Schneider Electric Outboard Motor 3BZ2 User Guide

Download from Www.Somanuals.com. All Manuals Search And Download.  
The world's first EOCR  
with built-in ZCT  
(bottom hole & terminal type)  
will save space, time and wiring through unique development design  
during installation.  
with compact size, possible to be applied to various panel size.  
the protection function added for high groud fault current.  
most suitable for low frequency circumstance (5Hz~, Inveter use)  
can cover wide range current through product innovation,  
so it leads to the decrease of customer's managing stocks and  
simplicity of replacement.  
Samwha EOCR has been developing the products only related to EOCR for  
around 30 years, since established and now challenging the conquering of world  
market with the real speciality for EOCR that other companies never have.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Applications  
Building  
Industrial facilities  
Petrochemical, electronic, glass, steel, semiconductor,  
chemical, medicine, cement, paint  
Office, commercial business, residence, school, hospital  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Control power  
Rated current  
24 VDC  
Over current : 0.5~80A (Definite)  
85~260 VAC/DC, 50/60 Hz  
GF current : 0.03A~10A  
5~200Hz Variable frequency  
measurement  
Composition by function  
Earth Fault  
Motor protection  
i3BZ, iFBZ (with Modbus RS-485)  
Thermal Overload  
3BZ2, FBZ2 (without Modbus RS-485)  
Over/under current  
Stall/Jam  
EF current  
Phase loss/lmbalance  
Contact contact  
A-Type  
95-96(b), 97-98(a) : OL  
57-58(a) : GR  
C-Type  
Network communication  
Modbus RS-485  
95-96(b), 97-98(a) : OL/GR  
07-08(a) : AL/UL/TO  
Public institutions  
Gas, water supply and drainage, airport, train, port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
EOCR-i3BZ / i3BZ2 Bottom hole type  
EOCR-iFBZ / iFBZ2 Bottom hole type  
EOCR-i3BZi / 3BZ2 Terminal type  
EOCR-iFBZ / iFBZ2 Terminal type  
General Features  
Earth fault detection by built-in ZCT  
Multifunctional motor protection for rated motor currents up to 80A (Definite Overcurrent protection) :  
Over Current, Under Current, Phase Loss, Phase Reversal, Stall, Jam, Current Imbalance, Earth Fault  
Thermal Inverse / Inverse overload protection up to 32Amps by integrated CTs.  
Real Time Processing / High Precision  
Ancillary Functions : Fail Safe, Alert(“C” Type Only), Accumulated Running Hour, 3 Fault records & limitation of auto-reset attempt.  
Communication : Modbus-RTU/RS-485(i3BZ/iFBZ only)  
Reinforced Monitoring Function : Real Time Monitoring up to 400M, 3 Phase Current Display, Pre-alarm & Cause of Trip indication.  
Load ratio indication of Load Current to over-current threshold.  
Support Single-phase and 3 Phase Motor  
For iFBZ / FBZ2, normal operation except display is guaranteed when PDM is disconnected  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Protection functions  
Item  
Operating Condition & Setting Range  
Load current(In) exceeds threshold(Is)  
Operation Time  
Definite(Def) : 0.2~30s Adjustable  
Over Current (oc)  
Setting Range : 0.5~80A(Def), 0.5~32A(Inv & th)  
Load current(In) less than threshold(uc) In <= uc  
uc should be less than oc Setting  
Inverse(Inv) & Thermal(th) : 1~30 Class  
Under Current (uc)  
Phase Loss (PL)  
Reverse Phase(rP)  
oFF, 1~30s Adjustable  
max imbalance is more than 85% among 3 phase current,  
Enable or disable : Selectable  
oFF, 0.5~5s Adjustable  
Within 0.15s  
Reversed phase sequence input on EOCR.  
Enable or disable : Selectable  
Active only in motor starting, In Stall threshold (Sc×OC).  
