™
Sun GigaSwift Ethernet
Adapter Installation and
User’s Guide
Sun Microsystems, Inc.
901 San Antonio Road
Palo Alto, CA 94303-4900 U.S.A.
650-960-1300
Part No. 816-1702-11
February 2003, Revision A
Send comments about this document to: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Compliance Statements
Your Sun product is marked to indicate its compliance class:
•
•
•
•
Federal Communications Commission (FCC) — USA
Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada
Voluntary Control Council for Interference (VCCI) — Japan
Bureau of Standards Metrology and Inspection (BSMI) — Taiwan
Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the
product.
FCC Class A Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is
not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required
to correct the interference at his own expense.
Shielded Cables: Connections between the workstation and peripherals must be made using shielded cables to comply with
FCC radio frequency emission limits. Networking connections can be made using unshielded twisted-pair (UTP) cables.
Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the
authority granted to the user by the FCC to operate this equipment.
FCC Class B Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/ television technician for help.
Shielded Cables: Connections between the workstation and peripherals must be made using shielded cables in order to
maintain compliance with FCC radio frequency emission limits. Networking connections can be made using unshielded
twisted pair (UTP) cables.
Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the
authority granted to the user by the FCC to operate this equipment.
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
ICES-003 Class A Notice - Avis NMB-003, Classe A
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
ICES-003 Class B Notice - Avis NMB-003, Classe B
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
iv
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
BSMI Class A Notice
The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance
label.
v
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity
Compliance Model Number:
Product Family Name:
GCC PCI
Sun GigaSwift Ethernet UTP Adapter (X1150A)
EMC
European Union
This equipment complies with the following requirements of the EMC Directive 89/ 336/ EEC:
EN55022:1998/ CISPR22:1997
EN55024:1998 Required Limits (as applicable):
EN61000-4-2
Class A
4 kV (Direct), 8 kV (Air)
EN61000-4-3
3 V/ m
EN61000-4-4
1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
EN61000-4-5
1 kV AC Line-Line and Outdoor Signal Lines
2 kV AC Line-Gnd, 0.5 kV DC Power Lines
EN61000-4-6
EN61000-4-8
3 V
1 A/ m
Pass
Pass
Pass
EN61000-4-11
EN61000-3-2:1995 + A1, A2, A14
EN61000-3-3:1995
Safety
This equipment complies with the following requirements of the Low Voltage Directive 73/ 23/ EEC:
EC Type Examination Certificates:
EN60950:1992, 2nd Edition, Amendments 1, 2, 3, 4, 11
Supplementary Information
This product was tested and complies with all the requirements for the CE Mark.
/ S/
/ S/
Dennis P. Symanski
DATE
Peter Arkless
DATE
Manager, Compliance Engineering
Sun Microsystems, Inc.
901 San Antonio Road, MPK15-102
Palo Alto, CA 94303-4900 U.S.A.
Tel: 650-786-3255
Quality Manager
Sun Microsystems Scotland, Limited
Springfield, Linlithgow
West Lothian, EH49 7LR
Scotland, United Kingdom
Fax: 650-786-3723
Tel: 0506-670000
Fax: 0506-760011
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity
Compliance Model Number:
Product Family Name:
GFC PCI
Sun GigaSwift Ethernet MMF Adapter (X1151A)
EMC
European Union
This equipment complies with the following requirements of the EMC Directive 89/ 336/ EEC:
EN55022:1998/ CISPR22:1997
EN55024:1998 Required Limits (as applicable):
EN61000-4-2
Class A
4 kV (Direct), 8 kV (Air)
EN61000-4-3
3 V/ m
EN61000-4-4
1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
EN61000-4-5
1 kV AC Line-Line and Outdoor Signal Lines
2 kV AC Line-Gnd, 0.5 kV DC Power Lines
EN61000-4-6
EN61000-4-8
3 V
1 A/ m
Pass
Pass
Pass
EN61000-4-11
EN61000-3-2:1995 + A1, A2, A14
EN61000-3-3:1995
Safety
This equipment complies with the following requirements of the Low Voltage Directive 73/ 23/ EEC:
EC Type Examination Certificates:
EN60950:1992, 2nd Edition, Amendments 1, 2, 3, 4, 11
Supplementary Information
This product was tested and complies with all the requirements for the CE Mark.
/ S/
/ S/
Dennis P. Symanski
DATE
Peter Arkless
DATE
Manager, Compliance Engineering
Sun Microsystems, Inc.
901 San Antonio Road, MPK15-102
Palo Alto, CA 94303-4900 U.S.A.
Tel: 650-786-3255
Quality Manager
Sun Microsystems Scotland, Limited
Springfield, Linlithgow
West Lothian, EH49 7LR
Scotland, United Kingdom
Fax: 650-786-3723
Tel: 0506-670000
Fax: 0506-760011
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
x
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Product Overview
1
Hardware Overview
1
Sun GigaSwift Ethernet MMF Adapter
LED Displays
Sun GigaSwift Ethernet UTP Adapter
LED Displays
Hardware and Software Requirements
Patch Requirements
2
2
3
3
5
5
2. Installing the Adapter
9
Installing the Driver Software
9
▼
To Install Driver Software for Solaris 2.6 Operating Environments 12
Verifying Patches 12
Installing the Adapter Without Dynamic Reconfiguration 14
▼
▼
To Install the Adapter 14
To Verify the Installation 16
Setting the local-mac-addressProperty 19
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
▼
3. Network Configuration 25
▼
Installing the Solaris Operating Environment Over a GigaSwift Ethernet
▼
4. Configuring Driver Parameters 37
GigaSwift Ethernet Device Driver Parameters 37
Driver Parameter V 38
Operational Mode Parameters 39
Flow Control Parameters 40
Gigabit Link Clock Mastership Controls 42
Interpacket Gap Parameters 42
Interrupt Parameters 44
Random Early Drop Parameters 45
PCI Bus Interface Parameters 46
Setting ceDriver Parameters 47
Setting Parameters Using the nddUtility 47
▼
To Specify Device Instances for the nddUtility 48
Setting Parameters Using the ce.confFile 51
To Set Driver Parameters Using a ce.confFile 52
▼
Usability Enhancements to the Driver 53
xii
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Configuring VLANs 63
Configuring VLANs 65
▼
A. Specifications 69
Connectors 69
B. Diagnostic Software and Troubleshooting Issues 73
SunVTS Diagnostic Software 73
Using the OpenBoot PROM FCode Self-Test 74
▼
Running the Ethernet FCode Self-Test Diagnostic 74
Known Incompatibilities with Pre-IEEE 802.3z Network Switches 76
▼
▼
To Set Autonegotiation to offfor a SunSwitch or an Alteon ACE 110
Equipment 77
Non-Specific Issues 78
Problem with DR Attach on Sun Enterprise Platforms 79
Index 81
Contents
xiii
Download from Www.Somanuals.com. All Manuals Search And Download.
xiv Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Figures
FIGURE 5-1
FIGURE 5-2
FIGURE A-1
FIGURE A-2
Sun GigaSwift Ethernet MMF Adapter
Sun GigaSwift Ethernet UTP Adapter
Connecting the Fiber Optic Cable 15
Cat-5 Twisted-Pair Cable 16
2
3
Example of Servers Supporting Multiple VLANs with Tagging Adapters 64
Ethernet Tag Header Format 66
Sun GigaSwift Ethernet MMF Adapter Connector 69
Sun GigaSwift Ethernet UTP Adapter Connector 70
xv
Download from Www.Somanuals.com. All Manuals Search And Download.
xvi
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Tables
TABLE 4-11
TABLE 4-12
TABLE A-1
TABLE A-2
Front Panel Display LEDs for the MMF Adapter
Front Panel Display LEDs for the UTP Adapter
Files and Directories on the CD-ROM 10
Device Link Parameters 34
2
4
link-clockCapabilities for Link Up 34
ceDriver Parameter, Status, and Descriptions 38
Operational Mode Parameters 39
Read-Write Flow Control Keyword Descriptions 41
Forced Mode Parameter 42
Parameters Defining enable-ipg0and ipg0 43
Read-Write Interpacket Gap Parameter Values and Descriptions 43
RX Blanking Register for Alias Read 44
RX Random Early Detecting 8-Bit Vectors 45
PCI Bus Interface Parameters 46
Read-Only ceDevice Capabilities 54
Read-Only Link Partner Capabilities 55
Transmit and Receive Parameters 56
SC Connector Link Characteristics (IEEE P802.3z) 69
Cat-5 Connector Link Characteristics 70
xvii
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE A-3
TABLE A-4
TABLE A-5
TABLE B-1
Performance Sepcifications 70
Physical Characteristics 71
Power Requirements 71
Troubleshooting the GigaSwift Ethernet Adapter 78
xviii
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
The Sun GigaSwift Ethernet Adapter Installation and User’s Guide provides installation
instructions for both the Sun GigaSwift Ethernet UTP adapter and the Sun GigaSwift
Ethernet MMF adapter. This manual also describes how to configure the driver
software.
These instructions are designed for enterprise system administrators with experience
installing network hardware and software.
Chapter 1, provides a description of the adapter, including hardware and software.
Chapter 2, describes how to install the adapter in your system and how to verify that
it has been installed correctly.
Chapter 3, describes how to edit the network host files after the adapter has been
installed on your system.
Chapter 4, describes how to configure the driver parameters used by the Sun
Chapter 5, explains VLANs in detail and provides configuration instructions and
examples.
Appendix A, lists the specifications for the Sun GigaSwift Ethernet adapter.
Appendix B, provides an overview of the SunVTS diagnostic application and
instructions for testing the adapter using the onboard FCode selftest. There is also a
section outlining some common troubleshooting issues.
xix
Download from Www.Somanuals.com. All Manuals Search And Download.
Using UNIX Commands
This document may not contain information on basic UNIX commands and
procedures such as shutting down the system, booting the system, and configuring
devices.
®
See one or more of the following for this information:
■ Solaris Handbook for Sun Peripherals
■ AnswerBook2™ online documentation for the Solaris™ operating environment
■ Other software documentation that you received with your system
Typographic Conventions
Typeface
Meaning
Examples
AaBbCc123
The names of commands, files,
and directories; on-screen
computer output
Edit your.loginfile.
Use ls-ato list all files.
% You have mail.
What you type, when
contrasted with on-screen
computer output
% su
Password:
AaBbCc123
AaBbCc123
Book titles, new words or terms, Read Chapter 6 in the User’s Guide.
words to be emphasized
These are called class options.
You must be superuser to do this.
Command-line variable; replace To delete a file, type rmfilename.
with a real name or value
xx Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Shell Prompts
Shell
Prompt
C shell
machine_name%
C shell superuser
machine_name#
Bourne shell and Korn shell
Bourne shell and Korn shell superuser
$
#
Related Documentation
Application
Title
PCI Adapter Installation
Storage Device Installation
Your system installation or service manual
Your storage device installation or service manual
Dynamic Reconfiguration
Installation
Sun Enterprise 6x00, 5x00, 4x00, and 3x00 Systems
Dynamic Reconfiguration User’s Guide
Diagnostic Software
SunVTS User’s Guide
SunVTS Test Reference Manual
OpenBoot™ Commands
OpenBoot 3.x Command Reference Manual
Accessing Sun Documentation Online
You can view, print, or purchase a broad selection of Sun documentation, including
localized versions, at:
http://docs.sun.com/db?p=prod/net.hard
Preface
xxi
Download from Www.Somanuals.com. All Manuals Search And Download.
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can email your comments to Sun at:
Please include the part number (816-1702-11) of your document in the subject line of
your email.
xxii Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
1
Product Overview
This chapter provides a description of the Sun GigaSwift Ethernet adapter hardware
and software. This chapter includes the following sections:
■ “Hardware Overview” on page 1
■ “Hardware and Software Requirements” on page 5
■ “Patch Requirements” on page 5
■ “Product Features” on page 6
Hardware Overview
The adapter relieves congestion experienced at the backbone and server levels by
today’s networks, while providing a future upgrade path for high-end workstations
that require more bandwidth than fast Ethernet can provide.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Sun GigaSwift Ethernet MMF Adapter
The Sun GigaSwift Ethernet MMF adapter is a single-port gigabit Ethernet fiber
optics PCI Bus card. It operates in 1000 Mbps Ethernet networks only.
FIGURE 1-1 Sun GigaSwift Ethernet MMF Adapter
LED Displays
Four LEDs are displayed on the front panel of Sun GigaSwift Ethernet MMF adapter.
They are labeled on the front panel as shown in TABLE 1-1.
TABLE 1-1
Front Panel Display LEDs for the MMF Adapter
Label
Link
FDX
TX
Meaning if Lit
Color
Link is up
Green
Green
Green
Green
Link is in Full Duplex mode.
