1. Introduction
2. RS-232C
Appendix............................................................................. 18
2-1. Communication Specifications .......................................... 1
2-2. Command Block Format.................................................... 2
2-3. Block Format ..................................................................... 3
2-4. Connection ......................................................................... 4
2-5. Communication Procedure ................................................ 4
2-5-1.
Outline of Communication ....................................... 4
2-6. Communication Rules ....................................................... 5
2-7. Approximate Return Waiting Times ................................. 5
3. NETWORK
3-1. Advertisement .................................................................... 6
3-1-1.
3-1-2.
Function .................................................................... 6
Setup Items ............................................................... 6
3-2. PJ Talk ............................................................................... 7
3-2-1.
3-2-2.
Function .................................................................... 7
Setup Items ............................................................... 7
3-3. SDAP Protocol................................................................... 8
3-4. SDCP Protocol ................................................................... 9
3-4-1.
Format ...................................................................... 9
3-4-1-1. Header ................................................................. 9
3-4-1-2. Community .......................................................... 9
3-4-1-3. Command .......................................................... 10
3-4-1-4. SET Request ...................................................... 11
3-4-1-5. GET Request ..................................................... 11
3-4-1-6. ERROR Response ............................................. 11
3-4-2.
Items ....................................................................... 12
3-4-2-1. Model Dependent Category .............................. 12
3-4-2-2. Equipment Information Acquisition (80**h) .... 12
3-4-2-3. Network Information Acquisition (90**h) ....... 13
3-4-3.
Error Code .............................................................. 14
3-4-3-1. Item Error .......................................................... 15
3-4-3-2. Community Error .............................................. 15
3-4-3-3. Request Error..................................................... 16
3-4-3-4. Network Error ................................................... 16
3-4-3-5. Comm Error....................................................... 17
3-4-3-6. NVRAM Error................................................... 17
VPL-VW100
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Introduction
This protocol manual describes the basic configuration and basic operations of various commands used
for projector. Projector can be controlled using the commands provided in “Appendix”. Using an external
CONTROLLER , etc., inputs can be switched and the power can also be turned on and off. In the follow-
ing paragraphs, “CONTROLLER” means an external device such as a PC which controls projector using
these commands.
2. RS-232C
2-1. Communication Specifications
<RS-232C Communication Signal>
. Full duplex communication channels (Flow control not performed.)
. Start-stop synchronism system
. Baud rate: 38.4 kbps (bits per second)
. The bit configuration is defined as follows.
1 START Bit + 8 DATA Bits + 1 PARITY Bit + 1 STOP Bit
START
BIT
D0
D1
D2
D3
D4
D5
D6
D7
PARITY STOP
(LSB)
(MSB) (EVEN) BIT
EVEN Parity ...... Total number of “1”s from D0 to D7 is an even number. 8 0
...... Total number of “1”s from D0 to D7 is an odd number. 8 1
VPL-VW100
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2-2. Command Block Format
The code from B0 to B7 as described below are transmitted.
Transmission from
the Master side
Reception in
the Master side
Reception in the Master side
(With Data)
B0
START CODE : 0xA9
ACK / NAK
B1
B2
ITEM NUMBER
SET / GET
DATA
ITEM NUMBER
REPLY
ACK
B3
B4
B5
DUMMY DATA
DATA
B6
B7
CHECK SUM
END CODE : 0x9A
B0 START CORD
Common in the all FORMAT
B6 CHECK SUM
B1 to B5 are calculated by OR;
<Example of Calculation>
0xA9
0xA9
Answer
1010
1010
1010
1001
1001
1001
0xA9
0xA9
0x9A
Answer
1010
1001
1011
1001
1010
1011
0xBB
B7 END CODE
Common in the all FORMAT
VPL-VW100
2
Download from Www.Somanuals.com. All Manuals Search And Download.
2-3. Block Format
Transmission from the Master side
Data transmission to the Projector
Start of Command
B0
START CODE
ITEM NUMBER
B1
B2
Set the Data Category Value desired.
Refer to the Appendix Table 1 for details.
SET: 0x00 (Set data)
GET: 0x01 (Get data)
SET / GET
DATA
B3
B4
B5
B6
B7
SET: Data to be set (Refer to the Appendix Table 2)
GET: Unused. Set Dummy data [0x00, 0x00]
Check Sum
CHECK SUM
END CODE
End of Command
Receive results of the data transmission from the Projector.
