Thermador Cooktop SB2B User Manual

Installation Instructions  
and  
Owner's Manual  
for  
Thermador  
Outdoor Cooktop  
Model SB2B  
Installer: Please leave these instructions with the unit for the owner.  
Owner: Please retain these instructions for future reference.  
WARNING:If the information in this manual is not followed exactly,a fire or  
L explosion may result causing property damage, personal injury or death.  
!
AVERTISSEMENT: Si l’information dans ce manuel n’est pas suivie exactement,  
une incendie ou une explosion peut résulter, entrainant des dégats matériels, des  
blessures ou la mort.  
!
L
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
SECTION 1: Safety Information ............................................................. 2-4  
SECTION 2: Gas Requirements................................................................... 5  
Natural Gas Requirements .......................................................................... 5  
Propane Gas Requirements ......................................................................... 5  
Gas Consumption .......................................................................................... 5  
SECTION 3: Site Preparation...................................................................... 6  
Built-In Installations ....................................................................................... 6  
Cabinet Preparation ...................................................................................... 6  
SECTION 4: Electrical Cautions .................................................................. 7  
Electrical Requirements................................................................................ 7  
Grounding Instructions................................................................................. 7  
SECTION 5: Unpacking, Moving and Placing the Unit ....................8 - 10  
Locating your Char Glo® Barbecue ........................................................... 8  
Natural Gas Hook-up ................................................................................... 8  
Natural Gas to Liquid Propane Conversion ....................................8 - 10  
Liquid Propane Hook-up ............................................................................ 10  
SECTION 6:Test andAdjustment........................................................ 11,12  
Checking for Leaks ...................................................................................... 11  
Installer Checklist......................................................................................... 12  
Lighting Instructions .................................................................................... 12  
Burner Air Adjustment................................................................................ 12  
SECTION 7: UsingYour Outdoor Cooktop ........................................... 13  
SECTION 8: Care and Cleaning................................................................. 14  
SECTION 9: Service ..................................................................................... 15  
SECTION 10:Warranty............................................................................... 16  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1: SAFETY INFORMATION  
FOR YOUR SAFETY  
AVERTISSEMENT  
S’il y a une odeur de gaz:  
If you smell gas:  
1. Shut off gas to the appliance.  
2. Extinguish any open flame.  
1. Coupez l’admission de gaz de l’appariel.  
2. Ènteindre toute flamme nue.  
3. If odor continues,immediately call your gas  
supplier or your fire department.  
3. Si l’odeur peraiste,appeler immediatement  
votre compagnie de gaz ou votre  
departement des incendies.  
FOR YOUR SAFETY  
AVERTISSEMENT  
1. Ne pas entreposer ni utiliser de l‘essence  
ni d’autres vapeurs ou liquides  
inflammables dans le voisinage de l’appareil,  
ni de tout autre appareil.  
1. Do not store or use gasoline or other flam-  
mable vapors and liquids in the vicinity of  
this or any other appliance.  
2. An LP cylinder not connected for use shall  
not be stored in the vicinity of this or any  
other appliance.  
2. Une bouteille de propane qui n’est pas  
raccordée en vue de son utilisation,ne doit  
pas etre entreposée dans le voisinage de  
cet appareil ou de tout autre appareil.  
Installation and service must be performed by a qualified installer,  
service agency or the gas supplier.  
TESTED IN ACCORDANCE WITH ANSI Z21.58 – 1995, ANSI Z21.58a – 1998 STANDARD FOR  
OUTDOOR COOKING GAS APPLIANCES, AND CAN/CGA 1.6 – M95, CGA 1.6a – M98,  
STANDARD FOR OUTDOOR COOKING GAS APPLIANCES.  
This unit is for outdoor use only in a well-ventilated area. Not to be  
used in a building, garage or any other enclosed area.  
