1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES  
UNPACKING  
Check Packaging - Upon taking delivery of the unit, inspect the packaging for signs of damage. If damage has  
occurred, advise the carriers and/or the suppliers immediately.  
Check Contents - Upon taking delivery of the unit, unpack the unit carefully and check that all the items are  
present and correct. If any items are missing or damaged, contact your equipment dealer.  
Retain Packaging - The shipping carton is the safest container in which to transport the unit. Retain  
undamaged packaging for possible future use.  
IMPORTANT SAFETY PRECAUTIONS  
Read Instructions - All relevant safety, installation and operating instructions should be read before attempting  
to install, connect or operate the unit.  
Retain Instructions - All safety, installation and operating instructions should be retained for future reference.  
Heed Warnings - All warnings on the unit and in any relevant safety, installation or operating instructions  
should be adhered to.  
Cleaning - Unplug the unit from the power outlet before cleaning. Do not use liquid cleaners or aerosol  
cleaners. Use a damp cloth for cleaning.  
Attachments - Do not use attachments not recommended by the product manufacturer as they may cause  
hazards.  
Water and Moisture - Do not expose the internal electronics of this unit to water or dampness; for example, in  
an unprotected outdoor installation, or in any area classified as a wet location. The unit as supplied conforms to  
ingress protection rating IP 67. This rating will be affected by any holes made in the enclosure. Cable entry  
points should be protected by the use of suitably rated glands and/or flexible conduit. It is not necessary to  
make further holes in the enclosure for mounting purposes, as mounting holes are provided at the corners of the  
enclosure outboard of the seal between enclosure and lid.  
Accessories - Do not attach this unit to an unstable stand, bracket or mount. The unit may fall, causing serious  
injury to a person and serious damage to the unit.  
Power Sources - This unit should be operated only from the type of power source indicated on the  
manufacturer’s label. If you are not sure of the type of power supply you intend to use, consult your equipment  
dealer or local power company. For units intended to operate from battery power or other sources, refer to  
operating instructions.  
Power Connector - This unit is equipped with coaxial power connector mounted at the edge of the PCB for low  
voltage power input. Do not attempt to alter this connector in any way.  
Power Cord Protection - Power supply cords should be routed so that they are not likely to be trapped, pinched  
or otherwise damaged by items in close proximity to them, whether inside the unit or outside it. Particular  
attention should be paid to cords at plugs, connection units and the point of exit from the unit.  
Overloading - Do not overload outlets and extension cords, as this can result in fire or electric shock.  
Object and Liquid Entry - Never push objects of any kind into the unit, as they may touch dangerous voltage  
points or short out parts that could result in fire or electric shock. Never spill liquid of any kind on or inside the  
unit.  
Servicing - Servicing of the unit should only be undertaken by qualified service personnel, as opening or  
removing covers may expose you to dangerous voltages or other hazards.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Damage Requiring Service - Servicing by qualified personnel should be carried out under the following  
conditions:  
(a)  
(b)  
(c)  
(d)  
When the power-supply cord or plug is damaged.  
If liquid has been spilled or objects have fallen into the unit  
If the internal electronics of the unit have been exposed to rain or water  
If the unit does not operate normally by following the operating instructions. Adjust only those  
controls that are covered by the operating instructions, as improper adjustment of other controls may  
result in damage and will often require extensive work by a qualified technician to restore the unit to  
normal operation.  
(e)  
(f)  
If the unit has been dropped or the enclosure is damaged.  
If the unit exhibits a distinct change in performance. This indicates a need for service.  
Replacement Parts - If replacement parts are required, ensure that only replacement parts recommended by the  
product manufacturer are used.  
Safety Check - Upon completion of any service or repairs to the unit, safety checks should be performed to  
ensure that the unit is in proper operating condition.  
Pre-installation Checks - It is recommended that the unit be bench-tested prior to installation on the site.  
Safety During Installation or Servicing - Particular care should be taken to isolate the dome in order to prevent  
operation while engineering work is being carried out on the Rx100.  
Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the Health  
and Safety at Work Act should be observed.  
WARNING  
TO PREVENT DANGER OF FIRE OR SHOCK, DO NOT EXPOSE THE INTERNAL COMPONENTS OF THIS  
EQUIPMENT TO RAIN OR MOISTURE.  
The “lightning flash with arrowhead” symbol inside an equilateral triangle is used to warn the user of this  
equipment that there are sufficiently high voltages within the enclosure to constitute a risk of electric shock.  
The “exclamation point” symbol inside an equilateral triangle is used to alert the user of this equipment to  
important operating and maintenance (servicing) instructions in the literature accompanying the appliance.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. INTRODUCTION  
GENERAL  
The Rx100 telemetry interface is designed to allow control of a variety of integrated dome cameras using BBV’s  
range of up-the-coax telemetry transmitters. See appendix A for a complete list of supported domes.  
The Rx100 interface is supplied in an IP67 rated enclosure. It will be necessary to make suitable holes in the  
enclosure to permit cable entry and exit. Adequately rated cable glands and or flexible conduit should be used at  
all times to avoid compromising the protection afforded by the enclosure as supplied. Any holes made in the  
enclosure for any other purpose should be sealed with a non-hardening waterproof sealant, taking care to ensure  
that the internal electronics are not contaminated.  
Rx100 TECHNICAL SPECIFICATION  
Power Requirements:  
Current Consumption:  
Features:  
RX100 9-12V ac/dc – plug mounted PSU provided  
RX100/24 – 24Vac or 230Vac  
RX100 - 100mA @ 12Vdc maximum  
RX100/24 – 630mA @ 230Vac maximum  
Serial data output 2 wire RS485/RS422.  
4 alarm inputs.  
1 N/C alarm output.  
Up to 16 pre-set positions can be stored within the Rx100.  
Relay capable of switching 1Kw of lighting.  
Engineering Facilities:  
Telemetry Signals:  
Unit auto-tunes to the coaxial telemetry signal.  
LED readout for continual system status.  
Video launch amplifier provided with Gain and Lift controls.  
Colour-coded cage clamp terminals. Mains terminal connections:  
Live, Neutral and Earth and Low Voltage.  
Telemetry signals either:  
up-the-coax (max distances, 250M of RG59 or 500M of CT125/RG11).  
or twisted pair 0-20mA current loop.  
Video Input:  
1v p-p 75terminated input via BNC socket.  
Video Output:  
1v p-p to 4v p-p 75impedance via BNC socket.  
Up to 16 full-scene preset positions can be stored within the interface depending upon the model of dome.  
Dimensions (external): RX100/WBX  
RX100/24/WBX  
Width: 190 mm Width: 190mm  
Length: 280 mm Length: 380mm  
Height: 130 mm Height: 130mm  
Weight:  
1.0Kg  
3.6Kg  
Temperature range:  
-10° Celsius to +40° Celsius  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRANSMITTER COMPATABILITY CHART  
Tx300  
2 Speeds 2 Speeds  
Tx400  
Tx400DC  
Proportional  
Joystick  
Tx1000  
2 Speeds  
Tx1000DC  
Proportional  
Joystick  
Tx1500  
Proportional  
Joystick  
Variable  
Speed  
Fixed Speed  
9
9
9
9
-
-
9
-
9
9
9
9
8
9
9
9
9
8
9
9
9
9
16  
2
9
9
9
9
9
9
9
16  
2
9
9
9
9
9
9
9
16  
2
9
9
9
Zoom  
Focus  
Iris  
Pre-sets  
Patrols  
Lights  
Autopan  
2
2
9
9
9
9
9
9
Camera  
Functions  
-
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CABLE CONNECTION METHOD  
Fig. 1: cage clamp connectors  
The cage clamp PCB terminal block is a simple-to-use method of  
attaching cables to PCBs quickly and easily. Prepare cables as  
follows:  
Use only cable between 0.08 and 2.5 mm²  
Strip the cable to a length of 5 to 6 mm (0.23 in)  
The correct method of attachment is as follows:  
1. Press down the relevant terminal block lever with a suitable  
screwdriver;  
2. Insert wire;  
3. Remove screwdriver.  
The procedure for detaching wires is the reverse of the 3 attachment  
steps, ensuring that power is disconnected before starting.  
CABLING RECOMMENDATIONS FOR THE Rx100 INTERFACE.  
Although BBV do not specify any particular type, manufacturer or supplier of cables, the following ESD  
Electronic Services (01279 626777) cables have been used successfully for production and testing:  
ESD Part Number:  
Description:  
0222586G  
(100 m)  
Coax Cable (Minimum Specification)  
RG59B/U ESD radio frequency coax cable to BS2316 and MIL-C-17  
1/0.58mm copper-covered steel wire conductor with solid polythene dielectric, bare  
copper wire braid and PVC sheath  
Characteristic impedance: 75 Ohm  
Capacitance: 22pF/ft  
020966D  
(100 m)  
Orange-Coloured Lighting Output Power Cable (1000 w)  
3183Y PVC-insulated, 3-core cable  
1.25mm² 40/0.2mm annealed copper conductor  
Current rating: 13 amp  
0140467H  
(100 m)  
20mA Twisted Pair Cable (Minimum Specification)  
British Telecom spec CW 1308  
2-core 1/0.5mm PVC-insulated  
Maximum conductor resistance at 20 degrees Celsius: 97.8 ohms/km  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. INSTALLATION  
OPERATING VOLTAGE  
The Rx100 requires all connections to the PCB to be made by the installer, and via terminal blocks or by plug  
and socket. These connections are: power in, video in, video out, and serial data to dome. In addition  
connections for alarm in, alarm out and lights if required are provided. See fig.2 below for correct connections.  
The Rx100 is supplied pre-configured to suit the application for which it is intended, i.e. to control an integrated  
dome camera.  
IMPORTANT NOTE – If link J6/4-5 is removed it must be refitted to J6/3-4 position or the RX100 will  
assume it is still fitted.  
