Stovax Indoor Fireplace AR0366 User Manual

Steel Manhattan  
Coal Effect Stove Range  
Conventional Flue  
With upgradeable control valve  
Instructions for Use,  
Installation and Servicing  
For use in GB, IE (Great Britain and Eire)  
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the  
translated instructions and in some cases the appliance will require modification. Contact Gazco for further information.  
IMPORTANT  
Do not attempt to burn rubbish in this fire. This stove must only be operated with the door secured firmly in position.  
The outer casing of this stove will become hot whilst in operation, it is therefore recommended that the appliance be  
guarded to protect the young and infirm using a suitable guard.  
Ensure that fabrics such as curtains are not positioned above or near to the stoves outer casing.  
Please read these Instructions carefully and keep them in a safe place.  
They will be needed when servicing the fire.  
The commissioning sheet found on page 3 should be completed by the installer.  
PR0617 Issue 4 (February 2007))  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLIANCE COMMISSIONING CHECKLIST  
IMPORTANT NOTICE  
Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,  
as the information will be required when making any guaranteed claims.  
FLUE CHECK  
PASS  
FAIL  
1.  
2.  
3.  
Flue is correct for appliance  
Flue flow test  
Spillage test  
GAS CHECK  
1.  
2.  
3.  
Gas soundness & let by test (Please circle Y / N as appropriate)  
Y / N  
m3/h  
Y / N  
mb  
Standing pressure test in figures (e.g. 20 mb)  
Appliance working pressure (on High Setting) in figures (e.g. 20 mb)  
NB All other gas appliances must be operating on full  
Gas rate  
mb  
4.  
5.  
6.  
Does ventilation meet appliance requirements  
Have controls been upgraded (Upgradeable models only)  
8455 Standard  
YES  
YES  
NO  
NO  
8456 Programmable Time & Temperature  
DEALER AND INSTALLER INFORMATION  
Dealer.......................................................................  
................................................................................  
................................................................................  
Contact No. ...............................................................  
Date of Purchase........................................................  
Model No. .................................................................  
Serial No. ..................................................................  
Gas Type...................................................................  
Installation Company..................................................  
.................................................................................  
.................................................................................  
Engineer ....................................................................  
Contact No.................................................................  
Corgi Reg No..............................................................  
Date of Installation.....................................................  
This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your  
local Gazco dealer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance Commissioning Checklist is  
not fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid during the  
second year, to the extent permitted by law, if the annual service recommended in the Instructions for Use has been completed by a  
Corgi registered engineer, and a copy of the service visit report is available for inspection by a Gazco engineer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
USER INSTRUCTIONS  
1.12 In all correspondence, please quote the appliance type and  
serial number which can be found on the databadge at the  
rear of the stove.  
1. GENERAL  
1.13 This product is guaranteed for 2 years from the date of  
installation, as set out in the terms and conditions of sale  
between Gazco and your local Gazco dealer. Please consult  
with your local Gazco dealer if you have any questions. In  
all correspondence always quote the Model No. and Serial  
No. Please ensure the commissioning checklist is completed  
by your installer; this is a requirement of your Guarantee.  
1.1 Installation and servicing must be carried out by a  
competent person in accordance with Gas Safety  
(Installation and Use) Regulations 1998, the relevant British  
Standards for Installation, appropriate Codes of Practice and  
in accordance with the manufacturers instructions. It is a  
requirement that a CORGI registered engineer be used for  
this purpose as they are approved by the HSE under the  
above regulations.  
1.2 This appliance is suitable for use in G.B. and I.E. using  
Natural Gas at a supply pressure of 20mbar or LPG at a  
supply pressure of 29mbar (Butane) or 37mbar (propane).  
2. LIGHTING THE APPLIANCE  
2.1 Locate the control valve on the appliance. There are two  
control knobs on the valve:  
1.3 The installation shall also be completed in accordance with:  
The Building Regulations issued by The Department of The  
Environment.  
The Building Standards (Scotland) Regulations issued by the  
Scottish Development Department.  
For Republic of Ireland, reference should be made to the  
relevant standards governing installations (IS813:1996)  
- right controls the pilot ignition  
- left controls the main burner.  
2.2 If your appliance has already been upgraded to battery  
remote control, please refer to the instructions provided  
with the upgrade to operate the remote control. The  
1.4 Read all these instructions before commencing installation.  
1.5 This appliance must be installed in accordance with the  
rules in force and only used in a sufficiently ventilated  
space.  
2
1.6 Ensure that curtains are not positioned above the stove, and  
that there is at least a clearance of 300mm between the  
sides of the stove and any curtains.  
