Southbend Range S536D User Manual

IMPORTANT FOR FUTURE REFERENCE  
Please complete this information and retain  
this manual for the life of the equipment:  
Model #: __________________________  
Serial #: __________________________  
Date Purchased: ___________________  
Owner’s Manual  
500 Series  
Restaurant Ranges  
Models X536A, X536D, X560AA, X560AD, X560DD  
S536A, S536D, S560AA, S560AD, S560DD  
Model X536D  
Model X560DD  
WARNING  
This appliance shall be installed in conformity with the current regulations and used only in a well ventilated  
location. Consult the instructions before installing and using the appliance.  
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.  
Read installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.  
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526 USA • www.southbendnc.com  
OWNERS MANUAL 1188716 (02/07)  
$21.00  
500 SERIES RESTAURANT RANGES  
MANUAL SECTION RR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
INTRODUCTION  
INTRODUCTION  
Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the  
market.  
You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to meet  
the toughest standards in the industry. Each piece of Southbend equipment is carefully engineered and designs are  
verified through laboratory tests and field installations. With proper care and field maintenance, you will experience  
years of reliable, trouble-free operation. For best results, read this manual carefully.  
RETAIN THIS MANUAL FOR FUTURE REFERENCE.  
This manual is divided into six sections:  
The serial plate is located on the inside surface of the kick panel (see Figure 1 below).  
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by  
a qualified installer. Unless the installation instructions for this product are followed by a qualified service technician (a  
person experienced in and knowledgeable with the installation of commercial gas and/or electric cooking equipment)  
then the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any  
kind shall apply.  
In the event you have questions concerning the installation, use, care, or service of the product, write to:  
Southbend  
1100 Old Honeycutt Road  
Fuquay-Varina, North Carolina 27526 USA  
Figure 1  
Location of Serial Plate  
Serial Plate is Located on  
Inside Surface of Kick Panel  
OWNERS MANUAL 1188716 (02/07)  
PAGE 3 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SPECIFICATIONS  
500 SERIES RESTAURANT RANGES  
SPECIFICATIONS  
NOTICE  
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,  
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to  
installation requirements for equipment. Therefore, installations should comply with all local codes.  
Southbend reserves the right to change specifications and product design without notice. Such revisions do not  
entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.  
Southbend appliances are intended for commercial use only, not for household use.  
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,  
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-  
B149.2, as applicable, including:  
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during  
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).  
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve  
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45  
kPa).  
CLEARANCES  
WARNING  
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION  
There must be adequate clearance between ranges and combustible construction. Clearance must also be  
provided for servicing and for operation.  
Minimum Clearances:  
Standard Oven  
10 inches  
10 inches  
zero  
Convection Oven  
10 inches  
10 inches  
zero  
Double Oven Base  
10 inches  
Sides  
Back  
Floor  
10 inches  
zero  
Ranges are suitable for installation on combustible floors.  
Adequate clearance must be provided in the aisle and at the side and rear to allow the door to open sufficiently to  
permit the removal of the racks and for serviceability.  
On ranges with a convection-type oven, a minimum of 2 inches clearance must be allowed behind the motor and  
the rear non-combustible enclosure. Care must be taken to provide adequate air circulation to prevent the motor  
from overheating. No additional clearance from the sides and back is required for service as the ranges are  
serviceable from the front.  
DIMENSIONS  
The exterior dimensions of the restaurant range are shown in Figure 2 on the next page.  
PAGE 4 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SPECIFICATIONS  
Figure 2  
Dimensions  
O
Gas Connection  
O
Electrical Connections  
R
R
Electrical Connection  
R
Gas Connection  
A
A
I
I
J
J
K
K
B
B
C
G
F
G
F
E
E
Gas Connection  
Electrical  
Connection  
L
L
P
Q
N
N
M
M
D
Side View of Ranges WITH Convection Oven  
Exterior Dimensions in Inches and (Millimeters)  
D
Side View of Ranges WITHOUT Convection Oven  
Cook Top Door  
Oven  
Bottom  
N
Model Number  
Height  
L
Depth  
M
A
B
C
D
E
F
G
H
I
J
K
36.5"  
(927)  
45.25"  
(1149)  
10"  
(254)  
31.25"  
(794)  
33"  
(838)  
11"  
(279)  
2.75"  
(70)  
59.5"  
(1511)  
22.5"  
(587)  
31.0"  
(787)  
6"  
(152)  
37.0"  
(914)  
15.5"  
(394)  
13"  
(318)  
536A  
536D  
36.5"  
(927)  
36"  
(914)  
31.25"  
(794)  
33"  
(838)  
11"  
(279)  
2.75"  
(70)  
59.5"  
(1511)  
22.5"  
(587)  
31.0"  
(787)  
6"  
(152)  
37.0"  
(914)  
15.5"  
(394)  
13"  
(318)  
-
560AA  
560AD  
60.75"  
(1543)  
45.25"  
(1149)  
10"  
(254)  
31.25"  
(794)  
33"  
(838)  
11"  
(279)  
2.75"  
(70)  
59.5"  
(1511)  
22.5"  
(587)  
31.0"  
(787)  
6"  
(152)  
37.0"  
(914)  
15.5"  
(394)  
13"  
(318)  
60.75"  
(1543)  
36"  
(914)  
31.25"  
(794)  
33"  
(838)  
11"  
(279)  
2.75"  
(70)  
59.5"  
(1511)  
22.5"  
(587)  
31.0"  
(787)  
6"  
(152)  
37.0"  
(914)  
15.5"  
(394)  
13"  
(318)  
560DD  
-
See table on next page for dimensions O, P, Q, and R.  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 5 OF 44  
 
SPECIFICATIONS  
500 SERIES RESTAURANT RANGES  
INTERIOR DIMENSIONS AND UTILITY DATA  
Left (or Only) Oven  
Interior Dimensions  
Right Oven  
Interior Dimensions  
Burners  
(number of and BTU/hour)  
Gas Connection Electric Connect.  
Location  
O* P*  
3.25" 30.25"  
(82) (768)  
3.25" 30.25"  
(82) (768)  
3.25" 30.25"  
(82) (768)  
Location  
Model Number  
Total BTU/hour  
Width Depth Height Width Depth Height  
Open  
Oven  
Q*  
R*  
26.125"  
(664)  
24"  
(610)  
14.25"  
(362)  
6@33,000 Nat  
6@24,000 LP  
1@32,000 Nat  
1@30,000 LP  
230,000 Nat  
174,000 LP  
24"  
6"  
X536A  
X536D  
X560AA  
-
-
-
-
-
-
(610)  
(152)  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
6@33,000 Nat  
6@24,000 LP  
1@45,000 Nat  
1@40,000 LP  
243,000 Nat  
184,000 LP  
-
-
26.125"  
(664)  
24"  
(610)  
14.25" 26.125"  
(362)  
24"  
(610)  
14.25" 10@33,000 Nat  
2@32,000 Nat  
2@30,000 LP  
394,000 Nat  
300,000 LP  
24"  
6"  
(664)  
(362)  
10@24,000 LP  
(610)  
(152)  
1@32,000 and  
1@45,000 Nat  
1@30,000 and  
1@40,000 LP  
26.125"  
(664)  
24"  
(610)  
14.25"  
(362)  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
10@33,000 Nat  
10@24,000 LP  
407,000 Nat  
310,000 LP  
3.25" 30.25"  
(82) (768)  
24"  
(610)  
6"  
(152)  
X560AD  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
10@33,000 Nat  
10@24,000 LP  
2@45,000 Nat  
2@40,000 LP  
420,000 Nat  
320,000 LP  
3.25" 30.25"  
(82) (768)  
X560DD  
S536A  
-
-
26.125"  
(664)  
24"  
(610)  
14.25"  
(362)  
6@27,000 Nat  
6@21,000 LP  
1@32,000 Nat  
1@30,000 LP  
194,000 Nat  
156,000 LP  
3.25" 30.25"  
(82) (768)  
24"  
(610)  
6"  
(152)  
-
-
-
-
-
-
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
6@27,000 Nat  
6@21,000 LP  
1@45,000 Nat  
1@40,000 LP  
207,000 Nat  
166,000 LP  
3.25" 30.25"  
(82) (768)  
S536D  
-
-
26.125"  
(664)  
24"  
(610)  
14.25" 26.125"  
24"  
(610)  
14.25" 10@27,000 Nat  
2@32,000 Nat  
2@30,000 LP  
334,000 Nat  
270,000 LP  
3.25" 30.25"  
(82) (768)  
24"  
(610)  
6"  
(152)  
S560AA  
(362)  
(664)  
(362)  
10@21,000 LP  
1@32,000 and  
1@45,000 Nat  
1@30,000 and  
1@40,000 LP  
26.125"  
(664)  
24"  
(610)  
14.25"  
(362)  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
10@27,000 Nat  
10@21,000 LP  
347,000 Nat  
280,000 LP  
3.25" 30.25"  
(82) (768)  
24"  
(610)  
6"  
(152)  
S560AD  
S560DD  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
26"  
(660)  
26.5"  
(673)  
14"  
(356)  
10@27,000 Nat  
10@21,000 LP  
2@45,000 Nat  
2@40,000 LP  
360,000 Nat  
290,000 LP  
3.25" 30.25"  
(82) (768)  
-
-
* See figure on previous page for location of utility connections.  