Fig. 2 Rx100 Iss6 PCB connections  
J6 OPTION LINKS HF Lift  
Gain  
J6/1-2  
J6/4-5  
POWER 9 - 12 V AC/DC  
LIFT  
GAIN  
100mA MAX  
J4  
CAMERA  
5
1
9-12V  
supply  
CABLE  
Video In  
from dome  
ERROR  
AC  
J3  
AC  
Twisted Pair IN from  
telem transmitter  
RS485 OUT to dome  
TP  
TP  
GND  
C1  
C2  
J3  
Video Out  
to transmitter  
C3  
C4  
GND  
AOUT  
AOUT  
GND  
GND  
A1  
A2  
A3  
A4  
N/C Alarm  
OUT  
N/C  
Alarm  
contacts IN  
Test  
TELEMETRY  
J5  
Lights Supply  
Neutral  
Earth  
Live  
RY1  
J7  
J1  
4
Amp 250V MAX  
pcb 97002 Iss 6  
BBV  
Lights  
Feed  
RS485 to Panasonic domes  
Test Link  
Function  
Power In  
or  
Video In  
Video Out  
Connector  
J4  
J3/AC-AC  
CAMERA  
TELEMETRY  
Type  
2.1mm coaxial  
Grey WAGO  
BNC SOCKET  
BNC SOCKET  
Twisted Pair Telemetry J3/TP-TP  
Grey WAGO  
Serial to dome  
or  
J3/C1-C4-GND  
J7  
Grey WAGO  
FCC68  
(Fitted for Panasonic versions)  
Alarm 1 contact in  
Alarm 2 contact in  
Alarm 3 contact in  
Alarm 4 contact in  
Alarm contact out  
J3/A1-GND  
J3/A2-GND  
J3/A3-GND  
J3/A4-GND  
J3/AOUT-AOUT  
Grey WAGO  
Grey WAGO  
Grey WAGO  
Grey WAGO  
Grey WAGO  
(optional if alarm input required)  
(optional if alarm input required)  
(optional if alarm input required)  
(optional if alarm input required)  
(optional if alarm input required)  
Lighting relay  
J5  
Coloured WAGO (optional if lights control required)  
(clean contact between orange connectors)  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. SETUP  
DIAGNOSTIC AIDS  
Two red LEDs and one Green LED are mounted on-board to give simple system status information. Their  
functions are as follows:  
Cable LED  
Regular Blinking  
-
Telemetry and video signals are OK.  
Blinking but mainly ON  
Blinking but mainly OFF  
-
-
No Telemetry from the transmitter.  
No video from the camera.  
Error LED  
On  
-
-
Telemetry transmission error.  
No power or major PCB fault.  
Both LEDs  
Off  
Data LED (Iss PCB 4 onwards only)  
-
Will flash on and off very fast when data  
is  
being sent to the dome.  
Test Link  
-
Is used to confirm correct operation of the  
Rx100 and dome and also that the RS485  
connection is correct. Shorting the link after the  
Rx100 is powered up will cause the dome to pan  
left and zoom in. Removing the link will stop the  
pan left and will zoom out the lens. This is  
dependant on dome type.  
All BBV equipment is designed to auto-tune and compensate for any discrepancies in the transmitted telemetry  
signal; there are no further adjustments that need to be made.  
VIDEO LAUNCH AMPLIFIER AND CABLE LENGTH COMPENSATION  
The interface features a video launch amplifier with two variable controls situated close to the BNC connectors:  
Lift and Gain. These are pre-adjusted for a cable distance of 500m of CT125, and are adjustable to compensate  
for video detail or signal losses if and when longer or shorter cable lengths are used to connect the telemetry  
transmitter to the interface.  
Fig. 3 Launch Amplifier  
HF Lift  
Gain  
The purpose of each control is:  
Video  
from  
CAMERA  
LIFT  
dome  
GAIN varies the overall signal level.  
GAIN  
Video  
to  
transmitter  
LIFT boosts the high frequency component of the video  
signal. If the high frequency component is too low, picture  
appears ‘washed out’ and lacking detail.  
TELEMETRY  
Default position adjusted for 500M of CT125.  
For shorter cable lengths, turn the Gain control anti-clockwise until 1V p-p is present at the telemetry  
transmitter. For longer cable lengths, turn the Gain control clockwise until 1V p-p is present at the telemetry  
transmitter.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. SYSTEM SCHEMATIC DIAGRAMS  
Rx400DC  
Rx45X AC  
Rx55X DC  
Rx400P  
Rx300  
Rx100  
Rx200  
High & Variable speed  
P/T Zoom/Focus  
BBV RS485  
AC Fixed Speed  
P/T Zoom/Focus  
32 Preset with 4 Aux.  
8 Local alarms  
BBV RS485  
High & Variable speed  
P/T Zoom/Focus  
AC P/T Zoom/Focus  
AC P/T Zoom/Focus  
1 Aux.  
dome camera  
4 local alarms  
static camera with  
lights/wash/wipe  
static camera  
16 Presets with 4 Aux.  
16 Preset with 3 Aux.  
8 Local alarms  
STATIC  
32 Preset with 3 Aux.  
8 Local alarms  
video & data  
Dome library includes:  
Alltec Apollo  
Chugai/Computar SMD  
Dennard type 2050  
Ulltrak/Diamond KD6  
Dynacolor  
Forward Vision MIC  
*JVC TK-C675/675B  
Kalatel Cyberdome  
(1/1/02 or later)  
Up-the-coax telemetry  
250M RG59 / 500M CT125  
video in - coax  
RS485 twisted pair  
Kenko Daiwa DMP15H1  
Kenko Daiwa DMP16H3  
MarkMercer D250MPT  
Merit Li-Lin PIH717X  
Panasonic WV-CSR400  
Panasonic WV-CSR600  
Panasonic WV-CSR650  
Panasonic WV-CS850  
Pelco SD5 'Spectra'  
*Philips G3 (RS232)  
Sanyo VCC9200P  
Sensormatic Speed dome  
Sony EVI-31D  
RS485 StarCard  
8 outputs  
RS485 twisted pair  
TX1500/16/8/16AL Matrix  
Monitor 1-4 with OSD  
Monitor 5-8 without OSD  
Cat5 RJ45 patch cable  
Star MD100 & MD200  
VCL TP domes  
*Vicon Surveyor 2000  
Videcon dome  
Vista PowerDome  
RJ45 Breakout  
Box  
twin UTP  
twin UTP  
*Rx100/24 230Vac  
powered with 24Vac 100VA  
output.  
B-BUS multidrop 4 wire RS422  
Supplied 2M CAT5 cable  
Poweres 1st keyboard.  
RJ45 Breakout  
Box  
RJ45 Breakout  
Call BBV for info.  
Box  
Use RJ45 breakout boxes if > 2M  
Cat5 RJ45 patch cable  
Cat5 RJ45 patch cable  
TX1500/KBD  
Expandable up to 96 cameras inputs. 4 control positions including remote control via RS232/485 interface unit.  
Up to 96 alarm inputs using 16 input alarm modules. BBV up-the-coax and RS485 telemetry as standard.  
The STARCARD/CONVETER allows RS485 control of domes etc.  
Fig.4  
Simple control protocol to allow integration with 3rd part equipment.  
TX1500/KBD  
TX1500/KBD  
SYSTEM SCHEMATIC SHOWING INTEGRATION OF DOME INTO Tx1500 SYSTEM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig.5  
SYSTEM SCHEMATIC SHOWING INTEGRATION OF DOME INTO Tx1000 SYSTEM.  
Rx400DC  
High & Variable speed  
P/T Zoom/Focus  
16 Preset with 3 Aux.  
8 Local alarms  
Rx300M  
Rx200  
Rx100  
Rx400P  
AC P/T Zoom/Focus  
16 Presets with 3 Aux.  
AC P/T Mitsubishi  
CCD400 control  
2 Aux.  
Rx300  
AC P/T Zoom/Focus  
1 Aux.  
static camera with lights/  
wash/wipe  
Rx200  
simple AC panner  
dome camera  
4 local alarms  
static camera  
STATIC  
up-the-coax telemetry 250M-RG59, 500M-CT125  
video in - coax  
Twisted Pair telemetry.  
Loop resistance < 300R  
Optional  
Twisted Pair  
alarm cable  
Optional Alarm Package  
Tx1000/8 or 16 Base Unit  
TxLD  
TxLD  
Twin Twisted Pair  
Optional TxLD link. Distance > 50M.  
video out - coax  
9V plug PSU  
RS232 control Max distance - 50M  
Optional TxLD available for extended  
distances.  
B
B
V
B
B
V
1000  
1000  
PROGRAM  
#
PROGRAM  
1
9
2
3
4
5
6
7
8
#
1
9
2
3
4
5
6
7
8
AUTOPAN  
AUTOPAN  
10  
11  
12  
13  
14  
15  
16  
10  
11  
12  
13  
14  
15  
16  
ZOO  
M
ZOO  
M
IRIS  
FOCUS  
IRIS  
FOCUS  
CAMERA  
SELECT  
CAMERA  
SELECT  
SEQ  
PATROL  
PRESET  
MONITOR  
SEQ  
PATROL  
PRESET  
MONITOR  
LEN  
S
PAN  
+
TILT  
LEN  
S
PAN  
+
TILT  
KEYBOARD 1  
OPTIONAL 2ND KEYBOARD  
Fig. 6 SIMPLE SINGLE CAMERA SYSTEM  
Video  
Data  
Alarm  
contact  
250M-RG59  
500M-CT125  
Rx100 Interface  
B
1
B
V
400  
2
PROGRAM  
#
AUTOPAN  
9V  
PSU  
3
4
6
8
MONITOR  
IRIS  
FOCUS  
ZOOM  
5
7
PRESETS  
LENS  
PAN  
+
TILT  
Tx400DC  
9V  
PSU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A - Dome addendums & connection details  
Rx100/24  
iss. 4 pcb  
13  
14  
15  
31  
16  
36  
17  
18  
14  
19  
20  
21  
22  
23  
24  
25  
26/27  
28  
31  
29  
30  
31  
32  
33  
34  
35  
36  
37  
360 Vision VisionDome  
Borsatec BT2790FF Dome  
Chugai SMD-08ll, SMD-12, SMD-12ll, SMD-20  
Dennard 2050  
Diamond-Smartscan  
Dynacolor 7720  
Forward Vision MIC1300  
Gardiner Security Juno  
JVC TK-C675E / TK-C675BE  
Kalatel Cyberdome (1/1/2002 or later firmware)  
Li-Lin PIH-717X/7000/7600/7625  
Mark Mercer D250MPT  
Panasonic WV-CSR400, WV-CSR600. WV-CSR650  
Panasonic WV-CS850  
Pelco Spectra dome & Esprit head (P protocol)  
Philips AutoDome (RS232/485)  
Samsung SCC-641  
Sanyo VCC-9200P  
Sensormatic speeddome (RS422 Only)  
Sony EVI-D31, 1000  
Star MD-800, MD-1200S, MD-1200H, MD-2000  
Ultrak KD6  
VCL-TP  
Vicon Surveyor  
Videcon Dome  
Videcon VCP451 Camara  
Vista PowerDome  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100/24 Supply Additional information (iss. 6 pcb)  
The RX100/24 can be powered from either 230Vac or 24Vac. The diagrams below shows the connections that  
should be made for each supply voltage. Please note that when powered from 24Vac the 230Vac terminals will be  
at mains voltages. To prevent the risk of shocks the fuse must be removed from the fuse holder and no connections  
made to L and N. The 24Vac supply must be fused with a 315mA to protect the supply wiring.  
Fig 9. RX100/24 iss. 6 pcb Connection details when operating from a 230Vac supply.  
Important!  
When  
operating the unit  
from 24Vac, the fuse  
230Vac Supply  
from  
the  
230Vac  
connector fuse holder  
must be removed. No  
connections must be  
made to this connector,  
as it will have 230Vac  
across the  
terminals.  
L
&
N
24Vac 100VA  
output to power dome  
Fig 10. RX100/24 iss. 6 pcb Connection details when operating from a 24Vac supply.  
