Telular Telephone SX6P 300G User Manual

P
HONECELL® SX6P GSM  
• Fixed Wireless Phone  
850/1800/1900 MHZ GSM (TRI BAND) AND  
900/1800/1900 MHZ GSM (TRI BAND) MODELS  
USER MANUAL  
12/15/04  
Part Number 56031701  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SX6P MENU STRUCTURE  
Phonebook  
Service Numbers  
View Names  
Add Name  
Menu  
Settings  
Call Log  
All Calls  
Missed Calls  
Received Calls  
Dialed Numbers  
Clear Logs  
Call Time  
Messages  
Received Messages  
Saved Messages  
Create Message  
Message Settings  
Voicemail  
GPRS Info  
Info Message  
Call Divert  
All Calls  
When Busy  
No Answer  
Not Found  
Clock  
Cancel All Diverts  
Set Alarm  
Clock Settings  
Set Time  
Set Date  
Set Time Zone  
Settings  
Phone Settings  
Audio Settings  
Call Settings  
Data Settings*  
Dial Settings  
Network Settings  
Security Settings  
Restore Defaults  
Service Settings**  
* Not available on SX6P-200G  
** Requires password  
Phonecell® SX6P GSM  
ii  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
Phonecell® SX6P GSM Desktop Phone Spike Antenna  
Power Supply  
AC Power Cord  
Before installing your Phonecell® SX6P, carefully remove the contents from the shipping carton  
and check for evidence of shipping damage. If damage is found, contact your Authorized  
Telular Distributor or shipping agent immediately.  
SAFE OPERATION INSTRUCTIONS  
IMPORTANT! Before installing or operating this product, read the SAFETY INFORMATION  
section of this manual.  
Install unit indoors.  
Install unit on hard, flat surface for proper ventilation.  
Do not expose unit to rain or moisture.  
Do not place unit on or close to sources of heat  
PLEASE SEE THE IMPORTANT NOTICES SECTION OF THIS MANUAL FOR  
IMPORTANT INFORMATION ON USE, WARRANTY AND INDEMNIFICATION  
IMPORTANT NOTICES  
TERMS AND CONDITIONS FOR USE OF PHONECELL® PRODUCTS ("Product")  
These Terms and Conditions are a legal contract between you and Telular Corporation for the title to and use of the Product.  
BY RETAINING AND USING THE PRODUCT AFTER RECEIPT OF IT, YOU AGREE TO THE TERMS AND CONDITIONS  
INCLUDING WARRANTY DISCLAIMERS, LIMITATIONS OF LIABILITY AND INDEMNIFICATION PROVISIONS BELOW. IF  
YOU DO NOT AGREE TO THE TERMS AND CONDITIONS, DO NOT USE THE PRODUCT AND IMMEDIATELY RETURN  
THE UNUSED PRODUCT FOR A COMPLETE REFUND. You agree to accept sole responsibility for any misuse of the Product  
by you; and, in addition, any negligent or illegal act or omission of your or your agents, contractors, servants, employees, or  
other users of the Product so long as the Product was obtained from you, in the use and operation of the Product.  
INDEMNIFICATION OF TELULAR CORPORATION ("TELULAR")  
YOU SHALL INDEMNIFY, DEFEND AND HOLD HARMLESS TELULAR FOR ANY OF THE COST, INCLUDING REASON-  
ABLE ATTORNEYS' FEES, AND FROM CLAIMS ARISING OUT OF YOU, YOUR CLIENTS' OR OTHER THIRD PARTIES'  
USE OR OPERATION OF THE PRODUCT: (i) FOR MISUSE OR IN A MANNER NOT CONTEMPLATED BY YOU AND  
TELULAR OR INCONSISTENT WITH THE PROVISIONS OF THIS MANUAL; (ii) IN AN ILLEGAL MANNER OR AGAINST  
PUBLIC POLICY; (iii) IN A MANNER SPECIFICALLY UNAUTHORIZED IN THIS MANUAL; (iv) IN A MANNER HARMFUL  
OR DANGEROUS TO THIRD PARTIES; (v) FROM CLAIMS BY ANYONE RESPECTING PROBLEMS, ERRORS OR MIS-  
TAKES OF THE PRODUCT; OR (vi) COMBINATION OF THE PRODUCT WITH MATERIAL, MODIFICATION OF THE  
PRODUCT OR USE OF THE PRODUCT IN AN ENVIRONMENT NOT PROVIDED, OR PERMITTED, BY TELULAR IN WRIT-  
ING. THE PARTIES SHALL GIVE EACH OTHER PROMPT NOTICE OF ANY SUCH COST OR CLAIMS AND COOPER-  
ATE, EACH WITH THE OTHER, TO EFFECTUATE THIS INDEMNIFICATION, DEFENSE AND HOLD HARMLESS.  
TELULAR CORPORATION  
Corporate Headquarters  
647 North Lakeview Parkway  
Vernon Hills, Illinois 60061, USA  
Technical Support  
Tel: 847-247-9400 • Fax: 847-247-0021  
Part Number 56031701  
©2004 Telular Corporation, All Rights Reserved  
Phonecell® SX6P GSM  
iii  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
QUICK CONNECTION GUIDE .......................................................................................i  
SX6P MENU STRUCTURE............................................................................................ii  
CONTENTS...................................................................................................................iii  
SAFE OPERATION INSTRUCTIONS...........................................................................iii  
IMPORTANT NOTICES.................................................................................................iii  
SX6P SETUP..................................................................................................................1  
SIM Card Installation .................................................................................................1  
Battery Installation .....................................................................................................1  
Battery Operation.......................................................................................................2  
Location and Setup....................................................................................................2  
Connect the Handset.................................................................................................2  
Wall-Mounting ............................................................................................................3  
Connect the SX6P to AC Power................................................................................4  
GETTING TO KNOW YOUR SX6P................................................................................5  
Function Keys............................................................................................................5  
LCD Screen Icons......................................................................................................6  
Service Indication ......................................................................................................6  
CALL FUNCTIONS ........................................................................................................7  
Making Calls ..............................................................................................................7  
Receiving Calls..........................................................................................................7  
Ending Calls...............................................................................................................7  
In-Call Functions........................................................................................................7  
SX6P BASIC FEATURES ..............................................................................................8  
Date and Time Settings .............................................................................................8  
Audio Settings............................................................................................................8  
Adjust Alert Tones......................................................................................................9  
Speakerphone............................................................................................................9  
Phonebook.................................................................................................................9  
Speed Dialing...........................................................................................................11  
Change the Display Screen Contrast ......................................................................11  
ChangeBacklight Options.........................................................................................11  
SX6P ADDITIONAL FEATURES .................................................................................12  
Call Logs..................................................................................................................12  
Alarm Settings..........................................................................................................12  
Language Selection.................................................................................................13  
Personalization Options...........................................................................................13  
Call Settings.............................................................................................................14  
Network Settings......................................................................................................15  
SIM PIN Setup.........................................................................................................16  
Handset Call Barring................................................................................................17  
Restricted Dialing.....................................................................................................18  
Deskphone Lock......................................................................................................18  
Closed User Groups (CUG).....................................................................................19  
Restore Factory Defaults.........................................................................................19  
Phonecell® SX6P GSM  
iv  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUPPLEMENTARY SERVICES (NETWORK DEPENDENT) .....................................20  
In-Call Options.........................................................................................................20  
Call Divert (Forwarding)...........................................................................................20  
Call Waiting..............................................................................................................21  
Multiparty Calling .....................................................................................................21  
Caller ID Settings.....................................................................................................21  
Blocking Your Number (CLIR) .................................................................................21  
Voicemail..................................................................................................................22  
Short Message Service (SMS) ................................................................................22  
Information Messages .............................................................................................24  
Network Call Barring................................................................................................25  
DATA FEATURES ........................................................................................................26  
Connect SX6P to a Computer .................................................................................26  
Configure PC for Circuit Switched Data ..................................................................26  
Automatic Baud Rate Fall Back Control..................................................................26  
Digital Fax Setup .....................................................................................................27  
GPRS (Packet Data) Connections...........................................................................27  
SX6P TROUBLESHOOTING.......................................................................................28  
CONFORMANCE STATEMENTS................................................................................29  
SAFETY INFORMATION .............................................................................................29  
WARRANTY.................................................................................................................32  
APPENDIX A: PC SERIAL PORT SETUP FOR CS FAX AND DATA........................34  
Phonecell® SX6P GSM  
v
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SX6P SETUP  
SIM Card Installation  
The SX6P requires a Subscriber Identification Module (SIM) for normal operation. The service  
provider supplies the SIM card, which carries the account information needed to operate the  
SX6P. The SIM compartment is on the back of the SX6P.  
NOTE: If you don’t have a SIM card, contact your network service provider.  
1. Make sure the unit is off and the power supply disconnected before removing or installing a  
SIM Card.  
2. Remove the SIM compartment cover by removing the screw.  
3. Open the SIM compartment holder.  
4. Line up the SIM card with the arrow on the SIM card holder - see Figure 1.  
5. Gently insert the SIM card in the slot of the SIM card holder.  
6. Close the SIM card holder.  
NOTE: Do not force the SIM card holder shut. Make sure the SIM card is aligned properly  
with the directional arrow on the holder.  
