Stovax Indoor Fireplace 8050 User Manual

Brunel Mk III  
Conventional Flue  
With upgradeable control valve  
Instructions for Use,  
Installation and Servicing  
For use in GB, IE (Great Britain and Eire)  
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the  
translated instructions and in some cases the appliance will require modification. Contact Gazco for further information.  
IMPORTANT  
Do not attempt to burn rubbish in this fire. This stove must only be operated with the door secured firmly in position.  
The outer casing of this stove will become hot whilst in operation, it is therefore recommended that the appliance be  
guarded to protect the young and infirm using a suitable guard.  
Ensure that fabrics such as curtains are not positioned above or near to the stoves outer casing.  
Please read these Instructions carefully and keep them in a safe place.  
They will be needed when servicing the fire.  
The commissioning sheet found on page 3 should be completed by the installer.  
PR0595 Issue 4 (August 2008)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLIANCE COMMISSIONING CHECkLIST  
IMPORTANT NOTICE  
Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,  
as the information will be required when making any guaranteed claims.  
FLUE CHECk  
PASS  
FAIL  
1.  
2.  
3.  
Flue is correct for appliance  
Flue flow test  
Spillage test  
GAS CHECk  
1.  
2.  
3.  
Gas soundness & let by test  
Standing pressure test  
mb  
mb  
Appliance working pressure (on High Setting)  
NB All other gas appliances must be operating on full  
4.  
5.  
6.  
Gas rate  
m3/h  
Does ventilation meet appliance requirements  
Have controls been upgraded (Upgradeable models only)  
8455 Standard  
YES  
YES  
NO  
NO  
8456 Programmable Thermostatic and Timer  
DEALER AND INSTALLER INFORMATION  
Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Date of Purchase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Model No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Serial No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Gas Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Installation Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Engineer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Corgi Reg No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and  
your local Gazco dealer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance Commissioning  
Checklist is not fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid  
during the second year, to the extent permitted by law, if the annual service recommended in the Instructions for Use has been  
completed by a Corgi registered engineer, and a copy of the service visit report is available for inspection by a Gazco engineer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
USER INSTRUCTIONS  
2.3 • Hold in for 5 to 10 seconds and then release  
1. GENERAL  
The pilot remains lit. If the pilot does not light, repeat the  
procedure.  
1.1 A competent person must carry out installation and  
servicing.  
2
1.2 In all correspondence, please quote the appliance type and  
serial number, which can be found on the databadge  
located on a plate under the control valve.  
1.3 Ensure that curtains are not positioned above the appliance  
and there is at least 300mm between the sides of the  
appliance and any curtains.  
1.4 If any cracks appear in the glass panel do not use the  
appliance until the panel has been replaced.  
1.5 If, for any reason, the flue has to be removed from the  
appliance, the seals must be replaced in the inner spigot.  
1.7 Do not use a garden sprinkler or hose near the terminal.  
AR0396  
1.8 Do not stand or place objects on the terminal guard as this  
will deform it.  
1.9 This product is guaranteed for 2 years from the date of  
installation, as set out in the terms and conditions of sale  
between Gazco and your local Gazco dealer. Please consult  
with your local Gazco dealer if you have any questions. In  
all correspondence always quote the Model Number and  
Serial Number.  
1.10 Any combustible shelves or surrounding furniture must only  
be fitted in accordance with the minimum dimensions  
detailed in diagram 1.  
2.4 If the pilot still does not light after repeated attempts:  
• Contact the retailer or installer from whom the appliance  
was purchased.  
• Light the appliance by match as a temporary measure,  
see Section 4.  
2.5 The appliance can now be turned to the high position to  
ignite the main burner ( ), then controlled between high  
and low as desired.  
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE  
HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20  
MINUTES.  
1
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN  
USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO  
RE-LIGHT THE APPLIANCE.  
3. TURNING THE STOVE OFF  
3.1 • Hold in the control knob and turn clockwise until the  
knob is pointing at the off position ( ).  
4. LIGHTING THE STOVE WITH A MATCH  
AR0887  
4.1 • Slacken the domed nut on the upper door and loosen  
the bolt from behind the latch  
The door can now be opened.  
