Thermo Serv Thermostat 9915i User Manual

i
9901  
DELUXE  
PROGRAMMABLE  
THERMOSTATS  
i
9915  
i
9920  
User's Manual  
Menu Driven Display  
Integrated Damper /  
Economizer Control  
Fresh Air  
Control  
24 VAC with Worry-Free  
Memory Storage  
English and Spanish Menus  
110-1069  
Two Year Warranty  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Changing the Time of Day  
Turning on Heating and Cooling Cycles  
MONDAY  
3:29 PM  
MONDAY  
3:29 PM  
From the main screen press MENU.  
From the main screen press MENU.  
COOL  
COOL  
FAN AUTO  
FAN AUTO  
78.1  
78.1  
SET AT 78  
SET AT 78  
MENU  
HOLD TEMP  
MENU  
HOLD TEMP  
MENU  
MENU  
Use the UP or DOWN arrows to highlight DAY/TIME.  
Press SELECT.  
PROGRAM  
DAY / TIME  
Use the UP or DOWN arrows to highlight HEAT/COOL.  
Press SELECT.  
HEAT / COOL  
FAN  
FRESH AIR  
DAY / TIME  
HOME  
USER SETTINGS  
INSTALLER SETTINGS  
HOME  
HEAT / COOL SETTINGS  
SELECT  
SELECT  
SET DAY & TIME  
OFF  
Use the UP or DOWN arrows to highlight HEAT, COOL  
or AUTO. Press SELECT. The SELECT button will turn  
on the desired cycle. You do not have to turn off HEAT to  
turn on COOL. When HEAT or COOL or AUTO is turned  
on, all others are automatically shut off. After pressing  
the SELECT button, the main screen will  
FRIDAY  
12 PM  
06  
DAY  
HOUR  
HEAT  
COOL  
AUTO  
Use the UP or DOWN arrow to highlight DAY, HOUR  
or MINUTES. Press SET.  
MINUTES  
HEAT / COOL SETTINGS  
HEAT  
SET DAY & TIME  
FRIDAY  
MAIN MENU  
SELECT  
FINISHED  
SET  
automatically appear.  
DAY  
COOL  
12 PM  
31  
HOUR  
MINUTES  
Use the UP or DOWN arrow to scroll through  
the days of the week, hours or minutes.  
Press SET to select desired value.  
NOTE: Emergency heat is used only on the 9920i model.  
NOTE: AUTO appears only if Auto Changeover is turned on in the Installer Settings.  
AUTO  
EMERGENCY HEAT  
MAIN MENU  
Press FINISHED when complete.  
FINISHED  
SET  
SELECT  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
What do the LED’s below the display mean?  
Fan Cycles  
MONDAY  
3:29 PM  
The LED’s indicate when the HVAC system is activated. With a call for heating or cooling, the HEAT or COOL LED will be illuminated.  
The AUX LED indicates the second stage of heating or cooling.  
COOL  
From the main screen press MENU.  
FAN AUTO  
78.1  
SET AT 78  
HOLD TEMP  
MENU  
MENU  
Use the UP or DOWN buttons until FAN is highlighted. Press SELECT.  
The CHECK LED is used only on the 9920i. It indicates the heat pump should be serviced by a qualified technician.  
The EMER LED indicates that the emergency heat is turned on.  
HEAT / COOL  
FRESH AIR  
DAY / TIME  
FAN  
HOME  
SELECT  
Use the UP or DOWN buttons to highlight FAN settings.  
Press SELECT.  
FAN MENU  
FAN SETTINGS  
Three choices are available:  
ON will turn the fan on continuously.  
AUTO will turn the fan on only  
when there is a call for heating  
or cooling.  
INTERMITTENT will turn the fan  
on for a set period of time for a  
given interval. Highlight the choice  
you desire and press SELECT.  
FAN PROGRAM  
FAN SETTINGS  
ON  
AUTO  
MAIN MENU  
SELECT  
INTERMITTENT  
FAN MENU  
SELECT  
Intermittent Fan  
INTERMITTENT will turn the fan on for a set period of time for a  
given interval.  
