MANUAL
User Manual for
Sunways Solar Inverter NT 10000
200
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of contents
1.0 General Information
1.1 Safety Instructions
91
92
General Safety Instructions
Opening the Device
1.2 Sunways Solar Inverter
NT 10000
93
94
Scope of Delivery
R
in the PV System
GB
96
98
Structure of NT 10000
Protection Concept
2.0 Installation Instructions
2.1 Safety Instructions
S
101
101
102
Electrical Safety
Mechanical Safety
Cleaning Instructions
2.2 Basic Settings
2.3 Installation
103
104
Setting the Fixed Voltage Level
Country Settings
107
108
108
109
112
115
Installation Site Requirements
Mechanical Installation
Electrical Connection and Cable Entry
Grid Connection
Connecting the PV Generator
Communication Interfaces
87
Download from Www.Somanuals.com. All Manuals Search And Download.
118
120
Connecting the Alarm Relay
Connecting the Insolation and
Temperature Sensor
2.4 Commissioning the Solar Inverter 122
Starting-Up and Shutting-Down the
Solar Inverter
2.5 Dismantling the Solar Inverter
123
General Information
3.0 Operating Instructions
3.1 Operating the Display
125
125
125
126
Menu Guide
Navigating with the Arrow Keys
Setting Values
Menu Navigation Diagram
3.2 Configuration of the Solar Inverter 128
Setting the RS485 address
Setting the Date / Time
Setting the Display Language
Setting the LCD Contrast
Setting the Total Yield
128
128
128
128
3.3 3.3 Internal Data Memory
129
130
131
General Information
General Information
General Information
3.4 Sunways Monitor 2.0 Software
3.5 Sunways Portal and Sunways
Communicator
88
Download from Www.Somanuals.com. All Manuals Search And Download.
3.6 Communication Link
131
132
132
133
Modem Link
Interface Cables
Interface Transformer
Linking and Interconnecting Possibilities
3.7 Error Display
139
144
3.8 Error Diagnosis
4.0 Appendix
4.2 Tyco Solarlok Connectors
154
156
Safety Instruction and Installation
Designation and Description
4.2 List of Special Terms and
Abbreviations
4.3 Technical Data NT 10000
158
Solar Inverter NT 10000
4.4 Conformity and Safety
Declarations
160
161
EU Low Voltage Directive 73/23/EEC
EMC Directive 89/336/EEC, Including Changes
91/263/EEC
162
163
165
Safety Clearance / Certificate of Compliance
(VDEW 4th edition 2001)
4.5 Terms and Conditions of
Guarantee
Duration of Guarantee, Conditions,
Exclusion of Liability
4.6 General Exclusion of Liability
Rights, Registered Trademarks
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Thank you for having chosen a Sunways
Solar Inverter NT 10000! You have acquired
a high-quality product with unique features
and a top efficiency level. This Solar Inverter
is designed in accordance with the proven
1.0 General information
®
HERIC topology and therefore guarantees
you a maximum energy yield.
The Solar Inverter is equipped with three
independent energy units which transform
the energy of three separately connected
PV generators into grid-compatible AC
power and inject it in three phases. Thanks
to the MPP multitracking process, PV gene-
rators with various ratings can be connected
to the same Solar Inverter with the
NT 10000.
In this user manual, you will find explana-
tions on how to use the Sunways Solar
Inverter NT 10000. It includes information
on installation, commissioning, the functio-
ning method, and system monitoring.
90
Download from Www.Somanuals.com. All Manuals Search And Download.
1.1 Safety Instructions
General Safety Instructions
The user manual contains safety instruc-
tions. They are marked by a triangle with
an exclamation mark.
All safety instructions contained in this
section as well as in the entire user manu-
al must be observed to ensure the safety
of the user. The described product may
not be operated if any mechanical or elec-
trical component is defect.
!
ꢀ
Prior to commissioning the PV system, we
strongly recommend reading and observing
the manual and the instructions carefully!
Non-compliance may lead to serious con-
sequences such as damage to the device,
damage to other assets, personal injury, or
fatal accidents.
GB
The Solar Inverter may only be installed
by a trained and qualified electrician.
It must be approved by the power supply
company in charge. In the chapter
headings, the due steps are additionally
marked by the adjacent symbol.
91
Download from Www.Somanuals.com. All Manuals Search And Download.
Opening the Device
!
Prior to opening the housing, always
disconnect the device from the grid and
the PV generator.
ꢀ
After having been disconnected from the
PV generator, there is still lethal voltage
inside the device and at the PV generator
hubs for approximately five minutes. It
takes that long for the energy-storing
capacitors to fully discharge.
After having disconnected the device
from the grid and the PV generator, wait
at least five minutes before opening the
device.
92
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 Sunways Solar Inverter NT 10000
Scope of Delivery
Checking the Consignment
Prior to shipment, our products are chec-
ked to make sure they are in a perfect con-
dition. They are carefully packaged in recy-
clable materials. Nevertheless, damage may
occur during transportation which is nor-
mally the fault of the forwarding company.
· Sunways Solar Inverter NT 10000
· assembly frame
· user manual, setup, guarantee card,
CD ROM with software
· 3 pairs of Tyco Solarlok connectors
Please check the delivered Solar Inverter
carefully!
GB
Should you notice any damage to the
packaging or to the Solar Inverter, please
notify the forwarding company immedi-
ately. If required, your specialist dealer will
be glad to support you. If a damage report
is needed, it must be filed with the forwar-
ding company no later than seven days
after receipt of the consignment.
93
Download from Www.Somanuals.com. All Manuals Search And Download.
Integrating the Solar Inverter
in the PV System
· The warmer the module gets, the smal-
ler the output of the cells will be.
Therefore, make sure your PV generator
has sufficient back ventilation when you
install it.
Rating of the PV Generator
The technical data of the selected PV
generator must be compatible with the
specification of the Solar Inverter (see
Technical Data). An incompatible rating
may reduce the yield or destroy the
device. The rating program Sunways NT
Sundim can help you select the correct PV
generator rating. You will find Sunways
NT Sundim on the enclosed CD ROM or
· Check your PV generator for contami-
nation approximately every three years.
Contamination mostly occurs on the
lower edge of the module; it forms a
veil that is not even washed off by
heavy rain. A loss of yield can be pre-
vented by cleaning the modules with a
wet cloth or a brush.
Prior to planning your system, please take
the following considerations into account:
· Make sure none of the modules or solar
cells of your system are in the shade.
That may lead to a significant loss of
yield.
· Mind the orientation of the modules.
In Central Europe, you will gain a maxi-
mum yield if the module has a horizon-
tal angle of 30° and the PV generator
field points directly towards the south.
· The NT 10000 has three internal energy
units that are supplied by three inde-
pendent PV generators. The NT 10000 is
based on the «MPP multitracking» prin-
ciple; i. e. each inlet has its own MPP
controller.
94
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Components of a PV System
Depending on the recommendations of
your PV planner, your PV system is made
up of the following components:
Standard components of the PV system
(1) PV generator switch
(2) Insolation sensor with
integrated temperature
probe
(3) Grid fuse
(4) Power meter
PV
PV
PV
(1)
(1)
(1)
(3)
(4)
PC
GRID
(2)
The PV generator switch is designed as a
DC switch-disconnector and is made for
disconnecting the PV generator from the
Solar Inverter.
Grid connection:
The NT 10000 is connected to the grid in
three phases. Each phase is internally con-
trolled and monitored independently of
the others.
Rating: at least 900 V, ≥16 A
Since the NT 10000 is supplied by three
independent PV generators, the DC main
switches must also be independently of
each other. It can be designed as a packet-
type switch, for example.
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Structure of NT 10000
The Solar Inverter NT 10000 is made up of
three energy units that are controlled
independently of each other. Each energy
unit has its own DC inlet.
DC Inlet
Energy Unit
Control Circuit Board
Control circuit board 1
Control circuit board 2
Control circuit board 3
AC Grid Connection
Phase L1
DC inlet 1
DC inlet 2
DC inlet 3
Energy unit 1
Energy unit 2
Energy unit 3
Phase L2
Phase L3
The following illustration shows the con-
nection of the DC inlet and the layout of
the energy unit:
96
Download from Www.Somanuals.com. All Manuals Search And Download.
Solar Inverter NT 10000
Energy unit 3
Energy unit 2
Control circuit board 3
Control circuit board 2
Control circuit board 1
Energy unit 1
L1
L2
L3
N
Interface circuit board
PE
+
+
+
Underside of
the device
AC grid
connection
(1) (2) (3)
–
DC inlet
–
–
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Protection Concept
The micro controller continuously and
simultaneously monitors and displays the
following parameters. Numbers 1 to 3
refer to the energy units 1 to 3:
The numbering 1 to 3 refers respectively
to the performance unit 1 to 3:
Error
No.021
022
Description
Error No.
