Thank you for choosing a Soleus Air Powered by Gree Portable Dehumidifier. This owner’s manual  
will provide you with valuable information necessary for the proper care and maintenance of your  
new product. Please take a few moments to thoroughly read the instructions and familiarize yourself  
with all the operational aspects of your new Dehumidifier.  
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store  
name/location, date purchased, and serial number below:  
Store Name: ____________________________________________________  
Location: ______________________________________________________  
Date Purchased: _________________________________________________  
Serial Number (located on back of unit): ______________________________  
IMPORTANT INSTRUCTIONS  
Before installing and using your dehumidifier, please read this owner’s manual carefully. Store this manual in a  
safe place for future reference.  
1) Always place the unit on a level surface.  
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.  
3) Maintain at least 12-18 inches clearance space around this unit (at least 40” for the exhaust on the side). Do not  
block or cover air inlet or outlet grilles.  
4) The unit must be connected to a correctly grounded power supply.  
5) Do not start or stop the unit by inserting or pulling out the power plug.  
6) Do not use an adapter plug or extension cord.  
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.  
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.  
9) Do not let children play near this unit.  
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the  
manufacturer or a qualified service technician.  
11) When cleaning the unit, always turn the unit off and unplug the power cord.  
12) Keep the unit away from any potential fire hazard.  
13) Never put your hand inside the unit to prevent injury from the fan blades.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PACKAGE CONTENTS  
Portable Dehumidifier  
Operating Instructions  
SPECIFICATIONS  
Noise level is measured at a distance of 3.28 ft away from the front of the unit.  
Power consumption is measured when the fan runs at the highest speed setting.  
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.  
Model Number  
SG-DEH-70E-2  
Reference Number  
DP2-70E-03  
Dehumidifying Capacity  
70 Pints per day  
765 Watts  
Power Consumption  
(Watts)  
Air Flow Volume  
(High/Med/Low)  
208 / 191 / 156 CFM  
115 V / 60 HZ  
7.3A  
Power Source  
Rated Current (Amps)  
Sound Pressure Level  
(max)  
49 dB (A)  
Product Weight  
45.2 lbs  
Product Dimensions  
(W x D x H)  
15.125” x 11.5” x 24.125”  
Yes  
Energy Star  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROL PANEL & DIGITAL DISPLAY  
FILTER  
BUTTON  
TIMER BUTTON FAN SPEED  
BUTTON  
INCREASE/DECREASE  
ROOM HUMIDITY  
POWER  
BUTTON  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
OPERATING INSTRUCTIONS  
1) When first operating the dehumidifier, run it in Continuous mode for 24 hours.  
2) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER  
button once more to turn the unit off.  
3) Humidity Selection - Press the +or -buttons to choose the desired relative humidity in the room.  
Each press of the button will change the desired room humidity by 5%. The room humidity is selectable  
from 35%-80% or continuous. The unit will cycle on and off to maintain the humidity level chosen on the  
digital display. If you want the dehumidifier to operate continuously regardless of the room humidity, press  
the (-) buttons until you see “CO” on the digital display. This will enable continuous operation and the  
Continue” indicator will light up on the control panel.  
4) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High,  
Medium, and low. The fan speed can be visually distinguished by the fan speed indicators on the control  
panel.  
5) Timer - To program the unit to automatically turn off, press the TIMER button when the unit is on. You  
can select either 2 or 4 hours with the Timer. Once the desired time (2 or 4 hours) is over, the unit will  
automatically shut down.  
To program the unit to automatically turn on, connect the power cord without turning on the unit and  
press TIMER button to select either 2 or 4 hours. Once the desired time (2 or 4 hours) is over, the unit will  
automatically turn on.  
6) Bucket Full - When the water bucket is full of water, the unit will automatically shut off , make a beeping  
noise, and the Bucket Full Indicator will light up. The dehumidifier will not function until the water  
bucket is emptied and placed back inside the unit. The bucket should be cleaned every few weeks to pre-  
vent the growth of mold, mildew and bacteria. Use a mild detergent to clean the bucket. Once clean, com-  
pletely dry the bucket and place it back inside the dehumidifier.  