24Vac  
Supply  
IMPORTANT! Remove fuse from fuseholder  
and make no connection as these terminals  
315mA Fuse  
!
will have 230Vac across L and N.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following domes:  
360 Vision VisionDome  
Gardiner Security Juno  
Rx100 software RX1_31V2  
Application Notes  
The RX 100 provide the following functionality when controlling the above mentioned domes  
Variable speed Pan/Tilt.  
Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out.  
16 Full scene presets.  
2 preset patrols.  
Slow preset tour. Started by pressing AUTOPAN (As patrol 1 but slow speed movement and 10 second dwell)  
5 minute datum/park driving to preset 1 or slow preset tour. Disabled by removing link J6/1-2  
Program up to 16 privacy zones  
Additional commands:  
AUTOPAN: Pressing the AUTOPAN key will run the domes preset tour at slow speed between the patrol 1 preset positions.  
Advanced Features  
180 degree pan flip  
Privacy SET (enable)  
Privacy CLEAR (disable)  
Reset dome parameters  
Tx400  
‘#’ 1  
‘#’ 2  
‘#’ 3  
‘#’ 4  
Tx1000  
'#' WASH  
'#' WIPE  
'#' AUTOPAN  
'#' LIGHTS  
Tx1500 DM DS/DS2/BX2 Mux  
1 ’#’  
2 ’#’  
3 ’#’  
4 ’#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
The dome and Rx100 are linked using RS485 for control and video for the camera signal.  
Rx100  
J3-C1  
J3-C2  
Description  
TX-/B  
TX+/A  
Dome connection  
D-  
D+  
Notes:  
The dome address must be set at 1 for all the cameras that are controlled using a Rx100. Check with the dome manual if you have any doubts.  
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.  
If the slow preset tour is running, start patrol 1 & 2 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, the  
tour will restart. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until the next manual pan command.  
A datum/park mode is offered that drives the dome to preset 1 following 5 minutes of inactivity. This can be disabled by removing the link fitted across J6/pin  
4 & 5. and refitting to J6/pin 3 & 4.  
Privacy zone programming.  
The keystrokes shown assume use of a TX1500. Use the keystroke shown above if using another controller.  
Programming a zone  
The Rx100 can be used to program 16 privacy zones. The same procedure that is used to program a preset position is used to program or clear a privacy zone.  
To instruct the Rx100 to program a privacy zone press 2# followed by program preset 1 – 16. The screen will then go blank showing that the privacy zone has  
been set.  
Clearing a zone  
To clear/delete a privacy zone press 3# followed by program preset 1 – 16. The relevant privacy zone will then be disabled and the dome will move to show the  
zone that has been disabled so that the zone can easily be re-enabled if disabled in error.  
J6 Links  
J6/1-2 fitted to enable the 5 minute datum mode. After 5 minutes of inactivity the dome will be driven to either preset 1 or a slow preset tour is started  
depending upon link J6/4-5. J6/4-5 fitted = goto preset 1,J6/3-4 = start slow preset tour.  
Intended for up-the-coax control.  
When using 20mA TP telemetry control maybe slightly sluggish.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following domes:  
Borsatec BT2790FF Dome  
Rx100 software RX1_B3V2  
Application Notes  
The RX100 provides the following functionality when controlling the above mentioned dome:  
Variable speed Pan/Tilt.  
16 Full scene presets.  
2 RX100 preset patrols.  
Pattern 1 learn and playback  
2 preset patrols.  
4 alarm inputs moving to preset 1 - 4  
Additional commands:  
Advanced Features  
Dome MENU  
(Preset 95)  
Tx400  
‘#’ 1  
Tx1000  
'#' WASH  
Tx1500  
1 ’#’  
DM DS/DS2/BX2 Mux  
*889 002 or *889 10 10 2  
Start Patten 1  
(Preset 81)  
B L C. On OFF  
(Preset 93)  
DAY NIGHT MODE  
(Preset 152)  
‘#’ 2  
‘#’ 3  
‘#’ 4  
'#' WIPE  
2 ’#’  
3 ’#’  
4 ‘#’  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
'#' AUTOPAN  
‘#’ LIGHTS  
AUTOPAN calls scan - goto preset 66  
LIGHTS operates the dome AUX 1 relay - goto preset 94  
WIPER Disabled  
WASH Disabled  
RS485 control of dome using the following connections:  
Rx100  
J3-C1 TX/RX- Data-  
J3-C2 TX/RX+ Data+  
Description  
Dome  
RX -  
RX+  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Set the Dome address to 1, SW1 1 ON, 2-8 OFF  
Protocol - Protocol and Baud, SW2 1-7 OFF, 8 ON, Pelco D - 2400 Baud  
Shorting the TEST link after power up will pan the dome LEFT and ZOOM IN. Releasing the short will stop pan and zoom out. This is allows confirmation of  
correct wiring and switch settings at the dome.  
Link J6/3-4 – Dome enters preset patrol after 5minutes of inactivity. Link J6/4-5 disabled.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Dennard type 2050/2055/2060 dome.  
Rx100 software RX1_D2V12  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus  
16 full scene presets (additional presets can be programmed using dome's menu)  
2 preset patrols  
4 alarm inputs driving to preset 1 - 4 or dome sequence 001 - 004, link selectable  
Advanced Features  
Dome User Menu  
Dome Supervisor Menu  
Dome Service Menu  
Tx400DC  
1 ‘#’  
2 ‘#’  
Tx1000  
'#' WASH  
'#' WIPE  
Tx1500 DM Mux  
1 ‘#’  
2 ‘#’  
3 ‘#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
3 ‘#’  
'#' AUTOPAN  
The domes internal Sequence 001 can be started by pressing AUTOPAN. The sequence must be programmed  
from the dome supervisor menu.  
RS485 control of dome using the following connections:  
Rx100  
J3-C1  
J3-C2  
Description  
TX-  
TX+  
Dome (old)  
Bs (White)  
As (Orange)  
Dome (current)  
Bs (Green)  
As (Yellow)  
7 pin socket  
Pin 3  
Pin 4  
The Dome must be addressed as 1 this is achieved by setting BLUE rotary sw. to 0 & YELLOW rotary sw. to 1  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up and following local alarm activation.  
Accessing the dome menus.  
Press relevant key combination to display menu. To select highlighted menu item, perform a goto preset 1 function as follows:- Tx1000 Hold the PRESET key  
and tap the CAM1 key, Tx400 press the PRESET1 key.  
The cursor can be moved using the standard pan/tilt keys or joystick. If the cursor direction is reversed, the pan and tilt cursor directions can be reversed from  
the SUPERVISOR, USER OPTIONS, CURSOR CONTROL REVERSE menu.  
Presets positions greater than 17 can be programmed using the dome's menu and can be built into dome sequences. Please refer to dome manual for specific  
instructions regarding programming of sequences.  
Local alarm can trigger either a dome preset sequence or goto a preset position depending upon the link J6/4-5. Complex alarm handling can be offered using a  
combination when used with the dome sequences. Eg when the link is fitted, an alarm can force the dome to a specific preset for a period. The dome can then  
move to another preset position at a programmed speed. Useful if an alarm area is say a fence line or building line with several doors/windows. Please view  
our web site for more information. www.bbvcctv.com  
Links  
Function  
J6/1-2  
Enable datum mode if fitted (goto preset 1 after 2 minutes if inactivity)  
J6/3, 4, 5 Select between presets or sequence following local alarm. Fitted to 4&5 = sequence 1-4, Fitted to 3&4 = preset 1-4  
A TEST link is used to confirm correct operation of the Rx100 and dome and also that the RS485 connection is correct. Shorting the link after the Rx100 is  
powered up will cause the dome to zoom in. Removing the link cause the dome to zoom out. The green data led should also flash to indicate RS485 sent to the  
dome.  
If the TEST link is shorted when power is applied to the Rx100 will cause a receiver self test function to start. This is an advanced function that BBV support  
engineers may request during fault diagnosis. To stop the self test, remove the link and power the Rx100 off and on again.  
To prevent difficulty when navigating through the dome menu local alarm input 1 is disabled for 4 minutes after the menu is  
displayed. To enable the alarm when out of the menu please press zoom in or zoom out. The alarm will then be re-enabled.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following dome:  
Dynacolor 7720  
COAXIAL TELEMETRY ONLY NOT 20mA  
Rx100 software RX1_D4V7  
Application Notes  
Variable speed Pan/Tilt (single function at a time, pan or tilt or zoom or focus)  
Zoom/Focus  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 – 4  
Additional Features  
Dome Menu and ENTER  
Exit Dome Menu  
Dome Reset  
Tx400 Tx1000  
Tx1500 DM Sprite  
DM/DS/DSL/DS2  
*889 10 10 2  
*889 10 10 3  
(twice)  
‘#’ 1  
‘#’ 2  
'#' WASH  
‘#’ WIPE  
1 '#'  
*889 002  
*889 003  
*889 005  
2 ‘#’  
4 ‘#’  
(3 times) ‘#’ 4  
‘#’ LIGHTS  
*889 10 10 5  
Menu access – example using the Tx1500 system  
Press 1# 1# will display the dome’s menu and put the Rx100 in menu mode. In this mode the joystick allows navigation and either IRIS  
OPEN or IRIS CLOSE or 1# is used when ENTER is required. After exiting the menu, press 2# to set the Rx100 back into normal mode and  
the joystick will then revert to pan/tilt control.  
Dome Reset  
This command will cause the dome to carry out a system reset, including erasing any preset positions and programming. This command must  
be used with extreme caution. To activation the dome reset, the command must entered 3 times, eg for the Tx1500, press 4# 4# 4#.  
Cruise  
Recording: The dome has a built in cruise facility allowing the operator to record and playback a period of manual dome movement. The  
exact procedure varies depending upon the control equipment and version of dome firmware. The example shown assumes that the dome is  
controlled using a Tx1500.  
To record the cruise, you must enter the dome menu using 1# 1# and navigate to the RECORD START entry within the CRUISE menu.  
After pressing the ENTER command using 1# you must exit the dome menu using 2# to allow the joystick to be used to move the dome  
around the intended area. To complete the cruise, press the Dome Menu command twice using 1# 2# to allow the joystick to be used to  
navigate to the RECORD END line. Pressing the ENTER command using 1# saves the cruise. Navigate out of the menu and exit the dome  
menu using 2#.  
Playback: The cruise can be started by pressing the AUTOPAN key on the controller.  
Return to home: Link J6/pin 4-5 if fitted will cause the dome to return to preset 8 after 5 minutes of inactivity. If function not required refit  
link to J6/pin 3-4.  
Speed select: Two versions of dome protocol are published. The early version has uses speeds 0 – 8 and the later version has speeds 0 – 15.  
Link J6/1-2 when fitted selects the later version and removed the earlier version. If the dome speed controls are very ‘sluggish’ then try  
operation with the link in the other position.  
