SIIG Printer 101828 User Manual

Instruction Manual  
In-Transit FlashLinkData Logger  
In-Transit FlashLinkSoftware  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
INTRODUCTION..........................................................................................1  
In-Transit FlashLink Software Features .....................................................2  
Data Logger Features..................................................................................3  
SETUP............................................................................................................4  
Minimum PC Requirements........................................................................4  
Connecting to Your Computer ....................................................................4  
Software Installation...................................................................................5  
Instructions for Win 98/95/3.1 ....................................................................5  
Instructions for Windows 2000, XP and NT...............................................7  
Port Settings................................................................................................8  
Windows 98/95 .........................................................................................10  
Windows 3.1 .............................................................................................10  
Windows NT.............................................................................................11  
Windows XP .............................................................................................12  
OPERATING INSTRUCTIONS..................................................................13  
Starting the Data Logger...........................................................................13  
Main Screen Description ..........................................................................13  
Customize Screen .....................................................................................15  
Auto Backup.............................................................................................16  
Download Data.........................................................................................17  
Shadow Logging.......................................................................................17  
Time Zone Map ........................................................................................18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data Tag Information............................................................................... 19  
Downloading............................................................................................ 20  
Graphs and Reports.................................................................................. 24  
Graphs ...................................................................................................... 24  
Reports ..................................................................................................... 26  
Current Status Screen............................................................................... 27  
Email........................................................................................................ 28  
LED INDICATORS .................................................................................... 29  
ERROR AND WARNING MESSAGES..................................................... 30  
Current Status Logger Messages.............................................................. 33  
TROUBLESHOOTING............................................................................... 34  
APPENDICES  
Product Specifications ................................................................................. 35  
In-Transit FlashLink Data Logger Models Available.............................. 36  
Hardware Compatibility........................................................................... 37  
Additional Connection Options ............................................................... 38  
Warranty .................................................................................................. 39  
Limitation of Liability.............................................................................. 39  
Contacting DeltaTRAK, Inc. ................................................................... 40  
Post Trip Calibration and Technical Support ........................................... 40  
Customer Service ..................................................................................... 40  
Website..................................................................................................... 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
The In-Transit FlashLink Data Logger is a single use instrument designed with a  
unique, patented communications feature via the PC’s parallel port, which  
allows an extremely fast data download (typically 760 data points per second).  
The 25-pin cable (included) connects FlashLink to your computer’s parallel  
(printer) port. . (A Serial Port Adapter is available for computers that do not  
have a parallel port) The PC time and date is used to track data history to the last  
data point collected. The software will automatically tabulate and graph the  
collected data.  
You will need both the FlashLink Data Logger and In-Transit FlashLink  
Software properly installed and configured for use. Refer to page  
5“Software Installation” and follow the instructions to install the In-Transit  
FlashLink Software onto your PC. The software can also be downloaded  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In-Transit FlashLink Software Features  
Single Windows-based user-friendly program for downloading, graphing, and  
reporting.  
Patented design downloads 3800 data points in 5 seconds on average.  
Capable of communicating through either Parallel or Serial Ports.  
Patented shadow logging design. (See page 17).  
Embedded independent email engine, eliminating the need for additional  
email software such as Microsoft Outlook.  
Automatic file naming, point-and-click interface, single-point connection to a  
PC and other easy-to-use features allow even non-technical users to download  
data quickly.  
The program allows easily customization with your company name and logo,  
time zone, temperature scale, and other operational preferences.  
Data can be saved as a text delimited file for insertion into any spreadsheet or  
database program.  
Status monitoring screen checks data logger activity status without disturbing  
operation except if the log interval is less than 20 seconds.  
FlashLink Data Loggers are Year 2000 compatible.  
Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data Logger Features  
Non-volatile data memory – data can be recovered after power loss.  
Standard 25-pin connector for downloading data to the PC; communicates  
with PC through parallel printer port. (Optional Serial Port Adapter  
Available)  
Green and red LEDs indicate whether the data logger is in active mode or  
alarm mode.  
Internal temperature sensor or external probe option  
Patented utility packaging for hanging, probe storage, and PC access  
Shock resistant ABS plastic case construction  
CE mark certified by TÜV  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETUP  
Minimum PC Requirements  
IBM (or compatible) 486 with 4 megabytes of memory. The In-Transit  
FlashLink Software runs on all versions of Windows (3.1, 95, 98, 2000, ME, XP  
and NT). It will also run on Windows LAN servers if the “client computers” use  
Windows 3.1, 95, or 98.  