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
Description
DC overvoltage 1
Insulation fault 2
Insulation fault 3
DC injection 1
DC overvoltage 2
DC overvoltage 3
023
Frequency fault 1
024
DC injection 2
Frequency fault 2
025
DC injection 3
Frequency fault 3
026
Isolated operation
Grid overvoltage 3-phase
Surge fault 1
Overheating of heat sink 1
Overheating of heat sink 2
Overheating of heat sink 3
Grid undervoltage 1-phase 1
Grid undervoltage 1-phase 2
Grid undervoltage 1-phase 3
Grid overvoltage 1-phase 1
Grid overvoltage 1-phase 2
Grid overvoltage 1-phase 3
Grid undervoltage 3-phase
AFI fault 1
027
028
029
Surge fault 2
030
Surge fault 3
031
Grid voltage 10 minutes mean value
> 10 percent U
1
nominal
032
033
Grid voltage 10 minutes mean value
> 10 percent U
2
nominal
Grid voltage 10 minutes mean value
> 10 percent U
3
nominal
034
035
036
038
Control circuit board 1 fault
Control circuit board 2 fault
Control circuit board 3 fault
Back-up battery empty
AFI fault 2
AFI fault 3
Insulation fault 1
98
Download from Www.Somanuals.com. All Manuals Search And Download.
In case of an error, the current injection
is immediately stopped, and the grid relay
is triggered which disconnects the Solar
Inverter from the grid.
In addition, there are the following pro-
tection devices on the grid side and on
the PV generator side:
· Varistors on the grid side
GB
They protect the power semiconductors
in case of high-power, temporary voltage
peaks in the grid, and they discharge the
throttle in case of disconnection from
the grid.
· Varistors on the PV generator side
Varistors offer protection from atmos-
pheric overvoltage (e. g. caused by
remote lightning strikes).
99
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 Installation Instructions
100
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1 Safety Instructions
Electrical Safety
Prior to opening the housing, disconnect
the Solar Inverter from the electricity of
the grid and the PV generator.
!
ꢀ
After disconnection from the PV generator
and the grid, there is still lethal voltage
inside the Solar Inverter and at the
ꢀ
PV generator hubs for approximately five
minutes. It takes that long for the energy-
storing capacitors to fully discharge.
GB
After having disconnected the Solar Inver-
ter from the grid and the PV generator,
wait at least five minutes before opening
the Solar Inverter.
Mechanical Safety
During assembly, make sure the cables
or connecting lines attached to the Solar
Inverter are installed safely and suitable
mechanical cable retaining devices (e. g.
cable channels) are used.
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning Instructions
!
Prior to cleaning your PV modules, always
disconnect the PV system from the power
grid by opening the grid disconnecting
device (main fuse), and open the DC circuit
breaker on the PV generator to prevent
the risk of an electric shock.
ꢀ
Use a dry, soft cloth to clean your PV
modules. Never use caustic, solvent-based,
or scouring cleaning agents or polish.
Please observe the instructions of the
PV module manufacturer.
102
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Basic Settings
«420 V» position
«540 V» position
Setting the Fixed Voltage Level
Your Sunways Solar Inverter is equipped
with a precise MPP control. If less than
200 watt are injected, the control of the
energy unit concerned operates at a fixed
voltage level. That prevents unnecessary
MPP searching. To minimise adjustment
losses during fixed voltage operation, the
fixed voltage level of each energy unit of
the Solar Inverter can be set separately.
The optimum fixed voltage level depends
on your PV generator model.
GB
Illustr.: Slide switch «S100» for setting the
fixed voltage level
Fixed voltage
level
No-load voltage
PV generator at 25 °C
420 V
540 V
≤ 630 V
> 630 V
The fixed voltage can be set with the slide
switch «S100» on the control circuit board.
Ex works, the switch is set to «420V».
To set a fixed voltage of 540 V, slide the
switch to the «540V» position.
103
Download from Www.Somanuals.com. All Manuals Search And Download.
Country Settings
Please note that it takes different configu-
rations to operate Sunways Solar Inverters
in different countries. The setting can be
adjusted accordingly with the DIP switch
«S300» below the display circuit board.
Illustr.: DIP switch «S300» for changing the
country setting
Switch position
Change
Country
Germany
Spain
· Opening time after power failure: 3
· Grid monitoring 1-phase
104
Download from Www.Somanuals.com. All Manuals Search And Download.
To change the country setting, the housing
cover must be removed. The DIP switch
must be re-positioned to the respective
country setting on all three control circuit
boards.
When delivered, the Solar Inverters are
pre-set to the intended destination coun-
try. The pre-set country is indicated by
the first two digits of the serial number:
GB
Germany
Spain
00.....
02.....
105
Download from Www.Somanuals.com. All Manuals Search And Download.
The Solar Inverter may only be installed by
a trained and qualified electrician.
2.3 Installation
Special tools are needed for installation.
Please read this chapter very carefully.
!
ꢀ
Ceiling
Warm
air
Wall
min. 300 mm
min. 300 mm
Cool air
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Site Requirements
If the Solar Inverter is installed in a switch
cabinet, make sure the heat is removed to
a sufficient degree.
· Mechanical Load-Bearing Capacity
During assembly, please keep in mind that
the Solar Inverter weighs 30 kg. The
assembly foundation must be solid and
capable of bearing the weight in the long
run.
The ambient temperature may not drop
below -25° C or rise above +40° C.
To protect the Solar Inverter from unneces-
sary external heat sources, do not expose
the Solar Inverter to direct sunlight.
· Thermal Interaction
GB
The assembly foundation must be made
of flame-retardant material (unsuitable:
wooden or plastic foundation; suitable:
concrete and masonry), because the frame
of the Solar Inverter can reach up to 70° C.
· Protection from Moisture and Foreign
Objects
Thanks to the high protection level IP 54,
the Solar Inverter can be installed indoors as
well as in a sheltered outdoor area, but it
may not be directly exposed to rain.
Maintain a minimum distance of 300 mm
to other devices, cabinets, ceilings, cable
channels, etc. above, below, and next to
the housing.
Make sure the dust filter on the lower left
side is not clogged by contamination.
That would impair the intake of cooling air.
Depending on the surroundings, the filter
should be cleaned at regular intervals.
The Solar Inverter must be installed in an
upright position to ensure unobstructed
convection.
Do not install several Solar Inverters on
top of each other, as they might heat
each other up.
107
Download from Www.Somanuals.com. All Manuals Search And Download.
Mechanical Installation
Electrical Connection and Cable Entry
!
!
ꢀ ꢀ
For assembly, please observe the instruc-
As soon as the Solar Inverter is fixed to the
tions in the «Setup» leaflet!
assembly frame, it can be electrically con-
nected. The device may only be opened
by a qualified electrician. For this purpose,
loosen the four lateral hexagon socket
screws by one rotation. The cover can now
be moved up to the upper rabbet. Fix the
cover in position by simply inserting the
hexagon key on the lower right side. The
wiring space is now accessible.
108
Download from Www.Somanuals.com. All Manuals Search And Download.
Grid Connection
As an input-to-grid line protection ele-
ment, we recommend using a 3 x 25 A
automatic circuit breaker for the NT
10000. No consumers may be connected
to the supply line from the Solar Inverter
to the automatic circuit breaker. The Solar
Inverter injects in three phases via termi-
nals L1, L2, and L3. Please mind the pin
assignment. A wrong assignment may
destroy the device.
The Solar Inverter must be connected to
the grid with five-cores (L1, L2, L3, N, PE).
We recommend a cable cross-section of
2
5 x 4 mm .
The Solar Inverter is connected to the
supply grid via its internal printed-circuit
board terminals.
GB
Alarm relais, RS485 (in and out),
DC1 DC2 DC3
AC wiring loom
L1, L2, L3, N, PE
irradiation sensor with integrated
temperature measurement
DC+
DC–
USB
RS232
Illustr.: Entry openings on the underside of the device
109
Download from Www.Somanuals.com. All Manuals Search And Download.
Three-phase grid connection
PE N L3 L2 L1
25 A
Always use sufficiently dimensioned cable
cross-sections to prevent a significant incre-
ase of the grid impedance between the
service distribution system and the Solar
Inverter. The capacity of the AC terminals is
Inverters may repeatedly switch on and off.
Carry out the following steps carefully:
· Prior to inserting the power cable into
the device, make sure it is de-energised.
2
2
0.5 mm to 6 mm for rigid cables, and 0.5
2
2
mm to 10 mm for flexible cables. If the
grid impedance is high, i. e. due to relati-
vely long or thin cables, the voltage at the
grid terminal is increased during injection.
If the terminal voltage exceeds the admissi-
ble value, the Solar Inverter is disconnected
from the grid. If the power grid is weak
and the PV output is high, individual Solar
110
Download from Www.Somanuals.com. All Manuals Search And Download.
