Speco Technologies
IP Camera User’s Manual
IP Camera User’s Manual
(Version 1.3.2)
IP-INTB1 & IP-INTB2 & IP-WDRB1
Network Bullet Cameras
IP-INTD3 & IP-INTD4
Network Dome Cameras
IP-INTT5 & IP-T5
Network Traditional Cameras
IP-SD10X
Speed Dome Camera
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Important Notes
ꢁ
ꢁ
The Network Camera may be damaged by electrical and physical shock
Do not try to disassemble the products. Contact or consult the distributor or
Head Office for after sale service. There may be no Quality Assurance for the
products disassembled arbitrarily.
ꢁ
ꢁ
ꢁ
Do not use these products to be connected with life related device like
medical apparatus.
Do not touch the front lens of the camera. It is one of the most important
parts of the camera.
Never allow the camera face to strong light directly. It can damage the CCD.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Contents
1. FEATURE............................................................................ 8
1.1.
1.2.
PACKAGE ............................................................................................................ 8
DIMENSION AND CAMERA FEATURES................................................................... 9
1.2.1.
1.2.2.
Dimensions .................................................................................................................................. 9
Camera Feature......................................................................................................................... 11
2. INSTALL AND CHECK VIDEO................................................ 14
2.1.
2.2.
INSTALLATION.................................................................................................... 14
VIDEO CHECK ................................................................................................... 14
3. BASIC SETTING ................................................................. 19
3.1.
3.2.
CHECK NETWORK AND INSTALLATION TYPE ...................................................... 19
INSTALLATION WITHOUT IP SHARING DEVICE (ROUTER)..................................... 20
3.2.1.
3.2.2.
Static IP Setup........................................................................................................................... 20
Dynamic IP Setup ..................................................................................................................... 23
3.3.
3.4.
INSTALLATION WITH IP SHARING DEVICE (ROUTER).......................................... 25
CAUTIONS......................................................................................................... 29
4. EXPERT SETTING............................................................... 31
4.1.
GENERAL SETTING............................................................................................ 33
4.1.1.
Title Setting................................................................................................................................ 33
Administrator’s ID and Password Change........................................................................... 34
User Registration ...................................................................................................................... 34
User List and Delete................................................................................................................. 35
Skip Login (Automatic Monitoring)..................................................................................... 35
Time Zone Setting .................................................................................................................... 36
Set Download Route of Plug-in Type ActiveX.................................................................... 36
Select Language....................................................................................................................... 37
4.1.2.
4.1.3.
4.1.4.
4.1.5.
4.1.6.
4.1.7.
4.1.8.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.2.
4.3.
NETWORK SETTING ........................................................................................... 37
VIDEO SETTING................................................................................................. 38
Video Setting ............................................................................................................................. 38
COLOR SETTING ............................................................................................... 39
4.3.1.
4.4.
4.5.
ALARM SETTING................................................................................................ 39
4.5.1.
4.5.2.
Alarm Event Setting.................................................................................................................. 39
Alarm Event Test....................................................................................................................... 41
4.6.
DIO SETTING (SUPPORT FOR IP-INTT5/T5, IP-SD10X).............................. 41
MOTION AREA SETUP........................................................................................ 42
CAMERA SETTING(SUPPORT FOR IP-SD10X).................................................. 43
HOMEPAGE UPDATE.......................................................................................... 44
4.7.
4.8.
4.9.
4.10. FIRMWARE UPDATE........................................................................................... 44
4.10.1. Remote Upgrade....................................................................................................................... 45
4.10.2. System Re-booting.................................................................................................................. 47
4.11. FACTORY RESET ............................................................................................... 48
4.11.1. Reset Button.............................................................................................................................. 48
4.11.2. In reset of Factory default ...................................................................................................... 48
5. BASIC USE........................................................................ 50
5.1.
5.2.
USE OF WEB VIEWER........................................................................................ 50
USE OF OSD (NOT AVAILABLE WITH IP-T5).................................................... 53
5.2.1.
Function...................................................................................................................................... 53
OSD Menu Setting.................................................................................................................... 56
Operating Camera OSD Menu (Intensifier Cameras) ........................................................ 57
Operating WDR Camera OSD Menu (IP-WDRB1).............................................................. 77
Operating Camera OSD Menu (IP-SD10X) ......................................................................... 79
DIP SW SETTING ...................................................................................................................... 97
ID SETTING(1-ON, 0-OFF)(1ꢂ10) ...................................................................................... 97
PROTOCOL ................................................................................................................................ 98
BAUD RATE SETTING.............................................................................................................. 98
5.2.2.
5.2.3.
5.2.4.
5.2.5.
5.2.6.
5.2.7.
5.2.8.
5.2.9.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.3.
5.4.
USE OF IP SETTING UTILITY.............................................................................. 99
USE OF SERVICE SERVER................................................................................ 101
5.4.1.
User Registration .................................................................................................................... 102
Camera Registration............................................................................................................... 104
List of Camera......................................................................................................................... 105
Change of User’s Information.............................................................................................. 107
Search Camera...................................................................................................................... 108
5.4.2.
5.4.3.
5.4.4.
5.4.5.
5.5.
SEE AND CONTROL OF STILL IMAGE IN MOBILE OR PDA................................ 109
5.5.1.
5.5.2.
WAP2.0 (HTML)....................................................................................................................... 109
PDA(WinCE)..............................................................................................................................112
5.6.
USE OF NVR PROGRAM...................................................................................113
5.6.1.
5.6.2.
5.6.3.
Required Specification of PC and OS.................................................................................113
Supported O/S .........................................................................................................................113
Refer the NVR User’s Manual in the CD-ROM..................................................................113
6. NETWORK ENVIRONMENT ..................................................115
7. APPENDIX........................................................................118
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
1. Feature
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
1.
Feature
1.1.
Package
Software CD
IP/Network Camera
Quick Install Guide
Cross LAN Cable
Accessory Pack
Power Lead Cable
Package of Products is composed of main body of product, Software CD (NVR Program, IP Utility,
Product Manual, NVR Manual) , Quick Install Guide, Cross LAN Cable, Accessory Pack, Power Lead
Cable.
Please check before starting installation.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
1.2.
Dimension and Camera Features
1.2.1. Dimensions
1) Bullet Camera
①
②
③
2) Dome Camera
①
②
③
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3) Traditional Camera
②
①
③
3) Speed Dome Camera
①
②
③
1)
2)
3)
Power Port: Power connection port (12 VDC)
VIDEO Port : Video Output Port (BNC)
LAN Port: LAN Connection Port ( Connect with LAN Cable for Local Network or Internet
Viewing)
ꢃ
ꢃ
LINK: LED On (When the product connects with LAN Cable)
DATA: LED On (When user connects the product to the Network)
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
1.2.2. Camera Feature
I.
Intensifier Cameras (Not available with IP-T5)
SLC ( Speco Light Compensation )
1)
:
When the image is in front of strong background lighting, your camera
allows you to get a clear image.
2)
3)
Intensifier: 1/3 inch double density CCD and digital processor permit high quality pictures
to be captured in very low light conditions.
High Resolution: The horizontal resolution of 540TV lines is achieved by using a
SONY CCD having Double Speed 410,000 pixels.
4)
5)
6)
7)
Motion Detection: Video motion detection is built in to the camera.
OSD: Full on screen control of all critical features.
Reduce Noise
:
A DSP chip that removes image noise efficiently in low light conditions.
Electronic Day/Night: Allows the camera to always remain in color or to switch into B/W at
night.
8)
Manual/DC Lens : You can choose MANUAL or DC LENS by using this switch.
II.
Speed Dome Camera
1)
2)
3)
4)
5)
6)
7)
8)
9)
DVD Quality Video Streaming
MPEG4, JPEG Triple stream capability
100X Zoom(10X Optical Zoom with 10X digital zoom)
±0.02° dome system accuracy with 1/4 micro step
360° Endless Rotation
Compensation function: preset position
Over 200°/Sec Preset Speed
Polarity Protection of Power (DC12V)
Filter changeable True Day/Night
10) Various Surveillance Functions
11) Auto Scan / 8 Group Tour / 20 Preset positions / 8 Patterns / 8 Sectors
12) 2 Alarm input
13) 4 Privacy Masking Zones
14) High picture quality 1/4” SuperHAD CCD
15) High sensitivity 0.1 lux / 0.002 lux(Sense-up x128)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
16) Camera OSD control with client program
17) Super Day/Night Function with Power Sensor-up engine
18) Intelligent Pan/Tilt Controlling
19) High-frame rate of up to 30fps at 704x480 size image
20) 4 selectable image sizes – D1,Half D1,2CIF,CIF
21) Simultaneous access up to 20 users
22) Intelligent motion detection and alarm trigger function
23) Pre-alarm recording with ftp server
24) Networking security : Password protection & Encryption
25) Access priority setting capability
26) Analog composite video output for local analog viewing or recording
27) Supports NVR@PC, Viewer@PDA, Mobile Phone
III. WDR Camera
1)
2)
3)
4)
5)
6)
7)
High picture quality 1/3” CMOS
High Resolution of 540TV Line
Superior Wide Dynamic Image Quality
Digital pixel System
Weatherproof Design with IP66
Single body type stand: Protect video and power line
OSD Control
-
-
-
-
-
Auto White balance
Automatic gain control(max.38dB)
Slow shutter, agc on/off
Lens type control
Auto exposure control
8)
9)
Synchronization: Internal/External selectable
Camera ID:User writable camera title
10) MPEG4,JPEG Triple stream capability
11) Intelligent Motion detection and alarm trigger function
12) Pre-alarm recording
13) Networking security: Password protection
14) Analog composite video output for local analog viewing or recording
15) Supports NVR@PC, Viewer@PDA, Mobile Phone
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
2. Install and Check Video
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
2.
Install and Check Video
2.1.
Installation
1)
2)
3)
Connect the IP Camera to the PC by LAN cable (Crossover Cable)
Supply power to the camera using a 12 volt DC regulated power supply.
Wait approximately 2 minutes until the Link/LED light comes on.
2.2.
Video Check
Basic network setting value of the camera is to be:
ꢃ
ꢃ
ꢃ
IP Address: 192.168.1.7
Subnet Mask: 255.255.255.0
Gateway: 192.168.1.1
To connect THE CAMERA into the user’s PC, change the setting value of the PC network
environment.
Fig. 2―1 Network Setting of User PC
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
1)
IP Camera User’s Manual
Set IP Address, Subnet Mask and Gate-way of User’s PC with 192.168.1.50, 255.255.255.0
and 192.168.1.1 as shown on [Fig. 2-1].
Fig. 2―2 Web Browser Input
2)
Run Web Browser as [2-2] and input 192.168.1.7 in URL and click “Enter”, then [2-3] is
shown. In case [2-3] does not appear, re-set Hardware (Reset Button in Camera) to reboot
and run Web Browser, input 192.168.1.7 in URL line and click “Enter” .
Fig. 2―3 THE CAMERA Main Page
Click “Connect” Button of [Fig. 2-3].
3)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
(1)
Fig. 2―4 User login
4)
5)
Input ID and Password on [Fig. 2-4] to see Video.
User’s Authority to see Video on THE CAMERA is as follows ;
Table 2-1 User ID, Password, Rights
User ID
User Password
Guest
Rights
Guest
Monitor only
PTZ (select models only)
PTZ
Monitor,
Control
of
P/T/Z,
Control of Relay
Audio (select models only)
Iaudio (select models only)
PCAudio (select models only)
Audio
Monitor, Hearing
Iaudio
Monitor, Bi-directional Audio
Monitor, P/T/Z, Relay Control,
Hearing (1 way Audio)
All Function
PC Audio
root
root
6)
Above [Table 2-1] is the value set in THE CAMERA. Change the User Information in
‘General Setting’ after installing the camera.
7)
8)
Click (1) after input ID: root, Password :root in [2-4].
Message Window [2-5] appear soon, click ‘Yes’.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 2―5 ActiveX Download
9)
Upon installation, Web Viewer [Fig. 2-6] appears and the image of the Camera can be
seen.
Fig. 2―6 Web Viewer
10)
After checking proper operation as seen on [Pic 2-6], go onto the next Chapter (3) Basic
Setting.
11) Refer to (5) Basic Use’ to see the details of how to use Web Viewer.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3. Basic Setting
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3.
Basic Setting
3.1.
Check Network and Installation Type
This Chapter is for basic setting of THE CAMERA. To install Hardware of the Network Camera,
basic understanding of Networking is required. Please refer to Chapter 6 in case knowledge of
Network Environment is required. There are 2 ways to install Hardware. One is to install THE
CAMERA without IP sharing Device under Cable Modem or Leased Line, the other one is to install
THE CAMERA under an IP sharing Device , which is required necessarily under PPPoE environment,
and even under Leased Line or Cable Modem. The default IP Address of THE CAMERA is preset to
192.168.1.7 and Subnet Mask to 255.255.255.0 and Gateway to 192.168.1.1 in the factory. This
explanation is based upon default value of the factory.
Caution 1 : Check Video before installation, on ‘2. Install and Video Check’.
