EK 100
Instruction manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Important safety instructions .......................................................................... 2
The EK 100 G3 diversity receiver ..................................................................... 3
The frequency bank system .......................................................................... 3
Areas of application ........................................................................................ 4
Delivery includes .................................................................................................. 4
Product overview ................................................................................................. 5
Overview of the EK 100 G3 diversity receiver ............................................ 5
Overview of the displays ................................................................................ 6
Inserting the batteries/accupack ................................................................. 7
Charging the accupack .................................................................................... 7
Using the diversity receiver .............................................................................. 9
Selecting a standard display ..................................................................... 10
Using the operating menu ............................................................................. 11
The buttons .................................................................................................... 11
Overview of the operating menu ............................................................... 11
Working with the operating menu ............................................................ 12
The main menu “Menu” .............................................................................. 14
Cleaning the diversity receiver ..................................................................... 21
Recommendations and tips ........................................................................... 21
If a problem occurs ... ....................................................................................... 22
Accessories ......................................................................................................... 23
Specifications .................................................................................................... 23
Manufacturer Declarations ............................................................................. 24
Index .................................................................................................................... 26
For further information, visit the EK 100 G3 product page on
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Important safety instructions
Important safety instructions
• Read this instruction manual.
• Keep this instruction manual. Always include this instruction manual
when passing the product on to third parties.
• Heed all warnings and follow all instructions in this instruction manual.
• Use only a cloth for cleaning the product.
• Do not place the product near any heat sources such as radiators, stoves,
or other devices (including amplifiers) that produce heat.
• Only use attachments/accessories specified by Sennheiser.
• Refer all servicing to qualified service personnel.
Servicing is required if the product has been damaged in any way, liquid
has been spilled, objects have fallen inside, the product has been
exposed to rain or moisture, does not operate properly or has been
dropped.
• WARNING: To reduce the risk of short circuits, do not use the product
near water and do not expose it to rain or moisture.
Replacement parts
When replacement parts are required, be sure the service technician
uses replacement parts specified by Sennheiser or those having the same
characteristics as the original part. Unauthorized substitutions may result
in fire, electric shock, or other hazards.
Intended use
Intended use of the EK 100 G3 diversity receiver includes:
• having read these instructions especially the chapter “Important safety
instructions”,
• using the product within the operating conditions and limitations
described in this instruction manual.
“Improper use” means using the product other than as described in this
instruction manual, or under operating conditions which differ from those
described herein.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
The EK 100 G3 diversity receiver
The EK 100 G3 diversity receiver
This diversity receiver is part of the evolution wireless series generation 3
(ew G3). With this series, Sennheiser offers high-quality state-of-the-art
RF transmission systems with a high level of operational reliability and
ease of use. Transmitters and receivers permit wireless transmission with
studio-quality sound.
Features of the evolution wireless 100 G3 series:
• Optimized PLL synthesizer and microprocessor technology
• HDX noise reduction system
• Adaptive diversity technology
• Switching bandwidth of 42 MHz
• Scan function (Easy Setup) for scanning the frequency banks for unused
channels
Adaptive diversity
This diversity receiver uses the ground connection of the line cable as its
second antenna to provide improved reception.
The frequency bank system
The diversity receiver is available in 6 UHF frequency ranges with
1,680 receiving frequencies per frequency range:
Range A:
516 – 558
Range G:
566 – 608
Range B:
626 – 668
Range C:
734 – 776
Range D:
780 – 822
Range E:
823 – 865
Each frequency range (A–E, G) offers 21 frequency banks with up to
12 channels each:
Channel 1 – frequency preset
Channel 2 – frequency preset
Frequency bank 1 ... 20
Channel 12 – frequency preset
Channel 1 – freely selectable frequency
Channel 2 – freely selectable frequency
Frequency bank U
Channel 12 – freely selectable frequency
Each of the channels in the frequency banks “1” to “20” has been factory-
preset to a fixed receiving frequency (frequency preset). The factory-
preset frequencies within one frequency bank are intermodulation-free.
These frequencies cannot be changed.
For an overview of the frequency presets, please refer to the supplied
frequency information sheet. Updated versions of the frequency informa-
tion sheet can be downloaded from the EK 100 G3 product page on our
website at www.sennheiser.com.
The frequency bank “U” allows you to freely select and store receiving
frequencies. It might be that these receiving frequencies are not intermod-
ulation-free (see page 19).
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Delivery includes
Areas of application
The receiver can be combined with the following transmitters:
Bodypack
Plug-on
transmitter
Radio microphone
transmitter
SK 100
SKM 100
SKP 100
These transmitters are available in the same UHF frequency ranges and
are equipped with the same frequency bank system with factory-preset
frequencies. An advantage of the factory-preset frequencies is that
• a transmission system is ready for immediate use after switch-on,
• several transmission systems can be operated simultaneously on the
preset frequencies without causing intermodulation interference.
