANS4002E  
Error processing ’filespace-name’: file space not known to server  
Explanation: The number defining the correspondence between drive letter or file  
(domain name) and volume label is not known to the server.  
System Action: Processing stopped.  
User Response: Report the program error to your service representative.  
Error processing ’filespace-name’: volume label does not exist  
Explanation: The selected drive does not have a label.  
System Action: TSM is unable to do the requested operation without a drive or  
label entered.  
User Response: If the drive is a floppy drive, place a disk with a volume label in  
it and retry the operation. If the disk is a hard drive, ensure the drive has a volume  
label, and retry the operation.  
Tivoli Storage Manager Messages  
1199  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS4003E  
Error processing ’filespace-name’: duplicate volume label encountered  
Explanation: The selected drive has a duplicate volume label. Because TSM uses  
the volume label to keep track of backup/archive information, it cannot back up or  
archive files from a drive with a duplicate volume label.  
System Action: TSM cannot select the drive.  
User Response: If the volume needs to be available to the system, exit TSM, and  
assign a volume label to the drive. Restart TSM and retry the operation.  
ANS4004E  
Error processing ’filespace namepath-namefile-name’: destination file or  
directory is write locked  
Explanation: The file or directory being restored or retrieved from the server  
cannot be written to because the destination is write locked. Another operation  
might have the file open and will not allow it to be updated.  
System Action: File skipped.  
User Response: Either determine which operation has the file write locked, or  
restore the file to another name or location.  
ANS4005E  
ANS4006E  
Error processing ’filespace namepath-namefile-name’: file not found  
Explanation: The file being processed for backup, archive or migrate no longer  
exists on the client. Another process deletes the file before it can be backed up,  
archived or migrated by TSM.  
System Action: File skipped.  
User Response: None.  
Error processing ’filespace namepath-namefile-name’: directory path not found  
Explanation: You have specified a directory that does not exist as shown on your  
workstation.  
System Action: Processing stopped.  
User Response: Recheck all spelling and punctuation, particularly the placement  
of directory delimiters (for example, \). Correct the syntax, then retry the  
operation.  
ANS4007E  
Error processing ’filespace namepath-namefile-name’: access to the object is  
denied  
Explanation: Access to the specified file or directory is denied. You tried to read  
from or write to a file and you do not have access permission for either the file or  
the directory.  
System Action: Processing stopped.  
User Response: Ensure that you specified the correct file or directory name,  
correct the permissions, or specify a new location.  
1200  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS4008E  
ANS4009E  
Error processing ’filespace namepath-namefile-name’: file is temporarily  
unavailable  
Explanation: File is temporarily unavailable.  
System Action: File skipped.  
User Response: Check and see if file is locked by other process. If not, retry the  
command.  
Error processing ’filespace namepath-namefile-name’: disk full condition  
Explanation: No more files can be restored or retrieved because the destination  
disk is full.  
System Action: Processing stopped.  
User Response: Free up disk space, or restore or retrieve the file to another disk.  
ANS4010E  
ANS4011E  
Error processing ’filespace namepath-namefile-name’: stale NFS handle  
Explanation: An NFS file system becomes stale.  
System Action: File system skipped.  
User Response: Check the NFS mounted filesystem.  
Error processing ’filespace namepath-namefile-name’: no file handles available  
Explanation: All file handles for your system are currently in use. No more are  
available.  
System Action: Processing stopped.  
User Response: Either free some file handles by ending other processes, or modify  
your system setup to allow for more files to be open at the same time.  
ANS4012E  
ANS4013E  
Error processing ’filespace namepath-namefile-name’: file already exists  
Explanation: The file being restored or retrieved exists.  
System Action: File is replaced or skipped depending on client options.  
User Response: None.  
Error processing ’filespace namepath-namefile-name’: invalid file handle  
Explanation: An internal system error occurred. A file operation failed because an  
invalid file handle was passed.  
System Action: Processing stopped.  
User Response: Report the problem to your system administrator, and then retry  
the operation.  
ANS4014E  
Error processing ’filespace namepath-namefile-name’: unknown system error  
(error-code) encountered. Program ending.  
Explanation: An unknown and unexpected error-code occurred within the client  
program. This is a programming failure and the client program ends.  
System Action: Processing stopped.  
Tivoli Storage Manager Messages  
1201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Retry the operation. If the problem continues, see your  
administrator.  
ANS4015E  
ANS4016E  
ANS4017E  
Error processing ’filespace namepath-namefile-name’: unexpected error  
(error-code) encountered  
Explanation: An unexpected error occurred. This might be a low-level system or  
communication error that TSM cannot handle or recover from.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, determine where  
the problem exists. See your system administrator for further help.  
Error processing ’filespace namepath-namefile-name’: file is being executed;  
write permission denied  
Explanation: The current file cannot be opened to write to because it is currently  
being run by another operation.  
System Action: File skipped.  
User Response: Stop the operation that is running the file and retry the operation,  
or restore or retrieve the file to a different name or directory.  
Error processing ’filespace namepath-namefile-name’: too many symbolic links  
were detected while resolving name  
Explanation: While trying to resolve the file name, too many symbolic links were  
found.  
System Action: File skipped.  
User Response: Ensure that you do not have a looping symbolic link for the file.  
ANS4018E  
ANS4019E  
ANS4020E  
Error processing ’filespace namepath-namefile-name’: file name too long  
Explanation: The file name specified is too long to be handled by TSM.  
System Action: File is skipped.  
User Response: See the appropriate Using the Backup-Archive Client book for the  
particular operating system, for the file names that are handled by TSM.  
Error processing ’filespace namepath-namefile-name’: file system is locked by  
system  
Explanation: File system cannot be accessed because it is locked by the system.  
System Action: TSM cannot complete the operation.  
User Response: See your system administrator.  
Error processing ’filespace namepath-namefile-name’: format unknown  
Explanation: TSM tried to restore or retrieve a file, but it had an unknown format.  
System Action: File skipped.  
User Response: See your system administrator.  
1202  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS4021E  
ANS4022E  
Error processing ’filespace namepath-namefile-name’: file system not ready  
Explanation: The file system/drive was not ready for access.  
System Action: Processing stopped.  
User Response: Ensure that the drive is available to TSM, and then retry the  
operation.  
Error processing ’filespace namepath-namefile-name’: file system is invalid  
Explanation: The drive was not available for access. A directory exists that does  
not have either a '.' or '..' entry.  
System Action: Processing stopped.  
User Response: Ensure that the drive is operational, and then retry the operation.  
If unsuccessful, have your service representative check the error log.  
ANS4023E  
Error processing ’filespace namepath-namefile-name’: file input/output error  
Explanation: An error was found while reading from or writing to the file.  
System Action: File skipped.  
User Response: Check your system to ensure that it is operating properly. For  
OS/2, run CHKDSK /F for the failing drive which can be found in dsmerror.log.  
ANS4024E  
ANS4025E  
Error processing ’filespace namepath-namefile-name’: file write error  
Explanation: An error was found while writing to the file.  
System Action: File skipped.  
User Response: Check your system to ensure that it is operating properly.  
Error processing ’filespace namepath-namefile-name’: file exceeds user or system  
file limit  
Explanation: A file being restored or retrieved exceeds system set limits for this  
user.  
System Action: File skipped.  
User Response: Ensure that the system limits are set properly.  
ANS4026W  
Error processing ’filespace namepath-namefile-name’: size of ’file-size’ exceeded  
the maximum file size limit on your system  
Explanation: You tried to restore or retrieve a file that has exceeded the maximum  
file size limitation on your system.  
System Action: TSM cannot restore or retrieve the file.  
User Response: Restore or retrieve this file on a system that supports the file size.  
See your system administrator.  
Tivoli Storage Manager Messages  
1203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS4027S  
ANS4028E  
ANS4029E  
Error processing ’filespace namepath-namefile-name’: internal program message  
value’ encountered  
Explanation: An unexpected catastrophic program failure occurred, indicated by  
value.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, see your system  
administrator or service representative.  
Error processing ’filespace namepath-namefile-name’: cannot create file/directory  
entry  
Explanation: The directory path for files being restored or retrieved cannot be  
created.  
System Action: File skipped.  
User Response: Ensure that you have the proper authorization to create the  
directory for file being restored or retrieved.  
Error processing ’filespace namepath-namefile-name’: unable to build a directory  
path; a file exists with the same name as a directory  
Explanation: TSM tried to create a directory path, but is unable to because a file  
exists that has the same name as a directory.  
System Action: Processing stopped.  
User Response: Remove the file that has the same name as the directory. Refer to  
the last restore/retrieve operation and check all directories along the path.  
ANS4030E  
ANS4031E  
Error processing ’filespace namepath-namefile-name’: disk space limit for this  
process reached  
Explanation: The disk space allocated for the client owner is full.  
System Action: Processing stopped.  
User Response: Free up disk space and retry the restore or retrieve operation.  
Error processing ’filespace namepath-namefile-name’: destination directory path  
length exceeds system maximum  
Explanation: The path name specified plus the path name in the restored file  
name combine to create a name whose length exceeds the system maximum.  
System Action: Processing stopped.  
User Response: Specify a destination path that, when combined, is less than the  
system maximum.  
ANS4032E  
Error processing ’filespace namepath-namefile-name’: file is not compressed.  
Explanation: A file that was flagged as compressed was not compressed, and the  
system failed.  
System Action: Processing stopped.  
1204  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: See your system administrator to report this problem. This error is  
a system failure.  
ANS4033E  
Error processing ’filespace namepath-namefile-name’: file compressed on a  
different client machine that has more memory  
Explanation: You are trying to restore a file that was backed up and compressed  
on another client workstation that had more memory than your client workstation.  
You cannot restore this file. When the file is restored, it is expanded and your  
workstation does not have enough memory.  
System Action: TSM canceled the operation.  
User Response: Obtain a machine with more memory and retry the operation.  
ANS4034E  
ANS4035W  
Error processing ’filespace namepath-namefile-name’: unknown system error  
Explanation: An unknown error occurred. This might be a low-level system or  
communication error that TSM cannot handle or recover from.  
System Action: Processing stopped.  
User Response: Retry the operation. If the problem continues, determine where  
the problem exists. See your system administrator for further help.  
File ’filespace namepath-namefile-name’ currently unavailable on server.  
Explanation: You tried to restore or retrieve a file that is currently not available  
from the TSM server.  
System Action: TSM Cannot restore or retrieve the file.  
User Response: Try to restore or retrieve after the file was made available on the  
server. See your system administrator.  
ANS4036E  
ANS4037E  
An error occurred saving the registry key.  
Explanation: The active registry key cannot be saved.  
System Action: Registry backup operation terminates.  
User Response: See your system administrator.  
File ’file-namefile-namefile-name’ changed during processing. File skipped.  
Explanation: The specified file-name was skipped during backup, archive, or  
migrate because it was changing during the attempt to process it.  
System Action: TSM skipped the file.  
User Response: If you want the file backed up, archived, or migrated, retry the  
operation. If it fails, determine why the file is being changed. For more information  
on backing up, archiving, or migrating changing files, see your system administrator.  
ANS4040E  
Error processing ’filespace namepath-namefile-name’: file system filespace name  
has exceeded its space management quota.  
Explanation: TSM detects that the file system has exceeded its quota. No more  
data can be migrated out of this file system.  
Tivoli Storage Manager Messages  
1205  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM will not migrate files from this file system.  
User Response: Recall some files, or ask the system administrator to increase the  
quota for this file system.  
ANS4041W  
Error processing ’filespace namepath-namefile-name’: Out of free space or inodes  
in file system to migrate or recall.  
Explanation: The file system is full. No more free space or free inodes are  
available to be allocated for the transaction file that is needed when a file is being  
migrated or recalled.  
System Action: TSM terminates the current operation for this file system.  
User Response: Remove some files in the file system, and then run reconciliation.  
Retry the operation.  
ANS4042E  
ANS4900W  
Object name ’filespace namepath-namefile-name’ contains one or more  
unrecognised characters and is not valid.  
Explanation: The filename, directory name, or volume label syntax is incorrect.  
System Action: File skipped.  
User Response: You need to check the disk for errors.  
Schedule ’schedule name’ has opened a new session with the server.  
Explanation: A scheduled event ended due to a connection failure. The scheduled  
event had to be restarted outside it's normal start-up window to continue the  
operation.  
System Action: Be advised that there are multiple sessions associated with the  
scheduled event.  
User Response: none.  
ANS4987E  
Error processing ’filespace namepath-name file-name’: the object is in use by  
another process  
Explanation: Access to the specified file or directory is denied. You tried to read  
from or write to a file and you do not have access permission for either the file or  
the directory.  
System Action: Processing stopped.  
User Response: Ensure that you specified the correct file or directory name,  
correct the permissions, or specify a new location.  
ANS4988W  
File ’filespace namepath-namefile-name’ is currently unavailable on server and  
has been skipped.  
Explanation: You tried to restore or retrieve a file that is currently not available  
from the TSM server.  
System Action: TSM cannot restore or retrieve the file.  
User Response: Try to restore or retrieve after the file was made available on the  
server. See your system administrator.  
1206  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS4999E  
Unable to log message ’message number’ to server: message too long.  
Explanation: The message text and inserts were too large to send to the server in  
the available internal buffer.  
System Action: Refer to the local client error log for more information  
User Response: None.  
Tivoli Storage Manager Messages  
1207  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1208  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Graphical User Interface Client  
(5000–5999)  
ANS5000W  
Unable to update password  
Explanation: Intended new password cannot be registered.  
System Action: The server did not replace the old password with the new  
password.  
User Response: Update the password again. If unsuccessful, see your system  
administrator.  
ANS5001E  
ANS5002E  
Open registration required. Root user must run TSM to register with server  
Explanation: This client must be registered with this server.  
System Action: TSM ends.  
User Response: The root user must register the client with the server.  
Open registration failed  
Explanation: During the change password, update password, or open register  
dialog, the open registration failed.  
System Action: TSM did not register this system.  
User Response: Reenter the password, or see your system administrator to register  
this system.  
ANS5003S  
Invalid Management Class assigned to directories. Please see the error log.  
Explanation: An invalid management class was assigned.  
System Action: TSM cannot perform the requested operation.  
User Response: Retry the operation using a valid management class. If  
unsuccessful, have your service representative check the error log.  
Tivoli Storage Manager Messages  
1209  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS5004S  
ANS5005W  
No backup copy group in the management class used for directories. Please see  
the error log.  
Explanation: The management class contained no backup copy group for  
directories.  
System Action: TSM did not complete the backup operation.  
User Response: Have your service representative check the error log.  
The policy set does not contain any backup copy groups. If you continue with  
the incrementalbackup any currently backed up files will be deactivated on the  
server and assigned to the Backup Grace Period. Do you wish to continue?  
Explanation: You tried to back up the files using a policy set that contains no  
backup management information (the copy group).  
System Action: If you continue with the incremental backup, any currently backed  
up files are deactivated on the server and assigned the Backup Grace Period, as  
defined by your system administrator.  
User Response: Change the management class that binds the files, or accept the  
Backup Grace Period.  
ANS5006W  
The policy set does not contain any backup copy groups. Unable to continue  
with backup.  
Explanation: You tried to back up the files using a policy set that contained no  
backup management information (the copy group).  
System Action: TSM did not back up the file(s).  
User Response: Change the management class that binds the files, and retry the  
operation.  
ANS5007W  
The policy set does not contain any archive copy groups. Unable to continue  
with archive.  
Explanation: You tried to archive the files using a policy set that contains no  
archive management information (the copy group).  
System Action: TSM did not archive the files.  
User Response: Change the management class that binds the files, and retry the  
operation.  
ANS5008W  
ANS5009W  
Incorrect password entered  
Explanation: You entered a password that was incorrect.  
System Action: TSM cannot connect to the server without the correct password.  
User Response: Reenter the password, or ask your system administrator for the  
current password.  
New password entries are not the same  
Explanation: During the change password, update password, or open register  
dialog, the two entries for the new password were not the same.  
1210  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: The password was not changed on the server.  
User Response: Backspace over both of the new passwords and reenter them,  
ensuring that they match.  
ANS5010S  
Authentication failed - session not started  
Explanation: You typed an incorrect password four times in a row.  
System Action: TSM cannot connect to the server without a correct password.  
User Response: Exit and restart TSM if authorized; otherwise, see your system  
administrator.  
ANS5011I  
ANS5012E  
Backup stopped by user  
Explanation: You requested to stop the backup operation.  
System Action: Backup stopped.  
User Response: Continue with normal operations.  
Server out of backup data storage space  
Explanation: The server ran out of space in its backup data storage.  
System Action: TSM cannot complete the requested backup operation. Any files  
displayed on the lower half of the backup activity panel were successfully backed  
up.  
User Response: See your system administrator.  
ANS5013E  
Not enough memory for backup operation  
Explanation: TSM cannot allocate memory for the specified backup operation.  
System Action: TSM cannot complete the requested operation.  
User Response: Close all unneeded applications and retry the operation. Reducing  
the scope of queries and the amount of data returned might also help, or see your  
system administrator.  
ANS5014I  
ANS5015I  
Backup completed  
Explanation: The backup was completed.  
System Action: TSM backed up the files.  
User Response: Continue with normal operations.  
Restore stopped by user  
Explanation: You requested to stop the restore operation.  
Attention: If you were restoring files with “overwrite” option specified, the file  
you restored last can be damaged (partially overwritten).  
System Action: Restore stopped.  
User Response: Continue with normal operations.  
Tivoli Storage Manager Messages  
1211  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5016E  
Not enough memory for restore operation  
Explanation: TSM cannot allocate memory for the requested restore operation.  
System Action: TSM cannot complete the requested restore operation.  
User Response: Close all unneeded applications and retry the operation. Reducing  
the scope of queries and the amount of data returned can also help, or see your  
system administrator.  
ANS5017I  
ANS5018E  
Restore completed  
Explanation: A restore was completed.  
System Action: TSM restored the files.  
User Response: Continue with normal operations.  
Not enough memory for archive operation  
Explanation: TSM cannot allocate memory for the requested archive operation.  
System Action: TSM cannot complete the archive operation.  
User Response: Close all unneeded applications and retry the operation. Reducing  
the scope of queries and the amount of data returned might also help, or see your  
system administrator.  
ANS5019I  
ANS5020E  
Archive stopped by user  
Explanation: You requested to stop the archive operation.  
System Action: Archive stopped.  
User Response: Continue with normal operations.  
Server out of archive data storage space  
Explanation: The server ran out of space in its archive data storage.  
System Action: TSM cannot complete the requested archive operation. Any files  
displayed on the lower half of the archive activity panel were successfully archived.  
User Response: See your system administrator.  
ANS5021I  
ANS5022I  
Archive completed  
Explanation: An archive was completed.  
System Action: TSM archived the files.  
User Response: Continue with normal operations.  
Retrieve stopped by user  
Explanation: You requested to stop the retrieve operation.  
Attention: If you were retrieving files with “overwrite” option specified, the file  
you retrieved last can be damaged (partially overwritten).  
System Action: Retrieve stopped.  
User Response: Continue with normal operations.  
1212  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5023E  
Not enough memory for retrieve operation  
Explanation: TSM cannot allocate memory for the specified retrieve operation.  
System Action: TSM cannot complete the requested retrieve operation.  
User Response: Close all unneeded applications and retry the operation. Reducing  
the scope of queries and the amount of data returned might also help, or see your  
system administrator.  
ANS5024I  
ANS5025E  
ANS5026W  
Retrieve completed  
Explanation: A retrieve was completed.  
System Action: TSM retrieved the files.  
User Response: Continue with normal operations.  
The nodename contains invalid characters.  
Explanation: The specified node name has invalid characters.  
System Action: TSM canceled the current operation.  
User Response: Retry with another node name that has valid characters.  
MatchAllChar and MatchOneChar options MUST precede Include/Exclude  
options  
Explanation: The MatchAllChar and MatchOneChar options must precede any  
include-exclude options.  
System Action: The TSM client ends the current application.  
User Response: Move the MatchAllChar and MarchOneChar options before any  
include-exclude options.  
ANS5091S  
ANS5092S  
Unexpected Wait_For_Space from the server.  
Explanation: The client received an unexpected Wait For Space message from the  
server.  
System Action: TSM ended the current operation.  
User Response: See your system administrator.  
Server out of data storage space.  
Explanation: The server does not have any more space available to store the  
object.  
System Action: TSM ended the current operation.  
User Response: Report to your system administrator that a storage pool on the  
server is full.  
ANS5093S  
SLM_LICENSE_EXCEEDED: The client licenses for TSM are exceeded. See  
your system administrator.  
Explanation: Adding a new enrollment will exceed the product license count for  
TSM  
Tivoli Storage Manager Messages  
1213  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Execution of the client enrollment or connection request ends.  
User Response: See your system administrator.  
ANS5094E  
ANS5122E  
Session Rejected. Sufficient server memory is not available.  
Explanation: The server does not have enough memory to allow your client to  
establish a connection with the server.  
System Action: Session was not started.  
User Response: Retry later or see your system administrator.  
The specified filespace does not exist on the server. The filespace might have  
been deleted by another client or an administrator.  
Explanation: The specified filespace does not exist on the server. Your  
administrator might have already deleted the filespace or another client using your  
client's node name might have deleted it.  
System Action: TSM ends the current operation.  
User Response: Retry your operation. The filespace you were working on should  
not exist any more. See your system administrator for more information.  
ANS5123S  
Open registration failed because the specified node name is already defined in  
the server.  
Explanation: Open registration failed because a node is defined on the server with  
the same name.  
System Action: TSM canceled the current operation.  
User Response: Retry with another node name.  
ANS5124S  
ANS5125S  
Open registration failed because there is no default domain.  
Explanation: Open registration failed because a default policy domain does not  
exist for you to place your node.  
System Action: TSM canceled the current operation.  
User Response: See your system administrator.  
Open registration failed because an invalid node name was specified.  
Explanation: Open registration failed because the specified node name has invalid  
characters.  
System Action: TSM canceled the current operation.  
User Response: Retry with another node name that does not have any invalid  
characters.  
ANS5126S  
Filespaces with duplicate names are not supported. Please unmount the  
duplicate filespace.  
Explanation: The selected filespace has a duplicate volume label. Because TSM  
uses the volume label to keep track of backup/archive information, it cannot back  
up or archive files from a filespace with a duplicate volume label.  
1214  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM cannot select the volume.  
User Response: If the filespace needs to be available to the system, exit TSM, and  
assign a volume label to the filespace. Restart TSM and retry the operation.  
Otherwise, unmount the duplicate filespace.  
ANS5127W  
File excluded  
Explanation: A file cannot be processed because it is explicitly excluded by the  
include-exclude list defined in the options file.  
System Action: TSM did not back up the file.  
User Response: Look in the options file for the include-exclude list of that file.  
Consider changing the options file or see your system administrator.  
ANS5128E  
ANS5129E  
No Backup Copy Group  
Explanation: The management class for this file did not have a backup copy  
group specified.  
System Action: TSM did not back up the file.  
User Response: See your system administrator.  
No Archive Copy Group  
Explanation: The management class for this file did not have an archive copy  
group specified.  
System Action: TSM did not archive the file.  
User Response: See your system administrator.  
ANS5130W  
ANS5131S  
No filespaces selected for deletion  
Explanation: You requested a deletion operation without selecting a client domain.  
System Action: TSM cannot perform a deletion without a domain selected.  
User Response: Select the volumes you want to delete and retry the operation.  
Severe error: Filespace not found on server  
Explanation: TSM cannot find the requested filespaces on the server.  
System Action: TSM did not delete the filespaces.  
User Response: Go to the main window, refresh the filespaces, and retry the  
deletion operation.  
ANS5132I  
Filespace deletion canceled by user  
Explanation: You requested to cancel the filespace deletion operation.  
System Action: The filespace deletion operation stopped.  
User Response: Continue with normal operations.  
Tivoli Storage Manager Messages  
1215  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5133I  
ANS5134E  
Filespace ’filespace’ was deleted  
Explanation: The specified filespace was successfully deleted.  
System Action: TSM deleted the filespace.  
User Response: Continue with normal operations.  
Unable to delete the filespace because this node does not have permission to  
delete archived data and/or backed up data.  
Explanation: You tried to delete a filespace that you do not have permission to  
access.  
System Action: TSM canceled the operation.  
User Response: Ensure that you specify the correct filespace, or specify a  
filespace you have access to.  
ANS5135I  
ANS5136E  
Archive delete stopped by user  
Explanation: You requested to stop the archive delete operation.  
System Action: Archive delete stopped.  
User Response: Continue with normal operations.  
Not enough memory for archive delete operation  
Explanation: TSM cannot allocate memory for the specified archive delete  
operation.  
System Action: TSM cannot continue with the requested archive delete operation.  
User Response: Close all unneeded applications and retry the operation. Reducing  
the scope of queries and the amount of data returned might also help, or see your  
system administrator.  
ANS5137E  
Server out of archive data storage space  
Explanation: The server reported an out of space condition during an archive  
delete operation.  
System Action: TSM cannot continue with the requested operation. All files listed  
in the lower half of the activity window were deleted.  
User Response: Report to your system administrator how you received this  
condition.  
ANS5138I  
ANS5139E  
Archive delete completed  
Explanation: An archive delete was completed.  
System Action: TSM deleted the archived files.  
User Response: Continue with normal operations.  
Your node does not have permission to delete archived files.  
Explanation: Your node is not allowed by the server to delete archived files.  
System Action: TSM did not delete the archived files.  
1216  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: See your system administrator.  
ANS5145W  
ANS5146W  
Server cannot restart the last restore request. Do you want to restore without  
restart?  
Explanation: The restart restore token has expired. The server cannot restart the  
restore from where it last ended.  
System Action: Processing stopped; waiting for user intervention.  
User Response: Retry the request without restart or abort the request.  
You cannot perform this operation while accessing data for another node. Do  
you wish to switch back to accessing your own node?  
Explanation: The user cannot perform the selected operation while accessing  
another users data.  
System Action: Processing stopped; waiting for user intervention.  
User Response: Answer Yesto switch back to accessing the server as the  
original node.  
ANS5148W  
The server needs to do a one-time conversion of your archive data before you  
can continue. This operation may take a long time, and cannot be canceled  
once it has started. Are you willing to wait for the conversion to complete?  
Explanation: The server must do a conversion of the archive data before  
continuing. The conversion could take a long time, and cannot be canceled once it  
is started.  
System Action: Processing stopped; waiting for user intervention.  
User Response: Answer “Yes” to start the archive data conversion. If you answer  
“No”, the current operation will be canceled.  
ANS5149W  
ANS5150E  
The archive description you specified is not unique. Please enter a unique  
archive description.  
Explanation: Descriptions for archive files must be unique per archive operation.  
System Action: Processing stopped.  
User Response: Enter an archive description that is unique.  
An active restore for the same source file specification exists. Unable to  
continue with this request.  
Explanation: Currently, there is an active restore for the same source file  
specification. Another restore of the same source file specification cannot be started.  
System Action: The requested restore fails.  
User Response: Start another restore with a different source file specification.  
Tivoli Storage Manager Messages  
1217  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5151S  
This node currently has a pending restartable restore session. The requested  
operation cannot complete until this session either completes or is canceled.  
Explanation: This operation can not be completed because a restartable restore  
session is pending. The operation is not allowed because the restartable session and  
the current operation affect the same file space.  
System Action: TSM ended the current operation.  
User Response: Issue a query restart to see the conflict. Issue the cancel restore  
command to delete any unneeded restartable restore sessions.  
ANS5152S  
ANS5153E  
Session Rejected: The server is not licensed for this platform type. See your  
system administrator.  
Explanation: The server is not licensed for the requesting client type.  
System Action: Execution of the client enrollment or connection request ends.  
User Response: See your system administrator.  
Session Rejected: The server does not allow a signon as a Unicode enabled  
client.  
Explanation: The client cannot establish a connection to the server because of a  
unicode enabling mismatch between server and client.  
System Action: Session was not started.  
User Response: See your system administrator immediately.  
ANS5154I  
ANS5155E  
File is implicitly excluded  
Explanation: You tried to back up or migrate a file that is implicitly excluded.  
System Action: TSM will not back up or migrate an implicitly excluded file.  
User Response: None.  
Valid password not available. The TSM administrator for your system must  
run TSM and enter the password to store it locally.  
Explanation: The file containing the stored password for the specified server  
server-name is unavailable.  
System Action: TSM ends.  
User Response: The TSM administrator for your system must set and store a new  
password.  
ANS5157E  
This action requires TSM administrative authority on this system.  
Explanation: An activity has been attempted that must be performed by the TSM  
administrator (for example, open registration, filespace delete or password update).  
System Action: TSM canceled the operation.  
User Response: If the activity is required, the TSM administrator for this system  
must perform it.  
1218  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5158S  
ANS5160W  
Filespace deletion is in progress. Try again later.  
Explanation: The filespace is in the process of being deleted.  
System Action: TSM cannot complete the requested operation.  
User Response: Try the operation again later. If the filespace was being deleted, it  
could take awhile for it to complete. If the problem continues, report the problem to  
your system administrator.  
Unable to locate resource file filename. Using resource file filename instead.  
Explanation: TSM cannot locate the specified resource file. The english version of  
the resource file is being used instead.  
System Action: Processing continues  
User Response: Verify that TSM was installed and configured correctly. If the  
problem continues, report the problem to your system administrator.  
ANS5161E  
ANS5162E  
ANS5164E  
Unable to locate resource file filename.  
Explanation: TSM cannot locate the specified resource file.  
System Action: Processing stops.  
User Response: Verify that TSM was installed and configured correctly. If the  
problem continues, report the problem to your system administrator.  
Unable to locate file filename.  
Explanation: TSM cannot locate the specified file.  
System Action: Processing continues.  
User Response: Verify that TSM was installed and configured correctly. If the  
problem continues, report the problem to your system administrator.  
Backing up/Archiving drives with duplicate volume labels is not allowed.  
Explanation: You tried to back up or archive a drive that has a duplicate volume  
label. Because TSM uses the volume label to keep track of backup/archive  
information, it cannot back up or archive files from a drive with a duplicate volume  
label.  
System Action: TSM cannot select the drive.  
User Response: If the volume needs to be available to the system, exit TSM, and  
assign a volume label to the drive. Restart TSM and retry the operation.  
ANS5165E  
Drive has no volume label.Backup/Archive not allowed.  
Explanation: You tried to backup or archive a drive that has no volume label.  
System Action: TSM rejected the selected drive.  
User Response: If the drive is a floppy drive, place a disk with a volume label in  
it and retry the operation. If the disk is a hard drive, ensure the drive has a volume  
label, and retry the operation.  
Tivoli Storage Manager Messages  
1219  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5166E  
ANS5169E  
An error occurred saving the registry key  
Explanation: The active registry key cannot be saved.  
System Action: Registry backup operation terminates.  
User Response: See your system administrator.  
The destination path must contain a drive letter  
Explanation: The entered path must begin with a drive letter, colon, and root  
slash.  
System Action: TSM did not continue with the requested operation.  
User Response: Enter the destination path in the correct format.  
ANS5173E  
An error occurred accessing NTFS security information.  
Explanation: An error occurred while attempting to access NTFS security  
information.  
System Action: Object will not be processed.  
User Response: See your system administrator or bypass by using SkipNTSecurity  
option.  
ANS5174E  
ANS5176E  
ANS5177E  
ANS5178E  
A required NT privilege is not held.  
Explanation: The user account running TSM does not possess a required NT user  
right/privilege for performing the current operation.  
System Action: Object will not be processed.  
User Response: See your system administrator.  
Exporting RSM database files failed. No files will be backed up.  
Explanation: An error occurred while exporting the RSM database files. The  
database will not be backed up.  
System Action: Processing stopped.  
User Response: Ask your system administrator to check the error log.  
Importing RSM database files failed. No changes will be in effect.  
Explanation: An error occurred while importing the RSM database files. The  
database will not be updated.  
System Action: Processing stopped.  
User Response: Ask your system administrator to check the error log.  
Restart of the RSM service failed. Restart the RSM service manually.  
Explanation: RSM database files have been restored from the TSM server and  
imported. TSM has tried to restart the RSM service on the user’s behalf but has run  
into a problem.  
System Action: Processing stopped.  
User Response: Restart the RSM service manually.  
1220  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5179E  
ANS5181E  
Restoring a volume mount point to a non-empty directory.  
Explanation: You are trying to restore a volume mount point to a non-empty  
directory which is not allowed. Volume mount point is not restored.  
System Action: Processing continues.  
User Response: None.  
Invalid selection; A specific backup set must be selected.  
Explanation: A selection was made that might result in multiple backup sets being  
restored at the same time, but restoring multiple backup sets at the same time is not  
supported.  
System Action: The backup set restore was not performed.  
User Response: Select a specific backup set to be restored.  
ANS5182E  
ANS5183W  
ANS5187E  
ANS5188E  
ANS5189E  
Multiple backup sets can not be restored at the same time.  
Explanation: Multiple backup sets were selected to be restored, but restoring  
multiple backup sets at the same time is not supported.  
System Action: The backup set restore was not performed.  
User Response: Select a specific backup set to be restored.  
Objects of different types cannot be restored at the same time.  
Explanation: Restoring objects of different types is not allowed. For example,  
restoring Backup Sets and regular file objects at the same time is not possible.  
System Action: No processing takes place.  
User Response: Select objects of the same type to perform restore operation.  
Unable to set SHAREAS extended attribute for file: ’pathname’ Return code:  
returncode’ ’strerror’ Reason code: ’reasoncode’  
Explanation: You must be the file owner or have superuser authority.  
System Action: File processed without setting attribute.  
User Response: The attribute must be set manually.  
Unable to clear SHAREAS extended attribute for file: ’pathname’ Return code:  
returncode’ ’strerror’ Reason code: ’reasoncode’  
Explanation: You must be the file owner or have superuser authority.  
System Action: File processed without setting attribute.  
User Response: The attribute must be set manually.  
Unable to set APF extended attribute for file: ’pathname’ Return code:  
returncode’ ’strerror’ Reason code: ’reasoncode’  
Explanation: You must have at least READ access to the BPX.FILEATTR.APF  
facility class profile and you must be the file owner or have superuser authority.  
System Action: File processed without setting attribute.  
Tivoli Storage Manager Messages  
1221  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The attribute must be set manually.  
ANS5190E  
Unable to set PROGCTL extended attribute for file: ’pathname’ Return code:  
returncode’ ’strerror’ Reason code: ’reasoncode’  
Explanation: You must have at least READ access to the  
BPX.FILEATTR.PROGCTL facility class profile and you must be the file owner or  
have superuser authority.  
System Action: File processed without setting attribute.  
User Response: The attribute must be set manually.  
ANS5191E  
ANS5192E  
NT Active Directory is not online. Offline backup is not supported.  
Explanation: NT Active Directory is not online when performing a backup  
operation. Offline backup is not supported.  
System Action: Processing stopped.  
User Response: Reboot computer and turn on Active Directory, and try the  
operation again.  
NT Active Directory is online. Online restore is not supported.  
Explanation: NT Active Directory is online when performing a restore operation.  
Online restore is not supported.  
System Action: Processing stopped.  
User Response: Reboot computer and enter Active Directory repair mode, then try  
the operation again.  
ANS5193E  
ANS5194E  
ANS5197E  
Certificate Services is not online. Offline backup is not supported.  
Explanation: Certificate Services is not online when performing a backup  
operation. Offline backup is not supported.  
System Action: Processing stopped.  
User Response: Start Certificate Services and try the operation again.  
Certificate Services is online. Online restore is not supported.  
Explanation: Certificate Services is online when performing a restore operation.  
Online restore is not supported.  
System Action: Processing stopped.  
User Response: Stop Certificate Services and try the operation again.  
File Replication Service backup failed.  
Explanation: Tivoli Storage Manager encountered an error while backing up files  
under control of the Windows 2000 File Replication Service  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the File Replication Service is operating properly. Restart the service and  
retry the backup operation.  
1222  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5198E  
File Replication Service restore failed.  
Explanation: Tivoli Storage Manager encountered an error while restoring files  
under control of the Windows 2000 File Replication Service  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the File Replication Service is operating properly. Restart the service and  
retry the restore operation.  
ANS5200E  
ANS5201E  
ANS5202E  
ANS5203E  
ANS5204E  
ANS5205E  
ANS5206E  
The specified system object is only valid on Windows NT  
Explanation: The specified system object type is only valid on Windows NT.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
The specified function is not implemented  
Explanation: The specified function is not implemented.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error occurred creating the registry staging directory  
Explanation: An error occurred creating the registry staging directory.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error saving one or more registry keys  
Explanation: An error occurred saving one or more registry keys.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error occurred creating the eventlog staging directory  
Explanation: An error occurred creating the eventlog staging directory.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error saving one or more eventlogs  
Explanation: An error occurred saving one or more eventlogs.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
An error replacing one or more registry keys  
Explanation: An error occurred replacing one or more registry keys.  
System Action: Processing stopped.  
User Response: Correct the command and retry the operation.  
Tivoli Storage Manager Messages  
1223  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS5207I  
ANS5208E  
The machine must be rebooted for the changes to take effect  
Explanation: The machine must be started for the changes to take effect.  
System Action: TSM backed up the files.  
User Response: Reboot the machine  
An invalid date was entered.  
Explanation: An invalid date value was entered. Either the syntax of the value  
was not correct, or an actual value (for example, “45” for month) was invalid.  
System Action: Processing stops.  
User Response: Identify and correct the invalid date value. Refer to the user’s  
guide of the corresponding platform for the correct date syntax.  
ANS5209E  
System Volume backup failed.  
Explanation: Tivoli Storage Manager encountered an error while backing up files  
of the Windows 2000 System Volume  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the system volume was successfully initialized. Restart the service and retry  
the backup operation  
ANS5210E  
System Volume restore failed.  
Explanation: Tivoli Storage Manager encountered an error while restoring files of  
the Windows 2000 System Volume  
System Action: Processing stopped.  
User Response: Examine the Windows 2000 File Replication Service Event log to  
insure the system volume was successfully initialized. Restart the service and retry  
the restore operation.  
ANS24314T  
ANS24315T  
ANS24316T  
Back up all network filesystems  
Back up all automounted Loopback Virtual File systems  
Back up all automounted network file systems  
1224  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Macintosh Backup-Archive Client  
(6000–6999)  
ANS6001S  
NULL character found in the name of folder/file filename.  
Explanation: A NULL character was found in the name of a file or folder. Some  
products place a NULL character in a file name so that the file is sorted  
alphabetically to the top of a list. TSM cannot backup/restore such files.  
System Action: TSM cannot complete the requested operation.  
User Response: Remove the NULL character by renaming the file or folder.  
Tivoli Storage Manager Messages  
1225  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1226  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Windows Backup-Archive Client  
(7000–7999)  
ANS7503W  
ANS7504W  
ANS7505W  
ANS7506W  
ANS7507W  
Invalid drive entry  
Explanation: An invalid entry is entered on the Drive field.  
System Action: TSM prompts you to enter a valid drive letter.  
User Response: Enter a valid drive letter or see your system administrator for the  
correct syntax.  
Invalid directory entry  
Explanation: An invalid entry is entered on the Directory field.  
System Action: TSM prompts you to enter a valid directory.  
User Response: Enter a valid directory or see your system administrator for the  
correct syntax.  
Invalid filename entry  
Explanation: An invalid entry is entered on the Filename field.  
System Action: TSM prompts you to enter a valid file name.  
User Response: Enter a valid file name or see your system administrator for the  
correct syntax.  
Invalid label entry  
Explanation: An invalid entry is entered on the Label field.  
System Action: TSM prompts you to enter a valid volume label.  
User Response: Enter a valid volume label or see your system administrator for  
correct syntax.  
Invalid node entry  
Explanation: An invalid entry is entered on the Node Name field.  
System Action: TSM prompts you to enter a valid node name.  
Tivoli Storage Manager Messages  
1227  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User Response: Enter a valid node name or see your system administrator for the  
correct syntax.  
ANS7508W  
ANS7509W  
ANS7521E  
Duplicate authorization  
Explanation: The authorization rule entered by the user is already defined.  
Duplicate rules are not allowed.  
System Action: TSM allows you to enter a different rule.  
User Response: Enter an authorization rule that has not been defined yet or cancel  
defining authorization rules.  
Drive and/or volume label do not exist  
Explanation: Either the drive or the volume label or both do not match the  
existing ones. Rules must be defined on existing drives and volumes.  
System Action: TSM prompts you to reenter drives and/or volumes or cancel  
defining authorization rules.  
User Response: Enter an existing drive and volume to define the desire rule.  
Error Loading WINSOCK.DLL - not in Search Path  
Explanation: TSM cannot find the Windows Socket support file  
(WINSOCK.DLL) in the current search path. This message only applies when using  
TCP/IP communications.  
