TRENDnet Network Hardware 4 Port Powerline 500 AV Adapter User Manual |
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Product Overview
Features
Product Overview
TRENDnet’s 4-Port Powerline 500 AV Adapter, model TPL-4052E, uses
an electrical outlet to create a 500 Mbps powerline network. Two
adapters are needed to start a network. Connect network ready TVs,
media players, game consoles, and computers to the four Ethernet
ports. No CD installaꢀon required—encrypted TRENDnet adapters auto-
connect out of the box. This adapter will automaꢀcally connect to other
out of box TRENDnet Powerline AV adapters. No installaꢀon required.
(To add up privacy on top of your network, TRENDnet recommends
using buꢁon pressing sequence to scramble network name instead
leave the key public as set in default.) Power saving mode reduces
up to 80% electric consumpꢀon when network is idle. QoS, Quality
of Service, technology prioriꢀzes video, audio, and online gaming,
smoothing your streaming experience. LED lamps indicate device and
port status for network monitoring and easy troubleshooꢀng. Advanced
AES encrypꢀon secures your network. This adapter is ideal for use in
buildings that interfere with wireless networking signals.
•
•
•
•
•
Compliant with IEEE1901 and HomePlug AV standards
High speed networking over an exisꢀng electrical system
4 x 10/100 Mbps Auto-MDIX Fast ports
One-touch Sync buꢁon networks adapters quickly
Three LED indicators: Power (on/off), Powerline Link (green (best),
amber (beꢁer), red (good), off(no connecꢀon), Ethernet Link
(solid, blinking, off)
TPL-4052E
Package Contents
•
•
Connect one Powerline 500 AV Adapter to the Internet and then
plug in up to 15* addiꢀonal Powerline 500 AV Adapters for instant
connecꢀvity
Share data intensive files, play games, download music and more
at faster data transfer rates
Advanced 128-bit AES encrypꢀon to ensure total network security
Power Save mode reduces electric consumpꢀon by 80%
Network signal transmits up to 300 meters (984ſt.)
Auto QoS support through traffic classificaꢀon and mulꢀple
priority queuing
TPL-4052E package includes:
•
•
•
•
TPL-4052E: 4-Port Powerline 500 AV Adapter
Mulꢀ-language Quick Installaꢀon Guide
CD-ROM (Uꢀlity & User’s Guide)
Network cable (1.5 m / 5 ſt.)
•
•
•
•
© Copyright 2013 TRENDnet. All rights reserved.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Product Overview
•
Opꢀonal management uꢀlity compaꢀble with Windows 8 (32/64-
bit), Windows
* 8 acꢀve adapter can stream data at the same ꢀme. Up to 16 adapters
can be configured in the same network. Addiꢀonal adapters may decrease
network performance. 500Mbps is the maximum theoreꢀcal powerline data
rate. Actual throughput will vary depending on the environment. Networked
Powerline devices must be plugged into power outlets that are on the
same electrical system. GFCI outlets and AFCI circuit breakers may degrade
powerline network signals.
Power (PWR) LED
Powerline (PL) LED
Network 1 ~ 4
Connect network cables
{
from Powerline Adapter
to your computer, game
console, network TV, and
other network devices.
Product informaꢀon on device label
Model Number
Serial Number
Power plug
Network MAC Address
Device Password (DPW)
Hardware version
Plugs directly into an
available power outlet.
Not on power strip�
Firmware version
Reset buꢁon
Resets the unit to factory
defaults.
Sync buꢁon
Synchronize with other
Powerline Adapters.
© Copyright 2013 TRENDnet. All rights reserved.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Product Overview
Push Buꢁons
Diagnosꢀc LEDs
Indicates the device and connecꢀon status
Buꢁon
Acꢀon
Funcꢀon
LED
Color Sequence
Definiꢀon
Device powered on
Iniꢀate Sync/Connecꢀon and generate random
private network name on first adapter (PWR
LED will start blinking).
Green
Solid
Off
PWR
(Power)
Device powered off
N/A
Powerline connected (Best)
Solid
Match the network name on secondary
or addiꢀonal adapter and connect to first
adapter. (PWR LED will start blinking)
Green
Amber
Red
Syncing or Powerline data
transmiꢂng/receiving (Best)
Sync
Push and hold
for 2 seconds
Blinking
Solid
(see Using
the Sync
Buꢁon
Powerline connected (Beꢁer)
Note: To establish connecꢀvity, the secondary
or addiꢀonal Powerline Adapter’s Sync buꢁon
must also be pushed within 2 minutes (120
sec) of pushing the Sync buꢁon of the first
adapter�
Secꢀon for
instrucꢀons)
Powerline data transmiꢂng/receiving
(Beꢁer)
PL
(Powerline)
Blinking
Solid
Powerline connected (Good)
Powerline data transmiꢂng/receiving
(Good)
Blinking
Erases the network name
(All LEDs will turn off and turn back on).
Push/hold for
15 seconds
Powerline is not synced or
connected
Network connecꢀon established
Data transmission is detected
Network standby or no network
connecꢀon
N/A
Green
N/A
Off
Reset device to factory defaults (All LEDs will
turn off and turn back on).
Note: Will reset to the factory default private
network name “HomePlug AV”.