Setting Range : Adjustable  
Stall (Sc)  
Jam (JA)  
Immediately after D-Time elapsed  
0.2~10s Adjustable  
2~8 times of oc setting if Sc×OC doesnt exceed 250A  
Active only in motor running, In Jam threshold (JA×OC).  
Setting Range :  
1.5~8 times of oc setting if JA×OC doesnt exceed 250A  
Current unbalance threshold1~10s Adjustable.  
Setting Range : 10~50%  
Unbalance (ub)  
Earth Fault (EF)  
1~10s Adjustable  
Unbalance[%] = 100 × (Max phase current - Min phase current)/  
Max phase current  
EF current(Ie) exceeds threshold(Ies)  
0.1~10s Adjustable  
Setting Range : oFF, 0.03~10A  
Auxillary functions  
Password  
Secure configuration, available only with i3BZ/iFBZ  
Communication  
Fail Safe  
Serial network communication for monitoring of metering, status, and fault history  
Enable/Disable fail-safe operation of OL trip output  
Phase selection  
Total Running-Hour  
Running-Hour  
Fault History  
Select a Single-phase motor or 3-Phase motor  
Record of total running from installation which cannot be modified or cleared  
Accumulated running hour from preset point which can be cleared to zero, when motor stops  
Records for recent 3 faults each phase current which stored in a non-volatile memory  
Limitation of autoreset attempt Block auto-reset if the reset count exceeds the pre-set count within 30 minutes  
Communication function (Applicable to i3BZ/iFBZ)  
Item  
Setting  
Remark  
Protocol type  
Modbus RTU  
RS-485  
Communication type  
Baud rate  
1.2, 2.4, 4.8, 9.6, 19.2, 38.4 kbps  
Maximum length of the bus Maximum 1.2kM  
Type of trunk cable RS-485 Shielded Twist 2-Pair Cable  
Depend on the environment  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Specifications  
Model  
i3BZ/iFBZ, 3BZ2/FBZ2  
Over Current  
Rated Setting Range(A)  
Rated Setting Range(A)  
Definite TCC : 0.5~80A  
Inverse & th TCC : 0.5~32A  
*** CAUTION : Do not use any external CT  
0.5A ~ less than oc setting  
Definite(Def) / Inverse(Inv) / Thermal Inverse(th)  
0~200s  
Under Current  
*1)  
Operating Time Characteristics  
Time Setting  
Definite  
D-Time  
O-Time  
0.2~30s  
Inv & th (cLS)  
Auto-Reset  
1~30 Class  
0.5s~20min.  
Reset Mode  
Power Voltage  
Frequency  
Manual Reset (H-r) / Electric Reset (E-r)  
Control  
100~240VAC/DC(-15%, +10%, Free Voltage), 24VAC/DC(-15%, +10%) .  
50/60Hz  
Power Consumption  
Capacity  
Lower than 7VA  
Output  
Display  
3A/250VAC Resistive.  
Composition  
7 Segment LED  
Bar-graph  
NO/NC common output : OL , NO output : GR  
3 phase Amps, Cause of trip, Setting parameters indication.  
Load ratio (65 ~ 100%)  
*2)  
Communication  
Mounting  
Modbus-RTU/ RS-485  
Panel Mounting (i3BZ/3BZ2)  
Flush Mounting (iFBZ/FBZ2)  
Over DC500V 10MΪ  
Insulation  
Between Case & Circuit  
Dielectric Strength  
Between Case & Circuit  
Between Contacts  
Between Circuit  
: IEC61000-4-2  
: IEC61000-4-3  
: IEC61000-4-6  
: IEC61000-4-4  
: IEC61000-4-5  
: CISPR11  
2KV, 50/60Hz, I Min.  
1KV, 50/60Hz, I Min.  
