ADDRESS:
Soleus International, Inc.
20035 E. Walnut Dr. N.,
City of Industry, CA 91789
WEBSITE:
TEL:
(888) 876-5387
SG-DEH-70EP-2 (DP2-70EP-03)
Portable Dehumidifier with External Pump
Operating Instructions
V.130424
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
SAFETY INSTRUCTIONS
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
IMPORTANT CAUTIONS FOR USING YOUR DEHUMIDIFIER.
To reduce the risk of fire, electrical shock, injury, or damage to the
dehumidifiers, these safety precautions must be followed:
Safety
• Do not remove plug from outlet by pull-
ing on the cord.
• Do not place the power cord near a heater.
• Do not use an electrical outlet near flam-
mable or combustible materials such as
gasoline, propane, paint thinners, etc.
• Do not disassemble or modify dehumidifier
parts or components. It may cause electric
shock and failure.
• When not in use, turning the unit off will
save energy. Unplug the dehumidifier
when not using for long periods of time.
• When removing the filter, be aware that
some metal parts may have sharp edges
and may cause injury.
• Plug in the power cord properly.
• Do not turn the unit on and off by inserting
or pulling out the power plug.
• Do not damage the power cord or use an
unspecified power cord.
• Do not use the water collected in the
bucket for drinking purposes. It is not
sanitary and could cause illness.
• Do not allow children to play with this
product.
• Do not modify power cord length.
• Do not share the outlet with another appli-
ance.
• Always plug into a grounded outlet. Not
grounding unit may cause electrical shock.
• Unplug the unit if it emits strange sounds,
odors, or smoke.
• Do not use an electrical outlet if it is loose
or damaged.
• Do not operate or plug in unit with wet
hands or in a wet environment.
• Ventilate area before operating dehumidi-
fier. Check for the presence of natural gas
or the buildup of other combustible vapors.
• Do not clean the dehumidifier with water.
Water may enter the unit and degrade the
insulation resulting in an electrical shock.
• If water enters the product, turn off the
dehumidifier's power switch, then unplug
the unit. Do not plug in unit until it has been
inspected by an authorized repair service.
• Because the fan rotates at high speed dur-
ing operation, always unplug dehumidifier
before attempting any recommended main-
tenance or cleaning.
Tips
• Make sure the dehumidifier is the correct
size for the area you want to dehumidify.
It is not designed to dehumidify the entire
house.
• For proper operation, the dehumidifier
should only be placed on a level floor.
• Close all doors, windows and other open-
ings to the room. The dehumidifier must
operate in an enclosed area to be effec-
tive.
• To clean, use a soft cloth; do not use
wax, thinners, or strong detergents as
they may change the color of the unit or
cause surface damage.
• Be sure to replace the bucket properly
after emptying to prevent water from
collecting on the floor causing damage to
some types of flooring.
• Do not put a pet or house plant where it
will be exposed to direct air flow. This
could injure the pet or plant.
• Operation without filter will cause unit
failure. Insert the filter securely. Clean it
every two weeks. (See Care and Mainte-
• Do not block the inlet or outlet. It may
cause
unit to fail or to operate inefficiently.
nance section in this manual.)
18
3
Download from Www.Somanuals.com. All Manuals Search And Download.
EXTERNALVERTICALPUMP
ELECTRICAL REQUIREMENTS
OBSERVE ALL LOCAL CODES AND ORDI-
NANCES.
RECOMMENDED GROUNDING
METHOD
Pump capacity per 24 hours
304 pints per day
For your personal safety, this appliance
must be grounded. This appliance has a
power supply cord with a 3-prong
grounded plug. To minimize possible shock
hazard the cord must be plugged into a
matching grounded electrical outlet that
complies with the latest edition of the
National Electrical Codes and all local
codes and ordinances.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.
Vertical Height Pumping
Power Source
16 ft.
115 V / 60 HZ
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE
Rated Current (Amps)
.12A
A 115-VOLT 60Hz, AC ONLY, 15A FUSED
AND PROPERLY GROUNDED ELECTRICAL
SUPPLY IS REQUIRED.