Caution 2 : In case using IP sharing Device, only Global IP is available.
Caution 3 : THE CAMERA does not support PPPoE. IP Sharing Device is required to connect to
THE CAMERA under PPPoE.
Installation without IP sharing device
-> For static IP, refer to ‘Static IP Setup’.
-> For dynamic IP, refer to ’ Dynamic IP Setup’.
Installation with IP sharing device
-> Should set up with Static IP. Refer to ‘Installation with IP Sharing Device’.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3.2.
Installation without IP sharing device (Router)
3.2.1. Static IP Setup
1)
2)
3)
After checking Video in ‘Video Check’, go to the next step.
Connect THE CAMERA to PC with LAN Cable (Crossover Cable).
Cable connection and Network Setup should be same as shown in ‘2. Install and
Video Check’.
4)
Run Web Browser and input 192.168.1.7 in URL and click ‘Enter’, then [Fig. 3-1] will
appear.
Fig. 3―1 Main Page of THE CAMERA Network Camera
5)
Click ‘Administrator’s Page’ of [Fig. 3-1], then Browser shows [3-2] Log-in
Page.
Fig. 3―2 Administrator Page Log-in
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
6)
Put ‘admin’ in ID and Password line, click ‘Login’, then [3-3] ‘Administrator's Page’
will be shown. (ID, Password of THE CAMERA is preset as admin/admin in
Administrator’s Page. Change Administrator’s ID and Password in General Setting of ‘4.
Expert Setting’
Fig. 3―3 Administrator’s Page
7)
8)
Click “Network Setting’ in left menu on [3-3], [3-4] appears.
Click ‘Static IP Address’ in ‘IP Setting’ of [3-4], and input IP Address, Subnet Mask,
Default Gateway according to Network environment to connected THE CAMERA to.
For setting of ‘DNS Server’, input DNS Address to fit with Network Environment to set.
Use DNS value normally set in PC.
9)
10)
11)
DNS Address must be entered.
Click ‘Save’ Button of [3-4] to save setting value.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 3―4 Network Setting
12)
13)
Click ‘Click Here’ upon appearing of IP Change Window of [3-5].
IP Change loading Page appears as [3-6], the Main Page of changed address is
connected. (Note: You may not find the main page of changed address under
Cross Cable connection, but IP has been changed.)
Pic 3―5 IP Change
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 3―6 IP Change loading Page
14)
15)
16)
17)
Remove LAN Cable (Cross Cable) connected between THE CAMERA and PC.
Connect THE CAMERA to Network with LAN Cable (Straight Cable).
Connect PC to Network with LAN Cable (Straight Cable)..
Set up IP Address, Subnet Mask and Gateway of PC according to the Network
environment.
18)
Check
ꢃ
Run Web Browser on PC, input IP address set in THE CAMERA onto URL
and click ‘Enter’,
ꢃ
ꢃ
ꢃ
Check if IP Setting is correct or not, referring to ‘Video Check’
If Video is seen, THE CAMERA has been correctly set up.
If Video is not seen, check whether there may be a conflict of IP in the
Network, and re-check the set value of Network environment of THE
CAMERA, and Network environment of User’s PC.
3.2.2. Dynamic IP Setup
ꢃ
Do not set up Dynamic IP in the camera except as a direct
connection of Cable Modem supporting Dynamic IP with the
camera.
ꢃ
Reset, in case IP has not been allocated to THE CAMERA in
Dynamic IP Setting, to go to Initial Value and try again.
1)
2)
3)
After checking Video in ‘Video Check’, then go to the next step.
Connect THE CAMERA and LAN Cable (Cross Cable)
Cable Connection and Network Setting should be done same as per ‘2. Install and
Video Check’.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4)
Go to Network Setting Page of Administrator’s Page as per 4), 5), 6), 7) of ‘Static
IP Setup’.
Fig. 3―7 Network Setting
5)
6)
7)
Click on ‘Dynamic IP Address’ in ‘IP Setting’.
Click ‘Save’ Button.
Upon completion of setting, close the Web Page and find IP of THE CAMERA in ‘IP
Utility’
program provided with Proprietary Viewer (see ‘5. Basic Use’)
If the IP is found, THE CAMERA has been given an IP. But in case the IP is not found,
do a re-set of [2-1] to go to initial value because it has not been given an IP,
then re-start the IP Setting. Once THE CAMERA has an IP, remove the LAN Cable
(Crossover Cable) connected between THE CAMERA and the PC.
Connect THE CAMERA to the Network with LAN Cable (Straight Cable).
8)
9)
10) Connect PC to Network with LAN Cable (Straight Cable).
11) Set IP address of PC, Subnet Mask and Gateway properly according to the Network
Environment.
12) Check
After registration of THE CAMERA in Service Server (refer to ‘Use of Service Server’ of ‘ 5.
Basic Use’,
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
connect to THE CAMERA by Domain Name (Server Name) allocated to THE CAMERA.
For example, run Web Browser and input Domain Name allocated to THE CAMERA in URL.
In http://IPXXXXX.ipcam4u.net, ‘IPXXXXX’ is to be Name of Server registered in Service
Server by user.
If the initial page is shown as [3-8], check Video of THE CAMERA referring to ‘2. Install
and Video Check’. If Video is seen, set up is properly done.
Fig. 3―8 Initial Page of THE CAMERA
3.3.
Installation with IP Sharing Device (Router)
1)
2)
3)
After checking Video in ‘2. Install and Video Check’, then go to the next step.
Connect THE CAMERA and PC with LAN Cable (Crossover Cable).
Cable Connection and Network Setting should be done same as per ‘2. Install and
Video Check’.
4)
5)
6)
Go to Network Setting Page of Administrator’s Page as per 4), 5), 6), 7) of ‘Static IP
Setup’.
Click ‘Static IP Address’ in ‘IP Setting’ of [3-9], and input IP Address, Subnet Mask,
Default Gateway according to Network environment to connected THE CAMERA to.
For setting of ‘DNS Server’, input DNS Address to fit with Network Environment to set.
Use DNS value normally set in PC.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
7)
IP Camera User’s Manual
DNS Address should be input. In case THE CAMERA is installed under IP Sharing
Device, input local IP of Router in 2nd DNS Server Address.
8) Click ‘Save’ Button of [3-9] to save the set value.
Fig. 3―9 Network Setting
9)
Click ‘Click Here’ upon appearing of IP Change Window of [3-10].
10) IP Change loading Page appears as [3-11], the Main Page of changed address is
connected. (may not find the main page of changed address under Crossover Cable
connection, but IP has been changed.)
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 3―10 IP Change
11) It is connected to the new IP set up, in 20 seconds after window of [3-11] appears.
12) Check Video of THE CAMERA referring to ‘2. Install and Video Check’ as soon as it
is connected to the new IP.
13) Go to Network Setting Page of Administrator’s Page as per 4), 5), 6), 7) of ‘Static
IP Setup’.
Fig. 3―11 IP Change loading Page
Fig. 3―12 Port Setting
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
14) Set Port in Port Setting Page of [3-12]. It is required to set each different Port for
many THE CAMERA Network Cameras under 1 Router.
15) Click ‘Save’ Button to save set value.
16) Remove LAN Cable (Crossover Cable) connected between THE CAMERA and PC.
17) Connect THE CAMERA to Network with LAN Cable (Straight Cable).
18) Connect PC to Network with LAN Cable (Straight Cable).
19) Port-Forward the port designated to use THE CAMERA, in IP Sharing Device. Refer
to manual of IP Sharing Device for details.
20) Check 1 (local check)
Run Web Browser and input IP address of THE CAMERA in URL and click ‘Enter’. If you
changed Web Server Port, you must input ‘http://IP Address:Port Number’. For example, if
you set IP address of THE CAMERA to 192.168.10.88 and changed Web Server port to 81,
you must input http://192.168.10.88:81.
Fig. 3―13 Main Page of THE CAMERA
After [3-13] appears, check Video of THE CAMERA referring to‘2. Install and Video Check’.
21)
Check 2 (Check from outside)
After registration of THE CAMERA in Service Server (refer to ‘‘Use of Service Server’ of ‘‘ 5.
Basic Use’,
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
connect to THE CAMERA by Domain Name (Server Name) allocated to THE CAMERA.
For example, run Web Browser and input Domain Name allocated to THE CAMERA in URL.
In http://IPINTB1.ipcam4u.net , ‘IPINTB1’ is to be Name of Server registered in Service
Server by user.
If the initial page is shown, check Video of THE CAMERA referring to
Video Check’. If Video is seen, set up is properly done.
‘2. Install and
3.4.
Cautions
If the firewall is used for security purpose, THE CAMERA may not work properly. In this case, open
the port of THE CAMERA, then it will work properly. The port being used by THE CAMERA can be
checked
on ‘Port Setting’ of ‘Network Setting’ of ‘Administrator’s Page’.
Port of THE CAMERA on ex-factory is set default as follows ;
ꢀ
ꢀ
ꢀ
ꢀ
Web Connection Port: Port 80 TCP
Authentication and Control Port: Port 9000 TCP
Video Streaming Port: Port 9001 TCP
Motion Detection Control Port : Port 9005 TCP
In setting user port, do not use 1504, 1508, which port is used in THE CAMERA itself.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4. Expert Setting
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.
Expert Setting
After registration of THE CAMERA in Service Server (refer to ‘Use of Service Server’ of ‘‘ 5.
Basic Use’’, connect to THE CAMERA by Domain Name (Server Name) allocated to THE
CAMERA. (For example, run Web Browser and input Domain Name allocated to THE
CAMERA in URL. In http://ipcam4u.net, ‘THE CAMERA’ is to be Name of Server registered
in Service Server by user)
Click ‘Administrator’s Page’ on Initial Page of THE CAMERA, login Page of [4-1] appears.
Put ‘admin’ in ID and Password line, click ‘Login’, then [4-2] ‘Administrator's Page’ will be
shown. (ID, Password of THE CAMERA is preset as admin/admin in Administrator’s Page.
Change Administrator’s ID and Password in General Setting of ‘4. Expert Setting’. )
Fig. 4―1 Administrator’s Page Login
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 4―2 Administrator’s Page
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.1.
General Setting
Fig. 4―3 General Setting
4.1.1. Title Setting
Fig. 4―4 Title Setting
Server title is to be English without space.
Click ‘Save’ Button to save title after input name.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.1.2. Administrator’s ID and Password Change
※ Cautions : Change Administrator’s ID and Password and do not disclose the information to
others.
Administrator’s ID and Password should be English, within 20 characters, without space.
Click ‘Save’ Button to save the changed value after change Administrator’s ID and Password.
Fig. 4―5 Administrator’s ID and Password Change
Remember Administrator’s ID and Password. In case of forgetting Administrator’s ID and
Password click the camera’s ‘reset’ button to return to the initial value, and change
Administrator’s ID and Password.
4.1.3. User Registration
This is to register an account of a user who can monitor and control Video of THE CAMERA.
Administrator’s ID and Password should be English, within 20 characters, without space. Assign
the authority to users and click ‘Save’ button. Maximum number of users to be registered is 100
people.
ꢀ
ꢀ
View Only: Monitoring only.
PTZ + Control: Monitoring, Control of P/T/Z of Camera and Relay. (select models
only)
ꢀ
ꢀ
Audio: Monitoring, and hearing Audio of Server. (select models only)
Interactive Audio: Monitoring, Two-way Audio Communication with Camera Server
(select models only)
ꢀ
ꢀ
PTZ + Control + Audio: Monitoring, Control of P/T/Z of Camera and Relay, Hearing
Audio of Camera Server. (select models only)
All : Monitoring, Control of Camera P/T/Z and Relay, two-way Audio Communication
with Camera Server, (Preset available)
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 4―6 User Registration
4.1.4. User List and Delete
Fig. 4―7 User List
User list is available on clicking ‘List Users’ on [4-7], to check list and delete user ID in [4-8].
User ID ‘guest’, ‘PTZ’, ‘audio’, ‘Iaudio’, ‘PC Audio’, ‘root’ has be pre-registered as basic user
ID on ex-factory.
Fig. 4―8 User List
4.1.5. Skip Login (Automatic Monitoring)
Fig. 4―9 Skip Login
Tick on ‘Skip Login’ of [4-9], and click ‘Connect ID’ and save the value, then Web Viewer will
appear automatically and Video of Camera can be seen upon connection to Home Page of THE
CAMERA.
Save ‘Connect ID’ according to user authority. If you don’t tick on ‘Skip Login’, it is available to
connect to THE CAMERA Home Page but you can see Video of Camera. In this case, input user
ID and Password for connection to see Video of Camera.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.1.6. Time Zone Setting
This is to set Time zone of location where THE CAMERA is to be installed, to set up local time
in case of monitoring from different time zone area. Select one of time zone in ‘Set Time Zone’
and save.
Fig. 4―10 Time Zone
Click ‘Display’ in [4-10] to see current time set in THE CAMERA.
Fig. 4―11 Current Time View
In case THE CAMERA does not keep correct time, click ‘Update’ Button to get new time
information from set time zone.
