TPL-4052E User’s Guide  
Product Overview  
Features  
Product Overview  
TRENDnet’s 4-Port Powerline 500 AV Adapter, model TPL-4052E, uses  
an electrical outlet to create a 500 Mbps powerline network. Two  
adapters are needed to start a network. Connect network ready TVs,  
media players, game consoles, and computers to the four Ethernet  
ports. No CD installaꢀon required—encrypted TRENDnet adapters auto-  
connect out of the box. This adapter will automaꢀcally connect to other  
out of box TRENDnet Powerline AV adapters. No installaꢀon required.  
(To add up privacy on top of your network, TRENDnet recommends  
using buꢁon pressing sequence to scramble network name instead  
leave the key public as set in default.) Power saving mode reduces  
up to 80% electric consumpꢀon when network is idle. QoS, Quality  
of Service, technology prioriꢀzes video, audio, and online gaming,  
smoothing your streaming experience. LED lamps indicate device and  
port status for network monitoring and easy troubleshooꢀng. Advanced  
AES encrypꢀon secures your network. This adapter is ideal for use in  
buildings that interfere with wireless networking signals.  
Compliant with IEEE1901 and HomePlug AV standards  
High speed networking over an exisꢀng electrical system  
4 x 10/100 Mbps Auto-MDIX Fast ports  
One-touch Sync buꢁon networks adapters quickly  
Three LED indicators: Power (on/off), Powerline Link (green (best),  
amber (beꢁer), red (good), off(no connecꢀon), Ethernet Link  
(solid, blinking, off)  
TPL-4052E  
Package Contents  
Connect one Powerline 500 AV Adapter to the Internet and then  
plug in up to 15* addiꢀonal Powerline 500 AV Adapters for instant  
connecꢀvity  
Share data intensive files, play games, download music and more  
at faster data transfer rates  
Advanced 128-bit AES encrypꢀon to ensure total network security  
Power Save mode reduces electric consumpꢀon by 80%  
Network signal transmits up to 300 meters (984ſt.)  
Auto QoS support through traffic classificaꢀon and mulꢀple  
priority queuing  
TPL-4052E package includes:  
TPL-4052E: 4-Port Powerline 500 AV Adapter  
Mulꢀ-language Quick Installaꢀon Guide  
CD-ROM (Uꢀlity & User’s Guide)  
Network cable (1.5 m / 5 ſt.)  
© Copyright 2013 TRENDnet. All rights reserved.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Product Overview  
Opꢀonal management uꢀlity compaꢀble with Windows 8 (32/64-  
bit), Windows  
* 8 acꢀve adapter can stream data at the same ꢀme. Up to 16 adapters  
can be configured in the same network. Addiꢀonal adapters may decrease  
network performance. 500Mbps is the maximum theoreꢀcal powerline data  
rate. Actual throughput will vary depending on the environment. Networked  
Powerline devices must be plugged into power outlets that are on the  
same electrical system. GFCI outlets and AFCI circuit breakers may degrade  
powerline network signals.  
Power (PWR) LED  
Powerline (PL) LED  
Network 1 ~ 4  
Connect network cables  
{
from Powerline Adapter  
to your computer, game  
console, network TV, and  
other network devices.  
Product informaꢀon on device label  
Model Number  
Serial Number  
Power plug  
Network MAC Address  
Device Password (DPW)  
Hardware version  
Plugs directly into an  
available power outlet.  
Not on power strip�  
Firmware version  
Reset buꢁon  
Resets the unit to factory  
defaults.  
Sync buꢁon  
Synchronize with other  
Powerline Adapters.  
© Copyright 2013 TRENDnet. All rights reserved.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TPL-4052E User’s Guide  
Product Overview  
Push Buꢁons  
Diagnosꢀc LEDs  
Indicates the device and connecꢀon status  
Buꢁon  
Acꢀon  
Funcꢀon  
LED  
Color Sequence  
Definiꢀon  
Device powered on  
Iniꢀate Sync/Connecꢀon and generate random  
private network name on first adapter (PWR  
LED will start blinking).  
Green  
Solid  
Off  
PWR  
(Power)  
Device powered off  
N/A  
Powerline connected (Best)  
Solid  
Match the network name on secondary  
or addiꢀonal adapter and connect to first  
adapter. (PWR LED will start blinking)  
Green  
Amber  
Red  
Syncing or Powerline data  
transmiꢂng/receiving (Best)  
Sync  
Push and hold  
for 2 seconds  
Blinking  
Solid  
(see Using  
the Sync  
Buꢁon  
Powerline connected (Beꢁer)  
Note: To establish connecꢀvity, the secondary  
or addiꢀonal Powerline Adapter’s Sync buꢁon  
must also be pushed within 2 minutes (120  
sec) of pushing the Sync buꢁon of the first  
adapter�  
Secꢀon for  
instrucꢀons)  
Powerline data transmiꢂng/receiving  
(Beꢁer)  
PL  
(Powerline)  
Blinking  
Solid  
Powerline connected (Good)  
Powerline data transmiꢂng/receiving  
(Good)  
Blinking  
Erases the network name  
(All LEDs will turn off and turn back on).  
Push/hold for  
15 seconds  
Powerline is not synced or  
connected  
Network connecꢀon established  
Data transmission is detected  
Network standby or no network  
connecꢀon  
N/A  
Green  
N/A  
Off  
Reset device to factory defaults (All LEDs will  
turn off and turn back on).  
Note: Will reset to the factory default private  
network name “HomePlug AV.  