Push/Hold for
1 second only
Solid
Blinking
1-4
Reset
(Fast
Ethernet
Connecꢀon)
Off
Save Mode: The device will automaꢀcally standby to reduce power usage when there
is no network traffic for more than 10~20 minutes. It will automaꢀcally resume back
to full speed service when traffic resumes.
Note: Powerline (PL) LED color indicates the strength and quality of the Powerline
connecꢀon through the electrical system. The following factors may affect the
powerline network’s connecꢀon quality:
•
Noise – Generated by appliances which use your electrical system (e.g.
Microwaves, ovens, hair dryer, irons, dishwashers, etc.). The quality of your
household electrical wiring may also cause addiꢀonal noise on your electrical
system.
•
Distance – Long lengths of electrical wiring through your electrical system
between connected Powerline Adapters.
© Copyright 2013 TRENDnet. All rights reserved.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Product Overview
Applicaꢀon Diagram
Diagram Explanaꢀon:
The first Powerline unit is networked
to a router which is in turn
connected to a modem (typically
supplied by your Internet Service
Provider (ISP)) that provides Internet
connecꢀvity. A second Powerline
Adapter is plugged into a wall power
outlet near a media center and is
providing Internet connecꢀvity to a
game a game console and a Blu-ray
player / media player via Ethernet.
© Copyright 2013 TRENDnet. All rights reserved.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Installing Your Powerline Adapter
Connecꢀng a Powerline Adapter to your router
Installing Your Powerline Adapter
1. Plug the Powerline Adapter into an available wall power outlet near
your router�
Before you install
Note: This will allow devices connected to your powerline network to
access the Internet and other devices connected to your network.
1. Before you proceed with the installaꢀon, verify the following:
•
•
•
Verify that you already have Internet access through your
exisꢀng network.
Verify that you have an available Ethernet port (also known as a
LAN port) on you router.
Verify that you have at least two Powerline Adapters. Two or
more Powerline Adapters are required to create a powerline
network�
2. Connect the included Ethernet cable (also called a network cable)
from the Ethernet port (also called network port) of your Powerline
Adapter to an available Ethernet port (also called LAN port) on your
router�
3. Once the Powerline Adapter is installed and connected to your
router, verify that the Power (PWR) LED is on or blinking and the
Network LED is on or blinking.
Note: The TPL-4052E package only includes a single Powerline
Adapter. Please ensure that your other Powerline Adapter is
HomePlug® AV or IEEE 1901 compliant (e.g. TRENDnet models
TPL-401E, TPL-402E, TPL-405E , TPL-406E , TPL-407E or another
TPL-4052E.)
2. Plan the locaꢀon of where you will install your Powerline Adapters.
•
•
•
Avoid plugging the adapters into power strips, extension cords,
or surge protectors as this may prevent the adapter from
funcꢀoning correctly or degrade performance.
Avoid plugging the adapters into wall power outlets that are
controlled by a light switch to prevent the Powerline Adapter
from being turned off accidentally.
Avoid plugging the adapters into wall power outlets that
are located near appliances that consume a lot of power
(e.g. refrigerators, washers, dryers) as this may degrade
performance�
TPL-4052E
•
•
Make sure there is an available wall power outlet in the room
where the router is installed and also near the router.
Make sure there is an available wall power outlet in the room
where you want to extend network connecꢀvity.
© Copyright 2013 TRENDnet. All rights reserved.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Installing Your Powerline Adapter
Adding adapters to your network
Once you have installed and connected the first Powerline Adapter
to your router, you can easily extend your network to other rooms by
adding addiꢀonal Powerline Adapters.
To extend your network using an addiꢀonal Powerline Adapter:
1. First, make sure the first Powerline Adapter is installed and
connected to your router�
Note: This will allow devices connected to your powerline network to
access the Internet and other devices connected to your network. See
2. Plug in the addiꢀonal Powerline Adapter to an available wall power
outlet in another room near a computer or network device (e.g. game
consoles, network-enabled TVs, network aꢁached storage, network
media server/players, etc.) you want to connect to your network.
3. Connect one end of the included Ethernet cable to the Ethernet
port on your Powerline Adapter and then connect the other end to the
Ethernet port on your computers or another network enabled device.
4. Aſter the addiꢀonal Powerline Adapter is connected and installed to
your computer or network device, wait for the Powerline (PL) LED to
turn on. Aſter the Powerline (PL) LED turns on, verify that the Power
(PWR) LED is on, the Powerline (PL) LED is on or blinking, and the
network LED is on or blinking.
to your network, you can check if the computer(s) or network device(s)
can access the Internet through your powerline network.
Note: To verify that your Powerline Adapters are connected successfully
To install addiꢀonal Powerline Adapters in other rooms, repeat the
steps above for each adapter�
© Copyright 2013 TRENDnet. All rights reserved.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Securing Your Powerline Network
Using the Sync buꢁon
Secure Your Powerline Network
Change your default network name using the Sync buꢁon
Powerline Adapters join powerline network by using network name.
The default network name is “HomePlugAV”. All out-of-the-box
TRENDnet HomePlugAV Powerline Adapters have the same default
network name and can be connected to each other without further
configuraꢀon. To add network security to your network, you can change
your Powerline network name away from the factory default name.
