Sears Water Heater 153336162 User Guide

Owner’s Manual  
POWER MISER™ 6  
GAS WATER HEATER  
FOR POTABLE WATER HEATING ONLY.  
NOT SUITABLE FOR SPACE HEATING.  
NOT FOR USE IN MOBILE HOMES.  
MODEL NO.  
153.336162  
153.336262  
153.336362  
153.336466  
153.336566  
153.336762  
153.336862  
153.336962  
30 Gallon Short  
40 Gallon Short  
30 Gallon  
40 Gallon  
50 Gallon  
30 Gallon Propane (L.P.)  
40 Gallon Propane (L.P.)  
50 Gallon Propane (L.P.)  
• Safety Instructions  
• Installation  
• Operation  
• Care and Maintenance  
• Troubleshooting  
• Parts List  
For Your Safety  
AN ODORANTISADDEDTOTHE GAS USED BYTHIS WATER HEATER.  
C3 Technology® Gas Water Heaters meet  
the new ANSI Z21.10.1 standard that deals  
with the accidental or unintended ignition  
of flammable vapors, such as those  
emitted by gasoline.  
ADVERTENCIA  
Si no puede leer o entender el inglés y necesita el manual instructivo  
y/o etiquetas en español puede obtenerlos llamando al  
1-800-821-2017. NO TRATE DE INSTALAR O OPERAR ESTE  
CALENTADOR DEAGUAsi no entiende la información en las etiquetas  
o en el manual instructivo. No hacer caso de esta advertencia podría  
resultarenlaMUERTEOGRAVESLESIONESCORPORALES.  
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A  
www.sears.com  
PRINTED IN THE U.S.A 0705  
PART NO. 184231-001  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY PRECAUTIONS  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SAFE INSTALLATION, USEAND SERVICE ................................................................................................. 2  
SAFETY PRECAUTIONS.............................................................................................................................. 3  
TABLE OF CONTENTS ................................................................................................................................ 4  
CUSTOMER RESPONSIBILITIES ................................................................................................................ 5  
PRODUCT SPECIFICATIONS...................................................................................................................... 5  
MATERIALS AND BASIC TOOLS NEEDED ................................................................................................. 6  
Material Needed ...................................................................................................................................................... 6  
Basic Tools ............................................................................................................................................................. 6  
TYPICAL INSTALLATION............................................................................................................................... 7  
INSTALLATION INSTRUCTIONS...............................................................................................................8-16  
Removing the Old Water Heater .............................................................................................................................. 8  
Facts to Consider About the Location ................................................................................................................ 9-10  
Insulation Jackets ................................................................................................................................................. 10  
CombustionAir and VentilationAppliances  
in Unconfined Spaces............................................................................................................................................ 10  
CombustionAir and VentilationAppliances  
in Confined Spaces ...........................................................................................................................................11-12  
Water Piping .................................................................................................................................................... 12-13  
Temperature Pressure Relief Valve.................................................................................................................... 13-14  
Filling the Water Heater......................................................................................................................................... 14  
Venting ............................................................................................................................................................. 14-15  
Gas Piping ....................................................................................................................................................... 15-16  
Sediment Trap .................................................................................................................................................. 16-17  
OPERATING INSTRUCTIONS ................................................................................................................ 18-19  
Lighting & Operating Label .................................................................................................................................... 18  
Temperature Regulation ......................................................................................................................................... 19  
SERVICE AND ADJUSTMENT ............................................................................................................... 20-22  
Tank (Sediment) Cleaning ...................................................................................................................................... 20  
Venting System Inspection .................................................................................................................................... 20  
Burner Inspection .................................................................................................................................................. 20  
Burner Cleaning ..................................................................................................................................................... 20  
Housekeeping .................................................................................................................................................. 20-21  
Anode Rod Inspection ........................................................................................................................................... 21  
Temperature-Pressure Relief Valve Operation ........................................................................................................ 21  
Draining ............................................................................................................................................................ 21-22  
Drain Valve Washer Replacement.......................................................................................................................... 22  
Service .................................................................................................................................................................. 22  
TROUBLESHOOTING GUIDE ................................................................................................................ 23-26  
Start Up Conditions .............................................................................................................................................................23-25  
Thermal Expansion........................................................................................................................................... 23  
Strange Sounds ............................................................................................................................................... 23  
Draft Hood Operation ................................................................................................................................... 23-24  
Condensation ................................................................................................................................................... 24  
Smoke/Odor ..................................................................................................................................................... 24  
Operational Conditions ..................................................................................................................................... 24-25  
Smelly Odor ..................................................................................................................................................... 24  
Air in Hot Water Faucets.................................................................................................................................. 25  
HighTemperature Shut-Off System .................................................................................................................. 24  
Leakage Checkpoints ....................................................................................................................................... 25  
Troubleshooting Items ........................................................................................................................................... 26  
NOTES.................................................................................................................................................... 27-28  
PARTS ORDER LIST ............................................................................................................................. 29-31  
WARRANTY ................................................................................................................................................ 32  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CUSTOMER RESPONSIBILITIES  
The installation must conform with these instructions and  
the local code authority having jurisdiction. In the absence of  
local codes, installations shall comply with the following:  
Thank You for purchasing a Kenmore water heater. Properly  
installed and maintained, it should give you years of trouble  
free service. If you should decide that you want the new water  
heater professionally installed by Sears call 1-800-4-MY-HOME®.  
They will arrange for prompt, quality installation by Sears  
authorized contractors.  
In the United States: The National Fuel Gas Code ANSI  
Z223.1/NFPA 54. This publication is available from the  
Canadian Standards Association, 8501 East Pleasant Valley  
Rd, Cleveland Ohio 44131, or The National Fire Protection  
Association, 1 Batterymarch Park, Quincy, MA 02269.  
Abbreviations Found In This Instruction Manual:  
CSA - Canadian Standards Association  
If after reading this manual you have any questions or do not  
understand any portion of the instructions, call the Sears  
Service Center.  
ANSI - American National Standards Institute  
NFPA - National Fire Protection Association  
ASME - American Society of Mechanical Engineers  
GAMA - Gas Appliance Manufacturers Association  
Carefully plan the place where you are going to put the water  
heater. Correct combustion, vent action, and vent pipe  
installation are very important in preventing death from  
possible carbon monoxide poisoning and fires. See  
figure 1.  
This gas-fired water heater is design certified by CSA  
INTERNATIONAL under American National Standard/CSA  
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1  
(current edition).  
Examine the location to ensure the water heater complies  
with the Facts to Consider About the Location section in this  
manual.  
Read the “Safety Precautions” section, page 3 of this manual  
first and then the entire manual carefully. If you don’t follow  
the safety rules, the water heater will not operate properly. It  
could cause DEATH, SERIOUS BODILY INJURY AND/OR  
PROPERTY DAMAGE.  
For California installation this water heater must be braced,  
anchored, or strapped to avoid falling or moving during an  
earthquake. See instructions for correct installation  
procedures. Instructions may be obtained from your local  
dealer, wholesaler, public utilities or California Office of the  
State Architect, 400 P Street, Sacramento, CA 95814.  
This manual contains instructions for the installation,  
operation, and maintenance of the gas-fired water heater. It  
also contains warnings through out the manual that you must  
read and be aware of. All warnings and all instructions are  
essential to the proper operation of the water heater and  
your safety. Since we cannot put everything on the first few  
pages, READ THE ENTIRE MANUALBEFOREATTEMPTING  
TO INSTALLOR OPERATE THE WATER HEATER.  
Massachusetts Code requires this water heater to be  
installed in accordance with Massachusetts 248-CMR 2.00:  
State Plumbing Code and 248-CMR 5.00.  
Complies with SCAQMD rule #1121 and districts having  
equivalent NOx requirements.  
PRODUCT SPECIFICATIONS  
RECOVERY  
MINIMUM  
DIMENSIONS  
TANK  
CAPACITY  
IN GALS (LTRS)  
TYPE  
O F  
GAS  
INPUT RATE GALS.  
VENT PIPE  
INCHES  
(mm)  
DIAMETER IN INCHES (mm)  
MODEL  
NUMBER  
RATE  
PER HOUR  
INCHES  
(mm)  
HEIGHT TO  
JACKET TOP  
(Btu/hr) @ 90°F RISE  
153.336162  
153.336262  
153.336362  
153.336466  
153.336566  
153.336762  
153.336862  
153.336962  
30 (114)  
40 (151)  
30 (114)  
40 (151)  
50 (189)  
30 (114)  
40 (151)  
50 (189)  
NATURAL  
NATURAL  
NATURAL  
NATURAL  
NATURAL  
PROPANE  
PROPANE  
PROPANE  
32,000  
35,500  
35,500  
35,500  
35,500  
35,500  
35,500  
35,500  
30.6  
35.4  
34.9  
35.4  
35.4  
34.9  
35.4  
35.4  
3" (76) or 4" (102) 18 1/2" (470)  
43 3/4" (1,111)  
47 1/4" (1,200)  
57 1/2” (1,461)  
55 1/2" (1,410)  
56 1/2” (1,435)  
57 1/2” (1,461)  
55 1/2” (1,410)  
56 1/2” (1,435)  
3" (76) or 4" (102)  
3” (76)  
20" (508)  
16” (406)  
3" (76)  
18 1/2" (470)  
20" (508)  
3" (76)  
3" (76)  
16" (406)  
3" (76)  
18 1/2" (470)  
20" (508)  
3" (76)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
MATERIALS AND BASIC TOOLS NEEDED  
Materials Needed  
To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials,  
depending on your type of installation.  