2KV, 50/60Hz, 1 Min  
Electrostatic Discharge(ESD)  
Radiated Disturbance  
Conducted Disturbance  
EFT/Burst  
Level 3 : Air Discharge : ±8KV, Contact Discharge : ±6KV  
Level 3 : 10V/m, 80 ~ 1000MHz  
Level 3 : 10V, 0.15~80MHz  
Level 3 : ±2KV, 1 Min  
Surge  
Level 3 : 1.2×50, ±4KV(0 , 90 , 180 , 270  
Class A (Conducted and Radiated)  
-40~ +85℃  
)
Emission  
Environment  
Temperature  
Humidity  
Store  
Operation  
-20~ +60℃  
30~85% RH (Non-condensate)  
70W×74.5H×83.8D  
Dimension  
Weight  
Window Type  
Bottom Hole Type  
70W×56.3H×108.1D  
i3BZ : 295g, iFBZ : 280g  
3BZ2 : 292g, FBZ2 : 276g  
PDM : 125g, 3M cable : 120g  
*1) : 3BZ2/FBZ2 has no thermal inverse protection  
*2) : 3BZ2/FBZ2 has no MODBUS Communication  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Time-current characteristic curve  
1. Inverse characteristic (0.5~32A)  
2. Definite characteristic  
3. Inverse thermal characteristic (0.5~32A)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Over current and time setting tips  
Over current  
Setting tips in definite TCC mode  
1. Over current threshold (OC) :  
- Set the OC at the rating current of a motor. To protect machine together, it is recommended to set at 110~120% of the actual normal operating  
current.  
2. Starting delay time (D-time)  
- Set an expected start-up time to reach the normal current of load. If you do not know it, set to 15sec at first and start-up the motor to measure the  
time to reach the normal operation current by monitoring the displayed current and then set the time at 2 sec longer than the time measured. For  
a Y-D start, its better to set time 2 sec longer than the preset time of the Y- change timer.  
3. Operation time (O-time) : Set the trip delay time which activates and counts down under a fault condition.  
Configuration tips when Inverse or Thermal Inverse characteristic is necessary  
1. Overcurrent threshold (oc) :  
- This value is the basic current and from the point of 105% of oc, the inverse curve starts. Usually oc is set to the rated current of the motor.  
2. Starting delay time (D-time)  
- Usually this value is set to zero. With zero D-time and Inverse is selected, first the cold curve is applied until the load current drops down the oc  
value, and then the hot curve is applied.  
- But if the user wants fast trip with very high current during starting, set D-time other than zero. With non-zero D-time, the enabled STALL funtion  
detects very high current immediately after the D-time elapsed.  
- If the Inverse is selected, and D-time is non-zero, the Inverse function is blocked during starting, and the hot curve is applied after D-time elapsed.  
- If Thermal Inverse is selected, it detects overcurrent regardless of D-time. That is, thermal inverse is activated during motor starting as well as  
motor running.  
3. Operation time (O-time) :  
- When Inverse or Thermal Inverse is selected, O-time setting determines the trip class. nEOCR supports trip class from 1 to 30. Refer to the  
graphical representation of Inverse or Thermal Inverse to check trip time.  
Caution : Do not use any External CT  
Alert Operation Pattern (#3)  
Do use this function by OL/GR common output.  
Running Stage  
ALo Selection  
Higher than the preset  
Alert value  
Starting  
Normal Operation  
Trip  
Aux  
1 Sec  
◀▶  
Flicker
1 Sec  
◀▶  
Hold  
Fail-safe operation  
A1-A2 powered and  
under normal operation  
A1-A2 powered  
and Tripped  
Fail-Safe  
A1-A2 not powered  
ON  
OFF  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Front face  
7 segment LED display  
Phase indication  
LED  
LED  
Reset  
Ampere(A)  
Second(s)  
Phase indication  
L1/L2/L3  
Mode  
selection  
Bar graph  
65 70 75 80 85 90 95 100%  
Set/Store  
5 digit 7 segment LED display  
Power  
Communication  
OL NO Output  
GR NO Output  
3 phase currents (In) and the leakage current are displayed every 2 seconds in  
sequence.  