RS485 control of dome. Data rate, 9600 Baud, No parity, 8 Data bits, 1 Stop bits  
Connection details:  
Dome  
D-  
D+  
Description  
RS485 Data -  
RS485 Data+  
Rx100  
J3/C1  
J3/C2  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Check with the DM multiplexer manual for exact procedure for entering * commands.  
Dome switch settings:  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Early dome - Set dome address to 1: 8 way switch 1 ON, 2-7 OFF. 4 way switch 1-3 ON, 4 OFF.  
Later dome – Dome ID switch: 1 ON, 2-8 OFF. Duplex/Simplex switch:1-2 OFF. Dynacolor protocol S2:1-4 OFF, S1:1-3 ON  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Forward Vision protocol  
including MIC1 300/400 series dome  
and compatible equipment.  
Rx100 software RX1_F1V8  
Application Notes  
Variable 16 speed Pan/Tilt.  
Zoom/Focus  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 - 4  
Advanced Features  
Tx400 Tx1000  
Tx1500 DM Mux DSL/DS2/BX2  
AUTO/MANUAL FOCUS TOGGLE ‘#’ 1  
‘#’ WASH  
'#' WIPE  
'#' AUTOPAN  
‘#’ LIGHTS  
1 ‘#’  
2 '#'  
3 '#'  
4 ‘#’  
*889 002 or *889 10 10 2 (twice)  
DIGITAL ZOOM ON/OFF  
MANUAL/AUTO EXPOSURE  
IR FILTER IN/OUT  
‘#’ 2  
‘#’ 3  
‘#’ 4  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
Version V4 of software has added support for PRIVACY ZONE programming. (TX1500 keystrokes shown)  
ENABLE ALL SCENE  
DISABLE ALL SCENE  
TOGGLE CURSOR ON/OFF  
ENABLE AROUND CURSOR  
DISABLE AROUND CURSOR  
1 ‘#’ PROGRAM 1 PRESET (Whole screen)  
1 ‘#’ PROGRAM 2 PRESET (Whole screen)  
1 ‘#’ PROGRAM 3 PRESET  
1 ‘#’ PROGRAM 4 PRESET (Centre of screen)  
1 ‘#’ PROGRAM 5 PRESET (Centre of screen)  
DM DS2 example to ENABLE ALL SCENE as privacy.  
*889 10 10 2 [PRESS AND HOLD ‘PRESET’] 1 [ENTER]  
RS485 control of dome using the following connections:  
Rx100  
J3-C1  
J3-C2  
Description  
RS485 IN(A)  
RS485 IN(B)  
Dome  
Yellow  
White  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up and following local alarm activation.  
A local alarm opening contact will cause the dome to move to the respective preset position. After 60 seconds the dome will revert to preset patrol if the patrol  
was active before the alarm occurred.  
Links  
J6/4-5  
J6/1-2  
Function  
Enable datum mode: Goto preset 1 or start Patrol 1 2 minutes after last activity. J6/3-4 = Function disabled.  
Select datum function: Fitted = goto preset 1, Removed = start Patrol 1  
TEST link when shorted will drive the dome LEFT and ZOOM IN. Removing the short will stop pan and ZOOM OUT. This is used to gain confidence that the  
wiring between Rx100 and dome is correct. The GREEN DATA led will flash when a command is sent to the dome.  
VERSION 6 now enables zoom proportional pan/tilt speed to improve manual control.  
For correct operation, ensure that the dome/head address is set to 01.  
Please contact Forward Vision for exact procedure on +44(0)870 011 3131.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following dome:  
JVC TK-C655B/676/675B combination cameras  
Rx100 software RX1_J2V4  
Application Notes  
The RX 100 provides the following functionality when controlling the above mentioned domes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus can be enabled/disabled from the dome menu.  
16 Full scene presets.  
2 preset patrols.  
Slow patrol or dome autopan from controller AUTOPAN key  
4 alarm inputs driving to preset 1 - 4.  
Additional commands:  
TK-C676  
Tx400DC Tx1000  
Tx1500 DM System Sprite, DS, DS2, BX2  
OPEN MENU and BACK (Twice)  
SET  
Togggle ExDR  
Cycle Mono Mode  
‘#’1’  
'#' 2  
'#' 3  
'#' 4  
#' WASH  
'#' WIPE  
'#' AUTOPAN  
'#' LIGHTS  
1 ‘#’  
2 ‘#’  
3 ‘#’  
4 ‘#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
RS485 control of dome using the following connections:  
Rx100  
J3-C1  
J3-C2  
Description  
TX-  
TX+  
Dome connection  
CONTROL RX- (D)  
CONTROL RX+ (C)  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Camera switch settings:  
MACHINE ID – set both rotary switches to ‘0’  
8 way DIL switch, all OFF apart from 8 which should be ON to enable the RS485 termination, point-to-point, simplex.  
On screen display of preset position, HOME - P16 or MANUAL during manual control. The on screen display can be enabled/disabled using dome switch  
SW3, ON = Display off, OFF = Display on.  
J6 links.  
J6/1-2: Link fitted across J6/1 and J6/2 (default) to allow the ExDR and MONO mode status to be displayed. Remove this link if you are programming a dome  
camera title and do not want to display the ExDR and MONO status.  
J6/4-5: Fitted (default) dome will perform a slow patrol between programmed presets when AUTOPAN pressed. Removed and fitted to J6/3-4 will send  
autopan start to the dome.  
DOME MENU  
Pressing #1 twice will display the dome’s menu. The joystick is then used to navigate through the dome menu. #2 sends a SET command to the dome and #1  
twice whilst the menu is displayed sends a BACK command.  
If the #1 command doesn’t work press a focus key before sending #1.  
Pressing #1 FOUR times within 2 seconds will display the dome’s service menu.  
PRESET POSITIONS  
The dome has a home preset position which is preset 00.  
To enable this preset to be programmed when using the Rx100/JVC676 programming preset 1. BBV Presets 2 – 16 refer to the dome presets 2 – 16.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following domes:  
Kalatel Cyberdome (Firmware 1/1/02 or later)  
Rx100 software RX1_K1V2  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus/Iris  
16 Full scene presets.  
2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 03)  
Shadow TOUR 1 playback using AUTOPAN key.  
Menu navigation including programming privacy zones etc  
Advanced Features  
Toggle MENU ON/OFF '#' WASH  
Toggle PTZ/CURSOR '#' WIPE  
(see GOTO PRESET 16 BELOW)  
Tx1000  
Tx1500  
1 ’#’  
2 ’#’  
DM DS/DS2/BX2 Mux  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
The dome and Rx100 are linked using RS485 for control and video for the camera signal.  
Rx100  
J3-C1  
J3-C2  
Description  
TX-/B  
TX+/A  
Dome connection  
RS485 B -  
RS485 A +  
Notes:  
The dome address must be set at 1 for all the cameras that are controlled using a Rx100. Check with the dome manual if you  
have any doubts.  
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.  
The dome will be driven to a preset following a local alarm activation. 60 seconds after alarm, the shadow tour will restart if  
running when the alarm occured. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until  
the next manual pan command. If PATROL 1 was running when a local alarm occurs after 60 seconds the patrol will be  
resumed.  
The dome’s TOUR 3 must be programmed from within the domes menu. Please refer to the dome manual for details. 2  
PATROL from TX1500 or PATROL 2 from TX1000 to start this tour.  
Programming preset 1 will also program the dome’s home preset – 00.  
Navigating the dome’s menu requires several key presses that may not be available with all controllers.  
These key presses are simulated using GOTO PRESET commands as follows.  
<1> – <9> = GOTO PRESET 1 – 9  
<SEQ> = GOTO PRESET 11  
<CLEAR> = GOTO PRESET 14  
<0>  
<ALARM>  
<SET>  
= GOTO PRESET 10  
= GOTO PRESET 12  
= GOTO PRESET 15  
<1ST> = GOTO PRESET 13  
GOTO PRESET 16 - This is used to toggle the joystick between dome movement and cursor movement which is needed for  
some menus eg preset and area titles.  
The TEST link can be used to prove correct data connection between the RX100 and dome. When the link is fitted the dome  
should pan left. Removing the link will stop the pan. Ensure that the link is removed before powering the RX100 on as this is  
to enter diagnostics mode.  
Due to the number of presets required to navigate in the dome menu the TX400 and TX400DC, which have 8 presets, will not  
be able to navigate the menu fully.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following dome:  
Merit Li-Lin  
PIH-717X/7000/7600/7625 series  
Rx100 software RX1_L1V8  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 - 4  
Advanced Features  
Toggle Menu display  
Enable Auto-Iris  
Dome reset step 1  
Exit menu  
Tx400 Tx1000  
Tx1500 DM Sprite/DS/DSL/DS2/BX2  
‘#’ 1  
‘#’ 2  
‘#’ 3  
‘#’ 4  
‘#’ WASH  
'#' WIPE  
'#' AUTOPAN 3 '#'  
'#' LIGHTS 4 '#'  
1 ‘#’  
2 ‘#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
Procedure to program preset positions. The procedure must be followed to program new preset positions and also to re-  
program existing positions.  
The keystrokes shown below assume use of a Tx1000.  
1) Select GOTO PRESET number to program eg 1  
Hold PRESET tap 1  
2) Move dome to new position using joystick and lens keys.  
3) Select PROGRAM PRESET to save new position.  
Press PROGRAM 1 1  
To stop dome from running its own internal Autopan move joystick then press AUTOPAN.  
RS485 connections between Rx100 and dome.  
PIH717(DB15) or  
Pin 14  
Pin 15  
PIH7000/7600  
Description  
J3/C1  
J3/C2  
Rx100  
TXDI-  
TXDI+  
-Data  
+Data  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
A 2 minute datum mode is available. 2 minutes after the last manual command, the dome will either move to preset 1 or start an autopan. Fit link J6/1-2 to  
enable this feature. J6/4-5 fitted = autopan, J6/3-4 fitted = goto preset 1.  
All dome preset positions can be deleted using #3 followed by #4 within 1 second.  
Check with the DM multiplexer manual for exact procedure for entering * commands.  
IMPORTANT: Dome settings: Select dome address #1.  
To aid diagnostics and confirm correct connection between the Rx100 and dome, the TEST link when shorted will drive the  
dome LEFT until the short is removed. Whilst the Rx100 is sending data to the dome the GREEN DATA will flash.  
V6 software – 1# now used to toggle menu display on/off. In previous versions this was used to toggle AUTOPAN which is  
now not required with current generation of LiLin dome.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Mark Mercer 150 and D250/500 series  
Rx100 software RX1_M1V6  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus override, Iris override  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 – 4  
2 minute datum (park) mode, link selectable as either preset 1 or slow preset patrol.  
Advanced Features  
Pan ‘U’-turn (180deg flip) ‘#’ 1  
Dome Reset ‘#’ 4  
Tx400 Tx1000  
Tx1500 DM Mux/DS/DSL/DS2/BX2 etc  
'#' WASH  
‘#’ LIGHTS  
1 ‘#’  
4 ‘#’  
*889 002 or *889 10 10 2  
*889 005 or *889 10 10 5  
A slow preset patrol can be started by pressing AUTOPAN. The preset dwell is fixed at 20 seconds with a dome speed of 1.  