Start of Command
Reception in the Master side
B0
B1
B2
START CODE
ACK / NAK
Results correspond with the data transmission
Refer to the Appendix Table 3 for the data in detail.
[0x03]
B3
ACK
Express Reply data either of ACK, or NAK
B4
B5
B6
B7
This data does not mean any senses.
Dummy Data [0x00, 0x00] is stored.
DUMMY DATA
Check Sum
CHECK SUM
END CODE
End of Command
Receive data from the Projector
Start of Command
Reception in the Master side (With Data)
B0
B1
B2
START CODE
ITEM NUMBER
Data to acquire
Refer to the Appendix Table 1 in detail.
[0x02]
B3
REPLY
DATA
Express data to be Reply data
B4
B5
B6
B7
Received data
Refer to the Appendix Table 2 in detail.
Check Sum
CHECK SUM
END CODE
End of Command
VPL-VW100
3
Download from Www.Somanuals.com. All Manuals Search And Download.
2-4. Connection
<RS-232C Connection>
Communication is enabled by the use of a D-Sub 9 Pin cross (reverse) cable.
The pin assignment of D-Sub 9 Pin and D-Sub 25 Pin is as follows.
D-Sub 9 Pin D-Sub 25 Pin
Name
Grounding for safety protection or cable shield
Transmission data
Shell = FG
1
2
FG
TxD
3
2
7
8
6
5
1
4
9
3
4
5
6
RxD Reception data
RTS Transmission request
CTS Transmission permission
DSR Data set ready
GND for signal
DCD Data channel signal carrier detection
DTR Data terminal ready
7
8
20
22
SG
RI
Calling display (Presence/absence of calling signal)
Pins indicated as D-Sub 25 Pin are not used.
Assured cable length: 15 m (However, assurance may not be applicable for some cables.)
The software for controlling the projector from a PC is intended for performing transmission and recep-
tion for only the TxD and RxD lines.
Therefore there is no handshake normally performed by RS-232C.
2-5. Communication Procedure
2-5-1. Outline of Communication
All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the
command block format. Communication is started by the issue of a command at CONTROLLER and
ended when the return data is sent to CONTROLLER after DEVICE receives the command.
CONTROLLER is prohibited from sending several commands at one time. This means that after CON-
TROLLER sends one command, it cannot send other commands until DEVICE returns the return data.
DEVICE sends the return data after processing the command. The time from when CONTROLLER sends
the command until the return data is returned differs according to the contents of the command.
n
When Sircs Direct Command is sent, return data may not be returned in some cases.
VPL-VW100
4
Download from Www.Somanuals.com. All Manuals Search And Download.
2-6. Communication Rules
. When sending a command from CONTROLLER, the return data from PROJECTOR should be re-
ceived first before sending the next command. Even if the next command is sent before receiving the
return data, since PROJECTOR will not be able to receive that command, it does not return a response
to CONTROLLER. Consequently, no error code is also sent.
The following lists the approximate waiting times for PROJECTOR to return the return data after
CONTROLLER sends the command.
. When a communication error occurs, PROJECTOR ignores the data received until now, and set into the
reception standby state.
. For undefined commands or commends determined as invalid by PROJECTOR, PROJECTOR will
send the “NAK” return data to CONTROLLER .
. Take note that when data is written when the input signal of PROJECTOR is unstable, that data (value)
will not be incorporated.
. When INDEX specified SIRCS direct command is transmitted, leave an interval of 45 msec until the
next transmission. (Do not return the return data (ACK, NAK) when the SIRCS direct command is
received.)
2-7. Approximate Return Waiting Times
The await-return time is approx. 30 msec.
n
This is the case, unless the communications are interfered anyway.
VPL-VW100
5
Download from Www.Somanuals.com. All Manuals Search And Download.
3. NETWORK
This section describes the performance, operations and protocol to be used of advertisement and PJ Talk.
3-1. Advertisement
The advertisement service is provided to facilitate development of a PC application that can automatically
detect a projector on the network. This function is achieved by broadcasting the equipment information
periodically to the network.
3-1-1. Function
The equipment information shown below is transmitted as the broadcast packet periodically (at certain
intervals).