7. Reattach the SIM compartment cover with the screw.  
SIM Compartment Cover  
Cover Screw  
SIM Card  
Holder  
SIM Card  
Figure 1 - SIM card installation.  
Install Batteries (optional)  
1. Remove the battery access door screw located on the bottom of the unit - see Figure 2.  
2. Press the battery access door tabs and remove the battery access door.  
3. Install the Telular 3.6V rechargeable battery pack into the battery pack area.  
4. Reinstall the battery access door using the screw - see Figure 3.  
WARNING!  
Do not use batteries other than the included Telular battery pack with the SX6P.  
Using any other batteries may result in fire and/or other damage to the unit.  
!
Battery Access Door  
Battery Access  
Door Screw  
Battery Pack Area  
Battery Access Door Tabs  
Figure 2 – Battery access door.  
Phonecell® SX6P GSM  
Figure 3 - Battery installation.  
1
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery Operation  
The SX6P will recharge its battery pack when connected to AC power. If AC power is interrupted,  
the SX6P will continue to operate, using power from the battery. (Standby and talk-times will vary  
based upon phone usage during power interruption.)  
Location and Setup  
The SX6P comes with a standard spike antenna (TNC).  
NOTE: The supplied antenna will support either 850/1900 MHz or 900/1800 MHz frequincies,  
as specified by your wirless service network provider.  
1. Attach and finger-tighten the antenna - see Figure 4. Do not over-tighten the antenna.  
2. Select a location that is above ground and as close to windows (or exterior walls) as possible  
to get the best signal - see Figure 5.  
Figure 5 - SX6P location.  
Figure 4 - Attach the antenna.  
Connect the Handset  
Before you can use the SX6P, you must connect the handset cable.  
1. Connect the handset cable to the phone jack - see Figure 6.  
2. Connect the handset cable to the handset - see Figure 6.  
Phone jack  
Handset cable  
Handset  
Figure 6– SX6P handset connection.  
Phonecell® SX6P GSM  
2
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wall-Mounting  
1. Remove the mounting clip from the cradle and re-insert it with the tab pointing up - see  
Figures 7 and 8.  
Mounting Clip in  
Cradle (tab up)  
Remove  
Mounting Clip  
from the Cradle  
(tab down)  
Insert  
Mounting  
Clip into  
the Cradle  
(tab up)  
Figure 8 – Handset mounting clip for wall-mount.  
Figure 7 – Handset mounting clip assembly.  
2. Mark two hole locations 83 mm (3-1/4 inches) vertically apart and drill two holes into the wall.  
3. Install the screws (not supplied) into the wall, leaving a gap of approximately 3 mm  
(1/8 inches) between the screw head and the wall.  
6. Align the mounting holes with the screws and mount the SX6P onto the screws - see Figures  
9 and 10.  
Mounting  
Holes  
Figure 10 – Mount the SX6P onto the screws.  
Figure 9 – SX6P mounting hooks.  
Phonecell® SX6P GSM  
3
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect the SX6P to AC Power  
1. Connect the barrel connector of the power supply to the AC power input on the rear panel of  
the SX6P - see Figure 11.  
2. Plug the AC power cord into the power supply.  
3. Plug the AC power cord into the wall socket.  
4. Press and hold the ON/OFF button for 3 to 5 seconds.  
5. Check the cellular signal strength and move the unit until the best signal possible is  
achieved - see the Service Indication section of this manual.  
AC Power  
Input  
Barrel  
Connector  
Wall Socket  
AC Power Cord  
Power Supply  
Figure 11 – SX6P AC power connection.  
Phonecell® SX6P GSM  
4
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GETTING TO KNOW YOUR SX6P  
Function Keys  
Operation of the SX6P is accomplished through the function keys on the keypad of the unit - see  
Figure 12.  
LCD Screen - Displays  
icons, information, and  
menu options necessary  
Power - Used to power unit On  
and Off.  
to operate the SX6P.  
Volume - Controls the speaker  
volume level for the handset and  
the speakerphone when the SX6P  
is off-hook.  
LCD Soft Keys - Provide  
access to the SX6P menu  
options and features.  
Redial - Dials the last number  
called from the SX6P.  
Hold - Used to put the  
active call on hold or to  
reactivate an on-hold call.  
Flash - Allows answering of call  
waiting, connecting multiparty calls,  
and putting an active call on hold to  
make another call. Also can be  
used to skip Dial Delay time (quick  
dial).  
Mute - Prevents the party on the  
other end of a call from hearing any  
sound from the SX6P.  
Speakerphone - Engages the  
speakerphone feature.  
Figure 12 – SX6P keypad and function keys.  
Phonecell® SX5 GSM  
5
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LCD Screen Icons  
Icons displayed on the LCD screen indicate the features in use, the status of the phone, signal  
strength and battery status - see Figure 13.  
Speaker - Indicates speaker  
phone is activated.  
Call - Indicates that the hand-  
set is off-hook.  
Message - Displays when  
a new text or voicemail  
message has been received.  
Battery - Indicates the level of  
battery power. The more bars,  
the more power.  
Alarm - Indicates that  
the alarm feature has  
been set.  
Received Signal  
Clock - Displays the  
current time.  
Strength - Indicates the  
strength of the current  
signal. The more bars,  
the stronger the signal.  
LCD Soft Key Labels - Provide access to features within  
the sub-menus of the SX6P. Labels change according to  
the selected sub-menu.  
Figure 13 – SX6P LCD screen icons.  
Service Indication  
Full Service  
When powered on, the SX6P will display a wakeup banner (the 300G models LCD screen and  
keypad backlight will also light). After a few seconds, the greeting and mobile carrier will display.  
If service is available, the antenna icon will display indicator bars. The number and height of the  
indicator bars increases as the signal grows stronger (the more bars, the better the signal).  
No Service  
When no service is available, the antenna icon will not display any bars. Contact your service  
provider to verify cellular service is activated. No calls can be made in this condition.  
Limited Service  
If there is a signal, but full service with the system is blocked, only emergency calls will be  
allowed. Contact your service provider for more information.  
Network Registration  
If the home network is unavailable, but there is another network available (either another fre-  
quency or system), the SX6P will attempt to register to that system. If there is more than one  
system, a list of available systems will display.  
1. Use the arrow keys to highlight a network from the list.  
2. Press the SELECT key. If the selected network cannot be accessed, the list of available net-  
works will be updated and a different network must be selected.  
Phonecell® SX6P GSM  
6
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CALL FUNCTIONS  
Making Calls  
1. Pick up the handset or press the SPEAKERPHONE key.  
The SX6P is now “off-hook.”  
2. Listen for dial tone.  
3. Dial the phone number. The dialed number will be displayed. The name will also be displayed  
if it is stored in the phonebook.  
Correct Dialing Errors  
To erase one digit, press the CLEAR key once.  
To erase all digits, press and hold down the CLEAR key until all digits are erased.  
To insert numbers, use the arrow keys.  
Redial the Last Telephone Number Dialed  
1. Pick up the handset or press the SPEAKERPHONE key. The SX6P is now “off-hook.”  
2. Press the REDIAL key.  
Receiving Calls  
When there is an incoming call, the SX6P rings, an incoming call notification displays the call  
type and Caller ID information (if available).  
1. Pick up the handset or press the SPEAKERPHONE key.  
2. Begin talking.  
NOTE: Press the REJECT key to refuse the call. The phone will stop ringing and the calling  
party will be disconnected.  
Receive a Call When Caller ID is Activated  
The Caller ID feature displays the caller’s number when the SX6P rings. If the caller’s name and  
number are stored together in the SX6P phonebook, the caller’s name and number will be dis-  
played. Contact your service provider to activate this feature.  
NOTE: If there are missed calls (calls not answered), “MISSED CALLS” will be displayed with  
the number of calls missed. See  
the Call Logs section of this manual for more information.  
Ending Calls  
Hang up the phone by either placing the handset back onto the SX6P cradle or press the SPEAK-  
ERPHONE key if using the speakerphone.  
In-Call Functions  
Mute a Call  
1. While in a call, press the MUTE key. A notification will display in the upper right corner of the  
LCD screen.  
2. Press the MUTE key again to un-mute the microphone.  
Place a Call on Hold  
1. While in a call, press the HOLD key.  
2. The display will change from Active to Held.  
3. To reactivate the call, press the HOLD key again.  
Adjust Volume  
1. While in a call, press the Volume keys to raise or lower the handset/speakerphone volume.  
Phonecell® SX6P GSM  
7
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SX6P BASIC FEATURES  
Date and Time Settings  
The SX6P allows customization of the date, time, time zone, and time format (12 or 24 hour).  
