Sony Webcam SXV M5C User Manual

Handbook for SXV-M5C  
Issue 1 August 2004  
Starlight Xpress Ltd  
SXV-M5C  
CCD camera user manual  
Thank you for purchasing a Starlight Xpress CCD camera. We hope that you will be  
very satisfied with the results. The SXV-M5C is a medium-resolution cooled CCD  
camera, especially designed for colour astronomical imaging. The SXV-M5C uses a  
Sony SuperHAD CCD, with 500 x 582 pixels in a 4.9mm x 3.65mm active area.  
SuperHAD devices have the greatest quantum efficiency of any interline transfer  
CCD currently available and the use of high performance microlenses on the CCD  
surface gives the greatest possible throughput of light to the pixels. This camera is a  
next generation version of the parallel port driven MX5C, but the use of an internal  
USB2 interface and the addition of an external guide camera option makes it  
considerably more effective.  
Please take a few minutes to study the contents of this manual, which will help you to  
get the camera into operation quickly and without problems. I am sure that you want  
to see some results as soon as possible, so please move on to the ‘Quick Start’ section,  
which follows. A more detailed description of imaging techniques will be found in a  
later part of this manual.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
Connect the miniature 4 way power plug to the socket on the rear of the camera and  
screw the retaining ring into place. The LED on the rear of the camera will light a dim  
yellow. The other connections should not be attached until after the software has been  
installed.  
Installing the software:  
Switch on the computer and allow it to ‘boot up’. Once you have the system ready to  
run, insert the program disk into your CD drive and select ‘Setup.exe’ if the disk does  
not autostart. The initial installation is to set up the USB drivers required by the SXV  
electronics. The files SXVIO.sys and Generic.sys are copied to your  
Windows\System32\Drivers folder and SXV_M5.inf is copied to Windows\Inf.  
After this, the program ‘SXV_M5.exe’ will be installed into your ‘CCD’ directory  
and a new directory called ‘Autosave’ will now exist on the same drive. ‘Autosave’ is  
where SXV_M5 will normally store its configuration file, ‘SXVM5.ini’, and any  
image files, which are recorded using the ‘Autosave’ mode in SXV_M5 and saved in  
FITs format.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
You now need to set up the camera control defaults (shown above), as follows:  
Start SXV-M5C by clicking on the icon and select the ‘File’ menu. Now select ‘Set  
program defaults’ and a window, which contains the various software settings, will  
appear. Suggested starting defaults are as follows:  
1) Background Image area  
Red (or as preferred)  
2) Interlaced image smoothing  
3) FITS Unsigned Integer format  
On  
Off  
4) Star mask size (area used for photometry and guiding)  
8 pixels  
The other default settings are not important for current purposes and may be left as  
the software start-up values for now.  
Recording your first image:  
We now have the camera and computer set up to take pictures, but an optical system  
is needed to project an image onto the CCD surface. You could use your telescope,  
but this introduces additional complications, which are best avoided at this early  
stage. There are two simple options, one of which is available to everyone:  
1) Attach a standard ‘M42’ SLR camera lens to the SXV-M5C, using a 27mm spacer  
to achieve the correct focal distance. M42 thread spacers are available from most  
photographic stores, or from Starlight Xpress dealers.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
2) Create a ‘Pin hole’ lens by sticking a sheet of aluminium baking foil over the end  
of the 1.25” adaptor and pricking its centre with a small pin.  
If you use a normal lens, then stop it down to the smallest aperture number possible  
(usually F22) as this will minimise focus problems and keep the light level reasonable  
for daytime testing. The pin hole needs no such adjustments and will work  
immediately, although somewhat fuzzily.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
Point the camera + lens or pinhole towards a well-lit and clearly defined object some  
distance away. Now click on the camera icon in the toolbar of the SXV-M5C software  
and the camera control panel will appear (see above). Select an exposure time of 0.1  
seconds and press ‘Take photo’. After the exposure and download have completed  
(between 1 and 3 seconds) an image of some kind will appear on the computer  
monitor. It will probably be poorly focused and incorrectly exposed, but any sort of  
image is better than none! In the case of the pinhole, all that you can experiment with  
is the exposure time, but a camera lens can be adjusted for good focus and so you  
might want to try this to judge the image quality that it is possible to achieve.  
One potential problem with taking daylight images is the strong infrared response of  
the SXV-M5C and this will cause ‘soft focus’ with camera lenses. Soft focus with  
camera lenses is much reduced by keeping the aperture setting below F8. IR blocking  
filters are available from various suppliers (True Technology, Edmunds etc.) and are  
recommended for the best results.  
If you cannot record any kind of image, please check the following points:  
1) Is the power LED on?  
2) Does the software indicate that the camera is successfully connected? An attempt  
to take a picture will fail with an error message if the USB is not properly installed. In  
this case, try unplugging the USB cable and then reconnecting it after about 5  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
seconds. Restart the camera software and see if it can link now. If not, check in  
Windows device manager (via ‘System’ in ‘Control Panel’) and see if the BlockIO  
device is installed properly.  
3) If you cannot find any way of making the camera work, please try using it with  
another computer. This will confirm that the camera is OK, or otherwise, and you can  
then decide how to proceed. Also check on our web site to see if there are any updates  
or information about your camera software that might help. The message board might  
prove useful to ask for help with getting your camera operating properly.  
Our guarantee ensures that any electrical faults are corrected quickly and at no cost  
to the customer.  
Decoding the image to colour:  
Once you have a reasonably clear and well-exposed image, you might like to try  
generating a colour picture from it. The procedure is quite simple and may be carried  
out as follows:  
1) Check the ‘Set program defaults’ menu and ensure that the ‘Pixel’ and ‘Line’  
offsets are both unselected.  
2) Click on ‘Colour’ in the main menu and then select ‘Synthesise Colour Image’.  
3) Select ‘Apply Anti-Alias’, but leave the other options switched off.  
4) Click on ‘Create Image’.  
After a few seconds a recognisable colour image should be displayed, although the  
colour ‘balance’ may need correction. This is especially true if your image was taken  
indoors with artificial lighting, which can make everything look very orange.  
If the colour image shows white spots or patches, where no colour is present, then the  
original exposure time was too long and some pixels are overloaded. In this case, you  
need to take a new image with significantly less exposure time, or with the lens  
stopped down a little further.  
Correcting and refining the colour image:  
The colour balance of your image may be adjusted by selecting ‘Colour’, followed by  
‘Set Colour Balance’.  
You are presented with three histograms, which represent the Red, Green and Blue  
content of your image, with limits, which can be adjusted by slider controls.  
A good quality colour image will present three, roughly similar; histograms, and any  
small colour bias may be seen as different offsets above zero and different widths of  
the main bulk of the histograms. Moving the lower limit setting of a histogram will  
adjust the overall colour bias of the picture, with the amount of the particular colour  
concerned being reduced by moving the limit in the positive (to the right) direction.  
The location of the pointer represents the new ‘zero’ of the histogram. For instance, if  
your image is a little too red, you can reduce this by setting the lower pointer on the  
red histogram to, say, 4, and then clicking on OK. Equally, you can increase the red  
content by reducing both the blue and green content.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
In some cases, there may be a difference in colour bias between the faintest and  
brightest objects. When this happens, first reduce the error of the faint detail, using  
the ‘START’ sliders, and then correct the bright objects by using the ‘MAX’ sliders.  
