TABULAR DATA SHEET
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: THJD18* THRU 60
13 SEER – R-410A, 1 PHASE
Physical and Electrical Data
THJD18
S41S3
THJD24
S41S4
THJD30
S41S4
THJD36
S41S4
THJD42
S41S4
THJD48
S41S4
THJD60
S41S4
MODEL
Unit Supply Voltage
208-230V, 1 60Hz
Normal Voltage Range 1
Minimum Circuit Ampacity
Max. Overcurrent Device Amps 2
187 to 252
19.7
11.9
20
11.2
15
14.1
20
20.9
35
25.6
45
34.9
60
30
Min. Overcurrent Device Amps 3
Compressor Type
15
Scroll
9.0
15
Recip
8.3
15
Recip
10.6
54.0
Yes
No
20
Recip
14.7
74.0
Yes
No
25
Recip
15.7
88.0
Yes
No
30
Recip
19.4
88.0
Yes
No
35
Scroll
26.9
135.0
No
Rated Load
Compressor
Amps
Locked Rotor
48.0
No
43.0
Yes
No
Crankcase Heater
Factory External Discharge Muffler
Factory External Check Valve
Yes
No
Yes
No
No
No
No
No
No
HS Kit Required with TXV 4
No
Yes
0.80
24
Yes
0.80
24
Yes
1.3
Yes
1.3
Yes*
1.3
No
Fan Motor Amps
Fan Diameter Inches
Rated HP
Rated Load
0.70
24
1.3
24
24
24
24
1/10
825
2000
15.7
1
1/8
1/8
1/4
1/4
1/4
1/4
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Rows Deep
1075
2900
18.3
1
1075
3000
21.0
1
850
3800
23.6
1
850
3800
23.6
1
850
3600
23.6
2
850
3600
23.6
2
Coil
Fin / Inches
22
22
22
22
22
18
18
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/4
3/4
3/4
3/4
7/8
7/8
7/8
Unit Charge (Lbs. - Oz.) 5
Charge Per Foot, Oz.
Operating Weight Lbs.
6 - 6
0.62
172
9 - 6
0.62
194
9 - 0
0.62
206
10 - 0
0.62
218
9 - 10
0.67
218
14 - 12
0.67
285
13 - 13
0.67
284
* These models are shipped with a Hard Start Kit installed at the factory.
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
C
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
Unit
Model
A1
28
32
36
40
40
40
40
B
C
Liquid
Vapor
34
34
34
34
34
34
34
34
34
34
34
34
34
34
18
24
30
36
42
48
60
A
3/4”
3/8”
7/8”
B
1. Including Fan Guard.
Thermo Products, LLC
MAC-220
ECN 5287-MA 121005