DRAIN PANS AVAILABLE IN 20”  
EXPANSION TANKS FOR  
THERMAL EXPANSION  
CONDITIONS AVAILABLE  
IN 2 GALLONS  
(508 mm) DIAMETER FOR  
WATER HEATERS HAVING A  
DIAMETER 18” (457 mm) OR  
LESS, 24” (610mm) DIAMETER  
FOR WATER HEATERS HAVING  
A DIAMETER 22” (559 mm) OR  
LESS AND AVAILABLE IN 28”  
(711 mm) DIAMETER FOR  
WATER HEATERS HAVING A  
DIAMETER 26” (660 mm) OR  
LESS.  
(7.6 LITERS) AND  
5 GALLONS (18.9 LITERS)  
CAPACITY HROUGH  
LOCAL SEARS STORE OR  
SERVICE CENTER.  
WATER HEATER INSTALLATION KIT WITH  
FLEXIBLE CONNECTORS FOR 3/4”  
(19.05 mm) OR 1/2” (12.7 mm) THREADED OR  
COPPER PLUMBING AND FLEXIBLE WATER  
HEATER GAS CONNECTOR WITH FITTINGS.  
Basic Tools  
Additional Tools Needed  
When Sweat Soldering  
You may or may not need all these tools, depending on your  
type of installation. These tools can be purchased at your local  
Sears Store.  
• Tubing Cutters or Hacksaw  
• Propane Tank  
• Soft Solder  
• Solder Flux  
• Emery Cloth  
• Pipe Wrenches (2) 14” (356 mm)  
• Screwdriver  
• Tin Snips  
• 6’ (1.82 m) Tape or Folding Ruler  
• Garden Hose  
• Wire Brushes  
• Drill  
• Pipe Dope or Teflon Tape  
DRILL  
PROPANE  
TORCH  
TUBING CUTTER  
SLOT-HEAD SCREWDRIVER  
PHILLIPS SCREWDRIVER  
TIN SNIPS  
ROLL OF  
EMERY CLOTH  
HACKSAW  
PIPE DOPE  
(SQUEEZE TUBE)  
USE FOR WATER AND GAS  
CONNECTIONS  
ROLL OF TEFLON  
TAPE (USE ONLY ON  
WATER CONNECTIONS)  
3/4” (19 mm) WIRE BRUSH  
ROLL OF LEAD-FREE  
SOFT SOLDER  
SOLDER  
FLUX  
6 FOOT TAPE  
GARDEN HOSE  
PIPE WRENCH  
1/2” (13 mm) WIRE BRUSH  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL INSTALLATION  
GET TO KNOW YOUR WATER HEATER - GAS MODELS  
A
B
C
D
E
F
G
H
I
Vent Pipe  
Draft Hood  
Anode  
Hot Water Outlet  
Outlet  
Flexible Water Connections  
Gas Supply  
Manual Gas Shut-off Valve  
Ground Joint Union  
J
K
L
M
N
O
P
Drip Leg (Sediment Trap)  
Inner Door  
Outer door  
S
T
U
V
W
X
Y
Flue Baffle  
Thermostat  
Drain Valve  
Pilot and Main Burner  
Flue  
Drain Pan  
Thermostat Shield (optional)  
Piezo Igniter  
Union  
Inlet Water Shut-off Valve  
Cold Water Inlet  
Inlet Dip Tube  
Temperature-Pressure Relief Valve  
Rating Plate  
Q
R
Z
AA Air Intake Screen  
(T) THERMOSTAT  
TO VENT TERMINATION  
ON ROOF  
Y
THERMOSTAT  
COVER  
(V) PILOT & MAIN BURNER  
(OPTIONAL)  
* ALL PIPING MATERIALS TO BE  
SUPPLIED BY CUSTOMERS.  
FIGURE1.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
4. Attach a hose to the water heater  
Removing the Old Water Heater  
drain valve and put the other end  
in a floor drain or outdoors. Open  
the water heater drain valve. Open  
a nearby hot water faucet which will  
relieve pressure in the water  
heater and speed draining. The  
water passing out of the drain valve  
may be extremely hot. To avoid  
being scalded, make sure all  
connections are tight and that the  
water flow is directed away from  
any person, see Figures 2 and 5.  
FIGURE5.  
5. Disconnect the vent pipe from the draft hood where it connects  
to the water heater. In most installations the vent pipe can  
be lifted off after any screw or other attached devices are  
removed. Dispose of the draft hood. The new water heater  
has a draft hood which must be used for proper operation.  
6. If you have copper piping to the water heater, the two copper  
water pipes can be cut with a hacksaw approximately four  
inches away from where they connect to the water heater,  
see Figure 6. This will avoid cutting off pipes too short.  
Additional cuts can be made later if necessary. Disconnect  
the temperature-pressure relief valve drain line. When the  
water heater is drained, disconnect the hose from the drain  
valve. Close the drain valve. The water heater is now  
completely disconnected and ready to be removed.  
FIGURE2.  
1. Turn “OFF” the gas supply to the  
water heater.  
If the main gas line Shut-off valve  
serving all gas appliances is  
used, also shut “OFF” the gas at  
each appliance. Leave all gas  
appliances shut “OFF” until the  
water heater installation is  
completed, see Figures 2 and 3.  
FIGURE6.  
FIGURE3.  
FIGURE4.  
If you have galvanized pipes to the water heater, loosen the  
two galvanized pipes with a pipe wrench at the union in each  
line. Also disconnect the piping remaining to the water heater,  
see Figure 7. These pieces should be saved since they may  
be needed when reconnecting the new water heater.  
Disconnect the temperature-pressure relief valve drain line.  
When the water heater is drained, disconnect the hose from  
the drain valve. Close the drain valve. The water heater is  
now completely disconnected and ready to be removed.  
Mineral buildup or sediment may have accumulated in the  
old water heater. This causes the water heater to be much  
heavier than normal and this residue, if spilled out, could  
cause staining.  
2. Turn “OFF” the water supply to the  
water heater at the water shut off  
valve or water meter. Some  
installations require that the water  
be turned off to the entire house,  
see Figures 2 and 4.  
3. Check again to make sure the gas supply is “OFF” to the  
water heater. Then disconnect the gas supply connection  
from the gas control valve.  
FIGURE7.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Devices that will turn off the gas supply to a gas water heater  
while at the same time shutting off its water supply.  
Facts to Consider About  
the Location  
Carefully choose an indoor location for the new water heater,  
because the placement is a very important consideration for  
the safety of the occupants in the building and for the most  
economical use of the appliance. This water heater is not for  
use in manufactured (mobile) homes or outdoor installation.  
Whether replacing an old water heater or putting the water heater  
in a new location, the following critical points must be observed:  
Select a location indoors as close as practical to the gas  
vent or chimney to which the water heater vent is going to be  
connected, and as centralized with the water piping system  
as possible.  
Selected location must provide adequate clearances for  
servicing and proper operation of the water heater.  
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS  
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED  
(GARAGES, STORAGE AND UTILITY AREAS, ETC.):  
Flammable liquids (such as gasoline, solvents, propane [LP or  
butane, etc.] and other substances such as adhesives, etc.)  
emit flammable vapors which can be ignited by a gas water  
heater’s pilot light or main burner. The resulting flashback and  
fire can cause death or serious burns to anyone in the area.  
Even though this water heater is a flammable vapors ignition  
resistant water heater and is designed to reduce the chances  
of flammable vapors being ignited, gasoline and other  
flammable substances should never be stored or used in the  
same vicinity or area containing a gas water heater or other  
open flame or spark producing appliance.  
Installation of the water heater must be accomplished in such a  
manner that if the tank or any connections should leak, the flow  
will not cause damage to the structure. For this reason, it is not  
advisable to install the water heater in an attic or upper floor.  
When such locations cannot be avoided, a suitable drain pan  
should be installed under the water heater. Drain pans are  
available at your local Sears or hardware store. Such a drain  
pan must have a minimum length and width of at least 2 inches  
(51 mm) greater that the water heater dimensions and must be  
piped to an adequate drain. The pan must not restrict  
combustion air flow.  
Also, the water heater must be located and/or protected so it is  
not subject to physical damage by a moving vehicle.  
Water heater life depends upon water quality, water pressure  
and the environment in which the water heater is installed.  
Water heaters are sometimes installed in locations where  
leakage may result in property damage, even with the use of a  
drain pan piped to a drain. However, unanticipated damage  
can be reduced or prevented by a leak detector or water shut-  
off device used in conjunction with a piped drain pan. These  
devices are available from some plumbing supply wholesalers  
and retailers, and detect and react to leakage in various ways:  
• Sensors mounted in the drain pan that trigger an alarm or turn  
off the incoming water to the water heater when leakage is  
detected.  
This water heater must not be installed directly on carpeting.  
Carpeting must be protected by metal or wood panel beneath  
the appliance extending beyond the full width and depth of the  
appliance by at least 3 inches (76.2 mm) in any direction, or if  
the appliance is installed in an alcove or closet, the entire floor  
must be covered by the panel. Failure to heed this warning may  
result in a fire hazard.  
• Sensors mounted in the drain pan that turn off the water supply  
to the entire home when water is detected in the drain pan.  
• Water supply shut-off devices that activate based on the water  
pressure differential between the cold water and hot water  
pipes connected to the water heater.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Minimum clearances between the water heater and combustible  
construction are inch at the sides and rear,  
0
4 inches (102 mm) at the front, and 6 inches (153 mm) from the  
vent pipe, see Figure 8. Clearance from the top of the jacket is 12  
inches (305 mm) on most models. Note that a lesser dimension  
may be allowed on some models, refer to the label attached  
adjacent to the gas control valve on the water heater.  
FIGURE9.  
If this water heater will be used in beauty shops, barber shops,  
cleaning establishments, or self-service laundries with dry  
cleaning equipment, it is imperative that the water heater or  
water heaters be installed so that combustion and ventilation  
air be taken directly from outdoors (direct vent).  