· Insert the five-core AC cable (outer
diameter 9–17 mm) into the M32 cable
gland.
· Connect lines L1, L2, L3, N, and PE to
the slated printed circuit board terminal
with a slotted screwdriver.
GB
· Pull the M32 cable gland tight, so the
cable cannot exert mechanical force on
the printed circuit board terminal.
111
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Accessible and conductive parts of the
PV generator (e. g. metal frame, support
structure, etc.) must be earthed (connec-
tion to PE).
Connecting the PV Generator
!
ꢀ
5. Make sure the PV generator is earth-
fault free.
· Preparation
Please note that the NT 10000 has three
independent DC inlets. The PV generators
may have different ratings, but they must
be compatible with the specifications of
the Solar Inverter.
6. Connect the Solar Inverter to the power
line.
1. Install the DC cables in accordance with
the system ratings prescribed by your PV
planner. Measure the no-load voltage
and the short-circuit current of each PV
phase to make sure they work perfectly.
2. Read the type plate of the Solar Inverter
to make sure it is licensed for the maxi-
mum PV generator voltage.
3. To avoid dangerous touch voltage
during the assembly of PV systems, the
positive and negative conductors must
be kept away from the earth potential
(PE) electrically.
112
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Information
· Connection
The PV generator is connected by means of
the externally accessible, touch-safe Tyco
Solarlok connectors included in the con-
signment. The Tyco Solarlok connectors are
!
ꢀ
2
designed for a cable cross-section of 4 mm
· The DC voltage can reach up to 850 V.
The device may only be opened by a
qualified electrician!
and have to be crimped. For further infor-
mation, please read chapter 4.2 «Tyco
Solarlok Connectors».
GB
· As soon as the PV generator has been
connected to the Solar Inverter by means
of the DC connectors and the PV genera-
tor has been switched on, the PV genera-
tor voltage is applied internally!
Please note:
All PV generator inlets are positioned in
pairs. Inlet 1 is left, inlet 2 is in the middle,
and inlet 3 is right. The upper connections
are «POSITIVE», and the lower ones are
«NEGATIVE».
· Please note that the inlet capacitors are
still live, even after the PV generator has
been switched off or the PV generator
connector has been pulled out!
· After the AC and DC sides have been
isolated, the Solar Inverter remains live
for up to approximately five minutes!
· Therefore, wait at least five minutes for
the internal voltage to discharge. Prior to
working on the Solar Inverter, always
Illustr.: PV generator connection via Tyco
Solarlok connectors
113
Download from Www.Somanuals.com. All Manuals Search And Download.
check the residual DC voltage with a volt-
meter. Then you may work on the termi-
nals. See chapter 2.1.
· Always disconnect the PV generator side
first by opening the PV generator switch;
then interrupt the grid connection by iso-
lating (switching off) the corresponding
grid fuse!
· Never disconnect the PV generator by
pulling out the Tyco Solarlok connectors
under load. Otherwise a powerful electric
arc might damage the connectors. The
damaged connectors then have to be
replaced!
· If your PV system does not have a PV
generator switch, interrupt the grid con-
nection by isolating (switching off) the
corresponding grid fuse first. A fault will
then be recorded in the fault memory
of the Solar Inverter, however.
114
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication Interfaces
!
ꢀ
The communication interfaces enable you
to retrieve operating data from the data
memory with an external computer and to
change certain settings. There are several
communication interfaces: USB, RS232,
and RS485.
Illustr.: USB connector (left) and SUB-D9
connector (right) for the RS232 connection
on the underside of the device.
GB
The standard communication interface is
the USB interface which is installed in
every common PC or Notebook. This inter-
face will let you communicate with your
Solar Inverter via an interconnecting USB
cable. As an alternative, you can also use
the RS232 interface. The RS485 interface is
for cross-linking several Solar Inverters.
The USB and RS232 interfaces are connec-
ted on the outside of the housing with a
standard USB connector or a SUB-D9 con-
nector.
Illustr.: Terminal block for the RS485
connection
115
Download from Www.Somanuals.com. All Manuals Search And Download.
· RS485 Wiring
Use a twisted two-wire cable for the RS485
wiring of the Solar Inverter. Connect the
terminals «RS485 +» between the Solar
Inverters with one core and the terminals
«RS485 -» with the other.
Solar Inverters NT 10000 can be cross-lin-
ked via RS485. When doing so, please keep
in mind that the Solar Inverters must be
connected in series. Cross-linking them
point-to-point is not admissible. Interface
RS485 is connected via the printed circuit
board terminals and the corresponding
M12 cable glands inside the housing. Prior
to wiring the RS485, move the cover of the
Solar Inverter up, and fix it in position by
tightening a lateral screw. See chapter 2.1
«Safety Instructions».
If you use a shielded twisted two-wire
cable, you can earth the shield. That will
improve the communication reliability.
With the last Solar Inverter, the jumper
«RS485 MATCH» must be closed. With all
other Solar Inverters, it has to be in the
open position (see chapter 3.6 «Com-
munication Link»).
The required cable terminal block («X6»)
with the connections «RS485 +», «RS485 -»,
and «RS485 GND» is in the lower section of
the circuit board (see illustr. page 115).
Caution: There are two each of all termi-
nals, so the ingoing and outgoing lines can
be connected separately.
· Connecting a cable to the spring-loaded
terminal
· Use a small screwdriver. Press the orange
terminal. The terminal will open.
· Insert the (at least 11 mm bare) cable into
the respective terminal hole.
· Release the pressure from the screw-
driver. The cable is now attached to the
connection.
· Make sure the cable is connected tightly.
116
Download from Www.Somanuals.com. All Manuals Search And Download.
Inverter 2
Inverter 3
Inverter 1
Jumper
SPARE
RS485MATCH
SPARE
RS485MATCH
SPARE
RS485MATCH
RS485
connection
Interface
transformer
IT
USB/RS232
· Release the pressure from the screw-
driver. The cable is now attached to the
connection.
· Make sure the cable is connected tightly.
117
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Alarm Relay
The required terminal block with the
connections «S-» and «S+» is on the lower
right side of the circuit board («X5»).
Allocate the terminals as shown:
All Sunways Solar Inverters are equipped
with a potential-free alarm relay. The relay
is designed as a make-contact element
and is always triggered when the device
reports an error. That ensures that any
faults in the PV system are reported
quickly and reliably on site. With PV
systems with several Solar Inverters, the
individual relays can be paralleled and
connected via a joint indicator light.
· Important Information:
!
ꢀ
The alarm relay is rated for 230 V / 2 A.
Any higher power/voltage may destroy the
relay. The connected indicator module
must be fused separately!
The alarm relay cannot be triggered if
there is a power failure on L1, because
that is the supply phase for the Solar
Inverter.
· Connecting a cable to the spring-loaded
terminal
The alarm relay cannot be triggered if
there is a grid failure on L1 since this is
the supply phase for the solar inverter.
· Use a small screwdriver. Press the orange
terminal. The terminal will open.
· Insert the (at least 11 mm bare) cable
into the respective terminal hole.
· Release the pressure from the screwdri-
ver. The cable is now attached to the
connection.
· Connection
Move the cover of the Solar Inverter
up, and fix it in position by tightening a
lateral screw. See chapter 2.1 «Safety
Instructions».
· Make sure the cable is connected tightly.
118
Download from Www.Somanuals.com. All Manuals Search And Download.
The terminals are designed for a cable
2
2
cross-section of 0.2 mm to 1.5 m .
When selecting the dimensions of the
cross-section, please keep the power
consumption of the connected indicator
module in mind!
Illustr.: Alarm relay connection
GB
Alarm relay terminal allocation
Paralleled alarm relays of several Solar
Inverters
INVERTER
(1)
INVERTER
(2)
INVERTER
(n)
S –
S–
S+
S+
INDICATOR LIGHT
L1 N
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Insolation and
Temperature Sensor
The optional insolation sensor with the
temperature probe is connected to the
cable terminal block «X4» in the lower
section of the circuit board.
The optional insolation sensor (type
Si-01TC-T by Ing.-Büro Mencke & Tegt-
meyer) with its integrated PT-100 tempera-
ture probe for measuring the temperature
lets you record the insolation data and the
corresponding module temperature and
store them in the internal data memory
as a 15-minute average value.
This additional measuring unit helps you
analyse the performance of the system.
Based on the values, any faults in the PV
generator, e. g. shaded or defect solar
cells, can be detected.
Illustr.: Connection insolation sensor
Prior to connecting an insolation sensor,
move the cover of the Solar Inverter up,
and fix it in position by tightening a late-
ral screw. Please note that the inlets and
outlets are not short-circuit-proof. Please
observe chapter 2.1 «Safety Instructions».
120
Download from Www.Somanuals.com. All Manuals Search And Download.