Delivery includes
The packaging contains the following items:
1 EK 100 G3 diversity receiver
2 AA size batteries, 1.5 V
1 CA 2 camera adapter
1 CL 100 line cable
1 CL 1 line cable
1 instruction manual
1 frequency information sheet
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Product overview
Product overview
Overview of the EK 100 G3 diversity receiver
·
³
»
Ƹ
´
¹
¸
¿
´
²
¶
µ
º
¾
µ
³ 3.5 mm jack socket (LINE), lockable
(the ground contact is used by antenna II)
· Antenna I
» Operation and battery status indicator, red LED
lit = ON
flashing = LOW BATT
¿ RF signal indication, green LED
lit = RF
´ Charging contacts
² SET button
¶ ̆/̄ rocker button (UP/DOWN)
º Battery compartment
¾ Battery compartment cover
µ Battery compartment catches
¸ Infra-red interface
¹ ON/OFF button with ESC function (cancel)
Ƹ Display panel, backlit in orange
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Product overview
Overview of the displays
After switch-on, the diversity receiver displays the “Frequency/Name”
standard display. For further illustrations and examples of the different
standard displays, refer to page 10.
The display backlighting is automatically reduced after approx. 20 seconds.
ቢ
ባ
ቤ
ብ
MHz
823.925
ቦ
ew100 G3
MUTE
RF AF
P
ቩ
ቨ
ቧ
Display
RF level “RF”
(Radio Frequency)
Meaning
ቢ
Diversity display:
Antenna input I is active
Antenna input II is active
RF signal level:
Field strength of the received signal
RF
Squelch threshold level
ባ Audio level “AF”
Modulation of the transmitter
Peak hold function
(Audio Frequency)
When the display shows full
deflection, the audio input level
is excessively high.
For details, see page 16.
AF
ቤ Frequency
Current receiving frequency (see page 16)
ብ Name
Freely selectable name of the receiver
(see page 16)
ቦ Lock mode icon
Lock mode is activated (see page 10)
ቧ Battery status
Charge status:
approx. 100%
approx. 70%
approx. 30%
charge status is critical, the red
LOW BATT LED » is flashing
:
»
ቨ Muting function
“Mute” is only displayed on the “Frequency/
Name” standard display (see page 10) when
the transmitter’s RF signal is deactivated.
The diversity receiver does then not output
an audio signal.
“MUTE”
or line output level
AF OUT
The line output level AF OUT is only
displayed on the “Frequency bank/Channel/
Name” standard display (see page 10).
ቩ Pilot tone “P”
Activated pilot tone evaluation
(see page 18)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Putting the diversity receiver into operation
Putting the diversity receiver into
operation
Inserting the batteries/accupack
For powering the diversity receiver, you can either use two 1.5 V AA size
batteries or the rechargeable Sennheiser BA 2015 accupack or the DC 2
power adapter (see “Accessories” on page 23).
̈ Open the battery compartment by pushing the two catches µ in the
direction of the arrows and open the cover ¾.
¾
µ
¾
´
̈ Insert the two batteries or the accupack as shown above. Please
observe correct polarity when inserting the batteries/accupack.
̈ Close the battery compartment by pressing on the center of the
cover ¾.
The battery compartment cover ¾ locks into place with an audible
click.
Charging the accupack
To charge the BA 2015 accupack:
̈ Insert the diversity receiver into the L 2015 charger (see “Accessories”
on page 23).
The L 2015 charger can only charge the combination BA 2015
accupack/diversity receiver. Standard batteries (primary cells) or
individual rechargeable battery cells cannot be charged.
Mounting the diversity receiver to a camera
Use the supplied CA 2 camera adapter to mount the receiver to a camera’s
flash mount.
̈ Determine where on the perforated plate ƹ the flash mount
adapter ƺ will need to be fastened so that the receiver can best be
attached to the camera.
ƺ
ƹ
ƻ
̈ At this position, place a square nut ƻ under the perforated plate ƹ.
̈ Fasten the flash mount adapter ƺ to the perforated plate ƹ using the
square nut ƻ.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Putting the diversity receiver into operation
̈ Lift one side of the belt clip Ƽ as shown.
Ƽ
̈ Press down the belt clip Ƽ at one fixing point and pull it out of the
receiver housing.
̈ Repeat for the other side.
̈ Place the perforated plate ƹ onto the rear of the receiver.
̈ Reinsert the belt clip Ƽ.
