Sterling Dehumidifier SDAA 25 100 User Manual

SDAA 25-100 (15-60 cfm)  
Dehumidifying Dryers  
Part Number: 882.00290.00  
Bulletin Number: DH1-640  
Effective: 12/06/05  
Write Down Your Serial Numbers Here For Future Reference:  
_________________________  
_________________________  
_________________________  
_________________________  
_________________________  
_________________________  
We are committed to a continuing program of product improvement.  
Specifications, appearance, and dimensions described in this manual are subject to change without notice.  
DCN No. ____________  
© Copyright 2005  
All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
CHAPTER 1: SAFETY................................................................V  
1-1  
How to Use This Manual ............................................................................................. v  
Safety Symbols Used in this Manual.....................................................................v  
Warnings and Precautions ......................................................................................... vi  
Responsibility .............................................................................................................vii  
General Responsibility......................................................................................... vii  
Operator Responsibility.......................................................................................viii  
Maintenance Responsibility.................................................................................. ix  
Reporting a Safety Defect .................................................................................... ix  
1-2  
1-3  
CHAPTER 2: FUNCTIONAL DESCRIPTION...........................11  
2-1  
2-2  
Models Covered in This Manual................................................................................11  
General Description...................................................................................................11  
What is desiccant? ..............................................................................................12  
The Process/Regeneration Cycle........................................................................12  
Standard Features.....................................................................................................12  
Mechanical Features...........................................................................................12  
Electrical Features...............................................................................................12  
Controller Features..............................................................................................13  
Options......................................................................................................................13  
Safety Devices and Interlocks...................................................................................13  
2-3  
2-4  
2-5  
CHAPTER 3: INSTALLATION..................................................15  
3-1  
3-2  
Uncrating the Equipment...........................................................................................15  
Rigging and Placing the Dryer...................................................................................15  
Recommended Dryer Lifting Hardware ...............................................................18  
Electrical Connections...............................................................................................19  
Setup Procedures......................................................................................................20  
Checking for Proper Blower Rotation ..................................................................20  
Making Dryer/Drying Hopper Process Air Connections.......................................20  
Drying Hopper Air Trap Considerations...............................................................21  
Optional Aftercooler.............................................................................................21  
Initial Start-up ............................................................................................................22  
Pre-Startup Checks.............................................................................................22  
Starting Up the Dryer...........................................................................................22  
Auto-Tuning the Dryer.........................................................................................22  
Shutting Down the Dryer .....................................................................................23  
3-3  
3-4  
3-5  
CHAPTER 4: OPERATION.......................................................24  
4-1  
4-2  
Start-up......................................................................................................................24  
Controller Description and Operation........................................................................25  
Identifying Control Panel Indicator Lights and Switches for the Standard  
Controller.............................................................................................................25  
Process Air Temperature Controller....................................................................26  
Setting the Process Air Temperature ..................................................................27  
Dehumidifying Dryers  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Restoring the Process Air Temperature Controller (E5CN) to Factory Settings..28  
Process Air Dew Point Display............................................................................31  
Setting the High Dew Point Alarm .......................................................................31  
Restoring the Process Air Dew Point Meter (E5CK) to Factory Setup................31  
Redundant Safety Controller Display ..................................................................32  
Setting the Redundant Safety Controller.............................................................32  
Restoring the WATLOW Redundant Safety Controller to Factory Setup ............32  
Dryer Operation Procedures .....................................................................................34  
Controller Operation (Without Optional Alarm Horn & Reset Button).................34  
Controller Operation (With Optional Alarm Horn & Reset Button).......................37  
Alarm Display Messages.....................................................................................39  
Auto-Tuning the Dryer...............................................................................................40  
Shutting Down the Dryer ...........................................................................................40  
4-3  
4-4  
4-5  
CHAPTER 5: MAINTENANCE .................................................41  
5-1  
5-2  
Preventative Maintenance Schedule.........................................................................41  
Preventative Maintenance.........................................................................................42  
Servicing Process Air Filters................................................................................42  
Servicing the Dew Point Monitor .........................................................................43  
Corrective Maintenance ............................................................................................44  
Symptoms of Worn Desiccant.............................................................................44  
Replacing Worn Desiccant..................................................................................45  
Replacing the Process Heater.............................................................................47  
5-3  
CHAPTER 6: TROUBLESHOOTING .......................................48  
6-1  
6-2  
Introduction................................................................................................................48  
Determining Temperature Controller Errors or Sensor Errors...................................51  
Using a Thermocouple ........................................................................................51  
Using a Platinum Resistance Thermometer........................................................51  
CHAPTER 7: APPENDIX..........................................................52  
7-1  
Warranty....................................................................................................................52  
Warranty Specifications.......................................................................................52  
Warranty Restrictions..........................................................................................52  
Warranty Liabilities..............................................................................................53  
Customer Responsibilities...................................................................................53  
Optional Components................................................................................................53  
Technical Specifications............................................................................................54  
Annex B Information............................................................................................54  
Aftercooler Design Specifications........................................................................55  
Drawings and Diagrams............................................................................................55  
Spare Parts List.........................................................................................................55  
Returned Material Policy ...........................................................................................57  
Credit Returns .....................................................................................................57  
Warranty Returns ................................................................................................57  
Safety Tag Information..............................................................................................57  
Dryer Safety Tags ...............................................................................................57  
Dryer Identification (Serial Number) Tag...................................................................58  
Technical Assistance.................................................................................................59  
Parts Department ................................................................................................59  
7-2  
7-3  
7-4  
7-5  
7-6  
7-7  
7-8  
7-9  
Dehumidifying Dryers  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Department.............................................................................................59  
Sales Department................................................................................................59  
Contract Department...........................................................................................59  
Dehumidifying Dryers  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Safety  
1-1 How to Use This Manual  
Use this manual as a guide and reference for installing, operating, and maintaining your  
dehumidifying dryer. The purpose is to assist you in applying efficient, proven techniques  
that enhance equipment productivity.  
This manual covers only light corrective maintenance. No other maintenance should be  
undertaken without first contacting a service engineer.  
The Functional Description section outlines models covered, standard features, and safety  
features. Additional sections within the manual provide instructions for installation, pre-  
operational procedures, operation, preventive maintenance, and corrective maintenance.  
The Installation chapter includes required data for receiving, unpacking, inspecting, and setup  
of the dehumidifying dryer. We can also provide the assistance of a factory-trained technician  
to help train your operator(s) for a nominal charge. This section includes instructions, checks,  
and adjustments that should be followed before commencing with operation of the  
dehumidifying dryer. These instructions are intended to supplement standard shop  
procedures performed at shift, daily, and weekly intervals.  
The Operation chapter includes a description of electrical and mechanical controls, in  
addition to information for operating the dryer safely and efficiently.  
The Maintenance chapter is intended to serve as a source of detailed assembly and  
disassembly instructions for those areas of the equipment requiring service. Preventive  
maintenance sections are included to ensure that your dehumidifying dryer provides  
excellent, long service.  
The Troubleshooting chapter serves as a guide for identification of most common problems.  
Potential problems are listed, along with possible causes and related solutions.  
The Appendix contains technical specifications, drawings, schematics, parts lists, and  
available options. A spare parts list with part numbers specific to your machine is provided  
with your shipping paperwork package. Refer to this section for a listing of spare parts for  
purchase. Have your serial number and model number ready when ordering.  
Safety Symbols Used in this Manual  
The following safety alert symbols are used to alert you to potential personal injury hazards.  
Obey all safety messages that follow these symbols to avoid possible injury or death.  
DANGER! DANGER indicates an imminently hazardous situation that, if not avoided,  
will result in death or serious injury.  
WARNING! WARNING indicates a potentially hazardous situation or practice that, if  
not avoided, could result in death or serious injury.  
Caution!  
CAUTION indicates a potentially hazardous situation or practice that, if  
not avoided, may result in minor or moderate injury or in property damage.  
Dehumidifying Dryers  
Chapter 1: Safety  
v of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-2 Warnings and Precautions  
Our equipment is designed to provide safe and reliable operation when installed and operated  
within design specifications, following national and local safety codes. This may include, but  
is not limited to OSHA, NEC, CSA, SPI, and any other local, national and international  
regulations.  
To avoid possible personal injury or equipment damage when installing, operating, or  
maintaining this equipment, use good judgment and follow these safe practices:  
; Read and follow these operation and installation instructions when installing,  
operating, and maintaining this equipment. If these instructions become  
damaged or unreadable, additional copies are available from the manufacturer.  
; Follow all SAFETY CODES.  
; Wear SAFETY GLASSES and WORK GLOVES.  
; Work only with approved tools and devices.  
; Disconnect and/or lock out power before servicing or maintaining the equipment.  
; Use care when LOADING, UNLOADING, RIGGING, or MOVING this  
equipment.  
; Operate this equipment within design specifications.  
; OPEN, TAG, and LOCK ALL DISCONNECTS before working on equipment.  
You should remove the fuses and carry them with you.  
; Make sure the equipment and components are properly GROUNDED before you  
switch on power.  
; Use EXTEREME CAUTION when working with dryer. HIGH HEAT can be  
dangerous. Keep body parts, tools, clothing, and debris away from dryer.  
; When welding or brazing in or around this equipment, make sure VENTILATION is  
ADEQUATE. PROTECT adjacent materials from flame or sparks by shielding with  
sheet metal. An approved FIRE EXTINGUISHER should be close at hand and  
ready for use if needed.  
; Do not restore power until you remove all tools, test equipment, etc., and the  
equipment and related components are fully reassembled.  
; Only PROPERLY TRAINED personnel familiar with the information in this  
manual should work on this equipment.  
We have long recognized the importance of safety and have designed and manufactured our  
equipment with operator safety as a prime consideration. We expect you, as a user, to abide  
by the foregoing recommendations in order to make operator safety a reality.  
Dehumidifying Dryers  
Chapter 1: Safety  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3 Responsibility  
These machines are constructed for maximum operator safety when used under standard  
operating conditions and when recommended instructions are followed in the maintenance  
and operation of the machine.  
All personnel engaged in the use of the machine should become familiar with its operation as  
described in this manual.  
Proper operation of the machine promotes safety for the operator and all workers in its  
vicinity.  
Each individual must take responsibility for observing the prescribed safety rules as outlined.  
All warning and danger signs must be observed and obeyed. All actual or potential danger  
areas must be reported to your immediate supervisor.  
General Responsibility  
No mater who you are, safety is important. Owners, operators and maintenance personnel  
must realize that every day, safety is a vital part of their jobs.  
If your main concern is loss of productivity, remember that production is always affected in a  
negative way following an accident. The following are some of the ways that accidents can  
affect your production:  
Loss of a skilled operator (temporarily or permanently)  
Breakdown of shop morale  
Costly damage to equipment  
Downtime  
An effective safety program is responsible and economically sound.  
Organize a safety committee or group, and hold regular meetings. Promote this group from  
the management level. Through this group, the safety program can be continually reviewed,  
maintained, and improved. Keep minutes or a record of the meetings.  
Hold daily equipment inspections in addition to regular maintenance checks. You will keep  
your equipment safe for production and exhibit your commitment to safety.  
Please read and use this manual as a guide to equipment safety. This manual contains safety  
warnings throughout, specific to each function and point of operation.  
Dehumidifying Dryers  
Chapter 1: Safety  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operator Responsibility  
The operator’s responsibility does not end with efficient production. The operator usually has  
the most daily contact with the equipment and intimately knows its capabilities and  
limitations.  