OL NC Output  
Bar graph  
7 segment LED display  
it shows the load factor to OC setting value by %  
% value = (running current/setting current) × 100%  
Min scale is 65%  
if the setting value is the rated motor current,  
it shows the load factor of the motor.  
Reset  
Current display  
Mode  
selection  
Shows the highest current among three phases for oc, Stall, Jam trips.  
Shows the lowest current among three phases for uc, Ub trips.  
Shows the lost phase for PL.  
Set / Store  
Shows the phase and the current during running.  
Amp : Ampere. LED is on when a current display.  
× 10 : Shows the unit changed to 10 times.  
Sec : Second. LED is on when a time display.  
Power  
Communication  
OL NO Output  
GR NO Output  
OL NC Output  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
3 phase digital ammeter function  
2sec  
L2 current display  
2sec  
L1 current display  
2sec  
Rotate  
2sec  
GF current  
L3 current display  
Blocking display rotation can be done by pressing the SET button once during running. whenever press the SET button,  
the each phase current displays by turns. A fixed phase current display can be done by this.  
Pressing the ESC button, it returns to the Auto current display rotation mode.  
Buttons and Setting Sequence  
Button  
Description  
Navigate menus by pressing UP/DN button.  
Select a parameter to change, then the parameter starts blinking.  
Modify a parameter value by pressing UP/DN button.  
Memorize the values in the relay by pressing SET button. blinking stops to  
show its stored.  
Pressing ESC button, it returns to the current display. Without pressing ESC  
button, it returns to the load current display in 50sec automatically.  
※Fault history check : Pressing the ESC button more than 5sec, it displays the latest fault cause and the fault  
current or fault phase. Continuing to press DN button, you can see the current of L1(R), L2(S), L3(T), (GR) in  
turn. Press the DN button again to check the previous fault continually. In the latest fault display, the 100% LED  
of bar graph lights on and two LEDs of 95%, 100% lights on for the second fault display, three LEDs of 90%,  
95%, 100% lights on for the oldest fault display. When you press the ECS button in this mode, it returns to the  
normal current display mode. The oldest fault record is over written when the number of fault to record exceeds  
three.  
Setting sequence  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Setting sequence and menu  
No.  
Menu  
Parameter  
Description  
Default  
Use password other than zero for secured configuration. This feature enables  
limitation of setting modification by unauthorized person. Zero value is used for  
disabling password checking.  
1
Password  
Ph:3Phmode for a 3 phase load, Ph:1Phmode for a 1 phase load should be  
selected. If you select the Ph:1Ph, RP, PL and Ub functions will be disabled  
and not displayed in the menu mode  
2
3
Selection of Phase  
TCC Selection  
Time-Current Characteristic(TCC) setting. dEis for Definite TCC, Inis for  
Inverse TCC, this for thermal inverse TCC. Refer to the time-current  
characteristic curve . If tcc=no, only overcurrent protection is disabled.  
Select 50 or 60 based on the system fundamental frequency.  
4
5
6
7
Frequency  
Fail Safe  
Selection of Fail Safe(No volt release) operation for overload trip output,  
OL. Refer to Fail-Safe Operation  
Reversed Phase  
detection  
Enable or disable reverse phase detection  
Threshold for Over Current protection which cannot be set below the  
under current threshold(uc).  
Over Current Threshold  
Motor Starting delay, OC, UC, Stall, Jam, Ub are blocked during starting but PL,  
RP, and thermal inverse are not blocked. For InTCC mode, the cold curve is  
applied during before dt is activated and the hot curve is applied after the dt  
expired.  
8
9
Start Delay Time  
(the fault duration of definite overcurrent protection.  
the trip class for inverse overcurrent protection(refer to TCC curve)  
(the class for thermal overload protection based on the thermal  
image by load current (refer to TCC curve).  