Check your local building codes for the proper method of installation. In the absence of local codes this  
unit should be installed in accordance with the National Fuel Gas Code No. Z223.1 Current Issue and  
National Electrical Code ANSI/NFPA No. 70 Current Issue or the CAN/CGA – B149.1 Natural Gas  
Installation Code or CAN/CGA - B149.2 Propane Installation Code and C22.1 Canadian Electrical Code,  
Part 1.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1: SAFETY PRACTICESTO AVOID PERSONAL INJURY  
WARNINGS FOR SAFE GAS INSTALLATIONS  
IMPORTANT INFORMATION  
GENERAL SAFETY PRECAUTIONS  
This outdoor gas cooking appliance is not intended to  
be installed in or on recreational vehicles and/or boats.  
Readthismanualcarefullybeforeusingthecooktop  
to reduce the risk of fire, electric shock, or injury to  
persons.  
Always inspect the natural gas or LP gas hose assembly  
before each use of the appliance. If there is evidence of  
excessive abrasion or wear, or if the hose is cut, it must  
be replaced prior to the appliance being put into  
operation. Replacement hose assemblies can be  
purchasedatbarbecuesupplystores,ororderedthrough  
Thermador®. If purchased at a retail outlet, the hose  
assembly must be identical to the one supplied with the  
unit. To inspect the hose assembly, check under the  
unit through access opening in the enclosure.  
Insureproperinstallation.Havetheinstallershow  
you where the gas supply shutoff valve is located, and  
how to shut off the gas to the cooktop. Always adhere  
to the minimum clearances to combustible materials as  
specified in Section 3.  
• Do not repair or replace any part of this  
appliance unless specifically recommended in this  
manual. All other servicing should be referred to a  
qualified service technician.  
Keep the area around the appliance clear and free from  
combustible materials, gasoline and other flammable  
vapors and liquids.  
• If you smell gas when the unit is not in use, have the  
unit checked for leaks as defined in Section 6. Finding a  
gas leak is not a do-it-yourself procedure as some leaks  
can only be found with the burner control in the ON  
position. This must be done by a qualified technician.  
Do not place any items in front of the unit while in use.  
This could obstruct the proper flow of air needed for  
proper combustion and ventilation.  
• If you smell gas when the unit is in use, immediately  
shut off all controls. Let the gas dissipate for at least five  
minutes. Relight the burner(s) and verify that they are  
operating properly. If the burner(s) fail to relight or are  
not operating properly, shut of the gas to the unit and  
have the unit checked by a qualified service technician.  
Keepventilationopening(s)oftheLPcylinderenclosure  
free and clear of obstructions and debris.  
Keep electrical supply cord and the fuel supply hose  
away from any heated surfaces.  
• This appliance is equipped with a three-prong  
(grounding) plug for your protection against  
shock hazard and should be plugged directly into a  
properly grounded three-prong receptacle. Do not cut  
or remove the grounding prong from this plug.  
Do not leave the cooktop unattended while  
cooking.  
• Be aware that spiders and insects can nest in  
the burners of this cooktop. This can obstruct the  
proper flow of gas into the burner and cause improper  
operation, fire hazard and potential damage to the unit.  
Inspect the burners periodically, or immediately if any  
of the symptoms denoted in Section 7 exist. Check  
Burner Air Adjustment, Page 12.  
Warning: California Proposition 65 B  
potential exposure to such substances. To  
minimize exposure to these substances, always  
operate this unit according to the instructions  
contained in this booklet and provide good  
ventilation when cooking with gas.  
The burning of gas cooking fuel generates some  
by-products that are on the list of substances  
which are known by the State of California to  
cause cancer or reproductive harm. California  
law requires businesses to warn customers of  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1: SAFETY PRACTICESTO AVOID PERSONAL INJURY  
IMPORTANT SAFETY INSTRUCTIONS  
READ ALL INSTRUCTIONS BEFORE USING YOUR COOKTOP  
LP TANK REQUIREMENTS  
FOR YOUR SAFETY  
This model can be converted for use with an LP cylinder  
The gas supply must be turned off at the  
which can be purchased locally from an LP supplier or  
LP-gas supply cylinder when this outdoor  
other retail outlet. The cylinder must be constructed  
cooking gas appliance is not in use.  
and marked in accordance with the specifications for  
• The LP-gas supply cylinder must be dis-  
LP-gas cylinders of the U.S. Department of  
connected when this outdoor cooking gas  
Transportation (DOT) or the National Standard of  
appliance is not in use.  
