Installation Instructions
and
Owner's Manual
for
Thermador
Outdoor Cooktop
Model SB2B
Installer: Please leave these instructions with the unit for the owner.
Owner: Please retain these instructions for future reference.
WARNING:If the information in this manual is not followed exactly,a fire or
L explosion may result causing property damage, personal injury or death.
!
AVERTISSEMENT: Si l’information dans ce manuel n’est pas suivie exactement,
une incendie ou une explosion peut résulter, entrainant des dégats matériels, des
blessures ou la mort.
!
L
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
SECTION 1: Safety Information ............................................................. 2-4
SECTION 2: Gas Requirements................................................................... 5
Natural Gas Requirements .......................................................................... 5
Propane Gas Requirements ......................................................................... 5
Gas Consumption .......................................................................................... 5
SECTION 3: Site Preparation...................................................................... 6
Built-In Installations ....................................................................................... 6
Cabinet Preparation ...................................................................................... 6
SECTION 4: Electrical Cautions .................................................................. 7
Electrical Requirements................................................................................ 7
Grounding Instructions................................................................................. 7
SECTION 5: Unpacking, Moving and Placing the Unit ....................8 - 10
Locating your Char Glo® Barbecue ........................................................... 8
Natural Gas Hook-up ................................................................................... 8
Natural Gas to Liquid Propane Conversion ....................................8 - 10
Liquid Propane Hook-up ............................................................................ 10
SECTION 6:Test andAdjustment........................................................ 11,12
Checking for Leaks ...................................................................................... 11
Installer Checklist......................................................................................... 12
Lighting Instructions .................................................................................... 12
Burner Air Adjustment................................................................................ 12
SECTION 7: UsingYour Outdoor Cooktop ........................................... 13
SECTION 8: Care and Cleaning................................................................. 14
SECTION 9: Service ..................................................................................... 15
SECTION 10:Warranty............................................................................... 16
1
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1: SAFETY INFORMATION
FOR YOUR SAFETY
AVERTISSEMENT
S’il y a une odeur de gaz:
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
1. Coupez l’admission de gaz de l’appariel.
2. Ènteindre toute flamme nue.
3. If odor continues,immediately call your gas
supplier or your fire department.
3. Si l’odeur peraiste,appeler immediatement
votre compagnie de gaz ou votre
departement des incendies.
FOR YOUR SAFETY
AVERTISSEMENT
1. Ne pas entreposer ni utiliser de l‘essence
ni d’autres vapeurs ou liquides
inflammables dans le voisinage de l’appareil,
ni de tout autre appareil.
1. Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
2. An LP cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
2. Une bouteille de propane qui n’est pas
raccordée en vue de son utilisation,ne doit
pas etre entreposée dans le voisinage de
cet appareil ou de tout autre appareil.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
TESTED IN ACCORDANCE WITH ANSI Z21.58 – 1995, ANSI Z21.58a – 1998 STANDARD FOR
OUTDOOR COOKING GAS APPLIANCES, AND CAN/CGA 1.6 – M95, CGA 1.6a – M98,
STANDARD FOR OUTDOOR COOKING GAS APPLIANCES.
This unit is for outdoor use only in a well-ventilated area. Not to be
used in a building, garage or any other enclosed area.
Check your local building codes for the proper method of installation. In the absence of local codes this
unit should be installed in accordance with the National Fuel Gas Code No. Z223.1 Current Issue and
National Electrical Code ANSI/NFPA No. 70 Current Issue or the CAN/CGA – B149.1 Natural Gas
Installation Code or CAN/CGA - B149.2 Propane Installation Code and C22.1 Canadian Electrical Code,
Part 1.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1: SAFETY PRACTICESTO AVOID PERSONAL INJURY
WARNINGS FOR SAFE GAS INSTALLATIONS
IMPORTANT INFORMATION
GENERAL SAFETY PRECAUTIONS
This outdoor gas cooking appliance is not intended to
be installed in or on recreational vehicles and/or boats.
Readthismanualcarefullybeforeusingthecooktop
to reduce the risk of fire, electric shock, or injury to
persons.