Push/Hold for  
1 second only  
Solid  
Blinking  
1-4  
Reset  
(Fast  
Ethernet  
Connecꢀon)  
Off  
Save Mode: The device will automaꢀcally standby to reduce power usage when there  
is no network traffic for more than 10~20 minutes. It will automaꢀcally resume back  
to full speed service when traffic resumes.  
Note: Powerline (PL) LED color indicates the strength and quality of the Powerline  
connecꢀon through the electrical system. The following factors may affect the  
powerline network’s connecꢀon quality:  
Noise – Generated by appliances which use your electrical system (e.g.  
Microwaves, ovens, hair dryer, irons, dishwashers, etc.). The quality of your  
household electrical wiring may also cause addiꢀonal noise on your electrical  
system.  
Distance – Long lengths of electrical wiring through your electrical system  
between connected Powerline Adapters.  
© Copyright 2013 TRENDnet. All rights reserved.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TPL-4052E User’s Guide  
Product Overview  
Applicaꢀon Diagram  
Diagram Explanaꢀon:  
The first Powerline unit is networked  
to a router which is in turn  
connected to a modem (typically  
supplied by your Internet Service  
Provider (ISP)) that provides Internet  
connecꢀvity. A second Powerline  
Adapter is plugged into a wall power  
outlet near a media center and is  
providing Internet connecꢀvity to a  
game a game console and a Blu-ray  
player / media player via Ethernet.  
© Copyright 2013 TRENDnet. All rights reserved.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Installing Your Powerline Adapter  
Connecꢀng a Powerline Adapter to your router  
Installing Your Powerline Adapter  
1. Plug the Powerline Adapter into an available wall power outlet near  
your router�  
Before you install  
Note: This will allow devices connected to your powerline network to  
access the Internet and other devices connected to your network.  
1. Before you proceed with the installaꢀon, verify the following:  
Verify that you already have Internet access through your  
exisꢀng network.  
Verify that you have an available Ethernet port (also known as a  
LAN port) on you router.  
Verify that you have at least two Powerline Adapters. Two or  
more Powerline Adapters are required to create a powerline  
network�  
2. Connect the included Ethernet cable (also called a network cable)  
from the Ethernet port (also called network port) of your Powerline  
Adapter to an available Ethernet port (also called LAN port) on your  
router�  
3. Once the Powerline Adapter is installed and connected to your  
router, verify that the Power (PWR) LED is on or blinking and the  
Network LED is on or blinking.  
Note: The TPL-4052E package only includes a single Powerline  
Adapter. Please ensure that your other Powerline Adapter is  
HomePlug® AV or IEEE 1901 compliant (e.g. TRENDnet models  
TPL-401E, TPL-402E, TPL-405E , TPL-406E , TPL-407E or another  
TPL-4052E.)  
2. Plan the locaꢀon of where you will install your Powerline Adapters.  
Avoid plugging the adapters into power strips, extension cords,  
or surge protectors as this may prevent the adapter from  
funcꢀoning correctly or degrade performance.  
Avoid plugging the adapters into wall power outlets that are  
controlled by a light switch to prevent the Powerline Adapter  
from being turned off accidentally.  
Avoid plugging the adapters into wall power outlets that  
are located near appliances that consume a lot of power  
(e.g. refrigerators, washers, dryers) as this may degrade  
performance�  
TPL-4052E  
Make sure there is an available wall power outlet in the room  
where the router is installed and also near the router.  
Make sure there is an available wall power outlet in the room  
where you want to extend network connecꢀvity.  
© Copyright 2013 TRENDnet. All rights reserved.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
TPL-4052E User’s Guide  
Installing Your Powerline Adapter  
Adding adapters to your network  
Once you have installed and connected the first Powerline Adapter  
to your router, you can easily extend your network to other rooms by  
adding addiꢀonal Powerline Adapters.  
To extend your network using an addiꢀonal Powerline Adapter:  
1. First, make sure the first Powerline Adapter is installed and  
connected to your router�  
Note: This will allow devices connected to your powerline network to  
access the Internet and other devices connected to your network. See  
2. Plug in the addiꢀonal Powerline Adapter to an available wall power  
outlet in another room near a computer or network device (e.g. game  
consoles, network-enabled TVs, network aꢁached storage, network  
media server/players, etc.) you want to connect to your network.  
3. Connect one end of the included Ethernet cable to the Ethernet  
port on your Powerline Adapter and then connect the other end to the  
Ethernet port on your computers or another network enabled device.  
4. Aſter the addiꢀonal Powerline Adapter is connected and installed to  
your computer or network device, wait for the Powerline (PL) LED to  
turn on. Aſter the Powerline (PL) LED turns on, verify that the Power  
(PWR) LED is on, the Powerline (PL) LED is on or blinking, and the  
network LED is on or blinking.  
to your network, you can check if the computer(s) or network device(s)  
can access the Internet through your powerline network.  
Note: To verify that your Powerline Adapters are connected successfully  
To install addiꢀonal Powerline Adapters in other rooms, repeat the  
steps above for each adapter�  
© Copyright 2013 TRENDnet. All rights reserved.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Securing Your Powerline Network  
Using the Sync buꢁon  
Secure Your Powerline Network  
Change your default network name using the Sync buꢁon  
Powerline Adapters join powerline network by using network name.  
The default network name is “HomePlugAV. All out-of-the-box  
TRENDnet HomePlugAV Powerline Adapters have the same default  
network name and can be connected to each other without further  
configuraꢀon. To add network security to your network, you can change  
your Powerline network name away from the factory default name.  
With a private custom network name, no one can connect to your  
Powerline network with an out-of-the-box HomePlugAV adapter.  