1.7 The manufacturer considers the full outer casing of this  
stove to be a working surface which becomes hot whilst in  
operation. A suitable guard is recommended to protect  
young children, the aged and the infirm.  
1.8 This stove must only be operated with the door secured  
firmly in position. If any cracks appear in the glass the  
appliance must not be used until the glass panel is replaced.  
AR0914  
following instructions work for either situation.  
2.3 Ensure that the left-hand control knob is pointing to off ( ).  
2.4 Ensure that the right-hand control knob is pointing to off ( ).  
2.5 Press in the right-hand control knob and, keeping he knob  
depressed, turn it anti-clockwise until a click is heard and  
the knob is pointing to pilot ( ). The pilot should now  
light. If the pilot does not light, release the knob and repeat  
the procedure until it does.  
2.6 Keep the control knob pressed in for 10 seconds and then  
release it, the pilot should stay alight. If the pilot goes out,  
repeat the procedures until it remains lit.  
2.7 If the pilot does not light after repeated attempts, contact  
the retailer or installer from whom the appliance was  
purchased.  
1.9 Do not attempt to burn rubbish in this stove.  
1.10 Any combustible shelves or surrounding furniture must only  
be fitted in accordance with the minimum dimensions  
detailed in diagram 1.  
1
2.8 Turn the right-hand control to point to main burner ( ).  
The appliance can now be controlled using the left-hand  
control knob.  
2.9 Turn the left-hand control knob to point to low fire ( ),  
the main burner lights on low. The burner can now be  
controlled between low and high settings. Turn the control  
knob anticlockwise to increase the flame height and  
clockwise to decrease the flame height.  
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE  
HAS REACHED SUFFICIENT HEAT - TYPICALLY 10 TO 20  
MINUTES.  
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN  
USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RE-  
LIGHT THE APPLIANCE.  
1.11 Contact a competent service engineer to carry out relevant  
spillage checks etc. following home improvements carried  
out after installation of this stove (e.g. the fitting of double  
glazing).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
USER INSTRUCTIONS  
Protective clothing is not required when handling these  
articles, but we recommend you follow normal hygiene  
rules of not smoking, eating or drinking in the work area  
and always wash your hands before eating or drinking.  
To ensure that the release of RCF fibres are kept to a  
minimum, during installation and servicing a HEPA filtered  
vacuum is recommended to remove any dust accumulated  
in and around the appliance before and after working on it.  
When servicing the appliance it is recommended that the  
replaced items are not broken up, but are sealed within  
heavy duty polythene bags and labelled as RCF waste.  
3. TURNING THE STOVE OFF  
3.1 To turn the stove off, locate the control valve, turn the left-  
hand control knob until it points to off ( ). The main  
burner goes out leaving the pilot burning.  
3.2  
To turn the pilot off, locate the control valve, turn the right-  
hand control knob until it points to off ( ), the pilot goes out.  
4. UPGRADING YOUR STOVE  
RCF waste is classed as stable, non-reactive hazardous  
waste and may be disposed of at a licensed landfill site.  
Excessive exposure to these materials may cause temporary  
irritation to eyes, skin and respiratory tract; wash hands  
thoroughly after handling the material.  
4.1  
Your stove is fitted with a control valve that can easily be  
upgraded to battery powered remote control. This upgrade can  
be fitted by anyone capable of simple DIY jobs and requires no  
special training. There are two versions of this control which  
can be obtained through your local Gazco stockist.  
6. FUEL BED ARRANGEMENT  
4.2 STANDARD REMOTE CONTROL. This remote controls the  
gas appliance after the pilot has been lit. It can turn the  
main burner on and regulate it from low through to high  
and back again. It can turn the main burner off leaving the  
pilot burning GAZCO PART NUMBER 8455.  
4.3 THERMOSTATIC AND TIMER REMOTE CONTROL. This  
remote controls the gas appliance after the pilot has been  
lit. In ‘MANUAL MODE’ it can be used to turn the main  
burner on and manually regulate it from low through to  
high and back again. It can also be used to turn the main  
burner leaving the pilot burning. In ‘AUTO MODE’ it will  
automatically regulate the room temperature to a pre-set  
temperature. In ‘TIMER MODE’ it will turn the fire on and  
off according to a pre-set programme and automatically  
regulate the room temperature during the two ON periods.  
GAZCO PART NUMBER 8456.  
To access the ceramic fuel pieces, it will be necessary to  
remove the glass door. Lift off the decorative steel trim, see  
Diagram 3 and remove the 6 screws holding the glass  
frame. See Diagram 4.  
3
5. CLEANING THE FIRE  
WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE  
UNTIL IT IS COLD. THE STOVE RETAINS ITS HEAT FOR  
A CONSIDERABLE TIME AFTER SHUTDOWN.  
