ROOM AIR CONDITIONER  
INSTALLATION AND OPERATION  
MANUAL  
CONTENTS  
PAGE  
FOR YOUR PROTECTION.................... 2  
CONSUMER LIMITED WARRANTY ..... 3  
INSTALLATION INSTRUCTIONS  
• CHECK WINDOW AREA ........................ 4  
• LOCATlON .............................................. 4  
• ITEMS PACKED WITH THlS UNIT......... 5  
• SUGGESTED TOOLS ............................ 5  
• INSTALLATION....................................... 5  
PRECAUTIONS  
CAUTION FOR USE ............................ 8  
• GROUNDING INSTRUCTIONS ........... 8  
• NOTES ON OPERATION .................... 9  
• ENERGY EFFICIENCY TIPS............... 9  
HOW TO OPERATE  
• PARTS NAMES ...................................10  
COOLING OPERATION ......................11  
TO CHANGE TEMPERATURE SETTING.......... 11  
• TO CHANGE FAN SPEED ..................12  
• FAN ONLY OPERATION .....................12  
• ENERGY SAVER .................................13  
TO CHANGE AIR FLOW DIRECTION ....... 13  
• EXHAUST ............................................13  
• ON TIMER OPERATION .....................14  
• OFF TIMER OPERATION....................15  
• USING THE REMOTE CONTROL.......16  
This INSTALLATION AND OPERATION  
MANUAL explains the proper use of your new  
Sharp Air Conditioner. Read these instructions  
carefully before installing or operating your air  
conditioner. The INSTALLATION AND OP-  
ERATION MANUAL should be kept in a safe  
place for handy reference.  
CLEANING AND MAINTENANCE ........ 18  
BEFORE CALLING FOR SERVlCE...... 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONSUMER LIMITED WARRANTY  
CONSUMER LIMITED WARRANTY  
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"),  
when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option,  
either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to  
the purchaser for parts or labor for the period(s) set forth below.  
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor  
to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse,  
abnormal service or handling, or which has been altered or modified in design or construction.  
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof  
of purchase to the servicer.  
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL  
IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED  
TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long  
an implied warranty lasts, so the above limitation may not apply to you.  
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described  
herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.  
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive  
remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute  
complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute  
full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable,  
or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed  
by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential  
economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above  
exclusion may not apply to you.  
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM  
STATE TO STATE.  
AF-R100CX, AF-R120CX or AF-R140CX Room Air Conditioner. Be  
sure to have this information available when you need service for your  
Product.  
Your Product Model Number & Description:  
Warranty Period for this Product:  
One (1) year parts and labor from date of purchase. The warranty  
period continues for a total of five (5) years from date of purchase for  
the Sealed Cooling System parts; labor and service are not provided  
free of charge for this additional period.  
Additional Item(s) Excluded From  
Warranty Coverage (If any):  
Appearance items of the Product, knobs, filter, or accessories, mounting  
kit, seals, or any printed materials.  
Where to Obtain Service:  
From a Sharp Authorized Servicer located in the United States. To find the  
location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at  
1-800-BE-SHARP.  
What to Do to Obtain Service:  
Contact your Sharp Authorized Servicer to obtain in-home service for this  
Product. The Servicer will come to your home, and if it is necessary to  
remove the Product, the Servicer will reinstall it. Be sure to have Proof of  
Purchase available.  
OR CALL 1-800-BE-SHARP.  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah, New Jersey 07430-2135  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Before beginning installation, read these instructions carefully.  
Use the enclosed MOUNTING KIT for proper installation.  
CHECK WINDOW AREA  
The mounting kit is designed for wooden sill double or single hung sash-type windows.  
Minimum opening  
Mounting kit fully closed  
Mounting kit fully opened  
38 19/ 32 "(980mm)  
(Without mounting kit)  
1
5
22 /32 "(560mm)  
27 /32"(690mm)  
Window opening from stool  
to lower sash bottom must  
be 16 1 /32"(407mm) or more.  
Lower sash bottom  
Stool  
LOCATION  
The air conditioner should be installed on a firm foundation to minimize noise and vibration.  
For safe installation, repairs, replacement and secure positioning, make sure foundation is  
solid and level.  