VENTILATION  
WARNING  
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products  
can cause headaches, drowsiness, nausea, or could result in death.  
All ranges must be installed in such a manner that the flow of combustion and ventilation air are not obstructed.  
Provisions for adequate air supply must be provided. Do not obstruct the front of the range at the top by the control  
panel, or the bottom just below the oven compartment, as combustion air enters through these areas.  
NOTICE  
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the  
warranty.  
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s  
instructions.  
Canopies are set over ranges, ovens, etc., for ventilation purposes. It is recommended that a canopy extend 6" past  
the appliance and the bottom edge be located 78" above the floor. Filters should be installed at an angle of 45° or  
more from the horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip  
pan, unusually installed with a filter.  
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may  
extinguish pilot flames. Fresh air openings approximately equal to the fan area will relieve such a vacuum.  
The exhaust fan should be installed at least 2" above the vent opening at the top of the range.  
If the range is connected directly to an outside flue, a CSA design-certified down draft diverter must be installed at the  
flue outlet of the oven and connected to the flue.  
PAGE 6 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
SPECIFICATIONS  
In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan in the OFF position.  
Do this only long enough to check equipment performance. Then turn hood back on and let it run to remove any  
exhaust that may have accumulated during the test.  
GAS SUPPLY  
A 3/4" female NPT gas connection is located on the rear of the range (see Figure 2).  
The serial plate is located on the right side of the range (See Figure 1). The serial plate indicates the type of gas the  
range is equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.  
These models are design-certified for operation on natural or propane gases. For natural gas, the regulator is set to 4"  
W.C. (0.99 kPa). For propane gas, it is set to 10" W.C. (2.48 kPa).  
If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance  
with local codes, or in the absence of local codes, with the applicable national codes.  
This appliance should be connected ONLY to the type of gas for which it is equipped.  
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for  
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems  
and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold  
pressure.  
An adequate gas supply line to the range should be no smaller than the inside diameter of the pipe from the range to  
which it is connected.  
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the range.  
All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on all gases.  
NEVER use an open flame to check for gas leaks. All connections must be checked for leaks after the range has  
been put into operation. Test pressure should not exceed 14" W.C. (3.47 kPa).  
ELECTRICAL REQUIREMENTS  
Ranges with a convection oven require connection to a supply of electricity. The appliance, when installed, must be  
electrically grounded in accordance with local codes, or in the absence of local codes, with the applicable national  
codes. An electrical diagram is located on the rear of the range, near the motor.  
Usually the range is furnished with one or two power cords (one for each oven), each with a standard 115V, 60Hz,  
single-phase prong plug. Total maximum power for 115V units is 4.8 amperes.  
The range can be ordered to operate on 208V 60Hz 1-phase or 3-phase current, in which case the electric power  
supply must be wired to one or two junction boxes (one for each oven), each with a terminal block on the rear of the  
range. Total maximum power for 208V units is 2.6 amperes.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 7 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
500 SERIES RESTAURANT RANGES  
OPERATION  
DANGER  
EXPLOSION AND ASPHYXIATION HAZARD  
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call  
the emergency phone number of your gas supplier.  
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the  
flow of combustion and ventilation air to and from cooking appliances.  
CAUTION  
To eliminate gas build up which could result in an explosion, in the event of main burner ignition failure wait five  
minutes before attempting to relight the pilot or burner.  
The controls for the burners and oven(s) are located on the valve panel on the front of the range.  
If the pilots need to be lit, follow the steps listed in each section below.  
LIGHTING AFTER GAS HAS BEEN SHUT OFF  
When turning the main gas supply on after the gas supply has been shut off, do the following:  
1. Make sure the gas supply valve, located on the front valve panel, is in the OFF position.  
2. Make sure all of the control valves are in the OFF position.  
3. Turn on the incoming gas supply.  
4. Turn the gas supply valve, located on the front valve panel, to the ON position.  
5. Light the pilots as described below.  
6. Light the oven first and then wait six minutes before lighting top burners to purge all air from the range.  
OPERATION OF TOP BURNERS  
To operate a top burner, turn the corresponding control knob on the front panel to the desired flame level.  
Each top burner has its own pilot. If a top-burner pilot needs to be lighted, do the following:  
1. Turn all the top-burner control knobs to the OFF position.  
2. On S500 models, turn one of the top-burner control knobs to the pilot position, push the knob inward, and  
hold it in place. Depress and hold down the spark switch (the black button between the control valves). A  
spark from the ignitor to the pilot can be seen and heard. When the pilot lights, release the spark switch, but  
continue holding the knob in for 30 to 45 seconds. When the knob is released, the pilot should remain lit.  
On X500 models, depress and hold down the spark switch (the black button between the control valves). A  
spark from the ignitor to the pilot can be seen and heard. When the pilot lights, release the spark switch.  
3. Repeat step 2 for the all other top-burner pilots that need to be lighted.  
OPERATION OF OVEN  
To operate an oven, turn the oven-thermostat knob on the front panel to the desired temperature. On convection  
ovens, the blower is controlled by an ON-OFF switch.  
Each oven has its own pilot. If an oven pilot needs to be lighted, do the following:  
1. Turn the oven thermostat to the OFF position.  
2. For convection ovens, turn the fan switch to the OFF position.  
3. Open the oven door and remove the oven bottom and fire plate to expose pilot and burner.  
4. Open the kick panel below the oven door and depress red button on oven safety valve.  
5. Light constant pilot (the pilot without a capillary tube holder).  
6. Close the kick panel and replace the fire plate and oven bottom.  
PAGE 8 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
OPERATION  
SHUTDOWN OF ENTIRE RANGE  
To completely shut down the range for an extended period (or prior to disconnecting the gas supply), do the following:  
1. Turn all burner control knobs to OFF.  
2. Turn the oven thermostat knob(s) to the lowest temperature.  
3. Turn the main gas valve on the valve panel to OFF.  
4. Turn-off the gas supply to the oven.  
TROUBLESHOOTING BY OPERATOR  
The following table lists the possible causes and solutions of problems that may occur during operation.  
Problem  
Possible Causes and Solutions  
A top burner will not light.  
– Check pilot position.  
– Check and light the burner’s pilot.  
– Check gas supply to range.  
Oven will not heat up.  
– Check and light the oven pilot.  
– Check gas supply to range.  
Blower of convection oven is not running.  
Pilot(s) will not remain lit.  
– Check that the oven’s blower control switch is in ON position.  
– Check electricity supply to range.  
– Check gas supply to range.  
– Check pilot adjustment.  
If other appliances connected to the same source of gas or electricity are also not operating correctly, the problem is  
likely not within the range.  
If the problem only occurs for the range, and if the above solutions to do not solve the problem, call for repair service.  
TROUBLESHOOTING CONVECTION-OVEN COOKING PROBLEMS  
If…  
then…  
Cakes are dark on the sides and not done in the center…  
Cake edges are too brown…  
Cakes have light outer color…  
Cake settles slightly in the center…  
lower oven temperature.  
reduce number of pans or lower oven temperature.  
raise temperature.  
bake longer or raise oven temperature slightly. Do not  
open doors too often for long periods.  