2. LIGHTING THE APPLIANCE  
2.1 • Ensure the control is pointing to the off position (( )  
Arrow A, Diagram 2).  
2.2 • Hold in the control knob and rotate anti-clockwise until a  
click is heard and the knob is pointing at the ignition  
symbol (( )Arrow B), the pilot should now be lit. See  
diagram 2.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
USER INSTRUCTIONS  
4.2 • Hold in the control knob and rotate anti-clockwise until  
5.2 • Remove the ceramic coals, rear panel, fuel bed and  
the knob is pointing at the ignition symbol ( )  
burner cover gasket  
• Apply a lighted match to the pilot hood, Diagram 3  
• Handle these components with care as they are fragile  
5.3 The ceramic coals and fuel bed can be cleaned using a  
vacuum cleaner with a soft brush attachment. It is advisable  
not to clean the cover gasket as this is very fragile.Ensure all  
debris is removed from the burner ports.  
3
5.4 • Replace the ceramics, referring to section 6.  
6. FUEL BED ARRANGEMENT  
6.1 • Place the white ceramic cover gasket onto the burner  
• Ensure the holes align with the burner ports, Diagram 4.  
4
AR0897  
4.3 When the pilot is lit:  
• Extinguish the match and continue to hold in the knob  
for 5 to 10 seconds  
4.4 • Close the door and tighten the bolt and nut with a  
spanner  
4.5 The fire can now be operated as previously described.  
5. CLEANING THE STOVE  
AR0898  
WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL  
IN A COLD CONDITION. THE STOVE RETAINS ITS HEAT FOR  
A CONSIDERABLE TIME AFTER SHUTDOWN.  
6.2 • Place the fuel bed over the burner, tallest part towards  
the rear of the firebox, Diagram 5  
ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS  
5
The fuel effect and side panels in this appliance are made  
from Refractory Ceramic Fibre (RCF), a material which is  
commonly used for this application.  
Protective clothing is not required when handling these  
articles, but we recommend you follow normal hygiene  
rules of not smoking, eating or drinking in the work area  
and always wash your hands before eating or drinking.  
To ensure that the release of RCF fibres are kept to a  
minimum, during installation and servicing a HEPA filtered  
vacuum is recommended to remove any dust accumulated  
in and around the appliance before and after working on it.  
When servicing the appliance it is recommended that the  
replaced items are not broken up, but are sealed within  
heavy duty polythene bags and labelled as RCF waste.  
AR0899  
RCF waste is classed as stable, non-reactive hazardous waste  
and may be disposed of at a licensed landfill site.  
Excessive exposure to these materials may cause temporary  
irritation to eyes, skin and respiratory tract; wash hands  
thoroughly after handling the material.  
6.3 • Carefully feed the rear panel into the firebox and engage  
it between the two locating brackets  
• Slide the panel down behind the fuel bed, Diagram 6  
5.1 • Release the door as described in section 4.1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
USER INSTRUCTIONS  
6.6 • Place the remaining four coals between the two rows of  
6
coals  
• Rotate the coals to ensure they are secure on the fuel  
bed, Diagram 9  
9
AR0900  
6.4 • Place three coals equally spaced on the rear of the fuel  
bed so they touch the rear panel, Diagram 7  
AR0903  
7
6.7 • Close the door and tighten the bolt and domed nut  
NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS  
DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT  
OF COALS, AS SPECIFIED IN THE DIAGRAMS  
7. GAzCO FLUE SURE SYSTEM  
7.1 The stove is fitted with the Gazco Flue Sure System, which  
will act to cut off the gas supply to the burners in the event  
of incorrect operation of the flue. If the system acts to cut  
off the gas supply, this indicates that there is insufficient flue  
pull. If this occurs a minimum of 10 minutes should be  
allowed before trying to relight. Continued operation of this  
safety device means there may be a serious problem with  
the flue system. A qualified gas engineer should inspect this.  
Do not use the stove until an engineer says it is safe to  
do so.  