The room air conditioner must be installed in an area within reach of a properly rated  
grounded outlet.  
Use of extension cords of any kind is not recommended.  
Never place any obstacles around air inlet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
ITEMS PACKED WITH THIS UNIT  
1
Q'ty  
1
No.  
Accessories  
2
1
2
3
Right closure assembly  
Left closure assembly  
Window sash foam seal  
1
1
3
Window sash foam seal  
(adhesive type)  
4
5
1
4
Bottom gasket  
1
8
5
6
Screws(L=1", 25.4mm)  
Screws(L=13/32", 10mm)  
Remote control  
6
7
7
8
6
1
6
8
9
Battery  
2
1
8
10  
Remote control hook  
10  
9
2
SUGGESTED TOOLS  
1. Screw driver (medium size Phillips)  
2. Tape measure or ruler  
3. Knife or scissors  
INSTALLATION  
These models can also be installed through the wall with the optional through the wall mounting  
kit, model AZ-80WK. To order this kit either contact your dealer or call 1-800-BE-SHARP.  
The wall opening dimensions for through the wall installation are:  
1
3
25" (635mm) (W) 17 / 4 " (438mm) to 17 / 4 " (451mm) (H) 4" (102mm) minimum (D).  
Complete instructions are included with the wall mounting kit.  
WARNING Make sure the unit is turned off and unplugged before working.  
:
(1) Cut the window sash foam seal (adhesive type)  
to the proper length and attach it to the  
underside of the window sash.  
1
window sash foam seal  
(adhesive type)  
(2) Attach the bottom gasket to the outer side of the  
window sill.  
bottom gasket  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Unscrew the 2 screws at the corners of  
the front panel. Keep them as they will  
be used later.  
Remove the front panel by pulling the  
front panel at the lower corners towards  
you about an inch.  
(1)  
(2)  
2
3
Horizontal  
Louver  
Front panel  
Next lift it up and pull it towards you.  
Front  
panel  
Exhaust Lever  
CAUTION:  
Take care not to damage the exhaust  
lever when removing the front panel.  
Unscrew the 6 stopper screws of the  
cabinet. Keep the 4 screws from the  
top and front , as they will be used later.  
Slide the chassis out from the cabinet  
by pulling on the hand hold located at  
the bottom center of the chassis.  
(1)  
(2)  
CAUTION:  
Do not remove any material (ex.  
styrofoam, etc.) from inside the unit.  
Closure assembly  
Insert the right closure assembly and the  
left closure assembly into the top angle  
and the bottom channels.  
4
5
Secure the right and left closure to the  
cabinet with 6 of the provided screws.  
(L=13 /32", 10 mm)  
Open the window sash and place the  
cabinet on the sill.  
Close the window sash securely behind  
the top angle.  
If there is space between the bottom  
channel and the sill, fill the gap with a  
thin board or other hard filler.  
WARNING  
Cabinet  
At this step, make sure the cabinet is in-  
clined approximately 1 cm (3/8) to the  
back.  
If the cabinet is not properly inclined, the  
water collected in the bottom tray during  
operation will not drain properly and may  
flow into the room where the air conditioner  
is installed.  
sill  
incline backwards about 1cm (3/8")  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Closure assembly  
(Left)  
Insert the closure assemblies on both  
sides into the rails of the jamb.  
6
7
Indoor  
side  
Jamb  
(Left)  
Closure assembly  
(Left)  
1/2 inch (13mm)  
Sill  
Stool  
Top angle  
Secure the cabinet to the window  
stool with 3 screws (L=1", 25.4 mm),  
working from the inside of the cabinet.  
(1)  
(2)  
Secure the top angle and the closure  
assemblies to the window sash with 3  
screws (L=1", 25.4 mm).  
(3)  
Secure the closure assemblies to the  
sill with 2 screws (L=1", 25.4 mm).  
(1)  
Slide the chassis back into the cabinet.  
8
9
(2) Replace the 4 screws removed in  
step 3 to the top and side of the cabinet .  
(1)  
Replace the front panel. Slip the ex-  
haust lever through the opening  
between the horizontal louver and the  
front panel then, hook the cabinet top.  
