Notice d’utilisation
Instruction manual
TPRO4300
Download from Www.Somanuals.com. All Manuals Search And Download.
BALANCE MECANIQUE MEDICALE
AFFICHAGE A HAUTEUR DE TAILLE
Vue de la face avant
Vue de la face arrière
Cadran
Molette
de réglage
Aiguille
Colonne
Indicateur
de niveau
Capot
de colonne
Plateau
Pieds réglables
Roues
CONTENU DE L’EMBALLAGE
•
•
•
•
•
•
•
Partie supérieure avec cadran et colonne.
Capot de colonne.
Base avec plateforme et pieds réglables.
3 vis M5 x 10 (dont 1 vis de rechange).
1 clé Allen M4.
1 tournevis.
Notice et manuel de montage.
PROCEDURE ET INSTRUCTION
DE MONTAGE
1. Insérer la colonne dans l’orifice du capot de colonne
et relever temporairement le capot afin de faciliter le montage.
Colonnes
Capôt de
colonne
Crochet
2
Download from Www.Somanuals.com. All Manuals Search And Download.
BALANCE MECANIQUE MEDICALE
AFFICHAGE A HAUTEUR DE TAILLE
2. Insérer la colonne dans l’orifice pratiqué dans la base,
en prenant soin de tenir le crochet avec votre main.
Important : pour garantir le bon fonctionnement
de la balance, veiller à ce que la colonne soit
complètement insérée dans la base. La colonne
est correctement insérée lorsque le repère rouge
(sur la colonne) coïncide avec le bord du collet
de la base.
3. A l’aide d’un tournevis, et en vous aidant de votre
main, fixer le crochet dans l’orifice de la plaque de
racordement. Vous pouvez visser la vis en acier
située sous la base (elle sera retirée à l’étape
suivante) de manière à rapprocher la longue plaque
de raccordement du crochet, pour faciliter l’accrochage.
Crochet
Plaque de
raccordement
Outil de montage
en métal
4. A l’aide de la clé Allen, retirer du petit orifice (situé
dans la partie inférieure de la base) l’outil de montage
en métal préinstallé afin de libérer la plaque de
raccordement et de la faire redescendre en place.
Crochet
Plaque de
raccordement
5. A l’aide du tournevis, fixer la colonne à la base en
vissant fortement les deux vis à la gauche et à la
droite de la colonne.
Vis
3
Download from Www.Somanuals.com. All Manuals Search And Download.
BALANCE MECANIQUE MEDICALE
AFFICHAGE A HAUTEUR DE TAILLE
6. Rabaisser le capot de colonne en appuyant vers
la base jusqu’à ce qu’il s’enclenche de part et d’autre.
Initialisation
• Avant la première utilisation de la balance, ou lorsqu’elle a été déplacée, il est nécessaire de régler la
mise à zéro et l’équilibre.
1. Ne pas monter sur la balance et/ou enlever tout poids du plateau.
2. Placer la balance sur une surface ferme et plane. Agir sur les pieds réglables pour ajuster le niveau de la
balance jusqu’à ce que la bulle contenue dans l’indicateur de niveau apparaisse au centre du cercle gravé.
Indicateur
de niveau
Cercle
Bulle
3. Régler l’aiguille sur « Zéro » à l’aide de la molette
de réglage
Molette
de réglage
Fonctionnement
1. Monter sur le plateau et rester immobile durant la pesée.
2. Le poids s’affiche sur le cadran.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
BALANCE MECANIQUE MEDICALE
AFFICHAGE A HAUTEUR DE TAILLE
GARANTIE
Ce produit est garanti contre les défauts de matériaux et de fabrication. Pendant la période de garantie, de
tels défauts seront réparés gratuitement (la preuve d’achat devra être présentée en cas de réclamation
sous garantie). Cette garantie ne couvre pas les dommages résultant d’accidents, de mauvaise utilisation
ou de négligence. En cas de réclamation, contacter en premier lieu le magasin où vous avez effectué votre
achat.
SERVICE APRES-VENTE
Pour le service après-vente, contacter le service consommateur de Terraillon à l’adresse suivante :
After Sales Service : Terraillon France & Headquarters - B.P.73 -78403 Chatou Cedex-France
Service consommateurs : 0 826 88 1789
FOOK TIN TECHNOLOGIES LTD
4/F, Eastern Centre, 1065 King Road, HONG KONG
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL MEDICAL SCALE
Dear Customer,
Thank you for purchasing this product. We hope you will find it satisfactory. Please read these instructions carefully
to take full advantage of your product.
READ BEFORE USE
The Mechanical Medical Scale is designed and manufactured in a facility certified in the following Management
Systems : ISO 9001 Quality, ISO14001 Environment, OHSAS18001 Health and Safety.
This scale is manufactured to conform with the United States FDA Class I requirements for certification
as a Patient medical weighing device. Regulation 880.770. Establishment Registration N° 3005374248.
Applications
The mechanical medical scale’s intended use is for weighing patients for the purposes of monitoring, diagnosis
and medical treatment.