RS485 control of dome using the following connections:  
Rx100  
J3-C1  
J3-C2  
Description  
TX/RX-  
TX/RX+  
Dome  
RS485 B Pin 4 (RED)  
RS485 A Pin 3 (GREEN)  
6 pin connector  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up and following a local alarm activation.  
Links  
J6/1-2  
Function  
Enable 2 minute inactivity datum mode if the link is fitted.  
J6/3,4,5 Select datum operation, J6/4-5 = goto preset 1, J6/3-4 = start slow preset patrol.  
Only operational whilst the dome is not running a patrol.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Panasonic WV-CSR400 series.  
WV-CSR600 series.  
WV-CSR650 series.  
Rx100 software RX1_P1V5B  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus, Iris Open/Close (AutoFocus with 600 & 650 series)  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 - 4.  
Autopan  
(600 & 650 series dome)  
(600 & 650 series dome)  
(600 & 650 series dome )  
Advanced Features  
Tx400 Tx1000  
Tx1500 DM Sprite/DSL/DS2/BX2  
Entry/Exit Dome Menu  
SET (select menu item)  
ESC (back to previous menu)  
SPECIAL2 (for special menus)  
‘#’ 1  
‘#’ 2  
‘#’ 3  
‘#’ 4  
'#' WASH  
'#' WIPE  
'#' AUTOPAN 3 ‘#’  
'#' LIGHTS 4 ‘#’  
1 ‘#’  
2 ‘#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
Autopan is started by selecting Autopan on the Transmitter. The Autopan stops can be programmed from within the dome  
menu. Please refer to dome user manual for exact details.  
RS485 control of dome. Connect dome FCC-68 plug into J7 of Rx100. If the dome cable requires extending, connect cores as  
follows:  
Dome Cable  
Yellow  
Green  
Description  
Data-  
Data+  
Rx100  
J3/C1  
J3/C2  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Accessing the dome menus.  
Press either '#'WASH , '#'1 or *889 002 key strokes to Enter Menu. Use Pan/Tilt to highlight item. Press either '#'WIPE, '#'2 or *889 003 key strokes to select  
menu item. To exit from menu, press either '#'WASH, '#'1 or *889 002.  
Check with the multiplexer manual for exact procedure for entering * commands.  
IMPORTANT: Dome settings: Select dome address 01. Communications must be 19200, N, 8, 1. If dome cannot be controlled, see dome manual section to  
reset dome to factory default.  
The Panasonic CS-850 can be controlled using an Rx100 with Rx1_P1V6 software order code RX100/Panasonic CS850.  
The TEST link will pan the dome left whilst shorted. The video out BNC must be disconnected before the TEST link is fitted.  
The GREEN DATA flashes when data is sent from the Rx100.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Panasonic WV-CS850 / 860  
Rx100 software RX1_P1V10  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus, Iris Open/Close (Hold for auto-iris)  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 – 4  
Autopan/Patrol learn-play using autopan key  
Advanced Features  
ENTRY/EXIT Dome Menu  
SET (select menu item)  
ESC (back to previous menu)  
SPECIAL2 (for special menus)  
Tx400  
‘#’ 1  
‘#’ 2  
‘#’ 3  
‘#’ 4  
Tx1000  
'#' WASH  
'#' WIPE  
'#' AUTOPAN  
'#' LIGHTS  
Tx1500 DM Sprite/DS/DS2/BX2  
1 ’#’  
2 ’#’  
3 ’#'  
4 '#'  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
A dome RESET ALL command can be sent by holding either ‘#’LIGHTS or ‘#’4 for 5 seconds when not within the menu. Care must be used with this  
command as the dome is set to default and user settings are erased.  
The dome’s internal PATROL can be LEARNED using the dome menu. Setting the AUTO PAN KEY to PATROL will allow the patrol to be PLAYED by  
pressing AUTOPAN on the controller.  
RS485 control of dome. Connect dome FCC-68 plug into J7 of Rx100. If the dome cable requires extending, connect cores as follows:  
Dome Cable  
Yellow  
Green  
Description  
Data-  
Data+  
Rx100  
J3/C1  
J3/C2  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Accessing the dome menus.  
Press either '#'WASH , '#'1 or *889 002 key strokes to Enter Menu. Use Pan/Tilt to highlight item. Press either '#'WIPE, '#'2 or *889 003 key strokes to select  
menu item. ‘#’WASH , ‘#’3 or *889 004 is used to ESCAPE back to previous menu. SPECIAL2 menus are accessed using ‘#’LIGHTS, ‘#’4 or *889 005. To  
exit from menu, press either '#'WASH, '#'1 or *889 002.  
Check with the multiplexer manual for exact procedure for entering * commands.  
Dome Switch settings: The following procedure must be followed to ensure that the dome is set-up correctly for terminated 4 wire RS485 at 19200 Baud and  
address 1. Remove the dome from it’s base before each step and reconnect to the base after changing the switches.  
Step 1: Address switches 2,4 and 5 ON  
Step 2: Address switches 1,3,4 and 5 ON  
Step 3: Address switches 1 and 8 ON. 4 Way switch 1 ON to select 4 wire, terminated RS485.  
Panasonic WV-CSR400/600/650 domes can be controlled using a different version of Rx100 software. Please contact BBV for further information or check out  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following dome:  
Pelco Spectra (P-mode RS485 protocol)  
Rx100 software RX1_P2V10  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus  
16 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 - 4  
Dome Pattern definition and playback  
Advanced Features  
Tx1000  
'#' WASH  
'#' WIPE  
'#' AUTOPAN  
‘#’ LIGHTS  
Tx400 DM-Sprite  
DM-DSL/DS/DS2  
*889 10 10 2  
*889 10 10 3  
*889 10 10 4  
*889 10 10 5  
Display dome menu (preset 95)  
Enter within menu (iris open)  
Pattern define start  
'#' 1  
'#' 2  
'#' 3  
‘#’ 4  
*889 002  
*889 003  
*889 004  
*889 005  
Pattern define stop  
To record a Pattern, direct the camera to the required starting position. Hold '#' and tap 'AUTOPAN'. The dome will now record pan/tilt  
and lens movement up to a time limit. To stop the recording, hold '#' and tap 'LIGHTS’. To play the recorded Pattern, press the AUTOPAN  
key only. The dome will repeatedly run the Pattern until either the joystick is moved or an alarm occurs.  
(The example shows Tx1000 keystrokes, please substitute the keystroke for the controller used.)  
Menu access:  
Use ‘#’ WASH to display menu. Navigate using the joystick and IRIS OPEN to select. When used with control systems without iris keys,  
eg DM Digital Sprite Lite, use *889 003 or *889 10 10 3  
Return to home: Can be programmed from the Dome menu.  
RS485 control of dome. Data rate, 9600 Baud, No parity, 8 Data bits, 1 Stop bits  
Connection details:  
Dome  
RX-  
RX+  
Description  
RS485(B) input  
RS485(A) input  
Rx100  
J3/C1  
J3/C2  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Check with the DM multiplexer manual for exact procedure for entering * commands.  
Dome settings: Select dome address 1, P-MODE PROTOCOL and 9600, N, 8, 1.  
Link J6/1-2 is used to select the function that is used to drive the Esprit AUX outputs.  
Function  
LIGHTS  
WIPER  
Link fitted Esprit AUX No  
Link removed Esprit AUX No  
1
2
2
3
1
3
WASHER  
Link J6/4-5 is used to enable 5 minute datum time to start preset patrol.  
Link fitted = datum disabled and link removed = datum enabled.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following dome:  
Philips AutoDome including G3A and G3B  
(RS232 control only, not Bi-Phase compatible)  
Rx100 software RX1_P3V11  
Application Notes  
Variable speed Pan/Tilt.. Zoom/Focus, Autofocus. 16 full scene presets. 2 preset patrols. 4 alarm inputs driving to preset 1 – 4.  
Dome AutoPlay record & playback. Preshot title, Zone title, Menu Access  
Advanced Features  
Display Menu  
Program Zone Title(Aux 63)  
Record AutoPlay start/stop (Aux 100) '#' 3  
RESET DOME! '#' 4  
Tx400DC  
'#' 1  
'#' 2  
Tx1000  
‘#’ WASH  
‘#’ WIPE  
‘#’ AUTOPAN  
‘#’ LIGHTS  
Tx1500 DM Sprite  
DS/DSL/DS2/BX2  
*889 10 10 2  
*889 10 10 3  
*889 10 10 4  
*889 10 10 5  
(Aux 46)  
1'#'  
2'#'  
3'#'  
4'#'  
*889 002  
*889 003  
*889 004  
*889 005  
(Set 899)  
RS232 control of dome. Data rate, 9600 Baud, No parity, 8 Data bits, 1 Stop bits  
Connection details:  
Dome  
RxD  
Gnd  
Description  
RS232 I/P  
Gnd  
Rx100 or DMP100/124  
J3/C1  
J3/GND  
Notes:  
Configuration links:  
J6/pin 1-2 is used to select the address that the unit outputs. Fitted(Default) = Address 1, Removed = Address 10,000.  
Removing the link allows the receiver to be used as an alarm input unit for domes that are controlled using bi-phase telemetry. This will work with late model  
domes with post 2002 software.  
J6/pin3-4 – preset title text is programmed following a save preset command by automatically issuing a aux(62) command.  
J6/pin4-5 (Default) – the preset text command is not sent and the existing text is retained.  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
The dome must be RS232 controllable. BI-PHASE domes cannot be controlled.  
Dome settings: Select dome address #0 or #1. Communications must be 9600, N, 8, 1. The G3 Basic address is software programmable, however as default  
the dome is addressed as #0. If the dome address is not #0 or #1 then the dome will require reprogramming using a Philips controller or removing link J6/1-2.  
A TEST link is used to confirm correct operation of the Rx100 and dome and also that the RS485 connection is correct. Shorting the link after the Rx100 is  
powered up will cause the dome to pan left and zoom in. Removing the link cause the dome to zoom out and stop panning left. The green data led should also  
flash to indicate RS485 sent to the dome.  
If the TEST link is shorted when power is applied to the Rx100 will cause a receiver self test function to start. This is an advanced function that BBV support  
engineers may request during fault diagnosis. To stop the self test, remove the link and power the Rx100 off and on again.  
Using the advanced features when using a BBV Tx1000DC  
Menu Access: Press and HOLD # and tap WASH TWICE will display the dome’s menu.  
Use the joystick to navigate the cursor. FOCUS FAR or FOCUS NEAR can be pressed to enter the next menu item or to return press either  
IRIS OPEN or IRIS CLOSE. When completely out of the menu issue a goto preset command to put the interface into normal mode. Press  
and HOLD PRESET whilst taping 1 will move to preshot 1.  
Program Zone Title: Press and HOLD # and tap WIPE will allow the title for the current zone to be programmed.  
