State Industries Electric Heater SDV100 199 User Manual

NEW!  
Non-Condensing  
Up To 85%  
Thermal  
SDV100-400  
Efficiency  
Commercial Gas Water Heater  
The Sandblaster® Forcedelivers the money-saving performance of State  
Industries original Sandblaster commercial water heater, plus a solution to  
negative air pressure, a problem found in many commercial applications.  
For example, in restaurant kitchens, commercial range hoods and exhaust fans  
draw large amounts of air out of the room. This creates negative air pressure in  
the room, which can deprive an ordinary commercial gas water heater of  
sufficient make-up air required for safe, efficient, proper operation.  
Exhaust pipe  
power-vents  
products of  
combustion to  
outside building.  
In negative air pressure situations, downdrafts can occur inside an ordinary  
water heater, compressing the burner flame, resulting in impaired water heating  
performance and recovery efficiency. Negative air pressure can also generate  
Carbon Monoxide buildup, and other potential safety hazards.  
Sandblaster® Forceis the solution, because it doesn’t share the inside air! It is  
equipped with a factory-installed blower and two-pipe system for intake of  
make-up air and separate exhaust venting. This unique air delivery system  
(patent pending) insures that Sandblaster® Forceis immune to negative air  
pressure. Sandblaster® Forcealso helps reduce space heating or air  
conditioning costs, because it does not consume heated or cooled air from  
inside the building.  
Air intake pipe  
draws all  
combustion  
make-up air  
from outside  
building.  
Long Vent Runs Mean Installation Flexibility  
The Forceinstalls just about anywhere, thanks to intake and exhaust vent runs  
of up to 135 feet horizontally or vertically on models SDV80-140, SDV100-199  
and SDV100-260. The SDV75-70 vent run is 50 feet horizontally or vertically.  
The SDV100-400 has a maximum vent run of 110 feet using 6 inch pipe. (Note:  
The first 10 feet of exhaust run for the SDV100-400 must be CPVC Schedule 40  
pipe minimum.) See the vent run chart or the owners manual for specific  
venting information.  
I
I
3-Year or 5-Year Tank Warranty.  
ASME Construction available on SDV100 260 and SDV100-400.  
Intermittent electronic ignition.  
Reinforced tank design for longer life – The Sandblaster® Force™  
I
I
I
glasslined tank is reinforced with extra steel in all the most critical areas, to  
insure long tank life.  
Turbo-Force Ring Self-Cleaning Feature – Patented design  
automatically reduces harmful sediment buildup inside the tank.  
Sandblaster® Forcestays energy-efficient, so it saves money throughout  
its life. Turbo-Force dip tube in model SDV75 70.  
Labor Replacement Allowance (LRA) for installing contractor if  
heater needs replacement during basic 3-year warranty: $250 LRA on  
75-70 model; $500 LRA on 80-140 and 100-199 models; $1000 LRA on  
100-260 and 100-400 models.  
Non-Condensing Design helps prevent corrosion. No condensate pump  
or drain needed.  
Installs with 3˝, 4˝ or 6˝ ** Schedule 40 PVC pipe, depending on the  
model and vent run.  
I
Removable lanced-port steel burner, with multiple tubular construction,  
for even heat distribution, maximum efficiency, quiet operation. SDV75 70 has  
a formed aluminized steel burner.  
Foam insulation – Reduces heat loss over 212 times more effectively than  
standard fiberglass.  
I
I
I
Factory-installed Temperature & Pressure safety valve (T&P Valve).  
Factory-installed Energy Cut-Off (“ECO”) safety switch.  
Multiple Magnesium Anode Rods – for extra protection against electrolytic  
tank corrosion. SDV75 70 has a single large diameter magnesium anode.  
I
I
I
I
I
I
Two 45° 3˝ or 4˝ (depending on model) Schedule 40 Elbows, with  
screen, supplied for use as vent caps. Schedule 80 Elbows on 100-400.  
Integral Automatic Blower – With 110/120 Volt electrical system. Maximum  
electrical draw: 2 Amps on SDV75 70, 12 AMPS on all other models.  
I
Tank Inspection Port for easy access to tank interior on all models  
except SDV75 70.  
I
Maximum Hydrostatic Working Pressure: 150 psi. (ASME 160 psi.)  
* Check owners manual and local codes for specific venting requirements. Each 90° elbow reduces  
maximum run by 5 feet.  
**Exhaust vent run on SDV100-400 must be CPVC Schedule 40 minimum for the first 10 feet of the run.  
The  
Expert’s  
WATER HEATERS 500 Lindahl Parkway, Ashland City,TN 37015  
Choice  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Server Technology Switch CDU CW 24VD User Manual
Snell Acoustics Speaker System IW SR7 User Manual
Sony Camcorder HXR MC1P User Manual
Sony Car Stereo System XR CA305 User Manual
Sony DVD Player DAV DZ119 User Manual
Spirit Treadmill XT385 User Manual
SPX Cooling Technologies Humidifier Evaporative Cooling User Manual
Sunrise Medical Mobility Aid HPL600 User Manual
Sylvania Automobile A0171 User Manual
Sylvania DVD Player SDVD8716D User Manual