Pies have uneven color…  
reduce number of pies per rack.  
lower oven temperature and roast longer.  
raise temperature. Limit amount of moisture.  
overloading pans or batter is too thin.  
lower oven temperature.  
Meats are browned and not done in center…  
Meats are well done and not browned…  
Cakes ripple…  
There is excessive meat shrinkage…  
Cakes are too coarse…  
lower oven temperature.  
WARNING  
THE USE OF ALUMINUM FOIL CAN CAUSE HEAT DISTRIBUTION PROBLEMS IN OVENS. EXTREME  
CARE MUST BE USED WHEN PLACING ALUMINUM FOIL IN THE OVEN TO ENSURE THAT IT DOES NOT  
BLOCK OR CHANGE THE AIR FLOW. THE USE OF ALUMINUM FOIL MAY VOID THE PRODUCT  
WARRANTY IF ITS USE IS ASCERTAINED TO BE A PROBLEM.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 9 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
500 SERIES RESTAURANT RANGES  
COOKING TIPS FOR CONVECTION OVENS  
As a guide, set oven temperatures 25 to 50 degrees lower than called for in recipes using conventional (non-  
convection) ovens.  
FROZEN ENTREE PRODUCTS: Punch holes in lid before heating. Tent lid if product has a tendency to stick, i.e.,  
lasagna or macaroni and cheese. Use manufacturer’s convection oven directions for time and temperature or reduce  
conventional oven temperature 50 degrees for a 6-1/2 size pan load. Some products may cook in 10 to 15 minutes  
less time than recommended for convection ovens if prepared from frozen in a 6 pan load.  
Time and temperatures will vary depending upon load, mix, size of portion, and other factors. Use the following chart  
to develop your own cooking techniques:  
Timing  
(minutes)  
Temperature  
Setting  
Number of  
Racks Used  
Count per  
Pan/Rack  
Product  
Hamburger buns, 3 oz. - 4"  
18  
10  
375°  
400°  
2
2
24  
48  
Yeast rolls - 1 oz.  
Use temperature and time recommended by  
manufacturer for convection ovens for a 3 pan load.  
Fruit pies, 46 oz. frozen  
50  
375°  
2
4
Use temperature and time from manufacturer’s directions  
for convection ovens for a 12 pie load placed on 3 bun  
pans.  
Egg custard pies, 44 oz. frozen  
Dutch apple pies, 46 oz. frozen  
60  
50  
60  
325°  
350°  
400°  
2
2
2
4
4
Baked potatoes, 8 oz.  
30 (wrapped)  
Wash and wrap in potato foil. Place 30 potatoes on 18 x  
24 bun pan — 3 pans per load. Bake in 400°F oven for 1  
hour.  
Pre-blanched potatoes, frozen  
Spread on ungreased bun pans, 3 pans per load. Bake  
at 400°F, stirring once, for 15 to 18 minutes.  
16  
16  
400°  
400°  
2
2
5 lb.  
32  
Fish portions, pre-cooked, breaded, 3 oz.  
Use manufacturer’s recommended temperature and time  
for convection oven for a 3 pan load.  
Macaroni & cheese, 6 lbs. - 40° temp.  
Lasagna w/meat sauce, 6 lb. - 40° temp.  
Lasagna w/meat sauce, 6 lb. - frozen  
Salisbury steak w/gravy, 6 lb. - 40° temp.  
45  
60  
75  
45  
400°  
350°  
350°  
400°  
2
2
2
2
2-6 lbs.  
2 - 6 lbs.  
2-6 lbs.  
2-6 lbs.  
Top round of beef No. 168  
14 lb. - rare  
140° internal  
14 min./lb.  
250°  
250°  
250°  
1
1
1
1 - 2  
1 - 2  
1 - 2  
14 lb. - medium  
14 lb. - well done  
150° internal  
14 min./lb.  
160° internal  
14 min./lb.  
PAGE 10 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
CLEANING & MAINTENANCE  
CLEANING & MAINTENANCE  
WARNING  
Shut off the range and allow time for it to cool before cleaning or performing maintenance.  
Southbend appliances are sturdily constructed of the best materials and are designed to provide durable service when  
treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and  
cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usage.  
Following daily and periodic maintenance procedures will enhance long life for your equipment. Climatic conditions  
(such as salt air) may require more thorough and frequent cleaning or the life of the equipment could be adversely  
affected.  
Keep exposed, cleanable areas clean at all times.  
DAILY CLEANING  
1. Turn all controls to OFF and allow time for the range to cool.  
2. Remove, empty, and clean drip trays.  
3. Wipe clean all cooking surfaces.  
CLEANING OVEN INTERIOR  
WARNING  
FOR YOUR SAFETY, BEFORE CLEANING A CONVECTION OVEN DISCONNECT THE POWER SUPPLY.  
WHEN CLEANING THE BLOWER WHEEL, BE SURE THAT THE POWER SWITCH IN THE “OFF” POSITION.  
Allow oven to cool. Remove porcelain enameled oven bottom. Clean by rubbing with strong detergent and Brillo pad  
or similar scrubber. “Spill-overs” should be cleaned from the bottom as soon as possible to prevent carbonizing and a  
“burnt-on” condition. For stubborn accumulations, commercial oven cleaners are recommended.  
The porcelain oven door lining can be cleaned in a similar manner.  
The side, rear and top lining should be wiped only with a cloth dampened with a mild detergent and water. Avoid using  
excessive amounts of water, as this may drip into burner compartment and deteriorate the metal in that area. Do not  
use strong commercial cleaners or abrasive pads on the side, rear or top linings, as they may damage the finish or  
leave gray residue.  
PERIODIC CLEANING AND MAINTENANCE  
At least monthly, clean around burner air mixers and orifices if lint has accumulated and visually check proper pilot  
operation.  
At least twice a year, examine and clean the range hood and venting system.  
If range-top spillage should occur, it may be necessary to clean around pilot areas, air mixer, and under burners. Use  
a wire brush if necessary.  
If any burners become clogged, remove and clean them. Allow interior to drain. Dry thoroughly before replacing.  
BLUE BAKED-ENAMEL SURFACES  
Wash exterior blue baked-enamel surfaces with a hot, mild detergent or soap solution to clean off all grease deposits.  
Dry thoroughly with a dry cloth.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 11 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLEANING & MAINTENANCE  
500 SERIES RESTAURANT RANGES  
STAINLESS-STEEL SURFACES  
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature,  
use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean  
cloth.  
To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and  
rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible,  
in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR  
MOTION. Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing  
the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL  
WOOL as any particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A  
WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS.  
Surfaces which are marred collect dirt more rapidly and become more difficult to clean. Marring also increases the  
possibility of corrosive attack. Refinishing may then be required.  
“Heat tint” is darkened areas that sometimes appear on stainless steel surfaces where the area has been subjected to  
excessive heat. These darkened areas are caused by thickening of the protective surface of the stainless steel and  
are not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure  
calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS  
scouring pad in combination with a powered cleanser. Heat tint may be lessened by reducing heat to equipment  
during slack periods.  
BRIGHT-ANNEALED STAINLESS-STEEL SURFACES  
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature,  
use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean  
cloth.  
Never use any abrasive cleaner, pad, wire brush, scrapper, or file to remove material from the bright-annealed  
surfaces.  
PAGE 12 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
INSTALLATION  
INSTALLATION  
NOTICE  
These installation procedures must be followed by qualified personnel or warranty will be void.  
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,  
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to  
installation requirements for equipment. Therefore, installations should comply with all local codes.  
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,  
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-  
B149.2, as applicable, including:  
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during  
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).  
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve  
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45  
kPa).  
NOTICE  
EXHAUST FANS AND CANOPIES: It is recommended that the range be installed under a ventilation hood.  
Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem  
due to improper ventilation will not be covered by warranty.  
NOTICE  
In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation  
hoods shall comply with 248 CMR interlocking requirements.  
STEP 1: UNPACKING  
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE  
All containers should be examined for damage before and during unloading. The freight carrier has assumed  
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a  
claim must be made with the delivering carrier.  
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be  
signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier  
can supply the necessary forms.  
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not  
apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all  
contents plus all packing material.  