· Allocation of the cable terminal block:
Sensor pin name
Pin allocation
Solar inverter pin name
sensor connector
Plus signal temperature
Plus signal insolation intensity
Plus connection supply +5 V
Earth reference
Pin 1
Pin 2
Pin 3
Pin 4
S-Temp
P-Solar
V+
V-
· Use a small screwdriver. Press the
orange terminal. The terminal will open.
· Insert the (at least 11 mm bare) cable
into the respective terminal hole.
· Release the pressure from the screw-
driver. The cable is now attached to
the connection.
· Make sure the cable is connected tightly.
121
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4 Commissioning the Solar Inverter
Starting-Up and Shutting-Down the
Solar Inverter
Prior to starting up the Solar Inverter,
move the housing cover downwards by
releasing the lateral fixation on the right
lower side of the housing and pulling the
four lateral hexagon socket screws tight.
As soon as the Solar Inverter has been
mechanically installed and connected to
the power lines, it can be commissioned as
follows. Depending on whether or not you
are using DC main switches, the start-up
and shut-down sequence for the DC and
AC side differs.
Do not deposit any objects (e. g. this
manual) on the housing of the Solar
Inverter. The ventilation behind the Solar
Inverter must not be obstructed.
Note: The Solar Inverter is supplied from
the grid. If the PV output is high enough,
the Solar Inverter will switch on autom
atically. For that purpose, on and off thres-
hold values have been determined.
If the device is installed outdoors, please
double-check that the cable glands, the
housing cover, and the protection cap of
the SUB-D9 connector (provided this ter-
minal is not allocated) are tight.
Start-up (with DC main switch)
1. Switch the grid connection on with the
external automatic circuit breaker.
2. Switch the PV generator voltage on
by closing the DC main switch. If the
PV input voltage is sufficient, the Solar
Inverter will start and inject solar
energy into the electrical grid. The
injection is indicated by the power
pointer on the display.
122
Download from Www.Somanuals.com. All Manuals Search And Download.
Start-up (without DC main switch)
1. Connect the Tyco Solarlok connectors
to your Solar Inverter.
!
ꢀ
2. Start-up the AC side.
Never disconnect the PV generator by
pulling out the Tyco Solarlok connectors
under load! Otherwise a powerful electric
arc might damage the connectors.
The damaged connectors then have to
be replaced!
Shut-down (with DC main switch)
1. Disconnect the PV generator side by
opening the DC main switch.
GB
2. Open the grid connection by isolating
(switching off) the corresponding grid
fuse.
2.5 Dismantling the Solar Inverter
To dismantle the Solar Inverter, loosen the
hexagon socket screws, and move the
cover up. Make sure the Solar Inverter is
de-energised; then remove the supply
lines. The Solar Inverter may then be lifted
out of the assembly frame.
3. After a waiting time of at least five
minutes, the Solar Inverter is deener
gised.
Shut-down (without DC main switch)
1. Interrupt the grid connection by isola-
ting (switching off) the corresponding
grid fuse. A fault will then be recorded
in the fault memory of the Solar
Inverter.
2. Pull the Tyco Solarlok connector out of
your Solar Inverter.
123
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 Operating Instructions
1824
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1 Operating the Display
· Menu Guide
Activate the main menu by pressing any
random key. In the top menu level, there
are four items to choose from:
· display current values
A dot matrix LCD display with 2 x 16 cha-
racters is integrated in the housing of the
Solar Inverter. The language of the dis-
played messages can be selected (German,
English, Spanish, Italian, or French). The
four arrow keys to the right of the display
are for navigating the menu structure. The
background lighting of the display is acti-
vated by pressing any random key. It auto-
matically switches off if no input is made
for more than one minute.
· display energy yield
· change settings
· display Solar Inverter specifications
· Navigating with the Arrow Keys
GB
You can use the UP arrow
and DOWN
ꢁ
ꢁ
arrow
level. To select a menu item, press the
RIGHT arrow key . To return to a
higher menu level, press the LEFT arrow
key
keys to scroll within a menu
As a standard, line one of the display
shows the current total output of the Solar
Inverter, and line two shows the partial
output of the three energy units 1 to 3.
This information is always displayed if no
key is pressed for one minute.
.
· Setting Values
To set values, move to the next figure by
pressing the RIGHT arrow key. To change
the current figure, press the UP/DOWN
arrow key. If the cursor is on the last figu-
re, you can confirm the input by pressing
the RIGHT arrow key. To abort the changes
during entry, press the LEFT arrow key.
125
Download from Www.Somanuals.com. All Manuals Search And Download.
If a displayed value can be changed, an
arrow is shown behind it. In this case, press
the RIGHT arrow key to reach the «edit«
mode.
Main menu
Display current
values
The current power and voltage values are
displayed separately for each of the three
energy units.
Display
yield
ꢁ
ꢁ
Change
settings
Solar Inverter
specifications
126
Download from Www.Somanuals.com. All Manuals Search And Download.
Power (kW)
DC current (A)
DC voltage (V)
AC current (A)
AC voltage (V)
ꢁ
ꢁ
ꢁ
Temp. module (°C)
2
Insolation (W/m )
Date / Time
Error display
Today’s yield
Yesterday’s yield
Monthly yield
ꢁ
Annual yield
Total yield
Address RS485
Date / Time
Language
Change
ꢁ
ꢁ
ꢁ
LCD contrast
Total yield
Total
ꢁ
Works menu
Energy unit 1
ꢁ
Energy unit 2
Energy unit 3
Change
Serial number
Firmware version
ꢁ
Date of commissioning
127
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 Configuring the Solar Inverter
Setting the Date/Time
To set the time or date, select the menu
item «change settings» / «date/time», and
move to the «edit» mode by pressing the
RIGHT arrow key.
You can enter the following settings in
your Solar Inverter:
· set RS485 address
· set date / time
Setting the Display Language
· set display language
· set LCD contrast
· set total yield
To set the display language, select the
menu item «change settings» / «lan-
guage». Here, you can choose from the
languages German, English, Spanish,
French, and Italian by pressing the
UP/DOWN arrow key. Confirm your input
by pressing the RIGHT arrow key.
Please note that the configuration can only
be changed when the Solar Inverter is ope-
rating. Alternatively, you can change these
settings by using the enclosed software
Sunways Monitor.
Setting the LCD Contrastt
If you wish to change the LCD contrast to
improve the clarity of the display, select
the menu item «change settings» / «LCD
contrast». Press the RIGHT arrow key to
activate the «edit» mode; then select the
desired contrast by pressing the UP/DOWN
arrow key. To confirm your input, press
the RIGHT arrow key.
Setting the RS485 Address
To use the communication via the RS485
bus, the Solar Inverters must have consecu-
tive RS485 addresses. That means, if you
link three Solar Inverters together, their
addresses must be 1, 2, 3. When delivered,
address 1 is preset. To change the address,
select the menu item «settings» / «RS485
address», and press the RIGHT arrow key to
call up the «edit» mode. There, you can
enter an address from 1 to 99.
Setting the Total Yield
If your Solar Inverter needs to be replaced,
you can take over the total yield from the
128
Download from Www.Somanuals.com. All Manuals Search And Download.
former Solar Inverter to your new one.
You can either take over the total yield of
the device, or the individual yield of each
energy unit. If you set the total yield of the
device, it will automatically be split among
the energy units 1 to 3 in equal shares.
If you change the yield of the individual
energy units separately, they will be added
up to the total yield.
3.3 Internal Data Memory
Your Solar Inverter is equipped with an
internal data memory as a standard fea-
ture. With the enclosed software Sunways
Monitor, you can access these data. These
Solar Inverter data will give you detailed
information on the functioning method
and relevant values of your solar energy
supply at any time. The measured values
are stored in a ring buffer that automati-
cally overwrites the earliest values with
the latest ones. The following measured
values are stored in your Solar Inverter
NT 10000:
GB
To do so, select the menu item «change
settings» / «total yield». Here, you can
select the total yield, energy unit 1, energy
unit 2, or energy unit 3. To start changing
the displayed value, press the RIGHT arrow
key.
15 minutes average values (500 data
records, each with date/time):
· DC current
· DC voltage
· AC current
· AC voltage
· injected power
· insolation (optional)
· module temperature (optional)
129
Download from Www.Somanuals.com. All Manuals Search And Download.
In addition, the following total injected
energy values (electrical output) are
stored:
3.4 Sunways Monitor 2.0 Software
General Information
The visualisation software Sunways Monitor
2.0 is for monitoring the PV system and
configuring the Sunways Solar Inverter with
a PC. You can install it on your PC from the
enclosed CD ROM.
· daily yield (40 days)
· monthly yield (13 months)
· total yield (since commissioning)
The last 100 errors of the Solar Inverter
are stored with their date, time, and error
number.
To download the latest software version
on the Internet. Our system recommenda-
tion is:
Please note that, in the nominal case, all
displayed values have a maximum measu-
ring accuracy of 5 percent. The power
meter of your power supply company is an
absolute reference for the injected energy.
