DOCUMENT No. : IZ*-OMJ0003  
OPERATION MANUAL  
PRODUCT NAME  
:
Ionizer  
MODEL:  
IZS30 Series  
Read this operation manual carefully to  
understand before installation and operation.  
Pay extra attention on the clause concerning the  
safety.  
Keep this operation manual available whenever  
necessary.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Safety instructions  
These safety instructions are intended to prevent hazardous situations and/or equipment damage.  
These instructions indicate the level of potential hazard by labeling "Caution", "Warning", and  
"Danger". To ensure safety, be sure to observe ISO4414, JIS B8370and other safety precautions.  
CAUTION Operator error could result in injury or equipment damage.  
WARNING Operator error could result in serious injury or loss of life.  
DANGER In extreme conditions, there is a possibility of serious injury or loss of life.  
WARNING  
1.The compatibility of equipment is the responsibility of the person who designs the system  
or decides its specifications.  
Since the products specified here are used in various operating conditions, their compatibility with the  
specific system must be based on specifications or after analysis and/or tests to meet your specific  
requirements. Those who decide the compatibility of equipment shall take the responsibility to guarantee  
the initial system performance and safety. Construct system as reviewing all specifications in the latest  
catalog or documents as well as considering the possibility of equipment in every occasion.  
2. Only trained personnel should operate machinery and equipment.  
This product generates high voltage, so it can be dangerous if an operator is unfamiliar with it. Assembly,  
handling or repair of systems should be performed by trained and experienced operators.  
3. Do not service machinery/equipment or attempt to eliminate components until safety is  
confirmed.  
1) Inspection and maintenance of the machinery and equipment should be performed after  
confirmation of the safety such as earthing, prevention of electric shock and each type  
of injury.  
2) When equipment is to be eliminated, confirm the safety process as mentioned above. Cut  
air pressure supply and electric power supply that are the energy source for the  
equipment, and exhaust all residual compressed air in the system.  
3) Before machinery/equipment is re-started, take measures to prevent short circuit etc. with  
enough care.  
4.Do not use product under the following conditions or environments. If it is not avoidable,  
take appropriate measures and contact SMC.  
1) Conditions and environments beyond specifications or if product is used outdoors.  
2) Installation on equipment in conjunction with atomic energy, railway, air navigation,  
vehicles, medical equipment, food and beverage, recreation equipment , emergency  
stop circuits, pressing clutch, break circuit and safety equipment.  
3) An application which has the possibility of having negative effects on people, property, or  
animals requiring special safety analysis.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selection  
WARNING  
1. This product is made for general industry. Contact SMC before use, if you are planning to use for  
other purposes.  
2. Use under specified voltage and temperature.  
Voltage out of specification may cause malfunction, breakage, electric shock and fire.  
3. Use clean compressed air for fluid.  
The construction of this product is not explosion proof. Do not use fluid such as inflammable gas or  
explosive gas or use in atmosphere including such a gas. It may result in fire or explosion.  
When using fluid other than compressed air, contact SMC.  
CAUTION  
1. This product has not been washed.  
When bringing into clean room. Use after confirming its purification level after flushing.  
Installation  
WARNING  
1. Get required space for maintenance, wiring and piping at installation.  
Install connector and One-touch fitting for air supply to be able to eliminate and mount cable and tube.  
Do not bend cable and tube with steep angle but fix them straight considering minimum bending  
radius to prevent forcible stress applied to installation base of connector and One-touch fitting.  
Forcible installation and elimination may cause malfunction, broken wire, fire and air leakage.  
Minimum bending radius: Power supply cable  
20mm  
Sensor cable  
20 mm  
Note: Here is allowable bending radius when fixing wiring at 20oC. If bending cable at lower  
temperature, it may apply forcible force to connector even with minimum bending radius or more.  
See instruction or catalog for minimum bending radius fo tube.  
2. Install on the plane face.  
Forcible force may apply to frame or case due to concave and convex or deformed mounting face and  
large level gap, and it may cause breakage or operation failure. Also, dropping or strong impact may  
cause operation failure or accident.  
3. Do not install with strong electromagnetic source.  
Installation with strong electromagnetic source may cause malfunction. Install on the different panel  
or separate the mounting.  
