INSTRUCTION MANUAL
COLOR CCD CAMERA
VCC-5774
VCC-5774M
About this manual
Before installing and using the camera, please read this
manual carefully. Be sure to keep it handy for later reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
Depending on the conditions of use, installation
and environment, please be sure to make the
appropriate settings and adjustments. If you
need help with installation and/or settings,
please consult your dealer.
CONTENTS
INFORMATION TO USER.............. 3
PRECAUTIONS .............................. 5
PARTS NAMES.............................. 7
MOUNTING THE LENS.................. 9
CONNECTIONS.............................. 11
FLANGE-BACK ADJUSTMENT ...... 13
SETTINGS ...................................... 14
TROUBLESHOOTING.................... 17
SPECIFICATIONS........................... 18
ACCESSORIES................................ 20
Download from Www.Somanuals.com. All Manuals Search And Download.
English 1
FEATURES
• Built-in interline transfer method 1/3" CCD,
approx. 410,000 picture elements
• Low smear, anti-blooming, low lag, no
burning and no geometric distortion using
the CCD solid state image device.
• 100% solid state components giving
excellent immunity to shock and vibration
• Not subject to interference from magnetic or
electrostatic fields
• VCC-5774 (AGC: ON)
High sensitivity, minimum required
illumination is 1.4 lux (F1.2)
VCC-5774M (AGC: OFF)
High sensitivity, minimum required
illumination is 7 lux (F1.2)
About VCC-5774M for a Casino
Designed to produce the best picture especially
under halogen light conditions with manual iris
lenses.
Design features:
Fixed Gain
Instead of AGC, Fixed Gain is adopted for pictures
with less video noise under low light conditions.
Automatic White Balance (AWB)
AWB is adjusted for best results under halogen
light (Color temperature: approx. 3000K)
conditions.
Note: Under fluorescent light or sun light
conditions (Approx. 5000K) a bluish
image may be produced.
• Horizontal resolution, more than 480 TV lines
• Equipped with connectors for AC 24 V and
DC 12 V power supply.
Gamma curve
Gamma Curve makes dark parts of the image
brighter. With Line Lock mode, noise might be
noticeable. In this case, switch to Internal Sync.
(Internal Sync is selected as default.)
Download from Www.Somanuals.com. All Manuals Search And Download.
2 English
INFORMATION TO USER
Safety Guard
For the customers in Canada
This Class B digital apparatus complies with
Canadian ICES-003.
THIS SYMBOL INDICATES THAT THERE
ARE IMPORTANT OPERATING AND
MAINTENANCE INSTRUCTIONS IN THE
LITERATURE ACCOMPANYING THIS
UNIT.
Pour la clientèle canadienne
Cet appareil numerique de la Classe B est
conforme a la norme NMB-003 du Canada.
WARNING:
TO PREVENT THE RISK OF FIRE OR
ELECTRIC SHOCK , DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
This installation should be made by a qualified
service person and should conform to all local
codes.
Download from Www.Somanuals.com. All Manuals Search And Download.
English 3
INFORMATION TO USER
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Sanyo may void the user’s authority to
operate this camera.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 English
PRECAUTIONS
In case of problem
Be careful when handling the unit
Do not use the camera if smoke or a strange odour
comes from the unit, or if it seems not to function
correctly. Disconnect the power cord immediately,
and consult your dealer (or a Sanyo Authorized
Service Centre).
To prevent damages, do not drop the camera or
subject it to strong shock or vibration.
Install away from electric or magnetic
fields
If installed close to a TV, radio transmitter, magnet,
electric motor, transformer, audio speakers the
magnetic field they generate will distort the image.
Do not open or modify
Do not open the cabinet, as it may be dangerous
and cause damage to the unit. For internal settings
and repairs, consult your dealer (or a Sanyo
Authorized Service Centre).
Protect from humidity and dust
To prevent damages to the camera, do not install it
where there is greasy smoke or steam, where the
dampness may get too high, or where there is a lot
of dust.
Do not put objects inside the unit
Make sure that no metal objects or flammable
substance get inside the camera. If used with a
foreign object inside, it could cause a fire,
short-circuits or damages.