Do the following:  
1. Cut the banding straps and remove the corrugated cardboard surrounding the range. If legs were shipped in  
the same container, set them aside for installation in later steps of this procedure. Do not remove any tags or  
labels attached to the range until the range is installed and working properly.  
2. Lift the flue riser off the front of the skid (see Figure 3) and set it aside for installation later in this procedure.  
3. Pull the shelf assembly out from under the base and set it aside for installation later in this procedure.  
4. Unbolt the shipping hold-down brackets from the skid, then remove the brackets from the range.  
5. If the range is to be installed on legs, go to Step 2a.  
If the range is to be installed on casters, go to Step 2b.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 13 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION  
500 SERIES RESTAURANT RANGES  
Figure 3  
Unpacking  
Base  
Shelf  
Flue Riser  
Skid  
STEP 2A: ATTACH LEGS  
A set of four legs is packed with ranges ordered with legs. (For ranges ordered with casters, go to Step 2b.)  
A threaded leg pad is fastened to the base frame at each corner. Each leg has a corresponding mating thread. The  
legs can be adjusted to overcome a slightly uneven floor.  
1. Raise range sufficiently to allow leg pads and legs to be attached. For safety, “shore up” and support the range  
with an adequate blocking arrangement strong enough to support the load.  
2. Attach the four leg pads to the bottom of the range using the lock washers and machine screws. The  
mounting holes are pre-drilled and threaded.  
3. Screw the legs into the holes in the centers of the leg pads.  
4. Lower range gently onto a level surface. Never drop or allow the range to fall.  
5. Use a level to make sure that the range surface is level. The legs can be screwed in or out to lower or raise  
each corner of the range.  
6. Go on to Installation Step 3.  
Figure 4  
Installation of Legs  
PAGE 14 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
INSTALLATION  
STEP 2B: ATTACH CASTERS AND RESTRAINT  
NOTICE  
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with  
the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas  
Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-  
Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel,  
CAN1-6.9, (2) adequate means must be provided to limit the movement of the appliance without depending on  
the connector and the quick-disconnect device or its associated piping to limit the appliance movement, and (3)  
the restraining means should be attached to a frame member on the back of the unit.  
A set of four casters is packed with ranges ordered with casters (instead of legs).  
A threaded leg pad is fastened to the base frame at each corner. Each caster has a corresponding mating thread. The  
casters can be adjusted to overcome a slightly uneven floor. Casters are provided with a Zerk fitting for proper  
lubrication when required.  
1. Raise range sufficiently to allow leg pads and casters to be attached. For safety, “shore up” and support the  
range with an adequate blocking arrangement strong enough to support the load.  
2. Attach the four leg pads to the bottom of the range using the lock washers and machine screws. The  
mounting holes are pre-drilled and threaded.  
3. Screw the casters into the holes in the centers of the leg pads. Install the casters that have a locking brake  
under the front of the range.  
4. Lower range gently onto a level surface. Never drop or allow the range to fall.  
5. Use a level to make sure that the range surface is level. The casters can be screwed in or out to lower or raise  
each corner of the range. After the range has been leveled, tighten the lock nuts.  
Figure 5  
Installation of Casters  
6. Secure the restraining-device bracket (item “B” in the following illustration) to a wall stud located as close as  
possible to the appliance connector inlet and outlet connections. Use four #12 screws (items “C”) and plastic  
anchors (items “A”) if necessary.  
7. Install eye-bolt (item “F”) to a frame member on the rear of the equipment. After checking carefully behind the  
frame member for adequate clearance, drill a 7 mm hole through the frame member.  
8. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through the 7  
mm drilled hole and secure with a washer (item “H”) and nylon lock nut (item “I”).  
9. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 15 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
500 SERIES RESTAURANT RANGES  
10. Using the cable clamp (item “D”), adjust the restraining device extended length to prevent over-bending or  
kinking of the appliance connector.  
Figure 6  
Installation of Restraint  
A
D
E
F
H
C
B
G
I
Be sure all controls are turned off prior to disconnecting. After reconnecting, be sure all controls are turned off and all  
pilots are lit.  
NOTICE  
Adequate means must be provided to limit the movement of the appliance without depending on the connector  
and the quick-disconnect device or its associated piping to limit the appliance movement.  
The restraining means should be attached to a frame member on the back of the range.  
PAGE 16 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
INSTALLATION  
STEP 3: ATTACH FLUE RISER AND SHELF ASSEMBLY  
Place the flue riser assembly on the range as shown on the appropriate diagram below.  
1. Slide the flue riser assembly over the bayonets until it bottoms out, as shown below.  
2. Secure ends of flue riser assembly with two (2) 1/4-20 x 3/4 hex head bolts, flat washers and lockwashers  
3. Attach the shelf assembly to the flue riser assembly.  
Figure 7  
Installation of Flue Riser and Shelf Assembly  
Single-Oven Models  
Dual-Oven Models  
STEP 4: ELECTRICAL CONNECTION (FOR CONVECTION-OVEN MODELS ONLY)  
Wiring diagrams are located on the rear of the range. Be sure that the input voltage and phase match the  
requirements shown on the serial plate (see Figure 1 on page 3).  
Ranges are factory-equipped either with a power cord or with one or two two-pole terminal blocks (one for each oven),  
located behind cover plate(s) located on the rear of the range. To connect the supply wires, remove the appropriate  
cover plate. Route the supply wires and the grounding wire through the strain relief fitting to the terminal block. Insert  
the supply wires, one each, into the two poles of the terminal block and tighten the screws. Insert the ground wire into  
the grounding lug and tighten the screw. Re-attach the cover plate.  
Three phase ranges are wired as above, using only two supply wires. The third wire is not used and must be properly  
terminated.  
All ranges are shipped wired as specified by factory order. Conversion between single-phase and three-phase can be  
accomplished by referring to phase loading and line amperes chart on wiring diagram for wire size and ampere  
requirements.  
STEP 5: GAS CONNECTION  
If this equipment is being installed at over 610 meters altitude and that information was not specified when ordered,  
contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure  
to install with proper orifice sizing will result in poor performance and may void the warranty.  
The serial plate is located on the interior side of the kick panel below the oven. It indicates the type of gas the range is  
equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 17 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
500 SERIES RESTAURANT RANGES  
These models are design-certified for operation on natural or propane gases. For natural gas, the regulator is set to  
deliver gas at 0.99 kPa (4" W.C.) pressure to the manifold. For propane gas, it is set to 2.48 kPa (10" W.C.).  
This appliance should be connected ONLY to the type of gas for which it is equipped.  
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for  
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems  
and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold  
pressure.  
The gas supply line to the range should be no smaller than the inside diameter of the pipes to which it is connected.  
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the range.  
CAUTION  
ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY  
SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS  
LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE RANGE HAS BEEN PUT INTO  
OPERATION. TEST PRESSURE SHOULD NOT EXCEED 14" W.C. (3.47 kPa).  
STEP 6: CHECK THE INSTALLATION  
Check the installation of the range, as follows:  
1. Check that all screws and bolts are tightened.  
2. Check that the electrical and gas connections have been made correctly.  
3. With the range in the position that it will be operated, check that the range is level. If not, adjust the legs or  
casters.  
4. Check that the appropriate minimum clearances are satisfied (see page 4).  
5. Check that the oven door(s) open and close properly.  
6. Check that there is sufficient clearance in front of the range to open the oven door.  
7. Wipe clean all surfaces.  
STEP 7: CHECK OPERATION  
Check the operation of the range, as follows:  
1. Turn on the gas supply and, for convection-oven models, the electric power supply.  
2. Light the burner pilots and oven pilot(s), starting with the top burner farthest from the gas input in order to  
purge the system of air. Check for proper pilot-flame height and adjust pilots, if necessary.  
3. Turn on the oven and all burners at the same time. Check for correct burner operation and adjust the air  
shutters, if necessary.  
4. On convection-oven models, turn on the blower(s) and check for proper operation.  
5. Turn off the burners and oven.  
STEP 8: SHUT-DOWN AND WIPE-CLEAN RANGE  
Complete the installation by leaving the range ready for customer use:  
1. Allow the range to cool.  
2. Wipe clean all surfaces.  
3. Unless the range is to be placed in service immediately, turn off the gas supply and (for convection-oven  
models, the electricity supply.  