Horizontal  
Louver  
CAUTION:  
Take care not to damage the exhaust  
lever with the front panel.  
Front  
Panel  
Exhaust Lever  
(2)  
Screw the front cabinet on at the bottom  
corners with 2 screws removed in step 2.  
Window sash foam seal  
Cut the window sash foam seal to the  
proper length and seal the opening be-  
tween the top of the inside window sash  
and the outside window sash.  
10  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRECAUTIONS  
CAUTION FOR USE  
IMPORTANT: Points to keep in mind when using your air conditioner.  
Install the air conditioner by following the installation instructions given in the  
previous section of this manual.  
Make sure the unit is the correct capacity for the area you want to cool.  
Do not modify any part of this product.  
Do not insert objects into any part of the unit.  
Push the AC power plug securely into the receptacle and make sure it is not loose.  
Use power circuit with a proper voltage rating.  
Use a three-pronged grounded electrical outlet rated 125V,  
60Hz, 15 amp or more, AC only as shown on right.  
Use of an improper voltage rating power circuit can result in  
damage to the unit and possibly fire.  
Two-Pole, 3-wire Grounding  
Receptacle 15 Amps. 125V.  
Always use a fuse with the proper amp rating.  
Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse.  
Use of extension cords of any kind is not recommended.  
If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire  
grounding type appliance extension cord rated 125 Volts, 15 amp or more.  
Ventilate the room periodically during use, especially if using gas appliances.  
GROUNDING INSTRUCTIONS  
WARNING: Improper use of the grounding plug can result in the risk of electric  
shock.  
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the  
risk of electric shock by providing an escape wire for the electric current.  
This appliance is equipped with a cord having a grounding wire with a grounding plug.  
The plug must be plugged into an outlet that is properly installed and grounded.  
WARNING: Do not under any circumstances cut or remove the round grounding prong  
from this plug.  
If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-blade  
grounding plug, and a 3-slot receptacle that will accept the plug on the appliance.  
The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more.  
Consult a qualified electrician or serviceman if the grounding instructions are not completely  
understood, or if doubt exists as to whether the appliance is properly grounded.  
If a grounding adapter is used, make sure the receptacle box is fully grounded.  
Grounding  
adapter  
Grounded  
receptacle box  
3-Pronged receptacle  
Grounded  
receptacle box  
Grounding  
wire  
3-Pronged plug  
Screw  
Tab for grounding screw  
Grounding prong  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRECAUTIONS  
NOTES ON OPERATION  
Allow 3 minutes for the compressor to restart cooling.  
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to  
restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for  
protection.  
If a power failure occurs during use, allow 3 minutes before restarting the unit.  
After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be  
sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three  
minutes, a protective device in the unit may cause the compressor to shut off. This protective device will  
prevent cooling for about 5 minutes.  
Memories of previous settings will be canceled and the unit will return to each initial setting.  
• Dehumidifying function  
The air conditioner removes moisture from the air in your room.  
Cooling operation under low temperatures: Is your unit freezing up?  
The unit operates on inside and outside temperatures. Freezing can occur when the temperature is set  
close to 64°F and when there are low outside temperatures, especially during the night hours. At these  
conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher  
temperature will prevent it from freezing.  
ENERGY EFFICIENCY TIPS  
Setting the proper temperature.  
For optimum energy efficiency, keep the difference between the inside and outside temperature within  
10°F(5°C). Do not keep the temperature setting any lower than is necessary for you to feel comfortable.  
Generally, 78°F to 80°F(26°C to 27°C) is a comfortable summer indoor temperature.  
When you turn the unit on, do not set the temperature higher than the room temperature at start up as  
this will not allow the compressor to cycle and maintain a comfortable room temperature.  
Avoid direct sunlight.  
Close blinds, drapes or shades to keep out direct sunlight during cooling operation.  
Keep the filter clean.  
Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air  
conditioner work harder and less efficiently. See page 18 on how to clean the filter.  
Turn off unnecessary light.  
Your air conditioner must remove the heat produced by your lights or other heat-producing appliances.  
Turn off lights or appliances that are not in use.  
Install your air conditioner in a shady location.  
Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.  
Don't let cool air escape.  
Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed  
air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.  
Turn off air conditioner when no one is home.  
Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION INSTRUCTIONS  
PARTS NAMES  
UNIT  
5
6
4
7
8
9
3
10  
2
1
12  
11  
1
2
3
Front panel  
Air inlet (Indoor side)  
Louvers  
Air outlet (Indoor side)  
Exhaust lever  
Control panel  
Cabinet  
7
8
Air outlet (Outdoor side)  
Air inlet (Outdoor side)  
Filter (Pull the filter handle to the right to remove.)  
Filter handle  
9
10  
11  
12  
4
5
6
Power cord  
CONTROL PANEL  
1
2
3
HIGH COOL  
MED COOL  
LOW COOL  
FAN ONLY  
F
hr  
TEMP  
TIMER  
ON/OFF  
ENERGY  
SAVER  
POWER  
ON/OFF  
SELECTOR  
4
5
6
7
8
9
10 11  
1
7
8
SELECTOR indicator  
Receiver window for remote control  
signal  
TEMPERATURE setting pad  
----Lower temp.  
2
----Raise temp.  
Display  
3
4
5
6
ENERGY SAVER pad  
ENERGY SAVER indicator  
POWER ON/OFF pad  
POWER indicator  
SELECTOR pad  
TIMER ON/OFF pad  
TIMER indicator  
9
10  
11  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE
COOLING OPERATION  
Display / Indicator  
Procedure  
Pad  
Touch POWER ON/OFF  
pad.  
F
1
2
POWER  
hr  
ON/OFF  
The unit is preset at 74°F and  
HIGH COOL. This will show  
in the display when the power  
is first turned on.  
POWER indicator and  
SELECTOR indicator  
(HIGH COOL) will light.  
To turn off the unit, touch  
POWER ON/OFF pad again.  
POWER indicator and  
SELECTOR indicator will  
go off.  
POWER  
ON/OFF  
TO CHANGE TEMPERATURE SETTING  
Display / Indicator  
Procedure  
Pad  
During cooling operation  
TEMP  
F
Touch the TEMPERATURE  
setting pad to adjust the tem-  
perature setting.  
hr  
It can be set within the range of  
64°F to 86°F.  
---Lower temp.  
---Raise temp.  
Display will change as you  
touch the pad.  
The latest temperature setting will be memorized and will appear on the display the next time  
the unit is turned on.  
NOTE:  
In cases of power outages or when the unit is disconnected; when the power is restored or the  
unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH  
COOL. The unit will not automatically turn back on. The user must touch POWER ON/OFF to  
resume operation.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
TO CHANGE FAN SPEED  
Display / Indicator  
Procedure  
Pad  
During operation  
SELECTOR indicator will  
light in order as you touch.  
Touch SELECTOR pad  
and select the desired fan  
speed.  
SELECTOR  
HIGH COOL  
MED COOL  
LOW COOL  
FAN ONLY  
NOTES ON FAN SPEED  
Fan and cooling at maximum performance.  
HIGH COOL  
Unit is preset to HIGH COOL when first turned on after unit is plugged in.  
Fan operates at medium speed; cooling power at medium.  
MED COOL  
LOW COOL  
Cooling for sleeping comfort with low fan speed.  
FAN ONLY OPERATION  
This setting can be used to circulate air whenever cooling is not desired.  
The fan will operate at medium speed.  
Display / Indicator  
Procedure  
Pad  
SELECTOR indicator FAN  
ONLY will light, and the tem-  
perature display will go off.  
After 5 seconds, the com-  
pressor will stop and the unit  
will operate in FAN ONLY  
mode.  
During operation  
Touch SELECTOR pad  
and select FAN ONLY.  
SELECTOR  
When the unit is turned off, the last fan speed will be stored in memory.  
The next time the air conditioner is used, the memorized fan speed will start automatically.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
ENERGY SAVER  
During normal operation, the thermostat automatically controls cooling and the fan runs  
continuously. When the ENERGY SAVER is selected, the thermostat automatically  
controls cooling and the fan automatically stops when the compressor is not operating.  
(Fan will stop 30 seconds after the compressor stops.Even after the fan stops, the fan will  
rotate for 2 minutes, every maximum 20 minutes, to detect room temperature.)  