Link is transmitting
Link is receiving
RX
2
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Sun GigaSwift Ethernet UTP Adapter
The Sun GigaSwift Ethernet UTP adapter is a single-port gigabit Ethernet copper-
based PCI Bus card. It can be configured to operate in 10, 100, or 1000 Mbps Ethernet
networks.
FIGURE 1-2 Sun GigaSwift Ethernet UTP Adapter
LED Displays
A total of nine LEDs are displayed on the front panel of the Sun GigaSwift Ethernet
UTP adapter. They are labeled on the front panel as shown in TABLE 1-2.
The nine LEDs consist of a single purple LED and two sets of four green LEDs. Note
that all LEDs are sourced by the gigabit PHY except the last two LEDs. TXM and
RXM are sourced by the Sun GigaSwift Ethernet MAC ASIC. These LEDs are
Chapter 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Overview
3
equivalent to TX and RX of the PHY except that they indicate the state of the MAC
instead and can be used for diagnostic purposes to isolate a PHY or a MAC failure
on the board.
TABLE 1-2
Front Panel Display LEDs for the UTP Adapter
Label
Link quality
1000X
100X
10X
Meaning if On/Active
Gigabit link quality good
Gigabit link is up
Color
Source
PHY
PHY
PHY
PHY
PHY
PHY
PHY
MAC
MAC
Purple
Green
Green
Green
Green
Green
Green
Green
Green
100Mbt link is up
10Mbt link is up
FDX
Full Duplex Mode
PHY Transmitting data
PHY Receiving data
MAC transmitting data
MAC receiving data
TX
RX
TXM
RXM
4
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware and Software Requirements
Before using the Sun GigaSwift Ethernet adapter, make sure your system meets the
following hardware and software requirements:
Hardware and Software
Requirements
Hardware
Sun Ultra™ 5, 10, 60, 80
Sun Enterprise™ 220R, 250, 450, 3000/ 3500, 4000/ 4500, 5000/
5500, 6000/ 6500/ 6800, 10000, 15000
Sun Fire™ 280R, V480, V880
Sun Blade™ 1000
OpenBoot PROM
Revision 3.x
Operating environment Solaris 2.6, 7, 8, and 9 releases
Enterprise 3000, 4000, 5000, and 6000 series systems using the Sun GigaSwift
Ethernet adapter require a shielded twisted pair Ethernet cable.
Caution – Installing the Sun GigaSwift Ethernet adapter on the Enterprise 3000,
4000, 5000, and 6000 series systems is prohibited if option (X)1080A Sun Enterprise
Systems Interface card is already installed on the 2632A PCI I/ O board for these
platforms. Install the Sun GigaSwift Ethernet adapter on the next available 2632A
PCI I/ O card.
Patch Requirements
The software driver package provided on the CD ROM has the following patches
preinstalled.
■ Solaris™ 2.6 and 7 operating environments Patch-ID Number 112327-02
■ Solaris 8 operating environments Patch-ID Number 111883-07
The Solaris 8 2/ 02 release includes Patch-ID Number 111883-05. Subsequent versions
of the Solaris operating environment may include the correct version.
■ Solaris 9 operating environements Patch-ID 112817-05
Following are the current driver patch versions (at the time this document was
created):
Chapter 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Overview
5
■ Patch-ID Number 112327-07 for Solaris 2.6 and 7 operating environments
■ Patch-ID Number 111883-13 for Solaris 8 operating environments
Install the latest version of the Patch-ID Number for example, the dash number -07
becomes higher with each new version of the patch.
If you install Solaris 8 2/ 02 or any previous version of the Solaris operating
environment after installing the Sun GigaSwift Ethernet driver software, you must
install the latest version of the patch from the following web site:
http://sunsolve.sun.com
If the patch is not available on SunSolve, contact your local sales or service
representative.
Product Features
You can install or replace the Sun GigaSwift Ethernet adapter. You can also diagnose
a failure using the built-in diagnostic tools.
Key Protocols and Interfaces
The Sun GigaSwift Ethernet adapter is interoperable with existing Ethernet
equipment assuming standard Ethernet minimum and maximum frame size (64 to
1518 bytes), frame format, and compliance with the following standards and
protocols:
■ SNMP (limited MIB)
■ Full-duplex gigabit Ethernet interface
■ Low CPU utilization—Frees up server system resource and bandwidth
■ Dynamic reconfiguration (DR) and redundancy/ failover support
■ Full flow control support
■ Duplex SC fiber connector (850 nm, SX)
■ 33/ 66-MHz, 32- or 64-bit bus master
■ Universal dual voltage signaling (3.3V and 5V)
■ PCI Local Bus Rev 2.2-compliant (6.8-inch x 4.2-inch short card)
■ IPv4 and IPv6 support
■ Load balancing for RX packets among multiple CPUs
■ IEEE 802.1Q VLAN
■ IEEE 802.1P/ 802.1D Priority Tagging/ Quality Of Service
■ RAS support
■ Energy Star® support
6
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
2
Installing the Adapter
■ “Installing the Adapter Without Dynamic Reconfiguration” on page 14
■
■
■
“To Verify the Installation” on page 16
“Setting the local-mac-addressProperty” on page 19
“Rebooting the System” on page 20
■ “Installing the Adapter With Dynamic Reconfiguration” on page 21
Note – If you have a Sun Enterprise system that supports dynamic reconfiguration
(DR), refer to the Sun Enterprise Dynamic Reconfiguration User’s Guide and your
system’s documentation for further information about dynamic reconfiguration.
Installing the Driver Software
The Sun GigaSwift Ethernet Driver 1.0 Update 1 CD contains the driver software
required to operate the adapter. The Solaris 8 10/ 01 operating environment and
subsequent compatible releases include the Sun GigaSwift Ethernet driver software.
Refer to the documentation that shipped with the Solaris Supplement CD-ROM for a
listing of the available network drivers. Be sure to install the Sun GigaSwift Ethernet
driver for your version of the Solaris operating environment.
1. Become superuser.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Insert the Sun GigaSwift Ethernet Driver 1.0 Update 1 CD into a CD-ROM drive that
is connected to your system.
■ If your system is running Sun Enterprise Volume Manager™, it should
automatically mount the CD-ROM to the / cdrom/cdrom0directory.
■ If your system is not running Volume Manager, mount the CD-ROM as follows:
# mkdir /cdrom
# mkdir /cdrom/cdrom0
# mount -F hsfs -o ro /dev/dsk/c0t6d0s2 /cdrom/cdrom0
You will see the following files and directories in the
/cdrom/sun_gigaswift_ethernetdirectory or the
/cdrom/cdrom0directory, depending on how you mounted the CD-ROM.
TABLE 2-1
Files and Directories on the CD-ROM
File or Directory
Copyright
FR_Copyright
Docs/
Contents
U.S. copyright file
French copyright file
Contains PDF copy of the user manual
GigaSwiftEthernet/
Solaris_OS-VER/
Packages/
Contains the Sun GigaSwift Ethernet software packages
applicable to your version (OS-VER) of the Solaris software
• SUNWcea—32-bit adb macros
• SUNWceax—64-bit adb macros
• SUNWced.u—32-bit adapter driver
• SUNWced.u1—32-bit adapter driver for Solaris 2.6 Sun
Enterprise 10000
• SUNWcedx.u—64-bit adapter driver
• SUNWcedu—adapter driver headers
• SUNWcem—man pages (optional)
The optional VLAN packages for Solaris 8 only
• SUNWvld—VLAN utility routines
• SUNWvldx—VLAN utility routines (64-bit)
• SUNWvldu—VLAN utility headers
Note – If you intend to use VLAN, you must install VLAN packages when you
install the GigaSwift Ethernet software packages.
10
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Install the software packages by typing the following at the command line,
replacing the OS_VER with your version (2.6, 7, or 8) of the Solaris Operating
Environment:
#/usr/sbin/pkgadd -d /cdrom/cdrom0/GigaSwiftEthernet/Solaris_OS_VER/Packages/
For example, if your system is running the Solaris 8 Operating Environment, you
would type the following:
#/usr/sbin/pkgadd -d /cdrom/cdrom0/GigaSwiftEthernet/Solaris_8/Packages/
A menu similar to the following displays:
The following packages are available:
1 SUNWcea
2 SUNWceax
3 SUNWced.u
4 SUNWcedu
5 SUNWcedx.u
6 SUNWcem
7 SUNWvld
8 SUNWvldu
9 SUNWvldx
Sun GigaSwift Ethernet Adapter Driver 32 bit adb Macros
(sparc) 1.0,REV=2001.05.04
Sun GigaSwift Ethernet Adapter Driver 64 bit adb Macros
(sparc) 1.0,REV=2001.05.04
Sun GigaSwift Ethernet Adapter (32-bit Driver)
(sparc.sun4u) 1.0,REV=2001.05.04
Sun GigaSwift Ethernet Adapter Driver Headers
(sparc) 1.0,REV=2001.05.04
Sun GigaSwift Ethernet Adapter (64-bit Driver)
(sparc.sun4u) 1.0,REV=2001.05.04
Sun GigaSwift Ethernet Adapter Driver Man Pages
(sparc) 1.0,REV=2001.05.04
Sun Ethernet Vlan Utility Routines
(sparc) 1.0,REV=2001.05.04
Sun Ethernet Vlan Utility Headers
(sparc) 1.0,REV=2001.05.04
Sun Ethernet Vlan Utility Routines (64-bit)
(sparc) 1.0,REV=2001.05.04
Select package(s) you wish to process (or ’all’ to process
4. Select the packages you want to install:
■ Press Return or type allto accept the default and install all packages.
■ Type the number of all but the optional packages if you prefer not to install them.
See TABLE 2-1 to identify the optional packages.
Chapter 2
Installing the Adapter
11
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ To Install Driver Software for Solaris 2.6
Operating Environments
1. Become superuser.
2. Insert the Sun GigaSwift Ethernet Driver 1.0 CD into a CD-ROM drive that is
connected to your system.
■ If your system is running Sun Enterprise Volume Manager™, it should
automatically mount the CD-ROM to the /cdrom/cdrom0directory.
■ If your system is not running Volume Manager, mount the CD-ROM as follows:
# mkdir /cdrom
# mkdir /cdrom/cdrom0
# mount -F hsfs -o ro /dev/dsk/c0t6d0s2 /cdrom/cdrom0
3. Install the software packages by typing the following at the command line.
# cd /cdrom/cdrom0/GigaSwiftEthernet/Solaris_2.6
# /usr/sbin/pkgadd -d sparc_arch/Packages all
Where sparc_arch is either sparc.sun4uor sparc.sun4u1for Sun Enterprise™
10000 systems.
Note – The sparc.sun4u1contains the Solaris 2.6 packages only for Enterprise
10000 systems.
Verifying Patches
Verify whether your system has the needed patches for your version of the Solaris
operating environment to ensure that you do not need to add patches.
● To verify patches for Solaris 2.6 and 7 operating environments, type the following.
# showrev -p | grep 112327
The patch version should be -07 or greater.
12
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
● To verify patches for Solaris 8 operating environments, type the following.
# showrev -p | grep 111883
The patch version should be -13 or greater.
● To verify patches for Solaris 9 operating environments, type the following.
# showrev -p | grep 112817
The patch version should be -05 or greater.
Chapter 2
Installing the Adapter
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Adapter Without Dynamic
Reconfiguration
▼ To Install the Adapter
Note – The following instructions describe the basic tasks required to install the
adapter. Refer to your system installation or service manual for detailed PCI adapter
installation instructions.
1. Halt and power off your system.
2. Power off all of the peripherals connected to your system.
3. Open the system unit.
4. Attach the adhesive copper strip of the antistatic wrist strap to the metal casing of
the power supply. Wrap the other end twice around your wrist, with the adhesive
side against your skin.
5. Holding the PCI adapter by the edges, unpack it and place it on an antistatic
surface.
6. Using a No. 1 Phillips screwdriver, remove the PCI filler panel from the slot in
which you want to insert the PCI adapter.
Save the filler panel screw for Step 9.
7. Holding the PCI adapter by the edges, align the adapter edge connector with the
PCI slot. Slide the adapter face plate into the small slot at the end of the PCI
opening.
14
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Applying even pressure at both corners of the adapter, push the PCI adapter until
it is firmly seated in the slot.
Caution – Do not use excessive force when installing the adapter into the PCI slot.
You may damage the adapter’s PCI connector. If the adapter does not seat properly
when you apply even pressure, remove the adapter and carefully reinstall it again.
9. Secure the adapter to the PCI slot using the screw you removed in Step 6.
10. Detach the wrist strap and close the system unit.
11. Connect the cables.
■ For the Sun GigaSwift Ethernet MMF PCI Bus card, connect the fiber optic cable
(850nm, SC) to the PCI adapter and to a fiber optic Ethernet network.