̈ Use one of the supplied line cables to connect the line input of the
camera to the socket ³.
³
The ground connection of the line cable serves as the antenna for
the second diversity section. For details on the connector assign-
ment, refer to the diagram on page 24.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the diversity receiver
Using the diversity receiver
To establish a transmission link, proceed as follows:
1. Switch the diversity receiver on (see next section).
2. Switch a transmitter on (see the instruction manual of the transmitter).
The transmission link is established and the receiver’s RF level display
“RF” ቢ reacts.
It is vital to observe the notes on frequency selection on page 19.
If you cannot establish a transmission link between transmitter and
receiver, read the chapter “Synchronizing a transmitter with the diversity
receiver” on page 19.
Switching the diversity receiver on/off
̈ Push the two battery compartment catches µ and open the battery
compartment cover ¾.
»
¹
µ
¾
µ
To switch the diversity receiver on:
̈ Press the ON/OFF button ¹.
The red ON LED » lights up and the standard display “Frequency/
Name” appears on the display panel.
To switch the diversity receiver off:
panel.
The red ON LED » goes off and the diversity receiver switches off.
When in the operating menu, pressing the ON/OFF button ¹ will
cancel your entry (ESC function) and return you to the current
standard display.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the diversity receiver
Deactivating the lock mode temporarily
You can activate or deactivate the automatic lock mode via the “Auto
temporarily deactivate it in order to be able to operate the receiver:
SET
̈ Press the SET button.
“Locked” appears on the display panel.
̈ Press the rocker button.
“Unlock?” appears on the display panel.
SET
̈ Press the SET button.
– When you are in the operating menu, the lock mode remains
deactivated until you exit the operating menu.
– When one of the standard displays is shown, the lock mode
is automatically activated after 10 seconds.
The lock mode icon ቦ flashes prior to the lock mode being activated again.
MHz
823.925
ew100 G3
MUTE
RF AF
P
Selecting a standard display
̈ Press the ON/OFF button to select a standard display.
ON/OFF
Contents of the display
Selectable standard display
“Frequency/Name”
MHz
823.925
with “MUTE” display ቨ
ew100 G3
MUTE
RF AF
P
“Frequency bank/Channel/Name”
B.Ch: 1. 1
ew100 G3
with display of the line output level
“AF OUT” ቨ
RF AF
P
0
For more detailed information, refer to the chapter “Overview of the
displays” on page 6.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the operating menu
Using the operating menu
A special feature of the Sennheiser ew G3 series is the consistent, intuitive
menu structure of transmitters and receivers. As a result, adjustments to
the settings can be made quickly – even in stressful situations, for example
on stage or during a live show or presentation.
The buttons
Button
Function of the button
Press the ON/OFF button • Switches the diversity receiver on and off
• Selects a standard display (see page 10)
ON/OFF
• Cancels the entry and returns to the current
standard display (ESC function)
Press the SET button
• Changes from the current standard display
to the operating menu
SET
• Calls up a menu item
• Enters a submenu
• Stores the settings and returns to the
operating menu
Press the rocker button • Changes to the next/previous menu item
• Changes the setting of a menu item
Overview of the operating menu
Main menu
“Menu”
“Easy Setup”
Sync
Reset List
Current List
Scan New List
Exit
Squelch
Easy Setup
Frequency Preset
Name
Extended menu
“Advanced Menu”
AF Out
Auto Lock
Advanced
Exit
Tune
Pilot Tone
LCD Contrast
Reset
Software Revision
Exit
Display
Function of the menu item
Page
Main menu “Menu”
Sync
Synchronizes a transmitter with the diversity
receiver
14
14
15
Squelch
Adjusts the squelch threshold
Easy Setup
Scans for unused frequency presets, releases
and selects frequency presets
Frequency Preset Sets the frequency bank and the channel
15
16
16
Name
Enters a freely selectable name
Adjusts the audio output level
AF Out
Auto Lock
Advanced
Exit
Activates/deactivates the automatic lock mode 16
Calls up the extended menu “Advanced Menu” 16
Exits the operating menu and returns to the
–
current standard display
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the operating menu
Display
Function of the menu item
Page
Extended menu “Advanced Menu”
Tune
Sets the receiving frequencies for the
frequency bank “U”
16
17
Sets the channel and the receiving frequency
for the frequency bank “U”
Pilot Tone*
LCD Contrast
Reset
Activates/deactivates the pilot tone evaluation 18
Adjusts the contrast of the display panel
18
18
18
–
Resets the settings made in the operating
menu
Software Revision Displays the current software revision
Exit
Exits the extended menu “Advanced Menu”
and returns to the main menu
Working with the operating menu
If the lock mode is activated, you have to deactivate it In order to
be able to work with the operating menu (see page 10).
