Sennheiser Satellite Radio SKP 100 User Manual

SKP 100  
Instruction Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Contents  
Important safety instructions .......................................................................... 2  
The SKP 100 G3 plug-on transmitter .............................................................. 3  
Areas of application ........................................................................................ 3  
The frequency bank system .......................................................................... 3  
Delivery includes .................................................................................................. 4  
Product overview ................................................................................................. 5  
Overview of the SKP 100 G3 plug-on transmitter .................................... 5  
Overview of the displays ................................................................................ 6  
Putting the plug-on transmitter into operation .......................................... 7  
Inserting the batteries/accupack ................................................................. 7  
Charging the accupack .................................................................................... 7  
Plugging the plug-on transmitter onto a microphone ............................. 7  
Using the plug-on transmitter ......................................................................... 8  
Switching the plug-on transmitter on/off ................................................. 8  
Deactivating the lock mode temporarily .................................................... 9  
Muting the audio signal or deactivating the RF signal ............................ 9  
Selecting a standard display ...................................................................... 10  
Using the operating menu ............................................................................. 11  
The buttons .................................................................................................... 11  
Overview of the operating menu ............................................................... 11  
Working with the operating menu ........................................................... 12  
Adjusting settings via the operating menu ............................................... 13  
The main menu “Menu” .............................................................................. 13  
The extended menu “Advanced Menu” ................................................... 14  
Synchronizing the plug-on transmitter with a receiver .......................... 17  
Cleaning the plug-on transmitter ................................................................. 18  
Recommendations and tips ........................................................................... 18  
If a problem occurs ... ....................................................................................... 19  
Accessories ......................................................................................................... 20  
Specifications .................................................................................................... 21  
Manufacturer Declarations ............................................................................. 22  
For more detailed information on the individual sections of  
this instruction manual, visit the SKP 100 G3 product page  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important safety instructions  
Important safety instructions  
Read this instruction manual.  
Keep this instruction manual. Always include this instruction manual  
when passing the device on to third parties.  
Heed all warnings and follow all instructions.  
Clean the device only with a slightly damp cloth.  
Do not place the device near any heat sources such as radiators, stoves,  
or other devices (including amplifiers) that produce heat.  
Only use attachments/accessories specified by Sennheiser.  
When replacement parts are required, only use replacement parts  
specified by Sennheiser or those having the same characteristics as the  
original part. Unauthorized substitutions may result in fire, electric  
shock, or other hazards.  
Refer all servicing to qualified service personnel.  
Servicing is required if the device has been damaged in any way, liquid  
has been spilled, objects have fallen inside, the device has been exposed  
to rain or moisture, does not operate properly or has been dropped.  
WARNING: To reduce the risk of short circuits, do not use the device near  
water and do not expose it to rain or moisture.  
Intended use  
Intended use of the ew 100 G3 series devices includes:  
having read these instructions especially the chapter “Important safety  
instructions”,  
using the devices within the operating conditions and limitations  
described in this instruction manual.  
“Improper use” means using the devices other than as described in these  
instructions, or under operating conditions which differ from those  
described herein.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
The SKP 100 G3 plug-on transmitter  
The SKP 100 G3 plug-on transmitter  
The SKP 100 G3 plug-on transmitter is part of the evolution wireless series  
generation 3 (ew G3). With this series, Sennheiser offers high-quality  
state-of-the-art RF transmission systems with a high level of operational  
reliability and ease of use. Transmitters and receivers permit wireless  
transmission with studio-quality sound.  
Features of the evolution wireless 100 G3 series:  
Optimized PLL synthesizer and microprocessor technology  
HDX noise reduction system  
Pilot tone squelch control  
Switching bandwidth of 42 MHz  
Increased immunity to intermodulation and interferences in multi-  
channel operation  
Areas of application  
The plug-on transmitter can be combined with the EM 100 G3 stationary  
receiver and the EK 100 G3 portable receiver. These receivers are available  
in the same UHF frequency ranges and are equipped with the same  
frequency bank system. This has the advantage that  
a transmission system is ready for immediate use after switch-on,  
several transmission systems can be operated simultaneously on the  
preset frequencies without causing intermodulation interference.  