INTERMITTENT FAN  
ON  
TIMEꢀ  
5MIN  
The thermostat will cycle the fan on for the set ON cycle. The fan will remain off for the set OFF cycle.  
OFF TIMEꢀ  
20MIN  
If the HVAC system runs for a longer period than the ON cycle, the OFF cycle will start counting over  
again when the system shuts off.  
FAN MENU  
SELECT  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Temporary Temperature Adjustments  
Timed Temperature Adjustments  
MONDAY  
3:29 PM  
MONDAY  
3:29 PM  
COOL  
COOL  
FAN AUTO  
Press the HOLD TEMP button. The following screen appears.  
78.1  
From the main screen, press the UP or DOWN button. The screen  
will change to the following.  
SET AT 78  
FAN AUTO  
78.1  
SET AT 78  
HOLD TEMP  
MENU  
HOLD SETTINGS  
PERMANENT HOLD  
HOLD TEMP  
MENU  
Press the DOWN button to highlight TEMPORARY HOLD. Press SELECT.  
SET TEMPERATURE AT  
TEMPORARY HOLD  
VACATION HOLD  
HOME  
Use the UP or DOWN button to adjust to the desired  
temperature. This is a temporary 3-hour hold or until  
the next programmed event, whichever is shorter.  
For a longer duration see page 9.  
F
70 ˚  
SELECT  
TEMPORARILY AT  
The temperature should be highlighted.  
UNTIL 6:30 PM  
F
Press the UP or DOWN button to adjust  
70 ˚  
the temperature. Press SET TEMP.  
HOME  
SET TEMP  
UNTIL 3:50 PM  
After pressing the SET  
TEMP button or after 5  
seconds the screen will  
indicate the new setpoint  
and its duration. To return  
to the normal operating  
program mode, press  
RESUME PROGRAM.  
SET AT 70°F UNTIL 6:30 PM  
COOL  
HOME  
SET TEMP  
TEMPORARILY AT  
F
FAN AUTO  
F
70 ˚  
The time should be highlighted. Press the UP or  
DOWN button to adjust the time. Press SET TIME.  
70.5˚  
UNTIL 3:50 PM  
SET AT 70°F UNTIL 8:29 PM  
RESUME  
HOME  
SET TIME  
PROGRAM  
COOL  
FAN AUTO  
MENU  
F
°
The main screen will now indicate a TEMPORARY HOLD until the  
desired time. Press RESUME PROGRAM to return to the program  
operating mode.  
77.0  
RESUME  
PROGRAM  
MENU  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Permanent Hold  
Vacation Hold  
MONDAY  
3:29 PM  
MONDAY  
3:29 PM  
COOL  
COOL  
From the main screen press the HOLD TEMP button. The following screen appears.  
From the main screen press the HOLD TEMP button. The following screen appears.  
FAN AUTO  
FAN AUTO  
78.1  
SET AT 78  
78.1  
SET AT 78  
HOLD TEMP  
MENU  
HOLD SETTINGS  
HOLD TEMP  
MENU  
HOLD SETTINGS  
The PERMANENT HOLD feature should be highlighted. If it is not, use  
the UP or DOWN arrow to highlight it. Press SELECT.  
PERMANENT HOLD  
Use the UP or DOWN arrow to highlight the VACATION HOLD feature.  
PERMANENT HOLD  
TEMPORARY HOLD  
VACATION HOLD  
HOME  
Press SELECT.  
TEMPORARY HOLD  
VACATION HOLD  
HOME  
PERMANENTLY AT  
SELECT  
SELECT  
VACATION SETTING  
F
F
Use the UP or DOWN arrow to set the temperature to  
the desired level. Press SET TEMP.  
70 ˚  
The temperature should be highlighted. Use the UP  
or DOWN arrow change to the desired temperature.  
Press SET TEMP.  