By way of example of the “Frequency Preset” menu, this section describes
how to use the operating menu.
Changing from a standard display to the operating menu
SET
̈ Press the SET button.
The current standard display is replaced by the main menu.
The last selected menu item is displayed.
Selecting a menu item
̈ Press the rocker button to change to the “Frequency Preset”
menu item.
The current setting of the selected menu item is displayed:
Menu
Frequency Preset
B.Ch: 1. 1
Changing and storing settings
SET
SET
Frequency Preset
B.Ch: 1. 1
Frequency Preset
Menu
Frequency Preset
B.Ch: 1. 1
B.Ch:
2.
2
823.925MHz
823.925MHz
Call up “Frequency
Preset”
Select the frequency
bank and confirm
Select the channel;
store the setting
SET
“Stored”
SET
̈ Press the SET button to call up the menu item.
̈ Press the rocker button to set the frequency bank.
SET
SET
̈ Press the SET button to confirm your selection.
̈ Press the rocker button to set the channel.
̈ Press the SET button to store the setting.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the operating menu
Canceling an entry
̈ Press the ON/OFF button to cancel the entry.
ON/OFF
The current standard display appears on the display panel.
To subsequently return to the last edited menu item:
SET
̈ Press the SET button repeatedly until the last edited menu
item appears.
Exiting a menu item
To return to the next higher menu level:
̈ Change to the “Exit” menu item.
Menu
Exit
SET
̈ Confirm your selection.
You return to the next higher menu level.
To directly return to the current standard display:
̈ Press the ON/OFF button.
ON/OFF
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting settings via the operating menu
Adjusting settings via the operating
menu
The main menu “Menu”
Synchronizing a transmitter with the diversity receiver – “Sync”
You can synchronize a suitable transmitter of the ew 100 G3 series with
the diversity receiver. During synchronization, the following parameters
are transferred to the transmitter:
• Current receiving frequency (“Frequency Preset”, see page 15)
• Current name set for the receiver (“Name”, see page 16)
• Current pilot tone setting of the receiver (“Pilot Tone”, see page 18)
To transfer these parameters:
̈ Switch the transmitter and the diversity receiver on.
̈ On the receiver, call up the “Sync” menu item.
“Sync” appears on the display panel of the receiver.
̈ Place the infra-red interface of the transmitter (see the instruction
manual of the transmitter) in front of the infra-red interface of the
receiver ¸.
¸
The parameters are transferred to the transmitter. When the transfer
is completed, “ ” appears on the display panel of the diversity
receiver. The receiver then switches back to the current standard
display.
To cancel the transfer:
̈ Press the ON/OFF button ¹ on the receiver.
“ ” appears on the display panel of the receiver. “ ” also appears if:
– no transmitter was found or the transmitter is not compatible,
– no transmitter was found and the synchronization process was
canceled after 30 seconds,
– you canceled the transfer.
Adjusting the squelch threshold – “Squelch”
SET
Squelch
Squelch
Menu
Squelch
Low
High
Low
Call up “Squelch”
Select the
desired setting
Store the setting
SET
“Stored”
Adjustment range: “Low”, “Middle”, “High”, can be switched off
The squelch eliminates annoying noise when the transmitter is switched
off or when there is no longer sufficient transmitter power received by the
receiver.
̈ Adjust the squelch threshold – with the transmitter switched off – to
the lowest possible setting that suppresses hissing noise.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting settings via the operating menu
If the squelch threshold is set to “High”, the transmission range
will be reduced under unfavourable reception conditions.
The squelch should only be switched off for servicing purposes. With the
squelch threshold set to “Low”, you switch the squelch off by keeping the
DOWN rocker button pressed for 3 seconds.
Display
Squelch is ...
... switched on.
823.925MHz
ew100 G3
MUTE
ቫ
The dotted line ቫ displays the squelch
threshold.
RF AF
P
... switched off.
MHz
823.925
ቫ
The dotted line ቫ goes off and the audio
level display “AF” shows full deflection
(hissing noise).
ew100 G3
P
RF AF
If you have accidentally switched off the squelch:
̈ Press the UP rocker button to switch the squelch on.
Scanning for, releasing and selecting frequency presets –
“Easy Setup”
Menu item
Function of the menu item
Reset List
Releases all locked frequency presets
Current List Selects an unused frequency preset
Scan New List Automatically scans for unused receiving frequencies
(frequency preset scan). If receiving frequencies are used,
they will be locked; if receiving frequencies are unused,
they will be released. After the frequency preset scan,
you can select an unused frequency preset.