4. Make sure that a copy of this manual will be available to the people who will operate and maintain the range.  
PAGE 18 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
SERVICE  
SERVICE  
WARNING  
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS  
EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING  
EQUIPMENT. TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR  
RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY  
PARTS.  
NOTICE  
INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS  
EQUIPMENT.  
The serial plate are located on the right side of the range (see Figure 1 on page 3).  
Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized  
Parts Distributor or a Southbend Authorized Service Agency.  
When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.  
In case of problems in operation at initial installation, check type of gas and manifold pressure and compare with  
information listed on the serial plate.  
This section contains troubleshooting flowcharts, procedures, and electric schematics to assist a qualified service  
technician in the servicing of a Southbend Model S500 Restaurant Range.  
TROUBLESHOOTING FLOWCHARTS, PROCEDURES, AND WIRING DIAGRAMS  
Find the symptom below that corresponds to the malfunction, then turn to the corresponding page. Follow the  
flowchart on that page until the problem is solved.  
Troubleshooting Flowchart, Procedure, or Wiring Diagram  
Page  
Troubleshooting Open-Top Burners  
Troubleshooting Base Oven  
Troubleshooting Convection-Oven Blower  
Adjustment of Gas Pressure Regulator  
Adjustment of Open-Top Pilots  
Adjustment of Open-Top Burners  
Adjustment of Oven Standing Pilot  
Adjustment of Oven Burner  
Adjustment of Oven Bypass Flame Level  
Calibration of Oven Thermostat  
Conversion from One Type of Gas to Another  
Wiring Diagram for 115 Volt Models  
Wiring Diagram for 208-230 Volt Models  
OWNERS MANUAL 1188716 (02/07)  
PAGE 19 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVICE  
500 SERIES RESTAURANT RANGES  
TROUBLESHOOTING OPEN-TOP BURNERS  
Each open-top burner should have a steady blue flame on each port of the burner. Propane burners may have a small  
amount of yellow tipping, and may make a slight popping noise when turned off.  
If the flame is rising up off of the ports, adjust the burner shutter so it is more closed. If the flame is long and yellow  
adjust the burner shutter so it is more open.  
Consult the following table and the flowchart on this page.  
Problem  
Look for -  
No burners or pilots in the range will turn on.  
All burners produce excessive carbon deposits.  
– Main gas supply to range is OFF.  
– Incorrect gas type supplied to range.  
– Incorrect supply pressure.  
Only some burners in a range produce excessive carbon  
deposits.  
– Incorrect orifices.  
– Primary air not adjusted properly.  
Only some pilots produce excessive carbon deposits.  
Top burner will not come on, but oven will come on.  
Open-top burner pilot will not stay ignited.  
– Pilot gas not adjusted properly.  
– Incorrect pilot orifice.  
– Control valve for top burner is in OFF position.  
– Pilot out.  
– Pilot gas not adjusted properly.  
– Clogged orifice.  
– Draft condition.  
– Improper ventilation system.  
– Air in gas line.  
– Thermocouple bad.  
Figure 8  
Troubleshooting Open-Top Burners  
Open-top burners are not working correctly.  
Check that the burners are set level in their support brackets.  
Check that the burners are clean and that their ports are clear.  
Remove each burner and check that the venturi is clean and free of  
buildup and debris. Also check that the orifice size is correct and  
that it is clean and free of buildup and debris.  
Remove the burner control knobs and carefully lower the valve  
panel. CAUTION! Convection oven models have wiring attached  
behind the panel.  
Check that each burner valve and orifice is in alignment with the  
corresponding burner.  
Check the pressure of the gas supply with all the gas appliances  
connected to the supply turned fully on. The inlet pressure (before  
entering the pressure regulator for the range) must be in the range  
3.5" to 5" W.C. (0.87 to 1.24 kPa) for natural gas, or in the range  
10" to 11" W.C. (2.48 to 2.73 kPa) for propane. Adjust the pressure  
and/or capacity of the gas supply, if necessary.  
Check the pressure of the gas manifold of the range (after the gas  
leaves the pressure regulator for the range). See page 25.  
PAGE 20 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
TROUBLESHOOTING BASE OVEN  
CAUTION  
Proper and efficient operation of oven is dependent on correct installation and function of components. Always  
verify that components are in place and functioning as intended.  
Consult the following table and the flowchart that begins on the following page.  
Problem  
Look for -  
Oven will not come on.  
Oven pilot will not stay ignited  
– Oven pilot is out.  
– Pilot gas not adjusted properly.  
– Bad thermocouple.  
– Bad thermocouple connections at safety valve.  
– Bad safety.  
– Clogged orifice.  
– Draft condition.  
– Improper ventilation system.  
– Air in gas line.  
Figure 9  
Troubleshooting Oven Pilot  
Oven pilot does not work.  
Check whether the pilot flame is lit by looking through the hole in  
the bottom of the oven. Leave the oven door open for five minutes  
to allow gas fumes to clear.  
If the pilot is not lit, attempt to light the pilot by raising the kick panel  
slightly and rotating its top edge outward. Press and hold the red  
button on the oven safety valve and put a flame to the pilot.  
Does the pilot light?  
No  
Yes  
Check that the oven pilot adjustment on the manifold is open.  
Continue to hold the red button for 30 seconds. The pilot should  
remain lit after the button is released. If it does not, wait five  
minutes and try again.  
If the pilot still will not light, do the following: Remove the oven  
bottom. Loosen the pilot nut on the burner bracket. Remove the  
pilot tube from the safety valve. Remove the pilot orifice from the  
pilot or end of the tube and check for debris.  
If the pilot will not remain lit, do the following: Remove the  
thermocouple from the safety valve. Install a thermocouple adapter  
between the safety valve and the thermocouple to measure the  
direct-current millivoltage produced by the thermocouple. While  
holding the red button, light the pilot and measure the voltage  
produced by the thermocouple. If the voltage does not rise above  
10 millivolts, adjust the pilot valve and retest. If the voltage still does  
not quickly rise above 10 millivolts, replace the thermocouple.  
If instead the thermocouple is working properly, replace the safety  
valve.  
Re-install the pilot orifice and tubing.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 21 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVICE  
500 SERIES RESTAURANT RANGES  
TROUBLESHOOTING CONVECTION-OVEN BLOWER  
WARNING  
Before attempting to service or replace any electrical component, make sure power source has been  
disconnected.  
CAUTION  
When changing motor or servicing range, always verify that blower wheel rotation is clockwise when looking into  
the oven cavity.  
The motor is serviceable from the front of the range through the oven cavity. Remove the back lining. Disconnect the  
motor mount plate by removing the eight hex nuts that secure it to the oven interior back. Pull the mount plate, with  
motor attached, into the oven.  
Motor lubrication information can be found on permanent label located on motor.  
If the blower does not run at all, consult the flowchart that begins on the next page. If the blower runs intermittently,  
consult the flowchart on this page.  
The appropriate wiring diagram for the oven can be found on the rear of the oven (as well as at the end of this section  
of this manual).  
Figure 10  
Convection-Oven Blower Runs Intermittently  
Convection-oven blower runs intermittently.  
Does the problem  
occur only when the oven  
is hot?  
No  
Yes  
DISCONNECT POWER AT CIRCUIT BREAKER.  
Check that there are no air-flow obstructions around the range.  
Check all wiring for loose connections or breaks.  
Check that the blower motor is not pressing against the wall  
behind the range.  
Remove the cover from the junction box on the back of the range.  
Disconnect the black wire and place an ammeter in the circuit.  
CAUTION: Check that the ammeter is rated for at least 40  
amperes! Reconnect the power to the range and turn on the  
blower switch while watching the ammeter. The reading should  
surge and then return to the rated current of the motor when  
running at high speed. If the measured current exceeds the motor  
rating, replace the blower motor.  
Check that the blower motor air vents are not obstructed.  
Check for excessive grease and dust buildup on the motor.  
Check for sources of excessive heat behind the range.  
Check for hot-air leaks around the motor pocket.  
With the blower turned ON, turn the oven thermostat to OFF and  
allow the oven to cool. If the blower motor runs continuously  
when the oven is cool, turn the oven thermostat to the highest  
setting. If the blower motor shuts off when the oven becomes hot,  
and if there are no sources of excessive heat around the blower  
motor, replace the blower motor.  
