INWALL RANGE USER MANUAL
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. The user is responsible for fixing the hardware to the surface to ensure safe operation. The fixings must support the
weight of the product – please consult the manual’s specification page for the appropriate weights. Please consult the
relevant construction codes in your region for further information on suitable hardware fixing methods.
6. Some regional construction codes require the use of a secondary method of securing loudspeakers to surfaces to
provide security of a back-up support. A secondary support line should be attached from the safety loop on the rear of
the product to a source point on the wall. Please consult the relevant construction codes in your region.
7. Tannoy will not be held accountable for any damage caused by incorrect installation.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT IDENTIFICATION
IW60 EFX FRONT
Isolation mounts
Isolation mount
Isolation mount
TM
TM
6.5” Dual Concenrtic driver
4” Dual Concentic driver
IW60 EFX TOP
Spring terminal posts
Relay switch socket
Phase switch
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IW63 DC FRONT
Isolation mounts
TM
6.5” Dual Concentric driver
6.5” woofers
Isolation mounts
IW63 DC TOP
Spring terminal posts
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION GUIDELINES
1. Fit the pre-install bracket frame to the 2ft x 4 ft
wooden studs by using suitable fixings (fixings
not supplied). See Fig 1
SAFETY NOTICE: The user is responsible for
fixing the hardware to the surface to ensure safe
operation.
2. Lay the cables
(i) Lay the loudspeaker cable from the amplifier
to the installed pre-mount frame. See point 5 for
connection instructions.
(ii) iw60EFX only: Note that the iw60EFX
features a 12V relay switch which allows the
speaker to toggle between “Cinema” and
“Music” modes if the AV receiver supports this
function. To use this facility you will need to lay
two-core loudspeaker cable from the AV receiver
to the first iw60EFX pre-mount frame then lay
loudspeaker cable from that location to the next
iw60EFX pre mount frame to allow daisy-
chaining. See point 6 for connection
Fig 1.
instructions.
NOTE: The pre-install frame has four 21mm
diameter holes to accommodate cables or even
conduit, if required (two are positioned at the top
and at two are positioned at the bottom). These
holes are blocked off by grommets. Simply
knock out the appropriate grommets and pass
the cables or conduit through the appropriate
holes
Fig 2.
3. Complete the wall, leaving the pre-install
frame exposed. See Fig 2
4. Connect the loudspeaker cables. The positive
terminal on the amplifier channel (marked + or
coloured red) must be connected to the positive
terminal on the loudspeaker (coloured red). The
negative terminal on the amplifier channel
(marked - or coloured black) must be connected
to the negative terminal on the loudspeaker
(coloured black). pre-install frame exposed. See
Fig 3
Fig 3.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
5. iw60EFX only: Note that the iw60EFX features
a 12V relay switch which allows the speaker to
toggle between “Cinema” and “Music” modes if
the AV receiver supports this function.
in phase
Out
of phase
Out of
phase
In phase
Inactive
Cinema Mode: This is the default mode of the
iw60EFX. The two optimally aligned 100mm
(4.00”) Dual Concentric™ drivers generate a
wide and even flow of acoustic energy over a
large area for a diffuse room filling ambience.
The 6.50” Dual Concentric driver is inactive in
Cinema mode.
Inactive
Cinema mode active with the
Cinema mode active with the
phase switch in the DOWN position.
phase switch in the UP position.
The 4” duals are always out-of-phase with each
other in cinema mode. The iw60EFX features a
phase switch which inverts the phase of both the
4.00” drivers. Please refer to the following
diagrams for reference. See Fig 4
Fig 4.
When using left and right iw60EFX speakers, the
phase switch on the left iw60 EFX speaker should
be in the opposite position from the phase switch
on the right iw60 EFX speaker. Please refer to
the following diagram for reference. See Fig 5
Music Mode: This is the direct radiating set up
where the 165mm (6.50”) constant directivity
Dual Concentric™ driver produces a more localised
and focused sound, highlighting the distinct
separation afforded by modern programme material.
The two 4.00” Dual Concentric drivers are inactive
in Music mode. Music mode is selected by using
a 12V trigger from the AV receiver. See Fig 6
LEFT SPEAKER
RIGHT SPEAKER
PHASE SWITCH = DOWN
PHASE SWITCH = UP
Fig 5.
Inactive
Inactive
To setup this relay switching facility, use loudspeaker
cable to connect the + and - relay switch outputs
from the AV receiver to the + and - relay switch
inputs on the iw60EFX, remembering to observe
correct polarity. The relay input switch socket is
a euro-type socket with a loop-through facility,
allowing the relay connections on each iw60EFX
to be daisy-chained. See Fig 7
Activated
Music mode
Fig 6.
Fig 7.