System Action: Connection to server fails.  
User Response: Shut down Windows and place the directory where this file  
resides in the DOS path statement.  
ANS7524E  
Error Loading WINSOCK.DLL  
Explanation: Error loading the Windows socket support file into memory. This  
error only applies when using TCP/IP communications.  
System Action: Connection to server fails.  
User Response: Because this error is caused by insufficient memory, shut down  
running applications and retry. If the problem persists, see your system  
administrator.  
ANS7525E  
Error Loading Function(s) from WINSOCK.DLL  
Explanation: Error loading one or more functions from the Windows socket  
support file.  
System Action: Connection to server fails.  
User Response: Since this might possibly be caused by insufficient memory, shut  
down running applications and retry. If the problem persists, see your system  
administrator.  
1228  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS7551E  
ANS7555E  
The source path cannot contain a drive letter  
Explanation: The entered path cannot contain a drive letter.  
System Action: TSM did not continue with the requested operation.  
User Response: Enter the source path in the correct format.  
The destination path must contain a drive letter  
Explanation: The entered path must begin with a drive letter, colon, and root  
slash.  
System Action: TSM did not continue with the requested operation.  
User Response: Enter the destination path in the correct format.  
ANS7556E  
ANS7560E  
An invalid drive letter was entered  
Explanation: You entered an invalid drive letter.  
System Action: TSM prompts you for the correct drive ID.  
User Response: Reenter the drive ID in the correct format.  
Drive drive-name has no volume label. Backup/Archive not allowed.  
Explanation: The specified drive-name selected cannot be backed up.  
System Action: TSM rejected the selected drive.  
User Response: If the drive is a floppy drive, place a disk with a volume label in  
it and retry the operation. If the disk is a hard drive, ensure the drive has a volume  
label, and retry the operation.  
ANS7561E  
ANS7564E  
Drive drive-name is unavailable  
Explanation: In an attempt to process a file, the specified drive-name was found  
unavailable.  
System Action: TSM did not process the file.  
User Response: Determine why the drive was not available, make it ready, and  
retry the operation.  
Backing up/Archiving drives with duplicate volume labels is not allowed.  
Explanation: You tried to back up or archive a drive that has a duplicate volume  
label. Because TSM uses the volume label to keep track of backup/archive  
information, it cannot back up or archive files from a drive with a duplicate volume  
label.  
System Action: TSM cannot select the drive.  
User Response: If the volume needs to be available to the system, exit TSM, and  
assign a volume label to the drive. Restart TSM and retry the operation.  
ANS7641E  
Registry Backup failed  
Explanation: TSM An error occurred while backing up the registry.  
System Action: Registry backup function fails.  
Tivoli Storage Manager Messages  
1229  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: See you system administrator.  
ANS7642E  
An Error occurred creating the registry directory structure  
Explanation: An error occurred while creating the directory structure to  
save/replace registry key.  
System Action: Registry function fails.  
User Response: See you system administrator.  
ANS7643E  
ANS7650E  
An error occurred saving the registry key  
Explanation: The active registry key cannot be saved.  
System Action: Registry backup operation terminates.  
User Response: See your system administrator.  
An error occurred replacing the registry key  
Explanation: The backed up registry key(s) were restored from the server but  
cannot be made active into the registry.  
System Action: Current Registry key remains active.  
User Response: See your system administrator.  
ANS7660E  
ANS7701E  
ANS7730E  
ANS7731E  
Registry activation failed  
Explanation: An error occurred while restoring the registry key from the server.  
System Action: Registry restore function fails.  
User Response: See your system administrator.  
Create directory failed  
Explanation: The specified new directory cannot be created.  
System Action: Specify another directory name.  
User Response: See your system administrator.  
Event Log Backup failed  
Explanation: An error occurred while backing up the event logs.  
System Action: Event log backup function fails.  
User Response: See your system administrator.  
Event Log Restore failed  
Explanation: An error occurred while restoring the event logs from the server.  
System Action: Event Log restore function fails.  
User Response: See your system administrator.  
1230  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS7732E  
An Error occurred creating the event log directory structure  
Explanation: An error occurred while creating the directory structure to save the  
event logs.  
System Action: Event Log function fails.  
User Response: See your system administrator.  
Tivoli Storage Manager Messages  
1231  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1232  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Administrative Command Line  
Client (8000–8499)  
ANS8000I  
Server command: ’command’  
Explanation: The specified command is being sent to the server. This message is  
displayed when the command is generated from a macro or when the client is  
running in batch mode.  
System Action: The command is sent to the server for processing.  
User Response: None.  
ANS8001I  
Return code return code value.  
Explanation: The error code shown has been returned from the preceding server  
command. This message is preceded by a server message explaining the reason for  
the error code.  
System Action: None.  
User Response: None.  
ANS8002I  
ANS8003I  
Highest return code was return code value.  
Explanation: At exit from the client, the highest return code encountered during  
the session is displayed.  
System Action: This value is used as the program exit code.  
User Response: None.  
Process number process ID started.  
Explanation: As a result of the preceding server command, the process whose ID  
is shown starts to execute the command. The process can be monitored using the  
QUERY PROCESS command.  
System Action: None.  
User Response: None.  
Tivoli Storage Manager Messages  
1233  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS8008W  
ANS8009E  
ANS8010E  
Redirection inside macro whose output is redirected is ignored.  
Explanation: An output redirection symbol has been encountered inside a macro.  
However, the output of the macro itself (or a higher level macro) is already being  
redirected.  
System Action: The redirection request is ignored.  
User Response: None.  
Exiting due to command or option errors.  
Explanation: Because of errors in command line or option file parameters  
displayed earlier, the administrative client session is ending.  
System Action: The client exits.  
User Response: Fix the option file parameter in error and restart the client, or  
restart the client with proper command line parameters.  
File ’file spec’ not found.  
Explanation: The client options file cannot be found, either in the current  
directory or in the directory specified by the DSM_DIR environment variable.  
System Action: The client cannot process the options file.  
User Response: Locate the client options file, or create the file if one does not  
exist.  
ANS8011E  
ANS8012E  
ANS8013E  
File ’file spec’, line line number, value ’keyword’ is not a valid keyword.  
Explanation: The client encounters an incorrect keyword in the client options file.  
System Action: The keyword is ignored.  
User Response: Correct the keyword in the client options file and restart the  
administrative client.  
Option processing storage exhausted.  
Explanation: During processing of the client options file, the client runs out of  
memory.  
System Action: The client session is ended.  
User Response: Make more memory available and restart the administrative client.  
File ’filespec’, line line number, value ’pattern’ is too complex a pattern.  
Explanation: The include or exclude pattern issued is too complex to be  
accurately interpreted by the client.  
System Action: The include/exclude statement is ignored.  
User Response: Correct the syntax for the pattern.  
1234  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8014E  
Insufficient information to connect to host.  
Explanation: The client options file or command line, or both, do not contain  
enough communications information to successfully connect to the server system.  
For example, with TCP/IP both the TCPPort number and TCPServer address are  
required to make a connection.  
System Action: The administrative client session is ended.  
User Response: Determine what information is needed to establish a connection  
for your communications method and then specify all that information in your client  
options file or on the administrative client command line.  
ANS8015E  
File ’file spec’, error code error code from options processing.  
Explanation: An unknown error code is returned from the routine that processes  
the client options file.  
System Action: The administrative client session is ended.  
User Response: Attempt to determine the error and correct it. If the problem  
persists, contact your service representative.  
ANS8016E  
ANS8017E  
ANS8018E  
ANS8019E  
Command line parameter parameter number: ’parameter’ is too long.  
Explanation: The specified command line parameter exceeds the maximum length  
for a command line parameter.  
System Action: The administrative client session is ended.  
User Response: Reissue the command with a shorter parameter.  
Command line parameter parameter number: ’parameter’ is not valid.  
Explanation: The command line parameter shown is not a valid administrative  
client parameter.  
System Action: The administrative client session is ended.  
User Response: Reissue the command with valid parameters.  
Administrative command not valid in Console mode.  
Explanation: The Console Mode option has been specified but the client  
encounters what appears to be a server command on the command line.  
System Action: The administrative client session is ended.  
User Response: Reissue the command with no server command.  
Id and password must be supplied in Batch mode.  
Explanation: A server command has been encountered on the command line, but  
no administrator ID or password, or both, are specified.  
System Action: The administrative client session is ended.  
User Response: Reissue the command and include the -ID and -PASSWORD  
parameters on the command line.  
Tivoli Storage Manager Messages  
1235  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8020E  
ANS8021E  
Unable to open file ’file spec’ for output.  
Explanation: The file name specified in the -OUTFILE option cannot be opened.  
System Action: The -OUTFILE parameter is ignored.  
User Response: Allow processing to continue or exit the session and correct the  
file name.  
Exiting Batch mode session due to output file error.  
Explanation: The file specified in the -OUTFILE parameter cannot be opened for  
a session running in Batch mode.  
System Action: The administrative client session is ended.  
User Response: Reissue the command with a valid output file name or make  
space available for the output file.  
ANS8022E  
Output will be written only to stdout.  
Explanation: The file specified in the -OUTFILE parameter cannot be opened, so  
output is written only to the standard output stream.  
System Action: Output that would have been written to the output file is written to  
the standard output stream.  
User Response: Allow processing to continue or exit the session and correct the  
file name.  
ANS8023E  
Unable to establish session with server.  
Explanation: The administrative client cannot start a session with the requested  
server. This message is preceded by another message that explains the reason for the  
error.  
System Action: The administrative client session is ended.  
User Response: Attempt to correct the error. If the problem persists, contact your  
service representative.  
ANS8024E  
ANS8025E  
End of macro after continued command line.  
Explanation: A macro containing a continuation line has been executed, but no  
more lines are found in the macro file.  
System Action: The continued command is ignored, and an error return code is set  
for the macro.  
User Response: Correct the macro in error.  
I/O Error reading command input.  
Explanation: The client is unable to read an input command from the terminal.  
System Action: The administrative client session is ended.  
User Response: Correct the problem on the terminal and retry the administrative  
session.  
1236  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8026E  
Input line longer than maximum of max length characters. Use continuation.  
Explanation: An input command line is longer than the maximum input line  
length allowed.  
System Action: The input command is ignored.  
User Response: Reissue the command with several lines using continuation  
characters.  
ANS8027E  
ANS8028E  
Unterminated comment in command.  
Explanation: An input command contains an opening comment mark but no  
closing comment mark.  
System Action: The input command is ignored.  
User Response: Reissue the command with matching comment marks.  
Command longer than maximum of max length characters.  
Explanation: An input command longer than the maximum command length  
allowed has been entered.  
System Action: The input command is ignored.  
User Response: Reissue the command with fewer characters. This could mean  
replacing series of repeating blanks with a single blank.  
ANS8029E  
Macro processing terminated.  
Explanation: An error occurs during processing of a macro because the  
-ITEMCOMMIT option is not specified on the command line. Processing of this  
macro and any higher level macro is terminated.  
System Action: All current macro processing ends.  
User Response: Specify the -ITEMCOMMIT option on the command line to  
ensure that the server commits each command in the macro individually.  
ANS8030E  
ANS8031E  
Substituted command longer than maximum of max length characters.  
Explanation: After variable substitution, an input command is longer than the  
maximum command length allowed.  
System Action: The input command is ignored.  
User Response: Reissue the command with fewer characters. This may require  
replacing a series of repeating blanks with a single blank.  
Missing name of macro to execute.  
Explanation: A macro command is encountered that does not contain a macro  
name.  
System Action: The command is ignored.  
User Response: Reissue the macro command with a macro file name.  
Tivoli Storage Manager Messages  
1237  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8032E  
Could not allocate storage to process macro ’file spec’.  
Explanation: The client cannot allocate enough memory to process the macro  
shown.  
System Action: The macro is ignored and an error is returned.  
User Response: Make more memory available to the client and retry the macro  
command.  
ANS8033E  
ANS8034E  
Unable to handle type output type output.  
Explanation: An internal processing error occurs.  
System Action: Output from the prior command is incomplete.  
User Response: Contact your service representative.  
Your administrator ID is not recognized by this server.  
Explanation: The administrator ID entered is not known to the requested server.  
System Action: The administrative session terminates.  
User Response: Ensure that you are using a registered administrative ID for the  
server to which you are connecting.  
ANS8035E  
ANS8036E  
ANS8037E  
ANS8038E  
Interrupted by user.  
Explanation: During an administrative session, a keyboard interrupt or break  
sequence is entered.  
System Action: The administrative session is terminated.  
User Response: Restart the administrative client session.  
Administrative command not valid in Mount mode.  
Explanation: The Mount Mode option has been specified but the client encounters  
what appears to be a server command on the command line.  
System Action: The administrative client session is ended.  
User Response: Reissue the command with no server command.  
Missing name for redirection file.  
Explanation: A command is entered that contains an output redirection symbol but  
no output file name.  
System Action: The command is ignored and an error is returned.  
User Response: Reissue the command with an output file name.  
Unable to open file ’file spec’ for redirection.  
Explanation: A command has been entered that specifies an output redirection  
file, but the file cannot be opened.  
System Action: The command is ignored and an error is returned.  
User Response: Reissue the command with a valid output file name or make  
space available for the output file.  
1238  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8039E  
ANS8040E  
ANS8041E  
SVM is at level version.release.level, DSADM requires at least 2.5.-2, unable to  
continue.  
Explanation: A down-level version of SVM is being used with the administrative  
client.  
System Action: The client session is ended.  
User Response: Obtain a more recent version of SVM.  
C library not available, unable to continue.  
Explanation: The C/370 run-time library is not available for use by the  
administrative client.  
System Action: The client session is ended.  
User Response: Get access to the C/370 run-time library and then retry the  
command.  
The server connection has been lost and cannot be re-established.  
Explanation: During an administrative session, the client discovers that the  
connection with the server has been severed; an attempt to reestablish the  
connection fails.  
System Action: The client session is ended.  
User Response: Determine the cause of the failure; then try to restart the session  
at a later time. If the problem persists, contact your service representative.  
ANS8042E  
ANS8045E  
Update password canceled by user.  
Explanation: Entry of a new password is canceled.  
System Action: The password is not updated.  
User Response: None.  
Communications error.  
Explanation: An unexpected communications error occurs during an  
administrative session.  
System Action: The client session is ended.  
User Response: Verify that communications are active between the client and  
server machines. Server outages, processor outages, and communication controller  
outages can cause this error.  
ANS8046E  
System failure.  
Explanation: The client connection with the server has terminated due to a system  
error.  
System Action: The client session is ended.  
User Response: Contact your service representative.  
Tivoli Storage Manager Messages  
1239  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8047E  
ANS8049E  
Buffer overflow.  
Explanation: A communications buffer overflow occurs.  
System Action: The client session is ended.  
User Response: Retry the operation. If the problem persists, contact your service  
representative.  
Connection timed out.  
Explanation: The connection to the server cannot be established.  
System Action: The client session is ended.  
User Response: Check for a networking problem. If the problem persists, contact  
your service representative.  
ANS8050E  
ANS8051E  
Session rejected: SNALU6.2 connection failure. CPIC unknown error occurred.  
Explanation: An unexpected CPI Communication error occurs.  
System Action: Processing stops.  
User Response: Contact your service representative.  
IUCV communication error.  
Explanation: An IUCV communications send/receive error occurs.  
System Action: The client session is ended.  
User Response: Retry the administrative session. If the problem persists, contact  
your service representative.  
ANS8052E  
IUCV connection failure.  
Explanation: The administrative client is unable to establish an IUCV connection  
to the server.  
System Action: The client session is ended.  
User Response: Retry the administrative session. If the problem persists, contact  
your service representative.  
ANS8053E  
ANS8054E  
Network cannot be accessed.  
Explanation: An error occurs accessing the network.  
System Action: The client session is ended.  
User Response: Retry the administrative session. If the problem persists, contact  
your service representative.  
No memory available to service request.  
Explanation: Sufficient server memory is not available.  
System Action: The client session is ended.  
User Response: Retry the administrative session. If the problem persists, contact  
your service representative.  
1240  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8055E  
ANS8056E  
ANS8057E  
ANS8058E  
No server resources available.  
Explanation: Sufficient server resources are not available.  
System Action: The client session is ended.  
User Response: Retry the administrative session. If the problem persists, contact  
your service representative.  
Your administrator ID is locked.  
Explanation: The administrative ID entered has been locked by a system  
administrator and cannot be used.  
System Action: The client session is ended.  
User Response: Contact your system administrator to unlock your ID.  
The requested language files are not available.  
Explanation: The NLS repository for the language specified is not available.  
System Action: The client session is ended.  
User Response: Use a different language or obtain a copy of the NLS repository  
for the language desired.  
Error loading one or more functions from SYS1.CSSLIB.  
Explanation: TSM cannot load the required CPI Communication functions. This  
message only applies when using SNALU6.2 communications on MVS 4.2.0 or  
4.2.2.  
System Action: The connection to the server fails.  
User Response: Before retrying the operation, ensure that APAR OY52924 has  
been applied (PTF UY79385 for MVS 4.2.0, PTF UY79386 for MVS 4.2.2). Also,  
ensure that SYS1.CSSLIB is either STEPLIBed or added to LINKLIST. As an  
alternative to applying the APAR, an installation may choose to link-edit the TSM  
TSO administrative client again, including the module ATBPBI from SYS1.CSSLIB.  
ANS8059E  
The TCP/IP functions have not been linked into this module.  
Explanation: The ADSM TSO administrative client cannot find the TCP/IP  
functions required to support TCP/IP communications.  
System Action: The connection to the server fails.  
User Response: The TCP/IP functions must be included in the  
DSMADMC/ANSADM module. Refer to the Program Directory for this product for  
instructions on how to include the TCP/IP functions in the DSMADMC/ANSADM  
module.  
ANS8060E  
The IUCV DECLARE BUFFER has failed. IUCV functions may not be  
available.  
Explanation: TSM fails trying to start IUCV communications.  
System Action: The connection to the server fails.  
Tivoli Storage Manager Messages  
1241  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Because IUCV support comes with TCP/IP, ensure that TCP/IP is  
properly installed, and retry the operation.  
ANS8061E  
Session Rejected: The server does not allow a signon as a Unicode enabled  
administrative client  
Explanation: The administrative client is unable to establish a connection to the  
server because of a unicode enabling mismatch between server and client.  
System Action: The client session is ended.  
User Response: Register a new administrator from a different administrative client  
or the server console, and signon with the new administrator ID.  
ANS8062E  
Error loading the SNA Services/6000 CPIC routines.  
Explanation: TSM cannot load the SNA Services/6000 driver file. This message  
only applies when using CPI Communications via SNA Services/6000.  
System Action: The connection to the server fails.  
User Response: Make sure the SNA Services/6000 CPI Communications library  
file, '/usr/lib/libcpic.a' exists. This file should have been installed when SNA  
Services/6000 was installed. Also, make sure the TSM SNA Services/6000 driver  
file, dsmsna.drv, exists in the TSM installation directory.  
ANS8063E  
ANS8064E  
ANS8494E  
APPC insufficient memory.  
Explanation: Sufficient memory is not available to perform the requested APPC  
function.  
System Action: Processing stops.  
User Response: Shutdown running applications and retry the operation. If the  
problem persists, contact your service representative.  
Communication timeout. Reissue the command.  
Explanation: The connection to the server is ended because of a communication  
timeout from the server.  
System Action: The server does not process the command.  
User Response: Reissue the command. If necessary, increase the values of  
IDLETIMEOUT and COMMTIMEOUT options in the server options file.  
Error during buffer operation (file name:line number) error code: error code  
Explanation: Error occurs when doing the following operations: 1. Creating input  
buffer. 2. Retrieving data from buffer. 3. Retrieving the pointer to field data. 4.  
Clearing input buffer. 5. Deleting input buffer.  
System Action: The administrative client session ends.  
User Response: Contact your service representative.  
1242  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS8495E  
ANS8496E  
Error while writing data (file name:line number) error Code: error code  
Explanation: An error occurs while writing data to the session.  
System Action: The administrative client session ends.  
User Response: Contact your service representative.  
Error during session operation (file name:line number) error code: error code  
Explanation: An error occurs during one of the following operations: 1.  
Retrieving session description. 2. Initializing session description. 3. Initializing  
window description. 4. Creating the session. 5. Writing title to the display. 6.  
Writing prompt to the display.  
System Action: The administrative client session ends.  
User Response: Contact your service representative.  
ANS8497E  
ANS8498E  
ANS8499E  
Get time operation failed (file name:line number) error code: error code  
Explanation: An error occurs when getting system time.  
System Action: The administrative client session ends.  
User Response: Contact your service representative.  
Get job information failed (file name:line number) error code: error code  
Explanation: An error occurs while getting job information.  
System Action: The administrative client session ends.  
User Response: Contact your service representative.  
Error occurs when sending messages (file name:line number) error code: error  
code  
Explanation: An error occurs when invoking the sending message api.  
System Action: The administrative client continues.  
User Response: None.  
Tivoli Storage Manager Messages  
1243  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1244  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Tivoli Space Manager  
(9000–9999)  
ANS9003E  
program-name: file system for path-name is not in the dsmmigfstab file.  
Explanation: TSM cannot find the file system in the dsmmigfstab file.  
System Action: TSM cannot complete the requested operation.  
User Response: Ensure that the file system is both valid and local, and that it is  
an FSM file system.  
ANS9004E  
program-name: cannot update file-system because it is not an FSM file system.  
Explanation: The program cannot find the file system in the dsmmigfstab file. The  
update failed.  
System Action: TSM cannot complete the requested operation.  
User Response: The file system cannot be updated because it is not an FSM file  
system. You must first add space management to the file system before you can  
update space management settings for the file system.  
ANS9007E  
ANS9008W  
error-program: error occurred. Run ’dsmreconcile file-system’  
Explanation: An error occurred.  
System Action: TSM terminates the operation.  
User Response: Run the operation specified.  
program-name: cannot mix -a and named file systems.  
Explanation: You have used the -a option (which tells TSM to work on all of the  
local file systems), as well as one or more named file systems.  
Tivoli Storage Manager Messages  
1245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
System Action: TSM terminates the operation.  
User Response: Enter the command again, using either the -a option, or the name  
of one or more file systems, but not both.  
ANS9009W  
program-name: no file system specified.  
Explanation: You did not include the name of a file system as part of the  
argument to this command.  
System Action: TSM terminates the operation.  
User Response: Enter the command again, including the name of one or more file  
systems.  
ANS9012E  
ANS9016E  
error-program: Command must be run by root user.  
Explanation: TSM requires that a root user perform this operation.  
System Action: TSM terminates the operation.  
User Response: Change to root user, and then retry the operation.  
Cannot get space management migration status for path.  
Explanation: An error occurred while trying to get the space management  
migration status. Either the permissions for the status file are not set correctly, or  
the status file is damaged.  
System Action: TSM terminates the operation.  
User Response: The root user should check the permissions of the status file, or  
contact the service representative.  
ANS9017W  
error-program: Minimum number of recall daemons min-dsmrecalld cannot be  
greater than maximum number of recall daemons max-dsmrecalld; defaulting to  
minimum min-dsmrecalld and maximum max-dsmrecalld.  
Explanation: A minimum number of recall daemons has been entered that is  
greater than the maximum number of recall daemons.  
System Action: TSM uses defaults instead of the values specified in the client  
system options file (dsm.sys).  
User Response: Correct the MINRECALLDAEMONS and  
MAXRECALLDAEMONS options in the client system options file and retry the  
operation.  
1246  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9018W  
program-name: option option value value invalid, range min-value to max-value.  
Explanation: An invalid value has been entered. Value should be in the range  
specified by the message.  
System Action: TSM uses defaults instead of the value specified by the user.  
User Response: Correct the invalid input value.  
ANS9019W  
ANS9020I  
ANS9021E  
program-name: unable to parse option value ’argument’  
Explanation: Input is incorrect or is not in correct format.  
System Action: TSM continues.  
User Response: Retry operation with correct usage syntax.  
program-name: dispatching a subsidiary recall daemon slave-ID ...  
Explanation: The master recall daemon is starting a subsidiary recall daemon.  
System Action: TSM continues.  
User Response: Continue.  
error-program Unknown recall daemon (pid process-ID) terminated abnormally,  
status: status.  
Explanation: A recall daemon is terminated abnormally.  
System Action: TSM terminates the operation.  
User Response: Retry operation. If problem persists, contact your service  
representative.  
ANS9022E  
error-program Recall daemon (pid process-ID) terminated abnormally, status:  
status.  
Explanation: A recall daemon is terminated abnormally.  
System Action: TSM terminates the operation.  
User Response: Retry operation. If problem persists, contact your service  
representative.  
ANS9023I  
error-program: Subsidiary recall daemon process exiting.  
Explanation: The process is interrupted and exiting. The user has terminated the  
process.  
Tivoli Storage Manager Messages  
1247  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM detected an interrupt. The recall daemon is terminated and  
exiting.  
User Response: None.  
ANS9025W  
program-name: cannot truncate inode inode-number on file system  
(file-system-ID, file-system-ID): error.  
Explanation: TSM cannot truncate the file to its correct stub file size. The file  
remains one full block in size.  
System Action: TSM continues.  
User Response: Retry the operation. If error persists, reboot the system. If error  
still persists, contact your service representative.  
ANS9026E  
program-name: no space for file (block-count) (free-blocks) in file system  
file-system.  
Explanation: TSM does not have enough space in the file system to perform  
recall.  
System Action: TSM cannot complete the requested operation.  
User Response: Free some space in the file system and retry the operation.  
ANS9028E  
program-name: cannot determine the file system name for fsid (file-system-ID,  
file-system-ID).  
Explanation: TSM is unable to determine the name of the file system with the  
specified file-system-id.  
System Action: TSM is unable to recall the requested file.  
User Response: Determine if the file system which contains the file has an entry  
in /etc/adsm/SpaceMan/config/dsmmigfstab. Typically this problem should not occur  
unless the dsmmigfstab file was manually updated after the file system was  
mounted, and the entry was either removed or commented out. Once the entry is  
added back to dsmmigfstab, try the file recall again.  
ANS9029E  
error-program: cannot store information into database, error: error.  
Explanation: TSM is unable to store the premigration information into its  
database.  
System Action: TSM continues.  
User Response: None.  
1248  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9030W  
Cannot set conflicting attributes to file file-name.  
Explanation: TSM cannot set the file attributes because the requested attributes  
are in conflict with one another.  
System Action: TSM does not set the file attributes.  
User Response: Retry this operation with attributes that do not conflict with each  
other.  
ANS9031W  
File file-name is not a migrated file.  
Explanation: TSM can only set file attributes to a migrated file. This file has not  
been migrated.  
System Action: TSM does not set the file attributes.  
User Response: Migrate this file, and then retry the operation.  
ANS9032W  
File file-name is not in an FSM file system.  
Explanation: TSM detects that the file is not in an FSM file system, and  
therefore, it cannot perform the operation requested.  
System Action: TSM does not set the file attributes.  
User Response: Add space management to the file system, migrate the file, and  
then retry the operation.  
ANS9036W  
program-name: migrated file(s) are missing on server for number stub file(s).  
Look in ’file-spec’ for file names.  
Explanation: TSM cannot find the migrated file(s) on the server.  
System Action: TSM continues.  
User Response: Look in the path mentioned in the message for the file name. Also  
ensure that you are working with the correct server for this file.  
ANS9054E  
error-program: cannot set specified execution mode: error.  
Explanation: TSM cannot set the execution mode successfully.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem persists, contact your service  
representative.  
Tivoli Storage Manager Messages  
1249  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9057W  
ANS9058E  
error-program: cannot get space information for file-system: error.  
Explanation: TSM cannot get the space information for the file system.  
System Action: TSM continues.  
User Response: Verify that space management has been added to the file system.  
error-program: cannot close file-spec: error.  
Explanation: TSM cannot close the file.  
System Action: TSM terminates the current operation.  
User Response: Retry the operation. If problem persists, contact your system  
administrator.  
ANS9059E  
ANS9060W  
error-program: process cannot detach to become a daemon.  
Explanation: TSM process cannot detach itself to become a daemon.  
System Action: TSM cannot start the daemon as requested. TSM stops.  
User Response: Retry the operation.  
error-program: cannot get and increase limit of open files.  
Explanation: TSM either cannot get the limit of the number of open files, or  
cannot increase the limit of the number of open files.  
System Action: TSM cannot increase the number of open files, and was not able  
to complete the operation.  
User Response: Free some file space by ending some processes or removing some  
files, and retry the operation.  
ANS9061E  
program-name: directory-spec: not a writable directory.  
Explanation: A -t option has been entered for a directory that does not have a  
write permission.  
System Action: TSM cannot complete the requested operation.  
User Response: Correct the argument or permissions, and retry the operation.  
ANS9062E  
program-name: argument: not a valid directory argument for -t option.  
Explanation: An invalid directory argument has been entered for the -t option.  
System Action: TSM cannot complete the requested operation.  
1250  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Correct the argument, and retry the operation.  
ANS9063E  
ANS9064E  
ANS9067W  
error-program: file system file-system is out of nodes.  
Explanation: TSM cannot get space for the file system because the file system is  
out of inodes.  
System Action: TSM cannot get space via migration.  
User Response: Remove some files to make more inodes available and retry.  
error-program: Cannot fork a new process: error.  
Explanation: TSM cannot fork a new process that is needed.  
System Action: TSM cannot complete the requested operation.  
User Response: Free some file space by ending some processes or removing some  
files, and retry the operation.  
error-program: error updating dsmmigfstab file for file-system.  
Explanation: TSM found an error in updating the dsmmigfstab file for this file  
system.  
System Action: TSM does not update the dsmmigfstab file.  
User Response: See the preceding error message and correct the error if possible.  
Then, retry the operation. If problem persists, contact your system administrator.  
ANS9068I  
ANS9069I  
program-name: dsmmigfstab file updated for file system file-system.  
Explanation: TSM successfully updated the dsmmigfstab file for the file system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: all file systems are reactivated to previous states.  
Explanation: TSM has reactivated all file systems managed by HSM to their  
previous states before the global deactivation.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
Tivoli Storage Manager Messages  
1251  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9070I  
program-name: space management is now deactivated for all FSM file systems.  
Explanation: TSM has deactivated space management for all file systems listed in  
the dsmmigfstab file.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9071W  
ANS9072W  
ANS9073W  
program-name: error reactivating space management for all FSM file systems.  
Explanation: TSM found an error in trying to reactivate space management.  
System Action: TSM does not reactivate space management for FSM file systems.  
User Response: Make sure space management is installed correctly and retry the  
operation.  
error-program: error deactivating space management for all FSM file systems.  
Explanation: TSM found an error in trying to deactivate space management.  
System Action: TSM does not deactivate space management for FSM file systems.  
User Response: Make sure space management is installed correctly and retry the  
operation.  
program-name: error deactivating space management for file system file-system.  
Explanation: TSM found an error in trying to deactivate the file system.  
System Action: TSM does not deactivate space management for the file system.  
User Response: Make sure space management is installed correctly and retry the  
operation.  
ANS9074I  
program-name: FSM file system file-system is now deactivated.  
Explanation: TSM has deactivated space management for the file system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9075W  
program-name: error reactivating space management for file system file-system.  
Explanation: TSM found an error in trying to reactivate space management for the  
file system.  
System Action: TSM does not reactivate space management for the file system.  
1252  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Correct the error if possible and retry the operation. If the  
problem persists, contact your service representative.  
ANS9076I  
ANS9077I  
program-name: space management is now active for file system file-system.  
Explanation: TSM has reactivated space management for the file system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: removed space management from file system file-system.  
Explanation: TSM removed space management. The file system is now a native  
file system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9078W  
Space management is not removed from file system file-system.  
Explanation: TSM was not able to remove space management from this file  
system. Possible causes:  
Kernel extension is downlevel.  
Program is downlevel.  
Insufficient disk space.  
System Action: TSM is unable to complete the requested operation.  
User Response: Refer to the immediately preceding error message and retry the  
operation.  
ANS9079W  
ANS9080E  
program-name: no migrated files matching search criteria found.  
Explanation: TSM did not find any migrated files matching the search criteria.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation with a different search criteria.  
program-name: not enough space to recall all migrated files.  
Explanation: TSM detects there is not enough space in the file system to hold all  
the migrated files if all are recalled.  
System Action: TSM does not attempt to recall all the migrated files.  
User Response: Make room in the file system by increasing the file system size or  
removing some files. Retry the operation.  
Tivoli Storage Manager Messages  
1253  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9081W  
program-name: orphaned stub file(s) detected in file system file-system.  
Explanation: TSM detected one or more orphaned stub files. Either the migration  
server was changed in the client system options file after the file was migrated, or  
the migration server database is damaged.  
System Action: TSM does not attempt to remove space management from the file  
system.  
User Response: Determine the cause of orphaned stub files. Switch to the correct  
migration server and recall the migrated files. Retry the operation.  
ANS9082W  
program-name: error encountered while reconciling file system file-system.  
Explanation: TSM encountered an error performing reconciliation on the file  
system.  
System Action: TSM continues.  
User Response: Refer to other messages displayed or messages in the log to  
correct the problem. Then retry the operation.  
ANS9083W  
ANS9085E  
program-name: cannot deactivate space management on file system file-system.  
Explanation: TSM cannot deactivate space management on the file system.  
System Action: TSM continues.  
User Response: Correct the error if possible and retry the operation.  
program-name: space management has not been added to file system file-system.  
Explanation: There is no entry for the file system in the dsmmigfstab file.  
System Action: TSM will not perform space management functions on this file  
system.  
User Response: Add space management to the file system, if appropriate, and then  
retry the operation.  
ANS9086E  
program-name: error adding FSM to file system file-system.  
Explanation: TSM encountered an error and cannot add FSM to the file system.  
System Action: TSM continues.  
User Response: Refer to the preceding error message and retry the operation.  
1254  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9087I  
ANS9088W  
ANS9090E  
Space management is successfully added to file system file-system.  
Explanation: TSM has added space management to the file system, and will now  
monitor its space usage. You can also perform other space management operations  
on this file system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: an entry for file system file-system is already in the dsmmigfstab  
file.  
Explanation: TSM found that the file system is already listed in the dsmmigfstab  
file.  
System Action: TSM continues.  
User Response: None.  
program-name: file-system is not a valid file system name.  
Explanation: TSM received an invalid file system name. The file system is not  
mounted, or is not mounted correctly.  
System Action: TSM continues.  
User Response: Correct the file system name, and retry the operation.  
ANS9091I  
ANS9092W  
ANS9093W  
program-name: file file-spec is already premigrated.  
Explanation: TSM found that the file is already premigrated.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: file file-spec is not eligible for migration.  
Explanation: TSM found that the file is not eligible for migration.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: cannot update migration candidates list file-name.  
Explanation: TSM cannot update the migration candidates list because not enough  
memory is available to create a temporary file.  
Tivoli Storage Manager Messages  
1255  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing stops.  
User Response: Make some memory available by ending some processes, and then  
retry the operation.  
ANS9094W  
program-name: no candidates found in file system file-system.  
Explanation: TSM found no files eligible for migration in the file system after  
running dsmreconcile.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9096E  
User is not the owner of file filesystem-namedirectory-namefile-name so file is  
skipped.  
Explanation: The user does not own this file and cannot perform this operation.  
System Action: TSM skips the file.  
User Response: None, or if you have root-user authority, switch to root user and  
retry the operation.  
ANS9098E  
program-name: space management does not support file system file-system.  
Explanation: TSM space management does not support this type of file system.  
Space management supports only true local file systems (e.g. JFS on AIX). Space  
management does not support other types of file systems (AFS, NFS, etc).  
System Action: Processing of the file system stopped.  
User Response: None.  
ANS9099E  
program-name: space management is not active for file system file-system.  
Explanation: TSM found the file system did not have space management  
activated.  
System Action: Processing of that file system stopped.  
User Response: Reactivate space management for the file system.  
ANS9100E  
Space management has not been added to file system file-system, or FSM is not  
mounted.  
Explanation: TSM found the file system was not in a migratable state. Either  
space management was not added to the file system, or the FSM is not mounted.  
System Action: Processing of the file system stopped.  
1256  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Either add space management to the file system, or mount the  
FSM if it is not mounted. Refer to the User’s Guide for the correct syntax for  
mounting the FSM.  
ANS9101I  
No migrated files matching ’file-name’ were found.  
Explanation: You entered a search pattern or file name that cannot be found in the  
server database as a migrated file.  
System Action: Processing stopped.  
User Response: Ensure that your search pattern is correct, or specify a new search  
string.  
ANS9126E  
program-name: cannot get the state of space management for file-system: error.  
Explanation: TSM cannot determine whether space management is activated,  
deactivated, or globally deactivated on the file system.  
System Action: TSM stops the operation.  
User Response: Retry the operation.  
ANS9127I  
ANS9128I  
Process stopped, signal number=signal-number.  
Explanation: The space management process stopped.  
System Action: TSM process temporarily stops.  
User Response: Wait for process to restart.  
program-name: exported space management file system file-system.  
Explanation: TSM has exported the indicated space managed file system. You  
must import this file system to gain access to the migrated files.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9129I  
Space management normal termination, exit status = status.  
Explanation: Space management is ending normally.  
System Action: TSM exits from space management processing.  
User Response: None.  
Tivoli Storage Manager Messages  
1257  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9130W  
program-name: High threshold (value) less than low threshold (value).  
Explanation: TSM detects that the high threshold is lower than the low threshold.  
The high threshold must be higher than or equal to the low threshold.  
System Action: TSM logs the condition and continues processing other  
parameters.  
User Response: Correct the invalid input value.  
ANS9131W  
ANS9132W  
ANS9133W  
program-name: invalid size factor (value).  
Explanation: An invalid value has been entered for the size factor.  
System Action: TSM logs the condition and continues processing other  
parameters.  
User Response: Correct the invalid input value.  
program-name: invalid stub file size (value).  
Explanation: An invalid value has been entered for the stub file size setting.  
System Action: TSM logs the condition and continues processing other  
parameters.  
User Response: Correct the invalid input value.  
program-name: invalid quota factor (value).  
Explanation: An invalid value has been entered for the quota setting for the file  
system.  
System Action: TSM logs the condition and continues.  
User Response: Correct the invalid input value.  
ANS9134W  
ANS9135W  
program-name: invalid age factor (value).  
Explanation: An invalid value has been entered for the age factor setting.  
System Action: TSM logs the condition and continues.  
User Response: Correct the invalid input value.  
program-name: invalid premigration percentage (value).  
Explanation: An invalid value has been entered for premigration percentage.  
System Action: TSM logs the condition and continues.  
1258  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Correct the invalid input value.  
ANS9136W  
ANS9137W  
ANS9138W  
program-name: invalid high threshold (value).  
Explanation: An invalid value has been entered for high threshold.  
System Action: TSM logs the condition and continues.  
User Response: Correct the invalid input value.  
program-name: invalid low threshold (value).  
Explanation: An invalid value has been entered for low threshold.  
System Action: TSM logs the condition and continues.  
User Response: Correct the invalid input value.  
program-name: invalid stub file size (value) for file-system, range value..value.  
Explanation: An invalid value has been entered for the stub file size setting. The  
value should be in the range specified by the message.  
System Action: TSM does not change the value.  
User Response: Correct the invalid input value.  
ANS9139W  
ANS9140W  
ANS9141W  
program-name: invalid quota (value) for file-system, range value..value.  
Explanation: An invalid value has been entered for the quota setting. Value should  
be in the range specified by the message.  
System Action: TSM does not change the value.  
User Response: Correct the invalid input value.  
program-name: invalid size factor (value) for file-system, range value..value.  
Explanation: An invalid value has been entered for the size factor setting. Value  
should be in the range specified by the message.  
System Action: TSM does not change value.  
User Response: Correct the invalid input value.  
program-name: invalid age factor (value) for file-system, range value..value.  
Explanation: An invalid value has been entered for the age factor setting. Value  
should be in the range specified by the message.  
Tivoli Storage Manager Messages  
1259  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM does not change the value.  
User Response: Correct the invalid input value.  
ANS9142W  
program-name: file-spec: high threshold (value) less than low threshold (value)  
for file-system.  
Explanation: TSM detects that high and low thresholds specified for the file  
system are invalid values. The high threshold must be greater than or equal to the  
low threshold.  
System Action: TSM logs the condition and stops.  
User Response: Enter valid values for the high and low thresholds.  
ANS9143W  
program-name: file-spec: invalid premigration percentage (value) for file-system,  
range 0..100.  
Explanation: TSM detects an invalid premigration percentage value for the file  
system.  
System Action: TSM logs condition and stops.  
User Response: Enter a valid value for the premigration percentage.  
