FUNCTIONS  
1. Prevents mold growth on clothing, cupboards, doors and drawers.  
2. Prevents condensation on ceiling, walls and windows.  
3. Dehumidifying is effective on moisture sensitive items like musical instruments, cameras,  
computers, etc.  
4. Removes dampness from bookshelves and closets.  
SAFETY NOTES  
1. Do not connect unit to any damaged AC electrical socket.  
2. Ensure removable covers and containers are correctly fitted before switching on unit.  
3. Always switch unit off when not in use and before unplugging.  
4. Do not use in the following locations:  
 Next to or near a heat source (radiator, heater, dryer, etc.)  
 Area where oil or water is likely to splash.  
 Under direct sunlight.  
 Near a bath, shower or swimming pool.  
 In a greenhouse.  
5. Never insert your finger or other foreign objects into grills or openings. Take special care to  
warn children of these dangers.  
6. Allow unit to stand upright for at least 24 hours before initial operation and after moving or  
tilting the unit. Store the unit upright to maintain the compressor in proper working condition.  
7. Always unplug the unit before cleaning and maintenance.  
8. Do not cover the unit and it air inlets/outlets.  
9. Do not spray insecticides or any other flammable sprays on the machine.  
10. Do not spray water on the unit.  
11. There are no user serviceable parts. Should the unit or supply cord become damaged,  
contact the manufacture immediately.  
12. Empty the water tank before moving the dehumidifier.  
13. This unit is equipped with auto-defrosting, which operates when the evaporator generates  
frost. This function ensures continuous operation when the temperature is down to 41F.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAME OF PARTS  
CONTROL PANEL  
1. POWER Button: Press once to turn unit ON, unit will begin operating in dehumidifying mode  
at original factory setting (60%RH). Press again to turn unit OFF.  
2. CONTINUOUS Button: When unit is in operation, press this button to set CONTINUOUS  
DEHUMIDIFYING mode.  
3. TURBO Button: Press this button to set unit in high fan speed.  
4. NORMAL Button: Press this button to set unit in low fan speed.  
5. POWER Indicator: Will flash slowly when power is connected at the socket (initial power).  
Indicator lights up when unit is turned ON and dark if unit is OFF.  
6. CONTINUOUS Indicator: Lights up when CONTINUOUS DEHUMIDIFYING mode is  
selected.  
7. FULL Indicator: Lights up when bucket is full, unit will stop operating.  
8. HUMITIDY + Button: Press this button to increase the humidity setting. Range of  
adjustment is from 35% ~ 80% RH.  
9. HUMIDITY - Button: Press this button to decrease the humidity setting. Range of  
adjustment is from 80% ~ 35% RH.  
10. TURBO Indicator: Lights up when TURBO button is pressed, unit will run in high fan speed.  
11. NORMAL Indicator: Lights up when NORMAL button is pressed, unit will run in low fan  
speed.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL SPECIFICATIONS  
MODEL  
SD-30E  
SD-40E  
40 pints per day  
115V / 60Hz  
52.A  
SD-60E  
Dehumidifying Capacity  
Power Supply  
Current  
30 pints per day  
60 pints per day  
4.5A  
6.8A  
780W  
Power Consumption  
490W  
560W  
5 ~ 32C / 41 ~ 89F  
13 ~ 35C / 55 ~ 95F  
Working Environment  
25% RH and above  
Water Tank Volume  
Net Weight  
5 liters / 11 pints  
10 liters / 21 pints  
55lbs  
32lbs  
33lbs  
Dimension  
13.4 L x 10 W x 19.9 H in.  
13.4 L x 10 W x 19.88 H in.  
** Capacity will vary according to actual room ambient temperature and humidity conditions.  
INSTALLATION  
Place the dehumidifier on a flat surface and in a location where the air inlets and outlets will not  
be obstructed. Do not install underneath desks or inside cupboards, as this will restrict the  
airflow. Keep unit at least 40 inches away from televisions and radios as the unit may disrupt the  
image or sound. Maintain a minimum clearance of 20cm (7.5 in.) to the front and rear of unit.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
Operating Conditions:  
 This unit is designed to operate with a working environment between 41 ~ 90F.  
 If the unit has been switched off, please wait 3 minutes before switching on again. If  
switched on immediately, allow 3 minutes for unit to resume correct operation.  
 Do not connect unit to a multiple socket outlet with other electrical appliances.  
 Select a suitable location, with easy access to an electrical outlet.  
 Plug the unit into an 115V~ 60Hz electrical socket with earth connection.  
 Make sure the water tank is correctly fitted or unit will not operate.  
Turning the unit ON or OFF:  
1. Plug the cord to a proper power requirement. The unit’s computer system will have a self-  
check. If normal, POWER indicator will flash at 0.5Hz. Press the POWER button to start  
operation. Unit will begin to operate at 60% humidity setting, press + or to change humidity  
setting.  