Précautions of use
This symbol indicates general precautions that should be taken when
using this product.
This symbol indicates the possibility of serious injury if the product
is mishandled or instructions are ignored.
WARNING
This symbol indicates the possibility of physical injury or equipment
damage if instructions are ignored.
CAUTION
WARNING
s Use the product on a firm and flat surface.
s Clean after use with a lightly dampened cloth without allowing any water to get into the device. Do not use solvents
or immerse the product in water.
s Avoid excessive impact or vibration to the unit, such as dropping the product onto the floor.
s Do not jump on the weighing platform.
CAUTION
s Do not disassemble the scale as incorrect handling may cause injury.
MAINTENANCE
s The product has been manufactured with precision. The user should not disassemble the product on its own.
PRODUCT SPECIFICATION
s Weighing function
s Level indicator and adjusting feet
s Large dial : 8’’
s Capacity: 400lb / 180 kg
s Graduation: 1lb / 0.5 kg
6
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL MEDICAL SCALE
Front view
Back view
Dial
Pointer
Adjusting
scroll
Pillar
Level indicator
Pillar cover
Platform
Adjusting feet
Wheels
ITEMS INCLUDED IN THE PACKAGE
•
•
•
•
•
•
•
Top part with dial and pillar.
Pillar cover.
Base part with platform and adjusting feet.
3 pcs M5 x 10 screws (1 pc screw as spare part).
1 M4 Allen Key.
1 screw driver.
Instruction and assembly manual.
PROCEDURES AND INSTRUCTIONS
FOR PRODUCTS ASSEMBLY
1. Insert the pillar into the hole of the pillar cover
and move the cover temporarily up for easier assembly.
Pillar
Pillar cover
Pothook
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL MEDICAL SCALE
2. Insert the pillar into the hole at the base, while holding
the pothook with your hand.
Important: Ensure pillar is completely seated onto
base otherwise the scale will not operate correctly.
When the red indicator line (located on the pillar)
meets the edge of the collar on the base, the pillar
will be properly seated in the base of the scale.
3. Use screw driver as well as your hand to hook the
pothook into the hole of the long arm connecting plate.
The steel screw on the base (which will be removed
in the next step) can be adjusted inward to move the
long arm connecting plate up towards the pothook
and make the connection between the two points easier.
Pothook
Long arm
connecting plate
Pre-set assembly
steel screw
4. Using Allen key to remove the pre-set assembly
steel screw out from the small hole (located in the bottom
part of the base) to release long arm connecting
plate down to its place.
Pothook
Long arm
connecting plate
5. Using screw driver to fix the pillar to the base by
screwing in tightly the 2 pcs of screws at the left and
right side of the pillar.
Screws
8
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL MEDICAL SCALE
6. Move the pillar cover down and push it onto the
base until it clicks on both sides
PRODUCT USAGE
Initialisation
• Before you use the scale for the first time or when the scale has been moved to another place, the zeropoint
and balance of the scale must be set.
1. Do not step on the scale or/and remove all weight from the platform.
2. Place the scale on a hard and flat surface. Use the adjusting feet to adjust the balance until the bubble
inside the level indicator is located in the middle of the drawn circle.
Level
indicator
Circle
Bubble
3. Adjust the pointer to “Zero” using adjusting scroll.
Adjusting
scroll
Operation
1. Step on the platform and stand still during the weighing operation process.
2. The weight will be shown on the dial.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL MEDICAL SCALE
GUARANTEE
This product is guaranteed against defects in materials or manufacturing. During the guarantee period, any
such defects will be repaired free of charge (proof of purchase must be shown in the case of a complaint
under guarantee). The guarantee does not cover damage resulting from improper use or negligence. In the
event of a claim, first contact the shop where you purchased the product.
AFTER SALES SERVICE
For calibration and after sales services, please contact Terraillon consumer service at the following
address:
After Sales Service : Terraillon France & Headquarters - B.P.73 -78403 Chatou Cedex-France
Service consommateurs : 0 826 88 1789
FOOK TIN TECHNOLOGIES LTD
4/F, Eastern Centre, 1065 King Road, HONG KONG
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Terraillon France & Headquarters
B.P. 73 - 78403 Chatou Cedex - France
Service consommateurs : 0 826 88 1789
Service Après Vente :
Terraillon chez MGF logistique
ZI d’Epluches - Rue des Préaux
95310 St Ouen - l’Aumône
Hanson (UK) Ltd
81a Marlowes - Hemel Hempstead
Hertfordshire, HP1 1LF - UK
Terraillon Deutschland GmbH
Gehlengraben 2
22415 Hamburg - Deutschland
Terraillon SpA
Viale Sarca 45
Milano - Italy
Tel: +39 (0)2 66114199
Terraillon Asia Pacific Ltd
4/F, Eastern Centre
1065 King’s Road
Quarry Bay - Hong Kong
Tel: +852 (0)2960 7288
Terraillon Corp
1860 Renaissance Blvd
Sturtevant, WI 53177 - USA
Tel: +1-866-696-6066
Download from Www.Somanuals.com. All Manuals Search And Download.
|