NOTE: Support bucket with  
both hands when emptying  
NOTE: When the bucket is full or removed from the machine, the compressor will turn off, but the fan  
will continue to run for a few minutes. This is completely normal. The dehumidifier will not be  
removing moisture from the air at this time.  
NOTE: When removing moisture from the air, the dehumidifier will exhaust warm air from the side  
exhaust vent.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
7) Clean Filter - When the filter needs to be cleaned the filter indicator will light up (after 250 hours of  
use). Remove the filter from the back of the unit by pressing the two buttons on top of the filter. Clean the  
filter with warm, soapy water. Dry thoroughly before replacing the filter. Once the filter is completely dry,  
place the filter back in the unit and press the FILTER button to reset the filter indicator.  
If the filter is torn or unusable, order a new filter by calling our customer service.  
CAUTION: DO NOT OPERATE THE DEHUMIDIFIER WITHOUT THE INCLUDED FILTER  
BUTTONS  
NOTE: Do not clean filter in dishwasher  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHOOSING A LOCATION  
A Dehumidifier operating in a basement will have little no effect in drying out an adja-  
cent enclosed storage area, such as a closet, unless there is adequate circulation of air  
in and out of the area.  
YES  
NO  
Above  
41° F  
Below  
41° F  
Do not use outdoors  
This dehumidifier is intended for indoor residential applications only. This unit  
should not be used for commercial or industrial applications  
Place the dehumidifier on a smooth , level floor surface that is strong enough to  
support the unit with a full bucket of water.  
Allow at least 12”-18” of air flow on all sides and at least 40” for the exhaust side.  
Place the dehumidifier in an area where the temperature will not fall below 41°F.  
The coils can become covered with frost at temperatures below 41°F, which may  
reduce performance  
Use the dehumidifier in cooking, laundry, bathing and dishwashing areas that have  
excessive moisture. NOTE: Place the dehumidifier away from a clothes dryer.  
Use the dehumidifier to prevent moisture damage anywhere books or valuables are  
stored.  
Use the dehumidifier in a basement to help prevent moisture damage.  
The dehumidifier must be operated in an enclosed area to be most effective.  
Close all doors, windows and other outside openings to the room.  
AUTOMATIC DEFROST  
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.  
When the coils is completely defrosted, the compressor or fan (depending on the model) will automatically restart and  
dehumidification will resume.  
CONTINUOUS DRAINAGE HOSE  
Water can be automatically emptied by attaching a hose to the continuous drainage port on the side of the dehumidifier. This will  
allow the unit to run continuously (depending on the selected humidity level) without having to empty the water bucket. To drain,  
simply attach a standard garden hose (not included). The thread standard for garden hoses in the US and its territories is known as  
GHT or "garden hose thread" which has an outer diameter of 1 1/16 inches (1.0625 inches or 27.0 mm) and a pitch of 11.5 TPI.  
Remove the bucket from the front of the unit.  
Open the drain cover on the side of the dehumidifier.  
Thread a garden hose (not supplied) onto the nozzle, cut to length and lead to the floor drain.  
Replace the bucket in the dehumidifier.  
NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.  
ATTENTION: When using continuous drainage option, place dehumidifier on a level surface and make sure garden hose  
is clear of any obstructions and is directed downward. Press down drain door so it rests on top of the hose.  
Placing dehumidifier on an uneven surface or improper hose installation may result in water filling up the  
bucket and causing the unit to shut off. Empty water bucket if shut off occurs, then check dehumidifier  
location and hose for proper setup.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Problem  
Possible Causes  
Solutions  
Dehumidifier does not start  
The dehumidifier is unplugged.  
Make sure the dehumidifier’s plug is pushed completely into  
the outlet.  
The fuse is blown / circuit breaker Check the house fuse / circuit breaker box and replace fuse or  
is tripped.  
reset breaker.  
