PN-E601
PN-E521
LCD MONITOR
OPERATION GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
Part Names
Front view
n
1. LCD panel
2. Remote control sensor
3. Input switch (See page 5.)
4. Power switch
5. Power LED
1
TIPS
• Use a pointed object such as a pen tip to press the
switches at the front of the monitor.
2
3
4
5
Rear view
n
12
1. AC input terminal
2. Main power switch
3. PC/AV HDMI input terminal
4. PC D-sub input terminal
5. Audio input terminal
14
13
6. Audio output terminals
7. RS-232C output terminal
8. RS-232C input terminal
9. Optional terminal
This terminal is provided for possible future (optional)
function expansion. Offering of this terminal is not a
guarantee that future expanded functionality will be
provided.
10
11
5 6 7
10. Expansion terminal cover
Additional input/output terminals are available by attaching
the PN-ZB01 interface expansion board (optional).
11. Optional attachment section
This section is used to connect optional hardware for
function expansion. Offering this attachment location
is not a guarantee that future compatible hardware
attachments will be released.
1
3
4
9
2
8
When the PN-ZB01 (optional)
is attached
12. Speakers
13. Handles
14. Vents
15 16 17 18 19 20 21 2324
When the PN-ZB01 (optional) is attached
15. PC/AV DVI-D input terminal
16. PC/AV DVI-D output terminal
17. LAN terminal
18. External speaker terminals
19. Audio 1 input terminals
20. Audio 2 input terminals
21. PC RGB input terminals
22. AV component input terminals
23. AV video input terminal
24. AV S-video input terminal
Caution
• Consult your SHARP dealer for attachment/detachment of
optional parts.
• Do not open the expansion terminal cover by yourself.
There are high voltage parts inside the cover which may
cause an electric shock.
E
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Part Names
Remote control unit
n
1. Signal transmitter
1
2. POWER button
3. MUTE button (See page 5.)
4. VOL +/- buttons (See page 5.)
BRIGHT +/- buttons (See page 5.)
Cursor control (
/
/
/
) buttons
7
8
2
3
5. DISPLAY button (See page 5.)
6. MODE button (See page 5.)
7. INPUT button (See page 5.)
8. MENU button (See page 5.)
9. SIZE button (See page 5.)
4
9
5
6
E
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Basic Operation
3. MENU
Displays and turns off the menu screen (see page 7).
1
4. VOL +/- (Volume adjustment)
Pressing
or displays the VOLUME menu when the
menu screen is not displayed.
2
5
3
4
V O L U M E
15
Press
or
to adjust the volume of the sound.
* If you do not press any buttons for about 4 seconds, the
VOLUME menu automatically disappears.
5. BRIGHT +/- (Backlight adjustment)
Pressing
menu screen is not displayed.
or
displays the BRIGHT menu when the
6
7
8
B R I G H T
15
Press
or
to adjust the brightness.
* If you do not press any buttons for about 4 seconds, the
BRIGHT menu automatically disappears.
1. INPUT (Input mode selection)
The menu is displayed. Press
or
to select the input
6. SIZE (Screen size selection)
The menu is displayed.
mode, and press
to enter.
* You can select the input terminal by pressing the input
switch of the monitor.
Press
or
to select the screen size. (See page 6.)
7. DISPLAY
Input mode
PC D-SUB
Video
Audio
Displays monitor information. When you press this button
again, the display disappears.
PC D-sub input terminal
PC/AV HDMI input terminal*1
PC/AV HDMI input terminal*1
Audio input terminal
PC HDMI
AV HDMI
*2
When the PN-ZB01 (optional) is attached, the display changes
from INFORMATION1 → INFORMATION2 → clear display,
and so on every time you press this button.
• The display disappears automatically after about 15
seconds.
When the PN-ZB01 (optional) is attached
Input mode
PC DVI-D
Video
Audio
PC/AV DVI-D input terminal*3
PC/AV HDMI input terminal*1
PC D-sub input terminal
PC RGB input terminals*4
PC/AV DVI-D input terminal*3
PC/AV HDMI input terminal*1
•
LAN is displayed during LAN communication.
PC HDMI
PC D-SUB
PC RGB
• If LAN is displayed in red, there is a duplicate IP address.
8. MODE (Color mode selection)
Each time you press this button, the color mode changes in
the following order:
*2
AV DVI-D
AV HDMI
AV COMPONENT AV COMPONENT input terminals*4
STD (Standard) → VIVID → sRGB → STD...
AV S-VIDEO
AV VIDEO
AV S-video input terminal
AV video input terminal
• sRGB applies to PC input only.
sRGB is international standard of color representation
specified by IEC (International Electrotechnical
Commission). Color conversion is made in taking account
of liquid crystal’s characteristics and represents color tone
close to its original image.
*1 Select the terminal to be used in HDMI of INPUT SELECT.
(See page 12.)
*2 Select the terminal for AUDIO SELECT which is used for
audio input. (See page 12.)
*3 Select the terminal to be used in DVI of INPUT SELECT.
(See page 12.)
*4 Select the terminal to be used in BNC of INPUT SELECT.
(See page 12.)
2. MUTE
Turns off the volume temporarily.
Press the MUTE button again to turn the sound back to the
previous level.
E
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Basic Operation
Switching the screen size
n
Even when the screen size is changed, the display may remain the same depending on the input signal.
WIDE
PC input
AV input
PC input
AV input
PC input
AV input
PC input
AV input
PC input
AV input
Displays image so it fills the entire screen.
An image with a 4:3 aspect ratio is stretched to fill the entire
screen.
ZOOM 1
ZOOM 2
NORMAL
Dot by Dot
An image with a 4:3 aspect ratio is enlarged to fill the entire screen
without changing the aspect ratio. The edges of the image may be
cut off.
Use this size if ZOOM 1 cuts off the subtitles.
Displays image so it fills the screen without changing the aspect
ratio of the input signals.
Displays the entire image of the aspect ratio of 4:3 without
changing the aspect ratio.
Displays the dots of the signals input from the connected PC as
the corresponding dots on the screen. *
Displays the dots of the input signals as the corresponding dots on
the screen.
*: With a monitor of screen resolution 1600 x 1200 or 1920 x 1200, selecting Dot by Dot displays the NORMAL screen.
TIPS
• Using this monitor’s screen-size switching or dual-screen display functions to compress or expand the screen for commercial
or public viewing in establishments like cafes or hotels may infringe on the rights of the creators, as protected by Copyright
Law, so please be careful.
• When “Enlarge” is set, the screen size is fixed to “WIDE” mode.
• When dual-screen display is selected, the screen size cannot be changed.
• The appearance of the original video may change if you select a screen size with a different aspect ratio than the original
image (e.g. TV broadcast or video input from external equipment).
• When an ordinary non-wide image (4:3) is viewed with the whole screen using the screen-size switching function of this
monitor, the edge of the image may be lost or appear distorted. If you wish to respect the creator’s intentions, set the screen
size to “NORMAL”.
• When playing commercial software, parts of the image (like subtitles) may be cropped. In this case select the optimal screen
size using the screen-size switching function of this monitor. With some software, there may be noise or distortion at the
edges of the screen. This is due to the characteristics of the software, and is not a malfunction.
• Depending on the original image size, black bands may remain at the edges of the screen.
E
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
TIPS
Displaying the menu screen
• The menu will differ depending on the input mode.
• The menu screen will close automatically if no operation is
performed for about 15 seconds. (DATE/TIME SETTING,
SCHEDULE and LAN SETUP screens will close in about 4
minutes.)
Video and audio adjustment and settings of various functions
are enabled. This section describes how to use the menu
items. See pages 10 to 13 for details of each menu items.
Caution
Menu screen display
n
• Do not turn the main power switch off while the menu items
are being displayed. Doing so may initialize the settings.
1
3
2
4
SCREEN
PICTURE
AUDIO
PICTURE
1/2
PC D-SUB
Example of operation
n
AUTO
(Adjusting CONTRAST in the PICTURE menu)
1. Press MENU to display the menu screen.
CONTRAST
BLACK LEVEL
TINT
78
84
30
30
12
SETUP
SCREEN
PICTURE
AUDIO
SCREEN
1/1
PC D-SUB
OPTION
ENLARGE
PIP/PbyP
AUTO
COLORS
600
25
CLOCK
PHASE
SHARPNESS
610
37
H-POS
SETUP
V-POS
OK···[MENU]
H-SIZE
50
1 9 2 0 x 1 0 8 0
V: 60 Hz H: 67.5 kHz
OPTION
ENLARGE
PIP/PbyP
V-SIZE
50
H-RESOLUTION
V-RESOLUTION
RESET
1920
1080
1 Name of the menu
2 Input mode
3 An item being selected (highlighted)
END···[MENU]
1 9 2 0 x 1 0 8 0
V: 60 Hz H: 67.5 kHz
4 Screen resolution of input signal, and other data.
2. Press
or
to select PICTURE, and press
.
PICTURE menu is displayed.
TIPS
• Items that cannot be selected appear in gray.
(e.g. Function not supported by the current input signal)
3. Press
or
to select CONTRAST.
SCREEN
PICTURE
AUDIO
PICTURE
1/2
PC D-SUB
AUTO
CONTRAST
BLACK LEVEL
TINT
78
84
30
30
12
SETUP
OPTION
ENLARGE
PIP/PbyP
COLORS
SHARPNESS
OK···[MENU]
1 9 2 0 x 1 0 8 0
V: 60 Hz H: 67.5 kHz
4. Press
or
to adjust the setting.
SCREEN
PICTURE
AUDIO
PICTURE
1/2
PC D-SUB
AUTO
CONTRAST
88
84
30
30
12
SETUP
BLACK LEVEL
TINT
OPTION
ENLARGE
PIP/PbyP
COLORS
SHARPNESS
OK···[MENU]
1 9 2 0 x 1 0 8 0
V: 60 Hz H: 67.5 kHz
For items that have
press MENU
, press
, make settings and then
.
5. Press MENU twice to close the menu screen.
E
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
List of menu items
The displayed menu items vary depending on whether or not the PN-ZB01 (optional) is attached.
○: Item is available, -: Item is not available.