ANS9144W  
ANS9145W  
ANS9146E  
program-name: file-spec: invalid high threshold (value) for file-system, range  
0..100.  
Explanation: TSM detects an invalid high threshold value for the file system.  
System Action: TSM logs the condition and stops.  
User Response: Enter a valid value for the high threshold.  
program-name: file-spec: invalid low threshold (value) for file-system, range  
0..100.  
Explanation: TSM detects an invalid low threshold value for the file system.  
System Action: TSM logs the condition and stops.  
User Response: Enter a valid value for the low threshold.  
program-name: file-spec: expecting value field(s) in line line-number, found value  
field(s).  
Explanation: TSM detects too many or too few fields in an entry in the  
dsmmigfstab file.  
System Action: TSM cannot complete the requested operation.  
1260  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Edit the dsmmigfstab file manually, and then retry the operation.  
Note:Do not manually edit the dsmmigfstab file unless specifically instructed by a  
message.  
ANS9147E  
ANS9148E  
ANS9149E  
program-name: cannot read file-spec: error.  
Explanation: TSM cannot read this file.  
System Action: TSM cannot fully complete the requested operation.  
User Response: Retry the operation. Try to determine why the read failed. If the  
problem continues, check with your system administrator.  
program-name: cannot find mount point for file system file-system.  
Explanation: TSM cannot find file system mount point.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: cannot create transition stub file: error.  
Explanation: TSM cannot create transition stub file.  
System Action: TSM cannot complete the requested operation. Processing  
continues.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9150W  
Space management is not exported from file system file-system.  
Explanation: TSM was not able to export the space managed file system. Possible  
causes:  
Kernel extension is downlevel.  
Program is downlevel.  
System Action: TSM is unable to complete the requested operation.  
User Response: Refer to the immediately preceding error message and retry the  
operation.  
ANS9152E  
program-name: cannot deactivate space management for whole system: error.  
Explanation: Cannot deactivate space management for this whole system (whole  
machine).  
Tivoli Storage Manager Messages  
1261  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM cannot deactivate space management support.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9153E  
program-name: cannot reactivate space management for whole system: error.  
Explanation: Cannot reactivate space management for this whole system (whole  
machine).  
System Action: TSM cannot reactivate space management support.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9154E  
program-name: cannot deactivate space management for file system file-system:  
error.  
Explanation: Cannot deactivate space management for this file system.  
System Action: TSM unable to deactivate space management support for the file  
system.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9155E  
program-name: cannot reactivate space management for file system file-system:  
error.  
Explanation: Cannot reactivate space management for this file system.  
System Action: TSM cannot reactivate space management support to the file  
system.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9156I  
program-name: removing space management from file system file-system.  
Explanation: Space management is being removed.  
System Action: TSM is removing space management from a file system.  
User Response: Continue with operation.  
ANS9157W  
program-name: cannot turn off ENOSPC checking in kernel: error.  
Explanation: TSM cannot turn off ENOSPC checking.  
System Action: TSM cannot turn off ENOSPC checking. Processing continues.  
1262  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9158W  
ANS9159E  
ANS9160E  
ANS9161E  
ANS9162E  
program-name: cannot turn on ENOSPC checking in kernel: error.  
Explanation: TSM cannot turn on ENOSPC checking.  
System Action: TSM cannot turn on ENOSPC checking. Processing continues.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: unable to create temporary file.  
Explanation: TSM cannot create a temporary file.  
System Action: TSM cannot complete its operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: cannot write to temporary file file-spec: error.  
Explanation: TSM cannot complete writing to the temporary file.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. Determine why the write failed. If the  
problem continues, check with your system administrator.  
program-name: file-system: error in migration initialization.  
Explanation: TSM cannot initialize for migration.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: file-spec invalid: not found in path/path.  
Explanation: TSM cannot find an entry for the file system in the dsmmigfstab  
file.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
Tivoli Storage Manager Messages  
1263  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9163E  
program-name: cannot make symbolic link of file-spec to file-spec: error.  
Explanation: TSM cannot create the symbolic link.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. Ensure that there are not too many nested  
symbolic links or a recursive symbolic link. If the problem continues, check with  
your system administrator.  
ANS9164E  
ANS9165E  
ANS9166E  
program-name: cannot obtain time of day: error.  
Explanation: TSM cannot obtain the timestamp from the operating system.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: cannot open directory directory-spec: error.  
Explanation: TSM cannot open the directory.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
Cannot set password in a background process.  
Explanation: TSM cannot get a valid password from the password file locally.  
Either the password is not stored locally, or the password has been changed at the  
server. The user cannot be prompted for a new password because the process is a  
background process, for example, a daemon.  
System Action: TSM cannot complete the requested operation.  
User Response: The root user needs to provide a valid password. Enter the  
password at the prompt using the HSM client in the foreground; the password will  
then be stored locally. Retry the operation.  
ANS9167E  
program-name: cannot find directory directory-spec.  
Explanation: TSM cannot find this directory.  
System Action: TSM cannot use this directory.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
1264  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9168E  
ANS9169E  
ANS9170E  
ANS9171E  
program-name: cannot open database file-spec: error.  
Explanation: TSM cannot successfully open (lock/unlock) the database.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: cannot create directory directory-spec, reason.  
Explanation: TSM cannot create this directory.  
System Action: TSM does not create this directory.  
User Response: Verify that this directory does not already exist, and that its parent  
directory has proper permissions.  
program-name: file-system is not a mounted local file system.  
Explanation: TSM did not find that this file system is properly mounted.  
System Action: TSM ignores the file system.  
User Response: Verify that this file system is local and mounted and activated  
properly.  
Internal string is too long: error.  
Explanation: TSM internally has a long string that is beyond its capability.  
System Action: TSM cannot complete the requested operation and stops  
processing.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9178E  
program-name: cannot open file file-spec: error.  
Explanation: TSM cannot open the file.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
Tivoli Storage Manager Messages  
1265  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9179E  
program-name: cannot get real pathname of file-spec: error.  
Explanation: TSM cannot get the real pathname.  
System Action: TSM cannot complete the requested operation.  
User Response: Ensure that the pathname is valid for your system, and then retry  
the operation. If the problem continues, check with your system administrator.  
ANS9181W  
program-name: file system path/path error: error (errno: error-number).  
Explanation: TSM cannot find needed information for the file system. The  
information is stored in a status file to which the symbolic link specified in the error  
message points.  
System Action: TSM cannot complete the requested operation, and cannot  
properly work with the status file.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9183E  
ANS9184E  
ANS9186E  
program-name: file system file-system is not in the dsmmigfstab file.  
Explanation: TSM cannot find the file system in the dsmmigfstab file.  
System Action: TSM cannot complete the requested operation.  
User Response: Ensure that the file system is both valid and local. Retry the  
operation. If the problem continues, check with your system administrator.  
program-name: cannot allocate memory, error: error.  
Explanation: TSM cannot allocate adequate storage for the user.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
program-name: cannot open mounted file system file-system: error.  
Explanation: TSM cannot open mounted file system.  
System Action: TSM ignores the file system.  
User Response: Verify that this file system is mounted and activated properly.  
1266  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9188E  
Not enough memory for recall operation  
Explanation: TSM cannot allocate storage for the requested recall operation.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the recall operation. If the problem continues, check with  
your system administrator.  
ANS9189I  
ANS9191E  
Recall stopped by user  
Explanation: You requested that TSM stop the recall operation.  
System Action: Recall stopped.  
User Response: Continue with normal operations.  
Error checking file system state  
Explanation: The system cannot open /dev/dsm or cannot open the file system.  
System Action: Transaction stopped.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9192I  
Cannot disable file-system.  
Explanation: TSM cannot disable the file system.  
System Action: TSM ignores the request.  
User Response: TSM space management is not installed correctly. Read the space  
management documentation for installation instructions, or check with your system  
administrator.  
ANS9193I  
Cannot open file-system.  
Explanation: TSM cannot open the file system.  
System Action: TSM ignores the request.  
User Response: Verify whether this file system exists and whether space  
management has been added to it.  
ANS9194W  
A selective migration is in progress. Wait until it completes and retry the recall.  
Explanation: You tried a recall operation while a selective migration is in  
progress.  
Tivoli Storage Manager Messages  
1267  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM ignores the request.  
User Response: Wait until the selective migration is complete and retry the recall  
operation.  
ANS9195W  
A selective recall is in progress. Wait until it completes and retry the migration.  
Explanation: You initiated a migration operation while a selective recall is in  
progress.  
System Action: TSM ignores the request.  
User Response: Wait until the selective recall is complete and retry the migration  
operation.  
ANS9196W  
The PASSWORDACCESS option in your dsm.sys file is not set to GENERATE.  
Reset it to GENERATE and restart the HSM client.  
Explanation: The PASSWORDACCESS option in your dsm.sys file is set to  
PROMPT. It must be set to GENERATE in order for automatic space management  
services to work.  
System Action: TSM terminates the client.  
User Response: The root user must set the PASSWORDACCESS option to  
GENERATE in the dsm.sys file.  
ANS9197E  
ANS9198E  
ANS9199S  
File: file-name has already been recalled.  
Explanation: You tried to recall the a file that has already been recalled.  
System Action: TSM does not highlight the file.  
User Response: None.  
File: file-name is a resident file.  
Explanation: You tried to recall a file that is resident.  
System Action: TSM will not highlight the file.  
User Response: None.  
Cannot open /dev/fsm  
Explanation: TSM cannot open the space management device file, /dev/fsm.  
System Action: TSM cannot complete the operation.  
1268  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check to see whether TSM is installed correctly and that the  
/dev/fsm file exists. Correct the problem and retry the operation.  
ANS9230E  
Cannot unmount FSM from file system file-system. Message from umount  
command:  
Explanation: Space management control files have been updated or deleted, or  
both, for the file system. However, FSM cannot be unmounted because the file  
system is being referenced by another process.  
System Action: TSM left FSM mounted on the file system.  
User Response: Determine why unmounting the FSM failed.  
If the reason is Device Busy, try unmounting the FSM by issuing the umount  
command for the file system.  
If umount again fails, check to see if the current directory is in the file system,  
or if another process is referencing the file system, such as an NFS mount or an  
open file.  
After the file system is clear of references, issue the umount command for the file  
system. No problems will result in continuing to run with the FSM mounted and a  
machine reboot will eliminate the FSM.  
ANS9249E  
File ’file-namefile-namefile-name’ accessed during migration. File skipped.  
Explanation: The specified file-name was not migrated because the file was  
accessed by another process during the attempt to migrate it.  
System Action: TSM left the file resident.  
User Response: If you want the file migrated, stop the process which is accessing  
the file and retry the migration.  
ANS9250I  
ANS9251E  
File system ’file-system’ reconciliation completed.  
Explanation: TSM has finished reconciling the file system.  
System Action: TSM continues.  
User Response: Continue with normal operations.  
ProgramName: Cannot parse command-line options correctly.  
Explanation: An internal program error occurred trying to parse the command-line  
arguments.  
System Action: The program is not able to process the request.  
Tivoli Storage Manager Messages  
1269  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Use the -h or -help option to see what options are allowed on the  
command-line, and then retry the request. If this problem continues, contact your  
service representative.  
ANS9254E  
Error encountered while adding implicit excludes to the include-exclude list.  
Explanation: Error encountered when implicitly excluded files are being added to  
the include-exclude list.  
System Action: TSM cannot proceed.  
User Response: Retry the operation. If the problem persists, contact your service  
representative.  
ANS9255E  
program-name: invalid value found in the dsmmigfstab file for file system  
file-spec.  
Explanation: TSM detects invalid values in the dsmmigfstab file. The entry that  
contains the invalid values is for file system file-spec  
System Action: TSM cannot perform migration until the error is corrected in the  
table.  
User Response: Find the invalid values in the table entry and correct them using  
the dsmmigfs command or the HSM graphical user interface.  
ANS9256E  
File ’file-namefile-namefile-name’ is currently opened by another process. File  
skipped.  
Explanation: The specified file-name was not migrated because the file was open  
by one or more other processes.  
System Action: TSM left the file resident.  
User Response: If you want the file migrated, stop the processes which currently  
have the file open and retry the migration.  
ANS9257E  
Server ’server-name’ does not support space management.  
Explanation: The specified server-name does not support space management. It is  
a downlevel server, or a platform that does not support space management.  
System Action: TSM failed the operation.  
User Response: If you want to use the space management function, make sure you  
connect to a server that supports space management.  
1270  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9263W  
program-name: cannot reserve transition stub file for file system file-system:  
reason.  
Explanation: TSM cannot reserve transition stub file. TSM tries to reserve some  
space for the transition stub file for emergency cases. At this point, there is either  
not enough space or inodes to allow the reservation. The attempt to reserve the  
transition stub file will be made again during reconciliation.  
System Action: TSM cannot reserve space for the transition stub files. Processing  
continues.  
User Response: If possible, make more space or inodes available and run  
reconciliation.  
ANS9264E  
program-name: TSM space management does not support file systems with  
mount points that are relative paths or contain symbolic links.  
Explanation: TSM does not support adding space management to file systems  
with mount points which are either relative path names or contain symbolic links.  
System Action: TSM does not add space management to the file system.  
User Response: Change the file system mount point so that it is not a relative path  
or does not contain symbolic links, and then retry the operation.  
ANS9267E  
ANS9280E  
ANS9281E  
program-name: File system file-system has exceeded its quota.  
Explanation: TSM detects that the file system has exceeded its quota. No more  
data can be migrated out of this file system.  
System Action: TSM will not migrate files from this file system.  
User Response: Recall some files, or ask the system administrator to increase the  
quota for this file system.  
program-name: cannot get space management kernel extension ID. Error : error.  
Explanation: The program cannot determine the level of space management client  
kernel extension.  
System Action: TSM stops the operation.  
User Response: Ensure that space management is installed correctly, and then  
retry the operation. If the problem continues, check with your system administrator.  
Space management kernel extension is downlevel from the user program.  
Explanation: The space management kernel extension on the system is downlevel  
from the user program that is currently running. Unexpected results may occur.  
Tivoli Storage Manager Messages  
1271  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM stops processing the kernel extension.  
User Response: Upgrade the space management kernel extension to the correct  
level, and then retry the operation.  
ANS9282E  
User program is downlevel from the space management kernel extension.  
Explanation: The user program that is currently running is downlevel from the  
space management kernel extension on the system. Unexpected results may occur.  
System Action: TSM stops processing the extension.  
User Response: Upgrade the user program to the correct level, and then retry the  
operation.  
ANS9283K  
Attempting to access remote file.  
Explanation: The space management kernel extension is attempting to access a  
file that is not stored locally. If the file is migrated, TSM is attempting to access it  
from an TSM space management server.  
System Action: TSM waits for the kernel to access the file.  
User Response: None.  
ANS9284K  
File access waiting for migration to complete.  
Explanation: The file being accessed is currently being migrated. Access to this  
file must wait until the migration process is finished.  
System Action: TSM waits until the file migration is completed.  
User Response: None.  
ANS9285K  
Cannot complete remote file access.  
Explanation: The space management kernel extension cannot complete the remote  
file access. The file may be migrated to an TSM migration server. The file cannot  
be recalled to the local machine. The server could be temporarily disabled.  
System Action: TSM terminates the current operation.  
User Response: Check to see whether the server has been disabled by the system  
administrator, then retry the operation.  
ANS9286K  
File migration has been discontinued.  
Explanation: Migration stops because the file is being migrated by another  
process.  
1272  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM terminates the current operation.  
User Response: None.  
ANS9287I  
Out of free space or inodes in file system file-system to migrate or recall.  
Explanation: The file system is full. No more free space or free inodes can be  
allocated for the transaction file that is required for migration or recall.  
System Action: TSM terminates the current operation for this file system.  
User Response: Remove some files from the file system, and then run  
reconciliation. Retry the operation.  
ANS9288I  
File file-name of size file-size is too small to qualify for migration.  
Explanation: The file is smaller than the minimum size required for migration. A  
file is considered for migration only if its size is greater than both the stub file size  
specified for the file system plus 1 byte and the block size defined for the file  
system.  
System Action: TSM does not migrate this file because it will not free additional  
space.  
User Response: None.  
ANS9289I  
Object ’dir-name’ is a directory. It is skipped for migration.  
Explanation: The object is a directory. It is not migrated. Space management does  
not migrate directories.  
System Action: TSM does not migrate this object because it is a directory.  
User Response: None.  
ANS9290I  
File file-name of type file-type is skipped for migration.  
Explanation: The file either cannot be read, is not a regular file, or its type is  
unknown to space management. Space management only migrates regular files and  
does not migrate directories.  
System Action: TSM does not migrate this file.  
User Response: None.  
Tivoli Storage Manager Messages  
1273  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9291E  
program-name: A conflicting space management program is already running in  
the file-system file system. Re-run this program later in this file system.  
Explanation: TSM detected another program running in the file system that cannot  
run at the same time as the program your tried to initiate. The following programs  
cannot run at the same time for a file system:  
dsmreconcile  
dsmautomig  
dsmmigfs remove.  
Also, dsmmigfs remove cannot run while a migration process is running in the file  
system.  
System Action: TSM will not run the program at this time.  
User Response: Try running the program later.  
ANS9292E  
program-name: Cannot access lock file lock-file/lock-filelock-file: error  
Explanation: TSM cannot access a lock file due to an error. The lock file provides  
serialization of certain programs to prevent conflicting processes from running at the  
same time.  
System Action: TSM will not run the program at this time.  
User Response: Check the permissions on the directories leading up to the lock  
file and also the permissions on the program executable.  
ANS9293E  
TSM space management cannot access ERRORPROG error-program:error  
Explanation: TSM encountered an error trying to access the program specified  
with the ERRORPROG option in your client system options file (dsm.sys). This  
message will appear only the first time this error occurs.  
System Action: TSM cannot send a severe error message to the specified error  
message program.  
User Response: Check to make sure the program exists and that it accepts  
standard input when run. It is usually best if ERRORPROG specifies the fully  
qualified file name of the program.  
ANS9294I  
No files matching ’file-name’ were found.  
Explanation: You entered a search pattern or file name that cannot be found in the  
local file system.  
System Action: Processing stopped.  
User Response: Ensure that your search pattern is correct, or specify a new search  
string.  
1274  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9297I  
File file-name is skipped for migration: No backup copy found.  
Explanation: A management class is assigned to the file with the attribute  
MIGREQUIRESBKUP set to YES. This requires a current backup copy of the file  
before migration. However, there is no backup copy found on the migration server.  
This file will not be migrated. Note: TSM checks only the migration server for a  
backup copy. If the migration server and backup server are different servers, TSM  
does not find a backup copy of the file.  
System Action: TSM does not migrate this file.  
User Response: Back up this file on the migration server, or assign a management  
class to this file that does not require a current backup copy. Retry the operation.  
ANS9298I  
File file-name is skipped for migration: Backup copy found is not current.  
Explanation: A management class is assigned to the file with the attribute  
MIGREQUIRESBKUP set to YES. This requires a current backup copy of the file  
before migration. However, the backup copy found on the migration server is an old  
version. This file will not be migrated. Note: TSM checks only the migration server  
for a backup copy. If the migration server and backup server are different servers,  
there must be a valid backup copy of the file on the migration server.  
System Action: TSM does not migrate this file.  
User Response: Back up the current file on the migration server, or assign a  
management class to this file that does not require a current backup copy. Retry the  
operation.  
ANS9299I  
Cannot get the number of migrated files for file system file-system.  
Explanation: Failed to get the number of migrated files on the file system. The  
number is stored in the status file for the file system.  
System Action: If you are removing space management from the file system,  
processing stops. Space management is not removed.  
User Response: Run reconciliation to reconcile the file system. Retry operation.  
ANS9300I  
Migrated files found in file system file-system. Check for any error encountered  
during recall.  
Explanation: Remove space management failed because there are migrated files in  
the file system. TSM was unable to recall any files, or some of the migrated files  
may have failed during a recall operation.  
System Action: TSM remove processing stops.  
Tivoli Storage Manager Messages  
1275  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check for error messages that occurred during the recall process,  
correct any problems, and retry the remove process.  
ANS9301I  
Cannot remove the entry for file-system from the dsmmigfstab file.  
Explanation: The entry for the file system in the dsmmigfstab file cannot be  
removed. Possible reasons:  
Not enough memory to create temporary file name for temporary file system  
table.  
Not enough free space or inodes to create temporary file system table  
Cannot open the real and/or temporary file system table files.  
System Action: TSM does not remove the entry from the dsmmigfstab file.  
User Response: Manually edit the dsmmigfstab file and delete the entry.  
ANS9302E  
Mount FSM: ERROR - file-system is not in the dsmmigfstab file. Check the  
/etc/adsm/SpaceMan/config/dsmmigfstab file, or add space management to the  
file system.  
Explanation: TSM cannot mount the file system because it is not listed in the  
dsmmigfstab file.  
System Action: TSM does not mount the FSM to the file system.  
User Response: If you previously added space management to the file system,  
check the /etc/adsm/SpaceMan/config/dsmmigfstab file to see whether the entry has  
been removed or commented out. If you want to add space management to the file  
system, use 'dsmmigfs add'.  
ANS9303E  
Mount FSM: ERROR - file system type ’FSM’ was not found. TSM space  
management is not installed correctly. Please read the space management  
documentation for installation instructions.  
Explanation: TSM cannot mount the file system because the file 'FSM' entry is  
missing from /etc/vfs.  
System Action: TSM does not mount the FSM to the file system.  
User Response: AIX only. TSM space management is not installed correctly. Read  
the space management documentation for installation instructions.  
ANS9304E  
Mount FSM: ERROR - invalid source (object) path ’source-path’: error  
Explanation: TSM cannot mount the file system due to an invalid path.  
System Action: TSM does not mount the FSM to the file system.  
User Response: Correct the problem and retry the mount.  
1276  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9305E  
Mount FSM: ERROR - invalid mount (stub) path ’mount-path’: error  
Explanation: TSM cannot mount the file system due to an invalid path.  
System Action: TSM does not mount the FSM to the file system.  
User Response: Correct the problem and retry the mount. Make sure the directory  
exists.  
ANS9306E  
Mount FSM: ERROR - mount-path must be a directory  
Explanation: TSM cannot mount the file system because the mount path is not a  
directory.  
System Action: TSM does not mount the FSM to the file system.  
User Response: Correct the problem and retry the mount. Make sure the mount  
path is a directory.  
ANS9307W  
Mount FSM: TSM space management is already mounted on mount-path  
Explanation: TSM cannot mount the file system because the file system is already  
mounted.  
System Action: TSM does not mount the FSM to the file system.  
User Response: None.  
ANS9308E  
Mount FSM: ERROR - mount-path is not a supported native file system  
Explanation: TSM cannot mount the file system because it is not a supported  
native file system.  
System Action: TSM does not mount the FSM to the file system.  
User Response: The file system must be one of the supported native file systems  
in order for the TSM space management to mount it.  
ANS9309I  
Mount FSM: TSM space management mounted on mount-path  
Explanation: TSM successfully mounted the FSM to the file system.  
System Action: TSM space management now manages the file system.  
User Response: None.  
Tivoli Storage Manager Messages  
1277  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9310E  
ANS9311E  
Mount FSM: ERROR - cannot FSM mount source-path on mount-path: error  
Explanation: TSM cannot mount the file system due to the specified error.  
System Action: TSM does not mount the FSM to the file system.  
User Response: Correct the problem and retry the mount.  
Mount FSM: ERROR - cannot unlock file system, internal error: error  
Explanation: TSM cannot unlock the internal file system lock.  
System Action: TSM does not allow non-root user access to the file system.  
User Response: Attempt to unmount the file system, and try the mount again. If  
the problem continues, contact your service representative.  
ANS9312S  
program-name: Cannot change owner/group on file: file-name: error  
Explanation: TSM cannot change the ownership or group, or both for the  
specified file. This change is necessary for space management to run properly.  
System Action: TSM cannot continue processing.  
User Response: Ensure that directory permissions allow the file owner or group to  
be changed. Reissue the command.  
ANS9313I  
One or more files will be retrieved from or stored to offline media.  
Explanation: For the backup or archive operation, one or more files must be sent  
to offline storage media (generally tape), or a migrated file must be recalled from  
offline storage media. The waiting time depends on your site’s offline storage  
management policies.  
System Action: TSM waits for offline storage media to become available and then  
continues.  
User Response: None.  
ANS9318W  
program-name: error encountered while undeleting file system file-system.  
Explanation: TSM encountered an error performing undelete on the file system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
1278  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9400W  
program-name: Recovered program-name. The daemon was either not started or  
in corrupted state.  
Explanation: TSM HSM daemon breakdown with automatic recovery by the  
dsmwatchd.  
System Action: Restarting the daemon.  
User Response: Continue with normal operation.  
ANS9401E  
ANS9402E  
ANS9403E  
program-name: Cannot kill recall daemon.  
Explanation: TSM A request for killing the recall daemon failed. This may happen  
during node failover.  
System Action: none.  
User Response: Continue with normal operation unless further errors occur.  
program-name: Cannot notify to recover HSM operations on a failure node.  
Explanation: TSM In order to takeover the functionality of a malfunctional  
partner node the dsmwatchd must notify the local daemons.  
System Action: none.  
User Response: Contact service representative.  
program-name: The local HSM functionality cannot be recovered. Trying to  
initiate failover to another node.  
Explanation: TSM If the GPFS daemon crashes or the local HSM daemons cannot  
perform their function for whatever reason the dsmwatchd will try to migrate the  
functionality to another node.  
System Action: Migrate HSM functionality to another node.  
User Response: Check failure node. It may be necessary to recover the local  
GPFS daemon.  
ANS9404W  
program-name: Received failover request from node ID with frame ID . Trying  
to takeover remote filesystems.  
Explanation: TSM The local dsmwatchd received a notification about a failing  
HSM node. It will try to takeover its managed filesystems.  
System Action: HSM will try to takeover the managed filesystems from a failure  
node.  
User Response: Check failure node.  
Tivoli Storage Manager Messages  
1279  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9405W  
program-name: The takeover of filesystem path succeeded.  
Explanation: TSM During a failover scenario the local node will try to takeover  
the managed filesystems of a failure node.  
System Action: HSM will try to takeover the managed filesystems from a failure  
node.  
User Response: Check failure node.  
ANS9410E  
ANS9411E  
program-name: Shutting down the local HSM functionality.  
Explanation: TSM After a HSM failure the local HSM daemons get disabled.  
System Action: Disable HSM locally.  
User Response: Check node consistency.  
program-name: Unable to leave the failover group due to problems with SP  
Group Services.  
Explanation: TSM To disable the failover mechanism locally HSM must log off  
from the SP wide Group Service. This attempt did not succeed.  
System Action: None.  
User Response: Check SP Group Service for consistency.  
ANS9412E  
program-name: Failover is disabled on the local machine. Aborting failover ...  
Explanation: TSM Failover operations were disabled either by the system or the  
user.  
System Action: None.  
User Response: Check failover policy if necessary.  
ANS9413W  
program-name: The remote node was able to recover from failure situation.  
Aborting takeover ...  
Explanation: The remote dsmwatchd was able to recover from the failure situation  
during the local takeover operation.  
System Action: None.  
User Response: Check failure node for consistency.  
1280  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9414E  
ANS9415W  
program-name: Unable to create file-name in the SDR. Aborting ...  
Explanation: An update of an SDR object failed.  
System Action: Aborting operation.  
User Response: Check SDR consistency.  
program-name: The HSM service provider on Node ID: node with Frame ID:  
frame left the failover group voluntarily.  
Explanation: Failover was disabled on a remote HSM node.  
System Action: None.  
User Response: None.  
ANS9416W  
program-name: The HSM service provider on Node ID: node with Frame ID:  
frame joined the failover group.  
Explanation: TSM Failover was activated on a remote HSM node.  
System Action: None.  
User Response: None.  
ANS9417E  
program-name: The synchronization between the dsmmigfstab as stored in the  
SDR and the local dsmmigfstab failed. Aborting operation ...  
Explanation: For unknown reasons it was not possible to merge the local  
dsmmigfstab with the node set version of the file. Manual correction required.  
System Action: Aborting operation.  
User Response: Please correct and merge /etc/adsm/SpaceMan/config/dsmmigfstab  
with /etc/adsm/SpaceMan/config/dsmmigfstab.old manually. Then store the resulting  
file to the SDR via SDRReplaceFile localFile dsmmigfs.ID If the problem is not  
resolved, call your service representative.  
ANS9418W  
program-name: File file-name is locked at the moment. Will try to acquire the  
SDR lock in a few seconds again.  
Explanation: SP-wide files are stored in the SDR. These files can be accessed as  
soon as it is possible to set a certain SDR lock. If a second process holds this lock,  
access to the file is denied till the lock is released.  
System Action: TSM None.  
Tivoli Storage Manager Messages  
1281  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Wait. If the situation does not get resolved within a reasonable  
amount of time (about 1 min.), execute dsmmigfs SDRreset. This will reset all  
activated locks in the SDR for the local GFPS node set.  
ANS9419E  
program-name:The filesystem filesystem-name is either already managed locally  
or under the contol of a remote HSM instance.  
Explanation: A GPFS filesystem can be managed just once.  
System Action: Aborting operation.  
User Response: Execute dsmmigfs query -detail to have a look at the current  
HSM configuration within the local GFPS node set.  
ANS9420E  
program-name: An update of the configuration files in the SDR is not allowed as  
long as failover is disabled on the local machine.  
Explanation: You cannot update configuration files in the SDR when failover is  
disabled on the local machine.  
System Action: TSM Aborting operation.  
User Response: Do nothing, or activate failover by using dsmmigfs enableFailover  
before running dsmmigfs SDRupdate.  
ANS9421W  
program-name: Recovered from Lock on SDR File file-name  
Explanation: This output relates to ANS9418W. A previously blocked SDR file  
got unlocked.  
System Action: TSM continues.  
User Response: None.  
ANS9422E  
program-name: It was not possible to access the SDR File file-name within an  
appropiate amount of time. Aborting operation ...  
Explanation: This output relates to ANS9418W. A file in the SDR remains  
blocked.  
System Action: Aborting operation.  
User Response: If the problem persists execute dsmmigfs SDRreset.  
ANS9423E  
program-name: Setting the default partiton name failed! Aborting operation ...  
Explanation: The application needs to have access to the SP Group Services. In  
this context it tries to extract the default partition name for the local system as  
provided by spget_syspar. The data extraction failed.  
1282  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Aborting operation.  
User Response: Check node consistency.  
ANS9424E  
program-name: Severe problem! It was not possible to send a message to the SP  
Group Services.  
Explanation: The Failover environment requires proper access to the SP Group  
Services. The distribution of a message failed.  
System Action: Aborting operation.  
User Response: Check node consistency.  
ANS9425E  
program-name: It was not possible to notify the dsmwatchd in order to  
distribute a message within the failover group. The data of the current  
operation may get lost.  
Explanation: Some HSM commands need to inform the dsmwatchd about the  
current operation. This notification failed.  
System Action: Aborting operation.  
User Response: Restart the GPFS daemon and check that the DMApi support is  
active by executing /usr/lpp/mmfs/bin/mmlsfs deviceName.  
ANS9428E  
program-name: The takeover of filesystem filesystem failed.  
Explanation: A remote node requested the takeover of a filesystem but the local  
activation failed.  
System Action: Aborting operation.  
User Response: Check whether the filesystem gets managed by another node. If  
not, recover the initial node and restart the HSM service.  
ANS9432E  
Severe problem! It was not possible to start the dispatcher thread for the  
communication with the SP Group Services. The failover environment is in  
corrupted state now.  
Explanation: Unable to start required thread.  
System Action: Aborting operation.  
User Response: Check node consistency.  
Tivoli Storage Manager Messages  
1283  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9433E  
ANS9442E  
program-name: dm_send_msg failed with errno Errno.  
Explanation: Unable to execute DMApi call.  
System Action: Aborting operation.  
User Response: Check consistency of the GPFS daemon.  
program-name: It appears that another dsmmigfs add/rem/update command is  
in process within the local GPFS nodeset. Please wait a few moments, then  
repeat the operation. If a previous dsmmigfs command was aborted, there  
could be a stale lock in the SDR. If so, run dsmmigfs SDRreset to fix the  
problem.  
Explanation: There can only be one instance of dsmmigfs add/rem/update running  
within a GPFS nodeset at the same time.  
System Action: Aborting operation.  
User Response: Wait for a bit and try again. If no other instance of dsmmigfs is  
running within the local GPFS nodeset run dsmmigfs SDRreset.  
ANS9443E  
ANS9449W  
ANS9450W  
program-name: The operation cannot be executed in a deactivated failover  
environment.  
Explanation: The operation relies on an active failover environment.  
System Action: Aborting operation.  
User Response: Run dsmmigfs enableFailover on the local node and repeat the  
operation.  
program-name: Forced deactivation of the local failover environment!  
Explanation: TSM Failover was initiated or a problem with the group services  
occured.  
System Action: Continuing failover or aborting operation.  
User Response: Check HSM and SP Group Services environments. Execute  
dsmmigfs enableFailover after resolving the problem.  
program-name: No eligible filesystem for takeover.  
Explanation: None of the locally mounted GPFS filesystems matches with the  
remotely managed filesystems of the failure node.  
System Action: Aborting takeover operation.  
1284  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check that the filesystems of the remote failure node get managed  
elsewhere within the node set.  
ANS9451E  
ANS9452E  
ANS9453W  
ANS9454W  
ANS9455E  
program-name: GPFS or the SP switch is down locally. Aborting takeover  
activies ...  
Explanation: TSM GPFS is not functional locally.  
System Action: Aborting takeover operation.  
User Response: Check switch and VSD status. The local system must be  
unfenced.  
program-name: The DMApi is not functional locally. Aborting takeover activies  
...  
Explanation: The operation stopped because the DMApi interface is not  
accessible.  
System Action: Aborting takeover operation.  
User Response: Check GPFS status.  
program-name: Performing synchronization between the local and global  
configuration.  
Explanation: The local node received a request from a remote node to  
synchronize with the global SDR configuration.  
System Action: Synchronizisation proceeds.  
User Response: None.  
program-name: Performing synchronization between the local and global file  
event handling.  
Explanation: The local node received a request from a remote node to  
synchronize with the global file event handling (DMApi event disposition).  
System Action: Synchronizisation proceeds.  
User Response: None.  
program-name: Unable to join the local failover group with rc=return-code!  
Explanation: SP Group services reported a problem accessing/creating an HSM  
group.  
System Action: Aborting operation.  
Tivoli Storage Manager Messages  
1285  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check PSSP environment on the local node.  
ANS9456W  
program-name: Unable to subscribe to the local failover group with  
rc=return-code!  
Explanation: SP Group services reported a problem subscribing to the HSM  
group.  
System Action: Aborting operation.  
User Response: Check PSSP environment on the local node.  
ANS9457W  
ANS9458W  
ANS9500W  
program-name: Subscribed successfully to the local failover group!  
Explanation: Subscribing to the Group Services HSM failover group succeeded.  
System Action: Processing continues.  
User Response: None.  
program-name: Joined successfully to the local failover group!  
Explanation: Joining the Group Services HSM failover group succeeded.  
System Action: Processing continues.  
User Response: None.  
program-name: cannot disposition the mount event. Reason: error  
Explanation: The system wide mount event could not be dispositioned. Mount  
events will not be received by this daemon.  
System Action: TSM continues.  
User Response: Try to resolve the problem and restart the recall daemon. If the  
problem cannot be resolved immediately, kill and restart the recall daemon after an  
TSM space management supported file system has been added using dsmmigfs or  
after a file system has been mounted using the mount command.  
ANS9501W  
program-name: cannot set event disposition on session session for file system  
mountdir token = token. Reason : error  
Explanation: Events could not be dispositioned on the file system. No events will  
be received for this filesystem. HSM is not enabled for this file system.  
System Action: TSM continues.  
1286  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: The file system must be one of the supported native file systems  
in order for the TSM space management to support it. Verify that the mount options  
the file system are correct. Correct the problem and remount the file system.  
ANS9502W  
program-name: cannot remove event disposition on session session for file  
system mountdir token = token. Reason : error  
Explanation: Event dispositions could not be removed from the file system.  
System Action: TSM continues.  
User Response: Correct the problem and retry the operation.  
ANS9503I  
program-name: events have been set and dispositioned on session session for file  
system filesystem-name  
Explanation: Setting events and dispositioning these on a DM session enables the  
file system for TSM space management support.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9504W  
program-name: The file system filesystem-name is not mounted or is mounted  
with wrong options.  
Explanation: Either the file system is not mounted or it has been mounted with  
incorrect options.  
System Action: TSM continues.  
User Response: Mount the file system or remount it with corrected mount options.  
ANS9505E  
program-name: cannot initialize DM services. Reason: error  
Explanation: TSM space management cannot initialize the DM services.  
System Action: TSM cannot start space management support.  
User Response: Correct error and retry operation. Make sure that DM services  
have been installed on the system (Hierarchical Storage Management Support).  
ANS9506E  
program-name: cannot query the right on session session token = token. Reason :  
error  
Explanation: TSM space management cannot query the right that is held on a file  
during the recall process.  
System Action: Processing of the file is interrupted.  
Tivoli Storage Manager Messages  
1287  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Continue with normal operation.  
ANS9507E  
ANS9508W  
ANS9509W  
program-name: cannot request the right on session session for file handle  
filehandle token = token. Reason : error  
Explanation: TSM space management cannot request the required right on a file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
program-name: cannot release the right on session session for file handle =  
filehandle token = token. Reason : error  
Explanation: TSM space management cannot release the right on a file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
program-name: received an unexpected event of type event-type on session  
session.  
Explanation: TSM space management daemon received an unexpected event. This  
event has not been dispositioned.  
System Action: TSM ignores event and continues.  
User Response: Continue with normal operation.  
ANS9510E  
program-name: cannot get event messages from session session, expected max  
message-length = msglen, returned message-length = return-length. Reason :  
error  
Explanation: TSM space management encountered an error while trying to receive  
a message on a DM session.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
ANS9511E  
program-name: cannot read DM attributes on session session for file handle =  
handle token = token. Reason : error  
Explanation: TSM space management cannot read the DM attributes of a DM  
object, usually a file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
1288  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9512E  
program-name: cannot set DM attributes on session session for file handle =  
filehandle token = token. Reason : error  
Explanation: TSM space management cannot set DM attributes for a DM object,  
usually a file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
ANS9513E  
program-name: cannot remove DM attributes on session session for file handle =  
filehandle token = token. Reason : error  
Explanation: TSM space management cannot remove DM attributes for a DM  
object, usually a file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
ANS9514E  
program-name: cannot create a file handle from path. Reason: error  
Explanation: TSM space management cannot create a file handle from the given  
file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
ANS9515E  
program-name: cannot set the migration information. Reason: error  
Explanation: TSM space management cannot set the migration information of a  
file, because space management cannot create a file handle from the file and/or from  
the file system.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
ANS9516E  
program-name: cannot create an user event message on session session. Reason:  
error  
Explanation: TSM space management cannot create an user event message,  
needed to reference rights on a file to be processed.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
Tivoli Storage Manager Messages  
1289  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9517E  
program-name: cannot clear all event messages from session session. Reason:  
error  
Explanation: TSM space management is in the process of destroying a DM  
session. There are still - unexpected - event messages on this session that could not  
be responded to.  
System Action: TSM DM session is not destroyed.  
User Response: See your system administrator.  
ANS9518E  
program-name: cannot respond to an event message on session session using  
token token Reason : error  
Explanation: An event message could not be responded to (returned to the  
system).  
System Action: TSM space management continues.  
User Response: If a user process is unexpectely blocked and cannot be killed, see  
your system administrator.  
ANS9519W  
ANS9520E  
ANS9521E  
program-name: cannot set eventlist for a file system on session session token =  
token fs-handle = fs-handle. Reason : error  
Explanation: An eventlist could not be set on a file system. None of the events  
will be generated by the system on this file system.  
System Action: TSM space management continues.  
User Response: Resolve the problem and retry the operation.  
program-name: cannot set a managed region on session session for file handle =  
filehandle token = token. Reason : error  
Explanation: A managed region could not be set on a file. No events will be  
generated for this file.  
System Action: Processing of the file is interrupted.  
User Response: If this error recurs, see your system administrator.  
program-name: cannot get the file attributes on session session for file handle =  
handle token = token. Reason : error  
Explanation: TSM space management cannot read the attributes of a file.  
System Action: Processing of the file is interrupted.  
User Response: If this error recurs, see your system administrator.  
1290  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9522E  
ANS9523E  
ANS9524W  
program-name: file for migration has changed - migration skipped for file  
handle = filehandle  
Explanation: The file in migration has been modified.  
System Action: TSM stopped migration of the file.  