4.1.7. Set Download Route of Plug-in Type ActiveX
This is to set how to download ActiveX of Web Viewer, locally or from outer Server designated.
In case setting as local download, it has a merit to use in private network without Internet. In
case of setting as download from outside, it has a merit to download the updated Active X of
Web Viewer automatically.
Fig. 4―12 Plug-in Download Route
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.1.8. Select Language
This is to select language to be displayed in all Web Pages such as Administrator’s Page, Web
Viewer and Main Page of THE CAMERA.
Fig. 4―13 Select Language
It supports both English and Japanese. Click ‘Save’ Button to save the set value after select the
Language. Input ID and Password to connect Administrator’s Page, and go to ‘Home Page
Update’->’Default Home Page Setting’->’Default’, and change the main Page and Login Page of
THE CAMERA to the selected language.
4.2.
Network Setting
This is to set Network to use THE CAMERA. Set Network to fit user’s network environment in
‘3. Basic Setting ’. Change Network information to fit environment for THE CAMERA to be installed
in.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.3.
Video Setting
Fig. 4―14 Video Setting
4.3.1. Video Setting
Select and tick on the Channel to use, input Video format (NTSC or PAL), Compressed resolution,
Bit rate, Frame rate, Key frame. Video setting can be done automatically by pressing ‘High’,
‘Normal’, ‘Low’ according to the Network Speed at which THE CAMERA is installed.
Fig. 4―15 Video Setting
To return to default of ex-factory, click ‘Default’ of ‘Video Default Setting’
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.4.
Color Setting
This is to adjust color of channel.
Fig. 4―17 Display Color Setting
Upon adjustment of color on [4-17], then click ‘Save’ to save the setting value. In case to
return to default, click ‘Default’ to go to default. Even in this case, it is required to click ‘Save’
Button to save the setting value.
4.5.
Alarm Setting
4.5.1. Alarm Event Setting
To get Alarm Service on THE CAMERA, go to ‘Administrator's Page’ꢄ’Alarm Setting’ and tick
‘Enable’ in ‘Alarm’.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 4―18 Alarm Setting
Designate condition to drive Event in ‘Alarm Condition’, such as Sensor Event, Motion detection
Event or Sensor + Motion detection Event, If Sensor Event is selected, make Sensor settings
Upon event situation after setting on ’Enable’ in ‘Alarm’ of ‘Alarm Event’, Event is to be transmitted
to user’s Viewer and inform detection of Event, with flickering on screen and alarm sound. (refer to
5. Basic Use).
To use SMS Service and E-mail transmitting Event to Alarm Server, go to ‘Alarm Style’-> ‘Alarm
Server’ and input Domain Name of Alarm Server (‘Alarm Server’ is defaulted as Ipcam4u.net).
To send the recorded video to FTP Server upon alarm event, go to ‘Alarm Style’-> ‘FTP’ and
input FTP Server Address, Directory, User IP and Password, FTP Directory (mandatory). Make the
user’s directory in ftp root of User’s FTP Server to get recorded files to be transmitted. Click ‘Save’
Button to save setting.
In case of setting to send Event to Alarm Server, register THE CAMERA in Service Server to use
Alarm Server (refer to ‘‘Use of Service Server’ in ‘ 5. Basic Use)
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.5.2. Alarm Event Test
Click ‘Test’ of [4-18], THE CAMERA will work as if Alarm has happened. In case selected ‘Alarm
Style ->’Alarm Server’, Event is to be notified to Alarm Server and is to recorded into the
recorded file (10 seconds before and 50 seconds after Event), and to be sent to Alarm Server.
In case selected to use user FTP Server, the recorded file (10 seconds before and 50 seconds
after Event) is to be saved in FTP Server. It may take some time for Alarm Message to get to
user’s Mobile Phone or by E-mail, in some cases. If THE CAMERA has been registered in Service
Server, it is available to check the details of Event and also change the Alarm Message of E-mail
and Mobile Phone to be sent upon Event, in Alarm Server Homepage (Ipcam4u.net). Refer to
‘Use of Service Server’ in ‘ 5. Basic Use’ for details.
4.6.
DIO Setting (support for IP-INTT5/T5, IP-SD10X)
Fig. 4―19 DIO Setting
Tick on sensor to use and select type of sensor to use.
ꢃ
Sensor Type : designate type of sensor, NC, NO.
Designate name of sensor to use.
4 conditions are selectable for Relay. Relay name is to be input.
ꢃ
Disable: Relay is not active
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
ꢃ
ꢃ
Remote Control: to control Relay through Internet using Viewer
Local Control: Relay is on during ‘Duration’ time upon Event on Sensor, then is
off.
ꢃ
Remote & Local Control: Control Relay through Internet using Viewer. To be ON
during ‘Duration’ time upon event on Sensor, then to be OFF.
4.7.
Motion Area Setup
ꢃ
(1) Motion Area Set: Press the set button. Place the mouse curser on this area and
drag it out to the desired area.
ꢃ
ꢃ
(2) Area Clear: Cancel the former area established.
(3) Save: Please wait for 3 to 5 sec. while camera save the present setting information
by itself.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.8.
Camera Setting(support for IP-SD10X)
Fig. 4-20 Camera Setting
It is available to pre-set Pan/Tilt/Zoom Cameras.
Preset Setting is available up to 20, but may be less than 20 for some model of Camera.
ꢃ
ꢃ
ꢃ
(1) OSD Menu: to activate OSD Menu.
(2) Preset No: to select the Preset Number to set up.
(3) Preset SET: ‘SET’ button is to set the current coordinate as preset location with
name recorded by user. In 3 seconds after pushing ‘SET’ button, the Preset
coordinate is to be set. Don’t move Camera during the time (about 3 seconds).
(4) Preset Move: to move to the selected preset number.
(5) Tour No: to select the Tour Number to set up.
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
(6) Tour Move: to move to the selected preset number.
(7) Pattern No: to select the Pattern Number to set up.
(8) Pattern Move: to move to the selected Pattern number.
(9): Adjustment of Pan/Tilt/Zoom/Speed/Focus: to move to the location to preset by
adjusting Pan/Tilt/Zoom/Focus.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.9.
Homepage Update
Fig. 4―21 Homepage Update
Homepage Update function is for user to upload the main page of THE CAMERA onto user’s
Homepage.
User’s Homepage is composed of 3 files, index.html, top.htm, main.htm. The file for user to use is
main.htm. After making Web Page (main.htm) and save it as file name of main.htm, upload by the
function of ‘Homepage Update’, then main.htm page is to be the 1st main page of THE CAMERA.
(Image file is not uploaded in THE CAMERA.) User Homepage can’t exceed 300Kbyte.
If user wants to re-make user’s homepage into Homepage provided complimentarily, click ‘Default
HomePage Upload’.
4.10. Firmware Update
In case firmware is upgraded in the future, Upgrade Server (http://ipcam4u.net) will
automatically upgrade Firmware of THE CAMERA. Upgrade is only supported through Network.
Information on latest version of THE CAMERA will be posted in Data Room of Speco
Technologies Homepage. (http://www.specotech.com)
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.10.1. Remote Upgrade
Fig. 4―22 Firmware Update
Address of ‘Update Server Address’ in [4-22] is set as ‘ipcam4u.net’.
Check ‘Current Software Version’ in ‘Current Version’ of [4-22] and go ahead with update if
current version is lower than latest version. Upon clicking ‘Update’ button in [4-22] ‘Remote
Update’, [4-23] will appear.
Fig. 4―23 Firmware Update
THE CAMERA will be automatically upgraded upon clicking ‘Download’ button of [4-23]
after connecting to Upgrade Server and checking version.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 4―24 Firmware Download
‘Downloading’ message will be shown until completion of Update as [4-24] (it may take time
according to Network situation). Upon completion of upgrade, there appears message showing
upgrade result.
[4-25] is the message showing that upgrade has been correctly done. Click ‘Restart’ in
‘System Restart’ to restart System of THE CAMERA.
Fig. 4―25 Completion of Upgrade
If [4-26] is displayed as below, this means that THE CAMERA has been upgraded to the
latest Version, there is no need to update any more.
Fig. 4―26 Check of Upgrade Version
If user found [4-27], there is a error in connection to Upgrade Server, re-check Internet
Connection or re-check DNS Server Address in ‘3. Basic Setting’ and try to upgrade again. If
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
user keep finding [4-27] or can’t upgrade, contact head office of Speco Technologies
Fig. 4―27 Upgrade Server Connection Error
4.10.2. System Re-booting
This is the function to re-boot Inner Software of THE CAMERA. Click ‘Restart’ on [4-41]
‘System
Restart’ to reboot all inner program of THE CAMERA.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
4.11. Factory Reset
4.11.1. Reset Button
Press reset button for 1sec to be operated.(Red Circle)
Bullet Camera
Traditional Camera
Dome Camera
Fig. 4―28 Factory reset button
4.11.2. In reset of Factory default
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
Changed to [192.168.1.7] of IP Address.
Changed to [192.168.1.1] of Gateway.
Changed the Server Login Port No. to “Default”.
Changed Web Admin Password to initial data.
Initialized DNS Number.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5. Basic Use
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.
Basic Use
5.1.
Use of Web Viewer
Fig. 5―1 Web Viewer
Table. 5-1 Definition of Web Viewer Button Function
Display Screen reduced by 50%.
Display Screen at 100%. Double-clicking mouse on enlarged
screen
has the same function.
Enlarge Video of a channel to 640 x 480. Double-clicking in a
selected channel has the same function.
Enlarge Video of a channel to full screen
Capture a selected channel into a BMP file
Select Relay to control. Relay name is taken from the Camera
Server
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Relay ON
Relay OFF
Select Preset to control
Select Tour to control
Select Pattern to control
Move to the selected Preset/Tour/Pattern.
Preset Tour. Move to preset location in regular sequence from No. 1
up to 200. Move to next one after 5 seconds pause on a preset
location.
Display Camera Menu functions of Intensifier Cameras
While pressing the mouse in the direction, P/T, Camera moves. Un-
pressing mouse makes Camera stop. Keep pressing on screen to a
point makes the Camera move to the direction, un-pressing mouse
makes Camera stop.
Control Speed of Pan/Tilt. ‘S’ makes speed of P/T slow. ‘F’
makes speed of P/T fast. (for speed dome Cameras)
Zoom In.
Zoom Out.
Focus Near
Focus Far
Flickering on Screen Upon detection of a motion event, the border around the associated
and Alarm Sound
camera picture will flash and an alarm will beep. To stop the sound,
double-click on the flashing screen.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Table 5-2 Definition of Web Viewer Key Board
③
⑥
⑥
①
③
⑤
④
②
ꢃ
‘space ’Key’
②
③
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
ꢃ
Enlarge / reduce Screen
Number Key’
Preset Move Function,
The Number represents the Preset Number
20 Preset is controlled by Key Board
Key Board 1 ~ 0 : Preset 1 ~ Preset 10
Key Board q ~ p : Preset 11 ~ Preset 20
‘Direction Key’
④
⑤
Pan/Tilt of Camera
Pressing on the direction Key makes Camera move to the direction.
Un-pressing stops moving.
ꢃ
Same function as
ꢃ
ꢃ
Zoom-in, Zoom-out Function
⑥
‘+’ is Zoom In, Pressing the key makes doing the function. Un-pressing
stops the function
ꢃ
‘-‘ is Zoom Out, Pressing the key makes doing the function. Un-
pressing stops the function.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.2.
Use of OSD (Not available with IP-T5)
The OSD menu of this camera can be controlled by Web Viewer.
Please refer to the ‘1.2.2 Camera Feature’ for OSD function.
5.2.1. Function
11) Intensifier Cameras (Not available with IP-T5)
SETUP MENU
LENS option
●DC
●MANUAL
SHUTTER
●OFF
●F/L
●MANUAL
WHITE BALANCE
●ATW
●AWC MANUAL●
SLC
●OFF
●LOW ●MIDDLE ●HIGH
AUTO GAIN
●OFF ●ON
REDUCE NOISE
●OFF ●LOW ●MIDDLE ●HIGH
INTENSIFIER
●AUTO
●OFF
NEXT PAGE
●CAMERA TITLE ●COLOR ●SYNC
●PRIVACY ●MIRROR
●DETAIL ●DEFAULT ●PAGE1
EXIT
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
2) Speed Dome Camera (IP-SD10X)
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3) WDR Camera (IP-WDRB1)
SPECO MAIN MENU
PRESETS
SET UP ID
DEFAULT / INDOOR / OUTDOOR / CUSTOM
DISPLAY ID : (OFF / ON)
CAMERA ID : 8 CHARACTER
ID POSITION : (UP-LEFT / UP-CENTER / UP-RIGHT
DOWN-LEFT / DOWN-RIGHT)
LENS SELECT
DC
MANUAL
WDR
AUTO
OFF
MANUAL : (WDR BIAS Range -20 to 20 / WDR RANGE 0 to 36)
WB CONTROL
ATW(Range 2K~11K)
AWB
MANUAL (Range 2K ~11K)
LOW LIGHT
SPECIAL
SLOW SHUTTER : (SHUTTER LIMIT Range OFF~X32 / AGC CONTROL Range 0 to 60)
AUTO D/N
VIDEO : (NTSC / PAL)
FLIP : (OFF / ON)
SYNC : (L,LOCK / INT / INT2)
BACK LIGHT : (OFF / ON : BACK LIGHT ZONES)
RESOLUTION : (NORMAL / HIGH / C_NORMAL / C_HIGH)
COLOR MODE : (COLOR / B/W)
SHARPNESS : ON (Range -8 to 8) / OFF
EXIT MENU
EXIT NO CHANGE
SAVE NEW AND EXIT
RESTORE FACTORY SETTING
RELEASE VERSION
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.2.2. OSD Menu Setting
When you control the OSD by using the joystick on the camera, refer to the following (select
models only)
UP
R
L
E
F
T
I
G
H
T
DOWN
SETUP
When you control by the five keys on the Webviewer GUI refer to the following
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.2.3. Operating Camera OSD Menu (Intensifier Cameras)
1. Press the SET button to access the SETUP mode.
SET UP menu is displayed on the monitor screen.