Plant and personnel safety is sometimes forgotten in the desire to meet incentive rates, or  
through a casual attitude toward machinery formed over a period of months or years. Your  
employer probably has established a set of safety rules in your workplace. Those rules, this  
manual, or any other safety information will not keep you from being injured while operating  
your equipment.  
Learn and always use safe operation. Cooperate with co-workers to promote safe practices.  
Immediately report any potentially dangerous situation to your supervisor or appropriate  
person.  
REMEMBER:  
NEVER place your hands or any part of your body in any dangerous location.  
NEVER operate, service, or adjust the dryer without appropriate training and first  
reading and understanding this manual.  
NEVER try to pull material out of the dryer with your hands while it is running!  
Before you start the dryer check the following:  
Remove all tools from the dryer;  
Be sure no objects (tools, nuts, bolts, clamps, bars) are laying in the  
hopper area;  
If your dryer has been inoperative or unattended, check all settings before starting the  
unit.  
At the beginning of your shift and after breaks, verify that the controls and other  
auxiliary equipment are functioning properly.  
Keep all safety guards in place and in good repair. NEVER attempt to bypass, modify,  
or remove safety guards. Such alteration is not only unsafe, but will void the warranty  
on your equipment.  
When changing control settings to perform a different mode of operation, be sure  
selector switches are correctly positioned. Locking selector switches should only be  
adjusted by authorized personnel and the keys removed after setting.  
Report the following occurrences IMMEDIATELY:  
unsafe operation or condition  
unusual dryer action  
leakage  
improper maintenance  
NEVER stand or sit where you could slip or stumble into the dryer  
while working on it.  
DO NOT wear loose clothing or jewelry, which can be caught while working on a  
dryer. In addition, cover or tie back long hair.  
Dehumidifying Dryers  
Chapter 1: Safety  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clean the dryer and surrounding area DAILY, and inspect the machine for loose,  
missing or broken parts.  
Shut off power to the dryer when it is not in use. Turn the switch to the OFF position,  
or unplug it from the power source.  
Maintenance Responsibility  
Proper maintenance is essential to safety. If you are a maintenance worker, you must make  
safety a priority to effectively repair and maintain equipment.  
Before removing, adjusting, or replacing parts on a machine, remember to turn off all electric  
supplies and all accessory equipment at the machine, and disconnect and lockout electrical  
power. Attach warning tags to the disconnect switch.  
When you need to perform maintenance or repair work on a dryer above floor level, use a  
solid platform or a hydraulic elevator. If there is a permanently installed catwalk on your  
dryer, use it. The work platform should have secure footing and a place for tools and parts.  
DO NOT climb on dryers, machines, or work from ladders.  
If you need to repair a large component, use appropriate handling equipment. Before you use  
handling equipment (portable “A” frames, electric boom trucks, fork trucks, overhead cranes)  
be sure the load does not exceed the capacity of the handling equipment or cause it to become  
unstable.  
Carefully test the condition of lifting cables, chains, ropes, slings, and hooks before using  
them to lift a load.  
Be sure that all non-current carrying parts are correctly connected to earth ground with an  
electrical conductor that complies with current codes. Install in accordance with national and  
local codes.  
When you have completed the repair or maintenance procedure, check your work and remove  
your tools, rigging, and handling equipment.  
Do not restore power to the dryer until all persons are clear of the area. DO NOT start and  
run the dryer until you are sure all parts are functioning correctly.  
BEFORE you turn the dryer over to the operator for production, verify all dryer enclosure  
panels, guards and safety devices are in place and functioning properly.  
Reporting a Safety Defect  
If you believe that your equipment has a defect that could cause injury, you should  
immediately discontinue its use and inform the manufacturer.  
The principle factors that can result in injury are failure to follow proper operating procedures  
(i.e. lockout/tagout), or failure to maintain a clean and safe working environment.  
Dehumidifying Dryers  
Chapter 1: Safety  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidifying Dryers  
Chapter 1: Safety  
x
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Functional Description  
2-1 Models Covered in This Manual  
This manual provides operation, installation, and maintenance instructions for 15, 30, and 60  
cfm dehumidifying dryers. Model numbers are listed on the serial tag. Make sure you know  
the model and serial number of your equipment before contacting the manufacturer for parts  
or service.  
Our dehumidifying mini dryers are designed to generate heated dehumidified air at carefully  
controlled temperatures for use in plastic drying systems. Drying systems are sized to meet  
the specific requirements stated by the Customer at the time of purchase.  
2-2 General Description  
Dehumidifying dryers are used to generate very low dew point air heated to a controlled  
temperature for drying plastic pellets and regrind.  
Our dryers force hot, dry air through resin in a drying hopper, where air picks up moisture  
from the material and draws it back to the dryer. In the dryer, a desiccant bed strips moisture  
from the air. The dried process air is then re-heated and delivered back into the drying  
hopper to continue to remove moisture.  
Figure 15: Typical Dryer Air Flow Schematic  
Moisture  
Exhaust  
High pressure  
prepheral blower  
Drying Hopper  
Valve  
Filter (Separates  
Dust)  
Ambient  
Air Flow  
Dehumidifying Dryers  
Chapter 2: Functional Description  
11 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A small amount of ambient air is introduced into the process air stream to make up for the air  
lost during the bed regeneration. Because the process air is typically much drier than the  
ambient air, the air mixture maintains drying efficiency at a consistently high level. This air  
is heated to 500° F (260° C) before entering the bed that is on regeneration forcing moisture  
from the desiccant before exhausting. To compensate for the humidity content in the air, this  
dryer is supplied with the proper amount of desiccant.  
What is desiccant?  
Desiccant is a material that attracts and holds (absorbs) water from the air. The desiccant our  
dryers use is a synthetic crystalline metal aluminosilicate blended with a clay binder and  
formed into beads.  
The Process/Regeneration Cycle  
Our dryers have two desiccant beds. While one bed is on-line in the process air loop, the  
other is off-line, being regenerated.  
When a desiccant bed is on-line, it absorbs moisture from the process air. In time, the bed  
becomes saturated with moisture and needs to be regenerated. The dryer automatically  
redirects the process airflow to the second bed, and starts the regeneration cycle on the first  
bed.  
During regeneration, the dryer system heats air and forces it through the desiccant bed. The  
moisture driven off the bed bleeds to the atmosphere.  
2-3 Standard Features  
Mechanical Features  
Dual desiccant beds  
Electrically-actuated air valve  
13X Molecular Sieve  
Single regenerative process blower  
Drying temperature range of 180ºF to 250ºF (71° C to 121° C).  
2.5” hose connections  
Electrical Features  
Process thermocouple to be connected to drying hopper air inlet.  
Nema 12 control enclosure  
Dehumidifying Dryers  
Chapter 2: Functional Description  
12 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NFPA79 machinery electrical standards  
Non-fused electrical disconnect  
Branch fusing  
Mercury process heater contactor  
Regeneration temperature control  
Process high temperature alarm light  
Process/regeneration heater box  
High temperature safety system (Process/Regeneration)  
Dew point monitor with digital read-out  
Controller Features  
Mitsubishi programmable relay controller  
Display of process temperature set point and actual settings  
2-4 Options  
Options marked with “*” indicate options that can be factory installed or retrofitted in the  
field.  
* Process temperature 180ºF to 400˚ F, including aftercooler inside dryer  
and silicone insulated delivery hose.  
* Process temperature 120˚ F to 250˚ F, includes precooler on back of dryer.  
* If the dryer is a central dry air generator, it will not have a process heater  
box.  
* Plasticizer trap (with cooling coil) in lieu of optional aftercooler (mounts  
outside on back of dryer).  
* Machine mount adapter to accommodate a dryer and corresponding  
hopper.  
* Drawer magnet, stainless steel construction.  
* Casters, two (2) fixed and two (2) swivel.  
* Cart with caster with hopper mounting place.  
* Redundant high temp safety control.  
* Audible alarm  
* Insulated air hose for air delivery  
2-5 Safety Devices and Interlocks  
This section includes information on safety devices and procedures that are inherent to the  
Dryer. This manual is not intended to supersede or alter safety standards established by the  
user of this equipment. Instead, the material contained in this section is recommended to  
supplement these procedures in order to provide a safer working environment.  
At the completion of this section, the operator and maintenance personnel will be able to do  
the following:  
Dehumidifying Dryers  
Chapter 2: Functional Description  
13 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Identify and locate specific safety devices.  
Understand the proper use of the safety devices provided.  
Describe the function of the safety device.  
Safety Circuit Standards  
Safety circuits used in industrial systems protect the operator and maintenance personnel  
from dangerous energy. They also provide a means of locking out or isolating the energy for  
servicing equipment.  
Various agencies have contributed to the establishment of safety standards that apply to the  
design and manufacture of automated equipment. The Occupational Safety and Health  
Administration (OSHA) and the Joint Industrial council (JIC) are just a few of the  
organizations that have joined with the plastics industry to develop safety standards.  
Every effort has been made to incorporate these standards into the design of the dryer;  
however, it is the responsibility of the personnel operating and maintaining the equipment to  
familiarize themselves with the safety procedures and the proper use of any safety devices.  
Fail Safe Operation  
If a safety device or circuit should fail, the design must be such that the failure causes a  
“Safe” condition. As an example, a safety switch must be a normally open switch. The switch  
must be held closed with the device it is to protect. If the switch fails, it will go to the open  
condition, tripping out the safety circuit.  
At no time should the safety device fail and allow the operation to continue. For  
example, if a safety switch is guarding a motor, and the safety switch fails, the motor should  
not be able to run.  
Safety Device Lock-Outs  
Some safety devices disconnect electrical energy from a circuit. The safety devices that are  
used on these dryers are primarily concerned with electrical power disconnection and the  
disabling of moving parts that may need to be accessed during the normal operation of the  
machine.  
Some of the safety devices utilize a manual activator. This is the method of initiating the  
safety lock out. This may be in the form of a plug, lever or a handle. Within this lockable  
handle, there may be a location for a padlock. Personnel servicing the equipment should  
place a padlock in the lockout handle.  
In addition to the safety devices listed above, these dryers are equipped with a line cord plug.  
This allows the operator or maintenance personnel to unplug the dryer from its power source  
and tag it out. The plug can then be tagged with any number of approved electrical lockout  
tags available at most electrical supply stores.  
WARNING! Always disconnect and lockout all electrical power and pneumatic (i.e. compressed air)  
sources prior to servicing or cleaning the dryer. Failure to do so may result in serious  
injury. No one but the person who installed the lockout may remove it.  
Dehumidifying Dryers  
Chapter 2: Functional Description  
14 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Installation  
3-1 Uncrating the Equipment  
Dehumidifying Dryers are shipped mounted on a skid, enclosed in a plastic wrapper, and  
contained in a cardboard box.  
1. Pry the crating away from the skid.  
Note: Remove the nails holding the box to the skid and lift the box  
off carefully; avoiding staples in the 1’ x 4’ wood supports.  
Cut the steel banding.  
2. Use a pry bar to remove the blocks securing the unit to the skid.  
3. Lift unit from sides. Use a pry bar if necessary to carefully remove the  
skid from the unit.  
4. Lower slowly.  
3-2 Rigging and Placing the Dryer  
Take care when rigging and placing the dryer. Figures 1, 2 and 3 on the following pages show  
a suggested safe rigging diagram. It lets you lift the dryer/hopper unit vertically for  
installation on the machine throat. Adjust chain lengths at the center sling bracket before you  
lift the unit. Your dryer has built-in lifting lugs.  
Caution!  
If you are mounting a machine-mount dryer with a magnet or transition adaptor on the  
machine throat, you must provide additional support to hold the dryer securely on the  
machine.  