User Response: Retry operation.  
program-name: is unable to verify the stubsize for the file on session session file  
handle = filehandle token = token. Reason : error  
Explanation: A correct stubsize could not be determined by the system.  
System Action: TSM stopped migration of the file.  
User Response: Resolve the problem and retry the operation.  
program-name: adjusted stubsize to an allowed value on session session file  
handle = filehandle token = token old stubsize = old-size new stubsize = new-size  
Explanation: The predefined stubsize for the file was not valid. The system  
corrected the stubsize.  
System Action: TSM space management continues.  
User Response: Continue with normal operation.  
ANS9525E  
program-name: is unable to create a stubfile on session session for file handle =  
handle token = token. Reason : error  
Explanation: An error occurred while creating a stub file.  
System Action: Processing of the file is interrupted.  
User Response: Continue with normal operation.  
ANS9526E  
ANS9527E  
program-name: cannot open the state file filename for writing. Reason: error  
Explanation: The state file (global or file system state file) could not be opened.  
System Action: TSM stops processing.  
User Response: Resolve the problem and retry the operation.  
program-name: cannot write to the state file filename. Reason: error  
Explanation: TSM space management could not write to the state file.  
System Action: TSM stops processing.  
Tivoli Storage Manager Messages  
1291  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Resolve the problem and retry the operation.  
ANS9528W  
ANS9529W  
program-name: cannot read from the state file filename. Reason: error  
Explanation: TSM space management could not read from the state file.  
System Action: TSM stops processing.  
User Response: Resolve the problem and retry the operation.  
program-name: cannot obtain handle of file system state file  
Explanation: TSM space management could not find the handle of a file system  
state file, that is stored in the global state file. This can be true if either space  
management is querying a file system that has no HSM support added, or the file  
system state file is corrupted, or the global state file is corrupted.  
System Action: TSM continues or stops processing, depending on the situation.  
User Response: If processing has stopped, resolve the problem and retry the  
operation.  
ANS9530W  
program-name: cannot remove an entry for file-system from the global state file.  
Explanation: The entry for the file system in the dmiFSGlobalState file cannot be  
removed. Possible reasons:  
Not enough memory to create temporary file name for temporary file system  
table.  
Not enough free space or inodes to create temporary file system table  
Cannot open the real and/or temporary file system table files.  
System Action: TSM does not remove the entry from the global state file.  
User Response: Resolve the problem and retry the operation.  
ANS9531E  
program-name: cannot create a DM session: old session = oldsession session info  
= session-info. Reason : error  
Explanation: TSM space management could not create a DM session.  
System Action: TSM stops processing.  
User Response: See your system administrator.  
ANS9532W  
program-name: cannot destroy the session session. Reason: error  
Explanation: TSM space management could not destroy a DM session.  
System Action: TSM continues.  
1292  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: See your system administrator.  
ANS9533W  
ANS9534W  
ANS9535E  
ANS9536W  
program-name: failed getting all sessions. Reason: error  
Explanation: TSM space management could not get all DM sessions on the  
system.  
System Action: TSM stops processing.  
User Response: See your system administrator.  
program-name: cannot query a session. Reason: error  
Explanation: TSM space management could not query a DM session on the  
system.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: a file handle could not be created from the file descriptor  
file-descriptor. Reason: error  
Explanation: TSM space management could not create a file handle.  
System Action: Processing of the file is interrupted.  
User Response: If this error recurs, see your system administrator.  
program-name: the file system filesystem-name could not be umounted. Reason :  
error  
Explanation: The file system could not be unmounted to remove HSM support  
option from the mount command. HSM has been removed from the file system. All  
files on the file system are local. No migration will be possible.  
System Action: TSM continues.  
User Response: Resolve the problem and remount the file system according to the  
entry in /etc/fstab.  
ANS9537E  
program-name: the file system filesystem-name could not be mounted. Reason :  
error  
Explanation: The file system could not be mounted.  
System Action: TSM stops processing.  
User Response: Resolve the problem and retry the operation.  
Tivoli Storage Manager Messages  
1293  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9538W  
ANS9539E  
ANS9542E  
ANS9543W  
program-name: request request for DM file attributes not recognized  
Explanation: An unknown request type has been encountered that cannot be  
handled.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: cannot create a file system handle from the file handle =  
filehandle. Reason : error  
Explanation: A file system handle could not be created from a file handle.  
System Action: TSM continues.  
User Response: Continue with normal operation.  
program-name: the file attributes could not be set on session session for file  
handle = filehandle token = token flag = flag Reason : error  
Explanation: TSM space management could not update file attributes.  
System Action: Processing of the file is interrupted.  
User Response: If this error recurs, see your system administrator.  
program-name: cannot reserve blocks for nospace condition on file system  
filesystem-name. Reason: error  
Explanation: TSM space management could not reserve blocks on the file system  
to be used in a nospace condition.  
System Action: TSM continues.  
User Response: Resolve the problem, then restart the monitor daemon.  
ANS9544W  
program-name: cannot obtain allocation info on session sessionL file handle =  
filehandle token = tokenL offset=offsetL number of extents = nextents (returned =  
nreturned) Reason: error  
Explanation: TSM space management could not get allocation information of a  
file.  
System Action: Processing of the file is interrupted.  
User Response: If this error recurs, see your system administrator.  
1294  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9545E  
ANS9546I  
ANS9547W  
program-name: cannot get lock for lockdirlockfile to continue processing.  
Explanation: TSM space management could not obtain a lock for a file.  
System Action: Processing stopped.  
User Response: Resolve the problem and retry the operation.  
Attempting to access remote file.  
Explanation: A process is attempting to access a file that is not stored locally.  
System Action: waits for space management to recall the file.  
User Response: Continue with normal operation.  
File access denied because file is in migration.  
Explanation: The file being accessed is currently being migrated. Access to this  
file is denied during the migration process.  
System Action: Retry after migration has been completed.  
User Response: Continue with normal operation.  
ANS9548W  
Cannot complete remote file access.  
Explanation: TSM space management cannot complete the remote file access. The  
file may be migrated to an TSM migration server. The file cannot be recalled to the  
local machine. The server could be temporarily disabled.  
System Action: TSM terminates the current operation.  
User Response: Check to see whether the server has been disabled by the system  
administrator, then retry the operation.  
ANS9549W  
File migration has been discontinued.  
Explanation: Migration stops because the file is being migrated by another  
process or a system error occurred.  
System Action: TSM terminates the current operation.  
User Response: Continue with normal operation.  
ANS9550W  
File recall has been discontinued.  
Explanation: Recall stops because the file being recalled would cause the file  
system to run out of space.  
Tivoli Storage Manager Messages  
1295  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM terminates the current operation.  
User Response: Increase the file system space, or remove unneeded files, or wait  
until space management has migrated files off the file system by demand or  
threshold migration, or manually migrate files. Then retry the operation.  
ANS9552E  
program-name: cannot add fsm to file-system; path includes non-local file  
system.  
Explanation: An attempt was made to add space management to a file system  
whose path contains non-local elements.  
System Action: Processing stopped.  
User Response: File system must be entirely local.  
ANS9553I  
Wrote temporary candidates list to file-name.  
Explanation: Due to out of space condition, the candidates list was written to the  
named temporary file.  
System Action: Temporary file created.  
User Response: Temporary file can be copied to the appropriate .SpaceMan  
directory when space is made available.  
ANS9554I  
Object ’dir-name’ is a directory. It is skipped for recall.  
Explanation: The object is a directory. It is not recalled. Space management does  
not migrate and recall directories.  
System Action: TSM does not recall this object.  
User Response: None.  
ANS9555W  
program-name: This TSM daemon requires cell_admin’s password to refresh its  
DCE ticket. Please enter your DCE password:  
Explanation: The DCE ticket expires after a certain time and the TSM daemons  
require cell_admin’s password to refresh their access privileges. This procedure can  
be automated by storing the password in /etc/security/adsm/dcepasswd.  
System Action: The system waits for your password.  
User Response: Enter your password.  
1296  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9556W  
ANS9557W  
ANS9559W  
ANS9561W  
program-name: Your account does not allow access to the DCE registry  
database! Aborting ...  
Explanation: Certain programs require full cell administrator privileges.  
Otherwise, the start-up permission is not granted.  
System Action: The program aborts the operation.  
User Response: Contact your cell administrator.  
program-name: It was not possible to renew the DCE ticket for an TSM  
daemon! Please restart! Aborting ...  
Explanation: There may be some situation where the TSM daemons fail to renew  
their DCE ticket (for example, if the password for cell_admin is changed).  
System Action: The program aborts the operation.  
User Response: Restart dsmmonitord and dsmrecalld with proper privileges.  
program-name: Cannot extract cell properties! Aborting ...  
Explanation: There may be some situation where it is not possible to extract  
necessary cell information (for example, if the DCE daemons are not started  
properly).  
System Action: The program aborts the operation.  
User Response: Check your DCE environment.  
program-name: Cannot extract your account information from the DCE  
registry! Aborting ...  
Explanation: There may be some situation where it is not possible to extract  
necessary account information (for example, if the DCE daemons are not started  
properly).  
System Action: The program aborts the operation.  
User Response: Check your DCE environment.  
ANS9562W  
program-name: Your account does not allow access to the DCE registry  
database! Aborting ...  
Explanation: There may be some situation where it is not possible to extract DCE  
registry information (for example, if the DCE daemons are not started properly).  
System Action: The program aborts the operation.  
User Response: Check your DCE environment.  
Tivoli Storage Manager Messages  
1297  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9563W  
program-name: The minimum certificate lifetime must be longer than 2 hours.  
Aborting ...  
Explanation: The minimum DCE ticket lifetime has to be longer than 2 hours to  
ensure that long operations have enough time to fullfill their tasks.  
System Action: The program aborts the operation.  
User Response: Set DCE ticket lifetime to a value greater than 2 hours.  
ANS9564W  
program-name: Severe problem! Cannot access the dfstab and/or filesystem list!  
Explanation: TSM requires access to the /opt/dcelocal/var/dfs/dfstab and the  
filesystem table.  
System Action: None  
User Response: Repeat operation. If the problem persists, contact your system  
and/or cell administrator.  
ANS9565W  
ANS9566W  
ANS9567W  
program-name: Severe problem! Cannot access the dfstab!  
Explanation: TSM requires access to the /opt/dcelocal/var/dfs/dfstab.  
System Action: None  
User Response: Repeat operation. If the problem persists, contact your system  
and/or cell administrator.  
program-name: Failed to analyse path path!  
Explanation: The TSM DFS HSM client works within HSM managed DCE  
environments only.  
System Action: The program aborts the operation.  
User Response: Contact your system and/or cell administrator.  
program-name: The provided password failed for the cell root account!  
Explanation: Several TSM commands require cell root privileges to perform  
security sensitive tasks. The password for the account can be supplied via  
dsmdcepasswd.  
System Action: The program aborts the operation.  
User Response: Execute dsmdcepasswd.  
1298  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9568W  
program-name: Aggregate aggregate-name is going to be DETACHED from the  
cell !!! You have 5 seconds to intervene via CTRL-C!  
Explanation: Activating HSM may require detaching aggregates from your cell to  
install DMApi support. All file operation within the aggregate will fail for this  
period.  
System Action: The system waits 5 secs before the program continues.  
User Response: Wait and grant the detachment or interrupt.  
ANS9569W  
ANS9570W  
ANS9571W  
program-name: Please specify the name of the aggregate!  
Explanation: Some programs require the name of an aggregate as a parameter.  
System Action: The program aborts the operation.  
User Response: Restart the program with an aggregate name.  
program-name: Aggregates without any fileset cannot be HSM managed!  
Explanation: An aggregate has to include at least one fileset to be HSM managed  
System Action: The program aborts the operation.  
User Response: Install at least one fileset in the aggregate.  
program-name: You must be cell root in order to execute this command.  
Aborting ...  
Explanation: The user must have the appropiate privileges to execute the  
command.  
System Action: The program aborts the operation.  
User Response: Login with the cell root account.  
ANS9572W  
program-name: All local aggregates are going to be DETACHED from the cell  
toactivate HSM management !!! You have 5 seconds to intervene via CTRL-C!  
Explanation: Activating HSM may require detaching all local aggregates from  
your cell to install DMApi support. All file operation will fail for this period.  
System Action: The system waits 5 secs before the program continues.  
User Response: Wait and grant the detachment or interrupt.  
Tivoli Storage Manager Messages  
1299  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9574W  
program-name: The minimum ticket lifetime must be 10 minutes or  
longer!Aborting ...  
Explanation: The minimum DCE ticket lifetime must be 10 minutes or longer to  
ensure that long TSM operations have enough time to fullfill their tasks.  
System Action: The program aborts the operation.  
User Response: Set minimum DCE ticket lifetime to at least 10 minutes.  
ANS9575W  
program-name: Your login context is not authorized to access necessary  
networkresources! Aborting ...  
Explanation: This may happen if it was not possible to renew a DCE login  
context.  
System Action: The program aborts the operation.  
User Response: Contact your system and/or cell administrator. Restart daemons.  
ANS9576W  
program-name: The password of cell root has expired! Please update the  
password information via dsmdcepasswd and restart the daemons. Aborting...  
Explanation: Password expiration of the cell root’s login context.  
System Action: The program aborts the operation.  
User Response: Execute dsmdcepassewd and restart daemons.  
ANS9577W  
program-name: The file or directory does not reside in an HSM managed  
aggregate: path!  
Explanation: Some of the TSM DFS HSM commands works within HSM  
managed DCE environments only.  
System Action: The program aborts the operation. The only exception is dsmls.  
User Response: Make sure that the path resides in an HSM managed aggregate.  
ANS9578W  
program-name: Cannot access the cell! You’re either not logged into the cell or  
the cell is currently down! Aborting ...  
Explanation: The program was not able to access the DFS filespace.  
System Action: The program aborts the operation.  
User Response: Make sure that you are correctly logged into the cell and/or renew  
your DCE ticket. Check whether your local DCE environment is running.  
1300  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9581W  
ANS9582W  
ANS9583W  
dsmmigfs: Severe Problem! Cannot mount a newly created fileset which is used  
for administrative HSM purposes. DFS may be inconsistent here! Aborting ...  
Explanation: dsmmigfs was not able to create and mount a fileset within its  
administrative structure.  
System Action: dsmmigfs aborts the operation.  
User Response: The cell’s behaviour is inconsistent here. Reinitialize DFS.  
program-name: Severe Problem! Cannot access the DFS root directory!  
Aborting ...  
Explanation: The DFS root directory “/:/” or /.../cellname/fs was not accessible  
System Action: The program aborts the operation.  
User Response: The aggregate inhibiting the root fileset, or the root fileset itself  
has not been exported. Contact your cell administrator.  
program-name: The size of this aggregate is too small. Use aggregates larger  
than 100MB. The administrative HSM structure is relatively large for the  
specified size of only number MB.  
Explanation: The size of this aggregate is too small. The administrative HSM  
structure is relatively large for the specified size of the aggregate.  
System Action: The program aborts the operation.  
User Response: Use aggregates larger than 100MB.  
ANS9596W  
program-name: The selected aggregate is not yet enabled for Data Management!  
Please perform the following steps prior to this command: 1. dfsexport -detach  
-aggregate aggregate name 2. Edit /opt/dcelocal/var/dfs/dfstab and change the  
filessystem type of aggregate aggregate name from lfs to dmlfs 3.  
/usr/lpp/dce/bin/dmaggr -aggregate aggregate name -on 4. dfsexport -aggregate  
aggregate name Please be aware of the DCE usage restrictions on DM enabled  
aggregates!  
Explanation: HSM managed aggregates have to be DM enabled.  
System Action: The program aborts the operation.  
User Response: Perform the changes and restart the command. See manual for  
details.  
Tivoli Storage Manager Messages  
1301  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9597W  
program-name: The selected aggregate is still enabled for Data Management!  
There are DCE usage restriction on DM enabled aggregates which can be  
disabled by performing the following steps: 1. dfsexport -detach -aggregate  
aggregate name 2. Edit /opt/dcelocal/var/dfs/dfstab and change the filessystem  
type of aggregate aggregate name from dmlfs to lfs 3. /usr/lpp/dce/bin/dmaggr  
-aggregate aggregate name -off 4. dfsexport -aggregate aggregate name  
Explanation: After removing HSM from an aggregate, the DM attribute should be  
set to its normal value.  
System Action: None  
User Response: Perform the changes. See manual for details.  
ANS9598W  
ANS9599W  
ANS9600W  
The specified aggregate is now enabled for HSM. However, you still have to  
define one or more fileset mount points using the VIRTUALMOUNTPOINT  
option in order to activate data management.  
Explanation: A user has to define VIRTUALMOUNTPOINTS just like an include  
list. Based on this path information, HSM will scan the aggregate for candidates.  
System Action: None  
User Response: Specify VIRTUALMOUNTPOINTS for the filesets of an  
aggregate which should be activated for data management.  
The specified path file path does not match any defined  
VIRTUALMOUNTPOINT.  
Explanation: A user has to define VIRTUALMOUNTPOINTs to enable certain  
paths for HSM. A VIRTUALMOUNTPOINT is only valid for the corresponding  
parent fileset.  
System Action: None  
User Response: Specify VIRTUALMOUNTPOINTs in dsm.opt for all the filesets  
of an aggregate which should be activated for data management.  
The option file does not contain any VIRTUALMOUNTPOINTS for aggregate  
DFS aggregate.  
Explanation: A user has to define VIRTUALMOUNTPOINTs just like an include  
list. Based on these path information, HSM will scan the aggregate for candidates.  
System Action: None  
User Response: Specify VIRTUALMOUNTPOINTs in dsm.opt for the filesets of  
an aggregate which should be activated for data management.  
1302  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9601W  
ANS9602W  
ANS9603W  
program-name: The file DFS file was accessed less than an hour ago so it is not  
qualified for migration. File is skipped.  
Explanation: Due to synchronization requirements by the DFS environment a file  
should not be migrated until it has reached a certain age.  
System Action: The program continues.  
User Response: Wait at least an hour when the file is not accessed, then repeat the  
operation.  
program-name: The TSM daemons require certain rights in order to access data  
within the DFS filespace. Please enter an appropiate DCE account that has  
general access to the data that should be under HSM control. Please enter the  
DCE account:  
Explanation: see message text.  
System Action: The program prompts for login.  
User Response: Enter DCE login.  
program-name: The TSM daemons require cell root access rights for the DFS  
filespace. After entering the password, TSM will encrypt it and store the result  
to /etc/security/adsm/dcepasswd. Enter cell root’s password:  
Explanation: See message.  
System Action: The program prompts for password.  
User Response: Enter DCE passwd.  
ANS9604W  
program-name: Encrypting ... Done. Please make sure to repeat this procedure  
as soon as you update the password in the DCE world!  
Explanation: Information.  
System Action: None.  
User Response: None.  
ANS9605E  
program-name: The daemon was not able to start the DCE ticket refresh thread.  
There may be a problem with the DCE security server.  
Explanation: A DCE ticket can expire unless a refresh thread cares about the  
ticket update.  
System Action: The program aborts.  
User Response: Make sure that DCE security server is running.  
Tivoli Storage Manager Messages  
1303  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9607E  
program-name: Aggregate aggregate-name is either not exported or not  
initialized for LFS! Aborting!  
Explanation: The target aggregate must be exported before adding it to HSM.  
System Action: The program aborts.  
User Response: Attach the aggregate.  
ANS9608E  
program-name: Unable to load an LFS Kernel extension! Aborting!  
Explanation: HSM needs special kernel extensions in order to run. DCE is either  
not yet fully up, or there is a problem with the DCE configuration or installation.  
System Action: The program aborts.  
User Response: Wait till DCE is fully up. Then try to run /usr/sbin/cfgdfs -a  
/usr/lib/drivers/dcelfs.ext. If you don’t see any output, everything is running  
correctly. Otherwise there is a severe problem in your DCE environment.  
ANS9609E  
program-name: Unable to load an DMEpi Kernel extension! Aborting!  
Explanation: HSM needs special kernel extensions in order to run. DCE is either  
not yet fully up, or there is a problem with the DCE configuration or installation.  
System Action: The program aborts.  
User Response: Wait till DCE is fully up. Then try to run /usr/sbin/cfgdmepi -a  
/usr/lib/drivers/dmlfs.ext. If you don’t see any output, everything is running  
correctly. Otherwise there is a severe problem in your DCE environment.  
ANS9610E  
program-name: Unable to update the state of aggregate aggregate-name in the  
dfstab! Aborting!  
Explanation: HSM needs to toggle the filesystem type of the target aggregate in  
/opt/dcelocal/var/dfs/dfstab. This operation failed.  
System Action: The program aborts.  
User Response: Detach the aggregate from the cell by executing dfsexport  
-detach AggregateName. Edit /opt/dcelocal/var/dfs/dfstaband toggle the type of  
the target aggregate. If you add HSM to the aggregate you should toggle lfsto  
dmlfs. Execute /usr/lpp/dce/bin/dmaggr AggregateName -on. If you remove  
HSM from the aggregate you should toggle dmlfsto lfs. Execute  
/usr/lpp/dce/bin/dmaggr AggregateName -off. Then dfsexport the aggregate again.  
1304  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9611W  
program-name: It was not possible to set the correct DCE thread policy.  
Explanation: The program tried to set an appropiate thread policy for the DCE  
ticket refresh thread.  
System Action: The program aborts.  
User Response: Try to restart the HSM daemons. If this does not work there is  
probably a problem in the system. A reboot may be necessary in this case.  
ANS9613E  
ANS9641S  
ANS9732E  
ANS9733E  
program-name: Stubsize of stubsize bytes is not supported on filesystem.  
Explanation: The given stubsize value not a multiple of the file system blocksize  
and cannot be supported.  
System Action: The program aborts the operation.  
User Response: Use a correct stub size.  
Invalid option ’option’ found in options file ’file-name’ at line number : number  
Invalid entry : ’entry’  
Explanation: The specified option in the TSM options file (file-name) is in error.  
System Action: Processing stopped.  
User Response: Correct the options file entry.  
No Backup Copy Group for Management Class: management-class  
Explanation: The management class for this file does not have a backup copy  
group specified.  
System Action: Processing stopped.  
User Response: See your system administrator.  
File: File-name excluded by the Include/Exclude list  
Explanation: You tried to back up the named file-name that was specified to be  
excluded from backup.  
System Action: TSM did not back up the file.  
User Response: Specify the file using the Include option and retry the operation.  
Tivoli Storage Manager Messages  
1305  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9734E  
There are number file(s) not selected. Click on file to find out reason.  
Explanation: There are files that cannot be selected.  
System Action: These files will not be selected for migrate or recall.  
User Response: Click on the files to find out the reason these files are not  
selected, for example, inclexcl list.  
ANS9735E  
Error doing realtime initialization  
Explanation: TSM ran out of resource (either processes or shared storage) that  
prevents it from starting a migrate or recall operation. Your file selections remain  
intact.  
System Action: TSM cannot start the migrate or recall operation.  
User Response: Retry the operation. If unsuccessful, see your system  
administrator.  
ANS9736E  
ANS9737E  
ANS9738S  
Not enough memory for authorization list table  
Explanation: TSM cannot allocate enough storage for the authorization list.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If unsuccessful, see your system  
administrator.  
Authentication failed -- Exit TSM to retry  
Explanation: You typed an incorrect password four times in a row.  
System Action: TSM cannot connect to the server without a correct password.  
User Response: Exit and restart TSM if authorized; otherwise, see your system  
administrator.  
Out of memory  
Explanation: TSM found an error allocating storage at initialization.  
System Action: TSM cannot continue.  
User Response: See your system administrator.  
1306  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9739E  
Cannot get shared memory  
Explanation: The system ran out of shared storage resources.  
System Action: TSM cannot continue without a shared storage segment.  
User Response: Check the output of the “ipcs” program to see if there are many  
new shared storage segments. Use “ipcrm” to remove them. If this problem  
continues, configure UNIX to allow more shared storage segments.  
ANS9740S  
This program is not installed correctly. Please place the application defaults file  
(file-name) into the application default directory (usually directory-name), or set  
the XAPPLRESDIR environment variable to the directory containing the  
file-name defaults file.  
Explanation: TSM cannot find its resource file (Sm) in the default directory  
(directory-name). A problem may have occurred during installation.  
System Action: TSM cannot start.  
User Response: See your system administrator.  
ANS9741E  
Not enough memory to hold directory structure  
Explanation: TSM cannot allocate storage for the requested directory structure.  
This error can happen under migrate or recall operations.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If unsuccessful, see your system  
administrator.  
ANS9742E  
Error reading directory structure  
Explanation: TSM cannot load the requested directory structure. This error is due  
to a corrupted file system or a storage shortage. This can happen under selective  
migrate or selective recall.  
System Action: TSM cannot complete the requested operation.  
User Response: Retry the operation. If unsuccessful, see your system  
administrator.  
ANS9743W  
No files selected in directory tree  
Explanation: You did not select any files to list for migrate or recall.  
System Action: TSM cannot complete the requested operation.  
User Response: Select files and retry the operation.  
Tivoli Storage Manager Messages  
1307  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9744W  
Size exceeds limit  
Explanation: You tried to recall a file that has exceeded the maximum file size  
limitation on your system.  
System Action: TSM cannot recall the file.  
User Response: Recall this file on a system that supports the file size. See your  
system administrator.  
ANS9790I  
File is skipped for migration: No backup copy found.  
Explanation: A management class is assigned to the file with the attribute  
MIGREQUIRESBKUP set to YES. This requires a current backup copy of the file  
before migration. However, there is no backup copy found on the migration server.  
This file will not be migrated. Note: TSM checks only the migration server for a  
backup copy. If the migration server and backup server are different servers, TSM  
does not find a backup copy of the file.  
System Action: TSM does not migrate this file.  
User Response: Back up this file on the migration server, or assign a management  
class to this file that does not require a current backup copy. Retry the operation.  
ANS9791I  
File is skipped for migration: Backup copy found is not current.  
Explanation: A management class is assigned to the file with the attribute  
MIGREQUIRESBKUP set to YES. This requires a current backup copy of the file  
before migration. However, the backup copy found on the migration server is an old  
version. This file will not be migrated. Note: TSM checks only the migration server  
for a backup copy. If the migration server and backup server are different servers,  
there must be a valid backup copy of the file on the migration server.  
System Action: TSM does not migrate this file.  
User Response: Back up the current file on the migration server, or assign a  
management class to this file that does not require a current backup copy. Retry the  
operation.  
ANS9792W  
A tree view of a file system is being built. Please wait until it completes, and  
then retry the operation.  
Explanation: You tried to choose Selective Migration or Selective Recall when a  
tree view of a file system is being built.  
System Action: TSM ignores the request.  
User Response: Wait until the tree view build completes, and then retry the  
operation.  
1308  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9796E  
Cannot access lock file for file-system file system.  
Explanation: TSM cannot access a lock file due to an error. The lock file provides  
serialization of certain programs to prevent conflicting processes from running at the  
same time.  
System Action: TSM will not run the program at this time.  
User Response: Check the permissions on the directories leading up to the lock  
file and also the permissions on the program executable.  
ANS9797E  
A conflicting space management process is already running in the file-system  
file system. Rerun this process at a later time.  
Explanation: TSM detects that another process that conflicts with the process you  
are trying to run is running in the file system. The following processes cannot be  
run at the same time for a file system:  
dsmreconcile  
dsmautomig  
dsmmigfs remove.  
Also dsmmigfs remove cannot run while a migration process is running in the file  
system.  
System Action: TSM will not run the process at this time.  
User Response: Try running the process again later.  
ANS9799W  
Cannot open temp file for mount command.  
Explanation: TSM cannot open a temporary file to process the mount command  
for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
ANS9800W  
Cannot create temp file for mount command.  
Explanation: TSM cannot create a temporary file to process the mount command  
for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
Tivoli Storage Manager Messages  
1309  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9801W  
ANS9802W  
ANS9803W  
ANS9804W  
ANS9805W  
ANS9806W  
Cannot create transaction file.  
Explanation: Cannot create transaction file for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
Cannot create status file.  
Explanation: Cannot create status file for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
Cannot create premigration database.  
Explanation: Cannot create a premigration database for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
Cannot create migration candidates list.  
Explanation: Cannot create a migration candidates list for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
Cannot create .SpaceMan directory.  
Explanation: Cannot create .SpaceMan directory for this file system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
File system type is not supported.  
Explanation: The file system is not a type supported by space management.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
1310  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9808W  
Invalid field in the dsmmigfstab file.  
Explanation: There is an invalid field in the dsmmigfstab file entry for the file  
system.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
ANS9809W  
ANS9811W  
ANS9812I  
Cannot open the dsmmigfstab file.  
Explanation: TSM cannot open the dsmmigfstab file.  
System Action: TSM cannot add space management to the file system.  
User Response: Check with the system administrator.  
Server did not respond. Check the server connection. Select OK to exit.  
Explanation: Server did not respond.  
System Action: TSM stops processing.  
User Response: Exit dsmhsm. Check the server connection and try again later.  
Files not found in current directory. Refresh file systems.  
Explanation: Some files are not found in the local file system.  
System Action: The transaction will show incorrect results.  
User Response: Refresh the file systems to reflect local file systems.  
ANS9813W  
Incorrect data shown. Run reconcile.  
Explanation: Information in the space management status file is not synchronized  
with the file system.  
System Action: TSM continues processing.  
User Response: To correct the information, run reconcile, and then refresh the  
current window.  
ANS9814W  
Cannot create migration object ID.  
Explanation: The file system is full. No more free space can be allocated for the  
migration object ID when a file is being migrated or recalled.  
System Action: TSM terminates the current operation for this file system.  
Tivoli Storage Manager Messages  
1311  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Remove some files in the file system, and then run reconciliation.  
Retry the operation.  
ANS9815W  
Out of free space or inodes in file system to migrate or recall.  
Explanation: The file system is full. No more free space or free inodes are  
available to be allocated for the transaction file that is needed when a file is being  
migrated or recalled.  
System Action: TSM terminates the current operation for this file system.  
User Response: Remove some files in the file system, and then run reconciliation.  
Retry the operation.  
ANS9816W  
File system has exceeded its quota.  
Explanation: TSM detects that the file system has exceeded its quota. No more  
files can be migrated to TSM storage for this file system.  
System Action: TSM will not migrate files from this file system.  
User Response: Either recall some files to the local file system, or ask the system  
administrator to increase the quota for this file system.  
ANS9817W  
file-system is globally deactivated. Please wait until the file system is globally  
reactivated.  
Explanation: The file system is in a global inactive state.  
System Action: TSM cannot continue the process.  
User Response: Wait until the system administrator globally reactivates the file  
system.  
ANS9818W  
A selective recall is in progress. Stop the recall, and then close the window.  
Explanation: You tried to close the Selective Recall Status window while a  
selective recall was in progress.  
System Action: TSM ignores the request.  
User Response: Stop the selective recall process, and then close the window.  
ANS9819W  
A selective migration is in progress. Stop the process, and then close the  
window.  
Explanation: You tried to close the Selective Migration Status window while a  
selective migration was in progress.  
1312  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM ignores the request.  
User Response: Stop the selective migration process, and then close the window.  
ANS9820W  
A selective recall or a selective migration is in progress. Wait until it completes,  
and then retry the operation.  
Explanation: You tried to perform one of the following while a selective recall or  
selective migration process was in progress:  
Add space management  
Deactivate or reactivate space management  
Global deactivate or reactivate space management  
Display policy information  
Change password  
System Action: TSM ignores the request.  
User Response: Wait until the selective recall or selective migration process is  
complete, and then retry the operation.  
ANS9821W  
ANS9822W  
ANS9823W  
ANS9824W  
New password is not re-entered.  
Explanation: You did not re-enter the new password.  
System Action: The Change password dialog will display again.  
User Response: Re-enter the new password.  
New password is not entered.  
Explanation: You did not enter the new password.  
System Action: The Change password dialog will display again.  
User Response: Enter the new password.  
Current password is not entered.  
Explanation: You did not enter the current password.  
System Action: The Change password dialog will display again.  
User Response: Enter the current password.  
Cannot update space management settings for file-system  
Explanation: You tried to update space management settings for a file system, and  
the update failed.  
System Action: TSM continues with normal operation.  
Tivoli Storage Manager Messages  
1313  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check with the system administrator.  
ANS9825W  
Total migrated space is greater than quota for file system.  
Explanation: TSM total migrated space is greater than quota.  
System Action: TSM continues.  
User Response: You can remove this warning message by increasing the quota for  
the file system.  
ANS9827W  
Error accessing the Recall daemon lock file: file name.  
Explanation: There is a problem accessing the recall daemon lock file.  
System Action: TSM cannot determine whether the recall daemon is running.  
Because the recall daemon is needed to perform file recalls, the recall fails.  
User Response: Check with the system administrator. The recall process needs  
read access to the /etc/adsm/SpaceMan/dsmrecalld.pid file.  
ANS9828W  
ANS9829W  
ANS9830W  
Error processing the space monitor daemon: reason.  
Explanation: There is a problem accessing the space monitor daemon.  
System Action: TSM cannot perform automatic space management functions.  
User Response: Check with the system administrator. The space monitor daemon  
is normally installed as /usr/lpp/adsm/bin/dsmmonitord.  
Recall daemon is not running.  
Explanation: An TSM recall daemon is not running.  
System Action: TSM recall fails.  
User Response: Ask the system administrator to start a recall daemon by issuing  
the dsmrecalld command.  
Space monitor daemon is not running.  
Explanation: The space monitor daemon is not running.  
System Action: TSM is unable to perform space management functions.  
User Response: Ask the system administrator to start the space monitor daemon  
by issuing the dsmmonitord command.  
1314  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9840W  
Cannot open /dev/fsm.  
Explanation: While attempting to add space management to a file system, TSM  
was unable to open the /dev/fsm device, which is the space management (hsm)  
device driver.  
System Action: TSM terminates the requested process and returns to normal  
operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9841E  
ANS9842E  
ANS9843E  
Cannot get user name for the user ID.  
Explanation: TSM cannot get the user name for the user ID.  
System Action: TSM terminates the requested process and returns to normal  
operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
Cannot refresh local file space information.  
Explanation: TSM cannot refresh local file space information.  
System Action: TSM terminates the requested process and returns to normal  
operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
Cannot connect to migration server.  
Explanation: TSM cannot connect to the migration server specified in your client  
system options file.  
System Action: TSM terminates the requested process and returns to normal  
operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9844E  
Cannot close the premigrated files database.  
Explanation: TSM cannot close the premigrated files database for the file system.  
The premigrated files database resides in the .SpaceMan subdirectory of the file  
system’s root directory.  
Tivoli Storage Manager Messages  
1315  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM terminates the requested process, and returns to normal  
operation.  
User Response: Retry the operation. If the problem continues, check with your  
system administrator.  
ANS9846W  
ANS9848W  
Cannot add space management to file system.  
Explanation: TSM cannot add space management to the file system.  
System Action: TSM continues with normal operation.  
User Response: Check with the system administrator.  
Cannot activate file system file system.  
Explanation: TSM cannot activate space management for the specified file  
system.  
System Action: TSM file system state is not changed.  
User Response: Check with your system administrator.  
ANS9849W  
ANS9850E  
ANS9851E  
A error occurred while refreshing the pie chart information for file system. Data  
is not updated.  
Explanation: An error occurred while refreshing pie chart information.  
System Action: TSM pie chart information is not updated.  
User Response: Check with your system administrator.  
The view book program is already running on your desktop.  
Explanation: The view book program has already been launched and is still  
running.  
System Action: TSM continues with normal operation.  
User Response: Check your desktop for the running view book program.  
Cannot find the view book program. Double check the BOOKS option in your  
client user options file.  
Explanation: The space management GUI client failed to execute the program you  
specified with the BOOKS option in your client user options file.  
System Action: TSM continues with normal operation.  
1316  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check to make sure the PATH environment variable contains the  
path to the program, or double check the BOOKS option to make sure the name is  
correct.  
ANS9852E  
ANS9853W  
ANS9854W  
ANS9855W  
Cannot query the level of client and kernel.  
Explanation: The space management GUI client fails to query the level of kernel  
and client code.  
System Action: TSM continues with normal operation.  
User Response: Check with your system administrator.  
The space management client program is downlevel.  
Explanation: The space management client is downlevel compared to the kernel  
level.  
System Action: TSM continues with normal operation.  
User Response: Check with your system administrator.  
The space management kernel is downlevel.  
Explanation: The space management kernel is downlevel compared to the client  
level.  
System Action: TSM continues with normal operation.  
User Response: Check with your system administrator.  
File is accessed during migration. File skipped.  
Explanation: The specified file-name was not migrated because the file was  
accessed by another process during the attempt to migrate it.  
System Action: TSM left the file resident.  
User Response: If you want the file migrated, stop the process which is accessing  
the file and retry the migration operation.  
ANS9856E  
File is currently opened by another process. File skipped. File has already been  
migrated or is currently being migrated by another process.  
Explanation: The specified file was not migrated because the file was opened by  
one or more other processes.  
System Action: TSM left the file resident.  
Tivoli Storage Manager Messages  
1317  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If you want the file migrated, stop the processes which currently  
have the file open, and retry the migration operation.  
ANS9857E  
View Books requires BOOKS option in the options file.  
Explanation: The BOOKS option is not specified in your client user options file  
(dsm.opt).  
System Action: TSM continues with normal operation.  
User Response: Add a BOOKS option specifying the executable name of the  
online book reader and the name of the TSM Bookshelf. Then, retry the operation.  
ANS9858E  
Bit file for image on push button cannot be found. Please check to make sure  
the pixmap file exists in your TSM installed directory.  
Explanation: TSM failed to find the pixmap file defined for the push button.  
System Action: TSM continues with normal operation.  
User Response: Check to see whether the pixmap file exists in the TSM  
installation directory.  
ANS9859E  
Cannot get information for filespace file space: reason.  
Explanation: Error encountered when system reads common attributes about the  
file space.  
System Action: TSM cannot read file space attributes.  
User Response: Check with your system administrator.  
ANS9860W  
Some selected files are hidden. Change View option to see all.  
Explanation: You have selected all files in a directory or in all subdirectories. Due  
to the current View option, only certain types of files are shown (either migrated,  
resident, or premigrated files).  
System Action: TSM proceeds normally.  
User Response: If you want to see all selected files, change the View option from  
the View menu bar option.  
ANS9862W  
Do you want to exit TSM space management?  
Explanation: You have selected Exit from the File menu bar option.  
System Action: TSM waits for your response.  
1318  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: If you want to exit the program, select OK. Otherwise, select  
Cancel.  
ANS9871W  
Specified column width is smaller than the largest attribute value. Data will be  
truncated.  
Explanation: You have entered a column width that is too small to display all  
digits of the largest attribute.  
System Action: TSM accepts your request.  
User Response: To see all attributes in full length, increase the column width.  
ANS9872W  
Remove is in progress. Requested operation is not allowed.  
Explanation: A remove process is in progress. You have requested an operation  
that is not allowed when a remove process is in progress.  
System Action: TSM continues with normal operation.  
User Response: Wait until the remove process completes, and then retry the  
operation.  
ANS9873W  
This function should not be used on large file systems. Continue anyway ?  
Explanation: You have decided to open selective recall or selective migration  
window, but these functions may take too long for large file systems.  
System Action: TSM waits for your response.  
User Response: If you want to continue, select OK. Otherwise, select Cancel.  
ANS9875W  
Refresh time must be numeric value and within 0 - 14400 minutes or 0 - 240  
hours (10 days).  
Explanation: You have entered an invalid value for Refresh time. It must be a  
positive number between 0 and 14400.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 14400.  
ANS9876W  
Refresh time must be a positive number.  
Explanation: You have entered an invalid value for Refresh time. It must be a  
positive number between 0 and 14400.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 14400.  
Tivoli Storage Manager Messages  
1319  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9877W  
ANS9878W  
ANS9879W  
ANS9880W  
ANS9881W  
ANS9882W  
Size Factor must be a numeric value between 0 - 999999999.  
Explanation: You have entered an invalid value for Size Factor. It must be a  
positive number between 0 and 999999999.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 999999999.  
Size Factor must be a positive number.  
Explanation: You have entered an invalid value for Size Factor. It must be a  
positive number between 0 and 999999999.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 999999999.  
Age Factor must be a numeric value between 0 - 999999999.  
Explanation: You have entered an invalid value for Age Factor. It must be a  
positive number between 0 and 999999999.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 999999999.  
Age Factor must be a positive number.  
Explanation: You have entered an invalid value for Age Factor. It must be a  
positive number between 0 and 999999999.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 999999999.  
Premigration Percent must be a numeric value between 0 - 100.  
Explanation: You have entered an invalid value for Premigration Percentage. It  
must be a positive number between 0 and 100.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 100.  
Premigration Percent must be a positive number.  