· Intel Pentium with at least 500 MHz
· Microsoft Windows 98 Second Edition,
Windows 2000, Windows XP
· Microsoft .NET-Framework 1.1
· 200 MB available ROM
· 256 MB RAM
· VGA monitor with at least 1024 x 768
resolution, at least 256 colours
With the Sunways Monitor 2.0 software, all
measured values stored in the Solar Inverter
are retrieved and filed in a data bank. The
software lets you visualise the measured
values in diagrams or in tables.
130
Download from Www.Somanuals.com. All Manuals Search And Download.
You can flexibly manage as many PV
systems as you like with up to 99 Solar
Inverters and different types of con-
nections (modem or direct).
3.6 Communication Link
Every Sunways Solar Inverter NT 10000 is
equipped with the interfaces RS232, RS485,
and USB, by which it can be connected to
your PC. If the PV system and the PC are
far apart, the data can also be retrieved via
a modem link. If linked via the RS485
interface, up to 99 Solar Inverters can be
monitored and read out.
To learn more about the software possi-
bilities, please read the instructions on
the CD ROM.
GB
3.5 Sunways Portal and Sunways
Communicator
Modem Link
For that purpose, a modem (remote
modem) must be connected to the Solar
Inverter. We recommend using the «ACER
surf 56» modem by ACER as a remote
modem. This accessory is available from
your Solar Inverter dealer.
To supervise a solar system with several
Sunways Solar Inverters, we recommend
using the Sunways Communicator. This
device lets you connect your system to
the Sunways portal where you can access
your system data via the Internet.
Moreover, it can warn you of system faults
by email, fax, or SMS.
For further suppliers, please visit our
website ww.sunways.de.
Connect the second modem (local modem)
to the RS232 interface of your PC.
If you would like to find out more infor-
mation about the Sunways Communicator,
look it up on the supplied CD ROM.
To learn more about the Sunways
Communicator, please look up the infor-
mation on the enclosed CD ROM.
131
Download from Www.Somanuals.com. All Manuals Search And Download.
using products made by ICP Germany to
ensure a reliable data transfer
!
ꢀ
To connect the interface transformer to a
COM port (RS232) of your PC, use the
«I-7520» model; to connect it to a USB-port
of your PC, use the «I-7561» model. This
accessory is available from your Solar
Inverter dealer. For further suppliers, plea-
se visit our website ww.sunways.de.
Modem types not recommended by
Sunways are not necessarily guaranteed
to work.
For the remote modem to automatically
respond to an incoming call and open the
line, it has to be initialised with the
Sunways Monitor software prior to instal-
lation. For this, please also observe the
software instructions.
!
ꢀ
Interface Cables
Depending on the type of link, different
types of interface cables are needed. They
are available from your Solar Inverter dea-
ler. For further suppliers, please visit our
website ww.sunways.de.
To set up the RS485 communication bet-
ween the Solar Inverters properly, the
RS485 addresses have to be set consecuti-
vely, starting with address 01 (see chapter
«Setting the RS485 Address»).
Interface Transformer
If you wish to read out the Solar Inverter
data with your PC via the RS485 interface,
you need an interface transformer to
transform the RS485 signals into PC-compa-
tible RS232 signals. We recommend .
132
Download from Www.Somanuals.com. All Manuals Search And Download.
Linking and Interconnecting Possibilities
Depending on the distance to be overcome and the number of Solar Inverters,
there are the following linking possibilities:
Type of Link
Solar System with 1
Solar Inverter
Distance
Solar System with up to 99
Solar Inverters
(cross-linked via RS485)
Sunways
Monitor Direct
Link
Connection of the PC via
USB (max 5 m) or RS232
(max. 25 m) (see 1)
PC not more than
5 - 25 m away
Connection between the PC and
the Solar Inverter via USB with
the RS485 address 01 (max. 5 m)
(see 4)
Sunways
Monitor Local
Link
Link between Solar
PC not more than
500 m away (mi-
nus RS485 cable
length between
Link between Solar Inverter and
PC via RS485 bus, using an inter-
face transformer at the PC
(see 5)
Inverter and PC via RS485
bus, using an interface
transformer at the PC
the Solar Inverters) (see 2)
Sunways
Monitor
Use of a remote modem
PC more than
500 m away
Connection of the remote
modem via an interface trans-
former at the RS485 of the Solar
Inverter with the RS485 address
01, link via modem at the PC
(see 6)
at the Solar Inverter RS232
port; link via modem at
the PC (see 3)
Remote Link
Sunways
Use of an RS485 cable set
(comes with the Sunways
Communicator)
Sunways Commu-
nicator not more
than 25 m away
Use of an RS485 cable set
(comes with the Sunways
Communicator)
Communicator
Direct Link
Download from Www.Somanuals.com. All Manuals Search And Download.
The cables and interface transformers that
should be used are shown in the following
diagrams.
(1) Local link with a maximum distance of 25 m between the Solar Inverter and the PC
SUB-D9 connector
USB
SUB-D9 connector
USB
PC
(Sunways cable type 1, null modem cable female / female
(alternative: Sunways cable type 5, USB-device cable)
(2) Local link with an interface transformer between the Solar Inverter and the PC
Connection bar
Sub-D9 hub
SUB-D9 connector
RS485
PC
IC
(Sunways cable type 2, modem cable female / male)
(twisted 2-wire cable)
Data+
Data–
IT
134
Download from Www.Somanuals.com. All Manuals Search And Download.
(3) Remote link with a modem between the Solar Inverter and the PC
SUB-D9 connector
Sub-D9 hub
Sub-D9 connector SUB-D9 hub
PC
MODEM
MODEM
(Sunways cable type 2
modem cable hub/connector)
(Sunways cable type 2
modem cable hub/connector)
(4) Local link for up to 99 Solar Inverters with a maximum distance of 25 m
between the Solar Inverters and the PC
RS485
SPARE
RS485MATCH
RS485
PC
SPARE
RS485MATCH
USB
(Sunways cable type 5,
RS485
USB
USB plug)
SPARE
RS485MATCH
135
Download from Www.Somanuals.com. All Manuals Search And Download.
(5) Local link for up to 99 Solar Inverters (IT or USB)
Alternatively USB
RS485
SPARE
RS485MATCH
RS485
PC
PC
SPARE
RS485MATCH
USB
SUB-D9
connector
RS485
USB
SUB-D9 hub
SPARE
IT
IT
RS485MATCH
(twisted pair
cable)
(Sunways cable type 2,
(Sunways cable type 5,
USB device cable)
modem cable female / male)
Ad (5): Local Link for up to 99 Solar
interface transformer with the following
allocation: «RS485 +» to «DATA+» and
«RS485 -» to «DATA-».
Inverters
With this interconnection, up to 99 Solar
Inverters can be cross-linked and read out.
That results in a maximum RS485 cable
length of 500 m between the Solar
Inverters and the interface transformer.
The interface transformer transforms the
RS485 signal into RS232. It is linked to the
PC with cable type 2 (standard modem
cable). With the Solar Inverter that is fur-
thest away from the interface transformer,
the jumper RS485 MATCH must be closed.
The RS485 signal is transferred from the
first Solar Inverter in the row into the
136
Download from Www.Somanuals.com. All Manuals Search And Download.
With all other Solar Inverters, it has
to be in the open position.
!
ꢀ
To identify the individual Solar Inverters, a
clear RS485 has to be assigned to each of
them. See chapter «Setting the RS485
Address».
(6) Remote link for up to 99 Solar Inverters with an interface transformer and a modem
RS485
SPARE
RS485MATCH
(twisted pair cable)
RS485
PC
SPARE
RS485MATCH
SUB-D9
connector
(twisted pair cable)
SUB-D9
connector
SUB-D9
hub
SUB-D9
hub
RS485
SPARE
MODEM
IT
MODEM
RS485MATCH
(Sunways cable type 2
modem cable
(Sunways cable type 3
modem cable
(twisted pair cable)
hub/connector)
connector/connector)
Download from Www.Somanuals.com. All Manuals Search And Download.
Ad (6): Remote Link for up to 99 Solar
Inverters
Finding the Jumper «RS485 MATCH»
in the Solar Inverter
If you wish to connect several Solar
Inverters to the remote monitoring system,
the individual Solar Inverters must be cross-
linked via RS485. The RS485 signal of the
first Solar Inverter in the row is transferred
into the interface transformer with the fol-
lowing allocation: «RS485 +» to «DATA+»
and «RS485 -» to «DATA-». Connect the
remote modem to the interface transfor-
mer. With the last Solar Inverter, the jum-
per «RS485 MATCH» must be closed. With
all other Solar Inverters, it has to be in the
open position.
Please make sure the jumper «RS485
MATCH» is in the right position, considering
the communication interconnection you
have chosen. This jumper is on the under-
side of the interface circuit board.
