Tannoy Portable Speaker DC6i User Manual

Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 1  
Definition Install DC6i  
Product Description  
Features  
• 150mm (6.00”) high sensitivity, point source and  
constant directivity Dual Concentric™ drive unit  
The Definition Install DC6i has been designed around the unique Tannoy Dual Concentric™  
drive unit to bring class leading performance to a wide range of installation applications;  
from media rooms to home theatre and boardrooms through to high end marine interiors  
these loudspeakers deliver class leading accuracy, sensitivity and dynamics.  
• Constant time delay over the frequency spectrum  
• Exceptional transient performance  
Characteristic of the Dual Concentric™ design is a very wide 'sweet spot' with an  
exceptionally even response throughout the listening area, as well as an extraordinary  
transient response; reasons enough for this phase accurate Tannoy designed drive unit to  
have been the choice of professional studio engineers all over the world for many years.  
• 90 degree conical dispersion  
• Superior harmonic alignment  
• Natural, clean and integrated sound  
• Enhanced intelligibility, sound staging and dynamics  
• Recommended amplifier power 100 to 200W @ 8 Ohms  
• Sensitivity 90dB (1W = 2.83V for 8 Ohms)  
• Maximum SPL 110dB average  
The Dual Concentric™ is effectively two drivers properly merged into one where, unlike  
ordinary drive units, the high frequency unit is positioned on the back of the low frequency  
driver. As a result they are on same axis, so ensuring that sound energy is effectively  
propagated from the same point and delivered through the centre of the low frequency cone  
as true point source. Such integration optimises reproduction quality by providing a constant  
time delay over the frequency spectrum, exceptional transient performance, wide dispersion  
and superior harmonic alignment; all of which delivers to the listening position a natural,  
clean and integrated sound with greatly enhanced intelligibility, sound staging and dynamics.  
• Rugged construction MDF enclosure, vented,  
internally braced and finished with textured black paint  
• Multiple hanging options  
This compact MDF cabinet is vented and rigidly constructed with extensive bracing to be  
acoustically inert. The speaker is designed to be hidden within a custom designed  
installation; mounted on wall either behind the screen or acoustically transparent decorative  
panels with no appreciable loss of performance. The unit can be mounted either horizontally  
or vertically using the integral keyhole mounts and the supplied wall plate.  
Applications  
Designed to be used in left, centre or right locations the DC6i is capable of explosive  
dynamics with stunning detail in both music and movie application in vast array of listening  
and viewing environments.  
• Media rooms  
• Home theatre  
• Boardrooms  
• High end marine interiors  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Definition Install DC6i data file // issue 1.06 // 15.01.08  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 3  
Definition Install DC6i  
PERFORMANCE MEASUREMENTS  
1m on-axis frequency response  
100  
90  
80  
70  
60  
50  
10  
100  
1000  
10000  
100000  
ANECHOIC  
FREQUENCY  
RESPONSE  
frequency (Hz)  
Impedance vs frequency  
30  
25  
20  
15  
10  
5
0
10  
100  
1000  
10000  
frequency (Hz)  
IMPEDANCE  
Horizontal off-axis response  
100  
90  
80  
70  
60  
50  
0 deg  
10 deg  
20deg  
30deg  
40deg  
10  
100  
1000  
10000  
100000  
OFF AXIS  
RESPONSE  
frequency (Hz)  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Definition Install DC6i data file // issue 1.06 // 15.01.08  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 4  
Definition Install DC6i  
PERFORMANCE MEASUREMENTS  
Vertical off-axis response  
100  
90  
80  
70  
60  
50  
0 deg  
10 deg  
20deg  
30deg  
40deg  
10  
100  
1000  
frequency (Hz)  
10000  
100000  
OFF AXIS  
RESPONSE  
Beamwidth vs Frequency  
360  
330  
300  
270  
240  
210  
180  
150  
120  
90  
60  
30  
0
100  
1000  
10000  
frequency (Hz)  
BEAMWIDTH  
DI vs Frequency  
100  
10  
1
Q
100  
1000  
10000  
frequency (Hz)  
DIRECTIVITY INDEX  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 5  