Some brands of laptop computers may not be compatible with the In-Transit  
FlashLink Software. See page 36 of this manual for a list of compatible laptop  
computer models or call DeltaTRAKCustomer Service for the latest  
information. . The optional Serial Port Adapter will make most computers  
compatible.  
Connecting to Your Computer  
The recommended connection method is to use a standard 25-pin PC data cable,  
serial or parallel, with male on one end and female on the other. Remove the  
printer cable from the PC. Connect male end of the data cable to the back of the  
computer. The female end can be connected to the printer or to the data logger  
as needed.  
The data logger can be connected directly to the PC’s parallel (printer) port on a  
laptop or desktop computer, but mounting hardware on the PC may get in the  
way of making a reliable connection.  
IMPORTANT: Do not turn on your computer or reboot with a data logger  
connected to your PC as it may cause loss of data.  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Installation  
Instructions for Win 98/95/3.1  
1. Check the date and time setup in your computer. It is extremely important  
to have the correct information in your computer before installing the  
program disk or downloading the data to the PC.  
2. IF you have downloaded the software from www.DeltaTRAK.com, double  
click the FLITFULLx_x.exe icon; (x_x indicates the version #) click “Yes”  
to continue. Go to step 4.  
3. If you have the Installation CD, insert the In-Transit FlashLink Software  
Installation CD into your CDROM drive.  
(If the program does not open automatically, follow the instructions below.)  
Windows 95/98  
a. Go to Start.  
b. Choose Run.  
Windows 3.1  
a. Go to File Manager.  
c. Type D:\Disk1\Setup.exe (if the CD drive is D:\)  
d. Press Enter.  
4. The computer will start loading the program. Read the Welcome message,  
then click on Next to continue.  
5. User Information Screen:  
The registered owner of the computer may already appear in the fields, or  
you may type in your name and company name. Click on Next to accept the  
settings and continue.  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Choose Destination Location:  
C:\Flash is automatically entered as the default directory. To change the  
destination, click on Browse. Select the directory you want, then click on  
Next to accept the settings and continue.  
7. Select Program Folder:  
The “In-Transit FlashLink Software” folder is automatically entered as the  
default program folder. You can also select an existing folder from the list.  
Click on Next to accept the settings and continue.  
8. Start Copying Files:  
The settings that you just entered are displayed. Click on Back to make  
changes. Click on Next to accept the settings and continue. If installing  
from diskette, continue to next step, else go to Step 9.  
9. Two program versions are included. Email (EFlit.exe) and non-Email  
(Flit.exe).  
10. The icon for the Email and non Email versions are automatically created.  
To place an icon onto your Desktop, press and hold CTRL, then click on the  
icon (EFlit or Flit) and drag it out of the Flash window.  
11. Windows 3.1 systems may show the message “Cannot load OLE2.DLL”,  
click OK and continue.  
12. Reboot the PC.  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Windows 2000, XP and NT  
To install FlashLink Program Manager Software on Windows 2000, XP and NT:  
*Network Users: See your LAN Administrator.  
1. Restart the computer and log on as the Administrator. (You cannot install  
the software in of these Windows NT based systems without having  
Administrator access).  
2. IF you have downloaded the software from www.DeltaTRAK.com, double  
click the FLITFULLx_x.exe icon; (x_x indicates the version #) click “Yes”  
to continue. Go to step 8.  
3. If you have the Installation CD, insert the In-Transit FlashLink Software  
Installation CD into your CDROM drive.  
(If the program does not open automatically, follow the instructions below.)  
4. Go to Start  
5. Choose Run  
6. Type D:\Disk1\setup.exe (if the CD Drive is D:\)  
7. Press Enter  
8. The computer will start loading the program. Read the welcome message  
and click on Next to continue.  