PN-ZB01 (optional)
Not attached Attached
Menu
SCREEN
Item
AUTO
○
○
CLOCK
PHASE
H-POS
V-POS
H-SIZE
V-SIZE
H-RESOLUTION
V-RESOLUTION
RESET
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
-
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
-
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
PICTURE
AUTO
CONTRAST
BLACK LEVEL
TINT
COLORS
SHARPNESS
ADVANCED
FLESH TONE
3D-NR
MPEG-NR
3D-Y/C
C.M.S.-HUE
C.M.S.-SATURATION
C.M.S.-VALUE
COLOR MODE
WHITE BALANCE
PRESET
R-CONTRAST
G-CONTRAST
B-CONTRAST
COPY TO USER
GAMMA
RESET
TREBLE
BASS
BALANCE
AUDIO
SETUP
RESET
OSD H-POSITION
OSD V-POSITION
MONITOR
MONAURAL AUDIO
LANGUAGE
POWER ON DELAY
STANDBY MODE
HDMI SETTING
HDMI AUTO VIEW
HDMI RGB INPUT RANGE
HOT PLUG CONTROL HDMI
DVI
RS-232C/LAN SELECT
ID No. SET
BAUD RATE
LAN SETUP
-
○
○
-
-
○
SPEAKER SELECT
OPTION DC OUT SETTING
E
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
PN-ZB01 (optional)
Menu
OPTION
Item
Not attached
Attached
DATE/TIME SETTING
SCHEDULE
INPUT SELECT
○
○
-
-
○
-
○
-
-
-
○
-
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
DVI
BNC
HDMI
AUDIO SELECT
PC DVI-D
PC HDMI
PC D-SUB
PC RGB
AV DVI-D
AV HDMI
AV COMPONENT
AV S-VIDEO
AV VIDEO
480 LINES
768 LINES
1050 LINES
ZOOM2 SPECIAL SETTING
-
-
INPUT SIGNAL
○
○
○
○
○
○
-
SCAN MODE
POWER MANAGEMENT
COLOR SYSTEM
AUDIO OUTPUT
AUDIO INPUT LEVEL
SELF ADJUST
AUTO INPUT CHANGE
ENLARGE H
ENLARGE V
ENLARGE-POS H
ENLARGE-POS V
BEZEL H
BEZEL V
H-POS
V-POS
PIP MODES
PIP SIZE
PIP H-POS
PIP V-POS
PIP BLEND
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
-
ENLARGE
PIP/PbyP
PIP SOURCE
SOUND CHANGE
MAIN POS
PbyP2 POS
AUTO OFF
○
○
○
○
TIPS
• Some items may not be displayed depending on the input mode.
E
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
PICTURE
AUTO (PC D-SUB/PC RGB)
n
Menu item details
The menu will differ depending on the input mode.
The CONTRAST and BLACK LEVEL are automatically
adjusted.
SCREEN
AUTO (PC D-SUB/PC RGB)
n
Pressing
performs adjustment.
CONTRAST
The CLOCK, PHASE, H-POS, and V-POS are automatically
adjusted.
Adjusts the brightness of the image.
BLACK LEVEL
Pressing
performs adjustment.
Use this automatic adjustment when you use the PC D-sub
input terminal or PC RGB input terminals to display a PC
screen for the first time or when you change the setting of
the PC. (See page 16.)
Adjusts the entire brightness of the video signals.
TINT
Adjusts the hue. Selecting + changes the color towards
green, and selecting - changes it towards magenta.
CLOCK (PC D-SUB/PC RGB)
COLORS
Adjusts frequency for sampling clock for applicable video.
Adjust when there is flickering in the form of vertical stripes.
When using the adjustment pattern (see page 16), make
adjustments so that no vertical stripe noise appears in it.
Adjusts the color intensity.
SHARPNESS
Adjusts the sharpness of the image.
ADVANCED (AV input)
You can adjust more specifically. (See page 16.)
COLOR MODE
PHASE (PC D-SUB/PC RGB)
Adjusts sampling clock phase for applicable video.
Useful when small characters appear with low contrast and/
or there are flickers at corners.
When using the adjustment pattern (see page 16), make
adjustments so that no horizontal stripe noise appears in it.
* Adjustments to PHASE should be made only after CLOCK
has been correctly set.
Changes the color mode on the screen. The color mode on
the screen can also be changed using a remote control unit.
(See page 5.)
* sRGB is PC input only. See page 5 for details.
H-POS
WHITE BALANCE
Adjust the horizontal position of the image.
V-POS
THRU.............. Displays the input signal level as is. (for PC
DVI-D/PC HDMI only)
PRESET ......... Selects the color temperature using PRESET.
USER.............. Used for adjusting R-CONTRAST,
G-CONTRAST, and B-CONTRAST
Adjust the vertical position of the image.
H-SIZE
Adjust the horizontal size of the image.
V-SIZE
respectively.
PRESET
Adjust the vertical size of the image.
H-RESOLUTION (PC D-SUB/PC RGB)
Selects the color temperature when the WHITE BALANCE is
set to PRESET.
The setting values are shown for reference. The color
temperature of the screen varies over time.
This function is not intended to keep the color temperature
constant.
Sets proper horizontal resolution when the resolution of
input signals is not recognized properly. (Adjustment may be
impossible with some signals.)
V-RESOLUTION (PC D-SUB/PC RGB)
R-CONTRAST
Sets proper vertical resolution when the resolution of input
signals is not recognized properly. (Adjustment may be
impossible with some signals.)
Adjusts red component when the WHITE BALANCE is set to
USER.
G-CONTRAST
RESET
Adjusts green component when the WHITE BALANCE is set
to USER.
Resets the values of the SCREEN menu items to the factory
preset values.
Select “ON” and then press MENU
.
B-CONTRAST
Adjusts blue component when the WHITE BALANCE is set
to USER.
COPY TO USER
Copies the value set for PRESET to the USER setting.
Select “ON” and then press MENU
.
GAMMA
Select a gamma value. USER sets the gamma value
transferred by the user. (See page 21.)
RESET
Resets the values of the PICTURE menu items to the factory
preset values.
Select “ON” and then press MENU
.
E
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
RS-232C/LAN SELECT
AUDIO
n
Selects the method with which to control the monitor from
the computer.
TREBLE
Adjusts the volume of treble-level sound.
ID No. SET
BASS
Assigns ID numbers to monitors connected in a daisy chain
(see page 19), using RS-232 cables.
The numbers 1 to 255 are available for ID numbers.
If “0” is set, the system regards this as the state where no ID
number is set.
Adjusts the volume of bass-level sound.
BALANCE
Adjusts the balance of the audio sound between right and left.
RESET
BAUD RATE
Resets the values of the AUDIO menu items to the factory preset values.
Selects the communication speed used for RS-232C
communication.
Select “ON” and then press MENU
.
LAN SETUP
SETUP
OSD H-POSITION
n
Configures the settings to control the monitor from the
computer via LAN. (See page 29.)
Adjusts the horizontal display position of menu screen.
OSD V-POSITION
SPEAKER SELECT
Selects the speaker to be used.
OPTION DC OUT SETTING
Adjusts the vertical display position of menu screen.
MONITOR
Normally, leave this setting as OFF.
When using an optional part, if instruction appears, change
the setting accordingly.
Select the installation direction of the monitor.
LANDSCAPE............Horizontal orientation
PORTRAIT ...............Vertical orientation
MONAURAL AUDIO
Outputs audio signals as monaural.
LANGUAGE
Sets the display language for the menu screen.
POWER ON DELAY
You can delay the screen display after the monitor is turned
on. The period can be set up to 60 seconds in units of one
second. When this function is activated, the power LED
flashes (at approx. 1 second interval) in orange. This function
is disabled when 0 is specified.
STANDBY MODE
When STANDARD is selected, startup time from standby
mode is reduced. Note, however that, more power will be
consumed in standby mode.
When LOW POWER is selected, current consumption
is reduced while the monitor is in standby mode. Note,
however, that the startup time from standby mode becomes
longer. Also, certain RS-232C commands cannot be used
in standby mode, and control via LAN will be disabled. (See
pages 22 and 29.)
HDMI SETTING
HDMI AUTO VIEW
.........................When ON is selected, the screen size is
adjusted automatically according to the
screen size control signal included in the
video signal input from the AV HDMI input
terminal.
HDMI RGB INPUT RANGE
.........................Sets the type of HDMI signals when using
the AV HDMI input mode.
When AUTO is selected, the type is set
automatically.
HOT PLUG CONTROL
Sets whether to use hot plug control for the PC/AV HDMI
and PC/AV DVI-D input terminals.
E
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
OPTION
AUTO INPUT CHANGE
n
Specify whether to change inputs automatically. When ON is
selected and no signal is present in the selected input mode,
AUTO INPUT CHANGE automatically changes the selected
mode to another mode where a video signal is present.
When video signals exist in multiple input modes, the
switching priority is as follows:
DATE/TIME SETTING
Set the date and time. Press
and time, and press
values.
Set the date in “Year/Month/Day” order.
Set the time on a 24-hour basis.
or
to select the date
or
to change the numerical
PC D-SUB, PC HDMI and AV HDMI
When the PN-ZB01 (optional) is attached:
SCHEDULE (See page 15.)
PC DVI-D, PC HDMI, PC D-SUB, PC RGB, AV DVI-D, AV
HDMI, AV COMPONENT, AV S-VIDEO and AV VIDEO
(Input mode switching may take 15 seconds or more,
depending on the connected equipment. Input signals
may not be detected properly and a priority may change,
depending on the connected equipment or video signals.)
You can set the time to switch the monitor on and off.
INPUT SELECT
Select the input mode to be used in PC/AV DVI-D input
terminal, PC/AV HDMI input terminal and PC RGB/AV
component input terminals.
AUDIO SELECT
ENLARGE (PC input)
ENLARGE H
n
Selects the terminal used to input audio signals in each input
mode.
INPUT SIGNAL (PC D-SUB/PC RGB)
Sets the number of screen splits (number of monitors) in the
horizontal direction used for the enlargement. (See page 14.)
If a computer connected to the PC D-sub/PC RGB input
terminal outputs any of the following resolutions, make a
selection from the following options.
480 LINES..........AUTO, 640x480 or 848x480
768 LINES..........AUTO, 1024x768, 1280x768, or 1360x768
1050 LINES........1400x1050 or 1680x1050
ENLARGE V
Sets the number of screen splits (number of monitors) in the
vertical direction used for the enlargement. (See page 14.)
ENLARGE-POS H / ENLARGE-POS V
ZOOM2 SPECIAL SETTING (See page 14.)
Specify the split screen to be displayed when the
enlargement function is used. (See page 14.)
SCAN MODE (AV input)
Sets the scan mode used for AV mode input.
MODE1...............Over-scan display
MODE2...............Under-scan display
MODE3...............Under-scan display when the input signal
is 1080i/p. Otherwise, over-scan display
BEZEL H / BEZEL V
Sets the frame width of the display when the enlargement
function is used.
H-POS
*
Even when MODE1 is selected, under-scan display is used when
the input signal is 1080i/p and the screen size is Dot by Dot.
Adjust the horizontal position of the enlarged screen.
V-POS
POWER MANAGEMENT
Adjust the vertical position of the enlarged screen.
POWER MANAGEMENT determines whether or not to
switch modes from no signal to the input signal standby
mode.
COLOR SYSTEM (AV S-VIDEO/AV VIDEO)
Select the color system of the AV equipment which is
connected to AV S-video and AV video input terminal. (AUTO
/ PAL / PAL-60 / SECAM / NTSC3.58 / NTSC4.43)
When AUTO is selected, the color system is automatically
set according to the input signal.