The physical Sync buꢁon on the Powerline Adapter provides an easy  
method of changing the network name� The Sync buꢁon generates  
a random network name for your powerline network. To create a  
9�  
Note: The default network name assigned to TRENDnet Powerline  
Adapters is HomePlugAV. Before changing the default network name,  
please make sure your Powerline Adapters are already installed and  
connected using the default network name.  
TRENDnet recommends you change the Powerline network name  
away from the factory default name to increase network security. Once  
configured, the Powerline network name will be saved. The adapter  
can be moved freely within its operaꢀng range without having to  
reconfigure the network name. If a mistake is made in the seꢂngs,  
the adapter can be reset to the factory default seꢂngs by pressing the  
reset Reset buꢁon for 1 second.  
There are two ways to change the default network name:  
1� (Recommended) Use the physical Sync buꢁon on your  
Powerline Adapter to generate a random private network name.  
See “Using the Sync Buꢁon” in next secꢀon.  
OR  
2� Create a customized private network name for your powerline  
network by using the included Powerline Uꢀlity. See “Using the  
* If the Powerline Adapter seꢂngs have been changed, the  
adapter must be reset to the factory default seꢂngs to be  
recognized by Powerline Uꢀlity.  
© Copyright 2013 TRENDnet. All rights reserved.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Securing Your Powerline Network  
the new network name. All LEDs will turn off and turn back on and the  
Powerline (PL) LED will turn on the when adapters are connected.  
Changing the network name and associaꢀng two Powerline  
Adapters:  
Note: Use the Sync buꢁon procedure below if you are connecꢀng  
TRENDnet Powerline models TPL-401E, TPL-402E, TPL-405E , TPL-406E ,  
TPL-407E or TPL-4052E.  
Adding adapters using the Sync buꢁon  
1. Verify that all Powerline Adapters are already installed and  
connected using the default network name, see “Installing Your  
If you have changed the default network name assigned to your  
Powerline Adapters, addiꢀonal adapters will not automaꢀcally connect  
to your powerline network aſter they are plugged into a wall power  
outlet. You have to change the network name on addiꢀonal Powerline  
Adapter in order to join your exisꢀng powerline network.  
Prepare your adapters:  
2. On one of the connected Powerline Adapters, push and hold the  
Sync buꢁon for 15 seconds and then release it. All LEDs will turn off and  
turn back on. This will erase the current network name assigned to the  
first Powerline Adapter.  
Note: Once you have completed this step, the other Powerline Adapter  
will no longer be able to communicate to this Powerline Adapter.  
3. On the other Powerline Adapter, push and hold the Sync buꢁon for  
15 seconds then release it. All LEDs will turn off and turn back on. This  
will erase the current network name assigned to the second Powerline  
Adapter�  
Start associaꢀon:  
4. Within 2 minutes, push and hold the Sync buꢁon on the first  
Powerline Adapter for 2 seconds and then release it. The Power (PWR)  
LED will start blinking. This will generate a random network name on  
the first Powerline Adapter.  
5. Push and hold the Sync buꢁon on the second Powerline Adapter  
for 2 seconds and release it. The Power (PWR) LED will start blinking.  
This will create a connecꢀon between both Powerline Adapters using  
© Copyright 2013 TRENDnet. All rights reserved.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Securing Your Powerline Network  
Configuring an addiꢀonal Powerline Adapter to connect and  
use the network name of your exisꢀng powerline network:  
Using the Powerline Uꢀlity  
The Powerline Uꢀlity allows you doing following jobs:  
1� Create a customized network name for your powerline network  
and apply it to mulꢀple Powerline Adapters at the same ꢀme.  
2� View Powerline Adapters connected to your network (using  
the MAC address) and the approximate connecꢀon quality and  
speed of each Powerline Adapter.  
Note: Use the Sync buꢁon procedure below if you are connecꢀng  
TRENDnet Powerline models TPL-401E, TPL-402E, TPL-405E , TPL-406E ,  
TPL-407E or TPL-4052E.  
1� Verify that all exisꢀng Powerline Adapters are already installed and  
connected�  
3� View and upgrade Powerline Adapter firmware.  
Note: Link speed displayed in the uꢀlity of your Powerline  
Adapters to another through your electrical system is esꢀmated.  
Actual link speed may vary.  
Prepare your adapter:  
2� Push and hold the Sync buꢁon on the addiꢀonal Powerline Adapter  
for 15 seconds and then release it. All LEDs will turn off and turn  
back on. This will erase the current network name assigned to the  
addiꢀonal Powerline Adapter.  
Before installing and using the uꢀlity, please ensure the following:  
1. Write down the Device Password (DPW) (16-digit characters  
A-Z only) and MAC Address (12-digit characters a-f, A-F, 0-9) of  
each Powerline Adapter as this will be required to change the  
network name for mulꢀple Powerline Adapters. See “Product  
Start associaꢀon:  
3� Push and hold the Sync buꢁon on one of the exisꢀng Powerline  
Adapters connected to your powerline network for 2 seconds and  
then release it. The Power (PWR) LED will start blinking.  
2. Make sure your computer in which you are installing the uꢀlity  
is connected to your network and your Powerline Adapters are  
also connected to your network.  
3. If you have changed your network name using the Sync buꢁon  
and you are creaꢀng a customized network name, it is required  
to reset all powerline devices to factory defaults using the  
physical Reset buꢁon on your Powerline Adapter before using  
4� Within 2 minutes, push and hold the Sync buꢁon on the addiꢀonal  
Powerline Adapter for 2 seconds and release it. The Power  
(PWR) LED will start blinking. This will reconfigure your addiꢀonal  
Powerline Adapter to connect and use the network name of your  
exisꢀng powerline network. All LEDs will turn off and turn back on  
and the Powerline (PL) LED will turn on the adapters are connected.  