Information
Description
Category
Category of the equipment
Equipment name
Serial number
Installation information
Community
Name of the equipment
Serial number of the equipment
Installation location of the equipment
Community name of the equipment
Power status of the equipment
Power status
m
. The category of projector is 0x0a.
. The power status sets ffffh if communication error occurs.
Protocol
The SDAP protocol is defined in order to provide this service.
Item
Description
Protocol name
Transport
SDAP (Simple Display Advertisement Protocol)
UDP
Port number
53862 (Factory-shipments value)
Once every 30 seconds (Factory-shipments value)
Broadcast interval
3-1-2. Setup Items
The items that can be set for the advertisement service are described below.
Setup items
Description
Port No.
Interval
Port number
Broadcast interval
Broadcast Address Adding the transmission place.
VPL-VW100
6
Download from Www.Somanuals.com. All Manuals Search And Download.
3-2. PJ Talk
The remote control service is provided that can control the projector from remote location via network.
3-2-1. Function
This responds to the control command and requests for acquiring the status and information supplied
from clients.
Control request
Enables the input to be selected and picture control to be adjusted.
SIRCS request
Enables remote control by sending the SIRCS code.
Status request
Enables equipment status information such as power status, error information and power-on time to be
acquired.
Information request
Enables equipment information such as equipment name, serial number and installation information to be
acquired.
Protocol
Item
Description
Protocol name
Transport
SDCP (Simple Display Control Protocol)
TCP
Port number
53484 (Factory-shipments value)
30 seconds (Factory-shipments value)
TCP connection timeout
3-2-2. Setup Items
The items that can be set for the PJ Talk service are described below.
Setup item
Description
Port No.
Port number
Timeout
TCP connection timeout time
IP address of connectable PC
Host Address
VPL-VW100
7
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3. SDAP Protocol
This section describes the SDAP packet structure.
Power
Status
(2)
Header Community
Product name
(12)
Serial No.
(4)
Location
(24)
(4)
(4)
Fig.1 Packet structure
1) Header
The header consists of ID (16 bit), version (8 bit) and category (8 bits).
(Bit position)
0
0
1
0
2
0
3
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
“DA” (16)
Version (8)
Category (8)
Fig. 2 Header
ID
It is fixed to “DA”.
Version
This indicates the version number of protocol.
It is fixed to 01h (version 1).
Category
Category number 0Ah of the projector is entered here.
2) Community (Refer to 3-4-1-2.)
The community that is set in the display equipment is entered.
(Bit position)
0
0
1
0
2
0
3
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
Community (32)
Fig. 3 Community
3) Equipment Information
Product Name
Name of equipment (Maximum twelve characters)
In case, less than twelve characters, 00h is entered in the blank space.
Serial No.
Serial number is entered.
Power Status.
Power supply status of the equipment is entered.
Location
Information of installation location (Maximum twenty four characters)
In case, less than twenty four characters, 00h is entered in the blank space.
VPL-VW100
8
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4. SDCP Protocol
This section describes the packet structure of version 2.
Header Community
(2) (4)
Command
(4)
Data (n)
Fig. 1 Packet structure
3-4-1. Format
3-4-1-1. Header
The header consists of version (8 bits) and category (8 bits).
0
0
1
0
(Bit position)
1
2
3
4
5
6
7
8
9
1
2
3
4
5
Version (8)
Category (8)
Fig. 2 Header structure
Version
This indicates the version number of protocol.
It is fixed to 02h (version 2).
Category
Category number 0Ah of the projector is entered here. Projector checks the category number. If a differ-
ent category number is entered, the request is ignored.
3-4-1-2. Community
When the community data matches the community that is set in the display equipment, the request is
executed. Community consists of four alphanumeric characters (case sensitive). All display equipment
has the default value “SONY” when shipped from the factory.
(Bit position)
0
0
1
0
2
0
3
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
Community (32)
n
Community should be entered with four characters. Three characters or less are not accepted.
VPL-VW100
9
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-1-3. Command
This section describes the format of the request command and the response command.
(Bit position)
0
0
1
0
2
0
3
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
Request/Response (8)
Request/Response (8)
Item No (16)
Item No (16)
Data Length (8)
Data Length (8)
(1) Request
This section describes the format of the request command that is issued from the host PC to the projector.