If water or a liquid gets inside the camera, disconnect
the power cord immediately, and consult your dealer
(or a Sanyo Authorized Service Centre). Be careful to
protect the camera from rain, sea water, etc.
Download from Www.Somanuals.com. All Manuals Search And Download.
English 5
PRECAUTIONS
Protect from high temperatures
Cleaning
Do not install close to stoves, or other heat
generating devices, such as spotlights, etc., or
where it could be subject to direct sunlight, as that
could cause deformation, discoloration or other
damages.
Be careful when installing close to the ceiling, in a
kitchen or boiler room, as the temperature may
raise to high levels.
•
•
Dirt can be removed from the cabinet by
wiping it with a soft cloth. To remove stains,
wipe with a soft cloth moistened with a soft
detergent solution and wrung dry, then wipe
dry with dry soft cloth.
Do not use benzine, thinner or other chemical
product on the cabinet, as that may cause
deformation and paint peeling. Before using a
chemical cloth, make sure to read all
accompanying instructions. Make sure that no
plastic or rubber material comes in contact with
the cabinet for a long period of time, as that
may cause damage or paint peeling.
Install where the temperature range will stay
between –10˚C and 50˚C.
(no condensation)
Download from Www.Somanuals.com. All Manuals Search And Download.
6 English
PARTS NAMES
1Camera mounting screw hole
2
3
CAUTION:
When installing the camera, select a location that can support
the total weight of the camera and accessories.
2Electronic iris function switch (EI OFF/EI ON)
1
3Sync switch (INT/L-L)
INT (Internal sync) position
L-L (Line lock) position
4
4Line phase adjustment volume (LINE PHASE)
5Lens iris level volume (LEVEL)
6Lens iris output connector (LENS)
This 4-pin connector is used to send the DC control signal and power supply to
an auto-iris type lens.
5
1
6
1
3
2
4
Download from Www.Somanuals.com. All Manuals Search And Download.
English 7
PARTS NAMES
8
7Flange-back lock screw
8CS mount ring
9Lens mount cap
The cap is installed to protect the lens mount section.
Remove the lens mount cap before installing a lens.
7
FVideo output connector (VIDEO OUT: BNC type)
Connect this connector to a device such as a VCR or monitor with a
VIDEO IN connector.
9
7
G24 V AC or 12 V DC input terminal
(24 V AC, 12 V DC, GND) … See page 11
G
F
Download from Www.Somanuals.com. All Manuals Search And Download.
8 English
MOUNTING THE LENS
Please use a DC type auto-iris lens (sold separately).
Checking the lens mount
Do not use lense with a length L more than 5 mm. If not, that may
damage the camera and prevent proper installation.
L
1 Remove the lens mount cap from the camera.
1
2 Install the auto-iris lens.
CS mount type lens
C mount
type lens
Carefully align the lens mount with the camera opening, then turn the lens
slowly to install it.
C mount type lens
Install the supplied C-mount adaptor on the lens mount, then carefully
align the lens mount with the camera opening and turn the lens slowly to
install it.
3 Connect the lens plug to the lens iris output connector (LENS) on
the side of the camera.
The plug shape may not correspond to the terminal on the camera. In such
a case, remove the original plug and using a soldering iron, connect the
supplied lens iris plug according to the diagram. (Refer to page 10.)
MOUNTING THE LENS
Rewiring the lens cable in the lens iris plug
1
1 Prepare the lens cable.
Cut the cable at the plug, then remove approx. 8 mm of the cable sheath and
strip about 2 mm from each wire.
2
2 Install the lens iris plug.
Solder the cable to the pins following the correct pin layout (refer to the
table and illustrations), then close the plug cover.
Compatible auto-iris lenses (1/3 inch COSMICAR DC type lens)
• Standard angle, f= 8 mm (TS812E Equivalent)
• Wide angle, f= 4 mm (TS412E Equivalent)
• Ultra-wide angle, f= 2.8 mm (TS212E Equivalent)
Pin layout
1
2
3
4
Brake coil (–)
Brake coil (+)
Drive coil (+)
Drive coil (–)
CONNECTIONS
Basic connection for monitoring or recording
Note:
The polarities for the 24 V AC and
the 12 V DC input connectors are
indicated on the rating label found
on the unit back panel.