Be aware that off-center static and dynamic hopper loading can occur with machine  
vibration. Again, provide additional support to hold the dryer securely on the machine.  
For 60 cfm dryer units, you must provide additional support to stabilize these units and  
to protect personnel when installing on machine throats.  
Use caution and observe safety rules when lifting and placing your dryer!  
Dehumidifying Dryers  
Chapter 3: Installation  
15 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 16: Machine-Mount Dryer Dimensions  
Mounting flange  
E
E
Diameter hole:  
F
ON  
Notes: Hopper mounting flanges on 0.75 and  
and 1.5 cu. ft. (20 & 40 liter) hoppers  
are supplied blank so the customer  
PROCESS  
DEW POINT  
TEMPERATURE  
CONTROL POWER  
ALARM HORN  
ON  
OFF  
ALARM  
ALARM Silencer  
can drill to match existing machine throat.  
3.0 cu. ft. (80 liter) hoppers and larger  
are not supplied with a cast flange  
(as shown).  
D
A
15, 30, 60 cfm machine-mount dimensions in inches/cm  
15 cfm 30 cfm  
60 cfm  
0.7 ft.3/20 liters 1.5 ft.3/40 liters 1.5 ft.3/40 liters 3.0 ft.3/80 liters 4.0 ft.3/120 liters 6.0 ft.3/160 liters  
Dimension in.  
cm  
104  
91  
76  
89  
in.  
43  
37  
30  
35  
4
cm  
109  
94  
76  
89  
in.  
43  
37  
30  
35  
4
cm  
109  
94  
76  
89  
in.  
46  
44  
30  
35  
7
cm  
117  
112  
76  
89  
17.8  
5.1  
in.  
56.75  
50  
34  
45.75  
7
cm  
144  
127  
86  
116  
17.8  
5.1  
in.  
56.75  
62  
34  
45.75  
7
cm  
144  
158  
86  
116  
17.8  
5.1  
A
B
C
D
E
F
41  
36  
30  
35  
4
10.2  
3.8  
10.2  
3.8  
10.2  
3.8  
1.5  
1.5  
1.5  
2
2
2
Dehumidifying Dryers  
Chapter 3: Installation  
16 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 17: Floor-Mount Dryer Dimensions  
ON  
PROCESS  
TEMPERATURE  
DEW POINT  
CONTROL POWER  
ON OFF  
ALARM HORN  
ALARM  
ALARM Silencer  
A
E
15, 30, 60 cfm floor-mount dimensions in inches/cm  
15 cfm 30 cfm  
60 cfm  
Dimension  
in.  
20  
32.5  
30  
30  
23.75  
cm  
51  
83  
76  
76  
60  
in.  
20  
32.5  
30  
30  
cm  
51  
83  
76  
76  
60  
in.  
24  
32.5  
30  
34  
28  
cm  
61  
83  
76  
86  
71  
A
B
C
D
E
23.75  
Dehumidifying Dryers  
Chapter 3: Installation  
17 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 1: Suggested Lift Rigging for Cart Mounted Dryers  
DO NOT  
USE  
ON  
P
ROCESS  
DEW POINT  
TEMPERATURE  
CONTROL POWE  
ON OFF  
R
ALARM HOR  
N
ALARM  
ALARM Silencer  
USE  
FORK  
LIFT  
TRUCK  
Caution!  
Do not use a hoist to move or rig your Dryer when it is mounted on a cart!  
Moving the Dryer with a hoist will cause it to become unstable and may  
cause damage to the Dryer and/or injury to personnel!  
Recommended Dryer Lifting Hardware  
Item  
Quantity  
Description  
Adjustable alloy chain sling  
Existing hopper lifting bracket  
Drop forged steel eye nut  
Chain connector  
Vendor  
McMaster-Carr  
McMaster-Carr  
McMaster-Carr  
Vendor part no.  
33665T32  
1
2
3
4
1
2
1
1
3019T15  
3712T23  
Figure 2: Suggested Lift Rigging for Floor Mounted Dryers  
USE  
Overhead  
Crane  
ON  
PROCESS  
TEMPERATURE  
DEW POINT  
USE  
CONTROL POWER  
ON OFF  
ALARM HORN  
ALARM  
ALARM Silencer  
FORK  
LIFT  
TRUCK  
Note: Floor Mounted Dryers can be lifted by hoist or fork lift.  
Dehumidifying Dryers  
Chapter 3: Installation  
18 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 3: Suggested Lift Rigging for Machine Mounted Dryers  
ON  
PROCESS  
DEW POINT  
TEMPERATURE  
CONTROL POWER  
A
LAR  
M
HORN  
ON  
OFF  
ALARM  
ALARM Silencer  
Caution!  
When using a hoist to move a machine mounted dryer, ALWAYS attach  
chains to the three (3) locations/lifting points on the unit! Moving the  
Dryer without the chains attached to all of the lifting points will cause the  
unit to become unstable and may cause damage to the Dryer and/or injury  
to personnel!  
3-3 Electrical Connections  
When making electrical connections to your dryer, ensure that you take into consideration  
and make arrangements for the following:  
A qualified electrician should make all electrical connections.  
Fulfill all national, state, and local safety and electrical code requirements.  
The serial tag lists voltage, phase, and amp draw information:  
Line voltage must be within plus or minus ten percent (±10%) of the  
voltage listed on the serial tag, or damage may occur. Phase imbalance  
must be less than two percent (2%).  
Connect main power to the dryer at the disconnect or terminals in the upper right  
corner of the control enclosure.  
Install a fused disconnect with a lockout feature in the power main leading to the dryer.  
The power drop must include a ground wire.  
Make sure all electrical connections are tight.  
Dehumidifying Dryers  
Chapter 3: Installation  
19 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-4 Setup Procedures  
This section provides the procedures necessary for configuring your Dehumidifying Dryer.  
Configuration of your dryer includes checking for proper blower rotation, making  
dryer/drying hopper process air connections and the optional aftercooler (on 60 cfm models).  
We recommend that you carry out these procedures in the order given here.  
Note: Before carrying out these procedures, install all equipment as  
described in this section.  
Checking for Proper Blower Rotation  
Three-Phase Models  
Caution!  
In three-phase models, incorrect phasing of power leads can cause  
backward rotation of blower motors and CONTAMINATION OF THE  
DESICCANT!  
Always check blower rotation before putting material in the drying hopper!  
The blower is rotating properly when air flows from the delivery outlet.  
Note: Holding your hand in front of the air return will also indicate if the  
blower rotates in the proper direction.  
If the three-phase blower rotates improperly, reverse any two wires at the fused disconnect  
outside the dryer or at the disconnect/terminal in the control enclosure. This assures that the  
blower rotates in the proper direction.  
Making Dryer/Drying Hopper Process Air Connections  
Floor Mount Models  
When making process air connections to your floor mounted dryer, ensure that you take into  
consideration and make arrangements for the following:  
Use high-temperature flexible dryer hose or rigid tubing to connect the dryer to the  
drying hopper.  
Keep the delivery hose to the drying hopper as short as possible to minimize heat loss.  
We strongly recommend insulated hose for maximum energy savings.  
Do not use insulated hose on the return from the drying hopper.  
The return air to the blower must be 150°F (66ºC) or below. If the return air  
temperature is not below this point, you should purchase and install the optional  
aftercooler to remove excessive heat. Consult the manufacturer for more information.  
Aftercooler considerations also apply to machine-mount models.  
Make sure that hoses are not kinked or collapsed.  
Drying hopper air inlet and outlet locations vary, but always connect hoses so the dry  
process air from the dryer enters the bottom of the drying hopper and flows out the top  
to return to the dryer inlet.  
Dehumidifying Dryers  
Chapter 3: Installation  
20 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Drying Hopper Air Trap Considerations  
Our exclusive air trap assembly on the top of the drying hopper prevents ambient air from  
contaminating the material being dried. To ensure that your unit will operate at peak  
efficiency, do the following:  
Keep the material level at the mid point of the air trap  
This can be achieved by utilizing a hopper loader or vacuum conveying system to  
supply material to the drying system.  
Figure 1: Drying Hopper Air Trap  
Flapper Valve  
of the loader  
Suggested material level  
for the optimum  
efficiency.  
Return air from the  
drying hopper.  
Air Trap  
Insulation  
Delivery low dew point,  
heated air to the drying  
hopper.  
Recommended process  
temperature control  
thermocouple location.  
Optional Aftercooler  
Water-cooled 15/30/60 cfm models use a water-to-air heat exchanger as an aftercooler.  
Cooling water is required for this design (3 gpm at 85°F or lower). Return air from the  
hopper passes through the air filter to trap fines and dust before entering the heat exchanger.  
Installing Water Lines  
(Hose and Hose Clamp)  
When installing the water lines, ensure that the aftercooler utilizes either tower, chilled or city  
water as warm as 85°F (29°C). Recommended flow rate is three (3 gpm) gallons per minute  
(11 liters per minute).  
Dehumidifying Dryers  
Chapter 3: Installation  
21 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-5 Initial Start-up  
Pre-Startup Checks  
; Check the process and return hoses for tight connections.  
; Check all companion equipment, such as the drying hopper; verify that the loading  
system is ready for operation.  
; Verify that all dryer electrical connections are tight.  
Starting Up the Dryer  
1. Turn on (energize) the disconnect switch in your power drop, then turn on the one on  
the dryer.  
2. Turn the system ON/OFF switch to ON to energize the display panel.  
3. Close the slidegate at the bottom of the drying hopper.  
Make sure that the blowers turn in the right direction.  
4. Fill the drying hopper with material.  
5. Turn the dryer ON switch to START to start the dryer.  
The process blower starts.  
6. If your dryer has a water-cooled aftercooler, make sure that sufficient cooling water  
(3gpm at 85°F or lower) flows properly through the coil and that you have bled any  
trapped air from the system. Make sure the aftercooler has the proper supply water  
temperature.  
7. Set the process set point on the temperature controller.  
8. After the proper pre-drying time for the initial hopper fill has elapsed, fully open the  
drying hopper slide gate.  
9. Turn on the machine convey ON/OFF switch to ON, and set the convey timer for the  
proper conveying time.  
Note: To allow proper residence time during continuous processing,  
maintain the material level in the hopper at the midpoint of the air trap  
assembly.  
Auto-Tuning the Dryer  
1. For Auto-tuning, press the beige button once. The AT screen will show with the  
setting OFF.  
2. Press the UP arrow to change the setting to ON.  
3. Press the beige button again to go back to the Temperature Screen. Your actual  
temperature will start to flash for about 10-20 minutes with the temperature  
fluctuating up and down during that period. After the flashing stops, it means auto-  
tuning has finished.  
Dehumidifying Dryers  
Chapter 3: Installation  
22 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Shutting Down the Dryer  
1. Turn off the conveying system supplying the drying hopper.  
2. When processing is complete, close the hopper slide gate and shut down any in-line  
companion equipment, such as the aftercooler.  
3. Turn the Dryer ON/OFF selector switch to OFF.  
4. Turn the system ON/OFF switch to OFF.  
5. If needed, empty the drying hopper.  
6. For maintenance or a long term shutdown, open (de-energize) the electrical  
disconnects at the dryer and at the power drop.  
Dehumidifying Dryers  
Chapter 3: Installation  
23 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Operation  
4-1 Start-up  
1. Turn on (energize) the disconnect switch in your power drop, then turn on the one on  
the dryer.  
2. Turn the system ON/OFF switch to ON to energize the display panel.  
3. Close the slidegate at the bottom of the drying hopper.  
Make sure that the blowers turn in the right direction.  