AUDIO OUTPUT
Sets the volume of sound output from the audio output
terminals.
VARIABLE ..........You can adjust the volume using VOLUME.
FIXED.................Fixes the sounds.
AUDIO INPUT LEVEL
Selects the maximum audio input level of the audio input
terminal.
SELF ADJUST
On a PC D-SUB/PC RGB screen, specify whether to
perform screen adjustment automatically or not. When ON
is selected, the screen is automatically adjusted when its
resolution is 800 x 600 or higher and the timing of input
signals changes. “ADJUSTING” appears on the screen
during the adjustment. Depending on the signal, adjustment
may not be possible. In this case select OFF. (Perform
manual adjustment of the screen.)
E
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
PIP/PbyP
Dual screen display
n
n
You can display the screens of the PC input signal and AV
input signal simultaneously.
Set this function with “PIP MODES” in the PIP/PbyP menu.
PIP MODES
Sets the display method.
OFF .........Displays one screen.
PIP...........Displays a sub screen inside a main screen.
PbyP........Displays a main screen and a sub screen in a line.
PbyP2......Displays a main screen which measures 1280 pixels
in the longest direction and a sub screen in a line.
PIP
A sub screen is displayed
inside a main screen.
Main screen
Sub
screen
PIP SIZE
Sets the size of the sub screen in PIP mode.
PbyP
PbyP2
A main screen and a sub
screen are displayed in a
line.
PIP H-POS
Main
screen
Sub
screen
Adjusts the horizontal position of the sub screen in PIP mode.
PIP V-POS
Adjusts the vertical position of the sub screen in PIP mode.
Displays a main screen
which measures 1280
pixels in the longest
direction and a sub
screen in a line.
PIP BLEND
Sub
screen
Main screen
In PIP mode, use this menu item to display the sub screen
transparently.
PIP SOURCE
Selects the input signal of the sub screen in PIP, PbyP, or
PbyP2 mode.
* The currently selected input signal is displayed on the main
screen.
* You cannot simultaneously display the screens of signals
of the same type, such as two types of PC input signals or
two types of AV input signals.
* The dual screen display cannot be used with the
combination of PC DVI-D and AV HDMI or of AV DVI-D and
PC HDMI.
SOUND CHANGE
Sets the sound which is output in PIP, PbyP, or PbyP2 mode.
If the main screen is displayed as a full screen by the AUTO
OFF function, the sound for the main screen is output even
when the sound for the sub screen is specified.
MAIN POS
Sets the position of the main screen in PbyP or PbyP2 mode.
TIPS
PbyP2 POS
• You might infringe on a copyright of the author which is
protected by copyright law when you display the images of
the computer screen and television/VCR simultaneously for
profit-making or to show the image to the public.
• The screen size for dual-screen display is the same as
the screen size for single-screen display. The Dot by Dot
screen is displayed in NORMAL size except when it is set
as the PIP main screen.
Sets the position of the sub screen in PbyP2 mode.
AUTO OFF
Sets the display method when no signals for the sub screen
are input in PIP, PbyP, or PbyP2 mode.
MANUAL....... Displays a main screen and a black sub screen.
AUTO............ Displays the main screen as a full screen.
• When dual-screen display is selected, the AUTO INPUT
CHANGE function is disabled.
TIPS
• When dual-screen display is selected, the screen cannot
be enlarged.
• When dual-screen display is selected, the INPUT SELECT
options cannot be set.
• When WHITE BALANCE is set to THRU, BLACK LEVEL,
CONTRAST, TINT, COLORS and GAMMA cannot be set.
• If COLOR MODE is set to sRGB or VIVID, the following
items cannot be set.
WHITE BALANCE, PRESET, R-/G-/B-CONTRAST, COPY
TO USER, and GAMMA
• If GAMMA is set to USER, the following items cannot be
set.
WHITE BALANCE, PRESET, R-/G-/B-CONTRAST, and
COPY TO USER
• STANDBY MODE cannot be set to LOW POWER when
SCHEDULE is effective or when OFF is selected for LED in
FUNCTION.
E
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
Enlarge
n
TIPS
• You can align several monitors and integrate them into a
• AV input signals cannot be used for the Enlarge function.
• When Enlarge is used, the AUTO INPUT CHANGE function
is disabled.
• To cancel the enlargement, set 1 for ENLARGE H and
ENLARGE V respectively.
single large screen to display.
• Up to five monitors can be aligned in both the horizontal
and vertical directions.
• Each monitor displays enlarged views of separated images.
(Example)
Horizontal direction: 2 monitors
Vertical direction: 2 monitors
ZOOM2 SPECIAL SETTING
n
If you connect a laptop computer with any of the following
screen resolutions and black bands appear around the
screen, set ZOOM2 SPECIAL SETTING of INPUT SIGNAL on
the OPTION menu to ON and then select ZOOM2 in the SIZE
setting.
This displays the area inside the black band.
Horizontal direction: 3 monitors
Vertical direction: 2 monitors
Corresponding signal*1
Laptop computer
resolution
1280x800
1280x600
1024x600
1280x1024, 1280x960, 1400x1050*2
1280x720
1024x768
Setting procedure
In the ENLARGE menu, set ENLARGE H/V and
ENLARGE-POS H/V. (See page 12.)
1. Set the number of monitors aligned in the horizontal
direction in ENLARGE H.
2. Set the number of monitors aligned in the vertical
direction in ENLARGE V.
*1: This setting is effective only when the screen resolution,
including the black band, is one of the resolutions listed
above.
*2: Use the automatic screen adjustment.
3. Set the section of the separated image to be displayed
on each monitor in ENLARGE-POS H and
ENLARGE-POS V.
In horizontal orientation
ENLARGE H
1
2
3
4
5
1
2
3
4
5
(1,1)
(2,1)
(3,1)
(4,1)
(5,1)
(1,2)
(1,3)
(1,4)
(1,5)
(2,2)
(2,3)
(2,4)
(2,5)
(3,2)
(3,3)
(3,4)
(3,5)
(4,2)
(4,3)
(4,4)
(4,5)
(5,2)
(5,3)
(5,4)
(5,5)
In vertical orientation
ENLARGE H
5
4
3
2
1
(5,1) (4,1) (3,1) (2,1) (1,1)
(5,2) (4,2) (3,2) (2,2) (1,2)
(5,3) (4,3) (3,3) (2,3) (1,3)
(5,4) (4,4) (3,4) (2,4) (1,4)
(5,5) (4,5) (3,5) (2,5) (1,5)
1
2
3
4
5
* The numbers in parentheses are the setting values in
(ENLARGE-POS H, ENLARGE-POS V) format.
E
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
Caution
SCHEDULE
n
You can set the time to switch the monitor on and off.
Set this function with “SCHEDULE” in the OPTION menu. (See
page 12.)
• Do not switch off the main power after setting the
SCHEDULE.
• Specify the correct date and time. (See page 12.)
SCHEDULE does not function unless the date and time are
specified.
• Check regularly that the set date and time are correct.
• When STANDBY MODE is LOW POWER, SCHEDULE
cannot be set.
PC D-SUB
SCHEDULE
XXXX/XX/XX XXX XX:XX:XX
No.
(1) POWER (2)
DAY OF THE WEEK (3)
TIME(4)
INPUT (5)
TIPS
• Up to 8 SCHEDULE items can be registered.
• Setting the SCHEDULE flashes the power LED alternately
in red and orange in standby mode.
• A SCHEDULE that has a large number has precedence
over that of a small number when schedules overlap.
…
OK [MENU]
1 9 2 0 x 1 0 8 0
V: 60 Hz H: 67.5 kHz
1. Press
press
2. Set the SCHEDULE. (See the description below.)
Press or to select items, and press or
change the setting.
3. Press MENU
SCHEDULE becomes effective.
or
to select the SCHEDULE number, and
.
to
.
(1)
●: SCHEDULE effective
: SCHEDULE not effective
(2) POWER
ON : Switches the monitor on at the specified time.
-
OFF : Switches the monitor off at the specified time and puts
the monitor in standby mode.
(3) DAY OF THE WEEK
Specifies the day of the week to execute the SCHEDULE.
ONLY ONCE:
Executes the SCHEDULE once on the specified day.
Specify the day of the week to execute the SCHEDULE.
EVERY WEEK:
Executes the SCHEDULE on the specified day of the week
every week. Specify the day of the week to execute the
SCHEDULE.
Periodic setting such as “Monday through Friday” is also
possible.
EVERY DAY:
Executes the SCHEDULE every day regardless of the day
of the week.
(4) TIME
Specifies the time to execute the SCHEDULE.
Set the time on a 24-hour basis.
(5) INPUT
Specifies the input mode at power-on. When not specifying,
the screen at the previous power-off appears.
Input modes displayed on DVI, HDMI and BNC depend on
INPUT SELECT settings.
E
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items
ADVANCED items (AV input) (See page 10
n
Adjustments for PC screen display
for additional Menu item details.)
Automatic adjustment
n
FLESH TONE
Adjust the hue control.
3D-NR
When you use the PC D-sub input terminal or PC RGB input
terminals to display a PC screen for the first time, or when
you change the setting of the PC, use the automatic screen
adjustment.
Reduce the noise of playback images on video.
Setting a higher level reduces more noise. However, it may
cause blurring on an image.
1. Switch the input to PC D-SUB or to PC RGB and display
the adjustment pattern. (See the description below.)
2. Press MENU and use
menu.
or
to display the SCREEN
MPEG-NR
Reduce block noise caused by digital compression.
3D-Y/C (AV VIDEO)
3. Press
4. Press
and select “AUTO”.
.
Specify whether to perform 3-dimension Y/C separation.
If dot interference or cross-color is occurring in fast-motion
scenes, selecting “OFF” may improve the image quality.
The automatic adjustment is complete in several seconds.
5. Press MENU twice to close the menu screen.
C.M.S.-HUE
Adjusts color tone with 6 colors of R (red), Y (yellow), G
(green), C (cyan), B (blue), and M (magenta).
TIPS
• If the screen cannot be adjusted properly with one
automatic adjustment, repeat the automatic adjustment two
or three times. Try manual adjustment if necessary.
C.M.S.-SATURATION
Adjusts color vividness with 6 colors of R (red), Y (yellow), G
(green), C (cyan), B (blue), and M (magenta).
C.M.S.-VALUE
Screen display for adjustment
n
Adjusts color brightness with 6 colors of R (red), Y (yellow),
G (green), C (cyan), B (blue), and M (magenta).
Before making adjustments in the SCREEN menu or
PICTURE menu, display an image to brighten the entire
screen. If you are using a Windows PC, use the adjustment
pattern on the supplied CD-ROM.
TIPS
• When FLESH TONE is set to LOW or HIGH, C.M.S.-HUE/
-SATURATION/-VALUE cannot be set.
Opening the adjustment pattern
The following example is performed in Windows XP.
1. Load the supplied CD-ROM into the computer’s CD-
ROM drive.