Explanation: You have entered an invalid value for Premigration Percentage. It  
must be a positive number between 0 and 100.  
1320  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 100.  
ANS9883W  
ANS9884W  
ANS9885I  
Quota must be a numeric value between 0 - 999999999.  
Explanation: You have entered an invalid value for Quota. It must be a positive  
number between 0 and 999999999.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 999999999.  
Quota must be a positive number.  
Explanation: You have entered an invalid value for Quota. It must be a positive  
number between 0 and 999999999.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 999999999.  
The premigration percentage will not be updated until you select the Update  
push button on the Update window or the Add push button on the Add  
window.  
Explanation: While you have just selected 'OK' in the Advanced Feature dialog,  
the premigration percentage is not activated until you select 'Add' or 'Update' in the  
'Add space management', or the 'Update space management' dialog.  
System Action: TSM waits until you select 'Add' or 'Update' to apply your  
premigration percentage to the system.  
User Response: When you have changed the space management attribute, select  
'Add' or 'Update', and then the system will apply your new premigration percentage.  
ANS9886W  
Enter a positive number for Column Width.  
Explanation: You have entered an invalid value for Column Width. It must be a  
positive number between 0 and 18.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 18.  
ANS9887W  
Enter a positive number for Space Between Column.  
Explanation: You have entered an invalid value for Space Between Column. It  
must be a positive number between 0 and 18.  
Tivoli Storage Manager Messages  
1321  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM continues with normal operation.  
User Response: Enter a positive number between 0 and 18.  
ANS9889W  
Space management has not been added to file-system file system. Do you want  
to build the directory tree anyway?  
Explanation: You selected a file system that is not managed by HSM.  
System Action: TSM builds the directory tree if you select the OK button.  
Otherwise, it will not.  
User Response: You can add space management to the file system by selecting the  
Space Manager push button in the TSM main window, and then selecting Add under  
the Selected menu option.  
ANS9891W  
ANS9895W  
Please mark either or both check boxes before proceeding.  
Explanation: You have not marked either of the check boxes.  
System Action: TSM does not proceed with reconcile processing.  
User Response: Mark either or both check boxes.  
Space management in file system file system is not active.  
Explanation: You tried to select a file in a file system for which space  
management is inactive.  
System Action: TSM continues with normal operation.  
User Response: Reactivate space management for the file system, and then  
proceed with selecting files.  
ANS9899E  
ANS9900E  
Cannot recall resident or premigrated file.  
Explanation: The file is a resident or premigrated file.  
System Action: The file is not selected.  
User Response: Select only migrated files for recall.  
FSM kernel extension not installed.  
Explanation: The file system selected is not fully activated. The system received  
an error trying to open /dev/fsm.  
System Action: TSM operation stops.  
1322  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check to see whether /dev/fsm entry exists, and check space  
management installation.  
ANS9901E  
Cannot migrate TSM system internal file.  
Explanation: You tried to select files that are used internally by the HSM client.  
You cannot migrate TSM internal files.  
System Action: TSM ignores your request.  
User Response: None.  
ANS9903E  
Space management is deactivated for this file system.  
Explanation: You tried to migrate a file in a file system for which space  
management is inactive.  
System Action: TSM continues to migrate files only in active file systems.  
User Response: Reactivate space management for the file system, and retry the  
migration operation.  
ANS9904E  
Transaction failed, migration aborted.  
Explanation: The specified file-name was not migrated because the file was  
accessed by another process during the attempt to migrate it.  
System Action: TSM migration is aborted.  
User Response: If you want the file migrated, stop the process that is accessing  
the file, and then retry the migration.  
ANS9908E  
ANS9909I  
System Error.  
Explanation: TSM detects an error in reading the state of the file system.  
System Action: TSM proceeds with normal operation.  
User Response: Report the error to your system administrator.  
Error in accessing migration candidates list file.  
Explanation: TSM detects an error in reading the migration candidates list file.  
This file resides in the .SpaceMan directory of the file system.  
System Action: TSM proceeds with normal operation.  
User Response: Report the error to your system administrator.  
Tivoli Storage Manager Messages  
1323  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9914I  
Space management settings have been modified successfully on file-system file  
system.  
Explanation: Space management settings have been updated successfully.  
System Action: TSM updated space management settings for the file system.  
User Response: Continue with normal operation.  
ANS9915I  
ANS9916I  
ANS9918E  
Space management has been added successfully to file-system file system.  
Explanation: Space management has been added successfully.  
System Action: TSM added and activated space management for the file system.  
User Response: Continue with normal operation.  
Space management successfully activated file-system file system.  
Explanation: Space management has been activated successfully.  
System Action: TSM activated space management for the file system.  
User Response: Continue with normal operation.  
Cannot open migration candidates list for file-system.  
Explanation: TSM cannot access the migration candidates list for the specified file  
system.  
System Action: TSM continues normal operation.  
User Response: Select OK to return.  
ANS9919I  
ANS9928I  
Space management successfully removed from file-system file system.  
Explanation: Space management is removed successfully.  
System Action: TSM removed space management from a file system.  
User Response: Select OK to return.  
Space management has been deactivated successfully on file-system file system.  
Explanation: Space management is deactivated successfully.  
System Action: TSM deactivated space management for the file system.  
User Response: Select OK to return.  
1324  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9929I  
ANS9933I  
Space management has been reactivated successfully on file-system file system.  
Explanation: Space management is reactivated successfully.  
System Action: TSM reactivated space management for the file system.  
User Response: Select OK to return.  
Migration candidates list only exists in an ’Active’ file system. If you want to  
make file-system file system ’Active’, select ’Add Space Management’.  
Explanation: You tried to display the migration candidates list for a “Native” file  
system (a file system to which space management has not been added).  
System Action: Processing stopped.  
User Response: Select OK to return. Select “Add Space Management” if you want  
to add space management to the file system.  
ANS9934I  
ANS9935I  
ANS9936I  
Reconcile only works on an ’Active’ file system. If you want to make file-system  
file system ’Active’, select ’Add Space Management’.  
Explanation: You tried to start reconciliation on a “Native” file system (a file  
system to which space management has not been added). You must add space  
management to a file system before starting reconcile.  
System Action: Processing stopped.  
User Response: Select OK to return. Select “Add” if you want to add space  
management to the file system.  
Start Threshold Migration only works on an ’Active’ file system. If you want to  
make file-system file system ’Active’, select ’Add Space Management’.  
Explanation: You tried to start Threshold Migration on a “Native” file system (a  
file system to which space management has not been added). You must add space  
management to the file system first.  
System Action: Processing stopped.  
User Response: Select OK to return. Select “Add” if you want to add space  
management to the file system.  
Start Threshold Migration only works on an ’Active’ file system. If you want to  
make file-system file system ’Active’, select ’Reactivate’.  
Explanation: You tried to start Threshold Migration on an “Inactive” file system  
(a file system for which space management has been deactivated). You must  
reactivate space management for your file system first.  
Tivoli Storage Manager Messages  
1325  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing stopped.  
User Response: Select OK to return. Select 'Reactivate' to reactivate space  
management for the file system.  
ANS9938I  
Space management has not been added to file-system file system. You do not  
need to deactivate space management.  
Explanation: You tried to deactivate space management on a file system to which  
space management has not been added.  
System Action: Processing stopped.  
User Response: Select OK to return.  
ANS9939I  
ANS9940I  
ANS9941I  
file-system file system has already been deactivated.  
Explanation: You tried to deactivate space management for a file system that is  
already deactivated.  
System Action: Processing stopped.  
User Response: Select OK to return.  
file-system file system has already been activated.  
Explanation: You tried to activate space management for a file system that is  
already activated.  
System Action: Processing stopped.  
User Response: Select OK to return.  
Space management has not been added to file-system. If you want to add space  
management, select ’Add space management’ option. The file system will  
automatically be activated when you add space management.  
Explanation: You tried to activate space management on a file system to which  
space management has not been added. You must first add space management. The  
file system will automatically be activated when the add process is complete.  
System Action: Processing stopped.  
User Response: Select OK to return. Select “Add” if you want to add space  
management to the file system.  
1326  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9942S  
Space management has not been added to file-system file system. Do you want  
to add space management now?  
Explanation: You tried to update space management settings for a file system to  
which space management has not been added.  
System Action: Processing stopped.  
User Response: Select OK to add space management to the file system. Select  
Cancel to return.  
ANS9943I  
Space management has already been added to file-system file system.  
Explanation: You tried to add space management to a file system to which space  
management has already been added.  
System Action: Processing stopped.  
User Response: Select OK to return.  
ANS9944I  
Space management has been deactivated on file-system file system. You must  
reactivate space management before you can remove it.  
Explanation: You tried to remove space management from a file system for which  
space management has been deactivated. You must reactivate space management for  
the file system before you can remove it.  
System Action: Processing stopped.  
User Response: Select OK to return. Select “Reactivate”, and then select  
“Remove” to remove space management.  
ANS9945I  
Space management has not been added to file-system file system. You do not  
need to remove space management.  
Explanation: You tried to remove space management from a file system to which  
space management has not been added.  
System Action: Processing stopped.  
User Response: Select OK to return.  
ANS9947E  
File: file-spec is in a file system to which space management has not been  
added.  
Explanation: You tried to migrate a file that resides in a file system to which  
space management has not been added.  
System Action: TSM will not highlight/process the file.  
Tivoli Storage Manager Messages  
1327  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Switch over to the Space Manager window, and add space  
management to the file system.  
ANS9948E  
File: file-spec size is less than the minimum size required for migration.  
Explanation: You tried to migrate a file that is smaller than the minimum size  
required for migration. To be eligible for migration, a file must be larger than both  
the stub file size specified for the file system plus one byte and the block size  
defined for the file system.  
System Action: TSM will not highlight the file.  
User Response: None.  
ANS9949E  
File: file-spec is not a regular file and therefore not qualified for migration.  
Explanation: You tried to migrate a file that is not a regular file. It might be a  
FIFO file, a special file, a directory or a symbolic link.  
System Action: TSM will not highlight the file.  
User Response: None.  
ANS9950E  
File: file-spec is not qualified for migration because the Space Management  
Technique attribute is set to None.  
Explanation: The Space Management Technique attribute in the management class  
is set to None, which does not allow a file to be migrated.  
System Action: TSM will not highlight the file.  
User Response: Assign a management class to the file that specifies “Automatic”  
or “Selective” for the Space Management Technique attribute.  
ANS9951E  
ANS9953E  
File: file-name file has already been migrated.  
Explanation: You tried to migrate a file that is already migrated.  
System Action: TSM will not highlight the file.  
User Response: None.  
The management class assigned to this file does not allow migration.  
Explanation: The management class assigned to this file does not allow migration.  
System Action: TSM does not migrate the file.  
User Response: None.  
1328  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS9954E  
ANS9956E  
ANS9957E  
ANS9958E  
This file has already been migrated.  
Explanation: The file has been previously migrated.  
System Action: File is skipped.  
User Response: None.  
File is not readable.  
Explanation: You attempted to migrate a non-readable file.  
System Action: TSM skips this file and continues with the next file.  
User Response: Continue with normal operation.  
Unknown file type cannot be migrated.  
Explanation: You attempted to migrate an unknown type of file.  
System Action: TSM skips this file and continues with the next file.  
User Response: Continue with normal operation.  
File ’file-namefile-namefile-name has not yet reached the age for migration. File  
skipped.  
Explanation: This file cannot be migrated because it has not yet reached the age  
for migration.  
System Action: TSM will not highlight the file.  
User Response: None.  
ANS9960W  
No files selected for migrate or recall.  
Explanation: You requested a migrate or recall operation without selecting files  
from the presented directory tree.  
System Action: TSM cannot do the migration or recall without selected files.  
User Response: Select the files that you want to migrate or recall, and retry the  
operation.  
ANS9961E  
Server out of migrate data storage space.  
Explanation: The server ran out of space in its migrate data storage.  
System Action: TSM cannot complete the migrate operation. Any files displayed  
in the Successful list of the Migrate Status window were successfully migrated.  
Tivoli Storage Manager Messages  
1329  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check with your system administrator.  
ANS9962I  
ANS9963I  
ANS9964I  
ANS9965S  
Migration stopped by user.  
Explanation: You requested that TSM stop the migrate operation.  
System Action: Migration stopped.  
User Response: Continue with normal operations.  
Selective Recall completed. Check failure list for possible errors.  
Explanation: The recall was completed.  
System Action: TSM recalled the files.  
User Response: Continue with normal operations.  
Selective Migration completed. Check failure list for possible errors.  
Explanation: The migration was completed.  
System Action: TSM migrated the files.  
User Response: Continue with normal operations.  
Please select a file system first.  
Explanation: You did not select any file system for the Migrate window.  
System Action: TSM ignores this request and continues.  
User Response: Select a file system, a directory, and all files you want to migrate,  
and then select the Migrate button to start the process.  
ANS9966S  
ANS9988S  
No file system has been selected.  
Explanation: You did not select a file system.  
System Action: TSM ignores the request and continues.  
User Response: Select at least one file system and retry the operation  
As part of the remove process, all migrated files in file-system will be recalled  
from TSM server. Do you want to continue with the remove process now?  
Explanation: When you remove space management from a file system, TSM  
recalls all migrated files.  
1330  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: TSM waits for your response before proceeding with the remove  
process.  
User Response: Select Yes to remove space management from the selected file  
system, or select Cancel to skip the remove.  
ANS9997W  
The selective migration, selective recall, or policy information window is  
displayed. Stop any operations, close the window, and then retry the operation.  
Explanation: When a node is contacting more than one server for space  
management services, the selective migration, selective recall, and policy  
information windows may not be displayed at the same time.  
System Action: TSM ignores the request.  
User Response: Close the selective migration, selective recall, or policy  
information window, and then retry the operation.  
ANS9998E  
The migration server changed after the selective migration or selective recall  
window was displayed. Close the window, and then retry the operation.  
Explanation: A migrate or recall operation will not be allowed to proceed if the  
user changed the migration server after the selective migration or selective recall  
window was displayed.  
System Action: No files will be migrated or recalled.  
User Response: Close the selective migration or selective recall window, and then  
retry the operation.  
Tivoli Storage Manager Messages  
1331  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1332  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV—Tivoli Data Protection  
Application Client Messages  
This section contains messages for the folowing:  
Tivoli Data Protection for Lotus Notes  
Tivoli Data Protection for Microsoft SQL  
Tivoli Data Protection for Oracle  
The messages are listed in numeric order.  
This section also contains Diagnosis, Modification, or Tuning Information. Some of  
these messages include information about the TSM error log that you can use when  
working with your service representative.  
Tivoli Storage Manager Messages  
1333  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1334  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Tivoli Data Protection for Lotus  
Notes (0900–0999)  
The messages in this section are for the Tivoli Data Protection for  
Lotus Notes.  
Notes:  
1. The term “database” refers to a Lotus Notes database.  
2. The term “notes” and “documents” are used interchangeably.  
For further information, refer to the following documents:  
For OS/2: Using the Lotus Notes Backup Agent  
For AIX: ADSMConnect Agent for Lotus Notes on AIX  
Installation and Users Guide  
For Windows NT: ADSMConnect Agent for Lotus Notes on  
Windows NT Installation and Users Guide  
ANS0900I  
ANS0901S  
dsmnotes completed.  
Explanation: The dsmnotes command completed successfully.  
System Action: The program completes.  
User Response: Not Applicable.  
Cannot allocate memory.  
Explanation: An attempt was made to allocate memory but failed.  
System Action: Processing stops.  
User Response: Check the LOG.DSM file for further details about the failure.  
Tivoli Storage Manager Messages  
1335  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS0903E  
I/O error opening file.  
Explanation: An I/O error occurred when an attempt was made to open one of the  
supporting files (for example: a trace file or log file). This message does not suggest  
an I/O error in a Notes database.  
System Action: Processing stops.  
User Response: Check all supporting files, including the log file, and trace file.  
Consider updating the environment variables in the NOTES.INI file to avoid using  
the problem file, or check access permission on the file.  
ANS0904E  
I/O error writing to a file.  
Explanation: An I/O error occurred when an attempt was made to write to a  
supporting file like a trace file or log file. This message does not suggest an I/O  
error in a Notes database.  
System Action: Processing stops.  
User Response: Check all supporting files, including the log file, and trace file.  
Consider updating the environment variables in the NOTES.INI file to avoid using  
the problem file. Also check your available disk space.  
ANS0905S  
ANS0907E  
ANS0908E  
Error getting current working directory.  
Explanation: An error occurred while trying to retrieve the current working  
directory.  
System Action: Processing stops.  
User Response: Check the LOG.DSM file for any further details on the specific  
error. There may be an error in your operating system since it cannot determine  
your current working directory.  
Error in getting file system information.  
Explanation: An error was encountered when an attempt was made to obtain the  
file system information for the drive on which the Notes database resides.  
System Action: Processing stops.  
User Response: Check the drive on which the Notes database you are processing  
resides. Be sure that the volume has a label and your disk is attached. Check the  
LOG.DSM file for details about the error.  
Error getting database volume label.  
Explanation: An error was encountered when an attempt was made to obtain the  
volume label of the drive on which the Notes database resides.  
System Action: Processing stops.  
User Response: Check the drive on which the Notes database you are processing  
resides. Be sure that the volume has a label and your disk is attached.  
1336  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0909E  
Error in parsing options.  
Explanation: A general parsing error occurred on a dsmnotes command. Either  
you entered too many path names, or a hyphen (-) or an equal (=) sign is missing in  
the option.  
System Action: Processing stops.  
User Response: Check the syntax of the command. Correct the syntax and reissue  
the command.  
ANS0910E  
ANS0912E  
Invalid option keyword.  
Explanation: An invalid option keyword was specified on a dsmnotes command.  
System Action: Processing stops.  
User Response: Identify and correct the invalid keyword. Then reissue the  
command.  
The specified password is too long.  
Explanation: The TSM password you entered is too long.  
System Action: Processing stops.  
User Response: If you are resetting a new TSM password, you need to choose a  
shorter password. If you are entering a current TSM password, check that the  
password is correct. If the password is correct but the problem still occurs, ask your  
TSM administrator to reset your password to a new value. If you do this, choose a  
shorter password.  
ANS0913E  
ANS0914E  
ANS0915E  
An invalid option value was specified.  
Explanation: An invalid value was specified for an option on a dsmnotes  
command.  
System Action: Processing stops.  
User Response: Identify and correct the invalid value. Then reissue the dsmnotes  
command.  
Required keywords are missing.  
Explanation: One or more required keywords are missing from the dsmnotes  
command.  
System Action: Processing stops.  
User Response: Identify and check the proper syntax and provide the missing  
keywords and values. Then reissue the dsmnotes command.  
An invalid date was entered.  
Explanation: An invalid date value was entered. Either the syntax of the value  
was not correct, or an actual value (for example, “45” for month) was invalid.  
System Action: Processing stops.  
User Response: Identify and correct the invalid date value. Refer to the user’s  
guide of the corresponding platform for the correct date syntax.  
Tivoli Storage Manager Messages  
1337  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0916E  
ANS0917E  
An invalid time was entered.  
Explanation: An invalid time value was entered. Either the syntax of the value  
was not correct, or an actual value (for example, “75” for hour) was invalid.  
System Action: Processing stops.  
User Response: Identify and correct the invalid date value. Refer to the user’s  
guide of the corresponding platform for the correct time syntax.  
Usage: dsmnotes <actions> <options> <db pathname>  
Explanation: No parameters were specified on the dsmnotes command. Some  
parameters are required such as action parameter and database name parameter.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct syntax of your command, including required parameters. Correct the syntax  
and reissue the command.  
ANS0918E  
dsmnotes action (1st parm) is unrecognized.  
Explanation: A syntax error was made on a dsmnotes command. The first  
parameter on the command is generally used to identify what kind of action is to be  
performed (for example, “INCR” for incremental backup), but this first parameter  
on the command was not recognized as a valid action.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct command syntax. Correct the syntax and reissue the command.  
ANS0919E  
ANS0920E  
ANS0921E  
Usage: dsmnotes incr <options> <db pathname>  
Explanation: A syntax error occurred on the incremental backup command.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct syntax. Correct the syntax and reissue the command.  
Usage: dsmnotes restore <options> <db pathname>  
Explanation: A syntax error occurred on the incremental backup command.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct syntax. Correct the syntax and reissue the command.  
Usage: dsmnotes restdel <options> <db pathname>  
Explanation: A syntax error occurred on the restore deletion stubs command.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct syntax. Correct the syntax and reissue the command.  
1338  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0923E  
Database path name is invalid.  
Explanation: The given path name does not resolve to a valid Notes database file  
name.  
System Action: Processing stops.  
User Response: Validate that the given path name is correct. If wildcard symbols  
are used, refer to the user’s guide of the corresponding platform for the correct  
usage of these symbols. Also check for defaulting to the Notes data directory to  
ensure that the path name is not defaulting incorrectly.  
ANS0924E  
ANS0925E  
ANS0926E  
Cannot restore to original database.  
Explanation: An attempt was made to rebuild a Notes database from backup  
copies of notes, but the original database file was specified as the target database.  
System Action: Processing stops.  
User Response: Choose an original name for the target database. The name cannot  
belong to an existing file.  
-days value cannot be negative (OS/2). The days value cannot be negative (AIX  
and Windows NT)  
Explanation: Only a positive number of days can be specified.  
System Action: Processing stops.  
User Response: Either specify a positive number of days or let the system default  
to restore all the deleted documents that it can identify.  
Cannot open database.  
Explanation: An attempt to open a Notes database was unsuccessful.  
System Action: Processing stops.  
User Response: Check the LOG.DSM file for more information about the error.  
Verify the path name of your database. If the path name is correct, then verify the  
database itself to ensure that it can be opened through the Notes workspace.  
ANS0928I  
ANS0929E  
Restore of Note(s) done.  
Explanation: Restoration of one or more notes was successful.  
System Action: The program completes successfully.  
User Response: None.  
User interrupted operation.  
Explanation: The user has interrupted the operation (for example, by pressing an  
interrupt key such as <Ctrl C>).  
System Action: Processing stops.  
User Response: None  
Tivoli Storage Manager Messages  
1339  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0930I  
ANS0931E  
Database rebuild done.  
Explanation: Database rebuild from backup copies of notes was successfully  
completed.  
System Action: The program completes successfully.  
User Response: None.  
Cannot log errors.  
Explanation: An attempt was made to initiate error logging, which includes either  
opening or creating a LOG.DSM file. The attempt failed.  
System Action: Processing stops.  
User Response: Check the LOG.DSM file to see why it cannot be opened or  
created.  
ANS0932I  
No matching data on server.  
Explanation: An attempt was made to query one or more backup copies of notes  
on the TSM server, but no copies existed or an attempt was made to merge the data  
notes (documents) from the TSM server into the original database, but no data notes  
existed.  
System Action: The program ends.  
User Response: If you believe that some matching data should exist on the server,  
check your database path name to ensure that you are using the correct database file  
name. If the -merge keyword is used, your database might only have nondata notes  
(documents).  
ANS0933E  
ANS0934E  
The days value is invalid.  
Explanation: The days value is either negative or greater than 65535.  
System Action: Processing stops.  
User Response: Use correct days value.  
TSM new passwords do not match.  
Explanation: An attempt was made to change the TSM password through the  
Lotus Notes workspace but the two new TSM passwords entered did not match.  
System Action: Processing stops.  
User Response: Retry the command with matching new TSM passwords.  
ANS0935E  
This Notes database file not on server.  
Explanation: Either the given database file was not backed up on the server, or  
the database file space was removed from the server.  
System Action: Processing stops.  
User Response: Check the name of the database to ensure that it is the correct  
database, and check the DSM.OPT file to ensure that you are accessing the correct  
TSM server. You can ask the TSM administrator to check the filespaces for your  
node. A database name is equivalent to a filespace.  
1340  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0936E  
This action is not allowed on a remote database.  
Explanation: The action you tried to perform is not allowed on a database that is  
not local.  
System Action: Processing stops.  
User Response: If the action is not allowed through the Notes workspace  
interface, but allowed through the TSM Notes application client command-line  
interface, then use the appropriate dsmnotes command. An alternative is to complete  
the action on the appropriate machine.  
ANS0937E  
Cannot enter new database name (OS/2). Must restore to original database  
(AIX and Windows NT).  
Explanation: You are not allowed to enter a new target database name for this  
restore operation.  
For OS/2, refer to the dsmnotes restore -FROMDATE option in the user’s guide  
documentation.  
System Action: Processing stops.  
User Response: If your interface is the Notes workspace, then replace the database  
name in the entry field with blanks. If your interface is a command, then do not  
specify a target (“-TO”) database.  
ANS0938E  
ANS0939I  
Database name required.  
Explanation: You are required to enter a database name.  
System Action: Processing stops.  
User Response: Enter the database name.  
No deletion stubs in database.  
Explanation: There are no deletion stubs in the given database.  
System Action: The program ends.  
User Response: If there are no deletion stubs in the database to initiate the restore,  
then you may need to rebuild the database by restoring the older version of the  
database file through the TSM client.  
ANS0940E  
Some options are mutually exclusive.  
Explanation: Some of the options specified are mutually exclusive. For example:  
For OS/2, the options “-MERGE=NO”, “-TO” and “-FROMDate” cannot all be  
specified simultaneously because a new target database may not be operable if  
some documents (such as view and form design documents) are excluded.  
Design documents are normally backed up with the initial incremental, and not  
subsequently modified. In this situation, allowing the FROMDate option would  
cause some design documents to be excluded when creating the new database.  
For AIX and Windows NT, the options “-MERGE” and “-TO” are mutually  
exclusive because a new target database cannot be specified for a merge.  
Tivoli Storage Manager Messages  
1341  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing stops.  
User Response: Correct the syntax of the command and then reissue the  
command.  
ANS0941E  
Invalid date/time range.  
Explanation: An invalid date or time range was given. For example, the “TO”  
time is earlier than the “FROM” time.  
System Action: Processing stops.  
User Response: Correct the date or time range and rerun the program. Be sure that  
all year, month, day, hour, and minute values are in the correct order and are valid  
values.  
ANS0942E  
No notes chosen.  
Explanation: An attempt was made to restore a note or notes, but no notes  
documents were chosen.  
System Action: Processing stops.  
User Response: On the lotus Notes Workspace, select the notes to be restored by  
placing a checkmark next to the notes.  
ANS0944E  
ANS0947E  
dsmnotes errors occurred.  
Explanation: Errors occurred on one or more databases.  
System Action: The program partially completes.  
User Response: Check the LOG.DSM file for further details about the failure.  
Error initializing Notes.  
Explanation: Error occurred while initializing the Lotus Notes runtime system.  
System Action: Processing stops.  
User Response: Check the Lotus Notes environment. Try to bring up your Notes  
workspace if you have not already done so. Also, check the NOTES.INI file to see  
if it has the correct setup for the Tivoli Data Protection application client. Refer to  
the user’s guide of the corresponding platform.  
ANS0948E  
ANS0950E  
Pathname is a directory.  
Explanation: An attempt was made to restore a single Database but the pathname  
specified was a directory.  
System Action: Processing stops.  
User Response: If you want to restore a single database, make sure your database  
name ends with a “.nsf” extension.  
Data on server has an invalid version.  
Explanation: Data structure for the application is not compatible with the data  
stored on the server.  
System Action: Processing stops.  
1342  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Check the user’s software version.  
ANS0951E  
Lotus Notes error: error_code occurred.  
Explanation: A Lotus Notes error has occurred but the Tivoli Data Protection  
application client was not able to translate the error code into a valid Lotus Notes  
error message.  
System Action: Processing stops.  
User Response: The supported Lotus Notes version is 4.50 for AIX and NT, or  
4.52 or above for OS/2. You probably have a downlevel Lotus Notes software  
installed on your system. Check with your Lotus Notes Administrator for assistance.  
ANS0952E  
ANS0953E  
TSM error: error_code occurred.  
Explanation: A TSM error has occurred but the Tivoli Data Protection application  
client was not able to translate the error code into a valid TSM error message.  
System Action: Processing stops.  
User Response: Check with your TSM Administrator for assistance.  
No license or license expired.  
Explanation: You do not have a valid Tivoli Data Protection application client  
license or your license has already expired.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform or call the  
IBM sales representatives for license information.  
ANS0955E  
Database IDs do not match.  
Explanation: An attempt was made to back up a database that has the same path  
and name as a database that is previously backed up to the TSM server. These two  
databases have the same name, but they have different database IDs. As a result,  
they were treated as two different databases.  
System Action: Processing stops.  
User Response: Rename the database to be backed up. If the database that is  
previously backed up in the TSM server is no longer needed, ask your TSM  
administrator to delete the database’s filespace on the server.  
ANS0956E  
The TSM password is needed.  
Explanation: A TSM password is required.  
System Action: Processing stops.  
User Response: If the TSM PASSWORDACCESS PROMPT option in the option  
file is used, you are required to enter the password by using the -adsmpw keyword.  
If the TSM PASSWORDACCESS GENERATE option is used, issue the dsmnotes  
change command with appropriate parameters to create a password file. Refer to the  
user’s guide of the corresponding platform for the correct syntax to use.  
Tivoli Storage Manager Messages  
1343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0957E  
ANS0958E  
An operation is already active.  
Explanation: An active restore operation is being processed.  
System Action: Processing stops.  
User Response: Wait for the active restore operation to complete before starting a  
second one.  
Usage: dsmnotes change -adsmpw=old -newadsmpw=new  
Explanation: The syntax of the dsmnotes change command is incorrect.  
System Action: Processing stops.  
User Response: Use correct syntax. Refer to the user’s guide of the corresponding  
platform for the correct syntax.  
ANS0959I  
ANS0960E  
TSM password changed.  
Explanation: The TSM password has been changed successfully.  
System Action: The program completes successfully.  
User Response: None.  
Cannot write over data in buffer.  
Explanation: An attempt was made to overwrite valid data in the buffer.  
System Action: Processing stops.  
User Response: Check the integrity of the database by opening it in the Lotus  
Notes workspace. If the database opens successfully, reissue the command. If the  
error is persistent, contact the IBM technical support.  
ANS0961E  
ANS0962E  
ANS0964E  
Database not allowed.  
Explanation: A database name is not allowed with this command.  
System Action: Processing stops.  
User Response: Remove the database name and reissue the command.  
Filespace not allowed.  
Explanation: A filespace name is not allowed with this command.  
System Action: Processing stops.  
User Response: Remove the filespace name and reissue the command.  
Invalid Notes Build Version.  
Explanation: A wrong version of Tivoli Data Protection application client is being  
used.  
System Action: Processing stops.  
User Response: Check the Tivoli Data Protection application client Readme file to  
verify if the installed Tivoli Data Protection application client supports the current  
version of Lotus Notes on your workstation. Uninstall the current version of Tivoli  
1344  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data Protection application client. Then reinstall and be sure to select the correct  
version of Tivoli Data Protection application client during the installation.  
ANS0970I  
ANS0971E  
Processing log file Logname.  
Explanation: The Tivoli Data Protection application client’s log file is being  
processed.  
System Action: Program continues.  
User Response: None.  
Too few parameters.  
Explanation: One or more parameters are required.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct number of parameters. Enter the correct number of parameters and reissue  
the command.  
ANS0972E  
Too many parameters.  
Explanation: Too many parameters were passed to the command.  
System Action: Processing stops.  
User Response: Refer to the user’s guide of the corresponding platform for the  
correct number of parameters. Enter the correct number of parameters and reissue  
the command.  
ANS0973E  
ANS0974E  
Invalid parameter: parameter.  
Explanation: An invalid parameter is entered.  
System Action: Processing stops.  
User Response: Correct the invalid parameter. Reissue the command.  
No log file is specified.  
Explanation: The Tivoli Data Protection application client’s log file is not entered.  
System Action: Processing stops.  
User Response: Enter a fully qualified Tivoli Data Protection application client log  
file, then reissue the command.  
ANS0975E  
No log database is specified.  
Explanation: The Lotus Notes log database is not entered.  
System Action: Processing stops.  
User Response: Enter the Lotus Notes log database (usually log.nsf). Refer to the  
user’s guide of the corresponding platform for further information.  
Tivoli Storage Manager Messages  
1345  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANS0976E  
ANS0977E  
Error opening the log database DBname.  
Explanation: The specified log database cannot be opened.  
System Action: Processing stops.  
User Response: Verify the path name of your log database. If the path name is  
correct, verify the log database itself to ensure that it can be opened through the  
Notes workspace.  
Error getting the mode of log database DBname.  
Explanation: The program cannot verify that the input log database is a valid  
database.  
System Action: Processing stops.  
User Response: Verify the path name of your log database. If the path name is  
correct, then verify the log database itself to ensure that it can be opened in the  
Notes workspace.  
ANS0978E  
ANS0979E  
ANS0980E  
ANS0981E  
DBname. is not a Lotus Notes database.  
Explanation: An invalid database has been specified.  
System Action: Processing stops.  
User Response: Verify the path name of your log database. If the path name is  
correct, verify the log database itself to ensure that it can be opened in the Notes  
workspace.  
Error closing log file Logname: system error code.  
Explanation: An I/O error occurred when an attempt was made to close the Tivoli  
Data Protection application client’s log file.  
System Action: Processing stops.  
User Response: Check the access permission on the Tivoli Data Protection  
application client’s log file.  
Error deleting log file Logname: system error code.  
Explanation: An I/O error occurred when an attempt was made to delete the  
Tivoli Data Protection application client’s log file.  
System Action: Processing stops.  
User Response: Check the access permission on the Tivoli Data Protection  
application client’s log file.  
Error getting log file start time.  
Explanation: The program is not able to interpret the first date/time stamp in the  
Tivoli Data Protection application client’s log file. The first date/time stamp format  
either does not match the date/time stamp format of your operating system, or it is  
corrupted.  
System Action: Processing stops.  
1346  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: For consistency reason, the date/time stamp format of the log file  
must match the date/time stamp format of your operating system. Check the locale  
of your operating system to ensure that you have matching date/time stamp formats.  
ANS0982E  
Error getting log file end time.  
Explanation: The program is not able to interpret the last date/time stamp in the  
TSMConnect Agent’s log file. The last date/time stamp format either does not match  
the date/time stamp format of your operating system, or it is corrupted.  
System Action: Processing stops.  
User Response: For consistency reason, the date/time stamp format of the log file  
must match the date/time stamp format of your operating system. Check the locale  
of your operating system to ensure that you have matching date/time stamp formats.  
ANS0983W  
Too large a record in log file.  
Explanation: One of the records in the Tivoli Data Protection application client is  
too large, or there is no carriage return character in the log file.  
System Action: Program continues.  
User Response: If the command is successful, check the log database to ensure  
that the correct record was added to the database. If the command fails, verify that  
the data in the Tivoli Data Protection application client’s log file is valid.  
ANS0984E  
Error opening the log file Logname: system error code.  
Explanation: An I/O error occurred when an attempt was made to open the Tivoli  
Data Protection application client’s log file.  
System Action: Processing stops.  
User Response: Verify the path name of the log file. Also Check the access  
permission on the log file.  
ANS0985E  
ANS0986I  
ANS0987E  
Error closing the database DBname: system error code.  
Explanation: An I/O error occurred when an attempt was made to close the log  
database.  
System Action: Processing stops.  
User Response: Check the access permission on the log database.  
Log file Logname successfully written to DBname.  
Explanation: The Tivoli Data Protection application client’s log file has been  
successfully written to the log database.  
System Action: The program completes successfully.  
User Response: None.  
Log file Logname NOT written to DBname.  
Explanation: The Tivoli Data Protection application client’s log file was not  
written to the log database due to error.  
Tivoli Storage Manager Messages  
1347  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing stops.  
User Response: Check the error messages that preceded this message.  
ANS0988I  
ANS0989E  
Log file Logname deleted.  
Explanation: The Tivoli Data Protection application client’s log file was deleted  
because the “-d” option was used.  
System Action: The program completes successfully.  
User Response: None.  
Log file Logname was NOT deleted, due to error.  
Explanation: The user has used the option “-d” but the Tivoli Data Protection  
application client’s log file was NOT deleted due to error.  
System Action: Processing stops.  
User Response: Check the error messages that preceded this message.  
1348  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
Tivoli Data Protection for  
Microsoft SQL (ACO0301-5203)  
ACO0301E  
Invalid option found while processing options file.  
Explanation: A request was made to the ADSM API. While the API was  
processing the request, there was an invalid option found in the options file.  
System Action: The current request is ended.  
User Response: The option in error is written to the DSIERROR.LOG. View this  
file and modify this option appropriately.  
ACO0601E  
ACO0602E  
Unable to read from tips file.  
Explanation: An attempt was made to read from the “Tips of the Day” file.  
System Action: No tip is displayed.  
User Response: Be sure that the tips file is installed and had not been corrupted.  
Error detecting protocols.  
Explanation: An attempt was made to detect the protocols that are installed on  
this machine. The attempt to get this information failed.  
System Action: The list box of protocols is displayed with this message.  
User Response: Determine if the protocols on your system are functioning. If they  
are, try to run the command again. If not, fix the protocols in error, and run the  
command again.  
ACO0603E  
Could not load the resource dll -- %1 Either reinstall or replace the copy of the  
missing DLL file.  
Explanation: An attempt was made to load the DLL listed in the message.  
System Action: The agent is not loaded.  
User Response: Either reinstall the agent or replace the copy of the DLL listed in  
the message with the current level of the DLL.  
Tivoli Storage Manager Messages  
1349  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACO0604E  
Could not determine the ADSM database agent source path.  
Explanation: An attempt was made to read the registry to determine where the  
agent was installed.  
System Action: Processing continues getting the information that it needs from the  
current directory.  
User Response: There are two choices: either cancel the request if the correct files  
are not in the current directory, or allow the request to complete and take action as  
to whether the correct results were obtained. This error may indicate that you are  
not running with the required permissions. Make sure you are running with local  
administrator permission. This may also indicate that the agent was not installed  
properly and may require a reinstall.  
ACO0609E  
ACO0610E  
ACO0611E  
A TCP/IP address is required.  
Explanation: The chosen protocol was TCP/IP. However, there was not a TCP/IP  
address entered.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor to enter the  
TCP/IP address. Or, you may choose to cancel from the editor.  
A TCP/IP port number is required.  
Explanation: The chosen protocol was TCP/IP. However, there was not a TCP/IP  
port value entered.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor to enter the  
TCP/IP port value. Or, you may choose to cancel from the editor.  
TCP/IP port value must be between 1000 and 32767.  
Explanation: The chosen protocol was TCP/IP. The value entered for the TCP/IP  
port is not valid.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor to enter the  
TCP/IP port value between 1000 and 32767. Or, you may choose to cancel from the  
editor.  
ACO0612E  
Error obtaining message from resource dll.  
Explanation: An attempt was made to get a message from the message DLL. This  
attempt failed.  
System Action: This message is displayed in the protocol box.  
User Response: The agent should be reinstalled. This will include the correct  
version of the message DLL.  
1350  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO0616E  
ACO0617E  
ACO0618E  
ACO0619E  
ACO0620E  
ACO1604E  
A Named pipe name is required.  
Explanation: The chosen protocol was Named Pipe. However, there was no value  
entered for the Named Pipe Name.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the Named Pipe Name. Or, you may choose to cancel from the editor.  
A NetBIOS name is required.  
Explanation: The chosen protocol was NetBIOS. However, there was no value  
entered for the NetBIOS Name.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the NetBIOS Name. Or, you may choose to cancel from the editor.  
A NetBIOS servername is required  
Explanation: The chosen protocol was NetBIOS. However, there was no value  
entered for the NetBIOS Server Name.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the NetBIOS Server Name. Or, you may choose to cancel from the editor.  
An IPX socket value is required.  
Explanation: The chosen protocol was IPX/SPX. However, there was no value  
entered for the IPX socket.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the IPX socket. Or, you may choose to cancel from the editor.  
An IPX server address is required.  
Explanation: The chosen protocol was IPX/SPX. However, there was no value  
entered for the IPX Server Address.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the IPX Server Address. Or, you may choose to cancel from the editor.  
Unable to obtain message number %1!u! from %2  
Explanation: An error occurred while obtaining a message from the message  
DLL.  
System Action: Processing continues.  
User Response: Verify that the correct Agent message DLL is installed. If the  
error continues contact IBM ADSM support.  
Tivoli Storage Manager Messages  
1351  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2218E  
ACO2219E  
ACO2504E  
Unknown error. RC: %1!u!  
Explanation: An attempt was made to get the text of a system error.  
System Action: Instead of getting the system error text, this message is used. The  
Agent code continues.  
User Response: Determine if the current level of the system DLL is loaded.  
Unable to find system message  
Explanation: An attempt was made to get the text of a system error.  
System Action: Instead of getting the system error text, the current message is  
displayed.  