4. Tighten within the specified torque. tightening torque: See “4. Installation”  
When exceeding the tightening torque, mounting screw and mounting bracket etc. might be broken.  
The screw might loosen for less than range of the tightening torque.  
5. Do not touch electrode needle with finger or metal tool directly. It may cause injury.  
If electrode needle or cartridge is damaged by tools, it will not only interfere the specification function  
and performance but also may cause operation failure or accident.  
6. Be sure to install and adjust after power supply is stopped.  
CAUTION  
1. Install IZS30 series with keeping distance from the wall etc. as shown in the figure below.  
The generated ion might not reach the target effectively and efficiency decrease, where there is wall  
etc. inside the area shown in the figure below.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
150  
150  
200  
200  
(mm)  
Wiring and piping  
WARNING  
1. Check that power supply capacity is enough and voltage is in specification before piping.  
2. Apply type D earthing to prevent electrical shock in accordance with instructions on this operation  
manual.  
3. Be sure to cut off power supply at wiring (inclu/ding connector plug-in/out) .  
4. Use special cable for the connection between body and sensor, and disassembly and reconstruction  
are prohibited.  
5. Turn on the power after examining wiring and a surrounding situation enough, and confirming safety.  
6. Do not connect and disconnect connectors while supplying the power  
7. Installation with high-voltage line and power line in the same wiring route may cause malfunction by  
noise. Install separately with them.  
8. Be sure there is no incorrect wiring before operation. Incorrect wiring may cause product breakage or  
malfunction.  
9. Flush pneumatic piping before its installation. Make sure that all dust, water droplet, oil etc. are  
eliminated before piping.  
Environment  
WARNING  
1. Use within operating fluid and ambient temperature range.  
Operating fluid and ambient temperature range for Ionizer and sensor are 0 to 50oC. When temp. is  
5oC or less, take measure to prevent freezing. Though ambient temperature is within specification,  
dew condensation might be generated where temperature is suddenly changed. Therefore do not use  
under such environment.  
2. Environment to avoid  
Do not use or store under the following environments, as these may cause operation failure. If it is  
unavoidable, take the appropriate measures.  
a. The place where ambient temperature exceeds 0 to 5oC.  
b. The place where ambient humidity exceeds 35 to 85% RH.  
c. The place where dew condensation is generated due to sudden temperature change.  
d. The place where there is corrosive gas, inflammable gas, and volatile inflammable substance is  
stored.  
e. The atmosphere where the product is exposed to conductive powder such as iron powder and dust, oil  
mist, salt and organic solvent or machining chips, particles and cutting oil (water, liquid).  
f. The place where product is directly exposed to the blow from air-conditioners.  
g. The place where sealed and ventilation is not installed.  
h. The place the product is exposed to the direct sunlight and radiant heat.  
i. The place where strong electromagnetic noise is generated. (Strong electric field/ strong magnetic  
field/ surge.)  
j. The place where electricity is discharged. The situation which causes electric discharge on the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
product.  
k. The place where strong high frequency is generated.  
l. The place where lightning disaster is expected.  
m. The place where the product is directly exposed to the vibration and impact.  
n. The situation where the force and weight that causes deformation of the product is applied.  
3. Do not use air containing mist or dust.  
Air containing mist or dust may lower function and shorten maintenance cycle. Mount mist separator  
and air dryer in front of filter to produce clean compressed air.  
4. Ionizer and sensor are not tolerable against surge of lightning.  
Protection against lightning surge should be incorporated in the equipment..  
Maintenance  
CAUTION  
1. Keep electrode needle clean by regular maintenance.  
Make sure that the equipment is operating without any failure by regular maintenance. Those who  
have enough knowledge and experience should perform the maintenance of the equipment.  
Dust attached on the electrode needle due to longer operating lowers the function to eliminate static  
electricity. If electrode does not recover its function to eliminate static electricity due to worn out after  
cleaning, replace it with the new one. In order to maintain the stable performance, regular  
maintenance and cleaning of electrode are recommended.  
2. Stop supplying power to the body without fail when cleaning the electrode needle or exchanging the  
electrode cartridge. Do not ouch the electrode needle while energizing, or it may cause electric  
shock or accident.  