70 ˚  
HOLD MENU  
SET TEMP  
PERMANENTLY SET AT 71.0°F  
FOR 7 DAYS  
F
COOL The main screen will now  
HOLD MENU  
SET TEMP  
FAN AUTO  
indicate a PERMANENT  
HOLD. Press RESUME  
PROGRAM to return to the  
program operating mode.  
VACATION SETTING  
F
70.0˚  
RESUME  
The number of days should be highlighted. Use  
the UP or DOWN arrow to set the length of your  
vacation. Press SET DAY.  
PROGRAM  
MENU  
70 ˚  
FOR 7 DAYS  
Returning to Program Mode  
BACK  
SET DAY  
SET AT 70°F FOR 7 DAYS  
PERMANENTLY SET AT 71.0°F  
COOL  
F
°
F
COOL  
FAN AUTO  
77.0  
FAN AUTO  
Simply press the RESUME PROGRAM button. This works from all HOLD screens.  
The main screen will now indicate the VACATION settings.  
Press RESUME PROGRAM to cancel and return to the  
program operating mode.  
70.0˚  
RESUME  
RESUME  
PROGRAM  
PROGRAM  
MENU  
MENU  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Programming  
Programming (Con’t.)  
MONDAY  
3:29 PM  
MONDAY PROGRAM  
COOL  
HEAT  
COOL  
FAN AUTO  
OCC  
UNOCC06:00Pꢀ  
COPY  
08:30Aꢀ  
72.078.0  
62.082.0  
From the main screen press the MENU button.  
The time for the first event should be highlighted. Use the UP or DOWN key to change the time.  
Press SET TIME.  
78.1  
SET AT 78  
HOLD TEMP  
MENU  
MENU  
BACK  
SET TIME  
MONDAY PROGRAM  
PROGRAM  
Use the UP or DOWN button to highlight PROGRAM. Press SELECT.  
HEAT  
COOL  
HEAT / COOL  
FRESH AIR  
DAY / TIME  
OCCꢀ  
08:30Aꢀ  
72.078.0  
The heating setpoint for the first event will be highlighted. Use the UP or  
DOWN key to change the desired temperature. Press SET HEAT.  
UNOCC06:00Pꢀ  
62.082.0  
COPY  
HOME  
SELECT  
You can select a variety of programming. Make your  
selection and press SELECT. MON-SUN allows every  
day to be set the same. MON-FRI allows for weekday  
programming while SAT-SUN will adjust weekends differ-  
ently. You also can select each day of the week individu-  
ally. NOTE: Even if you select MON-SUN, you still can  
go back and change individual days to suit your lifestyle.  
SELECT PROGRAM DAYS  
BACK  
SET HEAT  
MON TO SUN  
MON TO FRI  
SAT TO SUN  
MONDAY  
MONDAY PROGRAM  
HEAT  
72.078.0  
62.082.0  
COOL  
The cooling setpoint for the first event will  
be highlighted. Use the UP or DOWN key  
to change the desired temperature. Press  
SET COOL.  
OCCꢀ  
08:30Aꢀ  
UNOCC06:00Pꢀ  
COPY  
MAIN MENU  
SELECT  
MONDAY PROGRAM  
Use the UP or DOWN button to  
HEAT  
COOL  
select the event to program. The  
thermostat can be selected for 2,  
4, or 6 events per day. See USER  
SETTINGS for EVENTS PER  
BACK  
SET COOL  
OCCꢀ  
08:30Aꢀ  
72.078.0  
MONDAY PROGRAM  
UNOCC06:00Pꢀ  
62.082.0  
COPY  
HEAT  
COOL  
The second event will now be highlighted.  
Use the UP or DOWN key to change events if  
desired.  
OCCꢀ  
UNOCC06:00Pꢀ  
COPY  
08:30Aꢀ  
72.078.0  
62.082.0  
DAY selection. After selecting the  
event to program, press SELECT.  