With a private custom network name, no one can connect to your
Powerline network with an out-of-the-box HomePlugAV adapter.
The physical Sync buꢁon on the Powerline Adapter provides an easy
method of changing the network name� The Sync buꢁon generates
a random network name for your powerline network. To create a
customized network name, see “Using the Powerline Uꢀlity” on page
9�
Note: The default network name assigned to TRENDnet Powerline
Adapters is HomePlugAV. Before changing the default network name,
please make sure your Powerline Adapters are already installed and
connected using the default network name.
TRENDnet recommends you change the Powerline network name
away from the factory default name to increase network security. Once
configured, the Powerline network name will be saved. The adapter
can be moved freely within its operaꢀng range without having to
reconfigure the network name. If a mistake is made in the seꢂngs,
the adapter can be reset to the factory default seꢂngs by pressing the
reset Reset buꢁon for 1 second.
There are two ways to change the default network name:
1� (Recommended) Use the physical Sync buꢁon on your
Powerline Adapter to generate a random private network name.
See “Using the Sync Buꢁon” in next secꢀon.
OR
2� Create a customized private network name for your powerline
* If the Powerline Adapter seꢂngs have been changed, the
adapter must be reset to the factory default seꢂngs to be
recognized by Powerline Uꢀlity.
© Copyright 2013 TRENDnet. All rights reserved.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Securing Your Powerline Network
the new network name. All LEDs will turn off and turn back on and the
Powerline (PL) LED will turn on the when adapters are connected.
Changing the network name and associaꢀng two Powerline
Adapters:
Note: Use the Sync buꢁon procedure below if you are connecꢀng
TRENDnet Powerline models TPL-401E, TPL-402E, TPL-405E , TPL-406E ,
TPL-407E or TPL-4052E.
Adding adapters using the Sync buꢁon
1. Verify that all Powerline Adapters are already installed and
connected using the default network name, see “Installing Your
If you have changed the default network name assigned to your
Powerline Adapters, addiꢀonal adapters will not automaꢀcally connect
to your powerline network aſter they are plugged into a wall power
outlet. You have to change the network name on addiꢀonal Powerline
Adapter in order to join your exisꢀng powerline network.
Prepare your adapters:
2. On one of the connected Powerline Adapters, push and hold the
Sync buꢁon for 15 seconds and then release it. All LEDs will turn off and
turn back on. This will erase the current network name assigned to the
first Powerline Adapter.
Note: Once you have completed this step, the other Powerline Adapter
will no longer be able to communicate to this Powerline Adapter.
3. On the other Powerline Adapter, push and hold the Sync buꢁon for
15 seconds then release it. All LEDs will turn off and turn back on. This
will erase the current network name assigned to the second Powerline
Adapter�
Start associaꢀon:
4. Within 2 minutes, push and hold the Sync buꢁon on the first
Powerline Adapter for 2 seconds and then release it. The Power (PWR)
LED will start blinking. This will generate a random network name on
the first Powerline Adapter.
5. Push and hold the Sync buꢁon on the second Powerline Adapter
for 2 seconds and release it. The Power (PWR) LED will start blinking.
This will create a connecꢀon between both Powerline Adapters using
© Copyright 2013 TRENDnet. All rights reserved.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Securing Your Powerline Network
Configuring an addiꢀonal Powerline Adapter to connect and
use the network name of your exisꢀng powerline network:
Using the Powerline Uꢀlity
The Powerline Uꢀlity allows you doing following jobs:
1� Create a customized network name for your powerline network
and apply it to mulꢀple Powerline Adapters at the same ꢀme.
2� View Powerline Adapters connected to your network (using
the MAC address) and the approximate connecꢀon quality and
speed of each Powerline Adapter.
Note: Use the Sync buꢁon procedure below if you are connecꢀng
TRENDnet Powerline models TPL-401E, TPL-402E, TPL-405E , TPL-406E ,
TPL-407E or TPL-4052E.
1� Verify that all exisꢀng Powerline Adapters are already installed and
connected�
3� View and upgrade Powerline Adapter firmware.
Note: Link speed displayed in the uꢀlity of your Powerline
Adapters to another through your electrical system is esꢀmated.
Actual link speed may vary.
Prepare your adapter:
2� Push and hold the Sync buꢁon on the addiꢀonal Powerline Adapter
for 15 seconds and then release it. All LEDs will turn off and turn
back on. This will erase the current network name assigned to the
addiꢀonal Powerline Adapter.
Before installing and using the uꢀlity, please ensure the following:
1. Write down the Device Password (DPW) (16-digit characters
A-Z only) and MAC Address (12-digit characters a-f, A-F, 0-9) of
each Powerline Adapter as this will be required to change the
network name for mulꢀple Powerline Adapters. See “Product
Start associaꢀon:
3� Push and hold the Sync buꢁon on one of the exisꢀng Powerline
Adapters connected to your powerline network for 2 seconds and
then release it. The Power (PWR) LED will start blinking.
2. Make sure your computer in which you are installing the uꢀlity
is connected to your network and your Powerline Adapters are
also connected to your network.
3. If you have changed your network name using the Sync buꢁon
and you are creaꢀng a customized network name, it is required
to reset all powerline devices to factory defaults using the
physical Reset buꢁon on your Powerline Adapter before using
the uꢀlity. See”Push Buꢁons” on page 3.