Set the Date  
1. Press the MENU key.  
2. Select Clock.  
3. Scroll to Set Date, then press the CHANGE key.  
4. Enter the desired date.  
5. Press the OK key.  
Change the Date Format  
1. Press the MENU key.  
2. Select Clock, then select Clock Settings.  
3. Scroll to Date Format. The current format will display.  
4. Press the CHANGE key.  
5. Select the desired date format.(D:M:Y, M:D:Y, or Y:M:D)  
6. Press the OK key.  
Set the Time  
1. Press the MENU key.  
2. Select Clock.  
3. Select Set Time.  
4. Enter the desired time.  
5. Press the OK key.  
Change the Time Format  
1. Press the MENU key.  
2. Select Clock, then select Clock Settings.  
3. Scroll to Time Format. The current format will display.  
4. Press the CHANGE key.  
5. Select the desired time format (12 hour or 24 hour).  
6. Press the OK key.  
Set the Time Zone  
1. Press the MENU key.  
2. Select Clock, then scroll to Set Time Zone.  
3. Press the CHANGE key. Use the two middle soft keys to scroll left or right on the graphic to  
highlight the time zone you are in.  
4. Press the far left soft key to select the highlighted time zone.  
Audio Settings  
Adjust Alert Volume (Ringer)  
1. Press the MENU key.  
2. Select Settings, then select Audio Settings.  
3. Select Alert Volume, then set the desired volume level using the arrow keys.  
Phonecell® SX6P GSM  
8
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjust Alert Tones (Ringer)  
Alert tones can be customized for different types of calls, such as voice or text.  
1. Press the MENU key.  
2. Select Settings, then select Audio Settings.  
3. Use the arrow keys to scroll through the alert types.  
4. Select the desired alert sound.(Voice call alert, SMS alert, Voicemail alert)  
NOTE: If No Alert is selected, no alert will sound.  
Turn On/Off the Keypad Tones  
1. Press the MENU key.  
2. Select Settings, then select Audio Settings.  
3. Select Keypad Tones.  
4. Select On or Off.  
Turn On/Off the Warning Tones  
1. Press the MENU key.  
2. Select Settings, then select Audio Settings.  
3. Select Warning Tones.  
4. Select On or Off.  
Speakerphone  
1. Press the SPEAKERPHONE key. A dial tone will be heard through the speaker and the  
Speaker icon will display.  
2. Enter a telephone number, press the REDIAL key or press the NAME key to find a number  
you have previously entered into the Phonebook - see the Phonebook section of this manual  
for details about how to enter a number.  
Speakerphone Microphone Adjustment  
You can adjust the microphone gain of the speakerphone from -5 to +5 using Spkr Phone Adj in  
the Audio Settings menu.  
1. Press the MENU key.  
2. Select Settings then Audio Settings.  
3. Select Spkr Phone Adj then the desired microphone gain using the arrow keys.  
Phonebook  
The SX6P has an Internal Phonebook capable of storing up to 250 telephone numbers with cor-  
responding names in the SIM card (SIM cards may have different memory capacities) and 18 in  
the phone memory.  
HINT: To dial a number from the Phonebook when off hook, press the NAME key, select the  
name, then press the DIAL key.  
NOTE: The Phonebook will not be accessible while the SIM Card is read when the SX6P is  
powered on. This process takes approximately 60 seconds.  
Adjust Phonebook Settings  
Entries can be saved to the SIM card or to the phone memory. When numbers are saved to the  
SIM card, they can be transferred by removing the SIM card and installing it in another GSM  
phone.  
1. Press the MENU key.  
2. Select Phonebook, then select Settings.  
3. Select Save Entries To. (SIM card, Choice or Phone memory).  
4. Select the desired location of the phonebook entries.  
Phonecell® SX6P GSM  
9
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keypad Buttons for Text Entry (Multitap)  
There are three or four letters (as well as a number) assigned to each key on the telephone  
keypad. During text entry, pressing a key displays the first letter, then cycles through the other  
letters. For example, if the number 3 is pressed, a “D” will appear. If it is pressed again, the “E”  
will appear, and if it is pressed three times, the “F” will appear. The cursor will move on to the  
next space after a brief pause, so the letter must be selected quickly.  
Enter a Hard Pause  
Hard pauses allow the SX6P to be used with automated phone systems used for pagers or auto-  
mated banking. When a number is programmed into the phonebook, a pause is entered by  
pressing and holding “#” for more than one second. The hard pause will be displayed as “P.”  
Use of Lower Case or Numbers  
The “ ” key can be used to switch change from upper case (ABC) to lower case (abc) or to num-  
*
bers (123). The current setting will display under the clock in the upper right corner of the LCD  
screen.  
Use Special Characters  
The “1” key can access several special characters (punctuation marks and symbols). To scroll  
through available special characters, press the “1” key repeatedly.  
Add a New Entry to the Phonebook  
1. Press the MENU key.  
2. Select Phonebook, then select Add Name.  
3. Enter a name by pressing the alphanumeric keys (maximum 16 characters).  
HINT: Use the “ ” key to switch between upper case, lower case and numbers. Use the “0”  
*
key to insert a space between entries. Use the “1” key to access special characters. To cor-  
rect errors in the name, press the CLEAR key.  
4. Press the OK key.  
5. Enter the desired telephone number (maximum of 20 digits).  
6. Press the OK key. You will be prompted to enter another number.  
7. Press the OK key to save the entry and return to the Phonebook menu. If you have additional  
numbers (up to 2 more) follow steps 5 through 7 for each number.  
Phonebook Entry Search  
1. Press the NAME key.  
2. Use the arrow keys to scroll through the entries or use the keypad to view all entries that  
begin with a specific letter.  
3. Press the SELECT key to view the phone number(s) listed for a highlighted entry.  
Edit or Delete an Entry  
1. Press the NAME key.  
2. Use the arrow keys to scroll through the entries, or use the keypad to view all entries that  
begin with a specific letter.  
3. Press the SELECT key to view the phone number(s) listed for an entry that is highlighted.  
4. Press the OPTIONS key and select the desired option. (Edit Name, Edit Number, Add  
Number, Add Name, Add to Speed Dial, Delete Number or Delete Entry).  
Phonecell® SX6P GSM  
10  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Speed Dialing  
Speed dialing permits one-touch dialing for up to 10 telephone numbers stored in the phone  
book. 0 through 9 on the keypad are used for speed dialing. You must press and hold the corre-  
sponding key for 2 seconds to use speed dial.  
Assign a Number to a Speed Dial Location  
1. Press the NAME key.  
2. Select the desired entry to add to the speed dial list.  
3. Press the OPTIONS key.  
4. Select Add to Speed Dial.  
5. Use the arrow keys to scroll to a location, then press the SELECT key.  
NOTE: If a location is already in use, the phone number that is stored there can be replaced  
with a new one.  
Dial a Speed Dial Location  
1. Pick up the handset or press the SPEAKERPHONE key.  
2. Press and hold the number (for 2 seconds) of the location containing the speed dial number  
to be called.  
3. The number is displayed and dials automatically.  
View the Speed Dial List  
1. Press the MENU key.  
2. Select Phonebook, then select Settings.  
3. Select Speed Dial List.  
Change the Display Screen Contrast  
1. Press the MENU key.  
2. Select Settings, then select Phone Settings.  
3. Select Screen Contrast.  
4. Use the arrow keys to adjust the display contrast.  
5. Press the OK key.  
Change Backlight Options (SX6P-300G Series Only)  
1. Press the MENU key.  
2. Select Settings, then select Phone Settings.  
3. Select Backlight, then choose the keypad lighting setting you prefer.  
ON: Display and keypad are lit whenever phone is in use.  
15 Seconds: Display and keypad light when phone is in use, then go dark after 15 seconds.  
Power Save: Display and keypad are never lit.  
Phonecell® SX6P GSM  
11  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SX6P ADDITIONAL FEATURES  
Call Logs  
The SX6P stores the telephone numbers of the last ten outgoing calls and the last ten incoming  
calls with the dates and times of the calls. These numbers are displayed and can be dialed  
directly from the call log.  
View the Call Log  
1. Press the MENU key.  
2. Select Call Log.  
3. Select the desired calls to view (All, Missed, Received,Dialed). Calls are denoted by the  
following icons:  
Dial a Number From the Call Log  
1. Press the MENU key.  
2. Select Call Log.  
3. Highlight the desired call to dial.  
4. Pick up the handset or press the SPEAKERPHONE key.  
5. A dial tone will sound, then the number will be dialed.  
NOTE: This feature will not work for unavailable or private calls (denoted as Withheld in the Log).  
Clear the Call Log  
1. Press the MENU key.  
2. Select Call Log, then select Clear Logs.  
3. Select Yes to clear the call log. Select No to return to the Call Log menu.  
Check the Last Call Time  
1. Press the MENU key.  
2. Select Call Log, then select Call Time.  
3. Select Last Call Time.  
Check Total Accumulated Air Time  
1. Press the MENU key.  
2. Select Call Log, then select Call Time.  
3. Select All Calls Time.  
GPRS Call Information  
1. Press the MENU key.  
2. Select Call Logs then GPRS Info.  
Alarm Settings  
The SX6P alarm feature can be used as an alarm clock. Alarm time and tone can be set for daily  
use or for one time only.  