Transmitter  
SKP 100 G3  
Combinable with ... Receivers  
all dynamic  
EM 100 G3 stationary receiver  
microphones  
We recommend  
using dynamic  
Sennheiser  
PEAK  
20.12 EM 100  
MHz  
MUTE  
40  
25  
10  
0
-10  
-20  
-30  
533.875  
RF  
AF  
P
microphones  
EK 100 G3 diversity receiver  
condenser micro-  
phones that are  
not phantom-  
powered, e.g.  
the Sennheiser  
K6 system  
The frequency bank system  
The plug-on transmitter is available in 6 UHF frequency ranges with  
1,680 transmission frequencies per frequency range:  
Range A:  
516 – 558  
Range G:  
566 – 608  
Range B:  
626 – 668  
Range C:  
734 – 776  
Range D:  
780 – 822  
Range E:  
823 – 865  
Each frequency range (A–E, G) offers 21 frequency banks with up to  
12 channels each:  
Channel 1 – frequency preset  
Channel 2 – frequency preset  
Frequency bank 1 ... 20  
Channel 12 – frequency preset  
Channel 1 – freely selectable frequency  
Channel 2 – freely selectable frequency  
Frequency bank U  
Channel 12 – freely selectable frequency  
Each of the channels in the frequency banks “1” to “20” has been factory-  
preset to a fixed transmission frequency (frequency preset).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Delivery includes  
The factory-preset frequencies within one frequency bank are intermodu-  
lation-free. These frequencies cannot be changed.  
For an overview of the frequency presets, please refer to the supplied  
frequency information sheet. Updated versions of the frequency informa-  
tion sheet can be downloaded from the SKP 100 G3 product page on our  
The frequency bank “U” allows you to freely select and store transmission  
frequencies. It might be that these transmission frequencies are not inter-  
modulation-free.  
Delivery includes  
The packaging contains the following items:  
1 SKP 100 G3 plug-on transmitter  
2 AA size batteries, 1.5 V  
1 instruction manual  
1 frequency information sheet  
1 RF power information sheet  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product overview  
Product overview  
Overview of the SKP 100 G3 plug-on transmitter  
³
·
»
¿
´
²
º
¾
µ
¸
³ Microphone input, XLR-3 socket  
Operation and battery status  
indicator, red LED  
(female, unbalanced)  
lit = ON  
flashing = LOW BATTERY  
· Mechanical locking ring of  
XLR-3 socket  
º ON/OFF button  
» Infra-red interface  
(serves as the ESC (cancel) key  
in the operating menu)  
¿ Display panel, backlit in orange  
´ UP button (̆)  
¾ MUTE switch  
² DOWN button (̄)  
µ SET button  
¸ Battery compartment cover  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product overview  
Overview of the displays  
After switch-on, the plug-on transmitter displays the standard display  
Frequency/Name”. For further illustrations and examples of the different  
standard displays, refer to page 10.  
The display backlighting is automatically reduced after approx. 20 seconds.  
MHz  
533.875  
ew100 G3  
P
MUTE  
AF  
Display  
Meaning  
Audio level “AF” Modulation of the plug-on transmitter with  
peak hold function.  
Frequency  
Name  
Current transmission frequency  
User selectable name  
Transmission  
icon  
RF signal is being transmitted  
Lock mode icon  
P” (pilot tone)  
MUTE”  
Lock mode is activated  
Pilot tone transmission is activated  
Microphone input is muted  
Charge status:  
Battery status  
approx. 100%  
approx. 70%  
approx. 30%  
charge status is critical,  
the red LOW BATTERY LED is  
flashing:  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Putting the plug-on transmitter into operation  
Putting the plug-on transmitter into  
operation  
Inserting the batteries/accupack  
For powering the plug-on transmitter, you can either use two 1.5 V AA size  
batteries or the rechargeable Sennheiser BA 2015 accupack.  
̈ Slide the battery compartment cover ¸ in the direction of the  
embossed arrow and open the cover ¸.  
¸
̈ Insert the two batteries or the accupack as shown below. Please  
observe correct polarity when inserting the batteries/accupack.  
¸
̈ Close the battery compartment.  
The battery compartment cover ¸ locks into place with an audible  
click.  
Charging the accupack  
̈ Remove the BA 2015 accupack (optional accessory).  
̈ Insert the BA 2015 accupack into the L 2015 charger (accupack and  
charger are optional accessories):  
The L 2015 charger can only charge the BA 2015 accupack. Stan-  
dard batteries (primary cells) or individual rechargeable battery  
cells cannot be charged.  
Plugging the plug-on transmitter onto a microphone  
̈ Plug the microphone’s XLR-3M socket onto the transmitter’s XLR-3F  
socket ³.  
³
·
̈ Tighten the locking ring · in the direction of the arrow.  