4. Fill the drying hopper with material.  
5. Turn the dryer ON switch to START to start the dryer.  
The process blower starts.  
6. If your dryer has a water-cooled aftercooler, make sure that sufficient cooling water  
(3gpm at 85°F or lower) flows properly through the coil and that you have bled any  
trapped air from the system. Make sure the aftercooler has the proper supply water  
temperature.  
7. Set the process set point on the temperature controller.  
8. After the proper pre-drying time for the initial hopper fill has elapsed, fully open the  
drying hopper slide gate.  
9. Turn on the machine convey ON/OFF switch to ON, and set the convey timer for the  
proper conveying time.  
Note: To allow proper residence time during continuous processing,  
maintain the material level in the hopper at the midpoint of the air trap  
assembly.  
Dehumidifying Dryers  
Chapter 4: Operation  
24 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-2 Controller Description and Operation  
Identifying Control Panel Indicator Lights and Switches for the Standard  
Controller  
Switches  
System OFF/ON/START Switch. This switch energizes or de-energizes control power to  
the indicator panel and starts the dryer. (The controller can be energized without the dryer  
running.)  
Optional Alarm Silence Switch. Press this switch to silence the horn when a high  
temperature process/regeneration or blower failure alarm activates.  
Indicator Lights  
Alarm Light. This feature works in conjunction with the alarm horn to warn the operator of  
a high bed safety temperature, a regeneration heater fault, or a blower failure. This warning  
is reset by pressing the alarm silence button.  
Figure 4: Typical Dryer Control Panel  
Dehumidifying Dryers  
Chapter 4: Operation  
25 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Process Air Temperature Controller  
Our dryers use a microprocessor-based PID temperature controller for maintaining process air  
temperature. The controller is a modular, self-contained unit you can remove from the  
mounting housing. All parameters except for the process air set point are factory set and  
adjusted; normally, no field adjustment to the internal controls is necessary.  
Figure 5: Typical Process Air Temperature Controller  
PV  
SV  
Identifying Process Air Temperature Controller LED Indicators  
Indicator  
Name  
Description  
PV  
Process Value  
Numeric LED  
During normal operation, the process value (PV)  
numeric LED indicator displays the process  
temperature at the To Process thermocouple. It  
also lists parameters during setup and error  
messages if any errors occur.  
8.8.8.8  
SV  
Set Value  
Numeric LED  
During normal operation, the set value (SV)  
numeric LED indicator displays the process set  
point temperature selected for the dryer. The dryer  
then maintains this set point temperature. This  
LED indicator also displays parameter and pre-set  
function values during configuration setup.  
8.8.8.8  
OUT1  
Out 1 LED  
Lit when Control Output 1 is on. The Out1  
indicator lights when the controller signals the  
process heaters to be energized.  
OUT2  
AT  
Out 2 LED  
AT LED  
Lit when Control Output 2 is on. Not used in  
this application.  
Flashes during auto-tuning in process value (PV)  
screen.  
Dehumidifying Dryers  
Chapter 4: Operation  
26 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Indicator  
Name  
Description  
ALARM1  
ALARM 1 LED  
Lights in the Operation Indicator Section when  
the output function assigned to auxiliary output  
1 turns on. The ALARM1 indicator lights when  
the process temperature exceeds the set point  
temperature by more than the alarm deviation  
value. Alarm output de-energizes the heaters.  
Heaters re-energize when the temperature falls  
within the acceptable range.  
Identifying Temperature Controller Keys  
Indicator  
Name  
Description  
Mode Key  
Press the Mode key to shift the display to the next  
set of parameters. The menu screen displays.  
Down Key  
Up Key  
Press the Down arrow key to lower the process air  
set point temperature. During setup, it lets you  
decrease the value of the parameter displayed on  
the set point LED readout.  
Press the Up arrow key to raise the process air set  
point temperature. During setup, it lets you  
increase the value of the parameter displayed on  
the set point LED readout.  
Setting the Process Air Temperature  
When setting the process air temperature, consult with the resin manufacture for the  
recommended drying temperature.  
To change the process air temperature set point with the dryer running:  
Press  
to raise the set point to the temperature you want.  
to lower the set point to the temperature you want.  
Press  
Dehumidifying Dryers  
Chapter 4: Operation  
27 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Restoring the Process Air Temperature Controller (E5CN) to Factory Settings  
If the preset parameters on the controller have been tampered with and it no longer properly  
controls temperature and displays dew point, you can restore the controllers to the factory  
setup. Call the Service Department for detailed instructions.  
E5CN Operating Parameters  
The E5CN controller has several mode selections. Within each mode are numerous  
parameters that can be set.  
The factory has set the security level to protect the critical parameters from being accidentally  
changed. Below is an explanation of the operating modes you will have access to and on the  
following page are the manufacturers’ default settings.  
Available E5CN Modes  
Operation Level  
Indicator  
Name  
Description  
Run/Stop Mode  
(r-S)  
When “RUN” is selected, the control is running.  
When “STOP” is selected, the control is stopped.  
When the control is stopped, the STOP display  
lights. The default is set to “RUN.”  
Alarm Value 1  
Mode (AL-1)  
This setting is used to indicate how many degrees  
the process temperature will be allowed to exceed  
the set point temperature. An alarm output will de-  
energize the heaters.  
Dehumidifying Dryers  
Chapter 4: Operation  
28 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjustment Level  
Indicator  
Name  
Description  
Auto-Tune Mode  
(At)  
See Page 19 of Chapter 3 for instructions on how  
to Auto-Tune your dryer.  
Note:Although the controller is calibrated at  
the factory, the manufacturer  
recommends that the unit be Auto-  
Tuned prior to dryer startup.  
Temperature Input This setting is used to offset an error between the  
Shift Mode (TnS)  
set point and the actual temperature. The entire  
input range is shifted by a set figure  
preprogrammed by the operator.  
Proportional Band  
Mode (P)  
This setting controls the amount in which the  
manipulated variable (MV) is proportionate to the  
deviated value or controller error.  
Integral Time  
Mode (I)  
Setting this feature, gives the control an action that  
is proportionate to the time integral of the control  
error. By using this setting, proportional action is  
used in combination with integral action to offset  
the control error and the set point will begin to  
match the control temperature (PV or process  
value).  
Derivative Time  
Mode (d)  
Setting the derivative control provides the  
controller with the ability to correct for a future  
error in the previously set process output.  
Dehumidifying Dryers  
Chapter 4: Operation  
29 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Entering Operating Parameters to Select Modes  
To enter the display:  
1. Press the  
2. Press  
Mode Display key to view the Run/Stop & Alarm 1 Modes.  
to set the higher or lower the values of the parameter or turn  
and  
that function On or Off.  
The SV readout displays the different values for the parameter within a mode.  
3. To switch modes within a level, press and hold the  
(1) second.  
Level Display key for one  
The PV readout will display the different parameters within each mode.  
4. Use short presses on the  
a mode.  
Mode Display key to display each parameter within  
The SV readout displays the different values for the parameter within a mode.  
5. Press  
and  
to set the higher or lower the values of a parameter or turn  
that function On or Off.  
6. Press  
Level Key once to return to the Process Temperature Setting.  
Figure 6: Settings for Process Temperature Controller (E5CN), Part No. A0555757  
Mode  
Parameter  
Run/Stop  
Alarm value 1  
Setting range  
Run/Stop  
-1999 to 9999  
Default  
Run  
0
Manuf. setting  
-
25  
Operation  
Mode  
Parameter  
Setting range  
ON, OFF  
-199.9 to 999.9  
0.1 to 999.9  
0 to 3999  
Default  
OFF  
0.0  
8.0  
233  
40  
Manuf. setting  
AT execute/cancel  
Temperature input shift  
Proportional Band  
Integral Time  
?
-
?
?
?
Adjustment  
Derivative Time  
0 to 3999  
Dehumidifying Dryers  
Chapter 4: Operation  
30 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Process Air Dew Point Display  
Optional  
The Process Air Dew Point meter indicates the current process air delivery moisture content.  
Standard dryers use a microprocessor-based controller for displaying dew point air  
temperature. The controller is a modular, self-contained unit removable from the mounting  
housing. All parameters are factory set and adjusted; normally, no field adjustment to the  
internal controls are necessary.  
Figure 7: Typical Dew Point Display Monitor  
PV  
SV  
OUT1  
OUT2 MANU STOP RMT  
AT  
SUB1  
AT  
OMRON  
E5CK  
Note: The only functional buttons on this contoller are the up and down keys.  
Setting the High Dew Point Alarm  
The high dew point alarm setting is changed by pressing the up and down keys to input the  
alarm value. The factory setting for Alarm Value 1 (AL-1 ) is -10°F (-23°C).  
Restoring the Process Air Dew Point Meter (E5CK) to Factory Setup  
If the preset parameters on the controller have been tampered with and it no longer functions  
properly, call the Service Department. This controller is not meant to be modified.  
Note: The dew point alarm monitors and indicates a deviation from the set  
point.  
Dehumidifying Dryers  
Chapter 4: Operation  
31 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Redundant Safety Controller Display  
Optional  
The Redundant Safety Controller limits the process air temperature from exceeding the upper  
temperature range set by the E5CN Temperature Controller. Standard dryers use a  
microprocessor-based controller for limiting the process air temperature. The controller is a  
modular, self-contained unit removable from the mounting housing. All parameters are  
factory set and adjusted; normally, no field adjustment to the internal controls are necessary.  
Figure 8: Typical Redundant Safety Controller Display  
Setting the Redundant Safety Controller  
The Redundant Safety Controller alarm setting is changed by pressing the up and down keys  
to input the alarm value. The upper display reading indicates the Process Value, while the  
lower display indicates the High Point Setting alarm value. The factory setting for the High  
Point Alarm Value (L1-hi ) is 150°F (-23°C).  
Restoring the WATLOW Redundant Safety Controller to Factory Setup  
If the preset parameters on the controller have been tampered with and it no longer functions  
properly, call the Service Department. This controller is not meant to be modified.  
WATLOW Operating Parameters  
The WATLOW controller has only one mode selection; ALARM.  
The factory sets the security level to protect the critical parameters from being accidentally  
changed. Below is an explanation of the modes you will have access to and the manufacturer  
default settings.  
Dehumidifying Dryers  
Chapter 4: Operation  
32 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Entering Operating Parameters to Select Modes  
To enter the display:  
1. Press both the Up  
and Down  
keys for three seconds from the home page.  
The word SEE will appear in the upper display and PAGE will appear in the lower  
display.  
2. Press the Advance Key  
3. Press the Up or Down  
to move through the parameter prompts.  
keys to change the parameter value.  