4
5.1 Carefully remove the ceramic fuel bed components and  
place to one side taking care to protect floor coverings etc,  
PLEASE HANDLE WITH CARE.  
5.2 The coals should not require cleaning. Do not use a  
vacuum cleaner or brush to clean the coals, any large pieces  
of debris can be removed by hand.  
5.3 Ensure any debris is removed from the burner ports.  
5.4 Replace the ceramics by referring to section 6.  
5.5 Use a damp cloth to clean the outer casing of the  
appliance.  
Advice on Handling and disposal of fire ceramics  
5.6 The fuel effect and side panels in this appliance are made  
from Refractory Ceramic Fibre (RCF), a material which is  
commonly used for this application.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
USER INSTRUCTIONS  
6.4 Place two small coals at each end of the front coal so that  
Steel Manhattan  
they lean against the flame baffle, and a further two large  
coals on the flame baffle, one at each end, see diagram 8.  
6.1 Place the flame baffle onto the shelf at the rear of the tray  
and push up against the rear ledge, see diagram 5.  
8
5
AR0368  
6.5 Place five small coals along the rear of the flame baffle,  
resting against the rear ledge, see diagram 9.  
AR0365  
6.2 Locate the front coal moulding in front of the flame baffle  
ensuring that the end legs sit flat against the burner skin, see  
diagram 6.  
9
6
AR0369  
6.6 Ensure that the rope seal on the back of the glass frame is  
intact. Replace the glass frame ensuring that the 6 screws are  
tightened evenly. DO NOT OVERTIGHTEN. see diagram 10.  
AR0366  
10  
6.3 Place three large coals on the front coal so that they lean  
against the flame baffle, and the four large coals on the  
flame baffle so that they sit on the fingers, see diagram 7.  
7
AR0887  
NEVER OPERATE THE STOVE WHEN THE DOOR IS  
REMOVED OR WHEN THE GLASS IS BROKEN.  
AR0367  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
USER INSTRUCTIONS  
7. GAZCO FLUE SURE SYSTEM  
7.1 The stove is fitted with the Gazco Flue Sure System, which  
will act to cut off the gas supply to the burner in the event  
of incorrect operation of the flue. If the system acts to cut  
off the gas supply, this indicates that there is insufficient flue  
pull. If this occurs a minimum of 10 minutes should be  
allowed before trying to relight. Continued operation of this  
safety device means there may be a serious problem with  
the flue system. A qualified gas engineer should inspect this.  
Do not use the stove until an engineer says it is safe to  
do so.  
8. THE FLAME FAILURE DEVICE  
8.1 This is a safety feature incorporated in all GAZCO fires,  
which automatically switches off the gas supply if the pilot  
light goes out and fails to heat the thermocouple.  
9. 'RUNNING IN'  
9.1 The surface coating on your GAZCO stove will ‘burn off’  
during the first 24 hours of operation on high, producing a  
harmless and temporary odour. If the odour persists ask  
your retailer for advice.  
10. SERVICING  
10.1 A qualified gas engineer must service the stove every 12  
months. In all correspondence, always quote the appliance  
type and the Serial Number found on the data badge on  
the appliance.  
11. VENTILATION  
11.1 Any purpose provided ventilation should be checked  
periodically to ensure it is free from obstruction.  
12. INSTALLATION DETAILS  
12.1 To assist in any future correspondence, your installer should  
have completed the Appliance Commissioning Checklist in  
this manual. This records the essential installation details of  
this appliance. In all correspondence always quote the  
Model No. and Serial No.  
13. HOT SURFACES  
13.1 Parts of this appliance become hot during normal use. It is  
recommended that a suitable fire guard be used for  
protection of young children and the infirm. Indeed, all  
parts of the appliance should be treated as a ‘working  
surface’ except for the control area.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
INSTALLATION INSTRUCTIONS  
TECHNICAL SPECIFICATION  
Covering Models:  
MANHATTAN - 8619 - P8619  
Model  
CAT.  