The transmitter uses the microphone body as an antenna – there-  
fore microphones with a metal casing should be used for best  
signal transmission.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the plug-on transmitter  
Using the plug-on transmitter  
To establish a transmission link, proceed as follows:  
1. Switch the diversity receiver on (see the instruction manual of the  
receiver).  
2. Switch the plug-on transmitter on (see below).  
The transmission link is established and the diversity receiver’s RF level  
display “RF” reacts.  
Switching the plug-on transmitter on/off  
º
To switch the plug-on transmitter on (online operation):  
̈ Press the ON/OFF button º.  
ON/OFF  
The plug-on transmitter transmits an RF signal. The red  
ON LED lights up and the standard display “Frequency/  
Name” appears on the display panel. The transmission icon ብ  
is displayed.  
You can switch the plug-on transmitter on and deactivate the  
RF signal on switch-on. For more information, see below.  
To switch the plug-on transmitter off:  
̈ If necessary, deactivate the lock mode (see page 9).  
̈ Press the ON/OFF button º until “OFF” appears on the  
ON/OFF  
display panel.  
The red ON LED goes off and the display panel turns off.  
When in the operating menu, pressing the ON/OFF button º will  
cancel your entry (ESC function) and return you to the current  
standard display.  
To switch the plug-on transmitter on and to deactivate the RF signal on  
switch-on (offline operation):  
̈ Press the SET button until “RF Mute On?” appears on the  
SET  
display panel.  
̈ Press the SET button.  
SET  
The transmission frequency is displayed but the plug-on  
transmitter does not transmit an RF signal. The transmission  
icon is not displayed.  
MHz  
533.875  
ew100 G3  
P
MUTE  
AF  
Use this function to save battery power or to prepare a plug-on  
transmitter for use during live operation without causing inter-  
ference to existing transmission links.  
To activate the RF signal:  
̈ Press the ON/OFF button.  
ON/OFF  
SET  
RF Mute Off” appears on the display panel.  
̈ Press the SET button.  
The transmission icon is displayed again.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the plug-on transmitter  
Deactivating the lock mode temporarily  
You can activate or deactivate the automatic lock mode via the “Auto  
Lock” menu item (see page 14). If the lock mode is activated, you have  
to temporarily deactivate it In order to be able to operate the plug-on  
transmitter:  
̈ Press the ON/OFF button.  
ON/OFF  
Locked” appears on the display panel.  
̈ Press the UP button (̆).  
Unlock?” appears on the display panel.  
SET  
̈ Press the SET button.  
The lock mode is temporarily deactivated.  
How you are using the plug-on transmitter determines how  
long the lock mode remains deactivated:  
When you are in the operating menu  
The lock mode remains deactivated until you exit the  
operating menu.  
When one of the standard displays is shown  
The lock mode is automatically activated after 10 seconds.  
The lock mode icon flashes prior to the lock mode being activated again.  
MHz  
533.875  
ew100 G3  
P
MUTE  
AF  
Muting the audio signal or deactivating the RF signal  
¾
The MUTE switch ¾ allows you to mute the audio signal or to deactivate  
the RF signal. Via the “Mute Mode” menu item, you can set the desired  
function of the MUTE switch ¾ (see page 15).  
Setting  
AF On/Off” ... to the left (position MUTE) Mutes the audio signal  
... to the right Unmutes the audio signal  
Slide the MUTE switch ¾ ... Function  
RF On/Off” ... to the left (position MUTE) Deactivates the RF signal  
(offline operation)  
... to the right  
Activates the RF signal  
(online operation)  
Disabled”  
No function  
̈ From the “Mute Mode” menu item, select the desired setting (see  
page 15).  
̈ Exit the operating menu.  
̈ Slide the MUTE switch ¾ to the left, to the position MUTE.  
The plug-on transmitter reacts as indicated in the table.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the plug-on transmitter  
The current state of the muting function or the RF signal is displayed on  
the display panel of the plug-on transmitter:  
MHz  
533.875  
ew100 G3  
P
MUTE  
AF  
Audio signal is muted  
Transmitter’s display panel:  
MUTEis displayed  
Audio signal is activated (muting is canceled)  
Transmitter’s display panel:  
MUTEis not displayed  
RF signal is deactivated  
Transmitter’s display panel:  
Transmission icon is not  
displayed, “MUTEis displayed  
RF signal is activated  
Transmitter’s display panel:  
Transmission icon is displayed,  
MUTEis not displayed  
You can also deactivate the RF signal on switch-on. For more infor-  
mation, refer to the chapter “Switching the plug-on transmitter  
on/off” on page 8.  
