AUDIO MONITOR SPEAKER SYSTEM
AMS-100
ANALOG MODULE
BKAM-101
AES/EBU MODULE
BKAM-102
SDI MODULE
BKAM-103
INSTALLATION MANUAL
1st Edition
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1. Installation
1-1. Power Supply ........................................................................................1-1 (E)
1-1-1. Power Specifications ............................................................1-1 (E)
1-1-2. Power Cord...........................................................................1-1 (E)
1-2. Dimensions............................................................................................1-2 (E)
1-3. Installation of Boards ............................................................................1-2 (E)
1-4. Rack Mounting......................................................................................1-3 (E)
1-5. Pin Assignment of Connectors..............................................................1-4 (E)
1-6. Matching Connectors and Cables..........................................................1-5 (E)
1-7. Internal Switches ...................................................................................1-5 (E)
1-7-1. AL-42 Board (BKAM-101) .................................................1-5 (E)
1-7-2. SDI-43 Board (BKAM-103) ................................................1-5 (E)
1-8.
Input Level Meter Adjustment .............................................................1-6 (E)
1-9. Related manuals ....................................................................................1-6 (E)
Section 1
Installation
1-1. Power Supply
Power code for the customer in the U.S.A.and Canada.
1 Power cord (approx. 2.4 m) ! 1-557-377-11
2 Plug holder (Black)
2-990-242-01
1-1-1. Power Specifications
AC inlet
1
2
Power voltage
AC 100 to 240 V ±10 %
Current consumption 25 W
Inrush current
20 A
Power code for the customer in the United Kingdom.
1 Power cord set (approx. 2.4 m) ! DK-2401 (UK)
2 Plug holder (Black) 2-990-242-01
Plug holder is supplied with DK-2401 (UK).
1-1-2. Power Cord
AC inlet
1
2
w
Use the specified power cord only when connecting.
Never use a injured power cord.
n
Ground the unit safely.
Power code for the customer in Europe except the United
Kingdom.
1 Power cord set (approx. 2.4 m) ! DK-2401 (AE)
2 Plug holder (Black)
2-990-242-01
If the unit is used in the area except above, please consult
with local Sony’s sales/service office.
Plug holder is supplied with DK-2401 (AE).
AC inlet
2
1
AMS-100
1-1(E)
Download from Www.Somanuals.com. All Manuals Search And Download.
1-2. Dimensions
1-3. Installation of Boards
1-2. Dimensions
424
465
482
Unit : mm
1-3. Installation of Boards
The optional boards (BKAM-101/102/103) can be installed in any slots of the AMS-100.
Installation of optional boards
1. Turn off the power of the AMS-100.
2. Remove the blank panel on the rear panel after
removing its two retainer screws.
n
Do not discard the removed blank panel.
Blank panel
3. Slide the optional board along the guide rails into the
unit.
4. Secure the optional board in the AMS-100 with the
screws supplied with the optional board.
n
B 3x5
If there is any unused slot without a cover, install the
cover you have just removed there.
B 3x5
BKAM-101, BKAM-102, BKAM-103
AMS-100
1-2(E)
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Rack Mounting
1-4. Rack Mounting
Procedures
The AMS-100 can be mounted in a 19-inch standard rack.
1. Turn off the power.
2. Attach the inner rails to the unit using the six screws
n
(B4x8) supplied with the RMM-30.
. If the AMS-100 or the peripheral equipment is mounted
in a 19-inch standard rack, it is recommended to install a
ventilation fan to prevent a temperature rise in the rack.
Make sure that all the units in the rack should be operat-
ed within the temperature range of 5dC to 40dC.
. Connect the enough long cables on the rear panel,
considering that the AMS-100 is pulled out.
. Be sure to fix the rack to the floor with bolts.
This will prevent the rack from falling when the unit is
pulled out from the rack.
Inner rail
B 4x8
Inner rail
B 4x8
Required parts
. Rack mount rail (RMM-30)
Rail with bracket
Screw (B5x8)
Screw (PWH4x10)
Plate nut
3. Temporarily fix the front and rear brackets to the rack
by running in but not tightening the four screws
(B5x8) and two screws (PWH4x10) supplied with the
RMM-30.
: 2 pcs.
: 4 pcs.
: 2 pcs.
: 2 pcs.
: 6 pcs.
. Screw for inner rail (B4x8)
Plate nut
. Screw for rack mounting (RK5x16) : 4 pcs.