Propellants of aerosol sprays and volatile compounds,  
(cleaners, chlorine based chemicals, refrigerants, etc.) in  
addition to being highly flammable in many cases, will also  
change to corrosive hydrochloric acid when exposed to the  
combustion products of the water heater. The results can be  
hazardous, and also cause product failure.  
Insulation Blankets  
Insulation blankets available to the general public for external  
use on gas water heaters are not necessary with Kenmore  
products. The purpose of an insulation blanket is to reduce the  
standby heat loss encountered with storage tank heaters. Your  
Kenmore water heater meets or exceeds the NationalAppliance  
Energy Conservation Act standards with respect to insulation  
and standby loss requirements, making an insulation blanket  
unnecessary.  
FIGURE8.  
A gas water heater cannot operate properly without the correct  
amount of air for combustion, see Figure 9. Do not install in a  
confined area such as a closet, unless you provide air as shown  
in the Locating The New Water Heater section. Never obstruct  
the flow of ventilation air. If you have any doubts or questions at  
all, call your gas supplier. Failure to provide the proper amount  
of combustion air can result in a fire or explosion and cause  
death, serious bodily injury, or property damage.  
WARNING  
Should you choose to apply an insulation blanket to this heater,  
you should follow these instructions (See Figure 1 for  
identification of components mentioned below). Failure to follow  
these instructions can restrict the air flow required for proper  
combustion, potentially resulting in fire, asphyxiation, serious  
personal injury or death.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
commence within 12 inches (30 cm) of the top and one  
commencing within 12 inches (30 cm) of the bottom of the  
enclosures.  
Do not apply insulation to the top of the water heater, as this  
will interfere with safe operation of the draft hood.  
Do not cover the outer door, thermostat or temperature &  
pressure relief valve.  
Do not allow insulation to come within 2” (50.8 mm) of the  
floor to prevent blockage of combustion air flow to the burner.  
Do not cover the instruction manual. Keep it on the side of  
the water heater or nearby for future reference.  
Do obtain new warning and instruction labels from Sears  
for placement on the blanket directly over the existing labels.  
Do inspect the insulation blanket frequently to make certain  
it does not sag, thereby obstructing combustion air flow.  
Combustion Air and Ventilation for  
FIGURE10.  
Appliances Located in Unconfined Spaces  
B. ALLAIR FROM OUTDOORS: (See Figures 9, 11,12 and 13)  
UNCONFINED SPACE is space whose volume is not less than  
50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the  
aggregate input rating of all appliances installed in that space.  
Rooms communicating directly with the space in which the  
appliances are installed, through openings not furnished with  
doors, are considered a part of the unconfined space.  
The confined space shall be provided with two permanent  
openings, one commencing within 12 inches (30 cm) of the  
top and one commencing within 12 inches (30 cm) from the  
bottom of the enclosure. The openings shall communicate  
directly, or by ducts, with the outdoors or spaces (crawl or attic)  
that freely communicate with the outdoors.  
In unconfined spaces in buildings, infiltration may be adequate  
to provide air for combustion, ventilation and dilution of flue  
gases. However, in buildings of tight construction (for example,  
weather stripping, heavily insulated, caulked, vapor barrier, etc.),  
additional air may need to be provided using the methods  
described in Combustion Air and Ventilation for Appliances  
Located in Confined Spaces.  
Combustion Air and Ventilation for  
Appliances Located in Confined Spaces  
CONFINED SPACE is a space whose volume is less than  
50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the  
aggregate input rating of all appliances installed in that space.  
A. ALL AIR FROM INSIDE BUILDINGS:  
(See Figure 9 on page 9 and Figure 10 below)  
FIGURE11.  
The confined space shall be provided with two permanent  
openings communicating directly with an additional room(s)  
of sufficient volume so that the combined volume of all spaces  
meets the criteria for an unconfined space. The total input of  
all gas utilization equipment installed in the combined space  
shall be considered in making this determination. Each  
opening shall have a minimum free area of one square inch  
per 1,000 Btu per hour (22 cm2/kW) of the total input rating of all  
gas utilization equipment in the confined space, but not less  
than 100 square inches (645 cm2). One opening shall  
When directly communicating with the outdoors, each opening  
shall have a minimum free area of 1 square inch per 4,000 Btu  
per hour (5.5 cm2/kW) of total input rating of all equipment in the  
enclosure, see Figure 12.  
When communicating with the outdoors through vertical  
ducts, each opening shall have a minimum free area of  
1 square inch per 4,000 BTU per hour (5.5 cm2/kW) of total  
input rating of all equipment in the enclosure, see  
Figure 12.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Water Piping  
FIGURE12.  
HOTTER WATER CAN SCALD:  
When communicating with the outdoors through horizontal  
ducts, each opening shall have a minimum free area of 1  
square inch per 2,000 BTU per hour (11 cm2/kW) of total  
input rating of all equipment in the enclosure, see  
Figure 13.  
Water heaters are intended to produce hot water. Water heated  
to a temperature which will satisfy space heating, clothes  
washing, dish washing, cleaning and other sanitizing needs  
can scald and permanently injure you upon contact. Some  
people are more likely to be permanently injured by hot water  
than others. These include the elderly, children, the infirm, or  
physically/mentally handicapped. If anyone using hot water in  
your home fits into one of these groups or if there is a local  
code or state law requiring a certain temperature water at the  
hot water tap, then you must take special precautions. In  
addition to using the lowest possible temperature setting that  
satisfies your hot water needs, a means such as a *mixing  
valve, shall be used at the hot water taps used by these people  
or at the water heater. Mixing valves are available at plumbing  
supply or hardware stores, see Figure 14 below. Valves for  
reducing point of use temperature by mixing cold and hot water  
are also available. Follow manufacturer’s instructions for  
installation of the valves. Before changing the factory setting  
on the thermostat, read the Temperature Regulation section in  
this manual.  
When ducts are used, they shall be of the same cross-  
sectional area as the free area of the openings to which  
they connect. The minimum short side dimension of  
rectangular air ducts shall not be less than 3 inches  
(76.2 mm), see Figure 13.  
FIGURE13.  
Louvers and Grilles: In calculating free area, consideration  
shall be given to the blocking effect of louvers, grilles or  
screens protecting openings. Screens used shall not be  
smaller than 1/4 inch (6.4 mm) mesh. If the free area through  
a design of louver or grille is known, it should be used in  
calculating the size opening required to provide the free  
area specified. If the design and free area is not known, it  
may be assumed that wood louvers will be 20-25 percent  
free area and metal louvers and grilles will have 60-75  
percent free area. Louvers and grilles shall be fixed in the  
open position or interlocked with the equipment so that they  
are opened automatically during equipment operation.  
FIGURE14.  
Special Conditions Created by Mechanical Exhausting or  
Fireplaces: operation of exhaust fans, ventilation systems,  
clothes dryers or fireplaces may create conditions requiring  
special attention to avoid unsatisfactory operation of installed  
gas utilization equipment.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This water heater shall not be connected to any heating systems  
or component(s) used with a non-potable water heating  
appliance.  
Look at the top of the water heater. The cold water inlet is  
marked “COLD”. Put two or three turns of teflon tape around  
the threaded end of the threaded-to-sweat coupling and  
around both ends of the 3/4” NPT threaded nipple. Using  
flexible connectors, connect the cold water pipe to the cold  
water inlet of the water heater.  
All piping components connected to this unit for space heating  
applications shall be suitable for use with potable water.  
NOTE: This water heater is super insulated to minimize  
heat loss from the tank. Further reduction in heat loss  
can be accomplished by insulating the hot water lines  
from the water heater.  
Toxic chemicals, such as those used for boiler treatment shall  
not be introduced into this system.  
Water supply systems may, because of such events as high  
line pressure, frequent cut-offs or the effects of water hammer  
among others, have installed devices such as pressure  
reducing valves, check valves, back flow preventers, etc. to  
control these types of problems. When these devices are not  
equipped with an internal by-pass, and no other measures are  
taken, the devices cause the water system to be closed. As  
water is heated, it expands (thermal expansion) and closed  
systems do not allow for the expansion of heated water.  
INSTALLATION COMPLETED USING  
INSTALLATION KIT  
The water within the water heater tank expands as it is heated  
and increases the pressure of the water system. If the relieving  
point of the water heater’s temperature-pressure relief valve is  
reached, the valve will relieve the excess pressure. The  
temperature-pressure relief valve is not intended for the  
constant relief of thermal expansion. This is an unacceptable  
condition and must be corrected. It is recommended that any  
devices installed which could create a closed system have a  
by-pass and/or the system have an expansion tank to relieve  
the pressure built by thermal expansion in the water system.  
Refer to the Thermal Expansion section under Troubleshooting  
Guide or contact local plumbing authority or local Sears Service  
Center on how to control this situation.  
NOTE: To protect against untimely corrosion of hot and cold  
water fittings, it is strongly recommended that di-electric  
unions or couplings be installed on this water heater when  
connected to copper pipe.  
FIGURE15.  
T & P Valve and Pipe Insulation  
Remove insulation for T & P valve and pipe connections from  
carton.  
Figure 15 shows the typical attachment of the water piping to  
the water heater. The water heater is equipped with 3/4” NPT  
water connections.  
NOTE: If using copper tubing, solder tubing to an adapter  
before attaching the adapter to the cold water inlet  
connection. Do not solder the cold water supply line directly  
to the cold water inlet. It will harm the dip tube and damage  
the tank.  
Look at the top cover of the water heater. The water outlet is  
marked “HOT”. Put two or three turns of teflon tape around  
the threaded end of the threaded-to-sweat coupling and  
around both ends of the 3/4” NPT threaded nipple. Using  
flexible connectors, connect the hot water pipe to the hot  
water outlet on the water heater.  
FIGURE15A.  
