Seiko Watch Y182 User Guide

You are now the proud owner of a SEIKO Analogue Quartz Watch Cal.  
Y182. For best results, please read the instructions in this booklet  
carefully before using your SEIKO Analogue Quartz Watch. Please keep  
this manual handy for ready reference.  
Siete ora in possesso di un orologio SEIKO Analogico al Quarzo Cal. Y182.  
Per ottenere i migliori possibili risultati dal vostro orologio, leggere  
attentamente le istruzioni di questo manuale prima di utilizzare il vostro  
orologio SEIKO analogico al quarzo. Conservare poi il manuale stesso per  
ogni qualsiasi eventuale futuro riferimento.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEIKO ANALOGUE QUARTZ  
Cal. Y182  
FEATURES  
TIME/CALENDAR  
STOPWATCH  
Hour & minute hands with small  
second hand  
Measures up to 30 minutes in 1/5  
second increments.  
Date displayed in numerals  
Can measure repeatedly up to 6  
hours.  
TACHYMETER  
ALARM  
For models with tachymeter scale  
Can be set on a 12-hour basis  
with small alarm hands.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
DISPLAY AND CROWNS/BUTTONS  
There are three buttons and two crowns.  
STOPWATCH minute hand  
STOPWATCH 1/5 second hand  
Minute hand  
(MAIN TIME)  
B
30  
A
Hour hand  
(MAIN TIME)  
a b  
c
CROWN 1  
12  
Second hand  
(MAIN TIME)  
ALARM  
6
Date  
a
b
c
C
CROWN 2  
ALARM hour hand  
ALARM minute hand  
a: Normal position  
b: First click  
c: Second click  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
DATE SETTING  
Date  
CROWN 1  
1
1
2
Pull out to first click.  
1
2
Turn clockwise until the date for  
the previous day appears.  
CROWN 1  
3
Pull out to second click and turn  
until the desired date appears.  
3
4
Push back in to normal position.  
4
NOTES  
1
Do not set the date between 9:00 p.m. and 3:00 a.m. Otherwise, the date may not  
change properly.  
* If it is necessary to set the date during that time period, first change the time to any time outside  
this period, set the date and then reset the correct time.  
2
It is necessary to adjust the date at the end of February and 30-day months.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
TIME SETTING  
CROWN 1  
Minute hand  
Hour hand  
1
Pull out to second click when  
Second hand is at the 12 o’clock  
1
position.  
60  
30  
2
2
Turn to set Hour and Minute  
hands.  
3
3
Push back in to normal position  
in accordance with a time signal.  
CROWN 1  
Second hand  
NOTES  
1
When setting Hour hand, check that AM/PM is correctly set.  
* The watch is so designed that the date changes once in 24 hours. Turn the hands past the 12  
o’clock marker to determine whether the watch is set for the A.M. or P.M. period. If the date  
changes, the time is set for the A.M. period. If the date does not change, the time is set for  
the P.M. period.  
2
When setting Minute hand, advance it 4 to 5 minutes ahead of the desired time and  
then turn it back to the exact minute.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
ALARM  
Alarm time is set on a 12-hour basis.  
ALARM hands move independently of MAIN TIME hands.  
ALARM SETTING  
1
Adjustment of ALARM hands  
After the main time is adjusted, follow the procedure below, and then set the  
alarm.  
* The following procedure is necessary only after the main time is adjusted.  
Hour hand  
(MAIN TIME)  
Minute hand  
(MAIN TIME)  
CROWN 2  
1
Pull out to second click.  
ALARM  
minute hand  
2
Turn clockwise or counterclockwise  
to set ALARM hands to the current  
time (MAIN TIME).  
12  
1
ALARM  
6
ALARM  
hour hand  
3
Push back in to normal position.  
CROWN 2  
3
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
2
Alarm time setting  
* Once ALARM hands are adjusted to the main time, alarm time setting can be made only by  
following the procedure below.  
Pull out to first click.  
CROWN 2  
Press to set ALARM hands to  
the desired alarm time.  
C
12  
Push back in to normal posi-  
tion.  
ALARM  
6
CROWN 2  
C
CROWN 2  
NOTES  
1
When setting ALARM minute hand to the current time in 2 , advance it 4 to 5  
minutes ahead of the desired time and then turn it back to the exact minute.  