2. Select the desired feature using the UP or DOWN button.
Each time you press the UP or DOWN button, the arrow
indicator moves up or down.
Move the arrow indicator to the desired feature item.
3. Change the status of the selected feature using the LEFT or
RIGHT button.
If you press RIGHT or LEFT button, it appears available status.
Press the button when gets desired feature.
4. When completed, move the arrow indicator to ‘EXIT" and press
the SET button.
Notes
You can access submenu using SET button.
For the mode with ’---‘, you may not access submenu.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
1) Setting up the LENS
Select the lens pressing the RIGHT button.
① On the SETUP menu screen, move the arrow indicator to the lens
using the UP or DOWN button.
② Select the desired feature using the LEFT or RIGHT button.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
▶When DC LENS selected, press SET button to control the
BRIGHTNESS.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
1) Shutter status and speed control
You can control brightness of the screen by the shutter speed.
① Press the SET button to display the setup menu and move the arrow
indicator to ‘SHUTTER’ using the UP or DOWN button.
② Set ‘SHUTTER’ to the desired mode using the LEFT or RIGHT button.
▶ OFF : Deactivation
▶ FLK(1/100) : Flicker mode
(When WDR is on, the image can flicker a little.)
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
▶MANUAL : When setting shutter speed manually.
(Only for LENS mode)
You can select speed from ‘1/60’ to ‘1/200,000’sec
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
▶ESC : You can control the BRIGHTNESS.
③When completed, press ‘SET’
62
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3) SLC (Speco Light Compensation) - BACKLIGHT
A built-in SR chip provides intelligent light level control to overcome
severe Backlight conditions.
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘BACKLIGHT’ using the UP or DOWN button.
② SET ‘BACKLIGHT’ to the desired mode using the LEFT or RIGHT button.
▶OFF
▶LOW
▶MIDDLE
▶HIGH
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
3) AUTO GAIN CONTROL (AGC)
AGC is to get bright picture. Higher GAIN level, getting brighter screen.
But you can get noise increase.
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘AGC’ using the UP or DOWN button.
② SET ‘BACKLIGHT’ to the desired mode using the LEFT or RIGHT button.
▶OFF
▶ON
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5) WHITE BALANCE (WHITE BAL.)
For color control on the screen, use ‘WHITE BALANCE’ function.
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘WHITE BALANCE’ using the UP or DOWN button.
② Set ‘WHITE BAL.’ to the desired mode using LEFT or RIGHT button.
▶ ATW (Auto Tracking White Balance)
: When color temperature is 2400~12000K, select this
mode.
(ex. A fluorescent lamp, outdoor)
▶ AWC (Auto White Balance Control)
: The white balance is automatically adjusted in a specific environment.
In order to obtain the best result, press the set button while the camera
focuses on white paper. If the environment including the light source is
changed, you have to adjust the white balance again.
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
▶MANUAL : To fine adjust, select the Manual mode. You can increase
or decrease the red or blue factor while monitoring the difference on the
screen. Set to ‘MANUAL’ mode and press the SET button. Increase or
decrease the value for RED(R-Gain) and BLUE(B-Gain), watching the color
of the picture, and press the SET button when you obtain the best color.
Notes
Proper White Balance may not be obtained under the following conditions
in these cases select the AWC mode.
When the scene contains mostly high color temperature object, such as
a blue sky or sunset.
When the scene is dim.
If your camera faces fluorescent lamp directly or is installed in the place
of the changing illumination.
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
6) Digital Noise Reduction (Dynamic Noise Reduction)
DNR is to reduce the noise on the screen.
① Press the SET button to display the SETUP menu and move the
arrow indicator to ‘DNR’ using the UP or DOWN button.
② SET ‘DNR’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶LOW : Low reduction of the noise
▶MIDDLE : Middle reduction of the noise
▶HIGH : High reduction of the noise
Notes
If you change the ‘GAIN’ menu from AGC-L to AGC-H
sensitivity is increased as well as noise on the screen.
When selected ‘GAIN’ menu OFF, DNR will not work.
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
7) INTENSIFIER
IP Camera User’s Manual
Allows you to get clear images with this function under night
or low light conditions
① Press the SET button to display the SETUP menu and move the
arrow indicator to ‘Intensifier’ using the UP or DOWN button.
② SET ‘Intensifier’ to the desired mode using the LEFT or RIGHT button.
▶AUTO : When your camera is under night or low-lighting level,
select this mode.
Notes
If you press SETUP button at ‘AUTO’ menu, you can control the
lowlight action maximum magnifications.(X2~X128)
Increasing the amount of Intensification results in brighter pictures
Under low light conditions, and may increase image lag.
Increasing the amount of intensification may cause image noise
which is to be expected as a normal condition.
68
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
8) NEXT PAGE
IP Camera User’s Manual
① Press the SET button to display the SETUP menu and move the
arrow indicator to ‘Intensifier’ using the UP or DOWN button.
② SET ‘Intensifier’ to the desired mode using the LEFT or RIGHT button.
(A) CAMERA TITLE
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘CAMERA TITLE’ using the UP or DOWN button.
② SET ‘ON’ using the LEFT or RIGHT button.
Notes
If the CAMERA ID feature is set to ‘OFF’, the name will not displayed
in the monitor.
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
③ Press SET button to access the SETUP mode.
④ You can enter up to 15 characters.
a. Move the cursor to character-enter location by using the LEFT
or RIGHT button.
b. Select the desired character by using the UP or DOWN button.
c. Press SET button to confirm the blinking character. The first
character is saved and the cursor in the bottom of the screen
moves to the next position.
d. Repeat steps a, b and c until you create the full name you want.
e. Select the position at which the CAMERA TITLE will b located on
the screen.
Notes
If the CAMERA TITLE feature is set to ‘OFF’, the name will not displayed
in the monitor.
After erasing the character from right to left, correct the character again.
70
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
B) COLOR
IP Camera User’s Manual
You can choose color and B/W mode electronically. (OPTION)
▶ ON : color mode
▶ OFF : B/W mode
▶ AUTO : generally color mode, B/W mode in low luminance.
Notes
OSD Key may not work for 3 seconds when the COLOR/ BW mode is
changed.
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
C) SYNC
IP Camera User’s Manual
Two SYNCHRONIZATION modes are available… INTERNAL and EXTERNAL
LINE-LOCK. In LINE-LOCK mode, the camera syncs to the 60 Hz phase.
① Press the SET button to display the setup menu and move the arrow indicator
to ‘SYNC’ using the UP and DOWN button.
② SET to the desired mode using the LEFT or RIGHT button.
▶ INT : Internal synchronization
▶ L/L : If you choose ‘L/L’, you can adjust the desired phase.
- Press the SET button.
- You can adjust the desired phase from 0 to 270.
Notes
Line Lock is only available in the 24 volt AC mode of operation.
In 12 volts DC, the SYNC menu is always in the ‘INTERNAL’ mode.
72
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
D) PRIVACY
To mask an area that you want to be private.
① Press the SET button to display the setup menu and move the arrow
indicator to ‘PRIVACY’ using the UP and DOWN button.
② SET ‘PRIVACY’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶ON : PRIVACY mode activated
-Press the SET button.
-Move the arrow indicator to area you want to
mask.
-Set ‘ON’ using LEFT or RIGHT button.
-Press the SET button and then set the area’s
bounds
with the method like MOTION DET. set
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
E) REVERSE
IP Camera User’s Manual
① Press the SET button to display the setup menu and move the arrow
indicator to ‘REVERSE’ using the UP and DOWN button.
② SET ‘REVERSE’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶ON : Make a reverse turn to RIGHT or LEFT.
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
F) DETAIL
IP Camera User’s Manual
① Press the SET button to display the setup menu and move the arrow
indicator to ‘DETAIL’ using the UP and DOWN button.
② SET ‘DETAIL’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶ON : DETAIL control mode (level 0~31)
When the level is up, the sharpness will increase.
Control this level to get your best picture quality.
If the level is too high, you can get an unnatural image
with video noise.
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
G) DEFAULT
: Use to reset your camera to FACTORY DEFAULT SETTING.
H) PAGE1
: PAGE 1 : Save the setting of NEXT PAGE function, and then
76
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.2.4. Operating WDR Camera OSD Menu (IP-WDRB1)
OSD MENU CONTROL
CENTER KEY - Used to access menu mode.
Also used to confirm the setting
UP / DOWN KEY - Used to choose the desired menu selection.
LEFT / RIGHT KEY - Used to choose the desired menu feature adjustment.
OSD MENU ENTER / EXIT
A. OSD MENU ENTER
• Push Center Key for 2 seconds
B. OSD MENU EXIT
• Press EXIT Menu from Main Menu
• If Pressing Set Key for 2 seconds from Main Menu appears.
In this case, just press Set Key.
C. 'SAVE' and 'QUIT‘
• Left or Right Key - Selecting Menu
• Up or Down Key - Returning to Menu
1. Press the SET key to access the main setup mode.
2. Select the desired feature using the UP or Down key.
3. Change the status of the selected feature using the LEFT or RIGHT key.
MAIN MENU
A. PRESETS
• DEFAULT : Optimized for normal scenes
• INDOOR : Optimized for indoor scenes with windows and/or glass door to capture details both indoors
and outdoors.
• OUTDOOR : Optimized for sunny outdoor scene to capture detail both in bright areas and shadows.
• CUSTOM : Change the value of the customer.
B. SETUP ID
• DISPLAY ID
77
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
- ON :The ID name will displayed in the monitor.
- OFF : The name will not displayed in the monitor.
• CAMERA ID : Enter up to 8 characteristic.
• ID POSITION : Select the screen position of the camera ID.
C. LENS
• DC : Use When using DC lens.
• MANUAL : Use When using Manual lens.
D. WDR
• WDR (Wide Dynamic Range) : You can adjust the desired WDR BIAS from -20 to 20 and WDR
RANGE from 0 to 36
E. WB CONTROL
• ATW (Auto Tracking White Balance) : The camera automatically control the white balance in any
environment.
• AWB (Auto White Balance) : The white balance is automatically adjusted in a specific environment.
• MANUAL : Users can adjust the colors by adding or reducing the WB level.
You can adjust the desired WB level from 2K to 11K
F. LOW LIGHT
• SLOW SHUTTER : Control Image brightness by adjusting shutter speed
You can adjust the desired shutter speed from off to X32
- AGC : ON (You can adjust the desired AGC level from 0 to 60dB) or OFF (Deactivate automatic gain
control feature)
• AUTO D/N : AUTO DAY/NIGHT
G. SPECIAL
• VIDEO : NTSC or PAL SELECTION
• FLIP : HORIZONTAL REVERSE (OFF or ON)
• SYNC
- INTERNAL : Internal synchronization
- INTERNAL2 : Internal synchronization (Color Rolling Mode)
- LINE LOCK : Phase adjustment may be necessary in multiple camera installations to prevent picture
roll
when switching between cameras
• BACK LIGHT : BACK LIGHT ADJUST or SELECT AREA
• RESOLUTION : Select Resolution of CCD or PIXIM
• COLOR MODE : COLOR or B/W SELECTION
78
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
• SHARPNESS : ON (You can adjust the desired Sharpness form -8 to 8) or OFF
H. EXIT MENU
• EXIT NO CHANGES : No change
• SAVE NEW AND EXIT : Save change
• RESTORE FACTORY SETTINGS : Factory default
• RELEASE VERSION
I. PREVIOUS PAGE
• PREVIOUS PAGE : Return page
5.2.5. Operating Camera OSD Menu (IP-SD10X)
MAIN MENU
DOME SETUP
CAMERA SET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
* Use the the five keys on the WebViewer GUI “up down” to move the position and
“left right” to make selection
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
A. Dome Setup
To enter Dome setup, use the five keys right to move when cursor on dome setup.
DOME SET
CAMERA ID : CAM1□□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 100°/S
AUTO FLIP : OFF
ZOOM SPEED : FAST
DEFAULT SETTING
ALARM
: DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
A-1.
DOME SET - CAMERA ID
To set camera ID, select up to 16 characters using Five keys to the left or right.