Using the ON/OFF button, you can also activate/deactivate the RF  
signal during operation. To do so, briefly press the ON/OFF button  
and proceed as described on page 8.  
Selecting a standard display  
̈ Press the UP button (̆)/DOWN button (̄) to select a  
standard display:  
Contents of the display Selectable standard display  
Frequency/Name”  
533.875MHz  
ew100 G3  
P
MUTE  
AF  
AF  
AF  
Channel/Frequency”  
Name/Channel”  
B.Ch: 20M.1H2z  
533.875  
P
MUTE  
ew100 G3  
B.Ch: 20.12  
P
MUTE  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the operating menu  
Using the operating menu  
The buttons  
Button  
Function of the button  
Press the ON/OFF  
button  
Switches the plug-on transmitter on and off  
Cancels the entry and returns to the current  
standard display (ESC function)  
ON/OFF  
Activates/deactivates the RF signal  
(special function, see page 9)  
Press the SET button  
Changes from the current standard display to  
the operating menu  
SET  
Calls up a menu item  
Enters a submenu  
Stores the settings and returns to the  
operating menu  
Press the UP button/  
DOWN button  
Selects a standard display  
Changes to the next/previous menu item  
Changes the setting of a menu item  
Overview of the operating menu  
Main menu  
“Menu”  
Sensitivity  
Frequency Preset  
Name  
Auto Lock  
Advanced  
Exit  
Extended menu  
“Advanced Menu”  
Tune  
Mute Mode  
Pilot Tone  
LCD Contrast  
Reset  
Software Revision  
Exit  
Display  
Function of the menu item  
Page  
Main menu “Menu”  
Sensitivity  
Adjusts the sensitivity “AF”  
13  
Frequency Preset Changes the frequency bank and the channel 13  
Name  
Enters the transmitter name  
14  
Auto Lock  
Activates/deactivates the automatic lock  
mode  
14  
Advanced  
Exit  
Calls up the extended menu “Advanced  
Menu”  
14  
Exits the operating menu and returns to the  
current standard display  
Extended menu “Advanced Menu”  
Tune  
Sets the transmission frequencies for the  
frequency bank “U”  
15  
15  
Special function: Sets a channel and a  
transmission frequency for the frequency  
bank “U”  
Mute Mode  
Pilot Tone  
Sets the mode for the MUTE switch  
15  
16  
Activates/deactivates the pilot tone  
transmission  
LCD Contrast  
Reset  
Adjusts the contrast of the display panel  
Resets the plug-on transmitter  
16  
16  
16  
Software Revision Displays the current software revision  
Exit  
Exits the extended menu “Advanced Menu”  
and returns to the main menu  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the operating menu  
Working with the operating menu  
If the lock mode is activated, you have to deactivate it In order to  
be able to work with the operating menu (see page 9).  
By way of example of the “Sensitivity” menu, this section describes how to  
use the operating menu.  
Changing from the current standard display to the operating  
menu  
̈ Press the SET button.  
SET  
The current standard display is replaced by the main menu.  
The last selected menu item is displayed.  
Selecting a menu item  
̈ Press the UP button (̆)/DOWN button (̄) to change to the  
Sensitivity” menu item.  
The current setting of the selected menu item is displayed:  
Menu  
Sensitivity  
–12 dB  
Changing and storing settings  
SET  
Menu  
Sensitivity  
– 12 dB  
Sensitivity  
–36 dB  
Sensitivity  
–12 dB  
Call up  
“Sensitivity”  
Select the desired  
setting  
Store the setting  
SET  
“Stored”  
̈ Press the SET button to call up the menu item.  
SET  
̈ Press the UP button (̆)/DOWN button (̄) to adjust the  
input sensitivity.  
̈ Press the SET button to store the setting.  
SET  
Canceling an entry  
̈ Press the ON/OFF button to cancel the entry.  
ON/OFF  
The current standard display appears on the display panel.  
To subsequently return to the last edited menu item:  
̈ Press the SET button repeatedly until the last edited menu  
SET  
item appears.  
Exiting a menu item  
̈ Change to the “Exit” menu item.  
Menu  
Exit  
̈ Confirm your selection.  
SET  
You return to the next higher menu level.  
To directly return to the current standard display:  
̈ Press the ON/OFF button.  
ON/OFF  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjusting settings via the operating menu  
Adjusting settings via the operating  
menu  
Make use of the possibility to adjust settings via the operating  
menu of your receiver and to transfer these settings to the plug-  
on transmitter.  
For more information, refer to the instruction manual of the  
receiver. The relevant information is marked with the sync icon.  