Use the joystick as described on screen. Use the following keystrokes to program the text:  
FOCUS NEAR – Select a current character, FOCUS FAR – Clear character, IRIS CLOSE – Backspace and IRIS OPEN – Return  
Record Autoplay: Press and HOLD # and tap AUTOPAN will allow autoplay ‘A’ to be recorded.  
Press FOCUS FAR or FOCUS NEAR to start the recording or IRIS CLOSE to abandon recording. Once recording has started, use the  
joystick and focus keys as required. To end the recording, press and HOLD # and tap AUTOPAN. The recording can be replayed  
continuously be pressing the AUTOPAN key.  
Reset dome defaults: Press and HOLD # and tap LIGHTS TWICE to display the dome’s software version. Repeating the key  
strokes for a THIRD time will issue a SET 899 to reset the dome including ALL PRESET POSITIONS.  
USE WITH EXTREME CARE AS ALL THE DOME PROGRAMMING WILL BE LOST.  
Programming preshot text. To program a preshot position press PROGRAM then 1 followed by number of the preshot. EG to program  
preshot 1 press PROGRAM 1 1. To program preshot 2 press PROGRAM 1 2. To program preset 14 press PROGRAM 1 14. After the  
preshot has been programmed the interface issues an AUX 62 to display the preshot text menu. The same keystrokes are used to program  
preshot text as when programming zone titles.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the advanced features when using a BBV Tx400DC  
Menu Access: Press and HOLD # and tap 1 TWICE will display the dome’s menu  
Use the joystick to navigate the cursor. FOCUS FAR or FOCUS NEAR can be pressed to enter the next menu item or to return press either  
IRIS OPEN or IRIS CLOSE. When completely out of the menu issue a goto preset command to put the Rx100 into normal mode. Press 1  
will move to preshot 1.  
Program Zone Title: Press and HOLD # and tap 2 will allow the title for the current zone to be programmed.  
Use the joystick as described on screen. Use the following keystrokes to program the text:  
FOCUS NEAR – Select a current character, FOCUS FAR – Clear character, IRIS CLOSE – Backspace and IRIS OPEN – Return  
Record Autoplay: Press and HOLD # and tap 3 allow autoplay ‘A’ to be recorded.  
Press FOCUS FAR or FOCUS NEAR to start the recording or IRIS CLOSE to abandon recording. Once recording has started, use the  
joystick and focus keys as required. To end the recording, press and HOLD # and tap 3. The recording can be replayed continuously be  
pressing the AUTOPAN key.  
Reset dome defaults: Press and HOLD # and tap 4 TWICE to display the dome’s software version. Repeating the key strokes for a  
THIRD time will issue a SET 899 to reset the dome including ALL PRESET POSITIONS.  
USE WITH EXTREME CARE AS ALL THE DOME PROGRAMMING WILL BE LOST.  
Programming preshot text. To program a preshot position press and HOLD PROGRAM then tap the preshot require, 1 – 8.  
EG to program preshot 1 press and HOLD PROGRAM then tap 1. To program preshot 2 press and HOLD PROGRAM and tap 2. To  
program preset 8 press and HOLD PROGRAM and tap 8. After the preshot has been programmed the Rx100 issues an AUX 62 to display  
the preshot text menu. The same keystrokes are used to program preshot text as when programming zone titles.  
Using the advanced features when using a DM Sprite and Digital Sprite keyboard.  
The DM units use a series of * commands to access the advanced features. The Digital Sprite or DS does not have a ‘0’ key  
instead the ‘10’ key is used when ever the ‘0’ key is mentioned. Eg to access the dome menu on a System Sprite you would  
key *889 002 and on the Digital DS you would key in *889 10 10 2. The examples below assume control from the Digital  
Sprite keyboard. If a System Sprite is used then please use the ‘0’ key whenever the ‘10’ key is mentioned.  
Menu Access: *889 10 10 2 repeated TWICE will display the dome’s menu  
Use the joystick to navigate the cursor. FOCUS FAR or FOCUS NEAR can be pressed to enter the next menu item or to return use *889 10  
10 3 which simulates an iris command. When completely out of the menu issue a goto preset command to put the Rx100 into normal mode.  
Pressing PRESET followed by 10 1 will goto preshot 1.  
Program Zone Title: *889 10 10 3 will allow the title for the current zone to be programmed.  
Use the joystick as described on screen. Use the following keystrokes to program the text:  
FOCUS NEAR – Select a current character, FOCUS FAR – Clear character, *889 10 10 4 – Backspace and *889 10 10 3 – Return  
Record Autoplay: *889 10 10 4 will allow autoplay A to be recorded.  
Press FOCUS FAR or FOCUS NEAR to start the recording or *889 10 10 3 to abandon recording. Once recording has started, use the  
joystick and focus keys as required. To end the recording, press *889 10 10 4. The recording can be replayed continuously be pressing the  
AUTOPAN key.  
Reset dome defaults: *889 10 10 5 repeated TWICE to display the dome’s software version. Repeating the key strokes for a  
THIRD time will issue a SET 899 to reset the dome including ALL PRESET POSITIONS.  
USE WITH EXTREME CARE AS ALL THE DOME PROGRAMMING WILL BE LOST.  
Programming preshot text. To program a preshot position press and hold the PRESET button until the display asks for preset number.  
Use the camera keys to enter a 2 digit number from 01 – 16. Use the 10 key to represent 0. After the preshot has been programmed the  
Rx100 issues an AUX 62 to display the preshot text menu. The same keystrokes are used to program preshot text as when programming zone  
titles. EG to program preshot 2, press and hold PRESET, wait for the display, press 10 then 2.  
Control from DM Digital Sprite 2 systems  
The new DM Digital Sprite 2 (DS2) keyboard now supports iris directly again. Therefore navigation through the menus will be easier.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 & Rx100/24  
Addendum to manual for the following domes:  
Samsung SCC-641 Interface  
Rx100 software RX1_S5V3  
Application Notes  
The Rx100 allows control of the following dome features: Variable speed Pan/Tilt, Zoom/Focus/Iris, 16 full scene presets,  
2 preset patrols, 4 alarm inputs driving to preset 1 – 4, Dome Pattern 1 playback using the AUTOPAN key ,Menu Access  
Advanced Features  
Display Menu (Twice)  
Turn Menu Off  
ENTER within menu  
Dome FACTORY RESET '#' LIGHTS  
BBV Tx1000  
'#' WASH  
'#' WIPE  
BBV Tx400  
'#' 1  
'#' 2  
'#' 3  
'#' 4  
DM Sprite  
*889 002  
*889 003  
*889 004  
*889 005  
DS/DSL  
*889 10 10 2  
*889 10 10 3  
*889 10 10 4  
*889 10 10 5  
'#' AUTOPAN  
RS485 control of dome. Data rate link selectable using J6/1-2. Fitted = 9600,N,8,1 and removed = 19200,N,8,1  
Connection details:  
Dome  
RX-  
RX+  
RX100  
J3/C1  
J3/C2  
Notes:  
J6/pin 1-2 is used to select the baud rate to drive the dome, either 9600 or 19200 baud.  
Fitted(Default) = 9600,N,8,1 Removed = 19200,N,8,1(used if experience run on problems with 20mA telemetry)  
The dome’s SW500 and SW501 switches must be set as follows:  
SW500 sets the dome’s address to 01. 1 = ON, 2,3,4,5,6,7,8 = OFF  
SW501 is used to set the dome’s RS485 baud rate, Termination and protocol selection.  
For 9600 baud set as follows: 1,2,3,5 = ON 4,6,7,8 = OFF  
For 19200 baud set as follows: 1,2,3,4 = ON 5,6,7,8 = OFF  
Menu Access when using a BBV Tx1000DC  
Display Menu: Press and HOLD # and tap WASH TWICE will display the dome’s menu.  
Use the joystick to navigate the cursor and HOLD # and tap AUTOPAN as ENTER.  
Turn Menu Off: Press and HOLD # and tap WIPE  
Dome FACTORY RESET: Press and HOLD # and tap LIGHTS THREE times to return the dome to factory defaults.  
Menu Access when using a BBV Tx400DC  
Display Menu: Press and HOLD # and tap 1 TWICE will display the dome’s menu.  
Use the joystick to navigate the cursor and HOLD # and tap 3 as ENTER.  
Turn Menu Off: Press and HOLD # and tap 2  
Dome FACTORY RESET: Press and HOLD # and tap 4 THREE times to return the dome to factory defaults.  
Menu Access when using DM DS/DSL/DS2  
Display Menu: *889 10 10 2 TWICE will display the dome’s menu.  
Use the joystick to navigate the cursor and *889 10 10 4 as ENTER.  
Turn Menu Off: *889 10 10 3  
Dome FACTORY RESET: *889 10 10 5 THREE times to return the dome to factory defaults.  
CAUTION – READ BEFORE PERFORMING A DOME FACTORY RESET!  
USE WITH EXTREME CARE AS ALL THE DOME PROGRAMMING INCLUDING PRESET POSITIONS WILL BE  
LOST.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Sensormatic Speeddome  
Rx100 software RX1_S3V6  
Coaxial telemetry ONLY. Not twisted pair!  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus, Iris Open/Close  
7 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 – 4  
Pattern 1 define – play using Autopan key  
Advanced Features  
Tx1000  
Tx400 DM DS/DS2/BX2  
Start/Stop PATTERN1 Definition  
(Press AUTOPAN to Run Pattern1)  
Dome Menu  
'#' WASH  
'#' 1  
*889 002 or *889 10 10 2  
'#' LIGHTS  
'#' 4  
*889 005 or *889 10 10 5  
RS485 control of dome 4800 Baud, No parity, 8 data bits, 2 stop bits.  
Dome Cable  
RS422 IN-/Data In-  
RS422 IN+/Data In+  
Description  
Data-(B)  
Data+(A)  
Rx100  
J3/C1  
J3/C2  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Accessing the dome menus.  
Press either '#'LIGHTS , '#'4 or *889 005 key strokes to Enter Menu. Use Pan/Tilt/zoom/focus functions are then used to navigate through menu structure.  
Please refer to individual dome manual for exact operation of menu.  
Check with the multiplexer manual for exact procedure for entering * commands.  
IMPORTANT:  
Dome settings: Select dome address 01 or 001.  
Communications must be 4800, N, 8, 2 – RS422, NOT SensorNet.  
The interface software is based on 1997 protocol and has been tested with Ultradome IV, Ultradome VI and original Speeddome.  
Link J6/1-2 used to enable/disable datum mode to start preset patrol.  