Canada, CAN/CSA-B339, Cylinder, Spheres and Tubes  
fortheTransportationofDangerousGoods.Tominimize  
AVERTISSEMENT  
the potential for fire or an explosion, the following  
precautions should be observed when using, filling or  
storing an LP cylinder:  
• L’alimentation du gaz doit étre fennée a  
la bouteille de gaz de pétrole liquéfié,  
lorsque cet appareil de cuisson extérieur  
n’ est pas utilisé.  
• Never use a dented or rusty LP tank. If there is  
any question as to the soundness of the tank, have it  
checked by your LP supplier.  
• La bouteille d’alimentation en gaz de  
pétrole liquéfié doit étre débranchée,  
lorsque cet appareil de cuisson extérieur  
n’est pas utilisé.  
• Never use a tank with a damaged or defective  
shut off valve.  
• Always close the tank shut off valve after use.  
• Do not overfill the LP cylinder. Never fill the LP  
cylinder beyond eighty percent (80%) of its capacity.  
Overfilling will cause the pressure relief valve on the  
cylinder to vent excess gas vapor. This vapor is  
combustible and can ignite, causing a fire.  
FORYOUR SAFETY  
An LP cylinder not connected for use shall  
not be stored in the vicinity of this or any  
other appliance.  
• When transporting an LP cylinder, insure it is in  
an upright position and away from any sources of high  
heat.  
AVERTISSEMENT  
Une bouteille de propane qui n’est pas  
raccordée en vue de son utilisation,ne doit  
pas etre entreposée dans le voisinage de cet  
appareil ou de tout autre appareil.  
• Do not store additional LP cylinders inside the  
enclosure for the unit. Cylinders must be stored  
outdoors in a well-ventilated area out of direct sunlight  
and/or sources of high heat, and out of the reach of  
children.  
LPcylindersupplysystemmustbearrangedfor  
vapor withdrawal.  
FORYOUR SAFETY  
For Outdoor Use Only. If stored indoors,  
detach and leave cylinder outdoors.  
LP cylinder used must include a collar to protect  
the cylinder valve.  
• The LP cylinder must be disconnected and  
removed from the applianceif the appliance is to be  
stored indoors.  
AVERTISSEMENT  
Pour utlilisation a la l’extérieur seulement.  
Si l’appareil est entreposé à l’intérieur,  
enlever les bouteilles et les laisser a  
l’extérieur.  
• Always check for leaks after every cylinder  
change. See Section 6 of Installation Instructions.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: GAS REQUIREMENTS  
NATURAL GAS REQUIREMENTS -  
Inlet Connection: 1/2" NPT  
!
IMPORTANT  
L
Supply Pressure: 6" to 14" W.C.  
Manifold Pressure: 5" W.C.  
A manual gas shut off valve must be installed  
externaltotheappliance,inalocationaccessible  
with the unit installed in the enclosure. Make  
sure the valve is turned off prior to connecting  
the appliance.  
PROPANE GAS REQUIREMENTS -  
Inlet Connection: 1/2" NPT  
Supply Pressure: 11" to 14" W.C.  
Manifold Pressure: 10" W.C.  
!
IMPORTANT  
L
Un robinet manuel d'isolement doit étre installé à  
l’extérieur de l’appareil, dans un emplacement  
accessible avec l’unité installée dans la module.  
Assurez-vous que le robinet est fermé avant de  
brancher l’appareil.  
GAS CONSUMPTION  
The total gas consumption of the Thermador® Outdoor  
Cooktop with all burners on "HI" is 30,000 BTU/HR.  
!
L
CAUTION  
!
CAUTION  
L
The appliance must be isolated from the gas  
supply system by closing its individual manual  
shut-off valve during any pressure testing of  
the gas supply piping system at test pressures  
equal to or less than 1/2" psig (3.5kPa).  