The ‘MAX’ slider allows you to vary the ‘slope’ of the transfer curve and so change  
the way that the balance alters from faint to bright detail.  
Other options in the ‘Colour’ menu are ‘Apply Anti-Alias’ and ‘Adjust  
Chrominance’. We have already used the Anti-Alias filter as an option during colour  
synthesis, but it will be helpful for you to know its purpose. Basically, the AA filter is  
designed to remove colour errors at sharp transitions of brightness. Because of the  
spatial characteristics of the grid of filters on the CCD, a sharp edge in the image will  
overlay certain filters, but miss adjacent ones. When the colour synthesiser equations  
process the data from this region, there will be an incorrect result when these pixels  
are processed and a line of abnormal colour will follow the transition edge. This is  
well seen in images of stars, which often take on a strong colour bias, quite different  
from the expected star colour. The AA filter scans the colour image data and searches  
for fine details with rapidly changing colours. Wherever these errors occur, the filter  
substitutes the equivalent and equal values of red, green and blue, thus changing the  
deviant colour into neutral grey. The result is a much smoother colour image, with  
clean transitions around stars and other fine details. The AA filter may be used as  
many times as is desired, but its additional effects will be very slight after about 3  
passes of the image.  
The ‘Adjust Chrominance’ option is not needed for most images, but can be useful for  
removing atmospheric dispersion from images of the planets. ‘Adjust Chrominance’  
permits you to move the red and blue frames with respect to the green frame and so  
compensate for the displacement of the colours caused by the atmosphere. To use the  
AC function, shift the red and blue images until the planetary disc has an evenly  
coloured periphery and any red and blue fringes disappear.  
Enhancing your image:  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
Your first image may now be reasonably good, but it is unlikely to be as clear and  
sharp as it could be. Improved focusing and exposure selection may correct these  
shortcomings, and you may like to try them before applying any image enhancement  
with the software. However, there will come a point when you say, “That’s the best  
that I can get” and you will want to experiment with various filters and contrast  
operations. In the case of daylight images, the processing options are many, but there  
are few that will improve the picture in a useful way.  
The most useful of these are the ‘Normal Contrast Stretch’ and the ‘High Pass Low  
Power’ filter. The high pass filter gives a moderate improvement in the image  
sharpness, and the effects of image processing. This can be very effective on daylight  
images. Too much high pass filtering results in dark borders around well-defined  
features and will increase the ‘noise’ in an image to unacceptable levels, but the ‘Low  
Power’ filter is close to optimum and gives a nicely sharpened picture, as above.  
The ‘Contrast’ routines are used to brighten (or dull) the image highlights and  
shadows. A ‘Normal’ stretch is a simple linear operation, where two pointers (the  
‘black’ and ‘white’ limits) can be set at either side of the image histogram and used to  
define new start and end points. The image data is then mathematically modified so  
that any pixels that are to the left of the ‘black’ pointer are set to black and any pixels  
to the right of the ‘white’ pointer are set to white. The pixels with values between the  
pointers are modified to fit the new brightness distribution. Try experimenting with  
the pointer positions until the image has a pleasing brightness and ‘crispness’.  
At this point, you will have a working knowledge of how to take and process an SXV-  
M5C image. It is time to move on to astronomical imaging, which has its own,  
unique, set of problems!  
*********************************************************************  
Astronomical Imaging with the SXV-M5C  
1) Getting the image onto the CCD:  
It is fairly easy to find the correct focus setting for the camera when using a standard  
SLR lens, but quite a different matter when the M7 is attached to a telescope! The  
problem is that most telescopes have a large range of focus adjustment and the CCD  
needs to be quite close to the correct position before you can discern details well  
enough to optimise the focus setting. An additional complication is the need to add  
various accessories between the camera and telescope in order that the image scale is  
suitable for the subject being imaged and (sometimes) to include a ‘flip mirror’ finder  
unit for visual object location.  
A simple, but invaluable device, is the ‘par-focal eyepiece’. This is an eyepiece in  
which the field stop is located at the same distance from the barrel end, as the CCD is  
from the camera barrel end.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
When the par-focal eyepiece is fitted into the telescope drawtube, you can adjust the  
focus until the view is sharply defined and the object of interest is close to the field  
centre. On removing the eyepiece and fitting the CCD camera, the CCD will be very  
close to the focal plane of the telescope and should record the stars etc. well enough  
for the focus to be trimmed to its optimum setting  
Several astronomical stores sell par-focal eyepieces, but you can also make your own  
with a minimum of materials and an unwanted Kellner or Plossl ocular.  
Just measure a distance of 22mm from the field stop of the eyepiece (equivalent to the  
CCD to adaptor flange distance of the camera) and make an extension tube to set the  
field stop at this distance from the drawtube end. Cut-down 35mm film cassette  
containers are a convenient diameter for making the spacer tube and may be split to  
adjust their diameter to fit the drawtube.  
Another popular solution to the ‘find and focus’ problem is the ‘flip mirror’ unit.  
These operate on a similar principle to the single lens reflex camera, where a hinged  
mirror can drop into the light path and reflect the image through 90 degrees into a  
viewing eyepiece.  
In this case, the camera and eyepiece are made par-focal with each other by locking  
up the mirror, focusing the camera on an easy object, such as a moderately bright star  
and then flipping the mirror down to view the same star with the eyepiece. Once the  
eyepiece has been locked into the correct position, you can use it to focus on the  
image by lowering the flip mirror and operating the telescope focus wheel until the  
image is sharp. When the mirror is raised, the image will fall onto the CCD surface  
and should be accurately in focus. Most flip mirror units allow several adjustments to  
be made, so that the image can be centred properly in the eyepiece and CCD fields,  
which are not necessarily coincident when you first buy your unit!  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
Opinions vary as to the utility of flip mirrors. They are a convenient way to find and  
focus, but they add quite a bit of extra length between the camera and telescope. This  
can be very inconvenient with Newtonians, and not a lot better with SCTs, especially  
if the assembly is somewhat flexible. They also make it difficult to use a focal reducer  
with your camera, as the rapidly converging light cone from a reducer cannot reach all  
the way through the flip mirror unit to the CCD surface. If you are using one of the  
popular F3.3 compressors for deep sky imaging, you will NOT be able to include a  
flip mirror unit in front of your camera and a par-focal eyepiece is your best option.  
Whichever device you use, it is necessary to set up a good optical match between your  
MX5C and the telescope. Most SCTs have a focal ratio of around F10, which is too  
high for most deep sky objects and too low for the planets! This problem is quite easy  
to overcome, if you have access to a telecompressor (for deep sky) and a Barlow lens  
for planetary work. The new Meade F3.3 compressor is very useful for CCD imaging  
and I can recommend it from personal experience. It does not require a yellow filter  
for aberration correction, unlike some other designs, so it can be used for colour  
imaging. Barlow lenses are less critical and most types can be used with good results.  