If you have an error when trying to access the FlashLink logger, insure that you  
have administrator privileges before installing the software. If the problem  
persists, check the port settings for your computer.  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Settings  
The parallel port drive will try to allocate the parallel port with FlashLink  
automatically with the first run of the FlashLink software under the following  
conditions:  
Standard port address assignment  
a) One parallel port configuration  
LPT1 address: 0x378  
b) More than one parallel port configuration  
LPT1 address: 0x3BC  
LPT2 address: 0x378  
LPT3 address: 0x278  
In all non-standard cases the user has to specify explicitly the LPT address of the  
parallel port used with the FlashLink. This can be done using the Customize  
Screen Æ Port Setup. (See next page for illustration.)  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1) First click  
“Customize” for  
the “Customize”  
setup screen  
3) Click  
here to  
select the  
LPT and  
Base  
Address  
OR  
4) Click  
here to  
use the  
optional  
Serial  
2) Then  
click  
“SetPort”  
for “Port  
Settings”  
screen.  
Port  
Adapter  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Windows 98/95  
To check your port settings in Windows 98/95/3.1, do the following:  
1. Press start button, go to setting then control panel.  
2. Double click on system icon.  
3. Click on device manager tab.  
4. Click on ports.  
5. Double click on port you wish to use for FlashLink and write down  
port number.  
6. Click on resources tab.  
7. Write down first number of the first input/output range line. Should be  
something like 3BC. This is your base address.  
Then start your FlashLink Software and select from the top menu “Customize”.  
Then click the “Set Port” button. You will see the port-setting value that  
FlashLink Software is using in the “Base Address” field. Put the port-setting  
value that you wrote down from the above instructions into the “Base Address”  
field.  
Windows 3.1  
Uses Standard port configuration.  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Windows NT  
To check your port settings in Windows NT, do the following:  
1. Go to “Start”.  
2. Choose “Programs”.  
3. Choose “Administrative Tools”.  
4. Choose “Window NT Diagnostic”.  
5. Select the “Resources Tab”.  
6. Select the “I/O port” button.  
This will display the port settings for LPT1 where the FlashLink can be  
accessed. They should look something like 03BC, write this down.  
Then start your FlashLink Software and select from the top menu “Customize”.  
Then click the “Set Port” button. You will see the port-setting value that  
FlashLink Software is using in the “Base Address” field. Put the port-setting  
value that you wrote down from the above instructions into the “Base Address”  
field.  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Windows XP  
To check your port settings in Windows XP, do the following:  
1. Go to “Start”.  
2. Choose “Control Panel”.  
3. Choose “Administrative Tools”.  
4. Choose “Computer Management”  
5. Double click “Device Manager” in the left quadrant.  
6. Double click “Ports (COM & LPT)” icon in the right quadrant.  
7. Double click “Printer Port (LPT1)” icon in the right quadrant.  
8. Click the “Resources” tab.  
This will display the port settings for LPT1 where the FlashLink can be  
accessed. They should look something like “0378-037F”, write down “0378”.  
Then start your FlashLink Software and select from the top menu “Customize”.  
Then click the “Set Port” button. You will see the port-setting value that  
FlashLink Software is using in the “Base Address” field. Put the port-setting  
value that you wrote down from the above instructions into the “Base Address”  
field.  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
Starting the Data Logger  
The data logger must be started by the shipper by inserting a ballpoint pen or  
other small blunt object into the start switch hole on the front of the data logger.  
The green LED will flash rapidly three times to indicate it started. If the green  
LED does not flash, press the start switch again. If the data logger still does not  
activate after three tries, contact your distributor or DeltaTRAK, Inc., for  
technical assistance.  
Main Screen Description  
With the In-Transit FlashLink Software you can download data, open existing  
data files on the computer, manipulate data presentation, create graphs, and print  
reports. All functions are customizable and accessible from the main screen.  
Double click on the FlashLink icon “EFLIT” or “Flit” to start the program.  
Menu  
Click to open  
Setup Window  
Click to open  
an existing data  
file on the  
computer.  
Click to  
The Help Line  
provides prompts  
when the cursor is  
placed over an  
object.  
download  
data from a  
data logger  
Click to close pop-up window and  
either open an existing data file or  
download data from data logger  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menu Bar  
File  
Customize  
Open Data File: Open an existing  
(previously saved) data file on the  
computer.  
Select to set your preferences for  
company name, logo, on-line help,  
temperature scale, and graph and  
reporting defaults. Proceed to  
page 14 for complete information  
on the Customize Screen.  
Download Data: Download data  
from a data logger to the PC.  
Proceed to page 15.  
NOTE: This can only be accessed  
from the Main Menu.  
View Current Status: Check the  
status of the data logger. Proceed  
to page 26.  
Email Data File: Proceed to  
page 27.  