Link fitted = datum disables  
Link removed = datum enabled, start preset patrol after 60 seconds of inactivity  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following camera:  
Sony EVI-D31 Webcam  
Rx100 software RXS4V3  
Coaxial telemetry ONLY. Not twisted pair.  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus with manual override (returns to auto following zoom command)  
6 full scene presets  
2 preset patrols  
4 alarm inputs driving to preset 1 – 4  
Advanced Features  
Toggle Backlight compensation  
Cycle White Balance  
Tx400 Tx1000  
'#' ‘1’ ‘#’ WASH  
‘#’ ‘2’ ‘#’ WIPE  
Tx1500 DM Sprite/DS2/BX2  
1 ‘#’  
2 ‘#’  
*889 002 or 10 10 2  
*889 003 or 10 10 3  
AUTO, INDOOR, OUTDOOR  
Toggle AutoExposure/Bright mode  
Iris keys used in Bright mode  
Reset dome to default  
‘#’ ‘3’ ‘#’ AUTOPAN 3 ‘#’  
‘#’ ‘4’ ‘#’ LIGHTS 4 ‘#’  
*889 004 or 10 10 4  
*889 005 or 10 10 5  
RS232 control of dome 9600 Baud, No parity, 8 data bits, 1 stop bit. The camera uses a sub-miniature 8 pin DIN socket. A  
Sony supplied VISCA to DB9 RS232 cable may help with installation.  
Connection details:  
Camera Pin  
5
4 or 6  
Description  
Receive Data  
Ground  
Rx100  
J3/C1  
J3/GND  
Notes:  
Link J6/1-2 selects a 5 minute datum mode. If fitted and no activity for 5 minutes, the camera will drive to either preset 1 or start PATROL 1 depending on link  
J6/3,4,5, Fitted to J6/4&5 = Goto Preset 1 or fitted to J6/3&4 = start PATROL 1.  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Check with the multiplexer manual for exact procedure for entering * commands.  
IMPORTANT:  
Ensure that CAMERA NO switch on the camera rear panel is set to 1.  
As communications is RS232 please limit cable from Rx100 to camera to less than 5M.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Chugai SMD-08II, SMD-12, SMD-12II, SMD-20  
Sanyo VCC-9200P  
Star MD-800, MD-1200S, MD-1200H, MD-2000  
Rx100 software RX1_S2V6  
Application Notes  
The RX 100 provide the following functionality when controlling the above mentioned domes  
Variable speed Pan/Tilt, from 0.8deg/sec to 120deg/sec.  
Zoom/Focus, Autofocus following a Zoom In/Out.  
(Autofocus enabled with link fitted on J6 pin 1&2)  
16 Full scene presets.  
2 preset patrols.  
4 alarm inputs.  
Additional commands:  
AUTOPAN: Pressing the AUTOPAN key will run the domes in-built swing feature. Preset positions 1 & 8 must be  
programmed before the swing is started. Preset 1 is the right hand stop, preset 8 is the left hand stop. Tilt and lens can be  
adjusted whilst the dome is swinging.  
180deg PAN AUTO FLIP is accomplished by pressing either '#'WASH on Tx1000 or '#'1 on Tx400.  
DOME REMOTE RESET can be started by pressing either '#'LIGHTS on Tx1000 or '#'4 on Tx400.  
RS485 control of dome using the following connections:  
Rx100  
Description  
Dome mounting bracket  
J3-C1 TX/RX- Data-  
J3-C2 TX/RX+ Data+  
Pin 2  
Pin 1  
Notes:  
The alarm output relay opens for approx 2 seconds upon power up. This can be used to signal power loss, etc.  
When programming a preset position, control is prohibited until the dome has stored the position into it's eeprom memory, approx 1-2 seconds.  
Following a goto preset command, all further commands are ignored until the dome has reached it's preset position including any alarm input.  
If swing is running, start patrol 1 & 2 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, swing will restart.  
If a manual goto preset is pressed, the dome will stop swinging and move to the preset position. The AUTOPAN led will be on until the next manual pan  
command.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following dome:  
Diamond/Ultrak KD6 Dome  
Rx100 software RX1_D1V5  
up-the-coax telemetry only. Not twisted pair  
Application Notes  
Variable speed Pan/Tilt.  
Zoom/Focus, Iris override, Auto exposure ON/OFF  
16 Full scene presets.  
2 preset patrols.  
4 alarm inputs driving to preset 1 - 4.  
Advanced Features  
DOME MENU  
Auto Exposure  
Program PTZ Tour1 toggle (pshot 83/86)  
Start PTZ Tour1 (pshot 80)  
Tx400  
‘#’1  
'#' 2  
'#' 3  
‘#’ 4  
Tx1000  
'#' WASH  
'#' WIPE  
‘#' AUTOPAN  
‘#’ LIGHTS  
TX1500 DM Mux or DS/DS2/BX2  
(pshot 90)  
(auto-iris) toggle (pshot 92)  
1’#’  
2’#’  
3’#’  
4’#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
VectorScan 0 is started by pressing AUTOPAN and is programmed using the dome menu (see notes).  
A datum or home facility is provided. This is link selectable to either move to preset 1 or start VectorScan 0. Link J6/1-2 fitted enables datum mode. Link  
J6/4-5 fitted selects preset 1 and removed selects VectorScan 0. The timeout is fixed at 5 minutes after the last movement command.  
RS485 control of dome using the following connections:  
Rx100  
J3-C1  
J3-C2  
Description  
TX/RX-  
TX/RX+  
Dome connection  
RX-  
RX+  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
Whilst within PATROL1, PATROL2, VECTORSCAN or PTZ Tour a local alarm input will drive the dome to the active alarm preset position at full speed.  
The dome will remain in this position for approx 60 seconds, after which time the patrol, VectorScan etc will resume. Additionally, if the dome is running  
PATROL1 or 2 a manual preset command will move the dome to this preset position for 60 seconds before continuing with the patrol.  
The dome must be configured as follows:  
Select 9600 Baud communications. To use the dome’s advanced features including the menu, select MAXPRO telemetry. The exact switch setting for  
MAXPRO telemetry depends on the dome’s internal firmware version as below:  
Version  
J/K  
H
S4-1  
closed  
open  
S4-2  
S4-3  
open  
open  
open  
S4-4  
open  
closed  
open  
open  
open  
closed  
G
closed  
Three rotary switches set the dome address to 000. S1 = ‘0’, S2 = ‘0’, S3 = ‘0’.  
The dome menu allows setting of several internal dome features. Once activated using ‘#’WASH etc, navigate using the pan/tilt direction keys/joystick.  
Generally the IRIS OPEN key is used as a ENTER key and the IRIS CLOSE key is used as an ESCAPE key. The dome manual should explain in greater detail.  
On screen text can be enabled using the dome menu.  
It is recommended that the dome is operated with the auto exposure set to ON to allow automatic compensation for varying lighting conditions.  
Due to the dome protocol requirements, telemetry control is up-the-coax only. 20mA twisted pair telemetry is not currently supported. (Software version  
Rx1_D1V5)  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
VCL TP protocol Microsphere/Orbiter range.  
Rx100 software RX1_V1V10  
Application Notes  
The RX 100 provide the following functionality when controlling the above mentioned domes  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus following a Zoom In/Out.  
16 Full scene presets.  
2 preset patrols.  
Slow preset tour. Started by pressing AUTOPAN  
5 minute datum/park driving to preset 8 disabled by removing link J6/4-5  
Program up to 16 privacy zones  
Additional commands:  
AUTOPAN: Pressing the AUTOPAN key will run the domes preset tour at slow speed between the patrol 1 preset positions.  
Advanced Features  
180 degree pan flip  
Privacy SET (Toggle Mono/Colour)  
Privacy CLEAR (Auto Mono/Colour)  
Reset dome parameters  
Tx400  
‘#’ 1  
‘#’ 2  
‘#’ 3  
‘#’ 4  
Tx1000  
'#' WASH  
'#' WIPE  
'#' AUTOPAN  
'#' LIGHTS  
Tx1500 DM DS/DS2/BX2 Mux  
1 ’#’  
2 ’#’  
3 ’#’  
4 ’#’  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
The dome and Rx100 are linked using RS485 for control and video for the camera signal.  
Rx100  
J3-C1  
J3-C2  
Description  
TX-/B  
TX+/A  
Dome connection  
D-  
D+  
Notes:  
The dome address must be set at 1 for all the cameras that are controlled using a Rx100. With an Orbiter Gold, set the address to 1 with all switches of DILSW2  
ON. Select VCL protocol with all switches of DILSW1 OFF. Check with the dome manual if you have any doubts.  
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.  
If the slow preset tour is running, start patrol 1 & 2 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, the  
tour will restart. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until the next manual pan command.  
A datum/park mode is offered that drives the dome to preset 8 following 5 minutes of inactivity. This can be disabled by removing the link fitted across J6/pin  
4 & 5 and refitting to J6/pin 3 & 4.  
Privacy zone programming.  
Link J6/1-2 must be fitted to allow programming of privacy zones.  
– The keystrokes shown assume use of a TX1500. Use the keystroke shown above if using another controller.  
Programming a zone  
The Rx100 can be used to program 16 privacy zones, 100 – 115. The same procedure that is used to program a preset position is used to program or clear a  
privacy zone. To instruct the Rx100 to program privacy press 2# followed by program preset 1 – 16. The screen will then go blank showing that the privacy  
zone has been set.  
Clearing a zone  
To clear/delete a privacy zone press 3# followed by program preset 1 – 16. The relevant privacy zone will then be disabled.  
Mono/Colour switching  
If manual mono/colour switching is required then link J6/1-2 must be removed. This will disable the privacy zone set/clear features.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx 100 Interface Receiver  
Addendum to manual for the following domes:  
Vicon Surveyor 2000 dome.  
Rx100 software RX1_V2V9  
Application Notes  
The RX 100 provide the following functionality when controlling the above dome.  
Variable speed Pan/Tilt.  
Zoom/Focus, Autofocus with manual override.  
16 full scene presets (additional presets available using dome's menu)  
2 preset patrols  
4 alarm inputs driving to preset 1 - 4.  
Additional commands:  
RUN TOUR 80.  
Pressing the AUTOPAN key will start the dome's Tour 80. The tour is programmable using the dome's menu and allows a  
complex preset patrol, autopan or auto tour to be programmed. Refer to the dome programming manual for exact details.  
Advanced Menu Feature  
*Dome Menu – Store preset 94  
(also AP once in menu)  
AI (used as escape in menu)  
AUX1  
Tx1500 Tx1000  
Tx400DC  
'#' 1  
DM Mux  
*889 002  
1 ‘#’  
'#' WASH  
2 ‘#’  
3 ‘#’  
4 ‘#’  
'#' WIPE  
'#' AUTOPAN '#' 3  
'#' LIGHTS '#' 4  
'#' 2  
*889 003  
*889 004  
*889 005  
AUX2  
*Link J6/pin 1-2 must be fitted to access dome menu. Removing link will disable dome menu. On first entering the menu, the  
dome may autopan and/or access the pan/tilt menu. This is acceptable and simply pressing the AI function will allow the main  
menu to be displayed.  
RS485 control of dome using the following connections:  
Rx100  
J3-C1  
J3-C2  
Description  
TX/RX-  
TX/RX+  
Dome Interface Board  
COMM IN-  
COMM IN+  
Notes:  
The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.  
If the dome's tour 80 is running, start patrol 1 & 2 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, the  
tour will restart. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until the next manual pan command.  