Whenconnectingtopropanegassupply, make  
certain that the propane gas tank is equipped  
withitsownhighpressureregulatorinaddition  
to the pressure regulator supplied with the  
appliance. The pressure of the gas at the  
applianceregulatormustnotexceed14"water  
column.  
When checking the manifold gas pressure, the  
inletpressuretotheapplianceregulatorshould  
be at least 7.0" W.C. for natural gas, and 11.0"  
W.C. for propane.  
!
L
ATTENTION  
Donotattemptanyadjustmentofthepressure  
regulator.  
En se reliant a l approvisionnement de gaz de  
propane, assurez-vous que le réservoir de gaz  
depropaneestéquipédesonProprerégulateur  
à haute pression en peus du régulateur de  
Pression fourni avec l’appareil. La pression du  
gaz au régulateur de l’appareil ne doit pas  
exéceder 26.1 mm HG.  
!
L
ATTENTION  
L’appareil doit étre isolé du circuit  
d’alimentation de gaz en fermant son rob1net  
manuel d’isolement individuel pendant toutes  
essais sous pression du circuit de tuyauterie  
d’alimentation de gaz aux pressions d’essai  
égales à ou moins de 3.5kPa (1/2 psig).  
For Massachusetts Installations:  
En controlant la pression de gaz du tubulure, la  
pression de prise au régulateur de l’appareil  
devrait étre au moins 11.2mm HG pour gaz  
naturel, et 20.5mm HG pour gaz de propane.  
1. Shut-offvalvemustbeaThandlegascock.  
2. Flexible gas connector must not be longer  
than 36 inches.  
3. Not approved for installation in a bedroom  
or a bathroom unless unit is direct vent.  
N’essayez aucun réglage du régulateur de  
pression.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3: SITE PREPARATION  
BUILT-IN INSTALLATIONS  
CABINET PREPARATION  
Determine a suitable location for the cooktop by taking  
into account exposure to wind and availability of gas and  
electrical supplies. Insure that the gas supply line and  
electrical supply are located in close proximity to the  
unit.  
The model SB2B is designed for easy installation into  
masonry enclosures. For noncombustible applications,  
the cooktop drops into the opening shown in Figure 1  
(below). A ledge is required to support the cooktop  
from the bottom. The supporting ledges must be level  
and flat. The counter top should also be level.  
The 8-foot-long electrical cord attached to the cooktop  
exits from the bottom, left rear corner of the rough-in  
box. Keep connections to the unit as short as possible  
and allow for installation and removal of the unit from  
the enclosure.  
It is recommended that ventilation holes are provided in  
the enclosure in the event of a gas leak. The installer-  
supplied gas shut-off valve must be installed in an easily  
accessible location.  
Allow adequate area around the unit for dissipation of  
smoke produced during cooking.  
Combustible Construction Clearances  
Figure 1  
Non-Combustible Enclosure for  
SB2B Cooktop  
Minimum horizontal clearance from sides and back of  
unit to adjacent vertical combustible construction ex-  
tending above top of unit, 12" from sides and 12" from  
back.  
36"  
3" Min.  
Degagement horizontal minimal a respecter entre les  
cotes et l’arriere de l’appareil et une construction  
combustible verticale adjacent depassant la partie  
superieure de l’appareil, soit 12" (305mm) pounces des  
cotes et 12" (305mm) ponces de l’arriere.  
-5  
12 /8"  
-3  
22 /4"  
Below the cooking surface, combustible construction  
can be placed directly adjacent to the unit.  
Non-combustible Construction Clearances  
36"  
Above the cooking surface, a minimum of 12" clearance  
from the sides is required to allow adequate access to  
pans. A minimum of 3" clearance from the rear is  
required to allow for large pan sizes. Below the cooking  
surface, non-combustible construction can be placed  
directly adjacent to the unit.  
-3  
11 /4"  
In all installations, do not locate this outdoor cooking  
gas appliance under unprotected combustible overhead  
construction.  