The main menu “Menu”  
Adjusting the input sensitivity – “Sensitivity”  
SET  
Menu  
Sensitivity  
– 12 dB  
Sensitivity  
–36 dB  
Sensitivity  
–12 dB  
Call up  
“Sensitivity”  
Select the desired  
setting  
Store the setting  
SET  
“Stored”  
Adjustment range: 0 to –48 dB, adjustable in steps of 6 dB  
The transmitter’s audio level display “AF” always indicates the audio level,  
even if the plug-on transmitter is muted, e.g. allowing you to check the  
adjusted sensitivity before live operation.  
B.Ch: 20M.1H2z  
533.875  
P
MUTE  
AF  
Input  
sensitivity  
adjusted ...  
Effect/display  
... too high  
Close talking distances, speakers with loud voices or  
loud music passages cause overmodulation in the trans-  
mission link. The audio level display “AFshows full  
deflection for the duration of the overmodulation.  
... correctly  
... too low  
The audio level display “AFshows full deflection  
only during the loudest passages.  
The transmission link is undermodulated. This results in  
a signal with high background noise.  
Adjust a low input sensitivity when using condenser microphones,  
adjust a high input sensitivity when using dynamic microphones.  
Selecting the frequency bank and the channel manually –  
“Frequency Preset”  
SET  
SET  
Frequency Preset  
B.Ch: 5.12  
Frequency Preset  
B.Ch: 1.12  
Menu  
Frequency Preset  
B.Ch: 5.12  
792.525MHz  
818.850MHz  
Call up “Frequency  
Preset”  
Select the frequency  
bank and confirm  
Select the channel;  
store the setting  
SET  
“Stored”  
When you are in the “Frequency Preset” menu item, the RF signal is  
deactivated.  
Overview of the frequency banks and channels:  
Frequency bank Channels  
Type  
1” to “20”  
up to 12 per  
System bank:  
frequency bank frequencies are factory-preset  
U”  
up to 12  
User bank:  
frequencies are freely selectable  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjusting settings via the operating menu  
When setting up multi-channel systems, please observe the following:  
Only the factory-preset frequencies within one frequency bank are inter-  
modulation-free (see page 17). Plug-on transmitter and receiver of a  
transmission link have to be set to the same frequency. It is vital to  
observe the notes on frequency selection on page 17.  
Entering a name – “Name”  
SET  
SET  
Menu  
Name  
Name  
Lichael  
Name  
Michael  
Lichael  
Call up “Name”  
Enter a character  
and confirm  
Enter a character;  
store the entry  
SET  
“Stored”  
Via the “Name” menu, you can enter a freely selectable name (e.g. the  
name of the performer) for the plug-on transmitter.  
The name can be displayed on the standard displays “Frequency/Name”  
and “Name/Channel”. The name can consist of up to 8 characters such as:  
letters (without pronounciation marks),  
numbers from 0 to 9,  
special characters and spaces.  
To enter a name, proceed as follows:  
̈ Press the UP button (̆)/DOWN button (̄) to select a  
character.  
̈ Press the SET button to change to the next segment/  
SET  
character or to store the complete entry.  
Activating/deactivating the automatic lock mode – “Auto Lock”  
SET  
Menu  
Auto Lock  
Active  
Auto Lock  
Inactive  
Auto Lock  
Active  
Store the setting  
Call up “Auto  
Lock”  
Select the desired  
setting  
SET  
“Stored”  
The lock mode prevents that the plug-on transmitter is accidentally  
switched off or programed during operation. The lock mode icon ቦ  
on  
the current standard display indicates that the lock mode is activated.  
̈ Press the UP button (̆)/DOWN button (̄) to select the  
desired setting.  
For information on how to use the lock mode, refer to page 9.  
The extended menu “Advanced Menu”  
Setting transmission frequencies and the frequency bank “U” –  
“Tune”  
When you have selected one of the system banks and then select the  
Tune” menu, the plug-on transmitter automatically switches to channel 1  
of the frequency bank “U”. In this case, “U.1” briefly appears on the display  
panel. Upon delivery, the channels of the frequency bank “U” are not  
assigned a transmission frequency.  
Via the “Tune” menu item, you can set a transmission frequency to be  
stored in the current channel or you can select a different channel in the  
frequency bank “U” and assign it a transmission frequency. It is vital to  
observe the notes on frequency selection on page 17.  
When you are in the “Tune” menu item, the RF signal is  
deactivated.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjusting settings via the operating menu  
Setting a transmission frequency for the current channel  
̈ Press the UP button (̆)/DOWN button (̄) until the “Tune”  
menu item appears.  