If a grounded 3-prong electrical outlet is
not available, it is the personal responsibil-
ity and obligation of the customer to have
one installed by a qualified electrician.
Dehumidifier Drain Hose Diameter
Pump Drain Hose Inside Diameter
.50 in. / 13 mm
.20 in / 5 mm
A time delay fuse or time delay circuit
breaker is recommended. Use a dedicated
WARNING
3-prong grounded plug
ELECTRICAL SHOCK HAZARD
• Plug into a grounded 3-prong outlet.
Power supply cord
• Do not remove the ground pin from the
plug.
Grounded 3-prong
electrical outlet
circuit serving only
this appliance.
• Do not use an adapter.
• Do not use an extension cord.
• Failure to follow these instructions can
result in death, fire or electrical shock.
INSTALLING YOUR DEHUMIDIFIER
DEFROST OPERATION
• Install the dehumidifier on a level floor
strong enough to support the unit with a
full bucket of water.
• For best performance, allow at least 12-18
inches of air space on all sides of the unit
for good air circulation.
The dehumidifier has a built-in defrost
control that senses frost buildup on the
evaporator coils.
During defrosting, the compressor will
automatically turn off; the fan will continue
running to defrost the coils.
• Keep all outside doors, windows and other
openings closed when operating the dehu-
midifier. Humid outdoor air will add to the
unit's workload.
• Leave the dehumidifier in an upright posi-
tion for 30 minutes before turning on.
17
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CHOOSING THE PROPER LOCATION
Use the dehumidifier:
AUTOMATIC SHUT OFF
ERROR CODES
•
•
•
When the bucket is full, or when the
bucket has been removed, the compres-
sor will automatically stop. The fan will
continue to run to dehumidify for 3 min-
utes. Then the Bucket Full indicator will
flash and you will hear a ten second
audible alarm.
• in the basement to help prevent moisture
Error Type
Possible Cause
Corrective Action
Error Code
F1
damage.
• in the kitchen, laundry room, bathroom,
and spa/exercise areas that have exces-
sive moisture.
Ambient Tem- 1. Sudden Change in 1. Unplug the dehumidifier.
The bucket must be placed in the proper
position for the dehumidifier to work.
The Bucket Full light will flash and the
dehumidifier will not run if the bucket is
not in the proper position. Dehumidifier
settings can not be changed when the
bucket is not in its proper position.
perature Sensor
Malfunction
the surrounding
temperature.
2. Check the surrounding area for
possible reasons for sudden
temperature changes.
• to prevent moisture damage anywhere
books or valuables are stored.
3. Wait 30 minutes before plug-
ging the dehumidifier back in
for normal operation.
4. If the “Error” is still indicated,
please contact your nearest
service center. Call (888) 876-
5387 for service center
• during construction or remodeling to
reduce drying time for drywall and paint.
However, check and clean filter often.
2. Faulty Sensor
F2
Pipe
perature
Tem-
The dehumidifier fan will shut off in 3
minutes, once the desired
Sensor Mal-
function
humidityset-
ting is reached plus or minus 5% Rela-
tive Humidity (RH).
locations.
WARNING
To reduce the risk of fire, electric shock or injury to persons, read the important SAFETY IN-
STRUCTIONS found on page 3 before operating this appliance.
PRODUCT SPECIFICATIONS
ITEM #
SG-DEH-70EP-2
KEY FEATURES
Reference Number
DP2-70EP-03
Washable Filter
Continuous Drain
Connector Door
Enclosure
70 Pints per day
(32.9 Liters per day)
Moisture Removal per 24 hours
Power Consumption (W)
745 Watts
Dehumidifier
Bucket Capacity
Power Source
17 Pints (8 Liters)
115 V / 60 HZ
Power Cord
16 ft. Pump
Drain Hose
Rated Current (Amps)
7.3A
3 ft.
Dehumidifier
Hose
Sound Pressure Level dB (L/M/H)
45/47/49 dB(A)
47.7
Bucket
Vertical
Pump
Weight
lbs
Power Cord
Dimensions (W x D x H)
15.125” x 11.5” x 24.125”
Caster
5
16
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING (Cont.)