2" x 4" x 18"  
WOOD SUPPORT  
II est interdit d’installer le present appareil au-dessous  
des surfaces combustibles non protegees.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4: ELECTRICAL REQUIREMENTS  
AND GROUNDING INSTRUCTIONS  
CAUTION  
CAUTION  
Installation of electrical supply circuit should be  
done by a qualified electrician in accordance with  
local codes and ordinances. In the absence of local  
codesorordinances,thesupplyshouldbeinstalled  
in accordance with the National Electric Code  
ANSI/NFPA No. 70, current issue, or Canadian  
Electric Code C22.1 Part 1.  
The Thermador® Outdoor Cooktop uses an  
electronic ignition system that requires a 120  
VAC, 15A, 60 Hz power supply. A properly  
groundedduplexoutletmustbeprovidedadjacent  
to the lower left rear corner of the unit. See  
Figure 2 (below).  
Figure 2  
WARNING  
Electrical Grounding Instructions  
This outdoor cooking gas appliance is  
equipped with a three-prong (grounding)  
plug for your protection against shock haz-  
ard and should be plugged directly into a  
properly grounded three-prong receptacle.  
Do not cut or remove the grounding prong  
from this plug.  
AVERTISSEMENT  
Instruction pour la mise  
a la terre electrique  
Cet appareil est muni d’une fiche a trots  
broches(misealaterre)afindevousproteger  
des chocs et doit etre branche dire~ement  
dans une prise de courant a trots broches  
adequatement mise a la tem. II ne faut pas  
couperouenleverlabrochedemisealatem  
de cette fiche.  
Cooktop Three-Prong Plug and Receptacle  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: UNPACKING AND PLACINGTHE UNIT  
LOCATINGYOUR  
OUTDOOR COOKTOP  
The following steps are necessary to  
convert for LP operation:  
Unpackandremoveallaccessoryitems,packingmaterials  
and product literature from the unit. Attach the gas  
pressure regulator to the end of the manifold as shown  
in Figure 3. Note the direction of gas flow. Connect one  
end of an approved outdoor gas supply hose to the  
regulator inlet. Connect the opposite end of the hose  
to the installer supplied shut-off valve. Refer to Section  
2 for gas requirements.  
1. Remove the grate,  
burner caps, ven–  
turis and burner  
bases.  
See Figure 4.  
FIGURE 3 NATURAL GAS HOOK-UP  
2. Remove the burn-  
er orifices. Use a  
7mm hex socket  
on a 3" ratchet  
extension and  
apply a piece of  
foam tape to the  
socket to hold the  
orifice in the  
socket while re-  
moving.  
Regulator 5.0" W.C.  
1/2" NPT  
Close Nipple  
See Figure 5.  
Adapter 1/2" NPT  
3. Replace with the  
LPorificessupplied  
(number 115).  
Tighten until snug.  
See Figure 6.  
to 3/8" flare fitting  
Threading compound  
must be resistant to  
L.P. gas  
Installer supplied  
shut-off Valve must  
be easily accessible  
Gas Hose  
(not supplied)  
4. Reassemble the  
burner bases and  
venturis. Reinstall  
burner caps and  
grate.  
CONVERSION FROM NATURAL  
GASTO LP (LIQUID PROPANE)  
Model SB2B is manufactured at the factory for use with  
natural gas, and as such requires conversion for use  
with an LP gas supply. The conversion should be done  
byaqualifiedtechnicianoryourgassupplier. Allorifices  
required for conversion are provided with the unit.  
Steps continue on  
next page  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: UNPACKING AND PLACINGTHE UNIT  
FIGU
FIGU
5. The bypass jet must be turned clockwise with a  
smallflat-bladedscrewdriveruntilfullyseatedtoset  
properlowflowrate. SeeFigures7and8, above.  
6. The cooktop is supplied with a pressure regulator  
that is packed with the unit. The regulator is set  
for natural gas. For use with propane, it must be  
converted. The regulator will be located on the  
left rear bottom of the unit. Using a flat blade  
screwdriver, remove the cap on the top of the  
regulator and turn the cap over so that the letters  
LP are exposed. Make sure the spring in the  
regulator remains in position. Reattach the cap to  
the regulator. See Figure 9, right.  