However, if you are buying one for CCD imaging, I recommend a 3x or 5x amplifier,  
or the planets will still be rather small in your images. As a guide, most CCD  
astronomers try to maintain an image scale of about 2 arc seconds per pixel for deep  
sky images. This matches the telescope resolution to the CCD resolution and avoids  
‘undersampling’ the image, which can result in square stars and other unwanted  
effects. To calculate the focal length required for this condition to exist, you can use  
the following simple equation:  
F = Pixel size * 205920 / Resolution (in arc seconds)  
In the case of the SXV-M5C and a 2 arc seconds per pixel resolution, we get  
F = 0.0096 * 205920 / 2  
11  
= 844mm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
For a 200mm SCT, this is an F ratio of 844 / 200 = F4.22, which is easily achieved  
with the Meade converter and appropriate extension tube (as supplied with the  
converter). Moderate deviations from this focal length will not have a drastic effect  
and so any F ratio from about F3.3 to F6 will give good results.  
The same equation can be used to calculate the amplification required for good  
planetary images. However, in this case, the shorter exposures allow us to assume a  
much better telescope resolution and 0.25 arc seconds per pixel is a good value to use.  
The calculation now gives the following result:  
F = 0.0096 * 205920 / 0.25 = 6754mm  
This is approximately F34 when used with a 200mm SCT and so we will need a 3.4 x  
Barlow lens. Such lenses are not available, but the common 3x version will be good  
enough for all practical purposes.  
An accessory that you will find valuable is the ‘M42 to T’ adaptor. These are short  
tubes that carry an external M42 thread at one end and an internal ‘T’ thread at the  
other end, and are available from most photographic supply shops. The T thread is the  
same diameter as the M42 (42mm x 1mm) thread but has a pitch of 0.75mm and is  
used for many astronomical accessories, such as telecompressors. An M42 to T  
adaptor will allow you to easily interface with virtually any device in the astronomical  
catalogue.  
Achieving a good focus:  
Your starting point will depend on the focus aids, if any, which you are using. With  
the par-focal eyepiece, you should slip the eyepiece into the drawtube and focus  
visually on a moderately bright star (about 3rd magnitude). Now withdraw the  
eyepiece and carefully insert the camera nosepiece until it is bottomed against the  
drawtube end and lock it in place. With the flip mirror unit, all that is needed is to  
swing the mirror down and adjust the focus until the star is sharply defined and  
centred in the viewing eyepiece. Now lift the mirror and you are ready to start  
imaging.  
SXV_M5C has a focus routine that will repeatedly download and display a 100 x 100  
pixel segment of the image at relatively high speed. This focus window may be  
positioned anywhere in the camera field and can be displayed with an adjustable  
degree of automatic contrast stretching (for focusing on faint stars). To use this mode,  
start up the software and select the MX camera interface (File menu). Set the camera  
mode to ‘Fast’ and select an exposure time of 1 second. Press ‘Take Picture’ and wait  
for the image to download. There is a good chance that your selected star will appear  
somewhere within the image frame and it should be close to a sharp focus. If the  
focus is still poor, then it may appear as a pale disk of light with a dark centre (the  
secondary mirror shadow in an SCT, or Newtonian). Now select the ‘File’ menu again  
and click on ‘Focus frame centre’; you can now use the mouse pointer to click on the  
star image and the new focus frame co-ordinates will be displayed. Now return to the  
camera interface window and click on ‘Start’ in the Focus frame. The computer will  
now display a continuous series of 100 x 100 pixel images in the focus window and  
you should see your selected star appear somewhere close to the centre. A ‘peak  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
value’ (the value of the brightest pixel) will also be shown in the adjacent text box and  
this can be used as an indication of the focus accuracy. Although the peak value is  
sensitive to vibration and seeing, it tends towards a maximum as the focus is  
optimised. Carefully adjust the focus control on your telescope until the image is as  
sharp as possible and the peak value reaches a maximum. Wait for any vibration to  
die down before accepting the reading as reliable and watch out for bursts of bad  
seeing, which reduce the apparent focus quality. Quite often, the peak value will  
increase to the point where it is ‘off scale’ at 4095 and in this case you must halt the  
focus sequence and select a shorter exposure if you wish to use the peak value as an  
indicator. Once you are happy with the focus quality achieved, you might like to trim  
the settings of your par-focal or flip mirror eyepiece to match the current camera  
position. Although you can reach a good focus by the above method, many observers  
prefer to use additional aids, such as Hartmann masks (an objective cover with two or  
three spaced holes) or diffraction bars (narrow parallel rods across the telescope  
aperture). These make the point of precise focus easier to determine by creating  
‘double images’ or bright diffraction spikes around stars, which merge at the setting  
of exact focus. The 12-16 bit slider control allows you to adjust the contrast of the  
focus frame for best visibility of the star image. It defaults to maximum stretch (12  
bits), which is generally ideal for stars, but a lower stretch value is better for focusing  
on planets.  
Taking your first astronomical image:  
I will assume that you are now set up with a focused camera attached to a telescope  
with an operating sidereal drive. If so, you are now in a position to take a moderately  
long exposure of some interesting deep-sky astronomical object (I will deal with  
planets later!). As most drives are not very accurate beyond a minute or two of  
exposure time, I suggest that you find a fairly bright object to image, such as M42,  
M13, M27 or M57. There are many others to choose from, but these are good  
examples.  
Use the finder to align on your chosen object and then centre accurately by using the  
focus frame and a short exposure of between 1 and 5 seconds. The ’12-16 bit’ slider  
in the focus frame allows you to adjust the image contrast if you find that the object is  
too faint with a short exposure. Once properly centred and focused, take an exposure  
of about 60 seconds, using the ‘Fast’ mode and observe the result. Initially, the image  
may appear rather barren and show only a few stars, however, there is a great deal of  
data hidden from view. You can get to see a lot of this, without affecting the image  
data, if you go to the ‘View’ menu and select ‘Auto Contrast Stretch Image’. The faint  
image data will then appear in considerable detail and I think that you will be  
impressed by the result!  
If you are happy with the image, go to the ‘File’ menu and save it in a convenient  
directory.  
Now you need a ‘dark frame’, if the best results are to be extracted from your raw  
image. To take this, just cover the telescope objective with the lens cap, or drop the  
flip mirror to block the light path to the CCD (make sure that this is light tight), and  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
take another 60 second exposure. This image will be a picture of the dark signal  
generated during your exposure and it should be saved with your image for use in  
processing the picture. The SXV-M5C generates very little dark signal and so dark  
frames are not essential for short exposures of less than a few minutes, but it is a good  
idea to record at least one for each exposure time used during an imaging session. As  
variations in ambient temperature will affect the dark signal, it is best to take the dark  
frames within a few minutes of capturing your images. For the same reason, it is not  
wise to use ‘old’ dark frames if you want the best possible results, however, some  
software allows you to scale library dark frames to match the image (e.g. AstroArt).  
‘Flat fields’ are often recommended for optimising the results from your CCD  
camera, but these are generally less important than dark frames, especially if you  
make sure that the optical window of the camera is kept dust-free. The purpose of a  
flat field is to compensate for uneven illumination and sensitivity of the CCD and it is  
better to avoid the need for one by keeping the optics clean and unvignetted. I will  
ignore flat fielding for current purposes and describe the process in detail at a later  
stage.  