3. Do not open the case to disassemble and reconstruct the product.  
It may cause electric shock, operation failure and disaster such as fire. In addition, note the product,  
which is disassembled or reconstructed, may not satisfy the functions and performance in the  
specifications and is out of guarantee.  
Handling  
WARNING  
1. Do not drop, hit to the object and give excessive impact (10G or more) at handling.  
Though Ionizer itself doesn’t break, inside construction might be broken and cause malfunction.  
2. When cable is mounted or eliminated, pinch modular plug claw with finger and insert or take out the  
plug itself vertically. If mounted or eliminated to inappropriate direction, mounting part of modular jack  
might be damaged and finally it leads to operation failure.  
3. Do not operate with wet hands. It may cause electric shock or accident.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. How to order  
Ionizer  
I Z S 3 0 – 7 8 0 S B  
Bracket  
Product name  
I Z S 3 0 Bar  
B
Mounted  
Not mounted  
type Ionizer  
For "mounted", two brackets for body end  
Bar length  
300  
780  
1260  
1500  
1900  
are attached.  
300 mm  
780 mm  
1260 mm  
1500 mm  
1900 mm  
Number of attached bracket for body  
middle part is by the bar length.  
(See below)  
Power supply cable is  
attached for all models.  
Number of bracket  
Bar length  
for body middle part  
300, 780  
1260, 1500  
1900  
1
2
Sensor  
S
Mounted  
Not mounted  
For [mounted], sensor cable  
and sensor bracket are attached.  
Sensor  
Sensor  
I Z S 3 0 - D 1  
Part name  
D
Type  
1
Rotary sector type  
Cable  
Cable  
I Z S 3 0 - C S  
I Z S 3 0 - B E  
I Z S 3 0 - N T  
Part name  
C
Type  
S
For sensor 3m  
For power supply 3m  
P
Bracket  
Bracket  
Type  
E
Part name  
B
For body end  
For body middle part  
For sensor  
M
S
Electrode needle cartridge  
Part name  
Type  
T
Electrode  
Needle cart.  
Tungsten  
N
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Specifications  
3-1. Ionizer  
IZS30  
-300  
IZS30  
-780  
IZS30  
-1260  
IZS30  
-1500  
IZS30  
-1900  
Ionizer model  
Type  
Bar type  
Corona discharge  
Pulse DC  
+/-6000V  
+/- 30V or less  
Air (Clean dry air)  
Ion generation principle  
Voltage supply method  
Discharge output  
Ion balance *1  
Fluid  
Air supply  
flow rate *2  
(L/min[ANR])  
20  
50  
85  
110  
135  
Purge air  
Op. pressure  
Max. 0.7  
(MPa)  
Connection  
tube size  
φ4  
Power supply voltage  
SensingDCmode  
operated  
DC21.6V to 26.4V  
150mA or less  
Current  
SensingDCmode  
consumption  
100mA or less  
100mA or less  
NPN Open collector, or no-voltage contact signal  
stand-by  
Pulse DC mode  
Discharge stop  
High volt. error  
Input signal  
Output  
signal  
Sensor error  
Static elimination  
completed  
FET(Open Drain), DC28V, 100mA or less  
50 to 2000mm  
(Sensing DC mode 200 to 2000mm)  
0 to + 50oC  
Effective elimination distance  
Ambient temperature  
Ambient humidity  
Material  
35 to 80% Rh (No dew condensation)  
Ionizer cover: ABS, Electrode: Tungsten  
Endurance 50Hz Amplitude 1mm  
2 hours to X,Y,Z each direction of vibration  
10G  
Vibration resistance  
Impact resistance  
Weight (g)  
330  
710  
1100  
1410  
1930  
[Note] *1: At distance 300mm between Ionizer and charged object, with purge air.  
*2: The smallest flow rate for elimination at distance 200mm between Ionizer and charged object.  
3-2. Surface electric potential sensor  
Sensor model  
IZS30-D1  
Detection style  
Power supply voltage  
Power consumption  
Effective detection distance  
Ambient temperature  
Ambient humidity  
Rotary sector style  
DC5V (Supplied from Ionizer)  
Included in the Sensing DC mode power consumption on the ionizer.  