Gas  
Gas  
Type  
Working NOX Aeration  
Pressure Class  
Injector Gas Rate Input kW (Gross) Country  
m3h  
High  
Low  
Steel Manhattan 8619  
Steel Manhattan P8619  
6.6  
Gross  
6.6  
Gross  
Naural Gas G20  
20 mbar  
5
5
ø11 mm  
375  
170  
0.629  
GB,IE  
GB,IE  
I2H  
LPG Propane G31 37 mbar  
LPG Butane G30  
0.237  
0.18  
6.30  
Gross  
3.25  
Gross  
ø15.5 x 2  
I3+  
29 mbar  
Efficiency Class II  
Flue Outlet Size 127 mm (5”) ø  
Gas Inlet Connection Size 8 mm ø  
Minimum flue specification T300/N2/O/D/1  
Maximum flue temperature 260°C  
A
C
Packing Checklist  
Qty Description  
1
1
1
1
1
1
1
1
2
2
1
Stove  
Flue Blanking plate  
Flue In fill plate  
Coal set*  
B
D
Flame Baffle*  
Front Coal*  
Fixing kit containing  
Instruction Manual  
Wood screws  
Rawlplugs  
E
Box spanner  
AA  
*Packed in appliance  
A
B
C
D
E
ins  
27 / 709  
mm ins  
27  
mm ins  
683 16 /  
mm ins  
42 17 /  
mm ins  
mm  
145  
7
3
7
3
8
4
8
4
453 5 /  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
INSTALLATION INSTRUCTIONS  
SITE REQUIREMENTS  
1
1. FLUE AND CHIMNEY REQUIREMENTS  
1.1  
1.2  
The chimney or flue system must comply with the rules in  
force, and must be a minimum of 127mm in diameter. (5").  
A = 811mm  
B = 527 mm  
C = 12 mm  
The minimum height of the flue or chimney must be 3 metres  
(10ft). Any horizontal flue run from the rear outlet should not  
exceed 100mm from the back of the appliance.  
AR0604  
1.3  
1.4  
The chimney or flue must be free from any obstruction. Any  
damper plates should be removed or secured in the fully open  
position and no restrictor plates should be fitted.  
MINIMUM CLEARANCE  
The chimney should be swept prior to the installation of the  
appliance, but where it can be seen that the chimney is clean  
and unobstructed throughout its entire length, it need not be  
swept.  
4.3 The stove is not suitable for installation against a  
combustible wall. All combustible materials must be  
removed from behind the stove.  
4.4 Ensure you comply with all minimum clearance  
NOTE: If it is intended to fit the stove into an existing brick-  
built chimney without a closure plate*, a 5" (127mm) liner  
must be used. Larger lined flues may work, but in some  
instances could cause cold start flue problems resulting in  
nuisance shutdown. Lined flues above 7" (175mm) are not  
recommended.  
measurements, whether or not to combustible materials.  
2
2. VENTILATION  
2.1 The large stove has a rated output in excess of 7Kw and  
requires a minimum of 11cm2 permanent effective free air.  
This is in addition to any window that opens, and although  
it must communicate with the outside air whenver possible,  
it can communicate with an adjacent room providing such  
space has a similar opening to the outside. The small and  
medium stoves have a rated output below 7Kw and do not  
normally require any additional ventilation.  
2A  
3. INSTALLATION OF THE GAS SUPPLY  
*
3.1 Before installation, ensure the local distribution conditions  
(identification of the type of gas and pressure) and the  
adjustment of the appliance are compatible.  
3.2 Ensure that the gas supply is capable of delivering the  
required amount of gas, and is in accordance with the rules  
in force.  
3.3 Soft copper tubing and soft soldered joints can be used but  
must not be closer than 50mm to the base of the tray.  
* Air-space to non-combustible  
3.4 A means of isolating the gas supply to the appliance must  
be provided, independent of any appliance control.  
3.5 All supply gas pipes must be purged of any debris that may  
have entered, prior to connection to the appliance.  
The above dimensions povide adequate clearance at the  
side and rear of the fire so that the controls can be  
reached.  
4. APPLIANCE LOCATION  
4.1 This stove must stand on a non-combustible hearth that is at  
least 12mm thick and projects 50mm minimum from the  
base of the stove in all directions.  
4.2 Do not install in a room that contains a bath or shower.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
INSTALLATION INSTRUCTIONS  
INSTALLATION  
IMPORTANT: ENSURE THAT THE APPLIANCE IS  
1
CORRECTLY ADJUSTED FOR THE GAS TYPE AND  
CATEGORY APPLICABLE IN THE COUNTRY OF USE.  
REFER TO DATABADGE AND TECHNICAL  
SPECIFICATIONS OF THIS BOOKLET.  
FOR DETAILS OF CHANGING BETWEEN GAS TYPES  
REFER TO SERVICING INSTRUCTIONS, REPLACING  
PARTS.  
1. CONTROL UPGRADE  
1.1 This stove is fitted with a control valve that can be easily  
upgraded to battery powered remote control. There are two  
versions of this control which can be obtained through your  
local Gazco stockist.  
1.2 This upgrade can be fitted before or after installation but if  
side clearances are limited then it will be easier to upgrade  
the stove before installation. Full instructions are included  
with the kit.  