Over Current Duration  
Under Current  
Threshold  
Threshold for Under Current protection. The setting should be higher than  
no-load current of a motor. The current value cannot be set higher than OC.  
Fault duration for the Under Current Operation. If the setting of oFFin the uc”  
mode is selected, this menu is not displayed  
10  
11  
Under Current  
Duration  
Earth Fault  
(Ground Fault)  
Threshold  
Threshold for Earth Fault protection. The capacitance leakage current of the  
motor and cable should be taken into account for the setting.  
The threshold value corresponds to the primary current of ZCT.  
Earth Fault duration  
12  
13  
14  
15  
16  
Earth Fault Duration  
EF starting Delay  
Phase Loss  
TCC is always a definite characteristic for earth fault detection.  
Blocking time of Earth Fault detection during motor starting.  
oFF, 1~30s adjustable This timer is only active during motor starting.  
Enable or disable Phase Loss(Single Phasing) detection. If the Ph:1Phis  
selected , this menu is not displayed.  
Fault duration for Phase Loss Operation . The setting range is 0.5~5 sec.  
if PL:oFFis selected, this menu is not displayed  
Phase Loss Time  
Threshold for Current Unbalance operation. To disable the function, set to  
oFF, The setting range is 10~50%.  
17  
18  
Unbalance Threshold  
Unbalance factor (%) = (max phase-min phase) / Imax phase ×100%  
Unbalance fault duration for Current Unbalance operation.  
The setting range is 1~10 seconds.  
Unbalance fault  
duration  
Threshold for locked rotor detection during motor starting. The value is the  
multiples of the over current threshold(oc).  
19  
Stall threshold  
If the locked rotor condition is detected, the trip relay operates in 0.5s after  
the dtexpires.  
If dt=0, this function is disabled and not displayed in the menu.  
Threshold for locked rotor detection during motor running. The value is the  
multiples of the over current threshold (oc)  
20  
21  
Jam threshold  
Jam fault duration  
Jam Fault duration  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Setting sequence and menu  
No.  
Menu  
Parameter  
Description  
Default  
Threshold of Alert output, set by % of the over current threshold (oc). If the load  
current is higher than this value, alert output(07-08 contact) is energized  
according to the setting of ALo:XX.  
If the load current is detected, alert output(07-08 contact) is energized. The alert  
threshold is no meaning for this operation.  
Refer to the Alert Operation Pattern.  
If the load current is higher than the alert threshold, alert output(07-08 contact)  
repeats open for 1s and close for 1s (flickering), The flickering starts from the  
motor starting.  
22  
Alert*1)  
Refer to the Alert Operation Pattern.  
If the load current is higher than the alert threshold, alert output(07-08 contact) is  
closed (holding) and remains closed until the load current decrease under the  
alert threshold. The alert output is blocked during motor starting.  
Refer to the Alert Operation Pattern.  
If the accumulated running hour is more than the Running Hour threshold,  
the alert output repeats close for 1s and open for 1s.  
The alert output is used only for under current protection. If this mode is selected,  
a trip by an under current fault is signaled through alert output(07-08), instead of  
overload trip output(95-96 or 97-98).  
Fault reset by a power cycle or by pressing the ESC button.  
Fault reset only by pressing the ESC button.  
23  
Reset  
Fault reset by a auto-reset timer,  
Setting range of the timer : 0.5sec~20min.  
Also the fault can be reset by a power cycle or by ESC button.  
The maximum auto-reset number during 30 minutes in auto-reset mode.  
The auto-reset counter is stored in the non-volatile memory and is cleared by  
pressing ESC button when the counter reaches the limitation.  
To disable limitation, select oFF. Setting range : oFF~5 times.  
In this menu, toggle display, -trh-and the accumulated value, is activated.  
The accumulation starts from the installation and the user cannot clear the  
accumulated value.  
24  
25  
Reset Limitation  
Not  
adjustable  
Total Running Hour  
This display unit is 1 hour.  