FIGURE 9  
Steps continue on next page  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: UNPACKING AND PLACING THE UNIT  
7. If the cooktop will be used with an LP cylinder,  
follow these steps:  
A. The Model LPHose is available at your  
Thermador dealer.  
B. This assembly can also be purchased locally  
providing it meets the following specifications:  
©
Bottom of  
unit  
Hose length to be 24".  
Regulator must be a high pressure, high volume  
unit capable of supplying adequate gas flow  
based on the input rating of the unit (refer to  
Gas Consumption in Section 2).  
C
t
t
r
Regulator Adapter  
The inlet connector on the LP regulator must  
be compatible with the LP cylinder valve.  
The hose and regulator assembly must be AGA  
certified for use with LP gas in an outdoor  
application.  
Collar  
C. Install a 1/2" NPT coupling at the end of the  
manifold located at the left rear bottom of the  
cooktop. Use a pipe sealant approved for use  
with LP gases on all threads.  
D. Attach gas regulator hose assembly to the  
coupling as shown in Figure 10, right.  
E. Connect the gas regulator assembly to the LP  
tank valve.  
F. Turn on the gas supply but do not attempt to  
light any burner. Check the unit for leaks per  
the instructions in Section 6.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6:TEST AND ADJUSTMENT  
GAS AND ELECTRICAL HOOK-UP  
With the unit inside of the enclosure, connect the  
gas supply hose to the manual shut-off valve and  
open valve. Check the connection points at the  
shut-off valve for any leaks and repair prior to  
installation of the unit. See Figures 11 and 12.  
Connect the power supply cord to the electrical  
supply outlet.  
CHECKING FOR LEAKS  
All points of connection to the gas supply should be  
checked for leaks at time of installation or anytime  
you smell gas. It is also advisable to recheck them  
periodically. Follow the steps outlined below:  
Bottom of Unit  
s  
Tank  
Valve  
A. Makeasoapsolutionofonepartliquiddetergent  
and one part water.  
B. Makesureallcontrolsareinthe"OFF"position.  
Turn on the gas supply to the unit. Use a spray  
bottle, brush or rag to apply the solution to all  
fittingsandpointsofconnectionfromthesupply  
stub out up to and including the inlet to the  
manifold. See Figures 11 and 12. Bubbles will  
form where a leak exists.  
Regulator  
Assembly  
LP Tank  
C. If a leak is present, shut off the gas at the supply.  
Tighten any leaking fittings, turn on the gas and  
recheck.  
Leak Test Points  
Figure 12 Leak Test Points – Plumbed Gas Supply  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6:TEST AND ADJUSTMENT  
INSTALLER CHECKLIST ꢀ  
INSTALLATION  
GAS SUPPLY  
— Appliance is connected to the proper type of  
gas supply.  
— Placement of unit.  
— Specified clearances maintained to combustible  
or noncombustible surfaces as applicable.  
— The burner box area is free of any packing  
materials and that the burners are properly  
located and installed.  
— Manual gas shut off valve is installed in an  
accessible location (with unit installed in  
enclosure for built-in installations).  
— Burner caps properly positioned and seated on  
burner bases.  
— Unit tested and free from gas leaks.  
— Gas supply pressure does not exceed 14" W.C.  
ELECTRICAL  
— Properly grounded receptacle is present for  
unit.  
— If the unit is to be used with propane gas, verify  
that the LP gas supply has its own high pressure  
regulator.  
WARNING: Remove the stainless steel burner cover before attempting to  
light the appliance. Failure to remove the cover could allow gas to accumulate  
which could cause an explosion.  
IFYOU SMELL GAS, DO NOT ATTEMPTTO LIGHT ANY BURNERS.  
BURNER AIRADJUSTMENT  
LIGHTING INSTRUCTION  
For Electronic Ignition:  
All burners are adjusted for proper flame  
characteristics at time of assembly.  
1. Make sure that all knobs are turned to the OFF  
position.  
Allburnersshouldexhibitflameswhichareblueand  
stable, with no yellow-tipping, lifting or excessive  
noise when operating on either natural or LP gases.  