1.3 STANDARD REMOTE CONTROL. This remote controls the  
gas appliance after the pilot has been lit. It can turn the  
main burner on and regulate it from low through to high  
and back again. It can turn the main burner off leaving the  
pilot burning GAZCO PART NUMBER 8455.  
1.4 THERMOSTATIC AND TIMER REMOTE CONTROL. This  
remote controls the gas appliance after the pilot has been  
lit. In ‘MANUAL MODE’ it can be used to turn the main  
burner on and manually regulate it from low through to  
high and back again. It can also be used to turn the main  
burner leaving the pilot burning. In ‘AUTO MODE’ it will  
automatically regulate the room temperature to a pre-set  
temperature. In ‘TIMER MODE’ it will turn the fire on and  
off according to a pre-set programme and automatically  
regulate the room temperature during the two ON periods.  
GAZCO PART NUMBER 8456.  
2.7 The stove is fitted with the Gazco Flue Sure System, which  
acts to cut off the gas supply to the appliance in the event  
of incorrect operation of the flue. If the system acts to shut  
off the gas supply, this indicates there is insufficient flue  
pull. If this occurs a minimum of 10 minutes should be  
allowed before trying to relight. Continued operation of this  
safety device means there may be a serious problem with  
the flue system and a qualified gas engineer must inspect.  
DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT  
IS SAFE TO DO SO.  
2.8 Do not tamper with the Flue Sure System Use only genuine  
Gazco replacement parts when servicing the system - refer  
to Servicing Instructions, Replacing Parts.  
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE  
HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20  
MINUTES.  
3. INSTALLATION OF THE STOVE  
3.1 Open the carton containing the engine assembly, and  
carefully remove the engine. It will now be necessary to  
decide upon top or rear flue exit, the stove is factory built  
for rear flue exit, but it may be changed to top exit by  
simply using the following method.  
2. SAFETY PRECAUTIONS  
3.2 Remove the flue spigot from the rear of the stove and  
replace with the blanking plate from the top of the stove.  
Refit flue spigot to top of stove.  
3.3 When installing with a top flue please note the flue pipe fits  
through a hole in the top grill, the dimensions are for floor  
fixing a top flue installation with clearance for side panels.  
3.4 Position the engine assembly in its intended location and  
mark the position of the two floor fixing holes at the base of  
each side of the subframe, minimum fixing dimensions to a  
rear wall are shown in diagram 2.  
2.1 This appliance must be installed in accordance with the  
rules in force and used only in a sufficiently ventilated  
space. Place read these instructions before installation and  
use of this appliance.  
2.2 All the instructions must be left intact with the user.  
2.3 In your own interest, and those of safety, this appliance  
must be installed by a competent person in accordance  
with local and national codes of practice. Failure to install  
the appliance correctly could lead to prosecution.  
2.4 This appliance is intended for use on a governed gas  
installation and set to the required pressure.  
2.5 Keep all plastic bags away from young children.  
2.6 Do not place any object on or near to the stove. Allow  
adequate clearance above the stove. See diagram 2,  
Appliance Location..  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
0
INSTALLATION INSTRUCTIONS  
INSTALLATION  
3.5 Remove the assembly and drill the two holes using a No. 12  
4
masonry bit. Push the rawl plugs into the holes, and place  
the engine assembly in position, secure to the floor using  
the screws provided. See diagram 2.  
2
AR0879  
158mm  
AR0631  
AR0878  
3.8 Secure the upper front panel using the 4 nuts and bolts  
provided. See diagram 5.  
3.4 Having run the gas supply to the stove, PURGE THE  
SUPPLY PIPE, this is essential to expel any debris that may  
block the gas controls. connect the gas supply to the 8mm-  
compression elbow at the RH rear corner of the stove,  
ensuring that the pipe position does not interfere with the  
location of the outer steel casing. See diagram 3.  
5
3
3.9 Locate the lower panels onto the lugs as shown. See  
diagram 6.  
6
3.7 Open the second carton and carefully remove the steel  
outer casing components. Remove the protective plastic  
coating from the two side assemblies and lower them onto  
the engine assembly until the lugs locate as shown, check  
that the feet are touching the hearth. See diagram 4.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
INSTALLATION INSTRUCTIONS  
INSTALLATION  
3.10 Place the steel top onto the casing so that the 2 lugs on the  
4. FUEL BED ARRANGEMENT  
underside locate the top centrally within the casing. Place  
the cast iron grille into the recess in the centre of the top  
panel and locate the blanking plate into the grill (if  
required). See diagram 7.  