. Washer for rack mounting
: 4 pcs.
(Sony part number : 2-297-913-00)
Rack
12.7
15.9
c
Be sure to use the RMM-30 rack mount rail.
15.9
12.7
If a rack mount rail other than the RMM-30 is used, the
AMS-100 may be dropped by insufficient strength of the
rack mount rail. This may cause a injury.
Front bracket
15.9
15.9
PWH 4x10
B 5x8
Rear bracket
31.75
_To be continued on the next page._
AMS-100
1-3(E)
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Rack Mounting
1-5. Pin Assignment of Connectors
4. To mount the unit on the rack, while pressing the
stoppers of the inner rails, slide the inner rails fully
into the outer rails.
1-5. Pin Assignment of Connectors
REMOTE (D-sub 25-pin, Female)
5. After confirming that the unit can be moved smoothly,
tighten the six screws run in but not tightened in
procedure 3.
13
1
25
14
n
To tighten the front brackets to the rack, slide the unit
from the rack toward you about 20 mm.
6. After mounting the unit on the rack, fix the unit to the
rack with the four screws (RK5x16) and four washers.
_External View_
Pin No.
Signal
1
REM-A IN
REM-B IN
2
3
REM-CH.SELECT L1 IN
REM-CH.SELECT L2 IN
REM-CH.SELECT R1 IN
REM-CH.SELECT R2 IN
GND
4
5
6
7
Washer
8
MONITOR OUT 2(H)
MONITOR OUT 2(C)
MONITOR OUT 1(H)
MONITOR OUT 1(C)
REM-GROUP SEL. 1 IN
REM-GROUP SEL. 2 IN
STS-A OUT
9
RK 5x16
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Outer rail
Stopper
RK 5x16
Inner rail
Washer
STS-B OUT
STS-CH. SELECT L1 OUT
STS-CH. SELECT L2 OUT
STS-CH. SELECT R1 OUT
STS-CH. SELECT R2 OUT
STS-GROUP SEL. 1 OUT
MONITOR OUT 2(G)
REM-ENABLE 2 IN
MONITOR OUT 1(G)
STS-GROUP SEL. 2 OUT
REM-ENABLE 1 IN
AMS-100
1-4(E)
Download from Www.Somanuals.com. All Manuals Search And Download.
1-6. Matching Connectors and Cables
1-7. Internal Switches
1-6. Matching Connectors and Cables
1-7-2. SDI-43 Board (BKAM-103)
When connecting cables to various connectors on the rear
panel at the time of installing or servicing, connect the
following connectors/cables or their equivalents.
CN101
Connector
Matching Connector/cable
Connector/Cable
Panel indication
Sony Part No.
S101
S102
REMOTE
D-sub 25-pin, male
1-566-356-11
AUDIO IN 1
XLR 3-pin, male
XLR 3-pin, female
1-508-084-00 (*1)
1-508-083-00 (*2)
S103
AUDIO IN 2
XLR 3-pin, male
XLR 3-pin, female
1-508-084-00 (*1)
1-508-083-00 (*2)
DIGITAL AUDIO IN
XLR 3-pin, female
BNC 75 Z, male
5C-2V cable (*3)
1-508-083-00 (*2)
1-560-370-12
SDI IN
SDI OUT
BNC 75 Z, male
5C-2V cable (*3)
1-560-370-12
(*1) : ITT Cannon XLR-3-12C or equivalent
(*2) : ITT Cannon XLR-3-11C or equivalent
(*3) : 5C-2V coaxial cable (max. 200 m)
S101 : Free-run adjustment select switch for the
serial decoder
It is recommended to use the 5C-2V coaxial cable made by Fujikura
America Inc./Fujikura Europe Ltd. (FEL) or equivalent.
Used during free-run adjustment of the serial decoder:
OFF :
ON :
Factory setting : OFF
Normal operation
For free-run adjustment
1-7. Internal Switches
1-7-1. AL-42 Board (BKAM-101)
S102 : Video system select switch
To select the video system (525/625).
(Effective for 4:2:2 component serial video signal mode)
CN101
525 :
625 :
For a 525 video system
For a 625 video system
Factory setting : 525
S2
S22
S103 : Mode select switch
ON
(
Indicates the switch lever position.)
1
2
3
4
S103-1 :
D1/D2 system selector
To select the video system used:
OFF (D1) : 4:2:2 component serial video signal
ON (D2) : 4fsc composite serial video signal
S103-2, -3, -4 : For factory-adjustment use only.
n
S2: CH-1 input level select switch
To select the input level of CH-1.
