Sales Inquiries: 800-934-9194
8,000 BTU Portable Air
Conditioner, Dehumidifier
and Fan
OWNER’S MANUAL
Model # MAC-8000
Please read owner’s manual carefully before operating unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Thank you for purchasing the Soleus Air MAC-8000 8,000 BTU Portable Air Conditioner and Dehumidifier. This unit is designed
to improve indoor living and working comfort by providing cooling, dehumidifying, and ventilation with minimal installation.
This multi-functional unit operates as an air conditioner, dehumidifier and fan. When operating as an air conditioner, this unit is
designed for spot cooling or cooling a room no larger than 150 square feet with a standard eight foot ceiling height. When using
this appliance, always exercise basic safety precautions.
Please complete the following information for future reference. Retain this owner’s manual with your sales receipt as a
permanent record of your purchase.
Serial Number: _________________________________________________________
Date of Purchase: _______________________________________________________
Place of Purchase: ______________________________________________________
IMPORTANT SAFEGUARDS
Before installing and using your portable air conditioner and heater, it is important that you read this owner’s manual
carefully. Store this manual in a safe place for future reference.
This instruction manual is used for guidance and does not form part of a contract. It reserves the right to make technical changes
without prior notice.
1. Always place the unit on a level surface.
2. The appliance shall be installed in accordance with national wiring regulation.
3. The unit must be connected to a correctly grounded power supply. For your safety, this unit is grounded through the
power cord plug when connected to a grounded wall outlet. Do not use an adapter plug or extension cord.
4. Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.
5. Do not apply an insecticide or any type of flammable spray on the unit.
6. Confirm drainage piping is connected properly.
7. Do not start or stop the unit by inserting or pulling out the power plug.
8. Do not operate with wet hands.
9. Close supervision is necessary when the unit is used near children. The unit in not intended for use by children.
10. Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.
11. Do not expose skin or eyes directly to cool air for a long period of time.
12. If an abnormal odor or smoke comes out of the unit, disconnect the unit immediately and contact a qualified service
technician. (see page 14)
13. When opening the filter cover, do not touch the metal parts in the unit’s interior.
14. Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate surroundings of a bath,
shower, or swimming pool, or in any other steamy, wet areas.
15. When cleaning the unit, always turn the unit off and unplug the power cord.
16. Always inspect the power cord for signs of damage before use. If the power cord is damaged, it must be replaced by the
manufacturer or a qualified service technician.
17. Do not place a plant or allow a pet in the direct path of the airflow to avoid injury.
18. Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion.
19. Do not sit on the unit or place anything on it.
20. Do not dispose of the remote control in fire, the batteries inside may explode or leak.
21. Before storing, the water must be drained from the unit and the filters cleaned.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by
US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and
a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage
between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the
devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby.
The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be
connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or
attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DIAGRAM
A
FRONT
A. Control panel
B. Interior Louvers
C. Exterior Louvers
D. Casters
B
B
E
F
C
E. Recessed Handle
F. Water Bucket
G. Power Cable and Plug
D
G
BACK
A. Hot air outlet grill
B. Air inlet grill
C. Filter
C
D
D. Drain Valve
A
B
ACCESSORIES
• Flexible exhaust hose and
window exhaust adapter
• 3-Piece adjustable window kit
• Drain tube
• 4 3/8” screws
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
SELECTING THE LOCATION
Place the unit in a flat location where the air outlets are not obstructed. Place the unit at least 20” (50cm) away from a wall or
other obstacle.
MOUNTING THE EXHAUST HOSE
Slide the square end of the exhaust duct over the hot air outlet on the back of the unit.
The exhaust hose should be kept as short and straight as possible. Prevent any sharp bends in the exhaust hose, as this will
trap hot exhaust air.
WALL MOUNTING
The hot exhaust air can be vented through the wall or out a window. If mounting in the wall, the height of the hole should be 16
to 50 inches (40cm to 130cm).
6
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDOW KIT INSTALLATION
The window kit is designed to fit into most
standard vertical and horizontal windows.
However, it may be necessary to modify
some aspects of the installation process
for certain window types.
1. Open the window or sliding door
and adjust the length of the window
kit to fit the opening. Mark and cut
down a single panel of the window
kit if necessary.
2. Place the window kit between the
window and the window frame as
shown in the images to the right.
Close the window onto the window
kit to form a tight seal.
3. Attach the exhaust duct adapter to
the window kit. Tabs located on the
adapter will lock into place securing
the adapter to the window kit.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL PANEL
POWER Button Press this button to turn the unit on or off.
MODE Button
FAN Button
Press this button to select among the modes of cooling, dehumidifying, or fan only.
Press this button to select the desired fan speed.
SWING Button Press this button to oscillate the louvers or stop oscillation.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Plug the power cord into a properly grounded outlet. Do not connect the unit to an outlet that is also being used for
other electrical appliances. The unit will beep after two seconds, then press the on/off button to begin operation.
COOLING
1. Press the Mode Button to choose the cooling function.
2. Press the Fan Speed Button to choose the desired fan speed.
3. Press the Swing Button to select a steady airflow or oscillation.
•
•
In order to improve cooling efficiency, draw the curtains in a room exposed to direct sunlight.
Do not place near a heat source.
DEHUMIDIFYING
1. Press the Mode Button to choose the dehumidifying function.
•
•
•
•
In the Dehumidifying Mode, the fan speed cannot be adjusted.
Ensure that the water bucket is properly placed in the unit.