̈ Press the SET button.  
SET  
The frequency selection appears.  
SET  
SET  
Advanced Menu  
Tune  
Tune  
543 .200 MHz  
B.Ch: U. 1  
Tune  
548.200 MHz  
B.Ch: U. 1  
Call up “Tune”  
Select the MHz  
value and confirm  
Select the kHz  
value; store the  
setting  
SET  
“Stored”  
̈ Set the desired frequency.  
̈ Press the SET button.  
SET  
Your settings are stored.  
You are back to the operating menu.  
Selecting a channel and assigning this channel a frequency  
̈ Press the UP button (̆)/DOWN button (̄) until the “Tune”  
menu item appears.  
̈ Keep the SET button pressed until the frequency bank selec-  
SET  
tion appears.  
SET  
SET  
Tune  
Advanced Menu  
Tune  
Tune  
548.200 MHz  
B.Ch: U. 1  
548 .200 MHz  
B.Ch: U. 1  
548.200 MHz  
Call up “Tune”  
(special function)  
Select the frequency  
bank and confirm  
Select the channel;  
store the setting  
̈
Set the desired channel.  
Press the SET button.  
The frequency selection appears.  
SET  
̈
̈
Set the desired frequency.  
Setting the mode for the MUTE switch – “Mute Mode”  
SET  
Advanced Menu  
Mute Mode  
Mute Mode  
AF On/Off  
Mute Mode  
RF On/Off  
Call up  
“Mute Mode”  
Select the desired  
setting  
Store the setting  
SET  
“Stored”  
Mode  
Function  
AF On/Off”  
When the switch is in the MUTE position,  
no audio signal is transmitted.  
RF On/Off”  
Disabled”  
When the switch is in the MUTE position,  
the RF signal is deactivated.  
The muting function is deactivated.  
For information on how to use the MUTE switch ¾, refer to page 9.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjusting settings via the operating menu  
Activating/deactivating the pilot tone transmission –  
“Pilot Tone”  
SET  
Advanced Menu  
Pilot  
Pilot  
Pilot Tone  
A c t i v e  
I n a c t i v e  
Call up  
“Pilot Tone”  
Select the desired  
setting  
Store the setting  
SET  
“Stored”  
The plug-on transmitter adds an inaudible pilot tone to the audio signal.  
The receiver detects and evaluates the pilot tone, and is thus able to iden-  
tify the signal of the matching transmitter and mute all others. The pilot  
tone supports the receiver’s squelch function.  
Devices of the ew 100 G1 series (generation 1) do not support the pilot  
tone function. Therefore, please observe the following when combining a  
transmitter or receiver of the ew 100 G3 series (generation 3) with devices  
from an earlier evolution wireless generation:  
Transmitter  
Receiver  
w G3/ w G2  
Make sure to ...  
... activate the pilot tone  
function on both trans-  
mitter and receiver.  
w G3/ w G2  
... deactivate the pilot tone  
function on the ew 100 G3  
transmitter.  
w G3  
w G1  
w G1  
w G3  
... deactivate the pilot tone  
function on the ew 100 G3  
receiver.  
Adjusting the contrast of the display panel – “LCD Contrast”  
You can adjust the contrast of the display panel in 16 steps.  
Loading the factory-preset default settings – “Reset”  
SET  
Advanced Menu  
Reset  
Reset  
Yes  
Select the desired  
setting; apply the  
setting  
Call up “Reset”  
SET  
“Stored”  
When resetting the plug-on transmitter, only the selected settings for the  
pilot tone and for the frequency bank “U” remain unchanged.  
For an overview of the factory-preset default settings, refer to the  
supplied frequency information sheet.  
Displaying the software revision – “Software Revision”  
You can display the current software revision of the plug-on transmitter.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Synchronizing the plug-on transmitter with a receiver  
Synchronizing the plug-on transmitter  
with a receiver  
When synchronizing the plug-on transmitter with a receiver, please  
observe the following:  
̈ Only use a plug-on transmitter and a receiver from the same frequency  
range (see the type plate on the transmitter and the receiver).  
̈ Make sure that the desired frequencies are listed in the enclosed  
frequency information sheet.  
̈ Make sure that the desired frequencies are approved and legal in your  
country and, if necessary, apply for an operating license.  
Synchronizing the plug-on transmitter with the receiver –  
individual operation  
Upon delivery, the plug-on transmitter and the receiver are synchronized  
with each other. If, however, you cannot establish a transmission link  
between plug-on transmitter and receiver, you have to synchronize the  
channels of the devices.  