50mm or less  
0 to +50oC  
35 to 85 % Rh (No dew condensation)  
Sensor body: Aluminum  
Endurance 50Hz Amplitude 1mm  
2 hours to X,Y,Z each direction of vibration  
10G  
Material  
Vibration resistance  
Impact resistance  
Weight (g)  
150  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Installation  
4-1. Installation of Ionizer body  
Investigate the places where static problem occurs, or process and parts which generate ESD  
(Electro static discharge), and carefully consider the required conditions to ensure appropriate  
static charge elimination before installation.  
Operating distance and static charge elimination time: See [1. installation distance and  
static charge elimination time of 6-1.Static charge elimination characteristics  
(reference) ].  
Static charge elimination area: See [See 2. Static charge elimination area of 6.1 Static  
charge elimination characteristics (reference)].  
1. Mount end brackets on both sides of the ionizer body with the attached M4 threads.  
Recommended tightening torque for M4 thread: 0.75Nm  
End bracket  
Attached M4 threads  
2. Mount intermediate brackets on the ionizer body at regular interval.  
Note No intermediate bracket is attached to IZS30-300B (SB), IZS30-780B (SB)).  
Intermediate bracket  
A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer  
body and brackets with M5 threads.  
M5 tap  
ዩዑbfz  
M5 threads  
ዩዑp[  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent  
threads (M5) of brackets.  
Recommended tightening torque for detent thread: 1.5Nm  
Fix with detent thread  
(Fix the other side too)  
Detent  
thread  
4-2. Installation of surface electric potential sensor  
In case of using a surface electric potential sensor, install it on the place which can realize  
the precise sensing in order for the detecting hole to sense the target’s static charge.  
Note Install so that the detecting hole will be within 50mm from the surface  
of target’s static charge..  
In case of using a surface electric potential sensor, install it so that the distance  
between the object for static charge elimination and the ionizer stays 200 or more.  
1) Mount a sensor bracket on the surface electric potential sensor with the attached M5 thread.  
Recommended tightening torque for M5 thread: 1.5Nm  
Attached M5 screw  
ඍ͛ꢀꢁp[ꢂ  
2. Insert a sensor bracket into a 8 rod or hollow piping at the installation side, and fix them with a  
thread (M5).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Peal off the seal attached on the detecting hole of the surface electric potential sensor.  
Seal  
4. Direct the surface electric potential sensor to the target’s static charge as adjusting the angle, and  
fix the detent thread (M5) of bracket.  
Recommended tightening torque for detent thread : 1.5 Nm  
4-3. Connection of cable  
1. Insert the modular plug of power supply cable ZS30-CP into the modular jack for indicating  
[power] on the ionizer body. A lever will snap when the modular plug is correctly locked.  
Fix cables with a tie wrap or other measures in the vicinity of connection not to apply  
compulsive force to the modular jack and plug.  
Modular plug  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or  
covered with vinyl tape without pealing the coat to prevent them from coming contact with other  
wires.  
See [4-4. Connection circuit ].  
Wiring table for power supply cable IZS30-CP  
Pin  
Lead wire  
color  
Brown  
Blue  
Description  
DC21.6 to 26.4V  
GND  
NC  
Stop signal of static charge  
elimination  
Signal for abnormal  
High voltage  
Signal for abnormal  
sensing  
NC  
Function  
1
2
3
4
Power supply DC + 24 V  
Power supply 0V. Be sure to apply class D grounding.  
Green  
Gray  
Connected 0V during operation. Opening stops discharge.  
Outputted when abnormal discharge occurs.  
5
6
White  
Outputted when abnormal operation occurs on the surface  
electric potential sensor.  
Orange  
Red  
7
8
Signal for static charge  
elimination completion  
Notify the progress and completion of static charge elimination  
with ON and OFF signal to outside.  
Yellow  
Note No. 6 and 8 only function when a surface electric potential sensor is used.  