4� Within 2 minutes, push and hold the Sync buꢁon on the addiꢀonal
Powerline Adapter for 2 seconds and release it. The Power
(PWR) LED will start blinking. This will reconfigure your addiꢀonal
Powerline Adapter to connect and use the network name of your
exisꢀng powerline network. All LEDs will turn off and turn back on
and the Powerline (PL) LED will turn on the adapters are connected.
4. Please ensure that your Powerline Adapters are already
installed and connected and the Ethernet port on each adapter
is connected to a device powered on.
Configure to add addiꢀonal Powerline Adapters to your exisꢀng
powerline network, repeat the steps above for each adapter.
© Copyright 2013 TRENDnet. All rights reserved.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
The installer will check if you have a previous WinPcap uꢀlity.
4. Click OK�
Powerline Uꢀlity System Requirements
•
•
Windows 8 (32/64-bit), Windows 7 (32/64-bit), Windows Vista
(32/64-bit), or Windows XP (32/64-bit)
Microsoſt® .NET Framework 3.5 installed
Soſtware Installaꢀon
1. Insert the included CD-ROM into your computer’s CD-ROM drive.
Note: The Powerline Uꢀlity requires WinPcap as a base applicaꢀon. If this
prompt does not appear, you may already have the WinPcap applicaꢀon
installed. Windows 8 require WinPcap 4.1.3. Windows 7 and older will work
with previous versions of WinPcap. If you have installed a previous version of
WinPcap, please uninstall it manually. And then, start the installaꢀon from the
beginning.
2. At the CD Autorun Prompt window, click Run Autorun.exe �
Note: If the Autorun prompt does not appear automaꢀcally, open the CD
contents and double-click Autorun.exe.
3. At the CD-ROM main menu, click Install Uꢀlity�
5� At the WinPcap installer window, click Next�
© Copyright 2013 TRENDnet. All rights reserved.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
6. Click Yes to allow installaꢀon.
8. In the Installaꢀon Opꢀons window, leave the Automaꢀcally start the
WinPcap driver at boot ꢀme checked and click Install�
7. Review the license agreement and click I Agree�
9. Wait for the WinPcap installaꢀon to complete.
© Copyright 2013 TRENDnet. All rights reserved.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
12. In the License Agreement window, click I Agree, and then click Next.
10. Aſter the process has been completed, click Finish�
13. In the Select Installaꢀon Folder window, click Next�
11. At the TRENDnet Powerline Uꢀlity Setup Wizard, click Next�
14. In the Confirm Installaꢀon window, click Next�
© Copyright 2013 TRENDnet. All rights reserved.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Using the Uꢀlity
Before using the uꢀlity, please ensure the following:
1. Write down the Device Password (DPW) (16-digit characters
A-Z only) and MAC Address (12-digit characters a-f, A-F, 0-9) of
each Powerline Adapter as this will be required to change the
network name for mulꢀple Powerline Adapters. See “Product
2. Make sure the computer in which you are installing the uꢀlity
is connected to your network and your Powerline Adapters are
also connected to your network.
3. If you have changed your network name using the Sync buꢁon
and you are creaꢀng a customized network name, it is required
to reset all powerline devices to defaults using the physical
Reset buꢁon on your Powerline Adapter first before using the
4. Please ensure that your Powerline Adapters are already
installed and connected and the Ethernet port on each adapter
is connected to a device powered on.
15. Wait for the Powerline Uꢀlity installaꢀon to complete. At the
Installaꢀon Complete window, click Close�
Upon compleꢀng the soſtware installaꢀon, a desktop shortcut is
automaꢀcally created. Double-click the icon to start the uꢀlity or
open the uꢀlity if it is already running. Closing the uꢀlity will exit the
applicaꢀon.
You can also launch the uꢀlity from Start Menu.
Start > Programs (or All Programs) > TRENDnet >
TRENDnet Powerline Uꢀlity
© Copyright 2013 TRENDnet. All rights reserved.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Powerline Uꢀlity - Map View
Auto Scan
Auto Scan is selected by default. The
uꢀlity will scan for remote devices in
specific intervals (default: 2 sec, you
can change it from 2 to 60 secs).
Auto scan can be disabled by
deselecꢀng it. Remote adapters can be
scanned manually by clicking the Scan
buꢁon below.
Local Device
All Powerline Adapters connected to
the same network as your computer
will be listed here.
The default device name is main chip
number, followed by the MAC address
and firmware version number. You
can mouse over the header and adjust
column width by clicking and dragging
Network Type
The default network type is public.
When the network name is customized
and changed, it becomes private.
this cursor
.
Remote Devices
These are Powerline Adapters in
remote locaꢀons connected to a
selected local Powerline Adapter on
the electrical system.
Scan
You can mouse over the header and
adjust the column width by clicking
and dragging this cursor to see more
informaꢀon.
Manually scan remote Powerline
devices which has same network name
Enter Password
Manage your device
Highlight a device by
clicking the row and click
buꢁons below
Rename
Add Device
Add remote Powerline Adapter
Enter device DPW here. You can
manage the remote adapter if
only you enter the DPW.