Display / Indicator  
Procedure  
Pad  
During cooling operation  
ENERGY SAVER indicator  
will light.  
ENERGY  
SAVER  
Touch ENERGY  
SAVER pad.  
1
ENERGY SAVER indicator  
will go off.  
To cancel, touch  
ENERGY SAVER  
pad again.  
2
ENERGY  
SAVER  
NOTE: ENERGY SAVER cannot be set during FAN ONLY mode operation.  
TO CHANGE AIR FLOW DIRECTION  
Adjust the louvers to change the direction  
of air flow for uniform and efficient cooling  
of the room.  
Horizontal louvers  
Adjusts UP/DOWN air flow  
Vertical louvers  
Adjusts LEFT/RIGHT air flow  
EXHAUST  
If air in your room is stale, set the  
EXHAUST lever to the OPEN position.  
This will exhaust stale air to the outside.  
The EXHAUST lever should normally  
be kept in the CLOSED position during  
cooling for maximum efficiency.  
EXHAUST Lever  
CLOSED  
OPEN  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
ON TIMER OPERATION  
This unit has a built-in timer that can be programmed to start the unit up to 12 hours in  
advance.  
You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in  
advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the  
start time.  
Set the timer when the unit is not operating.  
The unit will start automatically according to your setting.  
Display / Indicator  
Procedure  
Pad  
SELECTOR indicator and  
TIMER indicator will light.  
Touch the TIMER ON/  
TIMER  
ON/OFF  
1OFF pad to set the  
delayed start time.  
If you wish to start the op-  
eration 6 hours and 30 min-  
utes later, set the delay time  
as shown below.  
The unit is preset to 0.5  
hours (30 minutes).  
The timer will be set, 5  
seconds after the  
TIMER ON/OFF pad is  
touched for the last  
time.  
F
hr  
The time display will count  
down the remaining time.  
The unit will start when the  
set time expires.  
The temperature setting will  
be displayed.  
The time setting will change as you touch the pad.  
The display will change as follows;  
Preset(0.5h)  
Previous setting  
1.0h  
0.5h  
1.5h  
10h  
CL(cancel)  
12h  
11h  
To cancel the timer setting, touch the TIMER ON/OFF pad again after the timer is  
set or, press the TIMER ON/OFF pad until CL(cancel) appears on the display.  
After setting the ON TIMER, change the temperature and fan speed settings as shown on pages  
11 and 12. When the temperature is set in the timer mode, the temperature will show in the  
display for 5 seconds and then return to the time display.  
The last setting used will be memorized and will appear on the display the next time you operate  
the unit with the TIMER function.  
If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled  
and will not resume even after power is reinstated. The unit will not automatically start.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
OFF TIMER OPERATION  
This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours  
in advance.  
You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in  
advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the  
stop time.  
Set the timer when the unit is operating.  
The unit will stop automatically according to your setting.  
Display / Indicator  
Procedure  
Pad  
Touch the TIMER ON/  
SELECTOR indicator and  
TIMER  
ON/OFF  
1 OFF pad to set the  
TIMER indicator will light.  
delayed stop time.  
If you wish to stop the op-  
eration 10 hours later, set  
the delay time as shown  
below.  
The unit is preset to 0.5  
hours (30 minutes).  
The timer will be set, 5  
seconds after the  
TIMER ON/OFF pad is  
touched for the last  
time.  
F
hr  
The time display will count  
down the remaining time.  
The unit will stop when the  
set time expires.  
All indicators and displays will  
go out.  
The time setting will change as you touch the pad.  
The display will change as follows;  
Preset(0.5h)  
Previous setting  
1.0h  
0.5h  
1.5h  
10h  
CL(cancel)  
12h  
11h  
To cancel the timer setting, touch the TIMER ON/OFF pad again after the timer is  
set or, press the TIMER ON/OFF pad until CL(cancel) appears on the display.  
After setting the OFF TIMER, change the temperature and fan speed settings as shown on  
pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in  
the display for 5 seconds and then return to the time display.  
The last setting used will be memorized and will appear on the display the next time you operate  
the unit with the TIMER function.  