AR0901  
6.5 • Place five coals on the front of the fuel bed so they rest  
on the front coal effect and lean against the vertical fingers,  
Diagram 8  
8
8. THE FLAME FAILURE DEVICE  
8.1 This is a safety feature incorporated in all GAZCO fires,  
which automatically switches off the gas supply if the pilot  
light goes out and fails to heat the thermocouple.  
AR0902  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
USER INSTRUCTIONS  
9. 'RUNNING IN'  
9.1 The surface coating on your GAZCO stove will ‘burn off’  
during the first 24 hours of operation on high, producing a  
harmless and temporary odour. If the odour persists ask  
your retail for advice.  
10. SERVICING  
10.1 A qualified gas engineer must service the stove every 12  
months. In all correspondence, always quote the appliance  
type and the serial number that may be found on the data  
badge on the appliance.  
11. VENTILATION  
11.1 Any purpose provided ventilation should be checked  
periodically to ensure that it is free from obstruction.  
12. INSTALLATION DETAILS  
12.1 To assist in any future correspondence, your installer should  
have completed this commissioning sheet, this records the  
essential installation details of this appliance. In all  
correspondence always quote the model No. and serial No.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
INSTALLATION INSTRUCTIONS  
TECHNICAL SPECIFICATION  
Covering the following models Brunel - 8050 - P8050  
Model  
Gas Gas Type  
Cat.  
Pressure  
Nox  
Class  
Aeration  
Injector  
Gas Rate  
m 3/h  
Input kW  
(Gros)  
Country  
Hoog Laag  
I2H  
Brunel 8050  
Natural Gas (G20)  
20mbar  
29 mbar  
37 mbar  
5
5
4 x 16  
16 x 23 (2)  
16 x 23  
120  
260  
0.43  
0.127  
0.167  
4.5  
2.25  
2
GB, IE  
GB, IE  
Butane (G30)  
Propane (G31)  
I3+  
4.45  
Brunel P8050  
Efficiency Class II  
Gas inlaat afmeting 8mm Ø  
Minimum flue specification T260/N2/O/D/1  
Maximum flue temperature 180°C  
AR0889  
AR0887  
AR0888  
AR0521  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
INSTALLATION INSTRUCTIONS  
SITE REQUIREMENTS  
4. APPLIANCE LOCATION  
1. FLUE AND CHIMNEY REQUIREMENTS  
4.1 This appliance must stand on a non-combustible hearth that  
is at least 12mm thick, and project a minimum of 50mm  
from the base of the stove in all directions.  
1.1 The chimney or flue system must comply with the rules in  
force, and must be a minimum of 127mm (5”) in diameter.  
The following are suitable for use with this  
A) 230mm x 230mm (9” x 9”) conventional brick or stone  
built chimney.  
appliance.  
1
B) A precast flue system used in conjunction with vertical  
closure plate and flue spigot extention.  
C) A metal flue box used in conjunction with a vertical  
closure plate and flue spigot extention. The metal flue box  
must be constructed to the requirements of BS 715.  
NOTE: IF IT IS INTENDED TO FIT THE STOVE INTO AN  
EXISTING BRICK CHIMNEY WITHOUT A CLOSURE  
PLATE, A 127MM LINER MUST BE USED.  
AR0035  
1.2 The minimum effect height of the flue or chimney must be  
3 metres (10ft).  
4.2 This appliance must not be installed in a room that contains  
a bath or shower.  
1.3 The chimney or flue must be free from any obstruction. Any  
damper plates should be removed or secured in the fully  
open position, and no restrictor plates should be fitted.  
4.3 The stove is not suitable for installation against a  
combustible wall; all combustible materials must be  
removed from the area behind the stove.  
1.4 The chimney should be swept immediately prior to the  
installation of the appliance. However, where it can be  
seen that the chimney is clean and unobstructed throughout  
its entire length, it need not be swept.  
4.4 Ensure that all minimum clearances to combusible materials  
are complied with, Diagrams 2 & 2A.  
2
2. VENTILATION  
2.1 This appliance has a nominal input not exceeding 7.0kw  
and therefore, does not normally require any additional  
premanent ventilation.  
2.2 If however, spillage is detected when commissioning the  
appliance, there may be insufficient natural ventilation and  
additional ventilation may be required.  