PAGE 22 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 11  
Convection-Oven Blower Does Not Run  
Convection-oven blower does not run.  
DISCONNECT POWER AT CIRCUIT BREAKER.  
Remove the control knobs from the front of the range. Remove the  
screws that secure the top of the valve panel and carefully tilt the  
panel forward to expose the back of the blower switch that is  
mounted in the front panel. CAUTION: Be careful not to damage  
the wiring behind the control panel. Remove the protective cover  
from the blower control switch.  
Check that the switch wires and terminals are secure.  
Use a multimeter to check the continuity across the terminals of  
blower-switch wires 1 and 3 (refer to the appropriate wiring diagram  
in this manual or on the range). With the switch in the ON position,  
there should be continuity.  
Is there continuity?  
No  
Yes  
Replace the blower control switch.  
Reconnect the power supply. Use a voltmeter to measure the  
voltage across the center terminals of switch wires 1 and 2.  
Does the measured  
voltage match the rated voltage  
of the range?  
Yes  
No  
Re-assemble the switch cover and valve panel. Turn on the blower-  
control switch and open the oven door.  
Check power supply to range.  
Does the blower  
run with the oven door  
open?  
No  
Yes  
DISCONNECT POWER AT CIRCUIT BREAKER.  
DISCONNECT POWER AT CIRCUIT BREAKER.  
Open the kick panel below the oven door by raising it slightly and  
tilting the top edge outward. Locate the door switch and check for  
continuity across the wired switch terminals while pressing the  
switch actuator lever.  
Open the kick panel below the oven door by raising it slightly and  
tilting the top edge outward. Locate the door switch and check that  
one wire is connected to the common (90° bottom) terminal of the  
switch. Move the other wire to the normally open (lower leg)  
terminal on the side of the door switch.  
Is there continuity?  
No  
Yes  
Replace door switch.  
Close the oven door (which should  
press the door-switch actuator lever).  
Is there continuity?  
Continue on next page.  
No  
Yes  
Loosen the two screws on the door switch bracket and adjust it so  
that the door switch is pressed when the oven door is closed.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 23 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE  
Figure 12  
500 SERIES RESTAURANT RANGES  
Convection-Oven Blower Does Not Run, Continued  
(Continuing from previous page.)  
CHECK THAT POWER IS DISCONNECTED  
AT CIRCUIT BREAKER.  
Remove the wire terminal cover from the blower motor.  
Check that the red wire is capped off.  
Remove the wire nuts from the black and the white wires. Check  
that in each case the wires are twisted together securely.  
Check that the common wire is connected to the motor black wire.  
Check that the neutral wire is connected to the white wire.  
Reconnect the power supply and turn on blower-control switch.  
Use a voltmeter to measure the voltage between the black wire and  
the white wire.  
Is there voltage?  
No  
Yes  
DISCONNECT POWER AT CIRCUIT BREAKER.  
DISCONNECT POWER AT CIRCUIT BREAKER.  
Check all wiring for loose terminals or breaks.  
Remove the wire nuts from the red, white, and black wires.  
Check that the resistance across the white and black wires is  
approximately 1.9 ohms. Check that the resistance across the  
white and red wires is also approximately 1.9 ohms. If either  
resistance is incorrect, replace the blower motor.  
ADJUSTMENT OF GAS PRESSURE REGULATOR  
The pressure regulator is factory set at 4" W.C. (0.99 kPa) for natural gas and 10" W.C. (2.48 kPa) for propane gas.  
To check the manifold pressure:  
1. Turn all thermostats and burner valves to OFF position.  
2. Turn main gas valve to entire range off.  
3. Remove valve panels and locate the small plug in the manifold.  
4. Remove plug and install a fitting appropriate to connect a manometer.  
5. Turn on main gas to range and light pilots.  
6. Turn all burners and ovens to full ON position and read manometer.  
7. If manometer does not read 4" W.C. (0.99 kPa) for natural gas, or 10" W.C. (2.48 kPa) for propane gas, adjust  
regulator (if gas pressure is correct go to Step 10).  
8. Remove cap from top of regulator.  
9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to decrease,  
pressure until manometer shows correct reading.  
10. Repeat steps 1 and 2.  
11. Remove manometer fitting and replace plug in manifold.  
12. Turn on main gas to range and light pilots.  
13. Replace valve panels.  
PAGE 24 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
ADJUSTMENT OF OPEN-TOP PILOTS  
The open-top pilots are the non-aerated (yellow-tipped flame) type. One is located beside each open-top burner.  
Pilot outage is often caused by an unstable flame due to over-adjustment to the point where the flame is leaving its  
port, or “blowing off.” Often, in an effort to improve ignition, the pilots are increased too much and result in this  
unstable condition.  
The pilots are adjusted by inserting the blade of a screwdriver into the slot on the small valve, located on the manifold.  
The maximum flame size is approximately 19 mm with a slight yellow tip. The first indication of over-adjustment is  
evident when the yellow tip begins to stream into black streaks and generate carbon. Continued over-adjustment  
leads to the unstable lifting and blowing condition.  
ADJUSTMENT OF OPEN-TOP BURNERS  
All open-top burners are primarily adjusted by means of an air shutter on the mixer face.  
To adjust a burner, loosen the screw that holds the air shutter in position and rotate the mixer cap until a clear, stable  
blue flame is obtained. The flame should not be yellow tipped nor should it blow off the burner ports.  
All orifice sizes and burner rate are properly set at the factory and should not be altered.  
Over-rated burners cause poor burner and pilot performance, resulting in less heat, and wasted gas.  
ADJUSTMENT OF OVEN STANDING PILOT  
The standing oven pilot flame can be adjusted by turning the adjusting screw on the pilot line valve with a screwdriver.  
The pilot line valve is located behind the kick panel below the oven door. Remove the kick panel to gain access. The  
pilot flame is properly adjusted when it is just large enough to maintain a glowing red color of the flame switch  
capillary bulb.  
ADJUSTMENT OF OVEN BURNER  
The oven burner orifice is of the fixed type, sized for the specified gas supply. The burner flame characteristics are  
controlled by varying the primary air mixer cap. There should be a clear blue flame with a distinct inner cone at each  
port. Excessive primary air can result in “blowing” or the flames leaving the ports. Lack of primary air causes soft or  
yellow tipped flame.  
ADJUSTMENT OF OVEN BYPASS FLAME LEVEL  
When the oven reaches the temperature at which the dial is set, the oven thermostat reduces the flow of gas to the  
amount required to keep the oven at that temperature. However, the thermostat must always supply enough gas to  
keep the entire burner lighted. To maintain this minimum flame, the bypass must be set carefully and accurately using  
the following procedure (see illustration on page 27):  
1. Open the kick panel below the door of the oven by lifting it slightly and pulling the top edge away from the  
oven. The oven burner should now be visible.  
2. Turn the oven thermostat to its highest setting and check that the oven burner ignites.  
3. After 5 minutes, turn the oven thermostat down to point between the two lines on the thermostat dial between  
OFF and the lowest temperature setting (this is the bypass setting).  
4. Check to see if the flame is about 1/4 inch (6 mm) high along the entire length of the burner. If it is, the bypass  
flame level does not need adjustment. If it is not, continue with this procedure.  
5. Remove the control knobs, thermostat dial and bezel, and the valve panel.  
6. Using a screwdriver, turn the bypass adjustor on the stem of the thermostat (see illustration on page 27)  
counterclockwise to increase the flame or clockwise to decrease the flame until the flame is approximately 6  
mm (1/4 inch) high along the entire length of the burner. (If no flame is present at all, place a flame at the  
burner shutter to check for gas flow.) If the proper flame level cannot be established, replace the thermostat.  
7. Replace the valve panel, control knobs, and thermostat bezel and dial. Turn all control knobs to the OFF  
position.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 25 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVICE  
500 SERIES RESTAURANT RANGES  
CALIBRATION OF OVEN THERMOSTAT  
The oven thermostat control is carefully calibrated at the factory so that its dial settings closely match actual oven  
temperatures. Field recalibration is seldom necessary, and should not be resorted to unless considerable experience  
with unexpected cooking results definitely proves that the control is not maintaining the temperatures to which the dial  
is set.  