FIGURE 2-1 Connecting the Fiber Optic Cable
■ For the Sun GigaSwift Ethernet UTP PCI Bus card, connect a Cat-5 twisted-pair
cable.
Chapter 2
Installing the Adapter
15
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-2 Cat-5 Twisted-Pair Cable
▼ To Verify the Installation
After you have installed the Sun GigaSwift Ethernet adapter, but before you boot
your system, perform the following tasks to verify the installation. Refer to the
Solaris Handbook for Sun Peripherals manual or your Solaris documentation for the
detailed instructions.
Note – Verification is not required if your system supports dynamic reconfiguration
(DR).
1. Power on the system, and when the banner appears, press the Stop-A key
sequence to interrupt the boot process and display the OpenBoot (ok) prompt.
If the card is properly installed and the cables are properly connected to a
compatible network, you will see the following message:
xcvr addr:0x00 - link up 1000 Mbps full duplex
16
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
2. List the network devices on your system.
ok show-nets
Use the show-netscommand to list the system devices. You should see the full
path name of the networkdevices, similar to the Ultra 30 system example below. In
this example, the network@4device is the Sun GigaSwift Ethernet adapter and the
network@1,1is the onboard Ethernet device.
ok show-nets
a) /pci@1f,2000/pci@1/network@4
b) /pci@1f,4000/network@1,1
q) NO SELECTION
Enter Selection, q to quit: q
Note – If you do not see the device listed, check that the adapter is properly seated
and, if necessary, reinstall the adapter.
3. View the device that you installed.
Using the previous example, type:
ok cd /pci@1f,0/pci@1/network@4
Be sure to write down your device path, which in the example is
/pci@1f,0/pci@1/network@4. While your device path may be different, it will be
similar. You will need this information to make changes to the ce.conffile. See
“Setting Parameters Using the ce.confFile” on page 51.
Chapter 2
Installing the Adapter
17
Download from Www.Somanuals.com. All Manuals Search And Download.
4. View the.propertiesfile for a list of device properties.
It might be difficult to tell if the devices on your network are GigaSwift Ethernet
devices or other network interface cards. The.propertiescommand displays the
specific information about the installed adapter.
At the okprompt, use the .propertiescommand to make sure that the device you
just installed is connected to the network. Your output may look different from the
following example:
ok .properties
assigned-addresses
82002010 00000000 01000000 00000000 00200000
82002030 00000000 01200000 00000000 00100000
d-fru-len
d-fru-off
d-fru-dev
s-fru-len
s-fru-off
s-fru-dev
compatible
reg
00 00 00 00
00 00 e8 00
eeprom
00 00 08 00
00 00 e0 00
eeprom
70 63 69 31 30 38 65 2c 61 62 62 61 2e 31 31 00
00002000 00000000 00000000 00000000 00000000
02002010 00000000 00000000 00000000 00200000
02002030 00000000 00000000 00000000 00100000
00 00 00 30
address-bits
max-frame-size
00 00 40 00
network-interface-type ethernet
device_type
name
network
network
local-mac-address
version
08 00 20 aa bb cc
Sun PCI Gigaswift 1000Base-T FCode 2.11 02/09/23
phy-type
mif
board-model
model
501-5525
SUNW,pci-ce
00000000
fcode-rom-offset
66mhz-capable
fast-back-to-back
devsel-speed
class-code
interrupts
00000002
00020000
00000001
00000002
00000003
00000004
00000040
00000040
00000011
0000abba
0000108e
max-latency
min-grant
revision-id
device-id
vendor-id
18
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
The phy-typewill have its value assigned as follows:
Media type
phy-type
Copper
mif
Note – If you are going to set the local-mac-addressproperty, note the
local-mac-addressof your device at this time. See “Setting the local-mac-
addressProperty” on page 19 for more information.
Setting the local-mac-addressProperty
Note – Setting the local-mac-addressproperty is only required if you will be
booting from the network.
The network interface of the Sun GigaSwift Ethernet adapter has been assigned a
unique media access control (MAC) address that represents the 48-bit Ethernet
address for that interface. The OpenBoot firmware reports this MAC address via the
local-mac-addressproperty in the device nodes corresponding to the network
interface.
A system is not obligated to use this assigned MAC address if it has a system-wide
MAC address. In such cases, the system-wide MAC address applies to all network
interfaces on the system.
The device driver, or any other adapter utility, can use the network device’s MAC
address (local-mac-address) while configuring it. In the Solaris operating
environment, you can use the MAC address when booting over the network.
The mac-addressproperty of the network device specifies the network address
(system-wide or local-mac-address) used for booting the system. To start using
the MAC address assigned to the network interface of the Sun GigaSwift Ethernet
adapter, set the NVRAM configuration variable local-mac-address?to true.
ok setenv local-mac-address? true
Chapter 2
Installing the Adapter
19
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ To Set the GigaSwift Ethernet Device Primary Boot Device
Use this procedure only if you want the GigaSwift Ethernet device to be your
primary boot device.
1. List the network devices on your system.
ok show-nets
a) /pci@1f,2000/pci@1/network@4
b) /pci@1f,4000/network@1,1
q) NO SELECTION
Enter Selection, q to quit: q
2. Set the Sun GigaSwift Ethernet device to be your default boot device, type:
ok setenv boot-device /pci@1f,2000/pci@1/network@4
Note that the correct command has a space rather than =between boot-device
and /pci@1f,2000/pci@1/network@4.
Rebooting the System
After verifying the adapter installation, use the boot -rcommand to perform a
reconfiguration boot on your system.
ok boot -r
20
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Adapter With Dynamic
Reconfiguration
If you have a Sun Enterprise system that supports dynamic reconfiguration (DR),
you do not have to reboot your system after installing the adapter.
The process of adding and configuring an adapter with DR involves (1) connecting
the attachment point and (2) configuring its occupant. In most cases, the
cfgadm(1M) command can perform both steps at once.
▼ To Install an Adapter in a Dynamic
Reconfiguration System
1. Verify that the selected board slot is ready for the adapter.
# cfgadm
The states and conditions should be:
Receptacle state—Empty
Occupant state—Unconfigured
Condition—Unknown
Or:
Receptacle state—Disconnected
Occupant state—Unconfigured
Condition—Unknown
Chapter 2
Installing the Adapter
21
Download from Www.Somanuals.com. All Manuals Search And Download.
2. If the status of the slot is not “empty” or “disconnected”, type:
# cfgadm -c disconnect sysctrl#:slot#
where the sysctrl# = 0for the Enterprise 10000 and slot#= the slot available for the
adapter. For example, if you were installing the adapter into slot #3 on an Enterprise
10000, you would type the following:
# cfgadm -c disconnect sysctrl0:3
3. Physically insert the adapter into the slot and look for an acknowledgement on
the console, such as, “name board inserted into slot3.”
After the adapter is inserted, the states and conditions should become:
Receptacle state—Disconnected
Occupant state—Unconfigured
Condition—Unknown
Any other states or conditions should be considered an error.
4. Connect any peripheral cables and interface modules to the adapter.
5. Connect the cables to the card and to an Ethernet network.
6. Configure the adapter with the following command:
# cfgadm -v -c configure sysctrl#:slot#
This command should both connect and configure the receptacle. Verify with the
cfgadmcommand.
The states and conditions for a connected and configured attachment point should
be:
Receptacle state—Connected
Occupant state—Configured
Condition—OK
22
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Now the system is also aware of the usable devices which reside on the adapter and
all devices may be mounted or configured to be used.
If the command fails to connect and configure the adapter and slot (the status should
be shown as “configured” and “ok”), do the connection and configuration as
separate steps:
a. Connect the adapter and slot:
# cfgadm -v -c connect sysctrl#:slot#
The states and conditions for a connected attachment point should be:
Receptacle state—Connected
Occupant state—Unconfigured
Condition—OK
Now the system is aware of the adapter, but not the usable devices which reside
on the adapter. Temperature is monitored and power and cooling affect the
attachment point condition.
b. Configure the adapter and slot:
# cfgadm -v -c configure sysctrl#:slot#
The states and conditions for a configured attachment point should be:
Receptacle state—Connected
Occupant state—Configured
Condition—OK
Now the system is also aware of the usable devices which reside on the adapter and
all devices may be mounted or configured to be used.
7. Reconfigure the devices on the adapter
# drvconfig; devlinks; disks; ports; tapes;
The console should now display a list of devices and their addresses.
Chapter 2
Installing the Adapter
23
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
3
Network Configuration
installed on your system. The chapter contains the following sections:
■ “Configuring the Network Host Files” on page 25
■ “Setting Up a GigaSwift Ethernet Network on a Diskless Client System” on
page 27
■ “Installing the Solaris Operating Environment Over a GigaSwift Ethernet
Network” on page 29
Configuring the Network Host Files
After installing the driver software, you must create a hostname.cenumber file for
the adapter’s Ethernet interface. You must also create both an IP address and a host
name for its Ethernet interface in the /etc/hostsfile.
1. At the command line, use the grepcommand to search the /etc/path_to_inst
file for ceinterfaces.
# grep ce /etc/path_to_inst
"/pci@1f,4000/network@4" 0 "ce"
In the example above, the device instance is from a Sun GigaSwift Ethernet adapter
installed in slot 1. For clarity, the instance number is in bold italics.
Be sure to write down your device path and instance, which in the example is
“/pci@1f,0/pci@1/network@4” 0. While your device path and instance may be
different, it will be similar. You will need this information to make changes to the
ce.conffile. See “Setting Parameters Using the ce.confFile” on page 51.
2. Use the ifconfigcommand to setup the adapter’s ceinterface.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Use the ifconfigcommand to assign an IP address to the network interface. Type
the following at the command line, replacing ip_address with the adapter’s IP
address:
# ifconfig ce0 plumb ip_address up
Refer to the ifconfig(1M) man page and the Solaris documentation for more
information.
■ If you want a set-up that will remain the same after you reboot, create an
/etc/hostname.cenumber file, where number corresponds to the instance
number of the ceinterface you plan to use.
To use the adapter’s ceinterface in the Step 1 example, create an
/etc/hostname.ce0file, where 0is the number of the ceinterface. If the
instance number were 1, the filename would be
/etc/hostname.ce1.
■ Do not create an /etc/hostname.cenumber file for a Sun GigaSwift Ethernet
adapter interface you plan to leave unused.
■ The /etc/hostname.cenumber file must contain the hostname for the
appropriate ceinterface.
■ The host name should have an IP address and should be listed in the
/etc/hostsfile.
■ The host name should be different from any other host name of any other
interface, for example: /etc/hostname.ce0and /etc/hostname.ce1cannot
share the same host name.
The following example shows the /etc/hostname.cenumber file required for a
system called zardozthat has a Sun GigaSwift Ethernet adapter (zardoz-11).
# cat /etc/hostname.hme0
zardoz
# cat /etc/hostname.ce0
zardoz-11
26
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Create an appropriate entry in the /etc/hostsfile for each active ceinterface.
For example:
# cat /etc/hosts
#
# Internet host table
#
127.0.0.1
localhost
129.144.10.57 zardoz
loghost
129.144.11.83 zardoz-11
Setting Up a GigaSwift Ethernet
Network on a Diskless Client System
Before you can boot and operate a diskless client system across a gigabit Ethernet
network, you must first install the GigaSwift Ethernet software packages into the
root directory of the diskless client. You can find the GigaSwift Ethernet software
packages on the Sun GigaSwift Ethernet Driver 1.0 Update 1 CD. Refer to the Solaris
Advanced Installation Guide and the System Administration Guide for more information
about installing and administering diskless client systems.
Note – The Solaris 8 operating environment does not support diskless clients.
▼ To Set Up a GigaSwift Ethernet Port on a
Diskless Client
1. Locate the root directory of the diskless client on the host server.
The root directory of diskless client system is commonly installed in the host
server’s /export/root/client_name directory, where client_name is the diskless
client’s host name. In this procedure, the root directory will be:
/export/root/client_name
Chapter 3
Network Configuration
27
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Insert the Sun GigaSwift Ethernet Driver 1.0 Update 1 CD into the server’s CD-ROM
drive.
The CD should automatically mount to the /cdrom/cdrom0directory. If the CD did
not get mounted to this directory, refer to “Installing the Driver Software” on page 9
for mounting instructions.
3. Use the pkgadd -Rcommand to install the three GigaSwift Ethernet software
packages to the diskless client’s root directory on the server.
You will need to install the SUNWced.u, SUNWcedm, and SUNWcedusoftware
packages to the client’s root directory.