Always inspect the natural gas or LP gas hose assembly
before each use of the appliance. If there is evidence of
excessive abrasion or wear, or if the hose is cut, it must
be replaced prior to the appliance being put into
operation. Replacement hose assemblies can be
purchasedatbarbecuesupplystores,ororderedthrough
Thermador®. If purchased at a retail outlet, the hose
assembly must be identical to the one supplied with the
unit. To inspect the hose assembly, check under the
unit through access opening in the enclosure.
•Insureproperinstallation.Havetheinstallershow
you where the gas supply shutoff valve is located, and
how to shut off the gas to the cooktop. Always adhere
to the minimum clearances to combustible materials as
specified in Section 3.
• Do not repair or replace any part of this
appliance unless specifically recommended in this
manual. All other servicing should be referred to a
qualified service technician.
Keep the area around the appliance clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.
• If you smell gas when the unit is not in use, have the
unit checked for leaks as defined in Section 6. Finding a
gas leak is not a do-it-yourself procedure as some leaks
can only be found with the burner control in the ON
position. This must be done by a qualified technician.
Do not place any items in front of the unit while in use.
This could obstruct the proper flow of air needed for
proper combustion and ventilation.
• If you smell gas when the unit is in use, immediately
shut off all controls. Let the gas dissipate for at least five
minutes. Relight the burner(s) and verify that they are
operating properly. If the burner(s) fail to relight or are
not operating properly, shut of the gas to the unit and
have the unit checked by a qualified service technician.
Keepventilationopening(s)oftheLPcylinderenclosure
free and clear of obstructions and debris.
Keep electrical supply cord and the fuel supply hose
away from any heated surfaces.
• This appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not cut
or remove the grounding prong from this plug.
Do not leave the cooktop unattended while
cooking.
• Be aware that spiders and insects can nest in
the burners of this cooktop. This can obstruct the
proper flow of gas into the burner and cause improper
operation, fire hazard and potential damage to the unit.
Inspect the burners periodically, or immediately if any
of the symptoms denoted in Section 7 exist. Check
Burner Air Adjustment, Page 12.
Warning: California Proposition 65 B
potential exposure to such substances. To
minimize exposure to these substances, always
operate this unit according to the instructions
contained in this booklet and provide good
ventilation when cooking with gas.
The burning of gas cooking fuel generates some
by-products that are on the list of substances
which are known by the State of California to
cause cancer or reproductive harm. California
law requires businesses to warn customers of
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1: SAFETY PRACTICESTO AVOID PERSONAL INJURY
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING YOUR COOKTOP
LP TANK REQUIREMENTS
FOR YOUR SAFETY
This model can be converted for use with an LP cylinder
•The gas supply must be turned off at the
which can be purchased locally from an LP supplier or
LP-gas supply cylinder when this outdoor
other retail outlet. The cylinder must be constructed
cooking gas appliance is not in use.
and marked in accordance with the specifications for
• The LP-gas supply cylinder must be dis-
LP-gas cylinders of the U.S. Department of
connected when this outdoor cooking gas
Transportation (DOT) or the National Standard of
appliance is not in use.
Canada, CAN/CSA-B339, Cylinder, Spheres and Tubes
fortheTransportationofDangerousGoods.Tominimize
AVERTISSEMENT
the potential for fire or an explosion, the following
precautions should be observed when using, filling or
storing an LP cylinder:
• L’alimentation du gaz doit étre fennée a
la bouteille de gaz de pétrole liquéfié,
lorsque cet appareil de cuisson extérieur
n’ est pas utilisé.
• Never use a dented or rusty LP tank. If there is
any question as to the soundness of the tank, have it
checked by your LP supplier.
• La bouteille d’alimentation en gaz de
pétrole liquéfié doit étre débranchée,
lorsque cet appareil de cuisson extérieur
n’est pas utilisé.
• Never use a tank with a damaged or defective
shut off valve.
• Always close the tank shut off valve after use.
• Do not overfill the LP cylinder. Never fill the LP
cylinder beyond eighty percent (80%) of its capacity.
Overfilling will cause the pressure relief valve on the
cylinder to vent excess gas vapor. This vapor is
combustible and can ignite, causing a fire.
FORYOUR SAFETY
An LP cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
• When transporting an LP cylinder, insure it is in
an upright position and away from any sources of high
heat.