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
A-2.
DOME SET - RECOVER
This feature allows the dome to work from the last setting before you use the dome
manually
(Auto scan, group tour, preset, pattern or sectors) , after the set time, even power shut
down and it turns on again. Recover time can be programmed from 15 second to 99
seconds. The default setting is OFF.
A-3. DOME SET - MANUAL SPEED
Manual Speed of Pan/Tilt is selectable from 100°/sec up to 150°/sec. The default
setting is 100°/sec
A-4. DOME SET - AUTO FLIP
Auto Flip is available and the default setting is OFF. Move five keys “right or left” to
80
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
select ON or OFF. The default setting is OFF.
A-5. DOME SET – ZOOM SPEED
Zoom speeds are selectable FAST or SLOW mode. Move five keys to the right
direction for selecting FAST or SLOW. The default setting is FAST.
A-6. DOME SET – ALARM
All alarms are available after set as ENABLE Mode. Move five keys to right or left
direction for selecting ENABLE/DISABLE. The default setting is DISABLE.
A-7. DOME SET – LANGUAGE
Multiple languages are selectable here including English, Italian and Polish. Move five
keys to the right or left direction to select language. The default setting is ENGLISH.
A-8. DOME SET – [NEXT PAGE]
DOME SET
SYSTEM LOCK: : OFF
[PASS WORD]
DEFAULT SETTING
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
A-8-1. DOME SET – [NEXT PAGE] – SYSTEM LOCK
Password protection provides keeping memorized data. It cannot be adjusted by
anybody without password. In order to enter [PASS WORD] page, system lock status
is must set as ON. Move five keys to right or left direction to select ON. The default
setting is OFF.
A-8-2. DOME SET – [NEXT PAGE] – [PASSWORD]
To enter this page to set a password, move five keys to the right direction. The
password must be set by preset number from 001 to 255 (Default 99)
81
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.2.1. OSD MAIN MENU TABLE (PAGE 54) The default setting is BLANK.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***
Press any number from 001~255 with preset button on password blank and again it on
confirm blank. Then “CONFIRMED” is displayed on the monitor and the menu will go
back to the previous page automatically.
ENTER PASSWORD
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CONFIRMED
CONFIRM ***CANCELLED
<CONFIRMED>
<CANCELLED>
If user presses wrong preset number between PASSWORD and CONFIRM,
“CANCELLED” is displayed on the monitor and if user failed 3 times, the menu will
return to the previous page automatically * After setting a Password, an operator must
press memorized password in order to enter OSD MAIN MENU, or to change the data
which is memorized originally.
* An operator must remember the password for the operation. Manufacturer doesn’t
provide a memorized password.
A-8-3. DOME SET – [NEXT PAGE] – [OSD DISPLAY]
OSD ID displayed after set ON in here and it can be hiding if selected OFF. Move five
keys to the right or left direction in order to select OFF/ON when the cursor is located
each item.
82
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
OSD DISPLAY
CAMERA ID
PRESET ID
SECTOR ID
COORDINATE
[PREVIOUS PAGE]
: OFF
: OFF
: OFF
: ON
DEFAULT SETTING
A-8-4. DOME SET – [NEXT PAGE] – [SYSTEM STATUS]
This page shows the information of this camera.
SYSTEM STATUS
PROTOCOL : PELCO D, P
BAUD RATE
: 2400 BPS
: 2.00
: 06.07,22
: SDM100
DEFAULT SETTING
FIRMWARE VER.
UPGRADED DATE
CAMERA MODULE
[PREVIOUS PAGE]
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 29, 30 and 31)
- Firmware version and upgraded date will be changed if upgraded.
- Below camera modules can be set as follows.
SDM100 : SAMSUNG 10X ZOOM CAMERA MODULE.
EN300
: OPTICAL 3X MODULE (PAN FOCUS)
: Board Camera ( with Fixed Lens)
A-8-5. DOME SET – [NEXT PAGE] – [INITIALIZATION]
To clear all memorized data for tour, preset, sector, privacy or pattern, move five keys to
the right direction when the cursor is on [INITIALIZATION]
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
INITIALIZATION
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT]
[PREVIOUS PAGE]
- To clear memorize any data, move five keys to the right direction when cursor is on
each item.
TOUR CLEAR
ARE YOU SURE? YES NO
TOUR CLEAR
Press FOCUS NEAR button when the cursor is at YES in order to clear memorized
data. Then flickered each item such as tour, preset, sector and so on is displayed on
the monitor about 2~3 seconds. After this process, the menu is returned to the
previous page.
* [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN CLEAR] are
same as [TOUR CLEAR].
LOAD OPTIMIZED DEFAULT
ALL DATA INITIALIZING
ARE YOU SURE? YES NO
- To clear all data and wants returning to factory default, move five keys to the right
direction when cursor is at [LOAD OPTIMIZED DEFAULT] to enter the above page.
- Move five keys to the right or left direction in order to select YES, press FOCUS
NEAR button.
- Then “ALL DATA INITIALIZING” is displayed about 5~7 seconds and then the menu is
returned to the previous page automatically.
84
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
A-9. DOME SET – [NEXT PAGE] – SAVE AND EXIT
To saving the memorized data and escape this page, move five keys to the right
direction when cursor is at SAVE AND EXIT.
A-10. DOME SET – [NEXT PAGE] – EXIT
In order not to save any data and wants to escape this page, move five keys to the right
direction when cursor is at EXIT
B. CAMERA SET
CAMERA SET
CAMERA SET
FLICKER : OFF
MIRROR : OFF
APERTURE : 10
FLICKER
: OFF
: OFF
D ZOOM : OFF
WB MODE : AWB MODE
PIC FLIP : OFF
BLC
EXIT
BLC
: OFF
D/N MODE : AUTO
DSS MODE : OFF
EXIT
<TS-PTZ10X>
< TS-PTZ3X >
B-1. CAMERA SET - FLICKERLESS
Flickerless feature is selected between 50Hz and 60Hz. The default setting is OFF
(NTSC: 60Hz / PAL: 50Hz). Set flicker mode ON when power source is in discord with
frequency. The default setting is OFF
B-2. CAMERA SET - MIRROR
This feature shows left and right exchanged picture image like mirror. The default
setting is OFF.
(10X Zoom)
85
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
B-3. CAMERA SET – APERTURE
Aperture enhances picture details by increasing gain of the caemra and sharpens the
edges in the picture. The default seeting is 10. (the aperture level is from 01 ~ 15)
(10X Zoom)
B-4. CAMERA SET – D ZOOM
Move five keys to the right direction in order to set as ON, if Digital Zoom is necessary
at install field. The default setting is OFF.
(10X Zoom)
B-5. CAMERA SET – WB MODE
White balance functions have 4 modes according to the condition of exterior lighting.
The default setting is AWB and it may change the mode option accoding to the lighting
conditions as below.
AWB Mode – 3,200°K to 6, 000°K (10X Zoom)
ꢅ
ꢅ
ꢅ
Indoor – up to 3,200°K
Outdoor – up to 5,800°K
ATW Mode - 2,000°K to 10, 000°K
B-6. CAMERA SET – PIC FLIP
Picture flip feature provides the top and down exchanged picture image horizontally.
Move five keys to the right or left direction to select OFF/ON. The default setting is
OFF.
(10X Zoom)
B-7. CAMERA SET – BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
OFF – Backlight compensation is not activated.
ON – Back light compensation is activated.
B-8. CAMERA SET – D/N MODE
ICR filter is changeable according to the lighting, AUTO – NIGHT MODE – DAY MODE.
The default setting is AUTO MODE.
86
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
(10X Zoom)
B-9. CAMERA SET – DSS MODE (DIGITAL SLOW SHUTTER)
If DSS turns on, digital slow shutter is working. Per second, the electronic shutter will
remain open to receive some more lighting.
(10X Zoom)
B-10. CAMERA SET – EXIT
To escape this page, move five keys to the right direction.
C. PRESET SET
To enter PRESET SET, move five keys to the right direction.
PRESET SET
PRESET NO :001
PRESET ID :PRESET001-------
PAN :XXX.XX TILT : XXX.XX
SAVE
EXIT
DEFAULT SETTING
C-1.
PRESET – PRESET NO.
Up to 165 numbers of preset positions are available. Move five keys to the right or left
direction to select preset no.
C-2. PRESET – PRESET ID
To set preset ID, select up to 16 characters using Five keys to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right
direction and ZOOM WIDE button moves to the next character from the right to left
direction
(Space displays when appears)
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
C-3. PRESET – PAN: XXX.X TILT: XX.X
Press FOCUS FAR button in order to set preset position then, use the five keys to the
position where memorized preset no. is needed. Then press FOCUS FAR button again
after setting a preset location.
C-4. PRESET – SAVE
Move five keys to the right direction when the cursor is at SAVE and then the cursor will
be located on Preset ID for the continuous preset No. setting.
C-5. PRESET – EXIT
To escape this page, move five keys to the right direction.
D. AUTO SCAN SET
AUTO SCAN SET
START ANGLE
XXX.X.XX.X
END ANGLE
XXX.X.XX.X
DIRECTION
:
:
DEFAULT SETTING
: CW
ENDLES
SPEED
DWELL TIME
: OFF
: 10°/S
: 03
SAVE AND EXIT
D-1. AUTO SCAN- START ANGLE
To set start angle, press FOCUS FAR button then move five keys to the starting angle
which is needed memorized. To press FOCUS FAR button again is to escape.
D-2. AUTO SCAN- END ANGLE
To set end angle, press FOCUS FAR button then move five keys to the starting angle
which is needed memorized. To press FOCUS FAR button again is to escape.
D-3. AUTO SCAN – DIRECTION
Auto Scan directions are available with two direction as CW or CCW by five keys to the
88
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
right or left direction
CW: Clock wise direction (Default)
CCW: Count Clock Wise Direction.
D-4. AUTO SCAN – ENDLESS
Auto Scan can use endless rotation, move five keys to the right direction in order to
select ON. Otherwise, the default setting is OFF.
D-5. AUTO SCAN – SPEED
User can use auto scan speed from 05°/S up to 35°/S and the default setting is 10°/S
D-6. AUTO SCAN – DWELL TIME
To select dwell time, move five keys to the left or right direction in order to adjust dwell
time. Possible to set from 01 second to 30 seconds and the default setting is 03
seconds.
D-7. AUTO SCAN – SAVE AND EXIT
To saving the memorized data and escape this page, move five keys to the right
direction when cursor is at SAVE AND EXIT.
D-8. AUTO SCAN – EXIT
To escape this page, move five keys to the right direction.
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
E. TOUR SET
8 Programmable tours can be set and each tour is available to set up to 64 preset steps.
TOUR SET
TOUR NO : 01
TOUR TITLE : TOUR01□□□□□□□□□□
DEFAULT SETTING
TOUR STEP : 01
PRESET NO. : 01
DWELL TIME : 03
SPEED : 200°/S
SAVE
EXIT
E-1. TOUR SET – TOUR NO.
Max. 8 group tour no. set by the five keys are available.
E-2. TOUR SET – TOUR TITLE
To set tour title, select up to 16 characters using Five keys to left or right.
Press ZOOM TELE button to move the next character from the left to the right direction
and ZOOM WIDE button to move the next character from the right to left direction
(Space displays when appears) Tour title is not displayed on the monitor, but only
for the reference of user.
E-3. TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed. It
is possible to match any preset # for each tour step.
E-4. TOUR SET – PRESET NO.
The decided tour step #1 ~64, it is possible to select any preset no. up to 64. The
default setting is BLK
E-5. TOUR SET – DWELL TIME
Dwell time provides up to 99 seconds from 01 second. The default setting is 03
seconds.
90
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
E-6. TOUR SET – SPEED
Each tour step can be set with different tour speed up to 200°/S and it is selectable
from 10°/S. Move five keys to the right or left direction to select tour speed. The
default setting is 200°/S.
E-7. TOUR SET – SAVE
To save the memorized data and escape this page, move five keys to the right direction
when cursor is at SAVE
E-8. TOUR SET – EXIT
To escape this page, move five keys to the right direction
F. PRIVACY SET
Privacy function is provided by (10X Zoom) only.
4 Privacy masking zones are available to block out areas of security.
PRIVACY SET
PRIVACY NO
DISPLAY
: 01
: OFF
: MOVE
DEFAULT SETTING
ACTION
SAVE
EXIT
F-1. PRIVACY SET – PRIVACY NO.
Up to 4 privacy masking zones are available.
F-2. PRIVACY SET – DISPLAY
Move five keys to the right or left direction to set ON in order to show the selectable
block in the center of the monitor. This block appears as a translucent square with
blue color after set ON. The default setting is OFF.
F-3. PRIVACY SET – ACTION(MOVE/ADJUST)
91
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
To set the blocking area, press FOCUS FAR button when the MOVE MODE is
appeared. Then use the five keys to the user defined area in order to set blocking
area. Then press FOCUS FAR button again to escape from MOVE MODE.
