Table of Contents  
Product Overview ..................................................................................1  
DIN Rail Mounting..................................................................................................................................... 2  
Load Default Settings / System Reset Button................................................................................. 2  
LED Indicators............................................................................................................................................. 2  
RJ45 Ethernet Pin Assignments ........................................................................................................... 3  
RS-232 DB9 Male Pin Assignment....................................................................................................... 3  
Introduction............................................................................................4  
Packaging Contents ................................................................................................................................. 4  
Installation ..............................................................................................4  
Web Browser Method.............................................................................................................................. 4  
Virtual COM Port Application................................................................................................................ 4  
Broadcast Search....................................................................................................................................... 5  
Web Console Operation.......................................................................................................................... 6  
Administrator.............................................................................................................................................. 6  
Authentication........................................................................................................................................... 6  
System IP...................................................................................................................................................... 7  
System Status ............................................................................................................................................. 7  
Load default setting................................................................................................................................. 8  
Firmware update....................................................................................................................................... 8  
TCP Mode..................................................................................................................................................... 9  
Telnet Server / Client................................................................................................................................ 9  
UART .............................................................................................................................................................. 12  
Virtual COM Software Operation......................................................................................................... 14  
COM Mapping............................................................................................................................................ 15  
TCP/UDP....................................................................................................................................................... 15  
Instruction Manual  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Applications.............................................................................17  
UDP ................................................................................................................................................................ 17  
TCP.................................................................................................................................................................. 17  
Specifications..........................................................................................18  
Technical Support ..................................................................................19  
Warranty Information............................................................................19  
Instruction Manual  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Overview  
Top View  
DIN rail screw hole  
Wall-mount screw hole  
Front View  
RS-232 DB9 male  
serial port  
Rear View  
RJ45 10/100M  
Ethernet port  
DC Jack  
Load Default/Reset  
Button  
Instruction Manual  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIN Rail Mounting  
Attach the included DIN Rail brackets (one per side) using the provided screws to the  
top DIN Rail screw hole (marked in the above diagram), and clip to your DIN Rail  
Load Default Settings / System Reset Button  
Load Default Settings  
Press and hold this button for more than 3 seconds, then release to load the factory  
default settings.  
IP address: 10.1.1.1  
Subnet Mask: 255.0.0.0  
Login ID / Password: admin  
System Reset  
Press and hold this button for more than 10 seconds, then release to reboot the device  
(maintains configuration settings)  
LED Indicators  
LED Name  
Status  
On  
Description  
Power is on and the device is ready.  
Power is off or the device is not ready.  
UTP is link.  
Ready  
Off  
On  
Link/Act  
Tx/Rx  
Blinking  
Off  
UTP Tx/Rx is activity.  
UTP is not link.  
RS-232 port is transmitting or receiving  
data.  
Blinking  
Off  
No data is transmitting or receiving in  
RS-232 port.  
Instruction Manual  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
RJ45 Ethernet Pin Assignments  
Pin  
1
2
3
6
TX+  
TX-  
RX+  
RX-  
RS-232 DB9 Male Pin Assignment  
NOTE: This serial device server performs as a DTE device.  
Pin  
1
Name  
DCD  
RD  
I/O  
Input  
2
Input  
3
TD  
Output  
Output  
4
DTR  
5
GND  
6
DSR  
RTS  
CTS  
Input  
Output  
Input  
7
8
Instruction Manual  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Packaging Contents  
1 x Serial over IP Device Server  
1 x Universal Power Adapter (NA/UK/EU)  
1 x Software CD  
1 x Instruction Manual  
1 x DIN Rail Kit  
Installation  
Web Browser Method  
1. Plug in the power adapter and connect the RJ45 interface to your LAN.  
NOTE: Alternatively, you can also use a crossover cable to connect the NETRS2321P  
directly to your system for the initial configuration.  
2. Press and hold the load default button for more than 3 seconds and less than 10  
seconds, then release it. This will return the serial device server to factory default  
and it will respond to the IP address 10.1.1.1.  
3. Configure the PC to the same IP domain.  
4. Open a web browser and connect to http://10.1.1.1 to open the configuration  
interface. The default login ID will be “adminand the password will be “admin.  
5. Once logged in, you will have access to all configuration settings including the  
ability to change the IP address for the device server.  
Virtual COM Port Application  
1. Plug in the power adapter and connect the RJ45 interface to your LAN.  
2. Insert the included CD and launch the VirtualCom software.  
3. Follow the on-screen instructions to install VirtualCom and WinPcap.  
4. Once installed, double-click the VCOM shortcut to launch the  
application.  