2. Turn the knob to LITE position and immediately  
press the ignition switch. The burner will light  
within 4-10 seconds.  
If any of the flame characteristics noted above are  
observed, check the burner for dirt or residue in  
the ports, spider webs, etc., and clean or repair as  
necessary.  
3. Adjust control knob to the desired flame setting.  
For Manual Ignition:  
1. Check that the burner caps are in correct  
position, shown on Page 13.  
2. Turn control knob to the “LITE” position.  
3. Place the lighted match on the burner cap ports.  
4. Adjustcontrolknobtothedesiredflamesetting.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: USING YOUR OUTDOOR COOKTOP  
GENERAL BURNER INFORMATION  
Porcelain  
Enamel Cap  
Each burner is rated at 15,000 BTU on High.  
Choose a pan base to fit the flame size. The  
flameshouldneverextendbeyondthebaseof  
the pan.  
BURNER CAP  
Neverturnonaburnerwithoutremovingthe  
cover.  
Ports  
TAB A  
When not in use, place the stainless steel  
cover over the grate.  
Igniter  
USING THE BURNERS  
NOTCH B  
1. Remove the burner cover.  
FIGURE 13 – Burner Base  
2. Check that the burner caps are in the correct  
position. Tab A on the cap fits notch B on the  
base.  
3. Put grate in position.  
4. Follow Lighting Instructions on Page 12.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 8: CARE AND CLEANING  
PART and MATERIAL  
SUGGESTED CARE  
The quality of this material resists most stains and pitting, providing  
the surface is kept clean and protected with a stainless steel polish.  
Nonabrasive Cleaners: detergent and water, Fantastik®, 409®, vinegar.  
Mild abrasive Cleaners: liquid Kleen King®  
Exterior Finish/Cover  
Stainless Steel  
Stainless Steel Polish: Stainless Steel Magic®  
Grates  
Porcelain Enamel  
on Cast Iron  
• When removing the grates, care should be taken in lifting them. Be  
sure to place the grate on a protected surface.  
NOTE:Grateswilldevelopbilstersandchipsintheporcelainwithusedue  
to the extreme operating temperatures  
Hotsudsywaterandmildabrasivecleaners:Bon-ami®,SoftScrub®.  
For stubborn stains: a soap fllled steel wool pad.  
• Wash, rinse and dry. The occasional use of mild abrasive cleaners or  
steel wool soap-filled pad is okay. Abrasive cleaners, used vlgorously  
ortoooften, caneventuallyharmtheenamel. Applywithadampsponge,  
rinse thoroughly and dry.  
Burner Ports and Caps  
Aluminum/Porcelain  
Make certain that burners are turned OFF before cleaning.  
Ports Clear ports of any soil with a Wire, straightened paper clip  
or needle. Wash in hot sudsy water. Rinse and dry.  
Caps Wash in hot sudsy water. Rinse and dry. For hard-to-remove soil,  
use powdered cleaners such as Ajax®, Bon-ami®, Comet®.  
Hot sudsy water.  
Control Knobs, Bezels  
Plastic/Chrome  
• Pull knobs straight forward. Wash, do not soak. Rinse, dry and replace.  
Make certain the knobs are reinstalled In the proper location. Do not  
force knobs onto wrong control.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 9: SERVICE  
Troubleshooting  
Before Phoning for Service  
Power Failure - In the event of a power failure, the Thermador® Outdoor Cooktop may still be used by lighting  
the burners with a match.  
If Burners Fail to Ignite - If the burners fail to ignite  
verify that the unit is connected to a properly  
grounded duplex outlet. If electricity is present,  
look for spark to jump from the spark ignitor to  
the burner when the ignition switch is depressed  
and held. Make sure that the spark ignitors and  
burners are clean and dry. Verify that burner caps  
are in the correct position on the burner bases.  
Service Information  
The data rating label shows the model and serial  
numberforyourcooktop..Italsogivesinformation  
regarding burner rating and installation  
requirements.. The data rating label is located on  
the underside of the unit. For handy reference,  
copy the information below from the data rating  
label. Keep your invoice for warranty validation.  