User Response: Determine if the current level of the system DLL is loaded.  
The name specified in the Adsm server identifier field cannot include periods  
(’.’). Please re-enter.  
Explanation: The name specified in the ADSM server identifier field contains one  
or more periods.  
System Action: The agent prompts for another server identifier.  
User Response: The user should enter a name without a period.  
ACO2518E  
ACO2519E  
Invalid command line parameter: %1  
Explanation: An invalid parameter has been entered on the command line.  
System Action: Processing ends.  
User Response: Re-enter the command and be sure to enter a valid command line.  
Out of Heap Space.  
Explanation: An attempt was made to allocate a buffer. However, there is no more  
heap space for the buffer.  
System Action: Processing ends.  
User Response: Try stopping other processes, and retry the operation.  
ACO2520E  
ACO2521E  
Incomplete command line parameter: %1  
Explanation: The command you entered was incomplete.  
System Action: Processing ends.  
User Response: View the line displayed in the message. Determine the error and  
re-issue the command.  
Parameter ’%1’ conflicts with previous parameters.  
Explanation: A parameter has been entered on the command line that conflicts  
with a previous parameter that was entered.  
System Action: Processing ends.  
1352  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: From the message displayed, the conflicting parameter is  
identified. View the command line to discover the conflict and re-enter the  
command correctly.  
ACO2522E  
/ADSMNODE option is not valid when PASSWORDACCESS GENERATE is  
specified in the options file, %1.  
Explanation: The ADSMNODE and PASSWORDACCESS GENERATE may not  
be specified at the same time.  
System Action: Processing ends.  
User Response: Re-enter the command with either ADSMNODE or  
PASSWORDACCESS GENERATE.  
ACO2526W  
ACO2527E  
The amount of data exceeds the available buffer space for this query.  
Explanation: There was not enough buffer space to receive all of the information  
regarding the SQL databases.  
System Action: Processing continues.  
User Response: Re-issue the command to see if the complete list can now be  
obtained. If the problem persists, contact IBM ADSM support.  
No ADSM servers (options files) were found.  
Explanation: An attempt was made to locate all of the ADSM servers. This  
attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there are options files defined for your ADSM  
servers.  
ACO2534E  
ACO2536E  
ACO2539E  
Missing TCP/IP address.  
Explanation: There is no TCP/IP address defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, a TCP/IP address needs  
to be defined.  
Missing TCP/IP port.  
Explanation: There is no TCP/IP port defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, a TCP/IP port value  
needs to be defined.  
Missing IPX/SPX address.  
Explanation: There is no IPX/SPX address defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, an IPX/SPX address  
needs to be defined.  
Tivoli Storage Manager Messages  
1353  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2541E  
ACO2544E  
ACO2546E  
ACO2550E  
ACO2552E  
Missing IPX/SPX socket.  
Explanation: There is no IPX/SPX socket value defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, an IPX/SPX socket value  
needs to be defined.  
Missing NetBIOS name.  
Explanation: There is no NetBIOS name defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, a NetBIOS name will  
need to be defined.  
Missing NetBIOS server name.  
Explanation: There is no NetBIOS server name defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, a NetBIOS server name  
will need to be defined.  
Missing Named Pipe name.  
Explanation: There is no Named Pipe Name defined for the ADSM server.  
System Action: Processing continues.  
User Response: Before connecting to this ADSM server, a Named Pipe Name will  
need to be defined.  
Could not open %1.opt.  
Explanation: An attempt was made to open the options file defined in the  
message.  
System Action: Processing ends.  
User Response: Determine if the options file exists. If it does, try issuing the  
command again. If it does not, create the file and try issuing the command again.  
ACO2553E  
ACO2557E  
File error reading from %1.opt.  
Explanation: An attempt was made to read from the options file defined in the  
message.  
System Action: Processing ends.  
User Response: Determine if there is an error with the options file. Try running  
the command again.  
License file (%1) could not be opened. Reason: %2  
Explanation: At attempt was made to read from the license file. This attempt  
failed.  
System Action: Processing ends.  
1354  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Reinstall the product. This will ensure that the correct license file  
is installed.  
ACO2558E  
Read failure on license file (%1).  
Explanation: An attempt was made to read from the license file. This attempt  
failed.  
System Action: Processing ends.  
User Response: Reinstall the product. This will ensure that the correct license file  
is installed.  
ACO2559E  
ACO2560E  
ACO2561E  
ACO2562E  
Write failure on license file (%1).  
Explanation: An attempt was made to write to the license file. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the workstation to write the  
file. If there is, try running the command again.  
Data in the license file (%1) is not in a valid format.  
Explanation: An attempt was made to read information from the license file. This  
attempt failed.  
System Action: Processing ends.  
User Response: Reinstall the product.  
The checksum in the license file (%1) does not match the license string text.  
Explanation: An attempt was made to read information from the license file. The  
checksum was not valid so it appears the license file is not at the correct level.  
System Action: Processing ends.  
User Response: Reinstall the product.  
This is an expired ’Try and Buy’.  
Explanation: While reading the license file, it was determined that the Try and  
Buy license has expired.  
System Action: Processing ends.  
User Response: This product is no longer valid for use. A valid license must be  
obtained before running the product.  
ACO2563E  
Unrecognized return code from the ADSM license manager.  
Explanation: An attempt was made to read information from the license file. This  
attempt failed.  
System Action: Processing ends.  
User Response: Reinstall the product.  
Tivoli Storage Manager Messages  
1355  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2564E  
Unable to open log file: %1.  
Explanation: An attempt was made to open the log file specified in the message.  
This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
ACO2565E  
ACO2570E  
Unable to open trace file: %1.  
Explanation: An attempt was made to open the trace file. This attempt failed.  
System Action: Processing ends.  
User Response: Re-issue the command. Either specify a different trace file or do  
not specify a trace file.  
Your ADSM password has expired.  
Explanation: An attempt was made to connect to the ADSM server. However, the  
ADSM password has expired.  
System Action: Processing ends.  
User Response: Reset the ADSM password for the node.  
ACO2573E  
ACO2574E  
ACO2575E  
ACO2576E  
A server name is required.  
Explanation: A value was not entered for the server name.  
System Action: Processing has focus on the server name.  
User Response: Enter a server name.  
A computer name is required.  
Explanation: A value was not entered for the computer name.  
System Action: Processing has focus on the computer name.  
User Response: Enter a computer name.  
A login ID is required.  
Explanation: A value was not entered for the login ID.  
System Action: Processing has focus on the login ID.  
User Response: Enter a login ID.  
TCP/IP is not active on this computer.  
Explanation: An attempt was made to use the TCP/IP protocol. This attempt  
failed.  
System Action: Processing ends.  
User Response: If the protocol wanted is truly TCP/IP, then be sure that TCP/IP is  
installed and configured correctly. When this is done, re-issue the command.  
1356  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2577E  
ACO2578E  
ACO2579E  
ACO2580E  
ACO2581E  
ACO2582E  
An IPX socket value is required.  
Explanation: The chosen protocol was IPX/SPX. However, there was no value  
entered for the IPX socket.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the IPX socket.  
An IPX server address is required.  
Explanation: The chosen protocol was IPX/SPX. However, there was no value  
entered for the IPX Server Address.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the IPX Server Address.  
A TCP/IP port number is required.  
Explanation: The chosen protocol was TCP/IP. However, there was not a TCP/IP  
port value entered.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor to enter the  
TCP/IP port value. Or, you can choose to cancel from the editor.  
A TCP/IP address is required.  
Explanation: The chosen protocol was TCP/IP. However, there was not a TCP/IP  
address entered.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor to enter the  
TCP/IP address. Or, you may choose to cancel from the editor.  
A NetBIOS name is required.  
Explanation: The chosen protocol was NetBIOS. However, there was no value  
entered for the NetBIOS Name.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the NetBIOS Name.  
A NetBIOS servername is required.  
Explanation: The chosen protocol was NetBIOS. However, there was no value  
entered for the NetBIOS Server Name.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the NetBIOS Server Name.  
Tivoli Storage Manager Messages  
1357  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2583E  
ACO2584E  
A Named pipe name is required.  
Explanation: The chosen protocol was Named Pipe. However, there was no value  
entered for the Named Pipe Name.  
System Action: The Options File Editor will be redisplayed.  
User Response: Press the Settings button on the Options File Editor and enter a  
value for the Named Pipe Name.  
Failed to delete the specified options file.  
Explanation: An attempt was made to delete the options file. This attempt failed.  
System Action: Processing ends.  
User Response: It is possible that the file is a read-only file, or exists on a volume  
that you do not have authority to delete from. Determine the problem and re-enter  
the request.  
ACO2585E  
ACO2589E  
The machine ran out of memory while processing the database tree.  
Explanation: While preparing the tree of the databases to display, the machine ran  
out of memory.  
System Action: Processing continues.  
User Response: Free up some of the system memory and rerun the application.  
The specified database objects are not available on the selected ADSM server  
(%1).  
Explanation: An attempt was made to list the database objects that exist on an  
ADSM server. However, there are no objects on the ADSM server selected for this  
database.  
System Action: Processing ends.  
User Response: Choose a server that has the database object, or backup the  
database object to this specific server.  
ACO2590W  
The amount of data exceeds the available buffer space for this query. Click OK  
to see a partial list of objects.  
Explanation: There was not enough buffer space to hold all of the information  
from the ADSM Server. However, a partial list was obtained.  
System Action: Processing will continue showing the partial list.  
User Response: Determine if this is okay. If not, free up some buffer space and  
reissue the request.  
ACO2592E  
ADSM server name required  
Explanation: A value needs to be entered for the ADSM Server Name.  
System Action: Processing has focus on the ADSM Server Identifier.  
User Response: Enter an ADSM Server name.  
1358  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2593E  
ACO2594E  
An ADSM server named %1 is already defined. Enter a new name to continue.  
Explanation: A value was entered for the ADSM Server name. However, this  
server name already exists.  
System Action: Processing has focus on the server name.  
User Response: Enter a unique ADSM Server name.  
Could not find Internet Explorer  
Explanation: An attempt was made to read the registry to determine where  
Microsoft’s Internet Explorer was installed. This attempt failed.  
System Action: Processing ends.  
User Response: Make sure that the registry is set up correctly for Internet  
Explorer.  
ACO2595E  
ACO2596E  
ACO2597I  
Could not find the ADSM HTML books  
Explanation: An attempt was made to read the registry to determine where the  
agent was installed. This attempt failed.  
System Action: Processing ends.  
User Response: It may be necessary to reinstall the agent code. This will ensure  
that the registry entries are set up correctly.  
Failed to start Web browser  
Explanation: An attempt was made to start the web browser to view the ADSM  
HTML book. This attempt failed.  
System Action: Processing ends.  
User Response: Start your web browser manually and point it to bookfrm.htm in  
the agent htm directory.  
Could not find the default browser defined. An attempt will be made to use  
Microsoft’s Internet Explorer.  
Explanation: An attempt was made to read the registry to determine the default  
browser. However, there was not one defined. It will be determined where Microsoft  
Internet Explorer is installed.  
System Action: Processing continues.  
User Response: It is possible that a default browser is not defined for the system.  
This is okay. An attempt will be made to use Microsoft’s Internet Explorer.  
ACO2598E  
Failed to create RAS process.  
Explanation: An attempt was made to start the Dial-Up Networkingapplication.  
This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the RASPHONE.EXE file is installed in the  
appropriate directory.  
Tivoli Storage Manager Messages  
1359  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2599E  
ACO2600E  
ACO2601E  
ACO2602E  
Failed to create a system diagnostics process.  
Explanation: An attempt was made to view the System Diagnostics. This attempt  
failed.  
System Action: Processing ends.  
User Response: Be sure that the WINMSD.EXE executable exists in the  
appropriate directory.  
Could not determine the Backup-archive client path.  
Explanation: An attempt was made to determine the path of where the ADSM  
Backup-Archive client is installed. This attempt failed.  
System Action: Processing ends.  
User Response: It is possible that the ADSM Backup-Archive client was not  
installed properly. Reinstall the client so that the proper registry entries are written.  
Could not determine the Administrative client path.  
Explanation: An attempt was made to determine the path where the ADSM  
Administrative client is installed. This attempt failed.  
System Action: Processing ends.  
User Response: It is possible that the ADSM Administrative client was not  
installed properly. Reinstall the client so that the proper registry entries are written.  
Could not determine the Server path.  
Explanation: An attempt was made to locate where the ADSM Server was  
installed. This attempt failed.  
System Action: Processing ends.  
User Response: It is possible that the registry entries are not set up correctly. You  
may want to reinstall the ADSM server code to ensure that the ADSM Server  
registry entries are set up appropriately.  
ACO2603E  
Failed to create Backup-archive client process.  
Explanation: An attempt was made to start the ADSM Backup-Archive client.  
This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the DSM.EXE executable exists in the appropriate  
directory. If it is not, you may need to reinstall the Backup-Archive client to ensure  
the registry entries are set up appropriately.  
ACO2604E  
Failed to create the Administrative client process.  
Explanation: An attempt was made to start the Client Administrative GUI. This  
attempt failed.  
System Action: Processing ends.  
1360  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Be sure that the DSMADM.EXE file is installed to the  
appropriate directory. If it is not, you may need to reinstall the ADSM Client  
Administrative GUI to ensure the registry entries are set up correctly.  
ACO2605E  
ACO2608E  
Failed to start the event viewer.  
Explanation: An attempt was made to start the event viewer. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the EVENTVWR.EXE file is installed in the  
appropriate directory.  
Failed to create ADSM Server process.  
Explanation: An attempt was made to start the ADSM Server Console. This  
attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the DSMSERV.EXE file is located in the correct  
directory.  
ACO2610E  
Could not determine the Server Utilities path.  
Explanation: An attempt was made to read the registry to get the location of the  
server utilities. This attempt failed.  
System Action: Processing ends.  
User Response: Determine whether or not the Server Utilities are installed. If not,  
you may want to reinstall the Utilities so that the registry entries are set up  
appropriately.  
ACO2611E  
Failed to create Server Utilities process.  
Explanation: An attempt was made to start the server utilities executable. This  
attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the ADSM.EXE file is installed to the appropriate  
directory. If it is not, you may want to reinstall the ADSM Server Utilities to ensure  
the registry entries are set up correctly.  
ACO2615E  
ACO2616E  
No ADSM Servers are selected.  
Explanation: A backup of a database was selected, however there was no ADSM  
server chosen to backup to.  
System Action: Processing ends.  
User Response: Re-issue the command specifying an ADSM server.  
No ADSM Agents are selected.  
Explanation: An attempt was made to either restore a database or delete a  
database backup on the ADSM server. This attempt failed.  
System Action: Processing ends.  
Tivoli Storage Manager Messages  
1361  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Select an ADSM agent and re-issue the command.  
ACO2617E  
ACO2618E  
An ADSM password is required.  
Explanation: In order to issue this request, an ADSM password is required.  
System Action: Processing ends.  
User Response: Re-issue the command specifying an ADSM password.  
The passwords you typed do not match. Type the new password in both text  
boxes.  
Explanation: A check was done between the “New password” and the “Confirm  
new password” boxes. They were not the same.  
System Action: The “Change ADSM Password” box is redisplayed.  
User Response: Re-enter the new password or cancel from the task.  
ACO2619E  
An ADSM servername must be selected.  
Explanation: An attempt was made to change the ADSM password for a node.  
This attempt failed.  
System Action: The “Change ADSM Password” box is redisplayed.  
User Response: Re-enter the change request and make sure to fill in the “ADSM  
Server” field. Or, you can cancel the task.  
ACO2621E  
ACO2622E  
Unable to activate help.  
Explanation: An attempt was made to bring up the help panel on how to use help.  
This attempt failed.  
System Action: Processing continues.  
User Response: Retry the operation. If it still fails, try reinstalling the Agent.  
Please enter no more than %1!u! characters.  
Explanation: The value you entered was more than the number of allowable  
characters. The maximum number of characters allowed for this field is shown in  
the message.  
System Action: Processing has focus on the field that needs to be updated.  
User Response: Enter a new value keeping in mind the maximum number of  
characters that are allowed.  
ACO2623E  
The default dsm entry is a requirement of the ADSM API. All parameters  
except the name can be changed.  
Explanation: An attempt was made to rename the default dsm entry. However, the  
dsm entry is a requirement of the ADSM API and must exist.  
System Action: Processing has focus on the ADSM Server name.  
User Response: Any other parameter may be changed except for the dsm entry.  
1362  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2624E  
ACO2625E  
ACO2626E  
ADSM client node required.  
Explanation: A request was made to update or create a new ADSM Server options  
file. However, there was no ADSM node defined. This is required.  
System Action: Processing has focus on the ADSM client node name.  
User Response: Enter an ADSM Client node name.  
Internal error detected. Retry the operation.  
Explanation: An internal processing error has been detected.  
System Action: Unpredictable.  
User Response: Retry the operation. If the problem still occurs, report how you  
obtained this error to IBM ADSM support.  
Unresolved command line error, rc = %1!d!. Report how you obtained this  
error.  
Explanation: An internal processing error has been detected.  
System Action: Unpredictable.  
User Response: Retry the operation. If the problem still occurs, report how you  
obtained this error to IBM ADSM support.  
ACO2627E  
Unable to write to the system registry: %1  
Explanation: An attempt to write a system registry entry failed. The reason for the  
failure may or may not be provided.  
System Action: Processing ends.  
User Response: If the reason for the failure is provided, take the appropriate  
action(s). This may indicate that you are not running with the required permissions.  
Make sure you are running with local administrator permission. If there is still a  
problem, contact IBM ADSM support.  
ACO2629E  
Error opening log file %1.  
Explanation: An attempt was made to open the log file specified in the message.  
This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
ACO2630E  
Error reading log file %1.  
Explanation: An attempt was made to read the log file specified in the message.  
This attempt failed.  
System Action: Processing ends.  
User Response: Determine if there is an error with the log file. Try running the  
command again.  
Tivoli Storage Manager Messages  
1363  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO2631E  
ACO2632E  
ACO2633E  
ACO2634E  
ACO2635E  
ACO2636E  
Error writing log file %1.  
Explanation: An attempt was made to write to the log file specified in the  
message. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
Error flushing log file %1.  
Explanation: An attempt was made to write the log file from buffers to disk. This  
attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
Error closing log file %1.  
Explanation: An attempt was made to close the log file specified in the message.  
This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
Error deleting log file %1.  
Explanation: An attempt was made to delete the log file specified in the message.  
This attempt failed.  
System Action: Processing ends.  
User Response: It is possible that the file is a read-only file or exists on a volume  
that you are do not have authority to delete from. Determine the problem and  
re-enter the request.  
Error opening temporary log file while pruning %1.  
Explanation: An attempt was made to open the temporary log file specified in the  
message. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
Error writing temporary log file while pruning %1.  
Explanation: An attempt was made to write to the temporary log file specified in  
the message. This attempt failed.  
1364  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
ACO2637E  
ACO2638E  
ACO2639E  
Error flushing temporary log file while pruning %1.  
Explanation: An attempt was made to flush the temporary log file specified in the  
message. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
Error closing temporary log file while pruning %1.  
Explanation: An attempt was made to close the temporary log file specified in the  
message. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that there is enough space on the disk where the log file  
is being written. Make sure the user has the correct permissions to write to the  
directory. Re-issue the command.  
Error renaming temporary log file while pruning %1.  
Explanation: An attempt was made to rename the temporary log file specified in  
the message. This attempt failed.  
System Action: Processing ends.  
User Response: Determine if there is an error with the temporary log file. Try  
running the command again.  
ACO2640I  
ACO2641I  
ACO3001E  
Log file %1 successfully pruned.  
Explanation: The log file has been successfully pruned as requested.  
System Action: None.  
User Response: None.  
Log file %1 already meets the log prune specifications: no action taken  
Explanation: The log file is unchanged by the prune process.  
System Action: None.  
User Response: None.  
No SQL servers are available.  
Explanation: A check was done to determine if a SQL Server was installed on this  
machine. A SQL Server does not exist on this workstation.  
System Action: Processing ends.  
User Response: Install the SQL Server and re-issue the command.  
Tivoli Storage Manager Messages  
1365  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3006E  
ACO3009E  
The specified object(s) were not found.  
Explanation: A request was made to get a list of SQL databases. This request  
returned no databases.  
System Action: Processing ends.  
User Response: Determine if there is a problem with SQL. Re-enter the command.  
ERROR - /NOTRUNCATE cannot be used with a full database backup.  
Explanation: A request was made to do a full backup of a database using the  
/NOTRUNCATE option. This is not valid.  
System Action: Processing ends.  
User Response: Re-enter the command. Do not specify the /NOTRUNCATE  
option.  
ACO3010E  
ERROR - /TRUNCAFTER cannot be used with an incremental backup.  
Explanation: A request was made to do an incremental backup of a database using  
the /TRUNCAFTER option.  
System Action: Processing ends.  
User Response: Re-enter the command. Do not specify the /TRUNCAFTER  
option.  
ACO3019E  
ACO3024E  
ACO3026E  
ACO3027E  
An error was encountered.  
Explanation: While processing the request, there was an error encountered.  
System Action: Processing ends.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
Unable to obtain ADSM error message.  
Explanation: An ADSM error has occurred.  
System Action: Processing ends.  
User Response: Retry the operation. If the same error persists, call IBM ADSM  
support and report how the error occurred.  
Error:  
Explanation: An error has occurred processing the request.  
System Action: Processing ends.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
Error: ADSM server errors encountered.  
Explanation: While processing the request, there were ADSM server errors.  
System Action: Processing ends.  
1366  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
ACO3028E  
ACO3030E  
ACO3036E  
ACO3055E  
Error: SQL server errors encountered.  
Explanation: While processing the request, there were SQL server errors.  
System Action: Processing ends.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
Truncation failure:  
Explanation: An error occurred trying to truncate the transaction log.  
System Action: Processing ends.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
Error: %1  
Explanation: An error has occurred reading the options file.  
System Action: Processing ends.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
Error: An invalid ADSM database information record was detected and  
ignored.  
Explanation: This is an internal error with the format of an ADSM database  
information record.  
System Action: The invalid database information record is ignored.  
User Response: Retry the operation. If this error persists, contact IBM ADSM  
support.  
ACO3057E  
ACO3505E  
ERROR - The /IFOLDer option is required for this operation.  
Explanation: This option needs te be entered for the /ADSMAUTODELete  
command.  
System Action: Processing ends.  
User Response: Re-enter the command specifying the /IFOLDer option.  
Failed write to SQL server. Check SQL server error log.  
Explanation: An attempt was made to restore a SQL database. This attempt failed  
to write to the SQL server.  
System Action: Processing ends.  
User Response: Refer to the SQL server log for a better understanding of the  
problem.  
Tivoli Storage Manager Messages  
1367  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3801E  
ACO3802E  
A SQL server name or * must be entered.  
Explanation: A request was made that requires a SQL server name or an asterisk  
(*) to be specified.  
System Action: Processing ends.  
User Response: Re-enter the request specifying a valid SQL server name.  
A database name or * must be entered.  
Explanation: A request was made that requires a database name or an asterisk ( *  
) to be specified.  
System Action: Processing ends.  
User Response: Re-enter the request specifying a valid database name.  
ACO3803E  
ACO3809E  
Unable to obtain ADSM error message. Please report how you got here.  
Explanation: There was an error with the task for ADSM to backup the database.  
System Action: Processing ends.  
User Response: Please report how you obtained this error to ADSM service.  
Truncation failed  
Explanation: An attempt was made to truncate the transaction log. This attempt  
failed.  
System Action: Processing ends.  
User Response: Check the SQL Server error log for more details. Correct the  
problem and retry.  
ACO3810E  
An error was encountered  
Explanation: An attempt was made to issue a backup request. An unknown error  
was encountered while trying to do the backup.  
System Action: Processing ends.  
User Response: Check the SQL Server error log for more details. Correct the  
problem and retry.  
ACO3812I  
ACO3813E  
Please enter a password for the ADSM node.  
Explanation: This is a prompt message.  
System Action: Processing waits for a password to be entered.  
User Response: Enter a password for the ADSM node.  
Please enter a log file name.  
Explanation: An attempt was made to update the log file for the agent.  
System Action: The Activity Loggingtab on the SQL Agent Settingspanel is  
redisplayed.  
User Response: Enter a log file name.  
1368  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3815E  
ACO3816E  
Failed to start the SQL Enterprise Manager.  
Explanation: An attempt was made to start the SQL Enterprise Manager. This  
attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the SQLEW.EXE file is installed in the appropriate  
directory.  
Failed to create an Editor process.  
Explanation: An attempt was made to open an edit session using the notepad  
utility of the dsm.opt file. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the notepad utility is installed in the appropriate  
directory. Also, be sure that the DSM.OPT file exists in the ADSM directory of  
either the ADSM Backup Client or the ADSM Administrative client, whichever you  
are trying to edit.  
ACO3817E  
ACO3818E  
ACO3823E  
Could not set new image for SQL server tree item.  
Explanation: The state icon may not reflect the current state of the SQL Server.  
System Action: Processing continues.  
User Response: Retry the operation.  
Could not set new label for SQL server tree item.  
Explanation: The label for the SQL Server tree item may not be up to date.  
System Action: Processing continues.  
User Response: Retry the operation.  
The ADSM API DLLs are at a lower version than the application. Install the  
current ADSM API DLLs to ensure correct operation.  
Explanation: The current ADSM API DLL that is running is a lower version than  
what the SQL Agent needs. The SQL Agent is expecting the ADSM API DLL to be  
at least Version 3.  
System Action: The SQL Agent command is terminated.  
User Response: Install the Version 3 ADSM API.  
ACO3825E  
The ADSM API DLLs are at a lower release than the application. Install the  
current ADSM API DLLs to ensure correct operation.  
Explanation: The current ADSM API DLL that is running is a lower release than  
what the SQL Agent needs. The SQL Agent is expecting the ADSM API DLL to be  
at least Release 1.  
System Action: The SQL Agent command is terminated.  
User Response: Install the Version 3, Release 1 ADSM API.  
Tivoli Storage Manager Messages  
1369  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3830I  
ACO3831E  
No SQL Servers are available.  
Explanation: There are no SQL servers available to display in the tree.  
System Action: Processing ends.  
User Response: Check to make sure that SQL is installed properly.  
Could not set new label for SQL Agent tree item.  
Explanation: The label for the SQL Agent tree item may not contain the most  
current label.  
System Action: Processing continues.  
User Response: Retry the operation.  
ACO3832E  
ACO3833E  
Could not set new image for SQL Agent tree item.  
Explanation: The image for the SQL Agent tree item may not contain the most  
current image.  
System Action: Processing continues.  
User Response: Retry the operation.  
The SQL Server path cannot be found.  
Explanation: An attempt was made to read the registry to determine where the  
SQL Server was installed. This attempt failed.  
System Action: Processing ends.  
User Response: Make sure you are running with the required permissions (local  
administrator). If it still fails, try reinstalling the product.  
ACO3834E  
ACO3835E  
Could not initialize OLE.  
Explanation: An attempt was made to initialize the OLE DLLs. This attempt  
failed.  
System Action: Processing ends.  
User Response: Be sure that the correct version of the OLE system DLL’s are  
installed.  
The ADSMConnect Agent is not properly installed. The ADSMConnect Agent  
for Microsoft SQL Server registry key could not be located. Please reinstall the  
agent.  
Explanation: An attempt was made to read the registry to determine where the  
ADSMConnect Agent for Microsoft SQL Server was installed. This attempt failed.  
System Action: Processing ends.  
User Response: Reinstall the SQL Agent to ensure that the registry is set up  
properly.  
1370  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3836E  
The ADSMConnect Agent for Microsoft SQL Server is not properly installed.  
%1 is a required file and could not be located. Please reinstall the agent.  
Explanation: An attempt was made to start the SQL Agent. This attempt failed  
because one of the required files is missing. The missing part is identified in the  
message.  
System Action: Processing ends.  
User Response: Reinstall the SQL Agent to ensure that the registry is set up  
properly.  
ACO3856E  
A password must be entered.  
Explanation: There was a prompt to enter a password for the ADSM node.  
However, the password was not given.  
System Action: Processing continues on the panel to enter the password for the  
ADSM node.  
User Response: Reenter the password for the ADSM node.  
ACO3857E  
ACO3858E  
A confirm password must be entered.  
Explanation: On the password prompt panel, you must enter a confirm password.  
System Action: Processing is brought back to the password panel for entry of a  
confirm password.  
User Response: Enter a password to be used for confirmation.  
A confirm password does not match password. Please retry.  
Explanation: A confirm password was entered that does not match the new  
password.  
System Action: Processing is brought back to the password panel for reentry of  
the confirm password.  
User Response: Reenter the confirm password and make sure that the confirm  
password is the same as the new password.  
ACO3862W  
ACO3863E  
The ADSMConnect Agent for Microsoft SQL Server is not properly installed.  
Some functions may not work properly. The product should be reinstalled.  
Explanation: An attempt was made to read the registry to determine where the  
SQL Agent was installed. This attempt failed.  
System Action: Processing ends.  
User Response: Reinstall the SQL Agent.  
There are no ADSM servers selected.  
Explanation: A request has been made, but there was no ADSM server selected.  
System Action: Processing ends.  
User Response: Select an ADSM server and reissue the request.  
Tivoli Storage Manager Messages  
1371  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3866I  
The default dsm entry is a requirement of the ADSM API and cannot be  
deleted.  
Explanation: An attempt was made to delete the dsm entry from the list of ADSM  
servers. The dsm entry must exist as a result of a requirement by the ADSM API.  
System Action: Processing ends. The GUI is displayed for further requests.  
User Response: None.  
ACO3869E  
ACO3870I  
A SQL server account name must be entered.  
Explanation: Before you can login to the SQL server, a SQL server account name  
must be entered. This account name is not known.  
System Action: Processing waits on the “SQL Server Login Information” panel.  
User Response: Enter the SQL server account name.  
Could not log on to SQL server. Please enter your SQL server connection  
information and try again.  
Explanation: An attempt was made to connect to the SQL server. This attempt  
failed as a result of not knowing all of the SQL Server login information.  
System Action: Process waits on the “SQL Server Login Information” panel.  
User Response: Enter the correct information on the “SQL Server Login  
Information” panel and try again.  
ACO3878I  
ACO3891I  
ACO3892I  
More than one version of a database (%1) is selected for restore. This will  
cause a redundant restore operation. Are you sure you want to continue?  
Explanation: An attempt was made to do a restore of the database in the message.  
However, more than one version was selected for restore.  
System Action: Processing waits for a “Yes” or “No” answer.  
User Response: Choose either “Yes”, and the restore of the redundant databases  
choices will occur, or “No” to cancel the operation.  
Cannot determine if the original database object (%1) has a separate  
transaction log. Would you like to display the list of potential target databases  
anyway?  
Explanation: An attempt was made to determine if the database object has an  
integrated log or not. This attempt failed.  
System Action: Processing waits until a “Yes” or “No” response is chosen.  
User Response: Choose either “Yes” or “No”.  
No database information is available. Please expand the tree view so that you  
see the list of individual databases.  
Explanation: This is an internal error with a database structure not being filled in  
correctly.  
System Action: Processing ends.  
User Response: Try to stop and restart the GUI and retry the operation.  
1372  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO3893I  
There are no existing databases with integrated transaction logs that are large  
enough to hold the data from %1. A database object that matches the original  
type and size must be created before a restore can be completed.  
Explanation: There are no databases with integrated transaction logs large enough  
to hold the data.  
System Action: Processing ends.  
User Response: A database object that matches the original type and size must be  
created before a restore can be completed.  
ACO3894I  
There are no existing databases without integrated transaction logs that are  
large enough to hold the data from %1. A database object that matches the  
original type and size must be created before a restore can be completed.  
Explanation: There are no databases without integrated transaction logs large  
enough to hold the data.  
System Action: Processing ends.  
User Response: A database object that matches the original type and size must be  
created before a restore can be completed.  
ACO3898I  
ACO3899E  
ACO3901E  
The date entered was not valid and has been modified, please verify.  
Explanation: The user entered an invalid ’Point in Time’ date that was  
automatically updated to be a valid date.  
System Action: Processing continues.  
User Response: Verify that the new ’Point in Time’ date is correct and continue  
processing accordingly.  
An internal error has occurred. The point in time restore date cannot be set.  
Explanation: An internal error has occurred that prevents the setting of the point  
in time restore “stop at” date. The point in time restore cannot be performed.  
System Action: Normal (non-point in time) restore processing continues.  
User Response: Attempt the point in time restore using the command line agent. If  
this problem still occurs contact IBM ADSM support.  
Base path cannot be located.  
Explanation: An attempt was made to start the ADSM help program for the SQL  
Connect Agent. This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the SQLDSM.HLP file exists in the appropriate  
directory. If it does not, you may want to reinstall the ADSMConnect Agent for  
Microsoft SQL Server.  
ACO3902E  
Failed to create winhelp process.  
Explanation: An attempt was made to show the SQLDSM.HLP file. This attempt  
failed.  
Tivoli Storage Manager Messages  
1373  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Action: Processing ends.  
User Response: Be sure that the SQLDSM.HLP file is installed to the appropriate  
directory. If not, it may be necessary to reinstall the agent code so that the registry  
is set up correctly.  
ACO4201E  
ACO4202E  
Remote error type detected in local error handler  
Explanation: An error was encountered with the ADSM API.  
System Action: Processing ends.  
User Response: Review the other messages regarding this error to get more  
information about the problem.  
Service error encountered, rc = %1!lu!  
Explanation: An attempt was made to either stop or open a Microsoft NT Service.  
This attempt has failed.  
System Action: Processing ends.  
User Response: Identify the problem further by checking the circumstances that  
generated this message and retry the operation.  
ACO4203E  
ACO4204W  
ACO4205E  
ACO4206E  
Timed out while attempting to logon to the ADSM server.  
Explanation: An attempt was made to logon to the ADSM Server. However, the  
connection was not made in the allowable time.  
System Action: Processing ends.  
User Response: Determine if the ADSM Server is up and running. If it is, try  
again. Otherwise, wait for the needed ADSM Server to be running.  
Available data exceeds the amount of available memory. Try reducing the  
amount of stored data.  
Explanation: There is more information than that which is shown. However, there  
is no available memory to receive the information.  
System Action: Processing continues with the incomplete information.  
User Response: Try to obtain more memory and retry the command.  
Timed out while attempting to logon to the SQL server.  
Explanation: An attempt was made to logon to the SQL Server. However, the  
connection was not made in the allowable time, which is 60 seconds.  
System Action: Processing ends.  
User Response: Determine if the SQL Server is up and running. If it is, try again.  
Otherwise, wait for the needed SQL Server to be running.  
Caught exception while issuing dsminit.  
Explanation: An attempt was made to run an initialization routine. This attempt  
failed.  
System Action: Processing ends.  
1374  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Response: Retry the operation. If the problem persists, please contact IBM  
ADSM support and indicate how this message was received.  
ACO4207E  
No matching objects were found.  
Explanation: An attempt was made to query a database object. This attempt failed  
as there were no objects found matching the input.  
System Action: Processing ends.  
User Response: Reenter the command indicating a database object that exists.  
ACO4208E  
ACO4209E  
A database name is required.  
Explanation: A database name is required to do the function requested.  
System Action: Processing ends.  
User Response: Reenter the command making sure that a database is specified.  
A named pipe name is required.  
Explanation: An attempt was made to do the requested function. However, the  
pipename to the SQL server is not set.  
System Action: Processing ends.  
User Response: Retry the operation. If the problem still occurs, contact IBM  
ADSM support and let them know how this error was obtained.  
ACO4210E  
Failed to connect to SQL server.  
Explanation: An attempt was made to connect to a SQL server. This attempt  
failed.  
System Action: Processing ends.  
User Response: There are several reasons why a connection could not be made to  
the SQL server:  
Insufficient memory  
Maximum number of connections to the SQL server have been reached  
SQL Server is unavailable or does not exist  
Login information is incorrect.  
Check which of these items caused the failure, and correct the problem.  
ACO4211E  
SQL EXEC failed.  
Explanation: An attempt was made to either use a SQL database or to send a  
command to the SQL server. This attempt failed.  
System Action: Processing ends.  
User Response: There could be a problem with the SQL Server permissions.  
Determine if this is the case. Retry the operation. If the problem still occurs contact  
IBM ADSM support and report how this error was obtained.  
Tivoli Storage Manager Messages  
1375  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO4212E  
ACO4213E  
ACO4214E  
ACO4215E  
ACO4216E  
An incremental backup cannot be performed because the named database does  
not have a separate transaction log.  
Explanation: An incremental backup was requested however the database does not  
have a separate transaction log.  
System Action: Processing ends.  
User Response: Only a full backup is allowed for this particular database.  
Could not build a SQL command.  
Explanation: An attempt was made to build a command to send to the SQL  
server. This attempt failed.  
System Action: Processing ends.  
User Response: Retry the operation. If the failure persists, contact IBM ADSM  
support and report how the error occurred.  
The input buffer was not large enough to hold the complete list of databases.  
Explanation: An attempt was made to get a list of the databases. This attempt  
failed as a result of a buffer being defined that was not large enough.  
System Action: Processing ends.  
User Response: Retry the operation. If the problem still occurs, contact IBM  
ADSM support and report how the error occurred.  
Unable to obtain attributes for the specified SQL database.  
Explanation: An attempt was made to get the attributes for a SQL database. This  
attempt failed.  
System Action: Processing ends.  
User Response: Stop and restart the SQL Server. Retry the operation. If the  
problem persists, contact IBM ADSM support and report how the error occurred.  
Could not connect to SQL Server. SQL server (%1) was not found on this  
machine.  
Explanation: An attempt was made to start the SQL Server listed in the message.  
This attempt failed.  
System Action: Processing ends.  
User Response: Be sure that the SQL server exists. Also, be sure that the  
SQLSERVR.EXE file exists.  
ACO4217E  
Unable to obtain the name of the local SQL server.  
Explanation: An attempt was made to get the name of the local SQL server. The  
attempt failed.  
System Action: Processing ends.  
User Response: Retry the operation. If the problem persists, contact IBM ADSM  
support and report how the error occurred.  
1376  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO4218E  
Could not open the ADSM client message file (dscameng.txt). Ensure that this  
file is installed in the correct location.  
Explanation: An attempt was made to send a command to the ADSM API.  
However, the API code could not find the dscameng.txt file.  
System Action: Processing ends.  
User Response: Make sure that the dscameng.txt file exists. If it does not, try  
reinstalling the product.  
ACO4219E  
Your ADSM password has expired. You can update your ADSM password from  
the Server | ADSM Server | Change password menu item.  
Explanation: An attempt was made to connect to the ADSM server. However, the  
attempt failed because the client node password has expired.  
System Action: Processing ends.  
User Response: The client node password needs to be changed. The message lists  
a method that can be used to update the password.  
ACO4227E  
ACO4228E  
No matching SQL databases were found.  
Explanation: An attempt was made to get a list of SQL databases. However, there  
were none found.  
System Action: Processing ends.  
User Response: Reenter the database name to one that exists.  
Error retrieving agent error code.  
Explanation: An error code was sent to the error handler that currently does not  
exist in the error handler routine.  
System Action: Processing ends.  
User Response: Retry the operation. If the error persists, contact IBM ADSM  
support and let them know how the error occurred.  
ACO4229E  
ACO4230E  
Unable to find system message.  
Explanation: An attempt was made to determine what the last system message  
was. This attempt failed.  
System Action: Processing ends.  
User Response: It is possible that the system dll is not current. Check and make  
certain that it is current.  
The start of the SQL server failed.  
Explanation: An attempt was made to start the SQL Server. This attempt failed.  
System Action: Processing ends.  
User Response: View the other messages for an indication as to the problem.  
Also, view the SQL Server Error Log as to an indication of what the problem may  
be.  
Tivoli Storage Manager Messages  
1377  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACO4231E  
ACO5201E  
ACO5202E  
ACO5203E  
An incremental restore cannot be performed because the named database does  
not have a separate transaction log.  
Explanation: An incremental restore was requested however the database does not  
have a separate transaction log.  
System Action: Processing ends.  
User Response: Only a full restore is allowed for this particular database.  
Could not open file %1.  
Explanation: An attempt was made to open the file listed in the message. This  
attempt failed.  
System Action: Processing ends.  
User Response: Determine if this file exists. Be sure that there is enough room for  
this file if it is being created.  
There is a syntax error on line %1!d! of the options file: %2 Line Contents:  
%3 You will need to correct the error before continuing.  
Explanation: While reading the options file, it was discovered that there was a  
syntax error. This error is listed in the message.  
System Action: Processing ends.  
User Response: Update the options file with the correct syntax.  
Error reading file: %1. Processing will not continue.  
