TOA Electronics Music Mixer M 9000 User Manual

DIGITAL MATRIX MIXER  
M-9000  
Ambient Noise Control— automatically increase or reduce  
output levels in response to changes in ambient noise.  
DESCRIPTION  
The TOA M-9000 Series Digital Matrix Mixer features a  
compact design that fits in a two rack space package. The  
versatile new Mixer is ideal for multi-zone paging, music  
distribution and room-combining applications.  
Multi-function Display allows programming and operation  
without a PC.  
Rack-mount Kit Included (2RU)  
The M-9000 includes eight module ports allowing designers to  
easily configure custom systems with up to eight mic/line inputs  
and eight outputs. The M-9000 chassis has two channels of  
built-in digital signal processing (DSP) with ten band parametric  
EQ, compressor, eight level ducking and more. Input and  
output modules provide additional DSP.  
Two discrete operation modes, "Mixer" and "Matrix", allow the  
M-9000 to be used in both simple mixing and complex multi-  
zone paging applications. Versatile features include telephone  
zone paging, automatic microphone mixing and ambient noise  
control.  
Modules include the D-001T dual channel mic/line input  
module, T-001T dual channel line output module, ZP-001T  
telephone access zone paging module, C-001T control  
expansion module, and AN-001T Ambient Noise Control  
module. Accessories include the AN-9001 ceiling/wall-mount  
microphone, ZM-9001 and ZM-9002 remote panels, and  
SS-9001 4-zone speaker selector.  
Flexible Remote Control  
Two Remote Volume ControlTerminals  
• Assignable to any input or output channel  
• Control with 10k ohm linear potentiometer, 0-10 VDC or optional  
ZM-9001/ZM-9002 remote panels  
• Assign remote volume control to background music (Priority 8)  
inputs without affecting paging input volume  
Four Control Inputs (expandable to twelve with C-001T module)–  
programmable to activate Memory, Volume Up/Down, Mute, Power On/Off,  
Emergency Mute  
Four Control Outputs (expandable to twelve with C-001T module) –  
programmable to activate external relays synchronized with Memory,  
Channel On/Off and Power On/Off  
RS-232 Port  
• Control protocol available for external devices (see protocol for  
controllable parameters)  
• AMX and Crestron control modules available  
Additional Features  
Software Utility for saving unit parameters to PC,updating unit firmware,  
virtual control activation and status indication  
MS Excel ProgrammingTemplates – use Microsoft(R) Excel for off-site  
programming  
Keylock Security sets password-protected access to Input,  
Output, Utility & Power functions  
SYSTEM FEATURES  
Input and Output Metering (D-001T module(s) required for input  
metering)  
Modular Digital Matrix Mixer for a multitude of applications  
including audio-visual, zone paging, room combining and  
many more.  
Alphanumeric Channel and Memory Naming  
Power On Memory sets the Event/Scene selected when unit powers up  
Detachable AC Cable  
Dual Modes (MIXER and MATRIX) — two separate feature  
sets to suit both simple mixing and complex multi-zone  
distribution applications.  
Easy to Configure and Operate  
Exceptional Audio Quality  
24-bit, 48 kHz sampling  
Low Distortion - 0.008%  
Rear View  
482  
466  
420  
Modular System— up to 8 mic/line inputs and 8 outputs.  
Dual Channel Digital Signal Processor (DSP):  
10-Band Parametric EQ  
High and Low Pass Filters  
Compressor  
Loudness Contour  
Front View  
353  
335  
Bass and Treble  
14  
Delay (MIXER mode)  
TOA Speaker EQ Presets  
Additional DSP included on D-001T and T-001T modules  
Telephone Zone Paging— access up to eight zones with  
optional ZP-001T module  
Side View  
unit: mm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-9001  
Speaker Selector  
ZM-9001  
Remote Panel  
The SS-9001 is a speaker selector used with the ZP-001T zone paging  
module. It outputs 2 input signals to 4 different zones.  
The ZM-9001 is a remote control switch panel used with the M-9000. It  
provides an additional 6 control inputs of amplifier expansion, and can be  
mounted in an American standard 1-gang electrical box in the wall.  
Power Source  
Supplied from the optional AD-246 AC adapter or an  
external 24 V DC/200 mA power supply.  