__________________________________  
Model Number  
To Obtain Replacement Parts, order  
__________________________________  
Serial Number  
from the dealer where the unit was purchased  
or dial the telephone number listed below.  
__________________________________  
Date of Purchase  
HOW TO OBTAIN SERVICE  
__________________________________  
For authorized service or parts information, phone  
Dealer’s Name  
800/735-4328. We want you to remain a satisfied  
customer. If a problem does come up that cannot be  
__________________________________  
resolved to your satisfaction, please let us know.  
Dealer’s Phone Number  
Write: Thermador® Customer Call Center, 5551  
McFadden Avenue, Huntington Beach CA 92649 or  
__________________________________  
phone 800/735-4328. Please provide us with the Model  
Service Center’s Name  
Number, Serial Number and Date of Original Purchase/  
Installation.  
__________________________________  
Service Center’s Phone Number  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 10: WARRANTY  
Warranty  
This warranty applies to appliances used in residential  
application; it does not cover their use in commercial  
installations.  
Full One-YearWarranty  
Covers one year from the date of installation or date of  
occupancy for a new previously unoccupied dwelling.  
Save your dated receipt or other evidence of the  
installation/occupancy date.  
This warranty is for products purchased and retained  
in the 50 states of the U.S.A., the District of Columbia  
andCanada.Shouldtheappliancebesoldbytheoriginal  
purchaser during the warranty period, the new owner  
continues to be protected until the expiration date of  
theoriginalpurchaser’swarrantyperiod. Thewarranty  
applies even if you should move.  
Thermador® Will Pay For:  
All repair labor and replacement parts found to be  
defective due to materials and workmanship. Service  
must be provided by a Factory Authorized Service  
Agency during normal working hours. For a Service  
Agency nearest you, please call 800/735-4328.  
Thermador Will Not Pay For:  
THERMADOR DOES NOT ASSUME ANY  
RESPONSIBILITY FOR INCIDENTAL OR  
CONSEQUENTIAL DAMAGES. Some states do  
not allow the exclusion or limitation of incidental or  
consequential damages, so the above limitation or  
exclusionmaynotapplytoyou.Thiswarrantygivesyou  
specific legal rights and you may also have other rights  
which may vary from state to state or province to  
province.  
1. Service by an unauthorized agency. Damage or  
repairsduetoservicebyanunauthorizedagencyor  
the use of unauthorized parts.  
2. Service visits to:  
• Teach you how to use the appliance.  
• Correct the installation. You are responsible for  
providing electrical wiring and other connecting  
facilities.  
• Reset circuit breakers or replace home fuses.  
3. Damage caused from accident, alteration, misuse,  
abuse, improper installation or installation not in  
accordance with local electrical codes or plumbing  
codes, or improper storage of the appliance.  
4. Repairs due to other than normal home use.  
5. Any service visits and labor costs during the limited  
warranty.  
6. Travel fees and associated charges incurred when  
the product is installed in a location with limited or  
restrictedaccess,(i.e.,airplaneflights,ferrycharges,  
isolated geographic regions).  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to  
making counter opening. Consult with a heating and ventilating engineer for your specific ventilation requirements. For the  
most detailed information, refer to installation instructions accompanying product or write Thermador indicating the model  
number.  
Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada.  
Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your  
local Canadian distributor or dealer. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649.  
For the most up to date critical installation dimensions by fax, use your fax handset  
and call 702/833-3600. Use code #8030.  
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328  
ECO14028 • 08-04-638B • © BSH Home Appliances Corp. • Litho U. S. A. 4/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technika Portable DVD Player DPDVD7 User Manual
Timex Heart Rate Monitor M515 User Manual
Toastmaster Oven 18BCAN User Manual
Toshiba Computer Drive SD M1912 User Manual
TP Link Switch TL SL3428 User Manual
Tricity Bendix Cooktop SG211X User Manual
Troy Bilt Lawn Mower TB370XP User Manual
UNICOM Electric Switch SmartGST 2402 User Manual
Vulcan Hart Tiller ML 114950 User Manual
Weed Eater Blower 952711855 User Manual