Do not recalibrate the oven thermostat until after the oven bypass flame has been adjusted (see previous procedure).  
When checking the oven temperature, use a test instrument or a reliable mercury thermometer positioned in the  
center of the oven. The oven bottom must be in place. For convection ovens, the blower baffle must be in place.  
Proceed as follows:  
1. Place the thermometer or the thermocouple of the test instrument on an oven rack in the center of the oven.  
2. Remove the thermostat knob and push out its metal insert (see Figure 13 on page 27).  
3. Replace the thermostat knob and turn it to the 400°F (200°C) mark. Check that the oven burner comes on.  
4. After oven burner has been on about 15 minutes, check the oven temperature. Open the oven door for as  
short a time as possible. Use a flashlight, if necessary, to see the thermometer or test instrument clearly.  
5. Continue to check the temperature at five-minute intervals until two successive readings are within 5°F (3°C)  
of each other. If successive readings continue to vary too much, first check the bypass-flame level. If the  
temperature still will not stabilize, replace the oven thermostat.  
6. If the stable, measured oven temperature is in the range 390°F to 410°F (194°C to 226°C) it is not necessary  
to change the thermostat calibration. If it is outside of the temperature range, continue with this procedure.  
7. Look into the thermostat knob to see the calibration screw in the stem (see illustration on page 27). Arrows  
near the screw indicate which way to turn the screw to make the oven temperature higher or lower. If  
necessary, scrape the paint seal off the screw. While holding the thermostat knob firmly to prevent the stem  
from turning, insert a screwdriver through center of the knob, push the calibration screw inward, and turn the  
screw in the appropriate direction that will increase or decrease the oven temperature to make the measured  
temperature agree with the dial setting. Turn the screw only in small increments until the stable, measured  
oven temperature is in the range 390°F to 410°F (194°C to 226°C).  
8. Turn the thermostat knob to the 450°F (230°C) mark. Allow the oven to heat until two successive readings  
made five minutes apart are within 5°F (3°C) of each other. If the stable, measured oven temperature is now in  
the range 440°F to 460°F (224°C to 236°C) it is not necessary to further adjust change the thermostat  
calibration. If the oven temperature cannot be set correctly, replace the thermostat.  
9. Replace the knob insert that was removed in Step 2.  
PAGE 26 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 13  
Thermostat Calibration and Bypass Flame Adjustment  
Bypass Adjuster  
Calibration Stem  
Bezel  
Dial Insert  
Dial  
CONVERSION FROM ONE TYPE OF GAS TO ANOTHER  
Each range is shipped adjusted and equipped for a specific type of gas (either natural gas or propane). To convert a  
range from one type of gas to another, do the following:  
1. Refer to service procedures to access all burner orifices.  
2. Refer to instructions included with conversion kit.  
3. Follow all steps as indicated in the conversion kit.  
4. Check for leaks and proper manifold pressure (the procedure is on page 24).  
5. Re-light all pilots and check for proper operation.  
Note: A kit for conversion to a different type of gas may be purchased from Southbend.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 27 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVICE  
Figure 14  
500 SERIES RESTAURANT RANGES  
Wiring Diagram for 115 Volt Models  
PAGE 28 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 15  
Wiring Diagram for 208-230 Volt Models  
OWNERS MANUAL 1188716 (02/07)  
PAGE 29 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVICE  
500 SERIES RESTAURANT RANGES  
PARTS  
NOTICE  
INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS  
EQUIPMENT.  
The following parts diagrams list and show serviceable parts. For parts not listed, contact a Southbend Authorized  
Parts Distributor or a Southbend Authorized Service Agency.  
Parts Diagram  
Page  
Leg and Caster Parts  
External Panel and Drip Pan Parts  
Flue Riser and Shelf Parts  
Open-Top Burner Parts for X500 Models  
Open-Top Burner Parts for S500 Models  
Piezo Spark Module Parts  
Convection Oven Parts  
Standard Oven Parts  
Electric Gas Shut-Off Parts (for S500 Units Built Before February 19, 2007)  
Figure 16  
Leg and Caster Parts  
3
2
1
4
5
Key Part Number Qty Description  
1/4 X 20 X 3/4 HEX HEAD  
1
2
3
4
*
1146201  
1146500  
1172650  
1178205  
1174262  
16  
16  
4
1/4 LOCK WASHER  
LEG PAD (3/4 X 10 HOLE)  
LEG PACKAGE (SET OF 4 LEGS, NOT INCLUDING BOLTS, LEG PADS, OR LOCK WASHERS)  
EARTHQUAKE LEGS SS (SET OF 4)  
1
1
CASTER PACKAGE (TWO CASTERS WITH BRAKE AND TWO WITHOUT BRAKE; DOES NOT INCLUDE BOLTS, LOCK WASHERS, OR  
LEG PADS)  
5
1174265  
1
*
Not shown on drawing.  
PAGE 30 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 17  
External Panel and Drip Pan Parts  
1
2
3
3
Key  
1
Part Number  
1180744  
1180743  
1188243  
Qty Description  
SIDE PANEL, LEFT  
SIDE PANEL, RIGHT  
1
1
*
2
KICK PANEL FOR FULL SIZE OVENS (A AND D SERIES)  
DRIP PAN, 24", SS  
3
** 1188605  
1188604  
*
DRIP PAN, 36", SS  
*
*
Quantity used depends on model number.  
** Not shown on drawing.  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 31 OF 44  
 
SERVICE  
Figure 18  
500 SERIES RESTAURANT RANGES  
Flue Riser and Shelf Parts  
1
2
3
Key  
1
Part Number  
1188669  
1188670  
1181158  
1184141  
1181160  
1184143  
1181162  
1180763  
1181164  
1180765  
Qty Description  
SHELF SINGLE ASM, 36" TRAY  
1
1
1
1
1
1
1
1
1
1
SHELF SINGLE ASM, 60" TRAY  
SPLASHER, 10" X 36"  
2
SPLASHER, 24" X 36"  
SPLASHER, 10" X 60"  
SPLASHER, 24" X 60"  
WALL SHIELD, 10" X 36"  
WALL SHIELD, 22.5" X 36"  
WALL SHIELD, 10" X 60"  
WALL SHIELD, 22.5" X 60"  
3
PAGE 32 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 19  
Open-Top Burner Parts for X500 Models  
5
3
13  
12  
10  
7
8
11  
6
9
5
4
3
15  
2
1
14  
Quantity*  
Key Part Number  
Description  
X536 X560  
KNOB, CHROME METAL  
GAS VALVE, HI-OFF  
1
2
3
1184192  
1178202  
1008742  
1009754  
1177447  
1177111  
1177448  
1184626  
1184744  
P6016  
6
6
6
6
3
6
3
3
3
3
3
3
3
3
3
3
3
3
3
10  
10  
10  
10  
5
HOOD, ORIFICE #42 (NATURAL GAS)  
HOOD, ORIFICE #54 (LP GAS)  
PILOT ASSEMBLY, FRONT  
BURNER ASSEMBLY  
4
5
6
7
8
9
10  
5
PILOT ASSEMBLY, REAR  
PILOLT SUPPORT BRACKET  
SPACER  
5
5
FITTING, BRASS, STRT, 68C-6-4  
TUBE, REAR BURNER  
5
10 1182286  
11 1148306  
12 1182287  
** 1166004  
13 1148301  
14 1180781  
1187488  
5
FITTING, ORIFICE BODY  
BRACKET, REAR TUBE SUPPORT  
5
5
DOUBLE PILOT ADJUSTMENT FITTING  
NUT, BRASS JAM  
5
5
FRONT GRATE  
5
FRONT GRATE, WAVY  
REAR GRATE  
5
15 1180405  
1187489  
5
REAR GRATE, WAVY  
5
*
Quantity used depends on model number.  