In this menu, toggle display, --rh-and the accumulated value, is activated The  
user can clear the accumulated value by selecting the running hour threshold to  
rh:oFF. When motor stops  
Not  
adjustable  
26  
27  
Running Hour  
This display unit is 0.1 hour (6 minutes).  
By selecting ALo:to, the user can get the alert signal through alert output(07-08)  
when the accumulated value is more than the running hour threshold.  
Threshold for alert output when the user selects ALo:to. The unit is 10 hours  
and this menu is not displayed when the motor is starting or running.  
Setting range : 10~9990 hours, oFF  
Running Hour  
Threshold  
Modbus slave address.  
Range : 1 ~ 247.  
Setting for Communication speed  
Range : 1.2kbps, 2.4Kbps, 4.8Kbps, 9.6Kbps,19.2Kbps, 38.4Kbps .  
Parity setting  
Range : odd, even, non.  
28  
Communication*2)  
Duration for communication loss detection.  
Displays alarm when no new communication data is received for the duration.  
If oFFis selected, no monitoring for communication channel is activated.  
Setting range : 1~999 sec, oFF  
When this menu activated, OL trip signal and enabled EF trip signal is generated  
when (3s+ot) expires. The display shows Endwhen the test is done.  
By pressing ESC, returns to the load current display mode.  
This menu is not displayed when the motor is starting or running.  
Before (3s+ot) expires, pressing ESC or motor starting or running blocks the test  
trip and return to the load current display.  
No  
parameter  
29  
30  
Test Trip  
End  
No  
parameter  
This shows the end of test trip. Test result is stored in the fault record.  
*1) This menu is only available in “C” Type.  
*2) These are applied to i3BZ & iFBZ only.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Trip cause indication and fault records  
3 fault records including the trip cause and 3phase currents are stored in a non-volatile memory.  
Trip Indication  
Trip  
Indication  
Indication after trip with UP/ DN button pressing  
L1 LED on L2 LED on L3 LED on  
Trip Cause  
Contents of Indication  
Over current  
OC Trip caused by r-phase current  
Phase loss  
Reverse Phase  
Stall  
Phase Loss caused by r-phase lost  
Phase reversal trip  
Stall trip during motor starting  
caused by s-phase current  
Jam trip during motor running  
caused by r-phase current  
Jam  
Imbalance trip caused by t-phase  
current  
Imbalance  
Under current trip caused  
by s-phase current  
Under Current  
Earth Fault  
Limitation of auto-Reset  
Earth Fault(Earth leakage) trip with  
Earth Fault current indication  
In 30minutes, the number of  
For emergency restart, manual reset by pressing  
auto-reset exceeds the pre-set count ESC clears the reset counter to zero.  
Control terminals  
A type  
GR  
OL  
OL  
COMM  
A1 A2 57 58 95 96 97 98 V- D1 D0  
S
Modbus Communication  
Control Power  
OL NO Output  
OL NC Output  
GR NO Output  
C type  
AL / UL / TO  
OL / GR  
COMM  
A1 A2 07 08 95 96 97 98 V- D1 D0  
S
Control Power  
AL/UL/TO  
Modbus Communication  
OL/GR NO/NC Common Output  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Wiring Examples  
3 phase line Diagram  