If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled  
and will not resume even after power is reinstated. The unit will not automatically start.  
OFF TIMER OPERATION can also be set with the REMOTE CONTROL.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
USING THE REMOTE CONTROL  
INSTALLING BATTERIES  
Use two size-AAA (R03) batteries.  
1
Remove the battery compartment cover.  
Insert the batteries in the compartment,  
2 making sure the  
and  
polarities  
are properly aligned.  
Battery compart-  
ment cover  
Replace the cover.  
3
NOTES:  
The battery life is approximately one year with normal use.  
When you replace the batteries, always use two new ones of the same type.  
If the remote control does not operate normally after replacing the batteries, take out the  
batteries and replace them again after 30 seconds.  
If you will not be using the unit for a long time, remove the batteries from the remote control.  
ATTACHING THE REMOTE CONTROL HOOK  
Cabinet  
Remove the backing from the remote control hook.  
Attach the hook onto the left side of the unit's  
cabinet.  
Front Panel  
To prevent loss, hook the remote control on the  
cabinet when not in use.  
Remote control hook  
HOW TO USE THE REMOTE CONTROL  
Point the remote control towards the unit's re-  
ceiver window and press the desired button. A  
beep will sound when the unit receives the signal.  
Make sure no objects, such as curtains, block the  
receiver window.  
The remote control operates from up to 20 feet (6  
meters) away.  
The beep will also sound when each pad on the  
control panel is touched.  
CAUTION:  
Do not expose the receiver window to direct sunlight. This can adversely affect its operation. In  
such case, close the curtains to block the sunlight.  
Use of a fluorescent lamp in the same room may interfere with the transmission of the signal.  
The unit may be affected by signals emitted from the remote control of a television, VCR or other  
equipment used in the same room.  
Do not leave the remote control exposed to direct sunlight or near a heater. Protect the remote  
control from moisture and shock which can discolor or damage it.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
OPERATING WITH THE REMOTE CONTROL  
TRANSMITTER  
POWER  
ON/OFF  
POWER ON / OFF button  
Push to start or stop the operation.  
TEMP.  
TEMPERATURE setting button  
TEMP.  
TEMP.  
---Raise temp. setting 1°F at a time.  
---Lower temp. setting 1°F at a time.  
TEMP.  
SELECTOR  
SET TIMER/OFF  
HIGH COOL  
MED COOL  
LOW COOL  
FAN ONLY  
SELECTOR button  
Push to change fan speed, or to select  
fan only mode.  
Fan speed selections are shown to the  
right.  
SET TIMER / OFF button  
Push to set delay "OFF" timer during operation.  
The time setting will change as you push the button. The  
display will change as follows;  
Preset(0.5h)  
Previous setting  
1.0h  
0.5h  
1.5h  
10h  
CL(cancel)  
12h  
11h  
The last OFF time setting is memorized by the unit and  
will appear on the display when the button is pushed.  
The timer will be set, 5 seconds after the SET TIMER /  
OFF button is pushed for the last time.  
NOTE:  
If you wish to cancel the timer, push the SET TIMER /  
OFF button again after the time is set or, push the SET  
TIMER / OFF button until CL (cancel) appears on the  
display. A double beep will sound when the timer is  
cancelled.  
The "ON" TIMER cannot be set  
with the remote control.  
It can only be activated by the  
TIMER ON/OFF pad on the unit's  
control panel ( See page 14 ).  
To Change the Temperature Setting When the ON / OFF Timer Is In Use  
1.  
Push a TEMPERATURE setting button.  
The current set temperature will be recalled on the unit's display.  
Use the TEMPERATURE setting buttons to set the new temperature.  
The new set temperature will show on the display for 5 seconds and return to the  
time display.  
2.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANINGANDMAINTENANCE  
CLEANING THE FILTER  
If the filter is clogged with dust, the amount of air flow will  
be reduced, resulting in poor cooling performance. The  
filter should be cleaned every10 days. At the beginning  
of every cooling season or after a long period of  
inactivity, clean the filter before starting the unit.  
REMOVE THE FILTER  
1Gently pull the filter handle to the right and slide the  
filter out from the unit.  