Fit pipe insulation over the incoming cold water line and the hot  
water line. Make sure that the insulation is against the top  
cover of the heater.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fit T & P valve insulation over valve. Make sure that the insulation  
does not interfere with the lever of the T & P valve.  
Secure all insulation using tape.  
Temperature-Pressure Relief Valve  
FIGURE16.  
This heater is provided with a properly certified combination  
temperature - pressure relief valve by the manufacturer.  
The valve is certified by a nationally recognized testing  
laboratory that maintains periodic inspection of production of  
listed equipment as meeting the requirements for Relief Valves  
and Automatic Gas Shut-off Devices for Hot Water Supply  
Systems, ANSI Z21.22 and the code requirements of ASME.  
If replaced, the valve must meet the requirements of local  
codes, but not less than a combination temperature and  
pressure relief valve certified as indicated in the above  
paragraph.  
The Discharge Pipe:  
• Shall not be smaller in size than the outlet pipe size of the  
valve, or have any reducing couplings or other restrictions.  
The valve must be marked with a maximum set pressure not to  
exceed the marked hydrostatic working pressure of the water  
heater (150 psi = 1,035kPa) and a discharge capacity not less  
than the water heater input rate as shown on the model rating  
plate.  
• Shall not be plugged or blocked.  
• Shall be of material listed for hot water distribution.  
• Shall be installed so as to allow complete drainage of both  
the temperature-pressure relief valve, and the discharge  
pipe.  
For safe operation of the water heater, the relief valve must not  
be removed from its designated opening nor plugged.  
• Shall terminate at an adequate drain.  
The temperature-pressure relief valve must be installed directly  
into the fitting of the water heater designed for the relief valve.  
Position the valve downward and provide tubing so that any  
discharge will exit only within 6 inches (153 mm) above, or at  
any distance below the structural floor, see Figure 16. Be certain  
that no contact is made with any live electrical part. The  
discharge opening must not be blocked or reduced in size  
under any circumstances. Excessive length, over 30 feet  
(9.14 m), or use of more than four elbows can cause restriction  
and reduce the discharge capacity of the valve.  
• Shall not have any valve between the relief valve and tank.  
No valve or other obstruction is to be placed between the relief  
valve and the tank. Do not connect tubing directly to discharge  
drain unless a 6 inch air gap is provided. To prevent bodily  
injury, hazard to life, or property damage, the relief valve must  
be allowed to discharge water in quantities should  
circumstances demand. If the discharge pipe is not connected  
to a drain or other suitable means, the water flow may cause  
property damage.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The temperature-pressure relief valve must be manually  
operated at least once a year. Caution should be taken to  
ensure that (1) no one is in front of or around the outlet of the  
temperature-pressure relief valve discharge line, and (2) the  
water manually discharged will not cause any bodily injury or  
property damage because the water may be extremely hot.  
and mechanically actuated vent dampers). Before installation  
of any vent damper, consult your local Sears Service Center or  
the local gas supplier for further information.  
If after manually operating the valve, it fails to completely reset  
and continues to release water, immediately close the cold  
water inlet to the water heater, follow the draining instructions,  
and replace the temperature-pressure relief valve with a new  
one.  
Filling the Water Heater  
Never use this water heater unless it is completely full of water.  
To prevent damage to the tank, the tank must be filled with  
water. Water must flow from the hot water faucet before turning  
“ON” gas to the water heater.  
To insure proper venting of this gas-fired water heater, the  
correct vent pipe diameter must be utilized. Any additions or  
deletions of other gas appliances on a common vent with this  
water heater may adversely affect the operation of the water  
heater. Consult your gas supplier if any such changes are  
planned. For replacement heater installations where using pre-  
existing venting, venting must be inspected for obstructions  
and if deterioration is present, venting must be replaced.  
To fill the water heater with water:  
Close the water heater drain valve by turning the handle to  
the right (clockwise). The drain valve is on the lower front of  
the water heater.  
For proper venting in certain installations, a larger diameter  
vent pipe may be necessary. Consult your local Sears Service  
Center or gas supplier to aid you in determining the proper  
venting for your water heater from the vent tables in the current  
edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.  
Open the cold water supply valve to the water heater.  
NOTE: The cold water supply valve must be left open when  
the water heater is in use.  
To insure complete filling of the tank, allow air to exit by  
opening the nearest hot water faucet. Allow water to run  
until a constant flow is obtained. This will let air out of the  
water heater and the piping.  
Periodically check the venting system for signs of obstruction  
or deterioration and replace if needed.  
The combustion and ventilation air flow must not be obstructed.  
Check all water piping and connections for leaks. Repair  
as needed.  
The water heater with draft hood installed must be connected  
to a chimney or listed vent pipe system, which terminates to  
the outdoors. Never operate the water heater unless it is vented  
to the outdoors and has adequate air supply to avoid risks of  
improper operation, explosion or asphyxiation.  
Venting  
VENT DAMPERS - Any vent damper, whether it is operated  
thermally or otherwise must be removed if its use inhibits proper  
drafting of the water heater.  
For proper draft hood attachment, the draft hood legs may  
be angled slightly inward.  
Place the draft hood legs in the receiving holes on the top of  
the water heater. The legs will snap in the holes to give a  
tight fit. Secure two legs to top with sheet metal screws.  
Thermally Operated Vent Dampers: Gas-fired water heaters  
having thermal efficiency in excess of 80% may produce a  
relatively low flue gas temperature. Such temperatures may  
not be high enough to properly open thermally operated vent  
dampers. This would cause spillage of the flue gases and  
may cause carbon monoxide poisoning.  
Place the vent pipe over the draft hood. With the vent pipe in  
position, drill a small hole through both the vent pipe and  
draft hood. Secure them together with a sheet metal screw,  
see Figure 17.  
Vent dampers must bear evidence of certification as complying  
with the current edition of the American National Standard  
ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically  
Obstructed or deteriorated vent systems may present serious  
health risk or asphyxiation.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Be sure vent pipe is properly connected to prevent escape of  
dangerous flue gases which could cause deadly asphyxiation.  
Chemical vapor corrosion of the flue and vent system may  
occur if air for combustion contains certain chemical vapors.  
Spray can propellants, cleaning solvents, refrigerator and air  
conditioner refrigerants, swimming pool chemicals, calcium  
and sodium chloride, waxes, bleach and process chemicals  
are typical compounds which are potentially corrosive.  
Gas Piping  
FIGURE17.  
The vent pipe from the water heater must be no less than the  
diameter of the draft hood outlet on the water heater and must  
slope upward at least 1/4 inch per linear foot (21 mm per meter),  
see Figure 18.  
FIGURE18.  
Make sure the gas supplied is the same type listed on the  
model rating plate. The inlet gas pressure must not exceed  
14 inch water column (3.5kPa) for natural and propane gas  
(L.P.). The minimum inlet gas pressure listed on the rating  
plate is for the purpose of input adjustment. If the gas control  
valve is subjected to pressures exceeding 1/2 pound per square  
inch (3.5kPa), the damage to the gas control valve could result  
in a fire or explosion from leaking gas.  
All vent gases must be completely vented to the outdoors of the  
structure (dwelling). Install only the draft hood provided with  
the new water heater and no other draft hood.  
Vent pipes must be secured at each joint with sheet metal  
screws.  
There must be a minimum of 6 inches (153 mm) clearance  
between single wall vent pipe and any combustible material.  
Fill and seal any clearance between single wall vent pipe and  
combustible material with mortar mix, cement, or other  
noncombustible substance. For other than single wall, follow  
vent pipe manufacturer’s clearance specifications. To insure  
a tight fit of the vent pipe in a brick chimney, seal around the  
If the main gas line shut-off serving all gas appliances is used,  
also turn “OFF” the gas at each appliance. Leave all gas  
appliances shut “OFF” until the water heater installation is  
complete.  
vent pipe with mortar mix cement.  
A gas line of sufficient size must be run to the water heater.  
Consult the current edition of National Fuel Gas Code ANSI  
Z223.1/NFPA 54 and your gas supplier concerning pipe size.  
There must be:  
A readily accessible manual shut off valve in the gas supply  
line serving the water heater, and  
A drip leg (sediment trap) ahead of the gas control valve to  
help prevent dirt and foreign materials from entering the  
gas control valve.  
A flexible gas connector or a ground joint union between the  
shut off valve and control valve to permit servicing of the unit.  
Be sure to check all the gas piping for leaks before lighting the  
water heater. Use a soapy water solution, not a match or open  
flame. Rinse off soapy solution and wipe dry.  
The minimum inlet gas pressure shown on the rating plate is  
that which will permit firing at the rated input.  
Failure to have required clearances between vent piping and  
combustible material will result in a fire hazard.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sediment Traps  
Contaminants in the gas lines may cause improper operation  
of the gas control valve that may result in fire or explosion.  
Before attaching the gas line be sure that all gas pipe is clean  
on the inside. To trap any dirt or foreign material in the gas  
supply line, a drip leg (sometimes called a sediment trap)  
must be incorporated in the piping. The drip leg must be readily  
accessible. Install in accordance with the Gas Piping section.  
Refer to the current edition of the National Fuel Gas Code,  
ANSI Z223.1/NFPA54.  
Water heaters covered in this manual have been tested and  
approved for installation at elevations up to 7,700 feet (2,347m)  
above sea level. For installation above 7,700 feet (2,347m),  
the water heater’s Btu input should be reduced at the rate of 4  
percent for each 1,000 feet (305 m) above sea level which  
requires replacement of the burner orifice in accordance with  
the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact  
your local gas supplier for further information.  
Failure to replace the standard orifice with the proper high  
altitude orifice when installed at elevations above 7,700 feet  
(2,347m) could result in improper and inefficient operation of  
the appliance, producing carbon monoxide gas in excess of  
the safe limits. This could result in serious injury or death.  