Community
This is the same alphanumeric characters as those of community that is set in the projector to which
request is going to be sent.
Request
There are only two types of request. One is the GET request to acquire the projector information and
status. The other is the SET request to modify the projector setup.
Request Contents
SET (00h) Used to control turning the power on/off and to control the input selector, and to change the various setups.
GET (01h) Used to acquire the installation information, equipment status and various setup values.
Item No.
This is the item number of the request target.
Data Length
This is the length of the data accompanying the request. The maximum length is 128 bytes. If there is no
data, it is 0.
Data
This is the data accompanying the request.
(2) Response
This section describes the format of the response command which is used to return a response to the host
PC from the projector.
Community
The same alphanumeric characters as those of the request is entered.
Response
The response returns the result of executing the request from the host PC.
Response
Contents
NG (00h)
OK (01h)
Indicates that the request is illegal or cannot be executed.
Indicates that the request was executed correctly.
Item No.
The same value as those of the request is entered.
Data Length
This is the length of the data accompanying the response. The maximum length is 128 bytes. If there is no
data, it is 0.
Data
This is the data accompanying the response.
VPL-VW100
10
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-1-4. SET Request
The SET request is used to set a new value in the specified item. Details of the request and the response
are described below.
Request
Data
Length
Data
Set Data (n byte)
Item No.
Item No.
Request
SET (00h)
n
Response
OK (01h)
Item No.
0
3-4-1-5. GET Request
The GET request is used to acquire the value of the specified item. Details of the request and the response
are described below.
Request
Data
Length
Item No.
Item No.
Request
GET (01h)
0
Response
OK (01h)
Item No.
n
Get Data (n byte)
3-4-1-6. ERROR Response
When an error occurs in the contents of a request or in the result of execution, NG is returned as the
response.
NG (00h)
Item No.
2
Error Code (16)
VPL-VW100
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-2. Items
Category
Contents
SET
GET
O
00**h
01**h
03**h
17**h
19**h
80**h
90**h
Used to control and to change the various setups.
Used to acquire the status.
O
O
Used to reset memory.
O
O
O
Sircs (15 bit category)
Sircs (20 bit category)
Used to acquire equipment information.
Used to acquire network setup information.
O
O
3-4-2-1. Model Dependent Category
The supported contents of 00**h, 01**h, 03**h, 17**h and 19**h change depending on the model.
Details are shown on Appendix.
3-4-2-2. Equipment Information Acquisition (80**h)
Used to acquire the equipment information.
Lower byte
Contents
SET
GET
00h
01h
02h
03h
Category Code
Model name
O
O
O
O
Serial number
Installation location
O
0x8000 Category code
1 byte
0x8001 Model name
Alphanumeric 12 characters
If the number of characters is less than 12, the remaining digits are filled with 00h.
0x8002 Serial number
4 bytes
n
The serial number is in the range of 00000000 to 99999999.
0x8003 Installation location
Alphanumeric 24 characters
If the number of characters is less than 24, the remaining digits are filled with 00h.
VPL-VW100
12
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-2-3. Network Information Acquisition (90**h)
Used to acquire the network setup information.
Lower bytes
Contents
SET
GET
00h
01h
02h
03h
04h
MAC Address
IP Address
O
O
O
O
O
Subnet Mask
Default Gateway
DHCP
0x9000 Mac Address
6 bytes
0x9001 IP Address
4 bytes
0x9002 Subnet Mask
4 bytes
0x9003 Default Mask
4 bytes
0x9004 DHCP
1 byte
DHCP invalid: 0
DHCP valid: 1
VPL-VW100
13
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-3. Error Code
The error code list is shown below with a detailed description of each.
Category
Error
Error Code
Item Error (01**h)
Invalid Item
01h
02h
03h
04h
11h
80h
01h
01h
02h
03h
11h
12h
13h
01h
01h
10h
20h
30h
40h
50h
F0h
10h
20h
Invalid Item Request
Invalid Length
Invalid Data
Short Data
Not Applicable Item
Different Community
Invalid Version
Invalid Category
Invalid Request
Short Header
Short Community
Short Command
Timeout
Community Error (02**h)
Request Error (10**h)
Network Error (20**h)
Comm Error (F0**h)
Timeout
Check Sum Error
Framing Error
Parity Error
Over Run Error
Other Comm Error
Unknown Response
Read Error
NVRAM Error (F1**h)
Write Error
VPL-VW100
14
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-3-1. Item Error
This error occurs when the Item No. of a request is illegal or its data is illegal. The conditions for occur-
rence of the respective errors are shown below.