MAIN MENU  
SELECT  
BACK  
SELECT  
Please go to the next page for a continued discussion on programming.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Copy Command  
Events  
MONDAY PROGRAM  
An event is a programming period. This could be the period in the morning when the facility is occupied. It could be the period when  
no one is at work. It could be the evening.  
HEAT  
COOL  
OCC  
08:30Aꢀ  
72.078.0  
In the program screen, press the DOWN button until COPY is highlighted.  
Press SELECT.  
UNOCC06:00Pꢀ  
62.082.0  
The time for an event is selected based on when you want the event to occur. For example, if people start to arrive at the facility at  
6:30 AM, set the first event for 6:30 AM. The thermostat will automatically make sure the environment is at the desired temperature  
selected for that event by the time you desired.  
COPY  
NOTE: Copy command will appear only if programming an individual day.  
MAIN MENU  
SELECT  
This thermostat can be selected for 2, 4, or 6 events.  
Energy Saving Programs  
COPY MONDAY TO  
The thermostat is set with the US EPA ENERGYSTAR® recommended times and temperatures for optimal energy savings. You can  
change these to suit your lifestyle.  
Use the UP or DOWN button to highlight the  
day to copy to. Press YES / NO. A YES will  
appear next to the day. Do this for each day to  
which that program is to be copied. Press  
FINISHED when complete.  
TUESDAYꢀ  
WEDNESDAY  
THURSDAY  
FRIDAYꢀ  
YES  
The best rule is to examine your schedule and set the times and temperatures that best fit. This thermostat is so versatile, you can  
easily temporarily change temperatures or programs at a whim.  
YES  
FINISHED  
YES / NO  
CONTINUE  
PROGRAMMING?  
After pressing FINISHED, you can choose to pro-  
gram other days or exit. YES will take you back to  
the Select Program Days screen. NO will exit you  
to the main screen.  
NOꢀꢀ  
YES  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Setting the Economizer / Damper Program  
User Settings  
MONDAY  
3:29 PM  
MAIN MENU  
The thermostat can be set to open or close a damper or economizer at different times during the day. To  
program this setting, select FRESH AIR from the main menu and press SELECT.  
COOL  
HEAT / COOL  
DAY / TIME  
FAN  
The USER SETTINGS can change the way information is displayed on the thermostat and help  
to optimize comfort. It’s one way to truly personalize your new thermostat.  
FAN AUTO  
78.1  
SET AT 78  
FRESH AIR  
FRESH AIR MENU  
HOLD TEMP  
MENU  
HOME  
SELECT  
Select PROGRAM. Press SELECT.  
PROGRAM  
PURGE CYCLE  
MENU  
DAY / TIME  
To get to the USER SETTINGS, press the MENU button from the main screen.  
FAN  
FRESH AIR  
MAIN MENU  
SELECT  
FRESH AIR PROGRAM  
MON TO SUN  
WEEKDAY  
WEEKEND  
MONDAY  
Programming is just like the temperature program. The  
time of the events is determined from the setting in the  
TEMPERATURE PROGRAM MENU.  
USER SETTINGS are below the FAN settings. Use the DOWN button to scroll below the  
screen. Press SELECT.  
USER SETTINGS  
HOME  
SELECT  
FRESH AIR MENU  
SELECT  
WEEKDAY F / A PROGRAM  
Using the UP or DOWN  
Choose the setting you would like to change. When the SETTING is highlighted, press SELECT. There are 13 USER  
SETTINGS in all as listed below. For detailed information on each user setting, please go to the next page.  
arrow, select OPEN or  
ꢀꢀ  
DAMPER  
OCCꢀ  
08:00AMOPEN  
CLOSED for each event.  