For information on automatic synchronization of the plug-on transmitter  
with the receiver (individual operation), refer to the instruction manual of  
the receiver. This information is marked with the  
icon.  
Alternatively, you can set the channel on the plug-on transmitter  
manually:  
̈ Make sure that you set the plug-on transmitter to the same frequency  
bank and the same channel as the receiver (see page 13).  
If you still cannot establish a transmission link, refer to the chapter “If a  
problem occurs ...” on page 19.  
Synchronizing plug-on transmitters with receivers –  
multi-channel operation  
Combined with ew 100 G3 receivers, ew 100 G3 plug-on transmitters can  
form transmission links that can be used in multi-channel systems. In  
order to ensure an intermodulation-free transmission, use the same  
frequency bank for all transmission links.  
For information on automatic synchronization of plug-on transmitters  
with receivers (multi-channel operation), refer to the instruction manual  
of your receiver. For more information on multi-channel operation, visit  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning the plug-on transmitter  
Cleaning the plug-on transmitter  
CAUTION! Liquids can damage the electronics of the plug-on  
transmitter!  
Liquids entering the housing of the device can cause a  
short-circuit and damage the electronics.  
̈ Keep all liquids away from the plug-on transmitter.  
̈ Use a slightly damp cloth to clean the plug-on transmitter from time to  
time. Do not use any solvents or cleansing agents.  
Recommendations and tips  
... for the plug-on transmitter  
For best results, make sure that the transmitter sensitivity is correctly  
adjusted.  
... for optimum reception  
Transmission range depends to a large extent on location and can vary  
from about 10 m to about 150 m. There should be a “free line of sight”  
between plug-on transmitter and receiving antennas.  
To avoid overloading the receiver, observe a minimum distance of 5 m  
between plug-on transmitter and receiving antennas.  
The plug-on transmitter uses the microphone body as an antenna –  
therefore microphones with a metal casing should be used for best  
signal transmission.  
... for multi-channel operation  
When operating a multi-channel system, you should only use the  
channels within one frequency bank. Each of the frequency banks “1”  
to “20” accommodates factory-preset frequencies which are inter-  
modulation-free.  
When using several transmitters simultaneously, interference can be  
avoided by maintaining a minimum distance of 20 cm between two  
transmitters.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If a problem occurs ...  
If a problem occurs ...  
Problem  
Possible cause  
Possible solution  
Plug-on transmitter  
cannot be operated,  
Locked” appears on  
the display panel  
Lock mode is  
activated  
Deactivate the lock mode  
(see page 9).  
No operation  
indication  
Batteries are flat or Replace the batteries or  
accupack is flat  
recharge the accupack  
(see page 7).  
No RF signal at the  
receiver  
Plug-on trans-  
mitter and receiver mitter to the same channel  
Set the plug-on trans-  
are not on the  
same channel  
as the receiver.  
Synchronize the plug-on  
transmitter with the  
receiver (see page 17).  
Transmissionrange Reduce the distance  
is exceeded  
between plug-on trans-  
mitter and receiving  
antennas.  
RF signal is deacti- Activate the RF signal  
vated (“RF Mute“) (see page 9).  
Receiver is muted  
Cancel the muting on the  
receiver (see the instruc-  
tion manual of the  
receiver).  
RF signal available,  
no audio signal,  
MUTE” appears on  
the display panel  
Plug-on trans-  
mitter is muted  
(MUTE)  
Cancel the muting  
(see page 9).  
Receiver’s squelch Reduce the squelch  
threshold is  
adjusted too high  
threshold setting on the  
receiver.  
Plug-on trans-  
mitter doesn’t  
transmit a pilot  
tone  
Activate or deactivate the  
pilot tone transmission  
(see page 16).  
Audio signal has a  
high level of back-  
ground noise or  
audio signal is  
distorted  
Plug-on trans-  
mitter’s sensitivity tivity (see page 13).  
is adjusted too  
Adjust the input sensi-  
low/too high  
If a problem occurs that is not listed in the above table or if the problem  
cannot be solved with the proposed solutions, please contact your local  
Sennheiser partner for assistance.  
To find a Sennheiser partner in your country, search at  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories  
Accessories  
The following SKP 100 G3 accessories are available from your specialist  
dealer:  
Cat. No.  