AC 24 V ~ ~
GND
DC 12 V + –
Push to insert the cable.
(Video signal connections)
: VIDEO IN
AC 24 V connection
: VIDEO OUT
DC 12 V connection
DC12V
+
–
+
–
Fig. 1
Fig. 2
Download from Www.Somanuals.com. All Manuals Search And Download.
English 11
CONNECTIONS
The peripheral devices (VCR, monitor, lens,
etc.) and cables are sold separately.
3 Insert the plug of this power supply into
a wall outlet.
1 Make the video signal connection
between the camera and the monitor or
timelapse VCR.
Adjust the picture on the monitor using the
Brightness and Contrast controls.
Coaxial cable type and maximum length
2 Power supply choices
• When using an AC 24 V power supply (UL
listed class 2 power supply), make the
connections as indicated in Fig. 1.
• Cable type RG-59U (3C-2V), 250 m
maximum.
• Cable type RG-6U (5C-2V), 500 m maximum.
• Cable type RG-11U (7C-2V), 600 m
maximum.
• When using a DC 12 V power supply,
make the connections as indicated in Fig. 2.
Note: Use CCTV/Video-grade coaxial cable.
CAUTION:
• To prevent camera and/or power supply
failure, pay close attention to polarity
when making the connections.
• To prevent fire hazard any UL listed wire
rated VW-1, should be used for the 24 V
AC cable input terminal.
Download from Www.Somanuals.com. All Manuals Search And Download.
12 English
FLANGE-BACK ADJUSTMENT
CS mount
ring
If the pick-up surface is not correctly positioned with relation to the lens
focal point, the picture will be out of focus (in particular when using
auto-iris power zoom lenses, sold separately). If that is the case,
adjust the flange-back position as described below.
1 Before installing the lens, check that the two flange-back lock screws
have been tightened.
If the flange-back lock screws are loose, the CS mount ring will not
be secured and it will not be possible to adjust the flange-back.
Flange-back lock
screw
2 Fully install the lens, then loosen the two flange-back lock screws.
3 Set the zoom lens to the maximum telephoto position (TELE), then set
the focus using the focus ring on the lens.
4 Set the zoom lens to the maximum wide angle position (WIDE), then
set the focus by turning the CS mount ring.
5 Repeat steps 3 and 4 until the image stays in focus when changing
from a telephoto shot to a wide angle shot. When the setting is
complete, tighten the flange-back lock screws.
Download from Www.Somanuals.com. All Manuals Search And Download.
English 13
SETTINGS
Line phase adjustment
When using a camera switcher to connect 2
cameras or more to one monitor, there may be
a vertical roll of the images when switched. In
such a case, set as described below.
1 Set the Sync switch to the L-L position.
(Monitor)
2 Switch the display on the monitor from
camera 1 to camera 2.
Adjust the LINE PHASE volume on camera 2
until the vertical roll of the image stops.
If more than two cameras are used, please
repeat this procedure for all the cameras.
EI OFF
INT
EI ON
L-L
CAUTION:
LINE
PHASE
If the vertical roll cannot be corrected by setting
the LINE PHASE volume on camera 2, try
setting the LINE PHASE volume on camera 1.
If it still cannot be corrected, please check that
the polarity of the power cords of all connected
devices is correct.
Download from Www.Somanuals.com. All Manuals Search And Download.
14 English
SETTINGS
Lens iris adjustment
If using a DC type auto-iris lens, you will need to
set the LEVEL volume when shooting in the
conditions described below.
Counterclockwise: To decrease the brightness
Clockwise: To increase the brightness
• If shooting simultaneously in a dark room
and through a bright window.
• If the subject background is extremely bright
or dark.
LEVEL
• If the brightness of the picture on the
monitor is not correct.
Download from Www.Somanuals.com. All Manuals Search And Download.