CONTROL PANEL
(7)
(8)
(9)
(10) (11) (12) (13)
Problem
Possib
le Causes
Solutions
The capacity of your dehumidifier may
not be adequate for the room size.
The area to be dehumidified
is too large.
Dehumidifier runs too
much
Doors and windows are
open.
Close all doors and windows to the out-
side.
Frost appears on the
coils
The dehumidifier has recently
been turned on or the room
temperature is below 41°F.
is normal. Frost will usually disappear
within 60 minutes.
This
(6)
(1)
(3)
(4)
(5)
(2)
Bucket is full or it has been
removed.
Controls cannot be set
Empty bucket and install properly in unit.
This is normal.
)
POWER ON/OFF (1)
DELAY START (4
Once the unit is plugged in, the POWER INDICA-
TOR (10) will light. Pressing the POWER button
once will turn the unit ON and illuminate the digi-
tal display (9). The fan will operate for 3 minutes
to draw air through the dehumidifier to properly
sense relative humidity. The display will show the
humidity level of the room in 5% increments,
down to a minimum of 25%. Pressing the Power
button again will turn the display OFF and the
unit will cease operating.
Unit can be programmed to turn on at a desired
delay time by pressing the Timer (4) key. When
the unit is powered OFF, press the timer key once
for 2-hour delay start. The 2 Hrs (7) timer indica-
tor will light up when the timer key is pressed.
Press the timer key once more for a 4-hour delay
start. The 4 Hrs (7) timer indicator will now light
up. Press the timer key a third time to clear the
timer setting. No timer indicators will light up
when the timer setting is cleared.
Air is moving through the
unit.
Fan Noise
Check the hose connection. See the Drain-
age Section
Hose connection may be
loose.
Water on the floor
Disconnect the hose if using the bucket or
place the hose near a drain.
Hose is attached but not
draining into a drain
AUTO SHUT-OFF (4)
HUMIDITY LEVEL (2/3)
Normal: Compressor and electric motor
discharge nominal heat.
Unit is discharging
warm air
Unit can be programmed to turn off at a desired
time by pressing the Timer (4) key. When the unit
is powered ON, press the timer key once for 2-
hour automatic shut-off. The 2 Hrs (7) timer indi-
cator will light up when the timer key is pressed.
Press the timer key once more for a 4-hour auto-
matic shut-off. The 4 Hrs (7) timer indicator will
now light up. Press the timer key a third time to
clear the timer setting. No timer indicators will
light up when the timer setting is cleared.
The humidity level can be set in 5% increments in
a range from 35% to 80%. The humidity setting
is shown in the digital display. When the humid-
ity level of the room reaches the set level, the
compressor will stop, but the fan will continue
operating for 3 minutes. To set the unit to continu-
ous operation, press the "-" arrow button until
the display shows 35%. Press again and the dis-
play will show CO. The Continuous indicator (13)
will light up on the control panel. To leave con-
and
Re-install the dehumidifier drainage joint
and hose according to the manual.
Check the drainage joint
Water does not
drain through the
dehumidifier drain
hose
dehumidi-
hose on the
fier. Is it installed correctly?
Check the drain hose for
kinks or obstructions.
(2)
Flatten the hose or remove blockage.
tinuous operation, press the
"+" (3) arrow.
Re-install the pump drain hose according
to the manual.
Check the pump drain hose
on the pump. Is it installed
correctly?
FILTER RESET (12)
Water does not
drain through the
pump drain hose
To check the current humidity setting, press the
"+" and "-" arrow. The display will show and
set 5% above or below the current settings.
The FILTER RESET indicator (12) will light up when
the filter needs cleaning. Remove the filter and
clean accordingly. Replace the filter when fin-
ished and press and hold the FILTER (6) key up to
5 seconds to reset the filter indicator.
IMPORTANT:
Flatten the hose or remove blockage.
Check the pump drain hose
for kinks or obstruc-tions.