2
3
Alarm hands move quickly if Button C is kept pressed.  
If CROWN 2 is pulled out to first click within 1 minute after being pushed back in  
to normal position in 3 , the alarm sounds.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
ALARM ENGAGEMENT/DISENGAGEMENT  
Alarm engagement  
Alarm disengagement  
Push back in to normal  
position.  
Pull out to first click.  
CROWN 2  
CROWN 2  
12  
12  
1
11  
2
10  
ALARM  
6
ALARM  
8
Designated  
alarm time  
Current time  
7
5
6
[Alarm engaged]  
[Alarm disengaged]  
NOTES  
1
Alarm rings at the designated time for 20 seconds.  
* To stop it manually, press Button A, B or C, or push CROWN 2 back in to normal position.  
2
If CROWN 2 is pulled out to second click, the designated alarm time is canceled  
with a warning beep.  
* In that case, set ALARM hands to MAIN TIME again, push CROWN 2 back in to normal position,  
and then, pull it out to first click and set the desired alarm time again. However, if CROWN 2  
is pushed back in to normal position before the warning beep stops, the designated alarm time  
will not be canceled.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
STOPWATCH  
Stopwatch measures up to 30 minutes in 1/5 second increments.  
After 30 minutes, it will start counting again from “0” repeatedly up to 6 hours.  
STOPWATCH OPERATION  
STOPWATCH  
minute hand  
30  
Before using the stopwatch:  
B
A
Check that CROWNS 1 and 2  
are set at normal position.  
Press Button B to reset STOP-  
WATCH hands to “0” position.  
MIN.  
CROWN 1  
* If the hands do not return to “0”  
position, follow the procedure in  
“ADJUSTING THE HAND POSI-  
TION” (page 15).  
CROWN 2  
STOPWATCH  
1/5 second hand  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
1 Standard measurement  
B
A
A
START  
A
STOP  
B
RESET  
2 Accumulated elapsed time measurement  
A
START  
A
STOP  
A
A
STOP  
B
RESET  
RESTART  
* Restart and stop of stopwatch can be repeated by pressing Button A.  
3 Split time measurement  
A
START  
B
SPLIT  
B
SPLIT  
A
STOP  
B
RESET  
RELEASE  
* Measurement and release of split time can be repeated by pressing Button B.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
4 Measurement of two competitors  
A
B
B
RESET  
A
B
START  
FINISH TIME  
OF 1ST  
2ND  
FINISH TIME  
OF 2ND  
COMPETITOR  
FINISHES  
COMPETITOR  
COMPETITOR  
NOTES  
1
2
3
If CROWN 1 is pulled out to second click, STOPWATCH hands are reset to “0”  
position.  
If CROWN 2 is pulled out to first or second click, STOPWATCH hands are reset to  
“0” position.  
When stopwatch has been reset and Button A is pressed before the hands reach  
“0” position, stopwatch still starts counting when Button A is pressed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
TACHYMETER  
(for models with tachymeter scale on the dial)  
To measure the hourly average speed of a vehicle  
1
2
Use the stopwatch to determine  
how many seconds it takes to go  
1 km or 1 mile.  
Ex. 1  
30  
5
25  
STOPWATCH  
second hand:  
40 seconds  
10  
MIN.  
Tachymeter scale indicated by  
STOPWATCH second hand gives  
the average speed per hour.  
Tachymeter scale: “90”  
“90” (tachymeter scale figure) x 1 (km or mile)  
= 90 km/h or mph  
* Tachymeter scale can be used only when the time required is less than 60 seconds.  
Ex. 2: If the measuring distance is extended to 2 km or miles or shortened to 0.5 km or miles  
and STOPWATCH second hand indicates “90” on tachymeter scale:  
“90” (tachymeter scale figure) x 2 (km or mile) = 180 km/h or mph  
“90” (tachymeter scale figure) x 0.5 (km or mile) = 45 km/h or mph  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
To measure the hourly rate of operation  
Ex. 1  
1
2
Use the stopwatch to measure  
the time required to complete 1  
job.  
30  
STOPWATCH  
second hand:  
20 seconds  
MIN.  
Tachymeter scale indicated by  
STOPWATCH second hand gives  
the average number of jobs ac-  
complished per hour.  