Illustr.: Position of the jumper «RS485
MATCH»
!
ꢀ
To identify the individual Solar Inverters,
a clear RS485 has to be assigned to each of
them. See chapter «Setting the RS485
Address».
138
Download from Www.Somanuals.com. All Manuals Search And Download.
3.7 Error Display
Errors 001 to 003
Your Solar Inverter works fully automatically. · DC overvoltage
Should external or internal factors neverthe- A maximum PV generator no-load voltage
less lead to an error, an error number will be of 850 V is admissible. All components of
flagged on the display. Below, you will find
a description of the error for each error
number. If three consecutive error numbers
are listed in the description, each of them
the DC inlet have a sufficient safety factor. If
this limit is exceeded, the Solar Inverter will
stop the injection, and «error 001» will be
flagged, for example. That means an over-
refers to an energy unit of the Solar Inverter. voltage of the PV generator on inlet 1 or on
E. g. for the description of errors 004 to 006, the lower energy unit.
this means:
GB
· Error 004 refers to:
Errors 004 to 006
DC inlet 1 (left DC connection)
energy unit 1 (lower control circuit board)
grid phase L1
· Frequency fault
The Solar Inverter continuously monitors
the applied grid frequency. Should it be
outside the range specified in E DIN VDE
0126-1-1, the Solar Inverter will stop the
· Error 005 refers to:
DC inlet 2 (middle DC connection)
energy unit 2 (middle control circuit board) injection, and «error 004» will be flagged,
grid phase L2
for example. That means a grid frequency
error on grid phase L1 or on the lower
energy unit.
· Error 006 refers to:
DC inlet 3 (right DC connection)
energy unit 3 (upper control circuit board)
grid phase L3
139
Download from Www.Somanuals.com. All Manuals Search And Download.
Errors 007 to 009
Errors 013 to 015
· Overheating
· Grid overvoltage 1-phase
Your Solar Inverter is designed for an
ambient temperature of up to +40° C.
If the maximum temperature of the heat
sink is exceeded, the injection will stop.
When the heat sink temperature has
dropped, the Solar Inverter will automa-
tically restart. If the upper heat sink over-
heats, for example, «error 009» will be
flagged.
Your Solar Inverter continuously monitors
the voltage level of the injection phase.
If it rises above the maximum admissible
limit value, the Solar Inverter will stop the
injection and only restart when the voltage
value drops below the maximum admissi-
ble limit value. If there is a grid overvolta-
ge on phase L2, for example, «error 014»
will be flagged.
Error 016
Errors 010 to 012
· Grid undervoltage 3-phase
· Grid undervoltage 1-phase
Your Solar Inverter is equipped with an
intrinsically safe 3-phase grid monitoring
system that complies with E DIN VDE
0126-1-1. The voltage level of phases L1,
L2, and L3 is continuously monitored.
If it drops below the minimum admissible
limit value, the Solar Inverter will stop the
injection and only restart when the voltage
value rises above the minimum admissible
limit value.
Your Solar Inverter continuously monitors
the voltage level of the injection phase.
If it drops below the minimum admissible
limit value, the Solar Inverter will stop the
injection and only restart when the voltage
value rises above the minimum admissible
limit value. If the voltage of L1 drops
below 160 V, the Solar Inverter can no
longer be supplied, and the display will
switch off. If there is a grid undervoltage
on phase L3, for example, «error 012» will
be flagged.
140
Download from Www.Somanuals.com. All Manuals Search And Download.
Errors 017 to 019
Errors 023 to 025
· AFI fault current
· DC injection
The error «AFI fault current» occurs if fault
current has penetrated the PV system and
the Solar Inverter has subsequently discon-
nected from the grid. The earth fault is
monitored on the AC and on the DC side
(universal current sensitive FI). If this error
message occurs, the entire PV system must
be checked for insulation faults. The func-
tioning method complies with E DIN VDE
0126-1-1. In case of fault current at inlet 1
of the PV generator, for example, «error
017» will be flagged.
Your Solar Inverter continuously monitors
the quality of the injected electricity. If an
increased share of DC current is detected in
the injected electricity, the Solar Inverter
will stop the injection The Solar Inverter
will only try to continue the injection after
the system has been shut down and restar-
ted manually, or automatically the next
day.
GB
Error 026
· Isolated operation
Errors 020 to 022
Your Solar Inverter is equipped with a
high-quality redundant grid monitoring
system that complies with E DIN VDE
0126-1-1 and continuously monitors the
grid. If one of the monitoring phases fails,
or if the phase relation changes between
the individual conductors, the Solar
Inverter will stop the injection and only
restart when the error has been elimina-
ted, i. e. when the AC grid works properly
again.
· Insulation faults
Prior to start-up, your Solar Inverter always
checks the PV system for an earth fault or
an insulation fault. Should such a fault be
detected, the injection will not start. The
functioning method complies with E DIN
VDE 0126-1-1. In case of an insulation fault
at inlet 2 of the PV generator, for example,
«error 021» will be flagged.
141
Download from Www.Somanuals.com. All Manuals Search And Download.
Error 027
Errors 031 to 033
· Grid overvoltage 3-phase
· Grid overvoltage > 10 percent
Your Solar Inverter is equipped with an
intrinsically safe 3-phase grid monitoring
system that complies with E DIN VDE 0126-
1-1. The voltage level of phases L1, L2, and
L3 is continuously monitored. If it rises
above the maximum admissible limit value,
the Solar Inverter will stop the injection
and only restart when the voltage value
drops below the maximum admissible
limit value.
If the voltage of the injecting phase has
exceeded 253 V for more than ten minutes,
the Solar Inverter will stop the injection
and only try to restart when the grid
voltage is within the admissible range
again. The functioning method complies
with E DIN VDE 0126-1-1. If the applied
grid voltage at phase L2 is higher than
253 V for more than 10 minutes, for
example, «error 032» will be flagged.
Errors 028 to 030
Errors 034 to 036
· Surge fault
· Control fault
Your Solar Inverter continuously monitors
the quality of the AC grid. If there are high
voltage peaks in the grid, the Solar Inverter
will stop the injection and try to restart.
If such a surge impulse is detected at
energy unit 3, for example, «error 030»
will be flagged.
Your Solar Inverter is equipped with a self-
monitored micro controller as a standard
feature. If a fault occurs in the control
sequence, the Solar Inverter will stop the
injection and will only restart when the
fault has been eliminated. If a fault occurs
in the control circuit board of the third
energy unit (upper energy unit), for exam-
ple, «error 036» will be flagged.
142
Download from Www.Somanuals.com. All Manuals Search And Download.
There are two «D302» and «D304» LEDs
each on the three control circuit boards;
they describe the current status of the
Solar Inverter:
on
Solar Inverter is operating normally
LED green
Led red
off
blinking Solar Inverter has detected a fault
blinking
LED green
LED red
GB
off
on
Internal control fault
Led green
LED red
Illustr.: Operation indicator LED
143
Download from Www.Somanuals.com. All Manuals Search And Download.
3.8 Error Diagnosis
You can look up error causes yourself in
the following list. Select the occurred error,
and read the «Remedies» to find out how
to eliminate it.
Error
Causes
Remedies
Errors 001 to 003 The maximum DC voltage
Check the rating of your PV generator.
DC overvoltage
has been exceeded.
Reduce the number of modules in the
DC inlet concerned, and recommission
the system.
Too many modules are
connected in series.
Errors 004 to 006 The grid frequency is outsi-
Frequency fault de the admissible range.
Ask your power supply company about
the stability and design of the grid.
Errors 007 to 009 The maximum admissible
The installation site is not suitable.
Overheating
ambient temperature of
40°C has been exceeded.
Please select a different installation site.
If contamination is blocking the cooling
system, clean the Solar Inverter.
The required air circulation
was not considered during
installation.
144
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
Objects have been deposi-
ted on the heat sink,
Remove the objects.
obstructing the convection.
Errors 010 to 012 The grid voltage of the
Ask your power supply company about
the stability and design of the grid.
Grid under-
injecting phase is too low.
The Solar Inverter monitors
the lower and upper admis-
sible grid voltage limits. If
the voltage drops below the
voltage 1-phase
Check the rating of your grid connection
(power meter) or the grid injection
point to your power supply company.
lower limit (U
= 184 V),
min
the Solar Inverter will auto-
matically switch off and will
only restart when the volta-
ge value rises above the
lower limit again. The shut-
down can already be trig-
gered if the voltage drops
below the lower limit for a
short time.
Errors 013 to 015 The grid voltage of the
Grid overvoltage injecting phase is too high.
Ask your power supply company about
the stability and design of the grid.
1-phase
The Solar Inverter monitors
the lower and upper admis-
sible grid voltage limits.