Accessing the dome menu.  
Press '#'1 to display menu. Use pan/tilt keys or joystick to move cursor. '#'1 now acts as the AP key and '#'2 as the AI key as described on screen. ‘#’3 and  
‘#’4 are used as AUX1 and AUX2 during menu programming.  
Presets positions greater than 17 can be programmed using the dome's menu. These can be built into Tour 80 which is started by pressing the AUTOPAN key.  
Please refer to dome manual for specific instructions.  
IMPORTANT:  
Dome switch settings: S1 selects dome address, please set to address 2, S1/2=ON others OFF.  
S2 is used to select control method and video standard. Set to VPS with S2/2=OFF. (SW2 all OFF)  
For older versions of dome that do not support auto baud rate detect ensure that baud set for 9600.  
Please check Vicon manual to confirm switch settings.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following domes:  
Videcon Dome  
Rx100 software RX1_V4V2  
Application Notes  
The RX 100 provide the following functionality when controlling the above mentioned dome  
Variable speed Pan/Tilt.  
16 Full scene presets.  
2 RX100 preset patrols.  
Pattern Tour 1 learn and playback using AUTOPAN  
Privacy zone support  
IR Filter CUT using LIGHTS is link J6/1-2 fitted. Lights ON = FILTER OFF, Lights OFF = FILTER ON  
Advanced Features  
Display MENU  
Display Privacy Menu  
Record Pattern Tour 1  
Stop Recording  
Tx400 Tx1000  
Tx1500  
1 ’#’  
2 ’#’  
DM DS/DS2/BX2 Mux  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
*889 005 or *889 10 10 5  
‘#’ 1  
‘#’ 2  
‘#’ 3  
‘#’ 4  
'#' WASH  
'#' WIPE  
'#' AUTOPAN 3 ’#’  
‘#’ LIGHTS 4 ‘#’  
Pattern Tour 1 playback = press AUTOPAN  
The dome and Rx100 are linked using RS485 for control and video for the camera signal.  
Rx100  
J3-C1  
J3-C2  
Description  
TX-/B  
TX+/A  
Dome connection  
D-  
D+  
Notes:  
The dome switches must be as follows to select Pelco P, 9600 baud and address 1.  
SW1, 1 ON, 2-7 OFF. SW2, 1 & 2 ON, Protocol switch 1-4 all OFF  
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.  
When navigating the dome’s menu or privacy setup use the joystick and IRIS OPEN and CLOSE.  
The dome manual has detailed information on the menu structure and privacy setting.  
J6 Links  
J6/1-2 fitted to allow LIGHTS to switch the IR CUT filter ON/OFF when used with a day/night dome.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following camera:  
Videcon VCP451 Camera  
Rx100 software RX1_V5V1  
Application Notes  
The RX 100 provides control of Zoom and Focus and Menu Access.  
Advanced Features  
Display MENU  
Tx400 Tx1000  
‘#’ 1 '#' WASH  
Tx1500  
1 ’#’  
DM DS/DS2/BX2 Mux  
*889 002 or *889 10 10 2  
The camera and Rx100 are linked using RS485 for control and video for the camera signal.  
Rx100  
J3-C1  
J3-C2  
Description  
TX-/B  
TX+/A  
Camera connection  
RS485-  
RS485+  
Notes:  
Before controlling from the RX100 please enter the camera menu using the MENU button and set the following:  
CAMERA ID – 001  
PROTOCOL – P/D  
(The Rx100 uses PELCO D, 2400,N,8,1 to drive this camera)  
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.  
To allow easy navigation in the camera menu the pan and tilt functions generate zoom and focus commands even when not  
displaying the camera menu. This is NOT a fault!  
To aid with confirming correction connection and operation fitting the TEST link to make the camera ZOOM IN and remove  
to make the camera ZOOM OUT. If this is fine then the RX100 and camera are communicating correctly.  
The camera manual has detailed information on the menu structure and privacy setting.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBV Rx100 Interface Receiver  
Addendum to manual for the following domes:  
Vista PowerDome  
Rx100 software RX1_V3V2  
Application Notes  
The RX 100 provide the following functionality when controlling the above mentioned dome  
Variable speed Pan/Tilt.  
Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out.  
16 Full scene presets.  
2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 02)  
Learned tour playback using AUTOPAN key.  
5 minute datum/park driving to preset 1 or dome’s TOUR 2. Disabled by removing link J6/1-2  
Program up to 16 privacy zones  
Advanced Features  
Display MENU  
ENTER in MENU  
ESC in MENU  
Tx400 Tx1000  
Tx1500  
1 ’#’  
2 ’#’  
DM DS/DS2/BX2 Mux  
*889 002 or *889 10 10 2  
*889 003 or *889 10 10 3  
*889 004 or *889 10 10 4  
‘#’ 1  
‘#’ 2  
‘#’ 3  
'#' WASH  
'#' WIPE  
'#' AUTOPAN 3 ’#’  
The dome and Rx100 are linked using RS485 for control and video for the camera signal.  
Rx100  
J3-C1  
J3-C2  
Description  
TX-/B  
TX+/A  
Dome connection  
RS485 B -  
RS485 A +  
Notes:  
The dome address must be set at 1 for all the cameras that are controlled using a Rx100. Check with the dome manual if you  
have any doubts.  
The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.  
If the learned tour playback is running, start patrol 1 is inhibited. The dome will be driven to a preset following an alarm  
activation. 60 seconds after alarm, the learned tour will restart. A manual goto preset and lens control will stop the tour  
leaving the AUTOPAN led on until the next manual pan command.  
J6 Links  
J6/1-2 fitted to enable the 5 minute datum mode. After 5 minutes of inactivity the dome will be driven to either preset 1 or the  
dome’s TOUR 2 is started depending upon link J6/3,4,5. J6/4-5 fitted = goto preset 1, J6/3-4 fitted = start dome TOUR 2.  
The dome’s TOUR 2 must be programmed from within the domes menu. Please refer to the dome manual for details.  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B - Trouble shooting guide.  
Symptom: No video from interface.  
Possible causes:  
Camera is not powered or not connected to ‘CAMERA’ BNC on interface.  
Check power and cabling.  
Interface is not powered.  
Check power.  
Video out not connected to ‘TELEMETRY’ BNC on interface.  
Check cabling.  
If the after following the above check list video still not present then remove both BNCs from the interface  
and connect together using a female/female barrel connector to check video path from camera to control  
point.  
Symptom: No camera control but lights relay operates with LIGHTS key on transmitter.  
Possible causes:  
Dome data cable is not connected correctly.  
Check cabling, most commonly due to data cables swapped.  
Dome configuration switches if fitted not set correctly.  
Check configuration.  
Symptom: No camera control and lights relay not operating.  
Possible causes:  
Interface not seeing Telemetry signal.  
Check that telemetry is present on video cable using either oscilloscope or adjust v.hold on monitor to  
view frame blanking period and check for black/white band. If missing, power down/up the transmitter.  
Should this fail, swap video between working and non-working channels.  
Earth loops can interrupt telemetry operation if sufficiently severe.  
If hum bars are apparent, fit isolation transformer to coaxial cable.  
Check cable and error LEDs on interface.  
See SETUP section earlier in this manual for correct indication.  
If the problem persists having followed the above steps, technical assistance can be received from  
Building Block Video. Tel: +44 (0)1323 444600  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
--- Blank for your notes ---  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Other BBV products.  
Product Description  
Single camera desktop telemetry transmitter with BBV up-the-coax &  
20mA telemetry, Pan/Tilt/Lens & Lights  
TX300  
TX400  
TX400DC  
As TX300 inc Wash, Wipe, Autopan, 8 presets, preset patrol.  
As TX400 including joystick for proportional Pan/Tilt control.  
8 or 16 camera, 2 monitor telemetry transmitter. Up to 2 keyboards.  
BBV up-the-coax and RS422 standard with options for alarm inputs  
and 20mA telemetry.  
Mid size matrix 16 – 96 camera, 8 monitor. Up to 4 control positions  
(keyboard & remote control) options for alarms, remote control, BBV  
up-the-coax and RS485 telemetry.  
Large size matrix. Configurable up to 4096 cameras and 64 monitor  
outputs. Up to 8 control positions (keyboard & remote control) options  
for alarms, remote control RS485 telemetry with various options.  
Please call to discuss requirements.  
TX1000 MK2  
TX1500  
FBM range  
Dome Interface with options to drive a large library of dome cameras.  
BBV up-the-coax and 20mA telemetry.  
RX100  
RX200  
RX300  
RX400P  
AC receiver for Pan only heads or static cameras, Wash/Wipe/Lights.  
BBV up-the-coax and 20mA telemetry.  
AC receiver for Pan/Tilt/Zoom/Focus/Iris Override and 1 Auxiliary  
output. BBV up-the-coax and 20mA telemetry.  
AC full function receiver. PTZFI 4 Auxiliary outputs, 16 presets. BBV  
up-the-coax and 20mA telemetry.  
Multiple RS485/422 and BBV up-the-coax controllable AC and DC  
receivers. These receivers are controlled from an expanding range of  
serial protocols as listed below. 110/230Vac supply. PTZFI, 64 presets,  
preset patrol, 8 local alarm inputs, 12V 500mA supply output. OSD for  
remote diagnostics. 3 Aux. outputs RX55X or 4 Aux. outputs RX45X.  
Optional Privacy board.  
RX45X (AC)  
RX55X (DC)  
BBV RS485 and COAX,  
PELCO P/D RS485,  
VCL/HONEYWELL RS485,  
PHILIPS/BOSCH RS485 (OPTIONAL BI-PHASE INPUT),  
DENNARD RS485  
SENSORMATIC/AD RS422  
Multi RS485 protocol  
and BBV up-the-coax  
telemetry receivers  
PANASONIC RS485 Protocol only version of RX45X/55X.  
RX450/550  
8 * RS485 output, 2 wire simples RS422, 4 wire full-duplex RS422, 2  
wire half-duplex RS485.  
STARCARD  
Optional STARCARD/CONVERTER offering protocol conversion to  
drive an increasing range of 3rd party protocols.  
STARCARD/CONVERTER  
CTI/16 16 camera, RS422 to up-the-coax converter  
TxLD (bidirectional RS422-RS232 converter)  
98005 (bidirectional 20mA-RS232 converter)  
AD RS422 (American Dynamics) protocol converters  
ACCESSORIES  
Rx100 installation manual V1.17 29 Aug 08.doc  
Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Projector XV Z200E User Manual
Snapper Lawn Mower Accessory 1694693 User Manual
Sony Clock Radio FX483 User Manual
Sony Indoor Furnishings WS FV10D User Manual
Sony MiniDisc Player MDX CA680 User Manual
Sony Projector CX125 User Manual
Sony Speaker XS W3521 User Manual
Sterling Plumbing Outdoor Shower 72260100 User Manual
SVAT Electronics Home Security System CLEARVU6 User Manual
SV Sound Speaker 16 46PCi User Manual