Processing the deep-sky image:  
1) Make sure the ‘Auto Contrast Stretch’ is switched off and load your image into  
SXV_M5C. Select ‘Merge’ and then ‘Subtract Dark Frame’. Pick the appropriate dark  
frame and the software will then remove the dark signal from your image, leaving it  
somewhat darker and smoother than before.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
2) The resulting image will probably look faint and dull, with a bright  
background due to light pollution. It is now time to process the ‘luminance’  
(brightness and contrast) of the image to get the best visual appearance. First,  
use the ‘Normal’ contrast stretch to darken the background by setting the  
‘Black’ slider just below the main peak of the histogram. Alternatively, you  
can use the ‘Remove Background’ option to let the software decide on the best  
setting. This will greatly reduce the background brightness and the image will  
begin to look rather more attractive. You can now try brightening the  
highlights with another ‘Normal’ stretch, in which you bring down the ‘White’  
slider to just above the main image peak. The best setting for this is rather  
more difficult to guess and you may need several attempts before the result is  
ideal. Just use the ‘Undo last filter’ function, if necessary, to correct a mistake.  
3) The image will now look quite impressive and I hope that you are pleased with  
your first efforts! Further small refinements are usually possible and you will become  
expert at judging the best way to achieve these as your experience increases. As a  
rough guide, the ‘Filters’ menu can be used to sharpen, soften or noise reduce the  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
image. Strong ‘High Pass’ filters are usually not a good idea with deep sky images, as  
the noise will be strongly increased and dark rings will appear around the stars, but a  
‘Median’ filter can remove odd speckles and a mild ‘Unsharp Mask’ (Radius 3, Power  
1) will sharpen without too much increase in noise.  
Other things to try, include adjustment of the colour saturation and summing several  
images for a better signal to noise ratio. Summing can be done in the ‘Merge’ menu  
and involves loading the first (finished) image, selecting a reference point (a star) then  
loading the second image and finding the same star with the mouse. Once the  
reference is selected, you can either add directly, or average the images together.  
Averaging is generally better, as you are less likely to saturate the highlights of the  
picture. The signal-to-noise ratio will improve at a rate proportional to the square root  
of the number of summations (summing 4 images will double the signal-to-noise), but  
different exposures must be used. Summing an image with itself will not change the  
S/N ratio!  
Although I have concentrated on the use of a telescope for deep-sky imaging, do not  
forget that you have the option of using an ordinary camera lens for impressive wide-  
field shots! A good quality 200mm F3.5 lens with an infrared blocking filter will yield  
very nice images of large objects, such as M31, M42, M45 etc. If you cannot obtain a  
large IR blocker for the front of the lens, it is quite acceptable to place a small one  
behind the lens, inside the adaptor tube.  
Taking pictures of the planets:  
Planetary imaging is in many ways quite different from deep sky imaging. Most deep  
sky objects are faint and relatively large, so a short focal length and a long exposure  
are needed, while planets are bright and very small, needing long focal lengths and  
short exposures. High resolution is critical to achieving good results and I have  
already shown how a suitable focal length can be calculated and produced, using a  
Barlow Lens.  
Many camera users comment on the difficulty of finding the correct focus when  
taking pictures of Jupiter etc. This is usually due to poor seeing conditions, which are  
only too common, but may be due in part to poor collimation of your telescope.  
Please ensure that the optics are properly aligned as shown by star testing, or by using  
one of the patent collimation aids that are widely available. It is also better to use a  
star for initial focusing, as planetary detail is difficult to judge in bad seeing. Although  
the star will also suffer from blurring, the eye can more easily gauge when the most  
compact blur has been achieved!  
You could begin by imaging lunar craters, but the colour content is low and so I  
recommend Jupiter, Saturn or Mars. The rapid variations of seeing which accompany  
planetary imaging, will ruin the definition of about 95% of your images and so I  
recommend setting the camera to run in ‘Autosave’ mode. This will automatically  
take a sequence of images and save them with sequential file names in your  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
‘Autosave’ directory. Dozens of images will be saved, but only one or two will be  
satisfactory for further processing.  
To start the Autosave process, call up the SXV Camera Interface and select the  
‘Continuous Mode’ check box at the top (make sure the rest are unchecked). Now  
check the ‘Autosave Image’ checkbox near the bottom of the window. If you now  
click on ‘Take Picture’ the automatic sequence will begin and will not stop until you  
press a computer key. The images will be saved in FITs format with sequential names  
such as ‘Img23, Img24….’ and will be found in the ‘Autosave’ directory (or a sub-  
directory of Autosave, set up in the program defaults menu).  
The exposure time needed for good planetary images is such that the image histogram  
has a peak value at around 127 and does not extend much above 200 (Ignore the  
major peak near zero, due to the dark background). If you use too short an exposure  
time, the image noise level will be increased, and if too long a time is used you will  
saturate the highlights and cause white patches on the decoded image. With the  
recommended focal length, Jupiter and Mars will both need an exposure time of  
between 0.1 and 1 seconds and Saturn will need between 0.5 and 2 seconds.  
Processing a planetary image:  
Planetary images have one major advantage over deep sky images, when you come to  
process them – they are MUCH brighter, with a correspondingly better signal to noise  
ratio. This means that aggressive sharpening filters may be used without making the  
result look very noisy and so some of the effects of poor seeing can be neutralised.  
A raw image  
Try applying an ‘Unsharp Mask’ filter with a radius of 5 and a power of 5. This will  
greatly increase the visibility of any detail on the planet, but the optimum radius and  
power will have to be determined by experiment. In general terms, the larger the  
image and the worse the seeing, then the wider the radius for best results. My Jupiter  
shots are usually about half the height of the CCD frame and I find that the ‘radius 5,  
power 5’ values are good for most average seeing conditions. If you have  
exceptionally good conditions, then a reduction to R=3, P=3 will probably give a  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
more natural look to the image, as too large a radius and power tends to outline edges  
with dark or bright borders.  
As a finishing touch, the application of a Median filter or a Weighted Mean Low Pass  
filter can be useful to smooth out the high frequency noise after a strong Unsharp  
Mask.  
As with deep-sky images, it is advantageous to sum planetary images together to  
improve the signal to noise ratio. In this case, the ‘averaging’ option should always be  
used, or the result is likely to exceed the dynamic range of the software and saturate  
the highlights. Aligning the images is always something of a problem, as there are  
rarely any stars to use when imaging the planets, but Jupiter’s satellites can be useful  
reference points. Otherwise, you will have to find a well-defined feature on the planet,  
or estimate where the centre of the disk is located. Some more sophisticated software  
can automatically align planetary images, but I do not find it especially difficult to do  
by eye.  
*********************************************************************  
Other features of SXV_M5C  
‘Slew & Sum’ imaging:  
The SXV-M5C can be used in an automatic image-stacking mode, called ‘Slew &  
Sum’. The camera is set to take several sequential exposures, which are automatically  
‘slewed’ into alignment and then summed together by the software. This mode can  
help to overcome a poor RA drive by summing images that have exposure times  
shorter than the drive error period. The resulting image has more noise than a single  
exposure of the same total length, but this method of imaging is still an effective way  
of making long exposures.  
To take an S&S image, go to the camera interface window and select an exposure  
time for one image of the sequence. Do not use a very short exposure time, as the  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
read-out noise will become dominant. About 30 seconds is a reasonable minimum.  
Now go to the ‘Multiple Exposure Options’ and select a number of exposures to take.  
You can also select to average the images, rather than adding them, and there is a  
‘Alternative Slew Mode’ available, which uses the correlation of image areas, rather  
than a single star. This mode can be better in dense star fields.  