145
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
If the voltage exceeds the
upper limit (U
= 264 V),
max
the Solar Inverter will auto-
matically switch off and will
only restart when the volta-
ge value drops below the
upper limit again. The shut-
down can already be trig-
gered if the voltage drops
below the lower limit for
a short time.
The cable cross-section of
the AC supply line to the
Check the rating of your grid connection
(power meter) or the grid injection point
Solar Inverter is insufficient. to your power supply company.
Your solar system injects
electricity into an insuffi-
ciently rated spur line.
Ask your power supply company about
the stability and design of the grid.
146
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
Error 016
The grid voltage is too low.
The Solar Inverter monitors
the lower and upper admis-
sible grid voltage limits in
3-phases. If the voltage
Ask your power supply company about
the stability and design of the grid.
Grid under-
voltage 3-phase
drops below the lower limit
(U
= 184 V), the Solar
min
Inverter will automatically
switch off and will only
restart when the voltage
value rises above the lower
limit again. The shutdown
can already be triggered if
the voltage drops below the
lower limit for a short time.
Errors 017 to 019 The AFI fault is flagged if
AFI fault current
The entire PV system must be checked
fault current has penetrated for insulation faults.
the PV system and the Solar
Inverter has subsequently
disconnected from the grid.
147
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
Errors 020 to 022 During start-up, the Solar
Check your PV system for insulation
faults.
Insulation fault
Inverter has detected an
insulation fault in the PV
system.
Errors 023 to 025 The Solar Inverter has detec- Restart the Solar Inverter. Should the
DC injection
ted a DC share > 1 A in the
grid current.
fault still occur, please call the technical
hotline. The phone number is on the
back of the user manual.
Error 026
Isolated opera-
tion
Failure of one or more of
Check the grid phases L1, L2, and L3.
the grid phases L1, L2, or L3.
The position of the indivi-
dual phase conductors in
relation to each other has
moved beyond the admis-
sible tolerances.
Ask your power supply company about
the stability and design of the grid.
148
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
Error 027
The grid voltage is too high. Ask your power supply company about
Grid overvoltage
3-phase
The Solar Inverter monitors
the lower and upper admis-
sible grid voltage limits in
3-phases. If the voltage
exceeds the upper limit
the stability and design of the grid.
(U
= 264 V), the Solar
max
Inverter will automatically
switch off and will only
restart when the voltage
value drops below the
upper limit again. The shut-
down can already be trig-
gered if the voltage rises
above the upper limit for
a short time.
Errors 028 to 030 The Solar Inverter has detec- The Solar Inverter will automatically
Surge fault
ted a high voltage peak in
the injecting phase.
restart when the error has been elimina-
ted. Should the error occur often, please
consult your power supply company.
149
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
Errors 031 to 033 The grid voltage of the
The grid impedance of your grid connec-
ting point is too high.
Grid overvoltage
> 10 %
injecting phase is too high.
The Solar Inverter monitors
Ask your power supply company about
the lower and upper admis- the stability and design of the grid.
sible grid voltage limits.
If the voltage exceeds the
upper limit by 10 % (U
=
max
253 V), the Solar Inverter
will automatically be discon-
nected from the grid after
10 minutes (in compliance
with E DIN VDE 0126-1-1).
The cable cross-section of
the AC supply line to the
Check the rating of your grid connection
(power meter) or the grid injection point
Solar Inverter is insufficient. to your power supply company.
Your PV system injects elec-
tricity into an insufficiently
rated spur line.
Ask your power supply company about
the stability and design of the grid.
Errors 034 to 036 The self-monitoring Solar
Control error
Please call the technical hotline. The
Inverter has detected a con- phone number is on the back of the
trol fault. user manual.
150
Download from Www.Somanuals.com. All Manuals Search And Download.
Error
Causes
Remedies
Error 038
The back-up battery on the
interface circuit board is
empty.
Have the battery (button cell) exchanged
by a qualified person. The battery is on
the LCD display circuit board.
Back-up battery
empty
Display is blank,
The display contrast is bad,
That can happen if the ambient tempera-
ture is high. As soon as the temperature
drops, the display will work properly
again. That does not affect the injection
of electricity.
despite sufficient because the temperature is
injection
high.
The display circuit board is
not supplied with electricity.
Make sure the ribbon cable between
the display circuit board and the control
circuit board is not loose. For this pur-
pose, switch the Solar Inverter off, and
disconnect the AC and DC supply.
When doing so, please observe chapter
2.1 «Safety Instructions».
The PV generator is (partly)
covered with snow.
Clear the snow off the PV generator,
or wait until it has melted.
151
Download from Www.Somanuals.com. All Manuals Search And Download.
152
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 Appendix
1853
Download from Www.Somanuals.com. All Manuals Search And Download.
4.1 Tyco Solarlok Connectors
!
ꢀ
· Tyco Solarlok connectors may only be
connected to permanent lines!
Illustr.: Manual crimping tool for assembly
of Tyco Solarlok connectors
· They may not be disconnected under
load!
Contamination of any kind (dust, moisture,
etc.) has a negative effect on the working
order of the connector system over its aspi-
red service life. That especially applies to
the working order of the seals and the
crimping of the contacts. Therefore, make
sure everything is clean during assembly.
· For this purpose, interrupt the electric
circuit at a suitable point! Put a corre-
sponding sticker on the lines near the
Tyco Solarlok connector!
· To avoid an electric shock, always
disconnect the Tyco Solarlok connec-
tors from all other voltage sources
during preparation!
Illustr.: Tyco Solarlok connectors
154
Download from Www.Somanuals.com. All Manuals Search And Download.
With Tyco Solarlok connectors, different
kinds of annular contacts are used for dif-
ferent conductor cross-sections. Make sure
to use the right tools for these cross-sec-
tions. The enclosed Tyco Solarlok connec-
tors are equipped with annular contacts
for a cable cross-section of 4 mm. The
enclosed seals have an internal diameter of
6 mm (for lines with a cladding diameter
of 5.3 to 6.2 mm) and 8 mm (for lines with
a cladding diameter of 7.2 to 8.0 mm).
Make sure to use a seal that fits the clad-
ding diameter of the cable used.
1. Bare the de-energised line by 8 mm
2. Crimp the annular contact
3. Slide the gland, the compression sleeve,
and the seal onto the line
4. Engage the contact in the connector
housing
GB
5. Screw the lock nut on
6. Tightening torque for the cable gland:
1.5 Nm
When installing the Tyco Solarlok connec-
tors, proceed in the following order:
155
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 List of Special Terms and Abbreviations
Designation
AC
Description
Alternating Current: grid current
AFI, RCD
Operator protection in the event of residual currents
AFI: Universal Sensitive Residual Current
RCD: Residual Current Device
DC
Direct Current
PV generator side of the solar inverter
EMC
EB
IC
Electromagnetic Compatibility
Electricity Board
Interface Converter
IP
Identification of class of protection against external
environ-mental influences (penetration of water and
mechanical foreign bodies)
kW
Kilowatt
LCD
Liquid Crystal Display
156
Download from Www.Somanuals.com. All Manuals Search And Download.
Designation
Description
MPP
Maximum Power Point
Resistance of grid, impedance
Temperature sensor
Photovoltaic
Grid impedance
PT
PV
GB
PV generator switch
DC load break switch to cut off the PV generator
from the solar inverter
157
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3 Technical Data NT 10000
Model
Solar Inverter NT 10000
7000–12000 Wp
Recommended solar generator output
11000 W
Nominal input
DC
20 W
< 0.3 W
7 W
400 V
350 <= UMPP <= 750 V
850 V
420 V
Standby consumption
Night consumption
Injection starts from
Nominal voltage
UMPP voltage range
No-load voltage
Turn-on voltage
340 V
Turn-off voltage
Maximum current
Nominal current
Number of inlets
10 A per MPP multitracking inlet
9 A per MPP multitracking inlet
1 per MPP multitracking inlet;
3 altogether
96.4 percent (with ventilator operation)
95.9 percent (with ventilator operation)
yes
Maximum efficiency level
European efficiency level (weighted)
®
HERIC topology
10000 W
10000 W
50 Hz
AC Nominal output continuous operation Pn
Maximum output Pp
Nominal frequency
400 V
Grid voltage
-20 to +15 percent
14.5 A
18.2 A
< 3 percent
approx. 1
sine
Grid voltage tolerance range
Nominal current per phase
Max. current per phase
Distortion factor with Pn
Reactive power factor (cos phi)
Current waveform
158
Download from Www.Somanuals.com. All Manuals Search And Download.