Selecting the frequency bank and the channel –
“Frequency Preset”
SET
SET
Frequency Preset
B.Ch: 1. 1
Frequency Preset
Menu
Frequency Preset
B.Ch: 1. 1
B.Ch:
2.
2
823.925MHz
823.925MHz
Call up “Frequency
Preset”
Select the frequency
bank and confirm
Select the channel;
store the setting
SET
“Stored”
When setting up multi-channel systems, please observe the
following:
Only the factory-preset receiving frequencies within one
frequency bank (“1” to “20”) are intermodulation-free. It is vital
to observe the notes on frequency selection on page 19.
Overview of the frequency banks and channels:
Frequency bank Channels
Type
“1” to “20”
up to 12 per
System bank:
frequency bank frequencies are factory-preset
“U”
up to 12
User bank:
frequencies are freely selectable
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting settings via the operating menu
Entering a name – “Name”
Menu
Name
Name
Lichael
Name
Michael
Lichael
Call up “Name”
Enter a character
and confirm
Enter a character;
store the setting
“Stored”
Via the “Name” menu, you can enter a freely selectable name (e.g. the
name of the performer) for the receiver. The name is displayed on the
standard display (see page 6). The name can consist of up to 8 characters
such as:
• letters (without pronounciation marks),
• numbers from 0 to 9,
• special characters and spaces.
To enter a name, proceed as follows:
̈ Press the rocker button to select a character.
SET
̈ Press the SET button to change to the next segment/character
or to store the complete entry.
Adjusting the audio output level – “AF Out”
SET
Menu
AF Out
AF Out
0 dB
AF Out
+ 6dB
0 dB
Call up “AF Out
”
Select the desired
setting
Store the setting
SET
“Stored”
Adjustment range: –30 dB to +12 dB, adjustable in 6-dB steps
Via the “AF Out” menu item, you can adjust the level of the audio output
Line from the receiver to the input of the connected camera.
Activating/deactivating the automatic lock mode – “Auto Lock”
SET
Menu
Auto Lock
Active
Auto Lock
Inactive
Auto Lock
Active
Store the setting
Call up
“Auto Lock”
Select the desired
setting
SET
“Stored”
The lock mode prevents that the diversity receiver is accidentally switched
off or programed during operation. The lock mode icon ቦ on the
current standard display indicates that the lock mode is activated. For
information on how to use the lock mode, refer to page 10.
The extended menu “Advanced Menu”
To get into the extended menu “Advanced Menu”:
̈ From the main menu, select “Advanced”.
Setting the receiving frequencies for the frequency bank “U” –
“Tune”
When you have selected one of the system banks and then select
the “Tune” menu, the diversity receiver automatically switches to
channel 1 of the frequency bank “U”. In this case, “U.1” briefly
appears on the display panel.
Upon delivery, the channels of the frequency bank “U” are not
assigned a receiving frequency.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting settings via the operating menu
Via the “Tune” menu item, you can set a receiving frequency to be stored
in the current channel or you can select a different channel in the
frequency bank “U” and assign this channel a receiving frequency.
Setting a receiving frequency for the current channel
̈ Press the rocker button until the “Tune” menu item appears.
SET
̈ Press the SET button.
The MHz section of the receiving frequency of the channel is
highlighted.
SET
SET
Advanced Menu
Tune
Tune
Tune
823.925 MHz
823.925 MHz
823.925 MHz
B.Ch: U1. 1
B.Ch: U1. 1
Call up “Tune”
(special function)
Select the frequency
bank and confirm
Select the channel;
store the setting
SET
“Stored”
It is vital to observe the notes on frequency selection on page 19.
̈ Press the rocker button to set the MHz section of the
frequency.
SET
SET
̈ Press the SET button to confirm the MHz section of the
frequency.
The kHz section of the frequency is highlighted.
̈ Press the rocker button to set the kHz section of the frequency.
̈ Press the SET button to confirm the frequency.
“Stored” appears on the display panel. The “Tune” menu item
appears again.
Selecting a channel and assigning this channel a frequency
̈ Press the rocker button until the “Tune” menu item appears.
SET
̈ Press the SET button and keep it pressed until the frequency
bank is highlighted.
SET
SET
Advanced Menu
Tune
Tune
Tune
823.925 MHz
823.925 MHz
823.925 MHz
B.Ch: U5. 1
B.Ch: U1. 1
Call up “Tune”
(special function)
Select the frequency
bank and confirm
Select the channel;
store the setting
SET
“Stored”
̈ Press the rocker button to set the channel.
SET
̈ Press the SET button to confirm the channel.
The frequency (MHz section) is highlighted.