Explanation: There was an attempt to read the file listed in the message. This  
attempt failed.  
System Action: Processing ends.  
User Response: Determine if the file is read-only. Determine if the file still exists.  
1378  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
Tivoli Data Protection for Oracle  
(0500–0599)  
ANS0500E  
ANS0501E  
ANS0502E  
ANS0503E  
ANS0504E  
Oracle passed invalid mode  
Explanation: Invalid mode passed by Oracle.  
System Action: The system returns to the calling procedure.  
User Response: Contact your system administrator.  
Oracle passed null file name  
Explanation: Null filename passed by Oracle.  
System Action: The system returns to the calling procedure.  
User Response: Contact your system administrator.  
Wrong data block size  
Explanation: Wrong Block Size  
System Action: The system returns to the calling procedure.  
User Response: Contact your system administrator.  
Object exists  
Explanation: Backup or Restore Object already exists.  
System Action: The system returns to the calling procedure.  
User Response: If backing up an object, be sure to generate a unique object name.  
Not same Oracle handle  
Explanation: The handle passed from Oracle is not the same handle that TSM  
passed back.  
System Action: The system returns to the calling procedure.  
User Response: Contact your system administrator.  
Tivoli Storage Manager Messages  
1379  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ANS0505E  
ANS0506E  
ANS0507E  
End of file reached  
Explanation: End of file reached.  
System Action: The system returns to the calling procedure.  
User Response: None  
Wrong Read State  
Explanation: The operation must be in READ state.  
System Action: The system returns to the calling procedure.  
User Response: Contact your service representative.  
Runtime API version is outdated  
Explanation: Runtime API is lower than compile time API.  
System Action: The system returns to the calling procedure.  
User Response: Use the WHAT command to find out the compile time API level.  
Obtain the same or higher level of API library.  
ANS0508E  
ANS0509E  
Wrong write state  
Explanation: The operation must be in WRITE state.  
System Action: The system returns to the calling procedure.  
User Response: Contact your service representative.  
Invalid flag passed  
Explanation: Invalid flag passed from Oracle.  
System Action: The system returns to the calling procedure.  
User Response: Contact your system administrator.  
1380  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V—Appendixes  
Tivoli Storage Manager Messages  
1381  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1382  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
Notices  
This information was developed for products and services offered in  
the U.S.A.  
IBM may not offer the products, services, or features discussed in  
this document in other countries. Consult your local IBM  
representative for information on the products and services currently  
available in your area. Any reference to an IBM product, program,  
or service is not intended to state or imply that only that IBM  
product, program, or service may be used. Any functionally  
equivalent product, program, or service that does not infringe any  
IBM intellectual property right may be used instead. However, it is  
the user’s responsibility to evaluate and verify the operation of any  
non-IBM product, program, or service.  
IBM may have patents or pending patent applications covering  
subject matter described in this document. The furnishing of this  
document does not give you any license to these patents. You can  
send license inquiries, in writing, to:  
IBM Director of Licensing  
IBM Corporation  
North Castle Drive  
Armonk, NY 10504-1785  
U.S.A.  
For license inquiries regarding double-byte (DBCS) information,  
contact the IBM Intellectual Property Department in your country or  
send inquiries, in writing, to:  
Tivoli Storage Manager Messages  
1383  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IBM World Trade Asia Corporation  
Licensing  
2-31 Roppongi 3-chome, Minato-ku  
Tokyo 106, Japan  
The following paragraph does not apply to the United Kingdom  
or any other country where such provisions are inconsistent with  
local law: INTERNATIONAL BUSINESS MACHINES  
CORPORATION PROVIDES THIS PUBLICATION “AS IS”  
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR  
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED  
WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY  
OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not  
allow disclaimer of express or implied warranties in certain  
transactions, therefore, this statement may not apply to you.  
This information could include technical inaccuracies or  
typographical errors. Changes are periodically made to the  
information herein; these changes will be incorporated in new  
editions of the publication. IBM may make improvements and/or  
changes in the product(s) and/or the program(s) described in this  
publication at any time without notice.  
Any references in this information to non-IBM Web sites are  
provided for convenience only and do not in any manner serve as an  
endorsement of those Web sites. The materials at those Web sites are  
not part of the materials for this IBM product and use of those Web  
sites is at your own risk.  
IBM may use or distribute any of the information you supply in any  
way it believes appropriate without incurring any obligation to you.  
Licensees of this program who wish to have information about it for  
the purpose of enabling: (i) the exchange of information between  
independently created programs and other programs (including this  
one) and (ii) the mutual use of the information which has been  
exchanged, should contact:  
IBM Corporation  
Information Enabling Requests  
1384  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dept. M13  
5600 Cottle Road  
San Jose CA 95193-0001  
U.S.A.  
Such information may be available, subject to appropriate terms and  
conditions, including in some cases, payment of a fee.  
The licensed program described in this information and all licensed  
material available for it are provided by IBM under terms of the  
IBM Customer Agreement, IBM International Program License  
Agreement, or any equivalent agreement between us.  
Information concerning non-IBM products was obtained from the  
suppliers of those products, their published announcements or other  
publicly available sources. IBM has not tested those products and  
cannot confirm the accuracy of performance, compatibility or any  
other claims related to non-IBM products. Questions on the  
capabilities of non-IBM products should be addressed to the  
suppliers of those products.  
This information contains examples of data and reports used in daily  
business operations. To illustrate them as completely as possible, the  
examples include the names of individuals, companies, brands, and  
products. All of these names are fictitious and any similarity to the  
names and addresses used by an actual business enterprise is entirely  
coincidental.  
If you are viewing this information softcopy, the photographs and  
color illustrations may not appear.  
Programming Interface  
This publication is intended to help the customer with the Tivoli  
Storage Manager messages.  
This publication documents information that is not intended to be  
used as programming interfaces of the Tivoli Storage Manager.  
Tivoli Storage Manager Messages  
1385  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Trademarks  
The following terms are trademarks of the International Business  
Machines Corporation in the United States or other countries or  
both:  
ACF/VTAM  
AD/Cycle  
ADSTAR  
ESCON  
Extended Services  
IBM  
Advanced Peer-to-Peer Networking IBMLink  
AIX  
Library Reader  
AIX/6000  
Application System/400  
APPN  
AS/400  
AT  
BookManager  
Bookshelf  
C/370  
MVS/ESA  
MVS/SP  
OpenEdition  
Operating System/2  
Operating System/400  
OS/2  
OS/390  
OS/400  
Common User Access  
CUA  
DATABASE 2  
DB2  
POWERparallel  
Proprinter  
RACF  
RISC System/6000  
RS/6000  
DFDSM  
DFSMS  
SP  
DFSMS/MVS  
DFSMS/VM  
DFSMSdss  
DFSMShsm  
DFSMSrmm  
ES/9000  
System/370  
System/390  
SystemView  
VM/ESA  
VTAM  
XT  
Lotus, Lotus 1–2–3, Lotus Approach, Lotus Domino and Lotus  
Notes are trademarks of Lotus Development Corporation in the  
United States and/or other countries.  
AFS and DFS are trademarks of Transarc Corporation in the United  
States and/or other countries.  
Tivoli and Tivoli ADSM are trademarks of Tivoli Systems Inc. in the  
United States and/or other countries.  
1386  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Microsoft, Win32, Windows, Windows NT, and the Windows 95  
logo are trademarks of Microsoft Corporation in the United States  
and/or other countries.  
UNIX is a registered trademark in the United States and/or other  
countries licensed exclusively through X/Open Company Limited.  
HP-UX is a trademark of Hewlett-Packard Company in the United  
States and/or other countries.  
Solaris is a trademark of Sun Microsystems, Inc. in the United States  
and/or other countries.  
Java and all Java-based trademarks and logos are trademarks of Sun  
Microsystems, Inc. in the United States and/or other countries.  
Intel is a registered trademark of the Intel Corporation in the United  
States and/or other countries.  
Other company, product, and service names may be trademarks or  
service marks of others.  
Tivoli Storage Manager Messages  
1387  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1388  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
Allocating Additional Server  
Memory  
If the server is low on memory, the following actions can be taken  
to allocate additional storage resource for the server:  
For AIX, ensure that there is sufficient paging space. You may  
also use SMIT to determine if the number of applications is  
causing a memory shortage.  
For VM, increase the size of the server’s virtual machine. This  
requires that the default storage size be updated in the server’s  
CP directory entry.  
For MVS, increase the size of the REGION parameter on the  
JOB or EXEC statement of the JCL used to start the server.  
A minimum size of 128M is recommended for TSM, but larger  
servers will require a larger region size.  
For Windows NT, the preferred method of solving a low  
memory condition is to add physical memory to the system.  
Otherwise, increase the amount of the system’s virtual memory.  
This can be done from the NT control panel by running the  
System applet and increasing the total paging file size.  
For HP-UX, ensure that there is sufficient paging space and that  
a sufficient amount of shared memory is available. For  
information on shared memory, refer to the Tivoli Storage  
ManagerQuick Start.  
Tivoli Storage Manager Messages  
1389  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
For Sun Solaris, ensure that there is sufficient paging space.  
Consult your Sun Solaris system documentation for details.  
For HP-UX and Sun Solaris, consider increasing the value of the  
MAXMEMORY option in the server options file and restart the  
server.  
Reduce the maximum number of client sessions permitted. To do  
this, update the value of the MAXSESSIONS parameter in the server  
options file and restart the server.  
Decrease the amount of space allocated to the server’s database or  
log buffer pool. To do this, update the value of the BUFPOOLSIZE  
or LOGPOOLSIZE parameters in the server options file and restart  
the server. Note that each page causes an additional 4K page to be  
allocated for the specified buffer pool. Reducing the pool sizes  
requires more I/O to service the same amount of data; some  
performance degradation may result.  
1390  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C
I/O Error Code Descriptions for  
Server Messages  
This section contains code descriptions for possible I/O error  
messages from the TSM server for the AIX and Windows NT  
operating systems.  
Code Description  
OP  
I/O operation that failed. Some possible values displayed are:  
READ  
WRITE  
FSR (forward space record)  
FSF (forward space file)  
WEOF (write end of file mark)  
A string of hex digits  
on page 1397 for a list of operation codes.  
CC  
I/O completion code. This value is returned by the device  
driver to the server when an error occurs. See “Completion  
completion codes. Refer to the IBM SCSI Tape Drive,  
Medium Changer, and Library Device Drivers: Installation  
and Users Guide for information on tape library system  
calls and error description for the library I/O control  
requests.  
KEY Byte 2 of the sense bytes from the error. The following lists  
some definitions:  
Tivoli Storage Manager Messages  
1391  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
0 = no additional sense bytes available  
1 = recovered error  
2 = not ready  
3 = medium error  
4 = hardware error  
5 = illegal request  
6 = unit attention (for example, a SCSI bus reset)  
7 = data protect  
8 = blank check  
9 = vendor specific  
A = copy aborted  
B = aborted command  
C = equal compare on SEARCH DATA command  
D = volume overflow  
E = miscompare  
F = reserved  
ASC/ASCQ  
Additional sense codes (ASC) and additional sense code  
qualifiers (ASCQ) are bytes 12 and 13 of the sense bytes.  
You should refer to the sense byte number along with the  
value for a complete description of the common values of  
the ASC and ASCQ codes. The drive or library reference  
manual provided with the device usually contain tables  
explaining the values of the KEY, ASC, and ASCQ fields.  
also provides additional information on the common values  
of ASC and ASCQ.  
Completion Code and Operation Code Values  
This section lists the completion code values for the following:  
All device classes  
Media changers  
Tape and optical drives  
This section lists the operation code values for tape library devices.  
for a description of the operation codes.  
1392  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Completion Code Values Common to All Device  
Classes  
The following table shows the completion code values, in decimal  
and hexadecimal numbers, common to all device classes. It provides  
a description for the I/O error message and the recommended action.  
After performing the recommended action, retry the failing  
operation. If the failing operation is not successful, contact TSM  
support.  
Table 2. Completion Code Values Common to All Device Classes  
Decimal  
Hexadecimal Description  
Recommended Action  
200  
X'C8'  
The device indicated a failure  
Retry the failing operation.  
condition, but sense data was  
unavailable.  
201  
202  
X'C9'  
X'CA'  
Device driver failure  
Contact TSM support.  
The device EEPROM failed.  
The device should be tested or  
serviced.  
203  
X'CB'  
Manual intervention required  
Correct the problem on the device.  
This may be a stuck tape, dirty  
heads or a jammed library arm.  
204  
205  
X'CC'  
X'CD'  
Recovered from an I/O error; for  
your information only  
No action necessary  
SCSI adapter failure  
Check for loose cables, bent pins,  
bad cables, bad SCSI adaptors,  
improper termination or bad  
terminators.  
206  
207  
208  
X'CE'  
X'CF'  
X'D0'  
General SCSI failure  
Check for loose cables, bent pins,  
bad cables, bad SCSI adaptors,  
improper termination or bad  
terminators.  
Device is not in a state capable of  
performing request  
Ensure the device is on and ready.  
Ensure the DEFINE DRIVE and  
DEFINE DEVCLASS have been  
issued properly.  
Command aborted  
Contact TSM support.  
Tivoli Storage Manager Messages  
1393  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 2. Completion Code Values Common to All Device Classes (continued)  
Decimal  
Hexadecimal Description  
Recommended Action  
209  
X'D1'  
X'D2'  
X'D3'  
Device microcode failure detected  
Check the microcode level of the  
drive. Call the drives manufacturer  
and request latest level.  
210  
211  
The device was reset due to device  
power-up, SCSI bus reset, or manual  
tape load/eject.  
Retry the failing operation.  
The SCSI bus was busy.  
Ensure the SCSI ids are correctly  
assigned to the correct device, and  
the device is not being accessed by  
another process.  
Completion Code Values for Media Changers  
The following table shows the completion code values, in decimal  
and hexadecimal numbers, for the media changers. It provides a  
description for the I/O error message and the recommended action.  
After performing the recommended action, retry the failing  
operation. If the failing operation is not successful, contact TSM  
support.  
Table 3. Completion Code Values for Media Changers  
Decimal  
Hexadecimal Description  
Recommended Action  
300  
X'12C'  
Cartridge entry/exit error  
Check the entry/exit ports for a  
jammed volume.  
301  
302  
X'12D'  
Cartridge load failure  
Check the drive for jammed  
volumes. On AIX, display the errpt  
to check for hardware errors.  
X'12E'  
Cartridge in failed drive  
Check the drive for jammed  
volumes. On AIX, display the errpt  
to check for hardware errors.  
303  
304  
X'12F'  
X'130'  
Carousel not loaded  
Changer failure  
Ensure the carousel is correctly in  
place and the door is shut.  
On AIX, display the errpt to check  
for hardware errors.  
1394  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 3. Completion Code Values for Media Changers (continued)  
Decimal  
Hexadecimal Description  
Recommended Action  
305  
X'131'  
Drive failure  
Ensure the heads have been cleaned.  
On AIX, display the errpt to check  
for hardware errors.  
306  
X'132'  
Drive or media failure  
Ensure the heads have been cleaned.  
On AIX, display the errpt to check  
for hardware errors.  
307  
308  
309  
X'133'  
X'134'  
X'135'  
Entry/exit failure  
Contact TSM support.  
Contact TSM support.  
Entry/exit port not present  
Library audit error  
Ensure that there are no jammed  
volumes. It is possible that the  
library audit is failing due to  
hardware errors. On AIX, display  
the errpt to check for hardware  
errors.  
310  
X'136'  
Library full  
Check for jammed volumes. Ensure  
the volumes have not been  
rearranged. If the library is not  
actually full, perform an AUDIT  
LIBRARY.  
311  
312  
X'137'  
X'138'  
Media export  
Slot failure  
Contact TSM support.  
Ensure that nothing is jammed in  
the slot.  
313  
X'139'  
Slot or media failure  
Ensure the volume is not jammed in  
the slot and that the volumes have  
not been rearranged. If problem  
persists, perform an AUDIT  
LIBRARY.  
314  
315  
X'13A'  
X'13B'  
The source slot or drive was empty  
in an attempt to move a volume.  
Ensure the volumes have not been  
rearranged. If problem persists,  
perform an AUDIT LIBRARY.  
The destination slot or drive was full Ensure the volumes have not been  
in an attempt to move a volume.  
rearranged, or that a volume is not  
stuck in the drive. If problem  
persists, perform an AUDIT  
LIBRARY.  
Tivoli Storage Manager Messages  
1395  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3. Completion Code Values for Media Changers (continued)  
Decimal  
Hexadecimal Description  
X'13C' Cleaner cartridge installed  
Recommended Action  
316  
Contact TSM support.  
Completion Code Values for Tape and Optical Drives  
The following table shows the completion code values, in decimal  
and hexadecimal numbers, for tape and optical drives. It provides a  
description for the I/O error message and the recommended action.  
After performing the recommended action, retry the failing  
operation. If the failing operation is not successful, contact TSM  
support.  
Table 4. Completion Code Values for Tape and Optical Drives  
Decimal  
Hexadecimal Description  
Recommended Action  
400  
X'190'  
Physical end of media encountered  
Ensure the heads are clean on the  
drive.  
402  
403  
X'192'  
Media corrupted  
Media failure.  
Ensure the heads are clean and the  
media is not physically damaged or  
too old.  
X'193'  
Ensure the heads are clean and the  
media is not physically damaged or  
too old.  
404  
406  
X'194'  
X'196'  
Media incompatibility  
Ensure the correct length and type  
of media is being used.  
Sector requested is invalid.  
Internal server error  
Contact TSM support.  
407  
408  
409  
X'197'  
X'198'  
X'199'  
Write protect  
Ensure the volume is not write  
protected.  
Clean the media and the drive.  
Media fault  
Clean the drive heads with a  
cleaning cartridge that is not too old  
Clean the heads and ensure the  
media is not physically damaged or  
too old.  
410  
X'19A'  
Cleaning complete  
Retry the failing operation.  
1396  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 4. Completion Code Values for Tape and Optical Drives (continued)  
Decimal  
Hexadecimal Description  
Recommended Action  
412  
X'19C'  
Media not present in drive  
Ensure the media is correctly  
positioned in the drive. If problem  
persists, perform an AUDIT  
LIBRARY.  
414  
415  
X'19E'  
X'19F'  
Erase failure  
Clean the drive heads.  
Internal server error  
Attempted to overwrite written  
WORM media  
Contact TSM support.  
416  
X'1A0'  
An incorrect length block was read.  
Ensure the heads are clean. On AIX,  
display the errpt to check for  
hardware errors.  
417  
418  
419  
X'1A1'  
X'1A2'  
X'1A2'  
Open read only  
Open write only  
Media scan failed  
Contact TSM support.  
Contact TSM support.  
Clean the drive and media.  
Operation Code Values for Tape Library Devices  
The following table shows the operation code values for tape library  
devices. The table provides the two least significant bytes of the  
operation code. Refer to the Tape Library System Calls chapter in  
the IBM SCSI Tape Drive, Medium Changer, and Library Device  
Drivers: Installation and Users Guide for detailed information on  
operation codes.  
Table 5. Operation Code Values for Tape Library Devices  
Hexadecimal  
X'6D31'  
Name  
Description  
MTIOCLM  
MTIOCLDM  
MTIOCLSVC  
MTIOCLQ  
Mount a volume on a specified drive.  
Demount a volume on a specified drive.  
Change the category of a specified volume.  
X'6D32'  
X'6D34'  
X'6D37'  
Return information about the tape library and  
its contents.  
X'6D38'  
MTIOCLQMID  
Query the status of the operation for a given  
message ID.  
Tivoli Storage Manager Messages  
1397  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 5. Operation Code Values for Tape Library Devices (continued)  
Hexadecimal  
Name  
Description  
X'6D38'  
MTIOCLQMID  
Query the status of the operation for a given  
message ID.  
X'6D39'  
MTIOCLSDC  
Assign a category to the automatic cartridge  
loader for a specified device.  
Common Values for ASC and ASCQ Codes  
This section provides descriptions for common values of the ASC  
and ASCQ codes, which are bytes 12 and 13 for SCSI-2 devices. For  
Windows NT, these codes also appear in the Event Log. See  
See server message ANR8300E or ANR8302E for the recommended  
action.  
The following table provides descriptions for common values of the  
ASC and ASCQ codes. Each value has a prefix of 0x, which  
indicates that it is a hexadecimal constant.  
Table 6. Common Values for ASC and ASCQ Codes  
ASC  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x02  
0x03  
0x03  
0x03  
0x04  
ASCQ  
0x00  
0x01  
0x02  
0x03  
0x04  
0x05  
0x06  
0x00  
0x00  
0x01  
0x02  
0x00  
Description  
No additional sense  
Filemark detected  
End-of-medium detected  
Setmark detected  
Beginning of medium  
End of data  
I/O process terminated  
No seek complete  
Device write fault  
No write current  
Excessive write errors  
Logical unit not ready  
1398  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 6. Common Values for ASC and ASCQ Codes (continued)  
ASC  
0x04  
0x04  
0x04  
0x04  
0x05  
0x06  
0x07  
0x08  
0x08  
0x08  
0x09  
0x0A  
0x0C  
0x11  
0x11  
0x11  
0x11  
0x11  
0x11  
0x11  
0x14  
0x14  
0x14  
0x14  
0x14  
0x15  
0x15  
0x15  
0x17  
0x17  
ASCQ  
0x01  
0x02  
0x03  
0x04  
0x00  
0x00  
0x00  
0x00  
0x01  
0x02  
0x00  
0x00  
0x00  
0x00  
0x01  
0x02  
0x03  
0x08  
0x09  
0x0A  
0x00  
0x01  
0x02  
0x03  
0x04  
0x00  
0x01  
0x02  
0x00  
0x01  
Description  
Becoming ready  
Not ready, initializing command required  
Not ready, manual intervention required  
Not ready, formatting  
No response to select  
No reference position found  
Multiple devices selected  
Communication failure  
Communication timeout  
Communication parity error  
Track following error  
Error log overflow  
Write error  
Unrecovered read error  
Read retries exhausted  
Error too long to correct  
Multiple read errors  
Incomplete block read  
No gap found  
Miscorrected error  
Recorded entity not found  
Record not found  
Filemark/setmark not found  
End-of-data not found  
Block sequence error  
Random positioning error  
Mechanical positioning error  
Read positioning error  
No error correction applied  
Recovered with retries  
Tivoli Storage Manager Messages  
1399  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 6. Common Values for ASC and ASCQ Codes (continued)  
ASC  
0x17  
0x17  
0x18  
0x1A  
0x1B  
0x20  
0x21  
0x21  
0x24  
0x25  
0x26  
0x26  
0x26  
0x26  
0x27  
0x28  
0x28  
0x29  
0x2A  
0x2A  
0x2A  
0x2B  
0x2C  
0x2D  
0x2F  
0x30  
0x30  
0x30  
0x30  
0x31  
ASCQ  
0x02  
0x03  
0x00  
0x00  
0x00  
0x00  
0x00  
0x01  
0x00  
0x00  
00  
Description  
Recovered with positive head offset  
Recovered with negative head offset  
ECC applied  
Parameter list length error  
Synchronous data transfer error  
Invalid operation code  
Block out of range  
Invalid element address  
Invalid field in CDB  
LUN not supported  
Invalid field in parameter list  
Parameter not supported  
Parameter value invalid  
Threshold parameters not supported  
Write protected  
0x01  
0x02  
0x03  
0x00  
0x00  
0x01  
0x00  
0x00  
0x01  
0x02  
0x00  
0x00  
0x00  
0x00  
0x00  
0x01  
0x02  
0x03  
0x00  
Not-ready to ready  
Import/export element accessed  
Power-on, reset, bus reset  
Parameters changed  
Mode parameters changed  
Log parameters changed  
Copy cannot execute  
Command sequence error  
Overwrite error on update  
Command cleared by initiator  
Incompatible media  
Media unknown format  
Media incompatible format  
Cleaning cartridge installed  
Media format corrupted  
1400  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 6. Common Values for ASC and ASCQ Codes (continued)  
ASC  
0x33  
0x37  
0x39  
0x3A  
0x3B  
0x3B  
0x3B  
0x3B  
0x3B  
0x3B  
0x3D  
0x3E  
0x3F  
0x3F  
0x3F  
0x3F  
0x43  
0x44  
0x45  
0x46  
0x47  
0x48  
0x49  
0x4A  
0x4B  
0x4C  
0x4E  
0x50  
0x50  
0x50  
ASCQ  
0x00  
0x00  
0x00  
0x00  
0x00  
0x01  
0x02  
0x08  
0x0D  
0x0E  
0x00  
0x00  
0x00  
0x01  
0x02  
0x03  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x01  
0x02  
Description  
Tape length error  
Rounded parameter  
Saving parameters not supported  
Medium not present  
Sequential positioning error  
Positioning error at BOT  
Positioning error at EOT  
Reposition error  
Medium destination element full  
Medium source element empty  
Invalid bits in message  
LUN not self-configured  
Operating conditions changed  
Microcode has been changed  
Changed operating definition  
Inquiry data has changed  
Message error  
Internal target failure  
Select/reselect failure  
Unsuccessful soft reset  
SCSI parity error  
Initiator detected message received  
Invalid message error  
Command phase error  
Data phase error  
LUN failed self-configuration  
Overlapped commands attempt  
Write append error  
Write append position error  
Position error (timing)  
Tivoli Storage Manager Messages  
1401  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 6. Common Values for ASC and ASCQ Codes (continued)  
ASC  
0x51  
0x52  
0x53  
0x53  
0x53  
0x5A  
0x5A  
0x5A  
0x5A  
0x5B  
0x5B  
0x5B  
0x5B  
ASCQ  
0x00  
0x00  
0x00  
0x01  
0x02  
0x00  
0x01  
0x02  
0x03  
0x00  
0x01  
0x02  
0x03  
Description  
Erase failure  
Cartridge fault  
Load/media eject failed  
Unload tape failure  
Media removal prevented  
Operator state changed  
Operator media removal  
Operator write protect  
Operator write permit  
Log exception  
Threshold condition met  
Log counter at maximum  
Log list codes exhausted  
Windows NT Event Log Entries  
The code values will appear as hexadecimal values in the Data area  
of the Windows NT Event Log. The Event Log omits the 0x prefix  
for the displayed information.  
In the NT Event Log, the entries with source AdsmScsi are produced  
by the AdsmScsi device driver. In these entries, byte 44 is the sense  
key, byte 43 is the ASC, and byte 42 is the ASCQ. (This is also true  
of entries logged by any of the NT tape device drivers.) If byte 44 is  
'ef', the error logged is not a check condition error. Examples of such  
errors are command timeouts or device selection errors.  
1402  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
D
Device Errors in AIX System  
Error Log  
TSM logs certain device errors in the AIX system error log. This  
section provides a brief description of the device error. It also  
provides the detail data and a description of the data. For a detailed  
description of the AIX error logging facility and of the information  
contained within an error report, refer to AIX Version 4 Problem  
Solving Guide and Reference.  
DEVICE ERROR and ERROR DESCRIPTION  
ADSM_DD_LOG1 (0xAC3AB953)  
DEVICE DRIVER SOFTWARE ERROR  
This error is logged by the ADSM device driver when a  
problem is suspected in the ADSM device driver software.  
For example, if the ADSM device driver issues a SCSI I/O  
command with an illegal operation code the command fails  
and the error is logged with this identifier. Report this error  
immediately to ADSM support personnel.  
Detail Data: Sense Data  
The sense data consists of information that can determine the  
cause of the error. All data in the error entry should be  
reported to ADSM support personnel.  
ADSM_DD_LOG2 (0x5680E405)  
HARDWARE/COMMAND-ABORTED ERROR  
Tivoli Storage Manager Messages  
1403  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
This error is logged by the ADSM device driver when the  
device reports a particular hardware error or  
command-aborted error in response to a SCSI I/O command.  
Detail Data: Sense Data  
The sense data consists of information that can determine the  
exact cause of the error; in this case, which hardware  
component failed and why. To interpret the sense data for a  
particular device, refer to the device’s SCSI specification  
manual.  
ADSM_DD_LOG3 (0x461B41DE)  
MEDIA ERROR  
This error is logged by the ADSM device driver when a  
SCSI I/O command fails because of corrupted or  
incompatible media, or because a drive requires cleaning.  
Detail Data: Sense Data  
The sense data consists of information that can determine the  
exact cause of the error. To interpret the sense data for a  
particular device, refer to the device’s SCSI specification  
manual.  
ADSM_DD_LOG4 (0x4225DB66)  
TARGET DEVICE GOT UNIT ATTENTION  
This error is logged by the ADSM device driver after  
receiving certain UNIT ATTENTION notifications from a  
device. UNIT ATTENTIONs are informational and usually  
indicate that some state of the device has changed. For  
example, this error would be logged if the door of a library  
device was opened and then closed again. Logging this event  
indicates that the activity occurred and that the library  
inventory may have been changed.  
Detail Data: Sense Data  
The sense data consists of information that describes the  
reason for the UNIT ATTENTION. To interpret the sense  
data for a particular device, refer to the device’s SCSI  
specification manual.  
1404  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADSM_DD_LOG5 (0xDAC55CE5)  
PERMANENT UNKNOWN ERROR  
This error is logged by the ADSM device driver after  
receiving an unknown error from a device in response to a  
SCSI I/O command. If the error persists, report it to ADSM  
support personnel.  
Detail Data: Sense Data  
The sense data consists of information that can determine the  
cause of the error. All data in the error entry should be  
reported to ADSM support personnel.  
Tivoli Storage Manager Messages  
1405  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1406  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E
Checklist for Contacting your  
Service Representative  
You should have the following information available when you  
contact your service representative for assistance. The problem call  
may be forwarded to the Tivoli Storage Manager Level 2 support  
group if the service representative cannot immediately resolve the  
problem. Therefore, keep the information available for possible  
future reference and as an aid in resolving the problem.  
1. Customer number  
2. Name of TSM product (for example, TSM for AIX)  
3. Platform, version, and release number of the TSM server’s  
operating system  
4. Version, release, modification, and service level number of the  
TSM server. You can obtain this information by typing  
QUERY STATUS from the TSM server console or  
administrative client.  
5. Platform, version, and release number of the TSM client’ s  
operating system  
6. Processor number such as type, model, and serial  
7. Component identification keyword  
8. Release level  
9. Current TSM service level (latest PTFs that have been applied)  
Tivoli Storage Manager Messages  
1407  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10. A brief description of the problem which includes the type of  
failure, abend codes, exception codes, message numbers and  
text, and routine names  
11. Version of the operating system you are running  
12. Name of the communication protocol, version and release  
number your installation is using  
13. System console log from around the time the problem occurred  
14. Dump information  
15. Activity log information  
16. Command text as entered  
17. Graphical user interface processing selections  
18. Client error log (DSMERROR.LOG)  
19. Messages in question  
20. For a documentation failure, the location of the error in the  
manual and a description of the problem it caused. Have the  
publication title and order number at hand.  
1408  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
The terms in this glossary are defined as they pertain to the Tivoli Storage Manager library. If you do  
not find the term you need, refer to the IBM Software Glossary on the Web at this URL:  
www.networking.ibm.com/nsg/nsgmain. You can also refer to IBM Dictionary of Computing, New York:  
McGraw-Hill, 1994.  
This glossary may include terms and definitions from:  
The American National Standard Dictionary for Information Systems, ANSI X3.172-1990,  
copyright (ANSI). Copies may be purchased from the American National Standards Institute, 11  
West 42nd Street, New York 10036.  
The Information Technology Vocabulary, developed by Subcommittee 1, Joint Technical Committee  
1, of the International Organization for Standardization and the International Electrotechnical  
Commission (ISO/IEC JTC2/SC1).  
A
absolute  
A value for the backup copy group mode indicating that a file is considered for  
incremental backup even if the file has not changed since the last backup. See also  
mode. Contrast with modified.  
access mode  
An attribute of a storage pool or a storage volume attribute that specifies whether  
TSM can write to or read from the storage pool or storage volume. The access  
mode can be read/write, read-only, or unavailable. Volumes in primary storage pools  
can also have an access mode of destroyed. Volumes in copy storage pools can also  
have an access mode of offsite.  
accounting facility  
A facility that records statistics about client session activity.  
accounting records  
Files that record session resource usage at the end of each client session.  
activate  
The process of validating the contents of a policy set and copying the policy set to  
the ACTIVE policy set.  
Tivoli Storage Manager Messages  
1409  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
active policy set  
The policy set that contains the policy rules currently in use by all client nodes  
assigned to the policy domain. The active policy set is the policy set that was most  
recently activated for the policy domain. See policy set.  
active version  
The most recent backup copy of a file stored by TSM. Such a file is not eligible for  
deletion until a backup process detects that the user has either replaced the file with  
a newer version, or has deleted the file from the workstation. Contrast with inactive  
version.  
activity log  
A log that records normal activity messages generated by the server. These messages  
include information about server and client operations, such as the start time of  
sessions or device I/O errors. Each message includes a message ID, date and time  
stamp, and a text description. The number of days to retain messages in the activity  
log can be specified.  
administrative client  
A program that runs on a file server, workstation, or mainframe that allows  
administrators to control and monitor the server through administrator commands.  
Contrast with backup-archive client.  
administrative command schedule  
A database record that describes the planned processing of an administrative  
command during a specific time period. See also client schedule.  
administrative privilege class  
A level of authority granted to an administrator of TSM. The privilege class  
determines which TSM administrative tasks the administrator can perform. For  
example, an administrator with system privilege class can perform any  
administrative task. See system privilege class, policy privilege class, storage  
privilege class, operator privilege class, and analyst privilege class.  
administrative session  
A period of time in which an administrator user ID communicates with a server to  
perform administrative tasks. Contrast with client node session.  
administrator  
A user who has been registered to the server. Administrators can be authorized to  
one or more of the following administrative privilege classes: system, policy,  
storage, operator, or analyst. Administrators can use the administrative commands  
and queries allowed by their privileges.  
Advanced Interactive Executive (AIX)  
An operating system used in the RISC System/6000® computers. The AIX operating  
system is the IBM implementation of the UNIX® operating system.  
1410  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Peer-to-Peer Networking® (APPN®)  
An extension to the LU6.2 peer orientation for end-user services. See SNA LU6.2  
and Systems Network Architecture.  
Advanced Program-to-Program Communication (APPC)  
An implementation of the SNA/SDLC LU6.2 protocol that allows interconnected  
systems to communicate and share the processing of programs. See SNA LU6.2,  
Systems Network Architecture, and Common Programming Interface  
Communications.  
AFS  
Andrew file system.  
aggregate file  
A file, stored in one or more storage pools, consisting of a group of logical files  
packaged together. See logical file and physical file.  
AIX  
Advanced Interactive Executive.  
analyst privilege class  
An administrative privilege class that allows an administrator to reset statistics.  
Andrew file system (AFS)  
A distributed file system developed for UNIX operating systems.  
API  
Application program interface.  
APPC  
Advanced Program-to-Program Communication.  
application client  
One of the Tivoli Data Protection for application programs installed on a system.  
The Tivoli Storage Manager server provides backup services to these clients.  
APPN  
Advanced Peer-to-Peer Networking.  
archive  
A function that allows users to copy one or more files to a storage pool for  
long-term storage. Archive copies may be accompanied by descriptive information  
and may be retrieved by archive date, by file name, or by description. Contrast with  
retrieve.  
archive copy  
A user file that has been archived to a TSM storage pool.  
Tivoli Storage Manager Messages  
1411  
Download from Www.Somanuals.com. All Manuals Search And Download.  
archive copy group  
A policy object containing attributes that control the generation, destination, and  
expiration of archive files. An archive copy group belongs to a management class.  
archive retention grace period  
The number of days that TSM retains an archive copy when the server is unable to  
rebind the file to an appropriate management class.  
AS/400  
Application System/400®.  
assigned capacity  
The portion of available space that can be used to store database or recovery log  
information. See also available space.  
association  
(1) The defined relationship between a client node and a client schedule. An  
association identifies the name of a schedule, the name of the policy domain to  
which the schedule belongs, and the name of a client node that performs scheduled  
operations. (2) On a configuration manager, the defined relationship between a  
profile and an object such as a policy domain. Profile associations define the  
configuration information that will be distributed to managed servers when they  
subscribe to the profile.  
audit  
The process of checking for logical inconsistencies between information that the  
server has and the actual condition of the system. TSM has processes for auditing  
volumes, the database, libraries, and licenses. For example, in auditing a volume  
TSM checks for inconsistencies between information about backed up or archived  
files stored in the database and actual data associated with each backup version or  
archive copy in server storage.  
authentication  
The process of checking a user’s password before allowing that user access to the  
server. Authentication can be turned on or off by an administrator with system  
privilege.  
authority  
The right granted to a user to perform tasks with TSM servers and clients. See  
administrative privilege class.  
autochanger  
A small multislot tape device that has a mechanism that automatically puts tape  
cartridges into the tape drive or drives. Also called medium or media changer, or a  
library.  
1412  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
availability management  
Managing recovery from relatively common computer system outages such as a disk  
drive head crash. Recovery is often accomplished by using disk mirroring and other  
forms of RAID technology, or by maintaining onsite backup copies of data.  
available space  
The amount of space, in megabytes, that is available to the database and recovery  
log. This space can be used to extend the capacity of the database or recovery log,  
or to provide sufficient free space before a volume is deleted from the database or  
recovery log.  
awk  
In AIX, a pattern-matching program for processing text files. With the DRM  
product, you can use an awk script to break up the disaster recovery plan file into  
usable parts.  
B
background process  
A server process that runs in the background, allowing the administrative session to  
be used for other work.  
backup  
The process of copying information for safekeeping. TSM has processes for backing  
up user files, the TSM database, and storage pools. For example, users can back up  
one or more files to a storage pool to ensure against loss of data. Contrast with  
restore. See also database backup series and incremental backup.  
backup-archive client  
A program that runs on a workstation or file server and provides a means for users  
to back up, archive, restore, and retrieve files. Contrast with administrative client.  
backup copy  
A user file that has been backed up to a TSM storage pool.  
backup copy group  
A policy object containing attributes that control the generation, destination, and  
expiration of backup files. A backup copy group belongs to a management class.  
backup retention grace period  
The number of days that TSM retains a backup version after the server is unable to  
rebind the file to an appropriate management class.  
backup series  
See database backup series.  
Tivoli Storage Manager Messages  
1413  
Download from Www.Somanuals.com. All Manuals Search And Download.  
backup set  
A portable, consolidated group of active backup files for a single client. Generation  
of a backup set is possible for selected backup-archive clients that obtain services  
from a server at the latest software level.  
backup version  
A file, directory, or file space that a user has backed up, which resides in TSM  
server storage. There may be more than one backup version of a file in the storage  
pool, but at most only one is an active backup version. See active version and  
inactive version.  
binding  
The process of associating a file with a management class name. See rebinding.  
boot media  
Media that contains operating system and other files essential to running a  
workstation or server.  
buffer  
Storage used to compensate for differences in the data rate flow, when transferring  
data from one device to another.  
buffer pool  
Temporary space used by the server to hold database or recovery log pages. See  
database buffer pool and recovery log buffer pool.  
C
cache  
The process of leaving a duplicate copy on random access media when the server  
migrates a file to another storage pool in the hierarchy.  
CARTRIDGE  
On TSM servers that support it, a device class that is used to categorize tape  
devices that support tape cartridges, such as the 3490 Magnetic Tape Subsystem.  
cartridge system tape (CST)  
The base tape cartridge media used with 3480 or 3490 Magnetic Tape Subsystems.  
When specified as a media type in TSM, CST identifies standard length tape.  
Contrast with enhanced capacity cartridge system tape.  
central scheduler  
A function that allows an administrator to schedule client operations and  
administrative commands. The operations can be scheduled to occur periodically or  
on a specific date. See client schedule and administrative command schedule.  
1414  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CID  
Configuration Installation and Distribution.  
client  
A program running on a PC, workstation, file server, LAN server, or mainframe that  
requests services of another program, called the server. The following types of  
clients can obtain services from a TSM server: administrative client, application  
client, API client, backup-archive client, HSM client (also known as space manager  
client), and host server.  
Client Access/400®  
A software product that supports advanced program-to-program communications  
(APPC) in the DOS, OS/2®, and Microsoft Windows® environments and provides a  
set of end user services.  
client domain  
The set of drives, file systems, or volumes selected by a backup-archive client user  
during a backup or archive operation.  
client migration  
The process of copying a file from a client node to TSM storage and replacing the  
file with a stub file on the client node. The process is controlled by the user and by  
space management attributes in the management class. See also space management.  
client node  
A file server or workstation on which the backup-archive client program has been  
installed, which has been registered to the server.  
client node session  
A period of time in which a user communicates with a server to perform backup,  
restore, archive, retrieve, migrate, or recall requests. Contrast with administrative  
session.  
client options file  
A file that a client can change, containing a set of processing options that identify  
the server, communication method, and options for backup, archive, hierarchical  
storage management, and scheduling. Also called the dsm.opt file.  
client polling scheduling mode  
A client/server communication technique where the client queries the server for  
work.  
client schedule  
A database record that describes the planned processing of a client operation during  
a specific time period. The client operation can be a backup, archive, restore, or  
retrieve operation, a client operating system command, or a macro. See also  
administrative command schedule.  