2. Press CONTINUOUS button to run in continuous dehumidifying mode. In continuous mode,  
+ or buttons are disabled.  
3. Press POWER button again to turn off unit. You do not need to unplug the cord except when  
unit will not be used for a long period of time.  
OPERATION  
Water Tank:  
 When water tank is full, unit will stop operating and FULL indicator light will flash.  
 Never remove the water tank while unit is in operation.  
 Grip the left and right handles securely and carefully pull straight out. Do not place tank on  
the floor, as the bottom of the tank is not even and will tilt. Empty the water and gently push  
the tank all the way in. Ensure the tank is correctly positioned.  
 The unit will re-start when the tank is restored in its correct position.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Continuous Drainage:  
 Remove the plastic cover located at the rear of the unit.  
 Push the drain hose into the drain hole (see image below)  
 Remove the water tank and securely attach the drain hose to the connector (see image  
below)  
 The hose should be smooth and without bends or kinks.  
 Place the end of the hose to a suitable drainage facility.  
MAINTENANCE  
Important!  
 Be sure to unplug the unit before cleaning.  
 Do not use petrol, thinners or other chemical agents to clean the unit as this may damage  
the unit.  
 Do not wash the unit directly under water. The electrical components inside may be  
damages and cause the unit to become unsafe.  
Air Filter  
Clean the air filter at least once every two weeks to prevent impaired performance.  
 Pull the air filter out as shown in Fig. A.  
 Wash the air filter with clean water and allow dry completely.  
 Replace cleaned filter as shown in Fig. C.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Housing  
Use a soft, clean cloth to wipe the surface. Do not use water as this may cause an electrical  
fault or shock hazard.  
Water Tank  
Wash the tank using warm water and neutral detergent. Rinse and allow dry, replace when dry.  
Power Cord  
Wrap the cord and bundle it with a band.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE SHOOTING  
BEFORE COTACTING THE MANUFACTURER, PLEASE CHECK THE FOLLOWING  
POSSIBILITIES.  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
 Switch power ON  
 Restore power cord  
 Re-position water tank  
 Empty water tank  
 After defrosting, unit will  
dehumidify again  
 Power is OFF  
 Power cord is unplugged  
 Water tank not fitted correctly  
 Water tank is full  
Unit fails to operate  
 Defrosting  
 Blocked air filter  
 Wash nylon filter  
 Close windows and doors  
 Remove obstacles  
 Reposition unit  
Performance decreased  
Unit is noisy  
 Room windows and doors are open  
 Obstacles in air outlet or inlet  
 Unstable setting of unit  
 Blocked filter  
 Wash nylon filter  
The following displays indicate an error or problem:  
Display code  
Problem  
What to do  
Unit will automatically restart  
after defrosting  
Empty the tank  
Turn off unit and contact  
Sunpentown.  
P1  
P2  
E1  
Defrosting starts  
Water tank is full  
Humidity sensor is off or short-  
circuit  
Temperature sensor is off or  
short-circuit  
Turn off unit and contact  
Sunpentown.  
E2  
If you still cannot solve the problem after trying the above, unplug unit and contact  
Sunpentown Int’l Inc.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Your Guarantee  
If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of  
purchase, it will be repaired free of charge.  
This guarantee is subject to the following terms:  
 Sunpentown must be notified of the fault.  
 Proof of purchase must be presented to Sunpentown’s nominated representative.  
 The warranty will be void if the product if modified, misused or repaired by an unauthorized person.  
 The warranty after repair will not be extended beyond the original one-year period.  
 All replacement parts will be new or reconditioned.  
 Parts, which are replaced, become the property of Sunpentown.  
 The warranty applies for the use of the product in the USA only.  
What is NOT COVERED:  
 Warranty does not include freight charges.  
 Incidental or consequential damage caused by possible defects with this product.  
 Damage to product caused by improper power supply voltage, accident, fire, floods or acts of nature.  
 Failure of product resulting from unauthorized modifications to the product.  
 Improper installation or failure to perform the necessary maintenance.  
This GUARANTEE is in addition to your Statutory Rights  
SUNPENTOWN INTERNATIONAL INC.  
21415 Baker Parkway, City of Industry, CA 91789-5236  
909-468-5288  
Fax:909-468-5279  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Stereo System CD CH1500 User Manual
Snapper Lawn Aerator 3537 User Manual
Soleus Air Air Conditioner KFTHP 09 User Manual
Sony Ericsson Cell Phone Z520a User Manual
Sony Portable CD Player CFD S400 User Manual
Stamina Products Home Gym 55 5510 User Manual
Star Manufacturing Oven 314HX User Manual
Sterling Air Conditioner 7200 A User Manual
Sterling Marine Safety Devices SFC K 40 User Manual
Sunbeam Iron 122015 User Manual