# cd /cdrom/cdrom0/GigaSwiftEthernet/Packages
# pkgadd -R /export/root/client_name -d . SUNWced.u SUNWcem SUNWcedu
# cd /
4. Eject the Sun GigaSwift Ethernet Driver 1.0 Update 1 CD from the CD-ROM drive.
5. Create a hostname.cenumber file in the diskless client’s root directory.
file for the GigaSwift Ethernet interface. See “Configuring the Network Host Files”
on page 25 for instructions.
6. Edit the hostsin the diskless client’s root directory.
You will need to edit the /export/root/client_name/etc/hostsfile to include the
IP address of the GigaSwift Ethernet interface. See “Configuring the Network Host
Files” on page 25 for instructions.
7. Be sure to set the MAC address on the server side and rebuild the device tree if
you want to boot from the GigaSwift Ethernet port.
8. To boot the diskless client from the GigaSwift Ethernet port, type the following
boot command:
ok boot path-to-device:link-param, -v
28
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Solaris Operating
Environment Over a GigaSwift Ethernet
Network
The Solaris Advanced Installation Guide describes the full procedure for installing the
Solaris operating environment over the network. The procedure below assumes that
you have created an install server, which contains the image of the Solaris CD, and
that you have set up the client system to be installed over the network.
Before you can install the Solaris operating environment on a client system with a
GigaSwift Ethernet adapter, you must first add the GigaSwift Ethernet software
packages to the install server. These software packages are on Sun GigaSwift Ethernet
Driver 1.0 Update 1 CD.
Note – Refer to the Solaris Advanced Installation Guide for more information about
installing the Solaris operating environment over the network.
▼ To Install the Solaris Environment Over a
GigaSwift Ethernet Network
1. Prepare the install server and client system to install the Solaris operating
environment over the network.
The Solaris Advanced Installation Guide describes how to create the install server and
set up the client systems.
Note – If you want to install the client system over a network that is not part of the
same subnet, you must also create a boot server. The Solaris Advanced Installation
Guide describes how to create a boot server.
Chapter 3
Network Configuration
29
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Find the root directory of the client system.
The client system’s root directory can be found in the install server’s
/etc/bootparamsfile. Use the grepcommand to search this file for the root
directory.
# grep client_name /etc/bootparams
client_name root=server_name:/netinstall/Solaris_2.7/Tools/Boot
install=server_name:/netinstall boottype=:in rootopts=:rsize=32768
In the example above, the root directory for the Solaris 7 client is /netinstall. In
Step 4, you would replace root_directory with /netinstall.
Note – If the root directory is not found in the /etc/bootparamsfile, refer to the
3. Insert the Sun GigaSwift Ethernet Driver 1.0 Update 1 CD into the install server’s CD-
ROM drive.
The CD should automatically mount to the /cdrom/cdrom0directory. If the CD did
not get mounted to this directory, refer to “Installing the Driver Software” on page 9
for mounting instructions.
4. On the install server, install the GigaSwift Ethernet software to the client’s root
directory, as determined in Step 2.
Replace root_directory with the location of the client’s root directory.
# cd /cdrom/cdrom0/GigaSwiftEthernet/Packages
# ls SUNWce*
SUNWcea SUNWceax SUNWced SUNWcedu SUNWcem
# pkgadd -R root_directory/Solaris_2.7/Tools/Boot -d . SUNWced SUNWcem SUNWcedu
# cd /
Note – The directory paths for these files might change in future Solaris releases. If
the commands above do not work correctly, refer to the documentation that shipped
with your version of the Solaris operating environment.
5. Eject the Sun GigaSwift Ethernet Driver 1.0 Update 1 CD from the CD-ROM drive.
Note – Perform the following steps on the client system.
30
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Shut down and halt the client system.
Use the shutdowncommand to display the OpenBoot (ok) prompt.
# shutdown -i0 -g0 -y
. . .
(shutdowncommand messages omitted)
. . .
ok
7. At the okprompt, use the show-netscommand to find the device path of the
GigaSwift Ethernet device.
The show-netscommand lists the system devices. You should see the full path
name of the network device, similar to the example below. In this example, the
network@4device is the Sun GigaSwift Ethernet adapter.
ok show-nets
a) /pci@1f,2000/pci@1/network@4
b) /pci@1f,4000/network@1,1
q) NO SELECTION
Enter Selection, q to quit: q
8. At the okprompt, boot the client system using the full device path of the Gigabit
Ethernet device.
Following are several examples, which show the different options available:
■ Booting in Auto-Negotiated mode:
ok boot:link-param, -v
■ Booting in Auto-Negotiated verbose mode at 1000 Mbps half duplex:
ok boot /pci@1f,4000/network@4:speed=1000,duplex=half,link-clock=auto
Note – link-clock must be set to auto.
For this configuration the highest capability is limited to 1000 Mbps half duplex
and the lowest is 10 Mbps half duplex, hence the link will be established within
this range of capabilities, depending on the configuration of the link partner.
Chapter 3
Network Configuration
31
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Booting in non-Auto-Negotiated verbose mode at 100 Mbps full duplex:
ok boot /pci@1f,4000/network@4:speed=100,duplex=full, -v
■ Booting in non-Auto-Negotiated verbose mode at 1000 Mbps half duplex link-
clock master:
ok boot /pci@1f,4000/network@4:speed=1000,duplex=half,link-clock=master
Note – For link to be successfully established the link partner must be configured to
1000 Mbps half duplex link-clockslave.
Refer to the Solaris Advanced Installation Guide for more information about installing
the Solaris operating environment over the network.
10. After installing the Solaris operating environment, install the Sun GigaSwift
Ethernet software on the client system.
The software installed in Step 4 was required to boot the client system over the
GigaSwift Ethernet interface. You now need to install the software in order for the
operating system to use the client’s GigaSwift Ethernet interfaces in normal
operation.
Before installing the Sun GigaSwift Ethernet software, make sure that the client
system does not already have the software installed. Use the pkginfocommand to
see if the Sun GigaSwift Ethernet software packages are installed on the client
system.
# pkginfo | grep SUNWce
system SUNWced Sun Gigabit Ethernet Adapter Driver
system SUNWcedu Sun Gigabit Ethernet Adapter Driver Headers
■ If the software is installed (as shown in the example above), skip to Step 11.
■ If the software is not installed, install the software from Solaris Supplement CD.
Refer to “Installing the Driver Software” on page 9 for instructions on installing
the required software packages.
32
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
11. Confirm that the network host files have been configured correctly during the
Solaris installation.
Although the Solaris software installation creates the client’s network configuration
files, you may need to edit these files to match your specific networking
environment. See “Configuring the Network Host Files” on page 25 for more
information about editing these files.
Booting Over the GigaSwift Ethernet
Network
The Sun GigaSwift Ethernet adapter can be linked up either with Auto-Negotiation
enabled or disabled. When link-up is attempted with Auto-Negotiation enabled (the
default), the link parameter capabilities (such as speed in megabits/ second, duplex
and link-clock mastership only for 1000 Mbps) are automatically negotiated between
the device and its link partner. Attempting to link-up with Auto-Negotiation
disabled requires knowledge of the current capabilities at which both the device and
its link partner are configured.
The structure of the boot net command line that includes device parameters is as
follows:
ok boot device-path:speed=s,duplex=d,link-clock=c,promiscuous,
where,
s = 1000, 100, 10, auto
d = half, full, auto
c = master, slave, auto
Negotiated and non-Auto-Negotiated modes of operation. (To establish the link
successfully so that traffic is transfered without collisions caused by duplex
mismatch between the local and remote devices both the local and remote link
capabilities must be matched.)
TABLE 3-1 depicts the device link parameters you can specify on the boot net
command line to establish a link between the local and remote device. TABLE 3-2
shows the speed, duplex and link-clockcapabilities at which a link-up will be
attempted:
Chapter 3
Network Configuration
33
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 3-1
Device Link Parameters
Device Parameters
Device Link Capability
speed
1000
1000
1000
1000
1000
1000
1000
100
duplex
full
link-clock
autoneg
1000fdx
1000hdx
100fdx
100hdx
10fdx
0
10hdx
master/ slave
master/ slave
auto
0
0
1
1
1
1
1
0
1
1
0
1
1
1
0
0
1
1
0
0
1
1
1
1
1
1
1
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
1
0
1
1
1
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
1
1
1
1
1
1
0
1
1
0
0
0
0
1
0
1
1
1
0
0
1
1
1
1
1
0
0
1
1
1
0
1
1
1
0
1
1
1
half
full
0
1
half
auto
auto
1
1
1
auto
N/ A
N/ A
N/ A
1
full
half
auto
0
100
1
100
1
100
1
10
full
half
auto
N/ A
N/ A
N/ A
0
0
10
0
10
0
10
0
auto
auto
auto
auto
full
half
auto
0
1
1
1
auto
auto
1
TABLE 3-2 link-clockCapabilities for Link Up
link-clock
slave
master-cfg-enable
master-cfg-value
Description
1
1
0
0
1
0
link clock slave
master
auto
link clock master
default link clock auto
34
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Following are examples showing the usage of the boot net command line with
device parameters specified:
To attempt to force the link-up while advertising 100 Mbps full duplex capability to
the link partner:
# boot net:speed=100,duplex=full,
To attempt to force link-up while advertising 1000 Mbps full duplex link-clock
master capibility to the link partner:
# boot net:speed=1000,duplex=full,link-clock=master,
Note – The link partner must be configured as link-clock slave.
To attempt to Auto-Negotiate the link while advertising 1000 Mbps full and half
duplex and link-clock auto capability to the link partner:
# boot net:speed=1000,duplex=auto,link-clock=auto,
Note – Link partner must Auto-Negotiate in order to link-up at 1000 Mbps.
Chapter 3
Network Configuration
35
Download from Www.Somanuals.com. All Manuals Search And Download.
36
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
4
Configuring Driver Parameters
This chapter describes how to configure the driver parameters used by the Sun
GigaSwift Ethernet adapter. This chapter contains the following sections:
■ “GigaSwift Ethernet Device Driver Parameters” on page 37
■ “Setting ceDriver Parameters” on page 47
■ “Usability Enhancements to the Driver” on page 53
■ “GigaSwift Ethernet Driver Operating Statistics” on page 54
GigaSwift Ethernet Device Driver
Parameters
The cedevice driver controls the GigaSwift Ethernet devices. The cedriver is
attached to the UNIX pciname property pci108e,abbafor the Sun GigaSwift
Ethernet adapter (108eis the vendor ID and abbais the PCI device ID).
You can manually configure the cedevice driver parameters to customize each Sun
overview of the capabilities of the GigaSwift Ethernet device used in the adapter,
lists the available cedevice driver parameters, and describes how to configure these
parameters.
The Sun GigaSwift Ethernet UTP PCI adapter is capable of all the operating speeds
and modes listed in “Setting the Autonegotiation Mode” on page 50. The ce device
performs autonegotiation with the remote end of the link (link partner) to select a
common mode of operation. The ce device also supports a forced mode of operation.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Note – The syntax for the Sun GigaSwift Ethernet driver parameters has changed.
The syntax for parameters formerly included an underscore, for example,
adv_autoneg_cap. The current syntax uses a dash instead, for example,
adv-autoneg-cap. During the transition phase, either format is acceptable.
However, be sure to check the Platform Notes: Sun GigaSwift Ethernet Device Driver in
your version of the Solaris operating environment.
Driver Parameter Values and Definitions
TABLE 4-1 describes the parameters and settings for the cedevice driver.
TABLE 4-1 ceDriver Parameter, Status, and Descriptions
Parameter
Status
Description
instance
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Device instance
adv-autoneg-cap
adv-1000fdx-cap
adv-1000hdx-cap
adv-100T4-cap
adv-100fdx-cap
adv-100hdx-cap
adv-10fdx-cap
adv-10hdx-cap
adv-asmpause-cap
adv-pause-cap
master-cfg-enable
master-cfg-value
use-int-xcvr
enable-ipg0
ipg0
Operational mode parameter
Operational mode parameter
Operational mode parameter
Operational mode parameter
Operational mode parameter
Operational mode parameter
Operational mode parameter
Operational mode parameter
Flow control parameter
Flow control parameter
Gigabit link clock mastership controls
Gigabit link clock mastership controls
Enable additional delay before transmitting a packet
Additional delay before transmitting a packet
Interpacket Gap parameter
ipg1
ipg2
Interpacket Gap parameter
rx-intr-pkts
rx-intr-time
Receive interrupt blanking values
Receive interrupt blanking values
38
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 4-1 ceDriver Parameter, Status, and Descriptions (Continued)
Parameter
Status
Description
red-dv4to6k
red-dv6to8k
red-dv8to10k
red-dv10to12k
tx-dma-weight
rx-dma-weight
infinite-burst
disable-64bit
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Read and write
Random early detection and packet drop vectors
Random early detection and packet drop vectors
Random early detection and packet drop vectors
Random early detection and packet drop vectors
PCI Interface parameter
PCI Interface parameter
PCI Interface parameter
PCI Interface parameter
Operational Mode Parameters
The following parameters determine the transmit and receive speed and duplex.