To access the ceramic fuel pieces, it will be necessary to  
remove the glass door. Lift off the decorative steel trim, see  
Diagram 8 and remove the 6 screws holding the glass  
frame. See Diagram 9.  
7
8
AR0882  
3.11 Check the pull of the flue system by applying a lighted  
smoke pellet to the flue system opening. If there is a  
definite flow into the chimney, proceed with the  
installation, if not; warm the chimney for a few minutes and  
repeat the test.  
9
IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY  
REQUIRE ATTENTION - SEEK EXPERT ADVICE.  
3.12 The flue system may now be connected to the stove, ensure  
that all joints are sealed with suitable fire resistant sealant. It  
is also recommended that a physical retention method may  
be used at the flue spigot joint, self-tapping screws being  
favoured.  
3.13 Connect a suitable pressure gauge to the test point located  
on the inlet fitting, and turn the gas supply on. Light the  
appliance and check all gas joints for possible leaks. Turn  
the appliance to maximum and check that the supply  
pressure is stated on the databadge. Turn the gas off and  
replace the test point screw, turn the gas on and check the  
test point for leaks.  
4.1 Place the flame baffle onto the shelf at the rear of the tray  
and push up against the rear ledge, see diagram 10.  
10  
AR0365  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
INSTALLATION INSTRUCTIONS  
INSTALLATION  
14  
4.2 Locate the front coal moulding in front of the flame baffle  
ensuring that the end legs sit flat against the burner skin, see  
diagram 11.  
11  
AR0369  
4.6 Ensure that the rope seal on the back of the glass frame is  
intact. Replace the glass frame ensuring that the 6 screws are  
tightened evenly. DO NOT OVERTIGHTEN. see diagram 15.  
AR0366  
15  
4.3 Place three large coals on the front coal so that they lean  
against the flame baffle, and the four large coals on the  
flame baffle so that they sit on the fingers, see diagram 12.  
12  
AR0887  
NEVER OPERATE THE STOVE WHEN THE DOOR IS  
REMOVED OR WHEN THE GLASS IS BROKEN.  
4.7 Secure the glass frame assembly using the 6 screws  
provided, tighten evenly and do not overtighten. See  
diagram 15.  
AR0367  
4.8 Hang the dcorative steel trim onto the glass frame as shown.  
See diagram 17  
4.4 Place two small coals at each end of the front coal so that  
they lean against the flame baffle, and a further two large  
coals on the flame baffle, one at each end, see diagram 13.  
17  
13  
AR0368  
5. LIGHTING  
4.5 Place five small coals along the rear of the flame baffle,  
resting against the rear ledge, see diagram 14.  
5.1  
Full instructions are given in Section 2.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
INSTALLATION INSTRUCTIONS  
COMMISSIONING  
1. COMMISSIONING  
1.1 Close all openable doors and windows in the room. Ignite  
the stove and operate on maximum for 10 minutes.  
Position a lighted smoke match just inside the draught  
diverter opening and check that all smoke is drawn into the  
opening. In restricted locations a mirror can be used. See  
diagram 1. If there is any doubt, run the stove for a further  
10 minutes, and repeat the test.  
1
1.2 If there are any extractor fans in adjacent rooms, the test  
must be repeated with the fans running on maximum and  
interconnecting doors open.  
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE  
AND SEEK EXPERT ADVICE.  
For future reference record the installation details on the  
Appliance Commissioning Checklist of these instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
SERVICING INSTRUCTIONS  
SERVICING / FAULT FINDING CHARTS  
1
1. SERVICING REQUIREMENTS  
This appliance must be serviced at least once a year by a  
competent person.  
All tests must be serviced by best practice as described by  
the current CORGI recommendations.  
Refer to ADVICE ON HANDLING AND DISPOSAL OF  
FIRE CERAMICS In User Instructions section 5  
1.1 Before any tests are undertaken on the appliance, conduct  
a gas soundness test for the property to ensure there  
are no gas leaks prior to starting work.  
1.2 Before any tests are undertaken on the appliance it is also  
recommended to fully check the operation of the  
appliance.  
1.3 Special checks  
1.3.1 Clean any lint or fluff from the pilot - pay particular  
attention to the aeration hole in the side of the pilot  
1.3.2 Clean away any fluff or lint from under the burner  
1.3.3 Check the spark gap on the pilot is correct  
1.4 Correct any faults found during the initial tests and then re-  
commission the appliance conducting the usual safety  
checks.  
1.5 Advise the customer of any remedial action taken.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
SERVICING INSTRUCTIONS  
FAULT FINDING CHARTS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
1. GENERAL  
3
1.1 All principal components can be replaced without removing  
the stove from its installation, although it will be necessary  
to remove the door and steel outer casing in order to access  
most components. In order to remove the casing, using the  
following procedure:  
1.2 Lift off the decorative steel trim see diagram 1 and remove  
the 6 screws holding the glass frame. See diagram 2.  