Contact your local gas supplier for any specific changes that  
may be required in your area.  
A sediment trap shall be installed as close to the inlet of the  
water heater as practical at the time of water heater installation.  
The sediment trap shall be either a tee fitting with a capped  
nipple in the bottom outlet or other device recognized as an  
effective sediment trap. If a tee fitting is used, it shall be installed  
in conformance with one of the methods of installation, shown  
in Figures 19 and 20.  
Use pipe joint compound or teflon tape marked as being  
resistant to the action of petroleum (Propane [L.P.]) gases.  
FIGURE19. GASPIPINGWITHFLEXIBLECONNECTOR.  
The appliance and its gas connection must be leak tested  
before placing the appliance in operation.  
The appliance and its individual shut-off valve shall be  
disconnected from the gas supply piping system during any  
pressure testing of that system at test pressures in excess of  
1/2 pound per square inch (3.5 kPa). It shall be isolated from  
the gas supply piping system by closing its individual manual  
shut-off valve during any pressure testing of the gas supply  
piping system at test pressures equal to or less than 1/2 pound  
per square inch (3.5 kPa).  
Connecting the gas piping to the gas control valve of the water  
heater can be accomplished by either of the two methods  
shown in Figures 19 and 20.  
FIGURE 20. GAS PIPING WITH ALL  
BLACK IRON PIPE TO GAS CONTROL.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: If you do not follow these instructions exactly, a fire or  
explosion may result causing property damage, personal injury or loss of life.  
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATERANDAIR PURGED FROM ALL LINES.  
A. This appliance has a pilot which is lit by a piezo electric  
gas ignition system. Do not open the inner door of the  
appliance and try to light the pilot by hand.  
If you cannot reach your gas supplier, call the fire  
department.  
C. Use only your hand to push in or turn the gas control  
knob. Never use tools. If the knob will not push in or turn  
by hand, don’t try to repair it, call a qualified service  
technician . Force or attempted repair may result in a fire  
or explosion.  
B. BEFORE LIGHTING smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor.  
WHAT TO DO IFYOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electric switch; do not use any phone  
in your building.  
Immediately call your gas supplier from a neighbor’s  
phone. Follow the gas supplier’s instructions.  
D. Do not use this appliance if any part has been under  
water. Immediately contact a qualified installer or service  
agency to replace a flooded water heater. Do not attempt  
to repair the unit! It must be replaced!  
LIGHTING INSTRUCTIONS  
TOP KNOB  
FIGURE “D”  
1.  
STOP! Read the safety information  
above on this label.  
2. Set the thermostat to lowest setting (PILOT LIGHTING).  
Turn thermostat dial fully clockwise until it stops.  
9. Once the pilot has been found, push the gas knob all the  
way down. Immediately press the pilot igniter button rapidly  
(4) to (5) times. If the pilot will not light, repeat step (3)  
through (9).  
10. Continue to hold the gas control knob down for about one  
(1) minute after the pilot is lit. Release the gas control knob  
and it will pop back up. Pilot should remain lit. If it goes out,  
repeat step (3) through (9). It may take several minutes for  
air to clear the lines before the pilot will light.  
3. Push the gas control knob down slightly and turn clockwise  
to “OFF”, SEE FIGURE “A”.  
NOTE: Knob CANNOT be turned from “PILOT” to “OFF”  
unless it is pushed down slightly. Do not force.  
4. Remove the outer burner door located below the gas  
control.  
If knob does not pop up when released, stop and  
immediately call your service technician or gas supplier.  
If the pilot will not stay lit after several tries, turn the gas  
5. Wait five (5) minutes to clear out any gas. If you then  
smell gas,  
STOP! Follow “B” in the safety information  
control knob clockwise  
to “OFF” and call your service  
above on this label. If you don’t smell gas, go to next step.  
6. This unit is equipped with a push button pilot igniter, which  
is used to light the pilot. Locate the igniter on the gas  
control.  
technician or gas supplier. SEE FIGURE “A”.  
11. Once the pilot flame is established replace the outer burner  
door.  
12. At arms length away, turn gas control knob  
7. Turn gas control knob counterclockwise  
to “PILOT”,  
counterclockwise  
to “ON”. SEE FIGURE “C”.  
SEEFIGURE “B”.  
13. Set thermostat to desired setting.  
8. The pilot is located on the right side of the burner. It can be  
located by looking through the glass view port while  
pressing the piezo igniter button several times. Look for a  
spark at the pilot location, FIGURE “D”.  
DANGER: Hotter water increases the risk of  
scald injury. Consult the instruction manual  
before changing temperature.  
TO TURN OFF GAS TO APPLIANCE  
2. Push gas control knob down slightly and turn clockwise  
to “OFF”. Do not force. SEE FIGURE “A”.  
1. Set thermostat to the lowest setting (PILOT LIGHTING).  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temperature Regulation  
THE WATER HEATER SHOULD BE LOCATED IN AN AREA  
WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS.  
IFASUITABLEAREAIS NOTAVAILABLE,ACOVER SHOULD BE  
INSTALLED OVER THE THERMOSTAT TO PREVENT  
TAMPERING. Suitable covers are available through the Sears  
Service Center.  
Due to the nature of the typical gas water heater, the water  
temperature in certain situations may vary up to 30F° (16.7 C°)  
higher or lower at the point of use such as, bathtubs, showers,  
sink, etc.  
Any water heater’s intended purpose is to heat water. Hot  
water is needed for cleansing, cleaning, and sanitizing (bodies,  
dishes, clothing). Untempered hot water can present a scald  
hazard. Depending on the time element, and the people  
involved (adults, children, elderly, infirm, etc.) scalding may occur  
at different temperatures.  
Never allow small children to use a hot water tap, or to draw  
their own bath water. Never leave a child or handicapped person  
unattended in a bathtub or shower.  
NOTE: A water temperature range of 120°F-140°F (49°C-60°C)  
is recommended by most dishwasher manufacturers.  
The thermostat of this water heater has been factory set at its  
lowest position (PILOT LIGHTING). It is adjustable and must  
be reset to the desired temperature setting to reduce the risk of  
scald injury. The mark ( ) indicative of approximately 120°F  
(49°C) is preferred starting point. Some states have a  
requirement for a lower setting.  
Turn the water temperature dial clockwise (  
the temperature, or counterclockwise (  
temperature.  
) to decrease  
) to increase the  
Should overheating occur or the gas supply fail to shut off, turn  
off the manual gas control valve to the appliance.  
HOTTER WATER CAN SCALD: Water heaters are intended to  
produce hot water. Water heated to a temperature which will  
satisfy space heating, clothes washing, dish washing, and  
other sanitizing needs can scald and permanently injure you  
upon contact. Some people are more likely to be permanently  
injured by hot water than others. These include the elderly,  
children, the infirm, or physically/mentally handicapped. If  
anyone using hot water in your home fits into one of these  
groups or if there is a local code or state law requiring a certain  
temperature water at the hot water tap, then you must take  
special precautions. In addition to using the lowest possible  
temperature setting that satisfies your hot water needs, a  
means such as a mixing valve, shall be used at the hot water  
taps used by these people or at the water heater. Mixing valves  
are available at plumbing supply or hardware stores. Follow  
manufacturer’s instructions for installation of the valves. Before  
changing the factory setting on the thermostat, read the  
Temperature Regulation section in this manual, see Figures  
21 and 22.  
FIGURE21.  
Temperature  
Settings  
Time to Produce 2nd & 3rd  
Degree Burns on Adult Skin  
VERYHOT=approx.160°F(71°C)  
C = approx. 150°F (66°C)  
B = approx. 140°F (60°C)  
A = approx. 130°F (54°C)  
= approx. 120°F (49°C)  
About 1/2 second  
About 1-1/2 seconds  
Less than 5 seconds  
About 30 seconds  
More than 5 minutes  
LOW = approx. 80°F (27°C)  
- - - - - - - - - - - - - - - -  
FIGURE22.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE AND ADJUSTMENT  
Tank (Sediment) Cleaning  
Burner Inspection  
Flood damage to a water heater may not be readily visible or  
immediately detectable. However, over a period of time a  
flooded water heater will create dangerous conditions which  
can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE. Contact a Sears Service Center to replace a flooded  
water heater. Do not attempt to repair the unit! It must be  
replaced!  
Sediment build-up on the tank bottom may create varying  
amount of noise, and if left in the tank will cause permanent  
tank failure. In some water areas, you may not be able to drain  
all sediment deposits by simply draining the tank. In these  
cases Mag-Erad (part no. 23600) can be used to help remove  
the sediment deposits. This may be ordered from the Sears  
Service Center. For ordering, refer to the Parts Order List  
section.  
At least once a year a visual inspection should be made of the  
main burner and pilot burner, see Figure 23.  
Vent System Inspection  
You should check for sooting. Soot is not normal and will impair  
proper combustion.  
Soot build-up indicates a problem that requires correction  
before further use. Turn “OFF” gas to water heater and  
leave off until repairs are made, because failure to correct the  
cause of the sooting can result in a fire causing death, serious  
injury, or property damage.  
Flue gases may escape if vent pipe  
is not connected.  
Be alert for obstructed, sooted or  
deteriorated vent system to avoid  
serious injury or death.  
Do not store corrosive chemicals  
in vicinity of water heater.  
Chemical corrosion of flue and vent  
system can cause serious injury or  
death  
FIGURE23.  
Burner Cleaning  
At least once a year a visual inspection should be made of the  
venting system. You should look for:  
Obstructions which could cause improper venting. The  
combustion and ventilation air flow must not be obstructed.  
Damage or deterioration which could cause improper  
venting or leakage of combustion products.  
Rusted flakes around top of water heater.  