2.3 For ventilation requirements it will be necessary to refer to  
national and local rules in force.  
AR0884  
2A  
3. INSTALLATION OF THE GAS SUPPLY  
3.1 Before installation, ensure that the local distribution  
conditions (identification of the type of gas and pressure)  
and the adjustment of the appliance are compatible.  
3.2 Ensure that the gas supply is capable of delivering the  
required amount of gas, and is in accordance with the rules  
in force.  
3.3 Soft copper tubing and soft soldered joints can be used but  
must not be closer than 50mm to the base of the tray.  
AR0885  
3.4 A means of isolating the gas supply to the appliance must  
be provided independent of any appliance control.  
3.5 All supply gas pipes must be purged of any debris that may  
have entered, prior to connection to the appliance.  
In a non-combustible recess attention must be given to  
allowing adequate clearance at the sides and rear of the  
stove, so that a spillage test can be performed, and the  
controls reached.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
INSTALLATION INSTRUCTIONS  
INSTALLATION  
2.3 Having run the gas supply to the stove, PURGE THE  
IMPORTANT: ENSURE THAT THE APPLIANCE IS  
CORRECTLY ADJUSTED FOR THE GAS TYPE AND  
CATEGORY APPLICABLE IN THE COUNTRY OF USE.  
REFER TO DATABADGE AND TECHNICAL  
SUPPLY PIPE, this is essential to expel any debris that may  
block the gas controls.  
• Connect the gas supply to the 8mm-compression elbow  
at the RH rear corner of the stove, Diagram 3.  
SPECIFICATIONS AT THE FRONT OF THE BOOkLET.  
LPG MODELS: THE APPLIANCE IS FACTORY SET TO  
RUN ON BUTANE G30. IF IT IS INTENDED TO BE USED  
ON PROPANE G31 THE AERATION PLATE SUPPLIED  
MUST BE FITTED.  
3
FOR DETAILS OF CHANGING AERATION PLATES REFER  
TO SECTION 29.  
FOR DETAILS OF CHANGING BETWEEN GAS TYPES  
REFER TO SECTION 30.  
1. SAFETY PRECAUTIONS  
1.1 This appliance must be installed in accordance with the  
rules in force, and used only in a sufficiently ventilated  
space. Place read these instructions before installation and  
use of this appliance.  
AR0396  
1.2 All the instructions must be left intact with the user.  
2.4 • Check the pull of the flue system by applying a lighted  
1.3 In your own interest, and those of safety, this appliance  
must be installed by a competent person in accordance  
with local and national codes of practice. Failure to install  
the appliance correctly could lead to prosecution.  
smoke pellet to the flue system opening.  
If there is a definite flow into the chimney, proceed with  
the installation, if not warm the chimney for a few minutes.  
1.4 This appliance is intended for use on a governed gas  
installation and set to the required pressure.  
IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY  
REQUIRE ATTENTION - SEEk EXPERT ADVICE  
1.5 Keep all plastic bags away from young children.  
2.5 The flue system may now be connected to the stove:  
1.6 Do not place any object on or near to the stove. Allow  
adequate clearance above the stove, see Technical  
Specification.  
• Ensure that all joints are sealed with a suitable fire  
resistant sealant.  
It is also recommended that a physical retention method be  
used at the flue spigot joint, self-tapping screws being  
favoured.  
1.7 The stove is fitted with the Gazco Flue Sure System, which  
will act to cut off the gas supply to the appliance in the  
event of incorrect operation of the flue. If the system acts to  
shut off the gas supply, this indicates that there is insufficient  
flue pull. If this occurs a minimum of 10 minutes should be  
allowed before trying to relight. Continued operation of this  
safety device means that there may be a serious problem  
with the flue system; a qualified gas engineer should inspect  
this. DO NOT USE THE STOVE UNTIL AN ENGINEER  
SAYS IT IS SAFE TO DO SO.  
2.6 • Connect a suitable pressure gauge to the test point  
located on the inlet fitting,  
• Turn the gas supply on  
• Light the appliance and check all gas joints for possible  
leaks  
• Turn the appliance to a maximum and check that the  
supply pressure is as stated on the databadge.  
