Cal. 5J22, 5J32
INSTRUCTIONS
(P. 3)
(S. 17)
(P. 32)
(P. 46)
(P. 61)
(P. 75)
(89 ¯)
BEDIENUNGSANLEITUNG
INSTRUCTIONS
ISTRUZIONI
INSTRUCCIONES
INSTRUÇÕES
p @
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
Page
FEATURES ..................................................................................................................
POWER SAVE FUNCTION ..........................................................................................
TIME RELAY FUNCTION ............................................................................................
HOW TO SET THE TIME AND DATE..........................................................................
ENERGY DEPLETION FOREWARNING FUNCTION ...................................................
POWER RESERVE IN YOUR SEIKO KINETIC WATCH ...............................................
REMARKS ON THE KINETIC E.S.U. ...........................................................................
ROTATING BEZEL ......................................................................................................
SPECIFICATIONS........................................................................................................
4
5
7
10
12
13
14
15
16
✩ For the care of your watch, see “TO PRESERVE THE QUALITY OF YOUR
WATCH” in the attached Worldwide Guarantee and Instruction Booklet.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
FEATURES
SEIKO KINETIC AUTO RELAY Cal. 5J22/5J32 is an analogue quartz watch equipped with an
Automatic Generating System developed by SEIKO. It generates the electric energy to power
the watch, utilizing the movement of the arm, and stores it in the KINETIC ELECTRICITY
STORAGE UNIT (KINETIC E.S.U.), which requires no periodical replacement unlike conventional
button-type batteries.
Cal. 5J22/5J32 is an enhanced model of the KINETIC watches and features the power save and
time relay functions to keep the watch operating for up to four years once it is fully charged,
even if it is left unused and no charging is done.
I Power save function
If the watch is left unused for 3 days, the
hands stop automatically to conserve the
stored electric energy.
I Time relay function
Though the hands stop, the built-
in IC continues to keep the time.
To use the watch again, swinging
it several times will awaken it.
The hands will move quickly to
➡
indicate the current time, and
resume normal operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
POWER SAVE FUNCTION
G If the watch is left untouched for approximately 3 days (72 hours), the hands will stop
moving to minimize the electrical energy consumed.
G Though the hands stop while the power save function is in operation, the built-in IC
continues to compute the correct time.
G More specifically, the watch measures the time during which the generating system
remains inactive and no charging is done. The power save function is activated when such
time period extends to approximately 72 hours without a break. If the watch senses
movement of the oscillating weight before the completion of 72 hours, the measurement
of the inactive time is stopped and reset to “0”.
G If the watch is kept in a situation where movement repeatedly causes the hands to keep
moving and the power save function is prevented from being activated without additional
charge, the energy will be consumed in approximately 6 months after the watch is fully
charged.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Manual power save function
The power save function can be activated manually. If you decide not to use the watch
for a long time, use this function to further conserve energy.
* While the second hand is moving at two-second intervals, the power save function cannot be
activated manually. In this case, charge the watch referring to “ENERGY DEPLETION FOREWARNING
FUNCTION”, and then, follow the procedure below.
CROWN
Pull out to the first click.
➠
* Pull out and push in within one second.
M
Push in to the normal position.
➠
* The hands will stop as the power save function
is activated.
Note: If your watch has a screw lock type crown, turn the crown counterclockwise to unscrew it, and
then, pull it out. After using the crown, push it back in to the normal position, and then, turn it
clockwise to screw it in completely.
Caution:
Do not pull out the crown to the second click while the power save function is in
operation. Otherwise, it is turned off, and the time data retained inside the watch
will be erased, thus disabling the time relay function.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
TIME RELAY FUNCTION
G While the power save function is working, the built-in IC continues to compute the time
though the hands have stopped. As a certain amount of electricity is generated by swinging
the watch, the time relay function is activated, and the hands are adjusted automatically to
the time retained inside the watch.
G If the watch is charged fully as the power save function is activated, the time relay function
remains operable for approximately four years.
* The time period varies depending on the amount of power reserve stored in the KINETIC E.S.U.