Dehumidifier has reached its  
The dehumidifier automatically turns off when either condition  
present level or the bucket is full. occurs. Change to a lower setting or empty the water bucket  
and replace properly.  
Bucket is not in the proper  
position.  
The bucket must be in place and securely seated for the dehu-  
midifier to operate.  
Power Failure.  
There is a protective time delay (up to 3 min.) to prevent trip-  
ping of the compressor overload. For this reason, the unit may  
not start normal dehumidification for 3 min. after it is powered  
back on.  
Dehumidifier does not dry the Not enough time allowed for unit When first installed, allow at least 24 hours to maintain the  
air as it should  
to remove moisture.  
desired dryness.  
Airflow is restricted.  
Make sure there are no curtains, blinds, or furniture blocking  
the front or back of the dehumidifier. See the Choosing a Lo-  
cation section on Page .  
8
Dirty filter.  
See the Clean Filter section on Page .  
7
The Humidity Control may not be  
set low enough.  
For drier air, press the “-” button to lower the percent humid-  
ity desired in the room, or set the dehumidifier to CO for maxi-  
mum dehumidification.  
Doors and windows may not be  
closed tightly.  
Check that all doors, windows, and other openings are securely  
closed.  
Clothes dryer may be blowing  
moist air into the room.  
Install the dehumidifier away from the dryer. The dryer should  
be vented outside.  
Room temperature is too low.  
Moisture removal is best at higher room temperatures. Lower  
room temperatures will reduce the moisture removal rate. This  
model is designed to operate at temperatures above 41°F.  
Dehumidifier runs too much  
The area to be dehumidified is too The capacity of your dehumidifier may not be adequate for the  
large.  
room size.  
Doors and windows are open.  
Close all doors and windows to the outside.  
This is normal. Frost will usually disappear within 60 minutes.  
Frost appears on the coils  
Controls cannot be set  
The dehumidifier has recently  
been turned on or the room  
temperature is below 41°F.  
The compressor will turn off and This is normal. Wait approximately 3 minutes and set the fan  
the fan will automatically  
speed at the desired level.  
continue to run for approximately  
3 minutes at a fixed setting.  
Fan Noise  
Air is moving through the unit.  
Hose connection may be loose.  
This is normal.  
Water on the floor  
Check the hose connection. See the Drainage Section on Page .  
8
Hose is attached but not draining Disconnect the hose if using the bucket or place the hose near a  
into a drain  
drain.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
One Year Limited Warranty  
Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Dehumidifier to be free of defects in  
material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from  
the date of original retail purchase in the United States.  
If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of  
charge within a reasonable time after the unit is returned during the warranty period.  
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a  
copy of the original purchase invoice.  
THIS WARRANTY DOES NOT COVER:  
Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in  
material or workmanship.  
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions  
in the instructions.  
Damage to the finish of the case, or other appearance parts caused by wear.  
Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-  
tional Inc.  
Freight and Insurance cost for the warranty service.  
Filter and Accessories  
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO  
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.  
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT  
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR  
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.  
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-  
vaged, or refurbished products.  
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow  
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you  
specific legal rights, and you may also have other rights that vary from state to state.  
For Technical Support and Warranty Service  
Please Call (888) 876-5387  
Or Write To:  
Soleus International, Inc.  
20035 E. Walnut Dr. N.  
City of Industry, CA 91789 USA  
www.greeusa.com  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Microwave Oven R 21JCA User Manual
Silvercrest Coffeemaker SKAT1000A1 User Manual
Sony Camera Lens SEL35F28Z User Manual
Sony Cell Phone C2104BLK User Manual
Sony Portable CD Player D E341 User Manual
Sony Speaker System SRS TP1 User Manual
State Industries Electric Heater 40 DHMS User Manual
Sterling Compact Loader SSIL Series User Manual
Sungale Tablet ID982WTA User Manual
Sylvania TV VCR Combo 6620 LDF User Manual