2. 3. When a surface electric potential sensor is used, remove the cover cap plugging a  
modular jack for indicating [signal] on ionizer body, and insert a modular plug of sensor  
cable IZS30-CS. A lever will snap when the modular plug is correctly locked Fix cables with  
a tie wrap or other measures in the vicinity of connection not to apply compulsive force to  
the modular jack and plug. (Direction of plugs on both sides of cable can be changed.)  
Modular plug  
Cover cap  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or  
covered with vinyl tape without pealing the coat to prevent them from coming contact with other  
wires.  
See [4-4. Connection circuit ].  
Wiring table for power supply cable IZS30-CP  
Pin  
Lead wire  
color  
Brown  
Blue  
Description  
DC21.6 to 26.4V  
GND  
NC  
Stop signal of static charge  
elimination  
Signal for abnormal  
High voltage  
Signal for abnormal  
sensing  
NC  
Function  
1
2
3
4
Power supply DC + 24 V  
Power supply 0V. Be sure to apply class D grounding.  
Green  
Gray  
Connected 0V during operation. Opening stops discharge.  
Outputted when abnormal discharge occurs.  
5
6
White  
Outputted when abnormal operation occurs on the surface  
electric potential sensor.  
Orange  
Red  
7
8
Signal for static charge  
elimination completion  
Notify the progress and completion of static charge elimination  
with ON and OFF signal to outside.  
Yellow  
Note No. 6 and 8 only function when a surface electric potential sensor is used.  
3. 3. When a surface electric potential sensor is used, remove the cover cap plugging a  
modular jack for indicating [signal] on ionizer body, and insert a modular plug of sensor  
cable IZS30-CS. A lever will snap when the modular plug is correctly locked Fix cables with  
a tie wrap or other measures in the vicinity of connection not to apply compulsive force to  
the modular jack and plug. (Direction of plugs on both sides of cable can be changed.)  
Modular plug  
Cover cap  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Insert the modular plug on the other side of sensor cable IZS30-CS into the modular jack of  
the electric potential sensor. If the modular plug is properly inserted and locked, a lever  
clicks to notify it’s locked. Fix cables with a tie wrap or other measures in the vicinity of  
connection not to apply compulsive force to the modular jack and plug.  
Ღᱳ  
Modular plug  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-4. Connection circuit  
Ionizer POWER connector  
Ionizer  
INPUT  
1.DC+24V Brown  
2.GND Blue  
Power supply  
DC21.6 to 26.4V  
GND  
24V  
6.8k  
F.G  
PLC  
4.Stop signal of  
charge elimination(Gray)  
OUTPUT  
or  
INPUT  
5.Signal for abnormal  
high voltage White  
OUTPUT  
¥
6.Signal for abnormal  
sensing Orange  
8.Signal for static  
elimination completion  
Max. DC28V,100mA  
3.7 NC Green and red  
[Note 1]  
indicates the coating color for lead wire of dedicated cable  
Connect [4. Stop signal of static charge elimination] to GND when starting  
the ionizer operation.  
When the terminal is open, the operation will stop.  
[Note 2]  
[Note 3]  
[6. signal for abnormal sensor] and [8. signal for static charge elimination  
completion] functions only when the surface electric potential sensor is  
used.  
Input and output operation list  
Lead wire  
Name  
Signal  
Input  
Operation  
color  
Stop signal of  
charge elimination  
Connect 4 terminal to GND during operation  
Discharge stops when terminal 4 is open.  
4
Gray  
Signal for abnormal  
High voltage  
Signal for abnormal  
sensing  
Tr1 in ionizer is ON when abnormal signal is being  
sent.  
Tf2 in ionizer is ON is conducted when abnormal  
signal is being sent.  
5
6
White  
Output  
Output  
Orange  
Signal for static  
charge elimination  
completion  
Tr 3 in ionizer is ON when static charge elimination  
is completed.  
8
Yellow  
Output  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Function description  
5-1. Operation mode  
Three operation modes are available in IZS30. Use these modes depending on applications and  
operating conditions.  
Op. mode  
Operation  
Features  
Precautions  
If surface electric potential sensor  
Can shorten static charge cannot tell the target’s static charge  
After surface electric elimination time.  
potential sensor detects Decide if there is target’s static charge elimination might not be  
polarity and electric charge and static charge available.  
as indicated below, proper static  
potential of the target’s elimination is completed, and - Large work with uneven static  
static charge, Ionizer automatically turn ON and OFF electricity.  
generates  
anti-polarity continuously. and  
(Pneumatic valve has to be sensing detection area.  
ion  
with high pressure power supply - Work moving fast  
pneumatic valves. - Work which size is smaller than  
prepared separately.)  