Invalid Item
An unsupported Item No. is specified.
Example 1: The unsupported category 0xA** is specified.
Example 2: The unsupported Item No. 0x8010 is specified.
Invalid Item Request
The Item No. is supported but an unsupported Request is issued.
Example: An attempt is made to set data in the Model Name (0x8001).
Invalid Length
Data length of the specified Item No. is too long.
Example: An attempt is made to set 25 byte data in the installation location (0x8003).
Invalid Data
Data of the specified Item No. is outside the setting range.
Example: An attempt is made to set 101 in the Item when the setting range of the Item is 1 to 100.
Short Data
The length of data is shorter than the value specified by the data length.
Example: The actual data length is 9 bytes but data length is 10.
Not Applicable Item
An item that is not valid at present is specified.
Example: The item to switch the display is specified when the main power is off.
3-4-3-2. Community Error
This error occurs when community is different.
Example: “ABCD” is specified when “SONY” is set.
VPL-VW100
15
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-3-3. Request Error
This error occurs when header or command is illegal. The conditions of occurrence of the respective
errors are shown below.
Invalid Version
The version of the header is other than 2.
n
When another version is supported, an error occurs in all versions other than the supported version.
Invalid Category
The category does not match.
Example: 0x0B is specified in the device of category = 0x0A.
Invalid Request
An unsupported request is specified.
Example: Request = 0x02 is specified.
Short Header
The received data is 1 byte.
Short Community
The received data is in the range of 2 to 5 bytes.
Short Command
The received data is in the range of 6 to 9 bytes.
3-4-3-4. Network Error
This is an error that occurs in TCP/IP. The conditions of occurrence of the respective errors are shown
below.
Timeout
Communication was interrupted.
VPL-VW100
16
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4-3-5. Comm Error
This is an error in communication with the main control microprocessor of the display.
Timeout
Reception data is not returned after data is sent.
Check Sum Error
A check sum error occurred in the main control microprocessor of the display.
Framing Error
A framing error occurred.
Parity Error
A parity error occurred.
Over Run Error
An overrun error occurred.
Other Comm Error
Another error occurred.
Unknown Response
The data cannot be processed was received.
3-4-3-6. NVRAM Error
Read Error
Reading from NVRAM was failed.
Write Error
Writing to NVRAM was failed.
VPL-VW100
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
<Table 1>
Item Number
Upper byte
00h
<Table 2>
Data
Upper byte
00h
Remarks
Item
Lower byte
Data
Lower byte
00h
Input
01h
Video
Set/Get
S Video
00h
01h
Input-A
00h
02h
Component
00h
03h
HDMI
00h
04h
DVI
00h
05h
Picture Mode
00h
02h
Dynamic
00h
00h
Standard
00h
01h
Cinema
00h
02h
User1
00h
03h
User2
00h
04h
User3
00h
05h
Contrast
Brightness
Color
00h
00h
00h
00h
00h
00h
10h
11h
12h
13h
14h
17h
Setting value (0 to 100)
00h
00h to 64h
00h to 64h
00h to 64h
00h to 64h
00h to 64h
00h
Setting value (0 to 100)
00h
Setting value (0 to 100)
00h
Hue
Setting value (0 to 100)
00h
Sharpness
Col Temp
Setting value (0 to 100)
00h
High
Mid
00h
00h
01h
Low
00h
02h
Custom1
Custom2
Custom3
Off
00h
03h
00h
04h
00h
05h
DRC MODE
Black Level Adj.
Advanced Iris
00h
00h
00h
00h
1Bh
1Ch
1Dh
1Eh
00h
00h
Mode1
Mode2
Off
00h
01h
00h
02h
00h
00h
Low
00h
01h
High
00h
02h
Off
00h
00h
On
00h
01h
Auto
00h
02h
RCP
Off
00h
00h
(Real Color Processing)
User1
User2
User3
Auto
00h
01h
00h
02h
00h
03h
Film Mode
00h
1Fh
00h
00h
Off
00h
01h
VPL-VW100
18
Download from Www.Somanuals.com. All Manuals Search And Download.