Grid voltage monitoring
Earth-fault monitoring
Three phase according to E DIN VDE 0126-1-1
AFI (universal sensitive) according to E DIN
VDE 0126-1-1
Insulation monitoring
Yes, according to E DIN VDE 0126-1-1
Frequency monitoring
Yes, according to E DIN VDE 0126-1-1
DC monitoring
Yes, according to E DIN VDE 0126-1-1
Outlet characteristics
Current source
Grid connection fuse rating
Required number of phases per grid connection
Number of injection phases (230 V single-phase)
3 x 25 A
3
3
Data interfaces
Sensor interfaces
Display
RS232, RS485, USB
Irradiation, temperature
LCD, 2 x 16 characters, 100 x 25 mm screen size
Level of protection against environmental factors
Max. relative air humidity
Cooling
Ambient temperature (Celsius)
Dimensions (height x width x depth)
Weight
IP 54
95 percent
Ventilator above back panel, 2-chamber system
-25° C to 40° C
max. 805 x 500 x 175 (height x width x depth)
30 kg (without assembly frame)
Subjekt to technical changes.
159
Download from Www.Somanuals.com. All Manuals Search And Download.
4.4 Conformity and Safety Declarations
Declaration of Conformity to EU Low Voltage Directive 73/23/EEC, Appendix III B
We hereby declare that the product described below, including the required accessories,
conforms to the provisions of EU Directive 73/23/EEC following 93/68/EEC:
Solar Inverter
Product
Sunways AG, Photovoltaic Technology
Macairestr. 3-5, D -78467 Konstanz, Germany
Sunways NT 10000
Manufacturer
Type
15 September 2005
As from manufacturing date
Applied standards
Standard
Title
EN 50178, EN 60950
Electronic equipment for use in power
installations
Edition
1998
Comments
This product is a component, which is designated for the installation in a PV system and therefore only can correspond to the
guidelines for end devices, machines or systems depending on where it is installed in the overall PV system. The assessment of
the electrical and mechanical safety and the environmental influences (foreign bodies, moisture) must follow in the installed
condition in the overall PV system. In the installed condition, the EMC characteristics of this product can change. Therefore for
the overall PV system, a check of the EMC characteristics through the final product manufacturer is practical. Changes reserved.
The currently valid issue is available upon request.
Constance, 13 Sept. 2005
Place, date
Roland Burkhardt, Executive Board
160
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity to EMC Directive 89/336/EEC, Including Changes 91/263/EEC
and 93/68/EEC
We hereby declare that the product described below conforms to the provisions of EU
Directive 89/336/EEC (EMC Directive with changes 91/263/EEC and 93/68/EEC):
Solar Inverter
Product
Sunways AG, Photovoltaic Technology
Macairestr. 3-5, D -78467 Konstanz, Germany
Sunways NT 10000
Manufacturer
GB
Type
15 September 2005
As from manufacturing date
Applied standards
Standard EN 50082-2 (EN 61000-4-2, -4-3, -4-4, -4-6, -4-8)
EN 55014-1; EN 55011; EN 61000-3-2;
EN 61000-3-3; E DIN VDE 0126-1-1
Comments
The adherence to the EMC guideline presupposes an installation of the components in the system or machine, which is suitable
for EMC. The installation instructions in the technical documents are to be observed. The checks follow for an installation,
which is typical for the system on a measuring station, which conforms to the norms. The legal requirements for the stability
and the emitted interference, limit values and norms are listed in the documentation named above. The Sunways products are
intended for the installation in a PV system. The check results are not transferable in all cases to the installed condition in the
PV system. This declaration therefore does not contain the assurance of EMC characteristics of the final product. Changes reser-
ved. The currently valid issue is available upon request.
Constance, 13 Sept. 2005
Place, date
Roland Burkhardt, Executive Board
161
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Clearance / Certificate of Compliance with the Directives on the Connection and
Parallel Operation of In-Plant Generation Systems to the Low-Voltage Grid (VDEW
[German Electricity Association], 4th Edition 2001)
We hereby declare that the following product complies with the provisions of the appli-
cable VDE [German Association for Electrical, Electronic & Information Technologies]
directive for operation parallel to the grid. In particular, the directives for connection and
parallel operation of in-plant generation systems to the low-voltage grid of the energy
supply company (VDEW 4th edition 2001) and DIN 0838 are complied with.
Solar Inverter
Product
Sunways AG, Photovoltaic Technology
Macairestr. 3-5, D -78467 Konstanz, Germany
Sunways NT 10000
Manufacturer
Type
15 September 2005
As from manufacturing date
Applied standards
Norm
Title
In-Plant Generation Systems to the
Low-Voltage Grid
4th edition 2001
Edition
Explanations
Sunways Solar Inverters of series NT 10000 are Solar Inverters that inject in three-phases and are not capable of isolated opera-
tion. The NT 10000 consists of three single-phase inverters with a three-phase voltage monitoring system that inject into different
phases. These integrated inverters control their phase angle independently of each other. They are equipped with a voltage-
monitoring system and a three-phase monitoring system for any reduction of the linked voltage, in accordance with section 2.4.2
of the VDEW directive (4th edition 2001). Therefore, no always accessible isolating point is required (see section 2.1.2 Schaltstelle
mit Trennfunktion [Control Point with Disconnection Function]). A routine test is carried out with each device to make sure the
turn-off values of the three-phase voltage reduction protection are maintained. Subject to changes. Currently valid edition availa-
ble at request.
Constance, 13 Sept. 2005
Place, date
Roland Burkhardt, Executive Board
162
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5 Terms and Conditions of
Guarantee
inform us beforehand, stating your name,
address, phone number, email address (if
applicable), and the serial number. The
phone number is on the back of the user
manual.
· Duration of Guarantee
The duration of guarantee is five years,
starting from the day the Solar Inverter
is purchased by the end user. The gua-
rantee chard enclosed with the device
must be completed and sent back to
Sunways AG.
The Solar Inverter may only be shipped
with the prior approval of Sunways AG.
The approval will be granted as soon as
the completed fault protocol has arrived,
stating the occurred fault and the way you
would like the guarantee claim to be pro-
cessed. Devices sent to Sunways AG
without prior notification cannot be
accepted and repaired.
GB
Please keep the original receipt with the
date of purchase and the serial number.
In case of a guarantee claim, it is requi-
red as evidence, together with the gua-
rantee card.
· Conditions
The time required to correct the fault
must be granted. Sunways AG will try to
correct the fault within 14 days after
having received the device. If that is not
possible, we will let you know the reason
and when the fault will be corrected.
Within the guarantee period, the Solar
Inverter will be repaired in the factory in
Constance, Germany, without material or
labour being charged. Assembly costs
shall be borne by the customer, unless
something else has been agreed on.
Please keep the original packaging, even
after the guarantee period has run out.
Forwarding companies may only accept
the Solar Inverter if it is in the transport-
proof original packaging. Therefore, please
let us know if you have lost the original
The completed guarantee card must be
sent to Sunways AG, Constance, within
seven days after purchase.
In case of a guarantee claim, please
163
Download from Www.Somanuals.com. All Manuals Search And Download.
packaging, prior to having the device pic-
ked up. We will be glad to send you a new
packaging against payment.
Any further-reaching or other claims for
direct or indirect damage, especially claims
for compensation including ones for positi-
ve breach of contract are excluded, unless
they are compellingly prescribed by law.
·
Exclusion of Liability
Claims and liability for damage directly or
indirectly caused by the following reasons
are excluded:
· interventions, changes, and repair
attempts
· insufficient ventilation
· force majeure (e. g. lightning strike,
water damage, vandalism, fire,
overvoltage, storm, etc.)
· inappropriate transportation
· non-compliance with applicable regula-
tions, or wrong installation/commissio-
ning
· leakage of overvoltage of the varistors
on the DC side at the PV generator
164
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6 General Exclusion of Liability
All rights reserved. © Sunways AG
Although the accuracy and completeness
of the information in this manual have
carefully been checked, no liability what-
soever can be accepted for mistakes or
omissions.
The products named in the title are protec-
ted by copyright and are sold under license.
Without a prior written permission of
Sunways AG and the Sunways licensors, no
part of this document may be reproduced
in any form.
· Sunways AG reserves the right to chan-
ge the hardware and software features
described here at any time, without
prior notification.
Registered trademark
GB
Sunways NT 10000 and the Sunways logo
are registered trademarks of Sunways AG,
Constance, Germany.
· Without the prior written approval of
Sunways AG, this manual may not be
duplicated, transferred, copied, or trans-
lated into other languages in any form
or by any means, in part or in whole.
· Sunways AG does not accept responsibi-
lity for damage caused by false or lost
data due to wrong operation or mal-
functions of the Solar Inverter, the soft-
ware, additional devices, or PCs.
®
HERIC is a registered trademark of
Fraunhofer Gesellschaft, Munich, Germany.
165
Download from Www.Somanuals.com. All Manuals Search And Download.
Sunways AG
Photovoltaic Technology
Macairestraße 3 - 5
D -78467 Konstanz
Telefon +49 7531 996770
Fax +49 7531 99677444
E-Mail info@sunways.de
Technische Hotline +49 7531 99677577
Download from Www.Somanuals.com. All Manuals Search And Download.
|