- Static charge elimination of space or  
continuum  
1) Since static charge elimination  
result differs in the distance to the  
target’s static charge and the  
operation conditions of air purge, it  
should be adjusted with an actual  
machine.  
Although  
potential  
surface  
sensor  
electric  
cannot  
Discharge  
minus ion  
frequency of 1Hz to 33Hz  
by returns.  
plus  
in  
and  
the  
properly decide the target’s  
static charge such as space or 2) Even after static charge  
continuum, stable ion balance  
can eliminate the static  
electricity.  
elimination is completed, surface  
potential on the work fluctuates in  
the regular frequency just under  
the ionizer. In case of selecting low  
frequency, amplitude of surface  
electric potential may get large.  
The parts other than the target’s  
static charge should be grounded in  
order to prevent charging.  
Discharge plus or minus  
Ion continuously.  
Can be used to charge.  
Supplied voltage wave form image diagram  
Supplied voltage wave form  
Sensing DC  
Plus  
M inus  
Plus  
Pulsed DC  
M inus  
Polarity image of  
target’s  
charge  
static  
ᯛᯛᯛ ᯛ ᯛ ᯝᯝ  
ᯛ ᯛ ᯝ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-2. Output signal  
Signal type  
Function  
Signal for static charge  
elimination completion  
(When surface electric  
potential sensor is used)  
Output when static charge elimination is completed, or no target’s static  
charge exists.  
Output when any discharge probe gets shorted with other discharge  
probes or housing.  
Abnormal high voltage  
Output when detecting hole of surface electric potential sensor is clogged  
with foreign substances, or sector doesn’t rotate properly .  
Abnormal sensing  
5-3. Function description of indication  
1. Power supply indication…Light on Green when power supply is turned ON.  
Blink when power supply voltage goes down to defined value.  
2. Sensor indication………...Light on Green when surface electric potential sensor is connected  
3. Minus indication………….Light on Blue while minus ion is being generated.  
4. Indication for static charge elimination completion….Light on Green when static charge  
elimination is completed at sensing DC mode.  
5. Plus indication…………….Light on Orange while plus ion is being generated.  
6. Indication for abnormal high voltage….Light on Red when abnormal current such as high  
Voltage leakage is generated.  
7. Indication of abnormal sensing…………Light on Red when surface electric potential sensor  
cause malfunctions at sensing DC mode.  
8. Ion Balance ajastment trimmer………It’s possible to ajust Ion Balance by using the driver  
made of the non-metal(Ajusted at shipment).  
we’ll recommend the use of the measuring instrument.  
Though an accurate ajustment is possible by wear-out  
situation of needle,precence of dielectric thing and  
potential level of GND in the installation location  
9. Frequency selecting switch……………...Select frequency at pulsed DC mode.  
No  
0---------- 1Hz  
1---------- 3Hz  
2---------- 5Hz  
3---------- 8Hz  
4---------- 10Hz  
5---------- 15Hz  
6---------- 22Hz  
7---------- 33Hz  
8----------  
9----------  
Generate only plus ion  
Generate only minus ion  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Selection and setting of equipment  
6-1. Sensing DC mode  
1. selection of bar length  
Select the length applicable to work size base on [2. static charge elimination area of 7-1.  
static charge elimination characteristics (reference)]  
2. Installation of ionizer body  
Installation of ionizer body: Install within 200mm to 2000mm from the target’s static charge  
See data of [1. Installation distance and static charge elimination time of 7-1. static charge  
elimination characteristics (reference)] for static charge elimination time.  
3. Installation of surface electric potential sensor  
Direct detecting hole to the charged face, and install it within 50mm from the target’s static  
charge. (should be installed near the target’s static charge as close as possible.  
4. Wiring  
Connect ionizer body and surface electric potential sensor with a dedicated cable.  