Set Alarm Time and Tone  
1. Press the MENU key.  
2. Select Clock, then select Set Alarm.  
3. Select Set Time, then enter the desired alarm time.  
4. Press the OK key.  
5. Select Set Tone, then select the desired alarm tone.  
6. Press the OK key.  
5. Press the OK key.  
Phonecell® SX6P GSM  
12  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Alarm to Repeat Daily  
1. Press the MENU key.  
2. Select Clock, then select Set Alarm.  
3. Select Repeat Daily.  
Turn Alarm On/Off  
1. Press the MENU key.  
2. Select Clock, then select Set Alarm.  
3. Select Alarm Status.  
4. Select On or Off.  
5. Press the OK key.  
Language Selection  
The SX6P is capable of displaying menu items in several different languages.  
Select a Language  
1. Press the (MENU) key.  
2. Select Settings.  
3. Select Phone Settings.  
4. Select Set Language.  
5. Scroll through the list of desired languages.  
6. Highlight the desired language, then press the SELECT key.  
Personalization Options  
The SX6P can be customized with a personal greeting that displays when the SX6P is turned  
on. It can also be programmed to display your phone number.  
Store Your Telephone Number for Viewing  
1. Press the MENU key.  
2. Select Settings, then select Phone Settings.  
3. Select My Number.  
4. Press the EDIT key.  
5. Enter your phone number.  
6. Press the OK key.  
NOTE: To display your phone number, follow steps 1-3 above.  
Change Greeting Message  
1. Press the MENU key.  
2. Select Settings, then select Phone Settings.  
3. Select Set Greeting.  
4. Enter the desired greeting message.  
5. Use the arrow keys to change the delay time (2-20 seconds).  
6. Press the OK key.  
HINT: Use the “ ” key to switch between upper case, lower case and numbers. Use the “0” key  
*
to insert space between words/names. Use the “1” key to access special characters.  
Phonecell® SX6P GSM  
13  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Call Settings  
Minute Minder  
When turned on, the Minute Minder emits a low audible tone once every minute while a call is  
active.  
1. Press the MENU key.  
2. Select Settings, then select Call Settings.  
3. Select Minute Minder, then select On or Off as desired.  
Call Timer  
When turned on, the Call Timer displays during an active call. It can be set to remain visible for 30  
seconds after the call is terminated or until another action (key press or taking SX6P off-hook).  
1. Press the MENU key.  
2. Select Settings, then select Call Settings.  
3. Select Call Timer, then select the desired option. Options include:  
Off - no call timer displayed.  
On For 30 Sec. - call timer is displayed for 30 seconds or until user action.  
On Until Action - call timer is displayed until a user action.  
Dial Delay  
The Dial Delay is the amount of time, after a digit is dialed, the SX6P waits before automatically  
sending the call.  
1. Press the MENU key.  
2. Select Settings, then select Dial Settings.  
3. Select Dial Delay.  
4. Use the arrow keys to change the delay time(2 - 20 seconds).  
5. Press the OK key.  
Auto Dial  
The SX6P is able to recognize frequently called numbers and automatically dial them without wait-  
ing for the Dial Delay. Once a number has been called twice successfully, it will Auto Dial when this  
option is turned on.  
1. Press the MENU key.  
2. Select Settings, then select Dial Settings.  
3. Select Auto Dial.  
4. Select On to enable Auto Dial.  
Phonecell® SX6P GSM  
14  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network Settings  
Network settings allow selection of a desired network and addition of a network operator to the  
network list.  
Automatic Selection  
This option allows the SX6P to select the network automatically, based on the SIM Card account  
information.  
Manual Selection  
This allows you to see a list of networks in your area. Select the desired network from the list  
and the SX6P will attempt to use that network.  
1. Press the MENU key.  
2. Select Settings, then select Network Settings.  
3. Select Select Network.  
4. Select either Automatic or Manual.  
Set the Preferred Network  
This option allows networks to be added to the preferred list of networks. Networks on this list  
will be selected first when the SX6P searches for a network.  
NOTE: There may be several networks on the list.  
Insert New Entry  
1. Press the MENU key.  
2. Select Settings, then select Network Settings.  
3. Select Select Network.  
4. Select Set Preferred.  
5. Highlight the entry above which the new preferred carrier is to be inserted.  
6. Press the SELECT key.  
7. Select Insert.  
8. Select an entry from the list.  
Delete Entry  
1. Press the MENU key.  
2. Select Settings, then select Network Settings.  
3. Select Select Network.  
4. Select Set Preferred.  
5. Select the desired entry to delete.  
6. Select Delete.  
Phonecell® SX6P GSM  
15  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Add New Network  
If a known network is not on the list, it can be added. The Country Code, Network Code, and  
Network Name must be provided in order to add a network to the list. Once added to the network  
list, the network can be accessed via the Set Preferred Network option.  
1. Press the MENU key.  
2. Select Settings, then select Network Settings.  
3. Select Select Network.  
4. Select Add New Network.  
5. Press the SELECT key.  
6. Select Add.  
7. Enter the correct Country Code, Network Code, and Network Name as prompted.  
Edit or Delete an Added Network  
Network information can be edited or deleted.  
1. Press the MENU key.  
2. Select Settings, then select Network Settings.  
3. Select Select Network.  
4. Select Add New Network.  
5. Select the network to be edited or deleted.  
6. Select Change to edit the network information. Select Delete to delete the network from the list.  
Change Network Password (Network Dependent)  
The network password assigned by your service provider can be changed. However, this option  
may not be available from all network providers.  
1. Press the MENU key.  
2. Select Settings, then select Network Settings.  
3. Select Change Network Password.  
4. Change your password per your network provider’s instructions.  
SIM PIN Setup  
SIM PIN1 controls access to SIM Card information. When SIM PIN1 is on, it must be entered  
each time the SX6P is turned on. Another user can still access the phone with a different SIM  
Card. SIM PIN2 accesses network-controlled features.  
NOTE: Contact your network provider for information related to SIM PINs.  
Turn On/Off SIM PIN1  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select SIM PIN1.  
4. Select On or Off.  
Automatic SIM PIN Entry  
When SIM PIN1 is enabled, you must enter PIN1 every time the SX6P is powered on. To by-  
pass this entry but keep the PIN active, simply enable Auto PIN Entry. This allows the SX6P to  
remember the correct PIN the first time entered. The PIN will then be automatically entered at  
any future power on. This allows a measure of security where the SIM cannot be used in another  
device without knowing the PIN.  
1. Press the MENU key.  
2. Select Settings then Security Settings.  
3. Select Auto PIN Entry then On or Off.  
NOTE: When SIM PIN1 is disabled, this setting has no effect.  
Phonecell® SX6P GSM  
16  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Change SIM PIN1  
SIM PIN1 must be enabled and a valid PIN must be entered before this menu item will appear.  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select SIM PIN1.  
4. Select Change PIN.  
5. Enter the old PIN, then press the OK key.  
6. Enter the new PIN, then press the OK key.  
7. Enter the new PIN again, then press the OK key.  
NOTE: The PIN must be between 4 and 8 digits. Press the CLEAR key to make changes.  
Change SIM PIN2  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select SIM PIN2.  
4. Select Change PIN.  
5. Enter the old PIN, then press the OK key.  
6. Enter the new PIN. It must be numerical and between 4 and 8 digits long.  
7. Press the OK key to save the new PIN, or use the CLEAR key to make changes.  
Handset Call Barring (Requires 4 digit code to make changes).  
Use of the SX6P can be restricted by barring certain types of calls from being made or received.  
Bar All Incoming Calls  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Handset Call Barring.  
4. Select Bar Incoming, then select On. Select Off to cancel the bar.  
Bar All Outgoing Calls  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Handset Call Barring.  
4. Select Bar Outgoing, then select All. Select Off to cancel the bar.  
Bar Outgoing Calls to Specific Prefixes (No Prefixes Set)  
You can restrict outgoing calls based on prefixes or numbers that are part of a full phone num-  
ber. For example, to restrict all outgoing calls made with 847 as the first 3 digits, enter 847 as  
the prefix. A maximum of 11 digits can be entered.  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Handset Call Barring.  
4. Select Bar Outgoing, then select List.  
5. Since no prefixes have been set, List Empty will be displayed. Select OK, then select Add.  
6. Enter the prefix you want barred, then press the OK key.  
7. You can now Add, Edit, Delete, or Clear All prefixes by pressing the OPTIONS key.  
Bar Outgoing Calls to Specific Prefixes (Prefixes Set)  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Handset Call Barring.  
4. Select Bar Outgoing, then select List.  
5. The list of prefixes you have already set will be shown. You can now add a new prefix, edit or  
delete a selected prefix, or clear all prefixes by pressing OPTIONS.  
Phonecell® SX6P GSM  
17  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Add Additional Prefixes  
1. Press the OPTIONS key, then select Add.  
2. Enter the new prefix, then press the OK key.  
Edit Current Prefixes  
1. Press the OPTIONS key, then select Edit.  
2. Use the arrow and CLEAR keys to edit the prefix.  
3. Press the OK key when finished.  
Delete Prefixes  
1. Press the OPTIONS key, then select Delete.  
2. Press the OK key to delete the prefix.  
NOTE: Press the BACK key to go back to the previous menu.  
Clear All Prefixes  
1. Press the OPTIONS key, then select Clear All.  
2. Press the OK key to remove all prefixes.  
NOTE: Press the BACK key to go back to the previous menu.  