3 phase line Diagram  
EOCR-i3BZ/iFBZ  
OL : b, GR : a  
EOCR-i3BZ/iFBZ  
OL : 1a 1b, GR : 1a  
Caution  
Caution  
1. Do not use any External CT  
1. Do not use any External CT  
2. Earth fault detection by built-in ZCT  
2. Earth fault detection by built-in ZCT  
3 phase line Diagram  
Single phase line Diagram  
EOCR-i3BZ/iFBZ  
OL : 1a 1b, GR : 1a  
EOCR-i3BZ/iFBZ  
OL : b, GR : a  
Caution  
1. Do not use any External CT  
2. Earth fault detection by built-in ZCT  
Caution  
1. Do not use any External CT  
2. Earth fault detection by built-in ZCT  
Single line Diagram  
Single line Diagram  
FROM : BUSDUCT  
FROM : BUSDUCT  
EOCR-iFBZ  
EOCR-FBZ2  
MCCF-A1-RF  
MCCF-B1-RF  
MCCF-A1-RF  
MCCF-B1-RF  
DM  
DM  
DM  
DM  
DM  
DM  
DM  
DM  
DM  
DM  
P.T×3  
380/110V  
P.T×3  
380/110V  
EOCR  
-iFBZ  
EOCR  
-iFBZ  
EOCR  
-iFBZ  
EOCR  
-iFBZ  
EOCR  
-iFBZ  
EOCR  
-FBZ2  
EOCR  
-FBZ2  
EOCR  
-FBZ2  
EOCR  
-FBZ2  
EOCR  
-FBZ2  
F
F
MODBUS 485  
MODBUS 485  
MODBUS 485  
MODBUS 485  
MODBUS 485  
MAIN  
MCCB  
MAIN  
MCCB  
DM  
DM  
C.T  
Y-  
Y-△  
Y-△  
C.T  
Y-△  
Y-△  
Y-△  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Dimensions  
3-12  
4.5  
82  
95  
108.1  
EOCR-i3BZ / 3BZ2 (Bottom Hole)  
EOCR-i3BZ / 3BZ2 (Teminal Type)  
EOCR-iFBZ / FBZ2 (Bottom Hole)  
EOCR-iFBZ / FBZ2 (Teminal Type)  
PANEL & DIN RAIL TYPE  
MOUNTING HOLE SIZE  
4.5  
21.4 21.4  
70  
6-M4  
45.3  
82  
95  
108.1  
PANEL & DIN RAIL TYPE  
MOUNTING HOLE SIZE  
3-12  
4.5  
82  
95  
108.1  
126.7  
PANEL & DIN RAIL TYPE  
MOUNTING HOLE SIZE  
4.5  
45.3  
6-M4  
21.4 21.4  
70  
82  
95  
108.1  
126.7  
PANEL & DIN RAIL TYPE  
MOUNTING HOLE SIZE  
13.4  
28.1  
72  
MOUNTING HOLE SIZE  
EOCR-PDM  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EOCR-i3BZ/iFBZ/3BZ2/FBZ2  
EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,  
EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT  
Order Code  
For nEOCR- order  
i
3
B
Z
-
WR A U H L  
i3BZ  
iFBZ  
Intelligent, panel mounting unit  
Intelligent, flush mounting unit  
Basic Unit  
3BZ2 Economic, panel mounting unit  
FBZ2 Economic, flush mounting unit  
Current Range  
Output relay  
WR  
0.5~80A  
OL : 95-96 (NC output), 97-98 (NO output)  
GR : 57-58 (NO output)  
A
OL/GR : 95-96 (NC output), 97-98 (NO output)  
AL/UL/TO : 07-08  
C
B
U
H
T
DC/AC 24V(-15%, +10%)  
AC/DC 100~240V (-15%, +10%)  
Through bottom-hole  
Control Voltage  
Wiring method  
Through screw-terminal  
Low frequency adaptation  
L
For low system frequency (10Hz~100Hz)  
For Cable order,  
C A B  
L
E
-
RJ45  
-
0
0
1
Connector Typeb  
RJ45  
00H  
Only support RJ45 connector  
0.5M  
001  
1M  
Cable Length  
01H  
1.5M  
002  
2M  
003  
3M  
Others  
Special order up to 400M  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Communication Guide  
Modbus network setting  
Communication setting value  
Please set the Modbus communication parameters by PCON or HMI for the communication.  
Slave address  
Baud rate  
Parity  
Communication loss timeout  
Slave address  
The EOCR has slave addresses from 1 to 247.  
The factory default setting is 1.  
Baud rate  
The Communication speed provided is like below.  