Be sure the vent piping is properly connected to prevent escape  
of dangerous flue gasses which could cause deadly  
asphyxiation.  
Obstructions and deteriorated vent systems may present  
serious health risk or asphyxiation.  
In the event your burner needs cleaning, following these  
instructions:  
Chemical vapor corrosion of the flue and vent system may  
occur if air for combustion contains certain chemical vapors.  
Spray can propellants, cleaning solvents, refrigerator and air  
conditioner refrigerants, swimming pool chemicals, calcium  
and sodium chloride, waxes, bleach and process chemicals  
are typical compounds which are potentially corrosive.  
If inspection of the burner shows that cleaning is required, turn  
the gas control knob clockwise (  
depressing slightly.  
) to the “OFF” position,  
NOTE: The knob cannot be turned from “PILOT” to “OFF”  
unless knob is depressed slightly. DO NOT FORCE.  
If when inspecting the vent system you find sooting or  
deterioration, something is wrong. Call the local gas supplier  
to correct the problem and clean or replace the flue and venting  
before resuming operation of the water heater.  
The burner needs to be removed for cleaning. Call the Sears  
Service Center to remove and clean the burner and correct the  
problem that required the burner to be cleaned.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Housekeeping  
Temperature-Pressure Relief Valve Operation  
Vacuum around base of water heater for dust, dirt, and lint on a  
regular basis.  
The temperature-pressure relief valve must be manually  
operated at least once a year.  
When checking the temperature-pressure relief valve operation,  
make sure that (1) no one is in front of or around the outlet of  
the temperature-pressure relief valve discharge line, and (2)  
that the water discharge will not cause any property damage,  
as the water may be extremely hot, see Figure 24.  
AT LEAST ONCE EVERY SIX MONTHS A  
VISUAL INSPECTION SHOULD BE MADE OF  
THE AIR INTAKE SCREEN. CLEAN IF LINT  
ACCUMULATIONS ARE NOTICED.  
INSTALLED IN SUITABLEAREA: To insure sufficient ventilation  
and combustion air supply, proper clearances from the water  
heater must be maintained. See Facts to Consider About the  
Location section. Combustible materials such as clothing,  
cleaning materials, or flammable liquids, etc. must not be  
placed against or adjacent to the water heater because they  
could catch on fire.  
FIGURE 24.  
If after manually operating the valve, it fails to completely reset  
and continues to release water, immediately close the cold  
water inlet to the water heater, follow the draining instructions,  
and replace the temperature-pressure relief valve with a new  
one.  
Anode Rod Inspection  
If the temperature-pressure relief valve on the appliance weeps  
or discharges periodically, this may be due to thermal  
expansion. You may have a check valve installed in the water  
line or a water meter with a check valve. Consult the Sears  
Service Center for further information. Do not plug the  
temperature-pressure relief valve.  
Draining  
The anode rod is used to protect the tank from corrosion. Most  
hot water tanks are equipped with an anode rod. The  
submerged rod deteriorates to protect the tank. Instead of  
corroding the tank, water ions attack and eat away the anode  
rod. This does not affect the water’s taste or color. The rod  
must be maintained to keep the tank in operating condition.  
Anode deterioration depends on water conductivity, not  
necessarily water condition. A corroded or pitted anode rod  
indicates high water conductivity and should be checked and/  
or replaced more often than an anode rod that appears to be  
intact. Replacement of a depleted anode rod can extend the  
life of your water heater. Inspection should be conducted by  
calling the Sears Service Center for an authorized contractor. At  
a minimum, the anode(s) should be checked annually after  
the warranty period.  
The water heater should be drained if being shut down during  
freezing temperatures. Also periodic draining and cleaning of  
sediment from the tank may be necessary.  
1. Turn the gas control knob to the “OFF” position.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. CLOSE the cold water inlet valve to the water heater.  
5. Screw the handle and cap assembly back into the drain  
valve and retighten using a wrench. DO NOT OVER  
TIGHTEN.  
3. OPEN a nearby hot water faucet and leave open to allow for  
draining.  
6. Follow instructions in the Filling The Water Heater section.  
4. Connect a hose to the drain valve and terminate to an  
adequate drain.  
7. Check for leaks.  
8. Follow the lighting instructions in the Lighting section to  
5. OPEN the water heater drain valve to allow for tank draining.  
restart the water heater.  
NOTE: If the water heater is going to be shut down and  
drained for an extended period, the drain valve should be  
left open with hose connected allowing water to terminate  
to an adequate drain.  
6. CLOSE the drain valve.  
7. Follow instructions in the Filling The Water heater section.  
8. Follow the lighting instructions in the Lighting section to  
restart the water heater.  
FIGURE 25.  
Drain Valve Washer Replacement  
(See Figure 25)  
Service  
Before calling for repair service, read the Start Up Conditions  
and Operational Conditions found in the Troubleshooting Guide  
of this manual.  
1. Turn “OFF” gas supply to water heater.  
2. Follow “Draining” instructions.  
If a condition persists or you are uncertain about the operation  
of the water heater, let the Sears Service Center check it out.  
3. Turning counter clockwise (  
the screw handle.  
), remove the hex cap below  
Contact Sears Service Center at:  
4. Remove the washer and put the new one in place.  
1-800-4-MY-HOME® (1-800-469-4663).  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
NOTE: Expansion tanks are pre-charged with a 40 psi air  
Start Up Conditions  
charge. If the inlet water pressure is higher than 40 psi, the  
expansion tank’s air pressure must be adjusted to match  
that pressure, but must not be higher than 80 psi.  
Thermal Expansion  
Water supply system may, because of such events as high line  
pressure, frequent cut-offs, and the effects of water hammer  
have installed devices such as pressure reducing valves, check  
valves, back flow preventers, etc., to control these types of  
problems. When these devices are not equipped with an  
internal by-pass, and no other measures are taken, the devices  
cause the water system to be closed. As water is heated, it  
expands (thermal expansion) and closed systems do not allow  
for the expansion of heated water.  
The water within the water heater tank expands as it is heated  
and increases the pressure of the water system. If the relieving  
point of water heater’s temperature-pressure relief valve is  
reached, the valve will relief the excess pressure. The  
temperature-pressure relief valve is not intended for the  
constant relief of thermal expansion. This is an unacceptable  
condition and must be corrected.  
It is recommended that any devices installed which could create  
a closed system have a by-pass and/or the system have an  
expansion tank or device to relieve the pressure built by thermal  
expansion. Thermal expansion tanks are available from Sears  
stores and through the Sears Service Centers. Contact the  
local plumbing inspector, water supplier and/or the Sears  
Service Center for assistance in controlling these situations,  
see Figure 26.  
Thermal Expansion Tank Specifications  
FIGURE26.  
Tank  
Capacity  
Dimensions  
in Inches  
Pipe  
Fitting  
Model  
Strange Sounds  
Number In Gallons Diameter  
Length  
On Tank  
153.331020  
153.331050  
2
5
8 (203 mm) 12-3/4 (323 mm) 3/4” Male  
11 (279 mm) 14-3/4 (375 mm) 3/4” Male  
Possible noises due to expansion and contraction of some  
metal parts during periods of heat-up and cool-down do not  
represent harmful or dangerous conditions.  
Expansion Tank Sizing Chart  
Condensation causes sizzling and popping within the burner  
area during heating and cooling periods and should be  
considered normal. See Condensation section.  
Inlet*  
Water  
Pressure 30  
40psi  
50psi  
60psi  
70psi  
80psi  
Water Heater Capacity (Gallons)  
40  
2
50  
2
66  
5
80  
5
Expansion  
Tank  
Capacity  
Needed  
2
2
2
2
2
Draft Hood Operation  
2
2
5
5
2
5
5
5
Check draft hood operation by performing a worst case  
depressurization of the building. With all doors and windows  
closed, and with all air handling equipment and exhaust fans  
operating such as furnaces, clothes dryers, range hoods and  
bathroom fans, a match flame should still be drawn into the  
draft hood of the water heater with its burner firing. If the flame  
2
5
5
5
5
5
5
5
*Highest recorded inlet water pressure in a 24 hour period or  
regulated water pressure.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
is not drawn toward the draft hood, shut off water heater and  
make necessary air supply changes to correct.  
from hydrogen sulfide gas dissolved in the water. The smell is  
the result of four factors which must all be present for the odor  
to develop:  
Condensation  
a concentration of sulfate in the supply water.  
little or no dissolved oxygen in the water.  
Whenever the water heater is filled with cold water, some  
condensate will form while the burner is on. A water heater  
may appear to be leaking when in fact the water is condensation.  
This usually happens when:  
a sulfate reducing bacteria within the water heater. (This  
harmless bacteria is non-toxic to humans.)  
an excess of active hydrogen in the tank. This is caused by  
the corrosion protective action of the anode.  
A new water heater is filled with cold water for the first time.  
Burning gas produces water vapor In water heaters,  
particularly high efficiency models where flue temperatures  
are lower.  
Smelly water may be eliminated or reduced in some water  
heater models by replacing the anode(s) with one of less active  
material, and then chlorinating the water heater tank and all  
hot water lines. Contact Sears Service for further information  
concerning an Anode Replacement Kit #9001453 and this  
Chlorination Treatment. Anode replacement and chlorination  
of the tank are not covered by the water heater’s limited warranty.  
Large amounts of hot water are used in a short time and the  
refill water in the tank is very cold.  
Moisture from the products of combustion condense on the  
cooler tank surfaces and form drops of water which may fall  
onto the burner or other hot surfaces to produce a “sizzling” or  
“frying” noise.  
If the smelly water persists after the anode replacement and  
chlorination treatment, it may be necessary to chlorinate or  
aerate your water supply to eliminate the problem.  
Do not remove the anode leaving the tank unprotected. By  
doing so, all warranty on the water heater tank is voided.  