Change device name
to meaningful names
such as “living room”
* DPW (Device Password) is shown on device label
** TPL-4052E has a Power Save Mod. The device seꢂng can only be changed when the device is acꢀve.
To keep remote Powerline Adapter in an acꢀve state, you can power cycle the device or connect it to a
network device, such as a router or a computer.
© Copyright 2013 TRENDnet. All rights reserved.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Rename remote device
(Click and select a remote device and then click Rename buꢁon in Map
Add Device
(Click Add Device buꢁon in Map View)
View)
Enter a meaningful name for easy management
Enter Password
Enter device name and DPW to add an adapter manually
(Click and select a remote device and then click Enter Password buꢁon
in Map View)
Scan
Click Scan buꢁon in Map View to scan other powerline devices
manually.
The device password (DPW) can be found on device label. You have to
enter DPW in order to manage Powerline Adapter remotely.
© Copyright 2013 TRENDnet. All rights reserved.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Powerline Uꢀlity - Detailed View
System Informaꢀon
System Informaꢀon secꢀon shows
this uꢀlity version, your computer
informaꢀon, network adapters
installed on your computer.
Remote Devices
Powerline Adapters in remote locaꢀons
connect to your network shows here�
Show Acꢀve Device(s) Only
Un-check this check box, you can
include all device informaꢀon on
network, even it is not in acꢀve state.
Manage your report
Delete
Save Report
Print Report
Highlight the device by
clicking the row and click status report (Un-select
buꢁons below
Delete the device from
Click this buꢁon
to save above
Click this buꢁon
sending above
auto scan in About secꢀon informaꢀon for later informaꢀon to your
to prevent the deleted
use.
default printer.
device added in again.)
* DPW (Device Password) is shown on device label
© Copyright 2013 TRENDnet. All rights reserved.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Powerline Uꢀlity - Device Setup
Private Network Name
Use Default
This is the network name of your
powerline network. Default is
“HomePlugAV”. When network name
set to “HomePlugAV”, it considered
a public network because very out of
box Powerline Adapter can join this
network. Powerline Adapters connect
to each other only when network
name is the same� Change network
name and make your network private
is recommended to increase your
privacy.
If you don’t remember what network
name you set previously, you can set
the network public. Then set it back to
private later.
Set Local Device
Change network name on device
selected above.
Set Remote Devices
All devices currently connected locally to
your computer or connected remotely
through powerline network will set to
the new network name�
You have to remember your network
name (Private Network Name). It will
be encrypted and save to device. Even
Powerline Uꢀlity cannot read it in plain
text again. When you visit this Private
Seꢂngs again and the Private Network
Name show UnknownNetworkName, it
means the network name is private.
Mulꢀcast Address
Click this buꢁon to synchronize mulꢀcast
address on all adapters on same
powerline network.
© Copyright 2013 TRENDnet. All rights reserved.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Powerline Uꢀlity - Advanced
Select Local Device
This advanced feature supports local devices only. Choose one of
your local device and proceed the advance seꢂng.
Upgrade Firmware
Click this buꢁon to upgrade device firmware.
Reset Device
Cleanup device acꢀve jobs and start fresh again.
Factory Defaults
Clean up all your seꢂngs on adapter. Always click this buꢁon aſter
you upgrade firmware.
Set VLAN Tags
Set VLAN tag for stream idenꢀty
Set TOS Bits
Setup Type-of-Service bits to
differenꢀate packets
© Copyright 2013 TRENDnet. All rights reserved.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Powerline Uꢀlity - Opꢀons
Scan Opꢀons
By default, the Powerline uꢀlity scans
adapters aꢁached to the network every
2 seconds. You can change the scanning
frequency from 2 seconds tup to 60
seconds or stop auto scan. You can then
scan devices manually by clicking Scan
buꢁon in Map View.
© Copyright 2013 TRENDnet. All rights reserved.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Powerline Utility
Powerline Uꢀlity - About
About Powerline Uꢀlity
This Powerline Uꢀlity manages TPL-
4052E and most legacy HomePlug
cerꢀfied Powerline Adapters.
For more informaꢀon, please visit our
website www�trendnet�com
© Copyright 2013 TRENDnet. All rights reserved.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Technical Specifications
Technical Specificaꢀons
Hardware
Standards
LED
Power (PWR)
Powerline (PL) with Connecꢀon Quality
Indicaꢀon
IEEE 1901, HomePlug® AV, IEEE 802.3, IEEE
802.3x, IEEE 802.3u
•
4 x 10/100 Mbps Fast Ethernet Auto-
Interface
•
•
•
•
Best (Green)
Beꢁer (Amber)
Good (Red)
MDIX RJ-45 ports
Power plug
•
o
o
o
A: North America Type B (NEMA 5–15)
EU: Euro Type C (CEE 7/16)
UK : United Kingdom Type G (BS 1363)
No connecꢀon (Off)
Fast Ethernet Connecꢀon (1-4)
•
•
•
Solid
Blinking
Off
2 ~ 50 MHz
Frequency Band
Modulaꢀon
OFDM Symbol Modulaꢀon on link
synchronizaꢀon, 1024/256/64/8 - QAM, QPSK,
BPSK, ROBO Carrier
Buꢁons
Sync, Reset
Dimension (L x W
X H)
A: 105 x 75 x 57 mm (4.1 x 3.0 x 2.2 in.)