Another option is ‘Auto remove dark frame’. This is advisable with S&S images, as  
the slewing will mis-register the images with a single dark frame that is applied to the  
finished sequence. To use this option, you will need a dark frame, taken with the same  
exposure time as a single image from the sequence. This is stored on drive C with the  
name ‘dark.def’  
Now click on ‘Take Photo’ and the sequence will begin.  
Taking and using a flat field:  
Flat fields are images, which display only the variations of illumination and  
sensitivity of the CCD and are used to mathematically modify a wanted image in such  
a way that the errors are removed. Common flat field errors are due to dust motes on  
the camera window and vignetting effects in the optical system of the telescope. Dust  
motes act as ‘inverse pinholes’ and cast out-of-focus images of the telescope aperture  
onto the CCD chip, where they appear as shadow ‘do-nuts’. Most optical systems  
show some vignetting at the edges of the field, especially when focal reducers are  
used. This causes a brighter centre to show in images, especially when there is a lot of  
sky light to illuminate the field.  
If dust motes are your main problem, it is best to clean the camera window, rather  
than to rely on a flat field to remove the do-nuts. Flat fields always increase the noise  
in an image and so physical dust removal is the best option. If you have serious  
vignetting, first check whether the optical system can be improved. The most likely  
cause of this problem is trying to use too powerful a degree of optical compression  
with a focal reducer and you might want to try moving the camera closer to the  
reducer lens.  
If you really do need to use a flat field for image correction, then it must be taken with  
care. It is most important that the optical system MUST NOT be disturbed between  
taking your original images and taking the flat field. Any relative changes of focus  
and rotation etc. will upset the match between flat field and image and the result will  
be poor correction of the errors. The other necessity for recording a good flat field is a  
source of very even illumination for the telescope field. This is surprisingly difficult  
to achieve and many designs of light source have appeared in the literature and on the  
Web. These usually consist of a large wooden box, containing several lamps and an  
internal coating of matt white paint, which is placed over the objective of the  
telescope to provide an evenly illuminated surface. These can work well, but I prefer a  
simpler method, as follows:  
Most imaging sessions begin or end in twilight and so the dusk or dawn sky can  
provide a distributed source of light for a flat field. However, using the sky directly is  
likely to result in recording many unwanted stars, or patches of cloud etc., so a  
diffuser needs to be added to the telescope. An ideal material is Mylar plastic  
draughting film, obtained from an office supplies warehouse. It is strong and water  
resistant and can be easily replaced if damaged. Stretch a piece of the film loosely  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
across the aperture of your telescope and point the instrument high in the sky, to avoid  
any gradient in the light near the horizon. Now take several images with exposure  
times adjusted to give a bright, but not overloaded, picture. Averaging flat field  
together is a good way to reduce their noise contribution and so recording 4, or more,  
images is a good idea.  
To use your flat fields, they must first have a dark frame subtracted. Although this  
may appear to be unimportant with such brightly lit and short exposures, there is the  
‘bias offset’ of the camera in each image and this can produce an error in the final  
correction. As we are mainly interested in the bias, any very short exposure dark  
frame will give a good result. The dark subtracted images should then be averaged  
together before use.  
After the above procedures have been executed, the flat field will be ready for use.  
Load up your image for processing, subtract the dark frame and then select ‘Apply  
flat field’ in the ‘Merge’ menu. The result should be an image with very little sign of  
the original artefacts.  
********************************************************************  
The accessory ports  
The SXV-M5C is provided with two ports for use with accessories. The Autoguider  
output port is a 6 way RJ11 socket, which is compatible with the standard autoguider  
input of most telescope mounts. It provides 4 active-low opto-isolator outputs and a  
common return line, capable of sinking a minimum of 5mA per output. This socket  
may be used for telescope control if the SXV-M5C is employed as an autoguider, but  
is primarily intended to be the control output for the optional add-on autoguider  
camera head, available for use with the SXV-M5C.  
The high density parallel port socket provides both control and power for the add-on  
autoguider, but also includes a pair of serial ports for use with other devices.  
Using the built-in serial ports  
The SXV-M5C incorporates two fast serial ports for use with external accessories.  
The ports are available on 5 pins of the 18 way connector that is provided for the  
autoguider and may be accessed by plugging in a ‘serial port divider box’. The divider  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
box and cables are available as an accessory and may be chained in series with the  
autoguider cable, when the guider is in use, or may be used on its own.  
The two serial connections are in the form of standard RS232 PC style plugs and  
provide TX, RX and Ground connections at RS232 levels. Access is via commands  
sent through the USB connection and, at the time of writing, is limited to any serial  
controls that are provided by the SXV software. It is expected that many more  
functions will be added as the software is upgraded.  
*********************************************************************  
STAR 2000  
The SXV-M5C may be used with our patented self-guiding system ‘STAR 2000’.  
This can greatly ease the process of recording long exposure deep-sky images.  
Using ‘STAR 2000’ self-guiding with the SXV-M5C  
How S.T.A.R. 2000 works:  
S.T.A.R. 2000 is a unique and patented method of automatically controlling your  
telescope drives, while capturing a long exposure image with your Starlight Xpress  
CCD camera. Unlike off-axis guiding devices and dual-CCD self-guiding cameras,  
S.T.A.R. 2000 can guide on almost any object, which is visible within the CCD  
frame! You have the entire CCD field of view to choose from and can even select a  
slowly moving target, such as a comet nucleus, or asteroid, to guide on during the  
exposure.  
The principle of S.T.A.R. is based on the special CCD structure of the chips used in  
our SXV_M5, M7 and M9 cameras and it cannot be used with ‘full frame’ CCDs,  
such as the popular Kodak devices. It is also incompatible with our HX516 camera.  
The M5, M7 and M9 use ‘Interline Interlaced’ CCD chips, which are constructed with  
each pixel split into two vertically stacked halves. Each half can be ‘read out’  
independently, so it is possible to integrate a long exposure on one field of half pixels,  
while the other field is read out at short intervals and the data used for guiding the  
telescope. Half way through the exposure, we can read out the contents of the  
integrating field, swap fields, and integrate the rest of the exposure on the other field.  
This preserves the best image resolution and eliminates ‘aliasing’ effects.  
To give a fast guider update rate, the guiding field is read out as an 80x40 window  
around the guide object, while the unused lines are ‘dumped’. Using this technique, it  
is possible to feed corrections to the telescope drive as often as one every second  
when guiding on a fairly bright star (typically about mag. 11). The sub-pixel guiding  
accuracy of S.T.A.R. 2000 will give you tightly defined, round star images, however  
long the exposure time that you use!  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
The advantages of S.T.A.R. are very great, but there are two negative aspects, which  
you should be aware of. The main loss is in the sensitivity of the CCD, as only half of  
the pixel area is integrating an image at any one time. This is slightly offset by the  
halving of the dark current, which also results, and can be completely compensated  
for by increasing the exposure time – not a big problem when the camera can guide  
itself! The other problem is that the CCD amplifier must be switched on momentarily  
to read out each guider frame. Despite the short times involved, this results in some  
contamination of the upper left hand corner of the image, by light emitted from the  
amplifier transistors (electro luminescence), and this needs the subtraction of a special  
dark frame to remove it. However, the glow is quite faint and may be ignored on  
many images, or it can be removed with the ‘Gradient filter’ in the ‘Filters’ menu.  