Excessive condensation can cause pilot outage due to water  
running down the flue tube onto the main burner and putting  
out the pilot.  
“AIR” In Hot Water Faucets  
Because of the suddenness and amount of water,  
condensation water may be diagnosed as a “tank leak”. After  
the water in the tank warms up (about 1-2 hours), the condition  
should disappear.  
Do not assume the water heater is leaking until there has  
been enough time for the water in the tank to warm up.  
An undersized water heater will cause more condensation.  
The water heater must be sized properly to meet the family’s  
demands for hot water including dishwashers, washing  
machines and shower heads.  
Excessive condensation may be noticed during the winter and  
early spring months when incoming water temperatures are at  
their lowest.  
HYDROGEN GAS: Hydrogen gas can be produced in a hot  
water system that has not been used for a long period of time  
(generally two weeks or more). Hydrogen gas is extremely  
flammable and explosive. To prevent the possibility of injury  
under these conditions, we recommend the hot water faucet,  
located farthest away, be opened for several minutes before  
any electrical appliances which are connected to the hot water  
system are used (such as a dishwasher or washing machine).  
If hydrogen gas is present, there will probably be an unusual  
sound similar to air escaping through the pipe as the hot water  
faucet is opened. There must be no smoking or open flame  
near the faucet at the time it is open.  
Good venting is essential for a gas fired water heater to operate  
properly as well as to carry away products of combustion and  
water vapor.  
Smoke Odor  
It is not uncommon to experience a small amount of smoke  
and odor during the initial start-up. This is due to burning off of  
oil from metal parts, and will disappear in a short while.  
High Temperature Shut-Off System  
Operational Conditions  
This water heater is equipped with an automatic gas shutoff  
system. This system works when high water temperatures  
are present. Turn “OFF” the entire gas supply to the water  
heater. The high temperature shutoff is built into the gas control  
valve. It is non-resettable. If the high temperature shutoff  
activates, the gas control valve must be replaced. Contact your  
gas supplier.  
Smelly Odor  
In each water heater there is installed at least one anode rod  
(see parts section) for corrosion protection of the tank. Certain  
water conditions will cause a reaction between this rod and  
the water. The most common complaint associated with the  
anode rod is one of a “rotten egg smell”. This odor is derived  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Read this manual first. Then before checking the water heater  
make sure the gas supply has been turned “OFF”, and never  
turn the gas “ON” before the tank is completely full of water.  
Operational Conditions (Continued)  
Leakage Checkpoints  
Never use this water heater unless it is completely filled with  
water. To prevent damage to the tank, the tank must be filled  
with water. Water must flow from the hot water faucet before  
turning “ON” gas to the water heater, see Figure 27.  
A. Water at the draft hood is water vapor which has condensed  
out of the combustion products. This is caused by a problem  
in the vent. Contact the gas utility.  
B. *Condensation may be seen on pipes in humid weather or  
pipe connections may be leaking.  
C. *The anode rod fitting may be leaking.  
D. Small amounts of water from temperature-pressure relief  
valve may be due to thermal expansion or high water  
pressure in your area.  
E. *The temperature-pressure relief valve may be leaking at  
the tank fitting.  
F. Water from a drain valve may be due to the valve being  
slightly opened.  
G. *The drain valve may be leaking at the tank fitting.  
H. Combustion products contain water vapor which can  
condense on the cooler surfaces of the tank. Droplets form  
and drip onto the burner or run on the floor. This is common  
at the time of start-up after installation and when incoming  
water is cold.  
I. Water in the water heater bottom or on the floor may be from  
condensation, loose connections, or the relief valve.  
DO NOT replace the water heater until a full inspection of all  
possible water sources is made and necessary corrective  
steps taken.  
FIGURE27.  
Leakage from other appliances, water lines, or ground seepage  
should also be checked.  
*
To check where threaded portion enters tank, insert cotton  
swab between jacket opening and fitting. If cotton is wet,  
follow “Draining” instructions in the Periodic Maintenance  
section and then remove fitting. Put pipe dope or teflon tape  
on the threads and replace. Then follow Filling the Water  
Heater instructions in the Installing the New Water Heater  
section.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE (Continued)  
These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME® (1-800-469-4663)  
for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.  
Problem  
Cause  
Solution  
Improperly sealed, hot or cold supply connection,  
relief valve, drain valve, or thermostat threads.  
Leakage from other appliances or water lines.  
Condensation of flue products.  
Tighten threaded connections.  
WATER LEAKS  
Inspect other appliances near water heater.  
Refer to CONDENSATION.  
Thermal expansion in closed water system.  
Improperly seated valve.  
Install thermal expansion tank (DO NOT plug T&P valve).  
Check relief valve for proper operation  
(DO NOT plug T&P valve).  
LEAKING T&P VALVE  
SMELLY ODORS  
High sulfate or mineral content in water supply.  
Drain and flush heater thoroughly, then refill.  
Bacteria in water supply.  
Chlorinate or aerate water supply.  
Refer to LIGHTING INSTRUCTIONS.  
Turn on main gas shutoff valve.  
Adjust igniter tip.  
Gas control knob not positioned correctly.  
Main gas supply off.  
Igniter tip more than 1/8" from pilot hood.  
Thermocouple malfunction.  
Replace pilot assembly.  
Thermocouple TCO malfunction.  
Melted insulation on igniter wire or shorting  
of igniter wire.  
Replace pilot assembly.  
Contact Sears Service to determine cause.  
PILOT WILL NOT LIGHT  
High ambient room temperature.  
Contact Sears Service to determine cause.  
Wire disconnected from spark igniter.  
Broken electrode or electrical wire.  
Piezo Igniter generator fails to operate or  
malfunctions.  
Reconnect wire connector to spark igniter.  
Replace pilot assembly.  
Replace Piezo Igniter generator.  
Thermocouple TCO malfunction.  
High ambient room temperature.  
Replace pilot assembly.  
Contact a service agency to  
determine cause.  
BURNER WILL NOT  
STAY LIT  
Dirty or clogged air intake screen.  
Flame arrestor openings blocked.  
Clean and reinstall air intake screen.  
Contact Sears Service to  
determine cause.  
Defective Gas Control.  
Replace Gas Control.  
Dirty pilot burner.  
Clean pilot assembly.  
Dirty or clogged air intake screen.  
Thermocouple tip is not in contact with pilot flame.  
Thermocouple malfunction.  
Thermocouple TCO malfunction.  
Defective Gas Control.  
Clean and reinstall air intake screen.  
Insert thermocouple correctly.  
Replace pilot assembly.  
PILOT OUTAGE  
Replace pilot assembly.  
Replace Gas Control.  
Heater not lit or thermostat not on.  
Thermostat set too low.  
Refer to LIGHTING INSTRUCTIONS.  
Refer toTEMPERATURE REGULATION.  
Reduce hot water use.  
Heater undersized.  
NOT ENOUGH  
HOT WATER  
Low gas pressure.  
Contact your gas supplier.  
Incoming water is unusually cold.  
Leaking hot water pipes or fixtures.  
High temperature limit switch activated.  
Allow more time for heater to re-heat.  
Have plumber check and repair leaks.  
Contact Sears Service to  
determine cause.  
WATER TOO HOT  
Thermostat set too high.  
Refer toTEMPERATURE REGULATION.  
Refer to CONDENSATION.  
WATER HEATER SOUNDS  
Condensation dripping on burner.  
Sediment or calcium in bottom of heater tank.  
Clean sediment from tank. Refer to DRAINING  
instructions in Maintenance section of manual.  
No adjustment available. Contact Sears Service  
to determine cause.  
SIZZLING - RUMBLING  
SOOTING  
Improper combustion.  
Lack of supply air.  
Improperly installed vent piping.  
Downdraft.  
Contact Sears Service to determine cause.  
VENT GAS ODORS  
Poor combustion.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS ORDER LIST  
POWER MISER™ 6 GAS WATER HEATER  
MODEL NO’S  
153.336162  
153.336262  
153.336362  
30 Gallon Short  
40 Gallon Short  
30 Gallon  
3
BURNERASSEMBLY  
Model Numbers  
153.336262  
9003406  
9003889  
9003485  
9003385  
9003457 (#37)  
9003391  
9003405  
9000058  
9001584  
9003480  
9003445  
F145-1278  
9003500  
9003981  
9003398  
9003401  
184231-001  
23600  
9003719  
9003545  
9003410  
9003488  
9000071  
F145-1280  
9003414  
Key No. Part Description  
153.336162  
9003406  
9003888  
9003477  
9003385  
9003478 (#38)  
9003391  
9003405  
9000058  
9001584  
9003999  
9003445  
F145-1278  
9003500  
9003981  
9003400  
9003401  
184231-001  
23600  
153.336362  
9003406  
9003889  
9003442  
9003385  
9003443 (#36)  
9003390  
9003405  
9002402  
9001584  
9003969  
9000275  
F145-1278  
9003463  
9003981  
9003399  
9003401  
184231-001  
23600  
1
2
Air Intake Screen  
Anode Rod  
3
4
BurnerAssembly  
Burner Head**  
5
6
7
Burner Orifice**  
Burner Tube w/Rubber Boot**  
Draft Hood  
8
Drain Valve  
9
Drain Valve Washer  
Flue Baffle  
10  
11  
12  
13  
*14  
15  
16  
*17  
*18  
19  
20  
21  
22  
23  
24  
25  
Flue Restrictor  
Gas Control Valve  
Inlet Tube  
Inlet Tube Gasket  
Inner Door**  
Inner Door Gasket  
Instruction Manual  
Mag-Erad  
Nipple w/Heat Trap  
Outer Door  
9003719  
9003545  
9003410  
9003542  
9000071  
F145-1280  
9003414  
9003719  
9003545  
9003410  
9003542  
9000071  
F145-1280  
9003414  
Piezo Igniter w/Bracket  
PilotAssembly w/Grommet**  
T& P Relief Valve  
TemperatureAdjustment Knob  
ViewportAssembly  
* Not Shown. ** Includes Inner Door Gasket  
Now that you have purchased your gas water heater, should a need  
ever exist for repair parts or service, simply contact any Sears Service  
Center or call 1-800-4-MY-HOME® (1-800-469-4663). Be sure to provide  
all pertinent facts when you call or visit.  
