Sierra Monitor Corporation Air Cleaner IZS30 SERIES User Manual |
DOCUMENT No. : IZ*-OMJ0003
OPERATION MANUAL
PRODUCT NAME
:
Ionizer
MODEL:
IZS30 Series
○Read this operation manual carefully to
understand before installation and operation.
○Pay extra attention on the clause concerning the
safety.
○Keep this operation manual available whenever
necessary.
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Safety instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard by labeling "Caution", "Warning", and
"Danger". To ensure safety, be sure to observe ISO4414, JIS B8370and other safety precautions.
CAUTION Operator error could result in injury or equipment damage.
WARNING Operator error could result in serious injury or loss of life.
DANGER In extreme conditions, there is a possibility of serious injury or loss of life.
WARNING
1.The compatibility of equipment is the responsibility of the person who designs the system
or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility with the
specific system must be based on specifications or after analysis and/or tests to meet your specific
requirements. Those who decide the compatibility of equipment shall take the responsibility to guarantee
the initial system performance and safety. Construct system as reviewing all specifications in the latest
catalog or documents as well as considering the possibility of equipment in every occasion.
2. Only trained personnel should operate machinery and equipment.
This product generates high voltage, so it can be dangerous if an operator is unfamiliar with it. Assembly,
handling or repair of systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to eliminate components until safety is
confirmed.
1) Inspection and maintenance of the machinery and equipment should be performed after
confirmation of the safety such as earthing, prevention of electric shock and each type
of injury.
2) When equipment is to be eliminated, confirm the safety process as mentioned above. Cut
air pressure supply and electric power supply that are the energy source for the
equipment, and exhaust all residual compressed air in the system.
3) Before machinery/equipment is re-started, take measures to prevent short circuit etc. with
enough care.
4.Do not use product under the following conditions or environments. If it is not avoidable,
take appropriate measures and contact SMC.
1) Conditions and environments beyond specifications or if product is used outdoors.
2) Installation on equipment in conjunction with atomic energy, railway, air navigation,
vehicles, medical equipment, food and beverage, recreation equipment , emergency
stop circuits, pressing clutch, break circuit and safety equipment.
3) An application which has the possibility of having negative effects on people, property, or
animals requiring special safety analysis.
Download from Www.Somanuals.com. All Manuals Search And Download.
Selection
WARNING
1. This product is made for general industry. Contact SMC before use, if you are planning to use for
other purposes.
2. Use under specified voltage and temperature.
Voltage out of specification may cause malfunction, breakage, electric shock and fire.
3. Use clean compressed air for fluid.
The construction of this product is not explosion proof. Do not use fluid such as inflammable gas or
explosive gas or use in atmosphere including such a gas. It may result in fire or explosion.
When using fluid other than compressed air, contact SMC.
CAUTION
1. This product has not been washed.
When bringing into clean room. Use after confirming its purification level after flushing.
Installation
WARNING
1. Get required space for maintenance, wiring and piping at installation.
Install connector and One-touch fitting for air supply to be able to eliminate and mount cable and tube.
Do not bend cable and tube with steep angle but fix them straight considering minimum bending
radius to prevent forcible stress applied to installation base of connector and One-touch fitting.
Forcible installation and elimination may cause malfunction, broken wire, fire and air leakage.
Minimum bending radius: Power supply cable
20mm
Sensor cable
20 mm
Note: Here is allowable bending radius when fixing wiring at 20oC. If bending cable at lower
temperature, it may apply forcible force to connector even with minimum bending radius or more.
See instruction or catalog for minimum bending radius fo tube.
2. Install on the plane face.
Forcible force may apply to frame or case due to concave and convex or deformed mounting face and
large level gap, and it may cause breakage or operation failure. Also, dropping or strong impact may
cause operation failure or accident.
3. Do not install with strong electromagnetic source.
Installation with strong electromagnetic source may cause malfunction. Install on the different panel
or separate the mounting.