AVERTISSEMENT
Une bouteille de propane qui n’est pas
raccordée en vue de son utilisation,ne doit
pas etre entreposée dans le voisinage de cet
appareil ou de tout autre appareil.
• Do not store additional LP cylinders inside the
enclosure for the unit. Cylinders must be stored
outdoors in a well-ventilated area out of direct sunlight
and/or sources of high heat, and out of the reach of
children.
•LPcylindersupplysystemmustbearrangedfor
vapor withdrawal.
FORYOUR SAFETY
For Outdoor Use Only. If stored indoors,
detach and leave cylinder outdoors.
• LP cylinder used must include a collar to protect
the cylinder valve.
• The LP cylinder must be disconnected and
removed from the applianceif the appliance is to be
stored indoors.
AVERTISSEMENT
Pour utlilisation a la l’extérieur seulement.
Si l’appareil est entreposé à l’intérieur,
enlever les bouteilles et les laisser a
l’extérieur.
• Always check for leaks after every cylinder
change. See Section 6 of Installation Instructions.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 2: GAS REQUIREMENTS
NATURAL GAS REQUIREMENTS -
Inlet Connection: 1/2" NPT
!
IMPORTANT
L
Supply Pressure: 6" to 14" W.C.
Manifold Pressure: 5" W.C.
A manual gas shut off valve must be installed
externaltotheappliance,inalocationaccessible
with the unit installed in the enclosure. Make
sure the valve is turned off prior to connecting
the appliance.
PROPANE GAS REQUIREMENTS -
Inlet Connection: 1/2" NPT
Supply Pressure: 11" to 14" W.C.
Manifold Pressure: 10" W.C.
!
IMPORTANT
L
Un robinet manuel d'isolement doit étre installé à
l’extérieur de l’appareil, dans un emplacement
accessible avec l’unité installée dans la module.
Assurez-vous que le robinet est fermé avant de
brancher l’appareil.
GAS CONSUMPTION
The total gas consumption of the Thermador® Outdoor
Cooktop with all burners on "HI" is 30,000 BTU/HR.
!
L
CAUTION
!
CAUTION
L
The appliance must be isolated from the gas
supply system by closing its individual manual
shut-off valve during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 1/2" psig (3.5kPa).
Whenconnectingtopropanegassupply, make
certain that the propane gas tank is equipped
withitsownhighpressureregulatorinaddition
to the pressure regulator supplied with the
appliance. The pressure of the gas at the
applianceregulatormustnotexceed14"water
column.
When checking the manifold gas pressure, the
inletpressuretotheapplianceregulatorshould
be at least 7.0" W.C. for natural gas, and 11.0"
W.C. for propane.
!
L
ATTENTION
Donotattemptanyadjustmentofthepressure
regulator.
En se reliant a l approvisionnement de gaz de
propane, assurez-vous que le réservoir de gaz
depropaneestéquipédesonProprerégulateur
à haute pression en peus du régulateur de
Pression fourni avec l’appareil. La pression du
gaz au régulateur de l’appareil ne doit pas
exéceder 26.1 mm HG.
!
L
ATTENTION
L’appareil doit étre isolé du circuit
d’alimentation de gaz en fermant son rob1net
manuel d’isolement individuel pendant toutes
essais sous pression du circuit de tuyauterie
d’alimentation de gaz aux pressions d’essai
égales à ou moins de 3.5kPa (1/2 psig).
For Massachusetts Installations:
En controlant la pression de gaz du tubulure, la
pression de prise au régulateur de l’appareil
devrait étre au moins 11.2mm HG pour gaz
naturel, et 20.5mm HG pour gaz de propane.
1. Shut-offvalvemustbea“T”handlegascock.
2. Flexible gas connector must not be longer
than 36 inches.
3. Not approved for installation in a bedroom
or a bathroom unless unit is direct vent.
N’essayez aucun réglage du régulateur de
pression.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3: SITE PREPARATION
BUILT-IN INSTALLATIONS
CABINET PREPARATION
Determine a suitable location for the cooktop by taking
into account exposure to wind and availability of gas and
electrical supplies. Insure that the gas supply line and
electrical supply are located in close proximity to the
unit.