2. Open the CD-ROM in [My Computer].
3. Double-click [Adj_uty.exe].
The adjustment pattern will appear.
Adjust the screen automatically or manually.
4. When adjustment is finished, press the [Esc] on the
computer’s keyboard to quit the adjustment program.
5. Eject the CD-ROM from the CD-ROM drive.
TIPS
• If the display mode on the computer you are using is
65,000 colors, the color levels in the color pattern may
appear differently or grayscale may appear to be colored.
(This is due to the specifications of the input signal and is
not a malfunction.)
E
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
You can return the settings to their factory-preset values and
restrict operations.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF .............. Do not notify about an abnormal
temperature.
SIZE
1. After pressing
for about 5 seconds, press
in that order.
,
,
, and
OSD & LED .. When an abnormal temperature is
detected, the power LED flashes in red
and green alternately and the screen
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is
detected, the power LED flashes in red
and green alternately.
1/1
FUNCTION
ALL RESET
OFF
UNLOCKED
ON
ADJUSTMENT LOCK
RS-232C
OSD DISPLAY
ON
LED
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
CONTROLLER INPUT
STATUS ALERT
OFF
MONITOR
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the
power LED flashes in red and the screen
displays a message: STATUS [xxxx].
…
END [MENU]
2. Select and set the items.
ALL RESET
LED............... When a hardware error is detected, the
power LED flashes in red.
Resets the settings to the factory default settings.
Press
, select ALL RESET, and then press MENU
POWER BUTTON
.
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
After initialization, turn the main power switch off and
then back on.
When the PN-ZB01 (optional) is attached, press
select the resetting method, and then press MENU
,
CONTROLLER INPUT
.
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
ALL RESET1 ....Resets all the settings to the factory
default settings.
ALL RESET2 ....Returns all settings to the factory default
settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT,
ID No. SET, BAUD RATE, NETWORK,
MAIL, SERVICE & SUPPORT, and
SNMP (See page 11, and pages 33 to
36.)
3. Press MENU to return to the normal screen.
TIPS
• When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
1.........Disables all operations other than turning power
on/off and FUNCTION.
2.........Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not
even power on/off).
RS-232C
(RS-232C/LAN when the PN-ZB01 (optional) is
attached)
Specifies whether to allow control via RS-232C or LAN
(see pages 18 and 29).
OSD DISPLAY
Hides/shows menus.
The FUNCTION screen cannot be hidden.
LED
Specifies whether to light the power LED.
OFF cannot be selected when STANDBY MODE is LOW
POWER.
E
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
You can control this monitor from a PC via RS-232C (COM
port) on the PC.
Communication conditions
You can also connect multiple monitors via a daisy chain by
using a PC. By assigning ID numbers to each monitor (see
page 19), you can make input mode selection/adjustment or
can check the status of a specific monitor.
Set the RS-232C communication settings on the PC to match
the monitor’s communication settings as follows:
Baud rate
Data length
Parity bit
*
Stop bit
1 bit
8 bits
None
Flow control
None
Precautions when the PN-ZB01 (optional) is attached
• To control the monitor via RS-232C, set RS-232C/LAN
SELECT to RS-232C.
* Set to the same baud rate as the BAUD RATE setting of
SETUP menu. (Initial setting: 9600 bps)
• You cannot use RS-232C and LAN control simultaneously.
* When connecting multiple monitors in a daisy chain, set all
monitors to the same BAUD RATE.
PC connection
One-to-one connection with a PC
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the monitor.
n
Communication procedure
Command format
n
When a command is sent from the PC to the monitor, the
monitor operates according to the received command and
sends a response message to the PC.
Return code
C1 C2 C3 C4 P1 P2 P3 P4
RS-232C input terminal
Parameter field
(4 character string comprised of:
Command field
(4 prescribed
alphanumerical characters)
PC
Example: VOLM0030
To COM port
VOLM
30
* Be sure to input 4 characters for the parameter. Pad with
spaces (“ ”) if necessary.
RS-232 straight cable
(commercially available)
H
H
H
(“
” is a return code (0D , 0A or 0D ))
Wrong : VOLM30
Right : VOLM
Advanced operation
Daisy chain connection…
n
30
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the first monitor.
When inputting a negative value, specify a numerical value in
three digits.
Next, connect RS-232 straight cable to the first monitor’s
RS-232C output terminal and to the second monitor’s
RS-232C input terminal. Connect in the same way to the third
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the
length of the cable used and the surrounding environment.)
Example: AUTR-009
Do not use spaces for MPOS, DATE, and SC01 through
SC08. Specify parameters using a specified number of
characters.
Example: MPOS010097
First monitor
Second monitor
If a command has “R” listed for “DIRECTION” in the
“RS-232C command table” on page 22, the current value can
be returned by using “?” as the parameter.
RS-232C
output terminal
Example:
From PC to monitor (How much
is current volume setting?).
VOLM ? ? ? ?
←
←
RS-232C
input terminal
From monitor to PC (Current
volume setting: 30).
30
* If an ID number (see page 19) has been assigned
(For example, ID number = 1).
PC
From PC to monitor.
From monitor to PC.
VOLM
30
?
←
←
001
RS-232 straight cables
To COM port
E
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
Communication interval
Response code format
n
n
When a command has been executed correctly
• After OK or ERR is returned, you must send the following
commands.
O
K
Return code
To set a timeout for the command response, specify 10
seconds or longer.
When connecting multiple monitors in a daisy chain, set the
timeout to at least the product of the monitor’s position from
the computer multiplied by 10 seconds.
Example) 3rd monitor from computer: 30 seconds or longer.
• Provide an interval of 100 ms or more between the
command response and the transmission of the next
command.
A response is returned after a command is executed.
* If an ID number has been assigned
Return code
Space (20H)
(0DH, 0AH)
O
K
SPC
0
0
1
ID number of responding monitor
VOLM0020
OK
When a command has not been executed
Interval of 100 ms or more
E
R
R
Return code
INPS0001
WAIT
* If an ID number has been assigned
Return code
(0DH, 0AH)
Space (20H)
TIPS
E
R
R
SPC
0
0
1
• When executing ALL RESET, set the timeout period to 30
seconds or longer.
• When turning the power on while the POWER ON DELAY
function is in use, set the timeout period to the POWER ON
DELAY period + 10 seconds or longer.
TIPS
• “ERR” is returned when there is no relevant command or
when the command cannot be used in the current state of
the monitor.
Advanced operation
• If communication has not been established for reasons
such as a bad connection between the PC and monitor,
nothing is returned (not even ERR).
This section explains commands for daisy chain connection.
The basic communication procedure is the same as in the
“One-to-one connection with a PC” section.
• If no monitor has been assigned the designated ID number
(e.g. if the command IDSL0002
with ID number: 2 is found), no response is returned.
is used, but no monitor
ID numbers
n
You can assign a unique ID number to each monitor (see
page 11). This allows you to control a particular monitor in a
daisy chain of monitors.
You can assign ID numbers either from the menu screen (using
the remote control) or from the PC using RS-232 cable.
[Example]
If execution of the command is taking some time
W
A
I
T
Return code
When the following commands are used, “WAIT” is returned.
In this case, a value will be returned if you wait a while. Do not
send any command during this period.
ID number: 1 ID number: 2 ID number: 3 ID number: 4
No ID number is attached to WAIT response.
• Commands which return WAIT:
1. When repeater control is used
If monitors are connected as shown above, you can
execute commands like “Set the volume of the monitor with
ID 4 to 20”.
2. When an IDSL or IDLK command is used
3. When one of the following commands is used: RSET,
INPS, ASNC, WIDE, EMAG, EPOS, PXSL, POWR,
AGIN, MWIN, MWIP, MWPP, ESTG, EMHV, EPHV,
ESHV
When controlling monitors linked in a daisy chain by
designating ID numbers, you should basically avoid any
duplication of ID numbers.
ID numbers do not have to be assigned in ascending order
starting from the PC. They can also be connected as shown
below.
When control via RS-232C is locked (to prevent use)
using the operation lock function (see page 17)
L
O
C
K
E
D
Return code
[Example]
ID number: 3 ID number: 2 ID number: 4 ID number: 1
When RS-232C/LAN SELECT is set to LAN
U
N
S
E
L
E
C
T
E
D
Return code
(0DH, 0AH)
E
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
IDLK ........The parameter of this command sets the ID
number of the monitor. The monitor is subject to all
subsequent commands.
Commands for ID control
The command examples shown on this page assume the
following connection and ID number set up.
n
ID number: 1 ID number: 2 ID number: 3 ID number: 4
Example:
Following commands are for the monitor
with ID number: 2.
IDLK0002
WAIT
←
Searching for monitor with ID number:
2
←
←
←
←
IDST .........A monitor receiving this command sets its own ID
Found monitor with ID number: 2
OK
002
number in the parameter field.
Sets volume of monitor with ID
number: 2 to 30.*
Example:
IDST0001
VOLM0030
WAIT
Processing
The ID number of this monitor is set to 1.
OK
001
←
OK
002
Sets volume of monitor with ID
number: 2 to 20.*
VOLM0020
WAIT
←
TIPS
You can automatically assign ID numbers by using the IDST
command with the Repeater control (see “Repeater control”
on page 21).
For example, using the command “IDST001+” automatically
sets the ID numbers, as shown below.
[Example]
OK
002
Canceling fixed ID number setting
Canceling IDLK
IDLK0000
WAIT
←
←
←
Cancelation complete
OK
002
VOLM0010
ID number: 1 ID number: 2 ID number: 3 ID number: 4
The volume of the monitor with ID number:
1 (the one directly connected to the PC) is
set to 10. (IDLK is canceled.)
OK
001
←
* The IDLK command remains effective until it is
canceled, or power is shut off.
ID setting command with repeater control
IDST001 +
WAIT
←
IDCK........Provides screen display of the ID number currently
assigned to a monitor, and the ID number currently
set for IDLK (if any).
“OK” response from ID number: 1
“OK” response from ID number: 2
“OK” response from ID number: 3
“OK” response from ID number: 4 (End)
OK
OK
OK
OK
001
002
003
004
←
←
←
←
Example:
(After executing IDLK0002)
IDCK0000
(Parameter has no meaning.)
←
←
←
IDSL ........The parameter of this command sets the ID number
of the monitor. The monitor is subject to the next
command.
Returned response. The ID
number is also displayed on the
monitor screen.
ID : 001 IDLK : 002
Example:
Repeater control. (If a command
is used with repeater control, ID
designation using IDSL or IDLK
is canceled.)
IDCK000 +
The next command is for the monitor
with ID number: 2.
IDSL0002
WAIT
←
WAIT
ID : 001 IDLK : 000
ID : 002 IDLK : 000
ID : 003 IDLK : 000
ID : 004 IDLK : 000
Searching for monitor with ID number:
2
←
←
←
←
←
←
Found monitor with ID number: 2
OK
002
Sets volume of monitor with ID
number: 2 to 30.