4. Tighten within the specified torque. tightening torque: See “4. Installation”
When exceeding the tightening torque, mounting screw and mounting bracket etc. might be broken.
The screw might loosen for less than range of the tightening torque.
5. Do not touch electrode needle with finger or metal tool directly. It may cause injury.
If electrode needle or cartridge is damaged by tools, it will not only interfere the specification function
and performance but also may cause operation failure or accident.
6. Be sure to install and adjust after power supply is stopped.
CAUTION
1. Install IZS30 series with keeping distance from the wall etc. as shown in the figure below.
The generated ion might not reach the target effectively and efficiency decrease, where there is wall
etc. inside the area shown in the figure below.
Download from Www.Somanuals.com. All Manuals Search And Download.
150
150
200
200
(mm)
Wiring and piping
WARNING
1. Check that power supply capacity is enough and voltage is in specification before piping.
2. Apply type D earthing to prevent electrical shock in accordance with instructions on this operation
manual.
3. Be sure to cut off power supply at wiring (inclu/ding connector plug-in/out) .
4. Use special cable for the connection between body and sensor, and disassembly and reconstruction
are prohibited.
5. Turn on the power after examining wiring and a surrounding situation enough, and confirming safety.
6. Do not connect and disconnect connectors while supplying the power
7. Installation with high-voltage line and power line in the same wiring route may cause malfunction by
noise. Install separately with them.
8. Be sure there is no incorrect wiring before operation. Incorrect wiring may cause product breakage or
malfunction.
9. Flush pneumatic piping before its installation. Make sure that all dust, water droplet, oil etc. are
eliminated before piping.
Environment
WARNING
1. Use within operating fluid and ambient temperature range.
Operating fluid and ambient temperature range for Ionizer and sensor are 0 to 50oC. When temp. is
5oC or less, take measure to prevent freezing. Though ambient temperature is within specification,
dew condensation might be generated where temperature is suddenly changed. Therefore do not use
under such environment.
2. Environment to avoid
Do not use or store under the following environments, as these may cause operation failure. If it is
unavoidable, take the appropriate measures.
a. The place where ambient temperature exceeds 0 to 5oC.
b. The place where ambient humidity exceeds 35 to 85% RH.
c. The place where dew condensation is generated due to sudden temperature change.
d. The place where there is corrosive gas, inflammable gas, and volatile inflammable substance is
stored.
e. The atmosphere where the product is exposed to conductive powder such as iron powder and dust, oil
mist, salt and organic solvent or machining chips, particles and cutting oil (water, liquid).
f. The place where product is directly exposed to the blow from air-conditioners.
g. The place where sealed and ventilation is not installed.
h. The place the product is exposed to the direct sunlight and radiant heat.
i. The place where strong electromagnetic noise is generated. (Strong electric field/ strong magnetic
field/ surge.)
j. The place where electricity is discharged. The situation which causes electric discharge on the
Download from Www.Somanuals.com. All Manuals Search And Download.
product.
k. The place where strong high frequency is generated.
l. The place where lightning disaster is expected.
m. The place where the product is directly exposed to the vibration and impact.
n. The situation where the force and weight that causes deformation of the product is applied.
3. Do not use air containing mist or dust.
Air containing mist or dust may lower function and shorten maintenance cycle. Mount mist separator
and air dryer in front of filter to produce clean compressed air.
4. Ionizer and sensor are not tolerable against surge of lightning.
Protection against lightning surge should be incorporated in the equipment..
Maintenance
CAUTION
1. Keep electrode needle clean by regular maintenance.
Make sure that the equipment is operating without any failure by regular maintenance. Those who
have enough knowledge and experience should perform the maintenance of the equipment.
Dust attached on the electrode needle due to longer operating lowers the function to eliminate static
electricity. If electrode does not recover its function to eliminate static electricity due to worn out after
cleaning, replace it with the new one. In order to maintain the stable performance, regular
maintenance and cleaning of electrode are recommended.