1
4
2
1.5 Lift the RH decorative panel to disengage from its locating  
brackets and remove from the stove, see diagram 4. It may  
not be necessary to remove the LH side.  
AR0887  
5
1.3 Carefully remove the top blanking plate and cast iron grille  
and place to one side, remove the steel top, see diagram  
16. If the unit has been connected to the top exit flue, it  
will be necessary to lift the support the grille and steep top  
whilst removing the outer steel casing.  
1.4 Remove the two front panels as shown. See diagrams 3 and  
4.  
AR0879  
AR0878  
1.6 This should allow full access to all major components.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
3
2. BURNER UNIT REMOVAL  
2.1 Turn the gas supply off at the isolation device. Ensure the  
unit is cool.  
A
Use cover material to front of appliance to protect  
paintwork etc.  
Remove the door and place to one side. (4 nuts).  
Carefully remove the ceramic fuel components to a safe  
place.  
Remove front cover-plate (2 screws).  
Remove cover plate fixing bracket (2 wing nuts).  
(Small Stoves only)  
Unscrew pilot union nut on gas valve. See diagram 1.  
AR0498  
2.4 Remove the 2 screws attaching burner to back of unit, see  
diagrams 4. Carefully withdraw burner unit upwards and tilt  
to remove the burner through door opening. Remove the 2  
screws holding the heat shield in place.  
1
Replace in reverse order checking all joints for leaks.  
4
Viewing slot on Marlborough only  
AR0391  
2.2 Disconnect thermocouple from gas valve. See diagram 2.  
Remove ignition lead from electrode. (Cut cable tie to  
ignition lead if required).  
AR0385  
2
3. PILOT UNIT  
3.1 Remove the burner module as described in Servicing  
Section 2 above. Carefully cut the cable ties holding the  
thermocouple to the pilot pipe. Remove the HT lead from  
the electrode, undo the two retaining screws and remove  
the pilot. See diagram 5.  
5
A
AR0943  
2.3 Loosen main injector nut on airbox and disconnect from  
injector, see diagram 3, A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
3.2 When replacing the pilot ensure the thermocouple follows  
8
its original route, i.e. along the pilot pipe. Attach the  
thermocouple to the pipe with new cable ties.  
3.3 Set the spark gap. See diagram 6.  
6
AR0916  
4.3 Replace with a new ignition lead following the same route  
as the old one. Replace the valve cover and the pilot  
assembly.  
4.4 Check operation of the new ignition lead.  
5. PIEZO  
5.1 The piezo assembly used on this appliance is not  
serviceable and is unlikely to fail.  
5.2 If a new piezo is required it will be necessary to change the  
gas valve. Refer to Section 6.  
4. IGNITION LEAD AND PIEZO  
6. GAS VALVE  
4.1 Gain access to the back of the pilot assembly, (see section  
2) and disconnect the ignition lead from the electrode.  
4.2 Remove the front cover from the control valve, (see  
diagrams 7 and 8). Disconnect the other end of the ignition  
lead from the valve body. Note the existing route of the  
ignition lead.  
6.1 Turn the gas supply off at the isolation device.  
6.2 Disconnect the 2x8mm and 1x4mm gas pipe fittings at the  
back of the gas valve and also disconnect the  
thermocouple, see diagram 9.  
9
7
AR0915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
6.3 Undo the single screw that secures the left-hand side of the  
control cover, see diagram 10.  
12  
10  
AR0915  
7.3 Reassemble the interrupter block and leads. Secure the  
thermocouple connection in the rear of the gas control. (Do  
not overtighten). Turn the gas supply on and check the  
entire pipework and valve joints for any leaks.  
6.4 To release the right-hand side of the control cover, insert  
the narrow blade screwdriver into the slot shown in diagram  
11. Lever it gently and pull from the right-hand side at the  
same time. The cover will now come off. There is a small  
cylindrical metal spacer inside the cover. This must be kept  
and replaced on the fixing screw during re-assembly.  
8. MAIN INJECTOR  
11  
8.1 Turn the gas supply off at the isolation device. Locate the  
main injector on the LH side of the airbox, undo the  
compression nut and pull the pipe clear of the injector  
body, see diagram 13,A.  
8.2 Rotate the injector until it is fully removed, and install the  
13  
A
AR0916  
6.5 Disconnect the ignition lead from the gas valve.  
6.6 Undo the two bolts securing the gas valve to the appliance  
and remove the valve.  