What you need:  
To use S.T.A.R. 2000, you must have a telescope with ‘Auto guider’ capability. Most  
modern SCTs have this facility in the form of a 6 pin ‘RJ11’ telephone style  
connector on the mounting base or handset. If your ‘scope is ‘ST4 compatible’ it  
should work with S.T.A.R. 2000. Adaptors for other mounts, such as the Vixen  
Skysensor, are available from Starlight Xpress. In the case of a ‘difficult’ mount, an  
add-on relay box is available to switch higher currents and opposite polarity circuits.  
The system has been tested with the LX200, LX50 and Celestron CI700 German  
mounts with good results, but almost any modern mount will work well. Please note  
that the RJ11 cable supplied with the camera has the connectors fitted on opposite  
sides of the 6 way cord – other cables may not be compatible!  
Setting up the system:  
For best results, it is important to set up your telescope mounting as accurately as  
possible. Alt-Az mounts can be used with S.T.A.R. 2000, but will cause field rotation  
during exposures and are often rather poor at smooth tracking. We recommend that  
you always use an equatorially mounted ‘scope, with its polar axis accurately aligned  
on the pole. If your mount is prone to sudden shifts of aim point during tracking,  
usually due to poorly made gears or bearings, then S.T.A.R. will be unable to fully  
compensate and some trailing will result. Slow and smooth errors in position are well  
corrected and so this is what you should aim for. Check that all your drive gears are  
firmly fixed to their shafts (loose gears are surprisingly common!) and that they  
engage closely, without binding. The tracking of many mounts can be improved by  
adding a deliberate bias to the East. A small weight on the Eastern fork tine will  
usually be effective.  
Connect up the computer and camera in the usual way and install the camera onto the  
telescope. Next, take the 6 way RJ11 telephone lead and plug one end into the guider  
output of the SXV camera. This output is a ‘switched’ signal, compatible with inputs  
designed for use with an ST4 guider. It is also possible to use a serial connection to an  
LX200 compatible RS232 input, but to do this you need to have a serial port to RJ11  
cable from the back of the computer to the RS232 input of the mount. This connection  
allows other ‘goto’ control signals to be sent to the mount, but may be less convenient  
if you do not require this facility. Which output you use will also depend on your  
telescope, but the Meade LX200 and its clones are compatible with serial control,  
although the LX200GPS still has a software issue at the time of writing. All other  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
mounts will use the guider output from the camera. Once the above connections have  
been made, you are ready to start up the system.  
Starting to guide:  
Power up the camera and computer, and start the telescope drive. Click on ‘Set  
Program Defaults’ and examine the current settings. In the ‘Telescope Guiding’ box,  
set the interface selection to ‘LX200’, or ‘Via Control box’ (ST4 output of camera), as  
appropriate. Also select ‘COM1’ or ‘COM2’ if using serial control, according to  
availability - ‘COM1’ is the 9 pin port provided on the rear panel of most portable PC  
computers.  
Now adjust the other values as follows:  
1. Set ‘RA Pixels per sec’ and ‘Dec Pixels per sec’ to 5.  
2. Set all backlash and hysteresis values to 0.  
3. Set ‘Ignore drift < 1 pixel’ to OFF.  
4. Set ‘70mS delay between direction changes’ to ON.  
5. Set ‘Default guide training time’ to 2 secs.  
These values can be refined later, but should work reasonably well with most  
telescopes.  
You can now test communications between the computer and telescope mount, as  
follows:  
1. Press ‘Set slew values’, followed by ‘Save Program Defaults’.  
2. Select ‘Telescope control’ in the ‘File’ menu.  
3. Press each button in turn and observe the LED lamp at the rear of the camera.  
As each is pressed, the lamp will brighten and change colour between red and  
green. The telescope will also begin to slew in the appropriate direction. This  
slew will be slow (unless you have deliberately selected a fast slew mode via  
the telescope controls) and so you will need to observe it through the telescope  
eyepiece, by watching stars drift by. If the LX200 output is in use, the LED  
will not respond, but the ‘scope will still slew correctly.  
If all is well, you can proceed to testing the guiding system itself, otherwise, check  
your setup and confirm that the correct COM port etc. is selected.  
Refit the CCD camera to the telescope and rotate it so that the mounting bracket is  
aligned approximately East-West. Focus in the usual way on a star and then point the  
‘scope towards the object you have selected for imaging. I recommend something  
near the celestial equator and with a reasonable number of useful guide stars around  
it, to make life a little easier!  
Take an image of the field, using an exposure time of 1 second and selecting ‘Auto  
contrast stretch’ in the ‘View’ menu. Several stars should be easily visible in the  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
displayed image, but, if not, try increasing the exposure time a little. Remember that  
the ideal guide star is one that is bright enough to be easily detected in a 1 second  
exposure, or less.  
Once you have the test image and can see an appropriate guide star, go to the ‘File’  
menu and click on ‘Select guide star’. Now click the mouse on the image, with the  
pointer on your selected star. The pointer will jump onto the star and a message box  
will show its co-ordinates in a message window – press ‘OK’ to confirm the selection.  
You have now selected the guide object and are ready to start an exposure.  
Call up the camera control panel and select a 1 second (or the length necessary for  
your guide star) exposure time. Click on the check box ‘Self guide next exposure’ and  
‘1 second’ should appear in the self guide exposure box. Now set the exposure for the  
image (try 5 minutes as a good starting point) and click on ‘Take picture’.  
The control panel will disappear and be replaced by the guider window, with a set of  
number boxes above it. The guider software will now attempt to centre an 80 x 40  
pixel box around the guide star and this will appear in the guider window after a few  
seconds delay. The number boxes will also begin to show the star co-ordinates and the  
differential guiding error as each new guide field is displayed.  
If all is well, the error numbers will remain at generally less than 1 pixel and the star  
image will sit steadily at the same location in the guide box. If, however, the star  
begins to drift away, it is possible that your drive guide directions are reversed in  
either RA or DEC (or both). Press ‘ESC’ to stop the exposure and go back to the ‘Set  
Program Defaults’ menu, where you can use the ‘Swap n/s direction’ and ‘Swap e/w  
direction’ check boxes to reverse the appropriate drive. Another problem, which can  
arise, is that the star may remain close to the correct position, but will oscillate around  
it by two or three pixels, rather than holding nearly steady. This can be due to several  
different faults, such as poor drive accuracy, windy conditions, or bad seeing, but may  
also be caused by an excessive ‘Loop gain’ in the self-guider feedback loop. Try  
increasing the ‘Pixels per second’ values in the appropriate default setting box, until  
stable following is achieved. Once the guider is set up correctly, it should hold a guide  
star within 1 pixel of its correct position indefinitely, and you can try taking test  
exposures of various objects to confirm its accuracy.  
After your first test of the self guider, there is a good chance that the set-up will still  
need some optimising. You have the option of manually setting test values of  
backlash and hysteresis, or using the ‘Training’ routine in the software. Backlash is  
the time delay between a reversal of a drive motor and the start of a positional  
correction of the telescope. Hysteresis is the time it takes for a motor to stop, after the  
power is removed. Many mounts have internal software to compensate for these  
errors, but you may need to set values other than zero to get the best performance  
from less sophisticated ones.  
The ‘Training’ option can be used as follows:  
Select a star to guide on, and then the drive training period, using the ‘radio buttons’.  