2. Stop supplying power to the body without fail when cleaning the electrode needle or exchanging the
electrode cartridge. Do not ouch the electrode needle while energizing, or it may cause electric
shock or accident.
3. Do not open the case to disassemble and reconstruct the product.
It may cause electric shock, operation failure and disaster such as fire. In addition, note the product,
which is disassembled or reconstructed, may not satisfy the functions and performance in the
specifications and is out of guarantee.
Handling
WARNING
1. Do not drop, hit to the object and give excessive impact (10G or more) at handling.
Though Ionizer itself doesn’t break, inside construction might be broken and cause malfunction.
2. When cable is mounted or eliminated, pinch modular plug claw with finger and insert or take out the
plug itself vertically. If mounted or eliminated to inappropriate direction, mounting part of modular jack
might be damaged and finally it leads to operation failure.
3. Do not operate with wet hands. It may cause electric shock or accident.
Download from Www.Somanuals.com. All Manuals Search And Download.
2. How to order
Ionizer
I Z S 3 0 – 7 8 0 S B
Bracket
Product name
I Z S 3 0 Bar
B
∗
Mounted
Not mounted
type Ionizer
For "mounted", two brackets for body end
Bar length
300
780
1260
1500
1900
are attached.
300 mm
780 mm
1260 mm
1500 mm
1900 mm
Number of attached bracket for body
middle part is by the bar length.
(See below)
Power supply cable is
attached for all models.
Number of bracket
Bar length
for body middle part
300, 780
1260, 1500
1900
∗
1
2
Sensor
S
∗
Mounted
Not mounted
For [mounted], sensor cable
and sensor bracket are attached.
Sensor
Sensor
I Z S 3 0 - D 1
Part name
D
Type
1
Rotary sector type
Cable
Cable
I Z S 3 0 - C S
I Z S 3 0 - B E
I Z S 3 0 - N T
Part name
C
Type
S
For sensor 3m
For power supply 3m
P
Bracket
Bracket
Type
E
Part name
B
For body end
For body middle part
For sensor
M
S
Electrode needle cartridge
Part name
Type
T
Electrode
Needle cart.
Tungsten
N
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Specifications
3-1. Ionizer
IZS30
-300
IZS30
-780
IZS30
-1260
IZS30
-1500
IZS30
-1900
Ionizer model
Type
Bar type
Corona discharge
Pulse DC
+/-6000V
+/- 30V or less
Air (Clean dry air)
Ion generation principle
Voltage supply method
Discharge output
Ion balance *1
Fluid
Air supply
flow rate *2
(L/min[ANR])
20
50
85
110
135
Purge air
Op. pressure
Max. 0.7
(MPa)
Connection
tube size
φ4
Power supply voltage
SensingDCmode
operated
DC21.6V to 26.4V
150mA or less
Current
SensingDCmode
consumption
100mA or less
100mA or less
NPN Open collector, or no-voltage contact signal
stand-by
Pulse DC mode
Discharge stop
High volt. error
Input signal
Output
signal
Sensor error
Static elimination
completed
FET(Open Drain), DC28V, 100mA or less
50 to 2000mm
(Sensing DC mode 200 to 2000mm)
0 to + 50oC
Effective elimination distance
Ambient temperature
Ambient humidity
Material
35 to 80% Rh (No dew condensation)
Ionizer cover: ABS, Electrode: Tungsten
Endurance 50Hz Amplitude 1mm
2 hours to X,Y,Z each direction of vibration
10G
Vibration resistance
Impact resistance
Weight (g)
330
710
1100
1410
1930
[Note] *1: At distance 300mm between Ionizer and charged object, with purge air.
*2: The smallest flow rate for elimination at distance 200mm between Ionizer and charged object.