1.2kbps  
2.4kbps  
4.8kbps  
9.6kbps  
19.2kbps  
38.4kbps  
The factory default setting is 19.2kbps  
Parity setting  
Even  
Odd  
None  
The factory default setting is even. Please refer to the table for the stop bit setting.  
Parity setting  
Stop bit  
Even or Odd  
1
None  
2
Communication loss timeout  
It is the criteria to confirm the communication disconnection with a master like as PLC.  
EOCR judges it as a communication disconnection error, if there is no call from the master  
during a certain preset time.  
The time setting range is 1~999sec the factory default setting is OFF. The OFF means no  
communication error check. It is advised to set it at OFF, if there is no concern of  
communication disconnection or no needs of communication error check at ordinary times.  
RS485 bus connection  
RS485 standard allows several different characteristics.  
Polarization  
Line terminator  
Number of slaves  
Length of the bus  
There is a definition of Modbus presented in detail at the website of Modbus.org in 2002.  
Standard connection.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Communication Guide  
Standard connection  
The standard connection conforms to the Modbus specifications, sepecially 2 wire  
multidrop serial bus diagram, presented at the website of Modbus.org in 2002  
(Modbus_over_serial_line_V1.pdf, Nov.2002). Simple wiring diagram is like below.  
The characteristics is like below in case of a direct connection to the bus.  
Items  
Contents  
single, shielded, twisted pair cable.  
Min 3rd cable  
Type of trunk cable  
Maximum length of the bus  
1000m (3,2181 ft) (at 19.2kbps)  
32 stations (31 slaves)  
Maximum number of  
stations without repeater  
20m (66ft, at 1 tapoff)  
Maximum length of tapoffs  
Bus polarization  
40m (131ft, divided by tapoff no.  
in Multi-Junction Box)  
450 - 650Pullup resistor, 5V basis  
450 - 650Pulldown resistor,  
Recommend the polarization to Master at  
Common. There is no polarization at  
RS485 of EOCR .  
Line terminator  
120Resistor, + /- 5%  
YES (connect 1 protection ground minimum  
to the bus)  
Common polarity  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Communication Guide  
Bus connection through a SCA type junction box  
1. Master (PLC, PC or communication module)  
2. Modbus cable (It is different according to the master side or a master having polarization combined to the other part of Bus)  
3. Junction box  
4. Modbus cable  
5. Line terminators : 120- 0.25W  
Please use a cable with 2pair shieded twisted conductors for Interface protection.  
It is adviced to isolate the Modbus cable 30cm(11.8in) at least from a power cable.  
If necessary, intersect the Modbus cable to a power cable perpendicularly.  
Refer to the diagram in the left side for the line terminator wiring.  
2 wire MODBUS RJ45 connections  
Pin on RJ45  
Pin on nEOCR  
EIA/TIA 485 name  
4
5
8
D1  
D0  
V-  
B/B’  
A/A’  
C/C’  
Pin Scan be used for shield wire connection.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Head Office  
6th floor, Jeil Bldg., 94-46, Youngdeungpo-Dong 7Ka, Youngdeungpo-Ku, Seoul, Korea  
Tel. 82 2 3473 2340 / Fax 82 2 3473 1159  
Iksan Plant  
574, Yongie-dong, Iksan-shi, Junbuk, Korea  
Tel. 82 63 835 5033 / Fax 82 63 835 4175  
04/2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Rheem Water Heater Universal Gas User Guide
Roland Music Mixer M 16DX User Guide
Samsung Blu ray Player 1357B BD P1200 XAC User Guide
Samsung Home Theater System HT E550 User Guide
Samsung IP Phone DS 5000 User Guide
Sanus Systems Indoor Furnishings HTB4 User Guide
Sanyo Flat Panel Television LCD 26XR9DA User Guide
Sanyo Microwave Oven EMS 8500S User Guide
Sears Tiller 91729149 User Guide
Sears Washer 134542000 User Guide