How to activate the time relay function
Caution:
Do not pull out the crown to the second click before activating the time relay
function. Otherwise, the time data retained inside the watch will be erased,
thus disabling the time relay function.
G Swing the watch from side to side for 2 to 3 seconds.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
1. The hour and minute hands move quickly to indicate the
current time computed by the IC, setting AM and PM
properly.
2. The second hand moves quickly to indicate the current
second, and then continues moving at one-second intervals.
Notes:
1. Swing the watch from side to side, making an arc of about 20 cm. Swing 4 to 6 times at a rate
of twice a second.
2. No additional benefit is obtained by swinging the watch longer or with greater vigor.
3. When the watch is swung, the oscillating weight in the generating system rotates to drive the
mechanism. As it rotates, it gives out a sound, which is not a malfunction.
G Remarks on using the time relay function
1. When using the watch for the first time after it is purchased, it is necessary to adjust the
time and date as the watch has been adjusted to the time of the area where SEIKO’s
factory is located.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
2. The built-in IC computes the time in the 24-hour indication, making a distinction between
AM and PM periods. It does not compute the date, and the time relay function will not
adjust the date. If the power save function has been active for more than 1 day before the
time relay function is activated, be sure to adjust the date to the current date.
3. If the power save function has been in operation for several months before the time relay
function is activated, the time indicated by the hands may include a certain amount of
time loss or gain that has accumulated during those months. Adjust the hands as
required.
4. If the power reserve decreases to an extremely low level while the power save function
is in operation, the time relay function may not be activated by swinging the watch.
Instead, the second hand starts moving at two-second intervals. In this case, set the time
manually, and charge the watch referring to “ENERGY DEPLETION FOREWARNING
FUNCTION”.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
HOW TO SET THE TIME AND DATE
1. Pull out the crown to the first click and turn
it counterclockwise to set the previous day’s
date.
2. Pull out the crown to the second click when
the second hand is at the 12 o’clock position,
and advance the hands by turning the crown
counterclockwise to set the desired date.
➠ ➠
➠
3. Turn the hands to set the desired time.
4. Push back the crown completely in
accordance with a time signal.
Notes:
1. If your watch has a screw lock type crown, turn the crown counterclockwise to unscrew it, and then,
pull it out. After using the crown, push it back in to the normal position, and then, turn it clockwise
to screw it in completely.
2. Do not set the date between 9:00 p.m. and 1:00 a.m. Otherwise, it may not change properly. If
it is necessary to set the date during that time period, first change the time to any time outside it,
set the date and then reset the correct time.
3. When setting the time, make sure that the second hand is moving at one-second intervals.
4. When setting the hour hand, check that AM/PM is correctly set. The watch is so designed that the
date changes once in 24 hours.
Turn the hands past the 12 o’clock marker to determine whether the watch is set for the A.M.
or P.M. period. If the date changes, the time is set for the A.M. period. If the date does not
Download from Www.Somanuals.com. All Manuals Search And Download.
10
change, the time is set for the P.M. period.
5. When setting the minute hand, advance it 4 to 5 minutes ahead of the desired time and then turn
it back to the exact minute.
6. It is necessary to adjust the date at the end of February and 30-day months. In this case, pull out
the crown to the first click and turn it until the desired date appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
ENERGY DEPLETION FOREWARNING FUNCTION
The watch has been charged fully at the factory, and the power save function will keep
the built-in IC computing the time for up to four years. Normally, therefore, it is not
necessary to charge the watch manually by swinging it. If you should find the second
hand moving at two-second intervals, however, charge the watch following the
procedure in “G How to charge the watch”.
G When the second hand starts moving at two-second intervals instead of the normal one-
second intervals, the watch will run down in approximately 12 hours.
G If the second hand starts moving at two-second intervals when the power save function is
turned off by swinging the watch, the power reserve may have become depleted to an
extremely low level.
In those cases, charge the watch following the procedure below.
G How to charge the watch
1. Swing the watch from side to side approximately 500 times.
* Swing rhythmically at a rate of twice a second.