English 15
SETTINGS
• If conditions are outside the electronic iris
operation range or more than the maximum
brightness, it will cause saturation of the
CCD. In that case, use a auto iris lens.
EI (Electronic iris) function setting
Under normal conditions, set the EI switch to
the EI OFF position and use an auto-iris lens.
However, if you have a manual lens or fixed iris
lens, set the lens aperture to the shortest F stop
and set the EI switch to the EI ON position.
Note:
EI OFF
INT
EI ON
L-L
Please refer to the specifications for dynamic
range of the electronic iris.
CAUTION:
• The electronic iris is suitable for normal
indoor use. When the EI switch is set to the
EI ON position, do not use an auto-iris lens.
• If used under fluorescent light, the image
may flicker. In such a case, change to
incandescent lighting or set the EI switch to
the EI OFF position and use an auto-iris lens.
• When shooting bright subjects, pay
attention to the light angle in order to avoid
or minimize the smear phenomenon effect.
Download from Www.Somanuals.com. All Manuals Search And Download.
16 English
TROUBLESHOOTING
Before taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still
does not perform correctly, please consult your dealer or a Sanyo Authorized Service Centre.
No picture on the monitor screen
•
•
•
•
•
Is the power turned on to all connected devices? Is the voltage correct?
Are all the signal connecting cables correctly connected?
Is the lighting sufficient?
Has the lens cap been removed?
Is the iris control correctly set?
The picture is not clear
•
•
•
•
Is the monitor correctly adjusted?
Is the flange-back position correctly set?
Is the lens focus correctly adjusted?
Are the lens surfaces clean?
If there is dust or finger prints on the lens, the image quality will deteriorate. To clean the lens use a
soft cloth or a commercially available lens cleaning set.
SERVICE
This camera is a precision instruments and if treated with care, will provide years of satisfactory
performance. However, in the event of a problem, the owner is advised not to attempt to make repairs or
open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized Service Centre.
Download from Www.Somanuals.com. All Manuals Search And Download.
English 17
SPECIFICATIONS
Scanning system: NTSC standard TV system
Electronic iris range: VCC-5774 only
1.4 lux to 70,000 lux (F 1.2, lens)
2.0 lux to 100,000 lux (F 1.4, lens)
(525 TV lines, 30 frames/sec.)
Interlace: 2:1 interlace
Flange-back: 12.5 mm 0.5 mm
White balance: ATW
Image device: 1/3 inch solid state image device CCD
Picture elements: 816 (H) x 494 (V)
Effective picture elements: 771 (H) x 492 (V)
Lens mount: CS mount
Environmental conditions:
Synchronizing system: Manual internal sync/
Temperature: –10˚C ~ +50˚C
Humidity: less than 90% (no condensation)
Line lock switching
Resolution: 480 TV lines horizontally,
Power supply: 24 V AC or 12 V DC
350 TV lines vertically
Power consumption:
Video output level: 1.0 Vp-p/75 ohms, composite
24 V AC, 60 Hz: 3.2 W (with auto-iris lens)
Video S/N ratio: More than 48 dB
2.5 W (without auto-iris lens)
12 – 15 V DC: 4.0 W (with auto-iris lens)
2.7 W (without auto-iris lens)
Minimum required illumination
(incandescent lighting):
AGC ON: Approx. 1.4 lux with a F 1.2 lens
(VCC-5774)
Weight: Approx. 160 g (without lens)
AGC OFF: Approx. 7 lux with a F 1.2 lens
(VCC-5774M)
Backlight compensation: ON condition only
Electronic iris function: Manual ON/OFF switching
Download from Www.Somanuals.com. All Manuals Search And Download.
18 English
SPECIFICATIONS
Dimensions: mm
51
63
(1)
68
Features and specifications are subject to change without prior notice or obligations.
Download from Www.Somanuals.com. All Manuals Search And Download.
English 19
ACCESSORIES
1
2
1C mount adaptor (5 mm) ........................1 pc.
The C mount adaptor must be used to be
able to install a C mount lens on the camera.
2Lens iris plug (4-pin).................................1 pc.
Download from Www.Somanuals.com. All Manuals Search And Download.
20 English
|