6.7 Replace in reverse order.  
6.8 Check all joints for gas leaks. Check operation of the  
thermocouple and ignition lead.  
AR0498  
7. MAGNETIC SAFETY VALVE  
correct replacement injector. Reassemble and turn the gas  
supply on, check for leaks.  
7.1 Turn the gas supply off at the isolation device. Undo the  
thermocouple connection from the back of the gas valve.  
Pull the sensor leads clear and remove the interrupter  
block.  
.
7.2 Undo the magnetic valve-retaining nut from the back of the  
control valve. Gently tap out the magnetic valve and replace  
with a new unit. Replace the retaining nut and tighten. See  
diagram 12.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
10.3 Remove the plate and replace with the correct size, ensure  
9. GAZCO FLUE SURE SYSTEM  
If the stove has been installed in a restrictive location, it  
may be necessary to remove the stove from its location.  
that the hole(s) in the plate align correctly with the holes in  
the underside of the airbox and replace the Nyloc nut.  
9.1 Locate the sensor in the draught diverter opening, and  
gently pull the two wires off the terminals. Undo the two  
taptite screws and remove the sensor and the two plastic  
spacers. See diagram 14.  
11. CHANGING BETWEEN GAS TYPES  
11.1 In order to change between gas types, it will be necessary  
to change the following items.  
14  
• Pilot Unit  
• Control Valve  
• Main Injector  
• Aeration Plate (if required)  
• Databadge  
The relevant parts can be ordered as a conventional kit  
from Gazco. Always quote the appliance type and serial  
number when ordering spare parts.  
** NOTE: THE CONTROL VALVE IS FACTORY PRESET  
FOR CORRECT GAS TYPE AND MODEL. A NEW UNIT  
WILL NEED TO BE ORDERED WHEN CHANGING  
BETWEEN GAS TYPES.  
9.2 Refit a new sensor ensuring the spacers are located between  
the sensor and the bracket. Replace the two leads.  
9.3 If it has been necessary to remove the stove, ensure that all  
disturbed gas joints are checked for gas soundness when  
reinstalled, and repeat the flue clearance test as detailed in  
the Commissioning Section.  
10. PRIMARY AERATION PLATE  
10.1 Turn the gas supply off at the isolation device.  
10.2 Locate the aeration plate on the underside of the airbox  
and remove the Nyloc nut, see diagram 15.  
15  
AR0381  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
12. CONTROL UPGRADE  
See Installation, section 1.  
13. SHORT SPARES LIST  
Components  
Steel Manhattan  
NG  
LPG  
Pilot Unit  
P10036  
IN0045  
ME1071  
P10037  
IN0006  
ME0834  
Injector  
Aeration Plate  
Gas Valve  
GC0088K*  
Flue Sensor  
Sensor Lead x 2  
Inerrupter  
EL0001  
EL0064  
GC0026  
GC0092  
GC0090  
-
Mag Unit  
Ignition Lead  
Rear Panel  
Flame Baffle  
Front Coal  
CE0120  
CE0124  
CE0136  
CE0116  
8455  
Coal Set  
Burner Skin  
Upgrade Kit Std  
Upgrade Kit Std Thermostatic  
8456  
* Set for Appliance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
SERVICE RECORDS  
2ND SERVICE  
1ST SERVICE  
Date of Service:...........................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
Date of Service:...........................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
4TH SERVICE  
3RD SERVICE  
Date of Service:...........................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
Date of Service:...........................................................................  
Next ServiceDue:........................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
6TH SERVICE  
5TH SERVICE  
Date ofService:............................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
Date of Service:...........................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
8TH SERVICE  
7TH SERVICE  
Date of Service:...........................................................................  
Next Due:...................................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
Date of Service:...........................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
10TH SERVICE  
9TH SERVICE  
Date of Service:...........................................................................  
Next Service Due:.......................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
Date of Service:...........................................................................  
Next Due:...................................................................................  
Signed:........................................................................................  
Dealer's Stamp/CORGI Registration Number  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG  
Tel: (01392) 261999 Fax: (01392) 444148 E-mail: [email protected]  
A member of the Stovax Group  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Stereo System XL 3000W User Manual
Sony Flat Panel Television 32CX520 User Manual
Sony Stereo System CDP CX350 User Manual
Standard Horizon Marine Radio GX3000S User Manual
Stanley Black Decker Automobile Parts CT06 User Manual
Sterling Plumbing Outdoor Shower 72270106 User Manual
Sun Microsystems Server X2250 User Manual
Sylvania Car Stereo System SMPS1018 User Manual
Sylvania Clock SA85016 User Manual
T Fal Fryer Family Pro Fryer User Manual