MODELNUMBER  
SERIALNUMBER  
TYPE GAS - NATURALOR PROPANE (L.P.)  
PARTDESCRIPTION  
WHEN ORDERING REPAIR PARTS,ALWAYS GIVETHE FOLLOWING  
INFORMATION:  
THIS ISAREPAIR PARTS LIST, NOT APACKING LIST.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS ORDER LIST  
POWER MISER™ 6 GAS WATER HEATER  
MODEL NO’S  
153.336466  
40 Gallon  
153.336566  
50 Gallon  
3
BURNERASSEMBLY  
Model Numbers  
Key No. Part Description  
153.336466  
9003406  
9003972  
9003458  
9003385  
9003443 (#36)  
9003391  
9003405  
9002402  
9001584  
9003970  
9000275  
F145-1278  
9003463  
9003981  
9003400  
9003401  
184231-001  
23600  
153.336566  
9003406  
9003891  
9003467  
9003385  
9003443 (#36)  
9003389  
9003405  
9003482  
9001584  
9003989  
9000275  
F145-1278  
9003473  
9003981  
9003398  
9003401  
184231-001  
23600  
1
2
Air Intake Screen  
Anode Rod  
3
4
BurnerAssembly  
Burner Head**  
5
6
7
Burner Orifice**  
Burner Tube w/Rubber Boot**  
Draft Hood  
8
Drain Valve  
9
Drain Valve Washer  
Flue Baffle  
10  
11  
12  
13  
*14  
15  
16  
*17  
*18  
19  
20  
21  
22  
23  
24  
25  
Flue Restrictor  
Gas Control Valve  
Inlet Tube  
Inlet Tube gasket  
Inner Door**  
Inner Door Gasket  
Instruction Manual  
Mag-Erad  
Nipple w/Heat trap  
Outer Door  
9003719  
9003545  
9003410  
9003531  
9000071  
F145-1280  
9003414  
9003719  
9003545  
9003410  
9003488  
9000071  
F145-1280  
9003414  
Piezo Igniter w/Bracket  
PilotAssembly w/Grommet**  
T & P Relief Valve  
TemperatureAdjustment Knob  
Viewport Assembly  
* Not Shown. ** Includes Inner Door Gasket  
Now that you have purchased your gas water heater, should a need  
ever exist for repair parts or service, simply contact any Sears Service  
Center or call 1-800-4-MY-HOME® (1-800-469-4663). Be sure to provide  
all pertinent facts when you call or visit.  
MODELNUMBER  
SERIALNUMBER  
TYPE GAS - NATURALOR PROPANE (L.P.)  
PARTDESCRIPTION  
WHEN ORDERING REPAIR PARTS,ALWAYS GIVETHE FOLLOWING  
INFORMATION:  
THIS ISA REPAIR PARTS LIST, NOTAPACKING LIST.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS ORDER LIST  
POWER MISER™ 6 GAS WATER HEATER  
MODEL NO’S  
153.336762  
153.336862  
153.336962  
30 Gallon Propane (L.P.)  
40 Gallon Propane (L.P.)  
50 Gallon Propane (L.P.)  
3
BURNERASSEMBLY  
Model Numbers  
Key No. Part Description  
153.336762  
9003406  
9003889  
9003451  
9003422  
9003453 (#51)  
9003454  
9003405  
9002402  
9001584  
9003969  
9000275  
F145-1279  
9003463  
9003981  
9003399  
9003401  
184231-001  
23600  
153.336862  
9003406  
9003972  
9003460  
9003422  
9003453 (#51)  
9003392  
9003405  
9002402  
9001584  
9003970  
9000275  
F145-1279  
9003463  
9003981  
9003400  
9003401  
184231-001  
23600  
153.336962  
9003406  
9003891  
9003565  
9003385  
9003453 (#51)  
9003389  
9003405  
9003482  
9001584  
9003989  
9000275  
F145-1279  
9003473  
9003981  
9003398  
9003401  
184231-001  
23600  
1
2
Air Intake Screen  
Anode Rod  
3
4
BurnerAssembly  
Burner Head**  
5
6
7
Burner Orifice**  
Burner Tube w/Rubber Boot**  
Draft Hood  
8
Drain Valve  
9
Drain Valve Washer  
Flue Baffle  
10  
11  
12  
13  
*14  
15  
16  
*17  
*18  
19  
20  
21  
22  
23  
24  
25  
Flue Restrictor  
Gas Control Valve  
Inlet Tube  
Inlet Tube Gasket  
Inner Door**  
Inner Door Gasket  
Instruction Manual  
Mag-Erad  
Nipple w/Heat Trap  
Outer Door  
9003719  
9003545  
9003410  
9003455  
9000071  
F145-1280  
9003414  
9003719  
9003545  
9003410  
9003455  
9000071  
F145-1280  
9003414  
9003719  
9003545  
9003410  
9004021  
9000071  
F145-1280  
9003414  
Piezo Igniter w/Bracket  
PilotAssembly w/Grommet**  
T& P Relief Valve  
TemperatureAdjustment Knob  
ViewportAssembly  
* Not Shown. ** Includes Inner Door Gasket  
Now that you have purchased your gas water heater, should a need  
ever exist for repair parts or service, simply contact any Sears Service  
Center or call 1-800-4-MY-HOME® (1-800-469-4663). Be sure to provide  
all pertinent facts when you call or visit.  
MODELNUMBER  
SERIALNUMBER  
TYPE GAS - NATURALOR PROPANE (L.P.)  
PARTDESCRIPTION  
WHEN ORDERING REPAIR PARTS,ALWAYS GIVE THE FOLLOWING  
INFORMATION:  
THIS IS AREPAIR PARTS LIST, NOTAPACKING LIST.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 - YEAR LIMITED WARRANTY ON WATER HEATER  
For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the  
owner’s manual instructions and all local applicable plumbing codes, Sears will:  
1. Supply free water heater parts for those that are defective in material or workmanship.  
2. Supply a free water heater for one that develops a leak.  
For the second through sixth year from the purchase date, you must pay the labor cost for installation of parts or water heater.  
For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for two years.  
During the second year you must pay the labor cost for parts or water heater installation.  
1 - YEAR EXCLUSIVE KENMORE LABOR WARRANTY  
For the first year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for defective ones  
or a new water heater for one that develops a leak.  
WARRANTYSERVICE  
To obtain warranty service, call 1-800-4-MY-HOME® (1-800-469-4663).  
This warranty applies only while this product is in use in the United States.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
SEARS, ROEBUCK AND CO., Dept.817WA, Hoffman Estates, IL 60179  
The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Sears  
warrants the installation.  
A charge will be made on service calls due to poor or incomplete installation. These include:  
a.Adjusting thermostat  
c. Condensation  
b. Leaks in pipes or fittings  
MASTERPROTECTIONAGREEMENTS  
Power surge protection against electrical damage due to power  
fluctuations.  
Congratulations on making a smart purchase. Your new Kenmore®  
product is designed and manufactured for years of dependable operation.  
But like all products, it may require preventive maintenance or repair from  
time to time. That’s when having a Master Protection Agreement can  
save you money and aggravation.  
Rental reimbursement if repair of your covered product takes  
longer than promised.  
Once you purchase theAgreement, a simple phone call is all that it takes  
for you to schedule service. You can call anytime day or night, or  
schedule a service appointment on-line.  
Purchase a Master ProtectionAgreement now and protect yourself from  
unexpected hassle and expense.  
Sears has over 12,000 professional repair specialists, who have access  
to over 4.5 million quality parts and accessories. That’s the kind of  
professionalism you can count on to help prolong the life of your new  
purchase for years to come. Purchase your Master ProtectionAgreement  
today!  
The Master ProtectionAgreement also helps extend the life of your new  
product. Here’s what’s included in theAgreement:  
Expert Service by our 12,000 professional repair specialist.  
Unlimited service and no charge for parts and labor on all covered  
Some limitations and exclusions apply. For prices and additional  
information call 1-800-827-6655.  
repairs.  
“No-lemon” guarantee - replacement of your covered product if  
four or more product failures occur within twelve months.  
SEARS INSTALLATION SERVICE  
For Sears professional Installation of home appliances, garage door  
openers, water heaters, and other major home items, in the U.S.A., call  
1-800-4-MY-HOME®.  
Product replacement if your covered product can’t be fixed.  
Annual Preventive Maintenance Check at your request - no  
extra charge.  
Fast help by phone - phone support from a Sears technician on  
products requiring in-home repair, plus convenient repair scheduling.  
For in-home major brand repair service  
Call 24 hours a day, 7 days a week (U.S.A. and Canada)  
1-800-4-MY-HOME®  
(1-800-469-4663)  
The model number of your water heater is found on the model rating plate on the front of the water heater.  
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pyramid Car Audio Car Amplifier PB1281X User Guide
Radica Games Handheld Game System 71051 71027 7102B User Guide
Radio Shack Weather Radio 12 251 User Guide
Roadmaster GPS Receiver VRBT400 User Guide
Roberts Gorden Electric Heater CRV Series User Guide
SanDisk MP3 Player Rhapsody User Guide
Sanitaire Vacuum Cleaner SC886 E User Guide
Sanyo Battery Charger N 1200SCK User Guide
Seagate Computer Drive 4096 User Guide
Sears Refrigerator 53471 User Guide