The model SB2B is designed for easy installation into
masonry enclosures. For noncombustible applications,
the cooktop drops into the opening shown in Figure 1
(below). A ledge is required to support the cooktop
from the bottom. The supporting ledges must be level
and flat. The counter top should also be level.
The 8-foot-long electrical cord attached to the cooktop
exits from the bottom, left rear corner of the rough-in
box. Keep connections to the unit as short as possible
and allow for installation and removal of the unit from
the enclosure.
It is recommended that ventilation holes are provided in
the enclosure in the event of a gas leak. The installer-
supplied gas shut-off valve must be installed in an easily
accessible location.
Allow adequate area around the unit for dissipation of
smoke produced during cooking.
Combustible Construction Clearances
Figure 1
Non-Combustible Enclosure for
SB2B Cooktop
Minimum horizontal clearance from sides and back of
unit to adjacent vertical combustible construction ex-
tending above top of unit, 12" from sides and 12" from
back.
36"
3" Min.
Degagement horizontal minimal a respecter entre les
cotes et l’arriere de l’appareil et une construction
combustible verticale adjacent depassant la partie
superieure de l’appareil, soit 12" (305mm) pounces des
cotes et 12" (305mm) ponces de l’arriere.
-5
12 /8"
-3
22 /4"
Below the cooking surface, combustible construction
can be placed directly adjacent to the unit.
Non-combustible Construction Clearances
36"
Above the cooking surface, a minimum of 12" clearance
from the sides is required to allow adequate access to
pans. A minimum of 3" clearance from the rear is
required to allow for large pan sizes. Below the cooking
surface, non-combustible construction can be placed
directly adjacent to the unit.
-3
11 /4"
In all installations, do not locate this outdoor cooking
gas appliance under unprotected combustible overhead
construction.
2" x 4" x 18"
WOOD SUPPORT
II est interdit d’installer le present appareil au-dessous
des surfaces combustibles non protegees.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 4: ELECTRICAL REQUIREMENTS
AND GROUNDING INSTRUCTIONS
CAUTION
CAUTION
Installation of electrical supply circuit should be
done by a qualified electrician in accordance with
local codes and ordinances. In the absence of local
codesorordinances,thesupplyshouldbeinstalled
in accordance with the National Electric Code
ANSI/NFPA No. 70, current issue, or Canadian
Electric Code C22.1 Part 1.
The Thermador® Outdoor Cooktop uses an
electronic ignition system that requires a 120
VAC, 15A, 60 Hz power supply. A properly
groundedduplexoutletmustbeprovidedadjacent
to the lower left rear corner of the unit. See
Figure 2 (below).
Figure 2
WARNING
Electrical Grounding Instructions
This outdoor cooking gas appliance is
equipped with a three-prong (grounding)
plug for your protection against shock haz-
ard and should be plugged directly into a
properly grounded three-prong receptacle.
Do not cut or remove the grounding prong
from this plug.
AVERTISSEMENT
Instruction pour la mise
a la terre electrique
Cet appareil est muni d’une fiche a trots
broches(misealaterre)afindevousproteger
des chocs et doit etre branche dire~ement
dans une prise de courant a trots broches
adequatement mise a la tem. II ne faut pas
couperouenleverlabrochedemisealatem
de cette fiche.
Cooktop Three-Prong Plug and Receptacle
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 5: UNPACKING AND PLACINGTHE UNIT
LOCATINGYOUR
OUTDOOR COOKTOP
The following steps are necessary to
convert for LP operation:
Unpackandremoveallaccessoryitems,packingmaterials
and product literature from the unit. Attach the gas
pressure regulator to the end of the manifold as shown
in Figure 3. Note the direction of gas flow. Connect one
end of an approved outdoor gas supply hose to the
regulator inlet. Connect the opposite end of the hose
to the installer supplied shut-off valve. Refer to Section
2 for gas requirements.
1. Remove the grate,
burner caps, ven–
turis and burner
bases.
See Figure 4.
FIGURE 3 – NATURAL GAS HOOK-UP
2. Remove the burn-
er orifices. Use a
7mm hex socket
on a 3" ratchet
extension and
apply a piece of
foam tape to the
socket to hold the
orifice in the
socket while re-
moving.