VOLM0030
WAIT
Processing
OK response from monitor with ID
number: 2
OK
VOLM0020
OK 001
002
Sets volume to 20.
The volume of the monitor with ID
number: 1 (the one directly connected
to the PC) is set to 20.*
←
* The IDSL command is effective only once, for the
immediately succeeding command.
E
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
Repeater control
n
Setting of the GAMMA user data
This system has a function to allow setting of multiple
monitors connected in a daisy chain using a single command.
This function is called repeater control. You can use Repeater
control function without assigning ID numbers.
To transfer the GAMMA user data
n
Use the user data transfer commands (UGRW, UGGW and
UGBW). For each of the R, G and B colors, divide the total
512 pieces of user data into 16 blocks, and transfer 32 pieces
of data with each command.
[Example]
Set 1
Set 2
Set 3
Set 4
…
C1 C2 C3 C4 P1 P2 P3 P4
S1 S2
Command field Block number (01 to 16) Data field Checksum field
* If monitors are connected as shown above, you can
execute a command like “Set all monitors’ input settings to
PC D-SUB”.
Example: To transfer the data of block 1 (0 to 31 levels)
of red (R) data
UGRW01000000010002 … 0031C0
Repeater control command
Repeater control is achieved by setting the FOURTH
n
One piece of data consists
of 4 digits.
CHARACTER of the parameter to “+”.
Example:
* If data is less than 4 digits, add a “0” (zero) to make it 4
digits.
Sets volume of all monitors to 30.
VOLM030 +
←
* The checksum field is the character string (ASCII) data of
lower-order one byte which indicates the sum of the block
number and 32 pieces of data in hexadecimal (0 to F).
In repeater control, responses are returned by all the
connected monitors.
If you want to determine that a value has been returned by a
specific set, assign ID numbers to each monitor in advance.
When some monitors do not return their responses, the
probable cause is that the monitors could not receive the
command or command processing is not complete. Do not
send a new command.
Saving the GAMMA user data
n
Use the user data save command (UGSV) to save the
transferred user data in the monitor.
If the data is not saved, it will be cleared when:
• The main power switch is off
• STANDBY MODE is LOW POWER and the monitor enters
standby mode
Example: (When 4 monitors are connected, and
assigned ID numbers: 1 through 4)
VOLM030 +
WAIT
Activating the GAMMA user data
To activate the transferred user data, select USER for GAMMA
of the PICTURE menu, or send the corresponding RS-232C
command.
n
OK
OK
OK
OK
001
002
003
004
Checking the GAMMA user data
n
←
If 4 monitors are connected in
a chain, reliable operation can
be ensured by sending a new
command only after a reply
has been returned by 4th (last)
monitor.
Use the user data read commands (UGRR, UGGR and
UGBR) to return 512 pieces of user data for each of the R,
G and B colors. Divide the data into 16 blocks and return 32
pieces of data with each command. The value to be returned
is not the value stored in the monitor, but the value in the
temporary memory for display. (These values are the same
when the user data save command (UGSV) above has been
sent.)
Repeater control can also be used for reading settings.
Example:
VOLM ? ? ? +
WAIT
TIPS
• The user data is not initialized by RESET of the PICTURE
menu. To initialize the user data, use ALL RESET of the
FUNCTION menu.
The GAMMA user data initialize command (UGRS) allows
the initialization of the user data only.
10
20
30
30
001
002
003
004
Volume settings for all
monitors are returned.
TIPS
• If repeater control is used during ID designation (IDSL,
IDLK), the ID designation is canceled.
E
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
RS-232C command table
How to read the command table
Command:
Direction:
Command field (See page 18.)
W When the “Parameter” is set in the parameter field (see page 18), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
(repeater control) in the parameter field (see page 18).
Parameter field (See page 18.)
Response (Returned value)
“●” indicates a command which can be used in power standby mode regardless of the STANDBY MODE
setting.
?” or “???+”
Parameter:
Reply:
*1:
“○” indicates command which can be used in power standby mode when STANDBY MODE is set to
STANDARD. (It cannot be used in the power standby mode when LOW POWER is selected.)
“–” indicates a command which cannot be used in power standby mode.
PN-ZB01 (optional) limitations
*2:
(A) When PN-ZB01 (optional) is not attached, (B) When PN-ZB01 (optional) is attached.
○ : The command can be used.
- : Error (ERR)
Power control/Input mode selection
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
Switches to standby mode.
*1
(A) (B)
POWER CONTROL
POWR
W
0
1
Returns from standby mode.
Standby mode
R
0
1
2
● ○ ○
○ ○
Normal mode
Input signal waiting mode
INPUT MODE SELECTION
INPS
W
0
1
Toggle change for input mode. Terminals not selected in INPUT SELECT
cannot be selected.
PC DVI-D
-
○
“ERR” when AV DVI-D is selected for DVI of INPUT SELECT.
2
3
PC D-SUB
○ ○
AV COMPONENT
“ERR” when PC RGB is selected for BNC of INPUT SELECT.
-
○
4
6
AV VIDEO
-
○
PC RGB
●
-
○
“ERR” when AV COMPONENT is selected for BNC of INPUT SELECT.
7
AV DVI-D
-
○
“ERR” when PC DVI-D is selected for DVI of INPUT SELECT.
8
9
AV S-VIDEO
-
○
AV HDMI
○ ○
“ERR” when PC HDMI is selected for HDMI of INPUT SELECT.
10
PC HDMI
○ ○
“ERR” when AV HDMI is selected for HDMI of INPUT SELECT.
R
1
2
3
4
6
7
8
9
PC DVI-D
PC D-SUB
AV COMPONENT
AV VIDEO
PC RGB
● ○ ○
AV DVI-D
AV S-VIDEO
AV HDMI
10 PC HDMI
SCREEN menu
*2
*1
Function
Command
Direction
Parameter
Reply
Control/Response contents
When the input mode is PC D-SUB, PC RGB.
(A) (B)
AUTO
ASNC
CLCK
W
1
CLOCK
WR
0-1200
0-1200 When the input mode is PC D-SUB, PC RGB.
Varies depending on the signal.
PHASE
PHSE
HPOS
WR
WR
0-63
0-63 When the input mode is PC D-SUB, PC RGB.
POSITIONING
POSITION OF
THE LONGEST
DIRECTION
0-100
0-100 0-800 on PC D-SUB, PC RGB.
Varies depending on the signal.
POSITION OF
THE SHORTEST
DIRECTION
VPOS
HSIZ
WR
WR
WR
WR
WR
W
0-100
0-100
0-100 0-200 on PC D-SUB, PC RGB.
Varies depending on the signal.
SIZE
POSITION OF
THE LONGEST
DIRECTION
0-100
0-100
-
○ ○
POSITION OF
THE SHORTEST
DIRECTION
VSIZ
0-100
RESOLUTION
LONGEST
DIRECTION
RESOLUTION
HRES
VRES
ARST
300-1920
200-1200
1
300-1920 When the input mode is PC D-SUB, PC RGB.
Only even numbers are valid for parameters.
Varies depending on the signal.
SHORTEST
DIRECTION
RESOLUTION
200-1200
RESET
E
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
PICTURE menu
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
AUTO
AGIN
W
1
When the input mode is PC D-SUB, PC RGB.
-
CONTRAST
BLACK LEVEL
TINT
CONT
BLVL
WR
WR
WR
WR
WR
WR
WR
WR
WR
WR
0-60
0-60
0-60
0-60
0-24
0-2
0-60 0-127 on PC D-SUB, PC RGB.
0-60 0-127 on PC D-SUB, PC RGB.
TINT
0-60
○
○
COLORS
SHARPNESS
COLR
SHRP
FLES
0-60
○
0-24
ADVANCED
(When the input
mode is AV.)
FLESH TONE
3D-NR
0-2 0: OFF, 1: LOW, 2: HIGH
0-2 0: OFF, 1: LOW, 2: HIGH
0-1 0: OFF, 1: ON
TDNR
MPNR
YCSP
CMHR
CMHY
CMHG
CMHC
CMHB
CMHM
CRST
CMSR
CMSY
CMSG
CMSC
CMSB
CMSM
CRST
CMVR
CMVY
CMVG
CMVC
CMVB
CMVM
CRST
BMOD
0-2
MPEG-NR
3D-Y/C
0-1
0-1
0-1 0: OFF, 1: ON (When the input mode is AV VIDEO)
-
C.M.S.-HUE
-10-10
-10-10
R
Y
G
C
B
M
W
1
Resets the hue.
C.M.S.-
SATURATION
WR
-10-10
-10-10
R
Y
G
C
○
B
M
○
W
2
Resets the saturation.
C.M.S.-VALUE
WR
-10-10
-10-10
R
Y
G
C
○
B
M
W
3
Resets the brightness.
COLOR MODE
WR
0
2
0
2
3
0
STD
VIVID
○
3
sRGB (When the input mode is PC)
When the input mode is PC DVI-D/PC HDMI.
WHITE BALANCE THRU
PRESET
CTMP
WR
0
1-17
1-17 From 1: approximately 3,000K to 15: approximately 10,000K
(500K steps)
16: approximately 5,600K, 17: approximately 9,300K
○
USER
99
0-256
0-256
0-256
0
99
R-CONTRAST
G-CONTRAST
B-CONTRAST
CRTR
CRTG
CRTB
CPTU
GAMM
WR
WR
WR
W
0-256 “ERR” when CTMP is not set to 99.
0-256
0-256
COPY TO USER
GAMMA
Copies a preset value to the user setting.
0-2 0: 1.8, 1: 2.2, 2: 2.4
4-5 4: USER, 5: 2.0
-
WR
0-2
○
4-5
RESET
ARST
W
2
-
AUDIO menu
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
TREBLE
BASS
AUTR
AUBS
AUBL
ARST
WR
WR
WR
W
-5-5
-5-5
-5-5
-5-5
○
○ ○
BALANCE
RESET
-10-10
3
-10-10
-
E
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
SETUP menu
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
OSD H-POSITION
OSDH
OSDV
STDR
MONO
LANG
WR
WR
WR
WR
WR
0-100
0-100
0-100
0-1 0: LANDSCAPE, 1: PORTRAIT
○
OSD V-POSITION
MONITOR
0-100
0-1
0-1
14
1
○
○
MONAURAL AUDIO
LANGUAGE
0-1 0: OFF, 1: ON
14 ENGLISH
1
2
3
4
5
6
0
DEUTSCH
FRANÇAIS
ITALIANO
ESPAÑOL
РУССКИЙ
2
3
○
4
○ ○
5
6
POWER ON DELAY
PWOD
STBM
WR
WR
0
OFF
○
○
1-60
0-1
1-60 ON
STANDBY MODE
HDMI SETTING
0-1 0: STANDARD, 1: LOW POWER
(“ERR" when SCHEDULE is effective or OFF is selected for LED.)