1.8 The Flue Sure System must not be tampered with. Use only  
genuine Gazco replacement parts when servicing the system  
- refer to servicing section on page 15.  
• Turn the gas off and replace the test point screw  
• Turn the gas on and check the test point for leaks.  
NOTE: The stove is also suitable for installation onto a  
fireplace opening. The following method illustrates how this  
can be achieved with the aid of the optional closure plate  
and spigot extension:  
2. INSTALLATION OF THE STOVE  
• Ensure that the fireplace dimensions are shown in  
Diagram 4.  
2.1 • Remove the outer carton  
• Take the stove off the pallet and remove the accessory  
carton.  
2.2 • Position the stove ensuring all appropriate clearances are  
observed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
0
INSTALLATION INSTRUCTIONS  
INSTALLATION  
3.2 • Place the fuel bed over the burner, tallest part towards  
the rear of the firebox, Diagram 6  
4
6
AR0886  
AR0899  
2.7 • Place the closure plate against the fireplace opening •  
• Ensure there is sufficient overlap around the perimeter to  
allow a fume tight seal to be made  
3.3 • Carefully feed the rear panel into the firebox and engage  
• Cut straight across the top of the plate if trimming is  
required  
it between the two locating brackets  
• Slide the panel down behind the fuel bed, Diagram 7  
2.8 • Seal the plate to the opening and the hearth with suitable  
heat resisting material.  
7
2.9 • Secure the spigot extension to the engine assembly and  
seal with heat resisting tape or similar  
• Position the engine assembly ensuring the 50mm rear  
clearance is maintained  
• Proceed with the installation as detailed in points 2.2 to  
2.6 above.  
2.10 • Secure the lip plate to the underside of the stove with  
the two bolts provided.  
3. FUELBED ARRANGEMENT  
AR0900  
3.1 • Place the white ceramic cover gasket onto the burner  
• Ensure the holes align with the burner ports, Diagram 5.  
3.4 • Place three coals equally spaced on the rear of the fuel  
bed so they touch the rear panel, Diagram 8  
5
8
AR0898  
AR0901  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
INSTALLATION INSTRUCTIONS  
INSTALLATION  
3.5 • Place five coals on the front of the fuel bed so they rest  
on the front coal effect and lean against the vertical fingers,  
Diagram 9  
9
AR0902  
3.6 • Place the remaining four coals between the two rows of  
coals  
• Rotate the coals to ensure they are secure on the fuel  
bed, Diagram 10  
10  
AR0903  
3.7 • Close the door and tighten the bolt and domed nut  
NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS  
DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT  
OF COALS, AS SPECIFIED IN THE DIAGRAMS  
4. LIGHTING  
4.1 Full instructions are given in the User Section of this manual  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
COMMISSIONING  
1. COMMISSIONING  
1.1 • Close all openable doors and windows in the room  
• Ignite the stove and operate on maximum for 10 minutes  
1
AR0539  
If there is any doubt, run the stove for a further 10 minutes,  
and repeat the test.  
1.2 If there are any extractor fans in adjacent rooms, the test  
must be repeated with the fans running on maximum and  
interconnecting doors open.  
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE  
AND SEEk EXPERT ADVICE.  
For future reference record the installation details on the  
Commissioning Sheet page 3 of these instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
SERVICING INSTRUCTIONS  
SERVICING / FAULT FINDING CHARTS  
3.5mm  
1. SERVICING REQUIREMENTS  
This appliance must be serviced at least once a year by a  
competent person.  
All tests must be serviced by best practice as described by  
the current CORGI recommendations.  
1.1 Before any test are undertaken on the appliance, conduct a  
gas soundness test for the property to ensure that there are  
no gas leaks prior to starting work.  
1.2 Before any tests are undertaken on the applaince it is also  
recommended to fully check the operation of the appliance.  
1.3 Special checks  
1.3.1 Clean any lint or fluff from the pilot - pay particular  
attention to the aeration hole in the side of the pilot  
AR0097  
1.3.2 Clean away any fluff or lint from under the burner  
1.3.3 Check that the spark gap on the pilot is correct  
1.4 Correct any faults found during the initial tests and then  
re-commission the appliance conducting the usual safety  
checks.  