TABLE 4-2 describes the operational mode parameters and their default values.
TABLE 4-2
Parameter
Operational Mode Parameters
Description
adv-autoneg-cap
adv-1000fdx-cap
adv-1000hdx-cap
adv-100T4-cap
Local interface capability advertised by the hardware
0 = Forced mode
1 = Autonegotiation (default)
Local interface capability advertised by the hardware
0 = Not 1000 Mbit/ sec full-duplex capable
1 = 1000 Mbit/ sec full-duplex capable (default)
Local interface capability advertised by the hardware
0 = Not 1000 Mbit/ sec half-duplex capable
1 = 1000 Mbit/ sec half-duplex capable (default)
Local interface capability advertised by the hardware
0 = Not 100T4 capable (default)
1 = 100T4 capable
adv-100fdx-cap
Local interface capability advertised by the hardware
0 = Not 100 Mbit/ sec full-duplex capable
1 = 100 Mbit/ sec full-duplex capable (default)
Chapter 4
Configuring Driver Parameters
39
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 4-2
Parameter
Operational Mode Parameters (Continued)
Description
adv-100hdx-cap
adv-10fdx-cap
adv-10hdx-cap
Local interface capability advertised by the hardware
0 = Not 100 Mbit/ sec half-duplex capable
1 = 100 Mbit/ sec half-duplex capable (default)
Local interface capability advertised by the hardware
0 = Not 10 Mbit/ sec full-duplex capable
1 = 10 Mbit/ sec full-duplex capable (default)
Local interface capability advertised by the hardware
0 = Not 10 Mbit/ sec half-duplex capable
1 = 10 Mbit/ sec half-duplex capable (default)
Note – If a parameter ’s initial setting is 0, it cannot be changed. If you try to change
it, it will revert back to 0.
If all these parameters are set to 1, autonegotiation will use the highest speed
possible. If all these parameters are set to 0, you will receive the following error
message:
NOTICE: Last setting will leave ce1 with no link capabilities.
WARNING: ce1: Restoring previous setting.
Flow Control Parameters
The cedevice is capable of sourcing (transmitting) and terminating (receiving)
pause frames conforming to the IEEE 802.3x Frame Based Link Level Flow Control
Protocol. In response to received flow control frames, the cedevice can slow down
its transmit rate. On the other hand, the cedevice is capable of sourcing flow control
frames, requesting the link partner to slow down, provided that the link partner
supports this feature. By default, the driver advertises both transmit and receive
pause capability during autonegotiation.
40
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 4-3 provides flow control keywords and describes their function.
TABLE 4-3
Keyword
Read-Write Flow Control Keyword Descriptions
Description
adv-asmpause-cap
The adapter supports asymmetric pause, which means it
can pause only in one direction.
0=Off (default)
1=On
adv-pause-cap
This parameter has two meanings depending on the
value of adv-asmpause-cap. (Default=0)
If adv-asmpause-cap= 1 while adv-pause-cap= 1
pauses are received.
If adv-asmpause-cap= 1 while adv-pause-cap= 0
pauses are transmitted.
If adv-asmpause-cap= 0 while adv-pause-cap= 1
pauses are sent and received.
If adv-asmpause-cap= 0 then adv-pause-cap
determines whether Pause capability is on or off.
Chapter 4
Configuring Driver Parameters
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Gigabit Link Clock Mastership Controls
The concept of link clock mastership introduced with one gigabit twisted-pair
technology. This concept requires one side of the link to be the master that provides
the link clock and the other to be the slave that uses the link clock. Once this
relationship is established the link is up, and data can be communicated. Two
Physical layer parameters control whether your side is the master or the slave or
whether mastership is negotiated with the link partner. Those parameters are as
follows.
TABLE 4-4
Parameter
Forced Mode Parameter
Description
master-cfg-enable
master-cfg-value
Determines whether or not during the auto-negotiation process
the link clock mastership is setup automatically.
If the master-cfg-enableparameter is set then the mastership
is not setup automatically but is dependant on the value of
master-cfg-value. If the master-cfg-valueis set then the
physical layer expects the local device to be the link master. If it is
not set then it expects the link partner to be the master.
If Auto-negotiation is not enabled then the value of
master-cfg-enableis ignored and the value of
master-cfg-valueis key to the link clock mastership. If the
master-cfg-valueis set then the physical layer expects the
local device to be the link master. If it’s not set then it expects the
link partner to the master.
Caution – Do not adjust the link clock mastership parameters unless you clearly
understand the settings of the link partner. Incorrect link clock mastership
configuration results in link up failure.
Interpacket Gap Parameters
The cedevice supports a programmable mode called enable-ipg0.
When a driver receives a packet with enable-ipg0set (the default), it adds an
additional time delay before transmitting the packet. This delay, set by the ipg0
parameter, is in addition to the delay set by the ipg1and ipg2parameters. The
additional ipg0delay helps to reduce collisions.
42
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
If enable-ipg0is disabled, the value of ipg0is ignored and no additional delay is
other systems keep sending a large number of back-to-back packets. Systems that
have enable-ipg0set might not have enough time on the network.
You can add the additional delay by setting the ipg0parameter from 0 to 255, which
is the media byte time delay.
TABLE 4-5 defines the enable-ipg0and ipg0parameters.
TABLE 4-5
Parameters Defining enable-ipg0and ipg0
Parameter
Values
Description
enable-ipg0
0
1
enable-ipg0reset
enable-ipg0set (Default=8)
ipg0
0 to 255
The additional time delay (or gap) before
transmitting a packet (after receiving the
packet) (Default=8)
The cedevice supports the programmable Interpacket Gap (IPG) parameters ipg1
and ipg2. The total IPG is the sum of ipg1and ipg2. The total IPG is 0.096
microseconds for the link speed of 1000 Mbps.
TABLE 4-6 lists the default values and allowable values for the IPG parameters.
TABLE 4-6
Parameter
Read-Write Interpacket Gap Parameter Values and Descriptions
Values
Description
(Byte-time)
ipg1
ipg2
0 to 255
0 to 255
Interpacket gap 1 (Default = 8)
Interpacket gap 2 (Default = 4)
By default, the driver sets ipg1to 8-byte time and ipg2to 4-byte time, which are
the standard values. (Byte time is the time it takes to transmit one byte on the link,
with a link speed of 1000 Mbps.)
If your network has systems that use longer IPG (the sum of ipg1and ipg2), and if
those machines seem to be slow in accessing the network, increase the values of
ipg1and ipg2to match the longer IPGs of other machines.
Chapter 4
Configuring Driver Parameters
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Interrupt Parameters
TABLE 4-7 describes the receive interrupt blanking values.
TABLE 4-7
RX Blanking Register for Alias Read
Field Name
Values
Description
rx-intr-pkts
0 to 511
Interrupt after this number of packets have arrived since
the last packet was serviced. A value of zero indicates no
packet blanking. (Default=8)
rx-intr-time
0 to 524287
Interrupt after 4.5 microseconds ticks have elapsed since
the last packet was serviced. A value of zero indicates no
time blanking. (Default=3)
44
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Random Early Drop Parameters
TABLE 4-8 describes the RX random early detection 8-bit vectors, which allows you to
enable random early drop (RED) thresholds. When received packets reach the RED
range packets are dropped according to the preset probability. The probability
should increase when the FIFO level increases. Control packets are never dropped
and are not counted in the statistics.
TABLE 4-8
RX Random Early Detecting 8-Bit Vectors
Field Name
Values
Description
red-dv4to6k
0 to 255
Random early detection and packet drop vectors for
when FIFO threshold is greater than 4096 bytes and less
than 6,144 bytes. Probability of drop can be
programmed on a 12.5 percent granularity. For
example, if bit 0 is set the first packet out of every eight
will be dropped in this region. (Default=0)
red-dv6to8k
red-dv8to10k
0 to 255
Random early detection and packet drop vectors for
when FIFO threshold is greater than 6,144 bytes and
less than 8,192 bytes. Probability of drop can be
programmed on a 12.5 percent granularity. For
example, if bit 0 is set the first packet out of every eight
will be dropped in this region. (Default=0)
0 to 255
Random early detection and packet drop vectors for
when FIFO threshold is greater than 8,192 bytes and
less than 10,240 bytes. Probability of drop can be
programmed on a 12.5 percent granularity. For
example, if bit 1 and 6 are set the second and seventh
packets out of every eight will be dropped in this
region. (Default=0)
red-dv10to12k
0 to 255
Random early detection and packet drop vectors for
when FIFO threshold is greater than 10,240 bytes and
less than 12,288 bytes. Probability of drop can be
programmed on a 12.5 percent granularity. If bit 2, 4
and 6 are set then the third, fifth and seventh packets
out of every eight will be dropped in this region.
(Default=0)
Chapter 4
Configuring Driver Parameters
45
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Bus Interface Parameters
These parameters allow you to modify PCI interface features to gain better PCI
performance for a given application.
TABLE 4-9
Parameter
PCI Bus Interface Parameters
Description
tx-dma-weight
Determine the multiplication factor for granting credit to the TX
side during a weighted round robin arbitration. Values are 0 to 3.
(Default=0) Zero means no extra weighting. The other values
are power of 2 extra weighting, on that traffic. For example
of tx-dma-weight = 0 and rx-dma-weight = 3 then as long as
RX traffic is continuously arriving its priority will be 8 times
greater than TX to access the PCI
rx-dma-weight
infinite-burst
Determine the multiplication factor for granting credit to the RX
side during a weighted round robin arbitration. Values are 0 to 3.
(Default=0)
Allows the infinite burst capability to be utilized. When this is in
effect and the system supports infinite burst, the adapter will not
free the bus until complete packets are transferred across the bus.
Values are 0 or 1. (Default=0)
disable-64bit
Switches off 64 bit capability of the adapter. In some cases, it is
useful to switch off this feature.
Values are 0 or 1. (Default=0, which enables 64 bit capability)
46
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting ceDriver Parameters
You can set the cedevice driver parameters in two ways:
■ Using the nddutility
■ Using the ce.conffile
If you use the nddutility, the parameters are valid only until you reboot the system.
This method is good for testing parameter settings.
To set parameters so they remain in effect after you reboot the system, create a
/platform/sun4u/kernel/drv/ce.conffile and add parameter values to this
file when you need to set a particular parameter for a device in the system.
Setting Parameters Using the nddUtility
Use the nddutility to configure parameters that are valid until you reboot the
system. The nddutility supports any networking driver, which implements the Data
Link Provider Interface (DLPI).
The following sections describe how you can use the cedriver and the nddutility to
modify (with the -setoption) or display (without the -setoption) the parameters
for each cedevice.
Chapter 4
Configuring Driver Parameters
47
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ To Specify Device Instances for the nddUtility
Before you use the nddutility to get or set a parameter for a cedevice, you must
specify the device instance for the utility.
1. Check the /etc/path_to_instfile to identify the instance associated with a
particular device.
# grep ce /etc/path_to_inst
"/pci@1f,2000/pci@1/network@0" 2 "ce"
"/pci@1f,2000/pci@2/network@0" 1 "ce"
"/pci@1f,2000/pci@4/network@0" 0 "ce"
In the example above, the three GigaSwift Ethernet instances are from the installed
adapters. The instance numbers are in bold italics for clarity.
2. Use the instance number to select the device.
# ndd -set /dev/ce instance instance#
The device remains selected until you change the selection.
Noninteractive and Interactive Modes
You can use the nddutility in two modes:
■ Noninteractive
■ Interactive
In noninteractive mode, you invoke the utility to execute a specific command. Once
the command is executed, you exit the utility. In interactive mode, you can use the
utility to get or set more than one parameter value. (Refer to the ndd(1M) man page
for more information.)
48
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the nddUtility in Noninteractive Mode
This section describes how to modify and display parameter values.
● To modify a parameter value, use the -setoption.
If you invoke the nddutility with the -setoption, the utility passes value, which
must be specified, down to the named /dev/cedriver instance, and assigns it to the
parameter:
# ndd -set /dev/ce parameter value
When you change any adv parameter, a message similar to the following appears:
xcvr addr: 0x00 - link up 1000 Mbps full duplex
● To display the value of a parameter, specify the parameter name and omit the
value.
When you omit the -setoption, a query operation is assumed and the utility
queries the named driver instance, retrieves the value associated with the specified
parameter, and prints it:
# ndd /dev/ce parameter
Using the nddUtility in Interactive Mode
● To modify a parameter value in interactive mode, specify ndd /dev/ce, as shown
below.