Tachymeter scale: “180”  
“180” (tachymeter scale figure) x 1 job  
= 180 jobs/hour  
Ex. 2: If 15 jobs are completed in 20 seconds:  
“180” (tachymeter scale figure) x 15 jobs = 2700 jobs/hour  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
ADJUSTING THE HAND POSITION  
If STOPWATCH hands will not return to the 12 o’clock position when the stopwatch is  
reset or when the battery is replaced with a new one, follow the procedure below.  
CROWN 1  
Pull out to second click.  
CROWN 1  
B
A
30  
Press repeatedly to reset  
STOPWATCH minute hand to  
the 12 o’clock position.  
A
MIN.  
Press repeatedly to reset  
STOPWATCH second hand to  
the 12 o’clock position.  
B
Push back in to normal posi-  
tion.  
CROWN 1  
NOTES  
1
2
Hands move quickly if the respective buttons are kept pressed.  
After adjusting the hand position, set the main time.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
RESETTING THE BUILT-IN IC  
Incaseanyofthehandsshouldmoveimproperly, followtheprocedurebelowtoadjust  
the hand movement.  
CROWN 1  
Pull out to second click.  
CROWN 1  
B
A
30  
AND  
Press simultaneously.  
B
A
10  
MIN.  
Push back in to normal posi-  
tion.  
CROWN 1  
NOTE  
Before using the watch again, be sure to adjust the position of STOPWATCH hands and  
set the main time and alarm.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
BATTERY LIFE INDICATOR  
When the battery nears its end, the small second hand moves at two-second intervals  
insteadofnormalone-secondintervalstoindicatethatthebatteryneedstobereplaced  
with a new one.  
* If the alarm is used while the second hand is moving at two-second intervals, the watch  
maystopoperating. Therefore,ifyouseethesecondhandmovingattwo-secondintervals,  
replace the battery with a new one as soon as possible.  
BATTERY CHANGE  
The miniature battery which powers your watch should last approximately  
2 years. However, because the battery is inserted at the factory to check  
the function and performance of the watch, its actual life once in your  
possession may be less than the specified period. When the battery  
expires, be sure to replace it as soon as possible to prevent any malfunction.  
For battery replacement, we recommend that you contact an AUTHORIZED  
SEIKO DEALER and request SEIKO SR927W battery.  
2
Years  
WARNING  
Do not remove the battery from the watch.  
If it is necessary to take out the battery, keep it out of the reach of children. If  
a child swallows it, consult a doctor immediately.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
CAUTION  
Never short-circuit, heat or otherwise tamper with the battery, and never  
expose it to fire. The battery may burst, become very hot or catch fire.  
The battery is not rechargeable. Never attempt to recharge it, as this may cause  
battery leakage or damage to the battery.  
SPECIFICATIONS  
1
2
Frequency of crystal oscillator ...........  
32,768 Hz (Hz = Hertz ... Cycles per second)  
Loss/gain (monthly rate) ..................... Less than 20 seconds at normal temperature range (5°C ~  
35°C) (41°F ~ 95°F)  
3
4
5
6
Accuracy of alarm ............................... ±1 minute  
Operational temperature range .......... –5°C ~ +50°C (23°F ~ 122°F)  
Driving system ...................................  
Step motor, 4 pieces  
Display system  
Time ............................................  
Three hands (Hour, minute and small second hands)  
Date ............................................. Displayed in numerals.  
Stopwatch ...................................  
Minute and 1/5 second hands  
The stopwatch can measure up to 30 minutes in 1/5 seconds.  
Alarm ........................................... Small hour and minute hands  
The alarm is set on a 12-hour basis.  
7
8
Battery ...............................................  
IC (Integrated Circuit) ......................... C-MOS-LSI  
SEIKO SR927W, 1 piece  
* The specifications are subject to change without prior notice for product improvement.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  

Raritan Computer Marine Radio CC WSAPI 0B v510 E User Guide
RCA Flat Panel Television 70 T19931 310 User Guide
RCA Microwave Oven RMW991 User Guide
RedMax Trimmer BC2601DL User Guide
Reebok Fitness Treadmill RBTL59110 User Guide
Renesas Computer Hardware M32176T PTC User Guide
RIDGID Drill R7111 User Guide
Roper Clothes Dryer 3405639A User Guide
RoyalTek GPS Receiver REB 1315LPNX User Guide
Ryobi Lawn Mower 136 User Guide