SPX Cooling Technologies Refrigerator MarleyAV Series User Manual

MarleyAV Series CoolingTower  
/
/
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
/
/
AV Air Movement System  
n Streamlined eased inlet fan cylinder  
assures full area, low turbulence airflow  
through the cylinder.  
n Heavy duty aluminum alloy fan–  
adjustable pitch blades.  
n 7.5 hp and larger fans are driven by a  
high quality, solid backed, multi-grooved  
neoprene and polyester v-belt thru a  
corrosion resistant aluminum alloy fan  
sheave.  
n Heavy duty, self-aligning, grease  
lubricated roller bearings selected with  
an L design life of 50,000 to 100,000  
10  
hours support the fan and shaft.  
n TEFC fan motor, 1.15 service factor,  
variable torque design, specially insulated  
for cooling tower duty.  
n The AV air movement system is  
guaranteed against failure for a period  
of five full years from date of shipment.  
Includes fan, fan shaft, bearings and  
mechanical equipment support.  
AVWater Distribution System  
AV Structure  
n Gravity flow distribution system. Easy, nonrestrictive  
maintenance. Basin covers are standard.  
n Crossflow configuration — easier and safer to inspect,  
service and maintain.  
n Marley SpiralTarget polypropylene nozzles for  
consistent, predictable water distribution.  
n G-235 heavy galvanized steel. Also available in 300  
stainless steel.  
n Marley MX thermoformed PVC film fill is suspended  
from the upper tower structure by heavy galvanized  
steel support members providing clearance between fill  
and sloping self-cleaning collection basin floor for easy  
basin cleaning. Integral eliminators and louvers keep  
circulating water confined to fill over a wide range of air  
flow rates.  
n Factory-assembled modules, including fan cylinders  
— makes final field installation hassle-free.  
n Large Access Doors—the generous plenum region in  
the AV tower is nonconfining, permitting quick visual  
inspection of cold water basin, internal structure, drift  
eliminators and mechanical equipment.  
Note: For economical transportation, AV towers are also  
available unassembled and crated for export.  
For Safety Reasons—always shut down and lock out the  
fan motor before entering the plenum.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Equipment and Accessories  
/
/
Enhance your AV tower installation with options and accessories that will improve the operation, longevity,  
maintenance, and accessibility of your cooling tower.  
n
n
Stainless Steel Distribution Basin  
Corrosion is usually most aggressive in the  
hot water distribution basins—stainless steel  
provides assurance of long, trouble-free service  
life.  
External Service Platform  
Provides easy access to distribution system  
without increasing installed height of tower.  
Platform with OSHA guardrails is Factory  
Mounted, eliminating installation labor cost and  
time. Field-installed ladder with optional safety  
cage for easy access.  
n
Marley Control System Package  
Factory-wired, factory-installed, factory-tested  
control center in NEMA 3R enclosure mounted  
on tower casing near access door. Complete  
with thermostat controller for single or two-  
speed motors to maintain chosen cold water  
temperature.  
n
Stainless Steel Collection Basin  
All collection basin parts in the wetted area—  
including structural members projecting in the  
basin, assembly and attaching hardware, and  
all basin options, are heavy-gauge Series 300  
stainless steel.  
n
InletTrash Screens  
Factory-installed, U-edged, galvanized wire mesh  
screens work in concert with the internal cellular  
louvers.  
The AV Engineering Data and Specifications  
Manual AV-TS provides engineering sche-  
matics, data, and information necessary for  
initial tower layout and details the tower in  
the form of specification language, providing  
technical as well as common-sense informa-  
tion on the importance of your specifica-  
tions. Available on the web at spxcooling.  
com or see your Marley sales representative  
for a copy.  
The Marley UPDATEweb-based application  
software provides model selections perfectly  
tuned to your cooling water system. Func-  
tions include model selection, specifications,  
model optimization, performance curves,  
engineering data, and free cooling applica-  
tions. Available to both registered customers  
and guests at spxcooling.com.  
If we can help in any way, feel free to call.  
To nd the Marley representative nearest  
you call 1 800 462 7539 or check the web at  
spxcooling.com.  
7401 WEST 129 STREET  
OVERLAND PARK, KANSAS 66213  
UNITED STATES  
913 664 7400  
spxcooling.com  
In the interest of technological progress,  
all products are subject to design and/or  
material change without notice.  
©2008 SPX Cooling Technologies, Inc.  
Printed in USA | AV-07A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shure Stereo Equalizer DP11EQ User Manual
Soleus Air Electric Heater HM2 15 32 User Manual
Sony Blu ray Player BDP S360 User Manual
Sony Car Video System XVM 750WEX User Manual
Sony Clock Radio ICF C414 User Manual
Sony CRT Television KV T29SN81 User Manual
Sony Microcassette Recorder M 2020 User Manual
Speco Technologies Portable Speaker SP RK65CB T User Manual
Star Manufacturing Kitchen Grill GR14SPTA User Manual
Sungale Digital Photo Frame PF703 User Manual