The nddutility then prompts you for the name of the parameter:
# ndd /dev/ce
name to get/set? (Enter the parameter name or ? to view all
parameters)
After typing the parameter name, the nddutility prompts you for the parameter
value (see TABLE 4-1 through TABLE 4-11).
Chapter 4
Configuring Driver Parameters
49
Download from Www.Somanuals.com. All Manuals Search And Download.
● To list all the parameters supported by the cedriver, type ndd /dev/ce.
(See TABLE 4-1 through TABLE 4-11 for parameter descriptions.)
# ndd /dev/ce
name to get/set ? ?
?
(read only)
instance
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
(read and write)
adv_autoneg_cap
adv_1000fdx_cap
adv_1000hdx_cap
adv_100T4_cap
adv_100fdx_cap
adv_100hdx_cap
adv_10fdx_cap
adv_10hdx_cap
adv_asmpause_cap
adv_pause_cap
master_cfg_enable
master_cfg_value
use_int_xcvr
enable_ipg0
ipg0
ipg1
ipg2
rx_intr_pkts
rx_intr_time
red_dv4to6k
red_dv6to8k
red_dv8to10k
red_dv10to12k
tx_dma_weight
rx_dma_weight
infinite_burst
disable_64bit
name to get/set ?
#
Setting the Autonegotiation Mode
By default, autonegotiation is set to on. This means that the adapter communicates
with its link partner to determine a compatible network speed, duplex mode, and
flow control capability.
50
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ To Disable Autonegotiation Mode
If your network equipment does not support autonegotiation, or if you want to
specify your network speed, you can set autonegotiation to offon the cedevice.
Note – Disabling autonegotiation mode can cause collisions.
1. Set the following driver parameters to the values that are described in the
documentation that shipped with your link partner (for example, a switch):
■ adv-1000fdx-cap
■ adv-1000hdx-cap
■ adv-100hdx-cap
■ adv-10fdx-cap
■ adv-10hdx-cap
■ adv-asmpause-cap
■ adv-pause-cap
See TABLE 4-2 for the descriptions and possible values of these parameters.
2. Set the adv-autoneg-capparameter to 0.
# ndd -set /dev/ce adv-autoneg-cap 0
When you change any nddlink parameter, a message similar to the following
appears:
xcvr addr:0x00 - link up 100 Mbps full duplex
Specify the driver parameter properties on a per-device basis by creating a ce.conf
file in the /platform/sun4u/kernel/drvdirectory. Use a ce.conffile when you
need to set a particular parameter for a device in the system. The parameters you set
are read and write parameters that are listed in “Driver Parameter Values and
Definitions” on page 38.
Note – Configuring the parameters by putting nddcommands in rcX.dscripts is
not supported.
Chapter 4
Configuring Driver Parameters
51
Download from Www.Somanuals.com. All Manuals Search And Download.
The man pages for prtconf(1M) and driver.conf(4) include additional details.
The next procedure shows an example of setting parameters in a ce.conffile.
▼ To Set Driver Parameters Using a ce.confFile
1. Obtain the hardware path names for the cedevices in the device tree.
a. Check the /etc/driver_aliasesfile to identify the name associated with a
particular device:
# grep ce /etc/driver_aliases
ce "pci108e,abba"
b. Locate the path names and the associated instance numbers are in the
/etc/path_to_instfile.
# grep ce /etc/path_to_inst
"/pci@9,700000/network@2" 0 "ce"
"/pci@8,700000/pci@5/network@0" 3 "ce"
"/pci@8,700000/pci@5/network@1" 4 "ce"
■ In the previous example:
■
■
■
The first part within the double quotes specifies the hardware node name in
the device tree.
The number not enclosed in quotes is the instance number (shown in bold
italics).
The last part in double quotes is the driver name.
■ In the device path name, the last component after the last /character and before
the @character is the device name.
■ The path name before the last component is the parent name.
■ The number after the final @character within quotes is referred to as unit-address.
To identify a PCI device unambiguously in the ce.conffile, use the name, parent
name, and the unit-address for the device. Refer to the pci(4) man page for more
information about the PCI device specification.
In the first line in the previous example:
■ parent= “pci@9”
■ unit-address= “2”
In the second line in the previous example:
■ parent= “pci@5”
52
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
■ unit-address= “0”
In the third line in the previous example:
■ parent= “pci@5”
■ unit-address= “1”
2. Set the parameters for the above devices in the
/platform/sun4u/kernel/drv/ce.conffile.
In the following example, the adv_autoneg_capand adv_1000fdx_cap
parameters are set for all Sun GigaSwift Ethernet devices. (See the
driver.conf(4)man page for more information.)
adv-autoneg-cap=0 adv-1000fdx-cap=0;
In the following example, the adv-autoneg-capand adv-1000fdx-cap
parameters are set for a single instance of the Sun GigaSwift Ethernet device.
name="pci108e,abba" parent="pci@9,600000" unit-address="2"
adv-autoneg-cap=0 adv-100hdx-cap=0 adv-100fdx-cap=1 adv-1000fdx-cap=0 adv-
10hdx-cap=0 adv-10fdx-cap=0 adv-1000hdx-cap=0 adv-100T4-cap=0;
Note – The difference between setting parameters for all Sun GigaSwift Ethernet
devices and setting parameters for a single instance of the device depends on
whether you include the name=, parent=, and unit-address=. If you omit these
definitions, the settings become global to all Sun GigaSwift Ethernet instances.
3. Save the ce.conffile.
Usability Enhancements to the Driver
In older Ethernet device drivers, determining the link status for a driver required a
two-step process:
■ First, you had to set the instance:
# ndd -set /dev/hme instance 2
Chapter 4
Configuring Driver Parameters
53
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Then you had to get the link status:
# ndd -get /dev/hme link-status
1
Starting with the Sun GigaSwift Ethernet adapter in the Solarlis 9 operating
environment this method of determining the link status is discouraged, and in some
cases, it is removed completely as a driver feature.
The new improved approach moves all read-only parameters from the nddoptions
into kstat. This simplifies getting link status information by allowing you to do it
with one simple command.
● To get the link status of a driver, type the following command:
# kstat ce:n | grep link_up
link_up
0
where n=instance.
For more information about the kstatcommand, refer the kstatman page
GigaSwift Ethernet Driver Operating
Statistics
These statistics are part of the statistics presented by the netstat -kcommand.
54
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 4-10 describes the read-only Media Independent Interface (MII) capabilities.
These parameters define the capabilities of the hardware. The Gigabit Media
Independent Interface (GMII) supports all of the following capabilities.
TABLE 4-10 Read-Only ceDevice Capabilities
Parameter
Description (Local interface Capabilities)
cap_autoneg
0 = Not capable of autonegotiation
1 = Autonegotiation capable
cap_1000fdx
cap_1000hdx
cap_100fdx
cap_100hdx
cap_10fdx
Local interface full-duplex capability
0 = Not 1000 Mbit/ sec full-duplex capable
1 = 1000 Mbit/ sec full-duplex capable
Local interface half-duplex capability
0 = Not 1000 Mbit/ sec half-duplex capable
1 = 1000 Mbit/ sec half-duplex capable
Local interface full-duplex capability
0 = Not 100 Mbit/ sec full-duplex capable
1 = 100 Mbit/ sec full-duplex capable
Local interface half-duplex capability
0 = Not 100 Mbit/ sec half-duplex capable
1 = 100 Mbit/ sec half-duplex capable
Local interface full-duplex capability
0 = Not 10 Mbit/ sec full-duplex capable
1 = 10 Mbit/ sec full-duplex capable
cap_10hdx
Local interface half-duplex capability
0 = Not 10 Mbit/ sec half-duplex capable
1 = 10 Mbit/ sec half-duplex capable
cap_asm_pause
cap_pause
Local interface flow control capability
0 = Not asymmetric pause capable
1 = Asymmetric pause (from the local device) capable
Local interface flow control capability
0 = Not Symmetric pause capable
1 = Symmetric pause capable
Chapter 4
Configuring Driver Parameters
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Reporting the Link Partner Capabilities
TABLE 4-11 describes the read-only link partner capabilities.
TABLE 4-11 Read-Only Link Partner Capabilities
Parameter
Description
lp_cap_autoneg
0 = No autonegotiation
1 = Autonegotiation
lp_cap_1000fdx
lp_cap_1000hdx
lp_cap_100fdx
lp_cap_100hdx
lp_cap_10fdx
0 = No 1000 Mbit/ sec full-duplex transmission
1 = 1000 Mbit/ sec full-duplex
0 = No 1000 Mbit/ sec half-duplex transmission
1 = 1000 Mbit/ sec half-duplex
0 = No 100 Mbit/ sec full-duplex transmission
1 = 100 Mbit/ sec full-duplex
0 = No 100 Mbit/ sec half-duplex transmission
1 = 1000 Mbit/ sec half-duplex
0 = No 10 Mbit/ sec full-duplex transmission
1 = 10 Mbit/ sec full-duplex
lp_cap_10hdx
0 = No 10 Mbit/ sec half-duplex transmission
1 = 10 Mbit/ sec half-duplex
lp_cap_asm_pause
lp_cap_pause
1 = Asymmetric pause towards link partner capability
0 = Not symmetric pause capable
1 = Symmetric pause capable
If the link partner is not capable of autonegotiation (when lp_cap_autonegis 0),
the remaining information described in TABLE 4-11 is not relevant and the parameter
value = 0.
If the link partner is capable of autonegotiation (when lp_cap_autonegis 1), then
the speed and mode information is displayed when you use autonegotiation and the
link partner capabilities.
56
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 4-12 describes the netstat -k transmit and receive parameters:
TABLE 4-12 Transmit and Receive Parameters
Parameter
Description
Number of Physical layer re-initializations every time you change
link parameters using NDD this increments.
xcvr_inits
rev_id
Revision ID of the GigaSwift Ethernet device useful for recognition
of device being used in the field.
xcvr_addr
xcvr_id
GMII/ MII Physical layer device address for management interface.
GMII/ MII Physical layer device Identification Decimal copy of MII
registers 2 and 3.
lb_mode
Copy of the Loopback mode the device is in, if any.
qos_mode
When zero, the TX queues operate in a simple round robin
queueing scheme, based on TCP/ UDP destination port number. If
set the TX queues operate in a scheme designed to provide VLAN
priorities.
tx_starts
Number of times that the driver attempted to transmit a packet.
tx_dma_bind_fail Number of times a page table entry was not available to allow the
driver to map the kernel memory to device accessible memory for
transmission.
tx_queue0
tx_queue1
tx_queue2
tx_queue3
Number of packets queued for transmission on the first hardware
transmit queue.
Number of packets queued for transmission on the second
hardware transmit queue.
Number of packets queued for Transmission on the third hardware
transmit queue.
Number of packets queued for Transmission on the fourth
hardware transmit queue.
tx_max_pend
rx_hdr_pkts
rx_mtu_pkts
Maximum number of transmits pending on any of the four queues.
Number of packets received that were less than 256 bytes.
Number of packets received that were greater than 256 bytes and
less than 1514 bytes.
rx_split_pkts
rx_no_comp_wb
Number of packets that were split across two pages.
Number of times the hardware cannot post completion entries for
received data.
rx_no_buf
Number of times the hardware cannot receive data because there is
no more receive buffer space.
rx_new_pages
Number of pages that got replaced during reception.
Chapter 4
Configuring Driver Parameters
57
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 4-12 Transmit and Receive Parameters
Parameter
Description
rx_new_hdr_pgs
Number of pages that were filled with packets less than 256 bytes
that got replaced during reception.
rx_new_mtu_pgs
rx_new_nxt_pgs
rx_hdr_drops
Number of pages that were filled with packets greater than 256
bytes and less than 1514 that got replaced during reception.
Number of pages that contained packets that were split across
pages that got replaced during reception.
Number of times a whole page of packets less than 256 bytes was
dropped because the driver was unable to map a new one to replace
it.
rx_mtu_drops
Number of times a whole page of packets greater than 256 bytes
and less than 1514 was dropped because the driver was unable to
map a new one to replace it.
rx_nxt_drops
rx_rel_flow
Number of times a page with a split packet was dropped because
the driver was unable to map a new one to replace it.
Number of times the driver was told to release a flow.