<Table 1>
Item Number
Upper byte
00h
<Table 2>
Data
Upper byte
00h
Remarks
Item
Lower byte
Data
Lower byte
00h
01h
02h
03h
04h
00h
01h
02h
03h
00h
01h
00h
01h
00h
01h
02h
03h
00h
01h
00h
01h
02h
03h
00h
01h
03h
00h
01h
Wide Mode
20h
Full
Normal
Set/Get
00h
Wide Zoom
Zoom
00h
00h
Subtitle
00h
Gamma Correction
00h
22h
Off
00h
Gamma 1
00h
Gamma 2
00h
Gamma 3
00h
OverScan
Screen Area
NR
00h
00h
00h
23h
24h
25h
Off
00h
On
00h
Full
00h
Through
00h
Off
00h
Low
00h
Middle
00h
High
00h
PictureMuting
00h
00h
30h
32h
Off
00h
On
00h
Input-A Signal Sel
Auto
00h
Computer
00h
Component
Video GBR
Auto
00h
00h
DVI Signal Sel
Color Space
00h
00h
33h
3Bh
00h
Computer
00h
Video GBR
Normal
00h
00h
Wide
00h
USER GAIN RED
USER GAIN GREEN
USER GAIN BLUE
USER BIAS RED
USER BIAS GREEN
USER BIAS BLUE
GAIN RED
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
50h
51h
52h
53h
54h
55h
80h
81h
82h
83h
84h
85h
Setting value (_30 to 30)
Setting value (_30 to 30)
Setting value (_30 to 30)
Setting value (_30 to 30)
Setting value (_30 to 30)
Setting value (_30 to 30)
Setting value (0 to 255)
Setting value (0 to 255)
Setting value (0 to 255)
Setting value (0 to 255)
Setting value (0 to 255)
Setting value (0 to 255)
E2h to 1Eh (–30 to 30)
E2h to 1Eh (–30 to 30)
E2h to 1Eh (–30 to 30)
E2h to 1Eh (–30 to 30)
E2h to 1Eh (–30 to 30)
E2h to 1Eh (–30 to 30)
00h
00h
00h
00h
00h
00h
00h to FFh
GAIN GREEN
00h to FFh
00h to FFh
00h to FFh
00h to FFh
00h to FFh
GAIN BLUE
BIAS RED
BIAS GREEN
BIAS BLUE
VPL-VW100
19
Download from Www.Somanuals.com. All Manuals Search And Download.
<Table 1>
Item Number
Upper byte
01h
<Table 2>
Data
Upper byte
00h
Remarks
Item
Lower byte
Data
No Error
Lower byte
00h
Status Error
01h
Get only
Lamp Error
00h
01h
Fan Error
00h
02h
Cover Error
Temp Error
00h
04h
00h
08h
D5V Error
00h
10h
Power Error
Temp Warning Error
NVM Data Error
Stanby
00h
20h
00h
40h
00h
80h
Status Power
01h
02h
00h
00h
Start Up
00h
01h
Start Up Lamp
Power On
00h
02h
00h
03h
Cooling1
00h
04h
Cooling2
00h
05h
Saving Cooling1
Saving Cooling2
Saving Stanby
User Mode
00h
06h
00h
07h
00h
08h
Control Mode
01h
05h
00h
00h
Service Mode
Lamp Use Time
MAIN ROM Version
SC ROM Version
NVM data VERSION
_
00h
01h
Lamp Timer
ROM Version
01h
01h
01h
01h
03h
13h
0000h-FFFFh *1
1Dh
*2
*2
*3
SC ROM Version
NVM Data VERSION
W/B All Save
1Eh
27h
04h
00h
00h
Set only
W/B Low Save
05h
W/B High Save
06h
07h
W/B Middle Save
W/B Custom1 Save
W/B Custom2 Save
W/B Custom3 Save
Sircs(15 bit category)
Sircs(20 bit category)
08h
09h
0Ah
17h
19h
Refer to Table4
Refer to Table5
_
_
00h
00h
00h
00h
Set only *4
*1 Example) In case the lamp timer indicates 1000H, return values are [03h] upper byte and [E8h] lower byte.