Regulator 5.0" W.C.
1/2" NPT
Close Nipple
See Figure 5.
Adapter 1/2" NPT
3. Replace with the
LPorificessupplied
(number 115).
Tighten until snug.
See Figure 6.
to 3/8" flare fitting
Threading compound
must be resistant to
L.P. gas
Installer supplied
shut-off Valve must
be easily accessible
Gas Hose
(not supplied)
4. Reassemble the
burner bases and
venturis. Reinstall
burner caps and
grate.
CONVERSION FROM NATURAL
GASTO LP (LIQUID PROPANE)
Model SB2B is manufactured at the factory for use with
natural gas, and as such requires conversion for use
with an LP gas supply. The conversion should be done
byaqualifiedtechnicianoryourgassupplier. Allorifices
required for conversion are provided with the unit.
Steps continue on
next page
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 5: UNPACKING AND PLACINGTHE UNIT
FIGU
FIGU
5. The bypass jet must be turned clockwise with a
smallflat-bladedscrewdriveruntilfullyseatedtoset
properlowflowrate. SeeFigures7and8, above.
6. The cooktop is supplied with a pressure regulator
that is packed with the unit. The regulator is set
for natural gas. For use with propane, it must be
converted. The regulator will be located on the
left rear bottom of the unit. Using a flat blade
screwdriver, remove the cap on the top of the
regulator and turn the cap over so that the letters
LP are exposed. Make sure the spring in the
regulator remains in position. Reattach the cap to
the regulator. See Figure 9, right.
FIGURE 9
Steps continue on next page
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 5: UNPACKING AND PLACING THE UNIT
7. If the cooktop will be used with an LP cylinder,
follow these steps:
A. The Model LPHose is available at your
Thermador dealer.
B. This assembly can also be purchased locally
providing it meets the following specifications:
©
Bottom of
unit
Hose length to be 24".
Regulator must be a high pressure, high volume
unit capable of supplying adequate gas flow
based on the input rating of the unit (refer to
Gas Consumption in Section 2).
➚
C
t
t
r
Regulator Adapter
➚
The inlet connector on the LP regulator must
be compatible with the LP cylinder valve.
The hose and regulator assembly must be AGA
certified for use with LP gas in an outdoor
application.
➚
Collar
C. Install a 1/2" NPT coupling at the end of the
manifold located at the left rear bottom of the
cooktop. Use a pipe sealant approved for use
with LP gases on all threads.
D. Attach gas regulator hose assembly to the
coupling as shown in Figure 10, right.
E. Connect the gas regulator assembly to the LP
tank valve.
F. Turn on the gas supply but do not attempt to
light any burner. Check the unit for leaks per
the instructions in Section 6.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 6:TEST AND ADJUSTMENT
GAS AND ELECTRICAL HOOK-UP
With the unit inside of the enclosure, connect the
gas supply hose to the manual shut-off valve and
open valve. Check the connection points at the
shut-off valve for any leaks and repair prior to
installation of the unit. See Figures 11 and 12.
Connect the power supply cord to the electrical
supply outlet.
CHECKING FOR LEAKS
All points of connection to the gas supply should be
checked for leaks at time of installation or anytime
you smell gas. It is also advisable to recheck them
periodically. Follow the steps outlined below:
Bottom of Unit
s
Tank
Valve
A. Makeasoapsolutionofonepartliquiddetergent
and one part water.
B. Makesureallcontrolsareinthe"OFF"position.
Turn on the gas supply to the unit. Use a spray
bottle, brush or rag to apply the solution to all
fittingsandpointsofconnectionfromthesupply
stub out up to and including the inlet to the
manifold. See Figures 11 and 12. Bubbles will
form where a leak exists.
Regulator
Assembly
LP Tank
C. If a leak is present, shut off the gas at the supply.
Tighten any leaking fittings, turn on the gas and
recheck.
Leak Test Points
Figure 12 Leak Test Points – Plumbed Gas Supply
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 6:TEST AND ADJUSTMENT
ꢀ INSTALLER CHECKLIST ꢀ
INSTALLATION
GAS SUPPLY
— Appliance is connected to the proper type of
gas supply.