Applicable Cable  
Line Resistance  
Terminal  
Single conductor shielded cable  
Under 50 (per line)  
M3 screw terminal, distance between barriers: 7.62 mm  
Current Consumption  
Control Signal  
120 mA  
No-voltage make contact nput (polarized),  
open voltage: 24 V DC, short-circuit current: 3 mA  
Operating Temperature  
Finish  
Dimensions  
Weight  
-10°C to +40°C  
Control Power  
Speaker Terminal  
Control Terminal  
Operating Temperature  
Finish  
Under 240 W (70 V line)  
Removable terminal block (2 pins)  
Removable terminal block (10 pins)  
-10°C to +40°C  
Case: Surface-treated steel plate  
112 (W) × 197 (H) × 30 (D) mm  
530 g  
Surface-treated steel plate, white, paint  
72 (W) × 127 (H) × 45 (D) mm  
170 g  
Accessory  
Box mounting screw × 2, Panel mounting screw × 2  
Note: Since no electrical box is supplied with the unit, prepare it separately.  
Dimensions  
Weight  
72  
33  
45  
37  
Accessory  
Removable terminal plug (2 pins) × 6, Removable terminal  
plug (10 pins) × 1, Cord clamp × 1, Mounting screw × 4  
32.6  
Option  
AC adapter: AD-246  
6
Front view  
without panel  
Unit: mm  
1-gang electrical box  
(not supplied)  
38  
42  
46 – 50  
Figure when mounted  
Dimensions of mounting opening  
1
18  
70  
112  
18  
If the opening is too small or too large, the  
ZM-9001 cannot be mounted in the wall.  
Be sure to make an opening with  
30  
Unit: mm  
dimensions given above when mounting.  
Ambient Noise Sensing  
Microphone  
AN-9001  
ZM-9002  
Remote Panel  
The ZM-9002 is a remote control switch/volume panel used with the  
M-9000. It adds 4 amplifier control inputs and 1 remote volume control,  
and can be mounted in an American Standard 1-gang electrical box in  
the wall.  
The AN-9001 is an electret condenser microphone designed for ambient  
noise sensing. It is used in conjunction with the AN-001T Ambient Noise  
control module in the M-9000. It can be mounted in an American  
Standard 1-gang electrical box in the ceiling or wall.  
Applicable Cable  
Line Resistance  
Terminal  
Operating Temperature  
Finish  
Dimensions  
Weight  
Accessory  
Single conductor shielded cable  
Under 50 (per line)  
M3 screw terminal, distance between barriers: 7.62 mm  
Type  
Electret condenser microphone  
14-26 V DC  
Phantom Power  
Current Consumption  
Directivity  
7 mA (at 24 V DC)  
-10°C to +40°C  
Omnidirectional (hemispherical)  
Surface-treated steel plate, white, paint  
72 (W) × 127 (H) × 56 (D) mm  
170 g  
Impedance  
200 Ω  
Rated Sensitivity  
Frequency Response  
Output Terminal  
Operating Temperature  
Finish  
-5 dB (1 kHz, 0 dB = 1 V/Pa)  
100-10,000 Hz  
Box mounting screw × 2, Panel mounting screw × 2  
Removable terminal block (3 pins)  
-10°C to +40°C  
Panel: ABS resin, white  
Note: Since no electrical box is supplied with the unit, prepare it separately.  
Frame, Case: Surface-treated steel plate  
72  
33  
56  
37  
Dimensions  
Weight  
ø130 × 37 (D) mm  
32.6  
170 g  
Accessory  
Removable terminal plug (3 pins) × 1,  
Box mounting screw (No.6-32UNC x 30) × 2,  
Box mounting screw (M4 x 30) × 2  
Option  
9000 series plug-in module: AN-001T  
Note: Since no electrical box is supplied with the unit, prepare it separately.  
Front View  
without panel  
6
Unit: mm  
1-gang electrical box  
(not supplied)  
38  
42  
31  
37  
46 – 50  
Figure when mounted  
Dimensions of mounting opening  
1-gang electrical box  
(not supplied)  
If the opening is too small or too large,  
the ZM-9002 cannot be mounted in the  
wall. Be sure to make an opening with  
dimensions given above when mounting.  
38  
42  
46 – 50  
Figure when  
mounted  
Dimensions of mounting  
opening  
If the opening is too small or  
too large, the AN-9001  
cannot be mounted in the  
ceiling or wall. Be sure to  
make an opening with  
dimensions given above  
when mounting.  
70  
Front view  
without panel  
Unit: mm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dual Line Output Expansion  
Dual Mic/Line Input  
T-001T Module with DSP  
D-001TModule with DSP  
The T-001T is a plug-in module designed for use with the M-9000  
and provide two independent balanced outputs. It can drive load  
of 600up to +16dB. It can process effect for TONE/EQ/  
COMPRESSOR to two inputs independently.  
The D-001T is a plug-in module designed for use with the M-9000 and  
can provide two independent balanced inputs. The D-001T can handle  
signals ranging from microphone level to line level by controlling their  
input sensitivity in 9 increments from -60dB to -10dB.  
Phantom power (+24V) can be supplied for condenser microphone use.  