Tivoli Storage Manager Messages  
1415  
Download from Www.Somanuals.com. All Manuals Search And Download.  
client/server  
A system architecture in which one or more programs (clients) request computing or  
data services from another program (server).  
client system options file  
A file, used on UNIX clients, containing a set of processing options that identify the  
TSM servers to be contacted for services. This file also specifies communication  
methods and options for backup, archive, hierarchical storage management, and  
scheduling. Also called the dsm.sys file. See also client user options file.  
client user options file  
A user-created file, used on UNIX clients, containing a set of processing options  
that identify the server, communication method, backup and archive options, space  
management options, and scheduling options. Also called the dsm.opt file. See also  
client system options file.  
closed registration  
A registration process in which an administrator must register workstations as client  
nodes with the server. Contrast with open registration.  
collocation  
A process that attempts to keep all data belonging to a single client node or a single  
client file space on a minimal number of sequential access media volumes within a  
storage pool. Collocation can reduce the number of volumes that must be accessed  
when a large amount of data must be restored.  
commit  
To make changes permanent in the database. Changes made to the database files are  
not permanent until they are committed.  
Common Programming Interface Communications (CPI-C)  
A programming interface that allows program-to-program communication using  
SNA LU6.2. See also Systems Network Architecture.  
Common User Access® (CUA®)  
Guidelines for the dialog between a human and a workstation or terminal. One of  
the three Systems Application Architecture areas.  
communication manager  
A component of OS/2 that allows a workstation to connect to a host computer and  
use the host resources as well as the resources of other personal computers to which  
the workstation is attached, either directly or through a host.  
communication method  
The method used by a client and server for exchanging information.  
communication protocol  
A set of defined interfaces that allow computers to communicate with each other.  
1416  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
compression  
The process of saving storage space by eliminating empty fields or unnecessary data  
in a file. In TSM, compression can occur at a workstation before files are backed up  
or archived to server storage. On some types of tape drives, hardware compression  
can be used.  
Configuration Installation and Distribution (CID)  
The term used to describe the capability of IBM products for automated installation.  
CID-enabled products are capable of unattended, remote installation.  
configuration manager  
One TSM server that distributes configuration information to other TSM servers  
(called managed servers) via profiles. Configuration information can include policy  
and schedules. See managed server and profile.  
copy group  
A policy object that contains attributes that control the generation, destination, and  
expiration of backup and archive files. There are two kinds of copy groups: backup  
and archive. Copy groups belong to management classes. See also frequency,  
destination, mode, serialization, retention, and version.  
copy status  
The status of volume copies defined to the database or recovery log. The copy  
status can be synchronized, stale, off-line, or undefined.  
copy storage pool  
A named set of volumes that contains copies of files that reside in primary storage  
pools. Copy storage pools are used only to back up the data stored in primary  
storage pools. A copy storage pool cannot be a destination for a backup copy group,  
an archive copy group, or a management class (for space-managed files). See  
primary storage pool and destination.  
CPI-C  
Common Programming Interface Communications.  
CST  
Cartridge system tape.  
CUA  
Common User Access.  
D
daemon  
In the AIX operating system, a program that runs unattended to perform a standard  
service. Some daemons are triggered automatically to perform their tasks; others  
operate periodically.  
Tivoli Storage Manager Messages  
1417  
Download from Www.Somanuals.com. All Manuals Search And Download.  
daemon process  
In the AIX operating system, a process begun by the root user or by the root shell  
that can be stopped only by the root user. Daemon processes generally provide  
services that must be available at all times, such as sending data to a printer.  
damaged file  
A physical file for which TSM has detected read errors.  
DASD  
Direct access storage device.  
database  
A collection of information about all objects managed by the server, including  
policy management objects, users and administrators, and client nodes.  
database audit  
A utility that checks for and optionally corrects inconsistent database references.  
database backup series  
One full backup of the database, plus up to 32 incremental backups made since that  
full backup. Each full backup that is run starts a new database backup series. A  
backup series is identified with a number.  
database backup trigger  
A set of criteria that defines when and how database backups are run automatically.  
The criteria determine how often the backup is run, whether the backup is a full or  
incremental backup, and where the backup is stored.  
database buffer pool  
Storage that is used as a cache to allow database pages to remain in memory for  
long periods of time, so that the server can make continuous updates to pages  
without requiring input or output (I/O) operations from external storage.  
database dump  
The action performed by the DSMSERV DUMPDB utility (DMPADSM command  
on AS/400), which copies TSM database entries to media for later reload in case a  
catastrophic error occurs.  
database load  
The action performed by the DSMSERV LOADDB utility (LODADSM command  
on AS/400), which copies TSM database entries from media to a newly installed  
database.  
database snapshot  
A function of TSM that backs up the entire TSM database to media that can be  
taken off-site. The database snapshot does not interrupt any database backup series  
and cannot have incremental database backups associated with it. Contrast with full  
backup.  
1418  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
database volume  
A volume that has been assigned to the TSM database.  
dataserver  
See Tape Library Dataserver.  
data set  
See linear data set.  
DDM  
Distributed Data Management.  
default management class  
A management class assigned to a policy set, which is used to govern backed up or  
archived files when a user does not specify a management class for a file.  
deletion exit  
For MVS or VM, an installation-wide exit that informs a tape management system  
or operator that the server has deleted a sequential access media volume from its  
database.  
delimiter  
(1) A character used to indicate the beginning and end of a character string. (2) A  
character that groups or separates words or values in a line of input.  
desktop client  
The group of backup-archive clients supported by TSM that includes clients on  
OS/2, DOS, Windows, Apple, and Novell NetWare operating systems.  
destination  
A copy group or management class attribute that specifies the primary storage pool  
to which a client file will be backed up, archived, or migrated.  
device class  
A named group of storage devices with common characteristics. Each device class  
has a unique name and represents a device type of disk, file, optical disk, or tape.  
device configuration file  
A file that contains information about defined device classes, and, on some TSM  
servers, defined libraries and drives. The file can be created by using a TSM  
command or by using an option in the server options file. The information is a copy  
of the device configuration information in the TSM database.  
device driver  
A collection of subroutines that control the interface between I/O device adapters  
and the processor.  
Tivoli Storage Manager Messages  
1419  
Download from Www.Somanuals.com. All Manuals Search And Download.  
device type  
A category of storage device. Each device class is categorized with one of the  
supported device types, for example, DISK or CARTRIDGE.  
direct access storage device (DASD)  
A device in which access time is effectively independent of the location of the data.  
disaster recovery  
Recovery from catastrophic interruptions of computer systems, such as loss of the  
system location because of natural events. Backup data is kept offsite to protect  
against such catastrophes.  
Disaster Recovery Manager  
See Tivoli Disaster Recovery Manager.  
disaster recovery plan  
A document that contains information about how to recover computer systems if a  
disaster occurs. The Tivoli Disaster Recovery Manager (DRM) product allows you  
to create the plan for a TSM server. The plan is a file that contains information  
about the software and hardware used by the TSM server, and the location of  
recovery media.  
DISK  
A device class that is defined by TSM at installation. It is used to categorize disk  
drives, such as internal disk drives or 3390 DASD.  
disk operating system (DOS)  
An operating system used in IBM PC, PS/2, and compatible computers.  
Distributed Data Management (DDM)  
A feature of the System Support Program Product that allows an application  
program (client) to use server program functions to work on files that reside in a  
remote system.  
DLL  
Dynamic link library.  
DLT  
Digital linear tape.  
domain  
See policy domain or client domain.  
DOS  
Disk operating system.  
1420  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
drive  
DRM  
A device used to read and write data on a medium such as a magnetic disk, optical  
disk, or tape.  
A short name for Tivoli Disaster Recovery Manager.  
dsm.opt file  
See client options file and client user options file.  
dsmserv.opt  
See server options file.  
dsm.sys file  
See client system options file.  
dynamic  
A copy group serialization value that specifies that TSM accepts the first attempt to  
back up or archive a file regardless of whether the file is modified during the  
backup or archive process. See also serialization. Contrast with shared dynamic,  
shared static, and static.  
dynamic link library  
A file containing executable code and data bound to a program at load time or run  
time, rather than during linking. The code and data in a dynamic link library can be  
shared by several applications simultaneously.  
E
ECCST  
Enhanced capacity cartridge system tape.  
enhanced capacity cartridge system tape (ECCST)  
Cartridge system tape with increased capacity that can only be used with 3490E  
tape subsystems. Contrast with cartridge system tape.  
enterprise configuration  
A capability that allows the administrator to distribute the configuration of one TSM  
server to other servers using server-to-server communication. See configuration  
manager, managed server, profile, and subscription.  
enterprise logging  
The sending of events from TSM servers to a designated event server. The event  
server routes the events to designated receivers, such as to a user exit. See also  
event.  
Tivoli Storage Manager Messages  
1421  
Download from Www.Somanuals.com. All Manuals Search And Download.  
error log  
A character file written on random access media that contains information about  
errors detected by the server or client.  
estimated capacity  
The available space, in megabytes, of a storage pool.  
Ethernet  
A data link protocol and LAN that interconnects personal computers and  
workstations via coaxial cable.  
event  
(1) An administrative command or a client operation that is scheduled to be run  
using TSM scheduling. (2) A message that a TSM server or client issues. Messages  
can be logged using TSM event logging.  
event record  
A database record that describes actual status and results for events.  
event server  
A server to which other servers can send events for logging. The event server routes  
the events to any receivers that are enabled for the sending server’s events.  
exclude  
The process of identifying files or directories in an include-exclude list to prevent  
these objects from being backed up whenever a user or schedule issues an  
incremental or selective backup operation, or to prevent these objects from being  
migrated off the client node via Tivoli Space Manager space management.  
exclude-include list  
See include-exclude list.  
exit  
To execute an instruction within a portion of a computer program in order to  
terminate the execution of that portion.  
exit machine  
On a VM server, a virtual machine that runs the mount and deletion  
installation-wide exits on VM systems.  
expiration  
The process by which files are identified for deletion because their expiration date  
or retention period has passed. Backed up or archived files are marked expired by  
TSM based on the criteria defined in the backup or archive copy group.  
expiration date  
On MVS, VM, and VSE servers, a device class attribute used to notify tape  
management systems of the date when TSM no longer needs a tape volume. The  
1422  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
date is placed in the tape label so that the tape management system does not  
overwrite the information on the tape volume before the expiration date.  
export  
The process of copying administrator definitions, client node definitions, policy  
definitions, server control information or file data to external media.  
export/import facility  
See import/export facility.  
extend  
The process of increasing the portion of available space that can be used to store  
database or recovery log information. Contrast with reduce.  
F
file record extent  
The extent of the file enumerated in number of records.  
file space  
A logical space in a client’s storage that can contain a group of files. For clients on  
systems such as OS/2, a file space is a logical partition and is identified by a  
volume label. For clients on systems such as AIX and UNIX, a file space can  
consist of any subset of directories and subdirectories stemming from a virtual  
mount point. Clients can restore, retrieve, or delete their file spaces from TSM  
server storage. TSM does not necessarily store all the files from a single file space  
together, but can identify all the files in server storage that came from a single file  
space.  
File Transfer Protocol (FTP)  
In TCP/IP, the protocol that makes it possible to transfer data among hosts and to  
use foreign hosts indirectly.  
format  
A device class attribute that specifies the recording format used to read or write to  
sequential access media such as tape.  
frequency  
A copy group attribute that specifies the minimum interval, in days, between  
incremental backups.  
FTP  
File Transfer Protocol.  
Tivoli Storage Manager Messages  
1423  
Download from Www.Somanuals.com. All Manuals Search And Download.  
full backup  
A function of TSM that copies the entire database. A full backup begins a new  
database backup series. Contrast with incremental backup and database snapshot.  
See database backup series.  
fuzzy copy  
A backup version or archive copy of a file that might not accurately reflect what is  
currently in the file because TSM backed up or archived the file while the file was  
being modified.  
G
H
GUI  
Graphical user interface.  
Head-disk assembly.  
HDA  
head-disk assembly (HDA)  
A field replaceable unit in a direct access storage device containing the disks and  
actuators.  
hierarchical storage management (HSM) client  
The Tivoli Space Manager program that runs on workstations to allow users to  
maintain free space on their workstations by migrating and recalling files to and  
from Tivoli Storage Manager storage. Synonymous with space manager client.  
high migration threshold  
A percentage of the storage pool capacity that identifies when TSM can start  
migrating files to the next available storage pool in the hierarchy. Contrast with low  
migration threshold. See server migration.  
host server  
The name for the system on which the Tivoli Data Protection for Workgroups  
program runs. The host server obtains scheduling services from Tivoli Storage  
Manager.  
HP-UX  
Hewlett-Packard UNIX operating system.  
HSM client  
Hierarchical storage management client. Also known as the space manager client.  
1424  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I
import  
The process of copying exported administrator definitions, client node definitions,  
policy definitions, server control information or file data from external media to a  
target server.  
import/export facility  
The facility that allows system administrators to copy definitions and file data from  
a source server to external media to move or copy information between servers. A  
subset of information can be imported to a target server from the external media.  
inactive version  
A backup version of a file for which a more recently backed-up version exists.  
Inactive backup versions are eligible for expiration processing according to the  
management class assigned to the file. Contrast with active version.  
include-exclude file  
On UNIX clients, a file containing statements that TSM uses to determine whether  
to back up or migrate certain files, and to determine the associated management  
classes to use for backup, archive, and space management. See include-exclude list.  
include-exclude list  
A group of include and exclude option statements in a file. TSM uses the statements  
to determine whether to back up or migrate certain files, and to determine the  
associated management classes to use for backup, archive, and space management.  
The exclude options identify files that should not be backed up or migrated off the  
client node. The include options identify files that are exempt from the exclusion  
rules, or assign a management class to a file or group of files for backup, archive,  
or space management services. The include-exclude list is defined either in the  
include-exclude file (for UNIX clients) or in the client options file (for other  
clients).  
incremental backup  
(1) A function that allows users to back up files or directories that are new or have  
changed since the last incremental backup. With this function, users can back up  
files or directories from a client domain that are not excluded in the include-exclude  
list and that meet the requirements for frequency, mode, and serialization as defined  
in the backup copy group of the management class assigned to the files. Contrast  
with selective backup. (2) A function of TSM that copies only the pages in the  
database that are new or changed since the last full or incremental backup of the  
database. Contrast with full backup. See database backup series.  
internal mounting facility  
On a VM server, a VM facility that allows the server to request tape mounts by  
sending a message to a mount operator. The message is repeated until the tape is  
mounted or until the mount wait time is exceeded.  
Tivoli Storage Manager Messages  
1425  
Download from Www.Somanuals.com. All Manuals Search And Download.  
inter-user communication vehicle (IUCV) facility  
On a VM server, a VM communication method used to pass data between virtual  
machines and VM components.  
IPX/SPX  
Internetwork Packet Exchange/Sequenced Packet Exchange. IPX/SPX is Novell  
NetWare’s communication protocol.  
IUCV  
Inter-user communication vehicle.  
K
KB  
Kilobyte.  
kernel  
The part of an operating system that performs basic functions such as allocating  
hardware resources.  
kernel extension  
A program that modifies parts of the kernel that can be customized to provide  
additional services and calls. See kernel.  
kilobyte (KB)  
1024 bytes.  
L
LAN  
Local area network.  
length  
A device class attribute that specifies the length of cartridge tape by specifying one  
of the following media types: CST for standard length tape or ECCST for double  
length tape.  
library  
(1) A repository for demountable recorded media, such as magnetic tapes. (2) For  
TSM, a collection of one or more drives, and possibly robotic devices (depending  
on the library type), which can be used to access storage volumes. (3) In the AS/400  
system, a system object that serves as a directory to other objects. A library groups  
related objects, and allows the user to find objects by name.  
1426  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
linear data set  
A type of MVS data set that TSM uses for the database, the recovery log, and  
storage pools. The data set must be preallocated using VSAM IDCAMS and  
formatted by TSM for its use.  
load  
See mount.  
local area network (LAN)  
A network in which a set of devices are connected to one another for  
communication and that can be connected to a larger network.  
logical file  
A client file stored in one or more server storage pools, either by itself or as part of  
an aggregate file. See also aggregate file and physical file.  
logical occupancy  
The space required for the storage of logical files in a storage pool. Because logical  
occupancy does not include the unused space created when logical files are deleted  
from aggregates, it may be less than physical occupancy. See also physical file and  
logical file.  
logical volume  
(1) A portion of a physical volume that contains a filesystem. (2) For the TSM  
server, the combined space from all volumes defined to either the database or the  
recovery log. The database is one logical volume and the recovery log is one logical  
volume.  
log pool size  
The size of an area in memory used to store recovery log pages.  
low migration threshold  
A percentage of the storage pool capacity that specifies when TSM can stop the  
migration of files to the next storage pool. Contrast with high migration threshold.  
See server migration.  
M
machine information  
Details about the machine on which a client node resides.  
macro file  
A file that contains one or more administrative commands and that is run from an  
administrative client. Contrast with TSM command script.  
Tivoli Storage Manager Messages  
1427  
Download from Www.Somanuals.com. All Manuals Search And Download.  
managed object  
A definition in the TSM database of a managed server that was distributed to the  
managed server by a configuration manager. In general, the definition cannot be  
modified locally on the managed server. When a managed server subscribes to a  
profile, all objects associated with that profile become managed objects in the  
database of the managed server. Objects can include policy, schedules, client options  
sets, server scripts, administrator registrations, and server and server group  
definitions.  
managed server  
A TSM server that receives configuration information from a configuration manager  
via subscription to one or more profiles. Configuration information can include  
definitions of objects such as policy and schedules. See configuration manager,  
subscription, and profile.  
management class  
A policy object that users can bind to each file to specify how the server manages  
the file. The management class can contain a backup copy group, an archive copy  
group, and space management attributes. The copy groups determine how the TSM  
server manages backup versions or archive copies of files. The space management  
attributes determine whether files are eligible for migration from space manager  
client nodes to TSM storage, and under what conditions. See also copy group,  
binding and rebinding.  
mask  
A pattern of characters that controls the keeping, deleting, or testing of positions of  
another pattern of characters or bits.  
maximum extension  
Specifies the maximum amount of storage space, in megabytes, that you can extend  
the database or recovery log.  
maximum reduction  
Specifies the maximum amount of storage space, in megabytes, that you can reduce  
the database or recovery log.  
maximum utilization  
The highest percentage of assigned capacity used by the database or recovery log.  
MB  
Megabyte.  
megabyte (MB)  
(1) For processor storage and real and virtual memory, 220 or 1 048 576 bytes. (2)  
For disk storage capacity and transmission rates, 1 000 000 bytes.  
1428  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
migrate  
(1) To move data from one storage pool to the storage pool specified as the next  
pool in the hierarchy. The process is controlled by the high and low migration  
thresholds for the first storage pool. See high migration threshold and low migration  
threshold. (2) To copy a file from a Tivoli Space Manager client node to TSM  
storage. Tivoli Space Manager replaces the file with a stub file on the client node.  
The process is controlled by the include-exclude list and by space management  
attributes in management classes.  
migration  
The process of moving data from one storage location to another. See client  
migration and server migration.  
minidisk  
A logical subdivision of a VM physical disk that provides storage on contiguous  
cylinders of DASD. On a VM server, a minidisk can be defined as a disk volume  
that can be used by the database, recovery log, or a storage pool.  
mirroring  
A feature that protects against data loss within the database or recovery log by  
writing the same data to multiple disks at the same time. Mirroring supports up to  
three exact copies of each database or recovery log volume.  
mm  
Millimeter.  
mode  
A copy group attribute that specifies whether to back up a file that has not been  
modified since the last time the file was backed up. See modified and absolute.  
modified  
A backup copy group mode value indicating that a file is considered for incremental  
backup only if it has changed since the last backup. A file is considered changed if  
the date, size, owner, or permissions have changed. See mode. Contrast with  
absolute.  
Motif  
A graphical user interface that performs window management and contains a high  
level toolkit for application program development. It provides an icon view of the  
UNIX file system. Also known as X-Windows/Motif or Motif X—Toolkit.  
mount  
To place a data medium (such as a tape cartridge) on a drive in a position to  
operate.  
Tivoli Storage Manager Messages  
1429  
Download from Www.Somanuals.com. All Manuals Search And Download.  
mount exit  
On a VM server, an installation-wide exit (DSMMOUNT EXEC) that requests tape  
mounts on behalf of the server on VM systems.  
mount limit  
A device class attribute specifying the maximum number of volumes that can be  
simultaneously accessed from the same device class, that is, the maximum number  
of mount points. See mount point.  
mount operator  
On a VM server, a VM user ID that can receive tape mount messages from the  
server.  
mount point  
A logical drive through which TSM accesses volumes in a sequential access device  
class. For a device class with a removable media device type (for example,  
CARTRIDGE), a mount point is a logical drive associated with a physical drive. For  
a device class with the device type of FILE, a mount point is a logical drive  
associated with an I/O stream. The number of mount points for a device class is  
determined by the mount limit for that class. See mount limit.  
mount request  
A server request to mount a sequential access media volume so that data can be  
read from or written to the sequential access media.  
mount retention period  
A device class attribute that specifies the maximum number of minutes that the  
server retains a mounted sequential access media volume that is not being used  
before it dismounts the sequential access media volume.  
mount wait period  
A device class attribute that specifies the maximum number of minutes that the  
server waits for a sequential access volume mount request to be satisfied before  
canceling the request.  
Multiple Virtual Storage (MVS)  
One of the family of IBM operating systems for the System/370or System/390®  
processor, such as MVS/ESA. MVS is one of the supported server environments.  
MVS  
Multiple Virtual Storage.  
1430  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N
Named Pipes  
A communication protocol that is built into the Windows NT or OS/2 operating  
system. It can be used to establish communications between the TSM server and  
any TSM clients on the same system.  
NetBIOS  
Network Basic Input/Output System.  
network adapter  
A physical device, and its associated software, that enables a processor or controller  
to be connected to a network.  
Network Basic Input/Output System (NetBIOS)  
An operating system interface for application programs used on IBM personal  
computers that are attached to the IBM Token-Ring Network.  
Network File System (NFS)  
A protocol defined by Sun Microsystems that extends TCP/IP network file services.  
NFS permits remote node files to appear as though they are stored on a local  
workstation.  
Networking Services/DOS (NS/DOS)  
A software product that supports advanced program-to-program communications  
(APPC) in the DOS and Microsoft Windows 3.1 environments. With NS/DOS,  
communications applications on your workstation “talk to” partner applications on  
other systems that support APPC.  
NFS  
Network File System.  
node  
A unique name used to identify a workstation to the server. See also client node.  
notify operator  
A VM user ID that specifies an operator who receives messages about severe errors  
and abnormal conditions.  
O
object  
A collection of data managed as a single entity.  
offsite recovery media  
Media that is kept at a different location to ensure its safety if a disaster occurs at  
the primary location of the computer system. The media contains data necessary to  
Tivoli Storage Manager Messages  
1431  
Download from Www.Somanuals.com. All Manuals Search And Download.  
recover the TSM server and clients. The offsite recovery media manager, which is  
part of DRM, identifies recovery media to be moved offsite and back onsite, and  
tracks media status.  
offsite volume  
A removable media volume that is at a location where it cannot be mounted for use.  
open registration  
A registration process in which users can register their own workstations as client  
nodes with the server. Contrast with closed registration.  
Operating System/2® (OS/2)  
An operating system used in IBM PC AT®, PS/2, and compatible computers.  
operator privilege class  
An administrative privilege class that allows an administrator to issue commands  
that control the operation of the server. This privilege class allows disabling or  
halting the server to perform maintenance, enabling the server, canceling server  
processes, and managing tape.  
optical library  
A storage device that houses optical disk drives and optical disks, and contains a  
mechanism for moving optical disks between a storage area and optical disk drives.  
OS/2  
Operating System/2.  
OS/390®  
OS/400®  
owner  
Operating System/390.  
Operating System/400®.  
The owner of backup-archive files sent from a multiuser client node, such as AIX.  
P
page  
(1) A block of instructions, data, or both. (2) In TSM, a unit of space allocation  
within database volumes. (3) In a virtual storage system, a fixed block that has a  
virtual address and is transferred as a unit between real storage and auxiliary  
storage.  
1432  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
paging  
(1) The action of transferring instructions, data, or both, between real storage and  
external page storage. (2) Moving data between memory and a mass storage device  
as the data is needed.  
pattern-matching expression  
A string expression that uses wildcard characters to specify one or more TSM  
objects. See also wildcard character.  
physical file  
A file, stored in one or more storage pools, consisting of either a single logical file,  
or a group of logical files packaged together (an aggregate file). See also aggregate  
file and logical file.  
physical occupancy  
The occupancy of physical files in a storage pool. This is the actual space required  
for the storage of physical files, including the unused space created when logical  
files are deleted from aggregates. See also physical file, logical file, and logical  
occupancy.  
platform  
The operating system environment in which a program runs.  
policy domain  
A policy object that contains policy sets, management classes, and copy groups that  
are used by a group of client nodes. See policy set, management class, and copy  
group.  
policy privilege class  
An administrative privilege class that allows an administrator to manage policy  
objects, register client nodes, and schedule client operations (such as backup  
services) for client nodes. Administrators can be authorized with unrestricted or  
restricted policy privilege.  
policy set  
A policy object that contains a group of management class definitions that exist for  
a policy domain. At any one time there can be many policy sets within a policy  
domain but only one policy set can be active. See management class and active  
policy set.  
premigration  
For an HSM client, the process of copying files that are eligible for migration to  
TSM storage, but leaving the original file intact on the local system.  
Tivoli Storage Manager Messages  
1433  
Download from Www.Somanuals.com. All Manuals Search And Download.  
primary storage pool  
A named set of volumes that TSM uses to store backup versions of files, archive  
copies of files, and files migrated from HSM client nodes. A primary storage pool  
may be backed up to a copy storage pool. See destination and copy storage pool.  
privilege class  
A level of authority granted to an administrator of TSM . The privilege class  
determines which TSM administrative tasks the administrator can perform. For  
example, an administrator with system privilege class can perform any  
administrative task. See system privilege class, policy privilege class, storage  
privilege class, operator privilege class, andanalyst privilege class.  
profile  
A named group of configuration information that can be distributed from a  
configuration manager when a managed server subscribes. Configuration  
information can include registered administrators, policy, client schedules, client  
option sets, administrative schedules, server command macros, server definitions,  
and server group definitions. See configuration manager and managed server.  
protection status  
A device class attribute that specifies whether to update the RACF® profile to  
identify which users have access to cartridge tapes associated with this device class  
on MVS servers.  
Q
R
QIC  
Quarter-inch cartridge (a type of magnetic tape media).  
random access media  
Any volume accessed in a nonsequential manner. In TSM, volumes are accessed in  
a nonsequential manner if they reside in the DISK device class.  
randomization  
The percentage of the startup window that the server can use to randomize start  
times for different client nodes associated with a schedule.  
rebinding  
The process of associating a file with a backed-up file with a new management  
class name. For example, rebinding occurs when the management class associated  
with a file is deleted. See binding.  
1434  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
recall  
A function that allows users to access files that have been migrated from their  
workstations to TSM storage via the Tivoli Space Manager (HSM client). Contrast  
with migrate.  
reclamation  
A process of consolidating the remaining data from many sequential access volumes  
onto fewer new sequential access volumes.  
reclamation threshold  
The percentage of reclaimable space that a sequential access media volume must  
have before the server can reclaim the volume. Space becomes reclaimable when  
files are expired or are deleted. The percentage is set for a storage pool.  
recovery log  
A log of updates that are about to be written to the database. The log can be used to  
recover from system and media failures.  
recovery log buffer pool  
Used to hold new transactions records until they can be written to the recovery log.  
recovery media  
Media that contains data necessary to recover the TSM server and clients.  
reduce  
REEL  
register  
The process of freeing up enough space to allow you to delete a volume from the  
database or recovery log. Contrast with extend.  
On TSM servers that support it, a device class that is used to categorize tape  
devices that support tape reels, such as the 3420 9-track tape device.  
(1) Define a client node or administrator who can access the server. See registration.  
(2) Specify licenses that have been purchased for the server.  
registration  
The process of identifying a client node or administrator to the server.  
reply operator  
On a VM server, a VM user ID that specifies an operator who will reply to tape  
mount requests by the server.  
restore  
The process of returning a backup copy to an active storage location for use. TSM  
has processes for restoring its database, storage pools, storage pool volumes, and  
Tivoli Storage Manager Messages  
1435  
Download from Www.Somanuals.com. All Manuals Search And Download.  
users’ backed-up files. For example, users can copy a backup version of a file from  
the storage pool to the workstation. The backup version in the storage pool is not  
affected. Contrast with backup.  
retention  
The amount of time, in days, that inactive backed up or archived files are kept in  
the storage pool before they are deleted. Copy group attributes and default retention  
grace periods for the domain define retention.  
retention period  
On an MVS server, a device class attribute that specifies how long files are retained  
on sequential access media. When used, TSM passes this information to the MVS  
operating system to ensure that other tape management systems do not overwrite  
tape volumes that contain retained data.  
retrieve  
A function that allows users to copy an archive copy from the storage pool to the  
workstation. The archive copy in the storage pool is not affected. Contrast with  
archive.  
rollback  
To remove changes that were made to database files since the last commit point.  
root user  
In the AIX and UNIX environments, a user who has superuser authority. The user  
can log in and execute restricted commands, shut down the system, and edit or  
delete protected files.  
S
schedule  
A database record that describes scheduled client operations or administrative  
commands. See administrative command schedule and client schedule.  
scheduling mode  
The type of scheduling operation set for the server and client. TSM supports two  
scheduling modes for client operations: client-polling and server-prompted.  
scratch volume  
A volume that is available for TSM use. The volume is labeled, is either blank or  
contains no valid data, and is not defined to TSM.  
script  
SCSI  
See TSM command script.  
Small computer system interface.  
1436  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
selective backup  
A function that allows users to back up specific files or directories from a client  
domain. With this function, users can back up files or directories that are not  
excluded in the include-exclude list and that meet the requirement for serialization  
as defined in the backup copy group of the management class assigned to the files.  
Contrast with incremental backup.  
sequential access media  
Any volume that is accessed in a sequential manner, as opposed to a random  
manner. In TSM, volumes are accessed sequentially if they reside in a device class  
other than DISK.  
serialization  
A copy group attribute that specifies what TSM does if files are modified during  
back up or archive processing. The value of this attribute determines whether  
processing continues, is retried, or is stopped. See static, dynamic, shared static, and  
shared dynamic.  
server  
The program that provides backup, archive, space management, and administrative  
services to clients. The server program must be at the necessary level to provide all  
of these services.  
server migration  
The process of moving data from one storage pool to the next storage pool as  
controlled by the high and low migration thresholds. See high migration threshold  
and low migration threshold.  
server options file  
A file that specifies processing options for communication methods, tape handling,  
pool sizes, language, and date, time, and number formats.  
server-prompted scheduling mode  
A client/server communication technique where the server contacts the client when a  
scheduled operation needs to be done.  
server storage  
The primary and copy storage pools used by the server to store users’ files: backup  
versions, archive copies, and files migrated from Tivoli Space Manager client nodes  
(space-managed files). See primary storage pool, copy storage pool, storage pool  
volume, and volume.  
session resource usage  
The amount of wait time, CPU time, and space used or retrieved during a client  
session.  
Tivoli Storage Manager Messages  
1437  
Download from Www.Somanuals.com. All Manuals Search And Download.  
shared dynamic  
A copy group serialization value that specifies that a file must not be modified  
during a backup or archive operation. TSM attempts to retry the backup or archive  
operation a number of times; if the file is in use during each attempt, TSM will  
back up or archive the file on its last try even though the file is in use. See also  
serialization. Contrast with dynamic, shared static, and static.  
shared static  
A copy group serialization value that specifies that the file must not be modified  
during backup or archive. TSM will retry the backup or archive operation a number  
of times; if the file is in use during each attempt, TSM will not back up or archive  
the file. See also serialization. Contrast with dynamic, shared dynamic, and static.  
shell  
In the AIX and UNIX environments, a software interface between a user and the  
operating system of a computer. Shell programs interpret commands and user  
interactions on devices such as keyboards, pointing devices, and touch-sensitive  
screens and communicate them to the operating system.  
SMIT  
System Management Interface Tool.  
SNA LU6.2  
Systems Network Architecture Logical Unit 6.2.  
snapshot  
See database snapshot.  
socket  
(1) An endpoint for communication between processes or applications. (2) A pair  
consisting of TCP port and IP address, or UDP port and IP address.  
source server  
A server that can send data, in the form of virtual volumes, to another server.  
Contrast with target server.  
space-managed file  
A file that is migrated from and recalled to a client node via Tivoli Space Manager  
(HSM client).  
space management  
The process performed by Tivoli Space Manager to keep sufficient free storage  
space available on a client node by migrating files to Tivoli Storage Manager  
storage. The files are migrated based on criteria defined in management classes to  
which files are bound, and the include-exclude list. Synonymous with hierarchical  
storage management. See also migration.  
1438  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
space manager client  
Synonym for hierarchical storage management (HSM) client.  
stale copy status  
Specifies that a volume copy is not available to the database or recovery log.  
stanza  
A group of lines in a file that together have a common function or define a part of  
the system. Stanzas are usually separated by blank lines or colons, and each stanza  
has a name.  
startup window  
A time period during which a schedule must be initiated.  
static  
A copy group serialization value that specifies that the file must not be modified  
during backup or archive. If the file is modified during the attempt, TSM will not  
back up or archive the file. See also serialization. Contrast with dynamic, shared  
dynamic, and shared static.  
storage hierarchy  
A logical ordering of primary storage pools, as defined by an administrator with  
system privilege. Generally, the ordering is based on the speed and capacity of the  
devices that the storage pools use. In TSM, the storage hierarchy is defined by  
identifying the next storage pool in a storage pool definition. See storage pool.  
storage management services  
A component that allows a central system to act as a file backup, archive, and space  
management server for local area network file servers and workstations.  
storage pool  
A named set of storage volumes that TSM uses to store client data. A storage pool  
is either a primary storage pool or a copy storage pool. See primary storage pool  
and copy storage pool.  
storage pool volume  
A volume that has been assigned to a TSM storage pool. See volume, copy storage  
pool, and primary storage pool.  
storage privilege class  
An administrative privilege class that allows an administrator to control the  
allocation and use of storage resources for the server, such as monitoring the  
database, recovery log, and server storage. Administrators can be authorized with  
unrestricted or restricted storage privilege.  
stub file  
A file that replaces the original file on a client node when the file is migrated from  
the client node to TSM storage.  
Tivoli Storage Manager Messages  
1439  
Download from Www.Somanuals.com. All Manuals Search And Download.  
subscription  
The method by which a managed server requests that it receive configuration  
information associated with a particular profile on a configuration manager. See  
managed server, configuration manager, and profile.  
superuser  
See root user.  
synchronized copy status  
Specifies that the volume is the only volume copy or is synchronized with other  
volume copies in the database or recovery log. When synchronized, mirroring has  
started.  
system privilege class  
An administrative privilege class that allows an administrator to issue all server  
commands.  
Systems Application Architecture (SAA)  
Software interfaces, conventions, and protocols that provide a framework for  
designing and developing applications that are consistent across systems.  
Systems Network Architecture (SNA)  
A set of rules for data to be transmitted in a network. Application programs  
communicate with each other using a layer of SNA called advanced  
program-to-program communications (APPC).  
T
tape library  
(1) A term used to refer to a collection of tape cartridges. (2) An automated device  
that performs tape cartridge mounts and demounts without operator intervention.  
Tape Library Dataserver  
An automated tape library consisting of mechanical components, cartridge storage  
frames, IBM tape subsystems, and controlling hardware and software. The tape  
library dataserver performs tape cartridge mounts and demounts without operator  
intervention.  
tape volume prefix  
A device class attribute that is the high-level-qualifier of the file name or the data  
set name in the standard tape label.  
target server  
A server that can receive data sent from another server. Contrast with source server.  
See also virtual volumes.  
1440  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TCP/IP  
Telnet  
Transmission Control Protocol/Internet Protocol.  
In TCP/IP, the protocol that opens the connection to the system.  
Tivoli Disaster Recovery Manager (DRM)  
A product that works with TSM to assist in preparing and later using a disaster  
recovery plan for the TSM server.  
Tivoli Storage Manager (TSM)  
A client/server program that provides storage management to customers in a  
multivendor computer environment.  
Transmission Control Protocol/Internet Protocol (TCP/IP)  
A set of communication protocols that support peer-to-peer connectivity functions  
for both local and wide area networks.  
trusted communication agent  
A program that performs communication tasks on behalf of the client or server, and  
ensures the security of the communications.  
TSM  
Tivoli Storage Manager.  
TSM application program interface (API)  
A set of functions that applications running on a client platform can call to store,  
query, and retrieve objects from TSM storage.  
TSM command script  
A sequence of TSM administrative commands that are stored in the TSM database.  
The script can include substitution for command parameters and conditional logic.  
You can run the script from any interface to the server.  
U
unit name  
On an MVS server, a device class attribute that specifies a group of tape devices  
used with the MVS server. A unit name can be a generic device type, an esoteric  
unit name, or a physical device.  
UNIX System Services  
MVS/ESA services that support an environment within which operating systems,  
servers, distributed systems, and workstations share common interfaces. UNIX  
System Services supports standard application development across multivendor  
systems and is required to create and use applications that conform to the POSIX  
standard. UNIX System Services was formerly known as OpenEdition® MVS.  
Tivoli Storage Manager Messages  
1441  
Download from Www.Somanuals.com. All Manuals Search And Download.  
utilization  
The percent of assigned capacity used by the database or recovery log at a specific  
point of time.  
V
validate  
version  
The process of ensuring that the active policy set contains a default management  
class and reporting on copy group definition errors.  
The maximum number of backup copies retained for files and directories. The  
following copy group attributes define version criteria: versions data exists and  
versions data deleted.  
Virtual Machine (VM)  
One of the family of IBM operating systems for the System/390 processor,  
including VM/ESA®.  
Virtual Storage Extended (VSE)  
One of the family of IBM operating systems for the System/390 processor,  
including VSE/ESA.  
virtual volume  
A volume that appears to be a sequential media volume on a source server but that  
is actually stored as an archive file on a target server.  
VM  
Virtual Machine.  
volume  
The basic unit of storage for the TSM database, recovery log, and storage pools. A  
volume can be an LVM logical volume, a standard file system file, a tape cartridge,  
or an optical cartridge. Each volume is identified by a unique volume identifier. See  
database volume, scratch volume, and storage pool volume.  
volume history file  
A file that contains information about: volumes used for database backups and  
database dumps; volumes used for export of administrator, node, policy, or server  
data; and sequential access storage pool volumes that have been added, reused, or  
deleted. The information is a copy of the same types of volume information in the  
TSM database.  
VSE  
Virtual Storage Extended.  
1442  
Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
W
X
wildcard character  
A character or set of characters used to specify an unknown number or set of  
characters in a search string. Also called pattern-matching character.  
WORM  
A type of optical media that can only be written to and cannot be erased.  
X Windows  
A network transparent windowing system developed by MIT. It is the basis for other  
products, such as Enhanced X Windows which runs on the AIX operating system.  
Tivoli Storage Manager Messages  
1443  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program Number: 5697-DRM  
5697-TSM  
5697-DRO  
5697-TSO  
5697-DPN  
5697-DPO  
5697-DPS  
5697-DPX  
5697-SPM  
Printed in the United States of America  
on recycled paper containing 10%  
recovered post-consumer fiber.  
GC35-0382-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spine information:  
Tivoli Storage Manager Messages, Version 3 Release 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tech Craft TV Video Accessories BEL320B User Manual
Tektronix Saw TM 5006A User Manual
Toshiba Computer Drive MK2565GSX User Manual
Tricity Bendix Cooktop SIE056 User Manual
Tripp Lite Network Cables N001 005 BK User Manual
Troy Bilt Lawn Mower 429 User Manual
Troy Bilt Trimmer TB525 EC User Manual
Uniden Scanner BCT8 User Manual
Universal Remote Control Universal Remote UR4U MDVR CHD2 User Manual
Verizon Cell Phone Accessories Hotspot 890L User Manual