Restricted Dialing  
Outgoing calls can be restricted by creating a Fixed Dialing list that allows only numbers on that  
list to be dialed from the SX6P.  
Add to the Fixed Dialing List  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Fixed Dialing.  
4. Select Edit Dial List.  
5. Enter SIM PIN 2, then press the OK key.  
6. To add a new entry, select Add, enter the new number, then press the OK key.  
Edit the Fixed Dialing List  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Fixed Dialing.  
4. Select Edit Dial List.  
5. Enter SIM PIN 2, then press the OK key.  
6. Use the arrow keys to highlight the desired entry to edit.  
7. Press the OPTIONS key.  
8. Select Edit to change the entry. Select Delete to erase the entry.  
Activate Fixed Dialing  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Fixed Dialing.  
4. Select On.  
5. Enter SIM PIN 2, then press the OK key.  
Deskphone Lock  
Access to the SX6P menu options can be restricted by locking the phone. When the deskphone  
is locked, a PIN is required to make any calls or access any menu items. Incoming calls can still  
be received. When the SX6P is locked, press the UNLOCK key, then enter the PIN to unlock it.  
Lock the SX6P  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Deskphone Lock, then select On.  
4. Enter the PIN (default pin is 1234).  
Phonecell® SX6P GSM  
18  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Change Deskphone Lock PIN  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Deskphone Lock, then select Change PIN.  
4. Enter the old PIN, then press the OK key.  
5. Enter the new PIN, then press the OK key.  
Closed User Groups (CUG)  
This feature depends entirely on your service provider and your account subscription. Contact  
your service provider for more information.  
CUG Settings  
1. Press the MENU key.  
2. Select Settings then Security Settings.  
3. Select CUG Settings.  
Edit a CUG  
1. Press the MENU key.  
2. Select Settings then Security Settings.  
3. Select CUG Settings then select List CUGs  
4. Press Edit to edit the CUGs.  
Select a CUG  
1. Press the MENU key.  
2. Select Settings then Security Settings.  
3. Select CUG Settings then select Select  
4. Press Select on a highlighted CUG.  
Restore Factory Defaults  
All system features can be reset to the factory defaults.  
1. Press the MENU key.  
2. Select Settings, then select Restore Defaults.  
3. Select Yes to restore all factory default settings.  
Phonecell® SX6P GSM  
19  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUPPLEMENTARY SERVICES (NETWORK DEPENDENT)  
In-Call Options  
The following options are available during a call. While in a call, press the MENU key to access  
these options. Options display based on call status. For example, Retrieve will only display if a  
call is on hold or if Call Waiting indicates a second incoming call.  
Hold: Puts active call on hold.  
Retrieve: Activates a call that is on hold.  
Swap: Swaps between held call and active call.  
End Current: Ends the current call.  
Multiparty: Displays options for managing multiparty calls.  
Main Menu: Allows access to the Phonebook, Messages, or Call Log features.  
Call Divert (Forwarding)  
Call Divert sends incoming calls to another telephone number, even when the SX6P is turned off.  
Call Divert options include all calls, calls that come in when the line is busy, calls that are not  
answered after a specified number of seconds, or calls that come in when the SX6P is powered off  
or has lost the network signal (Not Found). Certain types of calls can be diverted, such as voice,  
data, fax, or text messages. Contact your service provider to activate the Call Divert feature.  
Turn On Call Divert  
1. Press the MENU key.  
2. Select Call Divert.  
3. Select the desired divert type (All Calls, When Busy, No Answer, Not Found).  
4. Select On to divert all types of calls. To specify which types of calls to divert, select By Service,  
highlight the desired service to divert, then press the SELECT key.  
5. Enter the number to which calls will be diverted, then press the OK key.  
HINT: Pressing the OK key before entering a number will display the Phonebook. Select a number,  
then press the OK key.  
Turn Off Call Divert  
1. Press the MENU key.  
2. Select Call Divert.  
3. Select the desired divert type (All Calls, When Busy, No Answer, Not Found).  
4. Select Off.  
Cancel All Diverts  
1. Press the MENU key.  
2. Select Call Divert then Cancel All Diverts.  
NOTE: When selected, all diverts will be canceled by the network.  
Phonecell® SX6P GSM  
20  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Call Waiting  
Call Waiting enables notification of incoming calls when the SX6P is off-hook (whether during a call  
or during dialing). To respond to Call Waiting, press the FLASH key or the hook switch. Contact  
your service provider to activate Call Waiting.  
Enable/Disable Call Waiting  
1. Press the MENU key, then select Settings.  
2. Select Call Settings, then select Call Waiting.  
3. Select On to enable. Select Off to disable.  
Multiparty Calling  
Multiparty Calling allows connection to several calls simultaneously. Contact your service provider  
to activate Multiparty Calling.  
Engage a Multiparty Call  
1. While in a call, put the call on hold (via the HOLD key).  
2. Dial a second number, then press the FLASH key to connect it.  
3. When the second call is answered, press the MENU key and then select Multiparty.  
4. Select the desired option.  
Join All: Join the active call with the held multiparty call.  
Hold All: Place multiparty call on hold.  
Next: Display the next call party in a multiparty call.  
Transfer: Connect one call party to another call party and allow the user to leave the call.  
Exclude: Place the selected party of a multiparty call on hold.  
Private: Hold a private call with one party in a multiparty call. Other parties are put on hold.  
I am busy: User defined user busy (UDUB) indicates BUSY to a waiting caller.  
End All: End active and held calls.  
NOTE: Options available depend on the status of the call or calls. For example, if only one  
other person is in the call, only the End All option will display, or if all the calls have been joined,  
the Join All option will not display.  
Caller ID Settings  
Caller ID settings allow personalization of how caller’s information is presented and how your  
information is presented when you call someone who has caller ID capability. Options include  
Show caller’s ID, show caller’s number, hide your ID (hides only your name information), show  
called ID, hide ID if called.  
1. Press the MENU key.  
2. Select Settings, then select Call Settings.  
3. Select Caller ID, then select the desired option.  
Blocking Your Number (CLIR)  
To hide your number when calling others enter # 31 # before you dial the phone number. For  
example, to block your phone number from appearing on 847 555 1212, simply dial # 31 # 847  
555 1212. This feature is network dependent. Check with your carrier for more information.  
Phonecell® SX6P GSM  
21  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Voicemail  
The VM key will blink and the envelope icon will display when there are new voicemail mes-  
sages. Contact your service provider to activate voicemail and for voicemail settings.  
Set Voicemail Access Numbers  
Typically, your service provider will set the voicemail access numbers for you. If they do not, con-  
tact them for the Home Mailbox , Roam Mailbox, Voice, and Message numbers.  
1. Press the MENU key.  
2. Select Messages, then select Voicemail.  
3. Select Voicemail Settings, then select Box Numbers.  
4. Select Home Mailbox, then enter the number provided by your service provider.  
5. Press the OK key.  
6. Follow steps 4 and 5 for the Roam Mailbox.  
SMS Alert Match  
Your network provider may send a text message (SMS) to alert you when you have voicemail. If  
configured, the SX6P can match this message to let you know that you have voicemail instead of  
just another text message.  
1. Press the MENU key, then select Messages.  
2. Select Voicemail, then Voicemail Settings, then Alert Match.  
3. Enter part of the text you receive when the network sends you an SMS message for voice-  
mail. You do not have to enter the whole message just part of the message.  
4. When complete, press the OK key.  
Check Voicemail  
1. Press the VM key. You will be connected to your voicemail system automatically.  
2. Follow the automated instructions.  
Short Message Service (SMS)  
The SX6P is capable of sending and receiving SMS text messages. Each SMS message can  
have a maximum of 160 characters. Upon receipt of a new SMS message, the message icon  
(envelope) will be displayed and the SMS key will blink. A maximum of 10 messages can be  
stored. Contact your service provider to activate SMS.  
SMS messages can be generated using the SX6P keypad.  
Read Received Text Messages  
1. Press the SMS key.  
2. Select Received Messages.  
3. Scroll to the desired message.  
4. Press the READ key.  
NOTE: Unread messages are denoted by a closed envelope icon.  
Reply to Received Messages  
1. View the desired message.  
2. Press the OPTIONS key.  
3. Select Text Reply to reply with a text message. Select Voice Reply to reply with a voicemail.  
4. For a text reply, type a reply message, then press the OK key. Selecting Voice Reply will acti-  
vate the speakerphone and call the person who sent the message.  
Phonecell® SX6P GSM  
22  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Forward Text Messages  
1. View the desired message.  
2. Press the OPTIONS key, then select Forward.  
3. Enter the desired number or press the NAME key to select a phonebook entry.  
4. Press the OK key.  
5. To send the message, select Send Now. To save the message to send at a later time, select  
Send Later.  
Delete Text Messages  
1. View the desired message.  
2. Press the OPTIONS key.  
3. Select Delete.  
Create Text Messages  
1. Press the SMS key.  
2. Select Create Message.  
3. Enter the message text.  
NOTE: Use the “ ” key on the keypad to change the type of text (all capital letters - ABC, lower  
*
case letters - abc, or numbers -123). The current text type is displayed under the clock in the  
upper right corner of the display screen. Use the “0” to insert spaces between words. Use the “1”  
key to access special characters.  