EU: 105 x 75 x 73 mm (4.1 x 3.0 x 2.87 in.)
UK: 105 x 75 x 65 mm (4.1 x 3.0 x 2.56 in.)
TDMA, and CSMA/CA
Protocol
Speed
Powerline: up to 500Mbps**
Ethernet: up to 200Mbps with Full Duplex
mode per port
Weight
A: 147 g (5.2 oz)
EU: 170 g (6.0 oz)
UK: 159 g (5.6 oz)
Windows 8 (32/64-bit), Windows 7 (32/64-bit),
Vista (32/64-bit), XP(32/64-bit)
Uꢀlity OS
Compaꢀbility
Power Source
100~240V AC, 50~60Hz
Configuring up to 16 nodes
Acꢀve nodes up to 8 nodes for simultaneous
access
Nodes
Consumpꢀon
Acꢀve mode: 4 Waꢁs (max.)
Standby mode: 0.5 Waꢁs (max.)
Temperature
Operaꢀng: 0° ~ 40°C (32° ~ 104°F)
Storage: -20° ~ 70°C (-4° ~ 158°F)
Up to 300m (984ſt.)
Coverage
128-Bit AES (Advanced Encrypꢀon Standard)
Security
Humidity
Max. 90% (non-condensing)
CE, FCC, HomePlug® AV
Cerꢀficaꢀons
* 8 acꢀve adapter can stream data at the same ꢀme. You can configure up to 16 adapters in the same network. Addiꢀonal adapters may decrease network performance. 500Mbps is the
maximum theoreꢀcal Powerline data rate. Actual throughput will vary depending on environment. Networked Powerline devices need to be plugged into power outlets that are on the
same electrical system. GFCI outlets and AFCI circuit breakers may degrade powerline network signals.
© Copyright 2013 TRENDnet. All rights reserved.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Troubleshooting
Troubleshooꢀng
Please reference the items below if you conꢀnue to experience
difficulty with installing and using your Powerline Adapters.
In addiꢀon to this User’s Guide, you can find help below:
•
(documentaꢀon, downloads, FAQs, how to contact technical
support)
•
•
Power-cycle the Powerline Adapters by disconnecꢀng them from their power
outlets for 15 seconds and then reconnect them.
•
Autorun CD (Quick Installaꢀon Guide)
If the Powerline (PL) LED is red, try plugging the Powerline Adapter into another
available power outlet. The quality of the connecꢀon may be beꢁer in a different
power outlet.
•
•
If you are having issues connecꢀng the Powerline Adapters aſter changing the
network name using the Sync buꢁon or Powerline uꢀlity, reset the Powerline
Adapters to defaults using the physical Reset buꢁon.
Using a pin or paperclip; press and hold the Reset buꢁon for 1 second on each
Powerline Adapter. All LEDs will turn off then turn back on. This will reset the
Powerline Adapters to their default seꢂngs. The default network name is
HomePlugAV.
•
•
The Powerline Adapters can provide beꢁer connecꢀvity and performance when
plugged directly into a power outlet. Connecꢀng the Powerline Adapters to a
power strip or surge protector may degrade or block Powerline signals.
Avoid using the Powerline Adapters on GFI protected outlets and electrical
systems with AFCI circuit breakers. They may degrade or block powerline signals.
•
•
The Powerline Adapters should not be used in areas with excessive heat.
Florescent and incandescent lighꢀng can generate significant powerline
interference�
•
If your building has more than one circuit breaker box, the Powerline Adapter
may not be able to establish connecꢀvity between them. In this case, connect
a Powerline Adapter into a power outlet located on each of the circuit breaker
boxes. Then connect an Ethernet cable between the Powerline Adapters to
bridge the two circuits together.
© Copyright 2013 TRENDnet. All rights reserved.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Appendix
Appendix
Move Powerline Adapters between different overlapping
powerline networks
Overlapping powerline networks
It is possible to create mulꢀple powerline networks on the same
electrical system separated and grouped by different network
network names. The powerline networks will work and communicate
independently of each other which can provide security between
different groups of Powerline Adapters. For example, if you have
five Powerline Adapters (Adapter A, Adapter B, Adapter C, Adapter
D, Adapter E), you can group Adapters A,B, and C together on one
powerline network and group Adapters D and E on a different
powerline network. Each group will use a different network name.
Note: Assuming all Powerline Adapters are TRENDnet Powerline Adapters and for
reference in the diagram and this procedure, the adapters will be labeled Adapter
A, B, C, D, and E. Adapters A, B, and C are currently connect together to form one
powerline network and Adapters D and E form another powerline network. Adapter B
will be disconnected from Adapters A and C and connected to Adapters D and E.
Note: It is recommended that only a maximum of up to 4 powerline networks can
be created per electrical system. Any addiꢀonal powerline networks above the
recommended may result in significant degradaꢀon in powerline performance.
1. Push and hold the Sync buꢁon on Adapter B for 15 seconds and
release it. All LEDs will turn off and turn back on. This will erase the
current network name assigned to Adapter B and disconnect from
Adapter A and Adapter C�
2. Push and hold the Sync buꢁon on Adapter D for 2 seconds and
release it. The Power (PWR) LED will start blinking.