The D-001T can process effect for TONE/EQ/COMPRESSOR to two  
inputs independently.  
Power Source  
Current Consumption  
Output  
+24 V DC, -24 V DC, +6 V DC  
35 mA (at +24 V DC), 35 mA (at -24 V DC), 60 mA (at +6 V DC)  
2 channels, max. +20 dB* (at 10 kload), 600 ,  
electronically-balanced, removable terminal block (3 pins)  
Power Source  
Current Consumption  
Input  
+24 V DC, -24 V DC, +6 V DC  
Frequency Response  
20-20,000 Hz, +1, -3 dB  
20 mA (at +24 V DC), 20 mA (at -24 V DC), 60 mA (at +6 V DC)  
Total Harmonic Distortion + N 0.005% (at 1 kHz, 20 – 20,000 Hz BPF, 5 V output, 10 kload)  
S/N Ratio  
2 channels, 3 k(when the phantom power is ON)/  
10 k(when the phantom power is OFF),  
electronically-balanced, removable terminal block (3 pins)  
Over 73 dB (at 20 – 20,000 Hz BPF )  
Under -91 dB (at 20 – 20,000 Hz BPF, VOL: -70 dB)  
Over 87 dB (at 20 kHz)  
Residual Noise  
Crosstalk  
D/A Converter  
Sampling Frequency  
Tone Control  
Input Sensitivity  
Frequency Response  
-60, -54, -48, -42, -36, -30, -24, -18, -10 dB* (selectable)  
20 – 20,000 Hz, +1, -3 dB  
24 bit ∆∑DAC  
48 kHz  
Total Harmonic Distortion + N 0.008% (at 1 kHz, 20-20,000 Hz BPF, Input sensitivity: -10 dB)  
Input Equivalent Noise  
S/N Ratio  
Crosstalk  
Under -112 dB (at 20 – 20,000 Hz BPF, Input short, Input sensitivity: -60 dB)  
Over 73 dB (at 20 – 20,000 Hz BPF, Input short, Input sensitivity: -10 dB)  
Over 75 dB (at 20 kHz, Input sensitivity: -10 dB)  
Over 62 dB (at 1 kHz, Input sensitivity: -60 dB)  
24 bit ∆∑ADC  
Bass: 12 dB (at 100 Hz), Treble: 12 dB (at 10 kHz)  
Parametric Equalizer  
10 bands, Frequency: 20-20,000 Hz, 31 steps,  
Variable range: 12 dB, Q: 0.3-5  
CMRR  
Speaker Equalizer  
High-pass Filter  
Low-pass Filter  
Compressor  
Delay  
Operating Temperature  
Finish  
Dimensions  
Weight  
15 (compatible with TOA speakers only)  
-12 dB/oct, Variable frequency range: 20 – 400 Hz, 14 steps  
-12 dB/oct, Variable frequency range: 4,000 – 20,000 Hz, 8 steps  
Depth: 1-5  
A/D Converter  
Sampling Frequency  
Tone Control  
48 kHz  
Bass: 12 dB (at 100 Hz), Treble: 12 dB (at 10 kHz)  
Parametric Equalizer  
10 bands, Frequency: 20 – 20,000 Hz, 31 steps,  
Variable range: 12 dB, Q: 0.3-5  
0-40 ms (1 ms step), maximum 40 ms (CH 1 + CH2), mixer mode only  
-10°C to +40°C  
Panel: Aluminum, hair-line  
High-pass Filter  
Low-pass Filter  
Compressor  
Phantom Power  
Operating Temperature  
Finish  
-12 dB/oct, Variable frequency range: 20 – 400 Hz, 14 steps  
-12 dB/oct, Variable frequency range: 4,000 – 20,000 Hz, 8 steps  
35 (W) × 78 (H) × 91.5 (D) mm  
82 g  
Depth: 1 – 5  
+24 V DC  
Accessory  
*0 dB = 1 V  
Removable terminal plug (3 pins) × 2, Module mounting screw × 2  
-10°C to +40°C  
Panel: Aluminum, hair-line  
Dimensions  
Weight  
35 (W) × 78 (H) × 91.5 (D) mm  
82 g  
Input/Output Control  
Module  
Accessory  
*0 dB = 1 V  
Removable terminal plug (3 pins) × 2, Module mounting screw × 2  
C-001T  
The C-001T is Control I/O expansion module designed for use with the  
M-9000 and can provide up to 8 channels each of input and output  
expansion. Since the main unit has 4 preinstalled inputs and outputs  
each, the control input and output can be expanded to up to 12  
channels each when the C-001T is used.  
Ambient Noise  
AN-001TController Module  
The AN-001T is a plug-in module of 2-channel ambient noise detector  
designed for use with the M-9000.  
