TDK Network Card iQP48070A033V User Manual

Product Brief: Powereta™ – Single Output High Current Double-P Quarter Brick  
Powereta™ iQP Series Double-P Quarter Bricks  
48V Input, 3.3V/70A and 2.5V/80A Output  
The Powereta™ iQP Series offers an industry standard extra  
output pins (Double-P) quarter brick high current power module  
with true useable output power. Its 89% to 91.5% full load  
efficiency and superior thermal performance make the Powereta™  
Series of power modules ideally suited for tight space and power-  
hungry applications in demanding thermal environments. This  
rugged building block is designed to serve as the core of your high  
reliability system. A wide output voltage trim range, -20 to +10%,  
and remote sensing are standard features enhancing versatility.  
TDK Innoveta Base  
Product Code  
iQP48070A033V  
Input  
Voltage  
36-75V  
Output  
Voltage  
3.3V  
Output  
Current  
70A  
Efficiency  
70%Load  
92.5%  
Efficiency  
100%Load  
91.5%  
Features  
RoHS Compliant  
Standard Double-P Quarter Brick Pinout  
Size: 2.28” × 1.45” × 0.5”  
Up to 80A of output current  
iQP48080A025V  
36-75V  
2.5V  
80A  
90.5%  
89%  
Power density: up to 140W / in3  
Maximum efficiency – up to 93.5%  
Full load efficiency: 89% to 91.5%  
Output power – up to 231W in high  
ambient temperature, low airflow  
environments with minimal derating  
Wide output voltage trim range  
Industry standard output voltage trim  
Basic insulation – 1500Vdc  
Typical Performance  
Input Characteristics  
Operating input range  
Transient input voltage  
Turn-on voltage  
Turn-off voltage  
Maximum input current  
36-75V  
100V  
34.4V  
32.3V  
8 A  
100mS max  
Input 0-75V, Io,max  
Output Characteristics  
Output voltage tolerance  
+/- 3.3% max  
Over line, load, and  
temp to end of life  
Io,max  
Over rated input  
Over rated load  
On/Off to 90% Vo  
%Vo,nom  
20MHz bandwidth  
Load step 25% of  
Io,max  
Choice of remote on/off configuration  
Remote sense  
Constant switching frequency  
Latched output over-voltage protection  
Auto-recovery full protections:  
Efficiency  
89% to 91.5%  
1 mV  
Line regulation  
Load regulation  
Start-up time  
Output voltage adjustment  
Output ripple  
Dynamic response  
Transient voltage  
Recovery time  
1 mV  
25 ms  
80%-110%  
25 - 40 mVp-p  
o Input under and over voltage  
o Output over-current  
o Output short circuit  
o Thermal limit  
150 – 200 mV  
500 - 650 µS  
270 kHz  
slew rate =0.1A/us  
Ripple frequency  
Fixed  
Protection  
Output over-current  
Short circuit  
110% of Io,rated  
Continuous  
protection  
121% of Vout,nom  
126C  
Auto-recovery hiccup  
Auto-recovery hiccup  
UL 60950 (US and Canada), VDE 0805,  
CB scheme (IEC950) Safety markings  
and CE Mark (EN60950)  
Output over-voltage  
Thermal shutdown  
Latching  
Auto recovery with  
hysteresis  
Optional 0.110”, 0.145”, 0.180” pin length  
Optional non-latching OVP protection  
EMI: CISPR 22 A or B with external filter  
Multiple patents pending  
Environmental  
Operating temperature, Tc  
-40C to 119C  
See full datasheet  
ISO9000 certified manufacturing facilities  
(877) 498-0099  
©2006 TDK Innoveta Inc.  
1/2  
iQP 2.5V to 3.3V Product Brief 4/20/2006  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam Car Video System HD R1 User Manual
Tektronix All in One Printer 740 User Manual
Topfield Satellite TV System TF 6000 PVR User Manual
Toshiba Cash Register MA 215 User Manual
Tripp Lite Network Cables N001 003 BK R User Manual
Tripp Lite Surge Protector LS604WM User Manual
Troy Bilt Snow Blower 42021 User Manual
Velodyne Acoustics Speaker VA 12 15X User Manual
Vulcan Hart Oven VCG10H ML 126836 VCG10F ML 126837 VCG20H ML 126838 User Manual
Wagner SprayTech Paint Sprayer W 867 E User Manual