To adjust size of blocking area, move five keys to the right or left direction when the
cursor is on ACTION. After move mode changed to ADJUST MODE, press FOCUS
FAR button in order to adjust the size of blocking area. The size of blocking area can
be adjustable by using five keys up down or left right,. After adjusting size of blocking
area, press FOCUS FAR button to escape ADJUST mode.
ꢅ
ADJUST: You can change the masking size by using five keys to the left or right
direction
ꢅ
MOVE: You can move the masking area by using five keys to the left or right
direction (Default)
F-4. PRIVACY SET – SAVE
After setting the privacy masking zone, to save the data, move five keys to the right
direction when the cursor is on SAVE. After saving the data, the cursor moves to
PRIVACY NO.2 automatically to prepare the next privacy masking zone.
F-5. PRIVACY SET – EXIT
To escape this page, move five keys to the right direction
G. PATTERN SET
8 programmable patterns are available with 16 characters of title.
PATTERN SET
PATT NO : 01
PATT TITLE: PATTERN01□□□□□□□
DEFAULT SETTING
DATA FILL : 100%
SAVE
EXIT
G-1. PATTERN SET – PATT NO.
92
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Up to 8 programmable user-defined patterns set by the five keys on the Webviewer
GUI are available.
G-2. PATTERN SET – PATT TITLE
To set PATTERN TITLE, select up to 16 characters using Five keys to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right
direction and ZOOM WIDE button moves to the next character from the right to left
direction (Space displays when appears) Pattern title is not displayed on the monitor,
but only for the reference of user.
G-3. PATTERN SET – DATA FILL
To fill the programming data, press FOCUS FAR button in order to start the data fill up.
Filling data is programmed according to the the five keys on the Webviewer GUI
movement. Press FOCUS FAR button again in order to escape.
G-4. PATTERN SET – SAVE
To saving the filling data, move five keys to the right direction when the cursor is on
SAVE. Then the cursor moves to the PATT NO.02 in order to prepare next pattern no.
G-5. PATTERN SET – EXIT
To escape this page, move five keys to the right direction
93
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
H. ALARM SET
4 Alarm inputs are available and each alarm is activating to presets, group tours or
patterns.
ALARM SET
ALARM NO : 01
ALARM INPUT: OFF
ALARM ACT : 001
SAVE
DEFAULT SETTING
EXIT
H-1. ALARAM SET – ALARM NO.
Up to 4 alarms are selectable by using five keys to the right direction when cursor is
on ALARM NO.
H-2. ALARAM SET – ALARM INPUT
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal
Close)
The default setting is OFF
H-3. ALARAM SET – ALARM ACT
Alarm activates various surveillance modes with Preset number up to 165, Group
tour up to 8, Pattern up to 8. Move five keys to the right or left direction to select any
preset number, group tour no. or pattern no.
H-4. ALARAM SET – SAVE
After setting the alarm input ways and activation, to save the data, move five keys to
the right direction when the cursor is on SAVE. After saving the data, the cursor moves
to Alarm NO.2 automatically to prepare the next alarm.
H-5. ALARAM SET – EXIT
To escape this page, move five keys to the right direction
94
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
* Before activating Alarm, user must set ALARM ENABLE at DOME SET – ALARM –
ENABLE (Refer to page 15)
I. SECTOR SET
Up to 8 programmable sectors are available with 16 characters.
This feature is useful to memory the certain location such as parking zone or so on.
When camera goes through this area, it shows the letter you memorized.
SECTOR SET
Start Position
SECTOR NO : 01
SECTOR ID : SECTOR01□□□□□□□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
End Position
EXIT
DEFAULT SETTING
I-1. SECTOR SET – SECTOR NO.
Up to 8 programmable sectors set by the five keys are available.
I-2. SECTOR SET – SECTOR ID
set SECTOR ID, select up to 16 characters by using five keys to the left or right.
Press ZOOM TELE button to move to the next character from the left to the right
direction and ZOOM WIDE button to move to the next character from the right to left
direction (Space displays when appears)
I-3. SECTOR SET – SECTOR START
To set SECTOR START angle, press FOCUS FAR button then move five keys to the
left or right direction to set the position. To press FOCUS FAR button again is to
escape.
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
I-4. SECTOR SET – SECTOR END
To set SECTOR END angle, press FOCUS FAR button then move five keys to the left
or right direction to set the position. To press FOCUS FAR button again is to escape.
I-5. SECTOR SET – SAVE
After setting the SECTOR position, to save the data, move five keys to the right
direction when the cursor is on SAVE. After saving the data, the cursor moves to
SECTOR NO.2 automatically to prepare the next SECTOR.
I-6. SECTOR SET – EXIT
To escape this page, move five keys to the right direction
J. EXIT
To escape OSD Main Menu, move five keys to the right or left direction then this
camera is ready to operate.
96
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.2.6.
Mini Speed Dome camera provides up to 63 camera ID and it’s adjustable ID with 1st~6th of
Dip switch
DIP SW SETTING
Open the camera case, set ID using DIP SW1.
* Factory default: Camera ID = 1, PELCO-D
Termina
Baud
Proto
ID Set
5.2.7. ID SETTING(1-ON, 0-OFF)(1ꢂ10)
DIP SW
ID VALUE
DIP SW
ID VALUE
DIP SW
ID VALUE
100000XXXX
010000XXXX
110000XXXX
001000XXXX
101000XXXX
011000XXXX
111000XXXX
000100XXXX
100100XXXX
010100XXXX
110100XXXX
001100XXXX
101100XXXX
011100XXXX
111100XXXX
000010XXXX
1
2
111010XXXX
000110XXXX
100110XXXX
010110XXXX
110110XXXX
001110XXXX
101110XXXX
011110XXXX
111110XXXX
000001XXXX
100001XXXX
010001XXXX
110001XXXX
001001XXXX
101001XXXX
011001XXXX
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
101101XXXX
011101XXXX
111101XXXX
100011XXXX
100011XXXX
010011XXXX
110011XXXX
001011XXXX
101011XXXX
011011XXXX
111011XXXX
000111XXXX
100111XXXX
010111XXXX
110111XXXX
001111XXXX
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
3
4
5
6
7
8
9
10
11
12
13
14
15
16
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
100010XXXX
010010XXXX
110010XXXX
001010XXXX
101010XXXX
17
18
19
20
21
111001XXXX
000101XXXX
100101XXXX
010101XXXX
110101XXXX
39
40
41
42
43
101111XXXX
61
62
63
011111XXXX
111111XXXX
011010XXXX
22
001101XXXX
44
5.2.8.
7th~8th dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P ( Auto detection)
PROTOCOL
DIP SW1- 7
OFF
DIP SW1- 8
OFF
Pelco-D or Pelco-P
5.2.9. BAUD RATE SETTING
The 9th Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps.
DIP SW1 9th
BAUD RATE
2400
OFF
ON
9600
98
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.3.
Use of IP Setting Utility
Upon running IP Setting Utility, the following program is to be displayed.
Fig. 5―2 IP Find
Click ‘IP Find’ Button to find IP of THE CAMERA on local Network.
Fig. 5―3 Display IP
The following window shows list of IP along with Web Server Port Number and Model Name of THE
CAMERA. Click ‘IP Find’ Button to find IP of THE CAMERA on local Network.
99
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―4 IP Check
After finding IP, double-click IP of THE CAMERA to go to the editable Mode as follows.
Fig. 5―5 IP Check
Input new IP Address, Default Gateway, Subnet Mask, and then input Password of THE CAMERA
Administrator and click ‘IP Change’, to set up new IP of THE CAMERA. Upon completion of setting,
find new IP and click ‘Ping’ to check whether setting is done, and close the program by clicking
‘End’ button.
100
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.4.
Use of Service Server
Run Web Browser and input http://ipcam4u.net in URL and click ‘Enter’, then [5-6] will appear
as follows.
Fig. 5―6 Service Server
Click the language user want to use.
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
5.4.1. User Registration
Fig. 5―7 User Login
Click ‘Register Now’ in [5-7].
Fig. 5―8 Agreement
102
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Read the Agreement carefully and click ‘Agree’ in case to agree, and go to the next page.
Fig. 5―9 User Registration
The part marked with (*) is mandatory. User ID is to be double-checked. Then click ‘Log In’.
Fig. 5―10 User Registered
If [5-10] appears, User Registration has successfully completed. Click ‘Log-in’ and input User ID
103
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
and password on [5-7] to connect to Service Server.
Fig. 5―11 Service Server Log-in Succeeded
5.4.2. Camera Registration
Click ‘To register camera’ in [5-11] to go to Camera Registration Page.
①
②
③
④
Fig. 5―12 Camera Registration
Input name of THE CAMERA in ① of [5-12], which will be applied only in Service Server.
② Server Name is to input Domain Name to connect to THE CAMERA. Make this name easy to
remember because you can use it to connect to THE CAMERA by Domain Name in case not
104
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
knowing IP address of THE CAMERA. Domain Name must be unique. Register after checking if it
is duplicate or not.
③ is to check whether the Camera is to be open or not. ④ is for the function to connect to
THE CAMERA easily by User’s ID and Password registered in THE CAMERA, to monitor or control
Video of THE CAMERA on Mobile Phone. (Mobile Phone Users should tick “Enable” and input
connection ID and Password.)
‘EMAIL SERVICE’ is the function to send the set message to E-mail address set by user upon
alarm on THE CAMERA in case user set the use of alarm server as Enable. (refer to ‘Alarm Setting’
in ‘4. Expert Setting’). It’s available to input up to 5 Mail address and input up to 5 messages
upon checking on ‘ENABLE’.
Fig. 5―13 Camera Registration
‘SMS SERVICE’ is the function to send the set message (SMS) from Service Server to Mobile
Phone number set by user upon alarm on THE CAMERA, in case setting to use Alarm Server as
‘ENABLE’. (refer to ‘Alarm Setting’ of ‘4. Expert Setting’). It’s available to input up to 5 Mobile
Phone to get SMS Message and input up to 5 messages upon checking on ‘ENABLE’.
Cautions : Input Mobile Phone Number without ‘-‘.
Click ‘Camera Registration’ to save the registered information after input of all information.
5.4.3. List of Camera
Input the registered User ID and Password to connect to Service Server on [5-7].
105
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―14 Camera List
[5-14] shows the registered List of THE CAMERA. Upon clicking on ‘Camera Name’ registered
in [5-14], [5-15] will show the Camera Information. ‘Time’ is the latest time for THE CAMERA to
report to Service Server.
Fig. 5―15 Camera Information
On clicking ‘Camera Change’ on [5-14], the page of ‘5.3.2 Camera Registration’ to change the
information of Camera registered, will appear. Change the information and click ‘Camera Change’
to save the new information. ‘MAC’ is not changeable. To change ‘Server Name’, double-check is
required. Upon clicking ‘Camera Connect’ on [5-14], the main page of THE CAMERA will appear.
Upon clicking ‘Alarm Log List’ on [5-14], Event information transmitted to Service Server is to be
displayed. Event information is to be saved up to 20. In case of full saving up to 20, it overwrite the
oldest one.
106
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―16 Alarm Log List
‘Alarm Log List’ shows the information of a channel, alarmed time, type of Alarm. It is available to
delete the log file. THE CAMERA sends the recorded files, dividing into Video file and Audio files,
to Service Server
In case there is no recorded file, the message will show ‘No File’. In case the file has not
sent to Service Server yet, the message “Uploading” will be shown. If Video and Audio has been
downloaded in “Download” of [5-16], user can download and see the recorded file. “Camera
Delete” of [5-14] is to delete the Camera from the list..
5.4.4. Change of User’s Information
On clicking ‘User’s Information editing’ in upper menu of [5-14], [5-17] will appear the page to
change user’s information.
107
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―17 Change User’s Information
Save User’s information by clicking ‘To Change Information’ after change user’s information.
5.4.5.
Search Camera
Fig. 5―18 Search Camera
‘Search Camera’ of [5-18] is the function to see information of THE CAMERA or connect directly
to THE CAMERA without user registration in Service Server. Upon clicking ‘Camera Search’ on [5-
18], [5-19] to search Camera will appear. ‘Type’ on [5-19] is to select ‘Camera Connect’ to
connect directly to THE CAMERA using MAC Address, and then to input MAC Address of THE
CAMERA and click ‘Yes’, then THE CAMERA will be directly connected.
108
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―19 Search Camera
If user want to see information of THE CAMERA by the Address, select ‘Information’ and input
MAC Address of THE CAMERA to see information on, and click ‘confirmation’ . Then Information of
THE CAMERA will be shown as [5-20].
5.5.
See and Control of Still Image in Mobile or PDA
To monitor and control of Still Image of THE CAMERA on Mobile Phone, register in ‘Camera
Registration’ of ‘Use of Service Server’ in ‘5. Basic Use’.
Model of Mobile Phone supported is WAP2.0 Phone (HTML, JPEG), PDA (Win CE).
5.5.1. WAP2.0 (HTML)
Connect to URL input line.
Input http://ipcam4u.net/240180.htm or http://ipcam4u.net/320240.htm and connect to Service
Server.
109
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―21 Input User ID
On user ID input Page [5-21], input user’s ID registered in ‘Use of Service Server ’ of ‘5. Basic
Use’.