FAN SPEED (5)
Press Fan Speed to toggle between Low, Med,
and High fan speeds. Speed will be shown in FAN
SPEED INDICATOR (8)
•
Once the set humidity level is reached, the
compressor will shut off. The fan will con-
tinue to run for up to 3 minutes.
BUCKET FULL INDICATOR (11)
When the collection bucket is full, the BUCKET
FULL indicator (11) will light up and you will hear
an audible alarm. The audible alarm will last up
to ten seconds The dehumidifier will not run until
the bucket is removed, emptied and replaced.
•
Anytime the compressor stops running for
any reason, it will not restart for a minimum
of 3 minutes. This is a design feature to pro-
tect the compressor from damage.
15
6
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER DISPOSING OPTIONS
TROUBLESHOOTING
OPTION 1: EMPTYING MANUALLY
Problem
Possible Causes
Solutions
1. Pull out the bucket, grasping the side handles. (Fig. 1)
Dehumidifier does not
start.
The dehumidifier is un-
plugged.
Make sure the dehumidifier’s plug is pushed com-
pletely into the outlet.
2. Carry the bucket by grasping the front corner of the bucket with one hand and the back of
the bucket with the other hand( Fig. 2)
The fuse is blown / circuit
breaker is tripped.
Check the house fuse / circuit breaker box and
replace fuse or reset breaker.
3. Empty the bucket and replace the bucket in the dehumidifier. (Fig. 3)
NOTE: Dehumidifier will not work and settings can not be changed when the BUCKET FULL
indicator light is flashing or without the bucket properly installed.
Dehumidifier has reached
the user set humidity level
or the bucket is full.
The dehumidifier automatically turns off when either
condition occurs. Change to a lower setting or
empty the water bucket and replace properly.
DO NOT REMOVE THE STYROFOAM IN THE BUCKET
Bucket is not in the proper
position.
The bucket must be in place and securely seated for
the dehumidifier to operate.
This dehumidifier is equipped with a reliable Styrofoam float system. The Styrofoam
located inside the float in the bucket is essential to the bucket full system working
properly. Do not remove the Styrofoam from the float.
Power Failure.
There is a protective time delay of 3 minutes to
prevent tripping of the compressor overload. For this
reason, the unit will not start normal dehumidifica-
tion for 3 min. after it is powered back on.
Dehumidifier is not oper- Not enough time allowed When first installed, allow at least 24 hours to
ating as
for unit to remove moisture. achieve the desired humidity level.
Intended.
Airflow is restricted.
Make sure there are no curtains, blinds, or furniture
blocking the side or back of the dehumidifier.
Dirty filter.
See the Cleaning The Air Filter section
The user set Humidity Level To reduce moisture, press the down arrow button to
may not be set low enough. lower the percent humidity desired in the room, or
set the dehumidifier to CO for continuous operation.
(Fig. 1)
(Fig. 2)
Doors and windows may
not be closed tightly.
Check that all doors, windows, and other openings
are securely closed.
Water is not draining
through drain hose
Make sure the drain is placed below the drain con-
nector nozzle to allow gravity to drain the water
(Refer to Gravity Drain Hose section in this manual).
Room temperature is too
low.
Moisture removal is best at higher room tempera-
tures. Lower room temperatures will reduce the
moisture removal rate. This model is designed to
operate at temperatures above 41°F.
Filter Indicator is lit.
Filter needs to be cleaned
every 250 hours of use.
Once filter has been cleaned, press the FILTER but-
ton for 3 seconds to turn the filter indicator off.
(Fig. 3)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
14
INSTALLING THE GRAVITY DRAIN HOSE
CARE AND MAINTENANCE
Option 2: GRAVITY DRAIN HOSE
CLEANING THE AIR FILTER
After 250 hours of operation the FILTER
RESET indicator will light up to remind you to
clean and change the air filter.
WARNING
Step1: Open the drain connector door. (Fig. 6)
• Disconnect power supply cord from re-
ceptacle before performing any mainte-
nance.
It is recommended to periodically check the
filter for excess dirt even if the FILTER
RESET indicator is off.