Power Source  
Current Consumption  
Control Input  
6 V DC  
15 mA  
It automatically adjusts the output volume in response to the change of  
ambient noise level.The AN-001T can handle input signals from microphone  
level (-60dB) to line level (-10dB) by controlling the gain in 9 steps.  
Phantom power (+24V) can be supplied for condenser microphone use.  
8 channels, open voltage: 3.3 V DC, short-circuit  
current: under 1 mA, removable terminal block (9 pins)  
Control Output  
8 channels, open collector output, withstand voltage: 27 V DC,  
control current: max. 50 mA, removable terminal block (9 pins)  
Operating Temperature  
Finish  
Dimensions  
Weight  
-10°C to +40°C  
Panal: Aluminum, hair-line  
Power Source  
Current Consumption  
Input  
+24 V DC, -24 V DC, +6 V DC  
20 mA (at +24 V DC), 20 mA (at -24 V DC), 60 mA (at +6 V DC)  
35 (W) × 78 (H) × 91.5 (D) mm  
62 g  
Sensor input (Ambient noise sensor microphone input):  
2 channels, 3 k(when the phantom power is ON)/10 kΩ  
(when the phantom power is OFF), electronically-balanced,  
removable terminal block (3 pins)  
Accessory  
Removable terminal plug (9 pins) × 2, Module mounting screw × 2  
Input Sensitivity  
Phantom Power  
A/D Converter  
Sampling Frequency  
Ambient Noise Control  
Function  
-60, -54, -48, -42, -36, -30, -24, -18, -10 dB* (selectable)  
+24 V DC  
24 bit ∆∑ADC  
48 kHz  
Telephone Zone  
Paging Module  
ZP-001T  
Sensor input reference level adjustment function  
Maximum output signal level control: -15 to 0 dB  
Minimum output signal level control: -18 to -3 dB  
The ZP-001T is a zone paging module designed for use with the M-9000  
and functions as interface to connect the M-9000 to an analog PABX,  
allowing zone paging to be initiated from the PABX. There are two  
operation modes: ring signal and paging port modes.  
Sample time setting: 10 s, 15 s, 20 s, 30 s, 1 min, 2 min, 3 min, 5 min  
Gain ratio setting (Ambient noise: Output signal level):  
6:3, 5:3, 4:3, 3:3, 3:4, 3:5, 3:6, 6:-3, 5:-3, 4:-3, 3:-3, 3:-4, 3:-5, 3:-6,  
Operating Temperature  
Finish  
-10°C to +40°C  
Panel: Aluminum, hair-line  
Broadcast can be initiated regardless of operation mode.  
Dimensions  
Weight  
Accessory  
Option  
35 (W) × 78 (H) × 91.5 (D) mm  
82 g  
Power Source  
+24 V DC, +6 V DC  
Current Consumption  
Number of Line  
Type of Selectable Signal  
Signaling System  
TEL Line  
38 mA (at +24 V DC), 18 mA (at +6 V DC)  
1 line  
Removable terminal plug (3 pins) × 2, Module mounting screw × 2  
Ceiling mount microphone: AN-9001  
DTMF signal  
*0 dB = 1 V  
Loop-Start (or Ground-Start, selectable)  
0 dB, 600 , balanced, transformer-isolated, loop voltage:  
24 V DC or more which should be supplied from the PABX, RJ11 connector  
Paging Input  
Control Input  
Control Output  
0 dB, 600, balanced, transformer-isolated audio input,  
removable terminal block (4 pins)  
1 channel, no-voltage make contact, open voltage: 5 V DC,  
short-circuit current: 0.5 mA, removable terminal block (4 pins)  
4 channels, open collector output (isolated), withstand voltage: 35 V DC,  
control current: max. 50 mA, removable terminal block (4 pins)  
Operating Temperature  
Finish  
-10°C to +40°C  
Pael: Aluminum, hair-line  
Dimensions  
Weight  
35 (W) × 78 (H) × 91.5 (D) mm  
153 g  
Accessory  
Removable terminal plug (4 pins) × 3, Module mounting screw × 2  
TOA Corporation  
Specifications are subject to change without notice.  
Printed in Japan (0612) 833-52-377-40 u  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson MP3 Player PDP2860 User Manual
Toshiba Cash Register MA 71 User Manual
Toshiba Marine Radio PORTG R930 User Manual
Toshiba Printer B SX4T QQ User Manual
Trango Broadband Network Router Access5830 User Manual
Tripp Lite Computer Accessories NB1150BKTAB User Manual
VTech Cordless Telephone CS6328 2 User Manual
VTech CRT Television VT181CH User Manual
Wayne Dalton Medical Alarms 255081 User Manual
Wayne Water Pump 320702 001 User Manual