Fig. 5―22 List of Registered Products
Select one of the products (Camera or Server) registered by user on[5-22].
Fig. 5―23 Menu
Select a item in menu of [5-23].
ꢃ
(1) Monitoring and Control of Pan/Tilt/Zoom/Preset
110
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―24 Pan/Tilt/Zoom Control
It is available to see Image and control Pant/Tilt/Zoom/5 Preset. Number Key of Mobile
Phone controls Pan/Tilt/Zoom.
ꢃ
(2) Relay Control (2 Relay controllable)
It is available to control up to 2 Relay. Relay Name and current status ([ON/OFF]) will
be displayed.
On control of Relay, Image of controlled channel will be shown along with Relay name
of the channel, ON/OFF is to be controllable. On selecting ‘(3) State view’, current
status of 4 Relays will be displayed.
ꢃ
(3) Check Sensor Status
111
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
It shows the Sensor Name and current status ([Normal/Sensing]).
5.5.2. PDA(WinCE)
Run ‘Internet Explorer’ of PDA and input http://ipcam4u.net/pdah5450_eng.htm input in URL to
connect to Service Server.
Fig. 5―25 PDA Log-in
On user ID Input Page [5-25], input user’s ID registered in ‘Use of Service Server ’ of ‘5. Basic
Use’ and click ‘connect’ to log in.
Fig. 5―26 Products List
Select one of the products (Camera or Server) registered by user, in Products List of [5-26].
112
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Fig. 5―27 Menu
5.6.
Use of NVR Program
5.6.1. Required Specification of PC and OS
Item
Min. Requirement
Pentium Ⅳ 2.0G
Recommended Specification
Pentium Ⅳ 2.4G or higher
512MB or higher
CPU
Main Memory
O/S*
256MB
Windows 2000/XP
I.E 5.0
Windows 2000/XP
Web Browser
Resolution
Network
I.E 5.0 or later
1,024 * 768
100 Base-T Ethernet
1,152 * 864
100 Base-T Ethernet
5.6.2. Supported O/S
ꢃ
ꢃ
Windows 2000 Professional (Korean OS, English OS, Japanese OS)
Windows XP Professional / Windows XP Home Edition(Korean OS, English OS,
Japanese OS)
ꢃ
Windows 2000 Server (Korean OS, English OS, Japanese OS)
5.6.3. Refer the NVR User’s Manual in the CD-ROM.
113
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
6. Network Environment
114
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
6.
Network Environment
It is required to follow the recommendation of the environment where THE CAMERA
will be
installed or the similar environment.
6-1.Private line Environment
Usually Company, University, Research center use the leased line. They use many public IP
addresses. In order to install THE CAMERA under this environment, select “Static IP Address” in
‘Static IP Setting’ of ‘3. Basic Setting’ and input IP address, subnet mask and gateway. If there is
DHCP server on the network, select ‘Dynamic IP Address’ in ‘Dynamic IP’ of ‘3. Basic Setting’. You
can get all the information (IP address, subnet mask, gateway, DHCP server) from the network
administrator. Sometimes, the THE CAMERA may not work properly if the user installed firewall for
security purpose. In this case, open the port on the THE CAMERA, then it will work properly. You
can check the current port of THE CAMERA from the “Administrator's Page”->”Network Setting”-
>”Port Setting” (see ‘3. Basic Setting‘). The default port is set on ex-factory as follows :
ꢀ
ꢀ
ꢀ
ꢀ
Web Connection Port
: Port 80 TCP
Authentication and Control Port : Port 9000 TCP
Video Streaming Port
: Port 9001 TCP
: Port 9005 TCP
Motion Detectin Control Port
6-2. Broadband (ADSL, Cable, Fiber Optic) Modem Environment
Home, store, small office use one Broadband modem (DSL, Cable Modem), and use one
public IP address. In order to use several PC through one Public IP address, the user in most cases
use IP sharing device. We recommend to use a IP router (IP Sharing device) to install the THE
CAMERA. There may be a case in no need of router, but most people use THE CAMERA and other
PC 1set or more. When using the router, connect the router and input IP address of THE CAMERA
(IP address of THE CAMERA is set as 192.168.1.7 on ex-factory) in DMZ menu. If the user cannot
use the DMZ function because there is no DMZ menu in the router or some other reasons, go into
port forwarding or NAT menu on the router and map the port of THE CAMERA one by one. User can
check the current port setting of THE CAMERA from “Administrator's Page”->”Network Setting”-
>”Port Setting” (see ‘3. Basic Setting‘). Manufacturer’s setting of THE CAMERA is as follow on ex-
factory : (The user can change port if necessary).
115
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
ꢀ
ꢀ
ꢀ
ꢀ
Web Connection Port
: Port 80 TCP
Authentication and Control Port : Port 9000 TCP
Video Streaming Port
: Port 9001 TCP
: Port 9005 TCP
Motion Detectin Control Port
116
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
7. Appendix
117
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
7.
Appendix
Appendix A Basic Setting Table
Item
Default (Basic Setting)
Remarks
Network Setting
Static IP / Dynamic IP
IP Server
Static IP
Enable
IP Address
192.168.1.7
192.168.1.1
255.255.255.0
80
Gateway
Subnet Mask
Web Connection Port
Authentication /Control Port
Video Streaming Port
Motion Detection Port
ID and Password
Administrator ID /Password
User ID
*. Don’t register the same Port.
*. Register Number with ‘9999’ or less
Some Network may not support over
number 10000 port.
9000
9001
9005
admin/admin
root/root, guest/guest
Domain of Related Server
Domain of Server to connect to
register IP
IP Server
Ipcam4u.net
Ipcam4u.net
Domain of Server to connect to send
Event upon detection of Sensor or
Motion.
Alarm Server
Domain of Server to connect to
download upgraded program
Upgrade Server
Plug-in Download Server
Video Setting
Ipcam4u.net
Ipcam4u.net
Compressed Resolution
Video Format
704*480 / 352*240
NTSC
704*576 / 352*288
PAL
Frame Rate
30fps / 1fps
25fps / 1fps
Bit Rate
VBR_High / VBR_Normal
VBR_High / VBR_Normal
Other Setting
Time Zone
Asia/Seoul(Korea)
*. Note : In case to reset Hardware, Network Setting, User and Administrator’s ID and
Password will be automatically returned to above default value.
118
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Appendix B Specification of Products
B-1 IP-INTB1 / INTB2
Image Sensor
1/3" Sony Super HAD CCD, 410,000 pixels
NTSC
Total Pixel
PAL
811(H)*508(V)
795(H)*592(V)
NTSC
PAL
768(H)*494(V)
Effective
Pixel
755(H)*582(V)
Horizontal resolution
Minimum Illumination
S/N Ratio
540 TV Lines
0.002 Lux(selectable limit ~ X128)
50dB(Weight On)
Lens (INTB1 / INTB2)
Scanning System
Synchronization
Compression
DC AUTO IRIS VF 2.8~10mm(F1.2) / 5~50mm
2:1 Interlaced
Internal
MPEG4 / JPEG
IMAGING
Multi-Streaming
Gain Control
MPEG4(2ch), JPEG(1ch)
On / Off
Electric Shutter Speed
INTENSIFIER
1/60~1/200,000sec
Built-in(selectable Limit ~ X128)
White Balance
ATW / AWC / Manual
Reduce Noise
Low/ Middle/ High/ Off
Maximum Frame Rate
121fps(352*240)
704*480
704*240
Image Sizes
352*480
352*240
Frame Rate
30, 15, 10, 7, 6, 5, 4, 3, 2, 1 fps(10 Steps)
On Screen Display(O.S.D)
Privacy Function
Built-in
ON / OFF (4Programable Zone)
Web Viewer@PC
Yes
PDA Viewer@PC
Yes(option)
Viewer
Program
Viewer@Mobile Phone
NVR@PC
Yes(option)
Yes
Global/Private/Static/Dynamic IP
DDNS Support
Yes
Yes
Network
CONTROL
Encryption (ID/PW/Image)
Interface
Yes
10/100Mbps
Concurrent Users
Manual
20
Yes
Schedule
Yes
Recording
@PC
Motion Detection
Sensor event
Yes
Yes
Sensor Trigger/Motion Detection
Alarm Notification
Yes
Event&
Alarm
SMS/E-MAIL/Alarm Sound(option)
Video Output
Dimension
1.0 Vp-p 75 ohm Composite
69.00mm(H)*73.00mm(W)*300.00mm(L)
Power Source
DC 12V
PHYSICAL
Power Consumption (Max.)
Operational Temperature
Weight
6W
-10 deg - +50 deg C RH95% MAX(14 deg F to 122 deg F)
1.4kg
1
Video Out
Sensor In/Relay Out
Ethernet Jack
Protocols
N/A
CONNECTIVITY
REQUIREMENTS
RJ45(10Base-T/100Base-TX)
HTTP, FTP, SMTP, TCP, IP, DHCP, ICMP, NTP, DNS, DDNS
Internet Explorer® Ver. 6.0+
Windows® 2000/XP
Browser
Operating System
Processor
Intel® Pentium® Ⅲ 1GHz+( P4 2.4Ghz+ recommended)
Memory
256MB+ (512MB+ recommended)
119
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
B-2 IP-INTD3 / INTD4
Image Sensor
1/3" Sony Super HAD CCD, 410,000 pixels
NTSC
PAL
811(H)*508(V)
Total Pixel
795(H)*592(V)
NTSC
PAL
768(H)*494(V)
Effective
Pixel
755(H)*582(V)
Horizontal resolution
Minimum Illumination
S/N Ratio
540 TV Lines
0.002 Lux(selectable limit ~ X128)
50dB(Weight On)
Lens ( INTD3 / INTD4 )
Scanning System
Synchronization
Compression
DC AUTO IRIS VF 2.8~10mm(F1.2) / 5~50mm
2:1 Interlaced
Internal
MPEG4 / JPEG
IMAGING
Multi-Streaming
Gain Control
MPEG4(2ch), JPEG(1ch)
On / Off
Electric Shutter Speed
INTENSIFIER
1/60~1/200,000sec
Built-in(selectable Limit ~ X128)
White Balance
ATW / AWC / Manual
Reduce Noise
Low/ Middle/ High/ Off
Maximum Frame Rate
121fps(352*240)
704*480
704*240
Image Sizes
352*480
352*240
Frame Rate
30, 15, 10, 7, 6, 5, 4, 3, 2, 1 fps(10 Steps)
On Screen Display(O.S.D)
Privacy Function
Built-in
ON / OFF (4Programable Zone)
Web Viewer@PC
Yes
PDA Viewer@PC
Yes(option)
Viewer
Program
Viewer@Mobile Phone
NVR@PC
Yes(option)
Yes
Global/Private/Static/Dynamic IP
DDNS Support
Yes
Yes
Network
CONTROL
Encryption (ID/PW/Image)
Interface
Yes
10/100Mbps
Concurrent Users
Manual
20
Yes
Schedule
Yes
Recording
@PC
Motion Detection
Sensor event
Yes
Yes
Sensor Trigger/Motion Detection
Alarm Notification
Yes
Event&
Alarm
SMS/E-MAIL/Alarm Sound(option)
Video Output
1.0 Vp-p 75 ohm Composite
Dimension ( INTD3 / INTD4 )
Power Source
120.00mm(H)*182.00mm(D) / 150.20mm(H)*180.00mm(D)
DC 12V
PHYSICAL
Power Consumption (Max.)
Operational Temperature
Weight ( INTD3 / INTD4 )
Video Out
6W
-10 deg - +50 deg C RH95% MAX(14 deg F to 122 deg F)
1.4kg / 1.5kg
1
Sensor In/Relay Out
Ethernet Jack
N/A
CONNECTIVITY
REQUIREMENTS
RJ45(10Base-T/100Base-TX)
HTTP, FTP, SMTP, TCP, IP, DHCP, ICMP, NTP, DNS, DDNS
Internet Explorer® Ver. 6.0+
Windows® 2000/XP
Intel® Pentium® Ⅲ 1GHz+( P4 2.4Ghz+ recommended)
Protocols
Browser
Operating System
Processor
Memory
256MB+ (512MB+ recommended)
120
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
B-3 IP-INTT5
IP Camera User’s Manual
Image Sensor
1/3" Sony Super HAD CCD, 410,000 pixels
NTSC
PAL
811(H)*508(V)
Total Pixel
795(H)*592(V)
NTSC
PAL
768(H)*494(V)
Effective
Pixel
755(H)*582(V)
Horizontal resolution
Minimum Illumination
S/N Ratio
540 TV Lines
0.002 Lux(selectable limit ~ X128)
50dB(Weight On)
Lens
C/CS Mount Lens selectable
Scanning System
Synchronization
Compression
2:1 Interlaced
Internal
MPEG4 / JPEG
IMAGING
Multi-Streaming
Gain Control
MPEG4(2ch), JPEG(1ch)
On / Off
Electric Shutter Speed
INTENSIFIER
1/60~1/200,000sec
Built-in(selectable Limit ~ X128)
White Balance
Reduce Noise
ATW / AWC / Manual
Low/ Middle/ High/ Off
Maximum Frame Rate
121fps(352*240)
704*480
704*240
Image Sizes
352*480
352*240
Frame Rate
30, 15, 10, 7, 6, 5, 4, 3, 2, 1 fps(10 Steps)
On Screen Display(O.S.D)
Privacy Function
Built-in
ON / OFF (4Programable Zone)
Web Viewer@PC
Yes
PDA Viewer@PC
Yes(option)
Viewer
Program
Viewer@Mobile Phone
NVR@PC
Yes(option)
Yes
Global/Private/Static/Dynamic IP
DDNS Support
Yes
Yes
Network
CONTROL
Encryption (ID/PW/Image)
Interface
Yes
10/100Mbps
Concurrent Users
Manual
20
Yes
Schedule
Yes
Recording
@PC
Motion Detection
Sensor event
Yes
Yes
Sensor Trigger/Motion Detection
Alarm Notification
Yes
Event&
Alarm
SMS/E-MAIL/Alarm Sound(option)
Video Output
Dimension
1.0 Vp-p 75 ohm Composite
55.4mm(H)*64mm(W)*120mm(L)
Power Source
DC 12V
PHYSICAL
Power Consumption (Max.)