4. Press the RESET Key at any time to return to the Home Page display.  
Figure 9: Setting List for Redundant Safety Controller (WATLOW), Part No. A0555757  
Mode  
SEn  
Lin  
Parameter  
Sensor Type  
Thermocouple Linearization 0-10  
Setting range  
Default  
Manf. setting  
0-3  
0
0
-
H (1)  
C-F  
Temperature Units  
Temp. Decimal Places  
INFOSENSE™  
Fahrenheit / Celsius  
0 – 0.0  
Yes / No  
4.00 to 20.00 mA  
1.00 to 10.00V  
4.00 to 20.00 mA  
1.00 to 10.00V  
-999 to 999  
Off, DiSP, Cont, both  
Limit (2)  
Both, High, Low  
0.0 to 999.0  
Off / Process Alarm / Limit (2)  
Both / high / low  
F
0
No  
-
-
-
S.dEC  
IS.En  
Sc.Lo  
Process Scale Low  
4.00 mA  
1.00V  
20.00 mA  
5.00 V  
0
0
Sc.hi  
Process Scale High  
400  
CAL  
Ftr.E  
Ot 1  
LSd1  
hyS1  
Ot2  
Calibration Offset  
Input Filter  
-
-
-
OFF  
(2)  
Both  
1.0  
OFF  
Both  
Output 1 Function  
Output 1 Limit Sides  
Limit 1 Hysteresis  
Output 2 Function  
Output 2 Sides  
High  
-
-
-
LSd2  
None, Process Value, Limit 1 Low Set,  
Limit 1 High Set, Limit 2 Low Set, Limit  
2 High Set, Alarm 2 Low Set, Alarm 2  
High Set, Limit 3 Low Set, Limit 3 High  
Set, Alarm 3 Low Set, Alarm 3 High Set  
None, Process Value, Limit 1 Low Set,  
Limit 1 High Set, Limit 2 Low Set, Limit  
2 High Set, Alarm 2 Low Set, Alarm 2  
High Set, Limit 3 Low Set, Limit 3 High  
Set, Alarm 3 Low Set, Alarm 3 High Set  
(0) no lockout, (1) Programming and  
Setup Page Locked, (2) Limit Set  
Points are the only Operation Page  
parameters accesible, (3) Full Lockout.  
UdSP  
Upper Display Look  
Process  
-
Limit 1  
High Set  
LdSP  
LOC  
Lower Display Look  
Lockout  
-
0
2
Dehumidifying Dryers  
Chapter 4: Operation  
33 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-3 Dryer Operation Procedures  
Controller Operation (Without Optional Alarm Horn & Reset Button)  
1. Turn the disconnect on the control panel to the ON position. Power is applied to the  
voltage line fuses, line side of the control power switch and the temperature  
controller.  
2. Turn the control power switch to the ON position. Power is applied to the  
programmable relay and dew point controller. The valve will move to the start  
position as follows:  
a. The valve motor rotates until the cam switch makes 2 transitions.  
b. If the cam switch does not make a transition within 10 seconds, a valve  
motor fault is generated. “VALVE MTR” is displayed on the relay screen,  
the alarm light is activated. The valve motor, heaters, and blower shut off.  
To restart the dryer, cycle control power to deactivate the alarm light and  
restart the valve motor sequence.  
Note: The relay screen which contains the Alarm Display Messages is located  
inside the controller enclosure. For a list of Alarm Display Messages,  
see Page 35.  
WARNING! Do not attempt to check the Alarms on the Controller located within the  
unit enclosure unless you are a qualified electrician!  
c. The valve will normally complete one full cycle (revolution).  
If the drying process shuts down due to an alarm, the dryer has been setup to  
have the following operational features:  
The bed in process at power-down will remain in process.  
The bed in regeneration at power-down will remain in regeneration.  
The regeneration timing cycle will restart from the beginning.  
Dehumidifying Dryers  
Chapter 4: Operation  
34 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Once the control power is on and no fault conditions exist, turning the OFF-ON-  
START switch to the START position will start the dryer as follows:  
a. The process heater is turned on and controlled by the E5CN controller.  
b. The process/regen blower is started.  
c. The regen heater is turned on and the regeneration timing sequence is  
initiated. The regen heater is controlled by the E5C2 controller. For default  
timing settings for regeneration, see the table below.  
Model  
15 cfm  
30 cfm  
60 cfm  
Heating  
35  
Cooling  
30  
35  
30  
Note: In a humid environment, you may change the setting to 40 / 25 for  
better results.  
4. If either the left or right bed safety temperature switch opens, a regen heater fault is  
generated. “HIGH TEMP” is displayed on the relay screen. The alarm light is  
activated. The process heater, regen heater, and process/regen blower are turned off.  
Turn the Off-On-Start switch to the START position to deactivate the alarm light and  
restart the dryer. If the switch is still open, the dryer will not restart.  
5. If the OMRON controller faults, the optional redundant high temperature safety  
device opens, or the process heater safety switch opens, a heater fault is generated.  
“HIGH TEMP” is displayed on the relay screen. The alarm light is activated. The  
process heater, regen heater, and process/regen blower are turned off.  
Turn the OFF-ON-START switch to the START position to deactivate the alarm  
light and restart the dryer. If the fault condition still exists, the dryer will not restart.  
6. If the process blower overload trips, a process blower fault is generated. “PROC  
BLWR” is displayed on the relay screen. The alarm light is activated. The process  
heater, regen heater, and process/regen blower are turned off.  
Reset the motor overload and turn the Off-On-Start switch to the START position to  
deactivate the alarm light and restart the dryer.  
7. The valve position limit switch enables the right bed heater and provides an input  
signal to the programmable relay when actuated by the cam lobe. When the cam lobe  
position is high, the right bed is activated. When the cam lobe position is low, the  
left bed is activated. Each heater is ON-OFF controlled by the OMRON E5C2  
controller.  
8. Upon completion of the HEAT portion of the regeneration sequence, the regen  
heaters are disabled by the programmable relay and the COOL time begins.  
9. Once the Cool time has expired, the valve motor is turned on until the cam switch  
makes a transition. Upon making a transition, the timing sequence is restarted for the  
new bed.  
10. When no fault conditions exist, the display reads “SYSTEM NORMAL”.  
Dehumidifying Dryers  
Chapter 4: Operation  
35 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. When a dew point fault is generated by the optional dew point controller, the alarm  
light will activate. The alarm light will flash, indicating a non-critical fault. Press  
Alarm Reset to deactivate the alarm until the next dew point fault occurs.  
12. The top 2 lines of the display show the HEAT and COOL times (in minutes) for the  
regeneration sequence. Changes to these times can be made by the operator as  
follows:  
a. Press the up or down arrow until the cursor is positioned at the number to be  
changed.  
b. Press the “+” key to increment the number, or the “-“ key to decrement the  
number.  
c. Press the “OK” key to accept the value and write to the relay memory.  
OR  
d. Press the “ESC” key to cancel the changes.  
Note: A change will NOT take effect until step 12-c is done.  
13. The dryer is shut off by turning the control power switch to the OFF position.  
14. Refer to Schematic drawing A0566087 enclosed in the control enclosure.  
Dehumidifying Dryers  
Chapter 4: Operation  
36 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controller Operation (With Optional Alarm Horn & Reset Button)  
1. Turn the disconnect on the control panel to the ON position. Power is applied to the  
voltage line fuses, line side of the control power switch and the temperature  
controller.  
2. Turn the control power switch to the ON position. Power is applied to the  
programmable relay and dew point controller. The valve will move to the start  
position as follows:  
a. The valve motor rotates until the cam switch makes 2 transitions.  
b. If the cam switch does not make a transition within 10 seconds, a valve  
motor fault is generated. “VALVE MTR” is displayed on the relay screen,  
the alarm horn and light are activated. The valve motor, heaters, and blower  
shut off. Pressing the ALARM RESET pushbutton will deactivate the alarm  
horn and light.  
Cycle control power to restart the dryer.  
Note: The relay screen which contains the Alarm Display Messages is located  
inside the controller enclosure. For a list of Alarm Display Messages,  
see Page 35.  
WARNING! Do not attempt to check the Alarms on the Controller located within the  
unit enclosure unless you are a qualified electrician!  
c. The valve will normally complete one full cycle (revolution).  
If the drying process shuts down due to an alarm, the dryer has been setup to  
have the following operational features:  
The bed in process at power-down will remain in process.  
The bed in regeneration at power-down will remain in regeneration.  
The regeneration timing cycle will restart from the beginning.  
3. Once the control power is on and no fault conditions exist, turning the Off-On-Start  
switch to the START position will start the dryer as follows:  
a. The process heater is turned on and controlled by the E5CN controller.  
b. The process/regen blower is started.  
c. The regen heater is turned on and the regeneration timing sequence is  
initiated. The regen heater is controlled by the E5C2 controller. Default  
timing for regeneration is 35 minutes for HEATING and 30 minutes for  
COOLING.  
4. If either the left or right bed safety temperature switch opens, a regen heater fault is  
generated. “HIGH TEMP” is displayed on the relay screen. The alarm horn and  
light are activated. The process heater, regen heater, and process/regen blower are  
turned off. Pressing the ALARM RESET pushbutton will deactivate the alarm horn  
and light.  
Turn the Off-On-Start switch to the START position to restart the dryer. If the  
switch is still open, the dryer will not restart.  
Dehumidifying Dryers  
Chapter 4: Operation  
37 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. If the OMRON controller faults, the optional redundant high temperature safety  
device opens, or the process heater safety switch opens, a process heater fault is  
generated. “HIGH TEMP” is displayed on the relay screen. The alarm horn and  
light are activated. The process heater, regen heater, and process/regen blower are  
turned off. Pressing the ALARM RESET pushbutton will deactivate the alarm horn  
and light.  
Turn the Off-On-Start switch to the START position to restart the dryer. If the fault  
condition still exists, the dryer will not restart.  
6. If the process blower overload trips, a process blower fault is generated. “PROC  
BLWR” is displayed on the relay screen. The alarm horn and light are activated.  
The process heater, regen heater, and process/regen blower are turned off. Pressing  
the ALARM RESET pushbutton will deactivate the alarm horn and light.  
Reset the motor overload and turn the Off-On-Start switch to the START position to  
restart the dryer.  
7. The valve position limit switch enables the right bed heater and provides an input  
signal to the programmable relay when actuated by the cam lobe. Each heater is ON-  
OFF controlled by the OMRON E5C2 controller.  
8. Upon completion of the HEAT portion of the regeneration sequence, the regen  
heaters are disabled by the programmable relay and the COOL time begins.  
9. Once the COOL time has expired, the valve motor is turned on until the cam switch  
makes a transition. Upon making a transition, the timing sequence is restarted for the  
new bed.  
10. When no fault conditions exist, the display reads “SYSTEM NORMAL”.  
11. When a dew point fault is generated by the optional dew point controller, the alarm  
horn and light will activate. The alarm light will flash, indicating a non-critical fault.  
Press Alarm Reset to deactivate the alarm until the next dew point fault occurs.  
12. The top 2 lines of the display show the HEAT and COOL times (in minutes) for the  
regeneration sequence. Changes to these times can be made by the operator as  
follows:  
a. Press the up or down arrow until the cursor is positioned at the number to be  
changed.  
b. Press the “+” key to increment the number, or the “-“ key to decrement the  
number.  
c. Press the “OK” key to accept the value and write to the relay memory.  
OR  
d. Press the “ESC” key to cancel the changes.  
Note: A change will NOT take effect until step 12-c is done.  
13. The dryer is shut off by turning the control power switch to the OFF position.  
14. Refer to Schematic drawing A0566087 enclosed in the control enclosure.  
Dehumidifying Dryers  
Chapter 4: Operation  
38 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alarm Display Messages  
Note: The relay screen which contains the Alarm Display Messages is located  
inside the controller enclosure.  
WARNING! Do not attempt to check the Alarms on the Controller located within the  
unit enclosure unless you are a qualified electrician!  
The following is a list of Alarm Display Messages which can be found on the relay screen:  
Temperature Controller Alarm and/or  
HIGH TEMP  
PROC BLWR  
Regen Heater Temp Switch and/or  
Process Heater Temp Switch and/or  
Redundant Temp Safety  
Blower Overload  
Valve Motor Time-Out  
Multiple Alarms  
No Alarms  
VALVE MTR  
PROC BLWR  
HIGH TEMP  
VALVE MTR  
HEAT  
35  
COOL  
30  
SYSTEM  
NORMAL  
Dehumidifying Dryers  
Chapter 4: Operation  
39 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-4 Auto-Tuning the Dryer  
1. For Auto-tuning, press the beige button once. The AT screen will show with the  
setting OFF.  