When the unit is used as a dehumidifier only, do not use the exhaust duct.
Keep the windows and doors closed to aid in effectively dehumidifying the room.
FAN
1. Press the Mode Button to choose the fan function.
2. Press the Fan Speed Button to choose the desired fan speed.
3. Press the Swing Button to select a steady airflow or oscillation.
EMPTYING THE WATER BUCKET
When the unit is in cooling mode, unwanted water is extracted from the air. When the water bucket is full, the compressor will stop
but the fan will continue to run.
To resume operation, empty the water bucket according to the following steps:
1. Turn the unit off. Do not move the unit when the water container is full.
2. Using the handle, slowly remove the water bucket from the unit.
3. Pour out any water accumulated in the bucket.
4. Wash the water bucket using warm water and a mild dishwasher detergent.
5. Allow the bucket to dry completely
6. Replace the water bucket in the unit.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTINUOUS DRAINAGE
1. Slide out the drain valve from the left side of the unit.
2. Connect the drain tube to the valve.
3. Make sure the drain tube drains downward.
4. Place a pan or bucket under the drain tube to hold the condensate water, or let the tube drain down a gravity drain.
Slide out
drain valve
Connect
drain tube to
valve
Make sure
connection is
secure
REMOTE CONTROL
The provided remote control operates all of the functions of the unit. The remote control uses one lithium battery (provided).
Install the battery before using the remote control.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
Always turn off and unplug the unit before
cleaning to avoid electrical shock.
CLEANING THE HOUSING
Wipe the surface of the unit with a soft, damp cloth.
Do not use abrasive chemicals or detergents to
clean the surface of the unit, as the unit may
become scratched or damaged.
Avoid direct exposure to sunlight as this may
change the surface color.
CLEANING THE FILTER
Open the air filter cover on the side of the unit and
remove the filter from the cover.
FILTER
Immerse the filter gently in warm water with a mild
detergent. Rinse thoroughly and dry before
replacing.
An unclean air filter reduces air volume. The filter
should be cleaned every two weeks.
END OF SEASON STORAGE
To store the unit, please follow these steps:
•
•
•
•
•
•
•
•
Turn off and unplug the unit.
Remove the stopper from the water drain pipe and allow it to drain completely.
Drain all condensate water from the water bucket.
Turn the unit to fan mode for a couple of hours to completely dry out the inside.
Clean the filter.
Wrap the cord around the cord hooks.
It is recommended that the unit be packed in its original carton for storage.
Store in a dry location.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Before seeking repair or service, please check the following:
PROBLEM
POSSIBLE CAUSE
REMEDY
Is the unit plugged in?
Securely plug the power cord into the wall outlet.
Reestablish the main power supply.
Is the main power supply on?
Unit does not operate or
only runs in fan mode.
Is the water bucket full indicator light on?
Is the water bucket installed correctly
Empty the water bucket.
Completely insert water bucket
Is the air inlet or outlet blocked?
Is there any other heat source in the room?
Are the air filters dirty?
Clear the blocking.
Move the heat source.
Clean the air filters.
Increase the fan speed.
Cooling efficiency is not
satisfactory.
Is the fan speed set at low?
This unit provides spot cooling or cooling for
rooms up to 150 sq. ft. with a standard 8 ft. ceiling.
Is the room too large for this unit?
Is the machine positioned unevenly on a level
surface?
Unit is noisy or vibrates.
Place the unit on a level surface.
Is the unit positioned on an uneven surface? Place the unit on a level surface
Was the unit moved before emptying the
bucket?
Empty the water bucket before moving the unit
and keep the unit upright at all times.
Water Leaks from the
Unit.
Make sure the stopper on the water drain is
securely in place.
Is the stopper on the water drain pipe loose?
Is the voltage from the power source correct? Use a proper power source.
The unit starts and stops
frequently.
Position the exhaust hose correctly and keep the
exhaust hose straight as possible.
Is the exhaust hose positioned incorrectly?
12
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SPECIFICATIONS
MODEL
MAC-8000
8,000 BTU/Hr
75 Pints per day
850 W
Cooling Capacity
Dehumidifying Capacity
Power Consumption
Cooling:
Dehum:
680 W
Air Flow Volume
Power Source
Rated Current
170 CFM
115 V / 60 HZ
7.4 A
Cooling:
Dehum:
5.9 A
Sound Pressure Level
Weight
<53 db(A)
67 lbs
Dimensions
16.125 X 12.75 X 31.5 inches (WxDxH)
R22
Refrigerant
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL
ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT
CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED
HEREWITHIN.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
One Year Limited Warranty
Soleus International Inc. warrants the accompanying Soleus Air MAC-8000 to be free of defects in material
and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from
the date of original retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it,
free of charge within a reasonable time after the unit is returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along
with a copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
1) Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a
defect in material or workmanship.
2) Damage caused by consumer misuse, tampering, or failure to follow the care and special handling
provisions in the instructions.
3) Damage to the finish of the case, or other appearance parts caused by wear.
4) Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus
International Inc.
5) Freight and Insurance cost for the warranty service.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE
LIMITED TO ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS
INTERNATIONAL INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL
DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE
RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH
RESPECT TO THIS UNIT.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover
used, salvaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not
allow limitation on implied warranties, the above limitations and exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For Warranty, Technical Support, Customer Service, Missing or Defective Parts
Please Call (888) 876-5387
Or Write To:
Soleus International Inc.
9451 Telstar Ave.
El Monte, CA 91731 USA
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|