The best training time will vary with the response speed of the mount, but use as long  
a time as possible, consistent with not losing the guide star out of the guide window.  
Start the training cycle and the software will then sequentially drive the telescope in  
all four directions, while recording the displacement of the reference star. After the  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
cycle has completed, the optimum correction speeds, backlash correction and  
hysteresis values will have been calculated and inserted into the default boxes. Note  
that the pixels per second rate for the R.A. correction will vary with the cosine of the  
declination angle, so you may need to alter this value, or re-train the system when  
changing between objects at widely different declinations.  
Exposure times and image calibration  
S.T.A.R. 2000 will enable you to greatly extend the exposure times of astronomical  
images and so detect much fainter objects. The limiting factor is set largely by the  
increasing effect of light pollution on these extended exposures, but dark sky sites will  
permit 30 minutes, or more, to be used. You will also begin to see signs of amplifier  
luminescence at the upper left-hand corner of your images and this will make dark  
frame subtraction more important than usual.  
The software includes an option to generate properly matched dark frames, by  
recording the number of guiding downloads executed during the taking of the image  
and using this to add the correct amount of amplifier glow to the resulting dark frame.  
To use this option, you must record the dark frame immediately after the ‘light  
frame’, or the download count will be lost. Simply cover the ‘scope aperture, select  
‘Take matching dark frame’ in the self guider part of the camera control interface and  
press ‘Take Photo’. Application of the ‘Gradient filter’ (under the Filter Menu) can be  
used as a final ‘tweak’, if necessary.  
Flat field frames can be taken in the usual way, and are not affected by the use of  
S.T.A.R. 2000.  
A clip from a self-guided ‘STAR 2000’ SXV-M5C image  
*********************************************************************  
Using the add-on autoguider:  
An alternative to STAR2000 and a very useful accessory is the add-on autoguider  
head, which takes its power and control signals directly from the SXV camera, via the  
18 way socket on its rear panel. The autoguider is only 1.25” in diameter and has a  
video style ‘CS’ mount thread in its nose, so video lenses may be attached. The guider  
may be used with either an off-axis prism assembly mounted in front of the SXV  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
camera, or with a separate guide telescope, rigidly mounted alongside your imaging  
telescope. I personally use it with an 80mm aperture F5, inexpensive refractor as a  
guide ‘scope, but a shorter focal length lens will make more guide stars available in  
any given region of sky (See the picture below).  
To use the autoguider, first orient it so that the connector plug is roughly parallel to  
the declination axis of your mount. This is not absolutely essential, as the training  
routine will learn the angle of the head and compensate for it, but it is easier to  
understand the motion of the guide star if the guider frame is aligned with the RA and  
Dec axes. Now connect the head to the SXV camera, using the 18 way connector lead,  
including the port divider box, if it is to be used.  
The recommended way of connecting the autoguider output to the mount is to use an  
RJ11 telephone lead between the socket on the SXV camera and the autoguider input  
of your mount. This output is ‘active low’ (i.e. the control relays pull the guider inputs  
down to zero volts when applying a guide correction) and matches most of the  
autoguider inputs on commercial mounts. If ‘active high’ inputs are needed, or a very  
low control voltage drop is essential, then you will need to add a Starlight Xpress  
‘relay box’ between the guider output and the input to the mount. Please contact your  
local distributor if a relay box is required. Some mounts (Vixen, for example) use a  
similar guider input socket, but have re-arranged connections. Details are given on our  
web pages at the end of the ‘STAR2000’ section.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
The autoguider installed on a 80mm refractor guide ‘scope in the author’s garden  
To use the autoguider, please proceed as follows:  
1) Having started the SXV-M5C software, open the autoguider control panel by  
clicking on the autoguider menu button.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
The autoguider control panel with a guide star selected  
2) Press the ‘Start’ button and a series of 1 second exposure guider images will  
begin to appear in the picture frame. If the images look too dim, use the  
‘Stretch Image’ slider to increase its contrast and brightness until the noise  
begins to be visible.  
3) If you haven’t focused the guider lens or ‘scope, move the mount until a bright  
star is visible on the guider image and then adjust the focus until it is as sharp  
as possible.  
4) At this point, you may want to test the guiding control by pressing the manual  
‘Move Telescope’ buttons at the bottom left corner of the control panel. You  
can watch the position of any stars in the guider image and confirm that they  
move in response to the buttons. The movement should be slow if the correct  
guiding rate is selected on your mount (typically 2x sidereal). Adjust this, if  
necessary.  
5) Move the mount until the required object for imaging is properly framed in the  
main CCD image (leave the guider menu and use the main camera control  
panel, as necessary).  
6) Re-open the guider control panel, start imaging and try to locate a clearly  
visible guide star. If necessary, make adjustments to the guide telescope or off-  
axis guider until one is found.  
7) Press ‘Stop’ and then press ‘Select Guide Star’. Use the mouse to left click on  
the selected star and a green cross will highlight it and the co-ordinates will  
appear in the text boxes above the image window.  
8) The various guiding rate defaults, listed on the right-hand side of the control  
panel, are unlikely to be perfect for your particular telescope and mount. You  
have the option of manually selecting values, or asking the software to attempt  
to determine what they should be. This is done by pressing the ‘Train’ button  
and waiting for the software to complete a sequence of automatic moves and  
calculations. The training will also determine the angle at which the guide  
camera is oriented with respect to the RA and Dec axes. If you do not wish to  
train the system at this time, the default values of 6 pixels per second will  
serve as a starting point.  
9) Now press ‘Go to main camera’ and the guider control panel will be replaced  
by the camera control panel. Set the required exposure time for the image (say  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
5 minutes) and press the ‘Autoguide next image’ button. The autoguider  
window will reappear and, after a few seconds, you should see error values  
appearing in the text windows at the top. The guide star will be fairly close to  
the green cross, although not necessarily accurately centred, and you should  
see the power/ guide LED on the rear of the camera brighten and change  
colour with each correction.  
10) If the star begins to drift away from the cross, despite the corrections being  
made, the chances are that the N/S and/or E/W directions are set wrongly.  
Judge which axis is incorrectly set by observing the direction of the drift and  
then stop the exposure by pressing ‘Esc’. Open the guider control panel and  
check the appropriate swap box(es). After this operation, you will probably  
need to find the guide star again by taking a guider image and reselecting the  
star, as before. Now return to the main camera menu and try the ‘Autoguide  
next image’ button again.  
11) Once guiding is taking place without problems, the main exposure can be  
allowed to finish and, if all is well, you should see an image with tiny circular  
stars.  
If the stars are not circular, you may need to alter the guiding parameters, or  
investigate the rigidity and drive performance of your mount. A lot of information  
can be deduced by watching the behaviour of the guide star in the guider frame. If  
it is continually moving between two locations, either side of the green cross, then  
the RA or Dec pixels per second value is set too low. The higher these values are  
set, the gentler the guiding becomes. Too low a value will cause an over-  
aggressive correction to be made and result in oscillation of the star position  
between two points.  
Another source of guiding errors can be a too accurately balanced telescope  
mount! Good balance can result in the telescope mount ‘bouncing’ between the  
gear teeth as corrections are made. A simple fix is to add a weight of about 0.5kg  
(1 pound) on the eastern end of the declination axis, so that there is always some  
pressure acting against the gear teeth.  