CLEAN THE FILTER  
2To remove dust from the filter, use a vacuum cleaner  
or wash it in clean water.  
If the filter is very dirty, wash it with detergent and  
rinse carefully with clean water. Dry the filter with  
a soft cloth.  
Do not expose the filter to heat or dry it in direct  
sunlight.  
RE-INSTALL THE FILTER  
3Align the filter behind the front panel.  
Grasp the filter handle and gently push the filter back  
into place.  
Never operate the unit without installing the filter. It  
may result in serious damage to the unit.  
CLEANING OF THE FRONT PANEL AND CABINET  
To clean the front panel and cabinet, wipe with a soft, dry cloth or with a cloth moistened with a  
mild soap. Rinse carefully by wiping with a damp cloth and dry completely.  
Avoid splashing the unit with water. Excess water can damage electrical insulation and result in  
danger.  
Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage to the  
unit, do not use hot water (120°F(50°C) or more) when cleaning.  
OILING OF THE COMPRESSOR AND FAN MOTOR IS  
UNNECESSARY  
The compressor is permanently lubricated and is hermetically sealed. The fan motor is lifetime  
sealed and does not require oiling.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE CALLING FOR SERVlCE  
IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK  
THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE.  
AIR CONDITIONER DOES NOT OPERATE AT ALL  
Is the unit plugged in or is the plug loose?  
Is the fuse blown or the circuit breaker tripped?  
Did you restart the unit within 3 minutes after a power failure? If the power was off for less than 3  
minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the  
compressor to shut off, preventing cooling for about 5 minutes.  
AIR CONDITIONER DOES NOT PROPERLY COOL  
Is the SELECTOR set to fan only mode?  
Cooling will not take place in the fan only mode. Change the SELECTOR setting.  
Is the filter clogged with dust?  
A dirty filter can cause the cooling coils to freeze. If this happens, clean the filter and replace. Run  
the air conditioner on the fan only setting until all ice dissipates.  
Is the temperature set properly?  
If your room is too warm, adjust the temperature setting lower.  
If your room is too cool, adjust the temperature setting higher.  
Is the EXHAUST lever in the OPEN position.?  
The lever should be in the CLOSED position during cooling.  
Is the window exposed to direct sunlight?  
Close curtains or blinds to minimize solar energy heating the room.  
Are the windows or doors open?  
Close all windows and doors for maximum cooling.  
TIMER DOES NOT WORK PROPERLY  
If a power failure occurs while the ON or OFF TIMER is set, the TIMER setting will be cancelled and  
will not resume even after the power is reinstated. This is the normal operation for this unit.  
NOTE: WATER IN BOTTOM OF TRAY  
Water will collect in the bottom tray of the unit. This is normal. Water condenses on the evaporator  
coil at the front of the unit and is channeled to the rear where it is picked up by the condenser fan.  
The water is blown onto the condenser coil fins and this creates a "splashing" noise which is normal.  
If excess water builds up in this tray it will drain outside through a grooved channel in the tray.  
SOUNDS  
The operating sound may seem rather loud for 2 to 3 minutes when the unit is first turned on. This  
is the sound of the compressor's start-up and is normal.  
A soft, swishing noise can be heard immediately after the unit is turned on or off, and also during  
operation. This is the sound of the refrigerant flowing inside the unit.  
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL  
Check the remote control batteries. Replace if necessary.  
Try to send the signal again with the remote control pointed directly at the unit's receiver window.  
Check whether the remote control batteries are installed with the polarities properly aligned.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah, New Jersey 07430-2135  
SHARP CORPORATION  
Osaka, Japan  
Printed in Thailand  
TINSEA297JBRZ 01LO  
TL  
1
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Laptop PC MM1 User Manual
Sony Ericsson Cell Phone Z710c User Manual
Sony Headphones Qualia 010 User Manual
Sony Projector VPL VW85 User Manual
Specialized Cyclometer Comp User Manual
Subaru Robin Power Products Portable Generator RGX180 User Manual
Sunrise Medical Wheelchair S 11 User Manual
SUPER MICRO Computer Computer Hardware H8QG6+ F User Manual
Sylvania Clock Radio SKCR2601 User Manual
Tanaka Automobile Parts PF 4000 User Manual