3-2. Surface electric potential sensor
Sensor model
IZS30-D1
Detection style
Power supply voltage
Power consumption
Effective detection distance
Ambient temperature
Ambient humidity
Rotary sector style
DC5V (Supplied from Ionizer)
Included in the Sensing DC mode power consumption on the ionizer.
50mm or less
0 to +50oC
35 to 85 % Rh (No dew condensation)
Sensor body: Aluminum
Endurance 50Hz Amplitude 1mm
2 hours to X,Y,Z each direction of vibration
10G
Material
Vibration resistance
Impact resistance
Weight (g)
150
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Installation
4-1. Installation of Ionizer body
Investigate the places where static problem occurs, or process and parts which generate ESD
(Electro static discharge), and carefully consider the required conditions to ensure appropriate
static charge elimination before installation.
Operating distance and static charge elimination time: See [1. installation distance and
static charge elimination time of 6-1.Static charge elimination characteristics
(reference) ].
Static charge elimination area: See [See 2. Static charge elimination area of 6.1 Static
charge elimination characteristics (reference)].
1. Mount end brackets on both sides of the ionizer body with the attached M4 threads.
Recommended tightening torque for M4 thread: 0.75Nm
End bracket
Attached M4 threads
2. Mount intermediate brackets on the ionizer body at regular interval.
Note No intermediate bracket is attached to IZS30-300B (SB), IZS30-780B (SB)).
Intermediate bracket
A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer
body and brackets with M5 threads.
M5 tap
ዩዑbfz
M5 threads
ዩዑp[
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent
threads (M5) of brackets.
Recommended tightening torque for detent thread: 1.5Nm
Fix with detent thread
(Fix the other side too)
Detent
thread
4-2. Installation of surface electric potential sensor
In case of using a surface electric potential sensor, install it on the place which can realize
the precise sensing in order for the detecting hole to sense the target’s static charge.
Note Install so that the detecting hole will be within 50mm from the surface
of target’s static charge..
In case of using a surface electric potential sensor, install it so that the distance
between the object for static charge elimination and the ionizer stays 200 or more.
1) Mount a sensor bracket on the surface electric potential sensor with the attached M5 thread.
Recommended tightening torque for M5 thread: 1.5Nm
Attached M5 screw
ඍ͛ꢀꢁp[ꢂ
2. Insert a sensor bracket into a ꢀ8 rod or hollow piping at the installation side, and fix them with a
thread (M5).
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Peal off the seal attached on the detecting hole of the surface electric potential sensor.
Seal
4. Direct the surface electric potential sensor to the target’s static charge as adjusting the angle, and
fix the detent thread (M5) of bracket.
Recommended tightening torque for detent thread : 1.5 Nm
4-3. Connection of cable
1. Insert the modular plug of power supply cable ZS30-CP into the modular jack for indicating
[power] on the ionizer body. A lever will snap when the modular plug is correctly locked.
Fix cables with a tie wrap or other measures in the vicinity of connection not to apply
compulsive force to the modular jack and plug.
Modular plug
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or
covered with vinyl tape without pealing the coat to prevent them from coming contact with other
wires.
See [4-4. Connection circuit ].
Wiring table for power supply cable IZS30-CP
Pin
Lead wire
color
Brown
Blue
Description
DC21.6 to 26.4V
GND
NC
Stop signal of static charge
elimination
Signal for abnormal
High voltage
Signal for abnormal
sensing
NC
Function
ꢁ
1
2
3
4
Power supply DC + 24 V
Power supply 0V. Be sure to apply class D grounding.
Green
Gray
Connected 0V during operation. Opening stops discharge.
Outputted when abnormal discharge occurs.
5
6
White
Outputted when abnormal operation occurs on the surface
electric potential sensor.
Orange
Red
7
8
Signal for static charge
elimination completion
Notify the progress and completion of static charge elimination
with ON and OFF signal to outside.