̈ Set the desired frequency (MHz and kHz section) as described in the
previous chapter.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting settings via the operating menu
Activating/deactivating the pilot tone evaluation – “Pilot Tone”
Advanced Menu
Pilot
Pilot
Pilot Tone
A c t i v e
A c t i v e
I n a c t i v e
Call up
“Pilot Tone”
Select the desired
setting
Store the setting
“Stored”
The transmitter adds an inaudible signal, known as the pilot tone, to the
transmitted signal. The diversity receiver detects and evaluates the pilot
tone. The pilot tone supports the diversity receiver’s squelch function, thus
protecting against interference due to RF signals from other devices.
Display
Meaning
No icon
The pilot tone evaluation is deactivated.
The pilot tone evaluation is activated but the receiver does
not receive a pilot tone.
The pilot tone evaluation is activated. The receiver receives
a pilot tone.
Observe the following when combining a transmitter or receiver of the
ew 100 G3 series (generation 3) with devices from an earlier evolution
wireless generation:
Devices of the ew 100 G1 series (generation 1) do not support the
pilot tone function.
Transmitter
Receiver
w G3/ w G2
Make sure to ...
... activate the pilot tone function
on both transmitter and diversity
receiver.
w G3/ w G2
... deactivate the pilot tone function on
the ew 100 G3 transmitter.
w G3
w G1
w G1
w G3
... deactivate the pilot tone function on
the ew 100 G3 diversity receiver.
Adjusting the contrast of the display panel – “LCD Contrast”
Advanced Menu
LCD Contrast
7
LCD Contrast
1 0
LCD Contrast
7
Call up
“LCD Contrast”
Select the desired
setting
Store the setting
“Stored”
You can adjust the contrast of the display panel in 16 steps.
Resetting the settings made in the operating menu – “Reset”
SET
Advanced Menu
Reset
Reset
Yes
Call up “Reset”
Select the desired
setting; apply the
setting
SET
“Stored”
When resetting the settings made in the operating menu, only the
selected settings for the pilot tone and for the frequency bank “U” remain
unchanged. For an overview of the factory-preset default settings, refer to
the supplied frequency information sheet.
Displaying the software revision – “Software Revision”
You can display the current software revision of the diversity receiver.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Synchronizing a transmitter with the diversity receiver
Synchronizing a transmitter with the
diversity receiver
When synchronizing a transmitter with a diversity receiver, please
observe the following:
̈ Only use a transmitter and a diversity receiver from the same
frequency range (see the type plates on the transmitter and
the diversity receiver).
̈ Make sure that the desired frequencies are listed in the
enclosed frequency information sheet.
You can also contact your Sennheiser partner who will be
pleased to calculate intermodulation-free frequencies for you.
̈ Make sure that the desired frequencies are approved and legal
in your country and, if necessary, apply for an operating
license.
Upon delivery, transmitter and diversity receiver are synchronized with
each other. If, however, you cannot establish a transmission link between
transmitter and diversity receiver, you have to synchronize the channels of
the devices:
̈ Deactivate the RF signal on all transmitters (see the instruction manual
of the transmitter).
This prevents that, during the frequency scan, the channels used by
switched-on transmitters are displayed as “used”.
̈ With a diversity receiver, perform a frequency preset scan to scan the
frequency banks for unused channels (“Scan New List”, see page 15).
̈ Select a frequency bank and a channel on this diversity receiver
(“Current List”, see page 15).
If you want to set up a multi-channel system, select a frequency bank
with a sufficient number of unused channels for all planned transmis-
sion links.
̈ Synchronize a transmitter with the diversity receiver (see page 14).
The receiver’s frequency, name and pilot tone setting are transferred to
the transmitter.
OR:
̈ Manually set the transmitter to the same frequency bank and channel
that you set on the receiver.
̈ Activate the RF signal on this transmitter.
The transmission link is established.
If you want to set up a multi-channel system:
̈ Repeat the following 4 steps for each additional transmission link:
– Perform a frequency preset scan with the next diversity receiver.
– Select a channel from the same frequency bank as with the first
diversity receiver.
– Synchronize a transmitter with the diversity receiver.
– Activate the RF signal on the transmitter.
Using freely selectable receiving frequencies
You can also freely select the receiving frequencies and store these
frequencies in the frequency bank “U”.
It might be that the freely selected frequencies are not inter-
modulation-free
If you use frequencies from the frequency bank “U”, it might be
that the frequencies are not intermodulation-free.
̈ Contact your Sennheiser partner who will be pleased to
calculate intermodulation-free frequencies for you (see
̈ Set each diversity receiver to the frequency bank “U”.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Synchronizing a transmitter with the diversity receiver
̈ On one of the receivers, select a channel within this frequency bank and
assign this channel one of the calculated receiving frequencies (see
page 17).