Icon Bar  
Open a previously saved  
data file on the computer  
Download data from the data  
logger  
View current status of  
data logger  
Software version  
Email data  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Customize Screen  
You can customize how the software works and the look of your data. The  
information can be updated or changed later, if desired. (Click “Customize” on  
the menu bar to open the window shown below.)  
Enter your company name  
Click here to  
search and select  
from available  
.bmp files.  
Enter the file name for  
your logo (it must be in  
.bmp format). Your  
logo will appear on the  
printed reports, if  
desired.  
Click here to  
select the  
temperature scale.  
Click to select or de-  
select actions. The  
selections may be  
changed at any time  
after starting the  
program.  
Click here to  
change the port  
setting for the  
printer.  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Auto Backup  
Data files are automatically saved when they are downloaded. The directory is  
named Databack, and is automatically created in the program’s “Flash”  
directory with your first download.  
If the custom option “Always ask for backup file name” is checked (to check:  
click “Customize” on the top menu bar), you may use whatever naming  
convention you wish (Up to 8 characters). You will be prompted to name each  
file as it is saved. Choosing Cancel at this point will still save the file, however,  
it will be saved using the automatic naming convention described below.  
If the custom option “Always ask for backup file name” is not checked, the data  
files will be named automatically using the data logger’s serial number. A  
numbered extension is added each time that particular data logger is  
downloaded. Therefore, downloading data logger number 00000403 three times  
will give you file names of 00000403, 00000403.001, and 00000403.002.  
The software will give you another chance to save the data in case you have  
changed computers, deleted files, etc. When the screen asks, “Data has been  
already saved! Continue Auto Backup anyway?” you can click OK to save the  
data again or Cancel to proceed without resaving.  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download Data  
Downloading can be done several ways. Connect the data logger to the data  
cable and do one of the following.  
Click on the Data Logger illustrated on the Main Screen, or  
Select File, Download Data, or  
Click the icon.  
You will be guided through the time zone selection and data tag screens.  
Note: If the custom option “Always show help info before download” is  
checked, the screen will display helpful information about connecting your  
computer. Click Next when your connection is complete.  
Shadow Logging  
Shadow Logging is a failsafe background program in the FlashLink Data Logger  
that collects data at a 30 minute interval. It is active when in Manual Start  
Waiting mode. It will record 80 days of data.  
When the logger is manually started it reverts to the programmed conditions and  
shadow data is erased from the memory.  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Time Zone Map  
Time zone information is based on Greenwich Mean Time (GMT), also known  
as Coordinated Universal Time. The field will accept decimals for those areas  
with fractional time zones.  
1. Choose either “Shipper” or “Receiver” classification for the time zone of  
your data, graphs, printouts, etc.  
2. Select or enter the time zone; the “Data Time Zones” field will accept  
decimals for those areas with fractional time zones.  
3. Click Next.  
Use the pull down menu to  
select your Data Zones.  
The value may also be  
typed in.  
OR  
Move the reference line  
over your geographic area  
and click to set your data  
zone’s “distance” from the  
GMT reference line.  
Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data Tag Information  
1. Enter the data tag information. It can be edited later, if desired.  
2. Click Next to start the download.  
Note: The Receiver field must be filled in before downloading will start unless  
the “One Click Download” option is selected in the “Customize” screen. Using  
the One Click Download option will skip both the Time Zone Map and the Data  
Tag screens and go directly to the Data screen.  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Downloading  
The data will immediately download.  
Menu Bar  
See page 19.  
Icon Bar  
See page 21.  
Click on the  
Data Info or  
Statistics tabs  
to access the  
other pages  
of the  
Information  
Panel.  
Data Grid – Use the scroll bar to  
move up or down through the  
downloaded data.  
Select Options, Statistics Range,  
then click on desired beginning  
and ending sequence numbers, or  
enter the sequence numbers in  
the FROM and TO boxes.  
Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menu Bar  
File  
View  
Options  
Open  
Open an existing data  
file on the computer.  
Download Data  
Download another  
FlashLink Data  
Logger.  
Statistics Range  
Select and change the  
statistical range in the  
Statistics Information  
Panel. Type the  
Sequence # in the  
“From” and “To”  
boxes, or click on two  
data points in the table.  
Note: Statistics  
Save…  
Update the backup file  
of the displayed data.  