4. Please ensure that your Powerline Adapters are already  
installed and connected and the Ethernet port on each adapter  
is connected to a device powered on.  
Configure to add addiꢀonal Powerline Adapters to your exisꢀng  
powerline network, repeat the steps above for each adapter.  
© Copyright 2013 TRENDnet. All rights reserved.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TPL-4052E User’s Guide  
Powerline Utility  
The installer will check if you have a previous WinPcap uꢀlity.  
4. Click OK�  
Powerline Uꢀlity System Requirements  
Windows 8 (32/64-bit), Windows 7 (32/64-bit), Windows Vista  
(32/64-bit), or Windows XP (32/64-bit)  
Microsoſt® .NET Framework 3.5 installed  
Soſtware Installaꢀon  
1. Insert the included CD-ROM into your computer’s CD-ROM drive.  
Note: The Powerline Uꢀlity requires WinPcap as a base applicaꢀon. If this  
prompt does not appear, you may already have the WinPcap applicaꢀon  
installed. Windows 8 require WinPcap 4.1.3. Windows 7 and older will work  
with previous versions of WinPcap. If you have installed a previous version of  
WinPcap, please uninstall it manually. And then, start the installaꢀon from the  
beginning.  
2. At the CD Autorun Prompt window, click Run Autorun.exe �  
Note: If the Autorun prompt does not appear automaꢀcally, open the CD  
contents and double-click Autorun.exe.  
3. At the CD-ROM main menu, click Install Uꢀlity�  
5� At the WinPcap installer window, click Next�  
© Copyright 2013 TRENDnet. All rights reserved.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
6. Click Yes to allow installaꢀon.  
8. In the Installaꢀon Opꢀons window, leave the Automaꢀcally start the  
WinPcap driver at boot ꢀme checked and click Install�  
7. Review the license agreement and click I Agree�  
9. Wait for the WinPcap installaꢀon to complete.  
© Copyright 2013 TRENDnet. All rights reserved.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
12. In the License Agreement window, click I Agree, and then click Next.  
10. Aſter the process has been completed, click Finish�  
13. In the Select Installaꢀon Folder window, click Next�  
11. At the TRENDnet Powerline Uꢀlity Setup Wizard, click Next�  
14. In the Confirm Installaꢀon window, click Next�  
© Copyright 2013 TRENDnet. All rights reserved.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Using the Uꢀlity  
Before using the uꢀlity, please ensure the following:  
1. Write down the Device Password (DPW) (16-digit characters  
A-Z only) and MAC Address (12-digit characters a-f, A-F, 0-9) of  
each Powerline Adapter as this will be required to change the  
network name for mulꢀple Powerline Adapters. See “Product  
2. Make sure the computer in which you are installing the uꢀlity  
is connected to your network and your Powerline Adapters are  
also connected to your network.  
3. If you have changed your network name using the Sync buꢁon  
and you are creaꢀng a customized network name, it is required  
to reset all powerline devices to defaults using the physical  
Reset buꢁon on your Powerline Adapter first before using the  
4. Please ensure that your Powerline Adapters are already  
installed and connected and the Ethernet port on each adapter  
is connected to a device powered on.  
15. Wait for the Powerline Uꢀlity installaꢀon to complete. At the  
Installaꢀon Complete window, click Close�  
Upon compleꢀng the soſtware installaꢀon, a desktop shortcut is  
automaꢀcally created. Double-click the icon to start the uꢀlity or  
open the uꢀlity if it is already running. Closing the uꢀlity will exit the  
applicaꢀon.  
You can also launch the uꢀlity from Start Menu.  
Start > Programs (or All Programs) > TRENDnet >  
TRENDnet Powerline Uꢀlity  
© Copyright 2013 TRENDnet. All rights reserved.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Powerline Uꢀlity - Map View  
Auto Scan  
Auto Scan is selected by default. The  
uꢀlity will scan for remote devices in  
specific intervals (default: 2 sec, you  
can change it from 2 to 60 secs).  
Auto scan can be disabled by  
deselecꢀng it. Remote adapters can be  
scanned manually by clicking the Scan  
buꢁon below.  
Local Device  
All Powerline Adapters connected to  
the same network as your computer  
will be listed here.  
The default device name is main chip  
number, followed by the MAC address  
and firmware version number. You  
can mouse over the header and adjust  
column width by clicking and dragging  
Network Type  
The default network type is public.  
When the network name is customized  
and changed, it becomes private.  
this cursor  
.
Remote Devices  
These are Powerline Adapters in  
remote locaꢀons connected to a  
selected local Powerline Adapter on  
the electrical system.  
Scan  
You can mouse over the header and  
adjust the column width by clicking  
and dragging this cursor to see more  
informaꢀon.  
Manually scan remote Powerline  
devices which has same network name  
Enter Password  
Manage your device  
Highlight a device by  
clicking the row and click  
buꢁons below  
Rename  
Add Device  
Add remote Powerline Adapter  
Enter device DPW here. You can  
manage the remote adapter if  
only you enter the DPW.  
Change device name  
to meaningful names  
such as “living room”  
* DPW (Device Password) is shown on device label  
** TPL-4052E has a Power Save Mod. The device seꢂng can only be changed when the device is acꢀve.  
To keep remote Powerline Adapter in an acꢀve state, you can power cycle the device or connect it to a  
network device, such as a router or a computer.  
© Copyright 2013 TRENDnet. All rights reserved.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Rename remote device  
(Click and select a remote device and then click Rename buꢁon in Map  
Add Device  
(Click Add Device buꢁon in Map View)  
View)  
Enter a meaningful name for easy management  
Enter Password  
Enter device name and DPW to add an adapter manually  
(Click and select a remote device and then click Enter Password buꢁon  
in Map View)  
Scan  
Click Scan buꢁon in Map View to scan other powerline devices  
manually.  