1. To remove the air filter, press the two filter
tabs and pull the filter holder away from
the back of the unit.
CLEANING THE EXTERIOR
Clean the cabinet using a damp cloth and a
mild detergent. Do not use bleach or abra-
sives.
2. Remove the filter and clean with warm,
soapy water. Rinse and allow the filter to
dry before placing back in the unit.
3. Place the filter back into dehumidifier.
Plug unit back into outlet, power the unit
on and press and hold the FILTER key up
to 5 seconds on the control panel to reset
the filter setting.
CONTROL PANEL
Wipe down the control panel with a dry
cloth.
(FIG. 6)
CLEANING THE BUCKET
Every few weeks, clean the dehumidifier
bucket. Partially fill the bucket with clean
water and mild detergent. Swish the mixture
around in the bucket, empty and rinse. Re-
place the bucket when finished
Step Install and secure the drainage joint onto the drain connector. (Fig. 7)
2:
NOTE: DO NOT place the filter in a dish-
washer
CAUTION: DO NOT operate the dehumidi-
fier without a filter. Doing so may cause a
unit failure.
NOTE: Do not place the bucket in a dish-
washer.
FILTER TABS
(FIG. 7)
Step3: Place large hose clamp on the flat end of the dehumidifier drain hose. (Fig.
8)
(FIG. 8)
13
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING THE GRAVITY DRAIN HOSE
USING THE PUMP
4:
Step Insert the drain hose onto the drainage joint so that it is fully seated. (Fig. 9)
NOTE: Make sure the drain hose is lower than the horizontal plane of the drain on
the dehumidifier as seen in the illustration below. Drain hose should be as short as
possible and all kinks in the drain hose should be eliminated for proper pump opera-
tion.
3ft. Dehumidifier Drain Hose
(FIG. 9)
(FIG. 17)
Step 5: Secure hose by pushing large hose clamp towards the drainage joint. (Fig.
10)
NOTE: If you need to cut the dehumidifier drain hose, only cut on the flat end of the
hose. Do not cut the angled end as it is designed for insertion into the pump.
CUT
DO NOT CUT
(FIG. 10)
1. Remove flat end of the hose by squeezing the large clamp and pulling it to-
ward you.
2. Remove hose from drainage joint and cut hose to appropriate length.
3. Once cut is completed, refer to installing the Drain Hose to re-install dehu-
midifier drain hose.
Step 6: Place bucket in the dehumidifier for operation. (Fig. 11)
USING THE DRAIN PUMP
1. Plug into grounded electrical outlet.
2. Place the other end of the pump hose where you would like to empty the wa-
ter (floor drain, water container or through a basement window). The pump
will automatically start and begin pumping the water that drains into it. Check
hose for kinks or other obstructions.
3. Before and after each use, check hose connections to make sure they are
(FIG. 11)
properly secured.
9
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING THE EXTERNAL PUMP
INSTALLING THE EXTERNAL PUMP
OPTION 3: EXTERNAL VERTICAL PUMP
INSTALLING THE EXTERNAL PUMP
Step 4: Insert pump drain hose onto pump connector until it is
fully seated. Secure hose by pushing small clamp forward
towards the pump. (Fig. 14)
Step 1: To install Dehumidifier Drain Hose, refer to Gravity
Drain Using Dehumidifier Hose instructions starting on page 9.
Step 2: For optimal operation, it is recommended that the
pump is placed on a flat and level location. Attach the water
pump to a wall or other perpendicular flat surface with the
included screws for security. (Fig. 12)
(FIG. 14)
Step 5: Secure hose by pushing small clamp forward towards
the pump. (Fig. 15)
(FIG. 12)
Step 3: Remove red cap from drain hose connector on pump.
Attach the small drain hose clamp onto the pump drain hose.
(Fig. 13)
(FIG. 15)
Step 6: Insert the angled end of the dehumidifier drain hose
into the water pump tank. (Fig. 16).
(FIG. 13)
(FIG. 16)
11
10
Download from Www.Somanuals.com. All Manuals Search And Download.
|