4. Press the OK key.  
5. Enter the desired number, or press the NAME key to select a phonebook entry.  
6. Press the OK key.  
7. To send the message, select Send Now. To save the message to send at a later time, select  
Send Later.  
View Saved Messages  
1. Press the SMS key.  
2. Select Saved Messages.  
3. Select the desired message.  
Send Saved Messages  
1. Press the SMS key.  
2. Select Saved Messages.  
3. View the desired message.  
4. Press the OPTIONS key.  
5. Select Forward.  
6. Enter the desired number or press the NAME key to select a phonebook entry.  
7. Press the OK key.  
8. To send the message, select Send Now. To save the message to send at a later time, select  
Send Later.  
Phonecell® SX6P GSM  
23  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message Settings  
Message Center  
The message center number is used to retrieve your text messages. Contact your service  
provider for this number.  
1. Press the SMS key, then select Message Settings.  
2. Select Message Center, then enter the number that your service provider gave you.  
NOTE: If the number is already entered, press the OK key.  
3. Press the OK key.  
Message Lifetime  
Message lifetime is the amount of time that an unread message will remain on the network  
server before being removed.  
1. Press the SMS key.  
2. Select Message Settings.  
3. Select Message Lifetime.  
4. Select the desired time for unread messages to remain on the network server.  
5. Press the OK key.  
Message Format  
This allows messages to be sent in different formats. Contact your service provider for infor-  
mation about which message formats are supported.  
1. Press the SMS key.  
2. Select Message Settings.  
3. Select Message Format.  
4. Select the desired message format.  
5. Press the OK key.  
Information Messages  
Information messages provide information such as phone numbers for taxi services, car rentals,  
or emergency services. If your service provider offers information messages, you can select the  
subjects to view and the language in which to view them. Contact your service provider for more  
information.  
Set Information Subjects  
1. Press the MENU key.  
2. Select Messages, then select Info messages.  
3. Select Settings, then select Subject.  
4. Select Active.  
5. Press the SELECT key.  
6. Select Add.  
7. Select the desired subject from the list.  
Set Languages  
1. Press the MENU key.  
2. Select Messages, then select Info messages.  
3. Select Settings, the select Set Languages.  
4. Select the desired language from the list.  
Phonecell® SX6P GSM  
24  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network Call Barring  
The SX6P supports network call barring of incoming or outgoing calls and allows barring of spe-  
cific types of services, such as voice or data. Contact your service provider to activate network  
call barring.  
The following call barring options are available:  
Foreign Calls: Does not allow international calls.  
Only local and home country: Only allows local and home country calls.  
Bar Incoming: Does not allow any incoming calls.  
Bar Incoming if Abroad: Does not allow any incoming calls when the SX6P is outside the  
home network country.  
Bar Outgoing: Does not allow any calls to be made.  
Bar All: Does not allow any calls to be made or received.  
Cancel All: Deactivates any network call bars that are currently active.  
Activate Call Bars  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Network Call Barring.  
4. Select the desired type of network call bar to activate  
(see list above for descriptions of each type).  
5. Select the desired service to bar.  
6. Select On.  
7. Enter the network password, then press the OK key.  
Deactivate Call Bars  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Network Call Barring.  
4. Select the desired type of network call bar to deactivate.  
5. Select the desired service to deactivate.  
6. Select Off.  
7. Enter the network password, then press the OK key.  
Check Call Bar Status  
To see which call bar options are active or inactive:  
1. Press the MENU key.  
2. Select Settings, then select Security Settings.  
3. Select Network Call Barring.  
4. Select the desired type of network call bar to check.  
5. Select the desired service, then select Status. The current setting will be displayed.  
Phonecell® SX6P GSM  
25  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DATA FEATURES (SX6P-300G series only)  
When connected to a personal computer (PC), the SX6P is capable of sending and receiving  
digital fax and data, sending and receiving email communications, and accessing the Internet.  
Data speeds may vary depending upon your cellular network.  
DB9 Data Port  
Connect SX6P to a Computer  
Use a RS232 serial cable to connect the DB-9 data port on  
the SX6P to the appropriate data port on your PC.  
Configure PC for Circuit Switched Data  
Requirements  
• Active GSM account with your network service  
provider including a Data/Fax facility  
• Windows (version 2000 or later)  
• PC with a COM Port.  
Figure 18 - DB9 Data Port on the SX6P  
NOTE: When all of the above have been satisfied, you may proceed.  
Modem Setup  
1. Power on your PC/laptop.  
2. Access the Control Panel, then select the Modems option.  
3. Install a new modem device for the SX6P with the following specifications:  
Modem Type: Standard 19200 bps Modem  
Maximum speed of serial port: 19,200  
Data bits: 8  
Parity: None  
Stop bits: 1  
Use Flow Control: Enable this option and select Hardware [RTS/CTS]  
Extra settings: AT & D1  
Automatic Baud Rate Fall Back Control  
The SX6P supports an automatic fallback to 19,200 bps when errors are detected in the data  
stream. This is useful for applications such as PC digital fax because most PC fax applications  
require a 19,200 bps baud rate on the serial port.  
Enabling Fallback  
Enable this feature when you have an application that uses a port speed of 19,200 bps. When  
the SX6P has a port speed that does not match the port speed on the PC, errors will be detect-  
ed. When these errors are detected, the SX6P will adjust the port speed to 19,200 bps, thus  
matching the PC application rate of 19,200 bps. It does not matter if the SX6P's port speed is  
higher or lower than 19,200 bps, the SX6P will still adjust the rate to 19,200 bps.  
NOTE: The SX6P does not support autobauding and will only adjust the port speed to 19,200  
bps under the above conditions. No other rate will be automatically set.  
1. Press the MENU key.  
2. Select Settings then Data Settings.  
3. Select DTE Fallback then On. (This is the factory default setting)  
When to Disable Fallback  
If you mainly use the SX6P for GPRS data, then disable fallback of the port rate. This will allow  
some errors in the data stream without effecting a change in port speed on the SX6P.  
1. Press the MENU key.  
2. Select Settings then Data Settings.  
3. Select DTE Fallback then Off.  
Phonecell® SX6P GSM  
26  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Baud Rate AT Commands  
The SX6P will accept AT commands to setup the port speed. If you want to change the SX6P  
port speed for a session or keep the change permanent, or if you just want to see the profile set-  
tings, use the following AT commands from a terminal application (like HyperTerminal).  
NOTE: Make sure DTE Fallback is OFF before making changes to the baud rate.  
View current configuration  
AT&V  
Change the port speed on the SX6P to <baud rate>  
Permanently change the SX6P port speed to <baud rate>  
AT+IPR=<baud rate>  
AT+IPR=<baud rate>  
Digital Fax Setup  
The SX6P is capable of receiving and sending faxes via a personal computer using a standard  
RS232 serial port. The PC application and modem setup must be able to support software flow  
control. To setup flow control properly, follow the instructions for setting up a standard modem  
connection in Appendix A of this manual with the following changes.  
HINT: Setup a separate modem for PC fax and a separate modem for PC circuit switched data  
connections. This way you will not have to make changes to the modem settings every time you  
want to use fax or data.  
1. Change the flow control of the standard modem to enable software flow control.  
2. Change Extra Settings from AT&D1 to AT+IFC=1,1 &d1. This enables software flow control  
on the SX6P.  
3. On the SX6P, select the serial port for your data connections by entering the MENU, then  
select Settings, then Fax Port, then Data Port, and then Serial Port (DB9).  
4. Run your PC fax application using this new modem connection for receiving and sending  
faxes.  
GPRS (Packet Data) Connections  
The SX6P will allow GPRS connectivity if your network service provider has this feature  
available. GPRS allows packet data connections at higher speeds than conventional circuit  
switched (dial-up) connections. A GPRS Kit can be used when you are connecting with GPRS  
service. This kit contains a serial cable and a setup CD for installation on a standard personal  
computer. Contact your service provider or nearest dealer for more information.  
Phonecell® SX6P GSM  
27  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SX6P TROUBLESHOOTING  
Telephone Service is Not Working (Cannot make or receive calls)  
· Make sure the SX6P is powered on properly.  
· Make sure any equipment that is externally connected to the SX6P is correctly connected.  
· Test any externally connected equipment on a known system to verify operation.  
· Make sure the antenna is properly connected.  
· Make sure your account with your service provider is activated and that service is established.  
Unable to Receive Calls  
· Is the handset on the cradle? If not, place the handset on the cradle and try again.  
· Is the SX6P making a loud, repetitive tone? Then either the speakerphone or the handset is off  
hook. Hang-up and try again.  
Unable to Make Calls  
· If you do not hear standard dial tone when off hook, then your service has a problem. Contact  
your service provider if you think this is the problem.  
Unable to Send or Receive Circuit Switched Data (CSD) Calls  
· Is your computer connected to the serial port of the SX6P? If not, connect the computer with an  
appropriate RS232 / DB-9 cable.  
· Do you have CSD service on your wireless account? Contact your service provider for information.  