1.5 Advise the customer of any remedial action taken.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
SERVICING INSTRUCTIONS  
FAULT FINDING CHARTS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
3. IGNITION LEAD AND PIEzO  
1. GENERAL  
1.1 This appliance must be serviced at least once a year by a  
competent person.  
Due to the method of manufacture, these components can  
only be replaced as an integral unit.  
1.2 All principal components can be replaced without removing  
the stove from its installation, although it is essential that the  
gas supply to the appliance is turned off at the isolation  
device before proceeding further.  
3.1 • Turn the gas supply off at the isolation device  
• Pull the control knob off the gas valve spindle to reveal  
the piezo securing screw access holes  
Using a small pozidriv screwdriver:  
• Remove the two screws, Diagram 2  
2. PILOT UNIT  
2
2.1 • Turn the gas supply off at the isolation device.  
To open the doors:  
• Slacken the domed nut on the upper door and loosen  
the bolt from behind the latch  
2.2 • Undo the pilot compression nut  
• Remove the ignition lead from the electrode by gently  
pulling downwards  
• Undo the thermocouple from the back of the gas valve,  
Diagram 1,D  
1
AR0894  
3.2 • Pull the piezo body down and remove from the valve  
• Disconnect the ignition lead from the electrode, Diagram  
1,D  
3.3 • Replace the assembly with a new unit  
• Refit the screws and connect the ignition lead to the  
electrode  
• Check the operation of the new piezo  
• Turn the gas supply on and with the pilot running:  
• Check for leaks, especially where the two halves of the  
valve join  
AR0895  
• Replace the control knob  
NOTE: WHILST PERFORMING THE PIEzO  
REPLACEMENT, YOU WILL BE BREAkING THE SEAL  
BETWEEN THE TOP AND BOTTOM HALVES OF THE  
VALVE. ENSURE THAT THIS JOINT IS CORRECTLY  
SECURED AND LEAk TESTED.  
2.3 • Remove the two screws securing the pilot unit  
• Cut the cable tie securing the ignition lead taking care  
not to damage it  
The unit can now be removed from beneath the stove.  
2.4 When replacing the new pilot unit:  
• Ensure the thermocouple follows the same route as the  
original one  
4. GAS FILTER  
• Secure the ignition lead to the pilot pipe with a new  
cable tie  
The gas filter is located just inside the inlet boss of the  
control valve, to replace the filter, proceed as follows:  
4.1 • Turn the gas supply off at the isolation device  
2.5 • Reconnect the thermocouple, ignition lead and pipe  
• Turn on the gas supply and check for leaks  
• Close the doors and tighten the bolts and locknuts  
• Undo the inlet compression nut and pull the pipe clear  
of the valve, Diagam 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
3
4
AR0320  
AR0895  
• Prise the small retaining ring out of the inlet and remove  
the filter  
4.2 • Replace with a new filter and push into position ensuring  
6.2 • Rotate the injector until it can be fully removed  
• Replace with a new component  
• Reassemble the pipe work and check for leaks.  
6.3 • Close the doors and tighten the bolts and lock nut  
that it sits on the shoulder  
• Replace the retaining ring and push into position.  
4.3 • Replace the inlet pipe, turn the gas supply on and check  
for leaks  
7. GAzCO FLUE SURE SYSTEM  
If the stove has been installed in a restricted location, it may  
be necessary to remove the stove from its location.  
5. MAGNETIC SAFETY VALVE  
7.1 • Find the sensor in the draught diverter opening and  
5.1 • Turn the gas supply off at the isolation device  
gently pull the two wires off the terminals  
• Undo the thermocouple connection from the back of the  
gas valve  
• Pull the sensor leads clear and remove the interrupter  
block  
• Undo the two taptite screws and remove the sensor and  
the two plastic spacers, Diagram 5  
5
5.2 • Undo the mag valve-retaining nut from the back of the  
control valve, gently tap out the mag valve and replace with  
a new unit  
• Replace the retaining nut and tighten, Diagram 3  
5.3 • Reassemble the interrupter block and leads  
• Secure in place with the thermocouple  
• Turn the gas supply on and check the entire pipework  
and valve joints for any leaks  
6. MAIN INJECTOR  
6.1 • Turn the gas supply off at the isolation device  
To open the doors:  
• Slacken the domed nut on the upper door and loosen  
the bolt from behind the latch  
The injector is located on the right hand side of the burner.  