UNOCCꢀ  
10:00PMCLOSED  
USER SETTINGS MENU  
OR Cꢀ  
USER SETTINGS MENU  
USER SETTINGS MENU  
COOLING LIMITꢀ  
USER SETTINGS MENU  
HEATING LIMITꢀ  
BACK  
SELECT  
Setting the Purge Cycle  
1ST STAGE DIFFꢀ  
2ND STAGE DIFFꢀ  
2ND STAGE DELAYꢀ  
COOLING LIMITꢀ  
1˚F  
2˚F  
F
˚F  
12  
68˚F  
78˚F  
78˚F  
ENG  
L & R  
OFF  
12 OR 24hrꢀ  
HEATING LIMITꢀ  
LANGUAGEꢀ  
LANGUAGEꢀ  
20  
SHOW SET TEMPꢀ  
EVENTS / DAYꢀ  
YES  
4
ENG  
L & R  
SENSOR SELECTꢀ  
SECURITYꢀ  
PURGE CYCLE  
During periods when the facility may be unoccupied, the thermostat can open the damper or economizer  
to bring in fresh air for short periods of time. To set, simply select PURGE CYCLE from the FRESH AIR  
MENU and press SELECT.  
45˚F  
SENSOR SELECTꢀ  
OPEN TIMEꢀ  
5MIN  
SELECT  
MAIN MENU  
SELECT  
MAIN MENU  
SELECT  
MAIN MENU  
SELECT  
CLOSED TIMEꢀ  
2HR  
MAIN MENU  
Using the UP and DOWN buttons, change the desired open time and close time for the damper.  
To disable this function, set the OPEN TIME to 0. The word OFF will appear.  
NOTE: This function will operate only when the damper is closed during an event.  
FRESH AIR MENU  
SELECT  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
Detailed Information on the USER SETTINGS  
More Detailed Information on the USER SETTINGS  
To select a USER SETTING, use the UP or DOWN button to highlight the desired value. Press SELECT to select desired value.  
DIFFERENTIAL SETTINGS  
DIFFERENTIAL SETTING  
The temperature differential is your comfort level. The differential is the difference from setpoint  
before your heating or cooling system will turn on. The 9915i and 9920i models also have 2nd  
stage differential. If the temperature falls below (or above for cooling) the setpoint by the 1st stage  
differential plus the 2nd stage, the auxiliary heating (or cooling) system will turn on.  
1ST DIFFꢀꢀ  
1˚F  
TEMPERATURE  
2ND DIFFꢀꢀ  
2ND DELAYꢀꢀ  
2˚F  
TEMPERATURE: Fahrenheit or Celsius  
Temperature will be displayed in F or C.  
˚F  
20 MIN  
˚C  
USER MENU  
SELECT  
The 2nd stage delay is a timed delay before the second stage will turn on if the setpoint has not  
been achieved within that time frame.  
USER MENU  
CLOCK  
SELECT  
CLOCK SETTINGS  
Displays time in standard 12-hour format or military format.  
12 HOUR  
24 HOUR  
HEATING and COOLING LIMITS  
SET COOLING LIMIT  
SET HEATING LIMIT  
To prevent individuals from adjusting the thermostat too hot or too  
cold, you can limit the maximum setting for the heating and cooling  
modes. This will help you save on energy costs.  
LOWEST COOLINGꢀ  
SETTING ALLOWED  
45 °F  
HIGHEST HEATINGꢀ  
SETTING ALLOWED  
90 °F  
USER MENU  
SELECT  
DISPLAY SET POINT  
TEMPERATURE ?  
USER MENU  
SELECT  
USER MENU  
SELECT  
SETPOINT TEMPERATURE  
Each event has a setpoint temperature. Choose whether to display this value or not.  
NO  
YES  
USER MENU  
SELECT  
LANGUAGE SETTING  
This screen allows you to choose the displayed language; English or Spanish.  
SELECT A LANGUAGE  
ENGLISH  
SELECT EVENTS / DAY  
EVENTS / DAY  
4
ESPANOL  
NUMBER OF EVENTS PER DAY  
Select events per day. Choose from 2, 4, or 6 events per day.  
˜
USER MENU  
SELECT  
0
6
12  
18  
SELECT  
24  
USER MENU  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
INSTALLER Settings  
More Detailed Information on the USER SETTINGS  
The INSTALLER SETTINGS are set during the initial installation. They tell the thermostat how to function with your heating or  
cooling equipment. The following is a brief overview and discussion of these settings.  