© Copyright 2013 TRENDnet. All rights reserved.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Appendix
3. Within 2 minutes, push and hold the Sync buꢁon on Adapter B for
2 seconds and release it. The Power (PWR) LED will start blinking.
This will establish connecꢀvity between Adapter B, Adapter D, and
Adapter E by reconfiguring the network name of Adapter B to match
the network name of Adapter D and Adapter E. All LEDs will turn off
and turn back on and the Powerline (PL) LED will turn on the when
adapters are connected�
© Copyright 2013 TRENDnet. All rights reserved.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Declaration of Conformity
This transmiꢁer must not be co-located or operaꢀng in conjuncꢀon with any
other antenna or transmiꢁer.
The availability of some specific channels and/or operaꢀonal frequency bands
are country dependent and are firmware programmed at the factory to match
the intended desꢀnaꢀon. The firmware seꢂng is not accessible by the end
user�
Federal Communicaꢀon Commission Interference Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protecꢀon against harmful interference in
a residenꢀal installaꢀon. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instrucꢀons, may cause harmful interference to radio communicaꢀons.
However, there is no guarantee that interference will not occur in a parꢀcular
installaꢀon. If this equipment does cause harmful interference to radio or
television recepꢀon, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the
following measures:
RoHS
This product is RoHS compliant.
•
•
•
Reorient or relocate the receiving antenna.
Increase the separaꢀon between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Europe – EU Declaraꢀon of Conformity
This device complies with the essenꢀal requirements of the Direcꢀve
2004/108/EC, /2006/95/EC and 2009/125/EC:
•
Consult the dealer or an experienced radio/TV technician for help.
FCC Cauꢀon: Any changes or modificaꢀons not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
This device complies with Part 15 of the FCC Rules. Operaꢀon is subject to the
following two condiꢀons: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operaꢀon.
EN55022 : 2010, class B
EN 61000-6-3 : 2007 + A1 :2011
EN 61000-3-2 : 20086 + A1 : 2009 + A2 : 2009,
class A
EN 61000-3-3 : 2008
EN 50412-2-1 :2005, class 1, type 2
EN 60950-1 :2006 + A11 : 2009 + A1 : 2010 + A2 : 2011 : Safety of Informaꢀon Technology Equipment
including electrical business equipment
IMPORTANT NOTE:
FCC Radiaꢀon Exposure Statement:
This equipment complies with FCC radiaꢀon exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
© Copyright 2013 TRENDnet. All rights reserved.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Declaration of Conformity
cs
nl
TRENDnet ꢃmto prohlašuje, že tento TPL-4052E je ve shodě
se základními požadavky a dalšími příslušnými ustanoveními
směrnice 2004/108/ES.
Undertegnede TRENDnet erklærer herved, at følgende
udstyr TPL-4052E overholder de væsentlige krav og øvrige
relevante krav i direkꢀv 2004/108/EF.
Hiermit erklärt TRENDnet, dass sich das Gerät TPL-4052E in
Übereinsꢀmmung mit den grundlegenden Anforderungen
und den übrigen einschlägigen Besꢀmmungen der Richtlinie
2004/108/EG befindet.
Käesolevaga kinnitab TRENDnet seadme TPL-4052E
vastavust direkꢀivi 2004/108/EÜ põhinõuetele ja nimetatud
direkꢀivist tulenevatele teistele asjakohastele sätetele.
Hereby, TRENDnet, declares that this TPL-4052E is in
compliance with the essenꢀal requirements and other
relevant provisions of Direcꢀve 2004/108/EC.
Por medio de la presente TRENDnet declara que el TPL-
4052E cumple con los requisitos esenciales y cualesquiera
otras disposiciones aplicables o exigibles de la Direcꢀva
2004/108/CE.
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ TRENDnet ΔΗΛΩΝΕΙ ΟΤΙ TPL-4052E
ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ
ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 2004/108/ΕΚ.
Par la présente TRENDnet déclare que l’appareil TPL-4052E
est conforme aux exigences essenꢀelles et aux autres
disposiꢀons perꢀnentes de la direcꢀve 2004/108/CE.
Con la presente TRENDnet dichiara che questo TPL-4052E
è conforme ai requisiꢀ essenziali ed alle altre disposizioni
perꢀnenꢀ stabilite dalla direꢂva 2004/108/CE.
Ar šo TRENDnet deklarē, ka TPL-4052E atbilst Direkꢄvas
2004/108/EK būꢀskajām prasībām un ciꢀem ar to
saisꢄtajiem noteikumiem.
Hierbij verklaart TRENDnet dat het toestel TPL-4052E in
overeenstemming is met de essenꢀële eisen en de andere
relevante bepalingen van richtlijn 2004/108/EG.
Hawnhekk, TRENDnet, jiddikjara li dan TPL-4052E
jikkonforma mal-ħꢀġijiet essenzjali u ma provvedimenꢀ
oħrajn relevanꢀ li hemm fid-Dirreꢂva 2004/108/EC.
Alulíroꢁ, TRENDnet nyilatkozom, hogy a TPL-4052E megfelel
a vonatkozó alapvetõ követelményeknek és az 2004/108/EC
irányelv egyéb elõírásainak.
Niniejszym TRENDnet oświadcza, że TPL-4052E jest zgodny
z zasadniczymi wymogami oraz pozostałymi stosownymi
postanowieniami Dyrektywy 2004/108/EC.