̈ Synchronize a transmitter with this receiver (see page 14).
OR:
̈ Manually set the transmitter to the same frequency bank and channel
that you set on the receiver.
̈ Repeat for the remaining transmitters and receivers as described
above.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning the diversity receiver
Cleaning the diversity receiver
CAUTION!
Liquids can damage the electronics of the receiver!
Liquids entering the housing of the device can cause a
short-circuit and damage the electronics.
̈ Keep all liquids away from the receiver.
̈ Do not use any solvents or cleansing agents.
̈ Use a cloth to clean the diversity receiver from time to time.
Recommendations and tips
... for the diversity receiver
• Make sure that the antenna and the line cable do not cross.
• For best results, make sure that the transmitter sensitivity is correctly
adjusted.
... for optimum reception
• Transmission range depends to a large extent on location and can vary
from about 10 m to about 150 m. There should be a “free line of sight”
between transmitting and receiving antennas.
• To avoid overloading the receiver, observe a minimum distance of 5 m
between transmitting and receiving antennas.
... for multi-channel operation
• When operating a multi-channel system, you should only use the chan-
nels within one frequency bank. Each of the frequency banks “1” to
“20” accommodates factory-preset frequencies which are intermodu-
lation-free.
• The frequency bank “U” allows you to freely select and store receiving
frequencies (see page 16).
• When using several transmitters simultaneously, interference can be
avoided by maintaining a minimum distance of 20 cm between two
transmitters.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
If a problem occurs ...
If a problem occurs ...
Problem
Possible cause
Possible solution
Diversity
Lock mode is activated Deactivate the lock mode
(see page 10).
receiver cannot
be operated,
“Locked”
appears on the
display panel
No operation
indication
Batteries are flat or
accupack is flat
Replace the batteries or
recharge the accupack
(see page 7).
No RF signal
Transmitter and
Set the transmitter and
receiver are not on the receiver to the same channel.
same channel
Synchronize the transmitter
with the receiver
(see page 14).
Transmission range is Check the squelch threshold
exceeded
setting (see page 14).
Reduce the distance between
transmitter and receiver.
RF signal is
deactivated
(“RF Mute“)
Activate the RF signal
(see the instruction manual
of the transmitter).
RF signal avail- Transmitter is muted Cancel the muting
able, no audio
signal, “MUTE”
appears on the
display panel
(see the instruction manual of
the transmitter).
Receiver’s squelch
Reduce the squelch threshold
threshold is adjusted setting (see page 14).
too high
Transmitter doesn’t
Deactivate the pilot tone
transmit a pilot tone evaluation (see page 18).
Audio signal has Transmitter sensitivity Adjust the transmitter
a high level of
background
noise
is adjusted too low
sensitivity correctly
(see the instruction manual
of the transmitter).
Audio signal is Transmitter sensitivity Adjust the transmitter
distorted
is adjusted too high
sensitivity correctly
(see the instruction manual
of the transmitter).
Receiver’s audio
output level is
Reduce the audio output level
(“AF Out”, see page 16).
adjusted too high
No access to a During scanning,
certain channel an RF signal has
been detected on
Set the transmitter operating
on this channel to a different
channel and redo the
frequency preset scan
(see page 15).
this channel and
the channel has
been locked
During scanning, a
transmitter of your
Switch the transmitter off and
redo the frequency preset scan
system operating on (see page 15).
this channel has not
been switched off
If a problem occurs that is not listed in the above table or if the problem
cannot be solved with the proposed solutions, please contact your local
Sennheiser partner for assistance.
To find a Sennheiser partner in your country, search at
www.sennheiser.com under “Service & Support”.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessories
Accessories
The following EK 100 G3 accessories are available from your specialist
dealer:
Cat. No.