5. Click the Search button in the VCOM software window to locate the device.  
NOTE: You may receive a firewall notification at this point of the install, please allow  
access to this application  
Instruction Manual  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Broadcast Search  
The Broadcast Search function is used to locate all NETRS2321P devices that are  
connected to the same LAN as your computer. Since the Broadcast Search function  
searches by MAC address and not IP address, all NETRS2321P connected to the LAN  
will be located, regardless of whether or not they are part of the same subnet as  
the host.  
NOTE: Broadcast packet packets are not passed through a router. The VCom utility can  
only be used to monitor devices in the same segment of the LAN.  
NETRS2321P  
Instruction Manual  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web Console Operation  
Enter the IP address you have set for the  
NETRS2321P device into your web browser  
address bar (default IP: 10.1.1.1) and you will  
prompted to login with your user ID and  
password (Default: admin/admin).  
After a successful login, you will see Administrator,  
TCP Mode, UDP Mode, UART, and Reset Device  
selections in left frame of the web console - the  
following sections will describe their function.  
Administrator  
Under the ‘Administratorheading, you will be able to set/change the device password,  
configure the networking parameters, display the current firmware version, load the  
factory defaults, and perform any future firmware upgrades.  
Authentication  
In this page, you can change login ID and Password. The NETRS2321P device supports  
a maximum of 15 characters for password, only alphanumeric characters are allowed  
(“0-9,a-z,”A-Z”).  
Press “Updateto store the data. Reset the device to take effect.  
Instruction Manual  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
System IP  
On this page, you can adjust the NETRS2321P network configuration. If set to DHCP  
mode, all other settings will be ignored, and the IP address will be assigned by DHCP  
server after resetting the device.  
Press “Updateto store the data. Reset the device to take effect.  
System Status  
On this page, you can display the system Kernel firmware version and MAC Address.  
You can also adjust the device alias (Target Name) and Idle timeout settings. The Target  
Name field allows a Max of 12 characters, including “0-9,a-z,”A-Z,_(underscore),and  
“-(dash).  
NETRS2321P  
Press “Updateto store the ‘Target Namedata, and then, NETRS2321P will reset to  
take effect.  
Instruction Manual  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Load default setting  
On this page, you can load and store the factory default settings into EEPROM.  
NOTE: Network settings and MAC address will not be changed.  
Press “Loadto load default settings. Reset the device to take effect.  
Firmware update  
On this page, you can update the firmware via Ethernet.  
WARNING! Pressing the ‘Load’ button will immediately erase the flash with no  
further warning  
1. Pressing the “Loadbutton will erase flash.  
2. Wait for erase process to complete.  
3. There are two methods to do the Firmware Update action (TFTP or Web):  
NOTE: Please avoid loss of network connection, power or other interruption during  
the firmware upgrade procedure  
Web  
a. Please type in or browse the target image file in the input field, and then press  
“updatebutton to continue.  
TFTP  
a. Use Windows Command Prompt window to run the tftp client program.  
Syntax: tftp -i 10.1.1.1 put FILE_DIRECTORY\FILENAME.bin  
b. The firmware update should take about 45 seconds to complete.  
c. If the update process somehow goes wrong (like power failure), please connect  
device first)  
Instruction Manual  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
TCP Mode  
NOTE: When TCP mode is set to Server or Client mode, the UDP mode will be  
disabled automatically. When UDP mode is enabled, the TCP mode will be disabled  
automatically.  
Once you have completed making changes, press "Update" to store the data. Reset the  
device to take effect.  
Telnet Server / Client  
Set the device to be a Telnet Server. In server mode, the Telnet port listens and waits  
for a host or other client to make a connection. In this case the Ethernet connected  
device is the client.  
Set the device to be a Telnet Client. In the case the Ethernet connected device is the  
Telnet server or other NETRS2321P in server mode.  
Instruction Manual  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reverse Telnet  
Reverse Telnet works the same as Telnet Server mode. The Telnet port is listens for  
a connection after booting up. If you encounter errors when using some Telnet  
clients, such as the Microsoft interpretation of Telnet for Windows XP you can try the  
connection using Reverse Telnet mode.  
CLI Mode  
The Command Line Interface (CLI) allows user to configure and control NETRS2321P  
directly through the UART interface.  