*2 Example) In case the software version is 1.03, return values are [01h] upper byte and [03h] lower byte.
*3 Example) In case the NVM data version is 3, return values are [00] upper byte and [03] lower byte.
*4 It is corresponded to single command only.
VPL-VW100
20
Download from Www.Somanuals.com. All Manuals Search And Download.
<Table 3>
Item Number
Data
Item
ACK
NAK
Data
Upper byte
Lower byte
00h
_
00h
01h
Undefined Command
Size Error
01h
04h
Select Error
05h
Range Over
06h
Not Applicable
Check Sum Error
Framing Error
Parity Error
0Ah
F0h
10h
20h
30h
Over Rub Error
Other Comm Error
40h
50h
Waiting time for the return value is about 200 msec.
n
This waiting time for the return value is subject to the conditions that commu-
nication is not bothered by any reasons.
VPL-VW100
21
Download from Www.Somanuals.com. All Manuals Search And Download.
List of SIRCS CODE
<15BIT CATEGORY>
<Table 4>
x0
x1
x2
x3
x4
x5
x6
x7
x8
x9
xA
xB
xC
xD
xE
xF
0x
1x
2x
3x
4x
5x
6x
7x
POWER
ON/OF
*1
CONTRAST+ CONTRAST-
COLOR+
HIGH
COLOR-
LOW
BRITNESS+
BRIGHT
BRITNESS-
DARK
HIGH
LOW
POWER
ON
*1
HUE+
PURPLISH
HUE-
GREENISH
SHARPNESS+ SHARPNESS-
PICTURE
MUTING
STATUS
ON
STATUS
OFF
POWER
OFF
MENU
VIDEO
INPUT A
COMPONENT
SHARP
SOFT
CURSOR
→
CURSOR
←
CURSOR
↑
CURSOR
↓
ADJ R
ADJ G
ADJ B
SIZE
SHIFT
W/B
GAIN
W/B
BIAS
INPUT
SELECT
ENTER
MEMORY
S VIDEO
HDMI
LENS
LENS
LENS
FOCUS F
LENS
FOCUS N
LENS
ZOOM L
LENS
ZOOM S
DVI
RESET
↑
↓
SHIFT
SHIFT
*1. When the Standby mode is set to [Low], the projector enters the Power-Saving mode in about 1 minute after Standby. If any command is sent during the Standby mode,
“Not Applicable” is returned. However, if the same command is sent again, the command will be executed.
<20BIT CATEGORY>
<Table 5>
x0
x1
x2
x3
x4
x5
x6
x7
x8
x9
xA
xB
xC
xD
xE
xF
ADJUST
PICTURE
TOGGLE
0x
1x
2x
3x
4x
5x
6x
7x
RCP
V
KEYSTONE
DRC MODE
TOGGLE
PICTURE
MODE
DYNAMIC
PICTURE
MODE
STANDARD
PICTURE
MODE
CINEMA
PICTURE
MODE
USER1
PICTURE
MODE
USER2
PICTURE
MODE
USER3
PICTURE
MODE TGL
DOT
PHASE
LENS
ZOOM
LENS
SHIFT
LENS
FOCUS
WIDE MODE
TOGGLE
LENS CONT
TOGGLE
Download from Www.Somanuals.com. All Manuals Search And Download.
The material contained in this manual consists of
information that is the property of Sony Corporation.
Sony Corporation expressly prohibits the duplication of
any portion of this manual or the use thereof for any
purpose other than the operation or maintenance of the
equipment described in this manual without the express
written permission of Sony Corporation.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Corporation.
Sony Corporation interdit formellement la copie de
quelque partie que ce soit de ce manuel ou son emploi
pour tout autre but que des opérations ou entretiens de
l’équipement à moins d’une permission écrite de Sony
Corporation.
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als
die Bedienung oder Wartung der in dieser Anleitung
beschriebenen
Ausrüstung
ohne
ausdrückliche
schriftliche Erlaubnis der Sony Corporation.
VPL-VW100
Download from Www.Somanuals.com. All Manuals Search And Download.
English
2005LR16-1
©2005
Sony EMCS Corporation
VPL-VW100 (SY) E
9-872-775-01
Ichinomiya Tec
Download from Www.Somanuals.com. All Manuals Search And Download.
|