The device password (DPW) can be found on device label. You have to  
enter DPW in order to manage Powerline Adapter remotely.  
© Copyright 2013 TRENDnet. All rights reserved.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Powerline Uꢀlity - Detailed View  
System Informaꢀon  
System Informaꢀon secꢀon shows  
this uꢀlity version, your computer  
informaꢀon, network adapters  
installed on your computer.  
Remote Devices  
Powerline Adapters in remote locaꢀons  
connect to your network shows here�  
Show Acꢀve Device(s) Only  
Un-check this check box, you can  
include all device informaꢀon on  
network, even it is not in acꢀve state.  
Manage your report  
Delete  
Save Report  
Print Report  
Highlight the device by  
clicking the row and click status report (Un-select  
buꢁons below  
Delete the device from  
Click this buꢁon  
to save above  
Click this buꢁon  
sending above  
auto scan in About secꢀon informaꢀon for later informaꢀon to your  
to prevent the deleted  
use.  
default printer.  
device added in again.)  
* DPW (Device Password) is shown on device label  
© Copyright 2013 TRENDnet. All rights reserved.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Powerline Uꢀlity - Device Setup  
Private Network Name  
Use Default  
This is the network name of your  
powerline network. Default is  
“HomePlugAV. When network name  
set to “HomePlugAV, it considered  
a public network because very out of  
box Powerline Adapter can join this  
network. Powerline Adapters connect  
to each other only when network  
name is the same� Change network  
name and make your network private  
is recommended to increase your  
privacy.  
If you don’t remember what network  
name you set previously, you can set  
the network public. Then set it back to  
private later.  
Set Local Device  
Change network name on device  
selected above.  
Set Remote Devices  
All devices currently connected locally to  
your computer or connected remotely  
through powerline network will set to  
the new network name�  
You have to remember your network  
name (Private Network Name). It will  
be encrypted and save to device. Even  
Powerline Uꢀlity cannot read it in plain  
text again. When you visit this Private  
Seꢂngs again and the Private Network  
Name show UnknownNetworkName, it  
means the network name is private.  
Mulꢀcast Address  
Click this buꢁon to synchronize mulꢀcast  
address on all adapters on same  
powerline network.  
© Copyright 2013 TRENDnet. All rights reserved.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Powerline Uꢀlity - Advanced  
Select Local Device  
This advanced feature supports local devices only. Choose one of  
your local device and proceed the advance seꢂng.  
Upgrade Firmware  
Click this buꢁon to upgrade device firmware.  
Reset Device  
Cleanup device acꢀve jobs and start fresh again.  
Factory Defaults  
Clean up all your seꢂngs on adapter. Always click this buꢁon aſter  
you upgrade firmware.  
Set VLAN Tags  
Set VLAN tag for stream idenꢀty  
Set TOS Bits  
Setup Type-of-Service bits to  
differenꢀate packets  
© Copyright 2013 TRENDnet. All rights reserved.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Powerline Uꢀlity - Opꢀons  
Scan Opꢀons  
By default, the Powerline uꢀlity scans  
adapters aꢁached to the network every  
2 seconds. You can change the scanning  
frequency from 2 seconds tup to 60  
seconds or stop auto scan. You can then  
scan devices manually by clicking Scan  
buꢁon in Map View.  
© Copyright 2013 TRENDnet. All rights reserved.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Powerline Utility  
Powerline Uꢀlity - About  
About Powerline Uꢀlity  
This Powerline Uꢀlity manages TPL-  
4052E and most legacy HomePlug  
cerꢀfied Powerline Adapters.  
For more informaꢀon, please visit our  
website www�trendnet�com  
© Copyright 2013 TRENDnet. All rights reserved.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Technical Specifications  
Technical Specificaꢀons  
Hardware  
Standards  
LED  
Power (PWR)  
Powerline (PL) with Connecꢀon Quality  
Indicaꢀon  
IEEE 1901, HomePlug® AV, IEEE 802.3, IEEE  
802.3x, IEEE 802.3u  
4 x 10/100 Mbps Fast Ethernet Auto-  
Interface  
Best (Green)  
Beꢁer (Amber)  
Good (Red)  
MDIX RJ-45 ports  
Power plug  
o
o
o
A: North America Type B (NEMA 5–15)  
EU: Euro Type C (CEE 7/16)  
UK : United Kingdom Type G (BS 1363)  
No connecꢀon (Off)  
Fast Ethernet Connecꢀon (1-4)  
Solid  
Blinking  
Off  
2 ~ 50 MHz  
Frequency Band  
Modulaꢀon  
OFDM Symbol Modulaꢀon on link  
synchronizaꢀon, 1024/256/64/8 - QAM, QPSK,  
BPSK, ROBO Carrier  
Buꢁons  
Sync, Reset  
Dimension (L x W  
X H)  
A: 105 x 75 x 57 mm (4.1 x 3.0 x 2.2 in.)  
EU: 105 x 75 x 73 mm (4.1 x 3.0 x 2.87 in.)  
UK: 105 x 75 x 65 mm (4.1 x 3.0 x 2.56 in.)  
TDMA, and CSMA/CA  
Protocol  
Speed  
Powerline: up to 500Mbps**  
Ethernet: up to 200Mbps with Full Duplex  
mode per port  
Weight  
A: 147 g (5.2 oz)  
EU: 170 g (6.0 oz)  
UK: 159 g (5.6 oz)  
Windows 8 (32/64-bit), Windows 7 (32/64-bit),  
Vista (32/64-bit), XP(32/64-bit)  
Uꢀlity OS  
Compaꢀbility  
Power Source  
100~240V AC, 50~60Hz  
Configuring up to 16 nodes  
Acꢀve nodes up to 8 nodes for simultaneous  
access  
Nodes  
Consumpꢀon  
Acꢀve mode: 4 Waꢁs (max.)  