2. Press the UP arrow to change the setting to ON.  
3. Press the beige button again to go back to the Temperature Screen. Your actual  
temperature will start to flash for about 10-20 minutes with the temperature  
fluctuating up and down during that period. After the flashing stops, it means auto-  
tuning has finished.  
4-5 Shutting Down the Dryer  
1. Turn off the conveying system supplying the drying hopper.  
2. When processing is complete, close the hopper slide gate and shut down any in-line  
companion equipment, such as the aftercooler.  
3. Turn the Dryer ON/OFF selector switch to OFF.  
4. Turn the system ON/OFF switch to OFF.  
5. If needed, empty the drying hopper.  
6. For maintenance or a long term shutdown, open (de-energize) the electrical  
disconnects at the dryer and at the power drop.  
Dehumidifying Dryers  
Chapter 4: Operation  
40 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5: Maintenance  
5-1 Preventative Maintenance Schedule  
The checklist below contains a list of items which should be inspected and/or replaced to  
keep your Dehumidifying Dryer operating at peak efficiency. Perform each inspection at the  
regular intervals listed below.  
System model #  
Every week  
Serial #  
Date/ Date/ Date/ Date/ Date/ Date/ Date/ Date/ Date/ Date/ Date/ Date/ Date/  
By  
By  
By  
By  
By  
By  
By  
By  
By  
By  
By  
By  
By  
Inspect all filters for  
wear, replace/  
clean if dirty or  
worn.  
Check to make  
sure that all hose  
conections are  
air tight.  
Every month Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec  
Lock out electrical  
power and inspect  
electrical wiring for  
integrity.  
Lock out electrical  
power and check  
heater elements for  
continuity using an  
ohmmeter.  
Check dew point  
and temperature  
tracking with an  
external dew point  
monitor and  
pyrometer.  
Visually inspect the  
shifting of the  
airflow valve during  
one cycle.  
Next scheduled  
inspection  
Actual inspection  
Date/By  
Next scheduled  
inspection  
Actual inspection  
Date/By  
Every year  
Inspect desiccant. Replace  
if brown or broken.  
Scheduled  
replacement date  
Actual replacement  
Date/Work done by  
Scheduled  
replacement date  
Actual replacement  
Date/Work done by  
Every two years  
Replace desiccant.  
- Photocopy this page for your maintenance records -  
Dehumidifying Dryers  
Chapter 5: Maintenance  
41 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-2 Preventative Maintenance  
This section describes maintenance procedures which will increase the longevity and  
efficiency of your dehumidifying dryer. Perform them at the regular intervals listed on the  
dryer checklist on the previous page.  
Servicing Process Air Filters  
Caution!  
Operating the dryer without the process air filter installed voids your  
warranty!  
Filter cleaning is an important part of your dryer maintenance program.  
Dehumidifying dryers have a single cartridge canister-type filter in the process air loop. The  
filter protects blowers from plastic fines drawn in from the drying hopper and prevents the  
desiccant from being contaminated. Regular filter cleaning is essential to keep your dryer  
operating at peak efficiency.  
You can blow or vacuum the dirt out of the filter with compressed air, but remember, it could  
become damaged from high-pressure blowing.  
Recommendations for Cleaning and Replacing Filters  
Turn off and/or lock out electrical power to the dryer.  
Remove the threaded fastener securing the filter access cover, then remove the cover.  
Remove the nut on the center retaining rod to remove the filter cartridge.  
Figure 10: Air Filter Location and Disassembly  
Process Return  
Air Filter  
1" Wide x 1/8" Thick High  
Temperature Gasket  
Vacuuming  
Try vacuum-cleaning a soiled filter first. Vacuuming removes most large particles and  
surface contaminants, and may suffice for the first time you clean a filter. Use a commercial-  
duty (recommended) or household vacuum cleaner. Vacuum the filter from the air intake  
(dirty) side only.  
Dehumidifying Dryers  
Chapter 5: Maintenance  
42 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning with Compressed Air  
Blow clean, dry compressed air up and down the pleats, blowing out the filter  
from the inside out. Remove loose dirt from the filter with compressed air or  
vaccum from the outside.  
Caution!  
DO NOT clean/wash filter with water!  
After each cleaning:  
Inspect the filter element. Briefly hold a light bulb behind the element  
and look for any fatigued paper or residual dirt. Inspect for holes and  
tears by looking though the filter toward a bright light. Check for  
damaged gaskets or dented metal parts. Do not re-use a damaged  
filter!  
Check the gasket for damage. A damaged gasket allows contaminants  
into the process. Replace as needed.  
Figure ?: Cooling Coil Location and Disassembly  
1" Wide x 1/8" Thick High  
Temperature Gasket  
Use compressed air or a steam  
cleaner to blow the dust off or clean  
any oily residue on the coil.  
Undo (4) 10-32 Button  
Head Screws using 1/8  
Allen Wrench  
Note: To clean the cooling coil, use compressed air or a steam cleaner to blow the  
dust off or clean any oily residue on the coil.  
Servicing the Dew Point Monitor  
The accuracy of the dew point monitor on mini dryer systems depends on proper operation of  
the dew point sensor and the control board. The dew point sensor is in the process air stream  
and is therefore susceptible to contamination.  
Dehumidifying Dryers  
Chapter 5: Maintenance  
43 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dew point sensor life depends on:  
Air temperature and flow passing over the sensor.  
The amount of fines (dust) in the process air.  
The amount of plasticizer vapor in the process air.  
Once every six months, the dryer operator should monitor the initial dew point sensor  
readings and establish a periodic replacement schedule as needed.  
Caution!  
Do not attempt to check the continuity or resistance of the dew point  
sensor.  
The sensor will be destroyed!  
5-3 Corrective Maintenance  
This section provides you with the information necessary to correct or repair any issues  
which might appear during the normal operation of your dehumidifying dryer. Although we  
have listed how to perform these procedures, it is recommended that you call the Service  
Department to have any in-depth maintenance performed.  
Symptoms of Worn Desiccant  
The moisture absorption capacity of the desiccant used in your dehumidifying dryer degrades  
after an indefinite period of time. Useful life depends on variables such as material moisture  
content, plasticizer vapors in the return air, and number of regeneration cycles.  
Your dryer may need new desiccant if it exhibits any of the following symptoms:  
The process air dew point measured with a portable dew point monitor  
is higher than -10°F (-23ºC) throughout the process drying cycle.  
Noticeable amounts of desiccant in the beds is a medium-brown color  
or darker.  
If you notice any of these signs, replace the desiccant in the desiccant beds. Desiccant  
replacement kits are available from the Parts Department. If you want, a technician can  
repack desiccant beds at your site.  
Dehumidifying Dryers  
Chapter 5: Maintenance  
44 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING! Handling desiccant material is HAZARDOUS.  
Wear an N-100 type safety filter mask or equivalent to avoid prolonged  
breathing of desiccant dust. Wear safety goggles and gloves to avoid  
contact with eyes and skin.  
Handle with adequate ventilation.  
Wash hands thoroughly after handling.  
FIRST AID ✚  
In case of eye contact, immediately flush eyes  
with plenty of water for at least 15 minutes.  
SEE A PHYSICIAN IMMEDIATELY IF IRRITATION PERSISTS.  
Replacing Worn Desiccant  
Caution!  
DESICCANT BEDS ARE HOT DURING OPERATION.  
To avoid burn hazard, make sure desiccant beds are sufficiently cool  
before replacing worn desiccant.  
To access the Desiccant Bed:  
1. Disconnect electrical power to the dryer.  
2. Using a 1/8” Allen wrench, remove the four (4) 10-32 button head screws holding the  
Dessicant Cap to the Regeneration Heater.  
3. Remove the Desiccant Cap.  
4. With a shop vacuum, carefully remove all desiccant from each tower.  
Dehumidifying Dryers  
Chapter 5: Maintenance  
45 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 11: Desiccant Bed Location and Disassembly  
Undo (4) 10-32 Button  
Desiccant Cap  
Head Screws using 1/8  
Allen Wrench  
1" Wide x 1/8" Thick Silicon  
Strip and Stick Gasket  
13X Molecular Sieve  
8x12 Beads  
Regeneration Heater  
Regeneration  
Thermocouple  
16 Mesh 0.028 Diameter Wire  
Stainless Steel Screen  
(2) 4-40 screws  
Hi Temperature  
Snap Switch  
1" Wide x 1/8" Thick High  
Temperature Gasket  
Caution!  
You should properly dispose of any discarded desiccant.  
Consult local disposal regulations for more information.  
Inspect each lower desiccant screen for tears or holes where desiccant burned-through.  
Replace as needed.  
After cleaning each chamber, add a level layer of half the 8 x 12 bead desiccant on top of the  
screen. Next, carefully add the full amount of bead desiccant specified per bed. Amounts are  
listed in the Desiccant Amounts Table below. Smooth the top level, and finally add another  
layer of the remaining bead desiccant to the top. Make sure this layer is level and smooth.  
Repeat the previous step for the other bed.  
Inspect the gaskets on the valve assembly. Replace if necessary.  
Re-install the valve and reconnect actuator wiring.  
Figure 12: Required Desiccant Amounts  
Dryer  
8 x 12 bead Total  
model  
15 cfm  
30 cfm  
60 cfm  
Part no.  
lbs.  
4.75  
12.25  
27.5  
Kg  
2.15  
5.56  
12.5  
W00018051  
Dehumidifying Dryers  
Chapter 5: Maintenance  
46 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing the Process Heater  
The dehumidifying dryers utilize a single-phase Calrod-type heater element. This heater  
element is mounted in the center compartment below the desiccant beds. Although the  
replacement procedure is the same for each heater, the wattage varies by model, voltage,  
temperature range, etc.  
WARNING! Hazardous electrical current present.  
Disconnect and lock out power before you replace heater elements!  
Figure 13: Process Heater Location and Disassembly  
Undo (6) 10-32 Button  
Head Screws using 1/8  
Allen Wrench  
1" Wide x 1/8" Thick High  
Temperature Gasket  
(2) 4-40 screws  
Hi Temperature  
Snap Switch  
Procedures  
1. Remove the six (6) 10-32 button head screws securing the process heater access  
cover using a 1/8” Allen wrench.  
2. Sketch the heater wiring configuration so you can properly re-wire the heater.  
3. Remove the wires to the heater plate assembly being removed or replaced.  
4. Remove the two (2) 4-40 screws securing the heater plate assembly, and slide out the  
assembly.  
5. Remove the heater from the mounting plate by removing the large brass nuts and  
washers.  
6. Re-install the heater and heater plate assemblies in reverse order. Install new heater  
gaskets and securely tighten all fasteners.  
Caution!  
Heater loops should not touch each other.  
“Hot spots” lead to premature heater failure!  
7. Reinstall the wires based on the sketch you made earlier.  
Dehumidifying Dryers  
Chapter 5: Maintenance  
47 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6: Troubleshooting  
6-1 Introduction  
The utmost in safety precautions should be observed at all times when working on or around  
the machine and the electrical components. All normal trouble-shooting must be  
accomplished with the power off, line fuses removed, and with the machine tagged as out of  
service.  
The use of good quality test equipment cannot be over-emphasized when troubleshooting is  
indicated. Use a good ammeter that can measure at least twice the AC and DC current that  
can be encountered for the machine. Be sure that the voltmeter has at least minimum  
impedance of 5,000 OHMS-per-volt on AC and 20,000 OHMS-per-volt on DC scales.  