58
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ To Check Link Partner Settings
● If you are running Solaris 2.6, 7 or 8 operating evironment, type the netstat -k
command as superuser:
# netstat -k ce:0
ce0:
ipackets 0 ipackets64 0 ierrors 0 opackets 0 opackets64 0
oerrors 0 collisions 0 rbytes 0 rbytes64 0 obytes 0 obytes64 0
multircv 0 multixmt 0 brdcstrcv 0 brdcstxmt 0 norcvbuf 0
noxmtbuf 0 first_collision 0 excessive_collisions 0 late_collisions 0
peak_attempts 0 length_err 0 alignment_err 0 crc_err 0 code_violations 0
ifspeed 0 rev_id 1 xcvr_inits 1 xcvr_inuse 3 xcvr_addr 0
xcvr_id 0 cap_autoneg 1 cap_1000fdx 1 cap_1000hdx 0 cap_100T4 0
cap_100fdx 0 cap_100hdx 0 cap_10fdx 0 cap_10hdx 0 cap_asmpause 0
cap_pause 1 lp_cap_autoneg 0 lp_cap_1000fdx 0 lp_cap_1000hdx 0
lp_cap_100T4 0 lp_cap_100fdx 0 lp_cap_100hdx 0 lp_cap_10fdx 0
lp_cap_10hdx 0 lp_cap_asmpause 0 lp_cap_pause 0 link_T4 0
link_speed 0 link_duplex 0 link_asmpause 0 link_pause 0
link_up 0 lb_mode 0 qos_mode 0 tx_inits 0 tx_starts 0 tx_nocanput 0
tx_msgdup_fail 0 tx_allocb_fail 0 tx_no_desc 0 tx_dma_bind_fail 0
tx_uflo 0 tx_queue0 0 tx_queue1 0 tx_queue2 0 tx_queue3 0
tx_max_pend 0 rx_inits 0 rx_hdr_pkts 0 rx_mtu_pkts 0 rx_split_pkts 0
rx_no_buf 0 rx_no_comp_wb 0 rx_ov_flow 0 rx_len_mm 0 rx_bad_descs 0
rx_nocanput 0 rx_msgdup_fail 0 rx_allocb_fail 0 rx_new_pages 0
rx_new_hdr_pgs 0 rx_new_mtu_pgs 0 rx_new_nxt_pgs 0 rx_hdr_drops 0
rx_mtu_drops 0 rx_nxt_drops 0 rx_rel_flow 0 rx_pkts_dropped 0
pci_err 0 pci_rta_err 0 pci_rma_err 0 pci_parity_err 0 pci_bad_ack_err 0
pci_drto_err 0 ipackets_cpu00 0 ipackets_cpu01 0 ipackets_cpu02 0
ipackets_cpu03 0
● If you are running Solaris 9 operating environment, type the kstatcommand as
superuser:
CODE EXAMPLE 4-1 Output from kstatCommand
# kstat ce0
module: ce
name: ce0
instance: 0
class: net
alignment_err
0
0
0
1
1
0
1
1
brdcstrcv
brdcstxmt
cap_1000fdx
cap_1000hdx
cap_100T4
cap_100fdx
cap_100hdx
Chapter 4
Configuring Driver Parameters
59
Download from Www.Somanuals.com. All Manuals Search And Download.
CODE EXAMPLE 4-1 Output from kstatCommand (Continued)
# kstat ce0
cap_10fdx
1
cap_10hdx
1
cap_asmpause
cap_autoneg
cap_pause
0
1
0
code_violations
collisions
crc_err
0
0
0
crtime
2345.407585961
excessive_collisions
first_collision
ierrors
ifspeed
ipackets
ipackets64
ipackets_cpu00
ipackets_cpu01
ipackets_cpu02
ipackets_cpu03
late_collisions
lb_mode
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
length_err
link_T4
link_asmpause
link_duplex
link_pause
link_speed
link_up
lp_cap_1000fdx
lp_cap_1000hdx
lp_cap_100T4
lp_cap_100fdx
lp_cap_100hdx
lp_cap_10fdx
lp_cap_10hdx
lp_cap_asmpause
lp_cap_autoneg
lp_cap_pause
multircv
multixmt
norcvbuf
noxmtbuf
obytes
obytes64
oerrors
opackets
60
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CODE EXAMPLE 4-1 Output from kstatCommand (Continued)
# kstat ce0
opackets64
0
pci_bad_ack_err
pci_dmarz_err
pci_dmawz_err
pci_drto_err
pci_err
0
0
0
0
0
pci_parity_err
pci_rma_err
pci_rta_err
peak_attempts
promisc
0
0
0
0
off
qos_mode
0
rbytes
0
rbytes64
0
rev_id
1
rx_allocb_fail
rx_hdr_drops
rx_hdr_pkts
rx_inits
0
0
0
0
rx_len_mm
0
rx_msgdup_fail
rx_mtu_drops
rx_mtu_pkts
rx_new_hdr_pgs
rx_new_mtu_pgs
rx_new_nxt_pgs
rx_new_pages
rx_no_buf
0
0
0
0
0
0
0
0
rx_no_comp_wb
rx_nocanput
rx_nxt_drops
rx_ov_flow
0
0
0
0
rx_pkts_dropped
rx_rel_bit
0
0
rx_rel_flow
rx_split_pkts
rx_tag_err
0
0
0
rx_taskq_waits
snaptime
0
2352.506837979
tx_allocb_fail
tx_ddi_pkts
tx_dma_bind_fail
tx_dma_hdr_bind_fail
tx_dma_pld_bind_fail
tx_dvma_pkts
tx_hdr_pkts
0
0
0
0
0
0
0
Chapter 4
Configuring Driver Parameters
61
Download from Www.Somanuals.com. All Manuals Search And Download.
CODE EXAMPLE 4-1 Output from kstatCommand (Continued)
# kstat ce0
tx_inits
0
tx_max_desc
tx_max_pend
tx_msgdup_fail
tx_no_desc
tx_nocanput
tx_queue0
tx_queue1
tx_queue2
tx_queue3
tx_starts
tx_uflo
0
0
0
0
0
3
0
0
0
0
0
xcvr_addr
xcvr_id
1
2121809
xcvr_inits
xcvr_inuse
1
1
Additional Uses for the kstatCommand
● Use the kstatcommand to discover link partner capabilities.
# kstat ce:0 | grep lp_
lp_cap_1000fdx
lp_cap_1000hdx
lp_cap_100T4
lp_cap_100fdx
lp_cap_100hdx
lp_cap_10fdx
lp_cap_10hdx
lp_cap_asmpause
lp_cap_autoneg
lp_cap_pause
1
1
0
0
0
0
0
0
1
0
62
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
● Use the kstatcommand to discover link settings.
# kstat ce:0 | grep link
link_T4
0
link_asmpause
link_duplex
link_pause
0
2
0
link_speed
link_up
1000
1
Chapter 4
Configuring Driver Parameters
63
Download from Www.Somanuals.com. All Manuals Search And Download.
64
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
5
Configuring VLANs
This chapter explains VLANs in detail and provides configuration instructions and
examples.
■ VLANs: Virtual Local Area Networks (VLANs) are commonly used to split up
groups of network users into manageable broadcast domains, to create logical
segmentation of workgroups, and to enforce security policies among each logical
segment. With multiple VLANs on an adapter, a server with a single adapter can
have a logical presence on multiple IP subnets. By default, 128 VLANs can be
defined for each VLAN-aware adapter on your server. However, this number can
be increased by changing the system parameters.
If your network does not require multiple VLANs, you can use the default
configuration, in which case no further configuration is necessary.
Note – If you change any of the VLAN configuration parameters, you must reboot
the system before the changes will take effect. If you make changes and do not
reboot, you may experience configuration problems.
An Overview of VLANs
VLANs allow you to split your physical LAN into logical subparts, providing an
essential tool for increasing the efficiency and flexibility of your network.
VLANs are commonly used to separate groups of network users into manageable
broadcast domains, to create logical segmentation of workgroups, and to enforce
security policies among each logical segment. Each defined VLAN behaves as its
own separate network, with its traffic and broadcasts isolated from the others,
increasing the bandwidth efficiency within each logical group.
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Although VLANs are commonly used to create individual broadcast domains and/
or separate IP subnets, it is sometimes useful for a server to have a presence on more
than one VLAN simultaneously. Several Sun products support multiple VLANs on a
per port or per interface basis, allowing very flexible network configurations.
FIGURE 5-1 shows an example network that uses VLANs
.
VLAN 1
VLAN 2
VLAN 3
Main Server
Adapter
Gigabit/Tagged
(All VLANs)
Accounting
Server
(VLAN 3)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10/100 Base
-
TX
Gigabit Ethernet
Shared Media Segment
Software
PC 1
(VLAN 2)
Software
PC 2
(VLAN 2)
Engineering
PC 3
(VLAN 1)
Accounting
PC 4
(VLAN 3)
Engineering/
Software PC 5
Adapter
Gigabit/Tagged
(VLAN 1 & 2)
FIGURE 5-1 Example of Servers Supporting Multiple VLANs with Tagging Adapters
The example network has the following features:
■ The physical LAN network consists of a switch, two servers, and five clients.
■ The LAN is logically organized into three different VLANs, each representing a
different IP subnet.
■ VLAN 1 is an IP subnet consisting of the Main Server, Client 3, and Client 5. This
represents an engineering group.
■ VLAN 2 includes the Main Server, Clients 1 and 2 via shared media segment, and
Client 5. This is a software development group.
■ VLAN 3 includes the Main Server, the Accounting Server and Client 4. This is an
accounting group.
64
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
■ The Main Server is a high-use server that needs to be accessed from all VLANs
and IP subnets. The server has an Sun GigaSwift Ethernet adapter installed. All
three IP subnets are accessed via the single physical adapter interface. The server
is attached to one of the SunSwitch’s Gigabit Ethernet ports, which is configured
for VLANs 1, 2, and 3. Both the adapter and the connected SunSwitch port have
tagging turned on. Because of the tagging VLAN capabilities of both devices, the
sever is able to communicate on all three IP subnets in this network, but continues
to maintain broadcast separation between all of them.
■ The Accounting Server is available to VLAN 3 only. It is isolated from all traffic
on VLANs 1 and 2. The switch port connected to the server has tagging turned
off.
■ Clients 1 and 2 are attached to a shared media hub that is then connected to the
switch. They belong to VLAN 2 only, and are logically in the same IP subnet as
the Main Server and Client 5. The switch port connected to this segment has
tagging turned off.
■ Client 3 is a member of VLAN 1, and can communicate only with the Main Server
and Client 5. Tagging is not enabled on Client 3’s switch port.
■ Client 4 is a member of VLAN 3, and can communicate only with the servers.
Tagging is not enabled on Client 4’s switch port.
■ Client 5 is a member of both VLANs 1 and 2, and has a Sun GigaSwift Ethernet
adapter installed. It is connected to switch port 10. Both the adapter and the
switch port are configured for VLANs 1 and 2 and have tagging enabled.
VLAN tagging is only required to be enabled on switch ports that create trunk links
to other VLAN-aware Ethernet switches, or on ports connected to tag-capable end-
stations, such as servers or workstations with VLAN-aware adapters.
Configuring VLANs
VLANs can be created according to various criteria, but each VLAN must be
assigned a VLAN tag or VLAN ID (VID). The VID is a 12-bit identifier between 1
and 4094 that identifies a unique VLAN. For each network interface (ce0, ce1, ce2
and so on), 4094 possible VLAN IDs can be selected. Only 512 unique IDs can be
used simultaneously. Because IP subnets are commonly used, it is best to use IP
subnets when setting up a VLAN network interface. This means that each VID
assigned to a VLAN interface of a physical network interface will belong to different
subnets.
Chapter 5
Configuring VLANs
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Tagging an Ethernet frame requires the addition of a tag header to the frame. The
header is inserted immediately following the Destination MAC address and the
Source MAC address. The tag header consists of two bytes of Ethernet Tag Protocol
Identifier (TPID, 0x8100) and two bytes of Tag Control Information (TCI). FIGURE 5-2
shows the Ethernet Tag Header format.
Octet
1
TPID (0x8100
2
3
4
3 bits
1
bit
12 bytes
User_priority
VID
CFI
FIGURE 5-2 Ethernet Tag Header Format
By default, a single VLAN is configured for every port, which groups all ports into
the same broadcast domain, just as if there were no VLANs at all, VLAN tagging for
the switch port turned off.
Note – If you configure a VLAN virtual device for an adapter, all traffic sent or
received by that adapter must be in VLAN-tagged format.
▼ To Configure Static VLANs
1. Create one hostname6.cenum file for each VLAN which will be configured for each
adapter on the server, using the following naming format that includes both the
VID and the physical point of attachment (PPA):
VLAN logical PPA = <1000 * VID> + <Device PPA>
ce123000 = 1000*123 + ce
This format limits the maximum number of PPAs (instances) you can configure to
1000 in the /etc/path_to_instfile.
For example, on a server with the Sun GigaSwift Ethernet adapter having an
instance of 0, that belongs to a member of two VLANs, with VID 123 and 224, you
would use ce123000and ce224000, respectively, as the two VLAN PPAs.