SENSOR SETTINGS  
SENSOR SETTINGS  
This screen will appear when a remote indoor sensor (9020i) is connected to the thermostat.  
USE LOCAL SENSOR  
AVG. LOCAL / REMOTE  
USE REMOTE SENSOR  
USE LOCAL SENSOR will disable the remote sensor and only sense from the thermostat.  
INSTALLER SETTINGS  
SYSTEM SETUPGAS  
INSTALLER SETTINGS  
INSTALLER SETTINGS  
CONTACT INFO  
INSTALLER SETTINGS  
SHORT CYCLEꢀ  
AVG. LOCAL/REMOTE will take a temperature reading from both the thermostat and the remote  
sensor and average the two for even temperature control. USE REMOTE SENSOR will disable  
the sensor in the thermostat and only control from the remote location.  
OFF  
AUTOCHANGEOVERꢀ  
OFF  
EERꢀꢀ  
ON  
RESIDUAL COOLꢀ  
LOW BALANCEꢀ  
HIGH BALANCEꢀ  
60  
SERVICE INT  
REMINDERꢀ  
USER MENU  
SELECT  
DEADBANDꢀꢀ  
3˚F  
45˚F  
95˚F  
RUN  
SECURITYꢀꢀ  
OFF  
TEMP OFFSETꢀ  
3.0˚F  
SECURITY SETTINGS  
MAIN MENU  
MAIN MENU  
SELECT  
MAIN MENU  
SELECT  
SELECT  
MAIN MENU  
SELECT  
SECURITY  
In order to prevent tampering with the program and desired settings, two levels of security are avail-  
able.The first will allow only temporary changes to the temperature. It protects all other  
programmed setpoints. The second will restrict changes to EVERYTHING, including temporary  
changes to the temperature.  
CHANGE TEMP. ONLY  
PREVENT ALL CHANGES  
SYSTEM SETUP  
USER MENU  
SELECT  
FURNACE  
SYSTEM SETUP  
The 9901i has a furnace or heat pump system selection.  
HEAT PUMP  
SECURITY CODE  
ENTER SECURITY CODE  
FOR TEMPERATURE  
In this screen you enter a four-digit code. Use the UP or DOWN button to change the first value,  
press SELECT. The second digit will be highlighted. Repeat for all four values. And don’t forget your  
code. If you do, you will have to reset the entire thermostat and that will erase all the schedules  
you’ve programmed into the unit.  
INSTALL MENU  
SELECT  
0
0
0
0
1ST STAGE HEATING  
GAS / OIL  
USER MENU  
SELECT  
1st STAGE HEATING  
The 9915i can have a gas/oil or electric first stage heating.  
Choose the energy source for 1st stage heating.  
ELECTRIC  
Changing USER Settings  
About the only features you may need to change are the temperature differentials (if you desire additional comfort), and the security  
settings. All the other settings probably will not need to be changed.  
INSTALL MENU  
SELECT  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
INSTALLER settings (continued)  
INSTALLER settings (continued)  
AUXILIARY HEAT  
ENERGY EFFICIENT  
RECOVERY  
AUXILIARY HEAT  
ENERGY EFFICIENT RECOVERY  
When turned on, the thermostat will look up to two hours before the next event and anticipate when  
to turn on to reach the desired temperature.  
STANDARD - COMP. =ON  
ADD ON - COMP. =OFF  
DISABLE  
ENABLE  
The 9920i can be set to use your 2H/2C heat pump internal auxiliary heating or to use an exter-  
nal add-on source. The add-on feature will be used most often when a single stage heat pump  
uses a gas or electric furnace as its second stage of heating.  
INSTALL MENU  
SELECT  
INSTALL MENU  
SELECT  
RESIDUAL COOL  
AUTOCHANGE DEADBAND  
DEADBAND SETPOINT  
RESIDUAL COOL  
Deadband is used with the AUTO CHANGEOVER feature. The deadband is the temperature  
difference from the setpoint temperature during which the heating or cooling will not be turned on.  