— Placement of unit.
— Specified clearances maintained to combustible
or noncombustible surfaces as applicable.
— The burner box area is free of any packing
materials and that the burners are properly
located and installed.
— Manual gas shut off valve is installed in an
accessible location (with unit installed in
enclosure for built-in installations).
— Burner caps properly positioned and seated on
burner bases.
— Unit tested and free from gas leaks.
— Gas supply pressure does not exceed 14" W.C.
ELECTRICAL
— Properly grounded receptacle is present for
unit.
— If the unit is to be used with propane gas, verify
that the LP gas supply has its own high pressure
regulator.
WARNING: Remove the stainless steel burner cover before attempting to
light the appliance. Failure to remove the cover could allow gas to accumulate
which could cause an explosion.
IFYOU SMELL GAS, DO NOT ATTEMPTTO LIGHT ANY BURNERS.
BURNER AIRADJUSTMENT
LIGHTING INSTRUCTION
For Electronic Ignition:
All burners are adjusted for proper flame
characteristics at time of assembly.
1. Make sure that all knobs are turned to the OFF
position.
Allburnersshouldexhibitflameswhichareblueand
stable, with no yellow-tipping, lifting or excessive
noise when operating on either natural or LP gases.
2. Turn the knob to LITE position and immediately
press the ignition switch. The burner will light
within 4-10 seconds.
If any of the flame characteristics noted above are
observed, check the burner for dirt or residue in
the ports, spider webs, etc., and clean or repair as
necessary.
3. Adjust control knob to the desired flame setting.
For Manual Ignition:
1. Check that the burner caps are in correct
position, shown on Page 13.
2. Turn control knob to the “LITE” position.
3. Place the lighted match on the burner cap ports.
4. Adjustcontrolknobtothedesiredflamesetting.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7: USING YOUR OUTDOOR COOKTOP
GENERAL BURNER INFORMATION
Porcelain
Enamel Cap
•
•
Each burner is rated at 15,000 BTU on High.
Choose a pan base to fit the flame size. The
flameshouldneverextendbeyondthebaseof
the pan.
BURNER CAP
•
•
Neverturnonaburnerwithoutremovingthe
cover.
Ports
TAB A
When not in use, place the stainless steel
cover over the grate.
Igniter
USING THE BURNERS
NOTCH B
1. Remove the burner cover.
FIGURE 13 – Burner Base
2. Check that the burner caps are in the correct
position. Tab A on the cap fits notch B on the
base.
3. Put grate in position.
4. Follow Lighting Instructions on Page 12.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 8: CARE AND CLEANING
PART and MATERIAL
SUGGESTED CARE
The quality of this material resists most stains and pitting, providing
the surface is kept clean and protected with a stainless steel polish.
Nonabrasive Cleaners: detergent and water, Fantastik®, 409®, vinegar.
Mild abrasive Cleaners: liquid Kleen King®
Exterior Finish/Cover
Stainless Steel
Stainless Steel Polish: Stainless Steel Magic®
Grates
Porcelain Enamel
on Cast Iron
• When removing the grates, care should be taken in lifting them. Be
sure to place the grate on a protected surface.
NOTE:Grateswilldevelopbilstersandchipsintheporcelainwithusedue
to the extreme operating temperatures
Hotsudsywaterandmildabrasivecleaners:Bon-ami®,SoftScrub®.
For stubborn stains: a soap fllled steel wool pad.
• Wash, rinse and dry. The occasional use of mild abrasive cleaners or
steel wool soap-filled pad is okay. Abrasive cleaners, used vlgorously
ortoooften, caneventuallyharmtheenamel. Applywithadampsponge,
rinse thoroughly and dry.
Burner Ports and Caps
Aluminum/Porcelain
Make certain that burners are turned OFF before cleaning.
Ports – Clear ports of any soil with a Wire, straightened paper clip
or needle. Wash in hot sudsy water. Rinse and dry.
Caps – Wash in hot sudsy water. Rinse and dry. For hard-to-remove soil,
use powdered cleaners such as Ajax®, Bon-ami®, Comet®.
Hot sudsy water.
Control Knobs, Bezels
Plastic/Chrome
• Pull knobs straight forward. Wash, do not soak. Rinse, dry and replace.