Yellow
Note No. 6 and 8 only function when a surface electric potential sensor is used.
2. 3. When a surface electric potential sensor is used, remove the cover cap plugging a
modular jack for indicating [signal] on ionizer body, and insert a modular plug of sensor
cable IZS30-CS. A lever will snap when the modular plug is correctly locked Fix cables with
a tie wrap or other measures in the vicinity of connection not to apply compulsive force to
the modular jack and plug. (Direction of plugs on both sides of cable can be changed.)
Modular plug
Cover cap
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or
covered with vinyl tape without pealing the coat to prevent them from coming contact with other
wires.
See [4-4. Connection circuit ].
Wiring table for power supply cable IZS30-CP
Pin
Lead wire
color
Brown
Blue
Description
DC21.6 to 26.4V
GND
NC
Stop signal of static charge
elimination
Signal for abnormal
High voltage
Signal for abnormal
sensing
NC
Function
ꢁ
1
2
3
4
Power supply DC + 24 V
Power supply 0V. Be sure to apply class D grounding.
Green
Gray
Connected 0V during operation. Opening stops discharge.
Outputted when abnormal discharge occurs.
5
6
White
Outputted when abnormal operation occurs on the surface
electric potential sensor.
Orange
Red
7
8
Signal for static charge
elimination completion
Notify the progress and completion of static charge elimination
with ON and OFF signal to outside.
Yellow
Note No. 6 and 8 only function when a surface electric potential sensor is used.
3. 3. When a surface electric potential sensor is used, remove the cover cap plugging a
modular jack for indicating [signal] on ionizer body, and insert a modular plug of sensor
cable IZS30-CS. A lever will snap when the modular plug is correctly locked Fix cables with
a tie wrap or other measures in the vicinity of connection not to apply compulsive force to
the modular jack and plug. (Direction of plugs on both sides of cable can be changed.)
Modular plug
Cover cap
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Insert the modular plug on the other side of sensor cable IZS30-CS into the modular jack of
the electric potential sensor. If the modular plug is properly inserted and locked, a lever
clicks to notify it’s locked. Fix cables with a tie wrap or other measures in the vicinity of
connection not to apply compulsive force to the modular jack and plug.
Modular plug
Download from Www.Somanuals.com. All Manuals Search And Download.
4-4. Connection circuit
Ionizer POWER connector
Ionizer
INPUT
1.DC+24V Brown
2.GND Blue
Power supply
DC21.6 to 26.4V
GND
24V
6.8k
F.G
PLC
4.Stop signal of
charge elimination(Gray)
OUTPUT
or
INPUT
5.Signal for abnormal
high voltage White
OUTPUT
¥
6.Signal for abnormal
sensing Orange
8.Signal for static
elimination completion
Max. DC28V,100mA
3.7 NC Green and red
[Note 1]
indicates the coating color for lead wire of dedicated cable
Connect [4. Stop signal of static charge elimination] to GND when starting
the ionizer operation.
When the terminal is open, the operation will stop.
[Note 2]
[Note 3]
[6. signal for abnormal sensor] and [8. signal for static charge elimination
completion] functions only when the surface electric potential sensor is
used.
Input and output operation list
Lead wire
ꢁ
Name
Signal
Input
Operation
color
Stop signal of
charge elimination
Connect 4 terminal to GND during operation
Discharge stops when terminal 4 is open.
4
Gray
Signal for abnormal
High voltage
Signal for abnormal
sensing
Tr1 in ionizer is ON when abnormal signal is being
sent.
Tf2 in ionizer is ON is conducted when abnormal
signal is being sent.
5
6
White
Output
Output
Orange
Signal for static
charge elimination
completion
Tr 3 in ionizer is ON when static charge elimination
is completed.
8
Yellow
Output
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Function description
5-1. Operation mode
Three operation modes are available in IZS30. Use these modes depending on applications and
operating conditions.