TRENDnet declara que este TPL-4052E está conforme com
os requisitos essenciais e outras disposições da Direcꢀva
2004/108/CE.
Česky
[Czech]
Nederlands
[Dutch]
mt
da
Dansk
Malꢀ
[Danish]
[Maltese]
de
hu
Deutsch
Magyar
[German]
[Hungarian]
pl
Polski
et
Eesꢀ
[Polish]
[Estonian]
pt
Português
en
English
[Portuguese]
sl
TRENDnet izjavlja, da je ta TPL-4052E v skladu z bistvenimi
zahtevami in ostalimi relevantnimi določili direkꢀve
2004/108/ES.
TRENDnet týmto vyhlasuje, že TPL-4052E spĺňa základné
požiadavky a všetky príslušné ustanovenia Smernice
2004/108/ES.
TRENDnet vakuuꢁaa täten eꢁä TPL-4052E tyyppinen laite
on direkꢀivin 2004/108/EY oleellisten vaaꢀmusten ja sitä
koskevien direkꢀivin muiden ehtojen mukainen.
Härmed intygar TRENDnet aꢁ denna TPL-4052E står I
överensstämmelse med de väsentliga egenskapskrav och
övriga relevanta bestämmelser som framgår av direkꢀv
2004/108/EG.
Slovensko
es
Español
[Slovenian]
[Spanish]
sk
Slovensky
[Slovak]
el
Ελληνική
[Greek]
fi
Suomi
[Finnish]
fr
Français
[French]
sv
Svenska
[Swedish]
it
Italiano
[Italian]
lv
Latviski
[Latvian]
lt
Šiuo TRENDnet deklaruoja, kad šis TPL-4052E aꢀꢀnka
esminius reikalavimus ir kitas 2004/108/EB Direktyvos
nuostatas�
Lietuvių
[Lithuanian]
© Copyright 2013 TRENDnet. All rights reserved.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
TPL-4052E User’s Guide
Warranty
FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION
MAINTENANCE OR USE OF TRENDNET’S PRODUCTS.
Limited Warranty
TRENDnet warrants its products against defects in material and workmanship, under
normal use and service, for the following lengths of ꢀme from the date of purchase.
TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND
EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT
EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT,
IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR
MODIFY, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY
ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.
•
•
TPL-4052E – 3 Years Warranty
AC/DC Power Adapter, Cooling Fan, and Power Supply carry 1 year warranty.
If a product does not operate as warranted during the applicable warranty period,
TRENDnet shall reserve the right, at its expense, to repair or replace the defecꢀve
product or part and deliver an equivalent product or part to the customer. The
repair/replacement unit’s warranty conꢀnues from the original date of purchase. All
products that are replaced become the property of TRENDnet. Replacement products
may be new or recondiꢀoned. TRENDnet does not issue refunds or credit. Please
contact the point-of-purchase for their return policies.
TRENDnet shall not be responsible for any soſtware, firmware, informaꢀon, or
memory data of customer contained in, stored on, or integrated with any products
returned to TRENDnet pursuant to any warranty.
There are no user serviceable parts inside the product. Do not remove or aꢁempt to
service the product by any unauthorized service center. This warranty is voided if (i)
the product has been modified or repaired by any unauthorized service center, (ii) the
product was subject to accident, abuse, or improper use (iii) the product was subject
to condiꢀons more severe than those specified in the manual.
Warranty service may be obtained by contacꢀng TRENDnet within the applicable
warranty period and providing a copy of the dated proof of the purchase. Upon
proper submission of required documentaꢀon a Return Material Authorizaꢀon (RMA)
number will be issued. An RMA number is required in order to iniꢀate warranty
service support for all TRENDnet products. Products that are sent to TRENDnet for
RMA service must have the RMA number marked on the outside of return packages
and sent to TRENDnet prepaid, insured and packaged appropriately for safe shipment.
Customers shipping from outside of the USA and Canada are responsible for return
shipping fees. Customers shipping from outside of the USA are responsible for custom
charges, including but not limited to, duty, tax, and other fees.
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW TRENDNET ALSO
EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN
CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL,
INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF
REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATE, OR
OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE,
INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION
OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR,
REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT TRENDNET’S OPTION.
THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY
PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
Governing Law: This Limited Warranty shall be governed by the laws of the state of
California.
Some TRENDnet products include soſtware code wriꢁen by third party developers.
These codes are subject to the GNU General Public License (“GPL”) or GNU Lesser
General Public License (“LGPL”).
and look for the desired TRENDnet product to access to the GPL Code or LGPL Code.
These codes are distributed WITHOUT WARRANTY and are subject to the copyrights
of the developers. TRENDnet does not provide technical support for these codes.
lgpl.txt for specific terms of each license.
WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT OPERATE AS
WARRANTED ABOVE, THE CUSTOMER’S SOLE REMEDY SHALL BE, AT TRENDNET’S
OPTION, REPAIR OR REPLACE. THE FOREGOING WARRANTIES AND REMEDIES ARE
EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
TRENDNET NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME
5/2013
TPL-4052E User’s Guide V1.1
© Copyright 2013 TRENDnet. All rights reserved.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|