NOTE: CLI mode is only available when NETRS2321P is in TCP Server Mode.  
Port Number  
This assigns the TCP server port number that the server will listen on for connecting  
clients. (Only for TCP Server Mode)  
Remote Server IP Address  
When in Client mode, this device will automatically try to connect to the remote TCP  
server with this IP address.  
Client mode inactive timeout  
When in Client mode, this parameter sets the time that device will maintain a  
connection until timeout, if there is no data transfer over the connection. After  
disconnecting, the device will try to build a new connection again immediately.  
Server mode protect timeout  
When in Server mode, this parameter sets the time that device will maintain a  
connection until timeout, if there is no data transfer over the connection. Once  
disconnected, only a Client can initiate a new connection to the Server.  
Instruction Manual  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UDP Mode  
When UDP mode is enabled, TCP mode will be disabled automatically. In UDP mode,  
the Local Port will be assigned to this device. You can list the remote connection IP and  
Port for up to 10 remote devices.  
Once you have completed making changes, press "Update" to store the data. Reset the  
device to take effect.  
Mode  
Listen: When in UDP Listen mode, it can only receive remote UDP data.  
Normal: When in UDP Normal mode, it can both receive and send UDP data to  
remote units.  
Local Port  
Assign the UDP port that this unit listens on.  
Remote Address  
The remote address table allows users to set several remote site IP addresses and ports.  
When sending data, the device will send UDP data to the IP addresses in the table.  
Instruction Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UART  
UART or Universal Asynchronous Receiver Transmitter refers to the ‘RS-232 serial port’  
of the NETRS2321P. All of the port settings are modified from this page.  
Once you have completed making changes, press "Update" to store the data. Reset the  
device to take effect.  
Baud rate  
Set the baud rate of UART interface. The NETRS2321P supports 110, 300, 1200, 2400,  
4800, 9600, 19200, 38400, 57600, 115200 and 230400bps baud rates.  
Character Bits  
Set the number of data length of UART interface. The NETRS2321P supports character  
bits of 5, 6, 7, or 8 bits.  
Parity Type  
Set the parity of UART interface. The NETRS2321P supports parity settings of Odd,  
Even, Space, Mark or none.  
Stop Bit  
Set the stop bit length of UART interface. The NETRS2321P supports 1, 1.5 or 2 stop  
bits.  
Instruction Manual  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Flow Control  
Set the flow control mode of UART interface as enabled or as none.  
UART Memory Overflow count  
Shows the number of overflow bytes in network buffer.  
UART FIFO Overflow count  
Shows the number of overflows counted in the UART RX buffer.  
Delimiter  
This sets the Character 1 and/or Character 2 to be used as the delimiter. When  
sending data from serial to TCP the data is first stored in the cache. When set, not until  
the value of character 1 or 2 is received from the serial side is the data released from  
the cache and sent to TCP.  
Silent time - If there is no data sent or received for the number of milliseconds  
specified the connection is dropped.  
The Drop Character drops the delimiter character of the serial port when sending to  
TCP, (the receiver doesn't display the character).  
Reset Device  
Pressing the “Resetbutton will force the NETRS2321P to do system reset action.  
Instruction Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Virtual COM Software Operation  
The Virtual Com application lets you install and configure your NETRS2321P easily over  
the network. Five function groups are provided to ease the installation process, allow  
COM mapping, and provide monitoring and IP location server functions.  
Configuration  
Once the software is installed and you have searched the device on your network  
(outlined in Installation section), all NETRS2321P devices on the LAN should appear in  
the list of available devices.  
Select the one you would like to adjust and click the Configure button. You will be  
prompted to enter your User ID and Password (Default: admin / admin)  
Configure the device and press the OK button  
Instruction Manual  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COM Mapping  
To map a virtual COM port, select COM Mapping from the left pane of the VCOM  
application, then click Add  
Click OK to create the COM Mapping  
TCP/UDP  
Depending on the protocol you are using, the options below will enable/disable  
automatically as applicable.  
Server/Client (TCP Mode only)  
Set the device to be a Telnet Server. In server mode, the Telnet port listens and waits  
for a host or other client to make a connection. In this case the Ethernet connected  
device is the client.  
Instruction Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set the device to be a Telnet Client. In the case the Ethernet connected device is the  
Telnet server or other NETRS2321P in server mode.  