Standby mode: 0.5 Waꢁs (max.)  
Temperature  
Operaꢀng: 0° ~ 40°C (32° ~ 104°F)  
Storage: -20° ~ 70°C (-4° ~ 158°F)  
Up to 300m (984ſt.)  
Coverage  
128-Bit AES (Advanced Encrypꢀon Standard)  
Security  
Humidity  
Max. 90% (non-condensing)  
CE, FCC, HomePlug® AV  
Cerꢀficaꢀons  
* 8 acꢀve adapter can stream data at the same ꢀme. You can configure up to 16 adapters in the same network. Addiꢀonal adapters may decrease network performance. 500Mbps is the  
maximum theoreꢀcal Powerline data rate. Actual throughput will vary depending on environment. Networked Powerline devices need to be plugged into power outlets that are on the  
same electrical system. GFCI outlets and AFCI circuit breakers may degrade powerline network signals.  
© Copyright 2013 TRENDnet. All rights reserved.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Troubleshooting  
Troubleshooꢀng  
Please reference the items below if you conꢀnue to experience  
difficulty with installing and using your Powerline Adapters.  
In addiꢀon to this User’s Guide, you can find help below:  
(documentaꢀon, downloads, FAQs, how to contact technical  
support)  
Power-cycle the Powerline Adapters by disconnecꢀng them from their power  
outlets for 15 seconds and then reconnect them.  
Autorun CD (Quick Installaꢀon Guide)  
If the Powerline (PL) LED is red, try plugging the Powerline Adapter into another  
available power outlet. The quality of the connecꢀon may be beꢁer in a different  
power outlet.  
If you are having issues connecꢀng the Powerline Adapters aſter changing the  
network name using the Sync buꢁon or Powerline uꢀlity, reset the Powerline  
Adapters to defaults using the physical Reset buꢁon.  
Using a pin or paperclip; press and hold the Reset buꢁon for 1 second on each  
Powerline Adapter. All LEDs will turn off then turn back on. This will reset the  
Powerline Adapters to their default seꢂngs. The default network name is  
HomePlugAV.  
The Powerline Adapters can provide beꢁer connecꢀvity and performance when  
plugged directly into a power outlet. Connecꢀng the Powerline Adapters to a  
power strip or surge protector may degrade or block Powerline signals.  
Avoid using the Powerline Adapters on GFI protected outlets and electrical  
systems with AFCI circuit breakers. They may degrade or block powerline signals.  
The Powerline Adapters should not be used in areas with excessive heat.  
Florescent and incandescent lighꢀng can generate significant powerline  
interference�  
If your building has more than one circuit breaker box, the Powerline Adapter  
may not be able to establish connecꢀvity between them. In this case, connect  
a Powerline Adapter into a power outlet located on each of the circuit breaker  
boxes. Then connect an Ethernet cable between the Powerline Adapters to  
bridge the two circuits together.  
© Copyright 2013 TRENDnet. All rights reserved.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Appendix  
Appendix  
Move Powerline Adapters between different overlapping  
powerline networks  
Overlapping powerline networks  
It is possible to create mulꢀple powerline networks on the same  
electrical system separated and grouped by different network  
network names. The powerline networks will work and communicate  
independently of each other which can provide security between  
different groups of Powerline Adapters. For example, if you have  
five Powerline Adapters (Adapter A, Adapter B, Adapter C, Adapter  
D, Adapter E), you can group Adapters A,B, and C together on one  
powerline network and group Adapters D and E on a different  
powerline network. Each group will use a different network name.  
Note: Assuming all Powerline Adapters are TRENDnet Powerline Adapters and for  
reference in the diagram and this procedure, the adapters will be labeled Adapter  
A, B, C, D, and E. Adapters A, B, and C are currently connect together to form one  
powerline network and Adapters D and E form another powerline network. Adapter B  
will be disconnected from Adapters A and C and connected to Adapters D and E.  
Note: It is recommended that only a maximum of up to 4 powerline networks can  
be created per electrical system. Any addiꢀonal powerline networks above the  
recommended may result in significant degradaꢀon in powerline performance.  
1. Push and hold the Sync buꢁon on Adapter B for 15 seconds and  
release it. All LEDs will turn off and turn back on. This will erase the  
current network name assigned to Adapter B and disconnect from  
Adapter A and Adapter C�  
2. Push and hold the Sync buꢁon on Adapter D for 2 seconds and  
release it. The Power (PWR) LED will start blinking.  
© Copyright 2013 TRENDnet. All rights reserved.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Appendix  
3. Within 2 minutes, push and hold the Sync buꢁon on Adapter B for  
2 seconds and release it. The Power (PWR) LED will start blinking.  
This will establish connecꢀvity between Adapter B, Adapter D, and  
Adapter E by reconfiguring the network name of Adapter B to match  
the network name of Adapter D and Adapter E. All LEDs will turn off  
and turn back on and the Powerline (PL) LED will turn on the when  
adapters are connected�  
© Copyright 2013 TRENDnet. All rights reserved.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Declaration of Conformity  
This transmiꢁer must not be co-located or operaꢀng in conjuncꢀon with any  
other antenna or transmiꢁer.  