Make certain the knobs are reinstalled In the proper location. Do not
force knobs onto wrong control.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 9: SERVICE
Troubleshooting
Before Phoning for Service
Power Failure - In the event of a power failure, the Thermador® Outdoor Cooktop may still be used by lighting
the burners with a match.
If Burners Fail to Ignite - If the burners fail to ignite
verify that the unit is connected to a properly
grounded duplex outlet. If electricity is present,
look for spark to jump from the spark ignitor to
the burner when the ignition switch is depressed
and held. Make sure that the spark ignitors and
burners are clean and dry. Verify that burner caps
are in the correct position on the burner bases.
Service Information
The data rating label shows the model and serial
numberforyourcooktop..Italsogivesinformation
regarding burner rating and installation
requirements.. The data rating label is located on
the underside of the unit. For handy reference,
copy the information below from the data rating
label. Keep your invoice for warranty validation.
__________________________________
Model Number
To Obtain Replacement Parts, order
__________________________________
Serial Number
from the dealer where the unit was purchased
or dial the telephone number listed below.
__________________________________
Date of Purchase
HOW TO OBTAIN SERVICE
__________________________________
For authorized service or parts information, phone
Dealer’s Name
800/735-4328. We want you to remain a satisfied
customer. If a problem does come up that cannot be
__________________________________
resolved to your satisfaction, please let us know.
Dealer’s Phone Number
Write: Thermador® Customer Call Center, 5551
McFadden Avenue, Huntington Beach CA 92649 or
__________________________________
phone 800/735-4328. Please provide us with the Model
Service Center’s Name
Number, Serial Number and Date of Original Purchase/
Installation.
__________________________________
Service Center’s Phone Number
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 10: WARRANTY
Warranty
This warranty applies to appliances used in residential
application; it does not cover their use in commercial
installations.
Full One-YearWarranty
Covers one year from the date of installation or date of
occupancy for a new previously unoccupied dwelling.
Save your dated receipt or other evidence of the
installation/occupancy date.
This warranty is for products purchased and retained
in the 50 states of the U.S.A., the District of Columbia
andCanada.Shouldtheappliancebesoldbytheoriginal
purchaser during the warranty period, the new owner
continues to be protected until the expiration date of
theoriginalpurchaser’swarrantyperiod. Thewarranty
applies even if you should move.
Thermador® Will Pay For:
All repair labor and replacement parts found to be
defective due to materials and workmanship. Service
must be provided by a Factory Authorized Service
Agency during normal working hours. For a Service
Agency nearest you, please call 800/735-4328.
Thermador Will Not Pay For:
THERMADOR DOES NOT ASSUME ANY
RESPONSIBILITY FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES. Some states do
not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or
exclusionmaynotapplytoyou.Thiswarrantygivesyou
specific legal rights and you may also have other rights
which may vary from state to state or province to
province.
1. Service by an unauthorized agency. Damage or
repairsduetoservicebyanunauthorizedagencyor
the use of unauthorized parts.
2. Service visits to:
• Teach you how to use the appliance.
• Correct the installation. You are responsible for
providing electrical wiring and other connecting
facilities.
• Reset circuit breakers or replace home fuses.
3. Damage caused from accident, alteration, misuse,
abuse, improper installation or installation not in
accordance with local electrical codes or plumbing
codes, or improper storage of the appliance.
4. Repairs due to other than normal home use.
5. Any service visits and labor costs during the limited
warranty.
6. Travel fees and associated charges incurred when
the product is installed in a location with limited or
restrictedaccess,(i.e.,airplaneflights,ferrycharges,
isolated geographic regions).
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to
making counter opening. Consult with a heating and ventilating engineer for your specific ventilation requirements. For the
most detailed information, refer to installation instructions accompanying product or write Thermador indicating the model
number.
Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada.
Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your
local Canadian distributor or dealer. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649.
For the most up to date critical installation dimensions by fax, use your fax handset
and call 702/833-3600. Use code #8030.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328
ECO14028 • 08-04-638B • © BSH Home Appliances Corp. • Litho U. S. A. 4/00
Download from Www.Somanuals.com. All Manuals Search And Download.
|