· Is your computer configured properly to access data service with the SX6P? Please reference the  
data sections of this manual for proper setup.  
Unable to Connect to GPRS Service  
· Is your computer connected to the serial port of the SX6P? If not, connect the computer with an  
appropriate RS232 / DB-9 cable.  
· Do you have GPRS service on your account? Contact your service provider for information.  
· Is your computer configured properly to access GPRS with the SX6P? Please reference the data  
sections of this manual for proper setup or your GPRS setup wizard help file for more information.  
· You cannot pass the dialing sequence of the connection. Make sure that DTE Fallback is disabled.  
See the data section of the manual for more information.  
· You can dial the connection but cannot authenticate with the network. There may be a network or  
account setup problem. Contact your service provider for more information.  
Moisture or Ventilation Problems  
· Is moisture forming on or around the SX6P? Remove any moisture with a clean dry towel and  
move the unit to a well ventilated area. Review the Temperature and Environment section of this  
manual for more information.  
No Power  
· Is the power supply connected to the unit? Make sure power is available and that the power sup-  
ply is properly connected to the SX6P.  
· The power supply is connected but the unit still has no power. Make sure the circuit is functioning  
to the power supply. Check breakers & contact your power company. Power may be off at location.  
Phonecell® SX6P GSM  
28  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONFORMANCE STATEMENTS  
The SX6P 850/1900 Mhz models are in conformance with all applicable FCC requirements.  
FCC Part 15 Class B Compliance  
This Phonecell® SX6P model has been tested and found to comply with the limits for a Class B  
digital device, pursuant to Part 15 of the FCC rules. Changes or modifications not expressly  
approved by Telular Corporation will void your authority to operate the equipment per FCC part  
15 paragraph 15.21.These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in accordance with the instructions, may cause  
harmful interference to radio communications. However, there is no guarantee that interference  
will not occur in a particular installation. If this equipment does cause harmful interference to radio  
or television reception, which can be determined by turning the equipment OFF and ON, the user  
is encouraged to try to correct the interference by one or more of the following measures:  
• Reorient or relocate the antenna.  
• Increase the separation between the equipment and the terminal.  
• Connect the equipment into an outlet on a circuit different from that to which the terminal is  
connected.  
• Consult your Authorized Telular Distributor or an experienced radio/TV technician for help.  
SAFETY INFORMATION  
The Phonecell® SX6P functions as both a radio transmitter and receiver. When it is ON, the  
SX6P receives and sends out radio frequency (RF) energy. The SX6P GSM 900/1800 unit oper-  
ates in the frequency ranges of 890 MHz to 960 MHz and 1710 MHz to 1880 MHz. The  
SX6P 1900 unit operates in the frequency range of 1850 MHz to 1990 MHz. Both units employ  
commonly used phase/frequency modulation techniques. When you use the SX6P, the cellular  
system handling your call controls the power level at which the unit transmits.  
Exposure to RF (Radio Frequency) Energy  
In 1991, the Institute of Electrical and Electronics Engineers (IEEE), and in 1992, the American  
National Standards Institute (ANSI), updated the 1982 ANSI Standard for safety levels with  
respect to human exposure to RF energy. After reviewing the available body of research, more  
than 120 scientists, engineers and physicians from universities, government health agencies and  
industry developed this updated Standard. In March, 1993, the U.S. Federal Communications  
Commission (FCC) proposed the adoption of this updated Standard.  
The design of your Telular Phonecell® SX6P complies with this updated Standard. Of course, if  
you want to limit RF exposure even further than the updated ANSI Standard, you may choose to  
control the duration of your calls and operate your phone in the most power-efficient manner.  
Phonecell® SX6P GSM  
29  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safe Operation Requirement  
The Phonecell® SX6P must be either wall mounted or desk mounted and should not be operated  
when any person is within 203 mm (8 inches) of the antenna.  
Temperature Environment  
Operating Temperature: From -10°C to +50°C ; Up to 95% relative humidity (non-condensing).  
Storage Temperature: From -40°C to +60°C; Up to 95% relative humidity (non-condensing).  
Antenna Care and Replacement  
Do not use the Phonecell® SX6P with a damaged antenna. If a damaged antenna comes into  
contact with the skin, a minor burn may result. Have your antenna replaced by a qualified techni-  
cian immediately. Use only a manufacturer-approved antenna. Unauthorized antennas, modifica-  
tions, or attachments could damage the Phonecell® SX6P.  
WARNING!  
DO NOT PICK UP OR CARRY THE PHONE BY ITS ANTENNA. THIS  
!
ACTION MAY CAUSE SERIOUS DAMAGE.  
Driving  
Check the laws and regulations on the use of cellular products in the areas where you drive.  
Some jurisdictions prohibit your using a cellular device while driving a vehicle. Even if your juris-  
diction does not have such a law, we strongly suggest that, for safety reasons, the driver use  
extreme caution when operating the cellular device while the vehicle is in motion. Always obey  
the law.  
Electronic Devices  
Most modern electronic equipment is shielded from RF energy. However, RF energy from cellular  
devices may affect inadequately shielded electronic equipment.  
RF energy may affect improperly installed or inadequately shielded electronic operating and  
entertainment systems in motor vehicles. Check with the manufacturer or its representative to  
determine if these systems are adequately shielded from external RF energy. You should also  
check with the manufacturer of any equipment that has been added to your vehicle.  
Consult the manufacturer of any personal medical devices (such as pacemakers, hearing aids,  
etc.) to determine if they are adequately shielded from external RF energy.  
Turn your Phonecell® SX6P OFF in health care facilities when any regulations posted in the  
areas instruct you to do so. Hospitals or health care facilities may be using equipment that could  
be sensitive to external RF energy.  
Aircraft  
Turn OFF your Phonecell® SX6P before boarding any aircraft.  
• Use it on the ground only with crew permission.  
• Do not use it in the air.  
To prevent possible interference with aircraft systems, U.S. Federal Aviation Administration (FAA)  
regulations require you to have permission from a crew member to use your cellular phone (or  
any other cellular product) while the plane is on the ground. To prevent interference with aircraft  
systems, FCC regulations prohibit using your cellular device while the plane is in the air.  
Children  
Do not allow children to play with your Phonecell® SX6P to prevent damage to the unit.  
Blasting Areas  
Construction crews often use remote control RF devices to set off explosives. Therefore, to avoid  
interfering with blasting operations, turn your Phonecell® SX6P OFF when in a "blasting area" or  
in areas posted: "Turn off two-way radio."  
Phonecell® SX6P GSM  
30  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Potentially Explosive Atmospheres  
Turn your Phonecell® SX6P OFF when in any area with a potentially explosive atmosphere. It is  
rare, but your Phonecell® SX6P or its accessories could generate sparks. Sparks in such areas  
could cause an explosion or fire resulting in bodily injury or even death.  
Areas with a potentially explosive atmosphere are often, but not always, clearly marked. They  
include fueling areas such as gas stations; below deck on boats; fuel or chemical transfer or  
storage facilities; areas where the air contains chemicals or particles, such as grain, dust, or  
metal powders; and any other area where you would normally be advised to turn off your vehicle  
engine.  
Do not transport or store flammable gas, liquid or explosives in the area of your Phonecell®  
SX6P or accessories.  
Vehicles using liquefied petroleum gas (such as propane or butane) must comply with the  
National Fire Protection Standard (FPA-58). For a copy of this standard, contact the National Fire  
Protection Association, One Batterymarch Park, Quincy, MA 02269, Attn: Publications Sales  
Division.  
Phonecell® SX6P GSM  
31  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
I. WHAT THIS WARRANTY COVERS AND FOR HOW LONG:  
TELULAR CORPORATION ('Telular") warrants to a distributor Buyer, or to a customer only if the  
customer is a Buyer directly from Telular, that the Products (including accessories) shall comply  
with the applicable Specifications and shall be free from defects in material and workmanship  
under normal use and service for a period of fifteen (15) months from date of shipment from  
Telular. Telular, at its option, shall at no charge either repair, replace or refund the purchase price  
of the Product during the warranty period, provided it is returned by Buyer in accordance with the  
terms of this warranty to the Telular designated repair center. Repair or replacement, at Telular's  
option, may include the replacement of parts, boards or Products with functionally equivalent  
reconditioned items. Repaired and replacement items are warranted for the balance of the origi-  
nal warranty period. All replaced items shall become the property of Telular. SUCH ACTION ON  
THE PART OF TELULAR SHALL BE THE FULL EXTENT OF TELULAR'S LIABILITY HERE-  
UNDER, AND BUYERS EXCLUSIVE REMEDY. Buyer shall be responsible for all costs and  
expenses incurred by Buyer including without limitation any handling, labor or transportation  
charges. OTHER THAN AFORESAID, THIS EXPRESS WARRANTY IS EXTENDED BY TELU-  
LAR TO BUYER ONLY AND NOT TO BUYER'S CUSTOMERS OR USERS OF BUYER'S  
PRODUCTS.  