Getting a good result from an autoguider will often entail a lot of detective work  
to eliminate the sources of gear error, telescope flexure, mirror shift etc., but the  
final result is well worth the effort!  
*********************************************************************  
Camera maintenance:  
Very little maintenance is needed to keep the SXV-M5C in excellent operating order,  
however two problems, which are common to all CCD equipment, are likely to show  
up on occasion. These are dust and condensation.  
Removing Dust:  
1) Dust can be deposited on either the optical window (not a big problem to cure), or  
on the CCD faceplate (difficult to eliminate entirely). When small particles collect on  
the window they may not be noticed at all on deep sky (small F ratio) images, as they  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
will be very much out of focus. However, if a powerful contrast boost of the image is  
carried out, they may well begin to show as the shadow ‘Do-nuts’ mentioned earlier.  
Images taken with a large F ratio optical system are more likely to be affected by such  
dirt, owing to the smaller and sharper shadows that they cast. There is no great  
difficulty in removing such particles on the outside surface by the careful use of a lens  
cleaning cloth or ‘air duster’ and so you should have little trouble with this aspect of  
maintenance. Dust on the CCD faceplate is a much greater nuisance, as it casts very  
sharply defined and dark shadows and it entails dismantling the camera to get rid of  
it! To clean the CCD you will need a good quality lens cloth (no silicone) or tissues  
and some high-grade isopropyl alcohol. A very suitable cloth is the ‘Micro-Fibre’  
type marketed by PENTAX etc., and suitable alcohol is available from TANDY  
(Radio Shack) etc. as tape head cleaning fluid. A bright light and a strong  
watchmakers eyeglass will also be found essential.  
Procedure:  
1) Disconnect the lead from the camera head and remove it from the telescope. Place  
it on a table with the optical window facing downward.  
2) Remove the two M3 screws from the camera back plate and ease the plate out of  
the camera body. You may need to press down with a finger on the USB socket while  
pulling up on the camera barrel to overcome the friction.  
3) Withdraw the body cylinder and unscrew the two long spacer pillars from the heat  
sink plate assembly.  
4) The entire camera electronic assembly can now be lifted away from the camera  
front barrel and the CCD will be readily accessible. Note that a layer of white heat-  
sink compound is applied to the periphery of the heat sink disc and this should be left  
undisturbed by subsequent operations.  
5) You can now closely examine the CCD faceplate under the spotlight using the  
watchmaker's glass when any dust motes will show clearly. If there is only an odd  
particle or two and the CCD is otherwise clean, carefully brush away the dust with a  
corner of your lens cloth. A smeared or very dusty CCD will need a few drops of  
alcohol to clean thoroughly and you may have to make several attempts before the  
surface is free of contamination. One gentle wipe from one end to the other, with no  
return stroke, will be found to be the most effective action. DO NOT rub vigorously  
and be very careful to avoid scratching the window.  
6) Before re-assembly, make certain that the inside surface of the front window is also  
clean, and then carefully replace the camera front barrel and screw it into place. (If the  
heat sink seal is disturbed, renew it with fresh compound before reassembling).  
7) Replace all the camera parts in reverse order and the job is done.  
Dealing with condensation:  
The SXV-M5C is designed to avoid condensation by minimising the volume of air  
trapped within the CCD cavity. This normally works quite well, but storage of the  
camera in a humid location can lead to the trapped air becoming moist by diffusion  
through the optical window mounting thread etc. and result in condensation on the  
CCD window. If this becomes a problem, try to store the camera in a warm, dry place,  
or in a plastic lunch box containing a sachet of silica gel desiccant.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
N.B. DO NOT leave the camera switched on for long periods between uses. The  
cold CCD will collect ice by slow diffusion through any small leaks and this will  
become corrosive water on the cooler and CCD pins when the power is removed. If  
substantial amounts of moisture are seen on the CCD, dismantle the camera and  
dry it thoroughly.  
*********************************************************************  
Alternative Software  
Although we hope that you will be satisfied with ‘SXV_M5C’, other companies are  
offering alternative software. The most active and successful of these is ‘AstroArt’ by  
MSB software. You can purchase AstroArt from many dealers Worldwide and more  
information may be obtained from their web site at http://www.msb-astroart.com  
Maxim DL is also a very popular option and may be purchased from many  
*********************************************************************  
Some details of the camera and CCD characteristics  
CCD type: Sony ICX405AK  
‘SuperHAD’ interline CCD imager with CMYG  
filters.  
CCD size:  
Pixel size:  
QE peak:  
Active area  
4.9 x 3.65mm  
9.8 x 6.3uM  
approx. 60% at 540nM  
Spectral response:  
Power consumption:  
220v / 110v AC @ 12 watts max., 12v DC @ 750mA  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handbook for SXV-M5C  
Issue 1 August 2004  
Dear User,  
Thank you for purchasing a Starlight Xpress CCD Imaging System. We are confident that you will gain  
much satisfaction from this equipment, but please read carefully the accompanying instruction manual  
to ensure that you achieve the best performance that is capable of providing.  
As with most sophisticated equipment a certain amount of routine maintenance is necessary to keep the  
equipment operating at its optimum performance. The maintenance has been kept to a minimum, and is  
fully described in the manual.  
In the unfortunate instance when the equipment does not perform as expected, may we recommend that  
you first study the fault finding information supplied. If this does not remedy the problem, then contact  
Starlight Xpress for further advice. Our message board service on the Starlight Xpress web site will  
often provide solutions to any problems.  
The equipment is covered by a 12-month guarantee covering faulty design, material or workmanship in  
addition to any statutory Consumer Rights of Purchasers.  
CONDITIONS OF GUARANTEE  
1) The equipment shall only be used for normal purposes described in the standard operating  
instructions, and within the relevant safety standards of the country where the equipment is used.  
2) Repairs under guarantee will be free of charge providing proof of purchase is produced, and that the  
equipment is returned to the Service Agent at the Purchaser’s expense and risk, and that the equipment  
proves to be defective.  
3) The guarantee shall not apply to equipment damaged by fire, accident, wear an tear, misuse,  
unauthorised repairs, or modified in any way whatsoever, or damage suffered in transit to or from the  
Purchaser.  
4) The Purchaser’s sole and exclusive rights under this guarantee is for repair, or at our discretion the  
replacement of the equipment or any part thereof, and no remedy to consequential loss or damage  
whatsoever.  
5) This guarantee shall not apply to components that have a naturally limited life.  
6) Starlight Xpress’s decision in all matters is final, and any faulty component which has been replaced  
will become the property of Starlight Xpress Ltd.  
For further info. or advice, please call:  
Mr Michael Hattey,  
Starlight Xpress Ltd.,  
The Office, Foxley Green Farm,  
Ascot Road, Holyport,  
Berkshire,  
England. SL6 3LA  
Tel: 01628 777126  
Fax: 01628 580411  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Personal Computer PN TPCi7W7 User Manual
Sony Home Theater System DAV DZ10 User Manual
Sony Printer DMP 1000 User Manual
SOYO Car Video System M17GS User Manual
Spirit CD Player PLAYER User Manual
Star Trac Exercise Bike S RB RECUMBENT BIKE User Manual
Stiga Lawn Mower 11 5234 23 User Manual
Sun Microsystems Network Card 805 1797 10 User Manual
Swann DVR DVR4 1300 User Manual
Sylvania TV DVD Combo 6615LDG User Manual