6.Offer the loudspeaker up to the pre-install frame
and fix the four isolation mounts to the pre-install
frame using the supplied fixings then attach the
grille by pushing it onto the baffle. See Fig 8
Fig 8.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DIMENSIONS
DEFINITION IW60 EFX
75.0
[2.95"]
590.0
561.3
[23.23"]
[22.10"]
316.2
[12.45"]
345.0
[13.58"]
94.0
[3.70"]
DEFINITION IW63
75.0
[2.95"]
590.0
561.3
[23.23"]
[22.10"]
316.2
[12.45"]
345.0
[13.58"]
94.0
[3.70"]
7
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SPECIFICATIONS FULL RANGE MODELS
SYSTEM
IW60 EFX
IW63
(1,4)
Frequency Response (-3dB)
110Hz - 23kHz
80Hz - 28kHz
(1,4)
Frequency Range (-10dB)
74Hz - 27kHz
54Hz - 40kHz
(2,4)
System Sensitivity (1W @1m)
Nominal Coverage Angles
90dB (1W = 2.83V for 8 ohms)
91dB (1W = 2.83V for 8 ohms)
90 degrees Conical in music mode
90 degrees Conical
120 degrees Conical
120 degrees H x 90 degrees cinema mode
Coverage Angle (1kHz to 6kHz)
Directivity Factor (Q)
120 degrees
120 degrees Conical
3.5 averaged 1kHz to 6kHz
5.5 averaged 1kHz to 6kHz
3.5 averaged 1kHz to 6kHz
5.5 averaged 1kHz to 6kHz
Directivity Index (Di)
(3)
Power Handling
Average
Programme
Peak
100W
200W
400W
100W
200W
400W
Recommended Amplifier Power
Rated Maximum SPL
200W @ 8 Ohms
110dB
116dB
200W @ 8 Ohms
111dB
117dB
(3)
Average
Peak
Nominal Impedance
Crossover
8 Ohms music mode
4 Ohms cinema mode
8 Ohms
1.6kHz
320Hz, 1.5kHz
Distortion 10% Full Power
(8.94V) 2nd Harmonic 3rd Harmonic
(8.94V) 2nd Harmonic
3rd Harmonic
0.08%
250Hz
1kHz
1.84%
0.34%
0.91%
0.30%
0.61%
0.17%
0.18%
0.89%
1.30%
1.05%
10kHz
0.18%
Distortion 1% Full Power
250Hz
1kHz
(2.83V) 2nd Harmonic 3rd Harmonic
(2.83V) 2nd Harmonic
3rd Harmonic
0.38%
0.19%
0.40%
0.46%
0.35%
0.32%
0.89%
0.90%
0.39%
0.54%
0.61%
0.55%
10kHz
TRANSDUCERS
Music Mode
___
___
1 x 165mm (6.5”) constant directivity Dual Concentric TM
TM
Cinema Mode
2 x 100mm (4.0”) Dual Concentric in dipole configuration
___
Low Frequency
Mid and High Frequency
2 x 165mm (6.5”) woofers
___
TM
1 x 165mm (6.5 constant directivity Dual Concentric
CONSTRUCTION
Enclosure
11.5 litre (net total volume), closed and internally
braced MDF enclosure
11.5 litre, closed and internally braced MDF enclosure
Finish
Textured black paint
Textured black paint
White powder coated perforated steel grille, foam behind
White powder coated perforated steel grille, foam behind
Connectors
Controls
Gold plated spring terminals
Gold plated spring terminals
___
Mode selection input (12VDC relay activated via Dinkle connector
Polarity switch)
Dimensions (H x W x D)
590mm x 345mm x 94mm
(23.23” x 13.58” x 3.70”)
590mm x 345mm x 94mm
(23.23” x 13.58” x 3.70”)
9.5kg
10.5kg
Weight
Accessories
Installation kit required (not included)
Installation kit required (not included)
Notes
(1) Average over stated bandwidth. Measured in an IEC bafflle in an Anechoic Chamber
(2) Unweighted Pink noise input, measured at 1m on axis
(3) Long term power handling capacity as defined in EIA - 426B test
(4) Music Mode
(5) Cinema mode. For music mode refer to iW63 data
A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com. Tannoy operates a policy of continuous research and development.
The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY STATEMENT
No maintenance of the Definition loudspeaker is necessary.
All of our products have been produced and tested with care and precision to give first-class service.
All passive components are guaranteed for a period of five years from the date of purchase from an authorised Tannoy dealer
subject to the absence or evidence of misuse, overload, or accidental damage.
All active and electronic components are guaranteed for a period of one year from the date of purchase from an authorised
Tannoy dealer subject to the absence of, or evidence of, misuse, overload or accidental damage.
If at any time during this warranty period the equipment proves to be defective for any reason other than accident, misuse,
neglect, unauthorised modification or fair wear and tear, we will repair any such manufacturing defect or, at our option,
replace it without charge for labour, parts or return carriage.
If you suspect a problem with a Tannoy product then, in the first instance, discuss it with your Tannoy dealer. If you require
further assistance then we ask that you deal directly with your local Tannoy distributor. If you cannot locate your distributor
please contact Customer Services, Tannoy Ltd at the address given below.
Customer Services, Tannoy Ltd., Rosehall Industrial Estate, Coatbridge, Strathclyde ML5 4TF, Scotland
Telephone:
Fax:
01236 420199
(National)
+44 1236 420199
01236 428230
(International)
(National)
+44 1236 428230
(International)
E-mail:
DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION
Our policy commits us to incorporating improvements to our products through continuous research
and development. Please confirm current specifications for critical applications with your supplier.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
DECLARATION OF CONFORMITY
The following apparatus is manufactured in the UK at Tannoy Ltd of Rosehall Industrial Estate, Coatbridge, Scotland,
ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards
and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and constructed such that
electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment
and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity to
electromagnetic disturbance to enable operation as specified and intended.
Details of the Apparatus:
Tannoy Contractor Loudspeaker
Model Number: Definition Install
EMCi6
Associated Technical File:
Applicable Standards:
EN 50081-1 Emission
EN 50082-1 Immunity
Signed:
Position:
Director of Engineering (Professional)
Date: 18th Oct. 07
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Tannoy North America
Tannoy Deutschland
Tannoy France
T: 00 1 (519) 745 1158
Download from Www.Somanuals.com. All Manuals Search And Download.
|