II. HOW TO OBTAIN WARRANTY SERVICE  
Product covered under this warranty shall only be accepted from and returned to Buyer's desig-  
nated repair center. Buyer's dealers, distributors, agents, and end users cannot submit items to  
Telular under this warranty. To receive warranty service an RMA number must first be obtained  
from Telular Technical Support. The defective or non-compliant Product should be sent by Buyer  
freight pre-paid to: Telular Corporation, 647 North Lakeview Parkway, Vernon Hills, IL 60061,  
USA or other designated location. The product must be packaged in the original carton and  
packing material or an equivalent package and must have the assigned RMA number clearly  
marked on the carton. Returned Product received without an RMA number will be returned to the  
sender.  
III. WARRANTY CONDITIONS:  
This is the complete warranty for the Products manufactured by Telular and sold to Buyer. Telular  
assumes no obligation or liability for additions or modifications to this warranty unless made in  
writing and signed by an officer of Telular. Unless made in separate written agreement between  
Telular and Buyer, Telular does not warrant the installation, field maintenance or service of the  
Products or parts.  
TELULAR CANNOT BE RESPONSIBLE IN ANY WAY FOR ANY ANCILLARY EQUIPMENT  
NOT FURNISHED BY TELULAR WHICH IS ATTACHED TO OR USED IN CONNECTION WITH  
THE PRODUCTS OR FOR OPERATION OF THE PRODUCTS WITH ANY ANCILLARY EQUIP-  
MENT AND ALL SUCH EQUIPMENT IS EXPRESSLY EXCLUDED FROM THIS WARRANTY.  
FURTHERMORE, TELULAR CANNOT BE RESPONSIBLE FOR ANY DAMAGE TO THE  
PRODUCTS RESULTING FROM THE USE OF ANCILLARY EQUIPMENT NOT FURNISHED  
BY TELULAR FOR USE WITH THE PRODUCTS.  
WHEN THE PRODUCT IS USED IN CONJUNCTION WITH ANCILLARY OR PERIPHERAL  
EQUIPMENT NOT MANUFACTURED BY TELULAR, TELULAR DOES NOT WARRANT THE  
OPERATION OF THE PRODUCT/PERIPHERAL COMBINATION, AND TELULAR SHALL  
HONOR NO WARRANTY CLAIM WHERE THE PRODUCT IS USED IN SUCH A COMBINA-  
TION AND IT IS DETERMINED BY TELULAR THAT THERE IS NO FAULT WITH THE PROD-  
UCT. TELULAR DISCLAIMS LIABILITY FOR RANGE, COVERAGE, AVAILABILITY, OR  
OPERATION OF THE CELLULAR SYSTEM WHICH IS PROVIDED BY THE CARRIER.  
Phonecell® SX6P GSM  
32  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. WHAT THIS WARRANTY DOES NOT COVER:  
(a) Subsequent upgrades and enhancements to the Product. (b) Defects, non-compliance or  
damage resulting from use of the Product in other than its normal and customary manner or  
environment. (c) Defects, noncompliance or damage from misuse, lightening, accident or neg-  
lect. (d) Defects, noncompliance or damage from improper testing, operation, maintenance,  
installation, adjustment, or any alteration or modification of any kind. (e) Product disassembled or  
repaired in such a manner as to adversely affect performance or prevent adequate inspection  
and testing to verify any warranty claim. (f) Product which has had the serial number removed or  
made illegible. (g) Defects, non-compliance or damage due to spills of food or liquid. (h) All plas-  
tic surfaces and all other externally exposed parts that are scratched or damaged due to cus-  
tomer normal use. (i) Costs and expenses, including without limitation handling, labor and trans-  
portation, incurred in returning Product for warranty service to Telular's Repair Center. (j) Repair,  
programming or servicing by someone other than Telular.  
V. GENERAL PROVISIONS:  
THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER EXPRESS OR STATUTORY WAR-  
RANTIES. IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WAR-  
RANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE,  
INFRINGEMENT, DELIVERY, NEGLIGENCE AND PERSONAL INJURY, ARE DISCLAIMED.  
FURTHER, AS THE CELLULAR CARRIER IS NOT CONTROLLED BY TELULAR, NO WAR-  
RANTY IS MADE AS TO COVERAGE, AVAILABILITY OR GRADE OF SERVICE PROVIDED  
BY THE CELLULAR CARRIER. IN NO EVENT SHALL TELULAR BE LIABLE FOR DAM-  
AGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF  
USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAV-  
INGS OR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT  
OF THE USE OR INABILITY TO USE SUCH PRODUCT TO THE FULL EXTENT SUCH MAY  
BE DISCLAIMED BY LAW. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR  
LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATION ON HOW  
LONG AN IMPLIED WARRANTY LASTS.  
VI. SOFTWARE PROVISIONS:  
Laws in the United States and other countries preserve for Telular certain exclusive rights for  
copyrighted Telular software such as the exclusive rights to reproduce in copies and distribute  
copies of such Telular software. Telular software may be copied into, used in and redistributed  
with only the Product associated with such Telular software. No other use, including without limi-  
tation, disassembly of such Telular software or exercise of exclusive rights in such Telular soft-  
ware is permitted and Telular reserves all rights not expressly granted in this Limited Commercial  
Warranty.  
Patents:  
Telular Corporation products are protected and manufactured under one or more of the following  
U.S. patents and related international patents and patents pending relating thereto: 4,658,096;  
4,737,975; 4,775,997; 4,868,519; 4,922,517; 5,134,651; 5,361,297; 5,469,494; 5,046,085;  
5,715,296, 6,775,522, 6,785,517  
Trademarks:  
Telular Corporation owns the following registered trademarks: TELULAR and design, TELULAR,  
CELJACK, MAXJACK, TELCEL, HEXAGON LOGO, PHONECELL, CELSERV, TELGUARD,  
CPX, and AXCELL.  
Phonecell® SX6P GSM  
33  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX A  
PC SERIAL PORT SETUP FOR CIRCUIT SWITCHED DIGITAL FAX AND  
DATA (not for use with GPRS)  
(SX6P-300G series only)  
Requirements:  
· GSM account with your network service provider including a circuit switched data and fax  
facility.  
· PC, laptop, notebook with a RS232 serial port.  
· Windows 2000 or better.  
· RS-232 Cable (DB9 to DB15).  
NOTE: When all of the above have been satisfied, you may proceed.  
Modem Setup  
1. Power on your PC or device that is connected to the SX6P.  
2. Click the “Start” button, select "SETTINGS" and then "CONTROL PANEL". Once the Control  
Panel window appears double click the MODEMS icon button. The modem properties window  
will appear.  
NOTE: Other modems may appear in the list of installed modems.  
3. Click the ADD button to install a new modem device for the phonecell.  
Phonecell® SX6P GSM  
34  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. The Install New Modem window may appear asking for the type of modem to install. Select  
"Other" followed by clicking the NEXT button. If this window does not appear, go to Step 5.  
5. The Install New Modem window will appear. Then, click on the "Don't detect my modem option"  
followed by clicking the NEXT button.  
Phonecell® SX6P GSM  
35  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. The Install New Modem will update again to select the manufacturer and the modem  
model.Select “Standard Modem Types” from the Manufacture’s list. Select “Standard 19200 bps  
Modem” from the Models list then click next.  
7. The Install New Modem will update to select the COM port. Select the COM port that will be  
connected to the SX6P then click Next. Windows will now create a modem configuration file for  
the Phonecell ® SX6P. This may take several minutes.  
Phonecell® SX6P GSM  
36  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. The Modems Properties window should appear. Click on the Properties button.  
9. The Standard 19200 bps Modem Properties window will open in the General tab. Set as shown  
with the COM port you have selected.  
10. Then click on the Connection tab. Set as shown below.  
Phonecell® SX6P GSM  
37  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. Click on the Advanced button. Set as shown.  
12. Click on OK and Close to back out of each window. Your modem is now set up.  
NOTE: When using the SX6P for PC fax operation, make sure the modem connection uses software  
flow control. When using PC data, either hardware or software flow control can be used, as long as  
the PC application (and modem) match the SX6P's configuration. The SX6P defaults to hardware  
flow control. The following AT commands are used to change the SX6P's flow control.  
Enable Software Flow Control:  
Enable Hardware Flow Control:  
Disable Flow Control:  
AT+IFC=1,1  
AT+IFC=2,2  
AT+IFC=0,0  
Phonecell® SX6P GSM  
38  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Phonecell® SX6P GSM  
39  
User anual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Phonecell® SX6P GSM  
40  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Phonecell® SX6P GSM  
41  
Technical Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
647 North Lakeview Parkway  
Vernon Hills, Illinois 60061, USA  
Tel: 847-247-9400 • Fax: 847-247-0021  
©2004 Telular Corporation, all rights reserved.  
Part Number 56031701  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toshiba DVD Player SD K780 User Manual
Toshiba Personal Computer M60 S8112TD User Manual
Tote Vision Computer Monitor LCD 1047HD User Manual
Tunturi Tent C 900 User Manual
Underwater Kinetics Work Light C4 eLED User Manual
Universal Security Instruments Smoke Alarm MP117 User Manual
Vivitar Digital Camera V3625 User Manual
Vizio Video Games M320SL User Manual
Wacom Graphics Tablet DTF 521 User Manual
Weed Eater Lawn Mower WE1538A User Manual