Definition Install DC6i  
PERFORMANCE MEASUREMENTS POLAR PLOTS (1/3 OCTAVE)  
10 Hz  
125Hz  
160Hz  
20 Hz  
250Hz  
315Hz  
400Hz  
500Hz  
0
0
330  
0
-12  
-24  
30  
330  
0
-12  
-24  
30  
300  
60  
300  
60  
-36  
-48  
-36  
-48  
270  
90  
270  
90  
630HHzz  
800Hz
1.0kHz  
1.25kHz
1.6 kHz  
2.0kHz  
2.5 kHz  
3.15 kHz  
0
0
330  
0
30  
330  
0
30  
-12  
-12  
300  
60  
300  
60  
-24  
-24  
-36  
-48  
-36  
-48  
270  
90  
270  
90  
4.0kHz  
5.0kHz  
6.3kHz  
8.0kHz  
1.0kHz  
12.5kHz  
16kHz  
0
0
2.0kHz  
330  
0
30  
330  
0
-12  
-24  
30  
-12  
-24  
300  
60  
300  
60  
-36  
-48  
-36  
-48  
270  
90  
270  
90  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Definition Install DC6i data file // issue 1.06 // 15.01.08  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 6  
Definition Install DC6i  
PERFORMANCE MEASUREMENTS POLAR PLOTS (1/3 OCTAVE)  
10 Hz  
125Hz  
160Hz  
20 Hz  
250Hz  
315Hz  
400Hz  
500Hz  
0
0
330  
0
-12  
-24  
30  
330  
0
-12  
-24  
30  
300  
60  
300  
60  
-36  
-48  
-36  
-48  
270  
90  
270  
90  
630HHzz  
800Hz
1.0kHz  
1.25kHz
1.6 kHz  
2.0kHz  
2.5 kHz  
0
0
3.15 kHz  
330  
0
30  
330  
0
30  
-12  
-12  
300  
60  
300  
60  
-24  
-24  
-36  
-48  
-36  
-48  
270  
90  
270  
90  
4.0kHz  
5.0kHz  
6.3kHz  
8.0kHz  
1.0kHz  
12.5kHz  
16kHz  
0
0
2.0kHz  
330  
0
30  
330  
0
30  
-12  
-24  
-12  
-24  
300  
60  
300  
60  
-36  
-48  
-36  
-48  
270  
90  
270  
90  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Definition Install DC6i data file // issue 1.06 // 15.01.08  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 7  
Definition Install DC6i  
DIMENSIONAL SKETCHES  
9.84”  
8.45”  
250.0mm  
214.6mm  
334.0mm  
13.15”  
SUPPLIED WALL MOUNTING PLATE  
12  
0.0mm  
150.0mm  
4.72”  
5.91”  
90.0mm  
150.0mm  
3.54”  
5.91”  
Ø5.0mm  
Ø0.20”  
Fixing hole dimensions  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Definition Install DC6i data file // issue 1.06 // 15.01.08  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 8  
Definition Install DC6i  
Architectural specifications  
The loudspeaker shall consist of a 150mm (6.00”) full range, point source Dual Concentric™ transducer. The low and high frequency elements shall be  
combined by an internal passive crossover network operating at 1.6kHz with dynamic HF protection.  
Performance of the loudspeaker, without any electronic control, shall meet or exceed the following criteria: Frequency range measured at 1 metre on axis  
with swept sine wave shall be 70Hz to 45kHz. Sensitivity shall be at least 90dB (anechoic) for 2.83 Volts @ 1 metre and shall be capable of producing a  
peak output level of 116dB (anechoic) on axis at 1 metre. The dispersion of the loudspeaker shall be 90 degrees conical (-6dB). The system shall have a  
nominal impedance of 8 Ohms and maximum power handling shall be 200 Watts (programme).  
The enclosure shall be an optimally tuned 11.9 litre vented cabinet of MDF construction. Connectors shall be 2 x 4mm binding posts. The enclosure shall be  
fitted with 8 x integral M10 bracket inserts and 4 x keyhole fixings for portrait or landscape mounting using supplied wall plate.  
The enclosure shall not exceed the following dimensions: 334 x 250 x 214mm (13.15 x 9.84 x 8.45”) (H x W x D).  
The loudspeaker shall be the Tannoy… Definition Install DC6i.  
Tannoy United Kingdom  
Tannoy North America  
Tannoy Deutschland  
Tannoy France  
T: 00 44 (0) 1236 420199  
T: 00 1 (519) 745 1158  
T: 00 49 (180) 1111 881  
T: 00 33 (0)1 7036 7473  
Definition Install DC6i data file // issue 1.06 // 15.01.08  
Tannoy adopts a policy of continuous improvement and product specification is subject to change  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Home Theater System EM 3731 II User Manual
Sharp Flat Panel Television C 32LE360EN User Manual
Sharp Portable CD Player DK KP85PH User Manual
Sherwood Stereo Receiver R 872 User Manual
Soleus Air Dehumidifier SG DEH 70EIP 6 User Manual
Sony Home Theater System DAV HDX277WC User Manual
Stanton Musical Instrument RM 50f User Manual
Sterling Plumbing Indoor Furnishings 26290 User Manual
Sterling Plumbing Outdoor Shower 1505D 42 User Manual
Sunrise Medical Mobility Aid J Gel User Manual