Popular combination meters, VOM and VTVM can be selected to provide the necessary  
functions.  
Before making haphazard substitutions and repairs when defective electrical components are  
malfunctioning, we recommend that you check the associated circuitry and assemblies for  
other defective devices. It is common to replace the obviously damaged component without  
actually locating the real cause of the trouble. Such hasty substitutions will only destroy the  
new component. Refer to wiring diagrams and schematics.  
Locating mechanical problems, should they occur, is relatively straightforward. When  
necessary, refer to the parts catalog section.  
Problem  
Possible cause  
Corrective action  
Dirty filter.  
Clean or replace filter.  
Desiccant beds are contaminated  
by material or plasticizer leaking  
into the system.  
Replace desiccant. See Page 42  
for more information.  
Little or no air coming from  
the process delivery tube.  
Fix the problem and reset the  
overload.  
Blower overload has tripped.  
Blower fins filled with dust or  
contaminants.  
Remove blower side plate,  
clean baffles, replace.  
Stop the dryer.  
If the dryer was connected to  
the drying hopper, check to see  
if the desiccant and process air  
heater has been contaminated  
with resin.  
If so, replace the desiccant and  
remove any resin carry-over.  
Otherwise, change the phase of  
two legs of the three-phase  
power drop.  
Suction in delivery tube,  
pressure from the return tube.  
Phase is reversed on power drop  
coming into the dryer.  
Dehumidifying Dryers  
Chapter 6: Troubleshooting  
48 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Possible cause  
Corrective action  
Check for open heaters. Replace  
if required.  
Process heaters are faulty.  
Solid-state temperature  
controller faulty.  
Replace.  
Loss or reduction of process air  
temperature.  
Make sure that plant personnel  
are aware of the proper  
temperature set point. Post an  
appropriate sign next to the  
controller.  
Process temperature was  
adjusted in error by plant  
personnel.  
Process heaters are faulty.  
Desiccant beds are  
contaminated.  
Replace.  
Replace desiccant.  
Drying systems are designed for  
the material which was  
originally specified. Different  
materials may need a longer  
residence time or a different  
drying temperature.  
Material being dried differs  
from material specified at the  
time of purchase.  
Loss or reduction in drying  
capacity.  
Break in flex hose to/from  
drying hopper.  
Inspect for air leaks; replace as  
needed.  
Check for proper operation of  
valve actuators. Repair or  
replace if necessary.  
Airflow valve sticking or failing  
to shift.  
Remove blower side plate,  
clean baffles, replace.  
Replace filter elements.  
Check power supply and power  
wiring to PLC.  
Blower fins filled with dust or  
contaminants.  
Insufficient power to PLC  
(Power LED is off).  
PLC Regeneration Bed LED  
indicators both off.  
Faulty PLC (PLC Power light is  
on, Run light is off, and/or Error Replace PLC.  
light is on).  
Regenerating bed cooldown.  
None.  
Verify that blower contactor is  
on. Check input wiring to PLC.  
Blower Input indicator is off.  
Process air in high-temperature  
condition.  
Insufficient power to PLC  
(Power light is off).  
PLC Regeneration Heater  
Left/Right output indicators both  
off.  
None.  
Check power supply and power  
wiring to PLC.  
Faulty PLC (PLC Power light is  
on, Run light is off, and/or Error Replace PLC.  
light is on).  
Dehumidifying Dryers  
Chapter 6: Troubleshooting  
49 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Possible cause  
Corrective action  
Check resin manufacturer’s data  
sheet for proper drying  
Process temperature set too high temperature. Make sure plant  
due to operator error.  
personnel are aware of the  
correct process temperature set  
point.  
High temperature alarm not set  
properly.  
Process set point is out of  
acceptable range.  
Reset high temperature alarm.  
Material in drying hopper cakes,  
or meltdown occurs.  
Restore temperature controller  
to factory pre-sets.  
Function set for degrees Celsius  
(ºC), set point at degrees  
Fahrenheit (ºF).  
Verify correct Celsius or  
Fahrenheit settings.  
Verify that the thermocouple is  
properly installed in the inlet  
tube.  
Process thermocouple not in  
airflow.  
Burned out regeneration heater.  
Contaminated or worn out  
desiccant.  
Repair or replace.  
Replace.  
Leaking process air hoses.  
Dryer operates beyond its  
capacity.  
Repair or replace.  
Check dryer and drying hopper  
sizing.  
Poor dew point performance.  
Bad dew point sensor.  
Fouled dew point sensor  
manifold.  
Replace.  
Clear obstruction. Air should  
flow freely through sensor.  
Clean or replace filter element.  
Dirty filter.  
The internal mechanism is not  
inserted properly into the  
housing.  
Properly insert the internal  
mechanism into the housing.  
The power supply is not  
connected to its terminals  
properly.  
No power is supplied, or the  
supplied power is not within the VAC to the power supply  
Properly connect the power  
supply to the power supply  
terminals.  
Nothing displays when the  
controller is turned on.  
Supply a voltage of 85 to 125  
specified range.  
terminals of the controller.  
Check control power fuse for  
continuity. Turn disconnect  
switch and control power switch  
ON.  
Disconnect switch or Control  
Power switch not set to ON.  
Control Power fuse blown.  
Dehumidifying Dryers  
Chapter 6: Troubleshooting  
50 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Possible cause  
Corrective action  
No setting change possible on  
temperature controller.  
The key protection switch is set  
to ON.  
Set the key protection switch to  
OFF.  
Input polarity on thermo-couple  
is wrong or connection is wrong.  
Properly wire the terminals.  
Properly set the input with the  
input-type selector rotary  
switch.  
Input-type setting is incorrect.  
No compensating lead wires  
used for extension of the  
thermocouple.  
Use proper compensating lead  
wires and terminals.  
Use a dedicated thermocouple  
Thermocouple and controller are connector. If a connector is a  
connected by wires other than  
proper lead wires.  
metal different from the  
thermocouple and controller, a  
temperature error may result.  
Verify that the thermocouple is  
properly installed in the inlet  
tube.  
Process value is abnormal or  
not obtained.  
Process thermocouple not in  
airflow.  
Sensor is broken or short-  
circuited.  
Replace with a good sensor.  
Separate input wires as far as  
possible from the origin of the  
noise.  
The controller is influenced by  
noise or other induction.  
Check Mode selector switch 6:  
Celsius temperatures used  
instead of Fahrenheit or vice  
versa.  
Process value shifted because  
the input shift function is used.  
ON - ºF  
OFF - ºC  
Set input shift value to 0, or set  
mode selector switch 4 to OFF.  
6-2 Determining Temperature Controller Errors or Sensor Errors  
Using a Thermocouple  
If the controller displays a temperature that is close to room temperature (70ºF/21ºC) when  
you short-circuit controller input terminals, the controller is normal and the sensor is probably  
broken, short-circuited, or incorrectly wired.  
Using a Platinum Resistance Thermometer  
If the controller displays a temperature of about 0.0°C (32ºF) when you insert a 100-ohm  
resistor between terminals A and –B of the controller, and you short-circuit controller  
terminals +B and –B, the controller is normal and the sensor is probably broken, short-  
circuited, or incorrectly wired.  
Other service problems or questions can be answered by contacting the Service  
Department.  
Dehumidifying Dryers  
Chapter 6: Troubleshooting  
51 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7: Appendix  
7-1 Warranty  
Unless otherwise specified, this product includes a Standard ONE YEAR PARTS  
WARRANTY.  
Warranty Specifications  
The manufacturer hereby expressly warrants all equipment manufactured by it to be free from  
defects in workmanship and material when used under recommended conditions, as set forth  
in the operating manuals for such equipment. THE FOREGOING EXPRESS WARRANTY  
IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, GUARANTIEES,  
AGREEMENTS, AND SIMILAR OBLIGATIONS OF THE COMPANY AND/OR  
MANUFACTURER (UNLESS OTHERWISE SPECIFIED IN THE SPECIFIC PRICE  
PAGE OR LIMITED BY THE MANUFACTURERS’ WARRANTY FOR PARTS). The  
Company’s obligation is limited to repair or replace FOB the factory any parts that are  
returned, prepaid, within one year of equipment shipment to the original purchaser, and  
which in the Company’s opinion, are defective. Any replacement part assumes the unused  
portion of this warranty.  
Warranty Restrictions  
This parts warranty does not cover any labor charges for replacement of parts, adjustment  
repairs, or any other work. This warranty does not apply to any equipment which, in the  
Company’s opinion, has been subjected to misuse, negligence, or operation in excess of  
recommended limits, including freezing or which has been repaired or altered without the  
Company’s express authorization. If the serial number has been defaced or removed from the  
component, the warranty on that component is void. Defective parts become the property of  
the warrantor and are to be returned immediately, without any further use or handling.  
Dehumidifying Dryers  
Chapter 7: Appendix  
52 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty Liabilities  
THE COMPANY EXPRESSLY DISCLAIMS ANY AND ALL LIABILITY FOR ANY  
SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR EXPENSES THAT  
RESULT FROM THE USE OF THIS PRODUCT. Some states do not allow the exclusion or  
limitation of special, consequential or incidental damages, so the above limitation may not  
apply to you. The Company’s obligation for parts not furnished as components of its  
manufactured equipment is limited to the warranty of the manufacturers of said parts. The  
company neither assumes nor authorizes any other persons to assume for it any liability in  
connection with the sale of its equipment not expressed in this warranty. No person, agent,  
manufacturer, distributor, dealer, installer or company is authorized to change, modify or  
extend the terms of this warranty in any manner whatsoever.  
The time within which an action must be commenced to enforce any obligation of the  
Company’s arising under this warranty, or under any statute or law of the United States or  
any state thereof, is hereby limited to the duration of this warranty. Some states do not permit  
this limitation, so the above may not apply to you. This warranty gives you specific legal  
rights and you may also have other rights which vary from state to state. For transactions  
involving the potential applicability of international law or that of a foreign country,  
this warranty policy and the procedures hereunder shall be governed by  
applicable federal and state law, but not by the United Nations Convention on Contracts for  
the Sale of Goods.  
Customer Responsibilities  
Any sales, use, or other tax incident to the replacement of parts under this warranty is the  
responsibility of the purchaser.  
7-2 Optional Components  
The following is a list of options which your Dehumidifying Dryer may have been equipped  
with:  
Dew Point Monitor  
Audible Alarm with Silence Button  
High Temperature Option (with Aftercooler)  
Casters  
AP1 PLC Control System  
Dehumidifying Dryers  
Chapter 7: Appendix  
53 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-3 Technical Specifications  
Annex B Information  
The following design information is provided for your reference:  
1. No modifications are allowed to this equipment that could alter the CE compliance  
2. Ambient temperature:  
3. Humidity range:  
4. Altitude:  
0 degrees Celsius – Maximum (104 degrees Fahrenheit)  
50% relative humidity  
Sea level  
5. Environment:  
6. Radiation:  
Clean, dust-free and non-explosive  
None  
7. Vibration:  
Minimal, i.e. machine mounting  
8. Allowable voltage fluctuation:  
9. Allowable frequency fluctuation:  
+/- 10%  
Continuous  
Intermittent  
+/- 1%  
+/- 2%  
10. Nominal supply voltage:  
460/3/60 (Verify on serial number tag)  
11. Earth ground type: TN (system has one point directly earthed through a protective  
conductor)  
12. Power supply should include a ground connection.  
13. Over-current protection is supplied in the dryer, but additional protection should be  
supplied by the user.  