Note: You can only  
update or modify after  
downloading the Data  
Tag information. The  
Data Info and Statistics  
cannot be modified.  
Graph Data  
Show downloaded  
data in a graph.  
Maximum  
Locate the highest  
value in the selected  
statistical range.  
calculation affects only  
the data points within  
the statistical range!  
Minimum  
Save As  
Locate the lowest  
value in the selected  
statistical range.  
Save the backup file  
under a new name or  
location.  
Save as Text  
Current Status  
Save all downloaded  
data and information as  
an ASCII text file.  
View the status of a  
data logger without  
interrupting the data  
logging process.  
Save as Delimited  
Creates a text delimited  
file for opening into an  
Excel or Access  
program.  
(Continued)  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
File  
Delete  
View  
Options  
The file currently open  
will be permanently  
removed from your hard  
drive.  
Email  
Proceed to page 27.  
Close  
Close the current  
screen.  
Printer SetUp  
Open the printer setup  
screen.  
Print, Selection  
Print a selected range of  
data points.  
Print, Report Page  
Print the Data Summary  
Report Page.  
Exit  
Terminate and leave the  
In-Transit FlashLink  
Software program.  
Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Icon Bar  
Same as File, Save  
Same as View,  
Maximum  
Same as File, Print,  
Print Selection  
Same as View,  
Minimum  
Same as View, Graph  
Data  
Email data  
Open a previously saved  
data file on the  
computer  
Download data from the  
data logger  
View current status of  
data logger  
Software version  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Graphs and Reports  
Graphs  
1. After downloading a data logger or opening an existing data file, report and  
graph windows appear.  
* If no graph appears, select View, Graph Data or click on the icon.  
Use the arrow keys to move the sequence marker. Information about the individual data points  
will be displayed in the Help Line if Options, Show Sequence Marker is turned on.  
Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menu Bar  
Edit  
Zoom  
Options,  
Copy as Full Color  
MetaFile  
Zoom In  
Axes, Axes  
Select the font(s).  
Click and drag your  
mouse over the area  
you want to zoom in  
on. You can  
continue zooming in  
to see details.  
16 Bit Color Clipboard  
File. Most Colors,  
Largest Size File.  
Axes, Grid  
Select colors for the  
graph, turn gridlines off  
or on, select gridline  
colors.  
Copy as Color  
MetaFile  
Restore  
256 Color Clipboard  
File. Fewer Colors,  
Medium Size File.  
(Recommended)  
Axes, Scale  
Return to the  
original full graph  
view.  
Use Manual Scaling to  
limit the time scale of  
the graph and turn  
rounding on or off.  
Select 8 HR Period  
View the graph in  
8 hour segments.  
Copy as BW MetaFile  
Axes, Ticks  
Adjust the tick marks in  
the graph.  
Black & White  
Clipboard File. Smallest  
Size  
Lines+Text,  
Lines  
Copy as Bitmap  
Copies image from  
display. Quality, Size  
and Colors Dependent  
on Display Driver.  
Select data indicator line  
styles and colors.  
Text  
Enter Axis labels, title  
and select font.  
Font Color  
Select font color.  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Edit  
Zoom  
Options,  
Hide Sequence  
Marker  
9 Show Sequence Marker  
Shown on page 23.  
Customizing a Graph’s Appearance:  
Reports  
1. After downloading a data logger or opening an existing data file.  
2. Select File, Print Report Page to print the data and the information found on  
the Data Tag, Data Info, and Statistics panels on the Download Screen.  
3. Select File, Print Selection if you want to select a specific range of data  
points.  
Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Current Status Screen  
The Current Status Screen allows you to check a data logger’s status without  
disturbing the operation. If the logging interval is 20 seconds or less, the time  
data will be off by one second.  
Select File, View Current Status, or click on the icon  
.
Asterisks (***)  
indicate a feature  
is disabled.  
For Setup Status  
Logger Messages  
see page 32  
Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Email  
You can send a file attached to an email message without leaving the FlashLink  
Program Manager program if you have access to the internet. You can also  
attach a data file using your own email program.  
Before you can email a file from within the FlashLink Program Manager you  
will be asked to enter in your Mail Account Information. If you do not have this  
information you should contact your Internet provider or your IT department.  
Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED INDICATORS  
LED ACTIVITY  
WHAT IT MEANS  
Data logger activated  
Logging  
3 green flashes:  
1 green flash every  
12 seconds:  
1 red flash every  
12 seconds:  
Alarm limits exceeded, logging continues  
Manual Start waiting or logging completed  
No flashing  
Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERROR AND WARNING MESSAGES  
ERROR AND  
WARNING MESSAGES  
WHAT THEY MEAN  
The data logger will not communicate.  
This might be a sign of a serious internal  
hardware problem. Contact  
Corrupted Configuration  
Data  
DeltaTRAK, Inc., Technical Support for  
further assistance.  
The data logger will not communicate.  
This might be a sign of a serious internal  
hardware problem. Contact DeltaTRAK,  
Inc. Technical Support for further  
assistance.  
EEPROM Failure!  
Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERROR AND  
WARNING MESSAGES  
WHAT THEY MEAN  
This message appears when there is no  
connection between PC and the data  
logger.  
FlashLink Not Accessible!  
Check for good contact between the data  
logger, cable, and computer.  
Use only a 25-pin “male-female” extension  
cable  
Check the parallel port settings on your  
computer.  
Note: Only the following parallel port  
settings are recognized. Search order is-  
Basic configuration 0000 = 0378-037F  
Basic configuration 0001 = 03BC-03BF  
Basic configuration 0002 = 0278-027F  
If you continue receiving this message,  
contact DeltaTRAK, Inc. Technical  
Support for further assistance.  
This message appears when you try to  
download the data logger and logging  
hasn’t started or no data points are  
recorded. This also occurs if the data  
logger is waiting for manual start.  
No Available Data!  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERROR AND  
WARNING MESSAGES  
WHAT THEY MEAN  
This message follows critical errors to let  
you know the download was not  
completed.  
Process not Completed!  
Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Current Status Logger Messages  
MESSAGE  
WHAT THEY MEAN  
Logging unexpectedly stopped. Data  
may not be present.  
Logging Interruption!  
Push Manual Start switch to begin  
logging.  
Invalid program conditions. Check PC  
clock setting and download.  
Manual Start Waiting!  
Startup Failure!  
Manual Start not activated. Only  
*Shadow Data may be present.  
Only *Shadow Data is present.  
*Shadow Logging Finished!  
*See page 15  
Manual Start Waiting!  
*Shadow Logging…  
Data Downloaded,  
Logging Stopped  
Data Complete!  
Data is available. Logger has  
discontinued logging data.  
The programmed conditions are  
complete. Data is available for  
downloading.  
Logging Finished!  
The programmed conditions are in  
process.  
Logging…  
Download PC, Time or Time Zone may  
be incorrect. Number of samples does  
not match current time.  
Logging Failure!  
Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
1) Software Installation Problems  
a) Make sure the FlashLink Data Logger is not connected to the PC.  
b) Close all applications and shut down the PC completely. Restart the  
computer* and install the software again.  
c) If you are still experiencing problems installing the software contact  
DeltaTRAK Inc., Technical Support for assistance.  
2) FlashLink Communication Problems  
a) Always start the In-Transit FlashLink Software before connecting the  
FlashLink Data Logger.  
b) Verify that the FlashLink Data Logger and the data cable, or the  
FlashLink Data Logger and PC parallel port (i.e. if directly connected)  
are firmly connected. Click on the Current Status icon to check the  
connection.  
c) Replace the data cable that connects the FlashLink Data Logger to the  
PC parallel port. Click on the Current Status icon to check the  
connection.  
d) Disconnect the FlashLink Data Logger and restart the PC*. Start the In-  
Transit FlashLink Software, reconnect the FlashLink Data Logger and  
click on Current Status icon.  
e) If you are still experiencing problems establishing communication  
contact DeltaTRAK Inc., Technical Support for assistance.  
* If problems persist, push “Ctrl + Alt + Delete” keys at the same time once  
and “End Task” on all programs in list except “systray” and “explorer” then  
retry.  
Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDICES  
Product Specifications  
Instrument  
Operating Range:  
-40°F~150°F (-40C°~66°C)  
-112°F~230°F (-80°C~110°C)  
Ext. Probe Cable:  
Temperature Resolution: 0.1°F or °C  
Logged Data Capacity:  
Two LED indicators:  
Battery Type / Life:  
Enclosure:  
3,800 data points  
12 second flashing red for alarm / green for logging  
18 months with typical use  
ABS plastic case construction  
Drop from 3 feet to hard surface  
TÜV – CE Mark  
Shock Resistance:  
Certification:  
Probes/ Sensors  
Internal Sensor Range:  
External Probe Range:  
-40°F~150°F (-40C°~66°C)  
-112°F~230°F (-80C°~110°C) Low Range  
Ext. Probe Stabilization: 15 seconds in moving fluid, for a step change of temperature  
of 50°F / 25°C  
Temp. Accuracy:  
+ 1°F (.5°C) at 32°F~150°F (0°C~66°C)  
+ 2°F (1°C over entire range  
Software  
Data Download Time:  
5 seconds typical for 3,800 data points  
Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In-Transit FlashLink Data Logger Models Available  
Model # Description  
20011  
20012  
20013  
20014  
20041  
20042  
20043  
05-Day In-Transit Temperature Logger  
15-Day In-Transit Temperature Logger  
45-Day In-Transit Temperature Logger  
75-Day In-Transit Temperature Logger  
05-Day In-Transit External Temperature Blunt Probe -80°C  
15-Day In-Transit External Temperature Blunt Probe -80°C  
45-Day In-Transit External Temperature Blunt Probe -80°C  
Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Compatibility  
The following laptop computers have been tested for compatibility with the  
FlashLink Data Logger and In-Transit FlashLink Software:  
Chicony NP Series  
IBM ThinkPad  
Compaq Armada Series  
CTX EZ Book  
NEC Versa Series  
Toshiba Satellite Series  
Sony VAIO Series  
Hewlett Packard Omnibook  
Contact DeltaTRAK for the latest compatibility information  
Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Additional Connection Options  
Add a PC card with a dual parallel port.  
o
SIIG Inc. Model 101828 allows the FlashLink Data Logger to  
function simultaneously with your printer.  
Add a data switch with a 25 pin parallel port to manually switch  
between the FlashLink Data Logger and the printer.  
o
Belkin Components, Precision Instruments  
Add a Port Buffer to increase data logger download speed, compensate  
for a weak printer port, low battery, or low quality cable.  
o
DeltaTRAK  
Add a Data switch with port buffer to get functionality of both the data  
switch and port buffer combined.  
o
DeltaTRAK  
Add the Serial Port Adapter model # 20218  
DeltaTRAK  
o
Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
DeltaTRAK instruments have a limited warranty period of 1 year against defects  
in materials and workmanship from the date of purchase. Accessory items and  
sensors have a limited warranty of 3 months. DeltaTRAK, Inc. shall, at its  
option, either repair or replace hardware products that prove to be defective, if a  
notice to that effect is received within the warranty period. DeltaTRAK, Inc.  
makes no other warranties or representations of any kind whatsoever, expressed  
or implied, except that of title, and all implied warranties including any warranty  
of merchantability and fitness for a particular purpose are hereby disclaimed.  
Limitation of Liability  
The remedies of purchases set forth herein are exclusive and the total liability of  
DeltaTRAK, Inc. with respect to this order, whether based on contract, warranty,  
negligence, indemnification, strict liability or otherwise, shall not exceed the  
purchase price of the product upon which liability is based. In no event shall  
DeltaTRAK, Inc. be liable for consequential, incidental, or special damages.  
Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contacting DeltaTRAK, Inc.  
Post Trip Calibration and Technical Support  
DeltaTRAK Technologies  
9260 Isaac Street, Suite D  
Santee, CA 92071  
Phone: (619) 596-4830  
Toll Free: (800) 390-0804  
Fax: (619) 596-4829  
Customer Service  
DeltaTRAK, Inc.  
P.O. Box 398  
Pleasanton, CA 94566  
Phone: (925) 249-2250  
Toll Free: (800) 962-6776  
Fax: (925) 249-2251  
Website  
FlashLinkand DeltaTRAKare registered trademarks  
2004 DeltaTRAK, Inc. All rights reserved.  
Version : April 09, 2004  
Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Blu ray Player BD HP25U User Manual
Sony CD Player 480p User Manual
Star Micronics Printer NB24 10 15 User Manual
Sterling Plumbing Indoor Furnishings 11409 User Manual
Sub Zero Refrigerator IT 36R User Manual
Sunbeam Toaster 6165 33 User Manual
Sunpentown Intl Food Processor SO 2000 User Manual
Sylvania CRT Television 6319CCB User Manual
Tanaka Trimmer TPH 210 User Manual
Tannoy Speaker B225 User Manual