009950
009828
009827
009986
005022
087046
Accessory
BA 2015 accupack
L 2015 charger
DC 2 power adapter for external DC powering (12 V)
CA 2 camera adapter
CL 1 line cable (jack to jack)
CL 100 line cable (XLR-3 to jack)
Specifications
RF characteristics
Modulation
wideband FM
Frequency ranges
516–558, 566–608, 626–668,
734–776, 780–822, 823–865 MHz
(A to E, G, see page 3)
Receiving frequencies
1,680 frequencies, tuneable in steps
of 25 kHz
20 frequency banks, each with up
to 12 factory-preset channels
1 frequency bank with up to 12 user
programmable channels
Switching bandwidth
Nominal/peak deviation
Receiver principle
42 MHz
±24 kHz/±48 kHz
adaptive diversity
Sensitivity
(with HDX, peak deviation)
< 1.6 μV for 52 dBArms S/N
Adjacent channel rejection
typ. ≥ 65 dB
Intermodulation attenuation typ. ≥ 65 dB
Blocking
Squelch
≥ 70 dB
Off, Low: 5 dBμV, Middle: 15 dBμV,
High: 25 dBμV
Pilot tone squelch
can be switched off
AF characteristics
Compander system
Sennheiser HDX
S/N ratio
(1 mV, peak deviation)
≥ 60 dBA
THD
≤ 0.9%
AF output voltage
3.5 mm jack socket: +11 dBu
(at peak deviation, 1 kHz AF) (mono, unbalanced)
Adjustment range of audio
output level
42 dB, adjustable in steps of 6 dB
Overall device
Temperature range
Power supply
–10°C to +55°C
AA size batteries, 1.5 V
2
or BA 2015 accupack
Nominal voltage
2.4 V
Power consumption:
• at nominal voltage
typ. 140 mA
• with switched-off receiver ≤ 25 μA
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Manufacturer Declarations
Operating time
typ. 8 hrs
Dimensions
approx. 82 x 64 x 24 mm
approx. 120 g
Weight (incl. batteries)
In compliance with
Europe
EMC:
EN 301489-1/-9
Radio: EN 300422-1/-2
Safety: EN 60065
USA
47 CFR 15 subpart B
Approved by
Canada
Industry Canada RSS 123
IC 2099A-G3EK100
limited to 806 MHz
Connector assignment
3.5 mm jack plug
wired stereo
wired mono
+ NC
+
Manufacturer Declarations
Warranty
Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this
product.
For the current warranty conditions, please visit our website at
In compliance with the following requirements
• RoHS Directive (2002/95/EC)
• WEEE Directive (2002/96/EC)
Please dispose of the diversity receiver at the end of its opera-
tional lifetime by taking it to your local collection point or recy-
cling center for such equipment.
• Battery Directive (2006/66/EC)
The supplied batteries or rechargeable batteries can be recycled.
Please dispose of them as special waste or return them to your
specialist dealer. In order to protect the environment, only
dispose of exhausted batteries.
CE Declaration of Conformity
•
0682
• R&TTE Directive (1999/5/EC)
Before putting the device into operation, please observe the respective
country-specific regulations.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Manufacturer Declarations
Statements regarding FCC and Industry Canada
This device complies with Part 15 of the FCC Rules and with RSS-210 of
Industry Canada. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a partic-
ular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This class B digital device complies with the Canadian ICES-003.
Changes or modifications made to this equipment not expressly approved
by Sennheiser electronic Corp. may void the FCC authorization to operate
this equipment.
Before putting the device into operation, please observe the respective
country-specific regulations!
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Index
Accessories 23
O
Accupack
charging
inserting
7
7
Operating menu
overview 11
settings 14
using 12
P
Advanced Menu (extended menu)
overview 12
settings 16
Pilot Tone (activating/deactivating
AF Out (adjusting the audio output
the pilot tone
evaluation) 18
R
level) 16
Auto Lock (activating/deactivating
the lock mode) 16
Receiver
cleaning 21
mounting to a camera
B
Batteries
7
battery status
inserting
Buttons
function of the ~ 11
ON/OFF button
SET button
UP/DOWN button
6
switching off
switching on
9
9
7
Reset (resetting the settings made
5
RF signal indication
S
5
5
C
Software Revision (displaying the
software revision) 18
Channel
assigning a frequency 17
selecting 15
Squelch (adjusting the
squelch) 14
setting a frequency 17
Sync (synchronizing a transmitter
D
with the receiver) 14
Displays
adjusting the contrast of the dis-
T
Transmitter (synchronizing with
play panel (LCD Contrast) 18
AF (audio level)
AF OUT
LOW BATT
MUTE
RF (RF level)
standard displays 10
receiver) 19
6
Troubleshooting 22
6
Tune (setting the receiving
bank “U”) 16
6
6
6
E
Easy Setup (scanning for, releasing
and selecting frequency
presets) 15
F
Frequency bank
selecting 15
setting a frequency 17
~ system
3
Frequency Preset (selecting a
frequency bank/
channel) 15
Frequency presets
releasing (Reset List) 15
searching for unused ~ (Scan New
List) 15
selecting (Current List) 15
L
Lock mode
activating/deactivating (Auto
Lock) 16
deactivating temporarily 10
lock mode icon
6
Locked 10
LOW BATT
5
M
Menu (main menu)
overview 11
settings 14
N
26
Download from Www.Somanuals.com. All Manuals Search And Download.
|