The availability of some specific channels and/or operaꢀonal frequency bands  
are country dependent and are firmware programmed at the factory to match  
the intended desꢀnaꢀon. The firmware seꢂng is not accessible by the end  
user�  
Federal Communicaꢀon Commission Interference Statement  
This equipment has been tested and found to comply with the limits for a  
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are  
designed to provide reasonable protecꢀon against harmful interference in  
a residenꢀal installaꢀon. This equipment generates uses and can radiate  
radio frequency energy and, if not installed and used in accordance with  
the instrucꢀons, may cause harmful interference to radio communicaꢀons.  
However, there is no guarantee that interference will not occur in a parꢀcular  
installaꢀon. If this equipment does cause harmful interference to radio or  
television recepꢀon, which can be determined by turning the equipment off  
and on, the user is encouraged to try to correct the interference by one of the  
following measures:  
RoHS  
This product is RoHS compliant.  
Reorient or relocate the receiving antenna.  
Increase the separaꢀon between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that  
to which the receiver is connected.  
Europe – EU Declaraꢀon of Conformity  
This device complies with the essenꢀal requirements of the Direcꢀve  
2004/108/EC, /2006/95/EC and 2009/125/EC:  
Consult the dealer or an experienced radio/TV technician for help.  
FCC Cauꢀon: Any changes or modificaꢀons not expressly approved by the  
party responsible for compliance could void the user’s authority to operate  
this equipment.  
This device complies with Part 15 of the FCC Rules. Operaꢀon is subject to the  
following two condiꢀons: (1) This device may not cause harmful interference,  
and (2) this device must accept any interference received, including  
interference that may cause undesired operaꢀon.  
EN55022 : 2010, class B  
EN 61000-6-3 : 2007 + A1 :2011  
EN 61000-3-2 : 20086 + A1 : 2009 + A2 : 2009,  
class A  
EN 61000-3-3 : 2008  
EN 50412-2-1 :2005, class 1, type 2  
EN 60950-1 :2006 + A11 : 2009 + A1 : 2010 + A2 : 2011 : Safety of Informaꢀon Technology Equipment  
including electrical business equipment  
IMPORTANT NOTE:  
FCC Radiaꢀon Exposure Statement:  
This equipment complies with FCC radiaꢀon exposure limits set forth for an  
uncontrolled environment. This equipment should be installed and operated  
with minimum distance 20cm between the radiator & your body.  
© Copyright 2013 TRENDnet. All rights reserved.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Declaration of Conformity  
cs  
nl  
TRENDnet ꢃmto prohlašuje, že tento TPL-4052E je ve shodě  
se základními požadavky a dalšími příslušnými ustanoveními  
směrnice 2004/108/ES.  
Undertegnede TRENDnet erklærer herved, at følgende  
udstyr TPL-4052E overholder de væsentlige krav og øvrige  
relevante krav i direkꢀv 2004/108/EF.  
Hiermit erklärt TRENDnet, dass sich das Gerät TPL-4052E in  
Übereinsꢀmmung mit den grundlegenden Anforderungen  
und den übrigen einschlägigen Besꢀmmungen der Richtlinie  
2004/108/EG befindet.  
Käesolevaga kinnitab TRENDnet seadme TPL-4052E  
vastavust direkꢀivi 2004/108/EÜ põhinõuetele ja nimetatud  
direkꢀivist tulenevatele teistele asjakohastele sätetele.  
Hereby, TRENDnet, declares that this TPL-4052E is in  
compliance with the essenꢀal requirements and other  
relevant provisions of Direcꢀve 2004/108/EC.  
Por medio de la presente TRENDnet declara que el TPL-  
4052E cumple con los requisitos esenciales y cualesquiera  
otras disposiciones aplicables o exigibles de la Direcꢀva  
2004/108/CE.  
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ TRENDnet ΔΗΛΩΝΕΙ ΟΤΙ TPL-4052E  
ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ  
ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 2004/108/ΕΚ.  
Par la présente TRENDnet déclare que l’appareil TPL-4052E  
est conforme aux exigences essenꢀelles et aux autres  
disposiꢀons perꢀnentes de la direcꢀve 2004/108/CE.  
Con la presente TRENDnet dichiara che questo TPL-4052E  
è conforme ai requisiꢀ essenziali ed alle altre disposizioni  
perꢀnenꢀ stabilite dalla direꢂva 2004/108/CE.  
Ar šo TRENDnet deklarē, ka TPL-4052E atbilst Direkꢄvas  
2004/108/EK būꢀskajām prasībām un ciꢀem ar to  
saisꢄtajiem noteikumiem.  
Hierbij verklaart TRENDnet dat het toestel TPL-4052E in  
overeenstemming is met de essenꢀële eisen en de andere  
relevante bepalingen van richtlijn 2004/108/EG.  
Hawnhekk, TRENDnet, jiddikjara li dan TPL-4052E  
jikkonforma mal-ħꢀġijiet essenzjali u ma provvedimenꢀ  
oħrajn relevanꢀ li hemm fid-Dirreꢂva 2004/108/EC.  
Alulíroꢁ, TRENDnet nyilatkozom, hogy a TPL-4052E megfelel  
a vonatkozó alapvetõ követelményeknek és az 2004/108/EC  
irányelv egyéb elõírásainak.  
Niniejszym TRENDnet oświadcza, że TPL-4052E jest zgodny  
z zasadniczymi wymogami oraz pozostałymi stosownymi  
postanowieniami Dyrektywy 2004/108/EC.  
TRENDnet declara que este TPL-4052E está conforme com  
os requisitos essenciais e outras disposições da Direcꢀva  
2004/108/CE.  