Op. mode
Operation
Features
Precautions
If surface electric potential sensor
Can shorten static charge cannot tell the target’s static charge
After surface electric elimination time.
potential sensor detects Decide if there is target’s static charge elimination might not be
polarity and electric charge and static charge available.
as indicated below, proper static
potential of the target’s elimination is completed, and - Large work with uneven static
static charge, Ionizer automatically turn ON and OFF electricity.
generates
anti-polarity continuously. and
(Pneumatic valve has to be sensing detection area.
ion
with high pressure power supply - Work moving fast
pneumatic valves. - Work which size is smaller than
prepared separately.)
- Static charge elimination of space or
continuum
1) Since static charge elimination
result differs in the distance to the
target’s static charge and the
operation conditions of air purge, it
should be adjusted with an actual
machine.
Although
potential
surface
sensor
electric
cannot
Discharge
minus ion
frequency of 1Hz to 33Hz
by returns.
plus
in
and
the
properly decide the target’s
static charge such as space or 2) Even after static charge
continuum, stable ion balance
can eliminate the static
electricity.
elimination is completed, surface
potential on the work fluctuates in
the regular frequency just under
the ionizer. In case of selecting low
frequency, amplitude of surface
electric potential may get large.
The parts other than the target’s
static charge should be grounded in
order to prevent charging.
Discharge plus or minus
Ion continuously.
Can be used to charge.
Supplied voltage wave form image diagram
Supplied voltage wave form
Sensing DC
Plus
M inus
Plus
Pulsed DC
M inus
Polarity image of
target’s
charge
static
ᯛᯛᯛ ᯛ ᯛ ᯝᯝ
ᯛ ᯛ ᯝᯝ
Download from Www.Somanuals.com. All Manuals Search And Download.
5-2. Output signal
Signal type
Function
Signal for static charge
elimination completion
(When surface electric
potential sensor is used)
Output when static charge elimination is completed, or no target’s static
charge exists.
Output when any discharge probe gets shorted with other discharge
probes or housing.
Abnormal high voltage
Output when detecting hole of surface electric potential sensor is clogged
with foreign substances, or sector doesn’t rotate properly .
Abnormal sensing
5-3. Function description of indication
1. Power supply indication…Light on Green when power supply is turned ON.
Blink when power supply voltage goes down to defined value.
2. Sensor indication………...Light on Green when surface electric potential sensor is connected
3. Minus indication………….Light on Blue while minus ion is being generated.
4. Indication for static charge elimination completion….Light on Green when static charge
elimination is completed at sensing DC mode.
5. Plus indication…………….Light on Orange while plus ion is being generated.
6. Indication for abnormal high voltage….Light on Red when abnormal current such as high
Voltage leakage is generated.
7. Indication of abnormal sensing…………Light on Red when surface electric potential sensor
cause malfunctions at sensing DC mode.
8. Ion Balance ajastment trimmer………It’s possible to ajust Ion Balance by using the driver
made of the non-metal(Ajusted at shipment).
we’ll recommend the use of the measuring instrument.
Though an accurate ajustment is possible by wear-out
situation of needle,precence of dielectric thing and
potential level of GND in the installation location
9. Frequency selecting switch……………...Select frequency at pulsed DC mode.
No
0---------- 1Hz
1---------- 3Hz
2---------- 5Hz
3---------- 8Hz
4---------- 10Hz
5---------- 15Hz
6---------- 22Hz
7---------- 33Hz
8----------
9----------
Generate only plus ion
Generate only minus ion
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Selection and setting of equipment
6-1. Sensing DC mode
1. selection of bar length
Select the length applicable to work size base on [2. static charge elimination area of 7-1.
static charge elimination characteristics (reference)]
2. Installation of ionizer body
Installation of ionizer body: Install within 200mm to 2000mm from the target’s static charge
See data of [1. Installation distance and static charge elimination time of 7-1. static charge
elimination characteristics (reference)] for static charge elimination time.