Operational Temperature
Weight
6W
-10 deg - +50 deg C RH95% MAX(14 deg F to 122 deg F)
0.6kg
1
Video Out
Sensor In/Relay Out
Ethernet Jack
Protocols
1/1
CONNECTIVITY
REQUIREMENTS
RJ45(10Base-T/100Base-TX)
HTTP, FTP, SMTP, TCP, IP, DHCP, ICMP, NTP, DNS, DDNS
Internet Explorer® Ver. 6.0+
Windows® 2000/XP
Browser
Operating System
Processor
Intel® Pentium® Ⅲ 1GHz+( P4 2.4Ghz+ recommended)
Memory
256MB+ (512MB+ recommended)
121
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
B-4 IP-T5
IP Camera User’s Manual
Image Sensor
1/3" Panasonic CCD, 410,000 pixels
NTSC
PAL
811(H)*508(V)
Total Pixel
795(H)*592(V)
NTSC
PAL
768(H)*494(V)
Effective
Pixel
755(H)*582(V)
Horizontal resolution
Minimum Illumination
S/N Ratio
480 TV Lines
0.5 Lux
48dB(Weight On)
Lens
C/CS Mount Lens selectable
Scanning System
Synchronization
Compression
Multi-Streaming
ELC
2:1 Interlaced
Internal
MPEG4 / JPEG
MPEG4(2ch), JPEG(1ch)
On / Off
Electric Shutter Speed
BLC
1/60~1/200,000sec
On/Off
MIRROR
On/Off
Maximum Frame Rate
61fps(352*240)
704*480
IMAGING
704*240
Image Sizes
Frame Rate
352*480
352*240
30, 15, 10, 7, 6, 5, 4, 3, 2, 1 fps(10 Steps)
Web Viewer@PC
Yes
PDA Viewer@PC
Yes(option)
Viewer
Program
Viewer@Mobile Phone
NVR@PC
Yes(option)
Yes
Global/Private/Static/Dynamic IP
DDNS Support
Yes
Yes
Network
Encryption (ID/PW/Image)
Interface
Yes
10/100Mbps
Concurrent Users
Manual
20
Yes
Schedule
Yes
Recording
@PC
Motion Detection
Sensor event
Yes
Yes
Sensor Trigger/Motion Detection
Alarm Notification
Yes
Event&
Alarm
SMS/E-MAIL/Alarm Sound(option)
Video Output
Dimension
1.0 Vp-p 75 ohm Composite
55.4mm(H)*64mm(W)*120mm(L)
Power Source
DC 12V
PHYSICAL
Power Consumption (Max.)
Operational Temperature
Weight
6W
-10 deg - +50 deg C RH95% MAX(14 deg F to 122 deg F)
0.6kg
1
Video Out
Sensor In/Relay Out
Ethernet Jack
Protocols
1/1
CONNECTIVITY
REQUIREMENTS
RJ45(10Base-T/100Base-TX)
HTTP, FTP, SMTP, TCP, IP, DHCP, ICMP, NTP, DNS, DDNS
Internet Explorer® Ver. 6.0+
Windows® 2000/XP
Browser
Operating System
Processor
Intel® Pentium® Ⅲ 1GHz+( P4 2.4Ghz+ recommended)
Memory
256MB+ (512MB+ recommended)
122
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
B-5 IP-WDRB1
IP Camera User’s Manual
Image Sensor
1/3" Pixim ORCA CMOS(Dramatic Dynamic range sensor)
742(H)*552(V)
NTSC
PAL
Total Pixel
Horizontal resolution
Minimum Illumination
S/N Ratio
540 TV Lines
0.08Lux (DSS on) with F1.2 Lens
53dB or more
Lens
DC AUTO IRIS VF 2.8~10mm(F1.2)
Scanning System
Synchronization
Compression
525 lines interlaced
Internal
MPEG4 / JPEG
IMAGING
Multi-Streaming
AGC Control
MPEG4(2ch), JPEG(1ch)
0 – 60dB
Electric Shutter Speed
Dynamic range
Maximum Frame Rate
1/60~1/100,000sec
120dB(max), 102dB(typical)
121fps(352*240)
704*480
704*240
Image Sizes
352*480
352*240
Frame Rate
30, 15, 10, 7, 6, 5, 4, 3, 2, 1 fps(10 Steps)
On Screen Display(O.S.D)
Iris Control
Built-in
DC Lens, Manual Lens
Web Viewer@PC
Yes
PDA Viewer@PC
Yes(option)
Viewer
Program
Viewer@Mobile Phone
NVR@PC
Yes(option)
Yes
Global/Private/Static/Dynamic IP
DDNS Support
Yes
Yes
Network
CONTROL
Encryption (ID/PW/Image)
Interface
Yes
10/100Mbps
Concurrent Users
Manual
20
Yes
Schedule
Yes
Recording
@PC
Motion Detection
Sensor event
Yes
Yes
Sensor Trigger/Motion Detection
Alarm Notification
Yes
Event&
Alarm
SMS/E-MAIL/Alarm Sound(option)
Video Output
Dimension
1.0 Vp-p 75 ohm Composite
69.00mm(H)*73.00mm(W)*300.00mm(L)
Power Source
DC 12V
PHYSICAL
Power Consumption (Max.)
Operational Temperature
Weight
6W
-10 deg - +50 deg C RH95% MAX(14 deg F to 122 deg F)
1.2kg
1
Video Out
Sensor In/Relay Out
Ethernet Jack
Protocols
N/A
CONNECTIVITY
REQUIREMENTS
RJ45(10Base-T/100Base-TX)
HTTP, FTP, SMTP, TCP, IP, DHCP, ICMP, NTP, DNS, DDNS
Internet Explorer® Ver. 6.0+
Windows® 2000/XP
Browser
Operating System
Processor
Intel® Pentium® Ⅲ 1GHz+( P4 2.4Ghz+ recommended)
Memory
256MB+ (512MB+ recommended)
123
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
B-6 IP-SD10X
IP Camera User’s Manual
Image Sensor
1/4" Sony Super HAD CCD
No. of Pixel
768(H) * 494(V) 380K
More Than 500TV Lines
0.7Lux (50IRE) / 0.02Lux (ICR On)
2/4/8/16/24/32/64/128/ OFF
10x Optical Zoom(F=3.8 to 38mm)
10x (100x with optical)
Horizontal resolution
Minimum Illumination
Digital Slow Shutter
Optical
Digital
Lens
Luminance S/N Ratio
Compression
More than 50dB
MPEG4/JPEG
IMAGING
Multi-Streaming
WHITE BALANCE
MPEG4(2)/JPEG(1)
AWB/ATW/INDOOR/ OUTDOOR
BLC
Flikerless
ON / OFF
Function
ON / OFF (1/100)
704*480
704*240
352*480
Image Sizes
352*240
Maximum Frame Rate
Frame Rate
121fps (352*240)
30, 15, 10, 7, 6, 5, 4, 3, 2, 1 fps(10 Steps)
CONTROL
Day & Night (ICR)
Auto/ Day/ Night
Rotation Angle
Endless 360'
Pan
Tilt
Manual
Preset
100˚ ~ 150˚/sec
Max 200˚ /sec
0' ~ 90'
Speed
Rotation Angle
Speed
Manual
Preset
100˚ ~ 150˚/sec
Max 200˚ /sec
0.02˚
System Accuracy
165 positions with
position with different speed steps
a
16-character label available for each
Preset Point
Max. 8 Programmable group tours (each one consisting of up
to 60 preset steps with different steps)
Group Tour
Auto scan
Programmable Auto scan
Pattern
8 Programmable Patterns (total 480 seconds)
4 privacy zones
Privacy Zone
Sector
8 selectable Sectors with 16 characters
Yes
Password Protection
Alarm Input
Alarm Actions
Auto Flip
4 alarms OFF/NC/NO (with various programmable states)
Activate preset, Group scanning or Patterns
ON / OFF
OSD Menu
Multiple Languages on screen
Web Viewer@PC
PDA Viewer@PC
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Communication
Protocol
Viewer@Mobile Phone
NVR@PC
Network
Global/Private/Static/Dynamic IP
DDNS Support
Encryption (ID/PW/Image)
124
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Interface
10/100Mbps
Current Users
20
Manual
Yes
Yes
Yes
Yes
Yes
Schedule
Recording@PC
Motion Detection
Sensor event
Sensor Trigger/Motion Detection
Alarm Notification
Event& Alarm
SMS/E-MAIL/Alarm Sound(Option)
Video Output
Dimension
VBS:1.0Vp-p/75 Ohm
158.8φ (D) * 163.0mm(H)
DC12V 1.0A
Power Source
PHYSICAL
Power Consumption (Max.)
Operational Temperature
Weight
12W Max
0'C ~ 50'C
1.7Kg
Video Out
1
RS485 Interface
Sensor In/Relay Out
Ethernet Jack
1/1
2/2
CONNECTIVITY
RJ45(10Base-T/100Base-TX)
HTTP, FTP, SMTP, TCP, IP, DHCP,
ICMP, NTP, DNS, DDNS
Protocols
Browser
Internet Explorer® Ver. 6.0+
Windows® 2000/XP
Operating System
Processor
Memory
REQUIREMENTS
Intel® Pentium® Ⅲ1GHz+ (P4 2.4Ghz+ recommended)
256MB+ (512MB+ recommended)
Appendix C To solve problem
C-1 Basic Check-point
C-1-1Booting
ꢅ
Check if power plug is connected correctly.
C-1-2Network cable (LAN cable) and cable connection check
ꢅ
Check if network cable is straight LAN cable. Hold each end of both side and check if
same color’s cable is connected to same location in RJ-45 jack or not.
Check if network cable connects correctly with THE CAMERA.
Check if network cable connects correctly with Hub, IP sharing device and cable modem
etc….
ꢅ
ꢅ
*. If you found a problem in the product, first check with “C-1 Basic check point” and solve the
problem as following procedures:
C-2 Troubleshooting by type
C-2-1Cannot connect with network
125
Download from Www.Somanuals.com. All Manuals Search And Download.
Speco Technologies
IP Camera User’s Manual
Check with ‘C-1-2 Network Cable (LAN cable) and cable connection check’.
PING Test
ꢅ
ꢅ
ꢆ
In case Camera uses Static/Public IP: input “Ping IP address” to command window
of PC and check response.
ꢆ
In case camera uses dynamic/public IP: In this case, user cannot find camera IP
address. So, reset hardware and connect PC with THE CAMERA through cross cable
and ping test by “192.168.1.7”.
ꢆ
In case camera uses private IP through IP sharing device: Ping-test private IP
address set for THE CAMERA in PC that is connected in the local network through IP
sharing device.
ꢅ
ꢅ
If “ping test” get response, network setting for camera is done correctly.
If ping test is okay but there is no connection, check with ‘C-2-2 check port setting’..
C-2-2. Check Port Setting
ꢅ
If user can’t connect with camera even though ‘Ping test’ is okay, please check port
setting by the following steps.
ꢅ
THE CAMERA uses 3 ports as follow.
ꢀ
ꢀ
ꢀ
ꢀ
Web Connection Port
: Port 80 TCP
Authentication and Control Port : Port 9000 TCP
Video Streaming Port
: Port 9001 TCP
: Port 9005 TCP
Motion Detection Control Port
ꢅ
ꢅ
If it is not available even to connect to web, check web connect port because web
connect port may be set with other number than ‘80’.
In case there is problem in video monitoring even though there is no problem in Web
connection, check if ‘Authentication and Control Port’ and ‘Video Streaming Port’ of THE
CAMERA is set on IP sharing device (in case of using IP sharing device).
For setting of IP sharing device Port, refer to ‘IP sharing device Setting’.
ꢅ
C-3 In case web page can’t be connected under ultrahigh speed internet line
ꢅ
Some ultrahigh ISP company may block not to use Web port number 80. In this case,
change to other number from web connection port setting.
126