Connecting ionizer body and surface electric potential sensor automatically sets the mode  
to sensing DC mode.  
Power supply and each input/ output is wired with the dedicated cables. See [wiring table for  
power supply cable IZS30-CP of 4-3 cable connection] for wiring table.  
5. Pneumatic piping  
Since fitting with check valve is used, plug should not be connected on the other side even with  
single piping.  
Pipe 4 tube. See [3. specifications] for air flow rate.  
When piping is long, required flow rate might not be obtained without both-side piping.  
6-2. Pulsed DC mode/ DC mode  
1. Selection of bar length  
Select the length applicable to work size base on [2. static charge elimination area of 7-1.  
static charge elimination characteristics (reference)]  
2. Installation of ionizer body  
Install within 50mm to 2000mm from the target’s static charge  
See data of [1. Installation distance and static charge elimination time of 7-1. static charge  
elimination characteristics (reference)] for static charge elimination time.  
3. Selection of ion generation frequency  
Set selection switch with a screw driver referring to P1 data on operating frequency and static  
charge elimination time .  
A screw driver slot for selection switch configures like a small arrow. Direct the tip of the arrow  
to  
the applicable position and set it.  
Setting the switch [8] or [9] shift the mode to DC mode, which discharges plus and minus  
continuously.  
4. Wiring  
Connect ionizer body and surface electric potential sensor with a dedicated cable.  
Connecting ionizer body and surface electric potential sensor automatically switches the mode  
to sensing DC mode.  
Power supply and each input/ output is connected with the dedicated cables. See [wiring table  
for power supply cable IZS30-CP of 4-3 cable connection] for wiring table.  
5. Pneumatic piping  
Since fitting with check valve is used, plug should not be connected on the other side even with  
single piping.  
Pipe 4 tube. See [3. specifications] for air flow rate.  
When piping is long, required flow rate might not be obtained without both-side piping.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Technical data  
7-1. Static charge elimination characteristics (reference  
1. Installation distance and static charge elimination time  
Installation distance and static charge elimination time (W/O air purge)  
ܣ
¾ं෼ᬛචชƸശ፯᭓  
Operation frequency (w/o sensor)33Hz  
̎ƏʧǬĩᯘ᭦ᮞ᭠ᬝ  
፼፷  
፻፷  
፺፷  
W/O sensor  
With sensor  
᭦ ᮞ  
፹፷  
Target’s static charge work  
Charged plate dimensions:150×150mm  
Capacity:20  
Mean.Cond.:Static el.Time for 3kV 0.3kV  
፸፷  
F
፷ ፼፷፷ ፸፷፷፷ ፸፼፷፷ ፹፷፷፷  
Installation distance mm  
ܣ
¾ं෼  
Installation distance and static charge elimination timeWith air purge
ᯙ  
Air purge flow rate: (20 /min ANR) Operating frequency W/O sensor : 33Hz  
፹፼  
፹፷  
፸፼  
፸፷  
Target’s static charge work  
Charged plate Dimension: 150×150mm  
Capacity:20pF  
Meas. Cond.: Static el. Time for 3kV0.3kV  
W/O sensor  
With sensor  
፷ ፼፷፷ ፸፷፷፷ ፸፼፷፷ ፹፷፷፷  
Installation distance mm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Static charge elimination area  
Ionizer depth direction  
Air purge : N/A  
Surface potential Sensor : N/A  
Op. Frequency: 33Hz  
Ionizer depth direction  
-Installed position of target’s static charge mm  
Target’s work of static charge  
Charged plate dimensions: 150×150mm  
Capacity:20  
Meas. Cond.: static elimination time 3kV0.3kV  
F
Ionizer width direction  
300 to 1900 IZS30 300to IZS30 1900∗  
Air purge : N/A  
Surface potential Sensor : N/A  
Op. Frequency: 33Hz  
Target’s work of static charge  
Charged plate dimensions: 150×150mm  