IP Address  
Depending on your selections above, there are one of three scenarios:  
TCP Server - Disabled  
TCP Client - Remote Server Address  
UDP - Remote Target Address  
Local Port  
Assigns the local port for the device to listen on  
TCP Server – Assigns the TCP server port number that the server will listen on  
TCP Client – Disabled  
UDP – Assign the UDP port that this unit listens on  
COM  
Assign the desired virtual COM port number  
Remote Port  
TCP Server – Disabled  
TCP Client – Assign the remote TCP port you wish to communicate on  
UDP – Assign the remote UDP port you wish to communicate on  
Enable Control Connection (TCP Server or Client Only)  
Enables/Disables control of the serial device on a remote network. Using the IP  
address and port number allows the user to gain control of the receiver from a remote  
location when this is enabled.  
Second(s) for reconnection interval  
Dictates the duration that the software will automatically attempt to reconnect the  
COM port to the serial port on the serial device server, for the purpose of keeping the  
connection alive.  
Instruction Manual  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Applications  
UDP  
TCP  
TCP Server  
Mode  
Instruction Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
1x DB-9 (9-pin; D-Sub) Male  
1x RJ-45 Female  
Connectors  
Serial Protocol  
Maximum Baud Rate  
Data Bits  
RS-232  
230400  
5,6,7,8  
Flow Control  
RTS/CTS, None  
Parity  
Odd, Even, None, Space, Mark  
1, 1.5, 2  
Stop Bits  
Supported Protocols  
Supported Network Link Speeds  
Power Adapter  
DHCP, TCP/IP, UDP, HTTP, ICMP, ARP, Telnet  
10/100 Mbps  
12V, 1A  
Enclosure Material  
Operating Temperature  
Storage Temperature  
Dimensions  
Aluminum  
0°C to 60°C (32°F to 140°F)  
-10°C to 70°C (14°F to 158°F)  
81 x 53 x 23 mm  
295g  
Weight  
Windows® 8 (32/64-bit), 7 (32/64), Vista  
(32/64), XP (32/64), 2000 Windows® Server  
2008 R2, 2003 (32/64)  
Compatible Operating Systems  
Instruction Manual  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Support  
StarTech.com’s lifetime technical support is an integral part of our commitment to  
provide industry-leading solutions. If you ever need help with your product, visit  
www.startech.com/support and access our comprehensive selection of online tools,  
documentation, and downloads.  
For the latest drivers/software, please visit www.startech.com/downloads  
Warranty Information  
This product is backed by a two year warranty.  
In addition, StarTech.com warrants its products against defects in materials  
and workmanship for the periods noted, following the initial date of purchase.  
During this period, the products may be returned for repair, or replacement with  
equivalent products at our discretion. The warranty covers parts and labor costs only.  
StarTech.com does not warrant its products from defects or damages arising from  
misuse, abuse, alteration, or normal wear and tear.  
Limitation of Liability  
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their  
officers, directors, employees or agents) for any damages (whether direct or indirect,  
special, punitive, incidental, consequential, or otherwise), loss of profits, loss of business,  
or any pecuniary loss, arising out of or related to the use of the product exceed the  
actual price paid for the product. Some states do not allow the exclusion or limitation  
of incidental or consequential damages. If such laws apply, the limitations or exclusions  
contained in this statement may not apply to you.  
Instruction Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hard-to-find made easy. At StarTech.com, that isn’t a slogan. It’s a promise.  
StarTech.com is your one-stop source for every connectivity part you need. From  
the latest technology to legacy products — and all the parts that bridge the old and  
new — we can help you find the parts that connect your solutions.  
We make it easy to locate the parts, and we quickly deliver them wherever they need  
to go. Just talk to one of our tech advisors or visit our website. You’ll be connected to  
the products you need in no time.  
to access exclusive resources and time-saving tools.  
StarTech.com is an ISO 9001 Registered manufacturer of connectivity and technology  
parts. StarTech.com was founded in 1985 and has operations in the United States,  
Canada, the United Kingdom and Taiwan servicing a worldwide market.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Speaker System XLHF201P User Manual
Snapper Lawn Mower 1600211 User Manual
Sony Camcorder BRC 300 User Manual
Sony Camera Lens SEL55F18Z User Manual
Sony Ericsson Cell Phone J200c User Manual
Sony Network Card PCWA C500 User Manual
Sony Stereo Receiver STR DE698 User Manual
Sterling Plumbing Indoor Furnishings S1201 0 User Manual
Sterling Plumbing Musical Table scc2 User Manual
Symphonic TV VCR Combo SC313B User Manual