3. Installation of surface electric potential sensor
Direct detecting hole to the charged face, and install it within 50mm from the target’s static
charge. (should be installed near the target’s static charge as close as possible.
4. Wiring
Connect ionizer body and surface electric potential sensor with a dedicated cable.
Connecting ionizer body and surface electric potential sensor automatically sets the mode
to sensing DC mode.
Power supply and each input/ output is wired with the dedicated cables. See [wiring table for
power supply cable IZS30-CP of 4-3 cable connection] for wiring table.
5. Pneumatic piping
Since fitting with check valve is used, plug should not be connected on the other side even with
single piping.
Pipe ꢀ4 tube. See [3. specifications] for air flow rate.
When piping is long, required flow rate might not be obtained without both-side piping.
6-2. Pulsed DC mode/ DC mode
1. Selection of bar length
Select the length applicable to work size base on [2. static charge elimination area of 7-1.
static charge elimination characteristics (reference)]
2. Installation of ionizer body
Install within 50mm to 2000mm from the target’s static charge
See data of [1. Installation distance and static charge elimination time of 7-1. static charge
elimination characteristics (reference)] for static charge elimination time.
3. Selection of ion generation frequency
Set selection switch with a screw driver referring to P1 data on operating frequency and static
charge elimination time .
A screw driver slot for selection switch configures like a small arrow. Direct the tip of the arrow
to
the applicable position and set it.
Setting the switch [8] or [9] shift the mode to DC mode, which discharges plus and minus
continuously.
4. Wiring
Connect ionizer body and surface electric potential sensor with a dedicated cable.
Connecting ionizer body and surface electric potential sensor automatically switches the mode
to sensing DC mode.
Power supply and each input/ output is connected with the dedicated cables. See [wiring table
for power supply cable IZS30-CP of 4-3 cable connection] for wiring table.
5. Pneumatic piping
Since fitting with check valve is used, plug should not be connected on the other side even with
single piping.
Pipe ꢀ4 tube. See [3. specifications] for air flow rate.
When piping is long, required flow rate might not be obtained without both-side piping.
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Technical data
7-1. Static charge elimination characteristics (reference
1. Installation distance and static charge elimination time
Installation distance and static charge elimination time (W/O air purge)
ܣ ¾ंᬛචชƸശ፯᭓ Operation frequency (w/o sensor)33Hz
̎ƏʧǬĩᯘ᭦ᮞ᭠ᬝ
፼፷
፻፷
፺፷
W/O sensor
With sensor
፹፷
ꢀTarget’s static charge work
Charged plate dimensions:150×150mm
Capacity:20
ꢀMean.Cond.:Static el.Time for 3kV 0.3kV
፸፷
F
፷
፷ ፼፷፷ ፸፷፷፷ ፸፼፷፷ ፹፷፷፷
Installation distance mm
Installation distance and static charge elimination timeᯘWith air purge
Air purge flow rate: (20 /min ANR) Operating frequency W/O sensor : 33Hz
ꢀTarget’s static charge work
Charged plate Dimension: 150×150mm
Capacity:20pF
ꢀMeas. Cond.: Static el. Time for 3kVꢁ0.3kV
W/O sensor
With sensor
፷ ፼፷፷ ፸፷፷፷ ፸፼፷፷ ፹፷፷፷
Installation distance mm
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Static charge elimination area
Ionizer depth direction
Air purge : N/A
Surface potential Sensor : N/A
Op. Frequency: 33Hz
Ionizer depth direction
-Installed position of target’s static charge mm
ꢀTarget’s work of static charge
Charged plate dimensions: 150×150mm
Capacity:20
ꢀMeas. Cond.: static elimination time 3kVꢁ0.3kV
F
Ionizer width direction
300 to 1900 IZS30 300∗ to IZS30 1900∗
Air purge : N/A
Surface potential Sensor : N/A
Op. Frequency: 33Hz
ꢀTarget’s work of static charge
Charged plate dimensions: 150×150mm
Capacity:20
ꢀMeas. Cond.: static elimination time for 3kVꢁ0.3kV
Ionizer width direction
-installed position of target’s static charge mm
F
Download from Www.Somanuals.com. All Manuals Search And Download.