• Undo the injector nut and gas valve nut  
7.2 Refit a new sensor ensuring that the spacers are located  
between the sensor and the bracket, replace the two leads.  
7.3 If it has been necessary to remove the stove, ensure that all  
disturbed gas joints are leak tested when reinstalled, and  
repeat the flue clearance test as detailed in section 21.  
• Remove the feed pipe, Diagram4, A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
SERVICING INSTRUCTIONS  
REPLACING PARTS  
8. PRIMARY AERATION PLATE  
9. CHANGING BETWEEN GAS TYPES  
8.1 • Turn the gas supply off at the isolation device.  
8.2 To open the doors:  
In order to change between gas types, it will be necessary to  
change the following items:  
Burner Unit  
Pilot Unit  
• Slacken the domed nut on the upper door and loosen  
the bolt from behind the latch  
8.3 • Remove the two screws securing the pilot unit and undo  
Control Valve  
Injector  
the injector nut, Diagam 6,B  
Aeration Plate  
Databadge  
6
The relevant parts can be ordered from the parts list, always  
quote the appliance type and serial number when ordering  
spare parts.  
*NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR  
CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL  
NEED TO BE ORDERED WHEN CHANGING BETWEEN  
GAS TYPES.  
10. SHORT SPAES LIST  
APPLIANCE  
8050  
NG  
P8050  
LPG  
AR0895  
• Remove the four fixing screws and withdraw the burner  
unit, Diagram 6,C  
COMPONENT  
GZ3279  
PI0047  
IN0001  
GZ3278  
PI0048  
IN0003  
8.4 The aeration plate is located on the rear of the venturi: •  
• Remove the fixing screw and replace with the correct  
plate  
BURNER UNIT  
PILOT UNIT  
INJECTOR  
When replacing the plate:  
• Ensure the lower edge is hooked over the flange of the  
venturi., Diagram 7,  
G20  
GZ3269(C)  
G30 N/A  
AERATION PLATE  
G25  
GZ3270(D)  
G31  
GZ2003(A)  
7
GAS VALVE  
GC0056*  
FLUE SENSOR  
SENSOR LEAD  
INTERRUPTOR  
MAG UNIT  
EL0001  
EL0064  
GC0026  
GC0016  
GC0062  
GC0065  
PIEZO/IGN. UNIT  
GAS FILTER  
BURNER COVER  
REAR PANEL  
FUEL BED  
CE0358  
CE0359  
AR0766  
CE0357  
CE0356  
CE0284  
PR0397  
8.5 • Replace the burner, ceramic components and check for  
leaks  
COAL SET  
• Close the doors and lock the bolts and nuts  
DATA BADGE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
SERVICE RECORDS  
1ST SERVICE  
2ND SERVICE  
Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
Date of Service:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
3RD SERVICE  
4TH SERVICE  
Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
Date of Service:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
5TH SERVICE  
6TH SERVICE  
Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
Date of Service:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
7TH SERVICE  
8TH SERVICE  
Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
Date of Service:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
9TH SERVICE  
10TH SERVICE  
Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
Date of Service:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Next Service due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dealer’s Stamp/CORGI Registration Number  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG  
Tel: (01392) 261999 Fax: (01392) 444148 E-mail: [email protected]  
A member of the Stovax Group  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp CRT Television LC 37HV4M User Manual
Shure Microphone MX400D User Manual
Sony Projection Television KP FX43 User Manual
Southbend Lathe SB1231 User Manual
Speco Technologies Security Camera HT7715DNV User Manual
Structured Cable Products Speaker apple User Manual
Sylvania Portable DVD Player SDVD9020 User Manual
Symphonic CRT Television ST420FF User Manual
TAG Server SV 2000 X2 User Manual
Tanaka Chainsaw ECS 351 User Manual