66
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Use the ifconfig(1M)to configure a VLAN virtual device, for example:
# ifconfig ce123000 plumb up
# ifconfig ce224000 plumb up
The output of ifconfig -aon a system having VLAN devices ce123000and
ce224000:
# ifconfig -a
lo0: flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4> mtu 8232 index 1
inet 127.0.0.1 netmask ff000000
hme0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2
inet 129.144.131.91 netmask ffffff00 broadcast 129.144.131.255
ether 8:0:20:a4:4f:b8
ce123000: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 3
inet 199.199.123.3 netmask ffffff00 broadcast 199.199.123.255
ether 8:0:20:a4:4f:b8
ce224000: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 4
inet 199.199.224.3 netmask ffffff00 broadcast 199.199.224.225
ether 8:0:20:a4:4f:b8
3. On the switch, set VLAN tagging and set VLAN ports to coincide with the VLANs
you’ve set up on the server. Using the examples in Step 2, you would set up VLAN
ports 123 and 224 on the switch.
Refer to the documentation that came with your switch for specific instructions for
setting VLAN tagging and ports.
Chapter 5
Configuring VLANs
67
Download from Www.Somanuals.com. All Manuals Search And Download.
68
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
A
Specifications
This appendix lists the specifications for the Sun GigaSwift Ethernet adapter. It
contains the following sections:
■ “Connectors” on page 69
■ “Performance Specifications” on page 70
■ “Physical Characteristics” on page 71
■ “Power Requirements” on page 71
Connectors
FIGURE A-1 shows the connector for the Sun GigaSwift Ethernet MMF adapter.
FIGURE A-1 Sun GigaSwift Ethernet MMF Adapter Connector
TABLE A-1 lists the characteristics of the SC connector (850 nm).
TABLE A-1 SC Connector Link Characteristics (IEEE P802.3z)
Description
62.5 Micron MMF
50 Micron MMF
Operating range
Up to 260 meters
Up to 550 meters
69
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE A-2 shows the connector for the Sun GigaSwift Ethernet UTP adapter.
FIGURE A-2 Sun GigaSwift Ethernet UTP Adapter Connector
Table A-2 lists the characteristics of the Cat-5 Connector used by the Sun GigaSwift
Ethernet UTP adapter.
TABLE A-2 Cat-5 Connector Link Characteristics
Description
Operating range
Up 100 meters
Performance Specifications
TABLE A-3 Performance Sepcifications
Feature
Specification
PCI clock
33/ 66 MHz max
up to 64-byte bursts
32/ 64 -bit
PCI data burst transfer rate
PCI data/ address width
PCI modes
Master/ slave
1 GBit/ s, 850 nm
1000 Mbps (full duplex)
70
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Physical Characteristics
TABLE A-4 Physical Characteristics
Dimension
Length
Width
Measurement
6.8 inches
4.2 inches
Power Requirements
TABLE A-5 Power Requirements
Specification
Measurement
Maximum power consumption
Voltage
12 watts (MMF) 15 watts (UTP)
3.3V and 5V
Appendix A
Specifications
71
Download from Www.Somanuals.com. All Manuals Search And Download.
72
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
B
Diagnostic Software and
Troubleshooting Issues
instructions for testing the adapter using the onboard FCode self-test. There is also a
section outlining some common troubleshooting issues. This appendix contains the
following sections:
■ “SunVTS Diagnostic Software” on page 73
■ “Using the OpenBoot PROM FCode Self-Test” on page 74
■ “Troubleshooting Issues” on page 76
SunVTS Diagnostic Software
The SunVTS software executes multiple diagnostic hardware tests from a single user
interface and is used to verify the configuration and functionality of most hardware
controllers and devices. The SunVTS software operates primarily from a graphical
user interface, enabling test parameters to be set quickly and easily while a
diagnostic test operation is being performed.
The nettestand the netlbtestcheck all the networking interfaces on a system,
including the Sun GigaSwift Ethernet adapter. Refer to the SunVTS User’s Guide for
more information on how to run the nettestdiagnostic test.
Note – To use the nettestor netlbtestdiagnostic, you must have the SunVTS
software installed on your system. Refer to the Solaris Sun Hardware Platform Guide,
which was shipped with the Solaris Supplement CD, for instructions on how to install
the SunVTS software.
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the OpenBoot PROM FCode Self-
Test
The following tests are available to help identify problems with the adapter if the
system does not boot.
You can invoke the FCode self-test diagnostics by using the OpenBoot user interface
testor test-allcommands. If you encounter an error while running diagnostics,
appropriate messages will be displayed. Refer to the appropriate OpenBoot Command
Reference Manual for more information on the testand test-allcommands.
The FCode self-test exercises most functionality sub-section by sub-section and
ensures the following:
■ Connectivity during adapter card installation
■ Verification that all components required for a system boot are functional
▼ Running the Ethernet FCode Self-Test Diagnostic
To run the Ethernet diagnostics, you must first bring the system to a stop at the
OpenBoot prompt after issuing a reset. If you do not reset the system, the diagnostic
tests might cause the system to hang.
For more information about the OpenBoot commands in this section, refer to the
appropriate OpenBoot Command Reference Manual.
1. Shut down the system.
Use the standard shutdown procedures described in the Solaris Handbook for Sun
Peripherals.
2. At the okprompt, set the auto-boot?configuration variable to false.
ok setenv auto-boot? false
3. Reset the system.
ok reset-all
74
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Type show-netsto display the list of devices.
You should see a list of devices, similar to the example below, specific to the adapter:
ok show-nets
a) /pci@1f,0/pci@1/network@4
b) /pci@1f,0/pci@1,1/network@1,1
q) NO SELECTION
Enter Selection, q to quit:
5. Type the following to run the self-test using the testcommand:
ok test device path
The following tests are run when the testcommand is executed:
■ ceregister test (happens only when diag-switch?is true)
■ internal loopback test
■ link up/ down test
If the testpasses, you see these messages:
ok test /pci@1f,0/pci@1/network@4
ce register test --- succeeded.
Internal loopback test -- succeeded.
Link is -- up
If the card is not connected to a network, you see the following messages:
ok test /pci@1f,0/pci@1/network@4
ce register test --- succeeded.
Internal loopback test -- succeeded.
Link is -- down
ok
6. After testing the adapter, type the following to return the OpenBoot PROM to
standard operating mode:
ok setenv diag-switch? false
Appendix B
Diagnostic Software and Troubleshooting Issues
75
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Set the auto-boot?configuration parameter to true.
ok setenv auto-boot? true
8. Reset and reboot the system.
Refer to the appropriate OpenBoot Command Reference Manual for more information.
Troubleshooting Issues
Known Incompatibilities with Pre-IEEE 802.3z
Network Switches
You might experience interoperability issues when using the Sun
GigaSwift Ethernet adapter with the SunSwitch switch, the Alteon ACE 110 switch,
or other pre- or non-IEEE 802.3z standard compliant network equipment. If you
experience difficulties with noncompliant equipment, set the adapter and switch
autonegotiation properties to offand try to configure the interface manually.
▼ To Set Autonegotiation to offfor a SunSwitch
or an Alteon ACE 110 Switch
You can set autonegotiation to offfor SunSwitch and Alteon ACE 110 switches
using those switches’ configuration program (cgf). Refer to your switch
documentation for instructions on how to access and use the cgfprogram.
The following procedure describes how to turn autonegotiation off for one
SunSwitch port.
1. Establish a connection to the switch using either a serial connection or a Telnet
connection.
Refer to the SunSwitch 1.1 Installation and Configuration Guide (805-3743-10) for more
information. After connecting to the switch, the Main menu prompt (Main#) is
displayed.
76
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
2. At the Main#prompt, type cfgto display the Configuration menu and prompt
(Configuration#).
>> Main# cfg
[Configuration Menu]
sys - System-wide parameter menu
port - Port configuration menu
ip
- IP addressing menu
vlan - VLAN configuration menu
stp - Spanning Tree menu
snmp - SNMP menu
setup - Step by step configuration set up
dump - Dump current configuration to script file
>> Configuration#
3. Type the following to disable autonegotiation on a GigaSwift Ethernet port.
Replace portnumber with the Ethernet port used by the adapter.
>> Configuration# /port portnumber/auto off
4. Type the following to apply and save your changes.
>> Configuration# apply
>> Configuration# save
Refer to the switch documentation for further configuration instructions.
▼ To Set Autonegotiation to offfor Other
Noncompliant Network Equipment
If your network equipment does not support autonegotiation, you can set
autonegotiation to offon the GigaSwift Ethernet (ce) device.
1. Set the following GigaSwift Ethernet driver parameters to values according to the
documentation that shipped with your switch:
■ adv-1000fdx-cap
■ adv-1000hdx-cap
■ adv-ampause-cap
■ adv-pause-cap
Appendix B
Diagnostic Software and Troubleshooting Issues
77
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Set the adv-autoneg-capparameter to 0.
Note – See Chapter 4 for the default values of these parameters and for instructions
on how to set these parameters.
Failure to Configure GigaSwift Ethernet Instance
If your machine fails to configure a GigaSwift Ethernet instance, yet prtconf
indicates the adapter is present, the problem may be due to residue adapter
instances in the path_to_instfile.
To solve this problem, open the path_to_instfile for editing and remove the lines
containing cedevice path.
Non-Specific Issues
TABLE B-1 describes the problems you may encounter in using the GigaSwift Ethernet
adapter as well as a solution for them:
TABLE B-1 Troubleshooting the GigaSwift Ethernet Adapter
Problem
Description
Solution
prtdiagdoes not
recognize the NIC in
slot 0.
If a PCI I/ O board of an UltraSPARC III system is filled
with network adapters with an internal bridge (for
example, GigaSwift Ethernet or Quad FastEthernet),
prtdiagdisplays the card on slot 0. Although the card
in slot 1 is not recognized by prtdiag, the card is fully
operational and appears in the /etc/path_to_inst
file.
Use prtconf -pv
instead of prtdiag
VLAN appears to
accept VID 0 as end
user input.
ce000000, ce00000,or ce0000configured as VID 0
is actually the regular ce0interface not VID 0of the
ce0interface. VID 0is not supported as an end user
device.
This is normal behavior.
78
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE B-1 Troubleshooting the GigaSwift Ethernet Adapter (Continued)
Problem
Description
Solution
System panics in
Solaris 7 11/ 99
The GigaSwift Ethernet driver uses certain not
suspendable kernel threads. When CPR attempts to
• Turn off CPR.
• A CPR fix is
environment when
CPR attempts to
suspend a non-
suspendable thread
suspend the driver, the system panics. Currently, CPR is incorporated in Solaris 8.
supported only in Sun desktop systems (for example,
Ultra 10 and Ultra 60).
Inetbootmay require Systems with OBP 4.x (for example, Sun Blade 1000)
Ignore these console
messages until booting is
complete
several retries to
may automatically retry several times before
completing. The message below is displayed for each
retry:
complete with OBP 4.x
Retrying ... Check TFTP server and network setup
Problem with DR Attach on Sun
Enterprise Platforms
DR attach does not configure ceinterfaces on Sun Enterprise™ 10000 platforms
running the Solaris 2.6 operating environment. To add DR support for ce interfaces
on such systems, make the following changes:
1. Add the following lines to the /etc/systemfile:
set dr:detach_safe_list1="ce"
set hswp:suspend_safe_list1="ce"
2. Reboot system.
Appendix B
Diagnostic Software and Troubleshooting Issues
79
Download from Www.Somanuals.com. All Manuals Search And Download.
80
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
SYMBOLS
E
.properties command, 18
/ etc/ hostname.cenumber file, 26
FCode selftest diagnostics, 74
fiber optic cable connection, 15
flow control keywords, 41
A
assigning an IP address, 26
autonegotiation
C
CAT-5 twisted-pair cable, 15
ce driver parameter, status, and descriptions, 38
configuring device driver parameters, 37
configuring the driver parameters, 37
I
installing the Solaris operating environment over
the network, 29
D
device properties, 18
diagnostic support, 7
diskless clients, 27
L
Dynamic Reconfiguration, 14
dynamic reconfiguration, 9
Dynamic Reconfiguration (DR), 21
link partner, 37
link partner settings
Index
81
Download from Www.Somanuals.com. All Manuals Search And Download.
M
V
MAC address, 19
verify the installation, 16
virtual device, 67
VLAN ID, 65
VLAN naming format, 66
VLANs, 63
N
ndd utility, 48
NVRAM configuration, 19
O
P
parameter values
R
random early detection register, 45
receive interrupt blanking values, 39, 44
S
setting ce driver parameters
using ndd
using ce.conf, 47
standard Ethernet frame sizes, 6
standards and protocols, 6
SunVTS diagnostic application, 73
82 Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
|