This is adjustable from 2-8°F (1.0-4°C).  
SECONDS DELAY  
60  
3 ˚F  
In order to get greater efficiency from the cooling system, the fan can be programmed to run for  
0 (OFF), 30, 60, 90, or 120 seconds after the air conditioner has shut off.  
INSTALL MENU  
SELECT  
INSTALL MENU  
SELECT  
ENTER SECURITY CODE  
FOR INSTALLER  
SETTINGS  
BALANCE POINTS  
LOW BALANCEꢀ  
BALANCE POINTS  
This screen will appear only when the optional outdoor sensor 9025i is connected to the  
thermostat. When this sensor is used with the 9920i, you can set the lower temperature (below  
which the heat pump will not run) and upper temperature (above which the 2nd stage heat will not  
run). This promotes efficient operation of the heating system.  
SECURITY CODE  
Enter a code to prevent changes to the INSTALLER settings.  
45 ˚F  
HIGH BALANCEꢀ  
95 ˚F  
0
0
0
0
INSTALL MENU  
SELECT  
INSTALL MENU  
SELECT  
CONTACT INFORMATION  
AUTO CHANGEOVER  
AUTO CHANGEOVER  
AIR EXPERTS  
1-555-555-1212  
CONTACT INFORMATION  
This allows the servicing HVAC contractor to put their name and phone number into the thermostat  
to remind you when service may be required.  
DISABLEꢀ  
When turned on, the thermostat will switch automatically between heating and cooling to maintain  
the optimal temperature in your home.  
ENABLE  
BACK  
EDIT  
INSTALL MENU  
SELECT  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
SERVICE MONITOR MENU  
SERVICE MONITOR MENU  
Changing INSTALLER Settings  
The INSTALLER SETTINGS are selected based on the type of equipment you have in your facility. This feature should be set only by  
a certified HVAC technician. Changing these settings could result in higher energy costs and may even damage the equipment. You  
should only change the FILTER MONITOR length should you get a new type of filter.  
Two menus are available for the 9920i, the Service Monitor and the Filter Monitor. Three menus are  
available for the 9901i and the 9915i, the Cool Monitor, the Heat Monitor and the Filter Monitor. All  
can be set based on the HVAC system run time or the calendar. See Reminder Interval.  
All selections can be set from OFF to 360 days in 30 day increments or OFF to 980 in 20 hour increments.  
COOL MONITOR 980  
HEAT MONITOR 980  
FILTER MONITOR 980  
INSTALL MENU  
SELECT  
REMINDER INTERVAL  
REMINDER PERIOD  
Energy Efficient Recovery™ (EER™)  
The Reminder Interval can be set for either HVAC system run time or based on the calendar.  
If Run Time is chosen, the service reminder will be set in hours. After the HVAC system has been  
operating for the selected number of hours, a Service Reminder will be displayed informing you that  
service is suggested for your system.  
Energy Efficient Recovery™ is an energy saving feature. During a set back period (or set up in cooling), it allows the thermostat to  
look up to two hours ahead to determine when to turn on the heating (cooling) system. During this time period, the second stage is  
locked out to allow the first (and most efficient stage) to bring your facility to the desired temperature.  
RUN TIME  
CALENDAR TIME  
If Calendar Time is chosen, the service reminders will be set in days. After the selected number of  
days has passed, a Service Reminder will be displayed informing you that service is suggested for  
your system.  
INSTALL MENU  
SELECT  
Indoor Sensor  
The remote indoor sensor (part #9020i) can be used to improve the comfort of your home. When used in conjunction with the local  
sensor on the thermostat, the two sensors average the sensed temperature and control to that average temperature.  
TEMPERATURE OFFSET  
TEMPERATURE OFFSET  
You also can use the remote sensor in a stand-alone situation when you want to control the temperature in a remote area but have the  
thermostat in a secure location.  