009950  
009828  
005232  
Accessory  
BA 2015 accupack  
L 2015 charger  
POP 1 pouch (with belt clip)  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Specifications  
RF characteristics  
Modulation  
wideband FM  
Frequency ranges  
516–558, 566–608, 626–668,  
734–776, 780–822, 823–865 MHz  
(A to E, G, see page 3)  
Transmission frequencies  
1,680 frequencies,  
tuneable in steps of 25 kHz  
20 frequency banks, each with up to  
12 factory-preset channels  
1 frequency bank with up to  
12 user programmable channels  
Switching bandwidth  
Nominal/peak deviation  
Frequency stability  
42 MHz  
±24 kHz/±48 kHz  
±15 ppm  
RF output power at 50 Ω  
Pilot tone squelch  
typ. 30 mW  
can be switched off  
AF characteristics  
Compander system  
Sennheiser HDX  
80–18,000 Hz  
AF frequency response  
Signal-to-noise ratio  
(1 mV RF, peak deviation)  
110 dBA  
THD  
0.9%  
Max. input voltage  
3.3 V  
rms  
Input impedance  
60 kΩ, unbalanced  
Adjustment range of input  
sensitivity  
48 dB,  
adjustable in steps of 6 dB  
Overall device  
Temperature range  
Power supply  
–10°C to + 55°C  
2 AA size batteries, 1.5 V  
or BA 2015 accupack  
Nominal voltage  
2.4 V  
Power consumption  
at nominal voltage  
typ. 180 mA  
with switched-off  
transmitter  
25 μA  
Operating time  
typ. 8 hrs  
Dimensions  
approx. 105 mm x 43 mm x 43 mm  
approx. 195 g  
Weight (incl. batteries)  
In compliance with  
Europe  
EMC  
Radio  
Safety  
EN 301489-1/-9  
EN 300422-1/-2  
EN 60065  
EN 62311 (SAR)  
Approved by  
Canada  
Industry Canada RSS 123  
IC: 2099A-G3SKP  
limited to 806 MHz  
FCC-Part 74  
USA  
FCC-ID: DMOG3SKP  
limited to 698 MHz  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufacturer Declarations  
Pin assignment of XLR-3 socket  
XLR-3 socket (female), unbalanced (Audio In)  
2
1
+
3
Manufacturer Declarations  
Warranty  
Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this  
product.  
For the current warranty conditions, please visit our web site at  
In compliance with the following requirements  
RoHS Directive (2002/95/EC)  
WEEE Directive (2002/96/EC)  
Please dispose of the plug-on transmitter at the end of its oper-  
ational lifetime by taking it to your local collection point or recy-  
cling center for such equipment.  
Battery Directive (2006/66/EC)  
The supplied batteries or rechargeable batteries can be recycled.  
Please dispose of them as special waste or return them to your  
specialist dealer. In order to protect the environment, only  
dispose of exhausted batteries.  
CE Declaration of Conformity  
0682  
R&TTE Directive (1999/5/EC)  
Before putting the device into operation, please observe the respective  
country-specific regulations.  
Statements regarding FCC and Industry Canada  
This device complies with Part 15 of the FCC Rules and with RSS-210 of  
Industry Canada. Operation is subject to the following two conditions: (1)  
this device may not cause harmful interference, and (2) this device must  
accept any interference received, including interference that may cause  
undesired operation.  
This equipment has been tested and found to comply with the limits for a  
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are  
designed to provide reasonable protection against harmful interference in  
a residential installation. This equipment generates, uses and can radiate  
radio frequency energy and, if not installed and used in accordance with  
the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a partic-  
ular installation. If this equipment does cause harmful interference to  
radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the inter-  
ference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to  
which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
This class B digital device complies with the Canadian ICES-003.  
Changes or modifications made to this equipment not expressly approved  
by Sennheiser electronic Corp. may void the FCC authorization to operate  
this equipment.  
Before putting the device into operation, please observe the respective  
country-specific regulations!  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sennheiser electronic GmbH & Co. KG  
Am Labor 1, 30900 Wedemark, Germany  
Printed in Germany  
Publ. 01/09  
529675/A01  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Stereo Receiver EM 1001 9 User Manual
Sharp CRT Television 27F540 User Manual
Singer Sewing Machine 1030 User Manual
Snapper Lawn Aerator 2395 User Manual
Socket Mobile Network Card SDIO User Manual
SSI America Computer Accessories 240000 User Manual
Stovax Indoor Fireplace 8687 User Manual
SUPER MICRO Computer Computer Hardware AOC SASLP MV8 User Manual
SysKonnect Network Card SK 98xx V20 User Manual
Tannoy Speaker TFX Powerd Subwoofer User Manual