HDMI AUTO VIEW HDAW
WR
WR
0-1
0-2
0-1 0: OFF, 1: ON
○
○
HDMI RGB INPUT HDRA
RANGE
0-2 0: AUTO, 1: FULL, 2: LIMITED
HOT PLUG CONTROL (DVI)
HOT PLUG CONTROL (HDMI)
RS-232C/LAN SELECT
HPCT
HPCH
CTLS
IDST
WR
WR
WR
W
0-1
0-1
0-1 0: OFF, 1: ON
-
○
0-1 0: OFF, 1: ON
○ ○ ○
○
0-1
0-1 0 : RS-232C 1 : LAN
-
○
ID NUMBER
ID NO. SETTING
0-255
Sets the monitor’s ID number. (“0” means “no ID number”.)
0-255 Returns the monitor’s ID number.
R
ID NO. SETTING
(ONCE)
IDSL
IDLK
IDCK
W
1-255
Sets a monitor ID number.
This ID number is only effective for the command immediately after this
command.
0
Clears the ID number if one has been designated.
○ ○ ○
ID NO. SETTING
(SUBSEQUENT)
W
W
1-255
Sets a monitor ID number.
This ID number is effective for the next and all subsequent commands
after this command.
0
0
Clears the ID number if one has been designated.
ID CHECK
ID
: xxx
Displays monitor’s own ID number and the selected ID number on the
screen.
IDLK : yyy
BAUD RATE
BAUD
SPSL
DCOT
WR
WR
WR
0-2
0-1
0-2
0-2 0: 9600bps, 1: 19200bps, 2: 38400bps
0-1 0: Internal speaker, 1: External speaker
0-2 0: OFF, 1: MODE1, 2: MODE2
○ ○ ○
SPEAKER SELECT
-
○
○
○ ○
OPTION DC OUT SETTING
-
E
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
OPTION menu
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
DATE/TIME SETTING
SCHEDULE
DATE
WR
WR
AABBCCDDEE
ABCDEFFGGH
AABBCCDDEE
ABCDEFFGGH
AA: Year, BB: Month, CC: Day, DD: Time, EE: Minute
○
SC01-
SC08
Schedule of a specified number
A: Schedule
B: Power
0= Not effective, 1 = Effective
0 = OFF, 1 = ON
C: Day of the week 1 0 = Only once, 1 = Every week, 2 = Every day
D: Day of the week 2 0 = Sunday, 1 = Monday through 6 = Saturday,
9 = Not exist
E: Day of the week 3 0 = Sunday, 1 = Monday through 6 = Saturday,
9 = Not exist
○ ○
○
F: Time
00-23
G: Minute
H: Input
00-59
0 = Not specified, 1 = PC DVI-D/AV DVI-D,
2 = PC D-SUB, 3 = PC RGB/AV COMPONENT,
4 = AV VIDEO, 5 = AV S-VIDEO,
6 = PC HDMI/AV HDMI
“ERR” when LOW POWER is selected for STANDBY MODE.
INPUT SELECT
AUDIO SELECT
DVI
DVSL
BNSL
HDSL
ASDP
ASAP
WR
WR
WR
WR
WR
0-1
0-1 0: PC DVI-D, 1: AV DVI-D
0-1 0: PC RGB, 1: AV COMPONENT
0-1 0: PC HDMI, 1: AV HDMI
1-3 1: AUDIO, 2: AUDIO 1, 3: AUDIO 2
1-3 1: AUDIO
-
-
○
○
BNC
0-1
0-1
1-3
1-3
HDMI
○ ○
PC DVI-D
PC D-SUB
-
○
-
2: AUDIO 1, 3: AUDIO 2
PC HDMI
ASHP
WR
0-1
2-3
1-3
1-3
0-1
2-3
1-3
1-3
1-3
0-1 0: HDMI, 1: AUDIO
○
-
2-3 2: AUDIO 1, 3: AUDIO 2
○
PC RGB
AV DVI-D
AV HDMI
ASCP
ASDA
ASHA
WR
WR
WR
1-3 1: AUDIO, 2: AUDIO 1, 3: AUDIO 2
1-3 1: AUDIO, 2: AUDIO 1, 3: AUDIO 2
0-1 0: HDMI, 1: AUDIO
-
○
-
○
-
2-3 2: AUDIO 1, 3: AUDIO 2
AV COMPONENT ASCA
WR
WR
WR
R
1-3 1: AUDIO, 2: AUDIO 1, 3: AUDIO 2
1-3 1: AUDIO, 2: AUDIO 1, 3: AUDIO 2
1-3 1: AUDIO, 2: AUDIO 1, 3: AUDIO 2
-
AV S-VIDEO
AV VIDEO
ASSA
ASVA
-
-
INPUT
RESOLUTION
(PC)
RESOLUTION CHECK PXCK
-
1
2
3
5
6
7
8
9
Returns current resolution in the form of hhh, vvv.
768) 1360 x 768
PIXEL SETTING
(PC D-SUB, PC
RGB)
PXSL
WR
1
2
768) 1280 x 768
3
768) 1024 x 768
5
480) 848 x 480
-
6
480) 640 x 480
7
1050) 1680 x 1050
1050) 1400 x 1050
768) AUTO
8
○ ○
9
10
10 480) AUTO
INPUT RESOLUTION (AV) RESOLUTION CHECK RESO
R
-
480i, 480p, 1080i, 720p, 1080p, VGA , etc.
-
ZOOM2 SPECIAL SETTING
(PC D-SUB, PC RGB)
Z2SP
WR
0-1
0-1 0: OFF, 1: ON
○
SCAN MODE
SCAN
PMNG
PMAV
CSYS
AOUT
AIVP
WR
WR
WR
WR
WR
WR
WR
WR
0-2
0-1
0-1
0-5
0-1
0-1
0-1
0-1
0-2 0: MODE1, 1: MODE2, 2: MODE3 (When the input mode is AV)
0-1 0: OFF, 1: ON
○
○
○
○
○
○
○
○
POWER MANAGEMENT (PC)
POWER MANAGEMENT (AV)
COLOR SYSTEM
0-1 0: OFF, 1: ON
0-5 0: AUTO, 1: PAL, 2: PAL-60, 3: SECAM, 4: NTSC3.58, 5: NTSC4.43
0-1 0: VARIABLE, 1: FIXED
-
○
AUDIO OUTPUT
AUDIO INPUT LEVEL
SELF ADJUST
0-1 0: 1.0Vrms, 1: 0.5Vrms
○ ○
AADJ
AINC
0-1 0: OFF, 1: ON
AUTO INPUT CHANGE
0-1 0: OFF, 1: ON
E
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
ENLARGE menu (When the input mode is PC)
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
0-4 0: OFF, 1: 2 x 2, 2: 3 x 3, 3: 4 x 4, 4: 5 x 5
*1
(A) (B)
ENLARGE MODE
EMAG
EMHV
WR
WR
0-4
11-55
11-55 1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are
the numbers of monitors specified for the longest direction and the
shortest direction respectively.)
BEZEL WIDTH
WIDTH OF THE
SHORTER SIDE
BEZH
BEZV
EPHV
WR
WR
WR
0-100
0-100
11-55
0-100
WIDTH OF THE
LONGER SIDE
0-100
IMAGE POSITION (M x N)
11-55 Specifies values in the order of ENLARGE POSITION IN LONGEST/
SHORTEST DIRECTION.
IMAGE POSITION (2 x 2)
IMAGE POSITION (3 x 3)
IMAGE POSITION (4 x 4)
IMAGE POSITION (5 x 5)
EPOS
EPOS
EPOS
EPOS
EPSH
WR
WR
WR
WR
WR
0-3
0-8
0-3 See the description below.
-
○ ○
0-8
0-15
0-24
0-15
0-24
ENLARGED
SCREEN
THE LONGEST
DIRECTION
-999-999
-999-999 The setting range depends on the ENLARGE MODE setting and the
IMAGE POSITION.
POSITIONING
THE SHORTEST
DIRECTION
EPSV
WR
WR
WR
-999-999
XXYY
-999-999
ENLARGE/IMAGE POSITION SETTING ESTG
XXYY XX: ENLARGE MODE (Same as EMAG), YY: IMAGE POSITION (Same
as EPOS)
ESHV
XXYY
XXYY XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same
as EPHV)
• IMAGE POSITION (EPOS) setting
In horizontal orientation
2 x 2
3 x 3
4 x 4
5 x 5
0
1
3
0
3
6
1
4
7
2
5
8
0
4
3
7
0
5
1
3
4
2
7
1
5
2
6
2
6
8
9
8
9
10
14
11
15
10
15
20
11
16
21
12
17
22
13
18
23
14
19
24
13
12
In vertical orientation
2 x 2
3 x 3
4 x 4
5 x 5
2
0
6
7
8
3
4
5
0
12
8
4
5
6
7
0
20
15
10
5
6
7
8
9
0
1
1
2
9
21
16
17
18
19
11
12
13
14
13
1
3
1
14
2
22
2
10
11
23
24
3
4
15
3
E
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
PIP/PbyP menu
*2
Function
Command
Direction
Parameter
0-3
Reply
Control/Response contents
*1
(A) (B)
PIP MODES
PIP SIZE
MWIN
MPSZ
MHPS
WR
WR
W
0-3 0: OFF, 1: PIP, 2: PbyP, 3: PbyP2
1-12
○
○
○
○
○
○
1-12
PIP POS
THE LONGEST
0-100
DIRECTION
R
0-100
0-100
THE SHORTEST
DIRECTION
MVPS
MPOS
W
0-100
○ ○
R
PIP POS LD+SD BATCH
W
0-100,0-100
Specify the position in MPOSxxxyyy format.
(xxx: Longer side, yyy: Shorter side position)
○
R
0-100,0-100 Returns a response in (xxx,yyy) format.
(xxx: Longer side, yyy: Shorter side position)
○
○
PIP BLEND
MWBL
MWIP
WR
WR
0-15
1
0-15
PIP SOURCE
1
2
3
4
6
7
8
9
PC DVI-D
-
○
2
PC D-SUB
AV COMPONENT
AV VIDEO
PC RGB
○ ○
-
3
○
4
-
○
6
-
○
○
7
AV DVI-D
-
○
8
AV S-VIDEO
AV HDMI
-
○
9
○ ○
-
10
1-2
0-1
0-2
0-1
10 PC HDMI
○
SOUND CHANGE
MAIN POS (Main screen)
PbyP2 POS (Sub screen)
AUTO OFF
MWAD
MWPP
MW2P
MOFF
WR
WR
WR
WR
1-2 1: MAIN, 2: SUB
○
○
○
○
0-1 0: POS1, 1: POS2
0-2 0: POS1, 1: POS2, 2: POS3
0-1 0: MANUAL, 1: AUTO
○ ○
Initialization/Functional Restriction Setting (FUNCTION) menu
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
ALL RESET
RSET
W
0
0: ALL RESET
0: ALL RESET 1, 1: ALL RESET 2
0-2 0: OFF
-
-
○
0-1
0-2
0-1
0-1
-
-
○
ADJUSTMENT LOCK
OSD DISPLAY
LED
ALCK
LOSD
OFLD
WR
WR
WR
○
○
0-1 0: ON, 1: OFF
0-1 0: ON, 1: OFF
○
“ERR” when LOW POWER is selected for STANDBY MODE.