Ionizer depth direction (with air purge)
Air purge amount : 20l /min ANR
Surface potential Sensor : N/A
Op. Frequency: 33Hz
Ionizer depth direction
-Installed position of target’s static charge mm
ꢀTarget’s work of static charge
Charged plate dimensions: 150×150mm
Capacity:20
ꢀMeas. Cond.: static elimination time for 1kVꢁ0.1kV
F
Ionizer width direction with air purge
300 to 1900 IZS30 300∗ to IZS30 1900∗
Ionizer depth direction
-Installed position of target’s static charge mm
ꢀTarget’s work of static charge
Charged plate dimensions: 150×150mm
Capacity:20
ꢀMeas. Cond.: static elimination time for 1kVꢁ0.1kV
F
Download from Www.Somanuals.com. All Manuals Search And Download.
Charged amount and static charge elimination time
፻
Common conditions
Installed height:250mm
፺
Air purge amount:20 l / min ANR
Op.freq.(in case of W/O sensor) : 33Hz
With Sensor
፹
W/O Sensor
፸
፷
፴፸
፴፹
፴፺
፴፻
W/O Sensor
With Sensor
ꢀTarget’s work of static charge
Charged plate dimensions: 150×150mm
Capacity:20
F
፸ ፹
፷
፺ ፻
Operating frequency and static charge elimination time (W/O surface electric potential sensor)
Installation distance and static charge elimination time
(Air purge:N/A)
ꢀTarget’s work of static charge
Op.freq.1Hz
Charged plate dimensions: 150×150mm
Capacity:20
F
ꢀMeas. Cond.: static elimination time for 3kVꢁ0.3kV
3Hz
10Hz
22Hz
33Hz
Installation distance mm
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation distance and static charge elimination time
(Air purge amount:Refer to Flow rate of air purge in 3.Specification)
Op.freq.33Hz
1Hz
Installation distance mm
7-2. Outline dimensions
1. Ionizer (IZS30-**)
TrimmerforajustingI/B
2-Pipefittingwithcheckvalve
AKH04B-M5-X275
2X4-M4X0.7 Depth 5
(For mounting)
Switchforselectingfrequency
Electrode cartridge
8P Modular jack
(For power supply cable plug)
n (Number of Cartriges)
6P Modular jack
(For sensor cable plug)
Model
n
3
L (mm)
300
IZS30-300**
IZS30-780**
IZS30-1260**
IZS30-1500**
IZS30-1900**
9
15
18
23
780
1260
1500
1900
Download from Www.Somanuals.com. All Manuals Search And Download.
End bracket (IZS30-BE)
Thread for mounting M5
(Should be prepared by user)
Attached thread M4X10L
Angle ajustment available ( 90°)
Intermediate bracket
IZS30-BM
Thread for mounting M5
(Should be prepared by user)
Angle ajustment available ( 90°)
Download from Www.Somanuals.com. All Manuals Search And Download.
Surface electric potential sensor (IZS30-D1)
2X2-M5X0.8 dpt6
2-M5X0.8 dpt7
Detecting hope
6P Modular jack
(For Sensor plug for cable)
Sensor bracket (IZS30-BS)
Shaft ꢂ8 for mounting
(Should be prepared by user)
Mounting hole ꢂ8
Attached thread M5x0.8
IZS30-D1
Download from Www.Somanuals.com. All Manuals Search And Download.
Power supply cable (IZS30-CP)
Sensor cable (IZS30-CS)
Download from Www.Somanuals.com. All Manuals Search And Download.
|