The last unique feature is the OFFSET or calibration feature. This allows the installer to recalibrate  
the thermostat if the displayed room temperature is not the actual room temperature. The OFFSET  
feature also allows you to display a temperature that is different from the actual room temperature.  
+3.0 ˚F  
Outdoor Sensor  
INSTALL MENU  
SELECT  
The remote outdoor sensor (part #9025i) can be used to aid in the comfort of your facility or simply as a sensing device to inquire  
about outdoor conditions. In most applications, the thermostat will have a display of the temperature sensed by the remote outdoor  
sensor. With a heat pump system, the remote outdoor sensor can help determine when to turn on the second stage of heating for opti-  
mal comfort. The remote outdoor sensor should be installed on the northern wall of the facility, away from direct sunlight or other heat  
sources that may affect its sensitivity.  
SHORT CYCLE PROTECTION  
SHORT CYCLE  
PROTECTION  
You can change or remove the timed delay that protects the compressor in an air conditioner or  
heat pump system. Short Cycle Protection should be turned off ONLY if the HVAC system has other  
protective circuits that guarantee a compressor off time. This feature is adjustable from OFF to 5  
minutes in 1-minute increments.  
4
MINUTES  
INSTALL MENU  
SELECT  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
TWOYEAR LIMITED WARRANTY  
Additional Information  
The manufacturer warrants to the original contractor installer or to the original consumer user, each new  
Robertshaw thermostat to be free from defects in materials and workmanship under normal use and serv-  
ice for a period of two (2) years from the date of purchase.  
call at 800-445-8299.  
This warranty does not cover batteries (if so equipped), damage caused by batteries, damage resulting  
from improper installation, alteration, misuse or abuse of the thermostat occurring after the date of pur-  
chase.  
The manufacturer agrees to repair or replace at its option any thermostat under warranty provided it is  
returned within the warranty period, postage prepaid, with proof of the date of purchase. Cost of thermo-  
stat removal or reinstallation is not the responsibility of the manufacturer.  
Repair or replacement as provided under this warranty is the exclusive remedy of the consumer.This war-  
ranty and our liability does not apply to merchandise that has been damaged caused by misuse, neglect,  
mishandling, alterations, improper installation, or use in a way other than in accordance with the recom-  
mendations and instructions of the manufacturer. Except to the extent prohibited by applicable law, any  
implied warranty of merchantability or fitness for a particular purpose on this product is limited to the dura-  
tion of this warranty.  
Power Outage Protection  
The thermostat automatically retains the time of day for approximately two hours in the event of a power outage. All other programmed  
parameters are stored permanently in memory. So, if the power is out for more than two hours, simply reset the clock. See page 4.  
Resetting to Factory Conditions  
To reset the thermostat to factory conditions, press the UP button and the LEFT button at the same time. Hold for 8 seconds. The time  
of day will display 12:00 indicating a reset has occurred.  
NOTE: This will erase all programming and return the thermostat to the factory conditions including the installer settings. Use this  
only as a last resort.  
Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limi-  
tations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state to  
state.  
Instructions for return:  
Pack the thermostat carefully in a well-padded carton. Be sure to include a note describing, in detail, what  
is wrong with the product. Return, postage prepaid, to: Climate Controls Americas 515 South  
Promenade Ave., Corona, CA 91719, Attn: Warranty Department  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
Climate Controls Americas  
515 Promenade Avenue  
Corona CA 92879-1736  
United States of America  
Made in Mexico  
Patents Pending  
110-1069  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teac Stereo System PD D2610 User Manual
Tektronix Refrigerator TM 503 User Manual
Toshiba CRT Television 13A22 User Manual
Triarch Indoor Furnishings 31063 User Manual
Tricity Bendix Oven TBD913 User Manual
Tripp Lite Surge Protector 200609062 User Manual
Vector Stereo Amplifier DA 250DH CU User Manual
Venturer Flat Panel Television PLV16198 User Manual
Vermont Casting Gas Grill VCS5027 User Manual
Vulcan Hart Electric Steamer C24EA3 208 240V BASIC User Manual