Capacity:20  
Meas. Cond.: static elimination time for 3kV0.3kV  
Ionizer width direction  
-installed position of target’s static charge mm  
F
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ionizer depth direction (with air purge)  
Air purge amount : 20l /min ANR  
Surface potential Sensor : N/A  
Op. Frequency: 33Hz  
Ionizer depth direction  
-Installed position of target’s static charge mm  
Target’s work of static charge  
Charged plate dimensions: 150×150mm  
Capacity:20  
Meas. Cond.: static elimination time for 1kV0.1kV  
F
Ionizer width direction with air purge  
300 to 1900 IZS30 300to IZS30 1900∗  
Ionizer depth direction  
-Installed position of target’s static charge mm  
Target’s work of static charge  
Charged plate dimensions: 150×150mm  
Capacity:20  
Meas. Cond.: static elimination time for 1kV0.1kV  
F
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charged amount and static charge elimination time  
Common conditions  
Installed height:250mm  
Air purge amount:20 l / min ANR  
Op.freq.(in case of W/O sensor) : 33Hz  
With Sensor  
W/O Sensor  
b
፴፸  
፴፹  
፴፺  
፴፻  
Ꮂ᎝  
W/O Sensor  
With Sensor  
Target’s work of static charge  
Charged plate dimensions: 150×150mm  
Capacity:20  
F
፸ ፹  
፺ ፻  
᎛ᎰᎴᎬ ᎺᎬᎪ  
Operating frequency and static charge elimination time (W/O surface electric potential sensor)  
Installation distance and static charge elimination time  
(Air purge:N/A)  
፻፷  
Target’s work of static charge  
Op.freq.1Hz  
Charged plate dimensions: 150×150mm  
፺፼  
Capacity:20  
F
Meas. Cond.: static elimination time for 3kV0.3kV  
፺፷  
፹፼  
፹፷  
፸፼  
፸፷  
3Hz  
10Hz  
22Hz  
33Hz  
፷ ፹፷፷ ፻፷፷ ፽፷፷ ፿፷፷ ፸፷፷፷  
Installation distance mm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation distance and static charge elimination time  
(Air purge amount:Refer to Flow rate of air purge in 3.Specification)  
፹፼  
፹፷  
፸፼  
፸፷  
Op.freq.33Hz  
1Hz  
፷ ፼፷፷
 
፸፷፷፷ ፸፼፷፷ ፹፷፷፷  
Installation distance mm  
7-2. Outline dimensions  
1. Ionizer (IZS30-**)  
TrimmerforajustingI/B  
2-Pipefittingwithcheckvalve  
AKH04B-M5-X275  
2X4-M4X0.7 Depth 5  
(For mounting)  
Switchforselectingfrequency  
Electrode cartridge  
8P Modular jack  
(For power supply cable plug)  
n (Number of Cartriges)  
6P Modular jack  
(For sensor cable plug)  
Model  
n
3
L (mm)  
300  
IZS30-300**  
IZS30-780**  
IZS30-1260**  
IZS30-1500**  
IZS30-1900**  
9
15  
18  
23  
780  
1260  
1500  
1900  
Download from Www.Somanuals.com. All Manuals Search And Download.  
End bracket (IZS30-BE)  
Thread for mounting M5  
(Should be prepared by user)  
Attached thread M4X10L  
Angle ajustment available ( 90°)  
Intermediate bracket  
IZS30-BM  
Thread for mounting M5  
(Should be prepared by user)  
Angle ajustment available ( 90°)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Surface electric potential sensor (IZS30-D1)  
2X2-M5X0.8 dpt6  
2-M5X0.8 dpt7  
Detecting hope  
6P Modular jack  
(For Sensor plug for cable)  
Sensor bracket (IZS30-BS)  
Shaft 8 for mounting  
(Should be prepared by user)  
Mounting hole 8  
Attached thread M5x0.8  
IZS30-D1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power supply cable (IZS30-CP)  
Sensor cable (IZS30-CS)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp All in One Printer AR 5516S User Manual
Shoprider Mobility Aid 858WM User Manual
Sony All in One Printer UP DR80MD User Manual
Sony Car Stereo System CDX M620 User Manual
Sony CD Player CDX 646X User Manual
Sony Ericsson Cell Phone Z750a User Manual
Sony Speaker XS 5726 User Manual
Sony Universal Remote RM LG112 User Manual
Sun Microsystems Server 2005Q1 User Manual
Talk electronic CD Player Thunder 22 User Manual