○ ○
TEMPERATURE ALERT
STATUS ALERT
TALT
SALT
PBTN
PCIP
WR
WR
WR
WR
0-2
0-2
0-1
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
0-1 0: MONITOR, 1: CONTROLLER
○
○
○
POWER BUTTON
CONTROLLER INPUT
0-2 0: D-SUB, 1: HDMI (“ERR” when MONITOR is selected for POWER
○ ○ ○
BUTTON.)
2: DVI-D (“ERR” when MONITOR is selected for POWER BUTTON.)
-
○
○
E
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (RS-232C)
Others
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
SCREEN SIZE (PC)
WIDE
WIDE
VOLM
MUTE
INF1
WR
WR
WR
WR
R
1-5
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
○
○
○
-
SCREEN SIZE (AV)
VOLUME
1-5
0-31
0-1
0-31
0-1 0: OFF, 1: ON
Value
MUTE
INFORMATION
MODEL
●
○
SERIAL NO
SRNO
VLMP
DSTA
R
Value
BRIGHT
WR
R
0-31
0-31
TEMPERATURE SENSOR
0
1
2
Internal temperature normal
Internal temperature abnormal (Standby mode)
Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operation.)
●
○
3
4
Internal temperature abnormal (Brightness of the backlight decreases.)
Temperature sensor abnormal
○ ○
TEMPERATURE ACQUISITION
ERRT
STCA
R
Value Temperature at temperature sensors 1 through 3 are returned in the
following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE
W
R
0
Initialization
0
1
2
3
4
6
8
No detectable error has occurred
Standby mode by POWER button
Main power off by the main power switch
Standby mode by RS-232C or LAN
Waiting mode by No Signal
●
Standby mode by abnormal temperature
Standby mode by SCHEDULE setting
Commands for setting of the GAMMA user data
*2
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
(A) (B)
RED GAMMA DATA TRANSFER
GREEN GAMMA DATA TRANSFER
BLUE GAMMA DATA TRANSFER
UGRW
UGGW
UGBW
W
aaxxxx xxxxcc
···
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
W
W
○ ○ ○
RED GAMMA DATA READ
GREEN GAMMA DATA READ
BLUE GAMMA DATA READ
USER DATA INITIALIZE
USER DATA SAVE
UGRR
UGGR
UGBR
UGRS
UGSV
W
W
W
W
W
1-16 xxxx xxxx
···
xxxx: User data of 32 pieces
(xxxx: 32 pieces)
xxxx: 0000-1023
1-16
1-16
0
0
Initialize the user data.
Save the user data in the monitor.
E
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
When the PN-ZB01 (optional) is attached, your monitor can
be connected to a LAN allowing you to control it from a PC on
Settings to connect to a LAN
the LAN.
Set the monitor’s IP address and subnet mask to match the
settings of your LAN.
These settings can be made on either the monitor or a PC
connected to the monitor.
The settings depend on the configuration of your LAN. Ask
your LAN administrator for details.
You can also configure the monitor to send e-mail notification
when it has a problem.
The connection requires a commercially available LAN cable
(UTP cable, Category 5, straight through).
Network (LAN)
■ To set on the monitor
Set RS-232C/LAN SELECT on the SETUP menu to LAN, and
then set the LAN SETUP options. (See page 11.)
After setting each item, select SET and press MENU
.
LAN terminal
Hub
DHCP CLIENT
If your LAN has a DHCP server and you wish to obtain an
address automatically, change this setting to ON.
To set the address manually, set this to OFF.
IP ADDRESS
If the DHCP CLIENT is set to OFF, specify an IP address.
LAN cable (commercially available, straight)
Press
or
to select items, and press
or
to
change the values.
SUBNET MASK
TIPS
If the DHCP CLIENT is set to OFF, specify the subnet mask.
• You must assign an IP address to the monitor by following
the procedures in “Settings to connect to a LAN”. (See the
description on the right.)
• Your PC must be installed with Internet Explorer (version 6.0
or later).
• To control the monitor via LAN, set RS-232C/LAN SELECT
to LAN. (See page 11.)
• You cannot use RS-232C and LAN control simultaneously.
Press
or
to select items, and press
or
to
change the values.
DEFAULT GATEWAY
If the DHCP CLIENT is set to OFF, specify the default
gateway.
If you are not using a gateway, specify “0.0.0.0”.
Press
or
to select items, and press
or
to
change the values.
RESET
Initializing personal information
• When the PN-ZB01 (optional) is attached, personal
information such as e-mail addresses can be registered in
the monitor. Before transferring or disposing of the monitor,
initialize all settings by selecting ALL RESET 1. (See
page 17.) Note that ALL RESET 2 will not initialize e-mail
addresses and other settings.
Resets the values of the LAN settings to the factory preset
values.
Select ON and then press MENU
.
E
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
7. Temporarily change the IP address and subnet mask.
To access the monitor as it is shipped from the factory, set
as follows.
■ To set from a PC
When the monitor is connected to a PC, LAN settings can be
configured via PC.
• IP Address: 192.168.150.3
• Subnet Mask: 255.255.255.0
• Default Gateway: (leave blank)
Set up process
(1) Connect your monitor to a PC
(2) Specify the PC’s IP address
(3) Configure the monitor’s LAN settings
(1) Connecting your monitor to a PC
Connect a commercially available crossover LAN cable
(UPT cable, Category 5) to the LAN port on the PC and this
monitor.
8. Click [OK] and then reboot the PC.
LAN terminal
TIPS
• This monitor is factory preset as shown below.
IP Address
Subnet Mask
: 192.168.150.2
: 255.255.255.0
PC
Default Gateway : 0.0.0.0
To LAN terminal
(3) Configuring the monitor’s LAN settings
Access the monitor using Internet Explorer.
LAN cable (commercially available, crossover)
Controlling the monitor
(2) Specifying the PC’s IP address
To configure the monitor’s LAN settings, you must temporarily
change the settings on the PC.
1. Turn the power ON to the monitor.
2. Set RS-232C/LAN SELECT on the SETUP menu to LAN.
This explanation is based on Windows XP.
1. Log on to the PC with an administrator account.
2. Click [Start], and then click “Control Panel”.
3. Click “Network and Internet Connections”, and then click
“Network Connections”.
PC operation
3. Launch Internet Explorer, in the “Address” box type
If you are using the classic display style, double-click on
“Network Connections”.
4. Right click on “Local Area Connection” and from the menu,
click “Properties”.
5. Click “Internet Protocol (TCP/IP)”, and then click
“Properties”.
You will be prompted to enter a user name and password.
4. Leave the user name and password boxes blank and click
[OK].
6. Make a note of the current IP address, subnet mask, and
default gateway settings.
Make sure you write this information now as you will
be changing the IP address, subnet mask, and default
gateway settings back to these settings afterwards.
E
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
5. Click on “LAN SETUP” under NETWORK.
6. Specify the “DHCP CLIENT”, “IP ADDRESS”,etc.
DHCP CLIENT
Controlling with a PC
■ Basic operation
You use Internet Explorer on a PC on the LAN to control the
monitor.
1. Launch Internet Explorer on the PC.
IP address followed by “/”, then press the Enter key.
When prompted to enter a user name and password, type
the user name and password that you specified in the
security settings (see page 33), and click [OK].
If you did not make any security settings, leave the spaces
blank and click on [OK].
3. You can check, control, and change the monitor’s status
and settings by clicking the menu items on the left side of
the screen.
• If you see an [Apply] button next to a setting, click it after
you change that setting.
If your LAN has a DHCP server and you wish to obtain an
address automatically, change this setting to “ON”.
To set the address manually, set this to “OFF”.
TIPS
• See pages 32 to 36 for details on each setting.
IP ADDRESS
• If you click [Refresh] before the screen finishes updating
the current display, the “Server Busy Error” will appear.
Wait for a moment before operating your monitor again.
• You cannot operate the monitor while it is warming up.
If the DHCP CLIENT is set to “OFF”, specify an IP
address.
SUBNET MASK
• If “DHCP CLIENT” is set to “ON”, press DISPLAY on the
remote control unit two times and then check the monitor’s
IP address.
If the DHCP CLIENT is set to “OFF”, specify the subnet
mask.
DEFAULT GATEWAY
If the DHCP CLIENT is set to “OFF”, specify the default
gateway.
If you are not using a default gateway, specify “0.0.0.0”.
7. When the setting is changed, click [Apply].
8. Check the message and click [OK].
9. Exit Internet Explorer.
10. Restore the PC’s IP address jotted in Step 6, “(2)
Specifying the PC’s IP address”.
11. Connect the monitor and the PC to the LAN.
Caution
• Wait 10 seconds after clicking [OK] before proceeding.
• When operating using the remote control unit or similar,
click [Refresh].
E
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
■ INFORMATION
■ ADJUSTMENT
Information about this monitor appears.
You can adjust these settings which are also available on the
monitor’s menu.
• SCREEN (See page 10.)
• PICTURE (See Page 10.)
• PICTURE (ADVANCED) (See Page 16.)
• AUDIO (See page 11.)
• SETUP (See page 11.)
• OPTION (See page 12.)
• SCHEDULE (See page 15.)
• ENLARGE (See page 12.)
• PIP/PbyP (See page 13.)
• FUNCTION (See page 17.)
■ CONTROL
You can control the operations corresponding to the buttons
POWER INPUT
(
SIZE ) on the remote control unit. (See page 5.)
TIPS
• In standby mode, Power ON is the operation available.
• MONITOR POWER turns the monitor power ON/
OFF regardless of the POWER BUTTON setting in the
FUNCTION menu.
E
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
■ NETWORK (LAN SETUP)
■ NETWORK (SECURITY)
This screen allows you to set the settings necessary when the
This screen allows you to specify the security-related settings.
monitor is connected to a LAN.
USER NAME / PASSWORD
DHCP CLIENT
Sets up a user name and password to restrict access to this
monitor.
After entering a user name and password, click [Apply].
If your LAN has a DHCP server and you wish to obtain an
address automatically, change this setting to “ON”.
To set the address manually, set this to “OFF”.
ACCEPT IP ADDRESS
IP ADDRESS
You can limit access to this monitor by registering IP
addresses of PCs that should have access.
To limit access, specify the option “From only specific IP
addresses”. Otherwise, to allow access from any PC, specify
“All IP Addresses”.
If the DHCP CLIENT is set to “OFF”, specify an IP address.
SUBNET MASK
If the DHCP CLIENT is set to “OFF”, specify the subnet
mask.