Factory setting : +4 dB
Do not change the factory presetting of
these switches.
Factory setting : all OFF
S22: CH-2 input level select switch
To select the input level of CH-2.
Factory setting : +4 dB
AMS-100
1-5(E)
Download from Www.Somanuals.com. All Manuals Search And Download.
1-8. Adjustment of the Input Level Meter
1-9. Related manuals
1-8. Input Level Meter Adjustment
1-9. Related manuals
Besides this Installation Manual, the following manuals are
available for the AMS-100.
Preparation
. Input the reference signal to the unit:
When the BKAM-101 is attached : +4 dBm
When the BKAM-102 is attached : _20 dB FS
. Turn on the power of the unit and select the slot and the
channel to which the reference signal is to be input on
the INPUT SELECT operation panel.
(For details on operation, refer to the Operation Manual.)
. Let the unit warm up for about 10 minutes.
. Operation Manual (Supplied with the AMS-100)
This manual explains the overview of the AMS-100, and
the system configuration examples.
. Maintenance Manual (available on request)
This manual describes information that premise the
service based on parts replacement (adjustments, board
layouts, schematic diagrams, parts list, etc.).
If this manual is required, contact your local Sony Sales
Office/Service Center.
Adjustment procedures
1. Press and hold the button corresponding to the desired
slot for 3 seconds or more on the INPUT SELECT
operation panel to enter Adjustment mode.
2. Check that the LED for the channel you are selecting
starts blinking.
3. Perform the following adjustment.
Adj. point :
Adjustment screw L/input level meter
Adjustment screw R/input level meter
Specification : The LEDs for “0” level start blinking.
LEDs for "0" level
L
R
+3
+1
+3
+1
0
0
_1
_1
_3
_3
_5
_5
_7
_7
_10
_15
_20
_10
_15
_20
Adjustment screws
Setting after adjustment
To return from Adjustment mode, press any button on the
INPUT SELECT operation panel.
AMS-100
1-6(E)
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY CHECK-OUT
After correcting the original service problem,
perform the following safety checks before
releasing the set to the customer :
Check the metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC
leakage. Check leakage as described below.
The material contained in this manual consists of
information that is the property of Sony Corporation and
is intended solely for use by the purchasers of the
equipment described in this manual.
Sony Corporation expressly prohibits the duplication of
any portion of this manual or the use thereof for any
purpose other than the operation or maintenance of the
equipment described in this manual without the express
written permission of Sony Corporation.
LEAKAGE TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to
any exposed metal part having a return to
chassis, must not exceed 3.5 mA. Leakage
current can be measured by any one of three
methods.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Corporation et
sont destinées exclusivement à l’usage des acquéreurs
de l’équipement décrit dans ce manuel.
Sony Corporation interdit formellement la copie de
quelque partie que ce soit de ce manuel ou son emploi
pour tout autre but que des opérations ou entretiens de
l’équipement à moins d’une permission écrite de Sony
Corporation.
1. A commercial leakage tester, such as the
Simpson 229 or RCA WT-540A. Follow the
manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The
Data Precision 245 digital multimeter is
suitable for this job.
3. Measuring the voltage drop across a resistor
by means of a VOM or battery-operated AC
voltmeter. The “limit” indication is 5.25 V, so
analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa
SH-63Trd are examples of a passive VOM
that is suitable. Nearly all battery operated
digital multimeters that have a 20 V AC range
are suitable. (See Fig. A)
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind,
und ausschließlich zum Gebrauch durch den Käufer der
in dieser Anleitung beschriebenen Ausrüstung bestimmt
sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als
die Bedienung oder Wartung der in dieser Anleitung
To Exposed Metal
Parts on Set
beschriebenen
Ausrüstung
ohne
ausdrückliche
schriftliche Erlaubnis der Sony Corporation.
AC
voltmeter
(5.25V)
0.15 µF
1.5 kZ
Earth Ground
Fig A. Using an AC voltmeter to check AC leakage.
Download from Www.Somanuals.com. All Manuals Search And Download.
AMS-100 (SY)
BKAM-101 (SY)
BKAM-102 (SY)
BKAM-103 (SY) J, E
3-202-309-01
Printed in Japan
1999. 2 11
©1999
Sony Corporation
Broadcasting & Professional Systems Company
Download from Www.Somanuals.com. All Manuals Search And Download.
|