14. The door-mounted disconnect serves as the electrical disconnect device.  
15. Dryer is not equipped with local lighting.  
16. Functional identification  
17. Dryer is equipped with a CE mark  
18. Dryer is supplied with an operating manual in the language of the destination  
country.  
19. Cable support may be required for power cord, depending on final installation.  
20. No one is required to be in the interior of the electrical enclosure during the normal  
operation of the unit. Only skilled electricians should be inside the enclosure for  
maintenance.  
21. Doors can be opened with a screwdriver, but no keys are required.  
22. Two-hand control is not required or provided.  
23. All dryers should be moved around and set in a place with a lift truck or equivalent.  
24. There are no frequent repetitive cycles that require manual controlrepetitive  
functions are automatic while the dryer is operating.  
25. An inspection report detailing the functional test is included with the dryer.  
26. The machine is not equipped with cableless controls.  
27. Color-coded (harmonized) power cord is sufficient for proper installation.  
Dehumidifying Dryers  
Chapter 7: Appendix  
54 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Aftercooler Design Specifications  
Entering water temp.  
ºF  
ºC  
85ºF  
29ºC  
7-4 Drawings and Diagrams  
7-5 Spare Parts List  
Figure 18: Level 1 Spare Parts List (Electrical & Mechanical)  
MINI DRYER SPARE PARTS LIST AD15, AD30, AD60  
LEVEL 1 ( Electrical Components )  
PART #  
SIZE Description  
A0568932  
A0568933  
A0568934  
A0534039  
A0534040  
A0534041  
A0534042  
A0534043  
A0534044  
A0534046  
A0534047  
A0534048  
A0534049  
A0568936  
A0434051  
A0568909  
A0568910  
A0568911  
A0534804  
A0568917  
A0550577  
A0568919  
A0568921  
A0550593  
A0538062  
A0568922  
A0568923  
A0568926  
A0538069  
A0536892  
A0536894  
A0536895  
A0538001  
A0538002  
A0568941  
A0558078  
A0558079  
A0558082  
2
Fuse for the Heater Elements  
3
2.5 Fuse for the Heater Elements  
3
3.5 Fuse for the Heater Elements  
4
5
6
7
8
10 Fuse for the Heater Elements  
12 Fuse for the Heater Elements  
15 Fuse for the Heater Elements  
20 Fuse for the Heater Elements  
25 Fuse for the Heater Elements  
30 Fuse for the Heater Elements  
3
3
3
3
Fuse for the Heater Elements  
3
3
3
3
Fuse for the Heater Elements  
Fuse for the Heater Elements  
Fuse for the Heater Elements  
Fuse for the Heater Elements  
Fuse for the Heater Elements  
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
Fuse for the Process Blower  
3
1.125 Fuse for the Process Blower  
1.25 Fuse for the Process Blower  
3
3
2
Fuse for the Process Blower  
2.5 Fuse for the Process Blower  
Fuse for the Process Blower  
3
3
3
3
3
3.2 Fuse for the Process Blower  
4.5 Fuse for the Process Blower  
5.6 Fuse for the Process Blower  
3
3
2
1
3
3
6
Fuse for the Process Blower  
6.25 Fuse for the Process Blower  
Fuse for the Process Blower  
3
2
1
3
7
3
10 Fuse for the Process Blower  
12 Fuse for the Process Blower  
1.25 Fuse for the transformer  
1.6 Fuse for the transformer  
1.8 Fuse for the transformer  
3.2 Fuse for the transformer  
3.5 Fuse for the transformer  
2.8 Fuse for the transformer  
0.3-1 Motor Overload  
3
2
1
3
3
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
2
1
2
1
2
1
2
2
1
2
1
1 (ALL)  
1-2.9 Motor Overload  
1.6-5 Motor Overload  
1
1
1
LEVEL 1 ( Mechanical Components )  
PART #  
SIZE Description  
W00015435  
1
1
1
1
1
1
1
1
1
1
1
1
Dew Point Sensor Insert Cable
A0548556  
A0566467  
A0566531  
W00018051  
W00013983  
A0566676  
Dew Point Sensor  
Valve switch  
Process Air Filter  
13X molecular Sieve Desiccant ( 8 X 12 Beads )  
High Temperature Gasket.  
4.75 Lbs.  
135 Inches  
12.25 Lbs.  
163 Inches  
3
27.5 Lbs.  
188 Inches  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Temperature Snap Switch.  
3
Figure 19: Level 2 & 3 Spare Parts List (Electrical & Mechanical)  
MINI DRYER SPARE PARTS LIST AD15, AD30, AD60  
LEVEL 2 ( Electrical Components )  
PART #  
SIZE Description  
Motor Starter  
A0558000  
A0530042  
A0567917  
A0544089  
A0558065  
A0548555  
A0505417  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Mercury Heater Contactor  
Process Air Temperature Controller  
Regeneration Air Temperature Controller  
Dew Point Monitor  
*
*
Dew Point Circuit Board  
Regeneration T'Couple Relay  
LEVEL 2 ( Mechanical Components )  
PART #  
SIZE  
Description  
A0548621  
A0566478  
A0566479  
A0566480  
A0566481  
A0566482  
A0566483  
A0566484  
A0566485  
A0566486  
A0566487  
A0566601  
A0566602  
A0566603  
A0566604  
A0566605  
A0568139  
A0568140  
A0568141  
A0566682  
A0566415  
Ceramic Cap for the End of Heater Elements  
750 Watts Heater element 208/220 Volts  
750 Watts Heater element 230 Volts  
750 Watts Heater element 400 Volts  
750 Watts Heater element 460 Volts  
750 Watts Heater element 575 Volts  
1250 Watts Heater Element 208/220 Volts  
1250 Watts Heater Element 230 Volts  
1250 Watts Heater Element 400 Volts  
1250 Watts Heater Element 460 Volts  
1250 Watts Heater Element 575 Volts  
2500 Watts Heater Element 208/220 Volts  
2500 Watts Heater Element 230 Volts  
2500 Watts Heater Element 400 Volts  
2500 Watts Heater Element 460 Volts  
2500 Watts Heater Element 575 Volts  
Screen Cover for the Desiccant Tanks  
Screen Cover for the Desiccant Tanks  
Screen Cover for the Desiccant Tanks  
1/4" OD Teflon Tube.  
4
5
0
0
0
0
0
7
0
0
0
0
0
2
2
2
2
2
2
2
2
2
2
2
2
5
5
4
3
4
3
5
4
5
4
3
5
4
3
5
4
3
0
0
0
0
0
0
0
0
0
0
2
3
2
2
5 Feet  
8
5 Feet  
10  
5 Feet  
14  
Washer / Gasket for the Heater Elements  
MINI DRYER SPARE PARTS LIST AD15, AD30, AD60  
LEVEL 3 ( Electrical Components )  
PART #  
SIZE  
Description  
A0567921  
A0566096  
A0568961  
Power Disconnect  
Mitsubishi Programmable Relay Logic Controller  
Redundant Temperature Safety Controller  
1
1
1
1
1
1
1
1
1
LEVEL 3 ( Mechanical Components )  
PART #  
SIZE  
Description  
2" O.D. by 12 Ft Long Hi Temp Hose.  
2-1/2" O.D. by 12 Ft Long Hi Temp Hose.  
Return Air Cooling Coil  
208/460 Volt Process Blower.  
575 Volt Process Blower  
208/460 Volt Process Blower.  
575 Volt Process Blower  
208/460 Volt Process Blower.  
575 Volt Process Blower  
A0534059  
A0534060  
A0566535  
A0536628  
A0536629  
A0534079  
A0535351  
A0552439  
A0552440  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Dehumidifying Dryers  
Chapter 7: Appendix  
56 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-6 Returned Material Policy  
Credit Returns  
Prior to the return of any material authorization must be given by the manufacturer. A  
RMA number will be assigned for the equipment to be returned.  
Reason for requesting the return must be given.  
ALL returned material purchased from the manufacturer returned is subject to 15% ($75.00  
minimum) restocking charge.  
ALL returns are to be shipped prepaid.  
The invoice number and date or purchase order number and date must be supplied.  
No credit will be issued for material that is not within the manufacturer’s warranty period  
and/or in new and unused condition, suitable for resale.  
Warranty Returns  
Prior to the return of any material, authorization must be given by the manufacturer. A  
RMA number will be assigned for the equipment to be returned.  
Reason for requesting the return must be given.  
All returns are to be shipped prepaid.  
The invoice number and date or purchase order number and date must be supplied.  
After inspecting the material, a replacement or credit will be given, at the manufacturer’s  
discretion. If the item is found to be defective in materials or workmanship, and it was  
manufactured by our company, purchased components are covered under their specific  
warranty terms.  
7-7 Safety Tag Information  
Dryer Safety Tags  
Hot!  
Read Operation  
and Installation  
Manual  
High Voltage  
Earth Ground  
Inside Enclosure  
PE Protected Earth  
Ground  
Lifting Point  
Dehumidifying Dryers  
Chapter 7: Appendix  
57 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-8 Dryer Identification (Serial Number) Tag  
(Located on back of Dryer)  
Company Logo  
XXX Series Dryer  
Model Number XXX-15  
Max Drying Capacity HR  
460V  
1Ǿ  
Serial Number 060701R  
Date of Manufacture 06/2003  
4.5A  
Over-current Protection Device (s) 4.5A Total  
Frequency 50/60Hz  
Compressed air supply None  
Dryer Mass 400 lbs/(180 KG)  
Electrical Diagrams &  
Pneumatic Diagram  
Street Address  
City, State Zip Code  
Telephone Number  
Dehumidifying Dryers  
Chapter 7: Appendix  
58 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-9 Technical Assistance  
Parts Department  
[
]
[
]
Call toll-free 7am–5pm CST 800 423-3183 or call 630 595-1060, Fax [630] 475-7005  
The ACS Customer Service Group will provide your company with genuine OEM quality parts  
manufactured to engineering design specifications, which will maximize your equipment’s performance  
and efficiency. To assist in expediting your phone or fax order, please have the model and serial  
number of your unit when you contact us. A customer replacement parts list is included in this manual  
for your convenience. ACS welcomes inquiries on all your parts needs and is dedicated to providing  
excellent customer service.  
Service Department  
[
]
[
]
Call toll-free 8am–5pm CST 800 233-4819 or call 630 595-1060  
[
]
Emergencies after 5pm CST, call 847 439-5655  
We have a qualified service department ready to help. Service contracts are available for most  
products.  
Sales Department  
[
]
Call 630 595-1060 Monday–Friday, 8am–5pm CST  
Our products are sold by a world-wide network of independent sales representatives. Contact our Sales  
Department for the name of the sales representative nearest you.  
Contract Department  
[
]
Call 630 595-1060 Monday–Friday, 8am–5pm CST  
Let us install your system. The Contract Department offers any or all of these services: project planning;  
system packages including drawings; equipment, labor, and construction materials; and union or non-  
union installations.  
Dehumidifying Dryers  
Chapter 7: Appendix  
59 of 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp MP3 Docking Station DK CL66N User Manual
Sharp Refrigerator SJ F624ST User Manual
Shindaiwa Trimmer 68800 94313 User Manual
Silex technology Printer C 6100U User Manual
Sony Handheld Game System SCPH 75008 User Manual
Sony Home Theater System DAV DZ300 User Manual
Sony Personal Computer V G N C S 2 0 0 User Manual
Sony Projector VPL SC50U User Manual
SOYO Computer Hardware SY 5EMA+ User Manual
Swann Home Security System DB 815 User Manual