IP ADDRESS 1 to 3
DEFAULT GATEWAY
If “ACCEPT IP ADDRESS” is set to “From only specific IP
addresses”, enter the IP addresses that you want to allow.
If the DHCP CLIENT is set to “OFF”, specify the default
gateway.
If you are not using a default gateway, specify “0.0.0.0”.
TIPS
DNS SERVER
• The USER NAME and PASSWORD can be up to 8
alphanumeric characters or symbols.
Specify the DNS server address.
If you are not using a DNS server, specify “0.0.0.0”.
• To cancel the user name and/or password after it has been
set, make the box empty and click [Apply].
RESET
Clicking [Execute] returns all of the LAN SETUP settings
to the factory-preset values except for the DNS SERVER
setting.
E
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
■ NETWORK (GENERAL)
■ MAIL (ORIGINATOR)
This screen allows you to specify the general LAN settings.
This screen allows you to configure the e-mail sent periodically
or when the monitor has an error.
The settings depend on the configuration of your LAN. Ask
your LAN administrator for details.
MONITOR NAME
Specify a name for this monitor as it should appear on the
Internet Explorer screen.
SMTP SERVER
AUTO LOGOUT TIME
Specify the SMTP server address for sending e-mail.
* When using a domain name, make sure to specify the
DNS server as well. (See page 33.)
Specify the time (in minutes) to elapse before automatically
disconnecting this monitor from the network.
Specify in minutes from 1 to 65535. A value of ‘0’ will disable
this function.
ORIGINATOR E-MAIL ADDRESS
Specify the e-mail address for this monitor.
This address becomes the e-mail address of the originator.
DATA PORT
Specify the TCP port number to use for exchanging data with
the monitor.
ORIGINATOR NAME
Specify a value from 1025 to 65535.
Specify the name for the originator.
This name appears in the “Originator Name” field of the
e-mail.
SEARCH PORT
Specify the port number to use when searching for this
monitor.
AUTHENTICATION
Specify a value from 1025 to 65535.
Specify the authentication method to use when sending
e-mail.
INSTALLATION INFORMATION (NAME/LOCATION)
POP SERVER
Specify the information to display for this monitor in the
Internet Explorer window.
If the “AUTHENTICATION” method is “POP before SMTP”,
specify the POP server address.
TIPS
ACCOUNT NAME / PASSWORD
If the “AUTHENTICATION” method is “POP before SMTP”,
specify the account name and password to connect to the
POP server.
• The MONITOR NAME can be up to 16 alphanumeric
characters or symbols.
• Enter up to 50 characters in the NAME field in the
INSTALLATION INFORMATION.
• Enter up to 100 characters in the LOCATION field in the
INSTALLATION INFORMATION.
TIPS
• You can enter up to 64 alphanumeric characters or symbols
for the ORIGINATOR E-MAIL ADDRESS, ORIGINATOR
NAME, ACCOUNT NAME, and PASSWORD.
• The SMTP SERVER and POP SERVER can be up to 64
characters.
The following characters can be used: a-z, A-Z, 0-9, - , .
E
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
■ MAIL (RECIPIENT)
■ MAIL (PERIODICAL)
This screen allows you to specify the recipients of the e-mail
When PERIODICAL for CONDITION of MAIL (RECIPIENT) is
sent periodically or when the monitor has an error.
checked, set the date and time to send the mail.
RECIPIENT E-MAIL ADDRESSES
DAY OF THE WEEK
Specify the e-mail addresses to send error notification e-mail
to.
Specify the day of the week to send the periodical mails.
TIME
CONDITION
Specify the time of the day to send the periodical mails.
Specify the conditions to send mails.
When you check PERIODICAL, specify the date and time to
send the mails in the PERIODICAL setting.
Caution
• Do not turn off the main power when you set to send the
periodical mails.
CONFIRMATION
Sends test e-mail.
This allows you to confirm that the e-mail settings are
configured properly.
• Specify the correct date and time. (See page 12.)
If the date and time settings are incorrect, the periodical
mail is not sent properly.
• Regularly confirm that the specified date and time is
correct.
Attach the log file to a TEMPERATURE/HARDWARE error
e-mail
• When LOW POWER is selected for STANDBY MODE,
periodical mails will not be sent in standby mode.
When this option is checked, a log is added to the mail which
notifies a temperature or status error.
TIPS
• The RECIPIENT E-MAIL ADDRESSES can be up to 64
alphanumeric characters or symbols.
E
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor with a PC (LAN)
Caution
■ SNMP
You can configure settings related to SNMP.
• After you set SNMP, click [Restart the monitor immediately.]
or turn off the monitor and then turn it on again with the
main power switch. When the monitor restarts, wait about
30 seconds and then start the next operation.
TIPS
• Depending on the SNMP settings, a short delay may occur
before the SNMP is usable. (About 2 minutes)
• Up to 16 alphanumeric letters and symbols can be used for
the community name, user name and password.
■ SERVICE & SUPPORT
(URL INFORMATION)
You can display a specific URL in the URL INFORMATION
field on the INFORMATION screen when an error occurs in
the monitor. (See page 32.)
URL INFORMATION
Enter the URL to display on the INFORMATION screen when
an error occurs on the monitor.
Up to 64 alphanumeric characters or symbols can be used.
SNMP SETTING
Set whether to enable or disable SNMP.
VERSION
CONDITION
Set the version of the SNMP to be supported.
COMMUNITY NAME 1 to 3
Set the name of the community required for the access.
User 1 to 3
Specify the condition to display the URL.
CONFIRMATION
The home page of the specified URL is displayed.
You can check whether the URL you entered is correct.
Set the user name, password, authentication method and
other options required for access.
TIPS
TRAP SETTING
• It is also possible to specify the message text, such as the
name of a contact or a telephone number, to be displayed
instead of the linked URL.
Set whether to enable or disable the trap function.
When this function is enabled, a trap will be sent when the
monitor is turned on.
TRAP WHEN AUTHENTICATION FAILS
Set whether the trap function sends a notification when
authentication fails.
TRAP ADDRESS & PORT NO.
Set the destination address and port number of the
notification sent by the trap function.
E
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
If you are experiencing any problem with your display, before
calling for service, please review the following troubleshooting
tips.
The video from the PC RGB input terminals or AV
component input terminals does not appear properly.
• Is the setting for BNC of INPUT SELECT on the OPTION
menu correct? (See pagae 12.)
• Is the input signal compatible with this monitor? (See
Specifications.)
There is no picture or sound.
• Is the power cord disconnected?
• Is the main power switch off?
• Is the monitor in standby mode (the power LED illuminating
in orange)?
Control buttons do not work.
There is no picture.
• Make sure correct input mode is selected. (See page 5.)
• If any external equipment is connected, make sure the
equipment is operating (playing back).
• Load noises from outside may be interfering with normal
operation. Turn off the power and turn it on after waiting at
least 5 seconds, and then check the operation.
Remote control does not work.
• Are the batteries inserted with polarity (+,-) aligned? (See
Operation manual.)
• Are the batteries exhausted?
• Point the remote control unit toward the monitor’s remote
control sensor.
The input mode changes automatically.
• When the AUTO INPUT CHANGE is ON and no signal
is present in a selected input mode, the AUTO INPUT
CHANGE automatically changes the selected mode to a
mode where a video signal is present.
The input mode may change in the following cases:
- When a computer is in standby mode.
• Is the menu display hidden or is operation disabled? (See
page 17.)
- When video play is stopped with a playback device.
Sound from left and right speakers is reversed.
Sound is heard from only one side.
Power LED flashes red.
“STATUS [xxxx]” appears in the corner of the screen.
• Hardware has a problem. Turn off the monitor and request
repair from your SHARP dealer.
• Are audio cables connected properly?
• Make sure audio cables for external speakers are
connected properly: left and right cables may be reversed
or one of the two cables may not be connected.
• Check the setting of BALANCE for AUDIO menu. (See
page 11.)
(When STATUS ALERT is set to OSD & LED. This varies
depending on the setting.)
When “AUTO DIMMING” is displayed.
• When the internal temperature of the monitor rises
excessively, the brightness of the backlight automatically
decreases in order to prevent a further temperature rise. If
There is a picture but no sound.
• Is the sound muted?
• Make sure the volume is not set to minimum.
• Are audio cables connected properly?
• Is the setting of AUDIO SELECT on the OPTION menu
correct? (See page 12.)
you attempt to use
the monitor is in this state, “AUTO DIMMING” is displayed
and you cannot change the brightness.
• Remove the cause of the excessive temperature rise.
to adjust the brightness while
• Is the setting of SPEAKER SELECT on the SETUP menu
correct?
The monitor makes a cracking sound.
• You may occasionally hear a cracking sound from the
monitor. This happens when the cabinet slightly expands
and contracts according to change in temperature. This
does not affect the monitor’s performance.
Unstable video.
• The signal may be incompatible.
• Try the automatic screen adjustment when the PC D-sub
input terminal or PC RGB input terminals are used.
The Power LED is flashing in red and green alternately.
When “TEMPERATURE” is displayed in the corner of the
screen.
The video from the PC/AV HDMI input terminal does not
appear properly.
• Is the setting for HDMI of INPUT SELECT on the OPTION
menu correct? (See page 12.)
• Is the HDMI cable HDMI standard compliant? The monitor
will not work with cables that are not standard compliant.
• Is the input signal compatible with this monitor? (See
Specifications.)
• When the internal temperature of the monitor rises
excessively, the brightness of the backlight decreases
automatically in order to prevent high-temperature-
related problems. When this occurs, “TEMPERATURE” is
displayed on the screen and the Power LED flashes red
and green alternately. (When TEMPERATURE ALERT is
set to OSD & LED. This varies depending on the setting.)
• If the internal temperature rises further, the monitor
automatically enters standby mode. (The Power LED
continues flashing red and green alternately.)
• Remove the cause of the excessive temperature rise.
- If the monitor enters standby mode due to a rise in
temperature, to return to normal display, turn the power
switch off and then back on again. The monitor, however,
will enter standby mode again if the cause of the
temperature rise is not eliminated.
The video from the PC/AV DVI-D input terminal does not
appear properly.
• Is the setting for DVI of INPUT SELECT on the OPTION
menu correct? (See page 12.)
• Is the input signal compatible with this monitor? (See
Specifications.)
• Turn off the power to the connected equipment and then
turn the power on again.
• If the monitors are connected in a daisy chain, turn off the
power to all the monitors connected in a daisy chain and
then turn the power on again.
- Check whether the monitor is placed at a location where
a quick rise in temperature is likely. Internal temperature
rises quickly if the vents on the monitor are blocked.
- Internal temperature rises quickly if dust accumulates
inside the monitor or around the vents. Remove dust if
possible. Ask Sharp dealer about removing internal dust.
E
37
Download from Www.Somanuals.com. All Manuals Search And Download.
PN-E601E521 G EN09L(2)
Download from Www.Somanuals.com. All Manuals Search And Download.
|