* If the second hand still moves at two-second intervals after the watch is
swung 500 times, swing it further until the second hand moves at one-
second intervals.
2. Swing the watch approximately 200 times further to reserve
one day of power.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
* It is not necessary to charge the watch fully, as it is charged automatically
while it is worn on your wrist.
Notes:
1. To charge the watch efficiently, swing the watch from side to side, making an arc of about 20 cm.
2. No additional benefit is obtained by swinging the watch more quickly or with greater vigor.
3. When the watch is swung, the oscillating weight in the generating system rotates to drive the
mechanism. As it rotates, it gives out a sound, which is not a malfunction.
4. The watch is equipped with a system to prevent overcharge. Even if it is further swung after being
fully charged, no malfunction will result.
5. Wear the watch daily for at least 10 hours.
6. Even if the watch is worn on your arm, it will not be charged while your arm is not in motion.
POWER RESERVE IN YOUR SEIKO KINETIC WATCH
G The electric energy generated while the watch is worn on your wrist is stored in the KINETIC
E.S.U. It is a power source completely different from conventional batteries for watches and
does not require any periodical replacement.
G Power reserve guideline for the KINETIC E.S.U.
• You can estimate the power reserve accumulated in the KINETIC E.S.U. from the manner
in which you wear the watch.
• Using the manual power save function as often as possible is an effective way to conserve
the power reserve.
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Wearing the watch continuously for 12 hours will accumulate approximately one and a
half additional days of power reserve.
If you wear the watch every day for 12 hours over a period of a week, approximately 10
days of power reserve will be secured in the KINETIC E.S.U., which will keep the watch
operating for approximately 2 months when the hands are stopped by the power save
function.
G Precautions for those only wearing the watch occasionally
If you use the watch only occasionally, it is likely that, when you decide to use it, you will find
the hands have stopped and the power save function has been activated. Before wearing
the watch, be sure to use the time relay function to awaken the watch following the
procedure in “How to activate the time relay function”.
* To use the power reserve more efficiently, it is recommended that the manual power save function be
used as often as possible when you remove the watch from your wrist.
REMARKS ON THE KINETIC E.S.U.
G Precaution
Do not pull the crown out to the second click to stop the hands with the intention of saving
the energy stored in the KINETIC E.S.U. By doing so, a large amount of current flows through
the built-in IC, and therefore, pulling out the crown will not save energy but actually consume
more energy than usual. Instead, use the manual power save function to conserve the power
reserve.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
CAUTION
Never install a silver oxide battery for conventional watches in place of the KINETIC
E.S.U. The battery may burst, become very hot or catch fire.
ROTATING BEZEL (for models with rotating bezel)
G The rotating bezel can show up to 60 minutes of elapsed time.
1. Turn the rotating bezel to align its “
mark with the minute hand.
”
Start
2. Read the number on the rotating bezel that
the minute hand points to.
Elapsed
time
30 minutes
have elapsed.
Note: For some models, the rotating bezel rotates only counterclockwise.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
SPECIFICATIONS
1
Frequency of crystal oscillator ................... 32,768 Hz (Hz = Hertz … Cycles per second)
2
Loss/gain (Monthly rate) ............................ Less than 15 seconds at normal temperature range (5° C
~ 35° C) (41° F ~ 95° F)
3
4
Operational temperature range .................. –10° C ~ +60° C (14° F ~ 140° F)
Display system
Time ........................................................ Hour, minute and second hands
Date ........................................................ Displayed in numerals
Driving system ........................................... Step motor, 2 pieces
5
6
Duration of charge
Validity of time relay function ................. Approximately 4 years (Full charge)
After the second hand starts
moving at two-second intervals .............. Approximately 12 hours
7
Additional function ..................................... Power save function, manual power save function, energy
depletion forewarning function and overcharge prevention
function
8
9
IC (Integrated Circuit) ................................. C-MOS-IC, 2 pieces
Generating system ..................................... Miniature AC generator
10 KINETIC ELECTRICITY STORAGE UNIT .... Button type, 1 piece
*
The specifications are subject to change without prior notice for product improvement.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
|