Česky  
[Czech]  
Nederlands  
[Dutch]  
mt  
da  
Dansk  
Malꢀ  
[Danish]  
[Maltese]  
de  
hu  
Deutsch  
Magyar  
[German]  
[Hungarian]  
pl  
Polski  
et  
Eesꢀ  
[Polish]  
[Estonian]  
pt  
Português  
en  
English  
[Portuguese]  
sl  
TRENDnet izjavlja, da je ta TPL-4052E v skladu z bistvenimi  
zahtevami in ostalimi relevantnimi določili direkꢀve  
2004/108/ES.  
TRENDnet týmto vyhlasuje, že TPL-4052E spĺňa základné  
požiadavky a všetky príslušné ustanovenia Smernice  
2004/108/ES.  
TRENDnet vakuuꢁaa täten eꢁä TPL-4052E tyyppinen laite  
on direkꢀivin 2004/108/EY oleellisten vaaꢀmusten ja sitä  
koskevien direkꢀivin muiden ehtojen mukainen.  
Härmed intygar TRENDnet aꢁ denna TPL-4052E står I  
överensstämmelse med de väsentliga egenskapskrav och  
övriga relevanta bestämmelser som framgår av direkꢀv  
2004/108/EG.  
Slovensko  
es  
Español  
[Slovenian]  
[Spanish]  
sk  
Slovensky  
[Slovak]  
el  
Ελληνική  
[Greek]  
Suomi  
[Finnish]  
fr  
Français  
[French]  
sv  
Svenska  
[Swedish]  
it  
Italiano  
[Italian]  
lv  
Latviski  
[Latvian]  
lt  
Šiuo TRENDnet deklaruoja, kad šis TPL-4052E aꢀꢀnka  
esminius reikalavimus ir kitas 2004/108/EB Direktyvos  
nuostatas�  
Lietuvių  
[Lithuanian]  
© Copyright 2013 TRENDnet. All rights reserved.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TPL-4052E User’s Guide  
Warranty  
FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION  
MAINTENANCE OR USE OF TRENDNET’S PRODUCTS.  
Limited Warranty  
TRENDnet warrants its products against defects in material and workmanship, under  
normal use and service, for the following lengths of ꢀme from the date of purchase.  
TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND  
EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT  
EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT,  
IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR  
MODIFY, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY  
ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.  
TPL-4052E – 3 Years Warranty  
AC/DC Power Adapter, Cooling Fan, and Power Supply carry 1 year warranty.  
If a product does not operate as warranted during the applicable warranty period,  
TRENDnet shall reserve the right, at its expense, to repair or replace the defecꢀve  
product or part and deliver an equivalent product or part to the customer. The  
repair/replacement unit’s warranty conꢀnues from the original date of purchase. All  
products that are replaced become the property of TRENDnet. Replacement products  
may be new or recondiꢀoned. TRENDnet does not issue refunds or credit. Please  
contact the point-of-purchase for their return policies.  
TRENDnet shall not be responsible for any soſtware, firmware, informaꢀon, or  
memory data of customer contained in, stored on, or integrated with any products  
returned to TRENDnet pursuant to any warranty.  
There are no user serviceable parts inside the product. Do not remove or aꢁempt to  
service the product by any unauthorized service center. This warranty is voided if (i)  
the product has been modified or repaired by any unauthorized service center, (ii) the  
product was subject to accident, abuse, or improper use (iii) the product was subject  
to condiꢀons more severe than those specified in the manual.  
Warranty service may be obtained by contacꢀng TRENDnet within the applicable  
warranty period and providing a copy of the dated proof of the purchase. Upon  
proper submission of required documentaꢀon a Return Material Authorizaꢀon (RMA)  
number will be issued. An RMA number is required in order to iniꢀate warranty  
service support for all TRENDnet products. Products that are sent to TRENDnet for  
RMA service must have the RMA number marked on the outside of return packages  
and sent to TRENDnet prepaid, insured and packaged appropriately for safe shipment.  
Customers shipping from outside of the USA and Canada are responsible for return  
shipping fees. Customers shipping from outside of the USA are responsible for custom  
charges, including but not limited to, duty, tax, and other fees.  
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW TRENDNET ALSO  
EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN  
CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL,  
INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF  
REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATE, OR  
OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE,  
INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION  
OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR,  
REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT TRENDNET’S OPTION.  
THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY  
PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.  
Governing Law: This Limited Warranty shall be governed by the laws of the state of  
California.  
Some TRENDnet products include soſtware code wriꢁen by third party developers.  
These codes are subject to the GNU General Public License (“GPL”) or GNU Lesser  
General Public License (“LGPL”).  
and look for the desired TRENDnet product to access to the GPL Code or LGPL Code.  
These codes are distributed WITHOUT WARRANTY and are subject to the copyrights  
of the developers. TRENDnet does not provide technical support for these codes.  
lgpl.txt for specific terms of each license.  
WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT OPERATE AS  
WARRANTED ABOVE, THE CUSTOMER’S SOLE REMEDY SHALL BE, AT TRENDNET’S  
OPTION, REPAIR OR REPLACE. THE FOREGOING WARRANTIES AND REMEDIES ARE  
EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,  
EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
TRENDNET NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME  
5/2013  
TPL-4052E User’s Guide V1.1  
© Copyright 2013 TRENDnet. All rights reserved.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tektronix Sprinkler 11801B User Manual
Tiger Games 65 101 User Manual
Timex Clock Radio T121 IB User Manual
Toshiba Car Video System TR 2010E User Manual
Toshiba CRT Television 20A43 User Manual
Toshiba DVD Player SD V392SU User Manual
Triarch Indoor Furnishings 75360 10 User Manual
Viking Refrigerator Refrigerator Drawer User Manual
VocoPro Microphone PA MAN User Manual
Weber Charcoal Grill 55036_022811 User Manual