** Not shown.  
OWNERS MANUAL 1188716 (02/07)  
PAGE 33 OF 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVICE  
Figure 20  
500 SERIES RESTAURANT RANGES  
Open-Top Burner Parts for S500 Models  
13  
14  
12  
15  
9
8
7
6
11  
5
4
3
17  
2
16  
10  
1
Quantity*  
Key Part Number  
Description  
S536 S560  
KNOB, CHROME METAL  
1
2
3
4
5
6
7
8
1184192  
1182482  
P6016  
6
6
3
3
3
3
3
6
6
6
3
3
6
3
6
6
3
3
10  
10  
5
VALVE, CE OPEN TOP BURNER  
FITTING, BRASS, STRT, 68C-6-4  
TUBE, CE REAR BURNER  
FITTING, ORIFICE BODY  
1182487  
1148306  
1182287  
1148301  
1008737  
1008754  
1177111  
5
5
BRACKET, REAR TUBE SUPPORT  
NUT, BRASS JAM  
5
5
HOOD, ORIFICE #37 (NATURAL GAS)  
HOOD, ORIFICE #54 (LP GAS)  
BURNER ASSEMBLY  
10  
10  
10  
5
9
TUBE, CE FRONT PILOT  
TUBE, CE REAR PILOT  
PILOT, CE  
10 1182489  
11 1182490  
12 1182485  
13 1182488  
14 1182494  
15 1182486  
16 1187488  
17 1187489  
5
10  
5
BRACKET, CE PILOT SUPPORT  
SHIELD, CE PILOT  
10  
10  
5
THERMOCOUPLE, CE  
FRONT GRATE, WAVY  
REAR GRATE, WAVY  
5
*
Quantity used depends on model number.  
PAGE 34 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 21  
Piezo Spark Module Parts  
7
8
3
5
6
4
2
1
Quantity*  
Key Part Number  
Description  
X536 X560  
SWITCH, PB, SPARK  
WIRE, SWITCH  
1
2
3
4
5
6
7
1182704  
1182710  
1182706  
1186453  
1186455  
1182705  
1186452  
1186454  
3
3
3
3
3
3
3
3
5
5
5
5
5
5
5
5
MODULE, SPARK  
BRACKET, SPARK MODULE  
HOLDER, BATTERY 9V PIEZO  
BATTERY, 9V  
BRACKET, PIEZO ELECTRODE  
ELECTRODE, SPARK MODULE  
8
*
Quantity used depends on model number.  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 35 OF 44  
 
SERVICE  
500 SERIES RESTAURANT RANGES  
Convection Oven Parts  
See drawing on following page.  
Key  
1
Part Number Qty* Description  
PANEL, KICK  
1188243  
1180861  
1188714  
1184226  
1
2
1
1
1
8
2
1
1
4
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
DOOR HINGE  
2
DOOR ASSEMBLY (FULL OVEN)  
DOOR HANDLE (FULL OVEN)  
SPRING, DOOR (FULL OVEN)  
CLIP, RACK SUPPORT  
RACK GUIDE  
3
4
** P1089  
5
6
7
8
9
6660  
1180528  
1177581  
1180821  
1179710  
BLOWER WHEEL ASSEMBLY  
POCKET WELD ASSEMBLY  
SPACER, BLOWER  
MOTOR, 1/3 HP, 208/240 VOLT  
MOTOR, 1/3 HP, 115VOLT  
BRACKET, DOOR SWITCH  
SWITCH, DOOR  
10 1179688  
1188523  
11 1181117  
12 1177567  
13 1180859  
14 1188707  
15 1180841  
16 1188712  
17 1164278  
1164279  
QUADRANT ASSEMBLY  
OVEN BAFFLE CO  
BRACKET, OVEN BAFFLE  
OVEN BOTTOM (FULL OVEN)  
SA BURNER (NATURAL GAS)  
SA BURNER (LP GAS)  
OVEN SAFETY VALVE  
18 1164037  
19 1008736  
1008752  
HOOD ORIFICE #36 (NATURAL GAS)  
HOOD ORIFICE #52 (LP GAS)  
PILOT TUBE  
20 1180873  
21 1163868  
22 1180830  
23 1182498  
24 1182497  
25 B940000201  
THERMOCOUPLE  
BRACKET, OVEN SAFETY  
KNOB, OVEN THERMOSTAT DIAL, FAHREINHEIT  
BEZEL, OVEN THERMOSTAT KNOB  
THERMOSTAT  
*
Quantity per oven.  
** Not shown on drawing.  
PAGE 36 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 22  
Convection Oven Parts  
See parts list on previous page.  
13  
12  
11  
10  
9
8
7
14  
6
15  
5
4
17  
3
2
16  
1
25  
24  
23  
18  
19  
20  
22  
21  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 37 OF 44  
SERVICE  
500 SERIES RESTAURANT RANGES  
Standard Oven Parts  
See drawing on following page.  
Key  
1
Part Number  
1188243  
1180861  
P1089  
Qty Description  
DOOR ASSEMBLY (FULL OVEN)  
1
2
1
1
2
8
1
1
1
1
1
1
1
1
1
1
1
1
1
DOOR HINGE  
2
SPRING, DOOR (FULL OVEN)  
OVEN BOTTOM (FULL OVEN)  
RACK GUIDE  
*
3
1188714  
1180528  
6660  
4
CLIP, RACK SUPPORT  
*
QUADRANT ASSEMBLY  
SA BURNER (NATURAL GAS)  
SA BURNER (LP GAS)  
5
1180859  
1164278  
1164279  
1182498  
1182497  
B940000201  
1182493  
6
KNOB, OVEN THERMOSTAT DIAL, FAHREINHEIT  
BEZEL, OVEN THERMOSTAT KNOB  
THERMOSTAT  
7
8
9
*
SHIELD, CE THERMOSTAT  
OVEN SAFETY VALVE  
10 1164037  
HOOD ORIFICE #36 (NATURAL GAS)  
HOOD ORIFICE #52 (LP GAS)  
PILOT TUBE  
11 1008736  
1008752  
12 1180873  
13 1163868  
14 1180830  
THERMOCOUPLE  
BRACKET, OVEN SAFETY  
*
Not shown on drawing.  
PAGE 38 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
SERVICE  
Figure 23  
Standard Oven Parts  
See parts list on previous page.  
9
8
7
5
4
6
3
10  
11  
1
12  
2
13  
14  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 39 OF 44  
SERVICE  
Figure 24  
500 SERIES RESTAURANT RANGES  
Electric Gas Shut-Off Parts (for S500 Units Built Before February 19, 2007)  
1
3
2
5
8
7
4
6
Key  
1
2
3
*
Part Number  
1181066  
1186427  
1179908  
1181067  
1181062  
1181063  
1180402  
1172760  
1179947  
1181061  
1146801  
Qty Description  
SWITCH, OFF/ON/ON-MOMENTARY  
1
1
1
1
1
1
1
1
1
1
1
1
VALVE PANEL, 460, SS SHUTOFF  
BRACKET, FAN SWITCH  
CAFE SHUTOFF HARNESS ASSEMBLY  
BOX, 4" SQ. ELEC. JUNCTION  
COVER, ELEC. JUNCTION BOX  
RELAY, 120  
4
5
*
CO POWER CORD  
*
FLEX CABLE, 17"  
*
VALVE, GAS SHUTOFF  
NIPPLE, PIPE  
6
7
REGULATOR, PRESSURE  
8
1178815  
*
Not shown on drawing.  
PAGE 40 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
500 SERIES RESTAURANT RANGES  
Notes:  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 41 OF 44  
500 SERIES RESTAURANT RANGES  
Notes:  
PAGE 42 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 SERIES RESTAURANT RANGES  
Notes:  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 43 OF 44  
500 SERIES RESTAURANT RANGES  
500 Series  
RESTAURANT RANGES  
A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize,  
however, that replacement parts and occasional professional service may be necessary to extend the useful life of  
this appliance. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid  
confusion, always refer to the model number, serial number, and type of your appliance.  
Southbend  
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526  
PAGE 44 OF 44  
OWNERS MANUAL 1188716 (02/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shark Vacuum Cleaner EP602RF User Manual
Shure TV Antenna UAPF X1 User Manual
Snapper Chipper 5 14 SERIES User Manual
Snapper Trimmer 1685203 User Manual
Sony Camera Lens SAL24F20Z User Manual
Sony Home Theater System Model HTR 6100 User Manual
Sony Tablet Accessory VGP BMS33 User Manual
SOYO Computer Hardware 266 User Manual
Sterling Plumbing Outdoor Shower 71090115 User Manual
Sylvania CRT Television 6413CTC 6419CTC User Manual